1 |
IS 16651 (2017) |
High Strength Deformed Stainless Steel Bars and Wires for Concrete Reinforcement - Specification |
- |
-
|
31000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 4.4(Surface Quality) |
- |
0 |
|
- |
Cl 5.2(Deformations and Surface Characteristics) |
- |
1000 |
|
- |
Cl 5.7(Pull out test) |
- |
15000 |
|
- |
Cl 6.1(Nominal size) |
- |
0 |
|
- |
Cl 7.2 / Table 3(Nominal mass) |
- |
1000 |
|
- |
Cl 8.2 / Table 5(Physical Properties) |
- |
3000 |
|
- |
Cl 8.3(Bend test) |
- |
1000 |
|
- |
Cl 8.3(Rebend test) |
- |
1000 |
|
- |
Cl 8.4(Bond Strength) |
- |
0 |
|
- |
Cl 8.6(Charpy Impact Test) |
- |
5000 |
|
- |
4.1(Designation) |
- |
0 |
|
- |
4.2(Manufacture) |
- |
0 |
|
- |
4.3(Chemical Composition) |
- |
4000 |
|
- |
6.2(The values for the nominal cross-sectional area) |
- |
0 |
|
- |
9.5(Retests) |
- |
0 |
|
- |
12(Identification and Marking) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
2 |
IS 1660 (2009) |
Wrought aluminium utensils - Specification (First Revision) |
- |
-
|
31100 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(Classification Heavy/Medium/L:ight) |
- |
500 |
|
- |
4(Material) |
- |
3000 |
|
- |
0.5(Fabrication) |
- |
0 |
|
- |
5.1(The utensil shall be pressed or spun from one piece) |
- |
200 |
|
- |
5.2( Body Thickness of the thinnest part of the finished utensil, mm Not declared ) |
- |
500 |
|
- |
5.2(Lid Thickness of the finished utensil, mm) |
- |
500 |
|
- |
6.1 & Table 1( i) Name of Utensil ) |
- |
0 |
|
- |
6.1 & Table 1(ii) Shape of Utensil) |
- |
0 |
|
- |
6.1 & Table 1( Nominal Size, mm) |
- |
200 |
|
- |
6.1 & Table 1(Inside dia, Φ D mm Not declared ) |
- |
200 |
|
- |
6.1 & Table 1(Outside dia Ф NA) |
- |
200 |
|
- |
6.1 & Table 1(Height NA) |
- |
200 |
|
- |
6.1 & Table 1(Capacity, l NA) |
- |
500 |
|
- |
6.1( Minimum sheet thickness for nominal size ) |
- |
500 |
|
- |
7.1(HANDLES ,When fitted shall be of aluminium, stainless steel or of other suitable fire resistance material These shall be fastened to the utensils by tightly drawn aluminium or stainless steel rivets, by welding, by screwing to cast bosses or by riveting between flange at the end of the handles. Handles shall be so shaped and positioned to facilitate the carrying and handling of the utensils in normal use ) |
- |
200 |
|
- |
7.2(Handles shall be sufficiently strong to support a mass in the utensils equivalent to three times the mass of the water capacity of the utensils in the position of normal use without visible permanent deformation of the handle or utensil) |
- |
500 |
|
- |
8.1(The utensils shall be clean reasonably free from distortion, dents, wrinkles, wavy surface, burrs, scratches, pitting and deep tool marks and other surface defects) |
- |
200 |
|
- |
8.2(The design of the utensils shall be such that it is easy to clean and prevent accumulation of dirt) |
- |
200 |
|
- |
8.4.1.2( Finish of the coating: The coating shall be smooth continuous and uniform in appearance, and shall be adherent. It shall be free from powdery areas, loose films and discontinuities, such as breaks and scratches. The size and number of contact marks shall be minimum consistent with good practice.) |
- |
500 |
|
- |
8.4.2(A coating of thickness 25 to 100 microns is generally required) |
- |
2500 |
|
- |
8.4.3(Abrasion Resistance When the coating surface is rubbed two or three times with emery paper with emery conforming to grit number 180 using medium finger pressure, it shall not abrade the surface but shall skid over the surface showing not more than a trace of whitening of the surface) |
- |
500 |
|
- |
8.4.4(The colour of the hard anodic coating varies depending upon the alloy, thickness of the coating and electrolye. Normally the colour may vary from dark grey (almost black) to light grey. ) |
- |
0 |
|
- |
8.4.4(The film will appear dark grey when wet. ) |
- |
0 |
|
- |
8.4.5 (When the coated surface is rubbed two or three times with fine emery paper grit number 180 using medium finger pressure, cloth or paper shall not abrade the surface. A faint trace of whitening on the cloth or paper is permissible) |
- |
500 |
|
- |
9(The manufacturer shall provide full instructions for use and cleaning for coated or hard anodized utensils) |
- |
0 |
|
- |
10(Each vessel shall be legibly and indelibly stamped on the outside surface or handle with the manufacturer’s name or registered trade-mark, size and thickness or class. ) |
- |
0 |
|
- |
Clause 3.1.3, Table 2(Minimum Thickness at the bottom) |
- |
500 |
|
- |
Clause 3.1.3, Table 2(Minimum Thickness of wall at top edge) |
- |
500 |
|
- |
Clause 3.1.3, Table 2(Minimum Cover Thickness) |
- |
500 |
|
- |
Clause 8.6.1(Performance test) |
- |
2000 |
|
- |
Clause 8.6.2(Ground Nut Oil Test for Leakage) |
- |
2000 |
|
- |
5.4(Qualitative and Anodized Coating) |
- |
2000 |
|
- |
5.5(Qualitative and Anodized Coating) |
- |
2000 |
|
- |
8.3(Anodized Coating) |
- |
2000 |
|
- |
8.5(Plastic Coating) |
- |
8000 |
|
- |
|
Complete
|
|
- |
- |
3 |
IS 14756 (2022) |
Draft Indian Standard STAINLESS STEEL COOKWARE SPECIFICATION Second Revision of IS 14756 |
- |
-
|
36300 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(Material) |
- |
3000 |
|
- |
3.2(Material) |
- |
3000 |
|
- |
3.3(Material) |
- |
3000 |
|
- |
3.4(Material) |
- |
3000 |
|
- |
3.5(Material) |
- |
3000 |
|
- |
4.1 (Annex A)(Shapes and Dimensions) |
- |
500 |
|
- |
4.2 (Table 1)(Shapes and Dimensions) |
- |
1000 |
|
- |
4.3(Shapes and Dimensions) |
- |
1000 |
|
- |
4.4(Shapes and Dimensions) |
- |
1000 |
|
- |
5.1(Workmanship and Finish) |
- |
200 |
|
- |
5.2(Workmanship and Finish) |
- |
200 |
|
- |
5.3(Workmanship and Finish) |
- |
200 |
|
- |
5.6(Workmanship and Finish) |
- |
200 |
|
- |
6.1(Staining Test) |
- |
2000 |
|
- |
6.2(Mechanical Shock Test (For Cladded Utensils only)) |
- |
1000 |
|
- |
6.3(Thermal Shock Test (For Cladded Utensils only)) |
- |
2000 |
|
- |
6.4(Dry Heat Test (For Cladded Utensils only)) |
- |
3000 |
|
- |
6.5(Coating Thickness Test (For Copper Deposit)) |
- |
1000 |
|
- |
6.6(3 Ply) |
- |
3000 |
|
- |
6.7.1(Nominal Capacity Test) |
- |
1000 |
|
- |
6.8.1(Tests on Tempered Glass Lid) |
- |
500 |
|
- |
6.8.2(Tests on Tempered Glass Lid (Ball drop test)) |
- |
500 |
|
- |
6.8.3(Tests on Tempered Glass Lid (thermal shock test)) |
- |
2000 |
|
- |
6.8.4.1(Tests on Tempered Glass Lid (Free Fall Test with rim facing down)) |
- |
500 |
|
- |
6.8.4.2(Tests on Tempered Glass Lid (Free Fall Test without rim facing down)) |
- |
500 |
|
- |
|
Complete
|
|
- |
- |
4 |
IS 1328 (1996) |
Veneered Decorative Plywood -Specification |
- |
-
|
5000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(Grade - For BWR) |
- |
1000 |
|
- |
4.1(Grade - For MR) |
- |
1000 |
|
- |
4.2(Type - For Type 1) |
- |
1000 |
|
- |
4.2(Type - For Type 2) |
- |
1000 |
|
- |
7.1.1(Requirements - Open splits, checks or open joints - For Type 1 - Cl. 7.1.1) |
- |
1000 |
|
- |
7.2.1(Requirements - Open splits, checks or open joints - For Type 2 - Cl. 7.2.1) |
- |
1000 |
|
- |
7.2.2(Requirements - Other defects - For Type 2 - Cl. 7.2.2.) |
- |
1000 |
|
- |
7.1.3(Requirements - Other Charcteristics and Manufacturing Defects - For Type 1 - Cl. 7.1.3) |
- |
1000 |
|
- |
7.2.3(Requirements - Other Charcteristics and Manufacturing Defects - For Type 2 - Cl. 7.2.3) |
- |
1000 |
|
- |
8(Dimensions & Tolerances - Length - Cl. 8) |
- |
1000 |
|
- |
8(Dimensions & Tolerances - Width - Cl. 8) |
