31 |
IS 456 (2000) |
Plain and reinforced concrete - Code of practice (Fourth Revision) |
- |
4000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.4-Table-1 (v)-IS: 3025(P-17)(Suspended matter) |
- |
750 |
|
- |
5.4-Table-1 (iv)-IS: 3025(P-32)(Chloride) |
- |
1000 |
|
- |
5.4-Table-1 (ii)-IS: 3025(P-24)(Sulphate) |
- |
750 |
|
- |
5.4-Table-1 (i)-IS: 3025(P-18)(In-Organic) |
- |
750 |
|
- |
5.4-Table-1 (i)-IS: 3025(P-18)(Organic ) |
- |
750 |
|
- |
5.4.2-IS: 3025(P-11)(Ph) |
- |
750 |
|
- |
5.4-(b)-IS: 3025 (P-23)(Volume of 0.02 N H2SO4 to neutralized 100 ml of water using mixed indicator) |
- |
750 |
|
- |
5.4-(a)-IS: 3025 (P-22)(Volume of 0.02 N NaOH to neutralized 100 ml of water using phenolphthalein indicator) |
- |
750 |
|
- |
16.1(Average Compressive Strength) |
- |
1500 |
|
- |
|
18 Dec, 2027 |
- - |
32 |
IS 12592 (2002) |
Precast concrete manhole cover and frame - Specification (First Revision) |
All |
14821 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9.1(General) |
- |
3000 |
|
General |
3(Type/Shape of Cover) |
- |
3000 |
|
General |
8(LIFTING HOOKS) |
- |
7500 |
|
Dimension |
5.2 and Table 1(Dimensions of Frame - A) |
- |
7500 |
|
Dimension |
5.2 and Table 1(Dimensions of Frame - B) |
- |
7500 |
|
Dimension |
5.2 and Table 1(Dimensions of Frame - C) |
- |
7500 |
|
Dimension |
5.2 and Table 1(Dimensions of Frame - D) |
- |
7500 |
|
Dimension |
5.2 and Table 1(Dimensions of Frame - E) |
- |
7500 |
|
Dimension |
5.2 and Table 1(Dimensions of Frame - F) |
- |
7500 |
|
Dimension |
5.2(Dimensions of cover- Diameter) |
- |
7500 |
|
Dimension |
5.2(Clearance at top between the frame and the cover all round the periphery) |
- |
7500 |
|
Dimension |
5.2(Top surface ofthe frame and cover is in level) |
- |
7500 |
|
Dimension |
5.2(Suitable taper matching with taper given for the frame shall be provided to the periphery of the cover) |
- |
7500 |
|
Dimension |
5.2 and Fig 1(Clear cover to reinforcement) |
- |
7500 |
|
Dimension |
5.2 and Fig 1(Distance of housing from the edge) |
- |
7500 |
|
Dimension |
7.4.1(Edge Protection and Finishing - Frame) |
- |
7500 |
|
Dimension |
7.4.2(Edge Protection and Finishing - Cover) |
- |
7500 |
|
Dimension |
9.3 and Table and
Annex C(Load Test) |
- |
10000 |
|
Load Test |
Clause No. 6(Design) |
- |
7500 |
|
Dimension |
Clause No. 7.4.1(Edge protection and finishing of frame (Size of mild steel flat)) |
- |
7500 |
|
Dimension |
Clause No. 7.4.1(Edge protection and finishing of frame (Steel connectors)) |
- |
7500 |
|
Dimension |
Clause No. 7.4.2(Edge protection and finishing of cover (Cover finish of top surface)) |
- |
7500 |
|
Dimension |
Clause No. 7.4.2(Edge protection and finishing of cover (Thikness of MS sheet)) |
- |
7500 |
|
Dimension |
Clause No. 7.4.4(Compatitbilty of Seating of cover and frame) |
- |
7500 |
|
Dimension |
Clause No. 8(Lifting Hooks (Diameter of MS rod)) |
- |
7500 |
|
Dimension |
Clause No. 8(Lifting Device) |
- |
7500 |
|
Dimension |
Clause No. 9.3, 12.3 & C-1.1, Table No. 2(Test Load) |
- |
10000 |
|
Load Test |
Clause No. 9.3, 12.3 & C-1.1, Table No. 2(2/3rd of Test Load) |
- |
10000 |
|
Load Test |
Clause No. 9.3 Annex C(Permanent set of cover) |
- |
10000 |
|
Load Test |
Clause No. 9.3 Annex C(Cracks at bottom side of the cover ) |
- |
10000 |
|
Load Test |
Clause No. 9.3 Annex C(Adhesion between concrete and reinforcing steel) |
- |
10000 |
|
Load Test |
Clause No. 5.2, Figure 1(Typical Illustration of circular precast concrete manhole cover) |
- |
7500 |
|
Dimension |
|
18 Dec, 2027 |
- - |
33 |
IS 12894 (2002) |
Pulverized fuel ash - Lime bricks - Specification |
All |
6500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(General Requirements) |
- |
500 |
|
General Requirements |
3.2(General Requirements) |
- |
500 |
|
General Requirements |
3.3(General Requirements) |
- |
500 |
|
General Requirements |
3.4(General Requirements) |
- |
500 |
|
General Requirements |
3.5(General Requirements) |
- |
500 |
|
General Requirements |
5.1(Dimensions) |
- |
1000 |
|
All Dimensions |
7.1, Table -1(Average Wet Compressive Strength) |
- |
2000 |
|
All Dimensions |
7.2(Drying Shrinkage) |
- |
5000 |
|
Drying Shrinkage |
7.3(Efflorescence Test) |
- |
1000 |
|
Efflorescence Test |
7.4(Water Absorption) |
- |
2000 |
|
Water Absorption |
|
18 Dec, 2027 |
- - |
34 |
IS 2645 (2003) |
Integral waterproofing compounds for cement mortar and concrete - Specification (Second Revision) |
- |
13875 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 3.1(The permeability of water in specimen Prepared with WPC shall be less than half the permeability of plain cement specimens. (i.e ; < 50 percent)) |
- |
5000 |
|
Permeability |
Cl 3.2(Initial & Final) |
- |
1000 |
|
Initial & Final Setting |
Cl 3.3(Compressive Strength, At 3days & 7 days) |
- |
3000 |
|
Compressive strength |
Cl 3.1(The permeability of water in specimen Prepared with WPC shall be less than half the permeability of plain cement specimens. (i.e ; < 50 percent)) |
- |
5000 |
|
Permeability to water |
Cl 3.2(Initial & Final) |
- |
1000 |
|
Initial & Final Setting |
Cl 3.3(Compressive Strength, At 3days & 7 days) |
- |
3000 |
|
Compressive strength |
Cl 3.1(The permeability of water in specimen Prepared with WPC shall be less than half the permeability of plain cement specimens. (i.e ; < 50 percent)) |
- |
5000 |
|
Permeability to water |
Cl 3.2(Initial & Final) |
- |
1000 |
|
Initial & Final Setting |
Cl 3.3(Compressive Strength, At 3days & 7 days) |
- |
3000 |
|
Compressive strength |
Clause 3.4(Chloride content) |
- |
