| 3631 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 19084 (2024) |
Plastic Containers and Closures for Homoeopathic Pharmaceutical Preparations � Specification |
Mech: Screw neck or drop-dispensing plastic bottle: 500 ml & Jar: 500 ml, 1000 ml, 2000 ml |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.3 (Capacity) |
- |
|
|
|
| 4.4 (Design, Shape and Dimension) |
- |
|
|
|
| 4.6 (Mass) |
- |
|
|
|
| 4.8 (Wall Thickness) |
- |
|
|
|
| 4.9 (Workmanship and Finish) |
- |
|
|
|
| 5.2 (Leakage Test) |
- |
|
|
|
| 5.3 (Drop Impact Test) |
- |
|
|
|
| 5.4 (Collapsibility Test) |
- |
|
|
|
| 5.7 (Verticality test) |
- |
|
|
|
| 5.8 (Transparency) |
- |
|
|
|
| 5.9 (Stack Load Test) |
- |
|
|
|
| Cl. 4.5 (Odour) |
- |
|
|
|
| Cl. 4.7 (Overall Migration - IS 9845) |
- |
|
|
|
| Cl. 5.1 (Environmental Stress - Crack Resistance - Method I of IS 8747) |
- |
|
|
|
| Cl. 5.6 (Container Material Test - Clause 4.3.2 of IS 7803- water soluble impurities contents, Table 1, S.No iv), Heavy metals (as Pb)- Annex F of IS 7803 (Part 1)) |
- |
|
|
|
| Cl. 5.6 (Container Material Test - Clarity of Aqueous Extract - Clause 4.3.1 of IS 7803 (Part 1)) |
- |
|
|
|
| Cl. 5.6 (Container Material Test - Clause 4.3.2 of IS 7803- water soluble impurities contents, Table 1, S.No i), Oxizizable matter- Annex C of IS 7803 (Part 1)) |
- |
|
|
|
| Cl. 5.6 (Container Material Test - Clause 4.3.2 of IS 7803- water soluble impurities contents, Table 1, S.No ii), Sulphate ions (SO4)- Annex D of IS 7803 (Part 1)) |
- |
|
|
|
| Cl. 5.6 (Container Material Test - Clause 4.3.2 of IS 7803- water soluble impurities contents, Table 1, S.No iii), Ammonium ions (NH4)- Annex E of IS 7803 (Part 1)) |
- |
|
|
|
| Cl. 5.6 (Container Material Test - Clause 4.3.2 of IS 7803- water soluble impurities contents, Table 1, S.No v), Chloride ions (Cl-)- Annex G of IS 7803 (Part 1)) |
- |
|
|
|
| Cl. 5.5 (Compatibility Test - Clause 12 of IS 2798) |
- |
|
|
|
|
- |
- Mechanical- Complete (Facility available for Screw neck or drop-dispensing plastic bottle: 500 ml, Jar: 500 ml, 1000 ml, 2000 ml), Chemical- Partial
Except
Cl.4.1.1 - Material for Plastic container,
Cl.4.1.2 - Material for Plastic Closures,
Cl.4.2 - Pigments and Colorants
Sample required:
Mechanical- Quantity - 12 filled & 14 empty
Chemical- For 5,10,15 ml capacity ~ 175 pieces, For 30, 50, 100 ml capacity ~70 pieces, For 500 ml capacity - 50 pieces |
| 3632 |
Excel Surveyors Pvt. Ltd., Kolkata
| 5135906
| IS 2818 (2015) |
Textiles - Hessian - Specification (Third Revision) |
Type I - VI |
2300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1, Table 1(Weight per square meter) |
- |
350 |
|
- |
| 5.1, Table 1(Ends/dm) |
- |
100 |
|
- |
| 5.1, Table 1(Picks/dm) |
- |
100 |
|
- |
| 5.1, Table 1(Width) |
- |
150 |
|
- |
| 5.1, Table 1(Average breaking strength) |
- |
700 |
|
- |
| 5.2, Table 2(Moisture regain) |
- |
400 |
|
- |
| 5.2, Table 2(Contract weight of bale) |
- |
0 |
|
- |
| 5.2, Table 2(Contract weight of roll) |
- |
0 |
|
- |
| 5.2, Table 2(corrected net weight of bale or roll) |
- |
0 |
|
- |
| 5.2, Table 2(Length of hessian per bale) |
- |
0 |
|
- |
| 5.2, Table 2(permissible number of short pieces per bale) |
- |
0 |
|
- |
| 5.2, Table 2(Number of joints in a roll and number of such joined rolls in a consignment) |
- |
0 |
|
- |
| 5.2, Table 2(Oil content on dry de-oiled material) |
- |
500 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f.04.08.2025
Exclusion
"5.2, Table 2 (Contract weight of bale)
5.2, Table 2 (Contract weight of roll)
5.2, Table 2 (corrected net weight of bale or roll)
5.2, Table 2 (Length of hessian per bale)
5.2, Table 2 (permissible number of short pieces per bale)
5.2, Table 2 (Number of joints in a roll and number of such joined rolls in a consignment)" |
| 3633 |
Classic Testing & Research Centre (B17), Noida
| 8180826
| IS 17550 : Part 3 (2025) |
Household Refrigerating Appliances - Characteristics and Methods Of Test Part 3 Energy Consumption and Volume (First Revision) |
- |
145000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.1, Annex A(set up for energy consumption) |
- |
15000 |
|
- |
| Clause 4.2, Annex B(Steady state power consumption) |
- |
15000 |
|
- |
| Clause 4.3, Annex C(Defrost and Recovery Energy and Temperature Change) |
- |
15000 |
|
- |
| Clause 4.4, Annex D(Defrost Frequency) |
- |
15000 |
|
- |
| Clause 4.5, Annex E(Number of Test Points and Interpolation) |
- |
15000 |
|
- |
| Clause 4.6, Annex G(Load Processing Efficiency) |
- |
15000 |
|
- |
| Clause 4.7, Annex F(Specified Auxiliaries) |
- |
15000 |
|
- |
| Clause 4.8, Annex H(Volume determination) |
- |
15000 |
|
- |
| Clause 4.8.1, Annex H(Rated total volume) |
- |
15000 |
|
- |
| Clause 5, 5.1, 5.2 Table 1(TARGET TEMPERATURES FOR ENERGY DETERMINATION) |
- |
15000 |
|
- |
| Clause 6, 6.1 to 6.8(DETERMINATION OF ENERGY CONSUMPTION) |
- |
15000 |
|
- |
| Clause 4.1, Annex A(set up for energy consumption) |
- |
15000 |
|
- |
| Clause 4.2, Annex B(Steady state power consumption) |
- |
15000 |
|
- |
| Clause 4.3, Annex C(Defrost and Recovery Energy and Temperature Change) |
- |
15000 |
|
- |
| Clause 4.4, Annex D(Defrost Frequency) |
- |
15000 |
|
- |
| Clause 4.5, Annex E(Number of Test Points and Interpolation) |
- |
15000 |
|
- |
| Clause 4.6, Annex G(Load Processing Efficiency) |
- |
15000 |
|
- |
| Clause 4.7, Annex F(Specified Auxiliaries) |
- |
15000 |
|
- |
| Clause 4.8, Annex H(Volume determination) |
- |
15000 |
|
- |
| Clause 4.8.1, Annex H(Rated total volume) |
- |
15000 |
|
- |
| Clause 5, 5.1, 5.2 Table 1(TARGET TEMPERATURES FOR ENERGY DETERMINATION) |
- |
15000 |
|
- |
| Clause 6, 6.1 to 6.8(DETERMINATION OF ENERGY CONSUMPTION) |
- |
15000 |
|
- |
|
15 Oct, 2027 |
- Included w.e.f 04.09.2025 |
| 3634 |
Fire Test & Research Laboratory, Sonipat
| 8123835
| IS 2097 (2024) |
Low Expansion Foam Making Branch Pipe and Portable Foam Inductor - Specification (Third Revision) |
Low Expansion Foam Making Branch Pipe and Portable Foam Inductor |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-3.1(Foam Branches) |
- |
500 |
|
- |
| Cl-3.2(Portable Foam Inductors) |
- |
8000 |
|
- |
| Cl-4.2, Table-3 (vi)(Pick-up tube) |
- |
0 |
|
- |
| Cl-4.2, Table-3 (vii)(Dip tube/strainer) |
- |
0 |
|
- |
| Cl-3.1.4, 5.1 Table-1 (i)(Inlet Pressure at the Branch) |
- |
3000 |
|
- |
| Cl-3.1.4, 5.1 Table-1 (ii)(Discharge Capacity lpm) |
- |
3000 |
|
- |
| Cl-3.1.4, 5.1 Table-1 (iii)(Foam Compound Induction) |
- |
3000 |
|
- |
| Cl-3.1.4, 5.1 Table-1 (iv)(Minimum Range@ m) |
- |
3000 |