- |
1000 |
|
- |
8(Dimensions & Tolerances - Thickness - Cl. 8) |
- |
1000 |
|
- |
8(Dimensions & Tolerances - Edge Straightness - Annexure C) |
- |
1000 |
|
- |
8(Dimensions & Tolerances - Squareness - Annexure C) |
- |
1000 |
|
- |
9(Finish - Cl. 9.1, 8.3) |
- |
1000 |
|
- |
9(Finish - Cl. 9.2, 8.3) |
- |
1000 |
|
- |
11(Tests - Moisture Content - Part 1 of IS 1734) |
- |
1000 |
|
- |
11(Tests - Water Resistance Test - Cl. 11.1.2.1 [for MR Grade]) |
- |
2000 |
|
- |
11(Tests - Water Resistance Test - Cl. 11.1.2.2 [for BWR Grade]) |
- |
2000 |
|
- |
7.1.2(Requirements - Other defects - For Type 1 - Cl. 7.1.2) |
- |
1000 |
|
- |
|
Complete
|
|
- |
- |
5 |
IS 1130 (1969) |
Marble (blocks, Slabs And Tiles) |
- |
-
|
5000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General Requirements) |
- |
500 |
|
- |
5(Sizes) |
- |
1000 |
|
- |
6(Tolerance) |
- |
500 |
|
- |
7.1-Table 1-(i)(Moisture absorption after 24 hours immersion in cold water) |
- |
1000 |
|
- |
7.1-Table 1-(ii)(Hardness) |
- |
2000 |
|
- |
7.1-Table 1-(iii)(Specific gravity) |
- |
1000 |
|
- |
8(Workmanship) |
- |
500 |
|
- |
9(Marking) |
- |
500 |
|
- |
|
Complete
|
|
- |
- |
6 |
IS 3316 (1974) |
Structural Granite |
- |
-
|
5000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
2(General Requirements) |
- |
1000 |
|
- |
3(Strength Requirements) |
- |
5000 |
|
- |
4.1(Slabs) |
- |
500 |
|
- |
4.2(Blocks for Masonry) |
- |
500 |
|
- |
5(Marking) |
- |
500 |
|
- |
|
Complete
|
|
- |
- |
7 |
IS 12894 (2002) |
Pulverized fuel ash - Lime bricks - Specification |
- |
-
|
7000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(General Requirements) |
- |
500 |
|
- |
3.2(General Requirements) |
- |
500 |
|
- |
3.3(General Requirements) |
- |
500 |
|
- |
3.4(General Requirements) |
- |
500 |
|
- |
3.5(General Requirements) |
- |
500 |
|
- |
5.1(Dimensions) |
- |
500 |
|
- |
7.1, Table -1(Average Wet Compressive Strength) |
- |
2000 |
|
- |
7.2(Drying Shrinkage) |
- |
2000 |
|
- |
7.3(Efflorescence Test) |
- |
1000 |
|
- |
7.4(Water Absorption) |
- |
1000 |
|
- |
5.2(Tolerance) |
- |
500 |
|
- |
9(Marking) |
- |
500 |
|
- |
6(Materials) |
- |
500 |
|
- |
|
Complete
|
|
- |
- |
8 |
IS 1077 (1992) |
Common burnt clay building bricks - Specification (Fifth Revision) |
- |
-
|
5000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(Common burnt clay bricks) |
- |
500 |
|
- |
5(General Quality) |
- |
500 |
|
- |
6.1(Dimensions) |
- |
1000 |
|
- |
6.2(Tolerances) |
- |
1000 |
|
- |
7.1(Compressive strength) |
- |
2000 |
|
- |
7.2(Water Absorption) |
- |
1000 |
|
- |
7.3(Efflorescence) |
- |
1000 |
|
- |
9(Marking) |
- |
500 |
|
- |
|
Complete
|
|
- |
- |
9 |
IS 2185 : Part 3 (1984) |
Concrete Masonry Units Part 3 Autoclaved Cellular Aerated Concrete Blocks |
- |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8(Physical requirments) |
- |
15000 |
|
- |
8.2(Physical requirments-Dimensions-Length) |
- |
1000 |
|
- |
8.2(Physical requirments-Dimensions-Height) |
- |
1000 |
|
- |
8.2(Physical requirments-Dimensions-Width) |
- |
1000 |
|
- |
8.3(Physical requirments- Block density) |
- |
3000 |
|
- |
8.4(Physical requirments- Compressive strength) |
- |
12000 |
|
- |
8.5(Thermal Conductivity) |
- |
0 |
|
No test facility at present |
8.6( Drying Shrinkage ) |
- |
2000 |
|
- |
8.4, 9.2 & 11.3(Indivisual Moisture Content) |
- |
1000 |
|
- |
8.4, 9.2 & 11.3(Indivisual Bulk density) |
- |
1000 |
|
- |
8.4, 9.2 & 11.3 & Table 1(Indivisual Compressive strength) |
- |
1000 |
|
- |
8.3 & 9.1(Indivisual Moisture Content) |
- |
1000 |
|
- |
8.3 & 9.1 Table 1(Indivisual Block Density) |
- |
1000 |
|
- |
3.2 & 8.2(Indivisual Height) |
- |
500 |
|
- |
3.2 & 8.2(Indivisual Width) |
- |
500 |
|
- |
3.2 & 8.2(Indivisual Length) |
- |
500 |
|
- |
8.6, 9.4 & 11.5(Grade) |
- |
500 |
|
- |
3.4(Special Faces) |
- |
500 |
|
- |
3.3(Faces & Arises) |
- |
1000 |
|
- |
3.1(Shape) |
- |
500 |
|
- |
8.1.1(General (Exposed wall construction)) |
- |
500 |
|
- |
5(MA TEIUA.LS) |
- |
44500 |
|
Cement Rs 10000
Flyash Rs 13500
Aggregates Rs 12000
Lime Rs 9000 |
7(SURI'ACE TUTUU AND FINISH) |
- |
1000 |
|
- |
9.3(Thermal Conductivity) |
- |
0 |
|
No facility |
15(Marking) |
- |
500 |
|
- |
8(Physical requirments) |
- |
15000 |
|
- |
8.2(Physical requirments-Dimensions-Length) |
- |
1000 |
|
- |
8.2(Physical requirments-Dimensions-Height) |
- |
1000 |
|
- |
8.2(Physical requirments-Dimensions-Width) |
- |
1000 |
|
- |
8.3(Physical requirments- Block density) |
- |
3000 |
|
- |
8.4(Physical requirments- Compressive strength) |
- |
12000 |
|
- |
8.5(Thermal Conductivity) |
- |
0 |
|
No test facility at present |
8.6( Drying Shrinkage ) |
- |
2000 |
|
- |
8.4, 9.2 & 11.3(Indivisual Moisture Content) |
- |
1000 |
|
- |
8.4, 9.2 & 11.3(Indivisual Bulk density) |
- |
1000 |
|
- |
8.4, 9.2 & 11.3 & Table 1(Indivisual Compressive strength) |
- |
1000 |
|
- |
8.3 & 9.1(Indivisual Moisture Content) |
- |
1000 |
|
- |
8.3 & 9.1 Table 1(Indivisual Block Density) |
- |
1000 |
|
- |
3.2 & 8.2(Indivisual Height) |
- |
500 |
|
- |
3.2 & 8.2(Indivisual Width) |
- |
500 |
|
- |
3.2 & 8.2(Indivisual Length) |
- |
500 |
|
- |
8.6, 9.4 & 11.5(Grade) |
- |
500 |
|
- |
3.4(Special Faces) |
- |
500 |
|
- |
3.3(Faces & Arises) |
- |
1000 |
|
- |
3.1(Shape) |
- |
500 |
|
- |
8.1.1(General (Exposed wall construction)) |
- |
500 |
|
- |
5(MA TEIUA.LS) |
- |
44500 |
|
Cement Rs 10000
Flyash Rs 13500
Aggregates Rs 12000
Lime Rs 9000 |
7(SURI'ACE TUTUU AND FINISH) |
- |
1000 |
|
- |
9.3(Thermal Conductivity) |
- |
0 |
|
No test facility at present |
15(Marking) |
- |
500 |
|
- |
8(Physical requirments) |
- |
15000 |
|
- |
8.2(Physical requirments-Dimensions-Length) |
- |
1000 |
|
- |
8.2(Physical requirments-Dimensions-Height) |
- |
1000 |
|
- |
8.2(Physical requirments-Dimensions-Width) |
- |
1000 |
|
- |
8.3(Physical requirments- Block density) |
- |
3000 |
|
- |
8.4(Physical requirments- Compressive strength) |
- |
12000 |
|
- |
8.5(Thermal Conductivity) |
- |
0 |
|
No facility at present |
8.6( Drying Shrinkage ) |
- |
2000 |
|
- |
8.4, 9.2 & 11.3(Indivisual Moisture Content) |
- |
1000 |
|
- |
8.4, 9.2 & 11.3(Indivisual Bulk density) |
- |
1000 |
|
- |
8.4, 9.2 & 11.3 & Table 1(Indivisual Compressive strength) |
- |
1000 |
|
- |
8.3 & 9.1(Indivisual Moisture Content) |
- |
1000 |
|
- |
8.3 & 9.1 Table 1(Indivisual Block Density) |
- |
1000 |
|
- |
3.2 & 8.2(Indivisual Height) |
- |
500 |
|
- |
3.2 & 8.2(Indivisual Width) |
- |
500 |
|
- |
3.2 & 8.2(Indivisual Length) |
- |
500 |
|
- |
8.6, 9.4 & 11.5(Grade) |
- |
500 |
|
- |
3.4(Special Faces) |
- |
500 |
|
- |
3.3(Faces & Arises) |
- |
1000 |
|
- |
3.1(Shape) |
- |
500 |
|
- |
8.1.1(General (Exposed wall construction)) |
- |
500 |
|
- |
5(MA TEIUA.LS) |
- |
44500 |
|
Cement Rs 10000
Flyash Rs 13500
Aggregates Rs 12000
Lime Rs 9000 |
7(SURI'ACE TUTUU AND FINISH) |
- |
1000 |
|
- |
9.3(Thermal Conductivity) |
- |
0 |
|
No test facility at present |
15(Marking) |
- |
500 |
|
- |
8(Physical requirments) |
- |
15000 |
|
- |
8.2(Physical requirments-Dimensions-Length) |
- |
1000 |
|
- |
8.2(Physical requirments-Dimensions-Height) |
- |
1000 |
|
- |
8.2(Physical requirments-Dimensions-Width) |
- |
1000 |
|
- |
8.3(Physical requirments- Block density) |
- |
3000 |
|
- |
8.4(Physical requirments- Compressive strength) |
- |
12000 |
|
- |
8.5(Thermal Conductivity) |
- |
0 |
|
no facility at present |
8.6( Drying Shrinkage ) |
