61 |
IS 7834 : Part 8 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 8 Specific requirements for caps |
16 To 315 mm |
-
|
5750.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
2.2.2(diameter of the socket of cap) |
- |
500.00 |
|
All dimensions have Single Charge. |
2.1(General) |
- |
5250.00 |
|
1. Stress Relief Test- 700.00
2. Opacity - 700.00
3. Effect on Water- 3000.00
4. Short term Hydraulic - 850.00 |
2.1(General) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2(Manufacture) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2(Manufacture) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2(diameter of the socket of cap) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2 table 1(Laying length) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
|
Complete
|
|
- |
Exclusion: Cl 6.1.1 (VCM Content Test) |
62 |
IS 7834 : Part 7 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 7 Specific requirements for unions |
16 TO 315 MM |
-
|
5750.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
2.2.2, Table 1(Union Laying
Length) |
- |
500.00 |
|
- |
2.2.3( inside diameter of the socket) |
- |
0.00 |
|
All dimensions have single charge. |
2.2.3(Socket length) |
- |
0.00 |
|
All dimensions have single charge. |
2.1(General) |
- |
5250.00 |
|
1. Stress Relief Test- 700.00
2.Opacity - 700.00
3. Effect on water - 3000.00
4. Short term hydraulic - 850.00 |
table 1 sl.no: 01(16
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 02(20
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 03(25
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 04(32
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 05(40
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 06(50
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 07(63
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2(Manufacture) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2, Table 1(Size) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.1(General) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2(Manufacture) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2, Table 1(Size) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2, Table 1(Union Laying
Length) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.3( inside diameter of the socket) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.3(Socket length) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2 table 1(Laying length) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
|
Complete
|
|
- |
Exclusion: Cl 6.1.1 (VCM Content Test) |
63 |
IS 7834 : Part 6 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 6 Specific requirements for sockets |
16 TO 315 MM |
-
|
5750.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
2.2.2, Table 1(Socket Laying
Length) |
- |
500.00 |
|
- |
2.2.3( inside diameter of the socket) |
- |
0.00 |
|
ALL DIMENSION HAVE SINGLE CHARGE. |
2.2.3(Socket length) |
- |
0.00 |
|
ALL DIMENSION HAVE SINGLE CHARGE. |
2.1(General) |
- |
5250.00 |
|
1. STRESS RELIEF TEST- 700.00
2. OPACITY - 700.00
3. EFFECT ON WATER- 3000.00
4. SHORT TERM HYDRAULIC- 850.00 |
table 1 sl.no: 01(16
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 02(20
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 03(25
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 04(32
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 05(40
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 06(50
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 07(63
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 08(75
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 09(90
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 10(110
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 11(125
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 12(140
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 13(160
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 14(
180
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 15(200
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 16(225
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 17(250.0) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 18(280.0) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 19(315.0) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2(Manufacture) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.1(General) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2, Table 1(Size) |
- |
0.00 |
|
- |
2.2(Manufacture) |
- |
0.00 |
|
- |
2.2.2, Table 1(Size) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2, Table 1(Socket Laying
Length) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.3( inside diameter of the socket) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.3(Socket length) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2 table 1(Laying length) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
|
Complete
|
|
- |
Exclusion: Cl 6.1.1 (VCM Content Test) |
64 |
IS 7834 : Part 5 (1987) |
Injection Moulded PVC Socket Fittings With Solvent Cement Joints for Water Supplies - Part 5 : Specific Requirements for 45 degree Tees |
16 TO 315 MM |
-
|
5750.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
2.2.2, Table 1(45 ̊ Tees Laying
Length, Z) |
- |
500.00 |
|
ALL DIMENSION HAVE SINGLE CHARGE. |
2.2.3( inside diameter of the socket) |
- |
0.00 |
|
ALL DIMENSION HAVE SINGLE CHARGE. |
2.2.3(Socket length) |
- |
0.00 |
|
ALL DIMENSION HAVE SINGLE CHARGE. |
2.1(General) |
- |
5250.00 |
|
1. STRESS RELIEF TEST - 700.00
2. OPACITY - 700.00