|
- |
| Cl-3.1.4, 5.1 Table-1 (v)(Foam Expansion at 27 °C ± 5 °C) |
- |
3000 |
|
- |
| Cl-3.1.4, 5.1 Table-1 (vi)(25 Percent Drainage Time for AFFF at 27 °C ± 5 °C) |
- |
3000 |
|
- |
| Cl-3.1.4, 5.1 Table-1 (vii)(25 Percent Drainage Time for AR-AFFF at 27 °C ± 5 °C) |
- |
3000 |
|
- |
| Cl-6(Marking) |
- |
500 |
|
- |
| Cl-3.1(Foam Branches) |
- |
0 |
|
This is repeated |
| Cl-3.2(Portable Foam Inductors) |
- |
0 |
|
This is repeated |
| Cl-4.2, Table-3 (vi)(Pick-up tube) |
- |
0 |
|
This is repeated |
| Cl-4.2, Table-3 (vii)(Dip tube/strainer) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (i)(Inlet Pressure at the Branch) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (ii)(Discharge Capacity lpm) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (iii)(Foam Compound Induction) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (iv)(Minimum Range@ m) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (v)(Foam Expansion at 27 °C ± 5 °C) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (vi)(25 Percent Drainage Time for AFFF at 27 °C ± 5 °C) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (vii)(25 Percent Drainage Time for AR-AFFF at 27 °C ± 5 °C) |
- |
0 |
|
This is repeated |
| Cl-6(Marking) |
- |
0 |
|
This is repeated |
| Cl-3.1(Foam Branches) |
- |
0 |
|
This is repeated |
| Cl-3.2(Portable Foam Inductors) |
- |
0 |
|
This is repeated |
| Cl-4.2, Table-3 (vi)(Pick-up tube) |
- |
0 |
|
This is repeated |
| Cl-4.2, Table-3 (vii)(Dip tube/strainer) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (i)(Inlet Pressure at the Branch) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (ii)(Discharge Capacity lpm) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (iii)(Foam Compound Induction) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (iv)(Minimum Range@ m) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (v)(Foam Expansion at 27 °C ± 5 °C) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (vi)(25 Percent Drainage Time for AFFF at 27 °C ± 5 °C) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (vii)(25 Percent Drainage Time for AR-AFFF at 27 °C ± 5 °C) |
- |
0 |
|
This is repeated |
| Cl-6(Marking) |
- |
0 |
|
This is repeated |
| Cl-3.1(Foam Branches) |
- |
0 |
|
This is repeated |
| Cl-3.2(Portable Foam Inductors) |
- |
0 |
|
This is repeated |
| Cl-4.2, Table-3 (vi)(Pick-up tube) |
- |
0 |
|
This is repeated |
| Cl-4.2, Table-3 (vii)(Dip tube/strainer) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (i)(Inlet Pressure at the Branch) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (ii)(Discharge Capacity lpm) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (iii)(Foam Compound Induction) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (iv)(Minimum Range@ m) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (v)(Foam Expansion at 27 °C ± 5 °C) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (vi)(25 Percent Drainage Time for AFFF at 27 °C ± 5 °C) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (vii)(25 Percent Drainage Time for AR-AFFF at 27 °C ± 5 °C) |
- |
0 |
|
This is repeated |
| Cl-6(Marking) |
- |
0 |
|
This is repeated |
| Cl-3.1(Foam Branches) |
- |
0 |
|
This is repeated |
| Cl-3.2(Portable Foam Inductors) |
- |
0 |
|
This is repeated |
| Cl-4.2, Table-3 (vi)(Pick-up tube) |
- |
0 |
|
This is repeated |
| Cl-4.2, Table-3 (vii)(Dip tube/strainer) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (i)(Inlet Pressure at the Branch) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (ii)(Discharge Capacity lpm) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (iii)(Foam Compound Induction) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (iv)(Minimum Range@ m) |
- |
0 |
|
This is repeated |
| Cl-3.1(Foam Branches) |
- |
0 |
|
This is repeated |
| Cl-3.2(Portable Foam Inductors) |
- |
0 |
|
This is repeated |
| Cl-4.2, Table-3 (vi)(Pick-up tube) |
- |
0 |
|
This is repeated |
| Cl-4.2, Table-3 (vii)(Dip tube/strainer) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (i)(Inlet Pressure at the Branch) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (ii)(Discharge Capacity lpm) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (iii)(Foam Compound Induction) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (iv)(Minimum Range@ m) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (v)(Foam Expansion at 27 °C ± 5 °C) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (vi)(25 Percent Drainage Time for AFFF at 27 °C ± 5 °C) |
- |
0 |
|
This is repeated |
| Cl-3.1.4, 5.1 Table-1 (vii)(25 Percent Drainage Time for AR-AFFF at 27 °C ± 5 °C) |
- |
0 |
|
This is repeated |
| Cl-6(Marking) |
- |
0 |
|
This is repeated |
|
31 Dec, 2026 |
- Included w.e.f 01.09.2025
Exclusion: Cl-4 (MATERIAL OF CONSTRUCTION) |
| 3635 |
Classic Testing & Research Centre (B17), Noida
| 8180826
| IS 17550 : Part 2 (2024) |
Household Refrigerating Appliances - Characteristics and Test Methods Part 2 Performance Requirements (First Revision) |
- |
315000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Storage Test) |
- |
20000 |
|
- |
| 7(Cooling Capacity Test) |
- |
20000 |
|
- |
| 8(Freezing Capacity Test) |
- |
20000 |
|
- |
| 9("Automatic Ice-Making
Capacity Test") |
- |
20000 |
|
- |
| Cl. No.4.6 & Annex A(PULL-DOWN TEST) |
- |
20000 |
|
- |
| Cl. No.4.6(b) & Annex B("Wine Storage
Appliances And
Compartments;
Storage Test") |
- |
20000 |
|
- |
| Cl. No.4.6(C) & AnnexC("Temperature Rise
Test ") |
- |
20000 |
|
- |
| Cl. No.4.6(d) & Annex D("Water Vapour Condensation
Test ") |
- |
20000 |
|
- |
|
15 Oct, 2027 |
- Included w.e.f 19.12.2025 |
| 3636 |
Dashmesh Test Lab Private Limited
| 8186926
| IS 4246 (2002) |
Domestic gas stoves for use with liquefied petroleum gases - Specification (Fifth Revision) |
ALL TYPE |
13000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.24(Annexure E)(on no account the carbon monoxidel
carbon dioxide ratio of the exhaust gases of any burner.
operating at any consumption at which the burner is
stable at gas inlet pressure from 2452 kN/m2 to
3432 kN/m2 (25 gf/cm2 to 35 gf/cm2), exceed 0.02.) |
- |
500 |
|
- |
| Cl.23(There shall be no extinction of the flames on any
of the burners operating at maximum consumption
when the appliance is placed in a general (not
localized) current of air with a velocity of 2 m/s, as
measured with a rotating vane anemometer. The
location of the appliance relative to neighboring walls
and the direction of the draught shall be varied to
correspond to likely conditions of appliance installation.
