31 |
IS 204 : Part 2 (1992) |
Tower bolts - Specification: Part 2 non - Ferrous metals (Fifth Revision) |
- |
-
|
3500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 -Table 3- i (Ref. Cl 8, Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - others - IS 504) |
- |
200 |
|
- |
4 -Table 3- i (Ref. Cl 8, Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - Chromium - IS 504) |
- |
200 |
|
- |
4 -Table 3- i (Ref. Cl 8 , Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - Titanium - IS 504) |
- |
200 |
|
- |
4 -Table 3- i (Ref. Cl 8, Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - Zinc - IS 504) |
- |
200 |
|
- |
4 -Table 3- i (Ref. Cl 8, Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - Manganese - IS 504) |
- |
200 |
|
- |
4 -Table 3- i (Ref. Cl 8 , Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - Iron - IS 504) |
- |
200 |
|
- |
4 -Table 3- i (Ref. Cl 8, Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - Silicon - IS 504) |
- |
200 |
|
- |
4 -Table 3- i (Ref. Cl 8, Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - Magnesium - IS 504) |
- |
200 |
|
- |
4 -Table 3- i (Ref. Cl 8 , Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - Copper - IS 504) |
- |
200 |
|
- |
4 -Table 3- i (Ref. Cl 8, Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - Aluminium - IS 504) |
- |
200 |
|
- |
4 -Table 3- ii (Ref. Cl 5.1, Table 1 Designation 65032 of IS 733 : 1983)(Chemical composition - Chromium - IS 504) |
- |
200 |
|
- |
4 -Table 3- ii (Ref. Cl 5.1 , Table 1 Designation 65032 of IS 733 : 1983)(Chemical composition - Titanium and or other grain refining elements - IS 504) |
- |
200 |
|
- |
4 -Table 3- ii (Ref. Cl 5.1 , Table 1 Designation 65032 of IS 733 : 1983)(Chemical composition - Zinc - IS 504) |
- |
200 |
|
- |
4 -Table 3- ii (Ref. Cl 5.1 , Table 1 Designation 65032 of IS 733 : 1983)(Chemical composition - Manganese - IS 504) |
- |
200 |
|
- |
4 -Table 3- ii (Ref. Cl 5.1 , Table 1 Designation 65032 of IS 733 : 1983)(Chemical composition - Iron - IS 504) |
- |
200 |
|
- |
4 -Table 3- ii (Ref. Cl 5.1, Table 1 Designation 65032 of IS 733 : 1983)(Chemical composition - Silicon - IS 504) |
- |
200 |
|
- |
4 -Table 3- ii (Ref. Cl 5.1 , Table 1 Designation 65032 of IS 733 : 1983)(Chemical composition - Magnesium - IS 504) |
- |
200 |
|
- |
4 -Table 3- ii (Ref. Cl 5.1 , Table 1 Designation 65032 of IS 733 : 1983)(Chemical composition - Copper - IS 504) |
- |
200 |
|
- |
4 -Table 3- ii (Ref. Cl 5.1, Table 1 Designation 65032 of IS 733 : 1983)(Chemical composition - Aluminium - IS 504) |
- |
200 |
|
- |
4 -Table 3- iii (Ref. Cl 6.1, Table 1 Designation CuZn40 of IS 410 : 1977)(Chemical composition - Zinc - IS 3635:1966) |
- |
200 |
|
- |
4 -Table 3- iii (Ref. Cl 6.1, Table 1 Designation CuZn40 of IS 410 : 1977)(Chemical composition - Total impurities (including Iron) - IS 3635:1966) |
- |
200 |
|
- |
4 -Table 3- iii (Ref. Cl 6.1, Table 1 Designation CuZn40 of IS 410 : 1977)(Chemical composition - Iron - IS 3635:1966) |
- |
200 |
|
- |
4 -Table 3- iii (Ref. Cl 6.1 , Table 1 Designation CuZn40 of IS 410 : 1977)(Chemical composition - Lead - IS 3635:1966) |
- |
200 |
|
- |
4 -Table 3- iii (Ref. Cl 6.1 , Table 1 Designation CuZn40 of IS 410 : 1977)(Chemical composition - Copper - IS 3635:1966) |
- |
200 |
|
- |
4 -Table 3- iv (Ref. Cl 3.1, Table 1 Grade CB-2 of IS 292 : 1983)(Chemical composition - Zinc - IS 3685:1966) |
- |
200 |
|
- |
4 -Table 3- iv (Ref. Cl 3.1, Table 1 Grade CB-2 of IS 292 : 1983)(Chemical composition - Aluminium - IS 3685:1966) |
- |
200 |
|
- |
4 -Table 3- iv (Ref. Cl 3.1, Table 1 Grade CB-2 of IS 292 : 1983)(Chemical composition - Iron - IS 3685:1966) |
- |
200 |
|
- |
4 -Table 3- iv (Ref. Cl 3.1, Table 1 Grade CB-2 of IS 292 : 1983)(Chemical composition - Tin - IS 3685:1966) |
- |
200 |
|
- |
4 -Table 3- iv (Ref. Cl 3.1, Table 1 Grade CB-2 of IS 292 : 1983)(Chemical composition - Nickel - IS 3685:1966) |
- |
200 |
|
- |
4 -Table 3- iv (Ref. Cl 3.1, Table 1 Grade CB-2 of IS 292 : 1983)(Chemical composition - Copper plus incidental nickel - IS 3685:1966) |
- |
200 |
|
- |
4 -Table 3- v (Ref. Cl 8.1, Table 1 Grade II of IS 319 : 1974)(Chemical composition - Copper - IS 3685:1966) |
- |
200 |
|
- |
4 -Table 3- v (Ref. Cl 8.1, Table 1 Grade II of IS 319 : 1974)(Chemical composition - Lead - IS 3685:1966) |
- |
200 |
|
- |
4 -Table 3- v (Ref. Cl 8.1, Table 1 Grade II of IS 319 : 1974)(Chemical composition - Iron - IS 3685:1966) |
- |
200 |
|
- |
4 -Table 3- v (Ref. Cl 8.1, Table 1 Grade II of IS 319 : 1974)(Chemical composition - Total other impurities excluding iron - IS 3685:1966) |
- |
200 |
|
- |
4 -Table 3- v (Ref. Cl 8.1, Table 1 Grade II of IS 319 : 1974)(Chemical composition - Zinc- IS 3685:1966) |
- |
200 |
|
- |
4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Aluminium- IS 2600:1964) |
- |
200 |
|
- |
4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Magnesium- IS 2600:1964) |
- |
200 |
|
- |
4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Impurities-Copper- IS 2600:1964) |
- |
200 |
|
- |
4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Impurities-Iron- IS 2600:1964) |
- |
200 |
|
- |
4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Impurities-Lead- IS 2600:1964) |
- |
200 |
|
- |
4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Impurities-Cadmium- IS 2600:1964) |
- |
200 |
|
- |
4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Impurities-Tin- IS 2600:1964) |
- |
200 |
|
- |
4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Impurities-Thallium and Indium- IS 2600:1964) |
- |
200 |
|
- |
4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Impurities-Nickel- IS 2600:1964) |
- |
200 |
|
- |
4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Zinc- IS 2600:1964) |
- |
200 |
|
- |
5.1(General) |
- |
1500 |
|
- |
5.2.1 Table 1(Particulars-Barrel Tower Bolts) |
- |
1500 |
|
- |
5.2.2 Table 2(Particulars-Skeleton Tower Bolts) |
- |
1500 |
|
- |
6.1- Table 1(Dimension of Barrel tower bolts-1.Size 2.Length of Bolt or Barrel-(A or B) 4.Width of Barrel-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of Metal of Barrel (Brass or Zink Alloy/Aluminium alloy/Sheet Brass)-F 8.Dia of bore of barrel or socket- G ) |
- |
1500 |
|
- |
6.1- Table 1(Dimension of barrel tower bolts-Minimum No. of equally Spaced holes in Barrel & Socket for wooden screw no 6) |
- |
1500 |
|
- |
6.2- Table 2(Dimension of Skeleton Tower Bolts 1.Size 2.Length of Bolt -A 3.Length of Bolt Plate -B 4.Width of Bolt Plate or Staple-C 5.Dia of Bolt-D 6.Length of Staple-E 7.Thickness of Plate or Socket (Brass /Aluminium alloy or Zink Alloy)-F 8.Dia of bore of Plate or Staple-G 9.Dia of shank of Knob ) |
- |
1500 |
|
- |
6.2- Table 2(Dimension of Skeleton Tower Bolts- Nos of Staples) |
- |
1500 |
|
- |
6.2- Table 2(Dimension of Skeleton Tower Bolts-Minimum No. of Screw holes for wood screw no 4) |
- |
1500 |
|
- |
6.2- Table 3(PACKING) |
- |
0 |
|
- |
7(Finish) |
- |
1500 |
|
- |
8(Packing) |
- |
0 |
|
- |
9(Scale of sampling) |
- |
0 |
|
- |
10(Marking) |
- |
0 |
|
- |
|
Complete
|
|
05 Oct, 2025 |
- Included w.e.f. 07.12.2023. Restriction: Size 75-900 mm, Type 1,2,3,4,5,6,7,8,9 ; Barrel and towel bolts |
32 |
IS 2347 (2023) |
DOMESTIC PRESSURE COOKER � SPECIFICATION |
- |
-
|
35000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(Gross capacity) |
- |
1500 |
|
- |
4.2(Body Capacity) |
- |
1500 |
|
- |
5.1(Body, Lid, Containers and Grid) |
- |
1500 |
|
- |
5.1.2(Body and Lid ) |
- |
1500 |
|
- |
5.1.3(Stainless steel pressure cooker) |
- |
5000 |
|
- |
5.1.4(Aluminium cooker ) |
- |
5000 |
|
- |
5.3(Gasket) |
- |
7000 |
|
- |
5.4(Handles and Knobs) |
- |
15000 |
|
- |
5.5(Pressure Regulating Device ) |
- |
2000 |
|
- |
5.6(Vent Seal Pin for Pressure Regulating Device ) |
- |
2000 |
|
- |
5.7(Vent Pipe ) |
- |
2000 |
|
- |
5.8(Vent Pipe Nut ) |
- |
2000 |
|
- |
5.9(Spring ) |
- |
200 |
|
- |
5.1(Material of Rim ) |
- |
2000 |
|
- |
5.11(Visual Pressure Indicator) |
- |
3000 |
|
- |
5.12(Gasket Release System) |
- |
3000 |
|
- |
6(Construction) |
- |
5000 |
|
- |
7(Workmanship and Finish ) |
- |
5000 |
|
- |
8.1(Air Pressure Test ) |
- |
5000 |
|
- |
8.2(Proof Pressure Test ) |
- |
5000 |
|
- |
8.3(Operating Test for Pressure Regulating Device ) |
- |
5000 |
|
- |
8.4(Test for Safety Relief Device ) |
- |
5000 |
|
- |
8.5(Bursting Pressure Test ) |
- |
5000 |
|
- |
8.6(Test for Removal of Lid under Pressure ) |
- |
5000 |
|
- |
8.7(Test for Spring Loaded Mechanism ) |
- |
5000 |
|
- |
8.8(Composite Cooker Base ) |
- |
5000 |
|
- |
8.9(Aluminium induction compatible Base ) |
- |
5000 |
|
- |
8.1(Handles of cooker ) |
- |
5000 |
|
- |
8.11(External Coating) |
- |
5000 |
|
- |
8.12(Internal Coating ) |
- |
5000 |
|
- |
8.13(Integral electrical heating) |
- |
7500 |
|
- |
8.14(Ply construction cooker Body ) |
- |
7500 |
|
- |
8.15.1(Fragmentation Test ) |
- |
1000 |
|
- |
8.15.2(Ball Drop Test ) |
- |
1000 |
|
- |
8.15.3(Thermal Shock Test ) |
- |
2000 |
|
- |
8.15.4(Free Fall Test) |
- |
2000 |
|
- |
8.17(Test for Effectiveness for Induction Bottom) |
- |
2500 |
|
- |
11(Marking ) |
- |
100 |
|
- |
12(Packing ) |
- |
100 |
|
- |
5.2(Safety Relief Device) |
- |
2500 |
|
- |
|
Complete
|
|
05 Oct, 2025 |
- Included w.e.f. 07.12.2023. Restriction: 1-24 Litre |
33 |
IS 204 : Part 1 (1991) |
Tower bolts - Specification: Part 1 ferrous metals (Fifth Revision) |
- |
-
|
3000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017)(Chemical composition - Carbon - IS 228) |
- |
500 |
|
- |
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017)(Chemical composition - Manganese - IS 228) |
- |
200 |
|
- |
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017)(Chemical composition - Phosphorus - IS 228) |
- |
200 |
|
- |
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017)(Chemical composition - Sulphur - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Carbon - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Manganese - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Sulphur - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Phosphorus - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Silicon - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Carbon Equivalen(CE) - IS 228) |
- |
200 |
|
- |
4 -Table 5- iii (Ref. Cl 6.1 of IS 210 : 2009)(Chemical composition - Sulphur and/or Phosphorous) |
- |
200 |
|
- |
4 -Table 5- iii (Ref. Cl 9.1 of IS 210 : 2009)(The microstructure shall be substantially free of primary cementite and/ or massive stead ite and shall consist oftlake graphite
in a matrix offerrite or pearlite or mixture thereof.) |
- |
200 |
|
- |
4 -Table 5- iii (Ref. Cl 9.1.1 of IS 210 : 2009)(Graphite structute Distribution - IS 7754) |
- |
200 |
|
- |
5.1(General) |
- |
500 |
|
- |
5.2.1 Table 1(Particulars-Barrel Tower Bolts) |
- |
500 |
|
- |
5.2.2 Table 2(Particulars-Sami Barrel Tower Bolts) |
- |
500 |
|
- |
5.2.3 Table 3(Particulars-Riveted or Spot Welded Tower Bolts) |
- |
500 |
|
- |
5.2.4 Table 4(Particulars-Skeleton Tower Bolts) |
- |
500 |
|
- |
6.1- Table 1(Dimension of Barrel tower bolts-1.Size 2.Length of Bolt-A 3.Length of Barrel-B 4.Width of Barrel-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of mild steel sheet for barrel-F 8.Dia of bore of barrel or socket- G ) |
- |
500 |
|
- |
6.1- Table 1(Dimension of Barrel tower bolts-Minimum No. of equally Spaced Screw holes in Barrel and Socket for wood screw no 6) |
- |
500 |
|
- |
6.2- Table 2(Dimension of Sami Barrel Tower Bolts 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of Bolt Plate or Socket-F 8.Dia of bore of Bolt Plate or socket G ) |
- |
500 |
|
- |
6.2- Table 2(Dimension of Sami Barrel Tower Bolts-Minimum No. of equally Spaced Screw holes in Bolt Plate and Socket for wood screw no 6) |
- |
500 |
|
- |
6.3- Table 3(Dimension of Riveted or Spot Welded Tower Bolts- 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Socket-E 7. Length of Strap-E" 8.Thickness of Back Plate -F 9.Thickness of Socket or Upper Plate and Strap- F" 10.Dia of bore of Bolt Plate or socket- G 11. Length of Alternative Socket-H ) |
- |
500 |
|
- |
6.3- Table 3(Dimension of Riveted or Spot Welded Tower Bolts-Minimum No. of equally Spaced Screw holes in Bolt Plate and Socket for wood screw no 6) |
- |
500 |
|
- |
6.4- Table 4(Dimension of Skeleton Tower Bolts 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Staple-E 7.Thickness of Plate or Staple -F 8.Dia of bore of Plate or Staple-G 9.Dia of shank of Knob-J) |
- |
500 |
|
- |
6.4- Table 4(Dimension of Skeleton Tower Bolts- Nos of Staples) |
- |
500 |
|
- |
6.4- Table 4(Dimension of Skeleton Tower Bolts-Minimum No. of Screw holes for wood screw no 6) |
- |
500 |
|
- |
8.1(MARKING- .) |
- |
0 |
|
- |
8.1.1,(MARKING- ) |
- |
0 |
|
- |
9(PACKING) |
- |
0 |
|
- |
7(Finish) |
- |
500 |
|
- |
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017)(Chemical composition - Carbon - IS 228) |
- |
200 |
|
- |
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017)(Chemical composition - Manganese - IS 228) |
- |
200 |
|
- |
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017)(Chemical composition - Phosphorus - IS 228) |
- |
200 |
|
- |
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017)(Chemical composition - Sulphur - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Carbon - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Manganese - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Sulphur - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Phosphorus - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Silicon - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Carbon Equivalen(CE) - IS 228) |
- |
200 |
|
- |
4 -Table 5- iii (Ref. Cl 6.1 of IS 210 : 2009)(Chemical composition - Sulphur and/or Phosphorous) |
- |
200 |
|
- |
4 -Table 5- iii (Ref. Cl 9.1 of IS 210 : 2009)(The microstructure shall be substantially free of primary cementite and/ or massive stead ite and shall consist oftlake graphite
in a matrix offerrite or pearlite or mixture thereof.) |
- |
0 |
|
- |
4 -Table 5- iii (Ref. Cl 9.1.1 of IS 210 : 2009)(Graphite structute Distribution - IS 7754) |