1000 |
|
Chloride content |
Clause 3.3(Compressive strength of cement mortar with waterproofing compound at 3 days (72 ± 1 h)) |
- |
3000 |
|
Testing Charges As per Parameter |
Clause 3.3(Compressive strength of cement mortar at 3 days (72 ± 1 h)) |
- |
3000 |
|
Testing Charges As per Parameter |
Clause 3.2(Final setting time of cement) |
- |
3000 |
|
Testing Charges As per Parameter |
Clause 3.1
(Permeability to water of cement mortar) |
- |
5000 |
|
Testing Charges As per Parameter |
Clause 3.1
(Permeability to water of cement mortar with Water proofing compound) |
- |
5000 |
|
Testing Charges As per Parameter |
Clause 3.2(Initial setting time of cement) |
- |
3000 |
|
Testing Charges As per Parameter |
Clause 3.2(Initial setting time of cement with Water proofing compound) |
- |
3000 |
|
Testing Charges As per Parameter |
Clause 3.2(Final setting time of cement with Water proofing compound) |
- |
3000 |
|
Testing Charges As per Parameter |
Clause 3.3(Compressive strength of cement mortar at 7 days (168 ± 2 h)) |
- |
3000 |
|
Testing Charges As per Parameter |
Clause 3.3(Compressive strength of cement mortar with waterproofing compound at 7 days (168 ± 2 h)) |
- |
3000 |
|
Testing Charges As per Parameter |
|
18 Dec, 2027 |
- - |
35 |
IS 10748 (2004) |
Hot - Rolled steel strip for welded tubes and pipes - Specification (Second Revision) |
All |
11000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 8 & Table 3(UTM) |
- |
3000 |
|
Tensile |
Cl 9(Press) |
- |
1500 |
|
Bend |
Cl 11(Workmanship) |
- |
500 |
|
Freedom From Defects |
Cl 12 & 13(Length, Width & Thickness) |
- |
500 |
|
Dimension |
7.1(Carbon %) |
- |
500 |
|
Carbon |
7.1(Manganese %) |
- |
500 |
|
Manganese |
7.1(Phosphorus %) |
- |
500 |
|
Phosphorous |
7.1(Sulphur %) |
- |
500 |
|
Sulphur |
7.1(Silicon %) |
- |
500 |
|
Silicon |
7.1( Copper %) |
- |
100 |
|
Copper |
7.1( Aluminium %) |
- |
100 |
|
Aluminium |
7.1( Nb) |
- |
100 |
|
Niobium |
7.1(V) |
- |
100 |
|
Vanadium |
7.1( Ti) |
- |
100 |
|
Titanium |
7.1(Cr) |
- |
100 |
|
Chromium |
7.1(Mo) |
- |
100 |
|
Molybdenum |
7.1(Ni) |
- |
100 |
|
Nickle |
7.1(CE) |
- |
300 |
|
Carbon Equivalent |
7.1( Nitrogen%) |
- |
1500 |
|
Nitrogen |
Cl. 8, Table 3(Yield Stress) |
- |
3000 |
|
Yield Stress |
Cl. 8, Table 3(Elongation) |
- |
3000 |
|
Elongation |
Cl. 14(Weight) |
- |
500 |
|
Weight |
Cl. 12, 13(Camber) |
- |
500 |
|
Dimension |
|
18 Dec, 2027 |
- - |
36 |
IS 2185 : Part 1 (2005) |
Concrete masonry units - Specification: Part 1 hollow and solid concrete blocks (Third Revision) |
All |
20000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9.1(PHYSICAL REQUIREMENTS-General) |
- |
1000 |
|
General and Visual Inspection |
9.2 & 4.2(PHYSICAL REQUIREMENTS-Nominal Dimensions 1.Length 2.Hight 3. Width) |
- |
1000 |
|
All Dimensions |
9.2 & 4.2.3(Nominal Dimensions-variation in the length of units ) |
- |
1000 |
|
All Dimensions |
9.2 & 4.2.3(Nominal Dimensions -variation in height and width of units ) |
- |
1000 |
|
All Dimensions |
9.2 & 4.2.4, Table-1(Nominal Dimensions-thickness of
the face shell) |
- |
1000 |
|
All Dimensions |
9.2 & 4.2.4, Table-1(Nominal Dimensions-thickness of
the Web shell) |
- |
1000 |
|
All Dimensions |
9.3 & 5.1 & 5.2 Table 2(PHYSICAL REQUIREMENTS-Blocks Density - 1.Hollow (Open and Closed Cavity) Concrete Block- Grade Aor Grade B 2.Solid Concrete Block — Grade C) |
- |
1000 |
|
Blocks Density |
9.4- Table 2(PHYSICAL REQUIREMENTS - Compressive Strength 1.Minimum Average Compressive Strength of Units 2.Minimum Average Compressive Strength of Individual Unit) |
- |
5000 |
|
Compressive Strength |
9.5(PHYSICAL REQUIREMENTS -Water Absorption) |
- |
3000 |
|
Water Absorption |
9.6(PHYSICAL REQUIREMENTS -Drying Shrinkage) |
- |
7500 |
|
Drying Shrinkage |
9.7(PHYSICAL REQUIREMENTS -Moisture Movement) |
- |
3000 |
|
Moisture Movement |
15(Marking) |
- |
1000 |
|
Marking |
|
18 Dec, 2027 |
- - |
37 |
IS 280 (2006) |
Mild steel wire for general engineering purposes (Fourth Revision) |
All |
8000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 7 & Table 1(Diameter & Difference Between Two Reading On Any Two Diameters) |
- |
500 |
|
Dimension |
Cl 9(Tensile Test On UTM) |
- |
2000 |
|
Tensile |
Cl 13(Workmanship) |
- |
500 |
|
Freedom from defects |
Cl 11(Workmanship) |
- |
2000 |
|
Zinc Coating |
13(Freedom from defects) |
- |
500 |
|
Freedom from Defects |
7 & 8(Diameter) |
- |
500 |
|
Dimension |
7 & 8(Ovality) |
- |
500 |
|
Dimension |
9.2(Wrapping Test) |
- |
2000 |
|
Wrapping Test |
9.3(Bend test) |
- |
1500 |
|
Bend Test |
Cl 11(Workmanship) |
- |
500 |
|
Workmanship (IS 7887 : 1992) |
|
18 Dec, 2027 |
- - |
38 |
IS 3601 (2006) |
Steel tubes for mechanical and general engineering purposes - Specification (Second Revision) |
All |
12000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Material) |
- |
1000 |
|
Sulphur & Phosphorous |
13(Mechanical Testing) |
- |
12000 |
|
Mechanical (Tensile, Bend, Flattening, Crushing, Drift Expansion) |
6.0(Workmanship) |
- |
500 |
|
Freedom from Defects |
4.1(Sulphur-Percentage by mass) |
- |
500 |
|
Sulphur |
4.1(Phosphorus-Percentage by mass) |
- |
500 |
|
Phosphorous |
8.0(Straightness) |
- |
500 |
|
Dimension |
19.1.1, 24.1.1, 28.1.1, 33.1.1(Dimensions- Outside Dia) |
- |
500 |
|
Dimension |
19.1.2, 24.1.2, 28.1.2, 33.1.2(Dimensions- Thickness) |
- |
500 |
|
Dimension |
11.2(Surface Protection) |
- |
1000 |
|
Uniformity of Coating |
13.1.3(Tensile Strength) |
- |
5000 |
|
Tensile |
13.1.1(Yield Stress) |
- |
5000 |
|
Tensile |
13.1.2(Elongation) |
- |
5000 |
|
Tensile |
