| 31 |
IS 733 (1983) |
Specification for wrought aluminium and aluminium alloy bars, rods and sections (For General Engineering Purposes) (Third Revision) |
All Grade as per Specification |
11500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Dimension - IS 3965) |
- |
1000 |
|
- |
| Cl. 5.1, Table 2(Tensile Strength- IS 1816) |
- |
2000 |
|
- |
| Cl. 5.1, Table 2(0.2 Percent proof stress- IS 1816) |
- |
2000 |
|
- |
| Cl. 5.1, Table 2(Elongation on 50 mm or 5.65√So Gauge Length) |
- |
1000 |
|
- |
| Cl. 4(Freedom from Defects) |
- |
1000 |
|
- |
| Cl. 0.4, 5.1, Table 1(Copper- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Magnesium- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Silicon- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Iron- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Cr+ Mn- IS 504 or by any other suitable instrumental method) |
- |
1000 |
|
- |
| Cl. 0.4, 5.1, Table 1(Zinc- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Titanium and / or other grain refining elements - IS 504 or by any other suitable instrumental method) |
- |
1000 |
|
- |
|
14 Jun, 2027 |
- - |
| 32 |
IS 733 (2025) |
Wrought Aluminium and Aluminium Alloy Bars, Rods, Sections, Extruded Tube, Hollow Sections and Profiles for General Engineering Purposes ? Specification (Fourth Revision) |
- |
12500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6 Table 1 - Table 8(Zirconium +Titanium) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Fe) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Cu) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Mn) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Mg) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Cr) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Zn) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Ti) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(V) |
- |
500 |
|
- |
| Cl-7.1, 7.2 & 7.3, Table-9(Dimensions) |
- |
1000 |
|
- |
| Cl-7.1, 7.2 & 7.3, Table-9(Rm MPa) |
- |
2000 |
|
- |
| Cl-7.1, 7.2 & 7.3, Table-9(Rp0.2 MPa) |
- |
2000 |
|
- |
| Cl-7.1, 7.2 & 7.3, Table-9(Elongation , Percent) |
- |
1000 |
|
- |
| Cl-9(Dimensions and Tolerances) |
- |
0 |
|
- |
| Cl-12(Packaging and Marking) |
- |
0 |
|
- |
| Cl-7.1(Tensile test) |
- |
0 |
|
- |
| Cl-5(Freedom from Defects) |
- |
1000 |
|
- |
| Cl-6.1, Table-1 to 8(Si) |
- |
500 |
|
- |
| Cl-4(General requirements) |
- |
0 |
|
- |
| Cl-6.1, Table-1 to 8(Aluminium) |
- |
500 |
|
- |
| Cl-6.2(chemical analysis) |
- |
0 |
|
- |
|
14 Jun, 2027 |
- - |
| 33 |
IS 738 (1994) |
Wrought aluminium alloys, drawn tube for general engineering purposes - Specification (Third Revision) |
All Grade |
11500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.7, IS 2678(Wall Thickness at any point) |
- |
500 |
|
- |
| Cl.7, IS 2678(Mean Wall Thickness) |
- |
500 |
|
- |
| Cl. 9.1 Table 2(Tensile Strength- IS 2657) |
- |
2000 |
|
- |
| Cl. 9.1 Table 2(0.2 percent proof stress- IS 2657) |
- |
2000 |
|
- |
| Cl. 9.1 Table 2(Elongation on guage length of 50 mm) |
- |
1000 |
|
- |
| Cl. 6(Freedom from Defects- Cl.6) |
- |
1000 |
|
- |
| Cl. 8.1, Table 1(Aluminium- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
500 |
|
- |
| Cl. 8.1, Table 1(Copper- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
500 |
|
- |
| Cl. 8.1, Table 1(Magnesium- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
500 |
|
- |
| Cl. 8.1, Table 1(Silicon- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
500 |
|
- |
| Cl. 8.1, Table 1(Iron- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
500 |
|
- |
| Cl. 8.1, Table 1(Manganese- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
500 |
|
- |
| Cl. 8.1, Table 1(Zinc- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
500 |
|
- |
| Cl. 8.1, Table 1(Titanium- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
500 |
|
- |
| Cl. 8.1, Table 1(Chromium- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 34 |
IS 303 (2024) |
Plywood for General Purposes â Specification (Fourth Revision) |
- |
13000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.2, Table-2(Maximum Number of Categories of Permissible Defects, per m2) |
- |
500 |
|
- |
| Cl-8.1(Dimensions -length) |
- |
1000 |
|
- |
| Cl-8.2(Thickness of the plywood boards) |
- |
500 |
|
- |
| Cl-8.3(Squareness) |
- |
1000 |
|
- |
| Cl-11.3.1, 11.3.1.1(Water Resistance Test) |
- |
2000 |
|
- |
| Cl-11.3.2(Mycological Test) |
- |
1500 |
|
- |
| Cl-11.4(Moisture Content) |
- |
1000 |
|
- |
| Cl-11.5, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
2000 |
|
- |
| Cl-11.5, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
2000 |
|
- |
| Cl-5.1(Classification by appearance) |
- |
500 |
|
- |