- |
0 |
|
- |
5.1(General) |
- |
200 |
|
- |
5.2.1 Table 1(Particulars-Barrel Tower Bolts) |
- |
200 |
|
- |
5.2.2 Table 2(Particulars-Sami Barrel Tower Bolts) |
- |
200 |
|
- |
5.2.3 Table 3(Particulars-Riveted or Spot Welded Tower Bolts) |
- |
200 |
|
- |
5.2.4 Table 4(Particulars-Skeleton Tower Bolts) |
- |
200 |
|
- |
6.1- Table 1(Dimension of Barrel tower bolts-1.Size 2.Length of Bolt-A 3.Length of Barrel-B 4.Width of Barrel-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of mild steel sheet for barrel-F 8.Dia of bore of barrel or socket- G ) |
- |
200 |
|
- |
6.1- Table 1(Dimension of Barrel tower bolts-Minimum No. of equally Spaced Screw holes in Barrel and Socket for wood screw no 6) |
- |
200 |
|
- |
6.2- Table 2(Dimension of Sami Barrel Tower Bolts 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of Bolt Plate or Socket-F 8.Dia of bore of Bolt Plate or socket G ) |
- |
200 |
|
- |
6.2- Table 2(Dimension of Sami Barrel Tower Bolts-Minimum No. of equally Spaced Screw holes in Bolt Plate and Socket for wood screw no 6) |
- |
200 |
|
- |
6.3- Table 3(Dimension of Riveted or Spot Welded Tower Bolts- 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Socket-E 7. Length of Strap-E" 8.Thickness of Back Plate -F 9.Thickness of Socket or Upper Plate and Strap- F" 10.Dia of bore of Bolt Plate or socket- G 11. Length of Alternative Socket-H ) |
- |
200 |
|
- |
6.3- Table 3(Dimension of Riveted or Spot Welded Tower Bolts-Minimum No. of equally Spaced Screw holes in Bolt Plate and Socket for wood screw no 6) |
- |
200 |
|
- |
6.4- Table 4(Dimension of Skeleton Tower Bolts 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Staple-E 7.Thickness of Plate or Staple -F 8.Dia of bore of Plate or Staple-G 9.Dia of shank of Knob-J) |
- |
200 |
|
- |
6.4- Table 4(Dimension of Skeleton Tower Bolts- Nos of Staples) |
- |
200 |
|
- |
6.4- Table 4(Dimension of Skeleton Tower Bolts-Minimum No. of Screw holes for wood screw no 6) |
- |
200 |
|
- |
8.1(MARKING- .) |
- |
0 |
|
- |
8.1.1,(MARKING- ) |
- |
0 |
|
- |
9(PACKING) |
- |
0 |
|
- |
7(Finish) |
- |
500 |
|
- |
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017)(Chemical composition - Carbon - IS 228) |
- |
200 |
|
- |
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017)(Chemical composition - Manganese - IS 228) |
- |
200 |
|
- |
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017)(Chemical composition - Phosphorus - IS 228) |
- |
200 |
|
- |
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017)(Chemical composition - Sulphur - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Carbon - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Manganese - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Sulphur - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Phosphorus - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Silicon - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Carbon Equivalen(CE) - IS 228) |
- |
200 |
|
- |
4 -Table 5- iii (Ref. Cl 6.1 of IS 210 : 2009)(Chemical composition - Sulphur and/or Phosphorous) |
- |
200 |
|
- |
4 -Table 5- iii (Ref. Cl 9.1 of IS 210 : 2009)(The microstructure shall be substantially free of primary cementite and/ or massive stead ite and shall consist oftlake graphite
in a matrix offerrite or pearlite or mixture thereof.) |
- |
200 |
|
- |
4 -Table 5- iii (Ref. Cl 9.1.1 of IS 210 : 2009)(Graphite structute Distribution - IS 7754) |
- |
200 |
|
- |
5.1(General) |
- |
200 |
|
- |
5.2.1 Table 1(Particulars-Barrel Tower Bolts) |
- |
500 |
|
- |
5.2.2 Table 2(Particulars-Sami Barrel Tower Bolts) |
- |
500 |
|
- |
5.2.3 Table 3(Particulars-Riveted or Spot Welded Tower Bolts) |
- |
500 |
|
- |
5.2.4 Table 4(Particulars-Skeleton Tower Bolts) |
- |
500 |
|
- |
6.1- Table 1(Dimension of Barrel tower bolts-1.Size 2.Length of Bolt-A 3.Length of Barrel-B 4.Width of Barrel-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of mild steel sheet for barrel-F 8.Dia of bore of barrel or socket- G ) |
- |
500 |
|
- |
6.1- Table 1(Dimension of Barrel tower bolts-Minimum No. of equally Spaced Screw holes in Barrel and Socket for wood screw no 6) |
- |
500 |
|
- |
6.2- Table 2(Dimension of Sami Barrel Tower Bolts 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of Bolt Plate or Socket-F 8.Dia of bore of Bolt Plate or socket G ) |
- |
500 |
|
- |
6.2- Table 2(Dimension of Sami Barrel Tower Bolts-Minimum No. of equally Spaced Screw holes in Bolt Plate and Socket for wood screw no 6) |
- |
500 |
|
- |
6.3- Table 3(Dimension of Riveted or Spot Welded Tower Bolts- 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Socket-E 7. Length of Strap-E" 8.Thickness of Back Plate -F 9.Thickness of Socket or Upper Plate and Strap- F" 10.Dia of bore of Bolt Plate or socket- G 11. Length of Alternative Socket-H ) |
- |
500 |
|
- |
6.3- Table 3(Dimension of Riveted or Spot Welded Tower Bolts-Minimum No. of equally Spaced Screw holes in Bolt Plate and Socket for wood screw no 6) |
- |
500 |
|
- |
6.4- Table 4(Dimension of Skeleton Tower Bolts 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Staple-E 7.Thickness of Plate or Staple -F 8.Dia of bore of Plate or Staple-G 9.Dia of shank of Knob-J) |
- |
500 |
|
- |
6.4- Table 4(Dimension of Skeleton Tower Bolts- Nos of Staples) |
- |
500 |
|
- |
6.4- Table 4(Dimension of Skeleton Tower Bolts-Minimum No. of Screw holes for wood screw no 6) |
- |
500 |
|
- |
8.1(MARKING- .) |
- |
0 |
|
- |
8.1.1,(MARKING- ) |
- |
0 |
|
- |
9(PACKING) |
- |
0 |
|
- |
7(Finish) |
- |
500 |
|
- |
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017)(Chemical composition - Carbon - IS 228) |
- |
200 |
|
- |
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017)(Chemical composition - Manganese - IS 228) |
- |
200 |
|
- |
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017)(Chemical composition - Phosphorus - IS 228) |
- |
200 |
|
- |
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017)(Chemical composition - Sulphur - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Carbon - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Manganese - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Sulphur - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Phosphorus - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Silicon - IS 228) |
- |
200 |
|
- |
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011)(Chemical composition - Carbon Equivalen(CE) - IS 228) |
- |
200 |
|
- |
4 -Table 5- iii (Ref. Cl 6.1 of IS 210 : 2009)(Chemical composition - Sulphur and/or Phosphorous) |
- |
200 |
|
- |
4 -Table 5- iii (Ref. Cl 9.1 of IS 210 : 2009)(The microstructure shall be substantially free of primary cementite and/ or massive stead ite and shall consist oftlake graphite
in a matrix offerrite or pearlite or mixture thereof.) |
- |
0 |
|
- |
4 -Table 5- iii (Ref. Cl 9.1.1 of IS 210 : 2009)(Graphite structute Distribution - IS 7754) |
- |
0 |
|
- |
5.1(General) |
- |
500 |
|
- |
5.2.1 Table 1(Particulars-Barrel Tower Bolts) |
- |
500 |
|
- |
5.2.2 Table 2(Particulars-Sami Barrel Tower Bolts) |
- |
500 |
|
- |
5.2.3 Table 3(Particulars-Riveted or Spot Welded Tower Bolts) |
- |
500 |
|
- |
5.2.4 Table 4(Particulars-Skeleton Tower Bolts) |
- |
500 |
|
- |
6.1- Table 1(Dimension of Barrel tower bolts-1.Size 2.Length of Bolt-A 3.Length of Barrel-B 4.Width of Barrel-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of mild steel sheet for barrel-F 8.Dia of bore of barrel or socket- G ) |
- |
500 |
|
- |
6.1- Table 1(Dimension of Barrel tower bolts-Minimum No. of equally Spaced Screw holes in Barrel and Socket for wood screw no 6) |
- |
500 |
|
- |
6.2- Table 2(Dimension of Sami Barrel Tower Bolts 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of Bolt Plate or Socket-F 8.Dia of bore of Bolt Plate or socket G ) |
- |
500 |
|
- |
6.2- Table 2(Dimension of Sami Barrel Tower Bolts-Minimum No. of equally Spaced Screw holes in Bolt Plate and Socket for wood screw no 6) |
- |
500 |
|
- |
6.3- Table 3(Dimension of Riveted or Spot Welded Tower Bolts- 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Socket-E 7. Length of Strap-E" 8.Thickness of Back Plate -F 9.Thickness of Socket or Upper Plate and Strap- F" 10.Dia of bore of Bolt Plate or socket- G 11. Length of Alternative Socket-H ) |
- |
500 |
|
- |
6.3- Table 3(Dimension of Riveted or Spot Welded Tower Bolts-Minimum No. of equally Spaced Screw holes in Bolt Plate and Socket for wood screw no 6) |
- |
500 |
|
- |
6.4- Table 4(Dimension of Skeleton Tower Bolts 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Staple-E 7.Thickness of Plate or Staple -F 8.Dia of bore of Plate or Staple-G 9.Dia of shank of Knob-J) |
- |
500 |
|
- |
6.4- Table 4(Dimension of Skeleton Tower Bolts- Nos of Staples) |
- |
500 |
|
- |
6.4- Table 4(Dimension of Skeleton Tower Bolts-Minimum No. of Screw holes for wood screw no 6) |
- |
500 |
|
- |
8.1(MARKING- .) |
- |
0 |
|
- |
8.1.1,(MARKING- ) |
- |
0 |
|
- |
9(PACKING) |
- |
0 |
|
- |
7(Finish) |
- |
500 |
|
- |
|
Complete
|
|
05 Oct, 2025 |
- Included w.e.f. 07.12.2023. Restriction: size 75-900 mm, Type 1 A to 5 |
34 |
IS/ISO 22702 (2018) |
Utility lighters Safety specifications First Revision |
- |
-
|
80000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(Flame generation) |
- |
5000 |
|
- |
4.2(Flame heights) |
- |
5000 |
|
- |
4.3(Flame- height adjustment) |
- |
2500 |
|
- |
4.4("Resistance to Spitting or
Sputtering and flaring") |
- |
2500 |
|
- |
4.5(Flame extinction) |
- |
5000 |
|
- |
4.6(Volumetric Displacement) |
- |
30000 |
|
- |
5.2(Resistance to dropping) |
- |
5000 |
|
- |
5.3(Resistance to elevated temperature) |
- |
10000 |
|
- |
5.4(Burning behavior) |
- |
5000 |
|
- |
5.5(Resistance to continuous burn) |
- |
5000 |
|
- |
5.6(Resistance to cyclic burn) |
- |
2500 |
|
- |
5.7(External Finish) |
- |
25000 |
|
- |
5.8(Compatibility with fuel) |
- |
5000 |
|
- |
5.9(Resistance to internal pressure) |
- |
5000 |
|
- |
6(Refilling Test) |
- |
5000 |
|
- |
|
Complete
|
|
05 Oct, 2025 |
- Included w.e.f. 07.12.2023. |
35 |
IS 17150 (2019) |
Mini domestic water heater for use with piped natural gas (PNG) ? specification |
- |
-
|
30000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(The construction of all the parts of equipment shall be sound and of high standard of workmanship and appropriate finish. The construction shall ensure durability and shall comply with the safety requirements.) |
- |
200 |
|
NA |
4.1(Rivets, Fastening screws and plugs , etc. shall not lead into gas passages.) |
- |
200 |
|
NA |
4.1.1(No PNG regulator shall be included as a part of the instantaneous domestic gas water heater.) |
- |
200 |
|
NA |
4.1.2(All parts in contact with water shall be made of such a material that shall not pollute water.) |
- |
200 |
|
NA |
4.1.3(All Parts shall be made and so assembled that the performance characteristics of the appliance will not alter significantly during reasonable life and in normal conditions of installation and use.) |
- |
200 |
|
NA |
4.1.4(it shall be possible to clean without difficulty) |
- |
200 |
|
NA |
4.1.5(It shall not be possible to replace to replace parts, which are removable for maintenance in a way that could impair the safe performance of the appliance.) |
- |
200 |
|
NA |
4.1.6(The gas and water soundness shall be assured after reassemble maintenance.) |
- |
200 |
|
NA |
4.1.7(it shall be possible to install an appliance intended to be fixed to a wall with appropriate means of fixing, such as clamps, hooks, Screws, etc. ) |
- |
200 |
|
NA |
4.1.8(All parts of gas water heaters subject to direct heat shall have brazed or welded joints.) |
- |
200 |
|
NA |
4.1.8(Interior surfaces shall be of such material or so protected, so as to avoid contamination of the contents.) |
- |
200 |
|
NA |
4.1.9(The gas (heat) input to the pilot alone shall not exceed 8 l/h at a gas inlet pressure of 21 mbar and at temperature 25-30°C, wherever applicable.) |
- |
200 |
|
NA |
4.1.10(The Appliance shall be provided with a safety device, which cuts off the supply of gas in case water dose not flow or stops flowing while in operation.) |
- |
200 |
|
NA |
4.1.11(The water heater shall have a provision such that supply of gas shall be cut off and the burner extinguished after 20+1/-2 min of uninterrupted use. The appliance shall able to restart manually.) |
- |
200 |
|
NA |
4.1.12(All heat exchanger tubes through which the water passes and water chamber, if provided, shall be completely filled with water before igniting the burner.) |
- |
200 |
|
NA |
5.1(The material used in the construction of the water heater shall be resistant to wear and deterioration occuring in the normal use.) |
- |
500 |
|
NA |
5.2(The copper and copper alloy forged and cast parts shall pass the mercurous nitrate test (Season cracking test) when tested according to the method specified in IS:2305.) |
- |
500 |
|
NA |
5.3(Change in weight or volume of a non metallic material, when immerse in n-Pentane for 72 hours) |
- |
500 |
|
NA |
5.4(Melting point of metal for burner top) |
- |
500 |
|
NA |
5.5(Diaphragm if provided for inlet water control device, shall be made of synthetic rubber.while choosing the material, the manufacturer shall take into account the characteristics required for the satisfactory use that is , mechanical and chemical stability. Material selected shall not degrade under normal working conditions.) |
- |
500 |
|
NA |
6.1(For connections and screws other than for water, metric threads shall be used. ) |
- |
500 |
|
NA |
6.2(Gas inlet connection shall permit a rigid connection.) |
- |
500 |
|
NA |
6.2(Gas inlet connection shall permit a rigid connection.) |
- |
500 |
|
NA |
6.3(All water connection shall be of copper or brass tube and have at least 6 mm inner diameter and 0.5 mm nominal wall thickness of the tube.) |
- |
500 |
|
NA |
6.4(The water inlet and outlet connection shall be of 1/2" BSP thread.) |
- |
500 |
|
NA |