13.2(Flattening Test) |
- |
2000 |
|
Flattening |
13.4(Bend Test (Whole Tube)) |
- |
2000 |
|
Bend |
13.5(Drift Expansion Test) |
- |
2000 |
|
Drift Expansion |
13.6(Crush Test) |
- |
2000 |
|
Crushing |
13.3(Bend Test (Strip)) |
- |
2000 |
|
Bend |
19.1.3(Height of Internal Fin) |
- |
500 |
|
Dimension |
Cl. 10 Annex B Cl. 17, Cl. 19(Mass) |
- |
500 |
|
Mass |
Cl. 9(Length) |
- |
500 |
|
Dimension |
Cl. 10 Annex B Cl. 17, Cl. 19(Moment of inertia) |
- |
500 |
|
Dimension Geometric Properties |
Cl. 10 Annex B Cl. 17, Cl. 19(Radius of gyration) |
- |
50 |
|
Dimension Geometric Properties |
Cl. 10 Annex B Cl. 17, Cl. 19(Modulus of section) |
- |
500 |
|
Dimension Geometric Properties |
Cl. 10 Annex B Cl. 17, Cl. 19(Area of cross section) |
- |
500 |
|
Dimension Geometric Properties |
|
18 Dec, 2027 |
- - |
39 |
IS 15647 (2006) |
Hot rolled steel narrow width strip for welded tubes and pipes |
All |
11000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 8(UTM) |
- |
3000 |
|
Tensile |
Cl 9(Press) |
- |
1000 |
|
Bend |
Cl 11(Workmanship) |
- |
500 |
|
Freedom From Defects |
Cl 12(Length, Width & Thickness) |
- |
500 |
|
Dimesions |
Cl 13(Workmanship) |
- |
500 |
|
Freedom from Defects |
Cl. 12(Weight) |
- |
500 |
|
Weight |
Cl. 12(Edge Camber) |
- |
500 |
|
Dimension |
Cl. 12(Thickness) |
- |
500 |
|
Dimension |
Cl. 8.2 Table 3(Elongation) |
- |
3000 |
|
Elonagtion |
Cl. 8.2 Table 3(Yield Stress) |
- |
3000 |
|
Yield |
|
18 Dec, 2027 |
- - |
40 |
IS 4457 (2007) |
Ceramic unglazed vitreous acid resisting tiles - Specification (Second Revision) |
All |
40000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 5, Table 1 - iv -a (Resistance to Chemicals - Annex F) |
- |
10000 |
|
Resistance to Chemicals |
Cl. 5, Table 1 - iv -b (Resistance to conc. HNO3 and conc. H2SO4 - Annex G) |
- |
10000 |
|
Resistance to conc. HNO3 and conc. H2SO4 |
4.1(DIMENSIONS AND TOLERANCES- Size) |
- |
10000 |
|
All Dimensions |
4.2(DIMENSIONS AND TOLERANCES- Thickness) |
- |
10000 |
|
All Dimensions |
5-Table 1(i)-a(REQUIREMENTS-Dimensions and Surface Quality-Length) |
- |
11000 |
|
All Dimensions and Surface Quality |
5-Table 1(i)-a(REQUIREMENTS-Dimensions and Surface Quality-Width) |
- |
11000 |
|
All Dimensions and Surface Quality |
5-Table 1(i)-b(REQUIREMENTS-Dimensions and Surface Quality-Thickness) |
- |
11000 |
|
All Dimensions and Surface Quality |
5-Table 1(i)-c(REQUIREMENTS-Dimensions and Surface Quality-Straightness of sided) |
- |
11000 |
|
All Dimensions |
5-Table 1(i)-d(REQUIREMENTS-Dimensions and Surface Quality-Rectangularity) |
- |
10000 |
|
All Dimensions |
5-Table 1(i)-e(REQUIREMENTS-Dimensions and Surface Quality-Surface flatness-Centre curvature) |
- |
11000 |
|
All Dimensions and Surface Quality |
5-Table 1(i)-e(REQUIREMENTS-Dimensions and Surface Quality-Surface flatness-Edge curvature) |
- |
11000 |
|
All Dimensions and Surface Quality |
5-Table 1(i)-e(REQUIREMENTS-Dimensions and Surface Quality-Surface flatness-Warpage) |
- |
11000 |
|
All Dimensions and Surface Quality |
5-Table 1(ii)(REQUIREMENTS-Surface Quality) |
- |
1000 |
|
Surface Quality |
5-Table 1(iii)(REQUIREMENTS-Physical Properties-Water absorption by weigh(Average)) |
- |
10000 |
|
Water Absorption |
5-Table 1(iii)-a(REQUIREMENTS-Physical Properties-Water absorption by weigh(Indivisual)) |
- |
10000 |
|
Water Absorption |
5-Table 1(iii)-b-1(REQUIREMENTS-Physical Properties-Breaking strengrh(Thickness>=7.5mm)) |
- |
15000 |
|
Modulus of Rupture and Breaking Strength |
5-Table 1(iii)b-2(REQUIREMENTS-Physical Properties-Breaking strengrh(Thickness <7.5mm)) |
- |
15000 |
|
Modulus of Rupture and Breaking Strength |
5-Table 1(iii)-c(REQUIREMENTS-Physical Properties-Modulus of rupture(Average)) |
- |
15000 |
|
Modulus of Rupture and Breaking Strength |
5-Table 1(iii)-c(REQUIREMENTS-Physical Properties-Modulus of rupture(Individual)) |
- |
15000 |
|
Modulus of Rupture and Breaking Strength |
5-Table 1(iii)-d(REQUIREMENTS-Physical Properties-Abrusion resistance) |
- |
5000 |
|
Abrasion |
|
18 Dec, 2027 |
- - |
41 |
IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
- |
52500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking and instructions) |
- |
1000 |
|
Testing charges parameter wise |
8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
Testing charges parameter wise |
8.1.2(Protection against live parts in openings) |
- |
1000 |
|
Testing charges parameter wise |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
Testing charges parameter wise |
8.1.4(Protection against live parts against protective impedance) |
- |
3000 |
|
Testing charges parameter wise |
10.1(Power input) |
- |
3000 |
|
Testing charges parameter wise |
10.2(Current input) |
- |
3000 |
|
Testing charges parameter wise |
11.1(General) |
- |
1000 |
|
Testing charges parameter wise |
11.2(General) |
- |
1000 |
|
Testing charges parameter wise |
11.3(Heating) |
- |
6000 |
|
Testing charges parameter wise |
13.1(General) |
- |
1000 |
|
Testing charges parameter wise |
13.2(Leakage current at operating temperature) |
- |
5000 |
|
Testing charges parameter wise |
13.3(Electric Strength at operating temperature) |
- |
6000 |
|
Testing charges parameter wise |
14(Transient Over Voltages) |
- |
8000 |
|
Testing charges parameter wise |
15.0(General) |
- |
1000 |
|
Testing charges parameter wise |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
10000 |
|
Testing charges parameter wise |
15.2(Spillage Test) |
- |
3000 |
|
Testing charges parameter wise |
15.3(Humidity Test) |
- |
5000 |
|
Testing charges parameter wise |