This applies for all pressures from 2452 kN/m2 to
3432 kN/m2 (25 gf/cm2 to 35 gf/cm2).) |
- |
500 |
|
- |
| 24 (Annex - E)(Combustion (CO and CO2 ratio)) |
- |
500 |
|
- |
| 4.1(Requirement) |
- |
500 |
|
- |
| 5(Materials) |
- |
2000 |
|
- |
| 6(Design for Maintenance) |
- |
500 |
|
- |
| 7(Rigidity and Stability) |
- |
500 |
|
- |
| 8(Workmanship and Finish) |
- |
500 |
|
- |
| 9(Gas Taps) |
- |
2000 |
|
- |
| 10(Injector Jets) |
- |
1500 |
|
- |
| 11(Burners) |
- |
500 |
|
- |
| 12(Burner Pan Supports) |
- |
500 |
|
- |
| 13.1(Gas Soundness) |
- |
500 |
|
- |
| 13.2(Gas Leak Detector) |
- |
500 |
|
- |
| 14(Gas Inlet Connections) |
- |
2000 |
|
- |
| 15(Strength and Rigidity) |
- |
500 |
|
- |
| 16(General Conditions of Test) |
- |
500 |
|
- |
| 17.1.1(Gas Consumption) |
- |
500 |
|
- |
| 18(Ignition and Flame Travel) |
- |
500 |
|
- |
| 19(Flame Stability) |
- |
500 |
|
- |
| 20(Noise Control) |
- |
500 |
|
- |
| 21(Flash Back) |
- |
500 |
|
- |
| 22(Formation of Soot) |
- |
500 |
|
- |
| 23(Resistance to Draught) |
- |
500 |
|
- |
| 24(Combustion) |
- |
500 |
|
- |
| 25(Fire Hazard and Limiting Temperature) |
- |
1000 |
|
- |
| 26(Thermal Efficiency) |
- |
3000 |
|
- |
| 27.1(Type Tests) |
- |
1000 |
|
- |
| 27.2(Routine Tests) |
- |
500 |
|
- |
| 29(Marking) |
- |
100 |
|
- |
| 30(Packing) |
- |
100 |
|
- |
| 5.1.2(Toughened glass- Adhesive tape) |
- |
500 |
|
- |
| 5.1.3(Thermal Shock test) |
- |
100 |
|
Single Burner SS Body – Rs. 7,200/- Glass Top – Rs. 9,200/- Double Burner SS Body – Rs. 8,000/- Glass Top – Rs. 10,200/- Three Burner SS Body – Rs. 8,800/- Glass Top – Rs. 11,200/- Four Burner SS Body – Rs. 9,800/- Glass Top - Rs. 12,200/- Five Burner SS |
| 24 (Annex - E)(Combustion (CO and CO2 ratio)) |
- |
100 |
|
- |
| 4.1(Requirement) |
- |
100 |
|
- |
| 5(Materials) |
- |
100 |
|
- |
| 6(Design for Maintenance) |
- |
100 |
|
- |
| 7(Rigidity and Stability) |
- |
100 |
|
- |
| 8(Workmanship and Finish) |
- |
100 |
|
- |
| 9(Gas Taps) |
- |
100 |
|
- |
| 10(Injector Jets) |
- |
100 |
|
- |
| 11(Burners) |
- |
100 |
|
- |
| 12(Burner Pan Supports) |
- |
100 |
|
- |
| 13.1(Gas Soundness) |
- |
100 |
|
- |
| 13.2(Gas Leak Detector) |
- |
100 |
|
- |
| 14(Gas Inlet Connections) |
- |
100 |
|
- |
| 15(Strength and Rigidity) |
- |
100 |
|
- |
| 16(General Conditions of Test) |
- |
100 |
|
- |
| 17.1.1(Gas Consumption) |
- |
100 |
|
- |
| 18(Ignition and Flame Travel) |
- |
100 |
|
- |
| 19(Flame Stability) |
- |
100 |
|
- |
| 20(Noise Control) |
- |
100 |
|
- |
| 21(Flash Back) |
- |
100 |
|
- |
| 22(Formation of Soot) |
- |
100 |
|
- |
| 23(Resistance to Draught) |
- |
100 |
|
- |
| 24(Combustion) |
- |
100 |
|
- |
| 25(Fire Hazard and Limiting Temperature) |
- |
1000 |
|
- |
| 26(Thermal Efficiency) |
- |
3000 |
|
- |
| 27.1(Type Tests) |
- |
1000 |
|
- |
| 27.2(Routine Tests) |
- |
1000 |
|
- |
| 29(Marking) |
- |
500 |
|
- |
| 30(Packing) |
- |
100 |
|
- |
| 5.1.2(Toughened glass- Adhesive tape) |
- |
500 |
|
- |
| 5.1.3(Thermal Shock test) |
- |
500 |
|
- |
| 24 (Annex - E)(Combustion (CO and CO2 ratio)) |
- |
0 |
|
- |
| 4.1(Requirement) |
- |
0 |
|
- |
| 5(Materials) |
- |
0 |
|
- |
| 6(Design for Maintenance) |
- |
0 |
|
- |
| 7(Rigidity and Stability) |
- |
0 |
|
- |
| 8(Workmanship and Finish) |
- |
0 |
|
- |
| 9(Gas Taps) |
- |
0 |
|
- |
| 10(Injector Jets) |
- |
0 |
|
- |
| 11(Burners) |
- |
0 |
|
- |
| 12(Burner Pan Supports) |
- |
0 |
|
- |
| 13.1(Gas Soundness) |
- |
0 |
|
- |
| 13.2(Gas Leak Detector) |
- |
0 |
|
- |
| 14(Gas Inlet Connections) |
- |
0 |
|
- |
| 15(Strength and Rigidity) |
- |
0 |
|
- |
| 16(General Conditions of Test) |
- |
0 |
|
- |
| 17.1.1(Gas Consumption) |
- |
0 |
|
- |
| 18(Ignition and Flame Travel) |
- |
0 |
|
- |
| 19(Flame Stability) |
- |
0 |
|
- |
| 20(Noise Control) |
- |
0 |
|
- |
| 21(Flash Back) |
- |
0 |
|
- |
| 22(Formation of Soot) |
- |
0 |
|
- |
| 23(Resistance to Draught) |
- |
0 |
|
- |
| 24(Combustion) |
- |
0 |
|
- |
| 25(Fire Hazard and Limiting Temperature) |
- |
0 |
|
- |
| 26(Thermal Efficiency) |
- |
0 |
|
- |
| 27.1(Type Tests) |
- |
0 |
|
- |
| 27.2(Routine Tests) |
- |
0 |
|
- |
| 29(Marking) |
- |
0 |
|
- |
| 30(Packing) |
- |
0 |
|
- |
| 5.1.2(Toughened glass- Adhesive tape) |
- |
0 |
|
- |
| 5.1.3(Thermal Shock test) |
- |
0 |
|
- |
|
22 Jul, 2028 |
- Included w.e.f.11.09.2025 |
| 3637 |
Central Institute of Petrochemicals Engineering & Technology (CIPET), Murthal
| 9121934
| IS 14333 (2022) |
Polyethylene Pipes for Sewerage and Industrial Chemicals and Effluent � Specification (First Revision) |
- |
49575 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2.1,T2("Base Density
(At 27°C Temp.)-IS 7328:2020 ") |
- |
1325 |
|
Testing charges = Rs 700/-
Specimen charges = 625 |
| 5.2.1,T2(Melt Flow Rate (At 190°C /5kg)-IS 2530:1963) |
- |
1100 |
|
- |
| 5.2.1,T2(Thermal Stability(Oxidation Induction Time)-IS 4984:2016(Annexure-B)) |
- |
2200 |
|
- |
| 5.2.1,T2("Volatile Matter- IS 4984:2016
(Annexure-C)") |
- |
700 |
|
- |
| 5.2.1,T2("Water Content-IS 4984:2016
(Annexure-D)") |
- |
700 |
|
- |
| 5.2.1.1, T2("Compound carbon black -IS 2530:1963
content") |
- |
925 |
|
- |
| 5.2.1.1, T2("Compound carbon black -IS 2530:1963
dispersion") |
- |
700 |
|
- |
| 5.2.1.1, T2(Compound ash content - Any Method) |
- |
1200 |
|
- |
| 6.2(Colour- IS 14333-2022) |
- |
500 |
|
- |
| 7.1(Visual Appearance- IS 14333-2022) |
- |
500 |
|
- |
| 7.2(Length- IS 14333-2022) |
- |
500 |
|
- |
| 7.4,T3 of IS 4984(Outside Diameter-IS 4984-2016) |
- |
500 |
|
- |
| 7.4,T4 of IS 4984(wall Thickness-IS 4984-2016) |
- |
0 |
|
- |
| 7.4,T3 of IS 4984(Ovality-IS 4984-2016) |
- |
0 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 27 oC , Test Period - 100 hrs.-IS 4984-2016 (Annexure-E)) |
- |
4000 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
1600 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 165 hrs.-IS 4984-2016 (Annexure-E)) |
- |
4800 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 1000 hrs.-IS 4984-2016 (Annexure-E)) |
- |
11000 |
|
- |
| 8.1.2, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
1600 |
|
- |
| 8.2("Longitudinal Reversion Test - IS 4984-2016
(Annexure-F)") |
- |
1200 |
|
Test charges = 700
specimen charges = 500 |
| 8.3(Carbon black content- IS 2530-1963) |
- |
925 |
|
- |
| 8.3(Carbon black content Dispersion- IS 2530-1963) |
- |
700 |
|
- |
| 8.4(Melt Flow rate(Temperature - 190oC,Mass 5kg)-IS 2530-1963) |
- |
1100 |
|
- |
| 8.5(Oxidation Induction Time -IS 4984:2016(Annexure-B)) |
- |
2200 |
|
- |
| 8.6(Density-IS 7328:2020) |
- |
700 |
|
- |
| 8.7("Tensile Strength for Butt Fusion - IS 4984-2016
(Annexure-G)") |
- |
1800 |
|
Test charges = 1300
specimen charges = 500 |
| 8.8,T5("Tensile - IS 4984-2016
(Annexure-H)") |
- |
1800 |
|
Test charges = 1300
specimen charges = 500 |
| 8.8,T5("Elongation -IS 4984-2016
(Annexure-H)") |
- |
1800 |
|
Test charges = 1300
specimen charges = 500 |
