| 1 |
IS 398 : Part 4 (1994) |
Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Freedom from Defects) |
- |
100 |
|
For 22, 34, 55, 80,100 Rs. 10,000/- each 125, 148, 173, 200 525, 570, 604, 642, 695,767 sq.mm Rs. 15,500/- each |
| 7.1 Table-1(Dimensional measurement of wires) |
- |
500 |
|
- |
| 7.2.2 Table-2, Table-4(Calculated resistance of Stranded Conductor) |
- |
500 |
|
- |
| 8.1(Joints in wires-Conductors Containing Seven Wires) |
- |
100 |
|
- |
| 8.2(Joints in wires-Conductors Containing More Than Seven Wires) |
- |
100 |
|
- |
| 9.1(Stranding) |
- |
200 |
|
- |
| 9.2 Table 3(Lay Ratio of stranded conductors) |
- |
100 |
|
- |
| 9.3(Direction of Lay) |
- |
200 |
|
- |
| 9.4(Multiple layers of wires) |
- |
400 |
|
- |
| 11(Packing and Marking) |
- |
100 |
|
- |
| 12.2 Table 1(Breaking Load Test- Before Stranding) |
- |
500 |
|
- |
| 12.2 Table 1(Breaking Load Test- After Stranding) |
- |
500 |
|
- |
| 12.3 Table 1(Elongation Test- Before Stranding) |
- |
500 |
|
- |
| 12.3 Table 1(Elongation Test- After Stranding) |
- |
500 |
|
- |
| 12.4 Table 1(Resistance of Aluminium wire) |
- |
200 |
|
- |
| 9.2(Lay Ratio 24 wire layer) |
- |
200 |
|
- |
| 9.2(Lay Ratio 18 wire layer) |
- |
500 |
|
- |
| 9.2(Lay Ratio 12 wire layer) |
- |
300 |
|
- |
| 9.2(Lay Ratio 3/6 wire layer) |
- |
300 |
|
- |
| 7.2.1(Sizes) |
- |
200 |
|
- |
| Cl-7.2 (7.2.1, 7.2.2), Table-2(Stranding and Wire Dia) |
- |
500 |
|
- |
| Cl- 7.2 (7.2.1, 7.2.2), Table-2(Approx Overall Dia) |
- |
500 |
|
- |
| Cl. 7.2 (7.2.1, 7.2.2), Table 2(Approx Mass) |
- |
500 |
|
- |
| Cl- 7.2 (7.2.1, 7.2.2), Table-2(Calculated Maximum Resistance at 20°C) |
- |
500 |
|
- |
| Cl- 7.2 (7.2.1, 7.2.2), Table-2(Approx Calculated Breaking Load) |
- |
500 |
|
- |
| 6.1(Freedom from Defects) |
- |
0 |
|
- |
| 7.1 Table-1(Dimensional measurement of wires) |
- |
0 |
|
- |
| 7.2.2 Table-2, Table-4(Calculated resistance of Stranded Conductor) |
- |
0 |
|
- |
| 8.1(Joints in wires-Conductors Containing Seven Wires) |
- |
0 |
|
- |
| 8.2(Joints in wires-Conductors Containing More Than Seven Wires) |
- |
0 |
|
- |
| 9.1(Stranding) |
- |
0 |
|
- |
| 9.2 Table 3(Lay Ratio of stranded conductors) |
- |
0 |
|
- |
| 9.3(Direction of Lay) |
- |
0 |
|
- |
| 9.4(Multiple layers of wires) |
- |
0 |
|
- |
| 11(Packing and Marking) |
- |
0 |
|
- |
| 12.2 Table 1(Breaking Load Test- Before Stranding) |
- |
0 |
|
- |
| 12.2 Table 1(Breaking Load Test- After Stranding) |
- |
0 |
|
- |
| 12.3 Table 1(Elongation Test- Before Stranding) |
- |
0 |
|
- |
| 12.3 Table 1(Elongation Test- After Stranding) |
- |
0 |
|
- |
| 12.4 Table 1(Resistance of Aluminium wire) |
- |
0 |
|
- |
| 9.2(Lay Ratio 24 wire layer) |
- |
0 |
|
- |
| 9.2(Lay Ratio 18 wire layer) |
- |
0 |
|
- |
| 9.2(Lay Ratio 12 wire layer) |
- |
0 |
|
- |
| 9.2(Lay Ratio 3/6 wire layer) |
- |
0 |
|
- |
| 7.2.1(Sizes) |
- |
0 |
|
- |
| Cl-7.2 (7.2.1, 7.2.2), Table-2(Stranding and Wire Dia) |
- |
0 |
|
- |
| Cl- 7.2 (7.2.1, 7.2.2), Table-2(Approx Overall Dia) |
- |
0 |
|
- |
| Cl. 7.2 (7.2.1, 7.2.2), Table 2(Approx Mass) |
- |
0 |
|
- |
| Cl- 7.2 (7.2.1, 7.2.2), Table-2(Calculated Maximum Resistance at 20°C) |
- |
0 |
|
- |
| Cl- 7.2 (7.2.1, 7.2.2), Table-2(Approx Calculated Breaking Load) |
- |
0 |
|
- |
| 6.1(Freedom from Defects) |
- |
0 |
|
- |
| 7.1 Table-1(Dimensional measurement of wires) |
- |
0 |
|
- |
| 7.2.2 Table-2, Table-4(Calculated resistance of Stranded Conductor) |
- |
0 |
|
- |
| 8.1(Joints in wires-Conductors Containing Seven Wires) |
- |
0 |
|
- |
| 8.2(Joints in wires-Conductors Containing More Than Seven Wires) |
- |
0 |
|
- |
| 9.1(Stranding) |
- |
0 |
|
- |
| 9.2 Table 3(Lay Ratio of stranded conductors) |
- |
0 |
|
- |
| 9.3(Direction of Lay) |
- |
0 |
|
- |
| 9.4(Multiple layers of wires) |
- |
0 |
|
- |
| 11(Packing and Marking) |
- |
0 |
|
- |
| 12.2 Table 1(Breaking Load Test- Before Stranding) |
- |
0 |
|
- |
| 12.2 Table 1(Breaking Load Test- After Stranding) |
- |
0 |
|
- |
| 12.3 Table 1(Elongation Test- Before Stranding) |
- |
0 |
|
- |
| 12.3 Table 1(Elongation Test- After Stranding) |
- |
0 |
|
- |
| 12.4 Table 1(Resistance of Aluminium wire) |
- |
0 |
|
- |
| 9.2(Lay Ratio 24 wire layer) |
- |
0 |
|
- |
| 9.2(Lay Ratio 18 wire layer) |
- |
0 |
|
- |
| 9.2(Lay Ratio 12 wire layer) |
- |
0 |
|
- |
| 9.2(Lay Ratio 3/6 wire layer) |
- |
0 |
|
- |
| 7.2.1(Sizes) |
- |
0 |
|
- |
| Cl-7.2 (7.2.1, 7.2.2), Table-2(Stranding and Wire Dia) |
- |
0 |
|
- |
| Cl- 7.2 (7.2.1, 7.2.2), Table-2(Approx Overall Dia) |
- |
0 |
|
- |
| Cl. 7.2 (7.2.1, 7.2.2), Table 2(Approx Mass) |
- |
0 |
|
- |
| Cl- 7.2 (7.2.1, 7.2.2), Table-2(Calculated Maximum Resistance at 20°C) |
- |
0 |
|
- |
| Cl- 7.2 (7.2.1, 7.2.2), Table-2(Approx Calculated Breaking Load) |
- |
0 |
|
- |
|
03 Oct, 2027 |
- Incuded w.e.f. 14.10.2025 |
| 2 |
IS 3854 (2023) |
Switches for Domestic and Similar Purposes - Specification (Third Revision) |
UP TO AND INCLUDING 32A |
19800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(General Requirements) |
- |
20 |
|
- |
| Cl-5(General notes on tests) |
- |
20 |
|
- |
| Cl-6(Rating) |
- |
50 |
|
- |
| Cl-7(Classification) |
- |
50 |
|
- |
| Cl-8(Marking) |
- |
200 |
|
- |
| Cl-9(Checking of dimensions) |
- |
200 |
|
- |
| Cl-10.1, 10.2(Prevention of Access to Live Parts) |
- |
300 |
|
- |
| Cl-10.3(Requirements for Accessible Metal Parts) |
- |
150 |
|
- |
| Cl-10.4(Requirements for Insulation of the Mechanism) |
- |
250 |
|
- |
| Cl. 10.5(Requirements for Insulation of the Mechanism with Respect to the Surrounding Environment) |
- |
250 |
|
- |
| Cl-10.6(Requirements for Switches Operated Indirectly) |
- |
250 |
|
- |
| Cl-10.7(Requirements for Switches with Replaceable Pull Cord) |
- |
250 |
|
- |
| Cl-11(Provision for earthing) |
- |
300 |
|
- |
| Cl-12(Terminals) |
- |
200 |
|
- |
| Cl-13(Constructional requirements) |
- |
200 |
|
- |
| Cl-14(Mechanism) |
- |
250 |
|
- |
| Cl-15.1(Resistance to Ageing) |
- |
500 |
|
- |
| Cl-15.3(Resistance to Humidity) |
- |
1000 |
|
- |
| Cl-16.1(General) |
- |
200 |
|
- |
| Cl-16.2(Test for Measuring the Insulation Resistance) |
- |
150 |
|
- |
| Cl-16.3(Electric Strength Test) |
- |
1000 |
|
- |
| Cl-17(Temperature rise) |
- |
500 |
|
- |
| Cl-18(Making and breaking capacity) |
- |
2000 |
|
- |
| Cl-19(Normal operation) |
- |
2000 |
|
- |
| Cl-20(Mechanical strength) |
- |
200 |
|
- |
| Cl-21(Resistance to heat) |
- |
1000 |
|
- |
| Cl-22(Screws, current carrying parts and connections) |
- |
200 |
|
- |
| Cl-23(Creepage distances, clearances and distance through sealing compound) |
- |
250 |
|
- |
| Cl-24.1(Resistance to abnormal heat and fire) |
- |
250 |
|
- |
| Cl-24.2(Resistance to tracking) |
- |
250 |
|
- |
| Cl-25(Resistance to rusting) |
- |
250 |
|
- |
| 19.1(Test for Switches Intended for Inductive Loads) |
- |
500 |
|
- |
| 19.2(Test for Switches Intended for Externally Ballasted Lamp Loads) |
- |
500 |
|
- |
| 19.3(Test for Switches Intended for Self-ballasted Lamp Loads) |
- |
3000 |
|
- |
| 13.5(Attachment of knobs) |
- |
200 |
|
- |
| 12.3.11(Table 11)(Test Current for the Verification of Electrical and Thermal Stresses in Normal Use of Screwless Terminals) |
- |
250 |
|
- |
| 12.3.12(Table 13)(Deflection Test Forces) |
- |
230 |
|
- |
| Cl-4(General Requirements) |
- |
0 |
|
- |
| Cl-5(General notes on tests) |
- |
0 |
|
- |
| Cl-6(Rating) |
- |
0 |
|
- |
| Cl-7(Classification) |
- |
0 |
|
- |
| Cl-8(Marking) |
- |
0 |
|
- |
| Cl-9(Checking of dimensions) |
- |
0 |
|
- |
| Cl-10.1, 10.2(Prevention of Access to Live Parts) |
- |
0 |
|
- |
| Cl-10.3(Requirements for Accessible Metal Parts) |
- |
0 |
|
- |
| Cl-10.4(Requirements for Insulation of the Mechanism) |
- |
0 |
|
- |
| Cl. 10.5(Requirements for Insulation of the Mechanism with Respect to the Surrounding Environment) |
- |
0 |
|
- |
| Cl-10.6(Requirements for Switches Operated Indirectly) |
- |
0 |
|
- |
| Cl-10.7(Requirements for Switches with Replaceable Pull Cord) |
- |
0 |
|
- |
| Cl-11(Provision for earthing) |
- |
0 |
|
- |
| Cl-12(Terminals) |
- |
0 |
|
- |
| Cl-13(Constructional requirements) |
- |
0 |
|
- |
| Cl-14(Mechanism) |
- |
0 |
|
- |
| Cl-15.1(Resistance to Ageing) |
- |
0 |
|
- |
| Cl-15.3(Resistance to Humidity) |
- |
0 |
|
- |
| Cl-16.1(General) |
- |
0 |
|
- |
| Cl-16.2(Test for Measuring the Insulation Resistance) |
- |
0 |
|
- |
| Cl-16.3(Electric Strength Test) |
- |
0 |
|
- |
| Cl-17(Temperature rise) |
- |
0 |
|
- |
| Cl-18(Making and breaking capacity) |
- |
0 |
|
- |
| Cl-19(Normal operation) |
- |
0 |
|
- |
| Cl-20(Mechanical strength) |
- |
0 |
|
- |
| Cl-21(Resistance to heat) |
- |
0 |
|
- |
| Cl-22(Screws, current carrying parts and connections) |
- |
0 |
|
- |
| Cl-23(Creepage distances, clearances and distance through sealing compound) |
- |
0 |
|
- |
| Cl-24.1(Resistance to abnormal heat and fire) |
- |
0 |
|
- |
| Cl-24.2(Resistance to tracking) |
- |
0 |
|
- |
| Cl-25(Resistance to rusting) |
- |
0 |
|
- |
| 19.1(Test for Switches Intended for Inductive Loads) |
- |
0 |
|
- |
| 19.2(Test for Switches Intended for Externally Ballasted Lamp Loads) |
- |
0 |
|
- |
| 19.3(Test for Switches Intended for Self-ballasted Lamp Loads) |
- |
0 |
|
- |
| 12.3.11(Table 11)(Test Current for the Verification of Electrical and Thermal Stresses in Normal Use of Screwless Terminals) |
- |
0 |
|
- |
| 12.3.12(Table 13)(Deflection Test Forces) |
- |
0 |
|
- |
| 13.5(Attachment of knobs) |
- |
0 |
|
- |
|
03 Oct, 2027 |
- Included w.e.f 10.10.2025
Exclusion: Cl-15.2 (Protection Provided by Enclosures of Switches) |
| 3 |
IS 302 : Part 2 : Sec 202 (1992) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 202 electric stoves |
- |
14500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
200 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.101(Marking) |
- |
0 |
|
- |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
500 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
1000 |
|
- |
| 11(Heating, IS 302-1) |
- |
1000 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 12(Operation under overload conditions of appliances with heating elements, IS 302-2-202: 1992) |
- |
500 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
1000 |
|
- |
| 15.3(Moisture Resistance, IS 302-1) |
- |
500 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
- |
| 19.2(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
| 19.2(Abnormal Operation, IS 302-1) |
- |
500 |
|
- |
| 19.3(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
| 19.3(Abnormal Operation, IS 302-1) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
- |
| 21.1(Mechanical Strength, IS 302-1 & IS 302-2-202) |
- |
500 |
|
- |
| 22(Construction, IS 302-1) |
- |
1000 |
|
- |
| 22.101(Construction) |
- |
0 |
|
- |
| 22.102(Construction) |
- |
0 |
|
- |
| 22.103(Construction) |
- |
0 |
|
- |
| 22.104(Construction) |
- |
0 |
|
- |
| 22.105(Construction) |
- |
0 |
|
- |
| 22.105.1(Construction) |
- |
0 |
|
- |
| 22.105.2(Construction) |
- |
0 |
|
- |
| 22.106(Construction) |
- |
0 |
|
- |
| 22.107(Construction) |
- |
0 |
|
- |
| 11.107.1(Construction) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.10(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 24.1(Components, IS 302-1) |
- |
500 |
|
- |
| 24.2(Components, IS 302-1) |
- |
0 |
|
- |
| 24.101(Components) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25.4(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
500 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
500 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
500 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
500 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
0 |
| 30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
- |
| 30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
500 |
|
- |
|
03 Oct, 2027 |
- Included w.e.f 04.08.2025
Exclusion: Cl 19.11.4.1-19.11.4.7(EMI/EMC) |
| 4 |
IS 302 : Part 2 : Sec 80 (2017) |
Household and similar electrical appliances - Safety: Part 2 - 80 particular requirements for fans (First Revision) |
- |
14900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 31.0(Resistance To Rusting) |
- |
1000 |
|
- |
| 30.0(Resistance To Heat and Fire) |
- |
1000 |
|
- |
| 29.0(Creepage Distances and Clearances) |
- |
300 |
|
- |
| 28.0(Screws and Connections) |
- |
300 |
|
- |
| 27.0(Provision For Earthing) |
- |
500 |
|
- |
| 26.0(Terminals for external conductors) |
- |
500 |
|
- |
| 25.0(Supply Connection and External Flexible Cords) |
- |
500 |
|
- |
| 24.0(Components) |
- |
300 |
|
- |
| 23.0(Internal Wiring) |
- |
500 |
|
- |
| 22.0(Construction) |
- |
300 |
|
- |
| 21.0(Mechanical Strength) |
- |
300 |
|
- |
| 20.0(Stability and mechanical hazards) |
- |
200 |
|
- |
| 19.0(Abnormal Operation) |
- |
1500 |
|
- |
| 17.0(Overload Protection of transformer and associated circuit) |
- |
200 |
|
- |
| 16.0(Leakage current and Electric strength (After Humidity (Environmental) Treatment)) |
- |
500 |
|
- |
| 15.0(Moisture resistance) |
- |
1500 |
|
- |
| 14.0(Transient Overvoltage) |
- |
500 |
|
- |
| 13.0(Leakage Current and electric strength at operating temperature) |
- |
500 |
|
- |
| 11.0(Heating) |
- |
1500 |
|
- |
| 10.0(Input and Current) |
- |
1500 |
|
- |
| 8.0(Protection against access to live parts) |
- |
1000 |
|
- |
| 7.0(Classification) |
- |
200 |
|
- |
| 6.0(Marking and Instructions) |
- |
300 |
|
- |
| 4(GENERAL REQUIREMENT) |
- |
200 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
200 |
|
- |
|
03 Oct, 2027 |
- Included w.e.f.31.07.2025
Exclusion
Cl 19.11.4.1 to Cl 19.11.4.7(EMI/EMC)
Cl 32 (Radiation, Toxicity and similar hazards) |
| 5 |
IS 4250 (2025) |
Electric Food-Mixers (Liquidizers and Grinders) and Centrifugal Juicers � Specification ( Second Revision ) |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(General Requirements) |
- |
500 |
|
- |
| Cl-5(General Conditions for the tests) |
- |
500 |
|
- |
| Cl-6(Classification) |
- |
500 |
|
- |
| Cl-7(Marking) |
- |
1000 |
|
- |
| Cl-8(Safety Requirements) |
- |
2000 |
|
- |
| Cl-9(Endurance fpr motor and base assembly) |
- |
5000 |
|
- |
| Cl-10.2("Grinding Coffee (for Machines that Have a
Dry Grinding Arrangement)") |
- |
1500 |
|
- |
| Cl-10.3(Whisking Egg Whites (for Machines that have Whisking Egg Arrangement)) |
- |
1500 |
|
- |
| Cl-10.4(Idli Batter) |
- |
1500 |
|
- |
| Cl-10.5(Operational Tests for Juicers) |
- |
1500 |
|
- |
| Cl-11(Temperature Withstand Test for Bowl) |
- |
1000 |
|
- |
| Cl-12.1(Test for Switches) |
- |
3000 |
|
- |
| Cl-13(Strength of Assembly) |
- |
1000 |
|
- |
| Cl-14.2, 14.3 Table-2 (i)(Protection against access to live parts) |
- |
1000 |
|
- |
| Cl-14.2, Table-2 (ii)(Power input and current) |
- |
2000 |
|
- |
| Cl-14.2, 14.3 Table-2 (iii)(Leakage current and electric strength at operating temperature) |
- |
2000 |
|
- |
| Cl-14.2, Table-2 (iv)(Moisture resistance) |
- |
2000 |
|
- |
| Cl-14.2, Table-2 (v)(Leakage current and electric strength) |
- |
2000 |
|
- |
| Cl-14.2, 14.3 Table-2 (vi)(Provision for earthing) |
- |
2000 |
|
- |
|
03 Oct, 2027 |
- - |
| 6 |
IS 14927 : Part 2 : Sec 1 (2023) |
Cable trunking systems and cable ducting Systems for electrical installations Part 2-1: particular requirements cable trunking systems and cable Ducting systems intended for mounting on walls and ceilings first revision |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.9.1(Sharp edges) |
- |
500 |
|
- |
| Cl.9.2(Apparatus mounting) |
- |
500 |
|
- |
| Cl.9.3(Means for protective separation and/or retention) |
- |
1000 |
|
- |
| Cl.9.4(Mechanical connections) |
- |
1000 |
|
- |
| Cl.9.5(Accessible conductive parts) |
- |
1000 |
|
- |
| Cl.9.6(Equipotential bonding) |
- |
500 |
|
- |
| Cl.9.7(Access to live parts) |
- |
1000 |
|
- |
| Cl.9.8(Inlet openings) |
- |
500 |
|
- |
| Cl.9.9(Membranes) |
- |
1000 |
|
- |
| Cl.9.10(Cable restrainer) |
- |
1000 |
|
- |
| Cl.9.11(Cable anchorage) |
- |
1000 |
|
- |
| Cl. 9.101(Assembling) |
- |
1000 |
|
- |
| Cl. 9.102(Contact between liquids and insulated conductors and live parts) |
- |
1000 |
|
- |
| Cl.10.1(Linear deflection test) |
- |
1000 |
|
- |
| Cl.10.1(Mechanical strength) |
- |
1000 |
|
- |
| Cl.10.2(Cable support test) |
- |
1000 |
|
- |
| Cl.10.3(Impact test) |
- |
1000 |
|
- |
| Cl.10.5(External load test) |
- |
500 |
|
- |
| Cl.10.6(System access cover retention) |
- |
500 |
|
- |
| Cl. 10.101(Compression test for CDS) |
- |
1500 |
|
- |
| Cl.11.1(Electrical continuity) |
- |
1000 |
|
- |
| Cl.11.2(Electrical insulation) |
- |
1000 |
|
- |
| Cl.12(Thermal properties) |
- |
1000 |
|
- |
| Cl.13(Fire hazard) |
- |
2000 |
|
- |
| Cl.14(External influences) |
- |
2000 |
|
- |
|
03 Oct, 2027 |
- Included w.e.f 18.08.2025
Exclusion: Cl. 15 (Electromagnetic compatibility) |
| 7 |
IS 3419 (1988) |
Specification for fittings for rigid non - Metallic (Second Revision) |
---- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8 & 5(Visual Examination -IS:3419) |
- |
500 |
|
- |
| 6.2 & 9.1- Table-1, ii(Inside Diameter of Collar for Slip type cuplers -IS:3419) |
- |
500 |
|
- |
| 6.2 & 9.1- Table-1, iii(Inside Diameter of Ridge for Slip type cuplers -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-1, iv(Minimum overall length for Slip type cuplers -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-1, v(Minimum wall thickness for Slip type cuplers -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-2, ii(Inside Diameter of Collar for Socketed type cuplers -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-2, iii(Inside Diameter of Ridge for Socketed type cuplers -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-2, iv(Minimum overall length (a) for Socketed type cuplers -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-2, v(Minimum overall length (l) for Socketed type cuplers -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-2, vi(Minimum wall thickness for Socketed type cuplers -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-3, ii(Inside Diameter of Collar(d6) for Clamp type cuplers -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-3, iii(Inside Diameter of Collar (d5) for Clamp type cuplers -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-3, iv(Inside Diameter of Ridge for Clamp type cuplers -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-3, iv(Minimum length for Clamp type cuplers -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-3, vi(Minimum wall thickness for Clamp type cuplers -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-4, ii(Outside Dameter of Normal type bend -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-4, iii(Minimum Inside Diameter of Normal Type Bend -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-4, iv(Radious(R) of Normal Type Bend -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-4, v(Length (l1) of Normal Type Bend -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-5, ii(Outside Dameter of Slip type cupling bend -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-5, iii(Minimum Inside Diameter of Slip type cupling bend -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-5, iv(Inside Diameter of collar for Slip type cupling bend -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-5, v(R- for Slip type cupling bend -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-5, vi(Y- for Slip type cupling bend -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-5, vii(l2- for Slip type cupling bend -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-6, ii(Inside Diameter of collar for Normal type Elbows -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-6, iii(Length (l) of Normal Type Elbows -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-6, iv(Radious(r) of Normal Type Elbows -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-6, v(Minimum wall thicknes of Elbows -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-7, ii(Inside Diameter of Collear for Normal type Tees -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-7, iii(Length (l) of Normal type Tees -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-7, iv(Radious(r) of Normal type Tees -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-7, v( Minimum wall thicknes of Normal type Tees -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-8, ii(Inside Diameter of Collear for socketed type Tees - IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-8, iii(a - of socketed type Tees -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-8, iv(l - of socketed type Tees -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-8, v(Minimum wall thicknes of socketed type Tees -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-9, ii(B - of spout Type Circular Boxes -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-9, iii(C - of spout Type Circular Boxes -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-9, iv(D - of spout Type Circular Boxes -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-9, v(E - of spout Type Circular Boxes -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-9, vi(F(Max) - of spout Type Circular Boxes -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-9, vii(F(Min) - of spout Type Circular Boxes -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-9, viii(G - of spout Type Circular Boxes -IS:3419) |
- |
0 |
|
- |
| 6.2 & 9.1- Table-9, ix(t - of spout Type Circular Boxes -IS:3419) |
- |
0 |
|
- |
| 10(Resistance to Heat -IS:3419) |
- |
1000 |
|
- |
| 11(Resistance to Burning - IS 3419) |
- |
1000 |
|
- |
| 12(Moisture Absorption - IS 3419) |
- |
500 |
|
- |
| 13.2 &13.3(Resistance to chemival action in Acid solution - IS 3419) |
- |
1000 |
|
- |