3. EFFECT ON WATER - 3000.00
4. SHORT TERM HYDRAULIC - 850.00 |
table 1 sl.no: 01(16 (Z)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 02(20 (Z)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 03(25 (Z)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 04(32 (Z)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 05(40 (Z)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 06(50 (Z)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 07(63 (Z)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 08(75 (Z)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 09(90 (Z)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 10(110 (Z)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 11(125 (Z)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 12(140 (Z)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 13(160(z)) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 01(16 (Z1)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 02(20 (Z1)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 03(25 (Z1)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 04(32 (Z1)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 05(40 (Z1)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 06(50 (Z1)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 07(63 (Z1)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 08(75 (Z1)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 09(90 (Z)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 10(110 (Z1)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 11(125 (Z1)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 12(140 (Z1)
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 13(160(z1)) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.1(General) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2(Manufacture) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2, Table 1(Size) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2, Table 1(45 ̊ Tees Laying
Length, Z1) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2(Manufacture) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2, Table 1(Size) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2, Table 1(45 ̊ Tees Laying
Length, Z) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2, Table 1(45 ̊ Tees Laying
Length, Z1) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.3( inside diameter of the socket) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.3(Socket length) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2 table 1(Laying length) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
|
Complete
|
|
- |
Exclusion: Cl 6.1.1 (VCM Content Test) |
65 |
IS 7834 : Part 3 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 3 Specific requirements for 90 degree elbows |
16 TO 315 MM |
-
|
5750.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
cl 2.2.2(Dimensions) |
- |
500.00 |
|
- |
Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Lead (first extraction) - Appendix C ) |
- |
5250.00 |
|
1. STRESS RELIEF TEST- 700.00
2. OPACITY - 700.00
3. EFFECT ON WATER - 3000.00
4. SHORT TERM HYDROSTATIC PRESSURE TEST - 850.00 |
Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Lead (third extraction) - Appendix C) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Dialkyl tin C4 and higher homologues measured as tin (third extraction) - Appendix C) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Other toxic substances (third extraction) - Appendix C) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2 table 1(Laying length) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
|
Complete
|
|
- |
Exclusion: Cl 6.1.1 (VCM Content Test) |
66 |
IS 7834 : Part 2 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 2 Specific requirements for 45 degrees elbows |
16 to 315 mm |
-
|
5750.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
2.1(General) |
- |
4400.00 |
|
Stress Relief Test - 700.00
Opacity - 700.00
Effect on Water - 3000.00 |
2.2.3( inside diameter of the socket) |
- |
500.00 |
|
All the dimension have single charge. |
6.4 PART-1(Short term hydraulic test) |
- |
850.00 |
|
- |
2.1(General) |
- |
0 |
|
- |
table 1 sl.no: 01(16
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 02(20
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 03(25
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 04(32
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 05(40
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 06(50
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 07(63
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 08(75
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 09(90
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 10(110
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 11(125
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 12(140
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 13(160
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 14(
180
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 15(200
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 16(225
) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 17(250.0) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 18(280.0) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
table 1 sl.no: 19(315.0) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2(Manufacture) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2, Table 1(Size) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2, Table 1(45 ̊ Elbow Laying
