| 151 |
IS 10322 : Part 5 : Sec 4 (1987) |
Specification for luminaires: Part 5 particular requirements: Sec 4 portable general purpose luminaires |
- |
60000 View breakup
Rs. 60,000/-(Except Vibration Test)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
500 |
|
NA |
| 6(Construction) |
- |
27880 |
|
Above test charges included charges of CONSTRUCTION, TERMINALS, EXTERNAL & INTERNAL WIRING: 2000, charges of vibration test: 25880.
Total test charges: (2000+25880)=27880. |
| 7(Creepage Distance
And Clearances) |
- |
500 |
|
NA |
| 8(Provision for
Earthing) |
- |
500 |
|
NA |
| 9(Terminals) |
- |
0 |
|
NA |
| 10(External &
Internal Wiring) |
- |
0 |
|
NA |
| 11(Protection Against
Electric Shock ) |
- |
500 |
|
NA |
| 13.4(Endurance Test
and Thermal test) |
- |
17600 |
|
Above test charges included charges of endurance test: 11600, charges of thermal normal test: 3000, charges of thermal abnormal test: 3000.
Total test charges=(11600+3000+3000)= 17600. |
| 13.5(Resistance To
Dust & Moisture) |
- |
9000 |
|
Above test charges included charges of IP1X/2X/3X/4X: 1500, charges of IPX1/X2: 2000, charges of RESISTANCE TO MOISTURE: 5500.
Total test charges=(1500+2000+5500)=9000 |
| 13.6(Insulation Resistance
and Electric Strength) |
- |
1000 |
|
NA |
| 13.7(Resistance to Heat,
Fire & Tracking) |
- |
12070 |
|
Above test charges included charges of RESISTANCE TO HEAT: 1500, charges of NEEDLE FLAME TEST: 3500, charges of GLOW WIRE TEST: 5000, charges of RESISTANCE TO TRACKING: 2070.
Total test charges= (1500+3500+5000+2070)= 12070 |
| 13.8(Photometric Test) |
- |
20000 |
|
NA |
| 13.3(Mechanical
Strength Test ) |
- |
0 |
|
NA |
| Cl. No. 13.2(Visual inspection) |
- |
0 |
|
NA |
|
30 Nov, 2028 |
- - |
| 152 |
IS 1554 : Part 2 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 2 for working voltages from 3.3 kV up to and including 11 kV (Second Revision) |
- |
275100 View breakup
Rs. 2,28,450/- for 1 Core (upto 11 kV) ;
Rs. 2,75,100/- for 3 Core (upto 11 kV) ;
Multicore cables: additional charges Rs. 500/- per core per test.
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 18.1 a) 1)(Tests on Conductor : Annealing test (for copper)) |
- |
900 |
|
NA |
| 18.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
900 |
|
NA |
| 18.1 a) 3)(Tests on Conductor : Wrapping test ( for aluminium)) |
- |
500 |
|
NA |
| 18.1 a)4)(Tests on conductor : Conductor resistance test - Main conductor ) |
- |
1300 |
|
NA |
| 18.1 d) 1)(Phyaical tests for insulation : Tensile Test) |
- |
2000 |
|
NA |
| 18.1 d) 5)( Loss of mass in air oven- Insulation ) |
- |
8600 |
|
NA |
| 11.3(INSULATION : Tolerance on Thickness of Insulation) |
- |
1300 |
|
NA |
| 11.2(INSULATION : Thickness of Insulation) |
- |
0 |
|
NA |
| 15.4(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
0 |
|
NA |
| 16.3(Armouring : Dimensions -Wire Diameter) |
- |
555.55 |
|
NA |
| 16.3(Armouring : Dimensions -Formed wire ) |
- |
555.55 |
|
NA |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
555.55 |
|
NA |
| 13.6 b)(ARMOURING: Elongation ) |
- |
555.55 |
|
NA |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
555.55 |
|
NA |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
555.55 |
|
NA |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
555.55 |
|
NA |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
555.55 |
|
NA |
| 13.6 g)(ARMOURING: Resistivity) |
- |
555.55 |
|
NA |
| 17.3.1(Thickness of Outer Sheath : Unarmoured Cables) |
- |
1300 |
|
NA |
| 17.3.2(Thickness of Outer Sheath : Armoured Cables) |
- |
1300 |
|
NA |
| 18.1 a)4)(Resistance test - Neutral conductor ) |
- |
1300 |
|
NA |
| 18.1 d) 1)(Phyaical tests for insulation : Elongation ) |
- |
2000 |
|
NA |
| 18.1 d) 2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
8600 |
|
NA |
| 18.1 d) 2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
0 |
|
NA |