6.5(The gas and water connections shall be situated at the base of the appliance. it shall be possible to connect the appliance to supply, which are in a plane parallel or perpendicular to the wall on which the appliance is fixed.) |
- |
500 |
|
NA |
6.6(Gas Inlet Connections : The water heater shall be provided with nozzle or screwed gas inlet connection as given in 18 of IS:5116) |
- |
500 |
|
NA |
7(All Appliances shall be designed so that ignition, correct burner performance and the length of the pilot flames. If any , can always be easily seen. This visibility shall be assumed at all times and particularly, where there is a viewing window, this shall not deteriorate under the effect of heat.) |
- |
1000 |
|
NA |
8(The Appliance shall have a device allowing manual interruption of the supply of gas to the burner and pilot, if available in case of exigency.) |
- |
500 |
|
NA |
8(The device shall be of such a design that gas shall not enter to the main burner and the pilot (if provided) until it is reset to the original position.) |
- |
500 |
|
NA |
9.1(The Appliance shall have a flame failure device, controlling the admission of gas to the main burner and possibly to any ignition pilot. The provisions given in 14.1 of IS:5116 shall apply.) |
- |
1000 |
|
NA |
10(An appliance shall have an ignition device, where the appliance is provided in the form of a pilot it shall be possible to light it easily with a matchstick or a special ignition device) |
- |
500 |
|
NA |
10(The pilot shall be positioned in such a way that their products of combustion are evacuated with those of the burner) |
- |
500 |
|
NA |
10(While in operation the relative position of the pilot and burner shall not alter.) |
- |
500 |
|
NA |
10(The pilot burner shall be made of a material that shall not deteriorate under normal condition of use) |
- |
500 |
|
NA |
10(It is essential that the pilot flame shall be seen either directly or by reflection.) |
- |
500 |
|
NA |
10(The ignition to the burners from pilot shall be smooth) |
- |
500 |
|
NA |
11(The Water heater shall be provided with a suitable overheat protection device, which shall switch off the supply of gas, if the temperature of the delivered water reaches 80°C max. ) |
- |
1000 |
|
NA |
11(The gas supply shall be restored manually.) |
- |
1000 |
|
NA |
12(The Appliance shall be provided with a means of adjusting water rate.) |
- |
1000 |
|
NA |
14(All gas carrying parts of the appliances should be sound and these parts when connected to form complete assembly shall also be sound against any gas leakage. The complete assembly shall be checked at 14.71 kN/m²) |
- |
1000 |
|
NA |
15(All water carrying parts of the appliance, individually and when assembled to form the water circuit of the appliance shall not leak or show any permanent distortion during or after the test when tested at a hydrostatic pressure 4 kgf/cm2) |
- |
500 |
|
NA |
15(The later circuit shall be kept under pressure for minimum 5 min.) |
- |
500 |
|
NA |
16(Thermal efficiency of Water Heater shall not be less nthan 62%) |
- |
1000 |
|
NA |
17(Ratio of Carbon Monoxide to Carbon Dioxide) |
- |
1000 |
|
NA |
18( (D = Declared Value, Gas Consumption) |
- |
1000 |
|
NA |
19.1(There shall be easy and safe access of lighting each burner by matchstick and it shall be easy to see that the burner is lighted) |
- |
400 |
|
NA |
19.2(if the flame is applied to any one burner pors when the gas is flowing , flame travel shall be complete. This applies for all pressures from 20 to 25 gf/cm² taps being fully open.) |
- |
400 |
|
NA |
19.3(if the burner is ignited from a pilot flame , ignition shall be smooth at pressure from 20-25 gf/cm² with the tap turned full on and ignition shall be effected without delay after turning on the taps.) |
- |
200 |
|
NA |
20(It shall be possible to operate the appliance with taps fully open at gas inlet pressure , without the flame extinguishing, blowing off or striking back and without the formation of soot.) |
- |
500 |
|
NA |
20(Pilot Flame shall be Stable without lifting or soot deposition at gas inlet pressure from 20-25 gf/cm2) |
- |
500 |
|
NA |
21(Ignition of Burner flame, their operation and turning off shall not give rise to undue excessive noise during the operation.) |
- |
1000 |
|
NA |
22(While the appliance is in operation at full gas consumption and the appliance is in thermal equilibrium, the flame shall be immediately reduced to the minimum possible and then brought back to the full size, the operation shall be repeated five times, no flash back shall occur during the test, applicable for pressure 20-25 gf/cm².) |
- |
1000 |
|
NA |
23(There shall be no extinction of flame on any of the burner operating at the maximum consumption when the appliance is placed in a normal current of air with velocity of 2 m/s as measured with a rotating vane anemometer. The location of the appliance relative to the neighbouring walls and the direction of the draught shall be varied to correspond to likely conditions of appliance installation, applicable for all pressure 20-25 gf/cm².) |
- |
1000 |
|
NA |
24(Wall, Floor, Ceiling temperatures: Rise of Temperature above room temperature in , after two hours of operation) |
- |
250 |
|
NA |
24(Surface temperature:Temperature of the portion of the surface other than the working surface likely to be touched accidentally.) |
- |
250 |
|
NA |
24(Temperature of the surface in normal use) |
- |
250 |
|
NA |
24(Temperature of synthetic rubber diaphragm in gas carrying components) |
- |
250 |
|
NA |
25(When tested as per annex D, at the nominal gas rate with the appliance adjusted to give a temperature rise of 45±5°C between the water inlet and outlet , the time to achieve 90% of this temperature rise-) |
- |
1000 |
|
NA |
26(Hot water output, Declared Value) |
- |
1000 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- - |
36 |
IS 14756 (2022) |
Draft Indian Standard STAINLESS STEEL COOKWARE SPECIFICATION Second Revision of IS 14756 |
- |
-
|
15000 View breakup
Composite bottom – Rs. 15000/-
Other utensils – Rs. 10000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1 & Table 1 of IS 5522 (Carbon) |
- |
500 |
|
NA |
3.1 & Table 1 of IS 5522 (Silicon) |
- |
500 |
|
NA |
3.1 & Table 1 of IS 5522 (Manganese) |
- |
500 |
|
NA |
3.1 & Table 1 of IS 5522 (Nickel) |
- |
500 |
|
NA |
3.1 & Table 1 of IS 5522 (Chromium) |
- |
500 |
|
NA |
3.1 & Table 1 of IS 5522 (Sulphur) |
- |
500 |
|
NA |
3.1 & Table 1 of IS 5522 (Phosphorus) |
- |
500 |
|
NA |
3.1 & Table 1 of IS 5522 (Copper) |
- |
750 |
|
NA |
3.1 & Table 1 of IS 5522 (Nitrogen) |
- |
750 |
|
NA |
4.1(Shape and Dimension,) |
- |
400 |
|
NA |
4.2(Thickness) |
- |
100 |
|
NA |
5.1(Workmanship And Finish) |
- |
500 |
|
NA |
5.2(Workmanship And Finish) |
- |
500 |
|
NA |
5.3(Workmanship And Finish) |
- |
500 |
|
NA |
5.4(Workmanship And Finish) |
- |
500 |
|
NA |
6.1(Staining Test) |
- |
500 |
|
NA |
6.2(Mechanical Shock Test (for cladded utensils only)) |
- |
500 |
|
NA |
6.3(Thermal Shock Test (for cladded utensils only)) |
- |
500 |
|
NA |
6.4(Dry Heat Test (for cladded utensils only)) |
- |
1500 |
|
NA |
6.4(Dry Heat Test (for cladded utensils only)) |
- |
1500 |
|
NA |
3.1(Material) |
- |
5000 |
|
NA |
3.2(Material) |
- |
5000 |
|
NA |
3.3(Material) |
- |
5000 |
|
NA |
3.4(Material) |
- |
5000 |
|
NA |
3.5(Material) |
- |
5000 |
|
NA |
3.5(Material) |
- |
5000 |
|
NA |
3.5(Material) |
- |
5000 |
|
NA |
3.5(Material) |
- |
5000 |
|
NA |
4.1 (Annex A)(Shapes and Dimensions) |
- |
500 |
|
NA |
4.2 (Table 1)(Shapes and Dimensions) |
- |
500 |
|
NA |
4.2 (Table 1)(Shapes and Dimensions) |
- |
500 |
|
NA |
4.2(Shapes and Dimensions) |
- |
500 |
|
NA |
4.3(Shapes and Dimensions) |
- |
500 |
|
NA |
4.4(Shapes and Dimensions) |
- |
500 |
|
NA |
5.1(Workmanship and Finish) |
- |
500 |
|
NA |
5.1(Workmanship and Finish) |
- |
500 |
|
NA |
5.1(Workmanship and Finish) |
- |
500 |
|
NA |
5.2(Workmanship and Finish) |
- |
500 |
|
NA |
5.3(Workmanship and Finish) |
- |
500 |
|
NA |
5.3(Workmanship and Finish) |
- |
500 |
|
NA |
5.3(Workmanship and Finish) |
- |
500 |
|
NA |
5.3(Workmanship and Finish) |
- |
500 |
|
NA |
5.3(Workmanship and Finish) |
- |
500 |
|
NA |
5.3(Workmanship and Finish) |
- |
500 |
|
NA |
5.4(Workmanship and Finish) |
- |
500 |
|
NA |
5.5(Workmanship and Finish) |
- |
500 |
|
NA |
5.6(Workmanship and Finish) |
- |
500 |
|
NA |
6.1(Staining Test) |
- |
500 |
|
NA |
6.1(Staining Test) |
- |
500 |
|
NA |
6.2(Mechanical Shock Test (For Cladded Utensils only)) |
- |
500 |
|
NA |
6.3(Thermal Shock Test (For Cladded Utensils only)) |
- |
500 |
|
NA |
6.4(Dry Heat Test (For Cladded Utensils only)) |
- |
1500 |
|
NA |
6.5(Coating Thickness Test (For Copper Deposit)) |
- |
500 |
|
NA |
6.6(3 Ply) |
- |
1500 |
|
NA |
6.7.1(Nominal Capacity Test) |
- |
1000 |
|
NA |
6.7.2(Nominal Capacity Test- Diameter) |
- |
1000 |
|
NA |
6.8.1(Tests on Tempered Glass Lid) |
- |
500 |
|
NA |
6.8.1(Tests on Tempered Glass Lid) |
- |
500 |
|
NA |
6.8.2(Tests on Tempered Glass Lid (Ball drop test)) |
- |
500 |
|
NA |
6.8.3(Tests on Tempered Glass Lid (thermal shock test)) |
- |
500 |
|
NA |
6.8.4.1(Tests on Tempered Glass Lid (Free Fall Test with rim facing down)) |
- |
1000 |
|
NA |
6.8.4.2(Tests on Tempered Glass Lid (Free Fall Test without rim facing down)) |
- |
1000 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- Included w.e.f. 6-6-2022 |
37 |
IS 15997 (2012) |
Low nickel austenitic stainless steel sheet and strip for utensils and kitchen appliances - Specification |
- |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 8.1, 8.1.1 & 10.1 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
550 |
|
10% Discount to BIS |
Cl. 8.1, 8.1.1 & 10.1 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
550 |
|
10% Discount to BIS |
Cl. 8.1, 8.1.1 & 10.1 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
550 |
|
10% Discount to BIS |
Cl. 8.1, 8.1.1 & 10.1 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
550 |
|
10% Discount to BIS |
Cl. 8.1, 8.1.1 & 10.1 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
550 |
|
10% Discount to BIS |
Cl. 8.1, 8.1.1 & 10.1 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
550 |
|
10% Discount to BIS |
Cl. 8.1, 8.1.1 & 10.1 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
550 |
|
10% Discount to BIS |
Cl. 8.1, 8.1.1 & 10.1 Table 1(Copper -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
550 |
|
10% Discount to BIS |
Cl. 8.1, 8.1.1 & 10.1 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
550 |
|
10% Discount to BIS |
6(Freedom From Defects) |
- |
50 |
|
10% Discount to BIS |
9.3(Tensile Test-1608:Part 1) |
- |
750 |
|
10% Discount to BIS |
9.3, Table 3 (Yield Strength, Mpa) |
- |
750 |
|
10% Discount to BIS |
9.3, Table 3 (Tensile Strength, Mpa) |
- |
750 |
|
10% Discount to BIS |
9.3, Table 3 (Elongation, %) |
- |
750 |
|
10% Discount to BIS |
9.4(Erichsen Cupping Test,(Average depth of cupping) mm) |
- |
750 |
|
10% Discount to BIS |
11(Surface finish) |
- |
250 |
|
10% Discount to BIS |
12(Dimensions) |
- |
250 |
|
10% Discount to BIS |
14.1(Thickness,mm) |
- |
150 |
|
10% Discount to BIS |
14.2( Width, mm) |
- |
150 |
|
10% Discount to BIS |
14.3(Length, mm) |
- |
150 |
|
10% Discount to BIS |
14.4(Flatness, mm) |
- |
150 |
|
10% Discount to BIS |
14.5(Camber, mm) |
- |
150 |
|
10% Discount to BIS |
|
Complete
|
|
05 Oct, 2025 |
- Included w.e.f. 09-02-2021. |
38 |
IS 9573 : Part 2 (2017) |
Rubber hose for liquefied petroleum gas (Lpg) - Specification: Part 2 domestic and commercial application (Fourth Revision) |
- |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 4.1(General) |
- |
100 |
|
10% Discount to BIS |
Clause 4.2(Material) |
- |
100 |
|
10% Discount to BIS |
Clause 4.2.1(Lining) |
- |
100 |
|
10% Discount to BIS |
Clause 4.2.2 (a)(Reinforcement) |
- |
100 |
|
10% Discount to BIS |
Clause 4.2.2 (b)(Reinforcement) |
- |
100 |
|
10% Discount to BIS |
Clause 4.2.3(Cover) |
- |
100 |
|
10% Discount to BIS |
Clause 4.3
Sub Clause 4.3.1
Table 1(Bore Size) |
- |
290 |
|
10% Discount to BIS |
Clause 4.3
Sub Clause 4.3.2 (a)(Thickness of Lining and Cover) |
- |
400 |
|
10% Discount to BIS |
Clause 4.3
Sub Clause 4.3.2 (b)(Thickness of Lining and Cover) |
- |
200 |
|
10% Discount to BIS |
Clause 4.3
Sub Clause 4.3.3(Length) |
- |
500 |
|
10% Discount to BIS |
Clause 4.4
Sub Clause 4.4.1
Table 2 (i) (a)(Tensile Strength- Lining) |
- |
500 |
|
10% Discount to BIS |
Clause 4.4
Sub Clause 4.4.1
Table 2 (i) (b)(Tensile Strength- cover) |
- |
500 |
|
10% Discount to BIS |
Clause 4.4
Sub Clause 4.4.1
Table 2 (ii) (a)(Elongation at break- Lining) |
- |
500 |
|
10% Discount to BIS |
Clause 4.4
Sub Clause 4.4.1
Table 2 (ii) (b)(Elongation at break- Cover) |
- |
500 |
|
10% Discount to BIS |
Clause 4.4
Sub Clause 4.4.2
(a)(Accelerated Ageing Test lining) |
- |
500 |
|
10% Discount to BIS |
Clause 4.4
Sub Clause 4.4.2
(b)(Accelerated Ageing Test lining) |
- |
500 |
|
10% Discount to BIS |
Clause 4.4
Sub Clause 4.4.3
(a)(Resistance of Lining to n-pentane) |
- |
1200 |
|
10% Discount to BIS |
Clause 4.4
Sub Clause 4.4.3
(b)(Resistance of Lining to n-pentane) |
- |
1200 |
|
10% Discount to BIS |
Clause 4.5
Sub clause 4.5.1(Adhesion) |
- |
750 |
|
10% Discount to BIS |
Clause 4.5
Sub clause 4.5.2(Low Temperature Flexibility) |
- |
1500 |
|
10% Discount to BIS |
Clause 4.5
Sub clause 4.5.3(Flexibility of Hose) |
- |
300 |
|
10% Discount to BIS |
Clause 4.5
Sub clause 4.5.4(Ozone Resistance) |
- |
2500 |
|
10% Discount to BIS |
Clause 4.5
Sub clause 4.5.5
4.5.5.1(Proof pressure test) |
- |
700 |
|
10% Discount to BIS |
Clause 4.5
Sub clause 4.5.5
4.5.5.2(Bursting pressure) |
- |
700 |
|
10% Discount to BIS |
Clause 4.5
Sub clause 4.5.6(Grip Strength Test) |
- |
500 |
|
10% Discount to BIS |
Clause 4.5
Sub clause 4.5.7(Burning Behaviour) |
- |
500 |
|
10% Discount to BIS |
Clause 5.2
(a)(Marking
Manufacturer’s name or trade-mark, if any
) |
- |
20 |
|
10% Discount to BIS |
Clause 5.2
(b)(Marking
Words LPG, Max W.P. 1.0 MPa;
) |
- |
20 |
|
10% Discount to BIS |
Clause 5.2
(c)(Marking
Nominal bore, 1000111) |
- |
20 |
|
10% Discount to BIS |
Clause 5.2
(d)(Marking
Batch/Lot No.