| 13.2 &13.3(Resistance to chemival action in Alkaline solution - IS 3419) |
- |
1000 |
|
- |
| 14.1(Copper Test - IS 3419) |
- |
1000 |
|
- |
| 15, 15.3(Resistance to Oil - IS 3419) |
- |
500 |
|
- |
| 15,15.4(Resistance to Oil - IS 3419) |
- |
500 |
|
- |
| 16- Appendix-A(Resistance to Impact -IS 3419) |
- |
500 |
|
- |
| 17.2(Electric Strength - IS 3419) |
- |
500 |
|
- |
| 17.3(Insulation Resistance - IS 3419) |
- |
500 |
|
- |
| Cl.7.1(Marking) |
- |
500 |
|
- |
| Cl.7.1(Construction) |
- |
500 |
|
- |
| Cl. 5(Construction) |
- |
0 |
|
- |
| Cl. 5(Construction) |
- |
0 |
|
- |
| Cl.5.3(Construction) |
- |
500 |
|
- |
| Cl.5.3(Construction) |
- |
0 |
|
- |
| (Cl.6) Table 9(Dimensions A) |
- |
500 |
|
- |
| (Cl.6) Table 9(Dimensions B) |
- |
0 |
|
- |
| (Cl.6) Table 9(Dimensions C) |
- |
0 |
|
- |
| (Cl.6) Table 9(Dimensions D) |
- |
0 |
|
- |
| (Cl.6) Table 9(Dimensions E) |
- |
0 |
|
- |
| (Cl.6) Table 9(Dimensions F) |
- |
0 |
|
- |
| (Cl.6) Table 9(Dimensions G) |
- |
0 |
|
- |
| (Cl.6) Table 9(Dimensions t) |
- |
0 |
|
- |
| Cl. 10(Resistance to Heat) |
- |
0 |
|
0 |
| Cl. 11(Resistance to Burning) |
- |
0 |
|
- |
| Cl. 12(Moisture Absorption Test) |
- |
0 |
|
- |
| Cl.13(Resistance to Chemical Action) |
- |
0 |
|
- |
| Cl.14(Copper Test) |
- |
0 |
|
- |
| Cl. 15(Resistance to Oil) |
- |
0 |
|
- |
| Cl. 15(Resistance to Oil) |
- |
0 |
|
- |
|
03 Oct, 2027 |
- Included w.e.f.29.07.2025 |
| 8 |
IS 9537 : Part 3 (1983) |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
---- |
4500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Marking) |
- |
100 |
|
- |
| 6.2(Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
200 |
|
- |
| 6.3(Standard Mark on Conduit) |
- |
100 |
|
- |
| 7.1.1(Maximum and minimum outside diameter of socket) |
- |
100 |
|
- |
| 7.1.1 Table-2(Length of Socket end) |
- |
100 |
|
- |
| 7.1.2(Maximum and minimum outside diameter of conduit) |
- |
200 |
|
- |
| 7.2(Minimum inside diameter of conduit) |
- |
200 |
|
- |
| 7.3(Length of conduit) |
- |
100 |
|
- |
| 7.4(Unifomity of The wall Thickness) |
- |
100 |
|
- |
| 8.1(Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
100 |
|
- |
| 9.2(Bending Test i) At Room Temp ii) At Low Temp (-5 ±2°C)) |
- |
300 |
|
- |
| 9.3(Compression Test as per caluse 9.3 of IS: 9537 (Part 1)-1980) |
- |
300 |
|
- |
| 9.4(Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
| 9.5(Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
300 |
|
- |
| 10(Resistance to Heat -Ball presure test) |
- |
300 |
|
- |
| 11(Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
| 12(Electrical Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
| 12(Electrical Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
| 13(Tests for external influence as per clause 13 of IS: 9537 (Part 1)-1980) |
- |
200 |
|
- |
| 13(Tests for external influence as per clause 13 of IS: 9537 (Part 1)-1980) |
- |
200 |
|
- |
| 12(3 Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
| 12(3 Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
| 11.0(Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
| 10.0(Resistance to Heat -Ball presure test) |
- |
300 |
|
- |
| 9.5 Fig.5(Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
300 |
|
- |
| 9.4(Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
| 9.3(Compression Test (after removal of force) as per caluse 9.3.3 of IS: 9537 (Part 1)-1980) |
- |
300 |
|
- |
| 9.3(Compression Test at Full force applied (On load)) |
- |
300 |
|
- |
| 9.2(Bending Test At Low Temp (-5 ±2°C)) |
- |
300 |
|
- |
| 9.2(Bending Test At Room Temp) |
- |
300 |
|
- |
| 8.1(Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
100 |
|
- |
| 7.4(Unifomity of The wall Thickness) |
- |
100 |
|
- |
| 7.3(Length of conduit) |
- |
100 |
|
- |
| 7.2 Fig.3(Minimum inside diameter of conduit) |
- |
200 |
|
- |
| 7.1.2 Fig.2(Minimum outside diameter of conduit) |
- |
200 |
|
- |
| 7.1.2 Fig.1(Maximum outside diameter of conduit) |
- |
200 |
|
- |
| 7.1.1 Table-2(Length of Socket end) |
- |
100 |
|
- |
| 7.1.1 Fig.8(Maximum inside diameter of socket) |
- |
100 |
|
- |
| 7.1.1 Fig.7(Maximum outside diameter of socket) |
- |
100 |
|
- |
| 6.3(Standard Mark on Conduit) |
- |
100 |
|
- |
| 6.2(Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
200 |
|
- |
| 6.1 - d(Marking) |
- |
100 |
|
- |
| 6.1 - c(Marking) |
- |
100 |
|
- |
| 6.1 - b(Marking) |
- |
100 |
|
- |
| 6.1 - a(Marking) |
- |
100 |
|
- |
|
03 Oct, 2027 |
- Included w.e.f.17.07.2025
Exclusion
13 (Tests for external influence as per clause 13 of IS: 9537 (Part 1)-1980) |
| 9 |
IS 302 : Part 1 (2024) |
Household and Similar Electrical Appliances â Safety Part 1 General Requirements (Seventh Revision) |
- |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 12(Charging of metal-ion batteries) |
- |
1000 |
|
- |
| 6(Classification- IS 302-1) |
- |
500 |
|
- |
| 5(General conditions for the tests) |
- |
500 |
|
- |
| 11.8(Temperature rise) |
- |
1000 |
|
- |
| 11.7(Duration corresponding) |
- |
1000 |
|
- |
| 11.6(Combined appliances) |
- |
500 |
|
- |
| 11.5(Motor-operated appliances) |
- |
1000 |
|
- |
| 11.4(Heating appliances) |
- |
1000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
500 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
- |
| 4(General requirement) |
- |
500 |
|
- |
| 31(Resistance to Rusting) |
- |
500 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.1(Ball pressure test) |
- |
500 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
- |
| 28(Screw test and connections) |
- |
500 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
| 26(Terminals for external conductors) |
- |
500 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 24(Components) |
- |
500 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
500 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
1000 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
500 |
|
- |
| 16.1(General) |
- |
500 |
|
- |
| 16.0(General) |
- |
1000 |
|
- |
| 15.3(Humidity Test) |
- |
500 |
|
- |
| 15.2(Spillage Test) |
- |
500 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
500 |
|
- |
| 15.0(Moisture resistance) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
1000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
500 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
1000 |
|
- |
| 11.3(Heating) |
- |
1000 |
|
- |
| 11.2(General) |
- |
500 |
|
- |
| 11.1(General) |
- |
500 |
|
- |
| 10.2(Current input) |
- |
500 |
|
- |
| 10.1(Power input) |
- |
1000 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
500 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
500 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
500 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
| A.2(Earth continuity test) |
- |
1000 |
|
- |
| Annex C(Ageing test on motors) |
- |
1000 |
|
- |
| Annex D(Thermal motor protectors) |
- |
1000 |
|
- |
| 15.2(Moisture resistance) |
- |
500 |
|
- |
| 19.17(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
1000 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
500 |
|
- |
| 21.3(Mechanical Strength, IS 302-1) |
- |
1000 |
|
- |
| 22.5(Construction) |
- |
500 |
|
- |
| 22.6(Construction, IS 302-1) |
- |
500 |
|
- |
| 22.11(Construction, IS 302-1) |
- |
500 |
|
- |
| 22.16(Construction) |
- |
500 |
|
- |
| 22.32(Construction, IS 302-1) |
- |
500 |
|
- |
| 22.42(Construction) |
- |
500 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
1000 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 26.5(Terminals for external conductors) |
- |
500 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
| 28.1(Screws and connections) |
- |
1000 |
|
- |
| 22.2(Construction, IS 302-1) |
- |
1000 |
|
- |
| 22.3(Construction, IS 302-1) |
- |
1000 |
|
- |
| B.22.4(Construction, IS 302-1) |
- |
1000 |
|
- |
| B.22.5(Construction, IS 302-1) |
- |
1000 |
|
- |
| 12(Charging of metal-ion batteries) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 5(General conditions for the tests) |
- |
0 |
|
- |
| 11.8(Temperature rise) |
- |
0 |
|
- |
| 11.7(Duration corresponding) |
- |
0 |
|
- |
| 11.6(Combined appliances) |
- |
0 |
|
- |
| 11.5(Motor-operated appliances) |
- |
0 |
|
- |
| 11.4(Heating appliances) |
- |
0 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 16(Leakage current and electric strength) |
- |
0 |
|
- |
| 4(General requirement) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 30.2(Needle Flame Test) |
- |
0 |
|
- |
| 30.2(Glow Wire Test) |
- |
0 |
|
- |
| 30.1(Ball pressure test) |
- |
0 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
0 |
|
- |
| 28(Screw test and connections) |
- |
0 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 26(Terminals for external conductors) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
- |
| 16.1(General) |
- |
0 |
|
- |
| 16.0(General) |
- |
0 |
|
- |
| 15.3(Humidity Test) |
- |
0 |
|
- |
| 15.2(Spillage Test) |
- |
0 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
0 |
|
- |
| 15.0(Moisture resistance) |
- |
0 |
|
- |
| 14(Transient Over Voltages) |
- |
0 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
0 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
0 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
| 11.3(Heating) |
- |
0 |
|
- |
| 11.2(General) |
- |
0 |
|
- |
| 11.1(General) |
- |
0 |
|
- |
| 10.2(Current input) |
- |
0 |
|
- |
| 10.1(Power input) |
- |
0 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
0 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| A.2(Earth continuity test) |
- |
0 |
|
- |
| Annex C(Ageing test on motors) |
- |
0 |
|
- |
| Annex D(Thermal motor protectors) |
- |
0 |
|
- |
| 15.2(Moisture resistance) |
- |
0 |
|
- |
| 19.17(Abnormal Operation, IS 302-1) |
- |
0 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.3(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 22.5(Construction) |
- |
0 |
|
- |
| 22.6(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.11(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.16(Construction) |
- |
0 |
|
- |
| 22.32(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.42(Construction) |
- |
0 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
0 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26.5(Terminals for external conductors) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28.1(Screws and connections) |
- |
0 |
|
- |
| 22.2(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.3(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.4(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.5(Construction, IS 302-1) |
- |
0 |
|
- |
| 12(Charging of metal-ion batteries) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 5(General conditions for the tests) |
- |
0 |
|
- |
| 11.8(Temperature rise) |
- |
0 |
|
- |
| 11.7(Duration corresponding) |
- |
0 |
|
- |
| 11.6(Combined appliances) |
- |
0 |
|
- |
| 11.5(Motor-operated appliances) |
- |
0 |
|
- |
| 11.4(Heating appliances) |
- |
0 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 16(Leakage current and electric strength) |
- |
0 |
|
- |
| 4(General requirement) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 30.2(Needle Flame Test) |
- |
0 |
|
- |
| 30.2(Glow Wire Test) |
- |
0 |
|
- |
| 30.1(Ball pressure test) |
- |
0 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
0 |
|
- |
| 28(Screw test and connections) |
- |
0 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 26(Terminals for external conductors) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
- |
| 16.1(General) |
- |
0 |
|
- |
| 16.0(General) |
- |
0 |
|
- |
| 15.3(Humidity Test) |
- |
0 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
0 |
|
- |
| 15.0(Moisture resistance) |
- |
0 |
|
- |
| 14(Transient Over Voltages) |
- |
0 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
0 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
0 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
| 11.3(Heating) |
- |
0 |
|
- |
| 11.2(General) |
- |
0 |
|
- |
| 11.1(General) |
- |
0 |
|
- |
| 10.2(Current input) |
- |
0 |
|
- |
| 10.1(Power input) |
- |
0 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
0 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| A.2(Earth continuity test) |
- |
0 |
|
- |
| Annex C(Ageing test on motors) |
- |
0 |
|
- |
| Annex D(Thermal motor protectors) |
- |
0 |
|
- |
| 19.17(Abnormal Operation, IS 302-1) |
- |
0 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.3(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 22.5(Construction) |
- |
0 |
|
- |
| 22.6(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.11(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.16(Construction) |
- |
0 |
|
- |
| 22.32(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.42(Construction) |
- |
0 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
0 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26.5(Terminals for external conductors) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28.1(Screws and connections) |
- |
0 |
|
- |
| 22.2(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.3(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.4(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.5(Construction, IS 302-1) |
- |
0 |
|
- |
| 15.2(Spillage Test) |
- |
0 |
|
- |
| 15.2(Moisture resistance) |
- |
0 |
|
- |
| 12(Charging of metal-ion batteries) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 5(General conditions for the tests) |
- |
0 |
|
- |
| 11.8(Temperature rise) |
- |
0 |
|
- |
| 11.7(Duration corresponding) |
- |
0 |
|
- |
| 11.6(Combined appliances) |
- |
0 |
|
- |
| 11.5(Motor-operated appliances) |
- |
0 |
|
- |
| 11.4(Heating appliances) |
- |
0 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 16(Leakage current and electric strength) |
- |
0 |
|
- |
| 4(General requirement) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 30.2(Needle Flame Test) |
- |
0 |
|
- |
| 30.2(Glow Wire Test) |
- |
0 |
|
- |
| 30.1(Ball pressure test) |
- |
0 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
0 |
|
- |
| 28(Screw test and connections) |
- |
0 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 26(Terminals for external conductors) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
- |
| 16.1(General) |
- |
0 |
|
- |
| 16.0(General) |
- |
0 |
|
- |
| 15.3(Humidity Test) |
- |
0 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
0 |
|
- |
| 15.0(Moisture resistance) |
- |
0 |
|
- |
| 14(Transient Over Voltages) |
- |
0 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
0 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
0 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
| 11.3(Heating) |
- |
0 |
|
- |
| 11.2(General) |
- |
0 |
|
- |
| 11.1(General) |
- |
0 |
|
- |
| 10.2(Current input) |
- |
0 |
|
- |
| 10.1(Power input) |
- |
0 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
0 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| A.2(Earth continuity test) |
- |
0 |
|
- |
| Annex C(Ageing test on motors) |
- |
0 |
|
- |
| Annex D(Thermal motor protectors) |
- |
0 |
|
- |
| 19.17(Abnormal Operation, IS 302-1) |
- |
0 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.3(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 22.5(Construction) |
- |
0 |
|
- |
| 22.6(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.11(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.16(Construction) |
- |
0 |
|
- |
| 22.32(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.42(Construction) |
- |
0 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
0 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26.5(Terminals for external conductors) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28.1(Screws and connections) |
- |
0 |
|
- |
| 22.2(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.3(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.4(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.5(Construction, IS 302-1) |
- |
0 |
|
- |
| 15.2(Spillage Test) |
- |
0 |
|
- |
| 15.2(Moisture resistance) |
- |
0 |
|
- |
| 12(Charging of metal-ion batteries) |
- |
- |
|
- |
| 6(Classification- IS 302-1) |
- |
- |
|
- |
| 5(General conditions for the tests) |
- |
- |
|
- |
| 11.8(Temperature rise) |
- |
- |
|
- |
| 11.7(Duration corresponding) |
- |
- |
|
- |
| 11.6(Combined appliances) |
- |
- |
|
- |
| 11.5(Motor-operated appliances) |
- |
- |
|
- |
| 11.4(Heating appliances) |
- |
- |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
- |
|
- |
| 18(Endurance) |
- |
- |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
- |
|
- |
| 16(Leakage current and electric strength) |
- |
- |
|
- |
| 4(General requirement) |
- |
- |
|
- |
| 31(Resistance to Rusting) |
- |
- |
|
- |
| 30.2(Needle Flame Test) |
- |
- |
|
- |
| 30.2(Glow Wire Test) |
- |
- |
|
- |
| 30.1(Ball pressure test) |
- |
- |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
- |
|
- |
| 28(Screw test and connections) |
- |
- |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
- |
|
- |
| 26(Terminals for external conductors) |
- |
- |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 22.1(Construction, IS 302-1) |
- |
- |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
- |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
- |
|
- |
| 19(Abnormal Operation) |
- |
- |
|
- |
| 18(Endurance) |
- |
- |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
- |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
- |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
- |
|
- |
| 16.1(General) |
- |
- |
|
- |
| 16.0(General) |
- |
- |
|
- |
| 15.3(Humidity Test) |
- |
- |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
- |
|
- |
| 15.0(Moisture resistance) |
- |
- |
|
- |
| 14(Transient Over Voltages) |
- |
- |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
- |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
- |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
- |
|
- |
| 11.3(Heating) |
- |
- |
|
- |
| 11.2(General) |
- |
- |
|
- |
| 11.1(General) |
- |
- |
|
- |
| 10.2(Current input) |
- |
- |
|
- |
| 10.1(Power input) |
- |
- |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
- |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
- |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
- |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
- |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
- |
|
- |
| 7(Marking and instructions) |
- |
- |
|
- |
| A.2(Earth continuity test) |
- |
- |
|
- |
| Annex C(Ageing test on motors) |
- |
- |
|
- |
| Annex D(Thermal motor protectors) |
- |
- |
|
- |
| 19.17(Abnormal Operation, IS 302-1) |
- |
- |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
- |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
- |
|
- |
| 21.3(Mechanical Strength, IS 302-1) |
- |
- |
|
- |
| 22.5(Construction) |
- |
- |
|
- |
| 22.6(Construction, IS 302-1) |
- |
- |
|
- |
| 22.11(Construction, IS 302-1) |
- |
- |
|
- |
| 22.16(Construction) |
- |
- |
|
- |
| 22.32(Construction, IS 302-1) |
- |
- |
|
- |
| 22.42(Construction) |
- |
- |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
- |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 26.5(Terminals for external conductors) |
- |
- |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
- |
|
- |
| 28.1(Screws and connections) |
- |
- |
|
- |
| 22.2(Construction, IS 302-1) |
- |
- |
|
- |
| 22.3(Construction, IS 302-1) |
- |
- |
|
- |
| B.22.4(Construction, IS 302-1) |
- |
- |
|
- |
| B.22.5(Construction, IS 302-1) |
- |
- |
|
- |
| 15.2(Spillage Test) |
- |
- |
|
- |
| 15.2(Moisture resistance) |
- |
- |
|
- |
|
03 Oct, 2027 |
- Included w.e.f 02.09.2025
Cl 19.11.4.1-19.11.4.7(EMI/EMC), Cl 24 (Components), Cl 32 (Radiation Toxicity and Similar Hazards) |
| 10 |
IS 302 : Part 2 : Sec 32 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 32 massage appliances |
----- |
38500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 31 302-2-32 : 1994(Resistance to Rusting) |
- |
2000 |
|
- |
| Cl. 30 302-2-32 : 1994(Resistance to Heat Fire & Tracking ) |
- |
2500 |
|
- |
| Cl. 29 302-2-32 : 1994(Clearances, Creepage Distances & Solid insulation ) |
- |
1500 |
|
- |
| Cl. 28 302-2-32 : 1994(Screws & Connections) |
- |
1000 |
|
- |
| Cl. 27 302-2-32 : 1994(Provision for Earthing ) |
- |
2000 |
|
- |
| Cl. 26 302-2-32 : 1994(Terminals for External conductors ) |
- |
1000 |
|
- |
| Cl. 25 302-2-32 : 1994(Supply Connection & External Flexible Cords) |
- |
2000 |
|
- |
| Cl. 24 302-2-32 : 1994(Components) |
- |
1000 |
|
- |
| Cl. 23 302-2-32 : 1994(Internal Wiring) |
- |
3000 |
|
- |
| Cl. 22 302-2-32 : 1994(Construction ) |
- |
1000 |
|
- |
| Cl. 21 302-2-32 : 1994(Mechanical strength) |
- |
1500 |
|
- |
| Cl. 20 302-2-32 : 1994(Stability & Mechanical Hazards) |
- |
1500 |
|
- |
| Cl. 19 302-2-32 : 1994(Abnormal Operation ) |
- |
3000 |
|
- |
| Cl. 18 302-2-32 : 1994(Endurance) |
- |
1000 |
|
- |
| Cl. 17 302-2-32 : 1994(Overload Protection of Transformers and Associated Circuit) |
- |
1500 |
|
- |
| Cl. 16 302-2-32 : 1994(Leakage Current & Electric Strength at Operating Temperature (After Humidity Treatment)) |
- |
1500 |
|
- |
| Cl. 15 302-2-32: 1994(Moisture Resistance Test ) |
- |
2000 |
|
- |
| Cl. 14 302-2-32 : 1994(Radio and television interference suppression / Transient over voltages) |
- |
1000 |
|
- |
| Cl. 13 302-2-32 : 1994(Leakage Current & Electric Strength at Operating Temperature) |
- |
1500 |
|
- |
| Cl. 11 302-2-32 : 1994(Temperature Rise) |
- |
3000 |
|
- |
| Cl. 10 302-2-32 : 1994(Power Input and Current ) |
- |
3000 |
|
- |
| Cl. 9 302-2-32 : 1994(Protection Against Electric Shock) |
- |
1000 |
|
- |
| Cl. 8 302-2-32 : 1994(Starting of motor operated appliances) |
- |
1500 |
|
- |
| Cl. 7 302-2-32 : 1994(Marking) |
- |
1000 |
|