| 18.1 d) 2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
8600 |
|
NA |
| 18.1 d) 2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
0 |
|
NA |
| 18.1 d) 2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
0 |
|
NA |
| 18.1 d) 2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
0 |
|
NA |
| 18.1 d) 3)(Phyaical tests for insulation : Shrinkage ) |
- |
1300 |
|
NA |
| 18.1 d) 3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
0 |
|
NA |
| 18.1 d) 3)(Phyaical tests for Sheath : Shrinkage ) |
- |
1300 |
|
NA |
| 18.1 d) 3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
0 |
|
NA |
| 18.1 d) 4)(Hot deformation : Insulation ) |
- |
1900 |
|
NA |
| 18.1 d) 5)( Loss of mass in air oven- sheath ) |
- |
8600 |
|
NA |
| 18.1 d) 6)(Heat shock test- Insulation ) |
- |
1300 |
|
NA |
| 18.1 d) 6)(Heat shock test- sheath ) |
- |
1300 |
|
NA |
| 18.1 d) 7)(Thermal stability- insulation ) |
- |
1900 |
|
NA |
| 18.1 d) 8)(Water absorption (gravimetric)(for insulation, where applicable)) |
- |
10300 |
|
NA |
| 18.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
2700 |
|
NA |
| 18.1 e)(Insulation resistance test : IR Constant ) |
- |
0 |
|
NA |
| 19.2(Partial discharge test) |
- |
10500 |
|
10500 for 3 core
5250 for 1 core |
| 19.3(Bending test) |
- |
3150 |
|
3150 for 3 core
2100 for 1 core |
| 19.4(Dielectric power factor test) |
- |
10500 |
|
10500 for 3 core
5250 for 1 core |
| 19.4(Dielectric power factor test) |
- |
12600 |
|
12600 for 3 core
8400 for 1 core |
| 19.5(Heating cycle test) |
- |
8400 |
|
NA |
| 19.6(Impulse withstand test) |
- |
36750 |
|
36750 above 11 kV
27300 up to 11 kV |
| 19.7(High voltage test) |
- |
6300 |
|
6300 for 3 core
3150 for 1 core |
| 19.8(Flammability test) |
- |
1500 |
|
NA |
| 19.9(Oxygen Index Test) |
- |
3750 |
|
NA |
| 19.10(Flame Retardance Test on Single Cables) |
- |
7500 |
|
NA |
| 19.11(Flame Retardance Test on Bunched Cables) |
- |
10000 |
|
NA |
| 19.13(Test for Halogen Acid Gas Evolution) |
- |
5000 |
|
NA |
| 19.14(Temperature Index) |
- |
6250 |
|
Na |
|
30 Nov, 2028 |
- - |
| 153 |
IS 6595 : Part 2 (1993) |
Horizontal centrifugal pumps for clear, cOld water: Part 2 general pmUrpose (Other than agricultural and rural water supply) - Specification (Second Revision) |
Voltage: upto 440V, Power upto 110 kW, Size: 5'' |
15985 View breakup
Upto 5.5 kW : Rs. 6,000/-;
5.51 to 11 kW : Rs. 6,700/- ;
11.1 to 22 kW : Rs. 7,200/-;
22.1 to 45 kW : Rs. 8,645/-;
45.1 to 75 kW : Rs. 12,650/-;
75.1 to 110 kW : Rs. 15,985/- ;
Installation charges will be Rs. 3000/- Extra.
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Direction of Rotation) |
- |
690 |
|
Nil |
| 8.1(Design Limitations) |
- |
0 |
|
Nil |
| 9.1(General Requirements) |
- |
2530 |
|
Nil |
| 10.1(Pump test, tolerances, and verification of guarantee on Pump Performance) |
- |
9200 |
|
Nil |
| 10.4(Hydrostatic Test) |
- |
2875 |
|
Nil |
| 7.2(Direction of Rotation) |
- |
690 |
|
Nil |
| 9.2(General Requirements) |
- |
0 |
|
Nil |
| 9.3(General Requirements
Shaft) |
- |
0 |
|
Nil |
| 9.4(General Requirements) |
- |
0 |
|
Nil |
| 9.5(General Requirements) |
- |
0 |
|
Nil |
| 9.6(General Requirements) |
- |
0 |
|
Nil |
| 9.7(General Requirements) |
- |
0 |
|
Nil |
| 8.2(Design Limitations
Suction Limitations) |
- |
0 |
|
Nil |
| 8.2(Design Limitations
Suction Limitations) |
- |
0 |
|
Nil |
| 8.3(Design Limitations) |
- |
0 |
|
Nil |
| 6.1(Observation) |
- |
2530 |
|
NA |
| 14(Observation) |
- |
690 |
|
NA |
|
30 Nov, 2028 |
- - |
| 154 |
IS 7538 (1996) |
Three - Phase squirrel cage induction motors for centrifugal pumps for agricultural application - Specification (First Revision) |
Up to 110 kW 2 & 4 pole, 90 kW 6 pole, 75 kW 8 pole |
119071 View breakup
Up to 5.5kW : Rs. 10,820/- ;
5.5kW to 11kW : Rs. 12,160/- ;
11kW to 22kW : Rs. 20,126/- ;
22.1kW to 45kW : 39,300/- ;
45.1kW to 75kW : Rs. 59,950/- ;
75.1kW to 110kW : Rs. 1,19,071/- .