16.0(General) |
- |
1000 |
|
Testing charges parameter wise |
16.1(General) |
- |
1000 |
|
Testing charges parameter wise |
16.2(Leakage Current (after Clause 15)) |
- |
5000 |
|
Testing charges parameter wise |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
6000 |
|
Testing charges parameter wise |
17(Over Load Protection of Transformers and associated circuits) |
- |
6000 |
|
Testing charges parameter wise |
18(Endurance Test requirements and tests) |
- |
1000 |
|
Testing charges parameter wise |
19(Abnormal Operation) |
- |
8000 |
|
Testing charges parameter wise |
20(Stability test) |
- |
2000 |
|
Testing charges parameter wise |
21(Mechanical Strength Test) |
- |
5000 |
|
Testing charges parameter wise |
22(Construction verification related test) |
- |
8000 |
|
Testing charges parameter wise |
23(General) |
- |
2500 |
|
Testing charges parameter wise |
24(Components) |
- |
2000 |
|
Testing charges parameter wise |
25(Supply connection and external flexible cords) |
- |
7000 |
|
Testing charges parameter wise |
26(Terminals for external conductors) |
- |
3000 |
|
Testing charges parameter wise |
27(Provision for earthing) |
- |
3000 |
|
Testing charges parameter wise |
28(Screw test and connections) |
- |
5000 |
|
Testing charges parameter wise |
29(clearance, creepage distances and solid insulation) |
- |
9000 |
|
Testing charges parameter wise |
30.1(Ball pressure test) |
- |
3000 |
|
Testing charges parameter wise |
30.2(Glow Wire Test) |
- |
3000 |
|
Testing charges parameter wise |
30.2(Needle Flame Test) |
- |
3000 |
|
Testing charges parameter wise |
31(Resistance to Rusting) |
- |
2000 |
|
Testing charges parameter wise |
32(Radiation Toxicity and Similar Hazards) |
- |
2000 |
|
Testing charges parameter wise |
|
18 Dec, 2027 |
- Exclusion
24 (Components)
19 (Abnormal Operation) |
42 |
IS 6240 (2008) |
Hot rolled steel plate (Up To 6 Mm) sheet and strip for the manufacture of low pressure liquefiable gas cylinders (Fourth Revision) |
All |
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 7(UTM) |
- |
3000 |
|
Tensile |
Cl 8(Press) |
- |
1000 |
|
Bend |
Cl 9(Strainage Embrittlement) |
- |
5000 |
|
Strainage Embrrittlement |
Cl 10(Erichsen Cupping) |
- |
3000 |
|
Cupping |
Cl 13(Length, Width & Thickness) |
- |
1000 |
|
Dimension |
6.1(Carbon %) |
- |
500 |
|
Carbon |
6.1(Manganese %) |
- |
500 |
|
Manganese |
6.1(Phosphorus %) |
- |
500 |
|
Phosphorous |
6.1(Sulphur %) |
- |
500 |
|
Sulphur |
6.1(Silicon %) |
- |
500 |
|
Silicon |
6.1( Aluminium %) |
- |
500 |
|
Aluminium |
6.1(Nitrogen%) |
- |
1500 |
|
Nitrogen |
Cl. 13(Out of square) |
- |
1000 |
|
Dimension |
Cl. 13(Flatness) |
- |
1000 |
|
Dimension |
Cl. 13(Camber) |
- |
1000 |
|
Dimension |
Cl. 13(Width) |
- |
1000 |
|
Dimension |
Cl. 13(Thickness) |
- |
1000 |
|
Dimension |
Cl. 12(Freedom from defects) |
- |
1000 |
|
Freedom from Defect |
Cl. 7.2 Table 3(Elongation) |
- |
3000 |
|
Elongation |
Cl. 7.2 Table 3(Yield Stress) |
- |
3000 |
|
Elongation |
|
18 Dec, 2027 |
- - |
43 |
IS 13488 (2008) |
Irrigation equipment - Emitting pipe systems - Specification (First Revision) |
NA |
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1.2 (Ref. Cl 4.1.b of IS 12786 : 1989)(Potyethylene - anti-oxidant) |
- |
1500 |
|
OK |
5.1.2 (Ref. Cl 4.1.c.i of IS 12786 : 1989)(Density) |
- |
1000 |
|
OK |
5.1.2 (Ref. Cl 4.1.c.ii of IS 12786 : 1989)(Toluene extract - Annex A of IS 12786:1989) |
- |
1500 |
|
OK |
5.1.2 (Ref. Cl 4.1.c.iii of IS 12786 : 1989)(Volatile matter - Annex B of IS 12786:1989) |
- |
1000 |
|
OK |
5.1.2 (Ref. Cl 4.1.c & 4.2.a of IS 12786 : 1989)(Carbon Black content - IS 2530 : 1963) |
- |
1500 |
|
OK |
8.1.2(Uniformity of Emission Rate for Unregulated Emitting Pipes) |
- |
5000 |
|
OK |
8.1.3(Uniformity of Emission Rate for Regulated Emitting Pipes) |
- |
5000 |
|
OK |
8.2(Emission Rate of Emitting Unit as a Function of Inlet Pressure) |
- |
5000 |
|
OK |
8.2.1(Unregu/Qt~d Emining Pipe) |
- |
5000 |
|
OK |
8.2.2(Regulated Emitting Pipes) |
- |
5000 |
|
OK |
8.3.1(Wall Thickness ofEmitting Pipe) |
- |
1000 |
|
OK |
8.3.2(Inside Diameter ofEmitting Pipe) |
- |
1000 |
|
OK |
8.3.3(Flow Paths in Emitting Unit) |
- |
1000 |
|
OK |
8.3.4(Spacing ofEmitter Units) |
- |
1000 |
|
OK |
8.4.1(Resistance to Hydrostatic Pressure at Ambient Temperature) |
- |
5000 |
|
OK |
8.4.2(Resistance to Hydrostatic Pressure at Elevated Temperature) |
- |
5000 |
|
OK |
8.5(Resistance to Tension at Elevated Temperature) |
- |
5000 |
|
OK |
8.5(Resistance to Tension at Elevated Temperature) |
- |
5000 |
|
OK |
8.5(Resistance to Tension at Elevated Temperature) |
- |
5000 |
|
OK |
8.6(Resistance to Pull Out of Joints Between Fitting and Emitting
IS 13479) |
- |
2000 |
|
OK |
8.7.1(Resistance of PE Emitting Pipe to
Environmental Stress Cracking -Acceptance Test
Annex D of IS 12786) |
- |
5000 |
|
OK |
8.7.2(Resistance of PE Emitting Pipe to
Environmental Stress Cracking - Type Test
Annex D of IS 12786) |
- |
5000 |
|
OK |
8.8(Determination of Emitting Unit Exponent) |
- |
3000 |
|
OK |
|
18 Dec, 2027 |
- - |
44 |
IS 15801 (2008) |
Polypropylene - Random copolymer pipes for hot and cold water supplies - Specification |
NA |
150000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 7(Dimensions Of Pipes) |
- |
3000 |
|
ok |
Cl 8(Visual Appearance) |
- |
500 |
|
ok |
Cl 9.1(Hydraulic Characteristics) |
- |
15000 |
|
ok |
Cl 9.2(Fusion Compatibility) |
- |
2000 |
|
ok |
Cl 9.3(Reversion Test ) |
- |
5000 |
|
ok |
Cl 9.4 & Annex B(Impact Strength) |
- |
5000 |
|
ok |
Cl 9.5(Density) |
