121 |
IS 10322 : Part 5 : Sec 8 (2013) |
Luminaires: Part 5 particular requirements: Sec 8 emergency lighting |
- |
-
|
68250 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Marking) |
- |
500 |
|
NA |
7.0(Construction) |
- |
27880 |
|
Above test charges included charges of CONSTRUCTION, TERMINALS, EXTERNAL & INTERNAL WIRING: 2000, charges of Vibration test : 25880.
Total Test Charges: (2000+25880)= 27880. |
8.0(Creepage Distance and Clearances) |
- |
500 |
|
NA |
9.0(Provision for earthing) |
- |
500 |
|
NA |
10.0(Terminals) |
- |
0 |
|
NA |
11.0(External & Internal Wiring) |
- |
0 |
|
NA |
12.0(Protection against electric shock) |
- |
500 |
|
NA |
13.0(Endurance Tests and Thermal Tests) |
- |
17600 |
|
Above test charges included of charges ENDURANCE TEST: 11600, charges of thermal normal test: 3000, thermal abnormal charges: 3000.
Total test charges: (11600+3000+3000)= 17600. |
14.0(Resistance to Dust & Moisture) |
- |
13349 |
|
Above test charges included charges of Resistance to dust [IP 54/IP65/IP66]: 7849, charges of RESISTANCE TO MOISTURE: 5500.
Total test charges: (7849+5500)= 13349. |
15.0(Insulation Resistance and Electric Strength) |
- |
1000 |
|
NA |
16.0(Resistance to Heat , fire and tracking) |
- |
12070 |
|
Above test charges included charges of RESISTANCE TO HEAT: 1500, [NEEDLE FLAME TEST] charges: 3500, [GLOW WIRE TEST]: 5000, RESISTANCE TO TRACKING: 2070.
Total test charges: (1500+3500+5000+2070)=12070 |
17.0(Functional Safety) |
- |
30000 |
|
NA |
18.0(Changeover Operation) |
- |
6000 |
|
NA |
19.0(High Temperature Operation) |
- |
6000 |
|
NA |
20.0(BATTERY CHARGERS FOR SELFCONTAINED EMERGENCY LUMINAIRES) |
- |
6000 |
|
NA |
21.0(TEST DEVICES FOR EMERGENCY OPERATION) |
- |
3000 |
|
NA |
22.0(REST MODE AND INIHIBITION MODE FACILITIES) |
- |
3000 |
|
NA |
|
Complete
|
|
30 Nov, 2025 |
- - |
122 |
IS/IEC 60079 : Part 1 (2014) |
Explosive Atmospheres - Part 1 : Equipment Protection by Flameproof Enclosures "d" |
- |
-
|
161600 View breakup
Rs. 13,500/- (for routine test only) ;
Rs.1,61,600/-(for product wise applicable tests)
Documentation charges will be Rs. 6,000/- Extra.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
10.2(Openings for breathing or draining) |
- |
6000 |
|
Documentation charges |
10.3(Composition limits) |
- |
0 |
|
charges included documentation charges |
10.4(Dimensions) |
- |
0 |
|
charges included documentation charges |
10.5(Elements with measurable paths) |
- |
0 |
|
Nil |
10.6(Elements with non-measurable paths) |
- |
0 |
|
Nil |
10.7.1(Removable devices) |
- |
0 |
|
Nil |
10.7.2(Mounting arrangements of the elements) |
- |
0 |
|
Nil |
10.7.2(Mounting arrangements of the elements) |
- |
0 |
|
Nil |
10.7.2(Mounting arrangements of the elements) |
- |
0 |
|
Nil |
10.8(Mechanical strength) |
- |
2000 |
|
Nil |
10.9(Breathing devices and draining devices when used as Ex components) |
- |
0 |
|
refer sub clause |
10.9.1(General) |
- |
0 |
|
Nil |
10.9.2(Mounting arrangements of the elements and components) |
- |
0 |
|
Nil |
10.9.2(Mounting arrangements of the elements and components) |
- |
0 |
|
Nil |
10.9.3.3(Test for non-transmission of an internal ignition - Test procedure as per Cl 10.9.3.3.2) |
- |
12200 |
|
Nil |
10.9.3.4(Test of the ability of the breathing and draining device to withstand pressure -Test procedure as per Cl 10.9.3.4.1) |
- |
4500 |
|
Nil |
10.9.4(Ex component certificate) |
- |
0 |
|
charges included documentation charges |
6(Sealed joints) |
- |
3200 |
|
Nil |
6.1(Cemented joints) |
- |
0 |
|
refer cl. no. 6 charges |
6.1.1(General) |
- |
0 |
|
refer cl. no. 6 charges |
6.1.2(Mechanical strength) |
- |
0 |
|
refer cl. no. 6 charges |
6.1.2(Mechanical strength) |
- |
0 |
|
refer cl. no. 6 charges |
6.1.2(Mechanical strength) |
- |
0 |
|
refer cl. no. 6 charges |
6.1.3(Width of cemented joints) |
- |
0 |
|
refer cl. no. 6 charges |
6.2(Fused glass joints) |
- |
0 |
|
refer cl. no. 6 charges |
6.2.2(Width of fused glass joints) |
- |
0 |
|
refer cl. no. 6 charges |
15.2.2(Determination of explosion pressure (reference pressure)) |
- |
10800 |
|
Nil |
13.1(Entries for flameproof enclosures) |
- |
3200 |
|
Nil |
13.1(Entries for flameproof enclosures) |
- |
0 |
|
refer cl. no. 13.1 |
13.2(Threaded holes) |
- |
0 |
|
refer cl. no. 13.1 |
13.2(Threaded holes) |
- |
0 |
|
refer cl. no. 13.1 |
13.3(Non-threaded holes (for Group I only)) |
- |
0 |
|
refer cl. no. 13.1 |
13.4(Cable glands) |
- |
0 |
|
refer cl. no. 13.1 |
13.4(Cable glands) |
- |
0 |
|
refer cl. no. 13.1 |
13.5.1(Conduit sealing devices) |
- |
0 |
|
refer cl. no. 13.1 |
13.5.1(Conduit sealing devices) |
- |
0 |
|
refer cl. no. 13.1 |
13.5.2(Conduit sealing devices) |
- |
0 |
|
refer cl. no. 13.1 |
13.5.3(Conduit sealing devices) |
- |
0 |
|
refer cl. no. 13.1 |
13.5.3(Conduit sealing devices) |
- |
0 |
|
refer cl. no. 13.1 |
13.5.3(Conduit sealing devices) |
- |
0 |
|
refer cl. no. 13.1 |
13.6.1(Plugs and sockets and cable couplers) |
- |
0 |
|
refer cl. no. 13.1 |
13.6.2(Plugs and sockets and cable couplers) |
- |
0 |
|
refer cl. no. 13.1 |
13.6.3(Plugs and sockets and cable couplers) |
- |
0 |
|
refer cl. no. 13.1 |
13.6.4(Plugs and sockets and cable couplers) |
- |
0 |
|
refer cl. no. 13.1 |
13.6.5(Plugs and sockets and cable couplers) |
- |
0 |
|
refer cl. no. 13.1 |
13.7(Bushings) |
- |
0 |
|
refer cl. no. 13.1 |
13.7(Bushings) |
- |
0 |
|
refer cl. no. 13.1 |
13.8(Blanking elements) |
- |
0 |
|
refer cl. no. 13.1 |
13.8(Blanking elements) |
- |
0 |
|
refer cl. no. 13.1 |
13.8(Blanking elements) |
- |
0 |
|
refer cl. no. 13.1 |
11.1(Fasteners and openings) |
- |
2300 |
|
Nil |
11.2(Fasteners and openings) |
- |
0 |
|
refer cl. no. 11.1 |
11.3(Fasteners and openings) |
- |
0 |
|
refer cl. no. 11.1 |
11.4(Fasteners and openings) |
- |
0 |
|
refer cl. no. 11.1 |
11.5(Fasteners and openings) |
- |
0 |
|
refer cl. no. 11.1 |
11.6(Fasteners and openings) |
- |
0 |
|
refer cl. no. 11.1 |
11.7(Fasteners and openings) |
- |
0 |
|
refer cl. no. 11.1 |
11.8(Fasteners and openings) |
- |
0 |
|
refer cl. no. 11.1 |
11.9(Fasteners and openings) |
- |
0 |
|
refer cl. no. 11.1 |
5(Flameproof joints) |
- |
3200 |
|
Nil |
5.1(General requirements) |
- |
0 |
|
refer cl. no. 5 |
5.1(General requirements) |
- |
0 |
|
refer cl. no. 5 |
5.1(General requirements) |
- |
0 |
|
refer cl. no. 5 |
5.1(General requirements) |
- |
0 |
|
refer cl. no. 5 |
5.1(General requirements) |
- |
0 |
|
refer cl. no. 5 |
5.1(General requirements) |
- |
0 |
|
refer cl. no. 5 |
5.1(General requirements) |
- |
0 |
|
refer cl. no. 5 |
5.2(Non-threaded joints) |
- |
0 |
|
refer cl. no. 5 |
5.2.1(Width of joints (L)) |
- |
0 |
|
refer cl. no. 5 |
5.2.1(Width of joints (L)) |
- |
0 |
|
refer cl. no. 5 |
5.2.2(Gap (i)) |
- |
0 |
|
refer cl. no. 5 |
5.2.2(Gap (i)) |
- |
0 |
|
refer cl. no. 5 |
5.2.2(Gap (i)) |
- |
0 |
|
refer cl. no. 5 |
5.2.2(Gap (i)) |
- |
0 |
|
refer cl. no. 5 |
5.2.3(Spigot joints) |
- |
0 |
|
refer cl. no. 5 |
5.2.4(Holes in joint surfaces) |
- |
0 |
|
refer cl. no. 5 |
5.2.5(Conical joints) |
- |
0 |
|
refer cl. no. 5 |
5.2.6(Joints with partial cylindrical surfaces (not permitted for Group IIC)) |