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 20.1( MARKING) |
- |
1000 |
|
NA |
| 11(PROVISION FOR EARTHING) |
- |
1000 |
|
NA |
| 22.3.1 b)(Measurement of stator resistance) |
- |
1200 |
|
NA |
| 24.1(No-load running of motor and reading of
' voltage) |
- |
2000 |
|
NA |
| 24.1(No-load running of motor and reading of
' current ) |
- |
2000 |
|
NA |
| 24.1(No-load running of motor and reading of
' power input ) |
- |
2000 |
|
NA |
| 24.1(No-load running of motor and reading of
' speed ) |
- |
2000 |
|
NA |
| 24.2(Reduced Voltage Running Up Test) |
- |
1500 |
|
NA |
| 24.4(Full Load Test : voltage) |
- |
10000 |
|
NA |
| 24.4(Full Load Test : Power input ) |
- |
10000 |
|
NA |
| 24.4(Full Load Test : current ) |
- |
10000 |
|
NA |
| 24.4(Full Load Test : speed) |
- |
10000 |
|
NA |
| 24.5(Test for efficiency at reduced load) |
- |
10000 |
|
NA |
| 13.1(OVERLOAD:Momentary Excess Torque) |
- |
4000 |
|
NA |
| 23.1(TEMPERATURE-RISE TEST : Test at Rated Voltage) |
- |
14000 |
|
NA |
| 23.2(TEMPERATURE-RISE TEST: Test at Reduced Voltage) |
- |
14000 |
|
NA |
| 24.3(Locked Rotor Test:The readings of the input
current) |
- |
4500 |
|
NA |
| 24.3(Locked Rotor Test:The readings of the input
power) |
- |
4500 |
|
NA |
| 24.3(Locked Rotor Test:The readings of the breakaway rotor torque) |
- |
4500 |
|
NA |
| 25(HIGH-VOLTAGE TEST) |
- |
800 |
|
NA |
| 26(INSULATION-RESISTANCE TEST) |
- |
800 |
|
NA |
| 15(LIMITS OF VIBRATION SEVERITY) |
- |
6000 |
|
NA |
| 9(DIMENSIONS- H : Nominal ) |
- |
5000 |
|
NA |
| 9(DIMENSIONS- H : Deviation ) |
- |
5000 |
|
NA |
| 9(DIMENSIONS- A) |
- |
5000 |
|
NA |
| 9(DIMENSIONS- B) |
- |
5000 |
|
NA |
| 9(DIMENSIONS- C) |
- |
5000 |
|
NA |
| 9(DIMENSIONS- K+ : Nominal ) |
- |
5000 |
|
NA |
| 9(DIMENSIONS- K+ : Tolerance ) |
- |
5000 |
|
NA |
| 9(DIMENSIONS- Bolt or Screw) |
- |
5000 |
|
NA |
| 9(DIMENSIONS- M) |
- |
5000 |
|
NA |
| 9(DIMENSIONS- N) |
- |
5000 |
|
NA |
| 9(DIMENSIONS- P) |
- |
5000 |
|
NA |
| 9(DIMENSIONS- S) |
- |
5000 |
|
NA |
| 9(DIMENSIONS- T) |
- |
5000 |
|
NA |
| 9(DIMENSIONS- LA) |
- |
5000 |
|
NA |
| 9(DIMENSIONS- Depth of tapped Hole) |
- |
5000 |
|
NA |
| 27(OVERSPEED TEST) |
- |
4000 |
|
NA |
| 19.1.1(TERMINAL
MARKINGS) |
- |
1000 |
|
NA |
| 5(ENCLOSURES) |
- |
38271 |
|
NA |
|
30 Nov, 2028 |
- - |
| 155 |
IS 2993 (1998) |
A.C. motor capacitors (Second Revision) |
Up to 100 µF |
478760 View breakup
Type Tests : for Class A : Rs. 4,78,760/-, for Class B : Rs. 2,28,760/-, for Class C : Rs. 1,78,760/-, for Class D : Rs. 1,28,760/-, Routine Test for one capacitor: Rs. 11,177/-.