) |
- |
20 |
|
10% Discount to BIS |
Clause 5.2
(e)(Marking
Month and year of manufacture
) |
- |
20 |
|
10% Discount to BIS |
Clause 5.2
(f)(Marking
IS 9573 (Part 2)
) |
- |
20 |
|
10% Discount to BIS |
Clause 5.2
(f)(Marking
ecommended to replace before (MONTH/YEAR)
) |
- |
20 |
|
10% Discount to BIS |
Clause 5.2.1(BIS Certification Marking
) |
- |
20 |
|
10% Discount to BIS |
|
Complete
|
|
05 Oct, 2025 |
- REVISED IS 9573-
2:2017 included w.e.f.
11.12.2018. |
39 |
IS 9573 : Part 1 (2017) |
Rubber hose for liquefied petroleum gas (Lpg) - Specification: Part 1 industrial application (Fourth Revision) |
All Size |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 5.2.1(BIS Certification Marking
) |
- |
10 |
|
NA |
Clause 5.2
(f)(Marking
IS 9573 (Part 1)
) |
- |
10 |
|
NA |
Clause 5.2
(e)(Marking
Month and year of manufacture
) |
- |
10 |
|
NA |
Clause 5.2
(d)(Marking
Batch/Lot No.
) |
- |
10 |
|
NA |
Clause 4.1 (General) |
- |
100 |
|
NA |
Clause 4.1(General) |
- |
100 |
|
NA |
Clause 4.2(Material) |
- |
100 |
|
NA |
Clause 4.2.1(Lining) |
- |
100 |
|
NA |
Clause 4.2.2(Reinforcement) |
- |
100 |
|
NA |
Clause 4.2.3(Cover) |
- |
100 |
|
NA |
Clause 4.3
Sub Clause 4.3.1
Table 1(Bore Size) |
- |
100 |
|
NA |
Clause 4.3
Sub Clause 4.3.2 (a)(Thickness of Lining and Cover) |
- |
100 |
|
NA |
Clause 4.3
Sub Clause 4.3.2 (b)(Thickness of Lining and Cover) |
- |
100 |
|
NA |
Clause 4.3
Sub Clause 4.3.3(Length) |
- |
100 |
|
NA |
Clause 4.4
Sub Clause 4.4.1
Table 2 (i) (a)(Tensile Strength- Lining) |
- |
1000 |
|
NA |
Clause 4.4
Sub Clause 4.4.1
Table 2 (i) (b)(Tensile Strength- cover) |
- |
1000 |
|
NA |
Clause 4.4
Sub Clause 4.4.1
Table 2 (ii) (a)(Elongation at break- Lining) |
- |
1000 |
|
NA |
Clause 4.4
Sub Clause 4.4.1
Table 2 (ii) (b)(Elongation at break- cover) |
- |
1000 |
|
NA |
Clause 4.4
Sub Clause 4.4.2
(a)(Accelerated Ageing Test lining) |
- |
600 |
|
NA |
Clause 4.4
Sub Clause 4.4.2
(b)(Accelerated Ageing Test lining) |
- |
400 |
|
NA |
Clause 4.4
Sub Clause 4.4.2
(a)(Accelerated Ageing Test cover) |
- |
400 |
|
NA |
Clause 4.4
Sub Clause 4.4.2
(b)(Accelerated Ageing Test cover) |
- |
400 |
|
NA |
Clause 4.4
Sub Clause 4.4.3
(a)(Resistance of Lining to n-pentane) |
- |
400 |
|
NA |
Clause 4.4
Sub Clause 4.4.3
(b)(Resistance of Lining to n-pentane) |
- |
400 |
|
NA |
Clause 4.5
Sub clause 4.5.1(Adhesion) |
- |
930 |
|
NA |
Clause 4.5
Sub clause 4.5.2(Low Temperature Flexibility) |
- |
2000 |
|
NA |
Clause 4.5
Sub clause 4.5.3(Flexibility of Hose) |
- |
800 |
|
NA |
Clause 4.5
Sub clause 4.5.4(Ozone Resistance) |
- |
1500 |
|
NA |
Clause 4.5
Sub clause 4.5.5
4.5.5.1(Proof pressure test) |
- |
600 |
|
NA |
Clause 4.5
Sub clause 4.5.5
4.5.5.2(Bursting pressure) |
- |
500 |
|
NA |
Clause 4.5
Sub clause 4.5.6(Electrical Continuity Test) |
- |
500 |
|
NA |
Clause 4.5
Sub clause 4.5.7(Burning Behaviour) |
- |
500 |
|
NA |
Clause 5.2
(a)(Marking
Manufacturer’s name or trade-mark, if any
) |
- |
10 |
|
NA |
Clause 5.2
(b)(Marking
Words LPG, Max W.P. 2.5 MPa;
) |
- |
10 |
|
NA |
Clause 5.2
(c)(Marking
Nominal bore
) |
- |
10 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- REVISED IS 9573-
1:2017 included w.e.f.
11.12.2018. |
40 |
IS 733 (1983) |
Specification for wrought aluminium and aluminium alloy bars, rods and sections (For General Engineering Purposes) (Third Revision) |
- |
-
|
6000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 4(Freedom from Defects) |
- |
150 |
|
NA |
Cl. 5.1, Table 2(0.2 Percent proof stress- IS 1816) |
- |
150 |
|
NA |
Cl. 5.1, Table 2(Tensile Strength- IS 1816) |
- |
1000 |
|
NA |
Cl. 5.1, Table 2(Elongation on 50 mm or 5.65√So Gauge Length) |
- |
500 |
|
NA |
Cl. 0.4, 5.1, Table 1(Aluminium- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
NA |
Cl. 0.4, 5.1, Table 1(Copper- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
NA |
Cl. 0.4, 5.1, Table 1(Magnesium- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
NA |
Cl. 0.4, 5.1, Table 1(Silicon- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
NA |
Cl. 0.4, 5.1, Table 1(Iron- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
NA |
Cl. 0.4, 5.1, Table 1(Zinc- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
NA |
Cl. 0.4, 5.1, Table 1(Titanium and / or other grain refining elements - IS 504 or by any other suitable instrumental method) |
- |
200 |
|
NA |
Cl. 0.4, 5.1, Table 1(Chromium- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
NA |
Cl. 0.4, 5.1, Table 1(Ti+ V- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
NA |
Cl. 0.4, 5.1, Table 1(Total Impurities- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
NA |
Cl. 0.4, 5.1, Table 1(Cr+ Mn- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- Included w.e.f. 09-02-2021. |
41 |
IS 366 (1991) |
Electric iron - Specification (Fourth Revision) |
- |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.0(Classification (as per Cl.6 of IS 302-2-3 and Cl.6.1 of IS 302-1)) |
- |
50 |
|
NA |
7.0(Classification (as per Cl.6 of IS 302-2-3 and Cl.6.2 of IS 302-1)) |
- |
50 |
|
NA |
9.0(Protection against access to live parts (as per Cl. 8 of IS 302-2-3 and IS 302-1)) |
- |
100 |
|
NA |
9.0(Power input and current (as per Cl. 10 of IS 302-2-3 and IS 302-1)) |
- |
100 |
|
NA |
9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
300 |
|
NA |
9.0(Leakage current and Electric Strength at Operating Temperature (as per Cl. 13 of IS 302-2-3 and IS 302-1)) |
- |
200 |
|
NA |
9.0(Transient Overvoltage (as per of Cl. 14 of IS 302-2-3 and Table 6 of IS 302-1)) |
- |
200 |
|
NA |
9.0(Moisture Resistance (as per of Cl.15 of IS 302-2-3 and IS 302-1)) |
- |
300 |
|
NA |
9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
200 |
|
NA |
9.0(Staibilty and mechanical hazards (as per of Cl.20 of IS 302-2-3 and IS 302-1) ) |
- |
300 |
|
NA |
9.0(Mechanical strength (as per of Cl.21 of IS 302-2-3 and IS 302-1) ) |
- |
300 |
|
NA |
9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
400 |
|
NA |
9.0(Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
300 |
|
NA |
6(Measurement of Thermostatic staibility) |
- |
500 |
|
NA |
9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
NA |
9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
NA |
9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
NA |
9.0(Leakage current and Electric Strength at Operating Temperature (as per Cl. 13 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
NA |
9.0(Moisture Resistance (as per of Cl.15 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
NA |
16 of IS 302-2-3(Leakage current electric strength) |
- |
500 |
|
NA |
9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
NA |
9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
NA |
9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
NA |
9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
NA |
9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
NA |
9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
NA |
9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
NA |
9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
NA |
9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
NA |
9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
NA |
9.0(Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
NA |
9.0(Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
NA |
9.0(Components (as per of Cl.24 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
NA |
9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
NA |
9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
NA |
9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
NA |
9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
NA |
9.0(Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
NA |
9.0(Terminals for external conductors (as per of Cl.26 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
NA |
9.0(Screw and connections (as per of Cl.28 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
NA |
9.0(Clearances, creepage distances and solid insulation (as per of Cl.29 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
NA |
9.0(Resistance to Heat and Fire (as per of Cl.30 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
NA |
9.0(Resistance to Rusting (as per of Cl.31 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
NA |
10.0(Measurement of Heating up time) |
- |
500 |
|
NA |
10.0(Measurement of Heating up time) |
- |
500 |
|
NA |
11.0(Measurement of sole plate temperature) |
- |
500 |
|
NA |
11.0(Measurement of sole plate temperature) |
- |
500 |
|
NA |
12.0(Measurement of Tempearture Distribution) |
- |
500 |
|
NA |
13.0(Measurement of Initial overswing temperature and Heating up excess temperature) |
- |
500 |
|
NA |
13.0(Measurement of Initial overswing temperature and Heating up excess temperature) |
- |
500 |
|
NA |
14.0(Measurement of Cyclic fluctuation of temperature of hottest point ) |
- |
500 |
|
NA |
15(MEASUREMENT OF TEMPERATURE DROP UNDER LOAD) |
- |
500 |
|
NA |
16.0(Measurement of Thermostatic staibility) |
- |
500 |
|
NA |
16.0(Measurement of Thermostatic staibility) |
- |
500 |
|
NA |
17(Measurement of Thermostatic staibility) |
- |
500 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- Included w.e.f. 09-02-2021. |
42 |
IS 8978 (1992) |
Specification for electric instantaneous water heaters (Second Revision) |
- |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.7 of IS 302-2-35:2017(Marking) |
- |
1000 |
|
NA |
Cl.6 of IS 302-2-35:2017(Classification) |
- |
1000 |
|
NA |
Cl.8 of IS 302-2-35:2017(Protection Against Access To Live Parts) |
- |
1000 |
|
NA |
Cl.10 of IS 302-2- 35:2011(Power Input & Current ) |
- |
1000 |
|
NA |
Cl.11 of 302-2-35:2017(Heating) |
- |
1000 |
|
NA |
Cl.13 of IS 302-2-35:2017(Leakage Current & Electrical Strength at Operating Temperature ) |
- |
1000 |
|
NA |
Cl.14 of IS 302-2-35:2017(Transient Over Voltages ) |
- |
1000 |
|
NA |
Cl.15 of IS 302-2-35-2011(Moisture Resistance ) |
- |
1000 |
|
NA |
Cl.16 of IS 302-2-35:2011(Leakage Current and Electric Strength) |
- |
200 |
|
NA |
Cl.17 IS 302-2-35:2017(Overload Protection of Transformers & Associated circuits ) |
- |
200 |
|
NA |
Cl.19 of IS 302-2-35:2017(Abnormal Operation) |
- |
200 |
|
NA |
Cl.20 of IS 302-2-35-2011(Stability & Mechanical Hazards
) |
- |
500 |
|
NA |
Cl.21.1 of IS 302-2-35-2011(Mechanical strength) |
- |
200 |
|
NA |
Cl.22 of IS 302-2-35-2011(Construction
) |
- |
500 |
|
NA |
Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
400 |
|
NA |
Cl.24 of IS 302-2-35:2017(Component
) |
- |
500 |
|
NA |
Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
500 |
|
NA |
Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
500 |
|
NA |
Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
500 |
|
NA |
Cl.28 of IS 302-2-35:2017(Screws and Connections
) |
- |
500 |
|
NA |
Cl.29 of IS 302-2-35:2017(Clearances, Creepage Distances and Solid Insulation) |
- |
500 |
|
NA |
Cl.7 of IS 302-2-35:2017(Marking) |
- |
200 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- Included w.e.f. 09-02-2021. |
43 |
IS 6603 (2001) |
Stainless steel bars and flats - Specification (First Revision) |
- |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Carbon -Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
500 |
|
NA |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Silicon- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
550 |
|
NA |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Manganese- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
550 |
|
NA |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Nickel -Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
550 |
|
NA |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Chromium- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
550 |
|
NA |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Molybdenum- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
550 |
|
NA |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Titanium- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
550 |
|
NA |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Niobium- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
550 |
|
NA |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Sulphur- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
550 |
|
NA |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Phosphorus- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
550 |
|
NA |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Others (Nitrogen)- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
550 |
|
NA |
Cl.14.1(Corrosion Resistance- IS 10461(Part1)) |
- |
1400 |
|
NA |