- |
1000 |
|
ok |
Cl 9.6(Melt Flow Rate) |
- |
2000 |
|
ok |
Cl 9.7(Carbon Black Content & Dispersion) |
- |
2000 |
|
ok |
Cl 9.8(Thermal Stability By Hydrostatic Pressure Testing) |
- |
125000 |
|
ok |
Cl 9.9(Opacity) |
- |
2000 |
|
ok |
|
18 Dec, 2027 |
- - |
45 |
IS 278 (2009) |
Galvanized steel barbed wire for fencing - Specification (Fourth Revision) |
All |
4500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5 Table-1(Sizes Diameter of Line wire) |
- |
1000 |
|
NA |
5 Table-1(Sizes Diamater of Point wire) |
- |
1000 |
|
Dimension |
5 Table-1(Sizes Mass of Completed barbed wire) |
- |
1000 |
|
Mass |
5 Table-1(Sizes Distance between two barbs) |
- |
1000 |
|
Dimension |
5 Table-1(Sizes No. of Lays between the two consequtive barbs) |
- |
1000 |
|
Dimension |
9.1(Freedom from defects) |
- |
1000 |
|
Freedom from Defects |
12.1(Tensile Strength) |
- |
1500 |
|
Tensile Test |
12.1(Breaking load) |
- |
1500 |
|
Breaking Load |
12.3(Ductility) |
- |
1500 |
|
Wrapping |
12.2.1(Mass of zinc coating (line wire)) |
- |
1500 |
|
Mass of Zinc Coating |
12.2.2(Mass of zinc coating (point wire)) |
- |
1500 |
|
Uniformity of Zinc Coating |
Cl. 7.1(General) |
- |
1000 |
|
General |
Cl. 7.2(Finishing of Barbs) |
- |
1000 |
|
Finishing of Barbs |
Cl. 7.2(Length of Barbs) |
- |
1000 |
|
Dimension |
Cl. 7.2(Cut Angle) |
- |
1000 |
|
Dimension |
4(Type A/Type B) |
- |
1000 |
|
Type A/Type B |
|
18 Dec, 2027 |
- - |
46 |
IS 3502 (2009) |
Steel chequered plates (Third Revision) |
All |
11010 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5(Workmanship) |
- |
1000 |
|
NA |
Cl 8(UTM) |
- |
7500 |
|
Tensile Test |
Cl 9(Press) |
- |
1000 |
|
Bend Test |
Cl 10(Length, Width, Thickness & Chequered Height) |
- |
1000 |
|
Dimenions |
Cl. 11(Weight) |
- |
1000 |
|
Weight |
Cl. 10(Thickness) |
- |
1000 |
|
Dimension |
Cl. 10(Width) |
- |
1000 |
|
Dimension |
Cl.8(Elongation) |
- |
7500 |
|
Elongation |
Cl.8(Yield Stress) |
- |
7500 |
|
Yield Stress |
Cl 10(Length, Width, Thickness & Chequered Height) |
- |
1000 |
|
Chequered Height |
|
18 Dec, 2027 |
- - |
47 |
IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
60000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
1.5(Components) |
- |
1000 |
|
Testing charges parameter wise |
1.6(Power interface .) |
- |
1000 |
|
Testing charges parameter wise |
1.7(Markings and instructions) |
- |
1000 |
|
Testing charges parameter wise |
2.1(Protection from electric shock and energy hazards) |
- |
5000 |
|
Testing charges parameter wise |
2.2(SELV circuits) |
- |
3000 |
|
Testing charges parameter wise |
2.3(TNV circuits) |
- |
5000 |
|
Testing charges parameter wise |
2.4(Limited current circuits) |
- |
5000 |
|
Testing charges parameter wise |
2.5(Limited power sources .) |
- |
5000 |
|
Testing charges parameter wise |
2.6(Provisions for earthing and bonding) |
- |
3000 |
|
Testing charges parameter wise |
2.7(Overcurrent and earth fault protection in primary circuits) |
- |
2000 |
|
Testing charges parameter wise |
2.8(Safety interlocks) |
- |
2000 |
|
Testing charges parameter wise |
2.9(Electrical insulation) |
- |
5000 |
|
Testing charges parameter wise |
2.10(Clearances, creepage distances and distances through insulation) |
- |
10000 |
|
Testing charges parameter wise |
3.1(General) |
- |
2000 |
|
Testing charges parameter wise |
3.2(Connection to a mains supply) |
- |
6000 |
|
Testing charges parameter wise |
3.3(Wiring terminals for connection of external conductors) |
- |
3000 |
|
Testing charges parameter wise |
3.4(Disconnection from the mains supply) |
- |
1000 |
|
Testing charges parameter wise |
3.5(Interconnection of equipment) |
- |
1000 |
|
Testing charges parameter wise |
4.1(Stability) |
- |
2000 |
|
Testing charges parameter wise |
4.2(Mechanical strength) |
- |
5000 |
|
Testing charges parameter wise |
4.3(Design and construction) |
- |
3000 |
|
Testing charges parameter wise |
4.4(Protection against hazardous moving parts) |
- |
2000 |
|
Testing charges parameter wise |
4.5(Thermal requirements) |
- |
4000 |
|
Testing charges parameter wise |
4.6(Openings in enclosures) |
- |
3000 |
|
Testing charges parameter wise |
4.7(Resistance to fire) |
- |
5000 |
|
Testing charges parameter wise |
5.1(Touch current and protective conductor curren) |
- |
3000 |
|
Testing charges parameter wise |
5.2(Electric strength) |
- |
5000 |
|
Testing charges parameter wise |
5.3(Abnormal operating and fault conditions) |
- |
6000 |
|
Testing charges parameter wise |
6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
2000 |
|
Testing charges parameter wise |
6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
5000 |
|
Testing charges parameter wise |
6.3(Protection of the telecommunication wiring system from overheating) |
- |
5000 |
|
Testing charges parameter wise |
7.1(General) |
- |
1000 |
|
Testing charges parameter wise |
7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
1000 |
|
Testing charges parameter wise |
7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
5000 |
|
Testing charges parameter wise |
7.4(Insulation between primary circuits and cable distribution systems) |
- |
7000 |
|
Testing charges parameter wise |
|
18 Dec, 2027 |
- - |
48 |
IS 15914 (2011) |
High tensile strength flat rolled steel plate (Up To 6 Mm), sheet and strip for the manufacture of welded gas cylinder - Specification |
All |
12750 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 7(UTM) |
- |
10000 |
|
NA |
Cl 9(Workmanship) |
- |
1000 |
|
Freedom from Defects |
Cl 10(Length, Width & Thickness) |
- |
1000 |