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.9(Capacitance measurement) |
- |
3000 |
|
RS. |
| 2.1(Check of dimensions) |
- |
720 |
|
RS. |
| 2.14(Damping heat test) |
- |
12000 |
|
RS. |
| 2.16.3(Destruction test : Test procedure) |
- |
30000 |
|
RS. |
| 2.13(Endurance test) |
- |
380000 |
|
30,000/- for Class D, 80,000/- for Class C, 1,30,000/- for Class B, 3,80,000/- for Class A |
| 2.5(Tangent of loss angle) |
- |
3000 |
|
RS. |
| 2.12(Sealing Test) |
- |
1800 |
|
RS. |
| 2.15(Self-healing test (if applicable)) |
- |
3000 |
|
RS. |
| 2.6(Visual Examination) |
- |
720 |
|
RS. |
| 5.1(Check marking) |
- |
720 |
|
RS. |
| 2.7(Voltage test between terminals) |
- |
1200 |
|
RS. |
| 2.8(Voltage test between terminals and case) |
- |
1200 |
|
RS. |
| 2.11.1.1(Tensile) |
- |
1960 |
|
RS. |
| 2.11.1.2(Bending (half cf the terminations)) |
- |
1960 |
|
RS. |
| 2.11 .1.3(Torsion (other half of the terminations)) |
- |
1960 |
|
RS. |
| 2.11.1.4(Torque (screw terminals)) |
- |
1960 |
|
RS. |
| 2.11.3(Vibration) |
- |
25880 |
|
RS. |
| 2.11.2(Soldering) |
- |
2150 |
|
RS. |
|
30 Nov, 2028 |
- - |
| 156 |
IS 8309 (1993) |
Compression type tubular terminal ends for aluminium conductors of insulated cables - Specification (First Revision) |
- |
3740 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Finish, IS 8309) |
- |
170 |
|
Complete test charges - 3740/- |
| 5(Dimensions, IS 8309) |
- |
300 |
|
Complete test charges - 3740/- |
| 8.2(Flattening Test, IS 8309) |
- |
630 |
|
Complete test charges - 3740/- |
| 8.3(Electrical Conductivity Test, IS 8309) |
- |
340 |
|
Complete test charges - 3740/- |
|
30 Nov, 2028 |
- 0.0 |
| 157 |
IS 398 : Part 5 (1992) |
Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) |
- |
178960 View breakup
Rs. 1,59,880/- [560 to 690 sq. mm.] & Rs. 1,78,960/- [520 sq. mm.]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 (elec)(Freedom from
defects) |
- |
125 |
|
159880/-
560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.3 Table-1 (mech)(Diameter-Aluminium wires) |
- |
125 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.3 Table-2 (mech)(Diameter-Galvanized Steel wires) |
- |
125 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.4 Table-4 (mech)(Lay Ratio- Aluminium Wire Outermost Layer) |
- |
250 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.4 Table-4 (mech)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
250 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.4 Table-4 (mech)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors eith 3 Aluminium Wire Layers) |
- |
250 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.4 Table-4 (mech)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
250 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.5.1 Table 3 (elec)(Breaking Load on Complete conductor) |
- |
360 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.5.2 Table 1 (mech)(Breaking Load of Aluminium Wires Before Stranding) |
- |
360 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.5.2 Table 1 (mech)(Breaking Load of Aluminium Wires After Stranding) |
- |
360 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.5.2 Table 2 (mech)(Breaking Load of Steel Wires After Stranding) |
- |
360 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.6.1 (mech)(Ductility by Torsion Test before stranding) |
- |
460 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.6.1 (mech)(Ductility by Torsion Test after stranding) |
- |
460 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.6.2 (mech)(Ductility by Elongation Test before stranding) |
- |
360 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.6.2 (mech)(Ductility by Elongation Test after stranding) |
- |
360 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.7.1 (mech)(Wrapping Test Aluminium Wires Before Stranding) |
- |
460 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.7.1 (mech)(Wrapping Test Aluminium Wires After Stranding) |
- |
460 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.7.2 (mech)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
460 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.7.2 (mech)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
460 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.8 (elec)(Resistance test-Aluminium wire before Stranding) |
- |
520 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 14.8 (elec)(Resistance test-Aluminium wire after stranding) |
- |
520 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.9.2 (chem)(Mass of Zinc coating) |
- |
340 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.9.2 (chem)(Uniformity of Zinc coating) |
- |
340 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.10 (elec)(Surface condition test) |
- |
14490 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.11 (elec)(Corona Test) |
- |
19200 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.12 (elec)(Radio Interference Voltage Test) |
- |
42000 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 10.4 (mech)(Direction of lay) |
- |
125 |
|
159880/-
560 to 690 sq. mm.