| 8.9(Slow Crack Growth Rate{Internal Pressure creep Rupture test, Temperature - 80±1 oC , Test Pressure – 0.80MPa, Test Period - 500 hrs.-IS 4984-2016 (Annexure-E &J)) |
- |
6000 |
|
Test charges = 5500
specimen charges = 500 |
| 5.2.1.1, T2(Compound Density-IS 7328:2020) |
- |
1325 |
|
Test charges = 700
specimen charges = 625 |
| 5.2.1.1, T2(Compound maximum volatile matter -IS 4984:2016 (Annexure-C)) |
- |
700 |
|
- |
| 6(Pipe Description - IS 14333-2022) |
- |
0 |
|
- |
| 5.2.1,T2("Base Density
(At 27°C Temp.)-IS 7328:2020 ") |
- |
1325 |
|
Test charges = 700
specimen charges = 625 |
| 5.2.1,T2(Melt Flow Rate (At 190°C /5kg)-IS 2530:1963) |
- |
1100 |
|
- |
| 5.2.1,T2(Thermal Stability(Oxidation Induction Time)-IS 4984:2016(Annexure-B)) |
- |
2200 |
|
- |
| 5.2.1,T2("Volatile Matter- IS 4984:2016
(Annexure-C)") |
- |
700 |
|
- |
| 5.2.1,T2("Water Content-IS 4984:2016
(Annexure-D)") |
- |
700 |
|
- |
| 5.2.1.1, T2("Compound carbon black -IS 2530:1963
content") |
- |
925 |
|
- |
| 5.2.1.1, T2("Compound carbon black -IS 2530:1963
dispersion") |
- |
700 |
|
- |
| 5.2.1.1, T2(Compound ash content - Any Method) |
- |
1200 |
|
- |
| 6.2(Colour- IS 14333-2022) |
- |
500 |
|
- |
| 7.1(Visual Appearance- IS 14333-2022) |
- |
500 |
|
- |
| 7.2(Length- IS 14333-2022) |
- |
500 |
|
- |
| 7.4,T3 of IS 4984(Outside Diameter-IS 4984-2016) |
- |
500 |
|
- |
| 7.4,T4 of IS 4984(wall Thickness-IS 4984-2016) |
- |
0 |
|
- |
| 7.4,T3 of IS 4984(Ovality-IS 4984-2016) |
- |
0 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 27 oC , Test Period - 100 hrs.-IS 4984-2016 (Annexure-E)) |
- |
4000 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
1600 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 165 hrs.-IS 4984-2016 (Annexure-E)) |
- |
4800 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 1000 hrs.-IS 4984-2016 (Annexure-E)) |
- |
11000 |
|
- |
| 8.1.2, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
1600 |
|
- |
| 8.2("Longitudinal Reversion Test - IS 4984-2016
(Annexure-F)") |
- |
1300 |
|
Test charges = 700
specimen charges = 500 |
| 8.3(Carbon black content- IS 2530-1963) |
- |
925 |
|
- |
| 8.3(Carbon black content Dispersion- IS 2530-1963) |
- |
700 |
|
- |
| 8.4(Melt Flow rate(Temperature - 190oC,Mass 5kg)-IS 2530-1963) |
- |
1100 |
|
- |
| 8.5(Oxidation Induction Time -IS 4984:2016(Annexure-B)) |
- |
2200 |
|
- |
| 8.6(Density-IS 7328:2020) |
- |
1325 |
|
Test charges = 700
specimen charges = 625 |
| 8.7("Tensile Strength for Butt Fusion - IS 4984-2016
(Annexure-G)") |
- |
1800 |
|
Test charges = 1300
specimen charges = 500 |
| 8.8,T5("Tensile - IS 4984-2016
(Annexure-H)") |
- |
1800 |
|
Test charges = 1300
specimen charges = 500 |
| 8.8,T5("Elongation -IS 4984-2016
(Annexure-H)") |
- |
1800 |
|
Test charges = 1300
specimen charges = 500 |
| 8.9(Slow Crack Growth Rate{Internal Pressure creep Rupture test, Temperature - 80±1 oC , Test Pressure – 0.80MPa, Test Period - 500 hrs.-IS 4984-2016 (Annexure-E &J)) |
- |
6000 |
|
Test charges = 5500
specimen charges = 500 |
| 5.2.1.1, T2(Compound Density-IS 7328:2020) |
- |
1325 |
|
Test charges = 700
specimen charges = 625 |
| 5.2.1.1, T2(Compound maximum volatile matter -IS 4984:2016 (Annexure-C)) |
- |
700 |
|
- |
| 6(Pipe Description - IS 14333-2022) |
- |
0 |
|
- |
| 5.2.1,T2("Base Density
(At 27°C Temp.)-IS 7328:2020 ") |
- |
1325 |
|
Test charges = 700
specimen charges = 625 |
| 5.2.1,T2(Melt Flow Rate (At 190°C /5kg)-IS 2530:1963) |
- |
1100 |
|
- |
| 5.2.1,T2(Thermal Stability(Oxidation Induction Time)-IS 4984:2016(Annexure-B)) |
- |
2200 |
|
- |
| 5.2.1,T2("Volatile Matter- IS 4984:2016
(Annexure-C)") |
- |
700 |
|
- |
| 5.2.1,T2("Water Content-IS 4984:2016
(Annexure-D)") |
- |
700 |
|
- |
| 5.2.1.1, T2("Compound carbon black -IS 2530:1963
content") |
- |
925 |
|
- |
| 5.2.1.1, T2("Compound carbon black -IS 2530:1963
dispersion") |
- |
700 |
|
- |
| 5.2.1.1, T2(Compound ash content - Any Method) |
- |
1200 |
|
- |
| 6.2(Colour- IS 14333-2022) |
- |
500 |
|
- |
| 7.1(Visual Appearance- IS 14333-2022) |
- |
500 |
|
- |
| 7.2(Length- IS 14333-2022) |
- |
500 |
|
- |
| 7.4,T3 of IS 4984(Outside Diameter-IS 4984-2016) |
- |
500 |
|
- |
| 7.4,T4 of IS 4984(wall Thickness-IS 4984-2016) |
- |
0 |
|
- |
| 7.4,T3 of IS 4984(Ovality-IS 4984-2016) |
- |
0 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 27 oC , Test Period - 100 hrs.-IS 4984-2016 (Annexure-E)) |
- |
4000 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
1600 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 165 hrs.-IS 4984-2016 (Annexure-E)) |
- |
4800 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 1000 hrs.-IS 4984-2016 (Annexure-E)) |
- |
11000 |
|
- |
| 8.1.2, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
1600 |
|
- |
| 8.2("Longitudinal Reversion Test - IS 4984-2016
(Annexure-F)") |
- |
1200 |
|
Test charges = 700
specimen charges = 500 |
| 8.3(Carbon black content- IS 2530-1963) |
- |
925 |
|
- |
| 8.3(Carbon black content Dispersion- IS 2530-1963) |
- |
700 |
|
- |
| 8.4(Melt Flow rate(Temperature - 190oC,Mass 5kg)-IS 2530-1963) |
- |
1100 |
|
- |
| 8.5(Oxidation Induction Time -IS 4984:2016(Annexure-B)) |
- |
2200 |
|
- |
| 8.6(Density-IS 7328:2020) |
- |
700 |
|
- |
| 8.7("Tensile Strength for Butt Fusion - IS 4984-2016
(Annexure-G)") |
- |
1800 |
|
Test charges = 1300
specimen charges = 500 |
| 8.8,T5("Tensile - IS 4984-2016
(Annexure-H)") |
- |
1800 |
|
Test charges = 1300
specimen charges = 500 |
| 8.8,T5("Elongation -IS 4984-2016
(Annexure-H)") |
- |
1800 |
|
Test charges = 1300
specimen charges = 500 |
| 8.9(Slow Crack Growth Rate{Internal Pressure creep Rupture test, Temperature - 80±1 oC , Test Pressure – 0.80MPa, Test Period - 500 hrs.-IS 4984-2016 (Annexure-E &J)) |
- |
6000 |
|
Test charges = 5500
specimen charges = 500 |
| 5.2.1.1, T2(Compound Density-IS 7328:2020) |
- |
1325 |
|
Test charges = 700
specimen charges = 625 |
| 5.2.1.1, T2(Compound maximum volatile matter -IS 4984:2016 (Annexure-C)) |
- |
700 |
|
- |
| 6(Pipe Description - IS 14333-2022) |
- |
0 |
|
- |
|
09 Aug, 2028 |
- Included w.e.f.05.08.2025
Exclusion
Cl 5.2.1.1, T2
Cl 5.3
Cl 5.4((Antioxidant
Cl 7.3 (Coiling |
| 3638 |
EMC Testing and Compliance LLP, Gurugram
| 8141526
| IS 17631 (2022) |
Work Chairs - Specification |
- |
70000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| clause 4(DESIGN AND WORKMANSHIP) |
- |
4000 |
|
- |
| clause 5(DIMENSIONS) |
- |
2000 |
|
- |
| Cl-6.1 (a)(Resistance to mechanical damage) |
- |
2000 |
|
- |
| Cl-6.2 (a) (1)(For Fabric and Synthetic Leather:- Breaking load) |
- |
2000 |
|
- |
| Cl-7.3.1(Front Edge Overturning) |
- |
5000 |
|
- |
| Cl-7.3.2(Forwards Overturning) |
- |
4500 |
|
- |
| Cl-7.3.3(Forwards Overturning for Chairs with Foot Rest) |
- |
5000 |
|
- |
| Cl-7.3.4(Sideways Overturning for Chairs Without Arm Rests) |
- |
7500 |
|
- |
| Cl-6.1 (b)(Pencil hardness) |
- |
1000 |
|
- |
| Cl-6.1 (c)(Resistance to wet heat;) |
- |
1000 |
|
- |
| Cl-6.1 (d)(Resistance to dry heat;) |
- |
1500 |
|
- |