- |
0 |
|
refer cl. no. 5 |
5.2.6(Joints with partial cylindrical surfaces (not permitted for Group IIC)) |
- |
0 |
|
refer cl. no. 5 |
5.2.7(Flanged joints for acetylene atmospheres) |
- |
0 |
|
refer cl. no. 5 |
5.2.8(Serrated joints) |
- |
0 |
|
refer cl. no. 5 |
5.2.8(Serrated joints) |
- |
0 |
|
refer cl. no. 5 |
5.2.8(Serrated joints) |
- |
0 |
|
refer cl. no. 5 |
5.2.8(Serrated joints) |
- |
0 |
|
refer cl. no. 5 |
5.2.9(Multi-step joints) |
- |
0 |
|
refer cl. no. 5 |
5.2.9(Multi-step joints) |
- |
0 |
|
refer cl. no. 5 |
5.2.9(Multi-step joints) |
- |
0 |
|
refer cl. no. 5 |
5.3(Threaded joints) |
- |
0 |
|
refer cl. no. 5 |
5.4(Gaskets (including O-rings)) |
- |
0 |
|
refer cl. no. 5 |
5.4(Gaskets (including O-rings)) |
- |
0 |
|
refer cl. no. 5 |
5.5(Equipment using capillaries) |
- |
0 |
|
refer cl. no. 5 |
9(Light-transmitting parts) |
- |
0 |
|
Included in documentation charges |
20(Marking) |
- |
2000 |
|
Nil |
20.1(General) |
- |
0 |
|
refer cl. no. 20 |
20.2(Caution and warning markings) |
- |
0 |
|
refer cl. no. 20 |
20.3(Informative markings) |
- |
0 |
|
refer cl. no. 20 |
12.1(Materials) |
- |
0 |
|
Included in documentation charges |
12.2(Materials) |
- |
0 |
|
Included in documentation charges |
12.3(Materials) |
- |
0 |
|
Included in documentation charges |
12.4(Materials) |
- |
0 |
|
Included in documentation charges |
12.5(Materials) |
- |
0 |
|
Included in documentation charges |
12.6(Materials) |
- |
0 |
|
Included in documentation charges |
12.7(Materials) |
- |
0 |
|
Included in documentation charges |
12.8(Materials) |
- |
0 |
|
Included in documentation charges |
7(Operating rods) |
- |
3200 |
|
Nil |
7(Operating rods) |
- |
0 |
|
refer cl. no. 7 |
8.1.1(Joints of shafts) |
- |
3200 |
|
Nil |
8.1.1(Joints of shafts) |
- |
0 |
|
refer cl. no. 8.1.1 |
8.1.2(Cylindrical joints) |
- |
0 |
|
refer cl. no. 8.1.1 |
8.1.3(Labyrinth joints) |
- |
0 |
|
refer cl. no. 8.1.1 |
8.1.4(Joints with floating glands) |
- |
0 |
|
refer cl. no. 8.1.1 |
8.2.1(Sleeve bearings) |
- |
0 |
|
refer cl. no. 8.1.1 |
8.2.1(Sleeve bearings) |
- |
0 |
|
refer cl. no. 8.1.1 |
8.2.2(Rolling-element bearings) |
- |
0 |
|
refer cl. no. 8.1.1 |
19.4(Test of erosion by flame) |
- |
21600 |
|
Nil |
15.2.3.2(Overpressure test – First method (static)) |
- |
15300 |
|
Nil |
14(Voltage, Current, Power, Torque, Speed, Temperature) |
- |
68900 |
|
IP test will be charged separately. |
|
Complete
|
|
30 Nov, 2025 |
- - |
123 |
IS 16270 (2014) |
Secondary cells and batteries for solar photovoltaic application - General requirements and methods of test |
Cell and Battery capacity up to 800 Ah. (Lead acid & N |
-
|
625800 View breakup
Lead acid cell/battery (Vented/monobloc/VRLA) & NI-Cd Cell/ Battery rating up to 800Ah : Rs. 6,25,800/- .
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Condition of use) |
- |
0 |
|
--- |
5.1(Mechanical Endurance) |
- |
0 |
|
--- |
5.2(Charge efficiency) |
- |
0 |
|
--- |
5.3(Deep discharge protection) |
- |
0 |
|
--- |
5.4(Marking) |
- |
0 |
|
--- |
5.5(Dafety) |
- |
0 |
|
--- |
5.6(Documentation) |
- |
0 |
|
--- |
6(Finctional Characteristics) |
- |
0 |
|
--- |
7(General test conditions) |
- |
0 |
|
--- |
8.1(Capacity test) |
- |
6550 |
|
--- |
8.2(Endurance test) |
- |
207950 |
|
--- |
8.3(Charge retention test) |
- |
28750 |
|
--- |
8.4(Cycle endurance in Photovoltaic application) |
- |
315850 |
|
--- |
8.5(Sulphation Test) |
- |
32550 |
|
--- |
8.6(Water loss test) |
- |
31800 |
|
--- |
8.7(Non spillability) |
- |
2350 |
|
--- |
|
Complete
|
|
30 Nov, 2025 |
- - |
124 |
IS/IEC 60898 : PART 1 (2015) |
Electrical accessories - Circuit - Breakers for overcurrent protection for household and similar installations: Part 1 circuit - Breakers for a.c. operation (First Revision) |
- |
-
|
328746 View breakup
Rs. 3,28,746/- (For complete testing)
One rating: Seq A1 Rs. 9,464/- ; Seq A2 Rs. 1,725/- ; Seq B Rs. 1,05,840/- ; Seq C1 Rs. 53,820/- ; Seq C2 Rs. 21,390/- ; Seq D0 Rs. 7,188/- ; Seq D Rs. 62,848/- ; Seq E1 Rs. 33,409/- ; Seq E2 Rs. 33,409/- ; Seq E3 Rs. 33409/-
Routine tests: Rs. 4,428/-.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.2(Classification, IS 60898-1) |
- |
500 |
|
- |
4.4(Classification, IS 60898-1) |
- |
500 |
|
- |
4.3(Classification, IS 60898-1) |
- |
500 |
|
- |
4.5(Classification, IS 60898-1) |
- |
500 |
|
- |
4.5.1(Classification, IS 60898-1) |
- |
500 |
|
- |
4.5.2(Classification, IS 60898-1) |
- |
500 |
|
- |
4.6(Classification, IS 60898-1) |
- |
500 |
|
- |
4.7(Classification, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
8.1.1(General, IS 60898-1) |
- |
500 |
|
- |
8.1.2(Mechanism, IS 60898-1) |
- |
500 |
|
- |
8.1.3(Clearances and creepage distances, IS 60898-1) |
- |
650 |
|
- |
8.1.4.1(Reliability of Screws current carrying parts and connections IS 60898-1) |
- |
500 |
|
- |
8.1.4.2(Reliability of Screws current carrying parts and connections IS 60898-1) |
- |
500 |
|
- |
8.1.4.3(Reliability of Screws current carrying parts and connections IS 60898-1) |
- |
500 |
|
- |
8.1.4.4(Reliability of Screws current carrying parts and connections IS 60898-1) |
- |
500 |
|
- |
8.1.5.1(Reliability of terminals for external conductors, IS 60898-1) |
- |
500 |
|
- |
8.1.5.2(Reliability of terminals for external conductors, IS 60898-1) |
- |
500 |
|
- |
8.1.5.3(Reliability of terminals for external conductors, IS 60898-1) |
- |
500 |
|
- |
8.1.5.4(Reliability of terminals for external conductors, IS 60898-1) |
- |
500 |
|
- |
8.1.5.5(Reliability of terminals for external conductors, IS 60898-1) |
- |
500 |
|
- |
8.1.5.6(Reliability of terminals for external conductors, IS 60898-1) |
- |
500 |
|
- |
8.1.5.7(Reliability of terminals for external conductors, IS 60898-1) |
- |
500 |
|
- |
8.1.5.8(Reliability of terminals for external conductors, IS 60898-1) |
- |
500 |
|
- |
8.1.5.9(Reliability of terminals for external conductors, IS 60898-1) |
- |
500 |
|
- |
8.1.5.10(Reliability of terminals for external conductors, IS 60898-1) |
- |
500 |
|
- |
8.1.5.11(Reliability of terminals for external conductors, IS 60898-1) |
- |
500 |
|
- |
8.1.5.12(Reliability of terminals for external conductors, IS 60898-1) |
- |
500 |
|
- |
8.2(Protection against Electric Shock, IS 60898-1) |
- |
500 |
|
- |
8.3.2(Dielectric strength at power frequency, IS 60898-1) |
- |
500 |
|
- |
8.3.3(Isolating capability, IS 60898-1) |
- |
500 |
|
- |
8.3.4(Dielectric strength at rated impulse withstand voltage ( Uimp), IS 60898-1) |
- |
500 |
|
- |
8.4(Temperature-rise, IS 60898-1) |
- |
3680 |
|
- |
8.5(Uninterrupted duty, IS 60898-1) |
- |
500 |
|
- |
8.6(Automatic operation, IS 60898-1) |
- |
500 |
|
- |
8.7(Mechanical and electrical endurance, IS 60898-1) |
- |
12305 |
|
- |
8.9(Resistance to mechanical shock and impact, IS 60898-1) |
- |
4370 |
|
- |
8.1(Resistance to heat, IS 60898-1) |
- |
1725 |
|
- |
8.11(Resistance to abnormal heat and to fire, IS 60898-1) |
- |
3220 |
|
- |
8.12(Resistance to rusting, IS 60898-1) |
- |
1392 |
|
- |
8.13(Power loss, IS 60898-1) |
- |
500 |
|
- |
9.3(Test of indelibility of marking, IS 60898-1) |
- |
500 |
|
- |