|
Dimensions |
6.0(MICRO ALLOYING) |
- |
500 |
|
Micro Alloying |
6.0(ALUMINIUM) |
- |
100 |
|
Aluminium |
6.0(SILICON) |
- |
500 |
|
Silicon |
6.0(MANGANESE) |
- |
500 |
|
Manganese |
6.0(PHOSPHORUS) |
- |
500 |
|
Phosphorous |
6.0(SULPHUR) |
- |
500 |
|
Sulphur |
6.0(CARBON) |
- |
500 |
|
Carbon |
6.0(NITROGEN) |
- |
2000 |
|
Nitrogen |
Cl. 10(Mass) |
- |
1000 |
|
Weight |
Cl. 10(Out of square) |
- |
1000 |
|
Dimension |
Cl. 10(Flatness) |
- |
1000 |
|
Dimension |
Cl. 10(Camber) |
- |
1000 |
|
Dimension |
Cl. 10(Width) |
- |
1000 |
|
Dimension |
Cl. 10(Thickness) |
- |
1000 |
|
Dimension |
Cl. 7 Table 3(Elongation) |
- |
10000 |
|
Elongation |
Cl. 7 Table 3(Yield Stress) |
- |
10000 |
|
Yield |
|
18 Dec, 2027 |
- - |
49 |
IS 299 (2012) |
Alumino - Ferric - Specification (Fifth Revision) |
- |
12000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
1 (i) Table 1( Insouble matter, Grade 4, A-3) |
- |
1500 |
|
- |
1 (ii) Table 1(Soluble iron compound (as Fe2+ and Fe3+), Grade 4, A-4) |
- |
1500 |
|
- |
1 (iii) Table 1(Water soluble aluminium compounds (as Al2O3), Grade 4, A-5) |
- |
1500 |
|
- |
1 (iv) Table 1(pH (of 5 percent aqueous solution), Grade 4, A-6) |
- |
1000 |
|
- |
1 (v) Table 1(Free acidity (as H2SO4)/Basicity (as Al2O3), Grade 4, A-7) |
- |
1500 |
|
- |
1 (vi) Table 1( Lead (as Pb), Grade 4, A-8) |
- |
1500 |
|
- |
1 (vii) Table 1(Arsenic (as As2O3), Grade 4, A-9) |
- |
1500 |
|
- |
1 (viii) Table 1(Mercury (as Hg), Grade 4, A-10) |
- |
1500 |
|
- |
1 (ix) Table 1(Manganese (as Mn), Grade 4, A-11) |
- |
1500 |
|
- |
1 (x) Table 1(Chromium (as Cr), Grade 1, A-12) |
- |
1500 |
|
- |
1 (xi) Table 1(Cadmium (as Cd), Grade 4, A-13) |
- |
1500 |
|
- |
1 (xii) Table 1(Selenium (as Se), Grade 4, A-14) |
- |
1500 |
|
- |
1 (xiii) (a) Table 1(Organic impurities:Phenolic compounds (as C6H5OH), Garde 4, A-15) |
- |
1500 |
|
- |
1 (xiii) (b) Table 1(Anionic detergents (as MASS), Garde 1, A-16) |
- |
1500 |
|
- |
|
18 Dec, 2027 |
- - |
50 |
IS 1237 (2012) |
Cement Concrete Flooring Tiles - Specification |
All |
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 7.1(Length, Breadth, Minimum thickness, Difference in length of side between the longest side and shorterst side, Half tiles, Difference in Thickness between the thickest and thinnest tile, Thickness of wearing layer) |
- |
750 |
|
All Dimension |
Cl 12.2(Concavity & Convexity ) |
- |
750 |
|
All Dimension |
Cl 12.3(The Maximum gap between the arms of the square and the edge of the title shall notexceed 2 percent of the length.) |
- |
750 |
|
All Dimension |
Cl 12.4(Shall not exceed 1 percent of the length of the edge.) |
- |
750 |
|
All Dimension |
Cl 12.5(Water absorption) |
- |
1000 |
|
Water absorption |
Cl 12.6(Wet transverse strength ) |
- |
2000 |
|
Wet transverse strength |
Cl 12.7(Resistance to wear) |
- |
5000 |
|
Resistance to wear |
Cl 11(Suface Finish) |
- |
500 |
|
Surface Finish |
Cl 7.1(Length, Breadth, Minimum thickness, Difference in length of side between the longest side and shorterst side, Half tiles, Difference in Thickness between the thickest and thinnest tile, Thickness of wearing layer) |
- |
750 |
|
All Dimension |
|
18 Dec, 2027 |
- - |
51 |
IS 2830 (2012) |
Carbon steel cast billet ingots, billets, blooms and slabs for re-rolling into steel for general structural purposes - Specification (Third Revision) |
All |
8600 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 9(Workmanship) |
- |
500 |
|
NA |
Cl 10.1(Workmanship) |
- |
500 |
|
Macro Examination |
Cl 10.2(Workmanship) |
- |
500 |
|
Bend |
Cl 10.3(Workmanship) |
- |
500 |
|
Camber |
Cl 11(Length, Width & Thickness) |
- |
500 |
|
Dimension |
6.1(Carbon %) |
- |
500 |
|
Carbon |
6.1(Manganese %) |
- |
500 |
|
Manganese |
6.1(Phosphorus %) |
- |
500 |
|
Phosphorous |
6.1(Sulphur %) |
- |
500 |
|
Sulphur |
6.1(Silicon %) |
- |
500 |
|
Silicon |
6.1( Nitrogen%) |
- |
500 |
|
Nitrogen |
6.1( Copper %) |
- |
100 |
|
Copper |
6.1( Aluminium %) |
- |
100 |
|
Aluminium |
6.1( Nb) |
- |
100 |
|
Niobium |
6.1(V) |
- |
100 |
|
Vanadium |
6.1( Ti) |
- |
100 |
|
Titanium |
6.1(Cr) |
- |
100 |
|
Chromium |
6.1(Mo) |
- |
100 |
|
Moybdenum |
6.1(Ni) |
- |
100 |
|
Nickle |
10.1 (a)(Macro-examination) |
- |
500 |
|
Macro Examination |
Cl. 10.2(Bend) |
- |
500 |
|
Dimension |
Cl. 10.3(Camber) |
- |
500 |
|
Dimension |
11(Width) |
- |
500 |
|
Dimension |
11(Thickness) |
- |
500 |
|
Dimension |
Cl. 10.1 (b)(Sulphur Print) |
- |
8000 |
|
Sulphur Print |
Cl. 11.2(Out of Squareness) |
- |
500 |
|
Dimension |
|
18 Dec, 2027 |
- - |
52 |
IS 2831 (2012) |
Carbon steel cast billet ingots, billets, blooms and slabs for re-rolling into structural steel (Ordinary Quality) - Specification (Fourth Revision) |
All |
10325 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9( FREEDOM FROM DEFECTS) |
- |
500 |
|
NA |
10.1.a)( Macro examination IS 11371) |
- |
500 |
|
Macro Examination |
10.1.b)( Sulphur print tests IS 12037) |
- |
8000 |
|
Sulphur Print |
11 & 12(DIMENSIONS and Tolerances) |
- |
500 |
|
Dimension |
Cl. 6.1, Table 1(Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Carbon |
Cl. 6.1, Table 1(Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Manganese |
Cl. 6.1, Table 1(Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Sulphur |
Cl. 6.1, Table 1(Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Phosphorous |
Cl. 6.1, Table 1(Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Silicon |
Cl. 6.1, Table 1(Aluminium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
100 |
|
Aluminium |
Cl. 6.1, Table 1(Nitrogen- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1500 |
|
Nitrogen |
Cl. 6.1, Table 1(Copper- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
100 |
|
Copper |
Cl. 6.1, Table 1(Niobium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
100 |
|
Niobium |
Cl. 6.1, Table 1(Vanadium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
100 |
|
Vanadium |
Cl. 6.1, Table 1(Titanium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
100 |
|
Titanium |
|
18 Dec, 2027 |
- - |
53 |
IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
- |
21800 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General Test Requireements) |
- |
1000 |
|
Testing Charges As per parameter |
5(Classification of Luminaires') |
- |
1000 |
|
Testing Charges As per parameter |
6.0(Marking) |
- |
3000 |
|
Testing Charges As per parameter |
7.0(Construction) |
- |
10000 |
|
Testing Charges As per parameter |
8.0(Creepage Distance and Clearances) |
- |
6000 |
|
Testing Charges As per parameter |
9.0(Provision for earthing) |
- |
5000 |
|
Testing Charges As per parameter |
10.0(Terminals) |
- |
9000 |
|
Testing Charges As per parameter |
11.0(External & Internal Wiring) |
- |
6000 |
|
Testing Charges As per parameter |
12.0(Protection against electric shock) |
- |
5000 |
|
Testing Charges As per parameter |
13.0(Endurance Tests and Thermal Tests) |
- |
14000 |
|
Testing Charges As per parameter |
14.0(Resistance to Dust & Moisture) |
- |
15000 |
|
Testing Charges As per parameter |
15.0(Insulation Resistance and Electric Strength) |
- |
10000 |
|
Testing Charges As per parameter |
16.0(Resistance to Heat , fire and tracking) |
- |
12000 |
|
Testing Charges As per parameter |
|
18 Dec, 2027 |
- - |
54 |
IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
- |
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking) |
- |
1000 |
|
- |
8(Protection against accidental contact with live parts) |
- |
5000 |
|
- |
9(Terminals) |
- |
8000 |
|
- |
10(PROVISION FOR EARTHING) |
- |
3000 |
|
- |
11(MOISTURE RESISTANCE) |
- |
9000 |
|
- |
12(Electric Strength) |
- |
5000 |
|
- |
13(Thermal endurance test for winding of ballasts) |
- |
1000 |
|
- |
14(Fault conditions) |
- |
8000 |
|
- |
15(Transformer heating) |
- |
9000 |
|
- |
16(Construction) |
- |
6000 |
|
- |
17(Creepage distance and clearances) |
- |
5000 |
|
- |
18(Screws, current carrying parts and connections) |
- |
5000 |
|
- |
19(Resistance to heat, fire and tracking) |
- |
10000 |
|
- |
20(Resistance to corrosion) |
- |
5000 |
|
- |
|
18 Dec, 2027 |
- - |
55 |
IS 15961 (2012) |
Hot dip aluminium - Zinc alloy metallic coated steel strip and sheet (Plain) |
All |
7485 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 8(UTM) |
- |
5000 |
|
NA |
Cl 9 & Table 2(Workmanship) |
- |
2000 |
|
Mass of Zinc Coating |
Cl 10(Coating Adhesion ) |
- |
2000 |
|
Coating Adhesion |
Cl 11(Workmanship) |
- |
500 |
|
Freedom From Defects |
Cl 12(Weight) |
- |
500 |
|
Weight |
Cl 13(Length, Width, Thickness, Camber, Deviation From Squareness & Deviation From Flatness) |
- |
1000 |
|
Dimension |
|
18 Dec, 2027 |
- - |
56 |
IS 15962 (2012) |
Structural steels for buildings and structures with improved seismic resistance |
All |
40000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 6(Freedom from Defects) |
- |
2000 |
|
Freedom from Defects |
Cl 10(Tensile Test) |
- |
25000 |
|
Tensile Test |
Cl 11(Impact Test) |
- |
7500 |
|
Impact Test |
Cl 13(Dimensions) |
- |
2000 |
|
Dimensions |
Cl 16(Mass) |
- |
500 |
|
Mass |
Clauses 7, 8.1 & .2, Table- 1(E250S, C) |
- |
100 |
|
Carbon |
Clauses 7, 8.1 & .2, Table- 1(E250S, Mn ) |
- |
100 |
|
Manganese |
Clauses 7, 8.1 & .2, Table- 1(E250S, P) |
- |
100 |
|
Phosphorous |
Clauses 7, 8.1 & .2, Table- 1(E250S, S) |
- |
100 |
|
Sulphur |
Clauses 7, 8.1 & .2, Table- 1(E250S, Si) |
- |
100 |
|
Silicon |
Clauses 7, 8.1 & .2, Table- 1(E250S, CE) |
- |
500 |
|
Carbon Equivalent |
Clauses 7, 8.1 & .2, Table- 1(E300S, C) |
- |
100 |
|
Carbon |
Clauses 7, 8.1 & .2, Table- 1(E300S, Mn) |
- |
100 |
|
Manganese |
Clauses 7, 8.1 & .2, Table- 1(E300S, P) |
- |
100 |
|
Phosphorous |
Clauses 7, 8.1 & .2, Table- 1(E300S, S) |
- |
100 |
|
Sulphur |
Clauses 7, 8.1 & .2, Table- 1(E300S, Si) |
- |
100 |
|
Silicon |
Clauses 7, 8.1 & .2, Table- 1(E300S, CE) |
- |
500 |
|
Carbon Equivalent |
Clauses 7, 8.1 & .2, Table- 1(E350S, C) |
- |
100 |
|
Carbon |
Clauses 7, 8.1 & .2, Table- 1(E350S, Mn) |
- |
100 |
|
Manganese |
Clauses 7, 8.1 & .2, Table- 1(E350S, P) |
- |
100 |
|
Phosphorous |
Clauses 7, 8.1 & .2, Table- 1(E350S, S) |
- |
100 |
|
Sulphur |
Clauses 7, 8.1 & .2, Table- 1(E350S, Si) |
- |
100 |
|
Silicon |
Clauses 7, 8.1 & .2, Table- 1(E450S, C) |
- |
100 |
|
Carbon |
Clauses 7, 8.1 & .2, Table- 1(E450S, Mn) |
- |
100 |
|
Manganese |
Clauses 7, 8.1 & .2, Table- 1(E450S, P) |
- |
100 |
|
Phosphorous |
Clauses 7, 8.1 & .2, Table- 1(E450S, S) |
- |
100 |
|
Sulphur |
Clauses 7, 8.1 & .2, Table- 1(E450S, Si) |
- |
100 |
|
Silicon |
Clauses 7, 8.1 & .2, Table- 1(E450S, CE) |
- |
500 |
|
Carbon Equivalent |
Clauses 7, 8.1 & .2, Table- 1(E350S, CE) |
- |
500 |
|
Carbon Equivalent |
|
18 Dec, 2027 |
- - |
57 |
IS 15997 (2012) |
Low nickel austenitic stainless steel sheet and strip for utensils and kitchen appliances - Specification |
All |
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 8.1, 8.1.1 & 10.1 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Carbon |
Cl. 8.1, 8.1.1 & 10.1 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Silicon |
Cl. 8.1, 8.1.1 & 10.1 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Manganese |