- |
| (CI. 6 IS 302-2-32 : 1994(Classification ) |
- |
500 |
|
- |
|
03 Oct, 2027 |
- Included w.e.f 14.08.2025
Exclusion: Cl 19.11.4.1-19.11.4.7(EMI/EMC),Cl. 32 302-2-32 : 1994 (Radiation Hazards) |
| 11 |
IS 302 : Part 2 : Sec 8 (2024) |
Household and Similar Electrical Appliances âSafety Part 2 Particular Requirements Section 8 Shavers, Hair Clippers and Similar Appliances (First Revision) |
- |
28000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
1000 |
|
- |
| 8(Protection against access to live parts) |
- |
1500 |
|
- |
| 10(Power input and current) |
- |
1500 |
|
- |
| 11(Heating) |
- |
1500 |
|
- |
| 12(Charging of metal-ion batteries) |
- |
1500 |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
500 |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
500 |
|
- |
| 14(Transient overvoltages) |
- |
500 |
|
- |
| 15(Moisture resistance) |
- |
1000 |
|
- |
| 15.3(Moisture resistance) |
- |
1000 |
|
- |
| 16.1 &16.2(Leakage current test) |
- |
1000 |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
1000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1500 |
|
- |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
1500 |
|
- |
| 19.101(Abnormal operation) |
- |
1500 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
1000 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
1000 |
|
- |
| 21(Mechanical strength) |
- |
1000 |
|
- |
| 21.101(Mechanical strength) |
- |
1000 |
|
- |
| 21.102(Mechanical strength) |
- |
1000 |
|
- |
| 21.103(Mechanical strength) |
- |
1000 |
|
- |
| 22(Construction) |
- |
1000 |
|
- |
| 22.101(Construction) |
- |
1000 |
|
- |
| 22.102(Construction) |
- |
1000 |
|
- |
| 22.103(Construction) |
- |
1000 |
|
- |
| 23(Internal wiring) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
1500 |
|
- |
| 26("Terminals for external
conductors") |
- |
500 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 28(Screws and connections) |
- |
500 |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
500 |
|
- |
| 30(Resistance to heat and fire) |
- |
500 |
|
- |
| 31(Resistance to rusting) |
- |
500 |
|
- |
| 7(Marking and instructions) |
- |
1000 |
|
- |
| 8(Protection against access to live parts) |
- |
1500 |
|
- |
| 10(Power input and current) |
- |
1500 |
|
- |
| 11(Heating) |
- |
1500 |
|
- |
| 12(Charging of metal-ion batteries) |
- |
1500 |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
500 |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
500 |
|
- |
| 14(Transient overvoltages) |
- |
500 |
|
- |
| 15(Moisture resistance) |
- |
1000 |
|
- |
| 15.3(Moisture resistance) |
- |
1000 |
|
- |
| 16.1 &16.2(Leakage current test) |
- |
1000 |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
1000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1500 |
|
- |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
1500 |
|
- |
| 19.101(Abnormal operation) |
- |
1500 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
1000 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
1000 |
|
- |
| 21(Mechanical strength) |
- |
1000 |
|
- |
| 21.101(Mechanical strength) |
- |
1000 |
|
- |
| 21.102(Mechanical strength) |
- |
1000 |
|
- |
| 21.103(Mechanical strength) |
- |
1000 |
|
- |
| 22(Construction) |
- |
1000 |
|
- |
| 22.101(Construction) |
- |
1000 |
|
- |
| 22.102(Construction) |
- |
1000 |
|
- |
| 22.103(Construction) |
- |
1000 |
|
- |
| 23(Internal wiring) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
1500 |
|
- |
| 26("Terminals for external
conductors") |
- |
500 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 28(Screws and connections) |
- |
500 |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
500 |
|
- |
| 30(Resistance to heat and fire) |
- |
500 |
|
- |
| 31(Resistance to rusting) |
- |
500 |
|
- |
|
03 Oct, 2027 |
- Included w.e.f 14.08.2025
Exclusion: Cl 19.11.4.1-19.11.4.7(EMI/EMC), 32 ("Radiation, toxicity and similar hazards") |
| 12 |
IS 1293 (2019) |
Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) |
---- |
14800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(RATINGS) |
- |
100 |
|
- |
| 7.1.1(Accessories Classification) |
- |
50 |
|
- |
| 7.1.2(Accessories Classification) |
- |
50 |
|
- |
| 7.1.3(Accessories Classification) |
- |
50 |
|
- |
| 7.1.4(Accessories Classification) |
- |
50 |
|
- |
| 7.1.5(Accessories Classification) |
- |
50 |
|
- |
| 7.2.1(Socket-Outlets Classification) |
- |
50 |
|
- |
| 7.2.2(Socket-Outlets Classification) |
- |
50 |
|
- |
| 7.2.3(Socket-Outlets Classification) |
- |
50 |
|
- |
| 7.2.4(Socket-Outlets Classification) |
- |
50 |
|
- |
| 7.3(Plug Classification) |
- |
50 |
|
- |
| 8(Marking) |
- |
100 |
|
- |
| 9(CHECKING OF DIMENSIONS) |
- |
100 |
|
- |
| 10(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
2000 |
|
- |
| 11(Provision for earthing) |
- |
1500 |
|
- |
| 12(terminals) |
- |
50 |
|
- |
| 13.1(Construction of fixed Socket Outlets) |
- |
500 |
|
- |
| 13.2(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.3(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.4(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.5(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.6(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.7(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.8(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.9(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.10(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.11(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.12(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.14(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.17(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.18(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.19(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.2(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.21(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.22(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.23(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
500 |
|
- |
| 14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.3(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.4(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.5(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.6(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.7(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.8(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.9(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.10(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.11(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.12(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.14(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.15(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.16(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.17(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.18(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.21(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.22(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.23(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.24(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.25(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.26(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 16.1(Resistance to Ageing) |
- |
500 |
|
- |
| 16.3(Resistance to Humidity) |
- |
500 |
|
- |
| 17.1(RESISTANCE AND ELECTRIC STRENGTH) |
- |
100 |
|
- |
| 17.2(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
50 |
|
- |
| 18(OPERATION OF EARTHING CONTACTS) |
- |
50 |
|
- |
| 19(TEMPERATURE RISE) |
- |
1000 |
|
- |
| 20(Making & Breaking Capacity) |
- |
50 |
|
- |
| 21(Normal Operation) |
- |
100 |
|
- |
| 22.1(Verification of the Maximum Withdrawal Force) |
- |
100 |
|
- |
| 22.2(Verification of Minimum Withdrawal Force) |
- |
100 |
|
- |
| 23.1(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
100 |
|
- |
| 23.2(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
50 |
|
- |
| 23.3(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
50 |
|
- |
| 23.4(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
50 |
|
- |
| 24.1(MECHANICAL STRENGTH For all kinds of fixed socketoutlets) |
- |
100 |
|
- |
| 24.1(MECHANICAL STRENGTH For portable multiple and combined socket outlets with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
50 |
|
- |
| 24.1(MECHANICAL STRENGTH For surface mounting boxes) |
- |
50 |
|
- |
| 24.2(MECHANICAL STRENGTH For portable single socket-outlets: 1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
50 |
|
- |
| 24.2(MECHANICAL STRENGTH For portable multiple and combined socket outlets: 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
50 |
|
- |
| 24.2(MECHANICAL STRENGTH For plug 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
50 |
|
- |
| 24.2(MECHANICAL STRENGTH For plug 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
50 |
|
- |
| 24.4(MECHANICAL STRENGTH For portable single socket-outlets: 1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
50 |
|
- |
| 24.4(MECHANICAL STRENGTH For portable multiple and combined socket outlets: 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
50 |
|
- |
| 24.5(MECHANICAL STRENGTH For Plug 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
50 |
|
- |
| 24.6(MECHANICAL STRENGTH For screwed glands of accessories having an IP code higher than IP20) |
- |
50 |
|
- |
| 24.7(MECHANICAL STRENGTH For plug pins provided with insulating sleeves) |
- |
50 |
|
- |
| 24.8(MECHANICAL STRENGTH For shuttered socketoutlets) |
- |
50 |
|
- |
| 24.10(MECHANICAL STRENGTH For Plug (1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
50 |
|
- |
| 24.14.1(MECHANICAL STRENGTH For fixed socket-outlets) |
- |
50 |
|
- |
| 24.14.2(MECHANICAL STRENGTH For fixed socket-outlets) |
- |
50 |
|
- |
| 24.14.3(MECHANICAL STRENGTH For plugs and portable socketoutlets) |
- |
50 |
|
- |
| 24.15(MECHANICAL STRENGTH) |
- |
50 |
|
- |
| 24.16(MECHANICAL STRENGTH) |
- |
50 |
|
- |
| 25.1(Resistance to heat) |
- |
100 |
|
- |
| 25.2(Resistance to heat) |
- |
50 |
|
- |
| 25.3(Resistance to heat) |
- |
50 |
|
- |
| 25.4(Resistance to heat) |
- |
50 |
|
- |
| 26.1(SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
| 26.2(SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
50 |
|
- |
| 26.3(SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
50 |
|
- |
| 26.4(SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
50 |
|
- |
| 26.5(SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
50 |
|
- |
| 26.6(SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
50 |
|
- |
| 26.7(SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
50 |
|
- |
| 27.1(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
200 |
|
- |
| 27.2(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
50 |
|
- |
| 28.1.1(Glow-Wire Test) |
- |
500 |
|
- |
| 28.2(Resistance to Tracking) |
- |
500 |
|
- |
| 29(Resistance to Rusting) |
- |
500 |
|
- |
| 30.1(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES Pressure Test at High Temperature) |
- |
150 |
|
- |
| 30.2(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES Static Damp Heat Test) |
- |
50 |
|
- |
| 30.3(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES Tests at Low Temperature) |
- |
50 |
|
- |
| 30.4(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES Impact Test at Low Temperature) |
- |
50 |
|
- |
| 13.13(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.15(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 13.16(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
| 14.13(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.19(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 14.20(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
50 |
|
- |
| 15(INTERLOCKED SOCKET-OUTLETS) |
- |
50 |
|
- |
| 16.2(RESISTANCE TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
50 |
|
- |
| 17.3(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
50 |
|
- |
| 24.3(MECHANICAL STRENGTH for fixed socket-outlets with a main part intended to be mounted directly on a surface) |
- |
50 |
|
- |
| 24.5(MECHANICAL STRENGTH For portable single socket-outlets: 1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
50 |
|
- |
| 24.5(MECHANICAL STRENGTH For portable multiple and combined socket outlets: 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
50 |
|
- |
| 24.9(MECHANICAL STRENGTH For portable multiple and combined socket outlets (1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
50 |
|
- |
| 24.11(MECHANICAL STRENGTH For portable socketoutlets having means for suspension on a wall) |
- |
50 |
|
- |
| 24.12(MECHANICAL STRENGTH For portable socketoutlets having means for suspension on a wall) |
- |
50 |
|
- |
| 24.13(MECHANICAL STRENGTH For portable socketoutlets having means for suspension on a wall) |
- |
50 |
|
- |
| 27.3(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
50 |
|
- |
| 24.9(MECHANICAL STRENGTH For portable multiple and combined socket outlets (1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
50 |
|
- |
| 24.10(MECHANICAL STRENGTH For Plug (1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
50 |
|
- |
| 24.16(MECHANICAL STRENGTH For shroud of portable socket-outlets) |
- |
50 |
|
- |
|
03 Oct, 2027 |
- Included w.e.f. 11-02-2025 |
| 13 |
IS 302 : Part 2 : Sec 8 (1994) |
Safety of household and similar electrical appliances : part 2 particular requirements, section 8 electrical shavers hair, clippers and similar appliances |
---- |
22000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 31(Resistance to Rusting) |
- |
500 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
1000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
1000 |
|
- |
| 28(Screws & Connection) |
- |
500 |
|
- |
| 27(Provision For Earthing) |
- |
1500 |
|
- |
| 26(Terminals For External Conductors) |
- |
500 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
1000 |
|
- |
| 24(Component) |
- |
500 |
|
- |
| 23(Internal wiring) |
- |
500 |
|
- |
| 22(Construction) |
- |
500 |
|
- |
| 21(Mechanical strength) |
- |
500 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 19(Abnormal Operation) |
- |
1500 |
|
- |
| 18(Endurance) |
- |
200 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
500 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
1500 |
|
- |
| 15(Moisture Resistance) |
- |
1000 |
|
- |
| 14(Radio and Television Interference Suppression/ Transient Over Voltage) |
- |
1500 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
1500 |
|
- |
| 11(Temperature Rise/Heating) |
- |
1500 |
|
- |
| 10(Power Input
& Current) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
200 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
500 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
1000 |
|
- |
| 6(Classification) |
- |
500 |
|
- |
| 5(Rating) |
- |
100 |
|
- |
|
03 Oct, 2027 |
- Included w.e.f.11.12.2024
Exclusion
32 (Radiation ,Toxicity and similar hazards)
19.11.4.1 to 19.11.4.7 (EMC/EMI) |
| 14 |
IS 302 : Part 2 : Sec 21 (2024) |
Household and Similar Electrical Appliances�Safety Part 2 Particular Requirements Section 21 Storage Water Heaters |
----- |
19800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General requirement) |
- |
100 |
|
- |
| 5(General conditions for the tests) |
- |
100 |
|
- |
| 6(Classification) |
- |
100 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
| 8(Protection against access to live parts) |
- |
500 |
|
- |
| 9(Starting of motor-operated appliances) |
- |
100 |
|
- |
| 10(Power input and current) |
- |
2000 |
|
- |
| 11(Heating) |
- |
1500 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
1500 |
|
- |
| 18(Endurance) |
- |
100 |
|
- |
| 19(Abnormal operation) |
- |
1000 |
|
- |
| 20(Stability and mechanical hazards) |
- |
300 |
|
- |
| 21(Mechanical strength) |
- |
300 |
|
- |
| 22(Construction) |
- |
200 |
|
- |
| 23(Internal wiring) |
- |
200 |
|
- |
| 24(Components) |
- |
200 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 26(Terminals for external conductors) |
- |
500 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 28(Screws and connections) |
- |
500 |
|
- |
| 29(Clearances, creepage distances and solid insulation) |
- |
500 |
|
- |
| 30(Resistance to heat and fire) |
- |
500 |
|
- |
| 31(Resistance to rusting) |
- |
1000 |
|
- |
| A.101(Pressure test) |
- |
500 |
|
- |
| 12(Charging of metal-ion batteries) |
- |
100 |
|
- |
| 22.101(rated pressure) |
- |
500 |
|
- |
| 22.102(Closed water heaters) |
- |
500 |
|
- |
| 22.103(Addition) |
- |
500 |
|
- |
| 22.104(Addition) |
- |
500 |
|
- |
| 22.105(Cistern-type water heaters) |
- |
500 |
|
- |
| 22.109(Addition) |
- |
500 |
|
- |
| 14(Transient overvoltages) |
- |
1000 |
|
- |
| 15(Moisture resistance) |
- |
500 |
|
- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
500 |
|
- |
|
03 Oct, 2027 |
- Included .w.e.f.04.12.2024
Exclusion
19.11.4.1 (Electrostatic discharges)
19.11.4.2 (Radiated fields)
19.11.4.3 (Fast transient bursts)
19.11.4.4 (Surge immunity test)
19.11.4.5 (Immunity to conducted discharges)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.7 (Harmonics)
32 (RADIATION TOXICITY AND SIMILAR HAZARDS) |
| 15 |
IS 302 : Part 2 : SEC 31 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 31 range hoods |
---- |
36000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
500 |
|
- |
| Clause No - 5.18(linear and angular dimension) |
- |
500 |
|
- |
| Clause No - 6.2(harmfull ingress of water) |
- |
500 |
|
- |
| Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
500 |
|
- |
| Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
500 |
|
- |
| Clause No - 8.2(Addition) |
- |
500 |
|
- |
| Clause No - 10.1, Table No. -1(power input deviation) |
- |
4000 |
|
- |
| Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
1000 |
|
- |
| Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
1000 |
|
- |
| Clause No - 14(Impulse test voltage) |
- |
1500 |
|
- |
| Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
1000 |
|
- |
| Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
1000 |
|
- |
| Clause No -21.1(Mechanical strength) |
- |
500 |
|
- |
| Clause No -22.1(construction) |
- |
500 |
|
- |
| Clause No -22.11(push force applied) |
- |
500 |
|
- |
| Clause No -24.1.2(safety isolating transformer) |
- |
500 |
|
- |
| Clause No -24.1.3(for switches) |
- |
1000 |
|
- |
| Clause No -24.1.4(for automatic control) |
- |
1000 |
|
- |
| Clause No -24.1.5(for innterconnection couplers) |
- |
1000 |
|
- |
| Clause No -24.4(plug and socket) |
- |
1000 |
|
- |
| Clause No -25.8, Table no -11(conductor resistance) |
- |
1000 |
|
- |
| Clause No -25.5(dimension for pins) |
- |
1000 |
|
- |
| Clause No -27.6(for circuit board) |
- |
1000 |
|
- |
| Clause No -29.2(comparative tracking index) |
- |
1000 |
|
- |
| Clause No -29.3.3(dry heat test) |
- |
1000 |
|
- |
| Clause No -30.2.1(glow wire test) |
- |
1000 |
|
- |
| Clause No -30.101("incorporate combustible
material") |
- |
1000 |
|
- |
| Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
500 |
|
- |
| Clause No - 5.18(linear and angular dimension) |
- |
500 |
|
- |
| Clause No - 6.2(harmfull ingress of water) |
- |
1000 |
|
- |
| Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
1000 |
|
- |
| Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
1000 |
|
- |
| Clause No - 8.2(Addition) |
- |
1000 |
|
- |
| Clause No - 10.1, Table No. -1(power input deviation) |
- |
0 |
|
- |
| Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
0 |
|
- |
| Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
0 |
|
- |
| Clause No - 14(Impulse test voltage) |
- |
0 |
|
- |
| Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
0 |
|
- |
| Clause No -21.1(Mechanical strength) |
- |
0 |
|
- |
| Clause No -22.1(construction) |
- |
0 |
|
- |
| Clause No -22.11(push force applied) |
- |
0 |
|
- |
| Clause No -24.1.2(safety isolating transformer) |
- |
0 |
|
- |
| Clause No -24.1.3(for switches) |
- |
0 |
|
- |
| Clause No -24.1.4(for automatic control) |
- |
0 |
|
- |
| Clause No -24.1.5(for innterconnection couplers) |
- |
0 |
|
- |
| Clause No -24.4(plug and socket) |
- |
0 |
|
- |
| Clause No -25.8, Table no -11(conductor resistance) |
- |
0 |
|
- |
| Clause No -25.5(dimension for pins) |
- |
0 |
|
- |
| Clause No -27.6(for circuit board) |
- |
0 |
|
- |
| Clause No -29.2(comparative tracking index) |
- |
0 |
|
- |
| Clause No -29.3.3(dry heat test) |
- |
0 |
|
- |
| Clause No -30.2.1(glow wire test) |
- |
0 |
|
- |
| Clause No -30.101("incorporate combustible
material") |
- |
0 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
500 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1000 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1000 |
|
- |
| 18(ENDURANCE) |
- |
1000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
- |
| Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
| Clause No - 5.18(linear and angular dimension) |
- |
0 |
|
- |
| Clause No - 6.2(harmfull ingress of water) |
- |
0 |
|
- |
| Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
0 |
|
- |
| Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
0 |
|
- |
| Clause No - 8.2(Addition) |
- |
0 |
|
- |
| Clause No - 10.1, Table No. -1(power input deviation) |
- |
0 |
|
- |
| Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
0 |
|
- |
| Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
0 |
|
- |
| Clause No - 14(Impulse test voltage) |
- |
0 |
|
- |
| Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
0 |
|
- |
| Clause No -21.1(Mechanical strength) |
- |
0 |
|
- |
| Clause No -22.1(construction) |
- |
0 |
|
- |
| Clause No -22.11(push force applied) |
- |
0 |
|
- |
| Clause No -24.1.2(safety isolating transformer) |
- |
0 |
|
- |
| Clause No -24.1.3(for switches) |