9.4(Test of reliability of screws, current-carrying parts and connections, IS 60898-1) |
- |
500 |
|
- |
9.5.1(Tests of reliability of screw-type terminals for external copper conductors, IS 60898-1) |
- |
500 |
|
- |
9.5.2(Tests of reliability of screw-type terminals for external copper conductors, IS 60898-1) |
- |
500 |
|
- |
9.5.3(Tests of reliability of screw-type terminals for external copper conductors, IS 60898-1) |
- |
500 |
|
- |
9.5.4(Tests of reliability of screw-type terminals for external copper conductors, IS 60898-1) |
- |
500 |
|
- |
9.6(Test of protection against electric shock, IS 60898-1) |
- |
500 |
|
- |
9.7.5.1(Test of protection against electric shock, IS 60898-1) |
- |
500 |
|
- |
9.7.5.2(Test of protection against electric shock, IS 60898-1) |
- |
500 |
|
- |
9.7.5.3(Test of protection against electric shock, IS 60898-1) |
- |
500 |
|
- |
9.7.5.4(Test of protection against electric shock, IS 60898-1) |
- |
500 |
|
- |
9.8(Test of temperature-rise and measurement of power loss, IS 60898-1) |
- |
3680 |
|
- |
9.8.5(Test of temperature-rise and measurement of power loss, IS 60898-1) |
- |
3680 |
|
- |
9.9(28- day test, IS 60898-1) |
- |
81650 |
|
- |
9.7.1(Test of protection against electric shock, IS 60898-1) |
- |
500 |
|
- |
9.7.2(Test of protection against electric shock, IS 60898-1) |
- |
500 |
|
- |
9.7.3(Test of protection against electric shock, IS 60898-1) |
- |
500 |
|
- |
9.10.2(Test of tripping characteristic, IS 60898-1) |
- |
13800 |
|
- |
9.10.3(Test of tripping characteristic, IS 60898-1) |
- |
13800 |
|
- |
9.10.4(Test of tripping characteristic, IS 60898-1) |
- |
13800 |
|
- |
9.10.5(Test of tripping characteristic, IS 60898-1) |
- |
13800 |
|
- |
9.11(Verification of mechanical and electrical endurance, IS 60898-1) |
- |
12305 |
|
- |
9.13.1(Mechanical Stress, IS 60898-1) |
- |
4370 |
|
- |
9.13.2.2(Mechanical Stress, IS 60898-1) |
- |
4370 |
|
- |
9.13.2.4(Mechanical Stress, IS 60898-1) |
- |
4370 |
|
- |
9.13.2.5(Mechanical Stress, IS 60898-1) |
- |
4370 |
|
- |
9.14.1(Test of resistance to heat, IS 60898-1) |
- |
1725 |
|
- |
9.14.2(Test of resistance to heat, IS 60898-1) |
- |
1725 |
|
- |
9.14.3(Test of resistance to heat, IS 60898-1) |
- |
1725 |
|
- |
9.15(Resistance to abnormal heat and to fire) |
- |
3220 |
|
- |
9.16(Test of resistance to rusting) |
- |
1392 |
|
- |
8.1.6(Non-interchangeability) |
- |
500 |
|
- |
9.13(Resistance to mechanical shock and impact) |
- |
4370 |
|
- |
I.2(Tripping tests) |
- |
3163 |
|
- |
I.3(Verification of clearances between open contacts) |
- |
1265 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
6(Marking and other product information, IS 60898-1) |
- |
500 |
|
- |
8.1.2(Mechanism, IS 60898-1) |
- |
500 |
|
- |
8.1.2(Mechanism, IS 60898-1) |
- |
500 |
|
- |
8.1.2(Mechanism, IS 60898-1) |
- |
500 |
|
- |
8.1.2(Mechanism, IS 60898-1) |
- |
500 |
|
- |
8.1.2(Mechanism, IS 60898-1) |
- |
500 |
|
- |
8.1.2(Mechanism, IS 60898-1) |
- |
500 |
|
- |
8.1.2(Mechanism, IS 60898-1) |
- |
500 |
|
- |
8.1.2(Mechanism, IS 60898-1) |
- |
500 |
|
- |
8.1.2(Mechanism, IS 60898-1) |
- |
500 |
|
- |
8.1.2(Mechanism, IS 60898-1) |
- |
500 |
|
- |
8.1.3(Clearances and creepage distances, IS 60898-1) |
- |
650 |
|
- |
8.4(Temperature-rise, IS 60898-1) |
- |
3680 |
|
- |
9.6(Test of protection against electric shock, IS 60898-1) |
- |
500 |
|
- |
9.6(Test of protection against electric shock, IS 60898-1) |
- |
500 |
|
- |
9.8(Test of temperature-rise and measurement of power loss, IS 60898-1) |
- |
3680 |
|
- |
9.8(Test of temperature-rise and measurement of power loss, IS 60898-1) |
- |
3680 |
|
- |
9.8(Test of temperature-rise and measurement of power loss, IS 60898-1) |
- |
3680 |
|
- |
9.8(Test of temperature-rise and measurement of power loss, IS 60898-1) |
- |
3680 |
|
- |
9.12(Short- Circuit tests, IS 60898-1) |
- |
59800 |
|
- |
9.12(Short- Circuit tests, IS 60898-1) |
- |
59800 |
|
- |
9.12(Short- Circuit tests, IS 60898-1) |
- |
59800 |
|
- |
9.12(Short- Circuit tests, IS 60898-1) |
- |
59800 |
|
- |
9.12(Short- Circuit tests, IS 60898-1) |
- |
59800 |
|
- |
|
Complete
|
|
30 Nov, 2025 |
- - |
125 |
IS 10322 : Part 5 : Sec 7 (2017) |
Luminaires: Part 5 particular requirements: Sec 7 lighting chains (First Revision) |
- |
-
|
56625 View breakup
Rs. 56,625/-(Except Vibration Test)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
20.6(Marking) |
- |
500 |
|
NA |
20.7(Construction) |
- |
27880 |
|
Above test charges included charges of CONSTRUCTION, TERMINALS, EXTERNAL & INTERNAL WIRING: 2000, and charges of Vibration test : 25880.
Total Test charges: (2000+25880)=27880. |
20.8(Creepage Distance and Clearances) |
- |
500 |
|
NA |
20.10(Terminals) |
- |
0 |
|
NA |
20.11(External & Internal Wiring) |
- |
0 |
|
NA |
20.12(Protection against electric shock) |
- |
500 |
|
NA |
20.13(Endurance Tests and Thermal Tests) |
- |
17600 |
|
Above test charges included charges of endurance test: 11600, charges of thermal normal test: 3000 & thermal abnormal test: 3000.
Total test charges: (11600+3000+3000)= 17600. |
20.14(Resistance to Dust & Moisture) |
- |
13349 |
|
Above test charge included charges of Resistance to dust [IP 54/IP65/IP66]: 7849, charges of RESISTANCE TO MOISTURE: 5500.
Total test charges: (7849+5500)= 13349. |
20.15(Insulation Resistance and Electric Strength) |
- |
1000 |
|
NA |
20.16(Resistance to Heat , fire and tracking) |
- |
12070 |
|
Above test charges included of charges RESISTANCE TO HEAT: 1500, charges of NEEDLE FLAME TEST: 3500, charges of GLOW WIRE TEST: 5000, charges of RESISTANCE TO TRACKING: 2070.
Total test charges: (1500+3500+5000+2070)= 12070. |
20.9(Provision for earthing) |
- |
500 |
|
NA |
|
Complete
|
|
30 Nov, 2025 |
- - |
126 |
IS 2418 : Part 1 (2018) |
Tubular fluorescent lamps for general lighting service: Part 1 safety requirements (Second Revision) |
- |
-
|
33375 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause No. 4.2 (Marking.) |
- |
900 |
|
NA |
Clause No. 4.3(Mechanical requirement for caps) |
- |
91500 |
|
a) Torsion resistance on unused lamps + 6 degree angular displacement : 1600
b) Heating treatment for 2000 hours+ 6 degree angular displacement+ Torsion after heating : 89000
c) Dimension of caps: 900 |
Clause No. 4.4(Insulation Resistance Measurement) |
- |
1000 |
|
NA |
Clause No. 4.5(Electric strength ) |
- |
1000 |
|
NA |
Clause No. 4.6(Parts which can become accidentally live) |
- |
900 |
|
NA |
Clause No. 4.7(Resistance to heat & fire) |
- |
13300 |
|
a) Resistance to heat : 12100
b) Resistance to fire: 1200 |
Clause No. 4.8(Creepage distance for caps) |
- |
900 |
|
NA |
Clause No. 4.9(Lamp cap temperature rise) |
- |
4800 |
|
NA |
Clause No. 4.10(Lamp minimum overall length) |
- |
900 |
|
NA |
|
Complete
|
|
30 Nov, 2025 |
- - |
127 |
IS 2418 : Part 2 (2018) |
Tubular fluorescent lamps for general lighting service: Part 2 performance requirements (Second Revision) |
- |
-
|
45500 View breakup
Rs. 45,500/- (Up to 2000 hrs. life) ;
Rs. 30,000/- (For additional every 1500 hrs. beyond 2000 hrs. life)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 6 of IS 2418:2:2018(MARKING) |