Length) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.3(socket length) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2(Manufacture) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2, Table 1(Size) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2, Table 1(45 ̊ Elbow Laying
Length) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.3( inside diameter of the socket) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.3(socket length) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
2.2.2 table 1(Laying Length) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
|
Complete
|
|
- |
Exclusion: Cl 6.1.1 (VCM Content Test) |
67 |
IS 7834 : Part 1 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 1 General requirements |
16 to 315 mm |
-
|
5750.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.4(Minimum Thickness) |
- |
0.00 |
|
Thickness & Other dimension Have single Charge |
Cl. 5.1.1, 5.1.2, Table 1, Fig 1(Minimum Socket Length) |
- |
500.00 |
|
- |
Cl. 6.1(Stress Relief Test- Appendix A) |
- |
700.00 |
|
- |
Cl. 6.2(Opacity- Appendix B) |
- |
700.00 |
|
- |
Cl. 6.3(Effect on Water[(Lead ( first extraction )]- Appendix C) |
- |
3000.00 |
|
- |
Cl. 6.4(Short-Term Hydraulic Test- Appendix D) |
- |
850.00 |
|
- |
Cl. 5.1.1, 5.1.2, Table 1, Fig 1(Out-of-roundness tolerances of socket inside diameter) |
- |
0.00 |
|
Thickness & Other dimension Have single Charge |
Cl. 5.1.1, 5.1.2, Table 1, Fig 1(Mean Socket Internal Diameter at Mid-Point of Socket Length) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
Cl. 6.3(Effect on Water[(Lead ( third extraction )]- Appendix C) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
Cl. 6.3(Effect on Water [Dialkyl tin C4, and higher homologues, measured as tin ( third extraction )]- Appendix C) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
Cl. 6.3(Effect on Water [Other toxic substances ( third extraction )]- Appendix C) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
3(Size of Fitting -) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
4(Minimum thickness) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
5(Socket dimensions) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
6.1(Stress Relief Test) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
6.2(Opacity) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
6.3(Effect on Water) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
6.4(Short-Term Hydraulic Test) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
7.2(Production Routine Tests) |
- |
0.00 |
|
- |
|
Complete
|
|
- |
Exclusion: Cl 6.1.1 (VCM Content Test) |
68 |
IS 14887 (2014) |
Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sacks for packaging of 50 kg food grains – Specification (first revision) |
- |
-
|
21430.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(Material Identification) |
- |
1050.00 |
|
Optional (applicable on Raw materials) |
3.2(Tapes – Width and Thickness
( IS 6192/IS 11197)) |
- |
500.00 |
|
Optional (applicable on Tapes) |
3.2(Tapes – Linear Density
(IS 6192/IS 11197)) |
- |
700.00 |
|
Optional (applicable on Tapes) |
3.2(Tapes – Tenacity (IS 6192/IS 11197)) |
- |
1100.00 |
|
Optional (applicable on Tapes) |
3.2(Tapes – Elongation at point of rupture
(IS 6192/IS 11197)) |
- |
0.00 |
|
Optional (applicable on Tapes). Tenacity & elongation have single charge |
3.2(Tapes – Heat Shrinkage (HDPE) (Cl. 3.2 and IS 6192)) |
- |
1700.00 |
|
Optional (applicable on Tapes) |
3.2(Tapes – Colour Fastness for pigmented tapes (IS 6192/IS 11197)) |
- |
19850.00 |
|
Optional (applicable on Tapes)
Test Charge- 850.00
Conditioning Charge- 19000 (Applicable on Pigmented Tapes) |
3.2(Tapes – Dimensional stability (PP)
(IS 11197)) |
- |
1400.00 |
|
Optional (applicable on Tapes) |
3.3.1(Bottom seam (IS 10789)) |
- |
500.00 |
|
- |
4.1 and 3.4(Mass of bale (Cl. 4.1), Capacity (Cl 3.4)) |
- |
500.00 |
|
- |
4.2 and Table 1 ii(Dimensions ) |
- |
500.00 |
|
- |
5.2 and Table 1 iii(Ends per dm ) |
- |
500.00 |
|
- |
5.2 and Table 1 iv(Picks per dm ) |
- |
500.00 |
|
- |
4.2 and Table 1 v(Mass of sack ) |
- |
500.00 |
|
- |
4.2 and Table 1 vi(Average breaking strength of fabric ) |
- |
2200.00 |
|
- |
4.2 and Table 1 vi(Breaking strength of bottom seam ) |
- |
1100.00 |
|
- |
4.2 and Table 1 viii(Elongation at break of fabric ) |
- |
0.00 |
|
Breaking strength & Elongation have single Charge. |
4.2 and Table 1 ix(Average breaking strength and elongation at break of UV stabilized HDPE/PP fabric after been exposed to UV radiation and weathering ) |
- |
12380.00 |
|
1. UV exposure Charge- 10800.00
2. Breaking strength Length wise- 1100.00
3.breaking strength width wise- 1100.00 |
4.2 and Table 1 x(Ash content ) |
- |
1200.00 |
|
- |
3.1(Overall Migration) |
- |
1700.00 |
|
Optional (applicable on raw materials) 1. Sample preparation charge- 625.00 |
3.2(Density) |
- |
700.00 |
|
Optional (applicable on HDPE raw materials) 1. Sample preparation charge- 625.00 |
3.2(MFI) |
- |
1100.00 |
|
Optional (applicable on raw materials) |
3.2(Tapes – Width and Thickness
( IS 6192/IS 11197)) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
3.2(Tapes – Linear Density
(IS 6192/IS 11197)) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
3.2(Tapes – Tenacity (IS 6192/IS 11197)) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
3.2(Tapes – Elongation at point of rupture
(IS 6192/IS 11197)) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
3.2(Tapes – Heat Shrinkage (HDPE) (Cl. 3.2 and IS 6192)) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