| Cl-5.2, Table- 1 (i)(Blister) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (ii)(Checks) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (iii)(Discolouration) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (iv)(Dote) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (v)(Insect hole) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (vi)(Joints) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (vii)(Knots (dead)) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (viii)(Pin knots (dead)) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (ix)(Pin knots (live)) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (x)(Knots (tight)) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (xi)(Patches) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (xii)(Splits) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (xiii)(Swirl) |
- |
250 |
|
- |
| Cl-7.2.1(Thickness of veneers) |
- |
500 |
|
- |
| Cl-7.2.3(Grain Direction) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 35 |
IS 13801 (2013) |
Chequered Cement Concrete Tiles - |
- |
7000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| (Cl 7, 8 &9)(Length, Breadth, Thickness, Difference in length of side between the longest side and shorterst side in the sample shall not exceed 1 mm, Half tiles, Difference in Thickness between the thickest and thinnest tile in the sample shall not exceed 10 percent of minimum thickness, Depth of chequred groove, Thickness of wearing layer.) |
- |
500 |
|
- |
| Cl 12.1(Concavity & Convexity ) |
- |
500 |
|
- |
| Cl 12.2(Longest gap between the arms of the square and the edge of the title shall not exceed 2 percent of the length.) |
- |
500 |
|
- |
| Cl 12.3(Shall not exceed 1 percent of the length of the edge.) |
- |
500 |
|
- |
| Cl 12.4(Water absorption) |
- |
1000 |
|
- |
| Cl 12.5(Wet transverse strength) |
- |
2000 |
|
- |
| Cl 12.6(Resistance to wear) |
- |
2500 |
|
- |
|
14 Jun, 2027 |
- - |
| 36 |
IS 1079 (2017) |
Hot rolled carbon steel sheet, plate and strip - Specification (Seventh Revision) |
All Grade |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 13(Length, Width & Thickness) |
- |
1000 |
|
- |
| 8, Table 5 & 6(Tensile Strength) |
- |
1000 |
|
- |
| 8, Table 5 & 6(Yield Strength) |
- |
1000 |
|
- |
| 8, Table 5 & 6(Elongation) |
- |
1000 |
|
- |
| 9(Bend test) |
- |
1000 |
|
- |
| Clause 10(Cuppping Test) |
- |
2000 |
|
- |
| Cl 12(Workmanship) |
- |
1000 |
|
- |
| 6.1(Carbon %) |
- |
500 |
|
- |
| 6.1(Sulphur %) |
- |
500 |
|
- |
| 6.1(Phosphorus %) |
- |
500 |
|
- |
| 6.1(Manganese %) |
- |
500 |
|
- |
| 6.1(Silicon %) |
- |
500 |
|
- |
| 6.1(V) |
- |
500 |
|
- |
| 6.1( Ti) |
- |
500 |
|
- |
| 6.1( Nb) |
- |
500 |
|
- |
| 6.1( Nitrogen%) |
- |
500 |
|
- |
| 6.1( Aluminium %) |
- |
500 |
|
- |
| 6.1( Copper %) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 37 |
IS 1856 (2005) |
Steel wire ropes for haulage purposes - Specification (Third Revision) |
All Grade as per Specification |
8500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4- Tables 1 to 4(Diameter) |
- |
1000 |
|
- |
| 5- Tables 1 to 4(Breakiing Force of Rope with Steel Core) |
- |
3000 |
|
- |
| 6.3(Lay) |
- |
1000 |
|
- |
| 6.4- Tables 1 to 4(Mass of Rope with Steel core) |
- |
1500 |
|
- |
| 7(Uniformity of Znic coating - IS 1835 & IS 2366) |
- |
1000 |
|
- |
| 7(Mass of Znic Coating - IS 1835 & IS 6745) |
- |
2000 |
|
- |
| 5- Tables 1 to 4(Breakiing Force of Rope with Fiber Core) |
- |
3000 |
|
- |
| 6.4- Tables 1 to 4(Mass of Rope with Fiber core) |
- |
1500 |
|
- |
|
14 Jun, 2027 |
- - |
| 38 |
IS 10702 (1992) |
Rubber hawal chappal - Specification (Second Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.4(Stud bolt) |
- |
1000 |
|
- |
| 5.4(Stud diameter) |
- |
1000 |
|
- |
| 5.4(Hardness (Shore A)) |
- |
1000 |
|
- |
| 5.4(Hardness (shore A)- after ageing) |
- |
1000 |
|
- |
| 5.4(Tear strength ) |
- |
1000 |
|
- |
| 5.4(Breaking strength ) |
- |
1000 |
|
- |
| 5.4(Elongation at break ) |
- |
1000 |
|
- |
| 5.4(Tensile Strength ) |
- |
1000 |
|
- |
| 5.4(Relative density ) |
- |
1000 |
|
- |
| 5.4(Shrinkage test (at 100 C temp)) |
- |
1000 |
|
- |
| 5.4(Shrinkage test (at room temp)) |
- |
1000 |
|
- |
| 5.4(Split tear strength ) |
- |
1000 |
|
- |
| 5.4(Compression set) |
- |
1000 |
|
- |
| 5.4(Hardness (Shore A)) |
- |
1000 |
|
- |
| 5.4(Relative density) |
- |
1000 |
|
- |
| 5.3(Thickness ) |
- |
1000 |
|
- |
| 5.1(Shape & Design) |
- |
1000 |
|
- |
|
14 Jun, 2027 |
- - |
| 39 |
IS 1029 (1970) |
Specification for hot-rolled steel strip (Baling) (First Revision) |
All Grades |
8000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.2(Width) |
- |
500 |
|
- |
| 8.2(Thickness) |
- |
500 |
|
- |
| 5.2(Tensile Strength, Mpa) |
- |
1000 |
|
- |
| 5.2(Tensile Test-1608:Part 1) |
- |
1000 |
|
Yield Strength / 0.2 % Proof Stress |
| 5.2(Elongation, %) |
- |
1000 |
|
- |
| 5.3(Bend Test-1599) |
- |
1000 |
|
- |
| Cl.4(Sulphur -IS 228 or method specified in relevant ISO standard) |
- |
500 |
|
- |
| Cl.4(Phosphorus -IS 228 or method specified in relevant ISO standard) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 40 |
IS 1489 (Part 1) (2015) |