- |
500 |
|
NA |
Cl 7.3 of IS 2418:2:2018(Visual Examination and Checking for Marking) |
- |
500 |
|
NA |
Cl 7.4 of IS 2418:2:2018(Burning Test) |
- |
2250 |
|
NA |
Cl 7.5 of IS 2418:2:2018(Starting Characteristics) |
- |
2250 |
|
NA |
Cl 7.6 of IS 2418:2:2018(Test for Electrical Luminous and Colour
Characteristics) |
- |
7900 |
|
NA |
Cl 7.7 of IS 2418:2:2018(Chromaticity Co-ordinates
) |
- |
7900 |
|
NA |
Cl 7.8 of IS 2418:2:2018(Life and Lumen Maintenance) |
- |
40000 |
|
1. Test charges Rs.40000/- for Life and Lumen maintenance test up to 2000 hrs.
2. Test charges Rs.30000/- for additional every 1500 hrs. beyond 2000 hrs. life and lumen maintenance. |
Cl 6 of IS 2418:2:2018(MARKING) |
- |
500 |
|
NA |
Cl 5 of IS 2418:2:2018(MECHANCIAL, PHYSICAL AND STARTING
REQUIREMENTS) |
- |
700 |
|
NA |
Clause No. 7.4 & & 7.5(Burning Test & Starting Characteristics) |
- |
4500 |
|
NA |
4.2 of IS 2418 : Part 1 (2018(Marking.) |
- |
900 |
|
NA |
4.3 of IS 2418 : Part 1 (2018)(Mechanical requirement for caps) |
- |
91500 |
|
1. Test charges Rs.1600/- for torsion on unused amps + 6 deg. angular displacement.
2. Test charges Rs.89000/- for heating treatment for 2000 hrs. + 6 deg. angular displacement + torsion after heating
3. Test charges Rs.900/- for dimension of caps |
4.4 of IS 2418 : Part 1 (2018)(Insulation Resistance Measurement) |
- |
1000 |
|
NA |
4.5 of IS 2418 : Part 1 (2018)(Electric strength) |
- |
1000 |
|
NA |
4.6 of IS 2418 : Part 1 (2018)(Parts which can become accidentally live) |
- |
900 |
|
NA |
4.7 of IS 2418 : Part 1 (2018)(Resistance to heat & fire) |
- |
13300 |
|
NA |
4.8 of IS 2418 : Part 1 (2018)(Creepage distance for caps) |
- |
900 |
|
NA |
4.9 of IS 2418 : Part 1 (2018)(Lamp cap temperature rise) |
- |
4800 |
|
NA |
4.10 of IS 2418 : Part 1 (2018)(Lamp minimum overall length) |
- |
900 |
|
NA |
|
Complete
|
|
30 Nov, 2025 |
- - |
128 |
IS 12615 (2018) |
Line operated three phase AC motors (IE Code) "Efficiency classes and performance specification" (Third Revision) |
Up to 110 kW 2 & 4 pole, 90 kW 6 pole, 75 kW 8 pole |
-
|
166571 View breakup
Upto 5.5 kW Rs. 49,314/- ; 5.5 kW to 11 kW Rs. 55,303/- ; 11 kW to 22 kW Rs. 79,920/- ; 22.1 kW to 45 kW : Rs. 1,06,788/- ; 45.1 kW to 75 kW : Rs. 1,31,838/- ; 75.1 to 110 kW : Rs. 1,66,571/-. (For all tests)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
18.3(Marking) |
- |
1000 |
|
Up to 5.5 kW: Rs. 500
5.5 to 11 kW: Rs. 500
11 to 22 kW: Rs. 500
22.1 to 45 kW: Rs. 600
45.1 to 75 kW: Rs. 750
75.1 kW to 110 kW: Rs. 1000 |
16.2.1(Dimensions) |
- |
5000 |
|
Up to 5.5 kW: Rs. 715
5.5 to 11 kW: Rs. 715
11 to 22 kW: Rs. 1425
22.1 to 45 kW: Rs. 2300
45.1 to 75 kW: Rs. 3000
75.1 kW to 110 kW: Rs. 5000 |
16.1.2(Measurement of Resistance of Windings of Stator) |
- |
1200 |
|
Up to 5.5 kW: Rs. 500
5.5 to 11 kW: Rs. 500
11 to 22 kW: Rs. 500
22.1 to 45 kW: Rs. 700
45.1 to 75 kW: Rs. 900
75.1 kW to 110 kW: Rs 1200 |
16.1.3(No Load Test) |
- |
2000 |
|
Up to 5.5 kW: Rs. 500
5.5 to 11 kW: Rs. 500
11 to 22 kW: Rs. 500
22.1 to 45 kW: Rs. 900
45.1 to 75 kW: Rs. 1200
75.1 kW to 110 kW: Rs. 2000 |
16.1.5(5 Reduced Voltage Running up Test at no-load (for squirrel cage motor up to 37 kW only)) |
- |
1500 |
|
Up to 5.5 kW: Rs. 500
5.5 to 11 kW: Rs. 500
11 to 22 kW: Rs. 500
22.1 to 45 kW: Rs. 700
45.1 to 75 kW: Rs. 900
75.1 kW to 110 kW: Rs 1500 |
16.1.4(Locked Rotor Readings of Voltage, Current and Power Input at a Suitable Reduced Voltage) |
- |
4500 |
|
Up to 5.5 kW: Rs. 600
5.5 to 11 kW: Rs. 920
11 to 22 kW: Rs. 2116
22.1 to 45 kW: Rs. 2500
45.1 to 75 kW: Rs. 3000
75.1 kW to 110 kW: Rs. 4500 |
16.2.3(Full Load Test to Determine Efficiency, Power Factor and Slip) |
- |
10000 |
|
Up to 5.5 kW: Rs. 1892
5.5 to 11 kW: Rs. 2386
11 to 22 kW: Rs. 4778
22.1 to 45 kW: Rs. 6000
45.1 to 75 kW: Rs. 7500
75.1 kW to 110 kW: Rs. 10000 |
16.2.4(Temperature Rise Test) |
- |
14000 |
|
Up to 5.5 kW: Rs. 2590
5.5 to 11 kW: Rs. 4025
11 to 22 kW: Rs. 8039
22.1 to 45 kW: Rs. 8000
45.1 to 75 kW: Rs. 11000
75.1 kW to 110 kW: Rs. 14000 |
16.2.5(Momentary Overload Test) |
- |
4000 |
|
Up to 5.5 kW: Rs. 500
5.5 to 11 kW: Rs. 600
11 to 22 kW: Rs. 1380
22.1 to 45 kW: Rs. 2500
45.1 to 75 kW: Rs. 3000
75.1 kW to 110 kW: Rs. 4000 |
16.1.1(Insulation Resistance Test) |
- |
800 |
|
Up to 5.5 kW: Rs. 500
5.5 to 11 kW: Rs. 500
11 to 22 kW: Rs. 500
22.1 to 45 kW: Rs. 500
45.1 to 75 kW: Rs. 600
75.1 kW to 110 kW: Rs 800 |
16.1.6(High Voltage Test) |
- |
800 |
|
Up to 5.5 kW: Rs. 500
5.5 to 11 kW: Rs. 500
11 to 22 kW: Rs. 500
22.1 to 45 kW: Rs. 500
45.1 to 75 kW: Rs. 600
75.1 kW to 110 kW: Rs. 800 |
16.3.1( Test for Vibration Severity of Motor) |
- |
6000 |
|
Up to 5.5 kW: Rs. 1145
5.5 to 11 kW: Rs. 1145
11 to 22 kW: Rs. 2290
22.1 to 45 kW: Rs. 3500
45.1 to 75 kW: Rs. 4500
75.1 kW to 110 kW: Rs. 6000 |
9.0(Terminal Marking) |
- |
1000 |
|
Up to 5.5 kW: Rs. 500
5.5 to 11 kW: Rs. 500
11 to 22 kW: Rs. 500
22.1 to 45 kW: Rs. 600
45.1 to 75 kW: Rs. 750
75.1 kW to 110 kW: Rs. 1000 |
8.0(Earthing) |
- |
1000 |
|
Up to 5.5 kW: Rs. 500
5.5 to 11 kW: Rs. 500
11 to 22 kW: Rs. 500
22.1 to 45 kW: Rs. 600
45.1 to 75 kW: Rs. 750
75.1 kW to 110 kW: Rs. 1000 |
16.3.4(Over Speed Test) |
- |
4000 |
|
Up to 5.5 kW: Rs. 500
5.5 to 11 kW: Rs. 500
11 to 22 kW: Rs. 500
22.1 to 45 kW: Rs. 2500
45.1 to 75 kW: Rs. 3000
75.1 kW to 110 kW: Rs. 4000 |
16.3.5( Temperature Rise Test at Limiting Values of
Voltage and Frequency Variation) |
- |
56000 |
|
Up to 5.5 kW: Rs. 10360
5.5 to 11 kW: Rs. 14000
11 to 22 kW: Rs. 27960
22.1 to 45 kW: Rs. 32000
45.1 to 75 kW: Rs. 44000
75.1 kW to 110 kW: Rs. 56000 |
16.3.2( Test for Noise Levels of Motor) |
- |
10000 |
|
Up to 5.5 kW: Rs. 10000
5.5 to 11 kW: Rs. 10000
11 to 22 kW: Rs. 10000
22.1 to 45 kW: Rs. 10000
45.1 to 75 kW: Rs. 10000
75.1 kW to 110 kW: Rs. 10000 |
16.3.3( Test for Degree of Protection by Enclosure) |
- |
38271 |
|
Up to 5.5 kW: Rs. 16012
5.5 to 11 kW: Rs. 16012
11 to 22 kW: Rs. 16012
22.1 to 45 kW: Rs. 29088
45.1 to 75 kW: Rs. 32088
75.1 kW to 110 kW: Rs. 38271 |
6(Method of cooling) |
- |
500 |
|
Nil |
12.2(Pull up torque) |
- |
5000 |
|
Up to 5.5 kW: Rs. 500
5.5 to 11 kW: Rs. 500
11 to 22 kW: Rs. 920
22.1 to 45 kW: Rs. 2800
45.1 to 75 kW: Rs. 3800
75.1 kW to 110 kW: Rs. 5000 |
|
Complete
|
|
30 Nov, 2025 |
- - |
129 |
IS 16046 : Part 1 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 1 Nickel Systems ( Second Revision ) |
Cells and Batteries used in portable applications, Nic |
-
|
204460 View breakup
For nickel cadmium cells : Rs. 2,04,460/- ;
For nickel cadmium Batteries : Rs. 1,36,160/- .
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Parameter Measurement Tolerances) |
- |
500 |
|
--- |
5(General Safety Considerations) |
- |
1000 |
|
--- |
5.1(General) |
- |
0 |
|
--- |
5.2(Insulation and Wiring) |
- |
0 |
|
--- |
5.3(Venting) |
- |
0 |
|
--- |
5.4(Temperature, Voltage and Current Management) |
- |
0 |
|
--- |
5.5(Terminal Contacts) |
- |
0 |
|
--- |
5.6(Assembly of Cells into batteries) |
- |
0 |
|
--- |
5.7(Quality Plan) |
- |
0 |
|
--- |
6(Tyoe Test amd Sample Size) |
- |
500 |
|
--- |
7(Specific requirements and tests) |
- |
0 |
|
--- |
7.1(Charging procedure for test purposes) |
- |
40000 |
|
--- |
7.2(Intended Use) |
- |
80000 |
|
For cells : Rs. 75000/-
For Batteries: Rs. 40000/- |
7.3(Reasonably foreseeable misuse) |
- |
84960 |
|
For cells : Rs. 84960/-
For Batteries: Rs. 51660/- |
8.1(General) |
- |
1000 |
|
--- |
8.2(Small Cell and battery safety information) |
- |
0 |
|
--- |
9(Marking) |
- |
1000 |
|
--- |
9.1(Cell Marking) |
- |
0 |
|
--- |
9.3(Caution for ingestion of small cells and batteries) |
- |
0 |
|
--- |
9.4(Other information) |
- |
0 |
|
--- |
10(Packaging) |
- |
500 |
|
--- |
|
Complete
|
|
30 Nov, 2025 |
- - |
130 |
IS 16046 : Part 2 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 2 Lithium Systems ( Second Revision ) |
Cells and Batteries used in portable applications, Lith |
-
|
133500 View breakup
For Lithium cells : Rs. 1,33,500/- ;
For Lithium batteries : Rs. 1,32,160/- .