- |
2000 |
|
- |
8.4, 9.2 & 11.3(Indivisual Moisture Content) |
- |
1000 |
|
- |
8.4, 9.2 & 11.3(Indivisual Bulk density) |
- |
1000 |
|
- |
8.4, 9.2 & 11.3 & Table 1(Indivisual Compressive strength) |
- |
1000 |
|
- |
8.3 & 9.1(Indivisual Moisture Content) |
- |
1000 |
|
- |
8.3 & 9.1 Table 1(Indivisual Block Density) |
- |
1000 |
|
- |
3.2 & 8.2(Indivisual Height) |
- |
500 |
|
- |
3.2 & 8.2(Indivisual Width) |
- |
500 |
|
- |
3.2 & 8.2(Indivisual Length) |
- |
500 |
|
- |
8.6, 9.4 & 11.5(Grade) |
- |
500 |
|
- |
3.4(Special Faces) |
- |
500 |
|
- |
3.3(Faces & Arises) |
- |
1000 |
|
- |
3.1(Shape) |
- |
500 |
|
- |
8.1.1(General (Exposed wall construction)) |
- |
500 |
|
- |
5(MA TEIUA.LS) |
- |
44500 |
|
Cement Rs 10000
Flyash Rs 13500
Aggregates Rs 12000
Lime Rs 9000 |
7(SURI'ACE TUTUU AND FINISH) |
- |
1000 |
|
- |
9.3(Thermal Conductivity) |
- |
0 |
|
No facility at present |
15(Marking) |
- |
500 |
|
- |
8(Physical requirments) |
- |
15000 |
|
- |
8.2(Physical requirments-Dimensions-Length) |
- |
1000 |
|
- |
8.2(Physical requirments-Dimensions-Height) |
- |
1000 |
|
- |
8.2(Physical requirments-Dimensions-Width) |
- |
1000 |
|
- |
8.3(Physical requirments- Block density) |
- |
3000 |
|
- |
8.4(Physical requirments- Compressive strength) |
- |
12000 |
|
- |
8.5(Thermal Conductivity) |
- |
0 |
|
No facility at present |
8.6( Drying Shrinkage ) |
- |
2000 |
|
- |
8.4, 9.2 & 11.3(Indivisual Moisture Content) |
- |
1000 |
|
- |
8.4, 9.2 & 11.3(Indivisual Bulk density) |
- |
1000 |
|
- |
8.4, 9.2 & 11.3 & Table 1(Indivisual Compressive strength) |
- |
1000 |
|
- |
8.3 & 9.1(Indivisual Moisture Content) |
- |
1000 |
|
- |
8.3 & 9.1 Table 1(Indivisual Block Density) |
- |
1000 |
|
- |
3.2 & 8.2(Indivisual Height) |
- |
500 |
|
- |
3.2 & 8.2(Indivisual Width) |
- |
500 |
|
- |
3.2 & 8.2(Indivisual Length) |
- |
500 |
|
- |
8.6, 9.4 & 11.5(Grade) |
- |
500 |
|
- |
3.4(Special Faces) |
- |
500 |
|
- |
3.3(Faces & Arises) |
- |
1000 |
|
- |
3.1(Shape) |
- |
500 |
|
- |
8.1.1(General (Exposed wall construction)) |
- |
500 |
|
- |
5(MA TEIUA.LS) |
- |
44500 |
|
Cement Rs 10000
Flyash Rs 13500
Aggregates Rs 12000
Lime Rs 9000 |
7(SURI'ACE TUTUU AND FINISH) |
- |
1000 |
|
- |
9.3(Thermal Conductivity) |
- |
0 |
|
No facility at present |
15(Marking) |
- |
500 |
|
- |
8(Physical requirments) |
- |
15000 |
|
- |
8.2(Physical requirments-Dimensions-Length) |
- |
1000 |
|
- |
8.2(Physical requirments-Dimensions-Height) |
- |
1000 |
|
- |
8.2(Physical requirments-Dimensions-Width) |
- |
1000 |
|
- |
8.3(Physical requirments- Block density) |
- |
3000 |
|
- |
8.4(Physical requirments- Compressive strength) |
- |
12000 |
|
- |
8.5(Thermal Conductivity) |
- |
0 |
|
No facility at present |
8.6( Drying Shrinkage ) |
- |
2000 |
|
- |
8.4, 9.2 & 11.3(Indivisual Moisture Content) |
- |
1000 |
|
- |
8.4, 9.2 & 11.3(Indivisual Bulk density) |
- |
1000 |
|
- |
8.4, 9.2 & 11.3 & Table 1(Indivisual Compressive strength) |
- |
1000 |
|
- |
8.3 & 9.1(Indivisual Moisture Content) |
- |
1000 |
|
- |
8.3 & 9.1 Table 1(Indivisual Block Density) |
- |
1000 |
|
- |
3.2 & 8.2(Indivisual Height) |
- |
500 |
|
- |
3.2 & 8.2(Indivisual Width) |
- |
500 |
|
- |
3.2 & 8.2(Indivisual Length) |
- |
500 |
|
- |
8.6, 9.4 & 11.5(Grade) |
- |
500 |
|
- |
3.4(Special Faces) |
- |
500 |
|
- |
3.3(Faces & Arises) |
- |
1000 |
|
- |
3.1(Shape) |
- |
500 |
|
- |
8.1.1(General (Exposed wall construction)) |
- |
500 |
|
- |
5(MA TEIUA.LS) |
- |
44500 |
|
Cement Rs 10000
Flyash Rs 13500
Aggregates Rs 12000
Lime Rs 9000 |
7(SURI'ACE TUTUU AND FINISH) |
- |
1000 |
|
- |
9.3(Thermal Conductivity) |
- |
0 |
|
No test facility available |
15(Marking) |
- |
500 |
|
- |
8(Physical requirments) |
- |
15000 |
|
- |
8.2(Physical requirments-Dimensions-Length) |
- |
1000 |
|
- |
8.2(Physical requirments-Dimensions-Height) |
- |
1000 |
|
- |
8.2(Physical requirments-Dimensions-Width) |
- |
1000 |
|
- |
8.3(Physical requirments- Block density) |
- |
3000 |
|
- |
8.4(Physical requirments- Compressive strength) |
- |
12000 |
|
- |
8.5(Thermal Conductivity) |
- |
0 |
|
No test facility available at present |
8.6( Drying Shrinkage ) |
- |
2000 |
|
- |
8.4, 9.2 & 11.3(Indivisual Moisture Content) |
- |
1000 |
|
- |
8.4, 9.2 & 11.3(Indivisual Bulk density) |
- |
1000 |
|
- |
8.4, 9.2 & 11.3 & Table 1(Indivisual Compressive strength) |
- |
1000 |
|
- |
8.3 & 9.1(Indivisual Moisture Content) |
- |
1000 |
|
- |
8.3 & 9.1 Table 1(Indivisual Block Density) |
- |
1000 |
|
- |
3.2 & 8.2(Indivisual Height) |
- |
500 |
|
- |
3.2 & 8.2(Indivisual Width) |
- |
500 |
|
- |
3.2 & 8.2(Indivisual Length) |
- |
500 |
|
- |
8.6, 9.4 & 11.5(Grade) |
- |
500 |
|
- |
3.4(Special Faces) |
- |
500 |
|
- |
3.3(Faces & Arises) |
- |
1000 |
|
- |
3.1(Shape) |
- |
500 |
|
- |
8.1.1(General (Exposed wall construction)) |
- |
500 |
|
- |
5(MA TEIUA.LS) |
- |
44500 |
|
Cement Rs 10000
Flyash Rs 13500
Aggregates Rs 12000
Lime Rs 9000 |
7(SURI'ACE TUTUU AND FINISH) |
- |
1000 |
|
- |
9.3(Thermal Conductivity) |
- |
0 |
|
No facility available at present |
15(Marking) |
- |
500 |
|
- |
|
Complete
|
|
- |
- |
10 |
IS/ISO 22702 (2018) |
Utility lighters Safety specifications First Revision |
- |
-
|
20000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(Flame generation) |
- |
500 |
|
- |
4.2(Flame heights) |
- |
900 |
|
- |
4.3(Flame- height adjustment) |
- |
400 |
|
- |
4.4("Resistance to Spitting or
Sputtering and flaring") |
- |
1800 |
|
- |
4.5(Flame extinction) |
- |
1800 |
|
- |
4.6(Volumetric Displacement) |
- |
1800 |
|
- |
5.2(Resistance to dropping) |
- |
1800 |
|
- |
5.3(Resistance to elevated temperature) |
- |
1800 |
|
- |
5.4(Burning behavior) |
- |
900 |
|
- |
5.5(Resistance to continuous burn) |
- |
2000 |
|
- |
5.6(Resistance to cyclic burn) |
- |
1800 |
|
- |
5.7(External Finish) |
- |
0 |
|
- |
5.8(Compatibility with fuel) |
- |
1800 |
|
- |
5.9(Resistance to internal pressure) |
- |
1800 |
|
- |
6(Refilling Test) |
- |
900 |
|
- |
|
Complete
|
|
- |
- |
11 |
IS/ISO 9994 (2018) |
Lighters Safety specifications First Revision |
- |
-
|
20000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.4.2(Flame Height) |
- |
1800 |
|
- |
Cl.4.3(Flame-Height adjustment) |
- |
600 |
|
- |
Cl.4.4(Resistance to spitting or sputtering and flaring) |
- |
900 |
|
- |
Cl.4.5(Flame Extinction) |
- |
1800 |
|
- |
Cl.4.6(Volumetric displacement of Fuel) |
- |
1800 |
|
- |
Cl.4.7(Mass of Fuel) |
- |
600 |
|
- |
Cl.5.1(External Finish) |
- |
800 |
|
- |
Cl.5.2(Compatibility of Fuel) |
- |
1000 |
|
- |
Cl.5.3(Resistance to Fuel Loss) |
- |
600 |
|
- |
Cl.5.4(Resistance to dropping) |
- |
1800 |
|
- |
Cl.5.5(Resistance to elevated Temperature) |
- |
1800 |
|
- |
Cl.5.6(Resistance to internal Pressure) |
- |
1800 |
|
- |
Cl.5.7(Burning Behavior) |
- |
900 |
|
- |
Cl.5.8(Resistance to cyclic burning) |
- |
900 |
|
- |
Cl.5.9(Resistance to Continue Burning) |
- |
2000 |
|
- |
Cl.4(Flame Generation) |
- |
900 |
|
- |
|
Complete
|
|
- |
- |
12 |
IS 12776 (2002) |
Galvanized strand for earthing - Specification (First Revision) |
- |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.2(Freedom From Defects (IS 12776)) |
- |
250 |
|
- |
5.3(Joints in wires (IS 12776)) |
- |
250 |
|
- |
6- Annex-A, Sl-2(Size of the wire (IS 12776)) |
- |
250 |
|
- |
6- Annex-A, Sl-8(Lay (IS 12776)) |
- |
250 |
|
- |
8.1-Annex-A,Sl-9(Breaking Force of Strand (IS 12776)) |
- |
1500 |
|
- |