3.2(Tapes – Colour Fastness for pigmented tapes (IS 6192/IS 11197)) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
3.2(Tapes – Dimensional stability (PP)
(IS 11197)) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
3.2(Unlaminated Fabric Mass ) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
3.3.1(Bottom seam (IS 10789)) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
4.1 and 3.4(Mass of bale (Cl. 4.1), Capacity (Cl 3.4)) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
4.2 and Table 1 ii(Dimensions ) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
5.2 and Table 1 iii(Ends per dm ) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
5.2 and Table 1 iv(Picks per dm ) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
4.2 and Table 1 v(Mass of sack ) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
4.2 and Table 1 vi(Average breaking strength of fabric ) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
4.2 and Table 1 vi(Breaking strength of bottom seam ) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
4.2 and Table 1 viii(Elongation at break of fabric ) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
4.2 and Table 1 ix(Average breaking strength and elongation at break of UV stabilized HDPE/PP fabric after been exposed to UV radiation and weathering ) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
4.2 and Table 1 x(Ash content ) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
3.2(Unlaminated Fabric Mass ) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
|
Complete
|
|
- |
- |
69 |
IS 12701 (1996) |
Rotational moulded polyethylene water storage tanks - specification (First Revision) |
UPTO 5000 LTR |
-
|
18375.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.2.1(Density) |
- |
700.00 |
|
- |
4.2.2(MFI) |
- |
1100.00 |
|
- |
4.2.3(Carbon Black Content ) |
- |
925.00 |
|
- |
4.2.3(Carbon Dispersion Test) |
- |
700.00 |
|
- |
5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
500.00 |
|
- |
5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
500.00 |
|
- |
5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
500.00 |
|
- |
5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
500.00 |
|
- |
5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
500.00 |
|
- |
5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
500.00 |
|
- |
5.3(Types and Features ) |
- |
500.00 |
|
- |
5.4(Wall Thickness) |
- |
500.00 |
|
- |
5.2 Table 2 (7)(Minimum Wall Thickness) |
- |
500.00 |
|
- |
6.1(Finish) |
- |
500.00 |
|
- |
7.1.1(Resistance to Deformation) |
- |
700.00 |
|
- |
7.2(Resistance to Impact) |
- |
1100.00 |
|
- |
7.3(Test for Top Load Resistance) |
- |
900.00 |
|
- |
7.4(Tensile Strength) |
- |
1800.00 |
|
Test Charge- 1300.00
SAMPLE PREPARATION - 500.00 |
7.5(Flexural Modulus) |
- |
1600.00 |
|
Test Charge- 1100.00
SAMPLE PREPARATION - 500.00 |
7.6(overall Migration) |
- |
2200.00 |
|
Test Charge- 1700.00
SAMPLE PREPARATION - 500.00 |
5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
500.00 |
|
- |
5(Types and Features ) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
5.6(Types and Features ) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
7.1.2(Resistance to Deformation) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
7.6(overall Migration) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
9.2.1(Man-Hole and Hand-Hole Lids) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
9.2(Man-Hole and Hand-Hole Lids) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
9.1(Man-Hole and Hand-Hole Lids) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
9.1(Lid Thickness) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
7.3(Test for Top Load Resistance) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
6.1(Finish) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
5.4(Wall Thickness above effective height) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
5.1 Table 1 (7)(Minimum Weight of Tank (Without Lid)) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
4.1(MATERIALS) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
4.2.1(Density) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
10(MARKING) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
Cl-7.6(Overall Migration) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
4.2.2(MFR) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
|
Complete
|
|
- |
- |
70 |
IS 15328 (2003) |
Unplasticized Non-Pressure Polyvinyl Chloride ( PVC -U ) Pipes for use in Underground Drainage and Sewerage Systems - |
SIZE 110 -315 MM |
-
|
23700.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1,6.1.1
IS 12235 (Part 1)
Table 1(Dimension of Pipes:
Mean outside Diameter, dem) |
- |
500.00 |
|
ALL DIMENSION HAVE SINGLE CHARGE (SOCKET AND PIPE). |
6.1,6.1.1
IS 12235 (Part 1)
Table 1(Outside Diameter at any point, de) |
- |
0.00 |
|
ALL DIMENSION HAVE SINGLE CHARGE (SOCKET AND PIPE). |
6.1.4,
Table 3(Dimensions of integral sockets and spigot ends :-
a) Elastomeric Sealing Ringsockets and
spigot ends
i)Meean inside dia. Of socket, dsm) |
- |
0.00 |
|
ALL DIMENSION HAVE SINGLE CHARGE (SOCKET AND PIPE). |
7.1(Appearance:-
) |
- |
500.00 |
|
- |
7.2(Colour ) |
- |
500.00 |
|
- |
7.3
IS 1223S
( Part 2)(Vicat Softening Temperature
When determined according to IS 1223S
( Part 2), shall not be lessthan 79°C.) |
- |
1100.00 |
|
- |
7.4
IS 1223S ( Part 5)(Longitudinal Reversion:
When tested according to the methodprescribed in IS 1223S ( Part 5), shall not exceed ± 5 percent.
