S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Exclusion Testing Charges (Excl. Of Taxes) Facility Type Effective Date Validity Date Remark
31 IS 302 : Part 2 : Sec 201 (2008) Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 201 electric immersion water heaters (First Revision) - - 13969 View breakup
-
Complete 22 May, 2028 -
Restricted Upto 5KW EMI/EMC tests (Electrostatic discharges, radiant fields, fast transient bursts, voltage surges, injected current, voltage dip and interruption, mains signals) (Cl.19.11.4.1 to 19.11.4.7), Components (Capacitors for radio interference suppression, isolating transformer, coupler) (Cl.24.1.1, 24.1.2, 24.1.5) cl.22.16 automatic cord reel, cl 22.32 test on ceramic materials cl.22.46 software
32 IS 16242 : Part 1 (2014) Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS - - 75000 View breakup
-
Complete 22 May, 2028 -
Exclusions: Restricted upto 10Kva Single Phase only. Excluding: Components (Cl.4.5/ RD, CI. 1.5), Winding Wires (Cl. 2.10.5.3), Semiconductor Devices (Cl. 2.10.5.4), SMPS/Main transformer (cl.2.10.5.11); PCB Material (cl.2.10.6); SMPS/ Mains Transformer (Cl. 2.10.5.11), Wire in wound components (Cl. 2.10.5.12), Wire with solvent based enamel in wound components (Cl. 2.10.5.13), Additional insulation in wound components (Cl. 2.10.5.14), Tests for pollution degree 1 environment & for insulating compound (Cl. 2.10.10), Tests for semiconductor devices & for cemented joints (Cl. 2.10.11), Enclosed & sealed parts (Cl. 2.10.12), Internal Wire (Cl. 3.1.4), Batteries (Cl.4.3.8), Non-rewirable Plug with PVC Sheathed Cable (Cl. 3.2.5), Construction of printed circuit boards (Cl.5.7/RD/2.10.6), Wiring, connection and supply (Cl.6.1.1/RD 3.1.4), Batteries (Cl. 4.3.8), Performance Tests: Simulators (ESD/EFT/Voltage Dip Interruption/PFMF), Gas Concentration, Ventilation of Battery Compartments (Cl.7.4.3, Cl.7.6.7 & Annex- M), Non-rewirable plug with PVC sheathed cable (Cl.3.2.5), Performance tests:simulators immunity to Low frequency signals (Annex L.5.2 (IEC 32040-2,CI.7.3)). Switches & Relays (cl.5.6.1 / RD cl.2.8.7); Insulating Conductors (cl.6.1.1/RD cl.3.1.4)
33 IS 15885 : Part 2 : Sec 13 (2012) Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules - - 45000 View breakup
-
Complete 22 May, 2028 -
Components: enclosures (Cl.16), Bridging resistor in primary circuit (Cl.16), capacitor an RC units (Cl.16), RF suppression (X-Y capacitors) (Cl.16), Inductor (Cl.16), MOV/VDR (CI.16), SMPS/Mains Transformer (cl.16); PCB material (cl.16); Metal base PCB for LED (cl.19); Transparent cover (Cl.19), Bobbin (Cl.19), Insulated tape (Cl.16), heat shrinkage cleeve (Cl.16), connector (Cl.16), Fuse (Cl.16), Internal wire (Cl.16), LED (Cl.16), opto-coupler (CI.16), EMI/EMC filter (Cl.16), Winding wire (Cl.16), Thin sheet materials (Cl.16)
34 IS 13252 : Part 1 (2010) Information technology equipment - Safety: Part 1 general requirements (Second Revision) - - 40000 View breakup
-
Complete 22 May, 2028 -
Excluding: Component (Cl.1.5), Moving parts (Cl.2.8.5),Semiconductor devices (Cl.2.10.5.4), Insulation in wound component (Cl.2.10.5.11), Wire in wound component (Cl.2.10.5.12), Wire with solvent based enamel in wound components (Cl.2.10.5.13), Additional insulation in wound components (Cl.2.10.5.14), Test on coated printed boards and coated components (Cl.2.10.8.1), Test for Pollution Degree 1 environment and insulating compound (Cl.2.10.10), Tests for semiconductor devices and for cemented joints(Cl.2.10.11), Enclosed and sealed parts(Cl.2.10.12), Ac power supply cord(Cl.3.2.5.1), High pressure lamps (Cl.4.2.9), Radiation (Cl.4.3.13), Ionizing radiation (Cl.4.3.13.2), Effect of UV radiation on materials (Cl.4.3.13. & Annex Y), Human exposure to UV radiation (Cl.4.3.13.4), Laser including LED (Cl.4.3.13.5), Light emitting diodes (LED's) (Cl.4.3.13.5.2), Materials for air filter assemblies (4.7.3.5), Materials used in high voltage components (4.7.3.6) Electromechanical components (Cl. 5.3.5), Unattended Equipments (Cl.5.3.8) Insulating winding wires (c.2.10.5.2 & Annex U), Evaluation of IC current limiters (Annex CC)
35 IS 10322 : Part 5 : Sec 1 (2012) Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) - - 25000 View breakup
-
Complete 22 May, 2028 -
Linings and Sleeves (Cl. 4.9), UV Radiation (Cl. 4.24 & annex P) Cl. 4.14 Suspensions and adjusting Devices, Electromechanical Contact System (Cl.4.11.6 of IS 10322-1), Short Circuit Protection (Cl.4.26 of IS 10322-1, IPX8 upto 1.3m Luminaries size restricted to 1000 mm, Torque upto 6 Nm for Cl. 4.12.1 of IS 10322(Pt 1): 2014 IPX8 upto 1.3m