8.2-Annex-A,Sl-6(Elongation of wire, IS 10810(Part-37)) |
- |
1500 |
|
- |
8.3-Annex-A,Sl-12(Resistance at 200 C (IS 12776)) |
- |
1500 |
|
- |
8.4(Wrapping Test (IS 12776)) |
- |
500 |
|
- |
8.5-Annex-A-Sl-7a(Amount of zinc Coating (IS 6745)) |
- |
1000 |
|
- |
8.5-Annex-A-Sl-7b(Uniformity of Coating (IS 2633)) |
- |
1000 |
|
- |
8.5-Annex-A-Sl-4(Torsion Test IS 10810(Part-37)) |
- |
500 |
|
- |
8.2-Annex-A,Sl-3(Tensile Strength of wire IS 10810(Part-37)) |
- |
1500 |
|
- |
|
Complete
|
|
- |
- |
13 |
IS 9537 : Part 2 (1981) |
Specification for conduits for electrical installations: Part 2 rigid steel conduits |
- |
-
|
8000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.3(Marking, Cl. 6.4 of IS 9537-1) |
- |
1000 |
|
- |
7.2.1(Dimensions, (Minimum outside Diameter), IS 9537-2) |
- |
1000 |
|
- |
7.2.2(Dimensions (Maximum outside Diameter), IS 9537-2) |
- |
1000 |
|
- |
7.3(Dimensions (Wall thickness), IS 9537-2) |
- |
1000 |
|
- |
7.4(Screw threads, IS 9537-2) |
- |
0 |
|
- |
9.2(Mechanical Properties (Bending test), Cl. 9.3 of IS 9537-1) |
- |
1000 |
|
- |
9.3(Mechanical Properties (Compression Test), IS 9537-2) |
- |
2000 |
|
- |
13(External Influences, IS 9537-2) |
- |
2000 |
|
- |
7.4(Screw threads, IS 9537-2) |
- |
1000 |
|
- |
13(External Influences, IS 9537-2) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
14 |
IS 2830 (2012) |
Carbon steel cast billet ingots, billets, blooms and slabs for re-rolling into steel for general structural purposes - Specification (Third Revision) |
- |
-
|
4000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1(Carbon %) |
- |
800 |
|
nil |
6.1(Manganese %) |
- |
800 |
|
nil |
6.1(Phosphorus %) |
- |
800 |
|
nil |
6.1(Sulphur %) |
- |
800 |
|
nil |
6.1( Copper %) |
- |
800 |
|
nil |
6.1(Silicon %) |
- |
800 |
|
- |
|
Complete
|
|
- |
- |
15 |
IS 1786 (2008) |
High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) |
- |
-
|
27000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 8.1(UTM) |
- |
4000 |
|
Rs 4000/- for 32mm, Rs 3000/- for 16mm-28mm, Rs 2000/- for 8mm-12mm. |
Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Sulphur & Phosphorous) |
- |
1180 |
|
INCLUDING 18 % GST |
Cl.4.2 of IS 1786 (Grade:- Fe 415D,Fe 415S, Fe 500D,Fe 500S,Fe 550D)(Carbon Equivalent) |
- |
1180 |
|
INCLUDING 18 % GST |
Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Carbon-IS 228) |
- |
1180 |
|
INCLUDING 18 % GST |
Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Sulphur-IS 228) |
- |
1180 |
|
INCLUDING 18 % GST |
Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Phosphorous- IS 228) |
- |
1180 |
|
INCLUDING 18 % GST |
Cl. 5 (Cl. 5 - Mean projected area of transverse ribs (1/3 of Ar)) |
- |
1000 |
|
- |
Cl. 5.7(Bond Strength at 0.25 mm slip) |
- |
15000 |
|
Rs 10000/- for 8mm- 12mm, Rs 15000 for 16mm- 32mm. |
Cl 7.2(Weight) |
- |
1000 |
|
- |
Cl 8.1(UTM) |
- |
4000 |
|
- |
Cl. 9.3, Table 4(Bend Test ) |
- |
1000 |
|
- |
Cl.9.4 & Cl. 9.4.1(Rebend test) |
- |
1000 |
|
- |
Cl.4.2 of IS 1786 (Vanadium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1180 |
|
INCLUDING 18 % GST |
Cl.4.2 of IS 1786 (Molybdenum- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1180 |
|
INCLUDING 18 % GST |
Cl.4.2 of IS 1786 (Chromium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1180 |
|
INCLUDING 18 % GST |
Cl.4.2 of IS 1786 (Nickel- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1180 |
|
INCLUDING 18 % GST |
Cl.4.2 of IS 1786 (Copper- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1180 |
|
INCLUDING 18 % GST |
Cl.4.2 of IS 1786 (Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1180 |
|
INCLUDING 18 % GST |
|
Complete
|
|
- |
- |
16 |
IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
-
|
22000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3(CONDUCTOR: MATERIALS) |
- |
500 |
|
- |
4(INSULATION : MATERIALS) |
- |
500 |
|
- |
5.1(FILLER AND INNER SHEATH) |
- |
500 |
|
- |
6(ARMOURING) |
- |
500 |
|
- |
7(OUTER SHEATH) |
- |
500 |
|
- |
8.1(CONDUCTOR: CONSTRUCTION) |
- |
500 |
|
- |
8.2(PROTECTIVE BARRIER) |
- |
500 |
|
- |
8.3(SIZE OF NEUTRAL CONDUCTOR) |
- |
500 |
|
- |
9.1(Insulation Applied by extrusicn) |
- |
500 |
|
- |
9.2(Thickness of Insulation - Average) |
- |
500 |
|
- |
9.3(Thickness of Insulation - Minimum) |
- |
500 |
|
- |
9.4(Application of Insulation) |
- |
500 |
|
- |
10.1(Core Identification) |
- |
500 |
|
- |
10.2(Core Identification- Neutral) |
- |
500 |
|
- |
10.3(Core Identification by number ) |
- |
500 |
|
- |
10.4(Core Identification by number - Neutral ) |
- |
500 |
|
- |
11(LAVING UP OF CORES) |
- |
500 |
|
- |
12.1 & 12.2(Inner sheath : Application) |
- |
500 |
|
- |
12.3(Thickness of Inner Sheath) |
- |
500 |
|
- |
13.1(Armouring: Application) |
- |
500 |
|
- |
13.1.2(Armouring: Coverage ) |
- |
500 |
|
- |
13.1.3(Armouring: Direction of Lay ) |
- |
500 |
|
- |
13.2(Type of armour ) |
- |
500 |
|
- |
13.3(Armouring : Dimensions -Wire Diameter) |
- |
500 |
|
- |
13.3(Armouring : Dimensions -Formed wire ) |
- |
500 |
|
- |
13.5(Armouring : Resistance Test) |
- |
1000 |
|
- |
13.6 a)(ARMOURING: Tensile Strength) |
- |
1000 |
|
- |
13.6 b)(ARMOURING: Elongation ) |
- |
1000 |
|
- |
13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
1000 |
|
- |
13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
1000 |
|
- |
13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
1000 |
|
- |
13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
1000 |
|
- |
13.6 g)(ARMOURING: Resistivity) |
- |
1000 |
|
- |
14.1(Outer Sheath : Application) |
- |
1000 |
|
- |
14.2(Colour of outer sheath) |
- |
1000 |
|
- |
14.3(Thickness of outer sheath - AVERAGE) |
- |
1000 |
|
- |
15.1 a) i)(Annealing Test ( For copper wire ) ) |
- |
1000 |
|
- |
15.1 a) ii)(Tensile test (for aluminium) - Before stranding ) |
- |
1000 |
|
- |
15.1 a) ii)(Tensile test (for aluminium) - After stranding ) |
- |
1000 |
|
- |
15.1 a) iii)(Wrapping test (for aluminium)) |
- |
500 |
|
- |
15.1 a) iv)(Resistance test - Main conductor) |
- |
1000 |
|
- |
15.1 a) iv)(Resistance test - Neutral conductor) |
- |
1000 |
|
- |
15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
1000 |
|
- |
15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
1000 |
|
- |
15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
1000 |
|
- |
15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
1000 |
|
- |
15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
1000 |
|
- |
15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
1000 |
|
- |
15.1 d) iv) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
1000 |
|
- |
15.1 d) v) (Insulation: Waterabsorption(gravimetric)) |
- |
1000 |
|
- |
15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
1000 |
|
- |
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
1000 |
|
- |
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
1000 |
|
- |
15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
1000 |
|
- |
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
1000 |
|
- |
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
1000 |
|
- |
15.1 e) v) (Sheath : Hot deformation) |
- |
1000 |
|
- |
15.1 e) vi) (Sheath : Heat shock test) |
- |
1000 |
|
- |
15.1 e) vii) (Sheath : Thermalstability) |
- |
1000 |
|
- |
15.1 f)(INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
1000 |
|
- |
16.2(HIGH VOLTAGE TEST ) |
- |
1000 |
|
- |
16.3(FLAMMABILITY TEST : Period of Burning ) |
- |
500 |
|
- |
16.3(FLAMMABILITY TEST : Unaffected length ) |