- |
0 |
|
- |
| Clause No -24.1.4(for automatic control) |
- |
0 |
|
- |
| Clause No -24.1.5(for innterconnection couplers) |
- |
0 |
|
- |
| Clause No -24.4(plug and socket) |
- |
0 |
|
- |
| Clause No -25.8, Table no -11(conductor resistance) |
- |
0 |
|
- |
| Clause No -25.5(dimension for pins) |
- |
0 |
|
- |
| Clause No -27.6(for circuit board) |
- |
0 |
|
- |
| Clause No -29.2(comparative tracking index) |
- |
0 |
|
- |
| Clause No -29.3.3(dry heat test) |
- |
0 |
|
- |
| Clause No -30.2.1(glow wire test) |
- |
0 |
|
- |
| Clause No -30.101("incorporate combustible
material") |
- |
0 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
0 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
0 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
0 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
- |
| Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
| Clause No - 5.18(linear and angular dimension) |
- |
0 |
|
- |
| Clause No - 6.2(harmfull ingress of water) |
- |
0 |
|
- |
| Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
0 |
|
- |
| Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
0 |
|
- |
| Clause No - 8.2(Addition) |
- |
0 |
|
- |
| Clause No - 10.1, Table No. -1(power input deviation) |
- |
0 |
|
- |
| Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
0 |
|
- |
| Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
0 |
|
- |
| Clause No - 14(Impulse test voltage) |
- |
0 |
|
- |
| Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
0 |
|
- |
| Clause No -21.1(Mechanical strength) |
- |
0 |
|
- |
| Clause No -22.1(construction) |
- |
0 |
|
- |
| Clause No -22.11(push force applied) |
- |
0 |
|
- |
| Clause No -24.1.2(safety isolating transformer) |
- |
0 |
|
- |
| Clause No -24.1.3(for switches) |
- |
0 |
|
- |
| Clause No -24.1.4(for automatic control) |
- |
0 |
|
- |
| Clause No -24.1.5(for innterconnection couplers) |
- |
0 |
|
- |
| Clause No -24.4(plug and socket) |
- |
0 |
|
- |
| Clause No -25.8, Table no -11(conductor resistance) |
- |
0 |
|
- |
| Clause No -25.5(dimension for pins) |
- |
0 |
|
- |
| Clause No -27.6(for circuit board) |
- |
0 |
|
- |
| Clause No -29.2(comparative tracking index) |
- |
0 |
|
- |
| Clause No -29.3.3(dry heat test) |
- |
0 |
|
- |
| Clause No -30.2.1(glow wire test) |
- |
0 |
|
- |
| Clause No -30.101("incorporate combustible
material") |
- |
0 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
0 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
0 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
0 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
- |
|
03 Oct, 2027 |
- Included.w.e.f.26.11.2024 Exclusion - 19.11.4.1 to 19.11.4.4 (EMI/EMC) |
| 16 |
IS 8978 (1992) |
Specification for electric instantaneous water heaters (Second Revision) |
---- |
14800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
200 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
- |
| Cl.6 of IS 302-2-35:2017(Classification) |
- |
100 |
|
- |
| Cl.6 of IS 302-2-35:2017(Classification) |
- |
0 |
|
- |
| Cl.8 of IS 302-2-35:2017(Protection Against Access To Live Parts) |
- |
500 |
|
- |
| Cl.10 of IS 302-2- 35:2011(Power Input & Current ) |
- |
1200 |
|
- |
| Cl.11 of 302-2-35:2017(Heating) |
- |
1000 |
|
- |
| Cl.11 of 302-2-35:2017(Heating) |
- |
0 |
|
- |
| Cl.11 of 302-2-35:2017(Heating) |
- |
0 |
|
- |
| Cl.11 of 302-2-35:2017(Heating) |
- |
0 |
|
- |
| Cl.13 of IS 302-2-35:2017(Leakage Current & Electrical Strength at Operating Temperature ) |
- |
1000 |
|
- |
| Cl.13 of IS 302-2-35:2017(Leakage Current & Electrical Strength at Operating Temperature ) |
- |
0 |
|
- |
| Cl.14 of IS 302-2-35:2017(Transient Over Voltages ) |
- |
500 |
|
- |
| Cl.15 of IS 302-2-35-2011(Moisture Resistance ) |
- |
500 |
|
- |
| Cl.15 of IS 302-2-35-2011(Moisture Resistance ) |
- |
0 |
|
- |
| Cl.16 of IS 302-2-35:2011(Leakage Current and Electric Strength) |
- |
500 |
|
- |
| Cl.16 of IS 302-2-35:2011(Leakage Current and Electric Strength) |
- |
0 |
|
- |
| Cl.17 IS 302-2-35:2017(Overload Protection of Transformers & Associated circuits ) |
- |
200 |
|
- |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation) |
- |
500 |
|
- |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation) |
- |
0 |
|
- |
| Cl.20 of IS 302-2-35-2011(Stability & Mechanical Hazards
) |
- |
200 |
|
- |
| Cl.21.1 of IS 302-2-35-2011(Mechanical strength) |
- |
200 |
|
- |
| Cl. 21.2 of IS 302-1:2008(Mechanical strength) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
500 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
- |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
500 |
|
- |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
- |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
- |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
- |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
- |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
- |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
- |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
- |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
- |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
- |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
- |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
- |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
- |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-35:2017(Component
) |
- |
200 |
|
- |
| Cl.24 of IS 302-2-35:2017(Component
) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-35:2017(Component
) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-35:2017(Component
) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
500 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
500 |
|
- |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
0 |
|
- |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
0 |
|
- |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
0 |
|
- |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
0 |
|
- |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
0 |
|
- |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
0 |
|
- |
| Cl.28 of IS 302-2-35:2017(Screws and Connections
) |
- |
200 |
|
- |
| Cl.29 of IS 302-2-35:2017(Clearances, Creepage Distances and Solid Insulation) |
- |
500 |
|
- |
| Cl.29 of IS 302-2-35:2017(Clearances, Creepage Distances and Solid Insulation) |
- |
0 |
|
- |
| Cl.29 of IS 302-2-35:2017(Clearances, Creepage Distances and Solid Insulation) |
- |
0 |
|
- |
| Cl.30 of IS 302-2-35: 2011(Resistance to Heat and Fire) |
- |
500 |
|
- |
| Cl.30 of IS 302-2-35: 2011(Resistance to Heat and Fire) |
- |
0 |
|
- |
| Cl.31 of IS 302-2-35: 2011(Resistance to Rusting
) |
- |
200 |
|
- |
| Cl.10 of IS 8978 : 1992(Finish) |
- |
500 |
|
- |
| Cl.11 of IS 8978 : 1992(Operation of flow switch) |
- |
500 |
|
- |
| Cl.12 of IS 8978 : 1992(Endurance) |
- |
500 |
|
- |
| Cl.12 of IS 8978 : 1992(Endurance) |
- |
0 |
|
- |
| Cl.10 of IS 8978 : 1992(Finish) |
- |
0 |
|
- |
| Cl.31 of IS 302-2-35: 2017(Resistance to Rusting
) |
- |
0 |
|
- |
| Cl.30.2 of IS 302-1:2008(Resistance to Heat and Fire) |
- |
50 |
|
- |
| Cl.30.1 of IS 302-1:2008(Resistance to Heat and Fire) |
- |
0 |
|
- |
| Cl.29.2 of IS 302-2-35:2017(Clearances, Creepage Distances and Solid Insulation : Creepage distance ) |
- |
50 |
|
- |
| Cl.29.1 of IS 302-2-35:2017(Clearances, Creepage Distances and Solid Insulation : Clearance distance ) |
- |
50 |
|
- |
| Cl.28 of IS 302-2-35:2017(Screws and Connections
) |
- |
50 |
|
- |
| Cl.27.5 of IS 302-2-35:2017(Provision for Earthing : ECR ) |
- |
50 |
|
- |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
0 |
|
- |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
- |
| Cl.23 of IS 302-2-35:2017(Internal Wiring ; Colour of earthing conductor) |
- |
50 |
|
- |
| Cl.23 of IS 302-2-35:2017(Internal Wiring) |
- |
0 |
|
- |
| Cl.22.110 of IS 302-2-35:2017(Construction : Provision for fixing to wall
) |
- |
50 |
|
- |
| Cl.22.109 of IS 302-2-35:2017(Construction : Operation of presure switch of open outlet water heater
) |
- |
50 |
|
- |
| Cl.22.108 of IS 302-2-35:2017(Construction : Temperature of outlet water intended to supply for showring
) |
- |
50 |
|
- |
| Cl.22.107 of IS 302-2-35:2017(Construction : Temperature of outlet
) |
- |
50 |
|
- |
| Cl.22.106 of IS 302-2-35:2017(Construction : Operation of thermal cut out for closed water heater
) |
- |
50 |
|
- |
| Cl.22.104 of IS 302-2-35:2017(Construction : Pressure in open outlet water heaters
) |
- |
50 |
|
- |
| Cl.22.103 of IS 302-2-35:2017(Construction : Pressure relief device operation for closed water heater
) |
- |
50 |
|
- |
| Cl.22.102 of IS 302-2-35:2017(Construction : excessive temperature of outlet
) |
- |
50 |
|
- |
| Cl.22.101 of IS 302-2-35:2017(Construction : Rated pressure of closed water heater
) |
- |
50 |
|
- |
| Cl.22.47 of IS 302-2-35:2017(Construction : Water pressure test
) |
- |
50 |
|
- |
| Cl.22.44 of IS 302-1:2008(Construction : Shape and decoration
) |
- |
50 |
|
- |
| Cl.22.34, Cl 22.35 of
IS 302-1:2008(Construction : Shaft of operating Knobs ) |
- |
50 |
|
- |
| Cl.22.33 of
IS 302-1:2008(Construction : Direct contact of liquids ) |
- |
50 |
|
- |
| Cl 22.26 ,Cl.22.28, Cl 22.29, Cl 22.30 , Cl 22.31, Cl 22.32 of
IS 302-1:2008(Construction : Supplymentry/ double / reinforced insulation for Class II/ Class III appliance ) |
- |
50 |
|
- |
| Cl.22.18 of IS 302-1:2008(Construction : Resistance to corrosion
) |
- |
50 |
|
- |
| Cl.22.17 of IS 302-1:2008(Construction : Spacers
) |
- |
50 |
|
- |
| Cl.22.14 of IS 302-1:2008(Construction : Ragged or sharp edges
) |
- |
50 |
|
- |
| Cl.22.12 of IS 302-1:2008(Construction : Fixing of Handle, knob, grips, levers and similar parts
) |
- |
50 |
|
- |
| Cl.22.11 of IS 302-1:2008(Construction : Fixing of non detachable parts
) |
- |
50 |
|
- |
| Cl.22.7 of IS 302-1:2008(Construction : safeguards against the risk of excessive pressure.
) |
- |
50 |
|
- |
| Cl.22.6 of IS 302-2-35:2017(Construction : size of drain hole
) |
- |
100 |
|
- |
| Cl.22.6 of IS 302-1:2008(Construction : effect of water on 3 insulation
) |
- |
100 |
|
- |
| Cl.22.2 of IS 302-1:2008(Construction : connection to supply mains
) |
- |
100 |
|
- |
| Cl.22.1 of IS 302-1:2008(Construction : IP test
) |
- |
100 |
|
- |
| Cl. 21.2 of IS 302-1:2008(Mechanical strength : prevent penetration by sharp implements. ) |
- |
50 |
|
- |
| Cl.21.1 of IS 302-1:2008(Mechanical strength : Rough handling in normal use) |
- |
100 |
|
- |
| Cl.20 of IS 302-2-35:2017(Stability & Mechanical Hazards
) |
- |
200 |
|
- |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation : effect on container) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation : High voltage) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation : Temperature rise of insulation of supply cord) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation : Temperature rise of test corner) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation : Emission of flames, molten metal ,or poisonous or ignitable gas) |
- |
0 |
|
- |
| Cl.16 of IS 302-2-35:2017(Leakage Current and Electric Strength (After Humidity)) |
- |
0 |
|
- |
| Cl.16 of IS 302-2-35:2017(Leakage Current and Electric Strength (After Humidity)) |
- |
0 |
|
- |
| Cl.15 of IS 302-2-35:2017(Moisture Resistance ) |
- |
0 |
|
- |
| Cl.14 of IS 302-2-35:2017(Transient Over Voltages ) |
- |
0 |
|
- |
| Cl.13 of IS 302-2-35:2017(Leakage Current & 3 Strength at Operating Temperature : High voltage ) |
- |
100 |
|
- |
| Cl.13 of IS 302-2-35:2017(Leakage Current & 3 Strength at Operating Temperature ) |
- |
100 |
|
- |
| Cl.11 of 302-2-35:2017(Heating : room temperature) |
- |
100 |
|
- |
| Cl.11 of 302-2-35:2017(Heating : Insulation of supply cord) |
- |
100 |
|
- |
| Cl.11 of 302-2-35:2017(Heating : Temperature rise of test corner) |
- |
100 |
|
- |
| Cl.10 of IS 302-2- 35:2017(Power Input & Current ) |
- |
0 |
|
- |
| Cl.8 of IS 302-2-35:2017(Protection Against Access To Live Parts) |
- |
0 |
|
- |
| Cl.7.102 of IS 302-2-35:2017(Marking : Standard mark) |
- |
0 |
|
- |
| Cl.7.101 of IS 302-2-35:2017(Marking : Woter inlet and outlet idetification) |
- |
0 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking : Position of marking) |
- |
0 |
|
- |
| Cl.7.14 of IS 302-1:2008(Marking ; Legibility and durability) |
- |
100 |
|
- |
| Cl.7.13 of IS 302-1:2008(Marking : Language) |
- |
0 |
|
- |
| Cl.7.10 & 7.11 of IS 302-1:2008(Marking : Indication for direction of control) |
- |
0 |
|
- |
| Cl.7.8 of IS 302-1:2008(Marking : Terminal for connection ) |
- |
0 |
|
- |
| Cl.7.6 of IS 302-1:2008(Marking : Symbols) |
- |
0 |
|
- |
| Cl.7.1 of IS 302-2-35:2017(Marking : rated pressure) |
- |
0 |
|
- |
| Cl.7.1 of IS 302-1:2008(Marking : Country of manufacture) |
- |
0 |
|
- |
| Cl.7.1 of IS 302-1:2008(Marking : IP number ) |
- |
0 |
|
- |
| Cl.7.1 of IS 302-1:2008(Marking : Symbol for class II) |
- |
0 |
|
- |
| Cl.7.1 of IS 302-1:2008(Marking : Molel or type) |
- |
0 |
|
- |
| Cl.7.1 of IS 302-1:2008(Marking : Manufacture identification) |
- |
0 |
|
- |
| Cl.7.1 of IS 302-1:2008(Marking : Rated power input) |
- |
0 |
|
- |
| Cl.7.1 of IS 302-1:2008(Marking : Nature of supply) |
- |
0 |
|
- |
| Cl.7.1 of IS 302-1:2008(Marking : Rated Voltage) |
- |
0 |
|
- |
| 4(GENERAL REQUIREMENTS) |
- |
0 |
|
- |
| 5(GENERAL NOTE ON TEST) |
- |
0 |
|
- |
| 7(Marking) |
- |
0 |
|
- |
| 7(Marking) |
- |
0 |
|
- |
| (Cl.7.1 of IS 302-2-35:2017)(Marking) |
- |
0 |
|
- |
| (Cl.7.101 of IS 302-2-35:2017)(Marking) |
- |
100 |
|
- |
| (Cl.8.1.1 of IS 8978:1992)(Marking) |
- |
0 |
|
- |
| (Cl.19.13 of IS 302-2-35:2017)(Abnormal operation) |
- |
50 |
|
- |
| (Cl.19.13 of IS 302-2-35:2017)(Abnormal operation) |
- |
0 |
|
- |
| (Cl.22 of IS 302-2-35:2017)(Construction) |
- |
0 |
|
- |
| (Cl.22 of IS 302-2-35:2017)(Construction) |
- |
0 |
|
- |
| (Cl.22 of IS 302-2-35:2017)(Construction) |
- |
0 |
|
- |
| (Cl.22 of IS 302-2-35:2017)(Construction) |
- |
0 |
|
- |
| (Cl.22 of IS 302-2-35:2017)(Construction) |
- |
0 |
|
- |
| (Cl.22 of IS 302-2-35:2017)(Construction) |
- |
0 |
|
- |
| (Cl.22 of IS 302-2-35:2017)(Construction) |
- |
0 |
|
- |
| (Cl.22 of IS 302-2-35:2017)(Construction) |
- |
0 |
|
- |
| (Cl.22 of IS 302-2-35:2017)(Construction) |
- |
0 |
|
- |
| (Cl.22 of IS 302-2-35:2017)(Construction) |
- |
0 |
|
- |
| (Cl.23 of IS 302-2-35:2017)(Internal wiring) |
- |
0 |
|
- |
| (Cl.23 of IS 302-2-35:2017)(Internal wiring) |
- |
0 |
|
- |
| (Cl.23 of IS 302-2-35:2017)(Internal wiring) |
- |
0 |
|
- |
| (Cl.23 of IS 302-2-35:2017)(Internal wiring) |
- |
0 |
|
- |
| (Cl.24 of IS 302-2-35:2017)(Components) |
- |
0 |
|
- |
| (Cl.24 of IS 302-2-35:2017)(Components) |
- |
0 |
|
- |
| (Cl.24 of IS 302-2-35:2017)(Components) |
- |
0 |
|
- |
| (Cl.24 of IS 302-2-35:2017)(Components) |
- |
0 |
|
- |
| (Cl.24 of IS 302-2-35:2017)(Components) |
- |
0 |
|
- |
| (Cl.25.8 of IS 302-2-35:2017)(Supply Connection and External Flexible cords) |
- |
300 |
|
- |
| (CL.27.5 of IS 302-2-35:2017)(Provision for Earthing) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-35:2017(Component
) |
- |
0 |
|
- |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
- |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
- |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
- |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
- |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
- |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
- |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
- |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
- |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
- |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
- |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
- |
| Cl.25.18 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.25.15 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : Cord grip test - displacement ) |
- |
0 |
|
- |
| Cl.25.15 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : Cord grip test ) |
- |
0 |
|
- |
| Cl.25.12 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : Moulding of supply cord ) |
- |
0 |
|
- |
| Cl.25.10 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : Colour of Earthing conductor ) |
- |
0 |
|
- |
| Cl.25.8 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : Resistance of supply cord ) |
- |
0 |
|
- |
| Cl.25.5 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : Type of attachment ) |
- |
0 |
|
- |
| Cl.25.1 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : connection to the supply mains) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-35:2017(Component
) |
- |
0 |
|
- |
|
03 Oct, 2027 |
- Included.w.e.f.26.11.2024 Exclusion 32 (RADIATION, TOXICITY AND SIMILAR HAZARDS), 19.11.4.1 to 19.11.4.7 (EMI/EMC). |
| 17 |
IS 369 (2019) |
Household electric direct - Acting room heaters - Performance requirements (Fourth Revision) |
---- |
16500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 of IS 302-2-30:2007(Classification) |
- |
200 |
|
- |
| Cl.6 of IS 302-2-30:2007(Classification) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
200 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
| Cl.8 of IS 302-2-30:2007 &IS:302-1:2008(Protection Against Access to Live Parts) |
- |
200 |
|
- |
| Cl.10 of IS 302-2-30:2007 &IS:302-1:2008(Power Input and Current) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
- |
| Cl.13 of IS 302-2-30:2007 &IS:302-1:2008(Leakage Current & Electric Strength at operating temp) |
- |
1000 |
|
- |
| Cl.13 of IS 302-2-30:2007 &IS:302-1:2008(Leakage Current & Electric Strength at operating temp) |
- |
0 |
|
- |
| Cl.14 of IS 302-2-30:2007 &IS:302-1:2008(Transient Over Voltages) |
- |
200 |
|
- |
| Cl.14 of IS 302-2-30:2007 &IS:302-1:2008(Transient Over Voltages) |
- |
0 |
|
- |
| Cl.14 of IS 302-2-30:2007 &IS:302-1:2008(Transient Over Voltages) |
- |
0 |
|
- |
| Cl.14 of IS 302-2-30:2007 &IS:302-1:2008(Transient Over Voltages) |
- |
0 |
|
- |
| Cl.15 of IS 302-2-30:2007 &IS:302-1:2008(Moisture Resistance) |
- |
200 |
|
- |
| Cl.15 of IS 302-2-30:2007 &IS:302-1:2008(Moisture Resistance) |
- |
0 |
|
- |
| Cl.16 of IS 302-2-30:2007 &IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
1000 |
|
- |
| Cl.16 of IS 302-2-30:2007 &IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
0 |
|
- |
| Cl.18 of IS 302-2-30:2007 (Endurance) |
- |
200 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
500 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.20 of IS 302-2-30:2007 &IS:302-1:2008(Stability & Mechanical Hazards) |
- |
200 |
|
- |
| Cl.21 of IS 302-2-30:2007 &IS:302-1:2008(Mechanical Strength) |
- |
200 |
|
- |
| Cl.21 of IS 302-2-30:2007 &IS:302-1:2008(Mechanical Strength) |
- |
0 |
|
- |
| Cl.21 of IS 302-2-30:2007 &IS:302-1:2008(Mechanical Strength) |
- |
0 |
|
- |
| Cl.21 of IS 302-2-30:2007 &IS:302-1:2008(Mechanical Strength) |
- |
0 |
|
- |
| Cl.21 of IS 302-2-30:2007 &IS:302-1:2008(Mechanical Strength) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
200 |
|
- |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
- |
| Cl.23 of IS 302-2-30:2007 &IS:302-1:2008(Internal Wiring) |
- |
200 |
|
- |
| Cl.23 of IS 302-2-30:2007 &IS:302-1:2008(Internal Wiring) |
- |
0 |
|
- |
| Cl.23 of IS 302-2-30:2007 &IS:302-1:2008(Internal Wiring) |
- |
0 |
|
- |
| Cl.23 of IS 302-2-30:2007 &IS:302-1:2008(Internal Wiring) |
- |
0 |
|
- |
| Cl.23 of IS 302-2-30:2007 &IS:302-1:2008(Internal Wiring) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
200 |
|
- |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
200 |
|
- |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
| Cl.26 of IS 302-2-30:2007 &IS:302-1:2008(Terminal for External Conductors) |
- |
200 |
|
- |
| Cl.27 of IS 302-2-30:2007 &IS:302-1:2008(Provision for Earthing) |
- |
500 |
|
- |
| Cl.27 of IS 302-2-30:2007 &IS:302-1:2008(Provision for Earthing) |
- |
0 |
|
- |
| Cl.28 of IS 302-2-30:2007 &IS:302-1:2008(Screws and Connections) |
- |
200 |
|
- |
| Cl.29 of IS 302-2-30:2007 &IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation.) |
- |
200 |
|
- |
| Cl.29 of IS 302-2-30:2007 &IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation.) |
- |
0 |
|
- |
| Cl.30 of IS 302-2-30:2007 &IS:302-1:2008(Resistance to Heat and Fire.) |
- |
200 |
|
- |
| Cl.30 of IS 302-2-30:2007 &IS:302-1:2008(Resistance to Heat and Fire.) |
- |
0 |
|
- |
| Cl.31 of IS 302-2-30:2007 &IS:302-1:2008(Resistance to Rusting) |
- |
200 |
|
- |
| Cl.7 of IS 369:2019(Dimensions) |
- |
500 |
|
- |
| Cl.7 of IS 369:2019(Dimensions) |
- |
0 |
|
- |
| Cl.7 of IS 369:2019(Dimensions) |
- |
0 |
|
- |
| Cl.8 of IS 369:2019(Temperature rises of air-outlet grilles and external surfaces) |
- |
700 |
|
- |
| Cl.8 of IS 369:2019(Temperature rises of air-outlet grilles and external surfaces) |
- |
700 |
|
- |
| Cl.8 of IS 369:2019(Temperature rises of air-outlet grilles and external surfaces) |
- |
800 |
|
- |
| Cl.9 of IS 369:2019(Temperature rises of surfaces surrounding the heater) |
- |
800 |
|
- |
| Cl.9 of IS 369:2019(Temperature rises of surfaces surrounding the heater) |
- |
0 |
|
- |
| Cl.9 of IS 369:2019(Temperature rises of surfaces surrounding the heater) |
- |
0 |
|
- |
| Cl.9 of IS 369:2019(Temperature rises of surfaces surrounding the heater) |
- |
0 |
|
- |
| Cl.9 of IS 369:2019(Temperature rises of surfaces surrounding the heater) |
- |
0 |
|
- |
| Cl.9 of IS 369:2019(Temperature rises of surfaces surrounding the heater) |
- |
0 |
|
- |
| Cl.10 of IS 369:2019(Warming-up time of the heater) |
- |
700 |
|
- |
| Cl.11 of IS 369:2019(Stability of room temperature) |
- |
700 |
|
- |
| Cl.11 of IS 369:2019(Stability of room temperature) |
- |
0 |
|
- |