The pipe shall not exhibit any blisters, bubbles or crackson completion of the test.) |
- |
1200.00 |
|
Test Charge- 700.00
SPECIMEN PREPARATION CHARGE- 500.00 |
8.1
Annex B(Resistance to External Blows at 0ºC:
When tested according to the method prescribed in Annex B, the pipes hall have a true impact rate of not more than I0 percent.) |
- |
1600.00 |
|
Test Charge- 1100.00
SPECIMEN PREPARATION CHARGE- 500.00 |
8.2
Annex C
Table 5(Ring Stiffness:
When tested according to the method described in Annex C,the ring stiffness of the pipe shall be as stated in Table 5) |
- |
1600.00 |
|
Test Charge- 1100.00
SPECIMEN PREPARATION CHARGE- 500.00 |
8.3
IS 12235 ( Part 8/ Sec 1 )
Table 6(Resistance to internal Hydrostatic Pressure(Type Test)
a) Acceptance Test:(1h at 27 0 C)
) |
- |
11850.00 |
|
1- TYPE TEST 1000 HOURS- 11000.00
2 - ACCEPTANCE TEST 1 HOURS- 850.00 |
10.1.1
Annex D(Internal hydrostatic pressure test for elastomeric sealing ring joints) |
- |
850.00 |
|
- |
10.2.2(Internal negative hydrostatic pressure test (internal vacuum)for solvent cemented joints) |
- |
1000.00 |
|
- |
6.1.2
IS 4985
Table 2(Wall Thickness, e ) |
- |
0.00 |
|
ALL DIMENSION HAVE SINGLE CHARGE (SOCKET AND PIPE). |
5,5.2(Composition of the material
The material shall contain a minimum of
0.3 percent of rutile grade titanium dioxide.) |
- |
1200.00 |
|
- |
6.1.3 (Length of Pipe) |
- |
0.00 |
|
- |
6.1.4,
Table 3(ii) Min. depth of engagement, A. ) |
- |
0.00 |
|
- |
6.1.4
Table 3(iii) Depth of sealing Zone C ) |
- |
0.00 |
|
- |
6.1.4,
Table 3(iv) Length of spigot, l1) |
- |
0.00 |
|
- |
6.1.4,
Table 3(v) Chamfer length, H : Approx.) |
- |
0.00 |
|
- |
6.1.4.1
(wall thickness of sockets
e2 min=0.9e
) |
- |
0.00 |
|
- |
6.1.4.1
(e3min=0.75e) |
- |
0.00 |
|
- |
6.1.4,
Table 4(b) Solvent Cement Joint sockets and
spigot ends
i) Mean inside dia. Of socket, dsm) |
- |
0.00 |
|
- |
6.1.4,
Table 4(ii) Length of Solvent Cement socket, l2 ) |
- |
0.00 |
|
- |
6.1.4,
Table 4(iii) Length of spigot, l1, 100 mm Min.) |
- |
0.00 |
|
- |
6.1.4,
Table 4(iv) Chamfer length, H, 7 mm Approx.) |
- |
0.00 |
|
- |
7(Physical characteristics
) |
- |
0.00 |
|
- |
7.1(Appearance:-
) |
- |
0.00 |
|
- |
8(MECHANICAL CHARACTERISTICS) |
- |
0.00 |
|
- |
8.3
IS 12235 ( Part 8/ Sec 1 )
Table 6(b) Type Test:(1000h at 60 0 C)
) |
- |
0.00 |
|
- |
9
9.1, IS 5382(JOINTS:-
a) Elastomeric Sealing Rings) |
- |
0.00 |
|
- |
9.2
IS 14182(b) Solvent cement) |
- |
0.00 |
|
- |
10(Performance requirements) |
- |
0.00 |
|
- |
10.1.2
Annex E(Internal negative hydrostatic pressure test (internal vacuum) for elastomeric sealing ring joints) |
- |
0.00 |
|
- |
10.2.1(Internal hydrostatic pressure test for solvent cemented Joints) |
- |
0.00 |
|
- |
'7.5 (amdt.7)(Effect on Water (Type test)) |
- |
0.00 |
|
- |
5.3(Qualitative) |
- |
0.00 |
|
- |
12(Marking) |
- |
0.00 |
|
- |
|
Complete
|
|
- |
- |
71 |
IS 13592 (2013) |
Unplasticized Polyvinyl Chloride (PVC-U) Pipes for Soil and Waste Discharge System Inside and Outside Buiildings Including Ventilation and Rainwater System |
TYPE-A & TYPE B SIZE- 40-315 MM |
-
|
21550.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.5(Surface colour of the pipes shall be dark shade of grey) |
- |
500.00 |
|
- |
Cl6.3(The composition shall be based on PVC resin
having a K-value of 64 or greater when tested in
accordance with IS 4669) |
- |
1100.00 |
|
- |
Cl.7.1(Mean outside diameter, outside diameter at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
500.00 |
|
- |
Cl.7.3.2(Dimensions of sockets for solvent cementing and
grooved sockets of pipes shall be as given in Tables 3
and 4 respectively, read with Fig. 2 and 3.) |
- |
500.00 |
|
- |
Cl.8.1(The internal and external surface of the pipes shall be
smooth and clean, and free from grooving and other
defects. The end shall be clearly cut and shall be square
with the axis of the pipe. The end may be chamfered
on the plain side.) |
- |
500.00 |
|
- |
Cl.8.2(When tested by the method described in IS 12235
(Part 5), a length of pipe sample of 200 ± 20 mm shall
not alter in length by more than 5 percent. In the case
of socket ended pipes, this test shall be carried out on
the plain portion of pipe taken at least 100 mm away
from the root of the socket.) |
- |
1200.00 |
|
Test Charge- 700.00
SPECIMEN PREPARATION CHARGE- 500.00 |
Cl8.3(This test shall be carried out for socket end pipes only.
When tested by the method described in IS 12235
(Part 6), the test specimens shall not show blisters,
excessive delamination or cracking or signs of weld
line splitting.) |
- |
700.00 |
|
- |
Cl.8.4(When determined in accordance with IS 12235 (Part 2),
the vicat softening temperature of the specimen shall
not be less than 79°C.) |
- |
1100.00 |
|
- |
Cl.8.5(After the required
period of exposure, the tensile strengths of two samples when tested as per IS 12235 (Part 13) shall not show
difference of more than 20 percent of their initial tensile
strengths) |
- |
3500.00 |
|
OPTIONAL EFFECT OF SUNLIGH BY XENON ARC FOR 116 HRS. EQUIVALENT TO 16000 HRS GENERAL EXPOSURE- 21800.00
TENSILE STRENGTH AFTER EXPOSURE- 1300 SPECIMEN CHARGE - 500.00 |
Cl. 9, IS 12235 Part 7(Resistance to Sulphuric Acid) |
- |
2500.00 |
|
Test Charge-2000.00
SPECIMEN CHARGE- 500.00 |
Cl.10.1(When tested by method prescribed in IS 12235 (Part 9),the pipe shall have a true impact rate of not more than
10 percent. Mass of striker and height of fall shall be
as per Annex A.) |
- |
1600.00 |
|
Test Charge- 1100.00
SPECIMEN CHARGE- 500.00 |
Cl.10.2(When determined in accordance with the method
described in IS 12235 (Part 13), the tensile strength at
break shall not be less than 45 MPa.) |
- |
1800.00 |
|
Test Charge- 1300.00
SPECIMEN CHARGE- 500.00 |
Cl.11.(Jointing of solvent
cementing joints is to be carried out using solvent
conforming to IS 14182.
Apply a pressure of 0.05 MPa for a period of 15 min
and there should be no leakage at any joint.) |
- |
1000.00 |
|
- |
Cl.10.3(The axial shrinkage shall not exceed 2 percent when
determined in accordance with Annex B.) |
- |
850.00 |
|
- |
8.6(Effect on Water Test) |
- |
3000.00 |
|
- |
Cl. 12, IS 12235 Part 11(Resistance to Di-Chloro-Methane ) |
- |
1000.00 |
|
- |
Cl.7.1( outside diameter at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
Cl.7.1( wall thickness at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
Cl.7.2(Pipes shall be supplied in nominal lengths of 2, 3, 4 or
6 metres either plain or with socket for solvent
cementing/grooved socket. Tolerances on specified
length shall be + 10 mm and – 0 mm.The nominal length of the pipe with socket for solvent
cementing/grooved socket shall be as given in Fig. 1.) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
Cl.7.3.1(Minimum wall thickness of socket on pipes shall
be as given in Table 2 read with Fig. 2 and Fig. 3.) |
- |
0.0 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
14(Marking) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
|
Complete
|
|
- |
- |
72 |
IS 14333 (2022) |
Polyethylene Pipes for Sewerage and Industrial Chemicals and Effluent � Specification (First Revision) |
PE63, PE 80, PE 100 SIZE- 16 TO 315 MM |
-
|
41425.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.2(Colour- IS 14333-2022) |
- |
500.00 |
|
- |
7.1(Visual Appearance- IS 14333-2022) |
- |
500.00 |
|
- |
7.2(Length- IS 14333-2022) |
- |
500.00 |
|
ALL DIMENSION HAVE SINGLE CHARGE- 250.00 |
7.4,T3 of IS 4984(Outside Diameter-IS 4984-2016) |
- |
0.00 |
|
ALL DIMENSION HAVE SINGLE CHARGE- 500.00 |
7.4,T4 of IS 4984(wall Thickness-IS 4984-2016) |
- |
0.00 |
|
ALL DIMENSION HAVE SINGLE CHARGE- 500.00 |
7.4,T3 of IS 4984(Ovality-IS 4984-2016) |
- |
0.00 |
|
ALL DIMENSION HAVE SINGLE CHARGE- 500.00 |
8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 27 oC , Test Period - 100 hrs.-IS 4984-2016 (Annexure-E)) |
- |
4000.00 |
|
- |
8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
1600.00 |
|
- |
8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 165 hrs.-IS 4984-2016 (Annexure-E)) |
- |
4800.00 |
|
- |
8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 1000 hrs.-IS 4984-2016 (Annexure-E)) |
- |
11000.00 |
|
- |
8.1.2, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
1600.00 |
|
- |
8.2("Longitudinal Reversion Test - IS 4984-2016
(Annexure-F)") |
- |
1000.00 |
|
Test Charge- 700.00
SPECIMEN PREPARATION CHARGE- 500.00 |
8.3(Carbon black content- IS 2530-1963) |
- |
925.00 |
|
- |
8.3(Carbon black content Dispersion- IS 2530-1963) |
- |
700.00 |
|
- |
8.4(Melt Flow rate(Temperature - 190oC,Mass 5kg)-IS 2530-1963) |
- |
1100.00 |
|
- |
8.5(Oxidation Induction Time -IS 4984:2016(Annexure-B)) |
- |
2200.00 |
|
- |
8.6(Density-IS 7328:2020) |
- |
700.00 |
|
- |
8.7("Tensile Strength for Butt Fusion - IS 4984-2016
(Annexure-G)") |
- |
1800.00 |
|
Test Charge- 1300.00
SPECIMEN PREPARATION CHARGE- 500.00 |
8.8,T5("Tensile - IS 4984-2016
(Annexure-H)") |
- |
1800.00 |
|
Test Charge- 1300.00
SPECIMEN PREPARATION CHARGE- 500.00 |
8.9(Slow Crack Growth Rate{Internal Pressure creep Rupture test, Temperature - 80±1 oC , Test Pressure – 0.80MPa, Test Period - 500 hrs.-IS 4984-2016 (Annexure-E &J)) |
- |
6000.00 |
|
Test Charge- 5500.00
SPECIMEN PREPARATION CHARGE- 500.00 |
5.2.1,T2("Base Density
(At 27°C Temp.)-IS 7328:2020 ") |
- |
1325.00 |
|
Test Charge- 700.00
SPECIMEN PREPARATION CHARGE- 625.00 |
5.2.1,T2(Melt Flow Rate (At 190°C /5kg)-IS 2530:1963) |
- |
1100.00 |
|
- |
5.2.1,T2(Thermal Stability(Oxidation Induction Time)-IS 4984:2016(Annexure-B)) |
- |
2200.00 |
|
- |
5.2.1,T2("Volatile Matter- IS 4984:2016
(Annexure-C)") |
- |
700.00 |
|
- |
5.2.1,T2("Water Content-IS 4984:2016
(Annexure-D)") |
- |
700.00 |
|
- |
5.2.1.1, T2(Compound Density-IS 7328:2020) |
- |
0.00 |
|
- |
5.2.1.1, T2("Compound carbon black -IS 2530:1963
content") |
- |
0.00 |
|
- |
5.2.1.1, T2(Compound Toluene extract - Any Method) |
- |
0.00 |
|
- |
5.2.1.1, T2(Compound maximum volatile matter -IS 4984:2016 (Annexure-C)) |
- |
0.00 |
|
- |
5.2.1.1, T2(Compound carbon black particle size- Any Method) |
- |
0.00 |
|
- |
5.2.1.1, T2(Compound ash content - Any Method) |
- |
0.00 |
|
- |
5.2.1.1, T2("Compound carbon black -IS 2530:1963
dispersion") |
- |
0.00 |
|
- |
5.3(Density of Higher olefin - IS 7328:2020) |
- |
0.00 |
|
- |
5.3(Olefin Constituents- 14333-2022) |
- |
0.00 |
|
- |
5.3(Loading of Carbon Black - IS 2530:1963) |
- |
0.00 |
|
- |
5.3(Ash content- Any Method) |
- |
0.00 |
|
- |
5.3(Toluene extract - Any Method) |
- |
0.00 |
|
- |
5.3("Maximum volatile matter -IS 4984:2016
(Annexure-C)") |
- |
0.00 |
|
- |
5.3(Carbon black particle size - Any Method) |
- |
0.00 |
|
- |
5.4(Antioxidant - Any Method) |
- |
0.00 |
|
- |
6(Pipe Description - IS 14333-2022) |
- |
0.00 |
|
- |
7.3(Coiling- IS 14333-2022) |
- |
0.00 |
|
- |
8.8,T5("Elongation -IS 4984-2016
(Annexure-H)") |
- |
0.00 |
|
- |
|
Complete
|
|
- |
- |
73 |
IS 4984 (2016) |
Polyethylene pipes for water supply - Specification (Fifth Revision) |
GRADE-PE63,PE80,PE100 SIZE- 16 TO 315 MM |
-
|
44375.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.10(Slow Crack Growth Rate) |
- |
6000.00 |
|
Test Charge-5500.00
SPECIMEN PREPARATION CHARGE- 500.00 |
8.9 table-6(Elongation at Break) |
- |
1800.00 |
|
Test Charge-1300.00
SPECIMEN PREPARATION CHARGE- 500.00 |
8.8(Tensile Strength for Butt-fusion) |
- |
1800.00 |
|
Test Charge-1300.00
SPECIMEN PREPARATION CHARGE- 500.00 |
8.7(Density) |
- |
700.00 |
|
- |
8.5 (Oxidation Induction Time) |
- |
2200.00 |
|
- |
8.4( Melt Flow Rate) |
- |
1100.00 |
|
- |