- |
500 |
|
- |
16.9(Oxygen Index Test) |
- |
5000 |
|
- |
16.14(Temperature Index) |
- |
5000 |
|
- |
16.1(Flame Retardance Test on Single Cables) |
- |
5000 |
|
- |
16.11(Flame Retardance Test on Bunched Cables) |
- |
5000 |
|
- |
16.13(Test for Halogen Acid Gas Evolution) |
- |
5000 |
|
- |
17.1(Manufacturer'. identification) |
- |
500 |
|
- |
17.2(cable Indentification ) |
- |
500 |
|
- |
17.3(cable Code ) |
- |
500 |
|
- |
15.4 (a)(Cold bend) |
- |
500 |
|
- |
15.4 (b)(Cold impact) |
- |
500 |
|
- |
Cl No. 16.15(Smoke density test) |
- |
5000 |
|
- |
15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
1500 |
|
- |
Table 1(Ageing in air oven - Elongation on Insulation) |
- |
1500 |
|
- |
|
Complete
|
|
- |
- |
17 |
IS 9537 : Part 3 (1983) |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
- |
-
|
4950 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1(Marking) |
- |
200 |
|
- |
6.2(Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
200 |
|
- |
6.3(Standard Mark on Conduit) |
- |
100 |
|
- |
7.1.1(Maximum and minimum outside diameter of socket) |
- |
500 |
|
- |
7.2(Minimum inside diameter of conduit) |
- |
500 |
|
- |
7.1.1 Table-2(Length of Socket end) |
- |
500 |
|
- |
7.4(Unifomity of The wall Thickness) |
- |
500 |
|
- |
8.1(Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
9.2(Bending Test i) At Room Temp ii) At Low Temp (-5 ±2°C)) |
- |
500 |
|
- |
9.3(Compression Test as per caluse 9.3 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
9.4(Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
9.5(Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
10(Resistance to Heat -Ball presure test) |
- |
500 |
|
- |
11(Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
12(Electrical Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
12(Electrical Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
|
Complete
|
|
- |
- |
18 |
IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
- |
-
|
20000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(Conductor - Material) |
- |
1000 |
|
- |
5.1(Insulation) |
- |
500 |
|
- |
5.2(Application ) |
- |
500 |
|
- |
12(CONSTRUCTION Core Identification) |
- |
500 |
|
- |
4.2(Conductor resistance test) |
- |
500 |
|
- |
Table 1 iii) c) 1)(Elongation (Without ageing)) |
- |
500 |
|
- |
Table 1 iii) c) 1)(Tensile strength (Without ageing)) |
- |
500 |
|
- |
Table 1 iii) d) 2)(Loss of mass- Sheath ) |
- |
500 |
|
- |
Table 1 iii) c) 2)(Loss of mass- Insulation ) |
- |
500 |
|
- |
Table 1 iii) c) 3)(Elongation variation) |
- |
500 |
|
- |
Table 1 iii) c) 3)(TS variation) |
- |
500 |
|
- |
Table 1 iii) c) 3)(Elongation (After ageing)) |
- |
500 |
|
- |
Table 1 iii) c) 3)(Tensile strength (After ageing)) |
- |
500 |
|
- |
Table 1 iii) d) 3)(Sheath- Elongation variation) |
- |
500 |
|
- |
Table 1 iii) d) 3)(Sheath- TS variation) |
- |
500 |
|
- |
Table 1 iii) d) 3)(Sheath- Elongation (After ageing)) |
- |
500 |
|
- |
Table 1 iii) d) 3)(Sheath- Tensile strength (After ageing)) |
- |
500 |
|
- |
Table 1 iii) d) 1)(Sheath- Elongation (Without ageing)) |
- |
500 |
|
- |
Table 1 iii) d) 1)(Sheath -Tensile strength (Without ageing)) |
- |
500 |
|
- |
Table 1 iii) d) 7)(Thermal stability- Sheath ) |
- |
500 |
|
- |
Table 1 iii) c) 7)(Thermal stability- Insulation ) |
- |
500 |
|
- |
Table 1 iii) d) 6)(Hot deformation -Indentation depth - Sheath ) |
- |
500 |
|
- |
Table 1 iii) c) 6)(Hot deformation - Indentation depth- Insulation) |
- |
500 |
|
- |
Table 1 iii) c) 4)(Shrinkage-Insulation) |
- |
500 |
|
- |
Table 1 iii) d) 4)(Shrinkage- Sheath ) |
- |
500 |
|
- |
Table 1 iii) d) 5)(Heat shock-Sheath ) |
- |
500 |
|
- |
Table 1 iii) c) 5)(Heat shock-Insulation ) |
- |
500 |
|
- |
10.4(Flammability test- Unaffected portion) |
- |
500 |
|
- |
10.4(Flammability test-Burning after flame removal) |
- |
500 |
|
- |
4.1(Annealing test (for copper)) |
- |
500 |
|
- |
4.1(Wrapping test (for Al)) |
- |
500 |
|
- |
4.1(Tensile test (for Al)- After Stranding) |
- |
500 |
|
- |
4.1(Tensile test (for Al)-Before Stranding) |
- |
500 |
|
- |
10.11(Per sulphate test (for tinned Cu cable only)) |
- |
500 |
|
- |
Table 1 iii) c) 8)(Cold bend for insulation) |
- |
500 |
|
- |
Table 1 iii) d) 8)(Cold bend for sheath) |
- |
500 |
|
- |
Table 1 iii) c) 9)(Cold impact for insulation) |
- |
500 |
|
- |
Table 1 iii) d) 9)(Cold impact for sheath) |
- |
500 |
|
- |
10.9(Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
500 |
|
- |
10.5(Oxygen index) |
- |
5000 |
|
- |
10.7(Temperature index) |
- |
5000 |
|
- |
10.6(Halogen evolution) |
- |
5000 |
|
- |
10.8(Smoke density rating) |
- |
5000 |
|
- |
table 1 e) 3) (IR constant- max. Temp) |
- |
500 |
|
- |
table 1 e) 3) (IR constant- Room temp ) |
- |
500 |
|
- |
table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
500 |
|
- |
table 1 e) 3) (Volume Resistivity - Room temp ) |
- |
500 |
|
- |
10.1(HV (water immersion)) |
- |
1000 |
|
- |
10.1(HV (water immersion)) |
- |
1000 |
|
- |
10.2(HV (room temperature)) |
- |
1000 |
|
- |
9(Overall dimensions) |
- |
500 |
|
- |
8.3(Minimum thickness of Sheath) |
- |
500 |
|
- |
8.3(Avarage thickness of Sheath) |
- |
500 |
|
- |
5.3(Minimum thickness of insulation) |
- |
500 |
|
- |
5.3(Avarage thickness of insulation) |
- |
500 |
|
- |
Table 4(Copper purity test) |
- |
2000 |
|
- |
|
Complete
|
|
- |
- |
19 |
IS 513 : Part 2 (2016) |
Cold reduced carbon steel sheet and strip: Part 2 high tensile and multi - Phase steel (Sixth Revision) |
- |
-
|
8500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 9(Workmanship) |
- |
1000 |
|
- |
Cl 7(UTM) |
- |
3000 |
|
- |
Cl. 7.2 Table 7(Bend Test) |
- |
1000 |
|
- |
Cl 10(Length, Width & Thickness) |
- |
1000 |
|
- |
Cl. 7.3 Table 4A & 4B(Tensile Strain Hardening) |
- |
3000 |
|
Additional Charges |
Cl. 8.5.3 Table 6(Surface Roughness) |
- |
1000 |
|
Additional Charges |
|
Complete
|
|
- |
- |
20 |
IS 277 (2018) |
Galvanized steel strips and sheets (Plain And Corrugated) - Specification (Seventh Revision) |
- |
-
|
5000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 8.1(UTM) |
- |
3000 |
|
- |
Cl 8.2(Press) |
- |
1000 |
|
- |
Cl 14(Length, Width & Thickness) |
- |
1000 |
|
- |
7.1 & 10.2(Mass of Coating: Single Spot Test) |
- |
1000 |
|
- |
7.1 & 10.2(Mass of Coating: Triple Spot Test) |
- |
1000 |
|
- |
|
Complete
|
|
- |
- |
21 |
IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
Earthed & Unearthed upto 1.1kV and DC upto 1.5kV |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(MATERIALS : CONDUCTOR) |
- |
1000 |
|
- |
4.1.1(INSULATION : General Purjose Insulaiion) |
- |
500 |
|
- |
4.1.2(INSULATION : Heat Resisting Insulation) |
- |
500 |
|
- |
5.1(MATERIALS : FILLER AND INNER SHEATH) |
- |
500 |
|
- |
5.2(MATERIALS : FILLER AND INNER SHEATH) |
- |
500 |
|
- |
8.1(CONSTRUCTION : CONDUCTOR) |
- |
500 |
|
- |
8.2(CONSTRUCTION : CONDUCTOR) |
- |
500 |
|
- |
9.2(INSULATION : Thickness of Insulation) |
- |
500 |
|
- |
9.3(INSULATION :Tolerance on Thickness of Insulation) |
- |
500 |
|
- |
9.4(INSULATION : Application of Insulation) |
- |
500 |
|
- |
10.1(CORE IDENTIFICATION) |
- |
500 |
|
- |
10.2(CORE IDENTIFICATION) |
- |
500 |
|
- |
10.3(CORE IDENTIFICATION) |
- |
500 |
|
- |
11.1(LAYING UP OF CORES) |
- |
500 |
|
- |
11.2(LAYING UP OF CORES) |
- |
500 |
|
- |
12.1(INNER SHEATH) |
- |
500 |
|
- |
12.2(INNER SHEATH) |
- |
500 |
|
- |
12.3(INNER SHEATH :Thickness of Inner Sheath) |