| Cl.11 of IS 369:2019(Stability of room temperature) |
- |
0 |
|
- |
| Cl.11 of IS 369:2019(Stability of room temperature) |
- |
0 |
|
- |
| Cl.12 of IS 369:2019(Set-back) |
- |
700 |
|
- |
| Cl.13 of IS 369:2019(Frost protection temperature) |
- |
500 |
|
- |
| Cl.14 of IS 369:2019(Inrush current) |
- |
500 |
|
- |
| Cl.15 of IS 369:2019(Effect of radiant heat) |
- |
500 |
|
- |
| Cl.15 of IS 369:2019(Effect of radiant heat) |
- |
500 |
|
- |
| Cl.15 of IS 369:2019(Effect of radiant heat) |
- |
0 |
|
- |
| Cl.16 of IS 369:2019(Usable power) |
- |
500 |
|
- |
| Cl.17 of IS 302-2-30:2007(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
|
03 Oct, 2027 |
- Included.w.e.f.26.11.2024 |
| 18 |
IS 368 (2014) |
Electric immersion water heaters - Specification (Fifth Revision) |
----- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 of IS 302-‐2-‐201:2008(Classification) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
- |
| Cl.8 of IS 302‐2-201: 2008(Protection Against Access to Live Parts) |
- |
500 |
|
- |
| Cl.10 of IS 302‐2‐201:2008(Power Input and Current ) |
- |
2000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1500 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
50 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
50 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
50 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
50 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
50 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
50 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
50 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
50 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
50 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
50 |
|
- |
| Cl. 12 of IS 368:2014(Operation under overload conditions of appliances with heating elements) |
- |
500 |
|
- |
| Cl.13 of IS 302-2-201: 2008(Leakage Current & Electric Strength at Operating Temperature) |
- |
1500 |
|
- |
| Cl.13 of IS 302-2-201: 2009(Leakage Current & Electric Strength at Operating Temperature) |
- |
50 |
|
- |
| Cl.14 of IS 302‐2-201:2008(Transient Over Voltages ) |
- |
1000 |
|
- |
| Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
1000 |
|
- |
| Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
0 |
|
- |
| Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
1500 |
|
- |
| Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
50 |
|
- |
| Cl.17 of IS 302‐2-201: 2008(Overload Protection of Transformers & Associated Circuits) |
- |
500 |
|
- |
| Cl.18 of IS 368:2014(Endurance) |
- |
1000 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1500 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
50 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
50 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
50 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
50 |
|
- |
| Cl.20 of IS 302-2-201: 2008(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
500 |
|
- |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
50 |
|
- |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
50 |
|
- |
| Cl.22 of IS 302-2-201: 2008(Construction) |
- |
500 |
|
- |
| Cl.22 of IS 302-2-201: 2008(Construction) |
- |
50 |
|
- |
| Cl.22 of IS 302-2-201: 2008(Construction) |
- |
50 |
|
- |
| Cl.22 of IS 302-2-201: 2008(Construction) |
- |
50 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
500 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
50 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
50 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
50 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
50 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
50 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
50 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
50 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
50 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
500 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
50 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
50 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
50 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
50 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
50 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
50 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
50 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
50 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
500 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
50 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
50 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
50 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
50 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
50 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
50 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
50 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
50 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
50 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
50 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
50 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
50 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
50 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
50 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
50 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
50 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
50 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
50 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
50 |
|
- |
| Cl.26 of IS 302-2-201: 2008(Terminals for External Conductors) |
- |
500 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
50 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
50 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
50 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
50 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
50 |
|
- |
| Cl.28 of IS 302-2-201: 2008(Screws & Connections ) |
- |
500 |
|
- |
| Cl.29 of IS 302-2‐201:2008(Clearances, Creepage Distances and Solid Insulation ) |
- |
1000 |
|
- |
| Cl.29 of IS 302-2‐201:2008(Clearances, Creepage Distances and Solid Insulation ) |
- |
50 |
|
- |
| Cl.30 of IS 302-2‐201:2008(Resistance to Heat and Fire ) |
- |
700 |
|
- |
| Cl.30 of IS 302-2‐201:2008(Resistance to Heat and Fire ) |
- |
100 |
|
- |
| Cl.31 of IS 302-2-201:2008(Resistance of Rusting ) |
- |
500 |
|
- |
| 4(GENERAL REQUIREMENT) |
- |
50 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
50 |
|
- |
|
03 Oct, 2027 |
- Included.w.e.f.09.11.2024 Exclusion 32 (RADIATION, TOXICITY AND SIMILAR HAZARDS) 19.11.4.1 to 19.11.4.5 (EMI/EMC) |
| 19 |
IS 4159 (2021) |
Mineral Filled Sheathed Heating Elements |
---- |
14800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| "Cl. 6 IS 4159:2021"(Classification) |
- |
100 |
|
- |
| "Cl. 8 IS 4159:2021"(Protection against access to live parts) |
- |
500 |
|
- |
| "Cl. 9 IS 4159:2021"(Starting of motor operated appliances) |
- |
100 |
|
- |
| "Cl. 10 IS 4159:2021"(Power Input and Current) |
- |
1500 |
|
- |
| "Cl. 11 IS 4159:2021"(Heating) |
- |
1000 |
|
- |
| "Cl. 13 IS 4159:2021"(Leakage Current & Electrical Strength at Operating Temperature) |
- |
1000 |
|
- |
| "Cl. 14 IS 4159:2021"(Transient Over Voltage) |
- |
500 |
|
- |
| "Cl. 15 IS 4159:2021"(Moisture Resistance) |
- |
500 |
|
- |
| "Cl. 16 IS 4159:2021"(Leakage Current and Electric strength) |
- |
1000 |
|
- |
| "Cl. 17 IS 4159:2021"(Overload protection of transformers and associated circuits.) |
- |
100 |
|
- |
| "Cl. 18 IS 4159:2021"(Endurance) |
- |
500 |
|
- |
| "Cl. 19 IS 4159:2021"(Abnormal Operation) |
- |
500 |
|
- |
| "Cl. 20 IS 4159:2021"(Stability and mechanical Hazards) |
- |
200 |
|
- |
| "Cl. 21 IS 4159:2021"(Mechanical Strength) |
- |
200 |
|
- |
| "Cl. 22 IS 4159:2021"(Construction) |
- |
500 |
|
- |
| "Cl. 23 IS 4159:2021"(Internal Wiring) |
- |
500 |
|
- |
| "Cl. 24 IS 4159:2021"(Components) |
- |
500 |
|
- |
| "Cl. 25 IS 4159:2021"(Supply Connections and External Flexible Cables and Cords) |
- |
200 |
|
- |
| "Cl. 26 IS 4159:2021"(Terminal For External Conductors) |
- |
200 |
|
- |
| "Cl. 27 IS 4159:2021"(Provision For Earthing) |
- |
500 |
|
- |
| "Cl. 28 IS 4159:2021"(Screws and Connections) |
- |
200 |
|
- |
| "Cl. 29 IS 4159:2021"(Creepage Distances, Clearances And Distances Through Insulation) |
- |
500 |
|
- |
| "Cl. 30 IS 4159:2021"(Resistance To Heat, Fire And Tracking) |
- |
500 |
|
- |
| "Cl. 31 IS 4159:2021"(Resistance To Rusting) |
- |
500 |
|
- |
| "Cl. 102 IS 4159:2021"(Leakage and hydrostatic strength (for oil heating elements)) |
- |
50 |
|
- |
| Cl.22.106(CONSTRUCTION) |
- |
100 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
50 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
50 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
50 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
50 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
50 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
50 |
|
- |
| Cl.7.2 of IS 4159:2021(Marking) |
- |
50 |
|
- |
| Cl.7.3 of IS 4159:2021(Marking) |
- |
50 |
|
- |
| Cl.10 of IS 302-1:2008(Power Input & Current) |
- |
0 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
0 |
|
- |
| Cl.11.2 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.11.101 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.18 of IS 4159:2021(Endurance Test) |
- |
50 |
|
- |
| Cl.19.2 of IS 302-1: 2008(Abnormal Operation) |
- |
50 |
|
- |
| Cl.19.3 of IS 302-1: 2008(Abnormal Operation) |
- |
50 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
50 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.22.101 of IS 4159:2021(Construction) |
- |
50 |
|
- |
| Cl.22.102 of IS 4159:2021(Construction) |
- |
50 |
|
- |
| Cl.22.103 of IS 4159:2021(Construction) |
- |
50 |
|
- |
| Cl.22.104 of IS 4159:2021(Construction) |
- |
50 |
|
- |
| Cl.22.105 of IS 4159:2021(Construction) |
- |
50 |
|
- |
| Cl.22.106 of IS 4159:2021(Construction) |
- |
50 |
|
- |
| Cl.22.107 of IS 4159:2021(Construction) |
- |
50 |
|
- |
| Cl.22.108 of IS 4159:2021(Construction) |
- |
50 |
|
- |
| Cl.22.109 of IS 4159:2021(Construction) |
- |
50 |
|
- |
| Cl.22.110 of IS 4159:2021(Construction) |
- |
50 |
|
- |
| Cl.22.111 of IS 4159:2021(Construction) |
- |
50 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
1000 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
0 |
|
- |
| Cl.28.1 & IS 302-1: 2008(Screws & Connection) |
- |
100 |
|
- |
| Cl.28.4 IS 302-1: 2008(Screws & Connection) |
- |
100 |
|
- |
| Cl. 29.1 & IS 302-1: 2008(Creepage Distances & Clearances) |
- |
500 |
|
- |
| Cl. 29.2 & IS 302-1: 2009(Creepage Distances & Clearances) |
- |
50 |
|
- |
| "Cl. 6 IS 4159:2021"(Classification) |
- |
100 |
|
- |
| "Cl. 8 IS 4159:2021"(Protection against access to live parts) |
- |
500 |
|
- |
| "Cl. 9 IS 4159:2021"(Starting of motor operated appliances) |
- |
0 |
|
- |
| "Cl. 10 IS 4159:2021"(Power Input and Current) |
- |
1200 |
|
- |
| "Cl. 11 IS 4159:2021"(Heating) |
- |
1000 |
|
- |
| "Cl. 13 IS 4159:2021"(Leakage Current & Electrical Strength at Operating Temperature) |
- |
1000 |
|
- |
| "Cl. 14 IS 4159:2021"(Transient Over Voltage) |
- |
500 |
|
- |
| "Cl. 15 IS 4159:2021"(Moisture Resistance) |
- |
500 |
|
- |
| "Cl. 16 IS 4159:2021"(Leakage Current and Electric strength) |
- |
500 |
|
- |
| "Cl. 17 IS 4159:2021"(Overload protection of transformers and associated circuits.) |
- |
200 |
|
- |
| "Cl. 18 IS 4159:2021"(Endurance) |
- |
0 |
|
- |
| "Cl. 19 IS 4159:2021"(Abnormal Operation) |
- |
500 |
|
- |
| "Cl. 20 IS 4159:2021"(Stability and mechanical Hazards) |
- |
200 |
|
- |
| "Cl. 21 IS 4159:2021"(Mechanical Strength) |
- |
200 |
|
- |
| "Cl. 22 IS 4159:2021"(Construction) |
- |
500 |
|
- |
| "Cl. 23 IS 4159:2021"(Internal Wiring) |
- |
500 |
|
- |
| "Cl. 24 IS 4159:2021"(Components) |
- |
200 |
|
- |
| "Cl. 25 IS 4159:2021"(Supply Connections and External Flexible Cables and Cords) |
- |
500 |
|
- |
| "Cl. 26 IS 4159:2021"(Terminal For External Conductors) |
- |
200 |
|
- |
| "Cl. 27 IS 4159:2021"(Provision For Earthing) |
- |
500 |
|
- |
| "Cl. 28 IS 4159:2021"(Screws and Connections) |
- |
200 |
|
- |
| "Cl. 29 IS 4159:2021"(Creepage Distances, Clearances And Distances Through Insulation) |
- |
500 |
|
- |
| "Cl. 30 IS 4159:2021"(Resistance To Heat, Fire And Tracking) |
- |
500 |
|
- |
| "Cl. 31 IS 4159:2021"(Resistance To Rusting) |
- |
200 |
|
- |
| "Cl. 102 IS 4159:2021"(Leakage and hydrostatic strength (for oil heating elements)) |
- |
500 |
|
- |
| Cl.22.106(CONSTRUCTION) |
- |
50 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
200 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.2 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.3 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.10 of IS 302-1:2008(Power Input & Current) |
- |
0 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
0 |
|
- |
| Cl.11.2 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.11.101 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.18 of IS 4159:2021(Endurance Test) |
- |
500 |
|
- |
| Cl.19.2 of IS 302-1: 2008(Abnormal Operation) |
- |
500 |
|
- |
| Cl.19.3 of IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.22.101 of IS 4159:2021(Construction) |
- |
500 |
|
- |
| Cl.22.102 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.103 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.104 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.105 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.106 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.107 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.108 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.109 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.110 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.111 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
500 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
0 |
|
- |
| Cl.28.1 & IS 302-1: 2008(Screws & Connection) |
- |
200 |
|
- |
| Cl.28.4 IS 302-1: 2008(Screws & Connection) |
- |
0 |
|
- |
| Cl. 29.1 & IS 302-1: 2008(Creepage Distances & Clearances) |
- |
500 |
|
- |
| Cl. 29.2 & IS 302-1: 2009(Creepage Distances & Clearances) |
- |
0 |
|
- |
|
03 Oct, 2027 |
- Included.w.e.f.26.11.2024 Exclusion - 19.11.4.1 to 19.11.4.7 (EMI/EMC) |
| 20 |
IS 302 : Part 2 : Sec 14 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision) |
----- |
15400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
50 |
|
- |
| 6(Classification- IS 302-1) |
- |
50 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
200 |
|
- |
| 7.101(Marking) |
- |
50 |
|
- |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
500 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
1000 |
|
- |
| 11(Heating, IS 302-1) |
- |
500 |
|
- |
| 11(Heating, IS 302-1) |
- |
50 |
|
- |
| 11(Heating, IS 302-1) |
- |
50 |
|
- |
| 11(Heating, IS 302-1) |
- |
50 |
|
- |
| 11(Heating, IS 302-1) |
- |
50 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
50 |
|
- |
| 14(Transient Over Voltages, IS 302-1) |
- |
500 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
500 |
|
- |
| 15.2(Moisture Resistance, IS 302-1) |
- |
500 |
|
- |
| 15(Moisture Resistance, IS 302-1) |
- |
50 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1000 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
100 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
150 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
50 |
|
- |
| 19.7(Abnormal Operation, IS 302-1) |
- |
500 |
|
- |
| 19.8(Abnormal Operation, IS 302-1) |
- |
50 |
|
- |
| 19.9(Abnormal Operation, IS 302-1) |
- |
50 |
|
- |
| 19.1(Abnormal Operation, IS 302-1) |
- |
50 |
|
- |
| 19.101(Abnormal Operation) |
- |
50 |
|
- |
| 19.102(Abnormal Operation) |
- |
50 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
50 |
|
- |
| 20.101(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.102(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.103(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.104(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.105(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.106(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.107(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.108(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.109(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.110(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.111(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.112(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.113(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.114(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.115(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.116(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
500 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
50 |
|
- |
| 22(Construction, IS 302-1) |
- |
500 |
|
- |
| 22.101(Construction) |
- |
50 |
|
- |
| 22.102(Construction) |
- |
50 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 23.10(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 24.1(Components, IS 302-1) |
- |
500 |
|
- |
| 24.2(Components, IS 302-1) |
- |
50 |
|
- |
| 24.5(Components, IS 302-1) |
- |
50 |
|
- |
| 24.6(Components, IS 302-1) |
- |
50 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
50 |
|
- |
| 27(Provision for Earthing, IS 302-1) |
- |
500 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
50 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
50 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
50 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
50 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
100 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
100 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
50 |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
500 |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
50 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
500 |
|
- |
| 4(GENERAL REQUIREMENTS) |
- |
50 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
50 |
|
- |
| 27(Provision for Earthing) |
- |
50 |
|
- |
| 29(Clearances, Creepage distances and Solid Insulation) |
- |
50 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
- |
| 6(Classification- IS 302-1 ) |
- |
50 |
|
- |
| 6(Classification- IS 302-1) |
- |
50 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
50 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
200 |
|
- |
| 7.101(Marking) |
- |
50 |
|
- |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
500 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
1000 |
|
- |
| 11(Heating, IS 302-1) |
- |
500 |
|
- |
| 11(Heating, IS 302-1) |
- |
50 |
|
- |
| 11(Heating, IS 302-1) |
- |
50 |
|
- |
| 11(Heating, IS 302-1) |
- |
50 |
|
- |
| 11(Heating, IS 302-1) |
- |
50 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
50 |
|
- |
| 14(Transient Over Voltages, IS 302-1) |
- |
500 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
500 |
|
- |
| 15.2(Moisture Resistance, IS 302-1) |
- |
500 |
|
- |
| 15(Moisture Resistance, IS 302-1) |
- |
50 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1000 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
100 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
150 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
50 |
|
- |
| 19.7(Abnormal Operation, IS 302-1) |
- |
500 |
|
- |
| 19.8(Abnormal Operation, IS 302-1) |
- |
50 |
|
- |
| 19.9(Abnormal Operation, IS 302-1) |
- |
50 |
|
- |
| 19.1(Abnormal Operation, IS 302-1) |
- |
50 |
|
- |
| 19.101(Abnormal Operation) |
- |
50 |
|
- |
| 19.102(Abnormal Operation) |
- |
50 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
50 |
|
- |
| 20.101(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.102(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.103(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.104(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.105(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.106(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.107(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.108(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.109(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.110(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.111(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.112(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.113(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.114(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.115(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.116(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
500 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
50 |
|
- |
| 22(Construction, IS 302-1) |
- |
500 |
|
- |
| 22.101(Construction) |
- |
50 |
|
- |
| 22.102(Construction) |
- |
50 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 23.10(Internal Wiring, IS 302-1) |
- |
50 |
|
- |
| 24.1(Components, IS 302-1) |
- |
500 |
|
- |
| 24.2(Components, IS 302-1) |
- |
50 |
|
- |
| 24.5(Components, IS 302-1) |
- |
50 |
|
- |
| 24.6(Components, IS 302-1) |
- |
50 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
50 |
|
- |
| 27(Provision for Earthing, IS 302-1) |
- |
500 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
50 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
50 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
50 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
50 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
100 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
100 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
50 |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
500 |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
50 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
500 |
|
- |
| 4(GENERAL REQUIREMENTS) |
- |
50 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
50 |
|
- |
| 27(Provision for Earthing) |
- |
50 |
|
- |
| 29(Clearances, Creepage distances and Solid Insulation) |
- |
50 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
- |
|
03 Oct, 2027 |
- Included w.e.f.18.11.2024
Exclusion
32 (Radiation, Toxicity and similar Hazard IS 302-1)
19.11.4.1 to 19.11.4.5 (EMI/EMC) |
| 21 |
IS 302 : Part 2 : Sec 23 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 23 appliances for skin or hair care (First Revision) |
----- |
22000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
1000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
1500 |
|
- |
| 28(Screws & Connection) |
- |
500 |
|
- |
| 27(Provision For Earthing) |
- |
1500 |
|
- |
| 26(Terminals For External Conductors) |
- |
500 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
500 |
|
- |
| 24(Component) |
- |
500 |
|
- |
| 23(Internal wiring) |
- |
500 |
|
- |
| 22(Construction) |
- |
500 |
|
- |
| 21(Mechanical strength) |
- |
500 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 19(Abnormal Operation) |
- |
1500 |
|
- |
| 18(Endurance) |
- |
500 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
500 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
1000 |
|
- |
| 15(Moisture Resistance) |
- |
1000 |
|
- |
| 14(Transient Over Voltage) |
- |
1000 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
1000 |
|
- |
| 11(Temperature Rise/Heating) |
- |
1500 |
|
- |
| 10(Power Input
& Current) |
- |
2500 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
500 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
500 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
500 |
|
- |
| 6(Classification) |
- |
500 |
|
- |
| 22.32(CONSTRUCTION) |
- |
500 |
|
- |
|
03 Oct, 2027 |
- Included.w.e.f.07.11.2024 Exclusion 32 (RADIATION, TOXICITY AND SIMILAR HAZARDS) 19.11.4.1 to 19.11.4.5 (EMI/EMC) |
| 22 |
IS 302 : Part 2 : Sec 201 (2008) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 201 electric immersion water heaters (First Revision) |
----- |
13500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 of IS 302-‐2-‐201:2008(Classification) |
- |
200 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
200 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.8 of IS 302‐2-201: 2008(Protection Against Access to Live Parts) |
- |
500 |
|
- |
| Cl.10 of IS 302‐2‐201:2008(Power Input and Current ) |
- |
1500 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.13 of IS 302-2-201: 2008(Leakage Current & Electric Strength at Operating Temperature) |
- |
1000 |
|
- |
| Cl.14 of IS 302‐2-201:2008(Transient Over Voltages ) |
- |
500 |
|
- |
| Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
1000 |
|
- |
| Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
0 |
|
- |
| Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
1000 |
|
- |
| Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
0 |
|
- |
| Cl.17 of IS 302‐2-201: 2008(Overload Protection of Transformers & Associated Circuits) |
- |
500 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1000 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
0 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
0 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
0 |
|
- |
| Cl.20 of IS 302-2-201: 2008(Stability & Mechanical Hazards) |
- |
200 |
|
- |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
200 |
|
- |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
0 |
|
- |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-201: 2008(Construction) |
- |
200 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
200 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
0 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
0 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
0 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
0 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
0 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
0 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
0 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
200 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
500 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.26 of IS 302-2-201: 2008(Terminals for External Conductors) |
- |
200 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1500 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
0 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
0 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
0 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
0 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
0 |
|
- |
| Cl.28 of IS 302-2-201: 2008(Screws & Connections ) |
- |
200 |
|
- |
| Cl.29 of IS 302-2‐201:2008(Clearances, Creepage Distances and Solid Insulation ) |
- |
500 |
|
- |
| Cl.30 of IS 302-2‐201:2008(Resistance to Heat and Fire ) |
- |
500 |
|
- |
| Cl.31 of IS 302-2-201:2008(Resistance of Rusting ) |
- |
500 |
|
- |
| 4(GENERAL REQUIREMENTS) |
- |
100 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
100 |
|
- |
| Cl.6 of IS 302-‐2-‐201:2008(Classification) |
- |
200 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
200 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
0 |
|
- |
| Cl.8 of IS 302‐2-201: 2008(Protection Against Access to Live Parts) |
- |
500 |
|
- |
| Cl.10 of IS 302‐2‐201:2008(Power Input and Current ) |
- |
1500 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
0 |
|
- |
| Cl.13 of IS 302-2-201: 2008(Leakage Current & Electric Strength at Operating Temperature) |
- |
1000 |
|
- |
| Cl.14 of IS 302‐2-201:2008(Transient Over Voltages ) |
- |
500 |
|
- |
| Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
1000 |
|
- |
| Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
0 |
|
- |
| Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
1000 |
|
- |
| Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
0 |
|
- |
| Cl.17 of IS 302‐2-201: 2008(Overload Protection of Transformers & Associated Circuits) |
- |
500 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1000 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
0 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
0 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
0 |
|
- |
| Cl.20 of IS 302-2-201: 2008(Stability & Mechanical Hazards) |
- |
200 |
|
- |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
200 |
|
- |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
0 |
|
- |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
0 |
|
- |
| Cl.22 of IS 302-2-201: 2008(Construction) |
- |
200 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
200 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
0 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
0 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
0 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
0 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
0 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
0 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
0 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
200 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
0 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
| Cl.26 of IS 302-2-201: 2008(Terminals for External Conductors) |
- |
200 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
0 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
0 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
0 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
0 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
0 |
|
- |
| Cl.28 of IS 302-2-201: 2008(Screws & Connections ) |
- |
200 |
|
- |
| Cl.29 of IS 302-2‐201:2008(Clearances, Creepage Distances and Solid Insulation ) |
- |
500 |
|
- |
| Cl.30 of IS 302-2‐201:2008(Resistance to Heat and Fire ) |
- |
500 |
|
- |
| Cl.31 of IS 302-2-201:2008(Resistance of Rusting ) |
- |
500 |
|
- |
| 4(GENERAL REQUIREMENTS) |
- |
100 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
100 |
|
- |
|
03 Oct, 2027 |
- Included.w.e.f.07.11.2024 Exclusion 32 (RADIATION, TOXICITY AND SIMILAR HAZARDS) 19.11.4.1 to 19.11.4.5 (EMI/EMC) |
| 23 |
IS 302 : Part 2 : Sec 13 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 13 frying pans, deep fat fryers and similar appliances |
----- |
24000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30(Resistance to Heat, Fire and Tracking) |
- |
1000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
500 |
|
- |
| 28(Screws & Connections) |
- |
500 |
|
- |
| 27(Provision For Earthing) |
- |
1500 |
|
- |
| 26(Terminals For External Conductors) |
- |
500 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
500 |
|
- |
| 24(Components) |
- |
500 |
|
- |
| 23(Internal wiring) |
- |
500 |
|
- |
| 22(Construction) |
- |
500 |
|
- |
| 21(Mechanical strength) |
- |
500 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 19(Abnormal Operation) |
- |
2000 |
|
- |
| 18(Endurance) |
- |
100 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
500 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
1500 |
|
- |
| 15(Moisture Resistance) |
- |
3000 |
|
- |
| 14(Transient Over Voltage) |
- |
1000 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
1500 |
|
- |
| 11(Temperature Rise/Heating) |
- |
2000 |
|
- |
| 10(Power Input) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
200 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
1000 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
500 |
|
- |
| 6(Classification) |
- |
500 |
|
- |
| 5(Rating) |
- |
200 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30(Resistance to Heat, Fire and Tracking) |
- |
1000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
500 |
|
- |
| 28(Screws & Connections) |
- |
500 |
|
- |
| 27(Provision For Earthing) |
- |
1500 |
|
- |
| 26(Terminals For External Conductors) |
- |
500 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
500 |
|
- |
| 24(Components) |
- |
500 |
|
- |
| 23(Internal wiring) |
- |
500 |
|
- |
| 22(Construction) |
- |
500 |
|
- |
| 21(Mechanical strength) |
- |
500 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 19(Abnormal Operation) |
- |
2000 |
|
- |
| 18(Endurance) |
- |
100 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
500 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
1500 |
|
- |
| 15(Moisture Resistance) |
- |
3000 |
|
- |
| 14(Transient Over Voltage) |
- |
1000 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
1500 |
|
- |
| 11(Temperature Rise/Heating) |
- |
2000 |
|
- |
| 10(Power Input) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
200 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
1000 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
500 |
|
- |
| 6(Classification) |
- |
500 |
|
- |
| 5(Rating) |
- |
200 |
|
- |
|
03 Oct, 2027 |
- Included w.e.f.18.11.2024
Exclusion
32 (Radiation ,Toxicity and similar hazards)
19.11.4.1 to 19.11.4.7 (EMI/EMC) |
| 24 |
IS 2082 (2018) |
Stationary storage type electric water heaters - Specification (Fifth Revision) |
- |
22000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 7(Marking) |
- |
1250 |
|
-- |
| 6(Classification ) |
- |
1250 |
|
-- |
| 6(Classification ) |
- |
1250 |
|
-- |
| (Cl.8 of IS 302-2-21:2011)(Protection Against Access to Live Parts) |
- |
500 |
|
-- |
| (Cl.10 of IS 302-2-21: 2011)(Power Input & Current) |
- |
1000 |
|
-- |
| (Cl.11 of 302-2-21:2011)(Heating) |
- |
1000 |
|
-- |
| (Cl.11 of 302-2-21:2011)(Heating) |
- |
1000 |
|
-- |
| (Cl.11 of 302-2-21:2011)(Heating) |
- |
1000 |
|
-- |
| (Cl.13 of IS 302-2-21:2011)(Leakage Current ) |
- |
500 |
|
-- |
| (Cl.13 of IS 302-2-21:2011)(Electrical Strength at Operating Temperature) |
- |
500 |
|
-- |
| (Cl.15 of IS 302-2-21-2011)(Moisture Resistance) |
- |
1000 |
|
-- |
| (Cl.15 of IS 302-2-21-2011)(Moisture Resistance) |
- |
1000 |
|
-- |
| (Cl.15 of IS 302-2-21-2011)(Moisture Resistance) |
- |
1000 |
|
-- |
| (Cl.17 of IS 302-2-21:2011)(Overload protection of transformers & associated circuits) |
- |
2000 |
|
-- |
| (Cl.19 of IS 302-2-21:2011)(Abnormal Operation) |
- |
1000 |
|
-- |
| (Cl.19 of IS 302-2-21:2011)(Abnormal Operation) |
- |
1000 |
|
-- |
| (Cl.19 of IS 302-2-21:2011)(Abnormal Operation) |
- |
1000 |
|
-- |
| (Cl.19 of IS 302-2-21:2011)(Abnormal Operation) |
- |
1000 |
|
-- |
| (Cl.20 of IS 302-2-21:2011)(Stability & Mechanical Hazards) |
- |
500 |
|
-- |
| (Cl.21ofIS302-2-21:2011)(Mechanical strength) |
- |
750 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1500 |
|
-- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
500 |
|
-- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
500 |
|
-- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
500 |
|
-- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
500 |
|
-- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
500 |
|
-- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
500 |
|
-- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
500 |
|
-- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
500 |
|
-- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
500 |
|
-- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
500 |
|
-- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
500 |
|
-- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
500 |
|
-- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
500 |
|
-- |
| (Cl.24ofIS302-221:2011)(Component) |
- |
750 |
|
-- |
| (Cl.24ofIS302-221:2011)(Component) |
- |
750 |
|
-- |
| (Cl.24ofIS302-221:2011)(Component) |
- |
750 |
|
-- |
| (Cl.24ofIS302-221:2011)(Component) |
- |
750 |
|
-- |
| (Cl.24ofIS302-221:2011)(Component) |
- |
750 |
|
-- |
| (Cl.24ofIS302-221:2011)(Component) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
750 |
|
-- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
750 |
|
-- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
750 |
|
-- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
750 |
|
-- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
750 |
|
-- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
750 |
|
-- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
750 |
|
-- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
750 |
|
-- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
750 |
|
-- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
750 |
|
-- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
750 |
|
-- |
| (Cl.27 of IS 302-2-21:2011)(Provision for Earthing) |
- |
500 |
|
-- |
| (Cl.27 of IS 302-2-21:2011)(Provision for Earthing) |
- |
500 |
|
-- |
| (Cl.27 of IS 302-2-21:2011)(Provision for Earthing) |
- |
500 |
|
-- |
| (Cl.27 of IS 302-2-21:2011)(Provision for Earthing) |
- |
500 |
|
-- |
| (Cl.27 of IS 302-2-21:2011)(Provision for Earthing) |
- |
500 |
|
-- |
| (Cl.27 of IS 302-2-21:2011)(Provision for Earthing) |
- |
500 |
|
-- |
| (Cl.28 of IS 302-2-21:2011)(Screws & Connections) |
- |
500 |
|
-- |
| (Cl.29ofIS302-2-21:2011)(Clearances, Creepage Distances and Solid Insulation) |
- |
500 |
|
-- |
| (Cl.30 of IS 302-2-21:2011)(Resistance to Heat & Fire) |
- |
1500 |
|
-- |
| (Cl.30 of IS 302-2-21:2011)(Resistance to Heat & Fire) |
- |
1500 |
|
-- |
| (Cl.31 of IS 302-2-21:2011)(Resistance to Rusting) |
- |
750 |
|
-- |
| (Cl.15 of IS 2082:2018)(Verification of the Rated Capacity) |
- |
2250 |
|
-- |
| (Cl.16 of IS 2082:2018)(Standing Loss per 24 Hours) |
- |
6000 |
|
-- |
| (Cl.17 of IS 2082:2018)(Hot Water Output) |
- |
3000 |
|
-- |
| (Cl.18 of IS 2082:2018)( Reheating Time) |
- |
2500 |
|
-- |
| (Cl.19 of IS 2082:2018)(Mixing Factor) |
- |
1250 |
|
-- |
| (Cl.20 of IS 2082:2018)(Deviation of Dial Calibration) |
- |
1500 |
|
-- |
| (Cl.21 of IS 2082:2018)(Cyclic Temperature Variation) |
- |
1000 |
|
-- |
| (Cl.22 of IS 2082:2018)(Finish) |
- |
1000 |
|
-- |
| Cl.22 of IS 2082:2018(Finish) |
- |
1000 |
|
-- |
| Cl.21 of IS 2082:2018(Cyclic Temperature Variation) |
- |
1000 |
|
-- |
| Cl.20 of IS 2082:2018(Deviation of Dial Calibration) |
- |
1500 |
|
-- |
| Cl.19 of IS 2082:2018(Mixing Factor) |
- |
1250 |
|
-- |
| Cl.18 of IS 2082:2018( Reheating Time) |
- |
2500 |
|
-- |
| Cl.17 of IS 2082:2018(Hot Water Output) |
- |
3000 |
|
-- |
| Cl.16 of IS 2082:2018(Standing Loss per 24 Hours) |
- |
6000 |
|
-- |
| Cl.15 of IS 2082:2018(Verification of the Rated Capacity) |
- |
2250 |
|
-- |
| Cl.31 of IS 302-2-21:2018(Resistance to Rusting) |
- |
375 |
|
-- |
| Cl.30.2 of IS 302-1:2008(Resistance to Heat & Fire : Glow wire test ) |
- |
750 |
|
-- |
| Cl.30.1 of IS 302-1:2008(Resistance to Heat & Fire : Ball pressure test ) |
- |
750 |
|
-- |
| Cl.29.2 of IS 302-1:2008(Clearances, Creepage Distances and Solid Insulation : Creepage distance ) |
- |
250 |
|
-- |
| Cl.29.1 of IS 302-1:2008(Clearances, Creepage Distances and Solid Insulation : Clearance distance ) |
- |
250 |
|
-- |
| Cl.28 of IS 302-2-21:2018(Screws & Connections) |
- |
500 |
|
-- |
| Cl.27.5 of IS 302-1:2008(Provision for Earthing : ECR ) |
- |
250 |
|
-- |
| Cl.27 of IS 302-2-21:2018(Provision for Earthing) |
- |
250 |
|
-- |
| Cl.26 of IS 302-2-21: 2018(Terminals for External Conductors) |
- |
750 |
|
-- |
| Cl.25.18 of IS 302-1:2008(Supply Connection & External Flexible Cords) |
- |
90 |
|
-- |
| Cl.25.15 of IS 302-1:2008(Supply Connection & External Flexible Cords : Cord grip test - displacement ) |
- |
90 |
|
-- |
| Cl.25.15 of IS 302-1:2008(Supply Connection & External Flexible Cords : Cord grip test ) |
- |
90 |
|
-- |
| Cl.25.12 of IS 302-1:2008(Supply Connection & External Flexible Cords : Moulding of supply cord ) |
- |
90 |
|
-- |
| Cl.25.10 of IS 302-1:2008(Supply Connection & External Flexible Cords : Colour of Earthing conductor ) |
- |
90 |
|
-- |
| Cl.25.8 of IS 302-2-21:2018(Supply Connection & External Flexible Cords : Resistance of supply cord ) |
- |
90 |
|
-- |
| Cl.25.5 of IS 302-1:2008(Supply Connection & External Flexible Cords : Type of attachment ) |
- |
90 |
|
-- |
| Cl.25 of IS 302-2-21:2018(Supply Connection & External Flexible Cords : connection to the supply mains) |
- |
90 |
|
-- |
| Cl.24.102 of IS 302-221:2018(Component : Operation of thermal cut-out ) |
- |
250 |
|
-- |
| Cl.24.101 of IS302-221:2018(Component : Location of non self reseting thermal cut out ) |
- |
250 |
|
-- |
| Cl.24of IS 302-221:2018(Component : Relevent Indian standards ) |
- |
250 |
|
-- |
| Cl. 23 of IS 302-1:2008(Internal Wiring : color identification for earthing conductor
) |
- |
250 |
|
-- |
| Cl. 23 of IS 302-1:2008(Internal Wiring
) |
- |
250 |
|
-- |
| Cl.22.111 of
IS 302-2-21:2018(Construction : Resistance to vacuum ) |
- |
55 |
|
-- |
| Cl.22.110 of
IS 302-2-21:2018(Construction : meterial of connections ) |
- |
55 |
|
-- |
| Cl.22.110 of
IS 302-2-21:2018(Construction : Material of Inner conatiner ) |
- |
55 |
|
-- |
| Cl.22.109 of
IS 302-2-21:2018(Construction : Drain for appliance having a capacity of more than 15 liter) |
- |
55 |
|
-- |
| Cl.22.108 of
IS 302-2-21:2018(Construction : fixing to wall ) |
- |
55 |
|
-- |
| Cl.22.107 of
IS 302-2-21:2018(Construction : Position of Heating elements and thermal control sensor) |
- |
55 |
|
-- |
| Cl.22.106 of
IS 302-2-21:2018(Construction : Operation of thermal cut- out ) |
- |
55 |
|
-- |
| Cl.22.104 of
IS 302-2-21:2018(Construction : Outlet of open outlet heater ) |
- |
55 |
|
-- |
| Cl.22.103 of
IS 302-2-21:2018(Construction : Operation of Pressure relieve devices ) |
- |
55 |
|
-- |
| Cl.22.102 of
IS 302-2-21:2018(Construction : repeated drawing of water temp ) |
- |
55 |
|
-- |
| Cl.22.101 of
IS 302-2-21:2018(Construction : rated pressure of closed water heater ) |
- |
55 |
|
-- |
| Cl.22.47 of
IS 302-2-21:2018 (Construction : Water pressure test ) |
- |
55 |
|
-- |
| Cl.22.44 of
IS 302-1:2008(Construction : Shape and decoration of enclosure) |
- |
55 |
|
-- |
| Cl.22.34, Cl 22.35 of
IS 302-1:2008(Construction : Shaft of operating Knobs ) |
- |
55 |
|
-- |
| Cl.22.33 of
IS 302-1:2008(Construction : Direct contact of liquids ) |
- |
55 |
|
-- |
| Cl 22.26 ,Cl.22.28, Cl 22.29, Cl 22.30 , Cl 22.31, Cl 22.32 of
IS 302-1:2008(Construction : Supplymentry/ double / reinforced insulation for Class II/ Class III appliance ) |
- |
55 |
|
-- |
| Cl.22.18 Of
IS 302-1:2008(Construction : Resistance to corrosion ) |
- |
55 |
|
-- |
| Cl.22.17 of
IS 302-1:2008(Construction : Spacers ) |
- |
55 |
|
-- |
| Cl.22.14 of
IS 302-1:2008(Construction : ragged or sharp edges) |
- |
55 |
|
-- |
| Cl.22.12 of
IS 302-1:2008(Construction : Fixing of Handle, knob, grips, levers and similar parts) |
- |
55 |
|
-- |
| Cl.22.11 of
IS 302-1:2008(Construction : Fixing of non detachable part ) |
- |
55 |
|
-- |
| Cl.22.7 of
IS 302-1:2008(Construction: adequate safeguards against the risk of excessive pressure) |
- |
55 |
|
-- |
| Cl.22.6 of
IS 302-2-21:2018(Construction : Size of drain hole ) |
- |
55 |
|
-- |
| Cl.22.2 of
IS 302-1:2008(Construction : Provision to ensure all pole disconnection ) |
- |
55 |
|
-- |
| Cl.22.1 of
IS 302-1:2008(Construction : IP test ) |
- |
55 |
|
-- |
| Cl.21.2 of IS 302-1:2008(Mechanical strength : prevent penetration by sharp implements. ) |
- |
375 |
|
-- |
| Cl.21.1 of IS 302-1:2008(Mechanical strength : Rough handling in normal use) |
- |
375 |
|
-- |
| Cl.20 of IS 302-1:2008(Stability & Mechanical Hazards) |
- |
500 |
|
-- |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : leakage from container during test) |
- |
200 |
|
-- |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : High Voltage ) |
- |
200 |
|
-- |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : Insulation of the supply cable or cord) |
- |
200 |
|
-- |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : emission of flame or molten metal or poisonous or ignitable gas ) |
- |
200 |
|
-- |
| Cl.16 of IS 302-2-21-2018(Leakage current and Electric strength (After humidity): Electric Strentgh ) |
- |
1500 |
|
-- |
| Cl.16 of IS 302-2-21-2018(Leakage current and Electric strength (After humidity): Leakage current ) |
- |
1500 |
|
-- |
| Cl.15 of IS 302-2-21-2018(Moisture Resistance) |
- |
1000 |
|
-- |
| Cl.13 of IS 302-2-21:2018(3 Strength at Operating Temperature) |
- |
500 |
|
-- |
| Cl.13 of IS 302-2-21:2018(Leakage Current ) |
- |
500 |
|
-- |
| Cl.11 of 302-2-21:2018(Heating : Room Temp.) |
- |
300 |
|
-- |
| Cl.11 of 302-2-21:2018(Heating : Temp of Rubber or PVC insulation of internal and external wiring) |
- |
300 |
|
-- |
| Cl.11 of 302-2-21:2018(Heating : Temp of Walls, ceilings and floor of the test corner ) |
- |
300 |
|
-- |
| Cl.10 of IS 302-2-21: 2018(Power Input & Current) |
- |
1000 |
|
-- |
| Cl.8 of IS 302-2-21:2018(Protection Against Access to Live Parts) |
- |
500 |
|
-- |
| 7.101(Marking : Indifiction of water inlet and water outlet ) |
- |
50 |
|
-- |
| 7.14(Marking : Legibility and durability) |
- |
500 |
|
-- |
| 7.13(Marking : Official language of Instruction ) |
- |
50 |
|
-- |
| 7.11(Marking : Indication of controls ) |
- |
50 |
|
-- |
| 7.8(Marking : Terminals ) |
- |
50 |
|
-- |
| 7.6(Marking : Symbol used ) |
- |
50 |
|
-- |
| 7.1(Marking : Warning for Open- outlet ) |
- |
50 |
|
-- |
| 7.1(Marking : Statement for pressure reducing valve ( For rated pressure less than 0.6 MPa)) |
- |
50 |
|
-- |
| 7.1(Marking : Rated capacity) |
- |
50 |
|
-- |
| 7.1(Marking : Country of manufacture) |
- |
50 |
|
-- |
| 7.1(Marking: IP Number) |
- |
50 |
|
-- |
| 7.1(Marking: Symbol for Class II) |
- |
50 |
|
-- |
| 7.1(Marking: Model or type reference) |
- |
50 |
|
-- |
| 7.1(Marking : Rated power input) |
- |
50 |
|
-- |
| 7.1(Marking : Symbol for nature of supply ) |
- |
50 |
|
-- |
| 4(GENERAL REQUIREMENT) |
- |
1250 |
|
-- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
50 |
|
-- |
| 12(THERMOSTAT SETTING) |
- |
1250 |
|
-- |
| Cl-10(Mounting of the water heater) |
- |
1250 |
|
-- |
| Cl-12(Thermostat setting) |
- |
1250 |
|
-- |
| Cl-13(Measurement of energy consumption) |
- |
2250 |
|
-- |
| Cl-14(Verification of the rated capacity) |
- |
2250 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : Wall ceiling temp. of test corner ) |
- |
200 |
|
-- |
| 7.1(Marking : Statement for a pressure-relief device) |
- |
50 |
|
-- |
| 7.1(Marking : Rated pressure) |
- |
50 |
|
-- |
| 7.1(Marking: Name, trademark or identification mark of manufacturer ) |
- |
50 |
|
-- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
750 |
|
-- |
| Cl.22.6 of
IS 302-1:2008(Construction : Effect of water on 3 insulation ) |
- |
750 |
|
-- |
| 7.1(Marking : Rated Voltage ) |
- |
50 |
|
-- |
| Cl-11(Measurements of stored water temperature) |
- |
750 |
|
-- |
| (Cl.14ofIS302-2-21:2011)(Transient Over Voltages) |
- |
500 |
|
- |
| Cl.14 of IS 302-2-21:2018(Transient Over Voltages) |
- |
500 |
|
- |
|
03 Oct, 2027 |
- - |
| 25 |
IS 302 : Part 2 : Sec 3 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 3 electric iron (First Revision) |
- |
16000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
100 |
|
-- |
| 6(Classification- IS 302-1) |
- |
100 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
60 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
40 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
40 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
40 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
40 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
40 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
40 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
40 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
40 |
|
-- |
| 7.3(Marking- IS 302-1) |
- |
40 |
|
-- |
| 7.4(Marking- IS 302-1) |
- |
40 |
|
-- |
| 7.6(Marking- IS 302-1) |
- |
40 |
|
-- |
| 7.7(Marking- IS 302-1) |
- |
40 |
|
-- |
| 7.8(Marking- IS 302-1) |
- |
40 |
|
-- |
| 7.11(Marking- IS 302-1) |
- |
40 |
|
-- |
| 7.12(Marking- IS 302-1) |
- |
40 |
|
-- |
| 7.13(Marking- IS 302-1) |
- |
40 |
|
-- |
| 7.14(Marking- IS 302-1) |
- |
40 |
|
-- |
| 7.15(Marking- IS 302-1) |
- |
40 |
|
-- |
| 7.101(Marking) |
- |
40 |
|
-- |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
500 |
|
-- |
| 10(Power Input and Current, IS 302-1) |
- |
900 |
|
-- |
| 11(Heating, IS 302-1) |
- |
500 |
|
-- |
| 11(Heating, IS 302-1) |
- |
500 |
|
-- |
| 11(Heating, IS 302-1) |
- |
1000 |
|
-- |
| 11(Heating, IS 302-1) |
- |
1000 |
|
-- |
| 11(Heating, IS 302-1) |
- |
1000 |
|
-- |
| 11(Heating, IS 302-1) |
- |
1000 |
|
-- |
| 11(Heating, IS 302-1) |
- |
1000 |
|
-- |
| 11(Heating, IS 302-1) |
- |
1000 |
|
-- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1000 |
|
-- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
750 |
|
-- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
500 |
|
-- |
| 15.2(Moisture Resistance, IS 302-1) |
- |
500 |
|
-- |
| 15.3(Moisture Resistance, IS 302-1) |
- |
500 |
|
-- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1000 |
|
-- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
1000 |
|
-- |
| 19.4(Abnormal Operation, IS 302-1) |
- |
100 |
|
-- |
| 19.4(Abnormal Operation, IS 302-1) |
- |
100 |
|
-- |
| 19.5(Abnormal Operation, IS 302-1) |
- |
80 |
|
-- |
| 19.5(Abnormal Operation, IS 302-1) |
- |
100 |
|
-- |
| 19.7(Abnormal Operation) |
- |
80 |
|
-- |
| 19.9(Abnormal Operation) |
- |
80 |
|
-- |
| 19.1(Abnormal Operation) |
- |
80 |
|
-- |
| 19.101(Abnormal Operation) |
- |
80 |
|
-- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
250 |
|
-- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
250 |
|
-- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
200 |
|
-- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
200 |
|
-- |
| 21.101(Mechanical Strength, IS 302-2-3) |
- |
100 |
|
-- |
| 22(Construction, IS 302-1) |
- |
80 |
|
-- |
| 22.101(Construction) |
- |
60 |
|
-- |
| 22.102(Construction) |
- |
60 |
|
-- |
| 22.103(Construction) |
- |
60 |
|
-- |
| 22.104(Construction) |
- |
60 |
|
-- |
| 22.105(Construction) |
- |
60 |
|
-- |
| 22.106(Construction) |
- |
60 |
|
-- |
| 22.107(Construction) |
- |
60 |
|
-- |
| 23.1(Internal Wiring, IS 302-1) |
- |
50 |
|
-- |
| 23.2(Internal Wiring, IS 302-1) |
- |
50 |
|
-- |
| 23.3(Internal Wiring, IS 302-1) |
- |
50 |
|
-- |
| 23.4(Internal Wiring, IS 302-1) |
- |
50 |
|
-- |
| 23.5(Internal Wiring, IS 302-1) |
- |
50 |
|
-- |
| 23.6(Internal Wiring, IS 302-1) |
- |
50 |
|
-- |
| 23.7(Internal Wiring, IS 302-1) |
- |
50 |
|
-- |
| 23.8(Internal Wiring, IS 302-1) |
- |
50 |
|
-- |
| 23.9(Internal Wiring, IS 302-1) |
- |
50 |
|
-- |
| 23.10(Internal Wiring, IS 302-1) |
- |
50 |
|
-- |
| 24.1(Components, IS 302-1) |
- |
100 |
|
-- |
| 24.2(Components, IS 302-1) |
- |
100 |
|
-- |
| 24.4(Components, IS 302-1) |
- |
100 |
|
-- |
| 24.5(Components, IS 302-1) |
- |
100 |
|
-- |
| 24.6(Components, IS 302-1) |
- |
100 |
|
-- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
-- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
-- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
-- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
-- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
-- |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
-- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
-- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
-- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
-- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
-- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
-- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
-- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
-- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
-- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
-- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
-- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
-- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
-- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
-- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
-- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
500 |
|
-- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
100 |
|
-- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
100 |
|
-- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
100 |
|
-- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
100 |
|
-- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
500 |
|
-- |
| 28(Screws & Connections, IS 302-1) |
- |
500 |
|
-- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
250 |
|
-- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
250 |
|
-- |
| 30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
-- |
| 30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
-- |
| 31(Resistance of Rusting, IS 302-1) |
- |
500 |
|
-- |
| 4(General requirement) |
- |
50 |
|
-- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
-- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
This clause of Part 1 is applicable. |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
This clause of Part 1 is applicable. |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
This clause of Part 1 is applicable. |
| 18(Endurance) |
- |
0 |
|
This clause of Part 1 is not applicable. |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
50 |
|
-- |
| 19(Abnormal operation) |
- |
500 |
|
-- |
| 25(Supply Connection and External Flexible Cords) |
- |
50 |
|
-- |
| 14(Transient Over Voltages, IS 302-1) |
- |
1000 |
|
- |
|
03 Oct, 2027 |
- Exclusion
32 (Radiation, Toxicity and similar Hazard IS 302-1)
19.11.4.1 to 19.11.4.7 |
| 26 |
IS 4250 (1980) |
Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) |
- |
26000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
50 |
|
-- |
| 6(Classification- IS 302-1) |
- |
50 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
200 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
200 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
-- |
| 7.2(Marking) |
- |
500 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
-- |
| 7.4(Marking) |
- |
500 |
|
-- |
| 7.5(Marking) |
- |
500 |
|
-- |
| 7.6(Marking) |
- |
500 |
|
-- |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
500 |
|
-- |
| 9(Starting, IS 302-1) |
- |
500 |
|
-- |
| 10(Power Input and Current, IS 302-1) |
- |
2000 |
|
-- |
| 11(Heating, IS 302-1) |
- |
2000 |
|
-- |
| 11(Heating, IS 302-1) |
- |
2000 |
|
-- |
| 11(Heating, IS 302-1) |
- |
2000 |
|
-- |
| 11(Heating, IS 302-1) |
- |
2000 |
|
-- |
| 11(Heating, IS 302-1) |
- |
2000 |
|
-- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1250 |
|
-- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
1250 |
|
-- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
1000 |
|
-- |
| 15.2(Moisture Resistance-Spillage test) |
- |
1000 |
|
-- |
| 15(Moisture Resistance, IS 302-1) |
- |
1000 |
|
-- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1250 |
|
-- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
1250 |
|
-- |
| 19(Abnormal Operation, IS 302-1) |
- |
1000 |
|
-- |
| 19(Abnormal Operation, IS 302-1) |
- |
1000 |
|
-- |
| 19(Abnormal Operation, IS 302-1) |
- |
1000 |
|
-- |
| 19(Abnormal Operation, IS 302-1) |
- |
1000 |
|
-- |
| 20(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
-- |
| 20(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
-- |
| 21(Mechanical Strength, IS 302-1) |
- |
750 |
|
-- |
| 21(Mechanical Strength, IS 302-1) |
- |
750 |
|
-- |
| 22.1(Construction, IS 302-1) |
- |
1500 |
|
-- |
| 22.2(Construction) |
- |
1500 |
|
-- |
| 22.3(Construction) |
- |
1500 |
|
-- |
| 22.4(Construction) |
- |
1500 |
|
-- |
| 22.5(Construction) |
- |
1500 |
|
-- |
| 22.6(Construction) |
- |
1500 |
|
-- |
| 22.8(Construction) |
- |
1500 |
|
-- |
| 22.9(Construction) |
- |
1500 |
|
-- |
| 22.1(Construction) |
- |
1500 |
|
-- |
| 23(Internal Wiring, IS 302-1) |
- |
500 |
|
-- |
| 23(Internal Wiring, IS 302-1) |
- |
500 |
|
-- |
| 23(Internal Wiring, IS 302-1) |
- |
500 |
|
-- |
| 23(Internal Wiring, IS 302-1) |
- |
500 |
|
-- |
| 23(Internal Wiring, IS 302-1) |
- |
500 |
|
-- |
| 23(Internal Wiring, IS 302-1) |
- |
500 |
|
-- |
| 23(Internal Wiring, IS 302-1) |
- |
500 |
|
-- |
| 23(Internal Wiring, IS 302-1) |
- |
500 |
|
-- |
| 23(Internal Wiring, IS 302-1) |
- |
500 |
|
-- |
| 23(Internal Wiring, IS 302-1) |
- |
500 |
|
-- |
| 24.1(Components, IS 302-1) |
- |
750 |
|
-- |
| 24.1(Components, IS 302-1) |
- |
750 |
|
-- |
| 24.1(Components, IS 302-1) |
- |
750 |
|
-- |
| 24.1(Components, IS 302-1) |
- |
750 |
|
-- |
| 24.2(Components) |
- |
750 |
|
-- |
| 24.4(Components) |
- |
750 |
|
-- |
| 24.5(Components) |
- |
750 |
|
-- |
| 24.6(Components) |
- |
750 |
|
-- |
| 24.7(Components) |
- |
750 |
|
-- |
| 24.8(Components) |
- |
750 |
|
-- |
| 24.9(Components) |
- |
750 |
|
-- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
750 |
|
-- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
750 |
|
-- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
750 |
|
-- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
750 |
|
-- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
750 |
|
-- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
750 |
|
-- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
750 |
|
-- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
750 |
|
-- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
750 |
|
-- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
750 |
|
-- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
750 |
|
-- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
750 |
|
-- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
750 |
|
-- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
750 |
|
-- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
750 |
|
-- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
750 |
|
-- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
750 |
|
-- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
750 |
|
-- |
| 27(Provision for Earthing, IS 302-1) |
- |
500 |
|
-- |
| 27(Provision for Earthing, IS 302-1) |
- |
500 |
|
-- |
| 27(Provision for Earthing, IS 302-1) |
- |
500 |
|
-- |
| 27(Provision for Earthing, IS 302-1) |
- |
500 |
|
-- |
| 27(Provision for Earthing, IS 302-1) |
- |
500 |
|
-- |
| 28(Screws & Connections, IS 302-1) |
- |
500 |
|
-- |
| 29(Clearances and Distances through Insulation, IS 302-1) |
- |
500 |
|
-- |
| 29(Clearances and Distances through Insulation, IS 302-1) |
- |
500 |
|
-- |
| 30(Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
1500 |
|
-- |
| 30(Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
1500 |
|
-- |
| 31(Resistance of Rusting, IS 302-1) |
- |
1500 |
|
-- |
| 34.2(Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
500 |
|
-- |
| 34.2(Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
500 |
|
-- |
| 34.2(Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
500 |
|
-- |
| 34.3(Whisking egg whites ) |
- |
500 |
|
-- |
| 34.4(IDLI batter-Grinding of black gram) |
- |
1000 |
|
-- |
| 34.4(IDLI batter-Grinding of rice) |
- |
1000 |
|
-- |
| 34.4(IDLI batter-Grinding of rice) |
- |
1000 |
|
-- |
| 34.4(IDLI batter-Grinding of rice) |
- |
1000 |
|
-- |
| 34.5.1 (a)(Operational test for juicers ) |
- |
1000 |
|
-- |
| 34.5.1 (b)(Operational test for juicers ) |
- |
1000 |
|
-- |
| 34.5.2(Operational test for juicers ) |
- |
1000 |
|
-- |
| 35(Temperature withstand test for bowl) |
- |
200 |
|
-- |
| 36(Test for controls ) |
- |
500 |
|
-- |
| 37(Strength of Assembly ) |
- |
500 |
|
-- |
| 37(Strength of Assembly ) |
- |
500 |
|
-- |
| Cl 37(Strength of assembly) |
- |
500 |
|
-- |
| Cl 36(Test for controls) |
- |
1500 |
|
-- |
| Cl 35(Temperature withstand test for bowl) |
- |
600 |
|
-- |
| Cl.31(Resistance to rusting) |
- |
250 |
|
-- |
| Cl.30(Resistance to heat and fire) |
- |
250 |
|
-- |
| CL.29(Clearances, Creepage distances and Solid Insulation) |
- |
200 |
|
-- |
| Cl.28(Screws and connections) |
- |
200 |
|
-- |
| Cl.27(Provision for Earthing) |
- |
500 |
|
-- |
| Cl.26(Terminals for external conductors) |
- |
200 |
|
-- |
| Cl.25(Supply connection and external flexible cords) |
- |
100 |
|
-- |
| Cl.24(Components) |
- |
100 |
|
-- |
| Cl.23(Internal wiring) |
- |
100 |
|
-- |
| Cl.22(Construction) |
- |
200 |
|
-- |
| Cl.21(Mechanical Strength) |
- |
250 |
|
-- |
| Cl.20(Stability & Mechanical Hazards) |
- |
250 |
|
-- |
| Cl.19(Abnormal operation) |
- |
500 |
|
-- |
| Cl.18(Endurance) |
- |
2500 |
|
-- |
| Cl. 16(Leakage current and Electric strength) |
- |
750 |
|
-- |
| Cl.15(Moisture Resistance) |
- |
500 |
|
-- |
| Cl.13(Leakage current and Electric strength at operating temperature) |
- |
1000 |
|
-- |
| Cl.11(Temperature rise/ Heating) |
- |
1500 |
|
-- |
| Cl.10(Power Input and Current) |
- |
1000 |
|
-- |
| Cl.8(Protection against access to live parts/ Protection against electric shock) |
- |
500 |
|
-- |
| Cl. 7(Marking and instructions) |
- |
100 |
|
-- |
| Cl. 6(Classification) |
- |
200 |
|
-- |
| 3(GENERAL REQUIREMENTS) |
- |
50 |
|
-- |
| 4(GENERAL NOTES ON TESTS) |
- |
50 |
|
-- |
| 5(RATING) |
- |
100 |
|
-- |
| Cl 34(Operational Tests) |
- |
1500 |
|
-- |
| 14(Transient Over Voltages, IS 302-1) |
- |
500 |
|
- |
| Cl.14(Transient Over voltage) |
- |
500 |
|
- |
|
03 Oct, 2027 |
- - |
| 27 |
IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
- |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
100 |
|
-- |
| 8.1.1(Protection against live parts in all positions) |
- |
500 |
|
-- |
| 8.1.2(Protection against live parts in openings) |
- |
500 |
|
-- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
500 |
|
-- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
500 |
|
-- |
| 9(Starting of motor operation test requirements and tests) |
- |
500 |
|
-- |
| 10.1(Power input) |
- |
1000 |
|
-- |
| 10.2(Current input) |
- |
1000 |
|
-- |
| 11.1(General) |
- |
100 |
|
-- |
| 11.2(General) |
- |
800 |
|
-- |
| 11.3(Heating) |
- |
1000 |
|
-- |
| 13.1(General) |
- |
500 |
|
-- |
| 13.2(Leakage current at operating temperature) |
- |
1000 |
|
--- |
| 13.3(Electric Strength at operating temperature) |
- |
500 |
|
-- |
| 15.0(General) |
- |
500 |
|
-- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
500 |
|
-- |
| 15.2(Spillage Test) |
- |
500 |
|
-- |
| 15.3(Humidity Test) |
- |
1000 |
|
-- |
| 16.0(General) |
- |
500 |
|
-- |
| 16.1(General) |
- |
500 |
|
--- |
| 16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
--- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
500 |
|
-- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
--- |
| 18(Endurance Test requirements and tests) |
- |
2000 |
|
-- |
| 19(Abnormal Operation) |
- |
2000 |
|
-- |
| 20(Stability test) |
- |
2000 |
|
-- |
| 21(Mechanical Strength Test) |
- |
2000 |
|
-- |
| 22(Construction verification related test) |
- |
2000 |
|
-- |
| 23(General) |
- |
2000 |
|
--- |
| 24(Components) |
- |
2000 |
|
-- |
| 25(Supply connection and external flexible cords) |
- |
2000 |
|
-- |
| 26(Terminals for external conductors) |
- |
2000 |
|
-- |
| 27(Provision for earthing) |
- |
2000 |
|
-- |
| 28(Screw test and connections) |
- |
1000 |
|
-- |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
-- |
| 30.1(Ball pressure test) |
- |
500 |
|
--- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
-- |
| 30.2(Needle Flame Test) |
- |
500 |
|
-- |
| 31(Resistance to Rusting) |
- |
1000 |
|
-- |
| 4(General requirement) |
- |
50 |
|
-- |
| 16(Leakage current and electric strength) |
- |
500 |
|
-- |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
-- |
| 18(Endurance) |
- |
2000 |
|
-- |
| 8.1.5(Live parts of built-in appliances) |
- |
500 |
|
-- |
| 11.4(Heating appliances) |
- |
1000 |
|
-- |
| 11.5(Motor-operated appliances) |
- |
1000 |
|
-- |
| 11.6(Combined appliances) |
- |
1000 |
|
-- |
| 11.7(Duration corresponding) |
- |
1000 |
|
-- |
| 11.8(Temperature rise) |
- |
1000 |
|
-- |
| 4(General Requirement) |
- |
50 |
|
- |
| 5(General conditions for tests) |
- |
50 |
|
-- |
| 6(Classification- IS 302-1) |
- |
250 |
|
-- |
| 14(Transient Over Voltages) |
- |
1000 |
|
- |
|
03 Oct, 2027 |
- 19.11.4.1 to 19.11.4.7
32 (Radiation Toxicity and Similar Hazards) |
| 28 |
IS 302 : Part 2 : Sec 21 (2018) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 21 stationary storage type electric water heaters (Second Revision) |
- |
13600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 31.0(Resistance To Rusting) |
- |
500 |
|
-- |
| 30.0(Resistance To Heat and Fire) |
- |
1000 |
|
-- |
| 29.0(Creepage Distances and Clearances) |
- |
500 |
|
-- |
| 28.0(Screws and Connections) |
- |
500 |
|
-- |
| 27.0(Provision For Earthing) |
- |
500 |
|
-- |
| 26.0(Terminals for external conductors) |
- |
500 |
|
-- |
| 25.0(Supply Connection and External Flexible Cords) |
- |
500 |
|
-- |
| 23.0(Internal Wiring) |
- |
300 |
|
-- |
| 22.0(Construction) |
- |
200 |
|
-- |
| 21.0(Mechanical Strength) |
- |
200 |
|
-- |
| 20.0(Stability and mechanical hazards) |
- |
300 |
|
-- |
| 19.0(Abnormal Operation) |
- |
500 |
|
-- |
| 17.0(Overload Protection of transformer and associated circuit) |
- |
500 |
|
-- |
| 16.0(Leakage current and Electric strength (After Humidity (Environmental) Treatment)) |
- |
500 |
|
-- |
| 15.0(Moisture resistance) |
- |
1500 |
|
-- |
| 13.0(Leakage Current and electric strength at operating temperature) |
- |
1500 |
|
-- |
| 11.0(Heating) |
- |
1000 |
|
-- |
| 10.0(Input and Current) |
- |
1000 |
|
-- |
| 8.0(Protection against access to live parts) |
- |
500 |
|
-- |
| 6.0(Classification) |
- |
100 |
|
-- |
| 7.0(Marking and Instructions) |
- |
500 |
|
-- |
| 24(Components) |
- |
500 |
|
-- |
| 4(GENERAL REQUIREMENTS) |