Portland pozzolana cement - Specification: Part 1 fly Ash Based |
PPC (Fly Ash Based) |
11000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 -Table 2- i(Fineness 4031 Part 2) |
- |
1000 |
|
- |
| 7 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
500 |
|
- |
| 7 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
1000 |
|
- |
| 7 -Table 2- ii- a(Expansion after aeration - 4031 Part 3) |
- |
0 |
|
- |
| 7 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
250 |
|
- |
| 7 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
250 |
|
- |
| 7 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 7 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 7 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 7 -Table 2- vi(Drying Shrinkage- IS 4031 Part 10) |
- |
1000 |
|
- |
| 7 -Table 2- v(Transverse Strength - IS 4031 Part 8 (Optional)) |
- |
2000 |
|
- |
| 6 - Table - 1 vi( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 v(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 iv(Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 ii(Magnesia - Cl 7.2 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 i(Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
1000 |
|
- |
|
14 Jun, 2027 |
- - |
| 41 |
IS 455 (2015) |
Portland slag cement - Specification |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 Table 1 i(Fineness
IS 4031(Part 2)) |
- |
1000 |
|
- |
| Cl. 7 Table-2(Cl. 7 Table-2 ii a (Soundness , Le Chatelier Expansion )) |
- |
500 |
|
- |
| 7 Table 1 ii b(Soundness, Autoclave expansion
IS 4031(Part 3) ) |
- |
1000 |
|
- |
| 7 Table 1 iii a(Setting Time ( by Vicat Apparatus ),Initial
IS 4031(Part 5)) |
- |
250 |
|
- |
| 7 Table 1 iii b(Setting Time ( by Vicat Apparatus ), Final
IS 4031(Part 5)) |
- |
250 |
|
- |
| 7 Table 1 iv a(Compretsive Strenqth .72 ± 1 hr
IS 4031(Part 6)) |
- |
1000 |
|
- |
| 7 Table 1 iv b(Compretsive Strenqth 168 ± 2 hr
IS 4031(Part 6)) |
- |
1000 |
|
- |
| Cl. 7 Table-2(Cl. 7 Table-2 ii b (Expansion after aeration )) |
- |
0 |
|
- |
| 7 Table 1 iv c(Compretsive Strenqth 672 ± 4 hr
IS 4031(Part 6)) |
- |
1000 |
|
- |
| 7 Table 1 v(Transverse strength (optional)
IS 4031(Part 8) ) |
- |
2000 |
|
- |
| 6 - Table - 1 vii( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 vi(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 v(Loss on ignition - Cl 6.2 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 iv(Sulphide sulphur (S) - Cl 6.12 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 6.11 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 ii(Magnesia - Cl 6.8 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 i(Insoluble residue - Cl 6.9 of IS 4032:1985) |
- |
1000 |
|
- |
|
14 Jun, 2027 |
- - |
| 42 |
IS 269 (2015) |
Ordinary portland cement - Specification (Sixth Revision) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 Table-3 i.(Fineness) |
- |
1000 |
|
- |
| 7 Table-3 ii a(Expansion by Le Chatelier) |
- |
500 |
|
- |
| 7 Table-3 ii b(Expansion by Autoclave) |
- |
1000 |
|
- |
| 7 Table-3 ii b(Expansion after aeration) |
- |
0 |
|
- |
| 7 Table-3 iii a(Setting Time Initial) |
- |
250 |
|
- |
| 7 Table-3 iii b(Setting Time Final) |
- |
250 |
|
- |
| 7 Table-3 iv a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 7 Table-3 iv b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 7 Table-3 iv c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 6.1 Table-2 viii(Alkali content) |
- |
500 |
|
- |
| 6.1 Table-2 vii(Chloride content) |
- |
500 |
|
- |
| 6.1 Table-2 vi(Loss on ignition) |
- |
500 |
|
- |
| 6.1 Table-2 v(Total Sulphur Content calculated as Sulphuric Anhydride) |
- |
500 |
|
- |
| 6.1 Table-2 iv(Magnesia) |
- |
500 |
|
- |
| 6.1 Table-2 iii.(Insoluble residue) |
- |
500 |
|
- |
| 6.1 Table-2 ii.(Ratio of percentage of alumina to that of iron oxide) |
- |
500 |
|
- |
| 6.1 Table-2 i.(Ratio of percentage of lime to percentage of silica, alumina and iron oxide) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 43 |
IS 15477 (2019) |
Adhesives for use with ceramic tiles and mosaics |
Type-1, 2, 3, 4, 5 |
23000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Classification) |
- |
1000 |
|
- |
| 5.1(Tensile Adhesion Strength ) |
- |
2500 |
|
Tensile Adhesion Strength- Dry Condition |
| 5.1(Tensile Adhesion Strength) |
- |
2500 |
|
Tensile Adhesion Strength- Wet Condition |
| 5.2(Shear Adhesion Strength ) |
- |
3000 |
|
Shear Adhesion Strength- Dry Condition |
| 5.2(Shear Adhesion Strength) |
- |
3000 |
|
Shear Adhesion Strength- Wet Condition |
| 5.2(Shear Adhesion Strength) |
- |
3000 |
|
Shear Adhesion Strength- Heat Ageing Condition |
| 5.3(OpenTime) |
- |
1000 |
|
Open time |
| 5.4(Adjustment Time) |
- |
1000 |
|
Adjustment Time |
| 5.5(Slip (Required for Vertical Application Only)) |
- |
3000 |
|
Slip |
| 5.6(Deformability (Required for VerticalApplication Only)) |
- |
3000 |
|
Deformability |
|
14 Jun, 2027 |
- - |
| 44 |
IS 14543 (2024) |