178960/-
520 sq. mm. |
| 13.5.2 Table 2 (mech)(Breaking Load of Steel Wires Before Stranding) |
- |
360 |
|
---- |
| 13.9 (elec)(The test of galvanising) |
- |
1210 |
|
170/- per wire
1210/- for 7 wires |
| 8.2.1 (elec)(Size of complete conductor) |
- |
125 |
|
-- |
| 8.2.2 (elec)(Resistance of complete conductor) |
- |
5200 |
|
-- |
|
30 Nov, 2028 |
- - |
| 158 |
IS 398 : Part 4 (1994) |
Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
- |
73250 View breakup
Rs. 6,585/- [15 sq. mm.],
Rs. 11,105/-[22, 34, 55, 80 & 100 sq. mm.],
Rs. 25,040/-[125,148,173, 200 & 232 sq. mm],
Rs. 45,755/-[288, 346, 400 & 465 sq. mm.],
Rs. 73,250/- [525, 570, 604, 642, 695 & 767 sq. mm.]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Freedom from Defects) |
- |
125 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
| 7.1 Table-1(Dimensional measurement of wires) |
- |
125 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
| 7.2.2 Table-2, Table-4(Calculated resistance of Stranded Conductor) |
- |
520 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
| 9.3(Direction of Lay) |
- |
125 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
| 9.2 Table 3(Lay Ratio of stranded conductors) |
- |
250 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
| 12.2 Table 1(Breaking Load Test- Before Stranding) |
- |
360 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
| 12.2 Table 1(Breaking Load Test- After Stranding) |
- |
360 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
| 12.3 Table 1(Elongation Test- Before Stranding) |
- |
360 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
| 12.3 Table 1(Elongation Test- After Stranding) |
- |
360 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
| 12.4 Table 1(Resistance of Aluminium wire) |
- |
520 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
|
30 Nov, 2028 |
- - |
| 159 |
IS 398 : Part 2 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
- |
166060 View breakup
Rs. 14,605/-[10, 18, 30, 50 & 80 sq. mm], Rs. 88,990/-[100 sq. mm], Rs. 1,27,525/-[150 & 200 sq. mm], Rs. 1,46,980/- [400 & 560 sq. mm.] & Rs. 1,66,060/- [420 & 520 sq. mm.]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires Before Stranding) |
- |
125 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires Before Stranding) |
- |
125 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires After Stranding) |
- |
125 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires After Stranding) |
- |
125 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 10 (elec)(Stranding) |
- |
125 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 10 (elec)(Stranding) |
- |
125 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 10 (elec)(Stranding) |
- |
125 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 10 (mech)(Stranding) |
- |
125 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.3 Table 1 (mech)(Breaking Load of Aluminium Wires Before Stranding) |
- |
360 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.3 Table 2 (mech)(Breaking Load of Steel Wires Before Stranding) |
- |
360 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.3 Table 1 (mech)(Breaking Load of Aluminium Wires After Stranding) |
- |
360 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.3 Table 2 (mech)(Breaking Load of Steel Wires After Stranding) |
- |
360 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
460 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
460 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.4.2 (elec)(Ductility by Elongation Test before stranding) |
- |
460 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.4.2 (elec)(Ductility by Elongation Test after stranding) |
- |
460 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.5.1 (mech)(Wrapping Test Aluminium Wires Before Stranding) |
- |
460 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.5.1 (mech)(Wrapping Test Aluminium Wires After Stranding) |
- |
460 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.5.2 (mech)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
460 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.5.2 (mech)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