6(Freedom from defects:) |
- |
200 |
|
NA |
9.1, Table 3(0.2 Percent Proof Stress, MPa) |
- |
400 |
|
NA |
9.2, Table 3(Tensile Strength, MPa) |
- |
700 |
|
NA |
9.3, Table 3(Elongation ,Percent) |
- |
300 |
|
NA |
9.4, Table 3(Annealed Hardness, HB-IS 1500: Pt 1) |
- |
400 |
|
NA |
9.5, Table 3(Charpy Impact Test, J-IS 1499) |
- |
300 |
|
NA |
12(Dimensions & Tolerances, mm-IS 6603) |
- |
100 |
|
NA |
12(Diameter, mm) |
- |
50 |
|
NA |
12(Out of Round , mm) |
- |
50 |
|
NA |
12(Length , mm) |
- |
50 |
|
NA |
12(Variation in Straightness) |
- |
50 |
|
NA |
Cl.14.1(Corrosion Resistance- IS 10461(Part2)) |
- |
1000 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- Included w.e.f. 09-02-2021. |
44 |
IS 4159 (2002) |
Mineral filled sheathed heating elements - Specification (Third Revision) |
- |
-
|
9500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6 of IS 4159:2002 &
IS 302-1:2008
(Classification) |
- |
0 |
|
NA |
Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
0 |
|
NA |
Cl.8 of IS 4159:2002 & IS 302‐1:2008(Protection Against Electric Shock) |
- |
300 |
|
NA |
Cl.10 of IS 4159:2002 &
IS 302-1:2008(Input & Current) |
- |
700 |
|
NA |
Cl.11 of IS 4159:2002 & IS 302‐1:2008(Temperature Rise) |
- |
1000 |
|
NA |
Cl.13 of IS 4159:2002 & IS 302-1: 2008(Electrical Insulation and Leakage Current at Operating Temperature) |
- |
250 |
|
NA |
Cl.15 of IS 4159:2002 & IS 302-1: 2008(Moisture Resistance) |
- |
1000 |
|
NA |
Cl.16 of IS 4159:2002 & IS 302-1: 2008(Insulation Resistance & Electric Strength (after Humidity Treatment)) |
- |
250 |
|
NA |
Cl.18 of IS 4159:2002(Endurance Test
) |
- |
0 |
|
NA |
Cl.19 of IS 4159:2002 & IS 302-1: 2008(Abnormal Operation) |
- |
200 |
|
NA |
Cl.20 of IS 4159:2002 & IS 302-1: 2008(Stability & Mechanical Hazards
) |
- |
300 |
|
NA |
Cl.21 of IS 4159:2002 & IS 302-1: 2008(Mechanical Strength) |
- |
500 |
|
NA |
Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
100 |
|
NA |
Cl.23 of IS 4159:2002 &
IS 302-1: 2008(Internal Wiring
) |
- |
0 |
|
NA |
Cl.24 of IS 4159:2002 &
IS 302-1: 2008(Component ) |
- |
100 |
|
NA |
Cl.25 of IS 4159:2002 & IS 302-1: 2008(Supply connection & external flexible cables & cords) |
- |
100 |
|
NA |
Cl.26 of IS 4159:2002 & IS 302-1: 2008(Terminals for External Conductors) |
- |
0 |
|
NA |
Cl.27 of IS 4159:2002 & IS 302-1: 2008(Provision for Earthing) |
- |
400 |
|
NA |
Cl. 29 of IS 4159:2002 &
IS 302-1: 2008(Creepage Distances & Clearances) |
- |
400 |
|
NA |
Cl. 30 of IS 4159:2002 &
IS 302-1: 2008(Resistance to Heat, Fire and Tracking) |
- |
1500 |
|
NA |
Cl. 31 of IS 4159:2002 &
IS 302-1: 2008(Resistance to Rusting) |
- |
1500 |
|
NA |
Cl. 33.1 of IS 4159:2002(Finish Test
) |
- |
0 |
|
NA |
Cl. 102 of IS 4159:2002(Leakage & Hydrostatic Strength Test
(for Oil heating elements)
) |
- |
0 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- Included w.e.f. 09-02-2021. |
45 |
IS 302 : Part 2 : Sec 30 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 30 room heaters (First Revision) |
- |
-
|
9000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6 (Classification) |
- |
100 |
|
NA |
Cl.8 & IS:302-1:2008(Protection Against Access to Live Parts) |
- |
100 |
|
NA |
Cl.10 & IS:302-1:2008(Power Input and Current) |
- |
300 |
|
NA |
Cl.11 & IS:302-1:2008(Heating) |
- |
1000 |
|
NA |
Cl.13 & IS:302-1:2008(Leakage Current & Electric Strength at operating temp. ) |
- |
500 |
|
NA |
Cl.14 & IS:302-1:2008(Transient Over Voltages) |
- |
500 |
|
NA |
Cl.15 & IS: 302-1:2008(Moisture Resistance
) |
- |
500 |
|
NA |
Cl.17 & IS:302-1:2008(Over load Protection of Transformers and Associated Circuits ) |
- |
500 |
|
NA |
Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
400 |
|
NA |
Cl.20 & IS:302-1:2008(Stability & Mechanical Hazards) |
- |
300 |
|
NA |
Cl.21 & IS:302-1:2008)(Mechanical Strength.) |
- |
300 |
|
NA |
Cl.22.1 of IS 302-1:2008(Construction) |
- |
500 |
|
NA |
Cl.24.1.3 (Component) |
- |
300 |
|
NA |
Cl.25.1 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
700 |
|
NA |
Cl.27.1 of 302-1:2008(Provision for Earthing.) |
- |
700 |
|
NA |
Cl.28 of 302-1:2008(Screws and Connections.) |
- |
100 |
|
NA |
Cl.29.1 of IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation : Clearance ) |
- |
200 |
|
NA |
Cl.30.2.2 of 302-1:2008(Resistance to Heat and Fire) |
- |
1000 |
|
NA |
Cl.31 & IS:302-1:2008(Resistance to Rusting.) |
- |
1000 |
|
NA |
Cl.6 (Classification) |
- |
100 |
|
NA |
Cl.7(Marking and Instructions) |
- |
100 |
|
NA |
Cl.7(Marking and Instructions) |
- |
100 |
|
NA |
Cl.7(Marking and Instructions) |
- |
100 |
|
NA |
Cl.7.3(Marking and Instructions) |
- |
100 |
|
NA |
Cl.7.4(Marking and Instructions) |
- |
100 |
|
NA |
Cl.7.5(Marking and Instructions) |
- |
100 |
|
NA |
Cl.7.6 & IS:302-1:2008(Marking and Instructions) |
- |
100 |
|
NA |
Cl.7.8 of IS :302-1:2008(Marking and Instructions) |
- |
100 |
|
NA |
Cl.7.9 of IS :302-1:2008(Marking and Instructions) |
- |
100 |
|
NA |
Cl.7.10 of IS :302-1:2008(Marking and Instructions) |
- |
100 |
|
NA |
Cl.7.11 of IS :302-1:2008(Marking and Instructions) |
- |
100 |
|
NA |
Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
100 |
|
NA |
Cl.7.13 of IS 302-1:2008(Marking and Instructions) |
- |
100 |
|
NA |
Cl.7.14 of IS302-1:2008(Marking and Instructions) |
- |
100 |
|
NA |
Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
100 |
|
NA |
Cl.7.101(Marking and Instructions) |
- |
100 |
|
NA |
Cl.16 & IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
100 |
|
NA |
Cl.16 & IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
100 |
|
NA |
Cl.23 & IS:302-1:2008(Internal Wiring
) |
- |
100 |
|
NA |
Cl.26.11 of IS 302-1:2008(Terminal for External Conductors
) |
- |
1000 |
|
NA |
Cl.26 of IS 302-1:2008(Terminal for External Conductors
) |
- |
1000 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- Included w.e.f. 09-02-2021. |
46 |
IS 319 (2007) |
Free cutting brass bars, rods and section - Specification (Fifth Revision) |
- |
-
|
6000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.0(Freedom from defects) |
- |
100 |
|
NA |
7.0(Dimension and Tolerances) |
- |
200 |
|
NA |
8.1 Table 1(Cu) |
- |
700 |
|
NA |
8.1 Table 1(Pb) |
- |
700 |
|
NA |
8.1 Table 1(Fe) |
- |
700 |
|
NA |
8.1 Table 1(Total other impurities excluding iron) |
- |
500 |
|
NA |
8.1 Table 1(Zn) |
- |
700 |
|
NA |
9.1 Table-2(Tensile Strength) |
- |
700 |
|
NA |
9.1 Table-2(Elongation) |
- |
700 |
|
NA |
9.2(Vickers Hardness) |
- |
500 |
|
NA |
10.1(Mercurous Nitrate Test) |
- |
500 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- Included w.e.f. 09-02-2021. |
47 |
IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
- |
-
|
16256 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8(Protection against live parts) |
- |
500 |
|
NA |
10(POWER INPUT AND CURRENT) |
- |
700 |
|
NA |
11(HEATING) |
- |
1500 |
|
NA |
13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1200 |
|
NA |
14(TRANSIENT OVERVOLTAGES) |
- |
1000 |
|
NA |
15(MOISTURE RESISTANCE) |
- |
1500 |
|
NA |
16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1300 |
|
NA |
17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1500 |
|
NA |
19(ABNORMAL OPERATION) |
- |
2000 |
|
NA |
18(ENDURANCE) |
- |
1000 |
|
NA |
20(STABILITY AND MECHANICAL HAZARDS) |
- |
1000 |
|
NA |
21(MECHANICAL STRENGTH) |
- |
1000 |
|
NA |
22(CONSTRUCTION) |
- |
1000 |
|
NA |
23(INTERNAL WIRING) |
- |
1000 |
|
NA |
24(COMPONENTS) |
- |
1000 |
|
NA |
25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
1000 |
|
NA |
26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
NA |
27(PROVISION FOR EARTHING) |
- |
1000 |
|
NA |
28(SCREWS AND CONNECTIONS) |
- |
100 |
|
NA |
29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
100 |
|
NA |
30(RESISTANCE TO HEAT AND FIRE) |
- |
100 |
|
NA |
31(RESISTANCE TO RUSTING) |
- |
100 |
|
NA |
32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
100 |
|
NA |
6.0(Classification) |
- |
100 |
|
NA |
7(Marking and instructions) |
- |
100 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- Included w.e.f. 09-02-2021. |
48 |
IS 368 (2014) |
Electric immersion water heaters - Specification (Fifth Revision) |
- |
-
|
12000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6 of IS 302-‐2-‐201:2008(Classification) |
- |
50 |
|
NA |
Cl.8 of IS 302‐2-201: 2008(Protection Against Access to Live Parts) |
- |
100 |
|
NA |
Cl.10 of IS 302‐2‐201:2008(Power Input and Current ) |
- |
300 |
|
NA |
Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
NA |
Cl. 12 of IS 368:2014(Operation under overload conditions of appliances with heating elements) |
- |
500 |
|
NA |
Cl.13 of IS 302-2-201: 2008(Leakage Current & Electric Strength at Operating Temperature) |
- |
300 |
|
NA |
Cl.14 of IS 302‐2-201:2008(Transient Over Voltages ) |
- |
300 |
|
NA |
Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
700 |
|
NA |
Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
700 |
|
NA |
Cl.17 of IS 302‐2-201: 2008(Overload Protection of Transformers & Associated Circuits) |
- |
500 |
|
NA |
Cl.18 of IS 368:2014(Endurance) |
- |
500 |
|
NA |
Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
300 |
|
NA |
Cl.20 of IS 302-2-201: 2008(Stability & Mechanical Hazards) |
- |
300 |
|
NA |
Cl.22 of IS 302-2-201: 2008(Construction) |
- |
300 |
|
NA |
Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
300 |
|
NA |
Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
300 |
|
NA |
Cl.24 of IS 302-2-201: 2008(Component) |
- |
300 |
|
NA |
Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
500 |
|
NA |
Cl.26 of IS 302-2-201: 2008(Terminals for External Conductors) |
- |
500 |
|
NA |
Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
700 |
|
NA |
Cl.29 of IS 302-2‐201:2008(Clearances, Creepage Distances and Solid Insulation ) |
- |
700 |
|
NA |
Cl.30 of IS 302-2‐201:2008(Resistance to Heat and Fire ) |
- |
1000 |
|
NA |
Cl.31 of IS 302-2-201:2008(Resistance of Rusting ) |
- |
1000 |
|
NA |
Cl.32 of IS 302-2-201:2008(Radiation, Toxicity and Similar Hazards) |
- |
500 |
|
NA |
Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
50 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- Included w.e.f. 09-02-2021. |
49 |
IS 2347 (2017) |
Domestic pressure cooker - Specification (Sixth Revision) |
- |
-
|
35000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1(Air Pressure Test) |
- |
2000 |
|
NA |
8.2(Proof Pressure Test) |
- |
1000 |
|
NA |
8.3(Operating Test for Pressure Regulating Device) |
- |
1000 |
|
NA |
8.4(Test for Safety Pressure Relief Device) |
- |
1400 |
|
NA |
8.5(Bursting Pressure Test) |
- |
1000 |
|
NA |
8.6.1(Tests for Removal of Lid under Pressure For Outer Lid Cooker) |
- |
500 |
|
NA |
8.6.2(Tests for Removal of Lid under Pressure For inner Lid Cooker) |
- |
500 |
|
NA |
8.7(Test for Spring Loaded Mechanism) |
- |
500 |
|
NA |
7.4(WORKMANSHIP AND FINISH) |
- |
500 |
|
NA |
7.1(WORKMANSHIP AND FINISH) |
- |
600 |
|
NA |
7.2(WORKMANSHIP AND FINISH) |
- |
500 |
|
NA |
7.3(WORKMANSHIP AND FINISH) |
- |
500 |
|
NA |
6.4.1(Handles and Knobs) |
- |
500 |
|
NA |
6.4.1.1(Handles and Knobs) |
- |
500 |
|
NA |
6.3.1(Temperature Responsive Pressure Relief Device) |
- |
500 |
|
NA |
6.3.1(Temperature Responsive Pressure Relief Device) |
- |
500 |
|
NA |
6.2(Safety Relief Device) |
- |
500 |
|
NA |
6.2.1(Safety Relief Device) |
- |
500 |
|
NA |
6.2.2(Safety Relief Device) |
- |
500 |
|
NA |
6.1(Pressure Regulating Device) |
- |
500 |
|
NA |
6.1.1(Pressure Regulating Device) |
- |
500 |
|
NA |
6.1.2(Pressure Regulating Device) |
- |
500 |
|
NA |
6.1.3(Pressure Regulating Device) |
- |
500 |
|
NA |
6.1.4(Pressure Regulating Device) |
- |
500 |
|
NA |
6.1.5(Pressure Regulating Device) |
- |
500 |
|
NA |
6(CONSTRUCTION) |
- |
500 |
|
NA |
5.9(Spring) |
- |
500 |
|
NA |
5.8(Vent Pipe Nut) |
- |
500 |
|
NA |
5.7(Vent Pipe) |
- |
500 |
|
NA |
5.6(Vent Seal Pin for Pressure Regulating Device) |
- |
500 |
|
NA |
5.5(Pressure Regulating Device) |
- |
500 |
|
NA |
5.4(Handles and Knobs) |
- |
500 |
|
NA |
5.3(Gasket) |
- |
2500 |
|
NA |
5.2(Safety Relief Device) |
- |
2000 |
|
NA |
5.1.1(Body, Lid, Containers and Grid) |
- |
500 |
|
NA |
5.1.2(Body, Lid, Containers and Grid) |
- |
500 |
|
NA |
5.1.3(Body, Lid, Containers and Grid) |
- |
500 |
|
NA |
5.1.4(Body, Lid, Containers and Grid) |
- |
500 |
|
NA |
4.1(Capacity) |
- |
500 |
|
NA |
8.8(Test for Spring Loaded Mechanism) |
- |
15000 |
|
- |
8.9(Test for Spring Loaded Mechanism) |
- |
10000 |
|
- |
8.1(testing of handles of the cooker) |
- |
5000 |
|
- |
|
Complete
|
|
05 Oct, 2025 |
- REVISED IS 2347:2017
included w.e.f.