| Cl-6.1 (e)(Resistance to marking by cold liquids) |
- |
1500 |
|
- |
| Cl-6.1 (f)(Resistance to marking by cold oils and fats;) |
- |
1500 |
|
- |
| Cl-6.1 (g)(Adhesive performance) |
- |
1000 |
|
- |
| Cl-6.2 (a) (2)(For Fabric and Synthetic Leather:- Elongation at break) |
- |
1000 |
|
- |
| Cl-6.2 (a) (3)(For Fabric and Synthetic Leather:- Tear strength) |
- |
1000 |
|
- |
| Cl-6.2 (a) (4)(For Fabric and Synthetic Leather:- Colour fastness to light) |
- |
1500 |
|
- |
| Cl-6.2 (a) (5)(For Fabric and Synthetic Leather:- Colour fastness to rubbing) |
- |
1500 |
|
- |
| Cl-6.2 (a) (6)(For Fabric and Synthetic Leather:- Colour fastness to perspiration) |
- |
2000 |
|
- |
| Cl-6.2 (a) (7)(For Fabric and Synthetic Leather:- Colour fastness to water) |
- |
2000 |
|
- |
| Cl-6.2 (a) (8)(For Fabric and Synthetic Leather:- Pilling resistance) |
- |
1000 |
|
- |
| Cl-6.2 (a) (9)(For Fabric and Synthetic Leather:- Coating adhesion strength) |
- |
1000 |
|
- |
| Cl-6.2 (a) (10)(For Fabric and Synthetic Leather:- Seam slippage) |
- |
1000 |
|
- |
| Cl-6.2 (a) (11)(For Fabric and Synthetic Leather:- Resistance to damage by flexing) |
- |
1000 |
|
- |
| Cl-6.2 (a) (12)(For Fabric and Synthetic Leather:- Abrasion resistance) |
- |
1500 |
|
- |
| Cl-6.2 (a) (13)(For Fabric and Synthetic Leather:- Bursting strength) |
- |
1000 |
|
- |
| Cl-6.2 (a) (14)(For Fabric and Synthetic Leather:- Resistance to cold) |
- |
1000 |
|
- |
| Cl-6.2 (b) (2)(For Natural Leather:- Flexing endurance) |
- |
1500 |
|
- |
| Cl-6.2 (b) (1)(For Natural Leather:- Tear strength) |
- |
1000 |
|
- |
| Cl-6.2 (b) (3)(For Natural Leather: Finish adhesion) |
- |
1000 |
|
- |
| Cl-6.2 (b) (4)(For Natural Leather: Colour fastness to artificial light) |
- |
1500 |
|
- |
| Cl-6.2 (b) (5)(For Natural Leather: Colour fastness to rubbing) |
- |
1000 |
|
- |
| Cl-6.2 (b) (6)(For Natural Leather: Colour fastness to water spotting) |
- |
1500 |
|
- |
| Cl-6.2 (b) (7)(For Natural Leather: Water vapour permeability) |
- |
1000 |
|
- |
| Cl-6.2 (b) (8)(For Natural Leather: Colour fastness to water) |
- |
1000 |
|
- |
| Cl-7.3.5(Sideways Overturning for Chairs With Arm Rests) |
- |
4000 |
|
- |
| Cl-7.3.6(Rearwards Overturning for Chairs Without Back Rest Inclination) |
- |
1500 |
|
- |
| Cl-7.3.7(Rearwards Overturning for Chairs with Backrest Inclination) |
- |
1500 |
|
- |
| Cl-7.4.1(Seat Front Edge Static Load Test) |
- |
1500 |
|
- |
| Cl-7.4.2(Combined Seat and Back Static Load Test) |
- |
2000 |
|
- |
| Cl-7.4.3(Arm Rest Downward Static Load Test — Central) |
- |
2000 |
|
- |
| Cl-7.4.4(Arm Rest Downward Static Load Test — Front) |
- |
1500 |
|
- |
| Cl-7.4.5(Arm Rest Sideways Static Load Test) |
- |
2000 |
|
- |
| Cl-7.4.6(Foot Rest Static Load Test) |
- |
2000 |
|
- |
| Cl-7.5.1(Seat and Back Durability) |
- |
19000 |
|
- |
| Cl-7.5.2(Arm Rest Durability) |
- |
18000 |
|
- |
| Cl-7.5.3(Swivel Test) |
- |
16000 |
|
- |
| Cl-7.5.4(Foot-rest Durability) |
- |
13000 |
|
- |
| Cl-7.5.5(Castor and Chair-Base Durability) |
- |
16000 |
|
- |
|
19 Jul, 2027 |
- Included w.e.f 08.09.2025 |
| 3639 |
CIPET. MYSURU
| 6113734
| IS 13487 (2024) |
Irrigation Equipment — Emitters — Specification |
SIZE |
6150 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-7.1(Construction and Workmanship) |
- |
225 |
|
- |
| Cl-7.2(Flow Paths in Emitter) |
- |
225 |
|
- |
| Cl-7.3(Resistance to Hydrostatic Pressure) |
- |
750 |
|
- |
| Cl-7.4(Emitter Pull-Out) |
- |
750 |
|
- |
| Cl-7.4.1(In-Line Emitters) |
- |
750 |
|
- |
| Cl-7.4.2(On-Line Emitters) |
- |
750 |
|
- |
| Cl-8.1.1(Uniformity of Emission Rate) |
- |
750 |
|
- |
| Cl-5.1(Connections) |
- |
0 |
|
- |
| Cl-5.2(Emitter Ends) |
- |
0 |
|
- |
| Cl-5.3(Materials) |
- |
0 |
|
- |
| Cl-6.1(Test Specimens) |
- |
0 |
|
- |
| Cl-6.2.1(polyethylene pipe) |
- |
0 |
|
- |
| Cl-6.2.2("grease or chemicals
") |
- |
0 |
|
- |
| Cl-6.2.3(water temperature) |
- |
0 |
|
- |
| Cl-6.3(Accuracy or Measuring Devices) |
- |
0 |
|
- |
| Cl-8.1.2(Emission Rate as Function of Inlet Pressure) |
- |
749.98 |
|
- |
| Cl-8.1.3(Determination of Emitter Exponent) |
- |
450 |
|
- |
| Cl-9(Marking) |
- |
500 |
|
- |
| Cl-7.1(Construction and Workmanship) |
- |
225 |
|
- |
| Cl-7.2(Flow Paths in Emitter) |
- |
225 |
|
- |
| Cl-7.3(Resistance to Hydrostatic Pressure) |
- |
750 |
|
- |
| Cl-7.4(Emitter Pull-Out) |
- |
750 |
|
- |
| Cl-7.4.1(In-Line Emitters) |
- |
750 |
|
- |
| Cl-7.4.2(On-Line Emitters) |
- |
750 |
|
- |
| Cl-8.1.1(Uniformity of Emission Rate) |
- |
750 |
|
- |
| Cl-5.1(Connections) |
- |
0 |
|
- |
| Cl-5.2(Emitter Ends) |
- |
0 |
|
- |
| Cl-5.3(Materials) |
- |
0 |
|
- |
| Cl-6.1(Test Specimens) |
- |
0 |
|
- |
| Cl-6.2.1(polyethylene pipe) |
- |
0 |
|
- |
| Cl-6.2.2("grease or chemicals
") |
- |
0 |
|
- |
| Cl-6.2.3(water temperature) |
- |
0 |
|
- |
| Cl-6.3(Accuracy or Measuring Devices) |
- |
0 |
|
- |
| Cl-8.1.2(Emission Rate as Function of Inlet Pressure) |
- |
750 |
|
- |
| Cl-8.1.3(Determination of Emitter Exponent) |
- |
750 |
|
- |
| Cl-9(Marking) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- iNCLUDED W.E.F.01.08.2025 |
| 3640 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/41), GHAZIABAD
| 9179706
| IS 11226 (1993) |
Leather safety footwear having direct moulded rubber sole specification (First Revision) |
ALL |
21000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(REQUIREMENTS) |
- |
500 |
|
- |
| 5.2(Materials) |
- |
500 |
|
- |
| 5.2.1(Materials) |
- |
500 |
|
- |
| 5.2.1.1(Materials) |
- |
500 |
|
- |
| 5.2.2(Materials) |
- |
500 |
|
- |
| 5.2.3(Materials) |
- |
500 |
|
- |
| 5.2.4(Materials) |
- |
500 |
|
- |
| 5.2.5(Materials) |
- |
500 |
|
- |
| 5.2.6(Materials) |
- |
500 |
|
- |
| 5.2.6.1(Materials) |
- |
500 |
|
- |
| 5.2.6.2(Materials) |
- |
500 |
|
- |
| 5.2.6.3(Materials) |
- |
500 |
|
- |
| 5.2.7(Materials) |
- |
500 |
|
- |
| 5.2.8(Materials) |
- |
500 |
|
- |
| 5.2.9(Materials) |
- |
500 |
|
- |
| 5.2.10(Materials) |
- |
500 |
|
- |
| 5.2.11(Materials) |
- |
500 |
|
- |
| 5.2.11.1(Materials) |
- |
500 |
|
- |
| 5.2.11.2(Materials) |
- |
500 |
|
- |
| 5.2.11.3(Materials) |
- |
500 |
|
- |
| 5.3(Components) |
- |
700 |
|
- |
| 5.4( Manufacture ) |
- |
400 |
|
- |
| 5.4.1( Manufacture ) |
- |
400 |
|
- |
| 5.4.8(Workmanship and Finish) |
- |
300 |
|
- |
| 5.5(Mass) |
- |
300 |
|
- |
| 5.6(Performance Test) |
- |
1000 |
|
- |
| 5.7(Adhesion Test on Moulded Bottoms) |
- |
1000 |
|
- |
| 7(MARKING) |
- |
300 |
|
- |
| 5.7(Toe adhesion ) |
- |
1000 |
|
- |
| 5.6.(Toe Impact test) |
- |
1000 |
|
- |
| 5.5(Mass per pairs) |
- |
400 |
|
- |
| 5.4.8(Leg height) |
- |
300 |
|
- |
| 5.4(Dimension ) |
- |
500 |
|
- |
| 5.3 & 5.4.2(Thickness of components ) |
- |
400 |
|
- |
| 5.2.11.2(Flexing resistance) |
- |
1000 |
|
- |
| 5.2.11.2(Resistance to Fuel Oil) |
- |
1000 |
|
- |
| 5.2.11.2(Elongation at break) |
- |
1000 |
|
- |
| 5.2.11.2(Tensile Strength) |
- |
1000 |
|
- |
| 5.2.11.2(Hardness (Shore A)) |
- |
500 |
|
- |