Cl. 8.1, 8.1.1 & 10.1 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1500 |
|
Nickle |
Cl. 8.1, 8.1.1 & 10.1 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
750 |
|
Chromium |
Cl. 8.1, 8.1.1 & 10.1 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Suphur |
Cl. 8.1, 8.1.1 & 10.1 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
Phosphorous |
Cl. 8.1, 8.1.1 & 10.1 Table 1(Copper -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
750 |
|
Copper |
Cl. 8.1, 8.1.1 & 10.1 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1500 |
|
Nitrogen |
6(Freedom From Defects) |
- |
500 |
|
Freedom from Defects |
9.3(Tensile Test-1608:Part 1) |
- |
10000 |
|
Tensile Test |
9.3, Table 3 (Yield Strength, Mpa) |
- |
10000 |
|
Tensile |
9.3, Table 3 (Elongation, %) |
- |
10000 |
|
Tensile |
9.4(Erichsen Cupping Test,(Average depth of cupping) mm) |
- |
2000 |
|
Cupping |
12(Dimensions) |
- |
1000 |
|
Dimensions |
14.1(Thickness,mm) |
- |
1000 |
|
Dimensions |
14.2( Width, mm) |
- |
1000 |
|
Dimensions |
14.3(Length, mm) |
- |
1000 |
|
Dimensions |
14.4(Flatness, mm) |
- |
1000 |
|
Dimensions |
14.5(Camber, mm) |
- |
1000 |
|
Dimensions |
|
18 Dec, 2027 |
- - |
58 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
48000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking) |
- |
1000 |
|
- |
6(Interchangeability) |
- |
5000 |
|
- |
7(Protection against accidental contact with live parts) |
- |
5000 |
|
- |
8(Insulation Resistance and Electric Strength) |
- |
10000 |
|
- |
9(MECHANICAL STRENGTH) |
- |
5000 |
|
- |
10(cap temperature) |
- |
5000 |
|
- |
11(Resistance to Heat) |
- |
5000 |
|
- |
12(Resistance to Flame and Ignition) |
- |
4000 |
|
- |
13(Fault conditions) |
- |
9000 |
|
- |
14(Creepage distance and clearances) |
- |
5000 |
|
- |
|
18 Dec, 2027 |
- - |
59 |
IS 3812 (Part 1) (2013) |
Pulverized fuel ash - Specification: Part 1 For use as pozzolana in cement, cement mortar and concrete |
- |
17250 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1-Table 2(i)(PHYSICAL REQUIREMENTS-Fineness) |
- |
2000 |
|
NA |
7.1-Table 2(ii)(PHYSICAL REQUIREMENTS-Particles retained on 45 micron IS sieve) |
- |
2000 |
|
PHYSICAL REQUIREMENTS-Particles retained on 45 micron IS sieve |
7.1-Table 2(iii)(PHYSICAL REQUIREMENTS-Average compressive strength) |
- |
7500 |
|
PHYSICAL REQUIREMENTS-Average compressive strength |
7.1-Table 2(iv)(PHYSICAL REQUIREMENTS-Compressive strength at 28 days) |
- |
7500 |
|
PHYSICAL REQUIREMENTS- all Compressive strength at 28 days |
7.1-Table 2(v)(PHYSICAL REQUIREMENTS-Soundness by autoclave test ) |
- |
3000 |
|
PHYSICAL REQUIREMENTS-Soundness by autoclave test |
Cl. 6.1, Table 1 - i(Silicon dioxide (SiO2) plus aluminium oxide (Al2O3) plus ironoxide (Fe2O3) - IS 1727) |
- |
5000 |
|
Silicon dioxide (SiO2) plus aluminium oxide (Al2O3) plus ironoxide (Fe2O3) - IS 1727 |
Cl. 6.1, Table 1 - ii(Silicon dioxide (SiO2) - IS 1727) |
- |
1500 |
|
Silicon dioxide (SiO2) - IS 1727 |
Cl. 6.1, Table 1 - iii(Reactive Silica - Annex B) |
- |
1500 |
|
Reactive Silica - Annex B |
Cl. 6.1, Table 1 - iv(Magnesium oxide (MgO) - IS 1727) |
- |
1500 |
|
Magnesium oxide (MgO) - IS 1727 |
Cl. 6.1, Table 1 - v( Total sulphur as sulphur trioxide (SO3) - IS 1727) |
- |
1500 |
|
Total sulphur as sulphur trioxide (SO3) - IS 1727 |
Cl. 6.1, Table 1 - vi( Available alkalis as equivalent sodium oxide (Na2O) - Annex C) |
- |
5000 |
|
Available alkalis as equivalent sodium oxide (Na2O) - Annex C |
Cl. 6.1, Table 1 - vii( Total Chlorides - IS 4032) |
- |
3000 |
|
Total Chlorides - IS 4032 |
Cl. 6.1, Table 1 - viii( Loss on ignition - IS 1727) |
- |
3000 |
|
Loss on ignition |
Cl. 6.2(Moisture content of the fly ash when supplied in dry condition - Annex D) |
- |
2000 |
|
Moisture content of the fly ash when supplied in dry condition |
5.1, 7.1, table-2, iii(Lime reacitivity) |
- |
10000 |
|
Testing Charges As per Parameter |
|
18 Dec, 2027 |
- - |
60 |
IS 3812 : Part 2 (2013) |
Pulverized Fuel Ash - Part 2 : For Use as Admixture in Cement Mortar and Concrete |
- |
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1, Table 1(Fineness — Specific surface in m2 /kg) |
- |
2000 |
|
Fineness — Specific surface |
7.1, Table 1(Particles retained on 45 micron IS sieve (wet sieving)) |
- |
2000 |
|
Particles retained on 45 micron IS sieve (wet sieving) |
7.1, Table 1(Soundnes) |
- |
2000 |
|
Soundness |
5.1, 6.1, Table 1(Silicon dioxide (SiO2 ) plus aluminium oxide (Al2O3 ) plus iron oxide (Fe2O3 )) |
- |
5000 |
|
Silicon dioxide (SiO2 ) plus aluminium oxide (Al2O3 ) plus iron oxide (Fe2O3 ) |
5.1, 6.1, Table 1(Silicon dioxide (SiO2 )) |
- |
1500 |
|
Silicon dioxide (SiO2 ) |
5.1, 6.1, Table 1(Magnesium oxide (MgO) |
- |
1500 |
|
Magnesium oxide |
5.1, 6.1, Table 1(Total sulphur as sulphur trioxide (SO3) |
- |
1500 |
|
Total sulphur as sulphur trioxide |
5.1, 6.1, Table 1(Available alkalies as equivalent sodium oxide (Na2O)) |
- |
1500 |
|
Available alkalies as equivalent sodium oxide |
5.1, 6.1, Table 1(Total chlorides) |
- |
5000 |
|
Total chlorides |
5.1, 6.1, Table 1(Loss on ignition) |
- |
3000 |
|
Loss on ignition |
6.2(moisture content) |
- |
2000 |
|
moisture content |
Clauses 5.1 & 7.1 Table No. 2, SI No. (i)
(Fineness- Specific surface by blaine's method) |
- |
2000 |
|
- |
Clauses 5.1 & 7.1 Table No. 2, SI No. (ii)
(Particles retained on 45 micron IS Sieve (we sieving)) |
- |
2000 |
|
- |
Clauses 5.1 & 7.1 Table No. 2, SI No. (iii)
(Soundness by autoclave test - Expansion of specimen) |
- |
2000 |
|
- |
|
18 Dec, 2027 |
- - |