Packaged Drinking Water Other than Packaged Natural Mineral Water Specification Third Revision |
- |
21000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.3, Table-1 (i)(Colour, true colour units, Max) |
- |
150 |
|
- |
| Cl-5.3, Table-1 (ii)(Odour) |
- |
100 |
|
- |
| Cl-5.3, Table-1 (iii)(Taste) |
- |
100 |
|
- |
| Cl-5.3, Table-1 (iv)(Turbidity, nephelometric turbidity unit (NTU), Max) |
- |
150 |
|
- |
| Cl-5.3, Table-1 (v)(Total dissolved solids, mg/l, Max) |
- |
150 |
|
- |
| Cl-5.3, Table-1 (vi)(pH) |
- |
150 |
|
- |
| Cl-5.3, Table-2 (i)(Barium (as Ba)) |
- |
275 |
|
- |
| Cl-5.3, Table-2 (ii)(Copper (as Cu)) |
- |
275 |
|
- |
| Cl-5.3, Table-2 (iii)(Iron (as Fe)) |
- |
275 |
|
- |
| Cl-5.3, Table-2 (iv)(Manganese (as Mn)) |
- |
275 |
|
- |
| Cl-5.3, Table-2 (v)(Nitrate (as NO3 )) |
- |
300 |
|
- |
| Cl-5.3, Table-2 (vi)(Nitrite (as NO2 )) |
- |
300 |
|
- |
| Cl-5.3, Table-2 (vii)(Fluoride (as F)) |
- |
300 |
|
- |
| Cl-5.3, Table-2 (viii)(Zinc (as Zn)) |
- |
275 |
|
- |
| Cl-5.3, Table-2 (ix)(Silver (as Ag)) |
- |
275 |
|
- |
| Cl-5.3, Table-2 (x)(Aluminium (as A1)) |
- |
275 |
|
- |
| Cl-5.3, Table-2 (xi)(Chloride (as Cl)) |
- |
150 |
|
- |
| Cl-5.3, Table-2 (xii)(Selenium (as Se)) |
- |
275 |
|
- |
| Cl-5.3, Table-2 (xiii)(Sulphate (as SO4 )) |
- |
275 |
|
- |
| Cl-5.3, Table-2 (xiv)(Alkalinity (as HCO3 )) |
- |
150 |
|
- |
| Cl-5.3, Table-2 (xv)(Calcium (as Ca)) |
- |
150 |
|
- |
| Cl-5.3, Table-2 (xvi)(Magnesium (as Mg)) |
- |
150 |
|
- |
| Cl-5.3, Table-2 (xvii)(Sodium (as Na)) |
- |
275 |
|
- |
| Cl-5.3, Table-2 (xviii)(Residual free chlorine) |
- |
300 |
|
- |
| Cl-5.3, Table-2 (xix)(Phenolic compounds (as C6H5OH)) |
- |
300 |
|
- |
| Cl-5.3, Table-2 (xx)(Mineral oil) |
- |
300 |
|
- |
| Cl-5.3, Table-2 (xxi)(Anionic surface active agents) |
- |
300 |
|
- |
| Cl-5.3, Table-2 (xxii)(Sulphide) |
- |
300 |
|
- |
| Cl-5.3, Table-2 (xxiii)(Antimony (as Sb)) |
- |
275 |
|
- |
| Cl-5.3, Table-2 (xxiv)(Borates (as B)) |
- |
275 |
|
- |
| Cl-5.3, Table-2 (xxv)(Bromates (as BrO3 )) |
- |
500 |
|
- |
| Cl-5.3, Table-3 (i)(Mercury (as Hg)) |
- |
300 |
|
- |
| Cl-5.3, Table-3 (ii)(Cadmium (as Cd)) |
- |
300 |
|
- |
| Cl-5.3, Table-3 (iii)(Arsenic (as As)) |
- |
300 |
|
- |
| Cl-5.3, Table-3 (iv)(Cyanide (as CN)) |
- |
500 |
|
- |
| Cl-5.3, Table-3 (v)(Lead (as Pb)) |
- |
300 |
|
- |
| Cl-5.3, Table-3 (vi)(Chromium (as Cr)) |
- |
300 |
|
- |
| Cl-5.3, Table-3 (vii)(Nickel (as Ni)) |
- |
300 |
|
- |
| Cl-5.3, Table-3 (viii)(Polychlorinated biphenyl (PCB)) |
- |
500 |
|
- |
| Cl-5.3, Table-3 (ix)(Polynuclear aromatic hydrocarbons) |
- |
500 |
|
- |
| 5.4/Annex D/i(P,P-DDT) |
- |
150 |
|
- |
| 5.4/Annex D/ii(Lindane) |
- |
150 |
|
- |
| 5.4/Annex D/iv(b-Endosulfan) |
- |
150 |
|
- |
| 5.4/Annex D/xvi(Dieldrin) |
- |
150 |
|
- |
| 5.4/Annex D/xvi(Aldrin) |
- |
150 |
|
- |
| 5.4/Annex D/i(O,P-DDT) |
- |
150 |
|
- |
| 5.4/Annex D/iv(a-Endosulfan) |
- |
150 |
|
- |
| 5.4/Annex D/iii(d-HCH) |
- |
150 |
|
- |
| 5.4/Annex D/i(O,P-DDD) |
- |
150 |
|
- |
| 5.4/Annex D/i(P,P-DDE) |
- |
150 |
|
- |
| 5.4/Annex D/i(O,P-DDE) |
- |
150 |
|
- |
| 5.4/Annex D/iii(a-HCH) |
- |
150 |
|
- |
| 5.4/Annex D/iii(β- HCH) |
- |
150 |
|
- |
| 5.4/Annex D/iv(Endosulfan sulfate) |
- |
150 |
|
- |
| 5.4/Annex D/i(P,P-DDD) |
- |
150 |
|
- |
| 5.4/Annex D/xii(Alachlor) |
- |
150 |
|
- |
| 5.4/Annex D/vii(Chlorpyrifos) |
- |
150 |
|
- |
| 5.4/Annex D/x(Butachlor) |
- |
150 |
|
- |
| 5.4/Annex D/vi(Ethion) |
- |
150 |
|
- |
| 5.4/Annex D/xiv(Methyl parathion) |
- |
150 |
|
- |
| 5.4/Annex D/xv(Malathion) |
- |
150 |
|
- |
| 5.4/Annex D/viii(Phorate) |
- |
150 |
|
- |
| 5.4/Annex D/v(Monochrotophos) |
- |
150 |
|
- |
| 5.4/Annex D/xiii(Atrazine) |
- |
150 |
|
- |
| 5.4/Annex D/viii(Phorate sulphoxide) |
- |
150 |
|
- |
| 5.4/Annex D/viii(Phorate sulfone) |
- |
150 |
|
- |
| 5.4/Annex D/xxvii(Methyl paraoxon) |
- |
150 |
|
- |
| 5.4/Annex D/xxviii(Malaoxon) |
- |
150 |
|
- |
| 5.4/Annex D/xi(Isoproturon) |
- |
150 |
|
- |
| 5.4/Annex D/ix(2,4 –D) |
- |
150 |
|
- |
| Cl-5.2.1(Escherichia coli or thermotolerant bacteria) |
- |
400 |
|
- |
| Cl-5.2.2(Coliform) |
- |
400 |
|
- |
| Cl-5.2.3(Staphylococcus aureus) |
- |
400 |
|
- |
| Cl-5.2.4(Sulphite Reducing Anaerobes) |
- |
400 |
|
- |
| Cl-5.2.5(Pseudomonas Aeruginosa) |
- |
400 |
|
- |
| 5.2.6(Aerobic Microbial Count @ 20 to 22 deg C) |
- |
0 |
|
- |
| Cl-5.2.7(Yeast and mould) |
- |
400 |
|
- |
| Cl-5.2.8(Salmonella) |
- |
400 |
|
- |
| Cl-5.2.9(Vibrio cholera) |
- |
400 |
|
- |
| Cl-5.4 (i)(Pesticide residues considered individually) |
- |
250 |
|
- |
| Cl-5.4 (ii)(Total pesticide residue) |
- |
250 |
|
- |
| 5.3(Appearance) |
- |
100 |
|
- |
| Cl-5.2.3(Faecal streptococci) |
- |
400 |
|
- |
| Cl-5.2.8(shigella) |
- |
400 |
|
- |
| Cl-5.2.9(V.parahaemolyticus) |
- |
400 |
|
- |
| Cl-5.1(General Requirements) |
- |
200 |
|
- |
| Cl-5.2.6(Aerobic Microbial Count @ 37 deg C) |
- |
400 |
|
- |
|
14 Jun, 2027 |
- - |
| 45 |
IS 3319 (1995) |
Blades, surgical, detachable (Bard Parker Type) and handles - Specification (Fourth Revision) |
- |
14900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5,5.1 & 5.2; Table 1(Shape and dimensions) |
- |
1000 |
|
- |
| 6,6.1(Workmanship and Finish) |
- |
1000 |
|
- |
| 6,6.2(Workmanship and Finish) |
- |
0 |
|
- |
| 6,6.3(Workmanship and Finish) |
- |
0 |
|
- |
| 6,6.4(Workmanship and Finish) |
- |
0 |
|
- |
| 7.1(Hardness test) |
- |
2000 |
|
- |
| 9.1( Visual Examination) |
- |
1000 |
|
- |
| 9.2( Performance Test) |
- |
2000 |
|
- |
| 10.1.1( Marking on Blade) |
- |
100 |
|
- |
| 10.1.2(Packages of Non-sterile Blades) |
- |
100 |
|
- |
| 10.1.3,10.1.3.1(Packages of sterile Blades,Unit containers for sterile Blades) |
- |
100 |
|
- |
| 10.1.3,10.1.3.2(Packages of sterile Blades , Outer containers for sterile blade) |
- |
0 |
|
- |
| 10.2( Handles) |
- |
0 |
|
- |
| 10.2.2( Packages of Handles) |
- |
100 |
|
- |
| 11,11.1,11.1.1( Packages of Non-sterile Blades ; Unit container) |
- |
0 |
|
- |
| 11,11.1,11.1.2( Packages of Non-sterile Blades ; Outer container) |
- |
0 |
|
- |
| 11.2,11.2.1(Packages of Sterile Blades) |
- |
0 |
|
- |
| 11.2,11.2.2( Packages of Sterile Blades ; Unit container) |
- |
0 |
|
- |
| 11.2,11.2.3( Packages of sterile Blades ; Outer container) |
- |
0 |
|
- |
| 11.4(Packaging of Handles) |
- |
0 |
|
- |
| Clause -4, 4.1(TITANIUM) |
- |
500 |
|
- |
| Clause -4, 4.1(VANADIUM) |
- |
500 |
|
- |
| Clause -4, 4.1(Molybdenum) |
- |
500 |
|
- |
| Clause -4, 4.1(Chromium) |
- |
500 |
|
- |
| Clause -4, 4.1(Nickel) |
- |
500 |
|
- |
| Clause -4, 4.1( ALUMINIUM) |
- |
500 |
|
- |
| Clause -4, 4.1(SILICON) |
- |
500 |
|
- |
| Clause -4, 4.1(MANGANESE) |
- |
500 |
|
- |
| Clause -4, 4.1(PHOSPHURS) |
- |
500 |
|
- |
| Clause -4, 4.1(SULPHUR) |
- |
500 |
|
- |
| Clause -4, 4.1( CARBON) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 46 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
1200 |
|
- |
| 6(Interchangeability) |
- |
1200 |
|
- |
| 7(Protection against accidental contact with live parts) |
- |
1200 |
|
- |
| 8(Insulation Resistance and Electric Strength) |
- |
5000 |
|
- |
| 9(MECHANICAL STRENGTH) |
- |
1200 |
|
- |
| 10(cap temperature) |
- |
2000 |
|
- |
| 11(Resistance to Heat) |
- |
2000 |
|
- |
| 12(Resistance to Flame and Ignition) |
- |
5000 |
|
- |
| 13(Fault conditions) |
- |
2000 |
|
- |
| 14(Creepage distance and clearances) |
- |
1200 |
|
- |
| 4(General requirement and General test requirements) |
- |
0 |
|
- |
| 8(Strength after humidity treatment) |
- |
5000 |
|
- |
| 5(Marking) |
- |
1200 |
|
- |
| 6(Interchangeability) |
- |
1200 |
|
- |
| 7(Protection against accidental contact with live parts) |
- |
1200 |
|
- |
| 9(Mechanical strength) |
- |
1200 |
|
- |
| 10(Cap temperature rise) |
- |
2000 |
|
- |
| 11(Resistance to heat) |
- |
2000 |
|
- |
| 12(Resistance to flame and ignition) |
- |
5000 |
|
- |
| 13(Fault conditions) |
- |
2000 |
|
- |
| 14(Creepage distances and clearances) |
- |
1200 |
|
- |
| 15(Selection of lamps for tests (Sampling)) |
- |
0 |
|
- |
| 16(Condition of compliance) |
- |
0 |
|
- |
| 17(Tests) |
- |
0 |
|
- |
| Annex A(Ovreview of systems composed of LED modules and control gear) |
- |
0 |
|
- |
| Annex B(Lamps with operating position limitations) |
- |
0 |
|
- |
| 4(GENERAL REQUIREMENT AND GENERAL TEST REQUIREMENTS) |
- |
0 |
|
- |
|
14 Jun, 2027 |
- - |
| 47 |
IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
| 6.0(Marking) |
- |
1200 |
|
- |
| 7.0(Construction) |
- |
1200 |
|
- |
| 8.0(Creepage Distance and Clearances) |
- |
1200 |
|
- |
| 9.0(Provision for earthing) |
- |
1200 |
|
- |
| 10.0(Terminals) |
- |
1200 |
|
- |
| 11.0(External & Internal Wiring) |
- |
1200 |
|
- |
| 12.0(Protection against electric shock) |
- |
1200 |
|
- |
| 13.0(Endurance Tests and Thermal Tests) |
- |
5500 |
|
- |
| 14.0(Resistance to Dust & Moisture) |
- |
12000 |
|
- |
| 15.0(Insulation Resistance and Electric Strength) |
- |
5000 |
|
- |
| 16.0(Resistance to Heat , fire and tracking) |
- |
12000 |
|
- |
| 17.0(Photometric Test) |
- |
10000 |
|
- |
| (Cl.4.24) (Annex-P)(UV Radiations for metal halide lamps) |
- |
0 |
|
- |
| 4.26.2(Short Circuit Protection) |
- |
0 |
|
- |
|
14 Jun, 2027 |
- - |
| 48 |
IS 16103 : Part 1 (2012) |
Led modules for general lighting: Part 1 safety requirements |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
500 |
|
NA |
| 8(Terminals) |
- |
500 |
|
NA |
| 9(PROVISION FOR EARTHING) |
- |
1000 |
|
NA |
| 10(Protection against accidental contact with live parts) |
- |
500 |
|
NA |
| 11(Mositure Resistance and Insulation) |
- |
3500 |
|
NA |
| 12(Electric Strength) |
- |
1500 |
|
NA |
| 13(Fault conditions) |
- |
1500 |
|
NA |
| 15(Construction) |
- |
500 |
|
NA |
| 16(Creepage distance and clearances) |
- |
500 |
|
NA |
| 17(Screws, current carrying parts and connections) |
- |
1000 |
|
NA |
| 18(Resistance to heat, fire and tracking) |
- |
12000 |