| 5.2.11(Hardness (IRHD)-after ageing) |
- |
700 |
|
- |
| 5.2.11(Flexing resistance) |
- |
1000 |
|
- |
| 5.2.11(Elongation at break) |
- |
1000 |
|
- |
| 5.2.11(Tensile Strength) |
- |
1000 |
|
- |
| 5.2.11(Hardness (IRHD)) |
- |
500 |
|
- |
| 5.2.11(Relative density ) |
- |
1000 |
|
- |
| 5.1(REQUIREMENTS) |
- |
0 |
|
- |
| 5.2(Materials) |
- |
0 |
|
- |
| 5.2.1(Materials) |
- |
0 |
|
- |
| 5.2.1.1(Materials) |
- |
0 |
|
- |
| 5.2.2(Materials) |
- |
0 |
|
- |
| 5.2.3(Materials) |
- |
0 |
|
- |
| 5.2.4(Materials) |
- |
0 |
|
- |
| 5.2.5(Materials) |
- |
0 |
|
- |
| 5.2.6(Materials) |
- |
0 |
|
- |
| 5.2.6.1(Materials) |
- |
0 |
|
- |
| 5.2.6.2(Materials) |
- |
0 |
|
- |
| 5.2.6.3(Materials) |
- |
0 |
|
- |
| 5.2.7(Materials) |
- |
0 |
|
- |
| 5.2.8(Materials) |
- |
0 |
|
- |
| 5.2.9(Materials) |
- |
0 |
|
- |
| 5.2.10(Materials) |
- |
0 |
|
- |
| 5.2.11(Materials) |
- |
0 |
|
- |
| 5.2.11.1(Materials) |
- |
0 |
|
- |
| 5.2.11.2(Materials) |
- |
0 |
|
- |
| 5.2.11.3(Materials) |
- |
0 |
|
- |
| 5.3(Components) |
- |
0 |
|
- |
| 5.4( Manufacture ) |
- |
0 |
|
- |
| 5.4.1( Manufacture ) |
- |
0 |
|
- |
| 5.4.8(Workmanship and Finish) |
- |
0 |
|
- |
| 5.5(Mass) |
- |
0 |
|
- |
| 5.6(Performance Test) |
- |
0 |
|
- |
| 5.7(Adhesion Test on Moulded Bottoms) |
- |
0 |
|
- |
| 7(MARKING) |
- |
0 |
|
- |
| 5.7(Toe adhesion ) |
- |
0 |
|
- |
| 5.6.(Toe Impact test) |
- |
0 |
|
- |
| 5.5(Mass per pairs) |
- |
0 |
|
- |
| 5.4.8(Leg height) |
- |
0 |
|
- |
| 5.4(Dimension ) |
- |
0 |
|
- |
| 5.3 & 5.4.2(Thickness of components ) |
- |
0 |
|
- |
| 5.2.11.2(Flexing resistance) |
- |
0 |
|
- |
| 5.2.11.2(Resistance to Fuel Oil) |
- |
0 |
|
- |
| 5.2.11.2(Elongation at break) |
- |
0 |
|
- |
| 5.2.11.2(Tensile Strength) |
- |
0 |
|
- |
| 5.2.11.2(Hardness (Shore A)) |
- |
0 |
|
- |
| 5.2.11(Hardness (IRHD)-after ageing) |
- |
0 |
|
- |
| 5.2.11(Flexing resistance) |
- |
0 |
|
- |
| 5.2.11(Elongation at break) |
- |
0 |
|
- |
| 5.2.11(Tensile Strength) |
- |
0 |
|
- |
| 5.2.11(Hardness (IRHD)) |
- |
0 |
|
- |
| 5.2.11(Relative density ) |
- |
0 |
|
- |
|
- |
- Included w.e.f 08.12.2025 |
| 3641 |
Bombay Textiles Research Association (BTRA), Mumbai
| 7130206
| IS 15041 (2001) |
Textiles – Flat woven webbing slings made of man-made fibres for general services |
Textile |
26230 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1(REQUIREMENTS :-Webbing) |
- |
2510 |
|
- |
| 4.1.2.1(Weaving) |
- |
500 |
|
- |
| 4.1.2.2(Weaving) |
- |
500 |
|
- |
| 4.1.3(Width) |
- |
500 |
|
- |
| 4.1.4(Thickness) |
- |
1000 |
|
- |
| 4.1.5( Dyeing) |
- |
4500 |
|
- |
| 4.1.6(Other Treatments, Afiertreatments or Coverings) |
- |
0 |
|
Already given in cl no. 4.1.5 |
| 4.2.1(Sewing of Slings) |
- |
1720 |
|
Sewing (Yarn) Thread Strength |
| 4.2.2(Sewing of Slings) |
- |
0 |
|
Test facility not available |
| 4.2.3(Sewing of Slings) |
- |
500 |
|
- |
| 4.2.3.1(Sewing of Slings) |
- |
500 |
|
- |
| 4.2.4 (Sewing of Slings) |
- |
500 |
|
- |
| 4.2.4.1(Sewing of Slings) |
- |
1000 |
|
- |
| 4.2.5(Sewing of Slings) |
- |
500 |
|
- |
| 4.2.5.1(Sewing of Slings) |
- |
500 |
|
- |
| 4.3.1,Fig. 10(Soft Eyes) |
- |
500 |
|
- |
| 4.3.2(Soft Eyes) |
- |
500 |
|
- |
| 4.4.1(End Fittings :General) |
- |
500 |
|
- |
| 4.4.3 (End Fittings :-Finish) |
- |
500 |
|
- |
| 4.4.4 (End Fittings :-Form) |
- |
1000 |
|
- |
| 4.4.5 & 5.4(End Fittings :-Proof Testing) |
- |
1000 |
|
- |
| 4.5 & 5.2(Working Load Limit) |
- |
3500 |
|
- |
| 4.6 & A-2(Maximum Safe Working Load) |
- |
0 |
|
Already given in cl no. 4.5 & 5.2 |
| 4.2.1(Sewing of Slings) |
- |
4000 |
|
Tensile Strength Webbing & Seam |
| 4.1.1(REQUIREMENTS :-Webbing) |
- |
0 |
|
Already given |
| 4.1.2.1(Weaving) |
- |
0 |
|
Already given |
| 4.1.2.2(Weaving) |
- |
0 |
|
Already given |
| 4.1.3(Width) |
- |
0 |
|
Already given |
| 4.1.4(Thickness) |
- |
0 |
|
Already given |
| 4.1.5( Dyeing) |
- |
0 |
|
Already given |
| 4.1.6(Other Treatments, Afiertreatments or Coverings) |
- |
0 |
|
Already given |
| 4.2.2(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.3(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.3.1(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.4 (Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.4.1(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.5(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.5.1(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.3.1,Fig. 10(Soft Eyes) |
- |
0 |
|
Already given |
| 4.3.2(Soft Eyes) |
- |
0 |
|
Already given |
| 4.4.1(End Fittings :General) |
- |
0 |
|
Already given |
| 4.4.3 (End Fittings :-Finish) |
- |
0 |
|
Already given |
| 4.4.4 (End Fittings :-Form) |
- |
0 |
|
Already given |
| 4.4.5 & 5.4(End Fittings :-Proof Testing) |
- |
0 |
|
Already given |
| 4.5 & 5.2(Working Load Limit) |
- |
0 |
|
Already given |
| 4.6 & A-2(Maximum Safe Working Load) |
- |
0 |
|
Already given |
| 4.1.1(REQUIREMENTS :-Webbing) |
- |
0 |
|
Already given |
| 4.1.2.1(Weaving) |
- |
0 |
|
Already given |
| 4.1.2.2(Weaving) |
- |
0 |
|
Already given |
| 4.1.3(Width) |
- |
0 |
|
Already given |
| 4.1.4(Thickness) |
- |
0 |
|
Already given |
| 4.1.5( Dyeing) |
- |
0 |
|
Already given |
| 4.1.6(Other Treatments, Afiertreatments or Coverings) |
- |
0 |
|
Already given |
| 4.2.1(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.2(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.3(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.3.1(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.4 (Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.4.1(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.5(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.5.1(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.3.1,Fig. 10(Soft Eyes) |
- |
0 |
|
Already given |
| 4.3.2(Soft Eyes) |
- |
0 |
|
Already given |
| 4.4.1(End Fittings :General) |
- |
0 |
|
Already given |
| 4.4.3 (End Fittings :-Finish) |
- |
0 |
|
Already given |
| 4.4.4 (End Fittings :-Form) |
- |
0 |
|
Already given |
| 4.4.5 & 5.4(End Fittings :-Proof Testing) |
- |
0 |
|
Already given |
| 4.5 & 5.2(Working Load Limit) |
- |
0 |
|
Already given |
| 4.6 & A-2(Maximum Safe Working Load) |
- |
0 |
|
Already given |
| 4.1.1(REQUIREMENTS :-Webbing) |
- |
0 |
|
Already given |
| 4.1.2.1(Weaving) |
- |
0 |
|
Already given |
| 4.1.2.2(Weaving) |
- |
0 |
|
Already given |
| 4.1.3(Width) |
- |
0 |
|
Already given |
| 4.1.4(Thickness) |
- |
0 |
|
Already given |
| 4.1.5( Dyeing) |
- |
0 |
|
Already given |
| 4.1.6(Other Treatments, Afiertreatments or Coverings) |
- |
0 |
|
Already given |
| 4.2.1(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.2(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.3(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.3.1(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.4 (Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.4.1(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.5(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.2.5.1(Sewing of Slings) |
- |
0 |
|
Already given |