11.12.2018 |
50 |
IS 2082 (2018) |
Stationary storage type electric water heaters - Specification (Fifth Revision) |
- |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
(Cl.8 of IS 302-2-21:2011)(Protection Against Access to Live Parts) |
- |
4000 |
|
NA |
(Cl.10 of IS 302-2-21: 2011)(Power Input & Current) |
- |
100 |
|
NA |
(Cl.11 of 302-2-21:2011)(Heating) |
- |
500 |
|
NA |
(Cl.13 of IS 302-2-21:2011)(Leakage Current ) |
- |
500 |
|
NA |
(Cl.13 of IS 302-2-21:2011)(Electrical Strength at Operating Temperature) |
- |
500 |
|
NA |
(Cl.14ofIS302-2-21:2011)(Transient Over Voltages) |
- |
500 |
|
NA |
(Cl.15 of IS 302-2-21-2011)(Moisture Resistance) |
- |
1500 |
|
NA |
(Cl.17 of IS 302-2-21:2011)(Overload protection of transformers & associated circuits) |
- |
1500 |
|
NA |
(Cl.19 of IS 302-2-21:2011)(Abnormal Operation) |
- |
500 |
|
NA |
(Cl.20 of IS 302-2-21:2011)(Stability & Mechanical Hazards) |
- |
700 |
|
NA |
(Cl.21ofIS302-2-21:2011)(Mechanical strength) |
- |
500 |
|
NA |
(Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
400 |
|
NA |
(Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
300 |
|
NA |
(Cl.24ofIS302-221:2011)(Component) |
- |
500 |
|
NA |
(Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
500 |
|
NA |
(Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
400 |
|
NA |
(Cl.27 of IS 302-2-21:2011)(Provision for Earthing) |
- |
250 |
|
NA |
(Cl.29ofIS302-2-21:2011)(Clearances, Creepage Distances and Solid Insulation) |
- |
1200 |
|
NA |
Cl.8 of IS 302-2-21:2018(Protection Against Access to Live Parts) |
- |
300 |
|
NA |
Cl.10 of IS 302-2-21: 2018(Power Input & Current) |
- |
300 |
|
NA |
Cl.11 of 302-2-21:2018(Heating : Room Temp.) |
- |
200 |
|
NA |
Cl.13 of IS 302-2-21:2018(Leakage Current ) |
- |
300 |
|
NA |
Cl.15 of IS 2082:2018(Verification of the Rated Capacity) |
- |
500 |
|
NA |
(Cl.17 of IS 2082:2018)(Hot Water Output) |
- |
200 |
|
NA |
Cl.19 of IS 302-2-21:2018(Abnormal Operation : leakage from container during test) |
- |
300 |
|
NA |
Cl.21.1 of IS 302-1:2008(Mechanical strength : Rough handling in normal use) |
- |
500 |
|
NA |
(Cl.22 of IS 2082:2018)(Finish) |
- |
200 |
|
NA |
Cl. 23 of IS 302-1:2008(Internal Wiring : color identification for earthing conductor
) |
- |
500 |
|
NA |
Cl.24.102 of IS 302-221:2018(Component : Operation of thermal cut-out ) |
- |
500 |
|
NA |
Cl.25.18 of IS 302-1:2008(Supply Connection & External Flexible Cords) |
- |
400 |
|
NA |
Cl.26 of IS 302-2-21: 2018(Terminals for External Conductors) |
- |
300 |
|
NA |
Cl.27 of IS 302-2-21:2018(Provision for Earthing) |
- |
200 |
|
NA |
Cl.29.1 of IS 302-1:2008(Clearances, Creepage Distances and Solid Insulation : Clearance distance ) |
- |
100 |
|
NA |
Cl.30.2 of IS 302-1:2008(Resistance to Heat & Fire : Glow wire test ) |
- |
500 |
|
NA |
Cl.16 of IS 302-2-21-2018(Leakage current and Electric strength (After humidity): Leakage current ) |
- |
200 |
|
NA |
Cl.16 of IS 302-2-21-2018(Leakage current and Electric strength (After humidity): Electric Strentgh ) |
- |
200 |
|
NA |
Cl.28 of IS 302-2-21:2018(Screws & Connections) |
- |
500 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- Included w.e.f. 09-02-2021. |
51 |
IS 15558 (2005) |
Mini domestic water heater for use with LPG - Specification |
- |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1(Materials) |
- |
200 |
|
NA |
5.2(Materials) |
- |
100 |
|
NA |
5.3(Materials) |
- |
100 |
|
NA |
5.4(Materials) |
- |
100 |
|
NA |
5.5(Materials) |
- |
100 |
|
NA |
6.1(Connections) |
- |
100 |
|
NA |
6.2(Connections) |
- |
100 |
|
NA |
6.3(Connections) |
- |
100 |
|
NA |
6.4(Connections) |
- |
100 |
|
NA |
6.5(Connections) |
- |
100 |
|
NA |
6.6(Gas Inlet Connections) |
- |
100 |
|
NA |
6.6(Gas Inlet Connections) |
- |
100 |
|
NA |
6.6(Gas Inlet Connections) |
- |
100 |
|
NA |
6.6(Gas Inlet Connections) |
- |
100 |
|
NA |
6.6(Gas Inlet Connections) |
- |
100 |
|
NA |
7(Flame Visibility) |
- |
100 |
|
NA |
8(Gas Taps) |
- |
200 |
|
NA |
9(Flame Failure Device) |
- |
200 |
|
NA |
10(Ignition Device) |
- |
100 |
|
NA |
11(Protection Against Accidental Overheating) |
- |
500 |
|
NA |
12(Water Rate Adjuster) |
- |
500 |
|
NA |
14(Gas Soundness) |
- |
200 |
|
NA |
15(Water Soundness) |
- |
300 |
|
NA |
16(Thermal Efficiency) |
- |
1500 |
|
NA |
17(Combustion) |
- |
500 |
|
NA |
18(Gas Consumption) |
- |
2000 |
|
NA |
19.1(Ignition and flame travel) |
- |
200 |
|
NA |
19.2(Ignition and flame travel) |
- |
100 |
|
NA |
19.3(Ignition and flame travel) |
- |
100 |
|
NA |
20(Flame Stability) |
- |
200 |
|
NA |
21(Noise Control) |
- |
200 |
|
NA |
22(Flash Back) |
- |
300 |
|
NA |
23(Resistance to Draught) |
- |
300 |
|
NA |
24(Fire Hazard And Limiting Temperature ) |
- |
400 |
|
NA |
25(Time For Temperature Rise) |
- |
500 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- - |
52 |
IS 1660 (2009) |
Wrought aluminium utensils - Specification (First Revision) |
- |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(Classification Heavy/Medium/L:ight) |
- |
100 |
|
NA |
4(Material) |
- |
100 |
|
NA |
0.5(Fabrication) |
- |
100 |
|
NA |
5.1(The utensil shall be pressed or spun from one piece) |
- |
100 |
|
NA |
5.2( Body Thickness of the thinnest part of the finished utensil, mm Not declared ) |
- |
100 |
|
NA |
5.2(Lid Thickness of the finished utensil, mm) |
- |
100 |
|
NA |
6.1 & Table 1( i) Name of Utensil ) |
- |
100 |
|
NA |
6.1 & Table 1(ii) Shape of Utensil) |
- |
100 |
|
NA |
6.1 & Table 1( Nominal Size, mm) |
- |
100 |
|
NA |
6.1 & Table 1(Inside dia, Φ D mm Not declared ) |
- |
200 |
|
NA |
6.1 & Table 1(Outside dia Ф NA) |
- |
200 |
|
NA |
6.1 & Table 1(Height NA) |
- |
200 |
|
NA |
6.1 & Table 1(Capacity, l NA) |
- |
200 |
|
NA |
6.1( Minimum sheet thickness for nominal size ) |
- |
200 |
|
NA |
7.1(HANDLES ,When fitted shall be of aluminium, stainless steel or of other suitable fire resistance material These shall be fastened to the utensils by tightly drawn aluminium or stainless steel rivets, by welding, by screwing to cast bosses or by riveting between flange at the end of the handles. Handles shall be so shaped and positioned to facilitate the carrying and handling of the utensils in normal use ) |
- |
500 |
|
NA |
7.2(Handles shall be sufficiently strong to support a mass in the utensils equivalent to three times the mass of the water capacity of the utensils in the position of normal use without visible permanent deformation of the handle or utensil) |
- |
500 |
|
NA |
8.1(The utensils shall be clean reasonably free from distortion, dents, wrinkles, wavy surface, burrs, scratches, pitting and deep tool marks and other surface defects) |
- |
500 |
|
NA |
8.2(The design of the utensils shall be such that it is easy to clean and prevent accumulation of dirt) |
- |
500 |
|
NA |
8.4.1.2( Finish of the coating: The coating shall be smooth continuous and uniform in appearance, and shall be adherent. It shall be free from powdery areas, loose films and discontinuities, such as breaks and scratches. The size and number of contact marks shall be minimum consistent with good practice.) |
- |
500 |
|
NA |
8.4.2(A coating of thickness 25 to 100 microns is generally required) |
- |
500 |
|
NA |
8.4.3(Abrasion Resistance When the coating surface is rubbed two or three times with emery paper with emery conforming to grit number 180 using medium finger pressure, it shall not abrade the surface but shall skid over the surface showing not more than a trace of whitening of the surface) |
- |
1500 |
|
NA |
8.4.4(The colour of the hard anodic coating varies depending upon the alloy, thickness of the coating and electrolye. Normally the colour may vary from dark grey (almost black) to light grey. ) |
- |
500 |
|
NA |
8.4.4(The film will appear dark grey when wet. ) |
- |
500 |
|
NA |
8.4.5 (When the coated surface is rubbed two or three times with fine emery paper grit number 180 using medium finger pressure, cloth or paper shall not abrade the surface. A faint trace of whitening on the cloth or paper is permissible) |
- |
500 |
|
NA |
9(The manufacturer shall provide full instructions for use and cleaning for coated or hard anodized utensils) |
- |
500 |
|
NA |
10(Each vessel shall be legibly and indelibly stamped on the outside surface or handle with the manufacturer’s name or registered trade-mark, size and thickness or class. ) |
- |
500 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- - |
53 |
IS 5522 (2014) |
Stainless steel sheets and strips for utensils - Specification (Third Revision) |
- |
-
|
6500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 7.1 & 7.2 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
399.97 |
|
NA |
Cl. 7.1 & 7.2 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
400 |
|
NA |
Cl. 7.1 & 7.2 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
400 |
|
NA |
Cl. 7.1 & 7.2 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
400 |
|
NA |
Cl. 7.1 & 7.2 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
400 |
|
NA |
Cl. 7.1 & 7.2 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
400 |
|
NA |
Cl. 7.1 & 7.2 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
400 |
|
NA |
Cl. 7.1 & 7.2 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
NA |
8.2, Table 3(Tensile Test-1608:Part 1) |
- |
500 |
|
NA |
8.2, Table 3(Proof Stress, N/mm2) |
- |
400 |
|
NA |
8.2, Table 3(Tensile Strength, N/mm2) |
- |
500 |
|
NA |
8.2, Table 3(Elongation, %) |
- |
500 |
|
NA |
8.3(Hardness , max-IS 1500 or IS 1501 (Part 1) or IS 1586) |
- |
300 |
|
NA |
8.4(Bend Test) |
- |
200 |
|
NA |
8.5(Erichsen Cupping Test) |
- |
200 |
|
NA |
10.1(Thickness, mm) |
- |
100 |
|
NA |
10.2(width, mm) |
- |
100 |
|
NA |
10.3(Length, mm) |
- |
100 |
|
NA |
10.4(Flatness,mm) |
- |
100 |
|
NA |
10.5(Camber, mm) |
- |
100 |
|
NA |
11(Surface Finish) |
- |
100 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- - |
54 |
IS 446 (2017) |
Rubber hoses, textile - Reinforced, for compressed air - Specification (Fifth Revision) |
- |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 4(Classification) |
- |
250 |
|
NA |
Cl 5(Materials and construction) |
- |
500 |
|
NA |
Cl 6.1 & Table 1(Internal diameters and tolerances) |
- |
250 |
|
NA |
Cl 6.2(Concentricity) |
- |
250 |
|
NA |
Cl 6.3(Tolerance on length) |
- |
250 |
|
NA |
Cl 6.4(Minimum thickness of lining and cover-Type 1 ) |
- |
100 |
|
NA |
Cl 6.4(Minimum thickness of lining and cover-Type 1 ) |
- |
100 |
|
NA |
Cl 6.4(Minimum thickness of lining and cover-Type 2 ) |
- |
100 |
|
NA |
Cl 6.4(Minimum thickness of lining and cover-Type 2 ) |
- |
100 |
|
NA |
Cl 6.4(Minimum thickness of lining and cover-Type 3) |
- |
100 |
|
NA |
Cl 6.4(Minimum thickness of lining and cover-Type 3) |
- |
100 |
|
NA |
Cl 7.1 & Table 2(Minimum tensile strength) |
- |
100 |
|
NA |
Cl 7.1 & Table 2(Minimum tensile strength) |
- |
1000 |
|
NA |
7.1, Table 2(Elongation at Break of Lining of all types) |
- |
1000 |
|
NA |
7.1, Table 2(Elongation at Break of Cover of all types) |
- |
500 |
|
NA |
Cl 7.1 & Table 2(Resistance to ageing-Change in tensile strength from
original value (max.) ) |
- |
500 |
|
NA |
7.1, Table 2(Accelerated Ageing for all types: Change in Tensile Strength of Cover of its original value) |
- |
500 |
|
NA |
Cl 7.1 & Table 2(Resistance to ageing-Change in elongation at break
from original value (max.)
original value (max.) ) |
- |
500 |
|
NA |
7.1, Table 2(Accelerated Ageing for all types: Change in Elongation of Cover of its original value) |
- |
500 |
|
NA |
Cl 7.1 & Table 2(Resistance to liquids-Increase in volume (class A)) |
- |
500 |
|
NA |
Cl 7.1 & Table 2(Resistance to liquids-Increase in volume (class A)) |
- |
500 |
|
NA |
Cl 7.1 & Table 2(Resistance to liquids-Increase in volume (max.)
(class B only) ) |
- |
500 |
|
NA |
Cl 7.1 & Table 2(Resistance to liquids-Increase in volume (max.)
(class B only) ) |
- |
500 |
|
NA |
Cl 7.1 & Table 2(Resistance to liquids-Increase in volume (max.)
(class C only) ) |
- |
500 |
|
NA |
Cl 7.1 & Table 2(Resistance to liquids-Increase in volume (max.)
(class C only) ) |
- |
500 |
|
NA |
7.2, Table 3(Proof Pressure at 23°C for type 1) |
- |
500 |
|
NA |
7.2, Table 3(Proof Pressure at 23°C for type 2) |
- |
300 |
|
NA |
7.2, Table 3(Proof Pressure at 23°C for type 3) |
- |
300 |
|
NA |
7.2, Table 3(Change in Length at Maximum working Pressure) |
- |
300 |
|
NA |
7.2, Table 3(Change in Diameeter at Maximum working Pressure) |
- |
300 |
|
NA |
7.2, Table 3(Minimum Bursting Pressure for type 1) |
- |
300 |
|
NA |
7.2, Table 3(Minimum Bursting Pressure for type 2) |
- |
300 |
|
NA |
7.2, Table 3(Minimum Bursting Pressure for type 3) |
- |
300 |
|
NA |
7.2, Table 3(Adhesion between Components- Lining and Reinforcement) |
- |
300 |
|
NA |
7.2, Table 3(Adhesion between Components- Reinforcement layers) |
- |
300 |
|
NA |
7.2, Table 3(Adhesion between Components- Cover and Reinforcement) |
- |
300 |
|
NA |
7.2, Table 3(Ozone Resistance) |
- |
400 |
|
NA |
7.2, Table 3(Flexibility at 23°C) |
- |
400 |
|
NA |
7.2, Table 3(Low temperature Flexibility) |
- |
1000 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- REVISED IS 446:2017
included w.e.f.
11.12.2018. |
55 |
IS 2396 (2017) |
Rubber hoses and hose assemblies for measured fuel dispensing - Specification (Fourth Revision) |
- |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3(Material and Construction) |
- |
1000 |
|
NA |
6, Table 2(Proof Pressure- IS:443 (Part 3)) |
- |
1000 |
|
NA |
6, Table 2(Burst Pressure- IS:443 (Part 3)) |
- |
500 |
|
NA |
6, Table 2(Volumetric Expansion (Type 1 & 2)) |
- |
500 |
|
NA |
6, Table 2(Volumetric Expansion (Type 3)) |
- |
500 |
|
NA |
6, Table 2(Adhesion between Components on unaged hoses -IS:3400 (Part 24)) |
- |
500 |
|
NA |
6, Table 2(Adhesion between Components on aged hoses -IS:3400 (Part 24)) |
- |
500 |
|
NA |
6, Table 2(Ambient Temperature Flexibility) |
- |
1000 |
|
NA |
6, Table 2(Low Temperature Flexibility) |
- |
1000 |
|
NA |
6, Table 2(Tensile Strength, Lining (Rubber)) |
- |
1500 |
|
NA |
6, Table 2(Tensile Strength, Cover (Rubber)) |
- |
1500 |
|
NA |
6, Table 2(Tensile Strength, Lining (TPE)) |
- |
1500 |
|
NA |
6, Table 2(Tensile Strength, Cover (TPE)) |
- |
1500 |
|
NA |
6, Table 2(Accelerated ageing-Change in Tensile Strength for Lining of Rubber) |
- |
1000 |
|
NA |
6, Table 2(Accelerated ageing-Change in Tensile Strength for Cover of Rubber) |
- |
1000 |
|
NA |
6, Table 2(Accelerated ageing-Change in Tensile Strength for Lining of TPE) |
- |
1000 |
|
NA |
6, Table 2(Accelerated ageing-Change in Tensile Strength for Cover of TPE) |
- |
1000 |
|
NA |
6, Table 2(Accelerated ageing-Change in Elongation at break for Lining of Rubber) |
- |
1000 |
|
NA |
6, Table 2(Accelerated ageing-Change in Elongation at break for Cover of Rubber) |
- |
1000 |
|
NA |
6, Table 2(Accelerated ageing-Change in Elongation at break for Lining of TPE) |
- |
1000 |
|
NA |
6, Table 2(Accelerated ageing-Change in Elongation at break for Cover of TPE) |
- |
1000 |
|
NA |
6, Table 2(Abrasion Resistance (Cover Compound)) |
- |
1500 |
|
NA |
6, Table 2(Resistance to Liquid-Lining Swell ; 70 h at 23°C in Liquid C- IS:3400 (Part 6)) |
- |
1000 |
|
NA |
6, Table 2(Resistance to Liquid-Lining Swell ; 70 h at 40°C in type 3 Oxygenated fuel- IS:3400 (Part 6)) |
- |
1000 |
|
NA |
6, Table 2(Resistance to Liquid-Lining Swell ; 70 h at 100°C in oil No 3- IS:3400 (Part 6)) |
- |
1000 |
|
NA |
6, Table 2(Resistance to Liquid-Lining Extracted matter ; 70 h at 23°C in Liquid C- IS:3400 (Part 6)) |
- |
1000 |
|
NA |
6, Table 2(Resistance to Liquid-Lining Extracted matter ; 70 h at 40°C in type 3 Oxygenated fuel- IS:3400 (Part 6)) |
- |
1000 |
|
NA |
6, Table 2(Resistance to Liquid-Cover Swell ; 70 h at 23°C in Liquid B- IS:3400 (Part 6)) |
- |
1000 |
|
NA |
6, Table 2(Ozone Resistance of Cover-IS:443 (Part 1); method 1 or method 2, depending on Bore size) |
- |
2500 |
|
NA |
6, Table 2(Electrical Resistance using electrically conducting compounds- IS:443 (Part 4); without liquid inside hose in straight position) |
- |
1000 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- REVISED IS 2396:2017
included w.e.f.
11.12.2018. |
56 |
IS 6911 (2017) |
Stainless steel plate, sheet and strip - Specification (Second Revision) |
- |
-
|
17000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 7.1 & 7.2 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
NA |
Cl. 7.1 & 7.2 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
NA |
Cl. 7.1 & 7.2 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
NA |
Cl. 7.1 & 7.2 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
NA |
Cl. 7.1 & 7.2 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
NA |
Cl. 7.1 & 7.2 Table 1(Molybdenum -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
NA |
Cl. 7.1 & 7.2 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
NA |
Cl. 7.1 & 7.2 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
NA |
Cl. 7.1 & 7.2 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
NA |
Cl. 7.1 & 7.2 Table 1(Copper -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
NA |
Cl. 7.1 & 7.2 Table 1(Others-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
600 |
|
NA |
Cl. 7.1 & 7.2 Table 1(Titanium-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
NA |
Cl. 7.1 & 7.2 Table 1(Niobium-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
NA |
Cl.12(Corrosion Resistance- IS 10461(Part1)) |
- |
1000 |
|
NA |
Cl.12(Corrosion Resistance- IS 10461(Part2)) |
- |
1000 |
|
NA |
6(Freedom from defects , IS 6911) |
- |
100 |
|
NA |
10.1,Table 4&Table 6(Tensile Test - IS 1608(Pt -1)) |
- |
1000 |
|
NA |
10.2,Table 4&Table 5(Hardness Test- IS 1500(Pt -1),IS 1501 (Pt-1),IS 1586 (Pt -1)) |
- |
1000 |
|
NA |
10.3(Bend Test - IS 1599) |
- |
500 |
|
NA |
11,Table 7(Erichsen cupping test-IS 10175) |
- |
500 |
|
NA |
15(Surface Finish) |
- |
100 |
|
NA |
17(Dimension and tolerance) |
- |
200 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- All grades except X02Cr24Ni22Mo7N & X02Cr24Ni17Mo4Mn6N |
57 |
IS 17153 (2019) |
Domestic gas stoves for use with piped natural gas (PNG) - Specification |
- |
-
|
43000 View breakup
Single Burner
SS Body – Rs.21000/-
Glass Top – Rs. 24000/-
Double Burner
SS Body – Rs. 26000/-
Glass Top – Rs. 29000/-
Three Burner
SS Body – Rs. 31000/-
Glass Top – Rs. 34000/-
Four Burner
SS Body – Rs. 36000/-
Glass Top – Rs. 39000/-
Five Burner
SS Body – Rs. 40000/-
Glass Top – Rs. 43000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(The construction of all the parts of equipment shall be sound and of high standard of workmanship and appropriate finish. The construction shall ensure durability and shall comply with the safety requirements.) |
- |
100 |
|
OK |
4.2(Rivets, Fastening screws and plugs , etc. shall not lead into gas passages.) |
- |
100 |
|
OK |
4.3(No pressure regulator shall be included as part of the stove.) |
- |
100 |
|
OK |
5.1(The appliance shall be free from swarf, grit and other foreign matters.) |
- |
100 |
|
OK |
5.1(If flexible tubing is used, it shall not be fitted on the outlet side of any control which is capable of cutting of the gas completely, except where screwed metal connection are fitted.) |
- |
100 |
|
OK |
5.1(The use of low pressure rubber or plastic tubing fitted or pushed on nozzle is not recommended.) |
- |
100 |
|
OK |
5.1.1(Plastic components which are liable to heating (For example, tap handles push buttons etc.) shall be free of fissures, distortion, blemishes and discolouration) |
- |
100 |
|
OK |
5.2(The burner parts shall not melt or distort when burner is operated with flames flashed back for half an hour in the mixing tube.) |
- |
100 |
|
OK |
5.3(Mercurous Nitrate test for copper and copper alloy Parts) |
- |
500 |
|
OK |
5.4(Change in weight or volume of a non metallic material, when immerse in n-Pentane or PNG for 72 hours) |
- |
500 |
|
OK |
5.5(The main body of the burner including mixer head, mixing tube and burner head shall be of substantial and durable construction) |
- |
500 |
|
OK |
5.6(Meltiing poin of metal used in oven, griller or auxilliary or anyother combination) |
- |
100 |
|
OK |
5.7(Drip tray if provided shall be made of non-corrosive material) |
- |
100 |
|
OK |
5.8.1(Toughened glass top including their edges or corners shall not have fissures or scratches) |
- |
200 |
|
OK |
5.8.2(The means to hold the glass top of the gas stove shall not allow any stress or risk of mechanical change to the glass top.) |
- |
200 |
|
OK |
5.8.2(The toughened glass top shall ensure durability against damage in normal use) |
- |
200 |
|
OK |
5.8.2(Pan support for an uncovered burner in contact with the glass ceramic surface.The surface area of the pan support in contact with the glass ceramic) |
- |
200 |
|
OK |
5.8.3(Toughened glass shall fragment into small particles.) |
- |
200 |
|
OK |
5.8.3(The number of glass fragments contained in a 50 mm side square, when tested as Cl. 15.2) |
- |
200 |
|
OK |
6.1(The appliance, including all the component parts, shall be easy to clean and maintain in good working order, there shall be easy access to the accessories and controls for maintenance and adjustment.) |
- |
100 |
|
OK |
6.2(the parts of the burner shall not become disconnected during operation of the appliance.) |
- |
100 |
|
OK |
6.2(The relative distance between the centres of the adjoining burner-) |
- |
100 |
|
OK |
6.3(Burner ports shall be so designed and located that in normal use spilage of food shall not cause internal fouling of mixing tube and or blockage of injector jet.) |
- |
100 |
|
OK |
6.4(Burners and parts of Burner only of same rating , model and make shall be interchangeable or replaceable without effecting performance.) |
- |
100 |
|
OK |
6.5(Parts, which are intented to be removable by the user, shall be easy to replace correctly and difficult to assemble incorrectly.) |
- |
50 |
|
OK |
6.6(All nuts, bolts and fittings having spanner flats shall be capable of being moved by suitable spanner or be readily accessible to an adjustable spanner.) |
- |
50 |
|
OK |
6.7(Thickness of Sheet) |
- |
100 |
|
OK |
7(Rigidity and Stability : The appliance shall be so designed that it remains stable and shall not be easily overturned.) |
- |
900 |
|
OK |
8.1(The Finish of exposed parts shall be durable, easy to clean and not subject to excessive deterioration in normal use.) |
- |
100 |
|
OK |
8.1(Parts, which will come in contact with the foodstuff, shall be capable of being hygienically cleaned.) |
- |
100 |
|
OK |
8.1(The finishes shall, on visual examination, show no defects, such as pin-holes, blisters, roughness or exposed area of metal, which give rise to undualy rapid deterioration in use.) |
- |
100 |
|
OK |
8.2(Vitreous enameled component shall meet the requirement when tested in accordance with Annex E of IS:5116) |
- |
50 |
|
OK |
8.3(Thickness of Nickel coating of the top flat surface of the body of electroplated stove.) |
- |
50 |
|
OK |
8.3.1(Thickness of Chromium coating) |
- |
50 |
|
OK |
8.3.2(Adhesion Test) |
- |
50 |
|
OK |
8.3.3(Corrosion Resistance test) |
- |
50 |
|
OK |
8.4 (a)(Resistance to Abrasion) |
- |
100 |
|
OK |
8.4 (b)(Resistance to Heating) |
- |
100 |
|
OK |
8.5(Concealed Gas Supplies: Concealed tubular fittings liable to corrode shall be protected by bituminous paint or other equally protective material.) |
- |
50 |
|
OK |
8.6(All springs, screws, nuts and bolts which are visible or to be removed for maintenance, shall be of corrosion-resistant material or treated to resist corrosion.) |
- |
25 |
|
OK |
8.7(The external Finished surfaces shall be easily cleanable.) |
- |
25 |
|
OK |
9.1(The Appliance shall have at least one tap for each burner) |
- |
100 |
|
OK |
9.2(The 'ON' "OFF" and any fixed position of tap handles shall be clearly and durably indicated or shall be obvious by design or position else some indication shall be provided.) |
- |
50 |
|
OK |
9.2(All Taps shall close in the same direction. The direction of rotation of knob from off-on-simmer shall be anti-clockwise.) |
- |
50 |
|
OK |
9.2(Taps shall be designed so that when placed in any position and viewed from a distance of 3 m, will definitely indicate whether the valve is open, closed or in intermediate position.) |
- |
50 |
|
OK |
9.3(When Taps are fitted with adjustable stops, there shall be means of looking the stops in position. If screws are used for this purpose, they shall not lead into gas passages.) |
- |
50 |
|
OK |
9.4(Preferably all taps (Excluding pilot taps) should lock in the off position, but in all cases it shall be impossible to handle or tap to move accidentally…. ) |
- |
50 |
|
OK |
9.5(Taps shall be so made that in normal use and reasonable application of lubricant, the gas passages do not become blocked.) |
- |
50 |
|
OK |
9.5.1(Taps shall be lubricated with suitable grease, resistant to the action of the gas and capable of operating at the maximum temperature of 110°C.) |
- |
50 |
|
OK |
9.6(Each taper plug tap shall be spring loaded to maintain a gas tight fit. Helical springs fitted in taps and valves shall have flattened ends, which shall be rounded before fitting.) |
- |
50 |
|
OK |
9.7(Dimension of Taper plugs in off position:) |
- |
0 |
|
OK |
9.7(A) |
- |
25 |
|
OK |
9.7(B) |
- |
25 |
|
OK |
9.7(C) |
- |
25 |
|
OK |
9.7(D) |
- |
25 |
|
OK |
9.7(A1) |
- |
25 |
|
OK |
9.7(B1) |
- |
25 |
|
OK |
9.7(C1) |
- |
25 |
|
OK |
9.8(All controls or taps shall be easy to operate at all temperatures normally attained in use) |
- |
25 |
|
OK |
9.9(Screws nuts etc., which regulate the tension of taps valve or springs shall not loosen in operation of the appliance. It shall not be possible to cause a leak during normal manual operation of tap.) |
- |
50 |
|
OK |
9.1(Screw-down valves shall be so designed that it is impossible to withdraw completely the valve stem in the normal operation of the tap.) |
- |
50 |
|
OK |
9.11(Taps having an 'OFF' position shall have positive stops at the 'OFF' and simmer position except that special purpose taps (for appliance incorporating auto or self ignition device)) |
- |
25.01 |
|
OK |
9.11.1(Simmer flame shall be obtained by fixed simmer orifice.) |
- |
50 |
|
OK |
9.12(The noting means adopted shall be sufficiently robust to withstand normal use without distortion or damage.) |
- |
25 |
|
OK |
10.1(The Injector Jets shall be fixed calibrated type and it shall not be possible to loosen them without the use of tools.) |
- |
100 |
|
OK |
10.1(Dimension- Across Flats) |
- |
100 |
|
OK |
10.1(Dimension- Projection from the face of mounting, Nominal) |
- |
100 |
|
OK |
10.1(Dimension- Threads) |
- |
100 |
|
OK |
10.1.1(Injector Jet shall be made of metal , with or without ceramic tip. The melting point of the metal shall not be less than 650°C) |
- |
100 |
|
OK |
10.2(The Size of the jet in Litres per hour of flow of PNG at STP conditions shall be impressed upon it.) |
- |
400 |
|
OK |
11.1(The construction of the burners and the assembly shall allow their dismantling from the supports easily with or without the use of tools) |
- |
100 |
|
OK |
11.2(The Burner supports shall be rigid and shall be fixed in their place. Their construction shall ensure the stability of the burners and shall prevent their undue movement in a horizontal plane.) |
- |
100 |
|
OK |
11.3(The tightness of the joints in the burner assembly shall not be depended upon adhesives or any kind of packing.) |
- |
100 |
|
OK |
11.4(If primary air regulators are used, they shall be so designed that they are not easily maladjusted by the user and the construction shall be such that primary air adjustment can be made with the burner in place.) |
- |
100 |
|
OK |