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Parameter Measurement Tolerances) |
- |
500 |
|
--- |
5(General Safety Considerations) |
- |
1000 |
|
--- |
5.1(General) |
- |
0 |
|
--- |
5.2(Insulation and Wiring) |
- |
0 |
|
--- |
5.3(Venting) |
- |
0 |
|
--- |
5.4(Temperature, Voltage and Current Management) |
- |
0 |
|
--- |
5.5(Terminal Contacts) |
- |
0 |
|
--- |
5.6(Assembly of Cells into batteries) |
- |
0 |
|
--- |
5.7(Quality Plan) |
- |
0 |
|
--- |
5.8(Battery Safety Components) |
- |
0 |
|
--- |
6(Type Test and Sample Size) |
- |
500 |
|
--- |
7(Specific requirements and tests) |
- |
0 |
|
--- |
7.1(Charging procedure for test purposes) |
- |
40000 |
|
--- |
7.2(Intended Use) |
- |
40000 |
|
For cell : Rs. 40000/-
For Battery : 5000/- |
7.3(Reasonably foreseeable misuse) |
- |
82660 |
|
For cell: Rs. 49000/-
For battery: Rs. 82660/- |
8(Information for safety) |
- |
1000 |
|
--- |
8.1(General) |
- |
0 |
|
--- |
8.2(Small Cell and battery safety information) |
- |
0 |
|
--- |
9(Marking) |
- |
1000 |
|
--- |
9.1(Cell Marking) |
- |
0 |
|
--- |
9.2(Battery Marking) |
- |
0 |
|
--- |
9.3(Caution for ingestion of small cells and batteries) |
- |
0 |
|
--- |
9.4(Other information) |
- |
0 |
|
--- |
10(Packaging) |
- |
500 |
|
--- |
|
Complete
|
|
30 Nov, 2025 |
- - |
131 |
IS 6162 : Part 1 (1971) |
Specification for paper - Covered aluminium conductors: Part 1 round conductors |
- |
-
|
5200 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.2(Diameter) |
- |
600 |
|
NA |
4.3(Resistance) |
- |
800 |
|
NA |
4.4(Tensile strength and Elongation) |
- |
800 |
|
NA |
6.3(Arrangement of Paper layers) |
- |
600 |
|
NA |
7(Overall diameter and increase in diameter) |
- |
1200 |
|
NA |
4.5(IS 6162 Part-1) |
- |
600 |
|
NA |
4.6(IS 6162 Part-1) |
- |
0 |
|
NA |
4.7(IS 6162 Part-1) |
- |
600 |
|
NA |
|
Complete
|
|
30 Nov, 2025 |
- - |
132 |
IS 6162 : Part 2 (1971) |
Specification for paper covered aluminium conductors: Part 2 rectangular conductors |
- |
-
|
2400 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
10.2 a(Conductor dimensions) |
- |
600 |
|
NA |
10.2 b(Arrangement of Paper layers) |
- |
600 |
|
NA |
10.2 c(Increase in dimension) |
- |
600 |
|
NA |
10.2 d(Overall dimension) |
- |
600 |
|
NA |
|
Complete
|
|
30 Nov, 2025 |
- - |
133 |
IS 7347 (1974) |
Specification for performance of small size spark ignition engines |
Up to 110 kW |
-
|
55600 View breakup
Rs. 55,600/-** for full test.
(Only rating test Rs. 9,600/-)
**Fuel charges and oil charges will be at actuals.
Note: Presence of skill person is required for dismantle/assembly of engine.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.No.10.1(a)(Marking ) |
- |
600 |
|
- |
Cl.No.10.1(b)(Marking ) |
- |
600 |
|
- |
Cl.No.10.1(c)(Marking ) |
- |
600 |
|
- |
Cl.No.9.1(h)(Reassembly ,Starting test and no load test) |
- |
600 |
|
- |
Cl.No.9.1(g)(Strip Examination) |
- |
3600 |
|
- |
Cl.No.9.1(f)(Rating test after endurance test) |
- |
6000 |
|
- |
Cl.No.9.1(e)(Endurance test) |
- |
35000 |
|
- |
Cl.No.9.1(d)(Starting test) |
- |
1450 |
|
- |
Cl. No.9.1(c)(No load and Low speed test) |
- |
2350 |
|
- |
Cl.No.9.1(a), Cl.No.9.3.1(Governing test) |
- |
2350 |
|
- |
Cl.No.9.1(a)(Rating test including Fuel consumption test) |
- |
6000 |
|
- |
|
Complete
|
|
30 Nov, 2025 |
- - |
134 |
IS 9537 : Part 1 (1980) |
Specification for conduits for electrical installations: Part 1 general requirements |
- |
-
|
29950 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Dimensions) |
- |
500 |
|
NA |
9 & 9.2("Mechanical properties
Bending test ") |
- |
6700 |
|
NA |
9.3(Compression test) |
- |
700 |
|
NA |
9.4(Impact test) |
- |
8300 |
|
NA |
9.5(Collapse test) |
- |
1700 |
|
NA |
10(Resistance to heat) |
- |
7500 |
|
NA |
11(Resistance to burning) |
- |
1000 |
|
NA |
6(Marking) |
- |
0 |
|
NA |
8(Constrution) |
- |
0 |
|
NA |
12(Electrical strength test & Insulation resistance test) |
- |
2000 |
|
NA |
|
Complete
|
|
30 Nov, 2025 |
- Exclude Cl. No. 13 Corrosion and polluting substances. |
135 |
IS 10001 (1981) |
Performance Requirements for Constant Speed Compression ignition (diesel) engines for general purposes (up to 20 kW) |
Rated power: up to 20 kW |
-
|
174000 View breakup
For performance test (above 3.5 kW) charges will be Rs. 21,700/- ;
For all tests: Rs. 99,558/-** upto 20 kW.
For all tests: Rs. 1,74,000/-** (for two cylinder engine)
** Fuel & Oil charges for all test will be at actual.
For initial Performance test Rs. 3,000/- will be charge extra.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.No.7(a)(Marking ) |
- |
1000 |
|
Nil |
Cl.No.7(b)(Marking ) |
- |
1000 |
|
Nil |
Cl.No.7(c)(Marking ) |
- |
1000 |
|
Nil |
Cl.No.7(d)(Marking ) |
- |
1000 |
|
Nil |
Cl.No.7(e)(Marking ) |
- |
1000 |
|
Nil |
Cl.No.3.1(d), Cl.No.3.5.2(Governing test) |
- |
0 |
|
Nil |
Cl.No.3.5.5(Lubricating Oil Consumption test) |
- |
8000 |
|
Nil |
Cl.No.3.1(e)(Endurance test) |
- |
85000 |
|
Nil |
Cl.No.3.1(b)(Preliminary run test) |
- |
12000 |
|
Nil |
Cl.No.3.1(a)(Dimensional Measurenment for wear.) |
- |
22000 |
|
Nil |
Cl.No.4.2(Specific Fuel Consumption) |
- |
0 |
|
Nil |
3.1 ( c)(Speed, Temperature, SFC) |
- |
21000 |
|
Nil |
3.1 (f)(Speed, Temperature, SFC) |
- |
10000 |
|
Nil |
3.1 (g)(Speed, Temperature, SFC) |
- |
8000 |
|
Nil |
3.1 (h)(Speed, Temperature, SFC) |
- |
0 |
|
Nil |
3.2(SFC) |
- |
0 |
|
Nil |
3.3(Power) |
- |
0 |
|
Nil |
3.4(Efficiency) |
- |
0 |
|
Nil |
3.5(Speed, Temperature, SFC) |
- |
0 |
|
Nil |
4.1(ml/hr) |
- |
0 |
|
Nil |
|
Complete
|
|
30 Nov, 2025 |
- - |
136 |
IS 10002 (1981) |
Specification for performance requirements for constant speed compression ignition (Diesel) engines for general purposes (Above 20 KW) |
Rated power: up to 20 kW |
-
|
174000 View breakup
For performance test charges will be Rs. 21,700/- ;
For all tests: 20.1 kW to 45 kW Rs. 99,558/-** ; for 45.1 kW to 75 kW Rs. 1,24,200/-** ; for 75.1 kW to 110 kW Rs. 1,74,000/-** .
** Fuel & Oil charges for all test will be at actual.
For initial Performance test Rs. 3,000/- will be charge extra.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.No.7(a)(Marking ) |
- |
1000 |
|
Nil |
Cl.No.7(b)(Marking ) |
- |
1000 |
|
Nil |
Cl.No.7(c)(Marking ) |
- |
1000 |
|
Nil |
Cl.No.7(d)(Marking ) |
- |
1000 |
|
Nil |
Cl.No.7(e)(Marking ) |
- |
1000 |
|
Nil |
Cl.No.3.1(f), (Governing test) |
- |
0 |
|
Nil |
Cl.No.3.5(Lubricating Oil Consumption test) |
- |
8000 |
|
Nil |
Cl.No.3.1(e)(Endurance test) |
- |
85000 |
|
Nil |
Cl.No.3.1(b)(Preliminary run test) |
- |
12000 |
|
Nil |
Cl.No.3.1(a)(Dimensional Measurenment for wear.) |
- |
22000 |
|
Nil |
Cl.No.4.2(Specific Fuel Consumption) |
- |
0 |
|
Nil |
3.1 ( c)(Speed, Temperature, SFC) |
- |
21000 |
|
Nil |
3.1 (d)(Speed, Temperature, SFC) |
- |
85000 |
|
Nil |
3.1 (g)(Speed, Temperature, SFC) |
- |
8000 |
|
Nil |
3.1 (h)(Speed, Temperature, SFC) |
- |
0 |
|
Nil |
3.2(SFC) |
- |
0 |
|
Nil |
3.3(Power) |
- |
0 |
|
Nil |
3.4(Efficiency) |
- |
0 |
|
Nil |
3.6(Speed, Temperature, SFC) |
- |
0 |
|
Nil |
4.1(Power) |
- |
0 |
|
Nil |
4.2(SFC) |
- |
0 |
|
Nil |
4.3(ml/hr) |
- |
0 |
|
Nil |
|
Complete
|
|
30 Nov, 2025 |
- - |
137 |
IS 9335 : Part 3 : Sec 1 (1984) |
Specification for cellulosic papers for electrical purposes: Part 3 specifications for individual materials: Sec 1 general purpose electrical paper |
All |
-
|
29670 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5, Table 1(Thickness) |
- |
375 |
|
375 |
5, Table 1(Substance) |
- |
1150 |
|
1150 |
5, Table 1(Apparent density) |
- |
1725 |
|
1725 |
5, Table 1(Tensile strength) |
- |
1725 |
|
1725 |
5, Table 1(elongation) |
- |
0 |
|
Including tensile strength charges |
5, Table 1(Internal tearing resistance) |
- |
1725 |
|
1725 |
5, Table 1(Moisture Content) |
- |
1150 |
|
1150 |
5, Table 1(Ash) |
- |
1725 |
|
1725 |
5, Table 1(Conductivity of Aqueous Extract) |
- |
1725 |
|
1725 |
5, Table 1(pH of Aqueous Extract) |
- |
1725 |
|
1725 |
5, Table 1(Air permeability) |
- |
1150 |
|
1150 |
5, Table 1(Water absorption) |
- |
920 |
|
920 |
5, Table 1(Electric strength) |
- |
1150 |
|
1150 |
5, Table 1(Dissipation factor of dry un impregnated paper) |
- |
2875 |
|
2875 |
5, Table 1(Heat Stability) |
- |
10350 |
|
10350 |
|
Complete
|
|
30 Nov, 2025 |
- Exclusion: 5, Table 1 (Edge Tearing Resistance), Cl. 5, Table 1 (Folding Endurance), Cl.5, Table 1 (Chloride content of aqueous extract), Cl. 5, Table 1 (Conductivity of Organic Extract), Cl. 5, Table 1 (Dissipation factor of orgainic extract), Cl. 5, Table 1 (Dissipation factor & Permittivity of impregnated paper), Cl. 5, Table 1 (Conducting Path) |
138 |
IS 11170 (1985) |
Specification for 1 performance requirements for constant speed compression ignition (Diesel) engines for agricultural purposes (Up To 20 KW) |
upto 110 kW |
-
|
99558 View breakup
For all tests: Rs. 99,558/- ** (Up to 110 kW) ;
Only performance test Rs. 21,700/- .