| 4.3.1,Fig. 10(Soft Eyes) |
- |
0 |
|
Already given |
| 4.3.2(Soft Eyes) |
- |
0 |
|
Already given |
| 4.4.1(End Fittings :General) |
- |
0 |
|
Already given |
| 4.4.3 (End Fittings :-Finish) |
- |
0 |
|
Already given |
| 4.4.4 (End Fittings :-Form) |
- |
0 |
|
Already given |
| 4.4.5 & 5.4(End Fittings :-Proof Testing) |
- |
0 |
|
Already given |
| 4.5 & 5.2(Working Load Limit) |
- |
0 |
|
Already given |
| 4.6 & A-2(Maximum Safe Working Load) |
- |
0 |
|
Already given |
|
- |
- Included w.e.f 04.08.2025 |
| 3642 |
Br. MSME- DEVELOPMENT INSTITUTE, COIMBATORE
| 6105534
| IS 12225 (2025) |
CENTRIFUGAL JET PUMP SPECIFICATION (second revision) |
Upto 2.2kW |
17700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-6.1(Other General Requirements) |
- |
17700 |
|
For Complete IS; Upto 2.2kW |
| Cl-6.2(Hydrostatic Test) |
- |
17700 |
|
For Complete IS; Upto 2.2kW |
| Cl-6.3(Cables used) |
- |
17700 |
|
For Complete IS; Upto 2.2kW |
| Cl-6.4(Voltage and Frequency Variation) |
- |
17700 |
|
For Complete IS; Upto 2.2kW |
| Cl-8(Centrifugal jet pump) |
- |
17700 |
|
For Complete IS; Upto 2.2kW |
| Cl-9.1(Factor Affecting Performance) |
- |
17700 |
|
For Complete IS; Upto 2.2kW |
| Cl-9.2(Performance Curves) |
- |
17700 |
|
For Complete IS; Upto 2.2kW |
| Cl-10.1(Method of Testing) |
- |
17700 |
|
For Complete IS; Upto 2.2kW |
| Cl-10.2(Testing Method for Centrifugal Jet Pump for Including Pipe Friction by the Use of Orifice Plate) |
- |
17700 |
|
For Complete IS; Upto 2.2kW |
| Cl-11(TOLERANCES) |
- |
17700 |
|
For Complete IS; Upto 2.2kW |
| Cl-13(Marking) |
- |
17700 |
|
For Complete IS; Upto 2.2kW |
| Cl-6.1(Other General Requirements) |
- |
17700 |
|
- |
| Cl-6.2(Hydrostatic Test) |
- |
17700 |
|
- |
| Cl-6.3(Cables used) |
- |
17700 |
|
- |
| Cl-6.4(Voltage and Frequency Variation) |
- |
17700 |
|
- |
| Cl-8(Centrifugal jet pump) |
- |
17700 |
|
- |
| Cl-9.1(Factor Affecting Performance) |
- |
17700 |
|
- |
| Cl-9.2(Performance Curves) |
- |
17700 |
|
- |
| Cl-10.1(Method of Testing) |
- |
17700 |
|
- |
| Cl-10.2(Testing Method for Centrifugal Jet Pump for Including Pipe Friction by the Use of Orifice Plate) |
- |
17700 |
|
- |
| Cl-11(TOLERANCES) |
- |
17700 |
|
- |
| Cl-13(Marking) |
- |
17700 |
|
- |
|
14 Jan, 2028 |
- "1 Cl-6.1 (Other General Requirements) 5.2.2 Engine Drive The lab does not have facilities to check the engine as per IS 7347 or IS 10001 or IS 11170. Engine Driven Centrifugal Jet Pumps as per IS 12225 may be exclued.
2 Cl-6.1 (Other General Requirements) 5.2.3 Coupled and Belt Driven Set The lab does not have facilities to check the coupled & belt driven sets. Coupled and Belt Driven Centrifugal Jet Pumps as per IS 12225 may be exclued." |
| 3643 |
Atmy Analytical Labs Pvt. Ltd., Faridabad
| 8167506
| IS 2556 : Part 2 (2024) |
Vitreous China Sanitary Appliances âSpecification Part 2 Specific Requirements of Washdown Water Closets (Sixth Revision) |
- |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-3(GENERAL REQUIREMENTS) |
- |
500 |
|
- |
| Cl-4(PATTERNS) |
- |
500 |
|
- |
| Cl-7(FINISH) |
- |
500 |
|
- |
| Cl-5(DIMENSIONS AND TOLERANCES) |
- |
1000 |
|
- |
| Cl-6(CONSTRUCTIONS) |
- |
1000 |
|
- |
| Cl-8.1(Toilet Paper Test) |
- |
1500 |
|
- |
| Cl-8.2(Smudge Test) |
- |
1500 |
|
- |
| Cl-8.3(Holding Capacity Test) |
- |
1500 |
|
- |
| Cl-8.4.1(Single Ball Test) |
- |
2500 |
|
Cl. 8.4.1 + Cl. 8.4.2 - Total 2500 Rs/- |
| Cl-8.4.2(Fifty Ball Test) |
- |
2500 |
|
Cl. 8.4.1 + Cl. 8.4.2 - Total 2500 Rs/- |
| Cl-8.5(Load Bearing Test) |
- |
2500 |
|
- |
| Cl-8.6(Saw Dust Test) |
- |
1500 |
|
- |
| Cl-8.7(Splash Test) |
- |
1500 |
|
- |
| Cl-10("ADDITIONAL REQUIREMENTS FOR
WATER EFFICIENCY") |
- |
1000 |
|
- |
| Cl-11(Marking) |
- |
500 |
|
- |
| As per Clause 3(General requirements: - Material and manufacture IS 2556 (Part 1)) |
- |
1000 |
|
- |
| As per Clause 3(General requirements: - Application of Glazing IS 2556 (Part 1)) |
- |
1000 |
|
- |
| As per Clause 3(General requirements: -Permissible blemishes or defects (WC pans, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-General-Wavy finish as per IS 2556 (Part 1)) |
- |
1000 |
|
- |
| As per Clause 3(General requirements-Permissible blemishes or defects (WC pans, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-General-Warpage as per IS 2556 (Part 1)) |
- |
1000 |
|
- |
| As per Clause 3(General requirements-Permissible blemishes or defects (WC pans, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-General-Bit as per IS 2556 (Part 1)) |
- |
1000 |
|
- |
| As per Clause 3(General requirements-Permissible blemishes or defects (WC pans, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-General-Discoloration as per IS 2556 (Part 1)) |
- |
0 |
|
- |
| As per Clause 3(General requirements-Permissible blemishes or defects (WC pans, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-Flushing surface and horizontal face of rims of WC pans, Squatting pans bidets and urinals-Spots, blisters and pinholes as per IS 2556 (Part 1)) |
- |
0 |
|
- |
| As per Clause 3(General requirements-Permissible blemishes or defects (WC pans, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-Flushing surface and horizontal face of rims of WC pans, Squatting pans bidets and urinals-bubbles and specks as per IS 2556 (Part 1)) |
- |
0 |
|
- |
| As per Clause 3(General requirements-Permissible blemishes or defects (WC pans, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-Flushing surface and horizontal face of rims of WC pans, Squatting pans bidets and urinals-polishing marks as per IS 2556 (Part 1)) |
- |
0 |
|
- |
| As per Clause 3(General requirements-Permissible blemishes or defects (WC apns, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-Visible surfaces other than above-Spots, blisters and pinholes as per 2556 (Part 1)) |
- |
0 |
|
- |
| As per Clause 3(General requirements-Permissible blemishes or defects (WC apns, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-Visible surfaces other than above-Bubbles and specks as per IS 2556 (Part 1)) |
- |
0 |
|
- |
| As per Clause 3(General requirements-Permissible blemishes or defects (WC apns, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-Visible surfaces other than above-Polishing Marks as per IS 2556 (Part 1)) |
- |
0 |
|
- |
| As per Clause 3(General requirements - Minimum Thickness as per IS 2556 (Part 1)) |
- |
1000 |
|
- |
| As per Clause 3(General requirements - Warpage as per IS 2556 (Part 1)) |
- |
1000 |
|
- |
| As per Clause 3(General requirements - Crazing as per IS 2556 (Part 1)) |
- |
1000 |
|
- |
| As per Clause 3(General requirements - Water Absorption as per IS 2556 (Part 1)) |
- |
1000 |
|
- |
| As per Clause 3(General requirements - Modulus of Rupture as per IS 2556 (Part 1)) |
- |
1500 |
|
- |
| As per Clause 3(General requirements - Chemical Resistance Test as per IS 2556 (Part 1)) |
- |
1500 |
|
- |
| As per Clause 3(General requirements - Resistance to Staining and Burning as per IS 2556 (Part 1)) |
- |
1500 |
|
- |
| As per Clause 4(Patterns) |
- |
0 |
|
- |
| As per Clause 5 - Table 1 - i)(Height - A) |
- |
500 |
|
- |
| As per Clause 5 - Table 1 - ii)(Depth of water seal, Min - H) |
- |
1000 |
|
- |
| As per Clause 5 - Table 1 - iii)(Width of water closet - J) |
- |
1000 |
|
- |
| As per Clause 5 - Table 1 - iv)(Distance from centre of seat bolt hole to front of water closet - K) |
- |
1000 |
|
- |
| As per Clause 5 - Table 1 - v)(Distance from centre of seat bolt
hole to inside face of flush rim at
back, Max - L) |
- |
1000 |
|
- |
| As per Clause 5 - Table 1 - vi)(Distance between a vertical line
from tip of back plate to inside
face of flush rim at back, Max - O) |
- |
1000 |
|
- |
| As per Clause 5 - Table 1 - vii)(Width of opening, Min - P) |
- |
1000 |
|
- |
| As per Clause 5 - Table 1 - viii)(Length of opening, Min - Q) |
- |
1000 |
|
- |
| As per Clause 5 - Table 1 - ix)(Overall length - S) |
- |
1000 |
|
- |
| As per Clause 5 - Table 1 - x)(Trap inlet depth, Min - T) |
- |
1000 |
|
- |
| As per Clause 5 - Table 1 - xi)(Water surface
Back to front - W1) |
- |
1000 |
|
- |
| As per Clause 5 - Table 1 - xi)(Water surface
Side to side - W2) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - i)(Height of centre line of flush inlet floor
level, (for P-trap only) - B) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - ii)(Height of centre line of outlet from floor
level, (for P-trap only) - C1) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - iii)(Distance from end of trap to floor (for
S-trap only) - C2) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - iv)(Internal diameter of outlet, Min - D) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - v)(External diameter of outlet - D1) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - vi)(Radius of free space (to be measured
from the centre of the outlet, taken at a
distance 40 mm from the end of the
outlet), Min - D2/2) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - vii)(Internal diameter of inlet - E2) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - viii)(Depth of inlet F socket, Min - F) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - ix)(Distance between end of flush inlet
socket and outside of the outlet - G) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - ix)(Distance between end of flush inlet
socket and outside of the outlet - G1) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - x)(Distance between end of flush inlet
socket and centre line of the outlet- G2) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - x)(Distance between end of flush inlet
socket and centre line of the outlet - G3) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - xi)(Diameter of seat bolt hole - M) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - xii)(Distance between centre of seat bolt
holes - N) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - xiii)(Length of grooved part of outlet, Min - R) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - xiv)(Length of straight part of outlet glazed
and without groove - R1) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - xv)(Angle of outlet (for P-trap only) - ∅) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - xvi)(Distance between end of outlet and floor - X) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - xvii)(Length of outlet without grooves- Y) |
- |
1000 |
|
- |
| As per Clause 5 and 6 - Table 2 - xviii)(Length of outlet extending to the floor - Y1) |
- |
1000 |
|
- |
| As per Clause 6.1(CONSTRUCTION) |
- |
0 |
|
- |
| As per Clause 6.2(CONSTRUCTION) |
- |
0 |
|
- |
| As per Clause 6 - 6.3(CONSTRUCTION) |
- |
0 |
|
- |
| As per Clause 6.4(CONSTRUCTION) |
- |
0 |
|
- |
| As per Clause 7(FINISH) |
- |
0 |
|
- |
| As per Clause 8.1(Flushing tests - Toilet Paper Test) |
- |
0 |
|
- |
| As per Clause 8.2(Flushing tests - Smudge Test) |
- |
0 |
|
- |
| As per Clause 8.3(Flushing tests - Holding Capacity Test) |
- |
0 |
|
- |
| As per Clause 8.4.1(Flushing tests - Single Ball Test) |
- |
0 |
|
- |
| As per Clause 8.4.2(Flushing tests - Fifty Ball Test) |
- |
0 |
|
- |
| As per Clause 8.5(Load Bearing Test) |
- |
0 |
|
- |
| As per Clause 8.6(Flushing tests - Saw Dust Test) |
- |
0 |
|
- |
| As per Clause 8.7(Flushing tests - Splash Test) |
- |
0 |
|
- |
| As per Clause 10(Additional requirements for water effeciency as per IS 17650 part 1) |
- |
0 |
|
- |
| Cl 4(PATTERNS) |
- |
0 |
|
- |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
0 |
|
- |
| (Cl.6) & Cl.6.1(CONSTRUCTIONS) |
- |
0 |
|
- |
| Cl 6.2(CONSTRUCTIONS) |
- |
0 |
|
- |
| Cl 6.3(CONSTRUCTIONS) |
- |
0 |
|
- |
| Cl 6.3(Dimensions and constructions) |
- |
0 |
|
- |
| Cl 6.3(Dimensions and constructions) |
- |
0 |
|
- |
| Cl 6.3(Dimensions and constructions) |
- |
0 |
|
- |
| Cl 6.3(Dimensions and constructions) |
- |
0 |
|
- |
| Cl 6.3(Dimensions and constructions) |
- |
0 |
|
- |
| Cl 6.4(CONSTRUCTIONS) |
- |
0 |
|
- |
| Cl 6.4.1(CONSTRUCTIONS) |
- |
0 |
|
- |
| Cl 7(FINISH) |
- |
0 |
|
- |
| Cl 8 & 8.1(FLUSHING TESTS , toilet paper test) |
- |
0 |
|
- |
| Cl 8.2(Smudge Test :) |
- |
0 |
|
- |
| Cl 8.3(Holding Capacity Test :) |
- |
0 |
|
- |
| Cl 8.4 & 8.4.1(Ball test & single ball test:) |
- |
0 |
|
- |
| Cl 8.4.2(Fifty ball test :) |
- |
0 |
|
- |
| Cl 8.5(Load bearing test :) |
- |
0 |
|
- |
| Cl 8.6(Saw dust test :) |
- |
0 |
|
- |
| Cl 8.7(Splash test :) |
- |
0 |
|
- |
| (Cl. 6) of IS 2556 : 1 (2004)(Permissible blemishes of defects) |
- |
0 |
|
- |
| (Cl. 6) of IS 2556 : 1 (2004) Cl.7(Min thickness) |
- |
0 |
|
- |
| Cl-3(GENERAL REQUIREMENTS) |
- |
500 |
|
- |
| Cl-5(DIMENSIONS AND TOLERANCES) |
- |
0 |
|
- |
| Cl-6(CONSTRUCTIONS) |
- |
0 |
|
- |
| Cl-7(FINISH) |
- |
0 |
|
- |
| Cl-8.1(Toilet Paper Test) |
- |
0 |
|
- |
| Cl-8.2(Smudge Test) |
- |
0 |
|
- |
| Cl-8.3(Holding Capacity Test) |
- |
0 |
|
- |
| Cl-8.4.1(Single Ball Test) |
- |
0 |
|
- |
| Cl-8.4.2(Fifty Ball Test) |
- |
0 |
|
- |
| Cl-8.5(Load Bearing Test) |
- |
0 |
|
- |
| Cl-8.6(Saw Dust Test) |
- |
0 |
|
- |
| Cl-8.7(Splash Test) |
- |
0 |
|
- |
| Cl-10(ADDITIONAL REQUIREMENTS FOR WATER EFFICIENCY) |
- |
0 |
|
- |
| Cl-10(ADDITIONAL REQUIREMENTS FOR WATER EFFICIENCY) |
- |
0 |
|
- |
| Cl-11(Marking) |
- |
0 |
|
- |
| Cl-5, Table-1 (i)(Water surface-Side to side) |
- |
1000 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 13.11.2025 |
| 3644 |
DELHI TEST HOUSE, Azadhpur
| 8131406
| IS 444 (2025) |
Rubber Hoses, Textile-Reinforced, for General-Purpose Water Applications - Specification (Sixth Revision) |
ALL |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5(Material and Construction) |
- |
500 |
|
- |
| Cl-6.1(Internal diameters and tolerances) |
- |
500 |
|
- |
| Cl-6.2(Concentricity) |
- |
500 |
|
- |
| Cl-6.3(Tolerance of length) |
- |
500 |
|
- |
| Cl-6.4(Minimum thickness of lining and cover) |
- |
500 |
|
- |
| Cl-7.1, Table-2 (i)(Minimum tensile strength) |
- |
2000 |
|
-- |
| