BLUESKY LAB LLP

Plot no. 62, 63, 1st 2nd 3rd Floor, Ganga Enclave, Behta Hajipur, Main Delhi Saharanpur Road, Near Johri Enclave Metro Station, Ghaziabad, Uttar Pradesh, 201102, Ghaziabad, Ghaziabad, Uttar Pradesh, 201102
9953745002 info@blueskylab.in
Scope List
Reset
35 Results
S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Exclusion Testing Charges (Excl. Of Taxes) Facility Type Effective Date Validity Date Remark
1 IS 302 : Part 2 : SEC 31 (2009) Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 31 range hoods - - 25000 View breakup
-
Complete 22 May, 2028 -
Included w.e.f.025.03.2025 Exclusion Clause No -19.11.4.1 to Clause No -19.11.4.3 (EMI/EMC) Clause No -24.1.2 (safety isolating transformer) Clause No -24.1.3 (for switches) Clause No -24.1.5 (for innterconnection couplers) Clause No -24.4 (plug and socket)
2 IS 302 : Part 2 : Sec 23 (2009) Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 23 appliances for skin or hair care (First Revision) - - 25000 View breakup
-
Complete 22 May, 2028 -
Included w.e.f.27.02.2025 Exclusion Cl 19.11.4.1 Electrostatic discharge Cl 19.11.4.2 (Radiated fields) 24 (Components) Cl 19.11.4.3 (Fast transient bursts) Cl 19.11.4.4 (Surge immunity test) Cl 19.11.4.5 (Immunity to conducted discharges) Cl 19.11.4.6 (Class 3 Voltage dips and interruptions) Cl 19.11.4.7 (Harmonics)
3 IS 302 : Part 2 : Sec 9 (2009) Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 9 toasters, grills, roasters and similar appliances (First Revision) - - 25000 View breakup
-
Complete 22 May, 2028 -
Included w.e.f.27.02.2025 Exclusion CL 19.11.4.1 (Electrostatic discharges) CL 19.11.4.2 (Radiated fields) CL 19.11.4.3 (Fast transient bursts) CL 19.11.4.5 (Immunity to conducted discharges) CL 19.11.4.6 (Class 3 Voltage dips and interruptions) CL 19.11.4.7 (Harmonics) CL 32 (Radiation, toxicity and similar hazards) CL 24 (Components)
4 IS 302 : Part 1 (2024) Household and Similar Electrical Appliances — Safety Part 1 General Requirements (Seventh Revision) - - 20000 View breakup
-
Complete 22 May, 2028 -
Included.w.e.f.13.01.2025 Exclusion Cl 19.11.4.1 to 19.11.4.7 (EMI/EMC) Cl 24 (Components) Cl 32 (Radiation Toxicity and Similar Hazards)
5 IS 302 : Part 2 : Sec 21 (2024) Household and Similar Electrical Appliances�Safety Part 2 Particular Requirements Section 21 Storage Water Heaters - - 20000 View breakup
-
Complete 22 May, 2028 -
Included.w.e.f.23.12.2024 exclusion CL 19.11.4.1 (Electrostatic discharges) CL 19.11.4.2 (Radiated fields) CL 19.11.4.3 (Fast transient bursts) CL 19.11.4.5 (Immunity to conducted discharges) CL 19.11.4.6 (Class 3 Voltage dips and interruptions) CL 19.11.4.7 (Harmonics) CL 32 (Radiation, toxicity and similar hazards) CL 24 (Components)
6 IS 16333 : Part 3 (2022) Mobile phone handsets: Part 3 Indian language support for mobile phone handsets - Specific requirements(Second Revision) - - 15000 View breakup
-
Complete 22 May, 2028 -
Included we.f. 07-09-2022.