For initial Performance test Rs. 3,000/- will be charge extra.
** Fuel & Oil charges for all test will be at actual.
Note: Presence of skill person is required for dismantle/assembly of engine.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking) |
- |
500 |
|
Nil |
3.1(a) Preparation for tests according to IS : 10000 (Part 5)-1980) |
- |
6394 |
|
Nil |
3.1(b) Preliminary run according to IS : 10000 (Part 5)-1980) |
- |
12500 |
|
Nil |
3.1(c) Initial performance test according to Section I of IS : 10000 (Part 8)-1980 ) |
- |
8700 |
|
Nil |
3.1(d) Endurance test according to Section 1 of IS : 10000 (Part 9)-1980 ) |
- |
54800 |
|
Nil |
3.1(e) Final performance test according to Section 1 or IS : 10000 (Part 8)-1980;) |
- |
8600 |
|
Nil |
3.1(f) Final inspection test according to IS : 10000 (Part 6)-1980 ) |
- |
4700 |
|
Nil |
3.1(g) Lubricating oil consumption according to IS : 10000 (Part 4)-1980.) |
- |
3364 |
|
Nil |
4.1(Power) |
- |
0 |
|
Nil |
4.2(SFC) |
- |
0 |
|
Nil |
4.3(ml/hr) |
- |
0 |
|
Nil |
4.4(Governing) |
- |
0 |
|
Nil |
3.6.1(Power) |
- |
0 |
|
Nil |
3.6.2(SFC) |
- |
0 |
|
Nil |
3.6.3(Governing) |
- |
0 |
|
Nil |
3.6.4(SFC, Governing) |
- |
0 |
|
Nil |
|
Complete
|
|
30 Nov, 2025 |
- - |
139 |
IS 10805 (1986) |
Specification for foot - Valves, reflux valves or non - Return valves and bore valves to be used in suction lines of agricultural pumping systems (First Revision) |
Size: 4” (Internal thread check up to 3”) |
-
|
6500 View breakup
Rs. 6,000/- for size upto 2 inch ;
Rs. 6,500/- for size above 2 inch.
Installation charges will be Rs. 3000/- Extra.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
(Cl. 2 Table 1)(Dimensions) |
- |
500 |
|
NA |
(Cl. 2 Table 1)(Dimensions) |
- |
500 |
|
NA |
(Cl. 2 Table 1)(Dimensions) |
- |
500 |
|
NA |
(Cl. 5)(Coating) |
- |
0 |
|
NA |
6.1.1(Seat test) |
- |
0 |
|
NA |
6.1.2(Housing test) |
- |
3000 |
|
NA |
6.2(K-Value Test for Foot-Valves and Bore Valves) |
- |
3000 |
|
NA |
8(Observation) |
- |
500 |
|
NA |
4.2(Observation) |
- |
1000 |
|
NA |
|
Complete
|
|
30 Nov, 2025 |
- - |
140 |
IS 11501 (1986) |
Specification for engine monoset pumps for clear, cold, fresh water for agricultural purposes |
Rated power: up to 20 kW, Size: 4” |
-
|
65498 View breakup
Single cylinder- Rs. 55,147/-** ;
Double cylinder-Rs. 65,498/- **;
** Fuel & Oil charges for all test will be at actual.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1(Direction of rotation) |
- |
500 |
|
Nil |
6.1(Direction of rotation) |
- |
500 |
|
Nil |
9.1(Design Features) |
- |
0 |
|
Nil |
9.1(Design Features) |
- |
0 |
|
Nil |
10.2(Casing) |
- |
954 |
|
Nil |
10.3(Impeller) |
- |
0 |
|
Nil |
10.4(Shaft) |
- |
0 |
|
Nil |
11.3.2.1(Pump Testing) |
- |
4882 |
|
Nil |
11.3.2.3(Pump Testing) |
- |
4882 |
|
Nil |
11.4.2.1(Pump Testing) |
- |
4882 |
|
Nil |
11.4.2.1(Pump Testing) |
- |
4882 |
|
Nil |
11.4.2.2(Pump Testing) |
- |
4882 |
|
Nil |
11.4.2.5(Pump Testing) |
- |
4882 |
|
Nil |
14(MARKING) |
- |
500 |
|
Nil |
14(MARKING) |
- |
500 |
|
Nil |
14(MARKING) |
- |
500 |
|
Nil |
14(MARKING) |
- |
500 |
|
Nil |
14(MARKING) |
- |
500 |
|
Nil |
14(MARKING) |
- |
500 |
|
Nil |
14(MARKING) |
- |
500 |
|
Nil |
14(MARKING) |
- |
500 |
|
Nil |
14(MARKING) |
- |
500 |
|
Nil |
14(MARKING) |
- |
500 |
|
Nil |
11.3.1(Time) |
- |
4312 |
|
NA |
5.1(Material of Construction) |
- |
0 |
|
Nil |
5.1(Gaskets, Seals and Packings) |
- |
0 |
|
Nil |
|
Complete
|
|
30 Nov, 2025 |
- - |
141 |
IS 10322 : Part 5 : Sec 4 (1987) |
Specification for luminaires: Part 5 particular requirements: Sec 4 portable general purpose luminaires |
- |
-
|
60000 View breakup
Rs. 60,000/-(Except Vibration Test)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking) |
- |
500 |
|
NA |
6(Construction) |
- |
27880 |
|
Above test charges included charges of CONSTRUCTION, TERMINALS, EXTERNAL & INTERNAL WIRING: 2000, charges of vibration test: 25880.
Total test charges: (2000+25880)=27880. |
7(Creepage Distance
And Clearances) |
- |
500 |
|
NA |
8(Provision for
Earthing) |
- |
500 |
|
NA |
9(Terminals) |
- |
0 |
|
NA |
10(External &
Internal Wiring) |
- |
0 |
|
NA |
11(Protection Against
Electric Shock ) |
- |
500 |
|
NA |
13.4(Endurance Test
and Thermal test) |
- |
17600 |
|
Above test charges included charges of endurance test: 11600, charges of thermal normal test: 3000, charges of thermal abnormal test: 3000.
Total test charges=(11600+3000+3000)= 17600. |
13.5(Resistance To
Dust & Moisture) |
- |
9000 |
|
Above test charges included charges of IP1X/2X/3X/4X: 1500, charges of IPX1/X2: 2000, charges of RESISTANCE TO MOISTURE: 5500.
Total test charges=(1500+2000+5500)=9000 |
13.6(Insulation Resistance
and Electric Strength) |
- |
1000 |
|
NA |
13.7(Resistance to Heat,
Fire & Tracking) |
- |
12070 |
|
Above test charges included charges of RESISTANCE TO HEAT: 1500, charges of NEEDLE FLAME TEST: 3500, charges of GLOW WIRE TEST: 5000, charges of RESISTANCE TO TRACKING: 2070.