- |
500 |
|
- |
12.3.1(INNER SHEATH :Thickness of Inner Sheath) |
- |
500 |
|
- |
13.1.1(ARMOURING : Application) |
- |
500 |
|
- |
13.1.2(Armouring: Coverage ) |
- |
500 |
|
- |
13.3(Armouring : Dimensions -Wire Diameter) |
- |
1000 |
|
- |
13.4(ARMOURING : Joints) |
- |
1000 |
|
- |
13.5.1(ARMOURING : Resistance) |
- |
1000 |
|
- |
13.5.2(ARMOURING : Resistance) |
- |
1000 |
|
- |
13.6 a)(ARMOURING: Tensile Strength) |
- |
1000 |
|
- |
13.6 b)(ARMOURING: Elongation ) |
- |
1000 |
|
- |
13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
1000 |
|
- |
13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
1000 |
|
- |
13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
1000 |
|
- |
13.6 g)(ARMOURING: Resistivity) |
- |
1000 |
|
- |
14.1(OUTER SHEATH) |
- |
1000 |
|
- |
14.3(OUTER SHEATH : Colour ) |
- |
1000 |
|
- |
14.4.1(Thickness of Outer Sheath : Unarmowed Cables) |
- |
1000 |
|
- |
14.4.2(Thickness of Outer Sheath : Armoured Cables) |
- |
1000 |
|
- |
15.1 a) 1)(Tests on conductor : Annealing test ( for copper )) |
- |
1000 |
|
- |
15.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
1000 |
|
- |
15.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
1000 |
|
- |
15.1 a) 3)(Tests on conductor : Wrapping test ( for aluminium )) |
- |
1000 |
|
- |
15.1 a) 4)(Tests on conductor : Conductor resistance test) |
- |
1000 |
|
- |
15.1 a) 4)(Resistance test - Neutral conductor ) |
- |
1000 |
|
- |
15.1 d)1)(Phyaical tests for insulation : Tensile Test) |
- |
1000 |
|
- |
15.1 d)1)(Phyaical tests for insulation : Elongation ) |
- |
1000 |
|
- |
15.1 d)2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
1000 |
|
- |
15.1 d)2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
1000 |
|
- |
15.1 d)2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
1000 |
|
- |
15.1 d)2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
1000 |
|
- |
15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
1000 |
|
- |
15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
1000 |
|
- |
15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
1000 |
|
- |
15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
1000 |
|
- |
15.1 d)3)(Phyaical tests for Sheath : Shrinkage ) |
- |
1000 |
|
- |
15.1 d)4)(Hot deformation : Insulation ) |
- |
1000 |
|
- |
15.1 d)4)(Hot deformation : Sheath ) |
- |
1000 |
|
- |
15.1 d)5)( Loss of mass in air oven- Insulation ) |
- |
1000 |
|
- |
15.1 d)5)( Loss of mass in air oven- sheath ) |
- |
1000 |
|
- |
15.1 d)6)(Heat shock test- Insulation ) |
- |
1000 |
|
- |
15.1 d)7)(Thermal stability- insulation ) |
- |
1000 |
|
- |
15.1 d)7)(Thermal stability- Sheath ) |
- |
1000 |
|
- |
15.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
1000 |
|
- |
15.1 e)(Insulation resistance test : IR Constant ) |
- |
1000 |
|
- |
15.1 f)(High voltage test ( water immersion test )) |
- |
1000 |
|
- |
15.1 g)(High voltage test at room temperature) |
- |
1000 |
|
- |
15.4 a)(Cold bend test- Insulation ( Optional test)) |
- |
1000 |
|
- |
15.4 a)(Cold bend test- Sheath ( Optional test)) |
- |
1000 |
|
- |
15.4 b)(Cold impact test- Sheath ( Optional test)) |
- |
1000 |
|
- |
15.4 b)(Cold impact test- Insulation ( Optional test)) |
- |
1000 |
|
- |
16.2(DETAILS OF TESTS : High Voltage Test at Room Temperature) |
- |
1000 |
|
- |
16.3.1(High Voltage Test ( Water Immersion Test ) : a.c. Test) |
- |
1000 |
|
- |
16.3.2(High Voltage Test ( Water Immersion Test ) : d.c. Test) |
- |
1000 |
|
- |
16.4(Flammability Test) |
- |
1000 |
|
- |
16.5(Oxygen Index Test) |
- |
5000 |
|
- |
16.6(Flame Retardance Test on Single Cables) |
- |
1000 |
|
- |
16.9(Test for Halogen Acid Gas Evolution) |
- |
5000 |
|
- |
16.1(Temperature Index) |
- |
5000 |
|
- |
Cl No. 16.10(Smoke density test) |
- |
5000 |
|
- |
Table 4(Copper purity test) |
- |
1000 |
|
- |
16.4(Flammability Test- Un affected portion) |
- |
1000 |
|
- |
15.1.e(Insulation resistance Test- Volume Resistivity At Room temperature) |
- |
1000 |
|
- |
|
Complete
|
|
- |
- |
22 |
IS 1786 (2008) |
High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) |
- |
-
|
221.49.60 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 8.1(UTM) |
Nitrogen exclusion |
4000 |
|
Rs 4000/- for 32mm, Rs 3000/- for 16mm-28mm, Rs 2000/- for 8mm-12mm. |
Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Sulphur & Phosphorous) |
Nitrogen exclusion |
1180 |
|
INCLUDING 18 % GST |
Cl.4.2 of IS 1786 (Grade:- Fe 415D,Fe 415S, Fe 500D,Fe 500S,Fe 550D)(Carbon Equivalent) |
Nitrogen exclusion |
1180 |
|
INCLUDING 18 % GST |
Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Carbon-IS 228) |
Nitrogen exclusion |
1180 |
|
INCLUDING 18 % GST |
Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Sulphur-IS 228) |
Nitrogen exclusion |
1180 |
|
INCLUDING 18 % GST |
Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Phosphorous- IS 228) |
Nitrogen exclusion |
1180 |
|
INCLUDING 18 % GST |
Cl. 5 (Cl. 5 - Mean projected area of transverse ribs (1/3 of Ar)) |
Nitrogen exclusion |
1000 |
|
- |
Cl. 5.7(Bond Strength at 0.25 mm slip) |
Nitrogen exclusion |
15000 |
|
Rs 10000/- for 8mm- 12mm, Rs 15000 for 16mm- 32mm. |
Cl 7.2(Weight) |
Nitrogen exclusion |
1000 |
|
- |
Cl 8.1(UTM) |
Nitrogen exclusion |
4000 |
|
- |
Cl. 9.3, Table 4(Bend Test ) |
Nitrogen exclusion |
1000 |
|
- |
Cl.9.4 & Cl. 9.4.1(Rebend test) |
Nitrogen exclusion |
1000 |
|
- |
|
Complete
|
|
- |
- |
23 |
IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
- |
-
|
20000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(Conductor - Material) |
- |
1000 |
|
- |
5.1(Insulation) |
- |
500 |
|
- |
5.2(Application ) |
- |
500 |
|
- |
12(CONSTRUCTION Core Identification) |
- |
500 |
|
- |
4.2(Conductor resistance test) |
- |
500 |
|
- |
Table 1 iii) c) 1)(Elongation (Without ageing)) |
- |
500 |
|
- |
Table 1 iii) c) 1)(Tensile strength (Without ageing)) |
- |
500 |
|
- |
Table 1 iii) d) 2)(Loss of mass- Sheath ) |
- |
500 |
|
- |
Table 1 iii) c) 2)(Loss of mass- Insulation ) |
- |
500 |
|
- |
Table 1 iii) c) 3)(Elongation variation) |
- |
500 |
|
- |
Table 1 iii) c) 3)(TS variation) |
- |
500 |
|
- |
Table 1 iii) c) 3)(Elongation (After ageing)) |
- |
500 |
|
- |
Table 1 iii) c) 3)(Tensile strength (After ageing)) |
- |
500 |
|
- |
Table 1 iii) d) 3)(Sheath- Elongation variation) |
- |
500 |
|
- |
Table 1 iii) d) 3)(Sheath- TS variation) |
- |
500 |
|
- |
Table 1 iii) d) 3)(Sheath- Elongation (After ageing)) |
- |
500 |
|
- |
Table 1 iii) d) 3)(Sheath- Tensile strength (After ageing)) |
- |
500 |
|
- |
Table 1 iii) d) 1)(Sheath- Elongation (Without ageing)) |
- |
500 |
|
- |
Table 1 iii) d) 1)(Sheath -Tensile strength (Without ageing)) |
- |
500 |
|
- |
Table 1 iii) d) 7)(Thermal stability- Sheath ) |
- |
500 |
|
- |
Table 1 iii) c) 7)(Thermal stability- Insulation ) |
- |
500 |
|
- |
Table 1 iii) d) 6)(Hot deformation -Indentation depth - Sheath ) |
- |
500 |
|
- |
Table 1 iii) c) 6)(Hot deformation - Indentation depth- Insulation) |
- |
500 |
|
- |
Table 1 iii) c) 4)(Shrinkage-Insulation) |
- |
500 |
|
- |
Table 1 iii) d) 4)(Shrinkage- Sheath ) |
- |
500 |
|
- |
Table 1 iii) d) 5)(Heat shock-Sheath ) |
- |
500 |
|
- |
Table 1 iii) c) 5)(Heat shock-Insulation ) |
- |
500 |
|
- |
10.4(Flammability test- Unaffected portion) |
- |
500 |
|
- |
10.4(Flammability test-Burning after flame removal) |
- |
500 |
|
- |
4.1(Annealing test (for copper)) |
- |
500 |
|
- |
4.1(Wrapping test (for Al)) |
- |
500 |
|
- |
4.1(Tensile test (for Al)- After Stranding) |
- |
500 |
|
- |
4.1(Tensile test (for Al)-Before Stranding) |
- |
500 |
|
- |
10.11(Per sulphate test (for tinned Cu cable only)) |
- |
500 |
|
- |
Table 1 iii) c) 8)(Cold bend for insulation) |
- |
500 |
|
- |
Table 1 iii) d) 8)(Cold bend for sheath) |
- |
500 |
|
- |
Table 1 iii) c) 9)(Cold impact for insulation) |
- |
500 |
|
- |
Table 1 iii) d) 9)(Cold impact for sheath) |
- |
500 |
|
- |
10.9(Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
500 |
|
- |
10.5(Oxygen index) |
- |
5000 |
|
- |
10.7(Temperature index) |
- |
5000 |
|
- |
10.6(Halogen evolution) |
- |
5000 |
|
- |
10.8(Smoke density rating) |
- |
5000 |
|
- |
table 1 e) 3) (IR constant- max. Temp) |
- |
500 |
|
- |
table 1 e) 3) (IR constant- Room temp ) |
- |
500 |
|
- |
table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
500 |
|
- |
table 1 e) 3) (Volume Resistivity - Room temp ) |
- |
500 |
|
- |
10.1(HV (water immersion)) |
- |
1000 |
|
- |
10.1(HV (water immersion)) |
- |
1000 |
|
- |
10.2(HV (room temperature)) |
- |
1000 |
|
- |
9(Overall dimensions) |
- |
500 |
|
- |
8.3(Minimum thickness of Sheath) |
- |
500 |
|
- |
8.3(Avarage thickness of Sheath) |
- |
500 |
|
- |
5.3(Minimum thickness of insulation) |
- |
500 |
|
- |
5.3(Avarage thickness of insulation) |
- |
500 |
|
- |
|
Complete
|
|
- |
- |
24 |
IS 2062 (2011) |
Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) |
- |
-
|
13000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 10.3(UTM) |
- |
3000 |
|
- |
Cl 11.3(Press) |
- |
1000 |
|
- |
Cl 12(Sudden Load Applied) |
- |
0 |
|
NA |
Cl 15(Length, Width & Thickness) |
- |
1000 |
|
- |
Cl 11.3(Press) |
- |
1000 |
|
- |
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Carbon Equivalent- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Copper- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Nickel- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Chromium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Molybdenum- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Vanadium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
|
Complete
|
|
- |
- |
25 |
IS 269 (2015) |
Ordinary portland cement - Specification (Sixth Revision) |
- |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7 Table-3 iv c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
7 Table-3 iv b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
7 Table-3 iv a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
7 Table-3 iii b(Setting Time Final) |
- |
590 |
|
ALL FEES ARE INCLUDING GST |
7 Table-3 iii a(Setting Time Initial) |
- |
590 |
|
ALL FEES ARE INCLUDING GST |
7 Table-3 ii b(Expansion by Autoclave) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
7 Table-3 ii a(Expansion by Le Chatelier) |
- |
590 |
|
ALL FEES ARE INCLUDING GST |
7 Table-3 i.(Fineness) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
6.1 Table-2 i.(Ratio of percentage of lime to percentage of silica, alumina and iron oxide) |
- |
0 |
|
- |
6.1 Table-2 ii.(Ratio of percentage of alumina to that of iron oxide) |
- |
0 |
|
- |
6.1 Table-2 iii.(Insoluble residue) |
- |
0 |
|
- |
6 - Table - 1 iv(Magnesia - Cl 4.8 of IS 4032:1985) |
- |
0 |
|
- |
6.1 Table-2 v(Total Sulphur Content calculated as Sulphuric Anhydride) |
- |
0 |
|
- |
6.1 Table-2 vi(Loss on ignition) |
- |
0 |
|
- |
6.1 Table-2 vii(Chloride content) |
- |
0 |
|
- |
6.1 Table-2 viii(Alkali content) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
26 |
IS 455 (2015) |
Portland slag cement - Specification |
- |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7 Table 1 iv c(Compretsive Strenqth 672 ± 4 hr
IS 4031(Part 6)) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
7 Table 1 iv b(Compretsive Strenqth 168 ± 2 hr
IS 4031(Part 6)) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
7 Table 1 iv a(Compretsive Strenqth .72 ± 1 hr
IS 4031(Part 6)) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
7 Table 1 iii b(Setting Time ( by Vicat Apparatus ), Final
IS 4031(Part 5)) |
- |
590 |
|
ALL FEES ARE INCLUDING GST |
7 Table 1 iii a(Setting Time ( by Vicat Apparatus ),Initial
IS 4031(Part 5)) |
- |
590 |
|
ALL FEES ARE INCLUDING GST |
7 Table 1 ii b(Soundness, Autoclave expansion
IS 4031(Part 3) ) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
7 Table 1 ii a(Soundness, Le-Chate1ier expansion
IS 4031(Part 3) ) |
- |
590 |
|
ALL FEES ARE INCLUDING GST |
7 Table 1 i(Fineness
IS 4031(Part 2)) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
6 - Table - 1 i(Insoluble residue - Cl 6.9 of IS 4032:1985) |
- |
0 |
|
- |
6 - Table - 1 ii(Magnesia - Cl 6.8 of IS 4032:1985) |
- |
0 |
|
- |
6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 6.11 of IS 4032:1985) |
- |
0 |
|
- |
6 - Table - 1 iv(Sulphide sulphur (S) - Cl 6.12 of IS 4032:1985) |
- |
0 |
|
- |
6 - Table - 1 v(Loss on ignition - Cl 6.2 of IS 4032:1985) |
- |
0 |
|
- |
6 - Table - 1 vi(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
0 |
|
- |
6 - Table - 1 vii( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
27 |
IS 1489 (Part 1) (2015) |
Portland pozzolana cement - Specification: Part 1 fly Ash Based |
- |
-
|
5900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 - Table - 1 i(Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
1180 |
|
ALL FEES ARE INCLUDING GST |
6 - Table - 1 ii(Magnesia - Cl 7.2 of IS 4032:1985) |
- |
1180 |
|
ALL FEES ARE INCLUDING GST |
6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
1180 |
|
ALL FEES ARE INCLUDING GST |
6 - Table - 1 iv(Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
1180 |
|
ALL FEES ARE INCLUDING GST |
6 - Table - 1 v(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
1180 |
|
ALL FEES ARE INCLUDING GST |
6 - Table - 1 vi( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
1180 |
|
ALL FEES ARE INCLUDING GST |
7 -Table 2- vi(Drying Shrinkage- IS 4031 Part 10) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
7 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
7 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
7 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
7 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
590 |
|
ALL FEES ARE INCLUDING GST |
7 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
590 |
|
ALL FEES ARE INCLUDING GST |
7 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
1118 |
|
- |
7 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
590 |
|
ALL FEES ARE INCLUDING GST |
7 -Table 2- i(Fineness 4031 Part 2) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
|
Complete
|
|
- |
- |
28 |
IS 513 : Part 1 (2016) |
Cold reduced carbon steel sheet and strip: Part 1 cold forming and drawing purpose (Sixth Revision) |
- |
-
|
10500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Chemical Composition) |
- |
2500 |
|
Rs 4000/- with micro elements, Rs 2500/- without micro elements. |
8(Mechanical and Physical Properties) |
- |
4000 |
|
(i) Cl. 8.1, Tensile Test, Rs 3000, (iI) Cl. 8.4, Bend Test, Rs 1000 |
Cl 9(Workmanship) |
- |
4000 |
|
Additional charges (i) Cl. 9.3, Strain Ageing, Test Fee, Rs 3000.00, (ii) Cl. 9.5, Surface Finish, Test Fee, Rs 1000.00 |
Cl 9(Workmanship) |
- |
4000 |
|
Additional charges (i) Cl. 9.3, Strain Ageing, Test Fee, Rs 3000.00, (ii) Cl. 9.5, Surface Finish, Test Fee, Rs 1000.00 |
Cl 11(Length, Width & Thickness) |
- |
1000 |
|
Thickness measurement, mm. |
Cl 9.5(Workmanship) |
- |