- |
0 |
|
Visual inspection |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
Visual Inspection |
| 14.0(Transient Overvoltage) |
- |
1000 |
|
- |
|
03 Oct, 2027 |
- Cl 19.11.4.1 to Cl 19.11.4.7
32 (RADIATION TOXICITY AND SIMILAR HAZARDS) |
| 29 |
IS 302 : Part 2 : Sec 9 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 9 toasters, grills, roasters and similar appliances (First Revision) |
----- |
9000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.31(Verification) |
- |
50 |
|
- |
| Cl.30(Verification) |
- |
50 |
|
- |
| CL.29(Verification) |
- |
50 |
|
- |
| Cl.28(Verification) |
- |
50 |
|
- |
| Cl.27(Verification) |
- |
50 |
|
- |
| Cl.26(Verification) |
- |
50 |
|
- |
| Cl.25(Verification) |
- |
50 |
|
- |
| Cl.24(Verification) |
- |
50 |
|
- |
| Cl.23(Verification) |
- |
50 |
|
- |
| Cl.22(Verification) |
- |
50 |
|
- |
| Cl.21(Verification) |
- |
50 |
|
- |
| Cl.20(Verification) |
- |
50 |
|
- |
| Cl.19(Verification) |
- |
50 |
|
- |
| Cl. 16(Verification) |
- |
50 |
|
- |
| Cl.15.1(Moisture Resistance) |
- |
50 |
|
- |
| Cl.14(Verification) |
- |
50 |
|
- |
| Cl.13(Verification) |
- |
50 |
|
- |
| Cl.11(Verification) |
- |
50 |
|
- |
| Cl.10(Verification) |
- |
50 |
|
- |
| Cl.8(Verification) |
- |
50 |
|
- |
| Cl. 7(Verification) |
- |
50 |
|
- |
| Cl. 6(Classification- IS 302-1) |
- |
50 |
|
- |
| Cl. 31
IS 302-2-9(Resistance To Rusting ) |
- |
500 |
|
- |
| Cl. 30
IS 302-2-9(Resistance To Heat, Fire And Tracking) |
- |
500 |
|
- |
| Cl. 29
IS 302-2-9(Creepage Distances, Clearances And Distances Through Insulation) |
- |
500 |
|
- |
| Cl. 28
IS 302-2-9(Screws and Connections) |
- |
100 |
|
- |
| Cl. 27
IS 302-2-9(Provision For Earthing ) |
- |
500 |
|
- |
| Cl. 26
IS 302-2-9(Terminal For External Conductors ) |
- |
100 |
|
- |
| Cl. 25
IS 302-2-9(Supply Connections and External Flexible Cables and Cords ) |
- |
500 |
|
- |
| Cl. 24
IS 302-2-9(Components) |
- |
200 |
|
- |
| Cl. 23
IS 302-2-9(Internal Wiring) |
- |
200 |
|
- |
| Cl. 22
IS 302-2-9(Construction ) |
- |
200 |
|
- |
| Cl. 21
IS 302-2-9(Mechanical Strength) |
- |
200 |
|
- |
| Cl. 20
IS 302-2-9(Stability and mechanical Hazards) |
- |
200 |
|
- |
| Cl. 19
IS 302-2-9(Abnormal Operation ) |
- |
500 |
|
- |
| Cl. 18
IS 302-2-9(Endurance) |
- |
200 |
|
- |
| Cl. 17
IS 302-2-9(Overload protection of transformers and associated circuits.) |
- |
200 |
|
- |
| Cl. 16
IS 302-2-9(Leakage Current and Electric strength ) |
- |
500 |
|
- |
| Cl. 15
IS 302-2-9(Moisture Resistance) |
- |
500 |
|
- |
| Cl. 14
IS 302-2-9(Transient overvoltage) |
- |
500 |
|
- |
| Cl. 13.3 IS 302-2-9(Leakage Current & Electric Strength at Operating Temperature) |
- |
500 |
|
- |
| Cl. 11
IS 302-2-9(Heating) |
- |
500 |
|
- |
| Cl. 10
IS 302-2-9(Power Input and Current ) |
- |
1000 |
|
- |
| Cl. 9
IS 302-2-9(Starting of motor operated appliances) |
- |
250 |
|
- |
| Cl. 8
IS 302-2-9(Protection against access to live parts) |
- |
500 |
|
- |
| Cl. 7
IS 302-2-9(Marking and Instruction) |
- |
200 |
|
- |
| Cl. 6 IS 302-2-9(Classification- IS 302-1) |
- |
200 |
|
- |
| 31(Resistance to rusting) |
- |
50 |
|
- |
| 31(Resistance to rusting) |
- |
50 |
|
- |
| 30.2.4(Resistance to heat and fire) |
- |
50 |
|
- |
| 30.2(Resistance to heat and fire) |
- |
50 |
|
- |
| 30.1(Resistance to heat and fire) |
- |
50 |
|
- |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
50 |
|
- |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
50 |
|
- |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
50 |
|
- |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
50 |
|
- |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
50 |
|
- |
| 28.2 to 28.4(Screws and connections) |
- |
50 |
|
- |
| 28.1, Table No.-14(Screws and connections) |
- |
50 |
|
- |
| 27.6(Provision for earthing) |
- |
50 |
|
- |
| 27.5(Provision for earthing) |
- |
50 |
|
- |
| 27.1 to 27.4(Provision for earthing) |
- |
50 |
|
- |
| 26.10 & 26.11(Terminals for external conductors) |
- |
50 |
|
- |
| 26.9(Terminals for external conductors) |
- |
50 |
|
- |
| 26.1 to 26.8(Terminals for external conductors) |
- |
50 |
|
- |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 25.15(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 25.14(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 25.14(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 25.4(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 25.3(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 25.2(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 25.1(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 24.101(Components) |
- |
50 |
|
- |
| 24.101(Components) |
- |
50 |
|
- |
| 24.2 to 24.6(Components) |
- |
50 |
|
- |
| 24.1(Components) |
- |
50 |
|
- |
| 23.6 to 23.10(Internal wiring) |
- |
50 |
|
- |
| 23.5(Internal wiring) |
- |
50 |
|
- |
| 23.4(Internal wiring) |
- |
50 |
|
- |
| 23.3(Internal wiring) |
- |
50 |
|
- |
| 23.1 & 23.2(Internal wiring) |
- |
50 |
|
- |
| 22.111(Constructions) |
- |
50 |
|
- |
| 22.111(Constructions) |
- |
50 |
|
- |
| 22.11o(Constructions) |
- |
50 |
|
- |
| 22.109(Constructions) |
- |
50 |
|
- |
| 22.108(Constructions) |
- |
50 |
|
- |
| 22.101 to 22.107(Constructions) |
- |
50 |
|
- |
| 22.13 to 22.48(Constructions) |
- |
50 |
|
- |
| 22.12(Constructions) |
- |
50 |
|
- |
| 22.11(Constructions) |
- |
50 |
|
- |
| 22.11(Constructions) |
- |
50 |
|
- |
| 22.7 to 22.10(Constructions) |
- |
50 |
|
- |
| 22.6(Constructions) |
- |
50 |
|
- |
| 22.5(Constructions) |
- |
50 |
|
- |
| 22.4(Constructions) |
- |
50 |
|
- |
| 22.3(Constructions) |
- |
50 |
|
- |
| 22.2(Constructions) |
- |
50 |
|
- |
| 22.1(Constructions) |
- |
50 |
|
- |
| 21.101(MECHANICAL STRENGTH) |
- |
50 |
|
- |
| 21.101(MECHANICAL STRENGTH) |
- |
50 |
|
- |
| 21.2(MECHANICAL STRENGTH) |
- |
50 |
|
- |
| 21.1(MECHANICAL STRENGTH) |
- |
50 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
50 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
50 |
|
- |
| 19.104(ABNORMAL OPERATION) |
- |
50 |
|
- |
| 19.103(ABNORMAL OPERATION) |
- |
50 |
|
- |
| 19.102(ABNORMAL OPERATION) |
- |
50 |
|
- |
| 19.101(ABNORMAL OPERATION) |
- |
50 |
|
- |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
50 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
50 |
|
- |
| 16.3(Insulation resistance test) |
- |
50 |
|
- |
| 16.3(Electric strength test) |
- |
50 |
|
- |
| 16.1 & 16.2(Leakage current test) |
- |
50 |
|
- |
| 15.3(Moisture resistance) |
- |
50 |
|
- |
| 15.3(Moisture resistance) |
- |
50 |
|
- |
| 15.3(Moisture resistance) |
- |
50 |
|
- |
| 15.2(Moisture resistance) |
- |
50 |
|
- |
| 15.2(Moisture resistance) |
- |
50 |
|
- |
| 15.2(Moisture resistance) |
- |
50 |
|
- |
| 15.2(Moisture resistance) |
- |
50 |
|
- |
| 15.1(Moisture resistance) |
- |
50 |
|
- |
| 14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
50 |
|
- |
| 13.3 and Table No.- 4(Electric strength test) |
- |
50 |
|
- |
| 13.1, 13.2(Leakage current test) |
- |
50 |
|
- |
| 13.1, 13.2(Leakage current test) |
- |
50 |
|
- |
| 11.101(Heating) |
- |
50 |
|
- |
| 11.1 to 11.8, Table No.-3(Heating) |
- |
50 |
|
- |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
50 |
|
- |
| 8.1.5(Protection against access to live parts) |
- |
50 |
|
- |
| 8.1.4(Protection against access to live parts) |
- |
50 |
|
- |
| 8.1.3(Protection against access to live parts) |
- |
50 |
|
- |
| 8.1.2(Protection against access to live parts) |
- |
50 |
|
- |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
50 |
|
- |
| 7.14(Legibility & Durability of Markings test) |
- |
50 |
|
- |
| 7.1 to 7.13, 7.15, 7.16(Marking) |
- |
50 |
|
- |
| 31(Resistance to rusting) |
- |
50 |
|
- |
| 31(Resistance to rusting) |
- |
50 |
|
- |
| 30.2.4(Resistance to heat and fire) |
- |
50 |
|
- |
| 30.2(Resistance to heat and fire) |
- |
50 |
|
- |
| 30.1(Resistance to heat and fire) |
- |
50 |
|
- |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
50 |
|
- |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
50 |
|
- |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
50 |
|
- |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
50 |
|
- |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
50 |
|
- |
| 28.2 to 28.4(Screws and connections) |
- |
50 |
|
- |
| 28.1, Table No.-14(Screws and connections) |
- |
50 |
|
- |
| 27.6(Provision for earthing) |
- |
50 |
|
- |
| 27.5(Provision for earthing) |
- |
50 |
|
- |
| 27.1 to 27.4(Provision for earthing) |
- |
50 |
|
- |
| 26.10 & 26.11(Terminals for external conductors) |
- |
50 |
|
- |
| 26.9(Terminals for external conductors) |
- |
50 |
|
- |
| 26.1 to 26.8(Terminals for external conductors) |
- |
50 |
|
- |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 25.15(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 25.14(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 25.4(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 25.3(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 25.2(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 25.1(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 24.101(Components) |
- |
50 |
|
- |
| 24.101(Components) |
- |
50 |
|
- |
| 24.2 to 24.6(Components) |
- |
50 |
|
- |
| 24.1(Components) |
- |
50 |
|
- |
| 23.6 to 23.10(Internal wiring) |
- |
50 |
|
- |
| 23.5(Internal wiring) |
- |
50 |
|
- |
| 23.4(Internal wiring) |
- |
50 |
|
- |
| 23.3(Internal wiring) |
- |
50 |
|
- |
| 23.1 & 23.2(Internal wiring) |
- |
50 |
|
- |
| 22.111(Constructions) |
- |
50 |
|
- |
| 22.111(Constructions) |
- |
50 |
|
- |
| 22.11o(Constructions) |
- |
50 |
|
- |
| 22.109(Constructions) |
- |
50 |
|
- |
| 22.108(Constructions) |
- |
50 |
|
- |
| 22.101 to 22.107(Constructions) |
- |
50 |
|
- |
| 22.13 to 22.48(Constructions) |
- |
50 |
|
- |
| 22.12(Constructions) |
- |
50 |
|
- |
| 22.11(Constructions) |
- |
50 |
|
- |
| 22.11(Constructions) |
- |
50 |
|
- |
| 22.7 to 22.10(Constructions) |
- |
50 |
|
- |
| 22.6(Constructions) |
- |
50 |
|
- |
| 22.5(Constructions) |
- |
50 |
|
- |
| 22.4(Constructions) |
- |
50 |
|
- |
| 22.3(Constructions) |
- |
50 |
|
- |
| 22.2(Constructions) |
- |
50 |
|
- |
| 21.101(MECHANICAL STRENGTH) |
- |
50 |
|
- |
| 21.101(MECHANICAL STRENGTH) |
- |
50 |
|
- |
| 21.2(MECHANICAL STRENGTH) |
- |
50 |
|
- |
| 21.1(MECHANICAL STRENGTH) |
- |
50 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
50 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
50 |
|
- |
| 19.104(ABNORMAL OPERATION) |
- |
50 |
|
- |
| 19.103(ABNORMAL OPERATION) |
- |
50 |
|
- |
| 19.102(ABNORMAL OPERATION) |
- |
50 |
|
- |
| 19.101(ABNORMAL OPERATION) |
- |
50 |
|
- |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
50 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
50 |
|
- |
| 16.3(Insulation resistance test) |
- |
50 |
|
- |
| 16.1 & 16.2(Leakage current test) |
- |
50 |
|
- |
| 15.3(Moisture resistance) |
- |
50 |
|
- |
| 15.3(Moisture resistance) |
- |
50 |
|
- |
| 15.3(Moisture resistance) |
- |
50 |
|
- |
| 15.2(Moisture resistance) |
- |
50 |
|
- |
| 15.2(Moisture resistance) |
- |
50 |
|
- |
| 15.2(Moisture resistance) |
- |
50 |
|
- |
| 15.2(Moisture resistance) |
- |
50 |
|
- |
| 15.1(Moisture resistance) |
- |
50 |
|
- |
| 14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
50 |
|
- |
| 13.3 and Table No.- 4(Electric strength test) |
- |
50 |
|
- |
| 13.1, 13.2(Leakage current test) |
- |
50 |
|
- |
| 13.1, 13.2(Leakage current test) |
- |
50 |
|
- |
| 11.101(Heating) |
- |
50 |
|
- |
| 11.1 to 11.8, Table No.-3(Heating) |
- |
50 |
|
- |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
50 |
|
- |
| 8.1.5(Protection against access to live parts) |
- |
50 |
|
- |
| 8.1.4(Protection against access to live parts) |
- |
50 |
|
- |
| 8.1.3(Protection against access to live parts) |
- |
50 |
|
- |
| 8.1.2(Protection against access to live parts) |
- |
50 |
|
- |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
50 |
|
- |
| 7.14(Legibility & Durability of Markings test) |
- |
50 |
|
- |
| 7.1 to 7.13, 7.15, 7.16(Marking) |
- |
50 |
|
- |
| 31(Resistance to Rusting) |
- |
50 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
50 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
50 |
|
- |
| 28(Screws & Connections) |
- |
50 |
|
- |
| 27(Provision For Earthing) |
- |
50 |
|
- |
| 26(Terminals For External Conductors) |
- |
50 |
|
- |
| 25(Supply Connection & External Flexible Cords) |
- |
50 |
|
- |
| 24(Components) |
- |
50 |
|
- |
| 23(Internal wiring) |
- |
50 |
|
- |
| 22(Construction) |
- |
50 |
|
- |
| 21(Mechanical strength) |
- |
50 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 19(Abnormal Operation) |
- |
50 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
50 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
50 |
|
- |
| 15(Moisture Resistance) |
- |
50 |
|
- |
| 14(Transient Over Voltage) |
- |
50 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
50 |
|
- |
| 11(Temperature Rise/ Heating) |
- |
50 |
|
- |
| 10(Power Input
& Current) |
- |
50 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
50 |
|
- |
| 8(Protection against access to live parts) |
- |
50 |
|
- |
| 31(Resistance to Rusting) |
- |
50 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
50 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
50 |
|
- |
| 28(Screws & Connections) |
- |
50 |
|
- |
| 27(Provision For Earthing) |
- |
50 |
|
- |
| 26(Terminals For External Conductors) |
- |
50 |
|
- |
| 25(Supply Connection & External Flexible Cords) |
- |
50 |
|
- |
| 24(Components) |
- |
50 |
|
- |
| 23(Internal wiring) |
- |
50 |
|
- |
| 22(Construction) |
- |
50 |
|
- |
| 21(Mechanical strength) |
- |
50 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 19(Abnormal Operation) |
- |
50 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
50 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
50 |
|
- |
| 15(Moisture Resistance) |
- |
50 |
|
- |
| 14(Transient Over Voltage) |
- |
50 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
50 |
|
- |
| 11(Temperature Rise/ Heating) |
- |
50 |
|
- |
| 10(Power Input
& Current) |
- |
50 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
50 |
|
- |
| 8(Protection against access to live parts) |
- |
50 |
|
- |
| 25.14(Supply connection and external flexible cords) |
- |
50 |
|
- |
| 22.1(Constructions) |
- |
50 |
|
- |
| 16.3(Electric strength test) |
- |
50 |
|
- |
|
03 Oct, 2027 |
- Included.w.e.f.07.11.2024 Exclusion 32 (RADIATION, TOXICITY AND SIMILAR HAZARDS) 19.11.4.1 to 19.11.4.5 (EMI/EMC) |
| 30 |
IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
----- |
14500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
200 |
|
- |
| 7.0(Marking and instructions) |
- |
500 |
|
- |
| 8.0(Protection against access to live part test) |
- |
500 |
|
- |
| 10.0(Power Input and current test) |
- |
1500 |
|
- |
| 11.0(Heating test) |
- |
1000 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
1000 |
|
- |
| 14.0(Transient voltages) |
- |
500 |
|
- |
| 15.0(Moisture Resistance) |
- |
700 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
700 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
100 |
|
- |
| 18.0(Endurance test) |
- |
100 |
|
- |
| 19.0(Abnormal Operations) |
- |
1000 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
500 |
|
- |
| 21.0(Mechanical Strength) |
- |
500 |
|
- |
| 22.0(Construction verification related tests) |
- |
500 |
|
- |
| 23.0(Internal wiring) |
- |
500 |
|
- |
| 24.0(Components) |
- |
500 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
1000 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
150 |
|
- |
| 27.0(Provision for Earthing) |
- |
1000 |
|
- |
| 28.0(Screws and connections) |
- |
400 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
500 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
500 |
|
- |
| 31.0(Resistance to rusting) |
- |
500 |
|
- |
| 4(General Requirements) |
- |
50 |
|
- |
| 5(General condition for the tests) |
- |
50 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
50 |
|
- |
| 6.0(Classification) |
- |
200 |
|
- |
| 7.0(Marking and instructions) |
- |
500 |
|
- |
| 8.0(Protection against access to live part test) |
- |
500 |
|
- |
| 10.0(Power Input and current test) |
- |
1500 |
|
- |
| 11.0(Heating test) |
- |
1000 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
1000 |
|
- |
| 14.0(Transient voltages) |
- |
500 |
|
- |
| 15.0(Moisture Resistance) |
- |
700 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
700 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
100 |
|
- |
| 18.0(Endurance test) |
- |
100 |
|
- |
| 19.0(Abnormal Operations) |
- |
1000 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
500 |
|
- |
| 21.0(Mechanical Strength) |
- |
500 |
|
- |
| 22.0(Construction verification related tests) |
- |
500 |
|
- |
| 23.0(Internal wiring) |
- |
500 |
|
- |
| 24.0(Components) |
- |
500 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
1000 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
150 |
|
- |
| 27.0(Provision for Earthing) |
- |
1000 |
|
- |
| 28.0(Screws and connections) |
- |
400 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
500 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
500 |
|
- |
| 31.0(Resistance to rusting) |
- |
500 |
|
- |
| 4(General Requirements) |
- |
50 |
|
- |
| 5(General condition for the tests) |
- |
50 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
50 |
|
- |
| 6.0(Classification) |
- |
200 |
|
- |
| 7.0(Marking and instructions) |
- |
0 |
|
- |
| 8.0(Protection against access to live part test) |
- |
500 |
|
- |
| 10.0(Power Input and current test) |
- |
1500 |
|
- |
| 11.0(Heating test) |
- |
1000 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
1000 |
|
- |
| 14.0(Transient voltages) |
- |
500 |
|
- |
| 15.0(Moisture Resistance) |
- |
700 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
700 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
100 |
|
- |
| 18.0(Endurance test) |
- |
100 |
|
- |
| 19.0(Abnormal Operations) |
- |
1000 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
500 |
|
- |
| 21.0(Mechanical Strength) |
- |
500 |
|
- |
| 22.0(Construction verification related tests) |
- |
500 |
|
- |
| 23.0(Internal wiring) |
- |
500 |
|
- |
| 24.0(Components) |
- |
500 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
1000 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
150 |
|
- |
| 27.0(Provision for Earthing) |
- |
1000 |
|
- |
| 28.0(Screws and connections) |
- |
400 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
500 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
500 |
|
- |
| 31.0(Resistance to rusting) |
- |
500 |
|
- |
| 4(General Requirements) |
- |
50 |
|
- |
| 5(General condition for the tests) |
- |
50 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
50 |
|
- |
| 6.0(Classification) |
- |
200 |
|
- |
| 7.0(Marking and instructions) |
- |
500 |
|
- |
| 8.0(Protection against access to live part test) |
- |
500 |
|
- |
| 10.0(Power Input and current test) |
- |
1500 |
|
- |
| 11.0(Heating test) |
- |
1000 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
1000 |
|
- |
| 14.0(Transient voltages) |
- |
500 |
|
- |
| 15.0(Moisture Resistance) |
- |
700 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
700 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
100 |
|
- |
| 18.0(Endurance test) |
- |
100 |
|
- |
| 19.0(Abnormal Operations) |
- |
1000 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
500 |
|
- |
| 21.0(Mechanical Strength) |
- |
500 |
|
- |
| 22.0(Construction verification related tests) |
- |
500 |
|
- |
| 23.0(Internal wiring) |
- |
500 |
|
- |
| 24.0(Components) |
- |
500 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
1000 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
150 |
|
- |
| 27.0(Provision for Earthing) |
- |
1000 |
|
- |
| 28.0(Screws and connections) |
- |
400 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
500 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
500 |
|
- |
| 31.0(Resistance to rusting) |
- |
500 |
|
- |
| 4(General Requirements) |
- |
50 |
|
- |
| 5(General condition for the tests) |
- |
50 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
50 |
|
- |
| 6.0(Classification) |
- |
200 |
|
- |
| 7.0(Marking and instructions) |
- |
500 |
|
- |
| 8.0(Protection against access to live part test) |
- |
500 |
|
- |
| 10.0(Power Input and current test) |
- |
1500 |
|
- |
| 11.0(Heating test) |
- |
1000 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
1000 |
|
- |
| 14.0(Transient voltages) |
- |
500 |
|
- |
| 15.0(Moisture Resistance) |
- |
700 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
700 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
100 |
|
- |
| 18.0(Endurance test) |
- |
100 |
|
- |
| 19.0(Abnormal Operations) |
- |
1000 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
500 |
|
- |
| 21.0(Mechanical Strength) |
- |
500 |
|
- |
| 22.0(Construction verification related tests) |
- |
500 |
|
- |
| 23.0(Internal wiring) |
- |
500 |
|
- |
| 24.0(Components) |
- |
500 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
1000 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
150 |
|
- |
| 27.0(Provision for Earthing) |
- |
1000 |
|
- |
| 28.0(Screws and connections) |
- |
400 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
500 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
500 |
|
- |
| 31.0(Resistance to rusting) |
- |
500 |
|
- |
| 4(General Requirements) |
- |
50 |
|
- |
| 5(General condition for the tests) |
- |
50 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
50 |
|
- |
|
03 Oct, 2027 |
- Included.w.e.f.05.11.2024
Exclusion
32 (RADIATION, TOXICITY AND SIMILAR HAZARDS)
19.11.4.1 to 19.11.4.5 (EMI/EMC) |