|
NA |
| 19(Resistance to corrosion) |
- |
2000 |
|
NA |
|
14 Jun, 2027 |
- - |
| 49 |
IS 16103 : Part 2 (2012) |
Led modules for general lighting: Part 2 performance requirements |
- |
60000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Dimensions) |
- |
500 |
|
NA |
| 7(Module Power) |
- |
2000 |
|
NA |
| 8(Light Output) |
- |
5000 |
|
NA |
| 9(Chromaticity
Coordinates,
Correlated colour
temperature and
colour rendering) |
- |
5000 |
|
NA |
| 10(LED Module Life) |
- |
45000 |
|
NA |
| 12(Information for
Luminaire design) |
- |
500 |
|
NA |
|
14 Jun, 2027 |
- - |
| 50 |
IS 16104 (2012) |
D.C. or A.C. supplied electronic control gear for led modules - Performance requirements |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Classification) |
- |
500 |
|
NA |
| 6(Marking) |
- |
500 |
|
NA |
| 7.2(Output voltage and
Current) |
- |
1000 |
|
NA |
| 7.3(Capacitive Load
Requirement) |
- |
500 |
|
NA |
| 7.4(Voltage surge during
switching and operation) |
- |
1500 |
|
NA |
| 8(Total Circuit
Power) |
- |
2000 |
|
NA |
| 9(Circuit Power
Factor) |
- |
1000 |
|
NA |
| 10(Supply Current) |
- |
1000 |
|
NA |
| 12(Operational test
for abnormal conditions) |
- |
2000 |
|
NA |
| 13(Endurance) |
- |
20000 |
|
NA |
|
14 Jun, 2027 |
- - |
| 51 |
IS 10322 : Part 5 : Sec 4 (1987) |
Specification for luminaires: Part 5 particular requirements: Sec 4 portable general purpose luminaires |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
500 |
|
Individual test charge 1200/- per sample for this tests. |
| 6(Construction) |
- |
1000 |
|
Individual test charge 1200/- per sample for this tests. |
| 7(Creepage Distance
And Clearances) |
- |
1000 |
|
Individual test charge 1200/- per sample for this tests. |
| 8(Provision for
Earthing) |
- |
1000 |
|
Individual test charge 1200/- per sample for this tests. |
| 9(Terminals) |
- |
1000 |
|
Individual test charge 1200/- per sample for this tests. |
| 10(External &
Internal Wiring) |
- |
500 |
|
Individual test charge 1200/- per sample for this tests. |
| 11(Protection Against
Electric Shock ) |
- |
1000 |
|
Individual test charge 1200/- per sample for this tests. |
| 13.3(Mechanical
Strength Test ) |
- |
1000 |
|
Individual test charge 1200/- per sample for this tests. |
| 13.4(Endurance Test
and Thermal test) |
- |
5000 |
|
Individual test charge 5500/- per sample for this tests. |
| 13.5(Resistance To
Dust & Moisture) |
- |
7500 |
|
Individual test charge 12000/- per sample for this tests. |
| 13.6(Insulation Resistance
and Electric Strength) |
- |
3000 |
|
Individual test charge 5000/- per sample for this tests. |
| 13.7(Resistance to Heat,
Fire & Tracking) |
- |
7500 |
|
Individual test charge 12000/- per sample for this tests. |
| 13.8(Photometric Test) |
- |
10000 |
|
NA |
|
14 Jun, 2027 |
- - |
| 52 |
IS 10322 : Part 5 : Sec 7 (2017) |
Luminaires: Part 5 particular requirements: Sec 7 lighting chains (First Revision) |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 20.4(General Test Requireements) |
- |
500 |
|
Individual test charge 1200/- per sample for this tests. |
| 20.5(Classification of Luminaires') |
- |
500 |
|
Individual test charge 1200/- per sample for this tests. |
| 20.6(Marking) |
- |
500 |
|
Individual test charge 1200/- per sample for this tests. |
| 20.7(Construction) |
- |
1000 |
|
Individual test charge 1200/- per sample for this tests. |
| 20.8(Creepage Distance and Clearances) |
- |
1000 |
|
Individual test charge 1200/- per sample for this tests. |
| 20.9(Provision for earthing) |
- |
1000 |
|
Individual test charge 1200/- per sample for this tests. |
| 20.10(Terminals) |
- |
1000 |
|
Individual test charge 1200/- per sample for this tests. |
| 20.11(External & Internal Wiring) |
- |
500 |
|
Individual test charge 1200/- per sample for this tests. |
| 20.12(Protection against electric shock) |
- |
1000 |
|
Individual test charge 1200/- per sample for this tests. |
| 20.13(Endurance Tests and Thermal Tests) |
- |
5000 |
|
Individual test charge 5500/- per sample for this tests. |
| 20.14(Resistance to Dust & Moisture) |
- |
7500 |
|
Individual test charge 12000/- per sample for this tests. |
| 20.15(Insulation Resistance and Electric Strength) |
- |
3000 |
|
Individual test charge 5000/- per sample for this tests. |
| 20.16(Resistance to Heat , fire and tracking) |
- |
7500 |
|
Individual test charge 12000/- per sample for this tests. |
|
14 Jun, 2027 |
- - |
| 53 |
IS 10322 : PART 5 : SEC 3 (2012) |
Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
| 6.0(Marking) |
- |
1200 |
|
- |
| 7.0(Construction) |
- |
1200 |
|
- |
| 8.0(Creepage Distance and Clearances) |
- |
1200 |
|
- |
| 9.0(Provision for earthing) |
- |
1200 |
|
- |
| 10.0(Terminals) |
- |
1200 |
|
- |
| 11.0(External & Internal Wiring) |
- |
1200 |
|
- |
| 12.0(Protection against electric shock) |
- |
1200 |
|
- |
| 13.0(Endurance Tests and Thermal Tests) |
- |
5500 |
|
- |
| 14.0(Resistance to Dust & Moisture) |