1000 |
|
Cl. 9.5, Surface Finish, Test Fee, Rs 1000.00 |
Cl 8(UTM) |
- |
3000 |
|
(i) Cl. 8.1, Tensile Test, Rs 3000 |
Cl 11(Length, Width & Thickness) |
- |
1000 |
|
Thickness measurement, mm. |
Cl. 8.3 Table 6(Hardness Test
( Only for CR0 & CR1)) |
- |
2000 |
|
Included in complete test charges. |
Cl 11(Length, Width & Thickness) |
- |
1000 |
|
Included in complete test charges. |
Cl. 8.2(Cupping Test(Only for sheet and coils CR2, CR3, CR4(having thickness 0.5 mm-2.0 mm)) |
- |
3000 |
|
Additional charges not included in complete test charges. |
Cl. 8.5
Table 5A, 5B & 5C(Plastic Strain Ratio
(r bar/r-90)) |
- |
3000 |
|
Additional charges not included in complete test charges. |
Cl. 8.6
Table 5A, 5B & 5C(Tensile Strain Hardening Component
(n-Value)) |
- |
3000 |
|
Additional charges not included in complete test charges. |
Cl. 8.7(Bake Hardening Index) |
- |
3000 |
|
Additional charges not included in complete test charges. |
Cl 10(Workmanship) |
- |
1000 |
|
- |
Cl. 9 Table 8(Surface roughness) |
- |
1000 |
|
- |
|
Complete
|
|
- |
- |
29 |
IS 814 (2004) |
Covered electrodes for manual metal arc welding of carbon and carbon manganese steel - Specification (Sixth Revision) |
- |
-
|
40000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 & 8.2(Carbon- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
4000 |
|
- |
6 & 8.2(Silicon- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
0 |
|
All elements test charges included in carbon |
6 & 8.2(Manganese- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
0 |
|
All elements test charges included in carbon |
6 & 8.2(Phosphorous- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
0 |
|
All elements test charges included in carbon |
6 & 8.2(Sulphur- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
0 |
|
All elements test charges included in carbon |
6 & 8.2(Copper- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
0 |
|
All elements test charges included in carbon |
6 & 8.2(Vanadium- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
0 |
|
All elements test charges included in carbon |
6 & 8.2(Chromium- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
0 |
|
All elements test charges included in carbon |
6 & 8.2(Nickel- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
0 |
|
All elements test charges included in carbon |
6 & 8.2(Molybdenum- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
0 |
|
All elements test charges included in carbon |
6 & 8.2(Mn+Ni+Cr+Mo+V - Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
0 |
|
All elements test charges included in carbon |
7.1.1(Diameter of Core Wire) |
- |
0 |
|
Included in Tensile Test charges |
7.1.2(Length of Electrodes) |
- |
0 |
|
Included in Tensile Test charges |
7.2.1(Contact End) |
- |
0 |
|
Included in Tensile Test charges |
7.2.2(Arc striking End) |
- |
0 |
|
Included in Tensile Test charges |
7.3(Concentricity of Flux covering with core wire) |
- |
0 |
|
Included in Tensile Test charges |
7.4(Defects of Core wire and Coverings) |
- |
0 |
|
Included in Tensile Test charges |
9.1.2 Table 6 (Ultimate Tensile Strength-Annex F) |
- |
0 |
|
13000 |
9.1.2 Table 6 ( Yield Stress -Annex F) |
- |
0 |
|
Included in Tensile Test charges |
9.1.2 Table 6 (Percentage Elongation on Gauge Length-Annex F) |
- |
0 |
|
Included in Tensile Test charges |
9.1.3 Table 6 ( Impact Strength-Annex F) |
- |
0 |
|
Included in Tensile Test charges |
9.2(Butt Weld Bend Test-IS 1599) |
- |
8000 |
|
- |
9.3(Running PerformanceTest-Annex H) |
- |
2000 |
|
- |
9.4(Increased Metal Recovery Test-IS 13043) |
- |
3000 |
|
- |
9.5(Diffusible Hydrogen Evaluation Test-IS 11802) |
- |
5000 |
|
- |
9.6(Radiographic Test- IS 1182) |
- |
1000 |
|
- |
|
Complete
|
|
- |
- |
30 |
IS 15652 (2006) |
Insulating mats for electrical purposes - Specification |
- |
-
|
20000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9(Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
100 |
|
- |
9(Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
100 |
|
- |
9(Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
100 |
|
- |
9(Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
100 |
|
- |
9(Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
100 |
|
- |
9(Marking (As per Cl.9.2 of IS 15652 : 2006)) |
- |
100 |
|
- |
10.a)(Packing) |
- |
300 |
|
- |
10.b)(Packing) |
- |
0 |
|
- |
10.c)(Packing) |
- |
0 |
|
- |
4(Classification and Designation (As per Cl.4.1 and Table-1 of IS 15652 : 2006)) |
- |
100 |
|
- |
4(Classification and Designation (As per Cl.4.1 and Table-1 of IS 15652 : 2006)) |
- |
100 |
|
- |
4(Classification and Designation (As per Cl.4.1 and Table-1 of IS 15652 : 2006)) |
- |
100 |
|
- |
4(Classification and Designation (As per Cl.4.2 of IS 15652 : 2006)) |
- |
100 |
|
- |
4(Classification and Designation (As per Cl.4.2 of IS 15652 : 2006)) |
- |
100 |
|
- |
4(Classification and Designation (As per Cl.4.2 of IS 15652 : 2006)) |
- |
100 |
|
- |
4(Classification and Designation (As per Cl.4.2 of IS 15652 : 2006)) |
- |
100 |
|
- |
5(Composition (As per Cl. 5.1 of IS 15652 : 2006)) |
- |
100 |
|
- |
5(Composition (As per Cl. 5.2 of IS 15652 : 2006)) |
- |
100 |
|
- |
6(Shape Requirements and Dimension (As per Cl.6.1 & 6.2 of IS 15652 : 2006)) |
- |
100 |
|
- |
6(Shape Requirements and Dimension (As per Cl.6.1 & 6.2 of IS 15652 : 2006)) |
- |
500 |
|
- |
6(Thickness [mm] (As per Cl. 6.3 and Table-2 of IS 15652 : 2006)) |
- |
1000 |
|
- |
6(Thickness [mm] (As per Cl. 6.3 and Table-2 of IS 15652 : 2006)) |
- |
0 |
|
- |
6(Thickness [mm] (As per Cl. 6.3 and Table-2 of IS 15652 : 2006)) |
- |
0 |
|
- |
6(Colour (As per Cl. 6.4 of IS 15652 : 2006)) |
- |
100 |
|
- |
7(Workmanship & Finish (As per Cl. 7.1 of IS 15652 : 2006)) |
- |
100 |
|
- |
8(Physical properties (As per Cl.8.1 and Table - 3 of IS 15652 : 2006)) |
- |
500 |
|
- |
8(Physical properties (As per Cl.8.1 and Table - 3 of IS 15652 : 2006)) |
- |
500 |
|
- |
8(Physical properties (As per Cl.8.3 of IS 15652 : 2006)) |
- |
500 |
|
- |
8(Physical properties (As per Cl.8.3 of IS 15652 : 2006)) |
- |
500 |
|
- |
8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
500 |
|
- |
8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
500 |
|
- |
8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
500 |
|
- |
8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
500 |
|
- |
8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
500 |
|
- |
8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
500 |
|
- |
8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
500 |
|
- |
8(Di-electric Properties (As per Cl.8.2.1 and C-3.1 of IS 15652 : 2006)) |
- |
500 |
|
- |
8(Di-electric Properties (As per Cl.8.2.2 and C-3.2 of IS 15652 : 2006)) |
- |
500 |
|
- |
8(Di-electric Properties (As per Cl.8.2.3 and C-3.3 of IS 15652 : 2006)) |
- |
500 |
|
- |
8(Di-electric Properties (Cl.8.2), A.C. Proof Voltage (Cl.8.2.4), C-3.4 and Table-5 of IS 15652 : 2006)) |
- |
500 |
|
- |
8(Thermal Properties (Cl..8.4)) |
- |
500 |
|
- |
8(Thermal Properties (Cl..8.4)) |
- |
500 |
|
- |
8(A.C. Proof Voltage (Cl.8.2.4), C-3.4 and Table-5 of IS 15652 : 2006)) |
- |
500 |
|
- |
8(Extreme Low Temperature (Cl.8.6)) |
- |
500 |
|
- |
8(A.C. Proof Voltage (Cl.8.2.4), C-3.4 and Table-5 of IS 15652 : 2006)) |
- |
500 |
|
- |
8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
- |
|
- |
8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
- |
|
- |
|
Complete
|
|
- |
- |