460 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.6 (elec)(Resistance test-Aluminium wire before Stranding) |
- |
520 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.6 (elec)(Resistance test-Aluminium wire after stranding) |
- |
520 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.7.2 (chem)(Mass of Zinc coating) |
- |
340 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.7.2 (chem)(Uniformity of Zinc coating) |
- |
340 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Outermost Layer) |
- |
250 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
250 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
250 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.8 Table-4 (mech)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
250 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.9 (elec)(Surface condition test) |
- |
14490 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.10 (elec)(Ultimate breaking load) |
- |
14490 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
| 13.11 (elec)(Stress-strain test) |
- |
48300 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
|
30 Nov, 2028 |
- - |
| 160 |
IS 398 : Part 1 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) |
- |
33780 View breakup
Rs. 14,325/- [25, 50 & 100 sq. mm] & Rs. 33,780/-[150, 240 & 300 sq. mm]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 12.2, Table-1(Measurement of diameter of individual aluminium wire) |
- |
125 |
|
Complete test charges by considering all tests
14325/-
25, 50 & 100 sq. mm
33780/-
150, 240 & 300 sq. mm |
| 12.3, Table-1(Breaking load before stranding) |
- |
360 |
|
Complete test charges by considering all tests
14325/-
25, 50 & 100 sq. mm
33780/-
150, 240 & 300 sq. mm |
| 12.3, Table-1(Breaking load after stranding) |
- |
360 |
|
Complete test charges by considering all tests
14325/-
25, 50 & 100 sq. mm
33780/-
150, 240 & 300 sq. mm |
| 12.5, Table 1(Resistance test) |
- |
520 |
|
Complete test charges by considering all tests
14325/-
25, 50 & 100 sq. mm
33780/-
150, 240 & 300 sq. mm |
| 12.6, Table 3(Measurement of lay ratio) |
- |
250 |
|
Complete test charges by considering all tests
14325/-
25, 50 & 100 sq. mm
33780/-
150, 240 & 300 sq. mm |
| 12.4(Wrapping test) |
- |
460 |
|
Complete test charges by considering all tests
14325/-
25, 50 & 100 sq. mm
33780/-
150, 240 & 300 sq. mm |
| 6(Freedom from defects) |
- |
125 |
|
Complete test charges by considering all tests
14325/-
25, 50 & 100 sq. mm
33780/-
150, 240 & 300 sq. mm |
| 9.3(Stranding) |
- |
125 |
|
Complete test charges by considering all tests
14325/-
25, 50 & 100 sq. mm
33780/-
150, 240 & 300 sq. mm |
|
30 Nov, 2028 |
- 0.0 |
| 161 |
IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
DISTRIBUTON TRANSFORMER |
203805 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
800 |
|
Test charges for subsequent tap Rs. 400 |
| 14.1(MOUNTING ARRANGEMENT) |
- |
800 |
|
- |
| 14.2(MOUNTING ARRANGEMENT) |
- |
800 |
|
- |
| 14.3(MOUNTING ARRANGEMENT) |
- |
800 |
|
- |
| 14.4(MOUNTING ARRANGEMENT) |
- |
800 |
|
- |
| 21.2 a)(Measurement of winding resistance ) |
- |
600 |
|
Test charges for subsequent tap Rs. 300 |
| 21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
3750 |
|
Test charges for subsequent tap Rs. 2500 |
| 21.2 d)(Measurement of no-load loss and current) |
- |
2500 |
|
Test charges for subsequent tap Rs. 1250 |
| 21.2 e)(Measurement of insulation resistance) |
- |
500 |
|
Test charges for subsequent tap Rs. 500 |
| 21.3(b)(Temperature-rise test) |
- |
15000 |
|
- |
| 21.2 f)(Induced over-voltage withstand test) |
- |
1000 |
|
Test charges for subsequent tap Rs. 1000 |
| 21.2 g)( Separate-source voltage withstand test) |
- |
1000 |
|
Test charges for subsequent tap Rs. 1000 |
| 21.3(c)(Short-circuit withstand test) |
- |
59800 |
|
Test charges may vary as per KVA rating. Given charges upto 250 KVA, 11 KV. |
| 21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
6000 |
|
- |
| 21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
6000 |
|
- |
| 21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
6000 |
|
- |
| 21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
6000 |
|
- |
| 21.5.2.3( Oil leakage test (routine test)) |
- |
5000 |
|
- |
| 21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
6000 |
|
- |
| 21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
6000 |
|
- |
| 21.5.3.3(Oil leakage test (routine test)) |
- |
5000 |
|
- |
| 15.5(Total Dry Film Paint Thickness) |
- |
3000 |
|
- |
| 21.4 e(BDV and moisture content of oil in the transformer) |
- |
3000 |
|
- |
| 21.4 d(Paint adhesion tests) |
- |
3000 |
|
- |
| 6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
5000 |
|
- |
| 21.4 c(No load current at 112.5 percent voltage.) |
- |
1600 |
|
Test charges for subsequent tap Rs. 800 |
| 11(Minimum clearance in Air) |
- |
1000 |
|
- |
| 16(Conservator for Non-sealed type Transformers) |
- |
800 |
|
- |
| 20(Fittings) |
- |
800 |
|
- |
| 21.3(a )(Lightning impulse test) |
- |
33000 |
|
Charges given for above 250 KVA to 500 KVA. so test charges vary by rating of transformer |
| 21.4 b(Short-circuit withstand test IS 2026 (Part 5) (above 200 kVA)) |
- |
78200 |
|
- |
| 21.4 a)( Determination of sound levels) |
- |
2275 |
|
Additional tap - 2275 |
| 6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
| 7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
| 8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
| 6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
| 7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
| 8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
| 21.5.1.3(Oil leakage test upto 200 KVA) |
- |
5000 |
|
- |
|
30 Nov, 2028 |
- - |
| 162 |
IS 14286 (2010) |
Crystalline silicon terrestrial photovoltaic (PV) modules - Design qualification and type approval (First Revision) |
- |
963359 View breakup
Rs. 9,63,359/- (For complete testing)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.1(Visual inspection) |
- |
9217 |
|
- |
| 10.2(Maximum power determination) |
- |
28173 |
|
- |
| 10.3(Insulation test) |
- |
4488 |
|
- |
| 4(Marking) |
- |
0 |
|
- |
| 10.4(Measurement of temperature coefficients) |
- |
32669 |
|
- |
| 10.5(Measurement of NOCT) |
- |
52133 |
|
- |
| 10.6(Performance at STC and NOCT) |
- |
28173 |
|
- |
| 10.7(Performance at low irradiance) |
- |
5245 |
|
- |
| 10.8(Outdoor exposure test) |
- |
66472 |
|
- |
| 10.9(Hot-spot endurance test) |
- |
61005 |
|
- |
| 10.10(UV preconditioning) |
- |
47327 |
|
- |
| 10.11(Thermal cycling test) |
- |
272058 |
|
- |
| 10.12(Humidity freeze test) |
- |
96055 |
|
- |
| 10.13(Damp heat test) |
- |
107667 |
|
- |
| 10.14(Robustness of termination test) |
- |
19176 |
|
- |
| 10.15(Wet leakage current test) |
- |
9507 |
|
- |
| 10.16(Mechanical load test) |
- |
38498 |
|
- |
| 10.17(Hail test) |
- |
42422 |
|
- |
| 10.18(Bypass diode thermal' test) |
- |
43074 |
|
- |
|
30 Nov, 2028 |
- Included w.e.f. 05.12.2023 |
| 163 |
IS 648 (2022) |
Cold rolled non-oriented electrical steel sheet and strip - Fully processed type - Specification Sixth Revision |
All Grades as Per Table-1 |
36535 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. No. 6.3.2(Adherence test for CRNO strips) |
- |
575 |
|
Adherence for CRNO Strips |
| Cl. No. 7.1.1.1 & Table-1(AC Magnetization for CRNO Strips) |
- |
4695 |
|
A.C. Magnetization for CRNO Strips (At 2500, 5000 & 10000 AT/m) |
| Cl. No. 7.1.2.1 , 7.1.2.2 & Table-1(Specific Core Loss Measurement with Annealing & with Ageing for CRNO strips) |
- |
11290 |
|
Specific Core Loss (At 1.0 T & 1.5 T) With Annealing & With Ageing |
| Cl. No. 7.1.2.1 & Table-1(Specific Core Loss Measurement without Annealing & with Ageing for CRNO strips) |
- |
9620 |
|
Specific Core Loss (At 1.0 T & 1.5 T) Without Annealing & With Ageing |
| Cl. No. 7.1.2.1 & Table-1(Specific Core Loss Measurement without Annealing & without Ageing for CRNO strips) |
- |
2030 |
|
Specific Core Loss (At 1.0 T & 1.5 T) Without Annealing & Without Ageing |
| Cl. No. 7.1.2.3 & Table-1(Anisotropy of Losses for CRNO Strips) |
- |
2185 |
|
Anisotropy of Losses for CRNO strips |
| Cl. No. 7.2.5(Surface Insulation Resistivity for CRNO Strips) |
- |
2230 |