- |
12000 |
|
- |
| 15.0(Insulation Resistance and Electric Strength) |
- |
5000 |
|
- |
| 16.0(Resistance to Heat , fire and tracking) |
- |
12000 |
|
- |
| 17.0(Photometric Test) |
- |
10000 |
|
- |
|
14 Jun, 2027 |
- - |
| 54 |
IS 10322 : Part 5 : Sec 5 (2013) |
Luminaires: Part 5 particular requirements: Sec 5 floodlights (First Revision) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
| 6.0(Marking) |
- |
1200 |
|
- |
| 7.0(Construction) |
- |
1200 |
|
- |
| 8.0(Creepage Distance and Clearances) |
- |
1200 |
|
- |
| 9.0(Provision for earthing) |
- |
1200 |
|
- |
| 10.0(Terminals) |
- |
1200 |
|
- |
| 11.0(External & Internal Wiring) |
- |
1200 |
|
- |
| 12.0(Protection against electric shock) |
- |
1200 |
|
- |
| 13.0(Endurance Tests and Thermal Tests) |
- |
5500 |
|
- |
| 14.0(Resistance to Dust & Moisture) |
- |
12000 |
|
- |
| 15.0(Insulation Resistance and Electric Strength) |
- |
5000 |
|
- |
| 16.0(Resistance to Heat , fire and tracking) |
- |
12000 |
|
- |
| 17.0(Photometric Test) |
- |
10000 |
|
- |
|
14 Jun, 2027 |
- - |
| 55 |
IS 10322 : Part 5 : Sec 6 (2013) |
Luminaires: Part 5 particular requirements: Sec 6 handlamps |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.2(Packing -Each Package shall bear the following Particulars) |
- |
0 |
|
- |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
| 6.0(Marking) |
- |
1200 |
|
- |
| 7.0(Construction) |
- |
1200 |
|
- |
| 8.0(Creepage Distance and Clearances) |
- |
1200 |
|
- |
| 9.0(Provision for earthing) |
- |
1200 |
|
- |
| 10.0(Terminals) |
- |
1200 |
|
- |
| 11.0(External & Internal Wiring) |
- |
1200 |
|
- |
| 12.0(Protection against electric shock) |
- |
1200 |
|
- |
| 13.0(Endurance Tests and Thermal Tests) |
- |
5500 |
|
- |
| 14.0(Resistance to Dust & Moisture) |
- |
12000 |
|
- |
| 15.0(Insulation Resistance and Electric Strength) |
- |
5000 |
|
- |
| 16.0(Resistance to Heat , fire and tracking) |
- |
12000 |
|
- |
|
14 Jun, 2027 |
- - |
| 56 |
IS 3975 (1999) |
Low carbon galvanized steel wires, formed wires and tapes for armouring of cables - Specification (Third Revision) |
- |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Dimensions) |
- |
1000 |
|
- |
| 8.1(Mechanical Properties (as per table 5 of IS 1608)) |
- |
3000 |
|
- |
| 8.2(Mechanical Properties (as per IS 1717)) |
- |
1000 |
|
- |
| 8.3(Mechanical Properties (as per IS 1755)) |
- |
1000 |
|
- |
| 9.1(Galvanizing Requirements ) |
- |
2000 |
|
- |
| 9.2(Galvanizing Requirements ) |
- |
1000 |
|
- |
| 9.3(Galvanizing Requirements ) |
- |
1000 |
|
- |
| 11(Freedom from defects) |
- |
1000 |
|
- |
| 6.2(Sulphur %) |
- |
500 |
|
- |
| 6.2(Phosphorus %) |
- |
500 |
|
- |
| 8.4(Mechanical Properties (as per IS 10810(Part- 42))) |
- |
3000 |
|
- |
|
14 Jun, 2027 |
- - |
| 57 |
IS 10702 (2023) |
Hawai Chappal-Specification |
- |
31000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Material) |
- |
2000 |
|
- |
| 4.2(Length) |
- |
500 |
|
- |
| 4.3(Thickness) |
- |
500 |
|
- |
| 4.4 , Table No. 1 , i)(Density) |
- |
1000 |
|
- |
| 4.4 , Table No. 1 , iii)(3Split tear strength) |
- |
2000 |
|
- |
| 4.4 , Table No. 1 , iv)("Shrinkage at 50 ºC ± 1 ºC for 24 h for polymeric material,
Shrinkage at 100 ºC ± 1 ºC for 1 h for rubber") |
- |
1000 |
|
- |
| 4.4 , Table No. 1 , v)(5Abrasion resistance at applied force) |
- |
1000 |
|
- |
| 4.4 , Table No. 1 , vi)(Flexing resistance: Maximum cut growth at 50 000 flexes) |
- |
2000 |
|
- |
| 4.4 , Table No. 1 , vii)(7 Hydrolysis resistance, Maximum cut growth at 50 000 flexes) |
- |
2000 |
|
- |
| 4.4 , Table No . 2 , i)(Density , Solid strap, Cellular strap) |
- |
1000 |
|
- |
| 4.4 , Table No . 2 , ii)("Breaking strength , Strap to strap and
Toe portion to strap , Elongation at break") |
- |
2000 |
|
- |
| 4.4 , Table No . 2 , iii)(Minimum cross section of the stud) |
- |
500 |
|
- |
| 4.4 , Table No . 2 , iv)(Stud bolt) |
- |
500 |
|
- |
| 4.4 , Table No . 3 , iii)(Inter layer bond strength) |
- |
2000 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(x)(pH) |
- |
1000 |
|
- |
| Cl.No. 5.2(lead content) |
- |
500 |
|
- |
| Cl-4.4, Table -2 S. No-1 (iii), (Amendment No-1)(Lead content (as Pb), in ppm, Max) |
- |
500 |
|
- |
| Cl.4.4 - Table No 1 - Sl. No.-viii("Lead Content (as Pb) (applicable for PVC only)
- IS 12240 (Part 5) : 1988") |
- |
500 |
|
- |
| Clause 4.1 - 4.1.1(Bottom Material) |
- |
500 |
|
- |
| Clause 4.1 - 4.1.2(Strap Material) |
- |
2000 |
|
- |
| Clause 4.1 - 4.1.3(Material) |
- |
500 |
|
- |
| Clause 4.1 - 4.1.4(Material) |
- |
500 |
|
- |
| Clause 4.2(Material) |
- |
500 |
|
- |
| Clause 4.3 - 4.3.1(Thickness) |
- |
500 |
|
- |
| Clause 4.3 - 4.3.2(Thickness) |
- |
500 |
|
- |
| Clause 4.4 Table 1 -i)(Density, g/cm3, Min) |
- |
1000 |
|
- |
| Clause 4.4 Table 1 -iii)(Split tear strength, kg, Min) |
- |
2000 |
|
- |
| Clause 4.4 Table 1 -iv) - a("Shrinkage at 50 ºC ± 1 ºC for 24 h for polymeric material, percent,
Max") |
- |