11.5(If the burner is made and assembled in two or more parts they shall be so designed to provide proper self locating arrangement so that they are always reassembled to its original design preventing any maladjustment in their assembly. This shall also be applicable for primary air regulators.) |
- |
100 |
|
OK |
11.6(For Burners having centre flame, provision shall be made to protect the centre flame from pan resting directly on burner top and smothering the centre flame. ) |
- |
100 |
|
OK |
11.7(The appliance comprising two or more burners shall include one burner having a rating of at least 1450 kCal/hr, based on net calorific value of the gas (When using domestic PNG)) |
- |
300 |
|
OK |
12.1(The design of the pan supports shall be such that it is practicable to support a pan of 100 mm diameter over at least one top burner without the use of loose rings and such that 125 mm diameter vessel remains stable over each burner. ) |
- |
300 |
|
OK |
12.1(Prongs of the Support shall have suitable taper to accommodate round bottom pans.) |
- |
300 |
|
OK |
12.1.1(Loose Pan support shall be so designed that it is not possible to place them firmly in other than proper position) |
- |
200 |
|
OK |
12.1.2(The material of the pan support shall be metallic.) |
- |
100 |
|
OK |
13(All gas carrying parts of the appliances should be sound and these parts when connected to form complete assembly shall also be sound against any gas leakage. The complete assembly shall be checked at 14.71 kN/m²) |
- |
900 |
|
OK |
14.1(Nozzle shall be machined from free cutting brass, MS, SS, Zinc) |
- |
50 |
|
OK |
14.2(Where Nozzles for flexible tubing are fitted, they shall be so positioned as to facilitate fitting of the tubing and also to prevent heating of the tubing to more than 60°C) |
- |
50 |
|
OK |
14.2(Shape of Nozzles as per fig. 3 : (a)) |
- |
0 |
|
OK |
14.2((b)) |
- |
50 |
|
OK |
14.2(( c)) |
- |
50 |
|
OK |
14.2((d)) |
- |
50 |
|
OK |
14.2((e)) |
- |
50 |
|
OK |
14.3(Screwed gas Inlet and outlet connections shall confirm to IS:554, Declared by party) |
- |
100 |
|
OK |
14.4(The wall thickness of main gas rail) |
- |
100 |
|
OK |
14.4(The pipe/tube used for main gas rail shall be of mild steel) |
- |
100 |
|
OK |
14.4(The external surface of the gas rail shall be treated to resist corrosion) |
- |
100 |
|
OK |
14.4(Any other connection made from the main gas rail shall be only metallic.) |
- |
100 |
|
OK |
14.5(The position of the gas inlet shall allow connection to a gas supply on either side of the appliances, the rear end or bottom is also permitted. It shall be possible to change gas inlet from one side to other side easily by standard tools.) |
- |
100 |
|
OK |
15(Vertical Deflection) |
- |
300 |
|
OK |
15(Length wise deflection) |
- |
350 |
|
OK |
15(Width wise deflection) |
- |
350 |
|
OK |
15.1(Verification of the strength of the gas stove surface of the toughened glass top against thermal stress) |
- |
100 |
|
OK |
15.2(Fragmentation test of the toughened glass to ) |
- |
100 |
|
OK |
17.1(Rating Declared) |
- |
500 |
|
OK |
17.1( Burner-1) |
- |
200 |
|
OK |
17.1( Burner-2) |
- |
200 |
|
OK |
17.1( Burner-3) |
- |
200 |
|
OK |
17.1(Burner-4) |
- |
200 |
|
OK |
17.1(Burner-5) |
- |
200 |
|
OK |
17.1.2(Total Gas Consumption) |
- |
200 |
|
OK |
17.2(Sim Rating Declared) |
- |
100 |
|
OK |
17.2(Burner-1) |
- |
100 |
|
OK |
17.2(Burner-2) |
- |
100 |
|
OK |
17.2(Burner-3) |
- |
100 |
|
OK |
17.2(Burner-4) |
- |
100 |
|
OK |
17.2(Burner-5) |
- |
100 |
|
OK |
17.3(When the gas consumption of the burner is reduced to simmer, the flame shall not extinguish, blow off, strike back or form soot, when tested with commercial PNG at 21 mbar gas inlet pressure.) |
- |
200 |
|
OK |
18.1(There shall be easy and safe access of lighting each burner by matchstick and it shall be easy to see that the burner is lighted) |
- |
150 |
|
OK |
18.1(Where the burner or burners are lighted by automatic ignition (Battery of flint operated or by a pilot flame , it shall not be possible for gas to be admitted to the main burner without being smoothly ignited by the pilot flame. Each burner should be at room temperature at the begining of the test and should be tested in turn. ) |
- |
150 |
|
OK |
18.2(if the flame is applied to any of the outer row of the burner ports when the gas is flowing , flame travel shall be complete……..) |
- |
100 |
|
OK |
18.3(When the burner is ignited from a pilot flame and/or by an electric/electronic method, the ignition and flame travel shall be smooth at pressure……..) |
- |
200 |
|
OK |
18.4.1(The flame failure device if provided shall confirm to IS:5116) |
- |
600 |
|
OK |
19.1(It shall be possible to operate stove with taps fully open at gas inlet pressure , without the flame extinguishing, blowing off or striking back and without the formation of soot.) |
- |
200 |
|
OK |
19.1.1(When the gas consumption of the burner is reduced to simmer after operating half an hour on full ON flame shall not extinguish, blow off, strike back or form soot at 21 mbar gas inlet pressure.) |
- |
200 |
|
OK |
19.2(Pilot Flame shall be Stable without lifting or soot deposition at gas inlet pressure from 20-25 gf/cm2) |
- |
100 |
|
OK |
19.3(Fixed Min Pilot flame shall be sufficient to relight the main burner at the 21 mbar gas inlet pressure.) |
- |
100 |
|
OK |
20(Ignition of Burner flame, their operation and turning off shall not give rise to undue excessive noise during the operation.) |
- |
600 |
|
OK |
21(When operated at pressure 20-25 gf/cm2 for half an hour flame shall be reduced to simmer and then brought back to full on, operation shall be repeated five times, no flash back shall occur during the test.) |
- |
600 |
|
OK |
22(When operated at pressure 20-25 gf/cm2 , for one at full on position, no soot shall be deposited on burner or on the bottom of the vessel.) |
- |
900 |
|
OK |
23(When operated at pressure 20-25 gf/cm2 , there shall be no extinction of flame on any of the burneroperating at the max of the burner, when the appliance is placed in normal current of air with velocity of 2 m/s.) |
- |
900 |
|
OK |
24(Burner-1) |
- |
1600 |
|
OK |
24(Burner-2) |
- |
1600 |
|
OK |
24(Burner-3) |
- |
1600 |
|
OK |
24(Burner-4) |
- |
1600 |
|
OK |
24(Burner-5) |
- |
1600 |
|
OK |
25.1(Rise of Temperature above room temperature in (Wall, Floor, Ceiling), after two hours of operation) |
- |
300 |
|
OK |
25.1(Temperature of the portion of the surface other than the working surface likely to be touched accidentally.) |
- |
300 |
|
OK |
25.1(Temperature of the surface in normal use) |
- |
300 |
|
OK |
25.1(Temperature of synthetic rubber diaphragm in gas carrying components) |
- |
10 |
|
OK |
25.2(With the Burner lighted on full on, the flame temperature at a height of H+20 mm) |
- |
690 |
|
OK |
26(Burner-1) |
- |
3500 |
|
OK |
26(Burner-2) |
- |
3500 |
|
OK |
26(Burner-3) |
- |
3500 |
|
OK |
26(Burner-4) |
- |
3500 |
|
OK |
26(Burner-5) |
- |
3500 |
|
OK |
5.8.1(Materials) |
- |
1000 |
|
OK |
5.8.2 (a)(Materials) |
- |
100 |
|
OK |
5.8.2 (a)(Materials) |
- |
100 |
|
OK |
5.8.2 (a)(Materials) |
- |
100 |
|
OK |
5.8.2 (a)(Materials) |
- |
100 |
|
OK |
5.8.2 (a)(Materials) |
- |
100 |
|
OK |
5.8.2 (b)(Materials) |
- |
100 |
|
OK |
5.8.2 (c )(Materials) |
- |
100 |
|
OK |
5.8.2 (d)(Materials) |
- |
100 |
|
OK |
5.8.2 (e)(Materials) |
- |
100 |
|
OK |
5.8.2 (e)(Materials) |
- |
100 |
|
OK |
5.8.2 (e)(Materials) |
- |
100 |
|
OK |
5.8.2 (e)(Materials) |
- |
100 |
|
OK |
5.8.3 (a)(Materials) |
- |
200 |
|
OK |
5.8.3 (b)(Materials) |
- |
200 |
|
OK |
5.8.3 (c)(Materials) |
- |
100 |
|
OK |
5.8.3 (d)(Materials) |
- |
100 |
|
OK |
5.8.3 (e)(Materials) |
- |
2000 |
|
OK |
5.8.3 (f)(Materials) |
- |
100 |
|
OK |
|
Complete
|
|
05 Oct, 2025 |
- With Amendment-2. Included w.e.f. 14-07-2022. |
58 |
IS 740 (1977) |
Specification for wrought aluminium and aluminium alloy rivet stock for general engineering purposes (Second Revision) |
- |
-
|
6000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1,
Table 1of IS:740 (Designation 19000)(Copper) |
- |
625 |
|
- |
4.1,
Table 1of IS:740 (Designation 24345)(Copper) |
- |
550 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Copper) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Copper) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Copper) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 65032)(Copper) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 19000)(Magnesium) |
- |
625 |
|
- |
4.1,
Table 1of IS:740 (Designation 19000)(Silicon) |
- |
625 |
|
- |
4.1,
Table 1of IS:740 (Designation 19000)(Iron) |
- |
625 |
|
- |
4.1,
Table 1of IS:740 (Designation 19000)(Manganese) |
- |
625 |
|
- |
4.1,
Table 1of IS:740 (Designation 19000)(Zinc) |
- |
625 |
|
- |
4.1,
Table 1of IS:740 (Designation 19000)(Aluminium) |
- |
625 |
|
- |
4.1,
Table 1of IS:740 (Designation 19000)(Cu+Mg+Si+Fe+Mn+Zn) |
- |
625 |
|
- |
4.1,
Table 1of IS:740 (Designation 24345)(Magnesium) |
- |
550 |
|
- |
4.1,
Table 1of IS:740 (Designation 24345)(Silicon) |
- |
550 |
|
- |
4.1,
Table 1of IS:740 (Designation 24345)(Iron) |
- |
550 |
|
- |
4.1,
Table 1of IS:740 (Designation 24345)(Manganese) |
- |
550 |
|
- |
4.1,
Table 1of IS:740 (Designation 24345)(Zinc) |
- |
550 |
|
- |
4.1,
Table 1of IS:740 (Designation 24345)(Titanium and or other grain refining elements) |
- |
550 |
|
- |
4.1,
Table 1of IS:740 (Designation 24345)(Chromium) |
- |
550 |
|
- |
4.1,
Table 1of IS:740 (Designation 24345)(Aluminium) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Magnesium) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Silicon) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Iron) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Manganese) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Zinc) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Titanium and or other grain refining elements) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Chromium) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Cr+Mn) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Aluminium) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Magnesium) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Silicon) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Iron) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Manganese) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Zinc) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Titanium and or other grain refining elements) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Chromium) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Cr+Mn) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Aluminium) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Magnesium) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Silicon) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Iron) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Manganese) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Zinc) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Titanium and or other grain refining elements) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Chromium) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Cr+Mn) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Aluminium) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 65032)(Magnesium) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 65032)(Silicon) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 65032)(Iron) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 65032)(Manganese) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 65032)(Zinc) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 65032)(Titanium and or other grain refining elements) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 65032)(Chromium) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 65032)(Either Cr or Mn shall present) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation 65032)(Aluminium) |
- |
500 |
|
- |
4.1,
Table 1of IS:740 (Designation & Condition 19000, '112')(Tensile Strength of Size upto and including 12 mm) |
- |
1000 |
|
- |
4.1,
Table 1of IS:740 (Designation & Condition 24345, 'W')(Tensile Strength of Size upto and including 12 mm) |
- |
1000 |
|
- |
4.1,
Table 1of IS:740 (Designation & Condition 53000, 'O or M')(Tensile Strength of Size upto and including 25 mm) |
- |
1000 |
|
- |
4.1,
Table 1of IS:740 (Designation & Condition 53000, 'OD')(Tensile Strength of Size upto and including 25 mm) |
- |
1000 |
|
- |
4.1,
Table 1of IS:740 (Designation & Condition 55000, 'O or M')(Tensile Strength of Size upto and including 25 mm) |
- |
1000 |
|
- |
4.1,
Table 1of IS:740 (Designation & Condition 55000, 'OD')(Tensile Strength of Size upto and including 25 mm) |
- |
1000 |
|
- |
4.1,
Table 1of IS:740 (Designation & Condition 64430, 'W')(Tensile Strength of Size upto and including 25 mm) |
- |
1000 |
|
- |
4.1,
Table 1of IS:740 (Designation & Condition 65032, 'W')(Tensile Strength of Size upto and including 25 mm) |
- |
1000 |
|
- |
|
Complete
|
|
05 Oct, 2025 |
- - |
59 |
IS 447 (1988) |
Specification for rubber hose for welding (Fourth Revision) |
- |
-
|
6000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 3.2 - Table 1(Bore size) |
- |
100 |
|
NA |
Cl. 3.2 - Table 1(Lining Thickness) |
- |
100 |
|
NA |
Cl. 3.2 - Table 1(Cover Thickness) |
- |
100 |
|
NA |
Cl. 3.2 - Table 1(Length %) |
- |
100 |
|
NA |
Cl. 3.3 - Table 2(Tensile strength - Lining MPA) |
- |
500 |
|
NA |
Cl. 3.3 - Table 2(Tensile strength - Cover Mpa) |
- |
500 |
|
NA |
Cl. 3.3 - Table 2(Elongation at break - Lining %) |
- |
500 |
|
NA |
Cl. 3.3 - Table 2(After Ageing Tensile strength - Lining %) |
- |
500 |
|
NA |
Cl. 3.3 - Table 2(After Ageing Tensile strength - Cover %) |
- |
500 |
|
NA |
Cl. 3.3 - Table 2(After Ageing Elongation at break - Lining %) |
- |
500 |
|
NA |
Cl. 3.3 - Table 2(After Ageing Elongation at break - Cover) |
- |
500 |
|
NA |
Cl. 3.4 - Table3(Pressure Tests) |
- |
1000 |
|
NA |
Cl. 3.4 - Table3(Adhesion, KN/m Min) |
- |
1000 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- - |
60 |
IS 12585 (1988) |
Specification for thermoplastic hoses (Textile Reinforced) for water - General purpose |
- |
-
|
7313 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 3(Types) |
- |
2000 |
|
NA |
Cl 4.1(Construction) |
- |
2000 |
|
NA |
Cl 4.2(Dimensions & Tolerances) |
- |
2000 |
|
NA |
Cl 4.3.1 & Appendix A(Loss in Mass on Heating) |
- |
2000 |
|
NA |
Cl 4.3.2(Adhesion) |
- |
500 |
|
NA |
Cl 4.3.3(Pressure Requirements) |
- |
500 |
|
NA |
Cl 4.3.4(Minimum Bend Radius) |
- |
1000 |
|
NA |
Cl 4.3.5(Low Temperature Flexibility) |
- |
2000 |
|
NA |
|
Complete
|
|
05 Oct, 2025 |
- - |