8.2(Longitudinal Reversion Test) |
- |
1200.00 |
|
Test Charge-700.00
SPECIMEN PREPARATION CHARGE- 500.00 |
8.1.2 table -5(Internal Pressure Creep Rupture Test of Pipe Joints) |
- |
1600.00 |
|
- |
8,/8.1/8.1.1 table-5(PERFORMANCE REQUIREMENTS / Hydraulic Characteristics/ Internal Pressure Creep Rupture Test of Pipe) |
- |
21400.00 |
|
1. 100 HRS.- 4000.00
2.48 HRS.- 1600.00
3.165 HRS.- 4800.00
4. 1000 HRS. - 11000.00
TOTAL 21400.00 |
7.4.1.2(Ovality) |
- |
0.00 |
|
MOD , OVALITY & THICKNESS HAVE SINGLE CHARGE- 500.00 |
7.4 table -3 & 4(6.1 Dimensions) |
- |
750.00 |
|
MOD , OVALITY & THICKNESS HAVE SINGLE CHARGE- 500.00 |
7.2(Length) |
- |
0.00 |
|
- |
6.2.1(6.1.1 Identification Stripes) |
- |
500.00 |
|
DIMENSION OF BLUE STRIPS HAVE ONE CHARGE- 500.00 |
6.2(Colour) |
- |
500.00 |
|
- |
8.6(Overall migration) |
- |
2200.00 |
|
Test Charge-1700.00
SPECIMEN PREPARATION CHARGE- 500.00 |
8.3(Carbon black) |
- |
1625.00 |
|
- |
5.2(Density) |
- |
700.00 |
|
Applicable on Raw material (Optional) |
5.2(Volatile matter Content) |
- |
700.00 |
|
Applicable on Raw material (Optional) |
5.2(MFI @ 1900C/5.0 Kg) |
- |
1100.00 |
|
Applicable on Raw material (Optional) |
Clause 7.1(Visual Apperance) |
- |
500.00 |
|
- |
Table-2 (iii, iv)(Thermal Stability (Oxidation Induction Time), Volatile Matter) |
- |
2200.00 |
|
Applicable on Raw material (Optional) |
Cl. 8.3(Carbon Black Content) |
- |
925.00 |
|
- |
Cl. 8.3(Carbon Black Dispersion) |
- |
700.00 |
|
- |
5.2,T2(Melt Flow rate(Temperature - 190oC,Mass 5kg)-IS 2530-1963) |
- |
1100.00 |
|
Applicable on Raw material (Optional) |
6.1.4(PIPE DESCRIPTION) |
- |
0.00 |
|
- |
6.1.3 (PIPE DESCRIPTION) |
- |
0.00 |
|
- |
6, 6.1.2(PIPE DESCRIPTION) |
- |
0.00 |
|
- |
6, 6.1.1(PIPE DESCRIPTION) |
- |
0.00 |
|
- |
6, 6.1(PIPE DESCRIPTION) |
- |
0.00 |
|
- |
5.4(Anti oxydent) |
- |
0.00 |
|
- |
5.3(e)(Carbon Black Master Batch) |
- |
0.00 |
|
- |
5.3(d)(Carbon Black Master Batch) |
- |
0.00 |
|
- |
5.3(c)(Carbon Black Master Batch) |
- |
0.00 |
|
- |
5.3(b)(Carbon Black Master Batch) |
- |
0.00 |
|
- |
5.3 (a)(Carbon Black Master Batch) |
- |
0.00 |
|
- |
5.2(Polyethylene Resin) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
5, 5.1 table-1(MATERIALS) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
7() |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
5.3(Toluene Extract) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
Clause 7.3(Coiling) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
Clause 8.3(Carbon Black Dispersion) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
Clause 8.3(Carbon Black content) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
Clause 8.6(Overall migration (stimulate)) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
Clause 8.6(Overall migration (surface of material)) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
7.1(Visual Appearance) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
7.3(Coiling) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
8.7(Density-IS 7328:2020) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
8.7(Corrected Density- IS 7328:2020) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
8.9,T6("Tensile - IS 4984-2016
(Annexure-H)") |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
8.9,T6("Elongation -IS 4984-2016
(Annexure-H)") |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
Cl 8.3(Carbon Black Content) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
Cl 8.3(Carbon Black Dispersion) |
- |
0.00 |
|
TEST CHARGES FOR ABOVE PARAMETER ALREADY TAKEN. |
|
Complete
|
|
- |
- |