Total test charges= (1500+3500+5000+2070)= 12070 |
13.8(Photometric Test) |
- |
20000 |
|
NA |
13.3(Mechanical
Strength Test ) |
- |
0 |
|
NA |
Cl. No. 13.2(Visual inspection) |
- |
0 |
|
NA |
|
Complete
|
|
30 Nov, 2025 |
- - |
142 |
IS 1554 : Part 2 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 2 for working voltages from 3.3 kV up to and including 11 kV (Second Revision) |
- |
-
|
275100 View breakup
Rs. 2,28,450/- for 1 Core (upto 11 kV) ;
Rs. 2,75,100/- for 3 Core (upto 11 kV) ;
Multicore cables: additional charges Rs. 500/- per core per test.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
18.1 a) 1)(Tests on Conductor : Annealing test (for copper)) |
- |
900 |
|
NA |
18.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
900 |
|
NA |
18.1 a) 3)(Tests on Conductor : Wrapping test ( for aluminium)) |
- |
500 |
|
NA |
18.1 a)4)(Tests on conductor : Conductor resistance test - Main conductor ) |
- |
1300 |
|
NA |
18.1 d) 1)(Phyaical tests for insulation : Tensile Test) |
- |
2000 |
|
NA |
18.1 d) 5)( Loss of mass in air oven- Insulation ) |
- |
8600 |
|
NA |
11.3(INSULATION : Tolerance on Thickness of Insulation) |
- |
1300 |
|
NA |
11.2(INSULATION : Thickness of Insulation) |
- |
0 |
|
NA |
15.4(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
0 |
|
NA |
16.3(Armouring : Dimensions -Wire Diameter) |
- |
555.55 |
|
NA |
16.3(Armouring : Dimensions -Formed wire ) |
- |
555.55 |
|
NA |
13.6 a)(ARMOURING: Tensile Strength) |
- |
555.55 |
|
NA |
13.6 b)(ARMOURING: Elongation ) |
- |
555.55 |
|
NA |
13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
555.55 |
|
NA |
13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
555.55 |
|
NA |
13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
555.55 |
|
NA |
13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
555.55 |
|
NA |
13.6 g)(ARMOURING: Resistivity) |
- |
555.55 |
|
NA |
17.3.1(Thickness of Outer Sheath : Unarmoured Cables) |
- |
1300 |
|
NA |
17.3.2(Thickness of Outer Sheath : Armoured Cables) |
- |
1300 |
|
NA |
18.1 a)4)(Resistance test - Neutral conductor ) |
- |
1300 |
|
NA |
18.1 d) 1)(Phyaical tests for insulation : Elongation ) |
- |
2000 |
|
NA |
18.1 d) 2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
8600 |
|
NA |
18.1 d) 2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
0 |
|
NA |
18.1 d) 2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
8600 |
|
NA |
18.1 d) 2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
0 |
|
NA |
18.1 d) 2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
0 |
|
NA |
18.1 d) 2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
0 |
|
NA |
18.1 d) 3)(Phyaical tests for insulation : Shrinkage ) |
- |
1300 |
|
NA |
18.1 d) 3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
0 |
|
NA |
18.1 d) 3)(Phyaical tests for Sheath : Shrinkage ) |
- |
1300 |
|
NA |
18.1 d) 3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
0 |
|
NA |
18.1 d) 4)(Hot deformation : Insulation ) |
- |
1900 |
|
NA |
18.1 d) 5)( Loss of mass in air oven- sheath ) |
- |
8600 |
|
NA |
18.1 d) 6)(Heat shock test- Insulation ) |
- |
1300 |
|
NA |
18.1 d) 6)(Heat shock test- sheath ) |
- |
1300 |
|
NA |
18.1 d) 7)(Thermal stability- insulation ) |
- |
1900 |
|
NA |
18.1 d) 8)(Water absorption (gravimetric)(for insulation, where applicable)) |
- |
10300 |
|
NA |
18.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
2700 |
|
NA |
18.1 e)(Insulation resistance test : IR Constant ) |
- |
0 |
|
NA |
19.2(Partial discharge test) |
- |
10500 |
|
10500 for 3 core
5250 for 1 core |
19.3(Bending test) |
- |
3150 |
|
3150 for 3 core
2100 for 1 core |
19.4(Dielectric power factor test) |
- |
10500 |
|
10500 for 3 core
5250 for 1 core |
19.4(Dielectric power factor test) |
- |
12600 |
|
12600 for 3 core
8400 for 1 core |
19.5(Heating cycle test) |
- |
8400 |
|
NA |
19.6(Impulse withstand test) |
- |
36750 |
|
36750 above 11 kV
27300 up to 11 kV |
19.7(High voltage test) |
- |
6300 |
|
6300 for 3 core
3150 for 1 core |
19.8(Flammability test) |
- |
1500 |
|
NA |
19.9(Oxygen Index Test) |
- |
3750 |
|
NA |
19.10(Flame Retardance Test on Single Cables) |
- |
7500 |
|
NA |
19.11(Flame Retardance Test on Bunched Cables) |
- |
10000 |
|
NA |
19.13(Test for Halogen Acid Gas Evolution) |
- |
5000 |
|
NA |
19.14(Temperature Index) |
- |
6250 |
|
Na |
|
Complete
|
|
30 Nov, 2025 |
- - |
143 |
IS 6595 : Part 2 (1993) |
Horizontal centrifugal pumps for clear, cOld water: Part 2 general pmUrpose (Other than agricultural and rural water supply) - Specification (Second Revision) |
Voltage: upto 440V, Power upto 110 kW, Size: 5'' |
-
|
15985 View breakup
Upto 5.5 kW : Rs. 6,000/-;
5.51 to 11 kW : Rs. 6,700/- ;
11.1 to 22 kW : Rs. 7,200/-;
22.1 to 45 kW : Rs. 8,645/-;
45.1 to 75 kW : Rs. 12,650/-;
75.1 to 110 kW : Rs. 15,985/- ;
Installation charges will be Rs. 3000/- Extra.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1(Direction of Rotation) |
- |
690 |
|
Nil |
8.1(Design Limitations) |
- |
0 |
|
Nil |
9.1(General Requirements) |
- |
2530 |
|
Nil |
10.1(Pump test, tolerances, and verification of guarantee on Pump Performance) |
- |
9200 |
|
Nil |
10.4(Hydrostatic Test) |
- |
2875 |
|
Nil |
7.2(Direction of Rotation) |
- |
690 |
|
Nil |
9.2(General Requirements) |
- |
0 |
|
Nil |
9.3(General Requirements
Shaft) |
- |
0 |
|
Nil |
9.4(General Requirements) |
- |
0 |
|
Nil |
9.5(General Requirements) |
- |
0 |
|
Nil |
9.6(General Requirements) |
- |
0 |
|
Nil |
9.7(General Requirements) |
- |
0 |
|
Nil |
8.2(Design Limitations
Suction Limitations) |
- |
0 |
|
Nil |
8.2(Design Limitations
Suction Limitations) |
- |
0 |
|
Nil |
8.3(Design Limitations) |
- |
0 |
|
Nil |
6.1(Observation) |
- |
2530 |
|
NA |
14(Observation) |
- |
690 |
|
NA |
|
Complete
|
|
30 Nov, 2025 |
- - |
144 |
IS 7538 (1996) |
Three - Phase squirrel cage induction motors for centrifugal pumps for agricultural application - Specification (First Revision) |
Up to 110 kW 2 & 4 pole, 90 kW 6 pole, 75 kW 8 pole |
-
|
119071 View breakup
Up to 5.5kW : Rs. 10,820/- ;
5.5kW to 11kW : Rs. 12,160/- ;
11kW to 22kW : Rs. 20,126/- ;
22.1kW to 45kW : 39,300/- ;
45.1kW to 75kW : Rs. 59,950/- ;
75.1kW to 110kW : Rs. 1,19,071/- .
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
20.1( MARKING) |
- |
1000 |
|
NA |
11(PROVISION FOR EARTHING) |
- |
1000 |
|
NA |
22.3.1 b)(Measurement of stator resistance) |
- |
1200 |
|
NA |
24.1(No-load running of motor and reading of
' voltage) |
- |
2000 |
|
NA |
24.1(No-load running of motor and reading of
' current ) |
- |
2000 |
|
NA |
24.1(No-load running of motor and reading of
' power input ) |
- |
2000 |
|
NA |
24.1(No-load running of motor and reading of
' speed ) |
- |
2000 |
|
NA |
24.2(Reduced Voltage Running Up Test) |
- |
1500 |
|
NA |
24.4(Full Load Test : voltage) |
- |
10000 |
|
NA |
24.4(Full Load Test : Power input ) |
- |
10000 |
|
NA |
24.4(Full Load Test : current ) |
- |
10000 |
|
NA |
24.4(Full Load Test : speed) |
- |
10000 |
|
NA |
24.5(Test for efficiency at reduced load) |
- |
10000 |
|
NA |
13.1(OVERLOAD:Momentary Excess Torque) |
- |
4000 |
|
NA |
23.1(TEMPERATURE-RISE TEST : Test at Rated Voltage) |
- |
14000 |
|
NA |
23.2(TEMPERATURE-RISE TEST: Test at Reduced Voltage) |
- |
14000 |
|
NA |
24.3(Locked Rotor Test:The readings of the input
current) |
- |
4500 |
|
NA |
24.3(Locked Rotor Test:The readings of the input
power) |
- |
4500 |
|
NA |
24.3(Locked Rotor Test:The readings of the breakaway rotor torque) |
- |
4500 |
|
NA |
25(HIGH-VOLTAGE TEST) |
- |
800 |
|
NA |
26(INSULATION-RESISTANCE TEST) |
- |
800 |
|
NA |
15(LIMITS OF VIBRATION SEVERITY) |
- |
6000 |
|
NA |
9(DIMENSIONS- H : Nominal ) |
- |
5000 |
|
NA |
9(DIMENSIONS- H : Deviation ) |
- |
5000 |
|
NA |
9(DIMENSIONS- A) |
- |
5000 |
|
NA |
9(DIMENSIONS- B) |
- |
5000 |
|
NA |
9(DIMENSIONS- C) |
- |
5000 |
|
NA |
9(DIMENSIONS- K+ : Nominal ) |
- |
5000 |
|
NA |
9(DIMENSIONS- K+ : Tolerance ) |
- |
5000 |
|
NA |
9(DIMENSIONS- Bolt or Screw) |
- |
5000 |
|
NA |
9(DIMENSIONS- M) |
- |
5000 |
|
NA |
9(DIMENSIONS- N) |
- |
5000 |
|
NA |
9(DIMENSIONS- P) |
- |
5000 |
|
NA |
9(DIMENSIONS- S) |
- |
5000 |
|
NA |
9(DIMENSIONS- T) |
- |
5000 |
|
NA |
9(DIMENSIONS- LA) |
- |
5000 |
|
NA |
9(DIMENSIONS- Depth of tapped Hole) |
- |
5000 |
|
NA |
27(OVERSPEED TEST) |
- |
4000 |
|
NA |
19.1.1(TERMINAL
MARKINGS) |
- |
1000 |
|
NA |
5(ENCLOSURES) |
- |
38271 |
|
NA |
|
Complete
|
|
30 Nov, 2025 |
- - |
145 |
IS 2993 (1998) |
A.C. motor capacitors (Second Revision) |
Up to 100 µF |
-
|
478760 View breakup
Type Tests : for Class A : Rs. 4,78,760/-, for Class B : Rs. 2,28,760/-, for Class C : Rs. 1,78,760/-, for Class D : Rs. 1,28,760/-, Routine Test for one capacitor: Rs. 11,177/-.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
2.9(Capacitance measurement) |
- |
3000 |
|
RS. |
2.1(Check of dimensions) |
- |
720 |
|
RS. |
2.14(Damping heat test) |
- |
12000 |
|
RS. |
2.16.3(Destruction test : Test procedure) |
- |
30000 |
|
RS. |
2.13(Endurance test) |
- |
380000 |
|
30,000/- for Class D, 80,000/- for Class C, 1,30,000/- for Class B, 3,80,000/- for Class A |
2.5(Tangent of loss angle) |
- |
3000 |
|
RS. |
2.12(Sealing Test) |
- |
1800 |
|
RS. |
2.15(Self-healing test (if applicable)) |
- |
3000 |
|
RS. |
2.6(Visual Examination) |
- |
720 |
|
RS. |
5.1(Check marking) |
- |
720 |
|
RS. |
2.7(Voltage test between terminals) |
- |
1200 |
|
RS. |
2.8(Voltage test between terminals and case) |
- |
1200 |
|
RS. |
2.11.1.1(Tensile) |
- |
1960 |
|
RS. |
2.11.1.2(Bending (half cf the terminations)) |
- |
1960 |
|
RS. |
2.11 .1.3(Torsion (other half of the terminations)) |
- |
1960 |
|
RS. |
2.11.1.4(Torque (screw terminals)) |
- |
1960 |
|
RS. |
2.11.3(Vibration) |
- |
25880 |
|
RS. |
2.11.2(Soldering) |
- |
2150 |
|
RS. |
|
Complete
|
|
30 Nov, 2025 |
- - |
146 |
IS 8309 (1993) |
Compression type tubular terminal ends for aluminium conductors of insulated cables - Specification (First Revision) |
- |
-
|
3740 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(Finish, IS 8309) |
- |
170 |
|
Complete test charges - 3740/- |
5(Dimensions, IS 8309) |
- |
300 |
|
Complete test charges - 3740/- |
8.2(Flattening Test, IS 8309) |
- |
630 |
|
Complete test charges - 3740/- |
8.3(Electrical Conductivity Test, IS 8309) |
- |
340 |
|
Complete test charges - 3740/- |
|
Complete
|
|
30 Nov, 2025 |
- 0.0 |
147 |
IS 398 : Part 5 (1992) |
Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) |
- |
-
|
178960 View breakup
Rs. 1,59,880/- [560 to 690 sq. mm.] & Rs. 1,78,960/- [520 sq. mm.]
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7 (elec)(Freedom from
defects) |
- |
125 |
|
159880/-
560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.3 Table-1 (mech)(Diameter-Aluminium wires) |
- |
125 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.3 Table-2 (mech)(Diameter-Galvanized Steel wires) |
- |
125 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.4 Table-4 (mech)(Lay Ratio- Aluminium Wire Outermost Layer) |
- |
250 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.4 Table-4 (mech)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
250 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.4 Table-4 (mech)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors eith 3 Aluminium Wire Layers) |
- |
250 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.4 Table-4 (mech)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
250 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.5.1 Table 3 (elec)(Breaking Load on Complete conductor) |
- |
360 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.5.2 Table 1 (mech)(Breaking Load of Aluminium Wires Before Stranding) |
- |
360 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.5.2 Table 1 (mech)(Breaking Load of Aluminium Wires After Stranding) |
- |
360 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.5.2 Table 2 (mech)(Breaking Load of Steel Wires After Stranding) |
- |
360 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.6.1 (mech)(Ductility by Torsion Test before stranding) |
- |
460 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.6.1 (mech)(Ductility by Torsion Test after stranding) |
- |
460 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.6.2 (mech)(Ductility by Elongation Test before stranding) |
- |
360 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.6.2 (mech)(Ductility by Elongation Test after stranding) |
- |
360 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.7.1 (mech)(Wrapping Test Aluminium Wires Before Stranding) |
- |
460 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.7.1 (mech)(Wrapping Test Aluminium Wires After Stranding) |
- |
460 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.7.2 (mech)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
460 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.7.2 (mech)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
460 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.8 (elec)(Resistance test-Aluminium wire before Stranding) |
- |
520 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
14.8 (elec)(Resistance test-Aluminium wire after stranding) |
- |
520 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.9.2 (chem)(Mass of Zinc coating) |
- |
340 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.9.2 (chem)(Uniformity of Zinc coating) |
- |
340 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.10 (elec)(Surface condition test) |
- |
14490 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.11 (elec)(Corona Test) |
- |
19200 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.12 (elec)(Radio Interference Voltage Test) |
- |
42000 |
|
159880/- 560 to 690 sq. mm.
178960/-
520 sq. mm. |
10.4 (mech)(Direction of lay) |
- |
125 |
|
159880/-
560 to 690 sq. mm.
178960/-
520 sq. mm. |
13.5.2 Table 2 (mech)(Breaking Load of Steel Wires Before Stranding) |
- |
360 |
|
---- |
13.9 (elec)(The test of galvanising) |
- |
1210 |
|
170/- per wire
1210/- for 7 wires |
8.2.1 (elec)(Size of complete conductor) |
- |
125 |
|
-- |
8.2.2 (elec)(Resistance of complete conductor) |
- |
5200 |
|
-- |
|
Complete
|
|
30 Nov, 2025 |
- - |
148 |
IS 398 : Part 4 (1994) |
Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
- |
-
|
73250 View breakup
Rs. 6,585/- [15 sq. mm.],
Rs. 11,105/-[22, 34, 55, 80 & 100 sq. mm.],
Rs. 25,040/-[125,148,173, 200 & 232 sq. mm],
Rs. 45,755/-[288, 346, 400 & 465 sq. mm.],
Rs. 73,250/- [525, 570, 604, 642, 695 & 767 sq. mm.]
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1(Freedom from Defects) |
- |
125 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
7.1 Table-1(Dimensional measurement of wires) |
- |
125 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
7.2.2 Table-2, Table-4(Calculated resistance of Stranded Conductor) |
- |
520 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
9.3(Direction of Lay) |
- |
125 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
9.2 Table 3(Lay Ratio of stranded conductors) |
- |
250 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
12.2 Table 1(Breaking Load Test- Before Stranding) |
- |
360 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
12.2 Table 1(Breaking Load Test- After Stranding) |
- |
360 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
12.3 Table 1(Elongation Test- Before Stranding) |
- |
360 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
12.3 Table 1(Elongation Test- After Stranding) |
- |
360 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
12.4 Table 1(Resistance of Aluminium wire) |
- |
520 |
|
Complete conductor test charges :
6585/-
15 sq. mm.
11105/-
22, 34, 55, 80 & 100 sq. mm.
25040/-
125, 148, 173, 200 & 232 sq. mm
45755/-
288, 346, 400 & 465 sq. mm.
73250/-
525, 570, 604, 642, 695 & 767 sq. mm. |
|
Complete
|
|
30 Nov, 2025 |
- - |
149 |
IS 398 : Part 2 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
- |
-
|
166060 View breakup
Rs. 14,605/-[10, 18, 30, 50 & 80 sq. mm], Rs. 88,990/-[100 sq. mm], Rs. 1,27,525/-[150 & 200 sq. mm], Rs. 1,46,980/- [400 & 560 sq. mm.] & Rs. 1,66,060/- [420 & 520 sq. mm.]
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires Before Stranding) |
- |
125 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires Before Stranding) |
- |
125 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires After Stranding) |
- |
125 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires After Stranding) |
- |
125 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
10 (elec)(Stranding) |
- |
125 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
10 (elec)(Stranding) |
- |
125 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
10 (elec)(Stranding) |
- |
125 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
10 (mech)(Stranding) |
- |
125 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.3 Table 1 (mech)(Breaking Load of Aluminium Wires Before Stranding) |
- |
360 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.3 Table 2 (mech)(Breaking Load of Steel Wires Before Stranding) |
- |
360 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.3 Table 1 (mech)(Breaking Load of Aluminium Wires After Stranding) |
- |
360 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.3 Table 2 (mech)(Breaking Load of Steel Wires After Stranding) |
- |
360 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
460 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
460 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.4.2 (elec)(Ductility by Elongation Test before stranding) |
- |
460 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.4.2 (elec)(Ductility by Elongation Test after stranding) |
- |
460 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.5.1 (mech)(Wrapping Test Aluminium Wires Before Stranding) |
- |
460 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.5.1 (mech)(Wrapping Test Aluminium Wires After Stranding) |
- |
460 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.5.2 (mech)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
460 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.5.2 (mech)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
460 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.6 (elec)(Resistance test-Aluminium wire before Stranding) |
- |
520 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.6 (elec)(Resistance test-Aluminium wire after stranding) |
- |
520 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.7.2 (chem)(Mass of Zinc coating) |
- |
340 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.7.2 (chem)(Uniformity of Zinc coating) |
- |
340 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Outermost Layer) |
- |
250 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
250 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
250 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.8 Table-4 (mech)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
250 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.9 (elec)(Surface condition test) |
- |
14490 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.10 (elec)(Ultimate breaking load) |
- |
14490 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
13.11 (elec)(Stress-strain test) |
- |
48300 |
|
For complete test charges :
14605/-
10, 18, 30, 50 & 80 sq. mm
88990/-
100 sq. mm
127525/-
150 & 200 sq. mm
146980/-
400 & 560 sq. mm.
166060/-
420 & 520 sq. mm. |
|
Complete
|
|
30 Nov, 2025 |
- - |
150 |
IS 398 : Part 1 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) |
- |
-
|
33780 View breakup
Rs. 14,325/- [25, 50 & 100 sq. mm] & Rs. 33,780/-[150, 240 & 300 sq. mm]
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12.2, Table-1(Measurement of diameter of individual aluminium wire) |
- |
125 |
|
Complete test charges by considering all tests
14325/-
25, 50 & 100 sq. mm
33780/-
150, 240 & 300 sq. mm |
12.3, Table-1(Breaking load before stranding) |
- |
360 |
|
Complete test charges by considering all tests
14325/-
25, 50 & 100 sq. mm
33780/-
150, 240 & 300 sq. mm |
12.3, Table-1(Breaking load after stranding) |
- |
360 |
|
Complete test charges by considering all tests
14325/-
25, 50 & 100 sq. mm
33780/-
150, 240 & 300 sq. mm |
12.5, Table 1(Resistance test) |
- |
520 |
|
Complete test charges by considering all tests
14325/-
25, 50 & 100 sq. mm
33780/-
150, 240 & 300 sq. mm |
12.6, Table 3(Measurement of lay ratio) |
- |
250 |
|
Complete test charges by considering all tests
14325/-
25, 50 & 100 sq. mm
33780/-
150, 240 & 300 sq. mm |
12.4(Wrapping test) |
- |
460 |
|
Complete test charges by considering all tests
14325/-
25, 50 & 100 sq. mm
33780/-
150, 240 & 300 sq. mm |
6(Freedom from defects) |
- |
125 |
|
Complete test charges by considering all tests
14325/-
25, 50 & 100 sq. mm
33780/-
150, 240 & 300 sq. mm |
9.3(Stranding) |
- |
125 |
|
Complete test charges by considering all tests
14325/-
25, 50 & 100 sq. mm
33780/-
150, 240 & 300 sq. mm |
|
Complete
|
|
30 Nov, 2025 |
- 0.0 |