7 IS 302 : Part 2 : Sec 14 (2009) Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision) - - 14700 View breakup
-
Complete 22 May, 2028 -
EMI/EMC tests (Electrostatic discharges, radiant fields, fast transient bursts, voltage surges, injected current, voltage dip and interruption, mains signals) (Cl.19.11.4.1 to 19.11.4.7)
8 IS 302 : Part 1 (2008) Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) - - 42000 View breakup
-
Complete 22 May, 2028 view Scope file
Exclusions: EMI/EMC (ESD, Radiated fields, EFT Surge, Conducted Immunity, Dips & Interruptions, Harmonics &Interharmonics) (Cl.19.11.4.1 to 19.11.4.7), Capacitor Test (Cl. 24.1.1), Switching Cycle Operation Test (Cl. 24.1.3), Automatic Control Cycle Operation Test (Cl. 24.1.4), Appliance Coupler and Interconnection (Cl. 24.1.5), Lamp Holder Test (Cl. 24.1.6), Capacitor in Auxillary Winding of Motor Test (Cl. 24.5) and Motors Basic Insulation Test (Cl. 24.6), Components (Cl.24), ], Radiation, Toxicity & Similar Hazards (cl.32)
9 IS 302 : Part 2 : Sec 15 (2009) Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) - - 16838 View breakup
-
Complete 22 May, 2028 -
Restricted to Non Pressure Rice cooker only. EMI/EMC tests (electrostatic Discharges, Radiant Fields, Fast Transient burst, Voltage surges, Injected current, voltage dips & Interruptions, Mains signals) [cl.19.11.4.1 to Cl.19.11.4.7], Radiation, Toxicity & Similar Hazards (cl.32), Components (Cl.24),
10 IS 302 : Part 2 : Sec 6 (2009) Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) - - 23000 View breakup
-
Complete 22 May, 2028 -
[0:26 pm, 24/05/2022] Aslam office: EMI/EMC tests (electrostatic Discharges, Radiant Fields, Fast Transient burst, [0:26 pm, 24/05/2022] Aslam office: Voltage surges, Injected current, voltage dips & Interruptions, Mains signals) [cl.19.11.4.1 to Cl.19.11.4.7], Radiation, Toxicity & Similar Hazards (cl.32), Components (Cl.24), endurance of switches (Cl.24.1.3), endurance of automatic controls (Cl.24.1.4)
11 IS 4250 (1980) Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) - - 20000 View breakup
-
Complete 22 May, 2028 -
EMI/EMC tests (Electrostatic discharges, radiant fields, fast transient bursts, voltage Surges, injected current, voltage dip and interruption, mains signals) (Cl.19.11.4.1 to 19.11.4.7), Radio Intreference Suppression test(Cl.14)'
12 IS 8978 (1992) Specification for electric instantaneous water heaters (Second Revision) - - 19000 View breakup
-
Complete 22 May, 2028 -
Restricted to steel tanks only and with rated pressure upto 1.2MPA EMI/EMC tests (Electrostatic discharges, radiant fields, fast transient bursts, voltage surges, injected current, voltage dip and interruption, mains signals) (Cl.19.11.4.1 to 19.11.4.7)
13 IS 2082 (2018) Stationary storage type electric water heaters - Specification (Fifth Revision) - - 20000 View breakup
-
Complete 22 May, 2028 -
-
14 IS 302 : Part 2 : Sec 35 (2017) Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 35 electric instantaneous water heaters (Second Revision) - - 16613 View breakup
-
Complete 22 May, 2028 -
Restricted to rated pressure upto 1.2MPA. EMI/EMC tests (electrostatic Discharges, Radiant Fields, Fast Transient burst, Voltage surges, Injected current, voltage dips & Interruptions, Mains signals) [cl.19.11.4.1 to Cl.19.11.4.7], Components (Capacitors for radio interference suppression, isolating transformer, coupler) (Cl.24.1.1, 24.1.2, 24.1) Note: Copper purity declared by manufacturer.
15 IS 302 : Part 2 : Sec 26 (2014) Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 26 clocks (First Revision) - - 25000 View breakup
-
Complete 22 May, 2028 -
Cl. 19.11.4.1 to 19.11.4.4 EMI/EMC, Cl. 24 Components, Radiation, Toxicity & Similar Hazards (cl.32)
16 IS 302 : Part 2 : Sec 25 (2014) Safety of household and similar electrical appliances: Part 2 Particular requirements: Section 25 Microwave ovens - - 40000 View breakup
-
Complete 22 May, 2028 -
Cl.19.11.4 EMI/EMC -- Cl.24 Components ( Magnetron, HV transformer capacitor diode, Capacitor and RC units RF Suppression X-Y capacitor, PCB Material, Inductor SMPS Transformer, MOV/VDR, Relays, Power cord, Thermal Cut-out / Thermostat Appliance connector Inlet Door Interlock Switches, IP category, Enclosure insulation material, Bridging resistor)Cyclic(Sodium Chloride solution)
17 IS 302 : Part 2 : Sec 21 (2018) Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 21 stationary storage type electric water heaters (Second Revision) - - 16500 View breakup
-
Complete 22 May, 2028 -
Restricted to rated pressure upto 1.2MPA. EMI/EMC tests (electrostatic Discharges, Radiant Fields, Fast Transient burst, Voltage surges, Injected current, voltage dips & Interruptions, Mains signals) [cl.19.11.4.1 to Cl.19.11.4.7], Radiation, Toxicity & Similar Hazards (cl.32), Components (C1.24) Note: Copper purity declared by manufacturer.
18 IS 368 (2014) Electric immersion water heaters - Specification (Fifth Revision) - - 19000 View breakup
-
Complete 22 May, 2028 -
Restricted Upto 5KW EMI/EMC tests (Electrostatic discharges, radiant fields, fast transient bursts, voltage surges, injected current, voltage dip and interruption, mains signals) (Cl.19.11.4.1 to 19.11.4.7), Components (Capacitors for radio interference suppression, isolating transformer, coupler) (Cl.24.1.1, 24.1.2, 24.1.5)
19 IS 16333 : Part 3 (2017) Mobile phone handsets: Part 3 indian language support for mobile phone handsets - Specific requirements (First Revision) - - 15000 View breakup
-
Complete 22 May, 2028 -
-
20 IS 16103 : Part 1 (2012) Led modules for general lighting: Part 1 safety requirements - - 37500 View breakup
-
Complete 22 May, 2028 -
Components (Cl.102)
21 IS 616 (2017) Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) - - 45000 View breakup
-
Complete 22 May, 2028 -
Ionizing radiation (Cl.6.1), Products other than with laser system class 1 (Cl. 6.2), Light a emitting (6.3), Endurance test for wound components with insulated winding wires without additional interleaved insulation (Cl.8.16), Endurance test for wound components with insulated winding wires without additional interleaved insulation (Cl.8.17), Printed boards (CL.13.5), Enclosed, enveloped or hermetically connected to the mains, clearness and creepage distanced (Cl. 13.7), Components (CL..14.0), 8 Plugs & sockets (Cl. 15.1), terminals for external flexible cords and for permanent connection to the mains supply (Cl 15.3), Mains cords sheathed type, complying with (Cl.16.1), Mechanical strength of Picture tubes & protection against the effect of implosion (Cl.18), Electrical component & mech. Parts (Cl.20.2),Resistors (Cl.14.2), Capacitors & RC units (Cl .14.3), Inductors & windings (Cl.14.4), High voltage components & assemblies (Cl.14.5), Protective devices (Cl.14.6), Thermal releases (14.6.2), Fuse & fuse holder (Cl.14.6.3), PTC thermistor (Cl.14.6.4), Switch (14.7), Batteries (Cl.14.11), Opto coupler (.14.12), Surge suppression varistors (14.13)
22 IS 10322 : Part 5 : Sec 9 (2017) Luminaires: Part 5 particular requirements: Sec 9 rope lights - - 55000 View breakup
-
Complete 22 May, 2028 -
Electrical endurance (CBC) (cl.20.7.4 & Cl.6.14.2 of Annex A), Bendings (Nonrewireable connectors) (cl.20.7.4 & Cl.6.14.3 of Annex A), Control Unit (Cl.20.7.8 & IEC 61347-2-11) IPX8 upto 1.3m
23 IS 10322 : Part 5 : Sec 7 (2017) Luminaires: Part 5 particular requirements: Sec 7 lighting chains (First Revision) - - 55000 View breakup
-
Complete 22 May, 2028 -
[0:22 pm, 24/05/2022] Aslam office: UV Radiations as per C. 4.24 & Annex P of IS 10322 (Part 1):2014, Electrical endurance [0:23 pm, 24/05/2022] Aslam office: (CBC) (cl.20.7.4 & Cl.6.14.2 of Annex A), Bendings (Nonrewireable connectors) (cl.20.7.4 & Cl.6.14.3 of Annex A), Control Unit (Cl.20.7.8 & IEC 61347-2-11) IPX8 upto 1.3m
24 IS 10322 : Part 5 : Sec 6 (2013) Luminaires: Part 5 particular requirements: Sec 6 handlamps - - 55000 View breakup
-
Complete 22 May, 2028 -
UV Radiation for Metal halide lamps (Cl.4.24, Annex-P) IPX8 upto 1.3m
25 IS 10322 : Part 5 : Sec 5 (2013) Luminaires: Part 5 particular requirements: Sec 5 floodlights (First Revision) - - 55000 View breakup
-
Complete 22 May, 2028 -
Luminaries size restricted to 1000 mm for photometric test, UV Radiations as per C. 4 .24 & Annex P of IS 10322 (Part 1):2014, Short-circuit protection as per cl.4.26 IPX8 upto 1.3m
26 IS 10322 : PART 5 : SEC 3 (2012) Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) - - 55000 View breakup
-
Complete 22 May, 2028 -
Luminaries size restricted to 1000 mmfor photometric test, UV Radiations as per C. 4 .24 & Annex P of IS 10322 (Part 1):2014, Short-circuit protection as per cl.4.26 IPX8 upto 1.3m
27 IS 10322 : Part 5 : Sec 2 (2012) Luminaires: Part 5 particular requirements: Sec 2 recessed luminaires (First Revision) - - 55000 View breakup
-
Complete 22 May, 2028 -
Luminaries size restricted to 1000 mm for photometric test, UV Radiations as per C. 4 .24 & Annex P of IS 10322 (Part 1):2014, Short-circuit protection as per cl.4.26 IPX8 upto 1.3m
28 IS 16102 : Part 1 (2012) Self - Ballasted led lamps for general lighting services: Part 1 safety requirements - - 40000 View breakup
-
Complete 22 May, 2028 -
Restricted only to Cap type B22d, E14 & E27
29 IS 366 (1991) Electric iron - Specification (Fourth Revision) - - 15000 View breakup
-
Complete 22 May, 2028 -
Abnormal operation (Cl.19.11.4.1 to 19.11.4.4
30 IS 302 : Part 2 : Sec 3 (2007) Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 3 electric iron (First Revision) - - 12495 View breakup
-
Complete 22 May, 2028 -
Exclusions: EMI/EMC tests (electrostatic Discharges, Radiant Fields, Fast Transient burst, Voltage surges, Injected current, voltage dips & Interruptions, Mains signals) [cl.19.11.4.1 to Cl.19.11.4.7], Radiation, Toxicity & Similar Hazards (cl.32), Components (Cl.24)

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.

Contact for any query/support: supportlims@bis.gov.in