|
Surface Insulation Resistivity for CRNO Strips |
| Cl. No. 7.2.6(Thermal Effect on Coating for CRNO Strips) |
- |
11385 |
|
Thermal Effect on Coating for CRNO Strips |
| Cl. No. 9.1 &Table-1(Stacking Factor for CRNO Strips) |
- |
575 |
|
Stacking Factor for CRNO Strips |
| Cl. No. 9.2 & Table-1(Ductility (Bend test) for CRNO Strips) |
- |
575 |
|
Ductility (Bend Test) for CRNO Strips |
| Cl. No. 7.2.7(Resistance to Solvent for CRNO Strips) |
- |
2450 |
|
Resistance to Solvents for CRNO Strips |
| Cl. No. 8.1(Thickness for CRNO Strips) |
- |
575 |
|
Lamination Thickness for CRNO Strips |
| Cl. No. 6.3.2(Adherence test for CRNO strips) |
- |
575 |
|
Adherence for CRNO Strips |
| Cl. No. 7.1.1.1 & Table-1(AC Magnetization for CRNO Strips) |
- |
4695 |
|
A.C. Magnetization for CRNO Strips (At 2500, 5000 & 10000 AT/m) |
| Cl. No. 7.1.2.1 , 7.1.2.2 & Table-1(Specific Core Loss Measurement with Annealing & with Ageing for CRNO strips) |
- |
11290 |
|
Specific Core Loss (At 1.0 T & 1.5 T) With Annealing & With Ageing |
| Cl. No. 7.1.2.1 & Table-1(Specific Core Loss Measurement without Annealing & with Ageing for CRNO strips) |
- |
9620 |
|
Specific Core Loss (At 1.0 T & 1.5 T) Without Annealing & With Ageing |
| Cl. No. 7.1.2.1 & Table-1(Specific Core Loss Measurement without Annealing & without Ageing for CRNO strips) |
- |
2030 |
|
Specific Core Loss (At 1.0 T & 1.5 T) Without Annealing & Without Ageing |
| Cl. No. 7.1.2.3 & Table-1(Anisotropy of Losses for CRNO Strips) |
- |
2185 |
|
Anisotropy of Losses for CRNO strips |
| Cl. No. 7.2.5(Surface Insulation Resistivity for CRNO Strips) |
- |
2230 |
|
Surface Insulation Resistivity for CRNO Strips |
| Cl. No. 7.2.6(Thermal Effect on Coating for CRNO Strips) |
- |
11385 |
|
Thermal Effect on Coating for CRNO Strips |
| Cl. No. 9.1 &Table-1(Stacking Factor for CRNO Strips) |
- |
575 |
|
Stacking Factor for CRNO Strips |
| Cl. No. 9.2 & Table-1(Ductility (Bend test) for CRNO Strips) |
- |
575 |
|
Ductility for CRNO Strips |
| Cl. No. 7.2.7(Resistance to Solvent for CRNO Strips) |
- |
2450 |
|
Resistance to Solvents for CRNO Strips |
| Cl. No. 8.1(Thickness for CRNO Strips) |
- |
575 |
|
Lamination Thickness for CRNO Strips |
| Cl. No. 6.3.2(Adherence test for CRNO strips) |
- |
575 |
|
Adherence for CRNO Strips |
| Cl. No. 7.1.1.1 & Table-1(AC Magnetization for CRNO Strips) |
- |
4695 |
|
A.C. Magnetization for CRNO Strips (At 2500, 5000 & 10000 AT/m) |
| Cl. No. 7.1.2.1 , 7.1.2.2 & Table-1(Specific Core Loss Measurement with Annealing & with Ageing for CRNO strips) |
- |
11290 |
|
Specific Core Loss (At 1.0 T & 1.5 T) With Annealing & With Ageing |
| Cl. No. 7.1.2.1 & Table-1(Specific Core Loss Measurement without Annealing & with Ageing for CRNO strips) |
- |
9620 |
|
Specific Core Loss (At 1.0 T & 1.5 T) Without Annealing & With Ageing |
| Cl. No. 7.1.2.1 & Table-1(Specific Core Loss Measurement without Annealing & without Ageing for CRNO strips) |
- |
2030 |
|
Specific Core Loss (At 1.0 T & 1.5 T) Without Annealing & Without Ageing |
| Cl. No. 7.1.2.3 & Table-1(Anisotropy of Losses for CRNO Strips) |
- |
2185 |
|
Anisotropy of Losses for CRNO strips |
| Cl. No. 7.2.5(Surface Insulation Resistivity for CRNO Strips) |
- |
2230 |
|
Surface Insulation Resistivity for CRNO Strips |
| Cl. No. 7.2.6(Thermal Effect on Coating for CRNO Strips) |
- |
11385 |
|
Thermal Effect on Coating for CRNO Strips |
| Cl. No. 9.1 &Table-1(Stacking Factor for CRNO Strips) |
- |
575 |
|
Stacking Factor for CRNO Strips |
| Cl. No. 9.2 & Table-1(Ductility (Bend test) for CRNO Strips) |
- |
575 |
|
Ductility for CRNO Strips |
| Cl. No. 7.2.7(Resistance to Solvent for CRNO Strips) |
- |
2450 |
|
Resistance to Solvents for CRNO Strips |
| Cl. No. 8.1(Thickness for CRNO Strips) |
- |
575 |
|
Lamination Thickness for CRNO Strips |
|
30 Nov, 2028 |
- Included w.e.f. 05.12.2023. Exclusion: Cl. No. 8.3 (Length Tolerance for CRNO strips), Cl. No. 8.5 (Tolerance on shape for CRNO strips), Cl. No. 8.6 (Flatness (Wavefactor) for CRNO strips), Cl. No. 8.2 (Width Tolerance for CRNO strips), Cl. No. 8.4 (Size Tolerance on size for CRNO strips) |