1000 |
|
- |
| Clause 4.4 Table 1 -iv) - b(Shrinkage at 100 ºC ± 1 ºC for 1 h for rubber, percent, Max) |
- |
1000 |
|
- |
| Clause 4.4 Table 1 -v)(Abrasion resistance at applied force 5 N) |
- |
1000 |
|
- |
| Clause 4.4 Table 2 -i) - a("Density, g/cm3
Solid strap
") |
- |
1000 |
|
- |
| Clause 4.4 Table 2 -i) - b(Density, g/cm3 Cellular strap) |
- |
1000 |
|
- |
| Clause 4.4 Table 2 -ii) - a - 1("Breaking strength, kgf, Min
Strap to strap(Solid Strap)") |
- |
1000 |
|
- |
| Clause 4.4 Table 2 -ii) - a - 2("Breaking strength, kgf, Min
Strap to strap(Cellular Strap)") |
- |
1000 |
|
- |
| Clause 4.4 Table 2 -ii) - a - 3("Breaking strength, kgf, Min
Toe portion to strap(Solid Strap)") |
- |
1000 |
|
- |
| Clause 4.4 Table 2 -ii) - a - 4("Breaking strength, kgf, Min
Toe portion to strap(Cellular Strap)") |
- |
1000 |
|
- |
| Clause 4.4 Table 2 -ii) - b - 1("Elongation at break, percent
(Applicable to strap to strap
(V shape) Solid Strap") |
- |
1000 |
|
- |
| Clause 4.4 Table 2 -ii) - b - 2("Elongation at break, percent
(Applicable to strap to strap
(V shape) Cellular Strap") |
- |
1000 |
|
- |
| Clause 4.4 Table 2 -iii) - a("Minimum cross section of the
stud, mm,
Size 1 to 13 (Adult)") |
- |
500 |
|
- |
| Clause 4.4 Table 2 -iii) - b("Minimum cross section of the
stud, mm,
Size 3 to 13 (Children)") |
- |
500 |
|
- |
| Clause 4.4 Table 2 -iv) - a("Stud bolt, mm
Diameter/edge to edge length") |
- |
500 |
|
- |
| Clause 4.4 Table 2 -iv) - b("Stud bolt, mm
Thickness") |
- |
500 |
|
- |
| Clause 4.4 Table 3 -iii)("Inter layer bond strength, N/mm,
Min") |
- |
1000 |
|
- |
| Cl-4.4, Table -1 S. No-1 (ii) (Amendment No-1)(Split tear strength) |
- |
2000 |
|
- |
| Cl-4.4, Table -1 S. No-1 (iii) (a)(Amendment No-1)("Shrinkage at Shrinkage at 50 °C ± 1 °C for 2 h for polymeric material, percent, Max
") |
- |
1000 |
|
- |
| Cl-4.4, Table -1 S. No-1 (iii)(b) (Amendment No-1)(Shrinkage at 100 °C ± 1 °C for 1 h for rubber, percent, Max) |
- |
1000 |
|
- |
| Cl-4.4, Table -1 S. No-1 (iv) (Amendment No-1)(Abrasion resistance at applied force) |
- |
1000 |
|
- |
| Cl-4.4, Table -1 S. No-1 (v) (Amendment No-1)(Flexing resistance: Maximum cut growth,) |
- |
2000 |
|
- |
| Cl-4.4, Table -1 S. No-1 (vi) (Amendment No-1)(Hydrolysis resistance:Maximum cut growth) |
- |
2000 |
|
- |
| Cl-4.4, Table -1 S. No-1 (viii) (Amendment No-1)("Lead content (as Pb),
ppm, Max") |
- |
500 |
|
- |
| Cl-4.4, Table -2 S. No-1 (i), a (Amendment No-1)("Breaking strength for Strap to strap
1-Solid strap
2-Cellular strap") |
- |
500 |
|
- |
| Cl-4.4, Table -2 S. No-1 (i), b (Amendment No-1)("Breaking strength for Toe portion to strap
1-Solid strap
2-Cellular strap") |
- |
1000 |
|
- |
| Cl-4.4, Table -2 S. No-1 (i), c (Amendment No-1)("Elongation at break , percent, Min
1-Solid strap
2-Cellular strap") |
- |
1000 |
|
- |
| 6(MARKING AND PACKING) |
- |
500 |
|
- |
| Cl-4.4, Table -3 S. No-1 (iii), (Amendment No-1)(Inter layer bond strength) |
- |
2000 |
|
- |
| Cl.4.4 - Table No 1 - Sl. No.-vii(pH- IS 1390:2022) |
- |
1000 |
|
- |
|
14 Jun, 2027 |
- - |
| 58 |
IS 12894 (2002) |
Pulverized fuel ash - Lime bricks - Specification |
- |
5000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Dimensions) |
- |
500 |
|
- |
| 7.1, Table -1(Average Wet Compressive Strength) |
- |
2000 |
|
- |
| 7.4(Water Absorption) |
- |
1000 |
|
- |
| 7.3(Efflorescence Test) |
- |
1000 |
|
- |
| 3.1(General Requirements) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 59 |
IS 1237 (2012) |
Cement Concrete Flooring Tiles - Specification |
- |
7000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 7.1(Length, Breadth, Minimum thickness, Difference in length of side between the longest side and shorterst side, Half tiles, Difference in Thickness between the thickest and thinnest tile, Thickness of wearing layer) |
- |
500 |
|
- |
| Cl 12.2(Concavity & Convexity ) |
- |
500 |
|
- |
| Cl 12.3(The Maximum gap between the arms of the square and the edge of the title shall notexceed 2 percent of the length.) |
- |
500 |
|
- |
| Cl 12.4(Shall not exceed 1 percent of the length of the edge.) |
- |
500 |
|
- |
| Cl 12.5(Water absorption) |
- |
1000 |
|
- |
| Cl 12.6(Wet transverse strength ) |
- |
2000 |
|
- |
| Cl 12.7(Resistance to wear) |
- |
2500 |
|
- |
|
14 Jun, 2027 |
- - |
| 60 |
IS 15647 (2006) |
Hot rolled steel narrow width strip for welded tubes and pipes |
- |
9165 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8(Tensile Strength-IS:1608(P1)) |
- |
2000 |
|
- |
| 8(Yield Strength-IS:1608(P1)) |
- |
500 |
|
- |
| Cl. 8.2 Table 3(Elongation) |
- |
500 |
|
- |
| Cl 9(Press) |
- |
1000 |
|
- |
| Cl 11(Workmanship) |
- |
1000 |
|
- |
| Cl 12(Length, Width & Thickness) |
- |
1000 |
|
- |
| 7(Carbon as C - IS:228) |
- |
500 |
|
- |
| 7(Sulphur as S- IS:228) |
- |
500 |
|
- |
| 7(Phosphorus as P-IS:228) |
- |
500 |
|
- |
| 7(Manganese as Mn-IS:228) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |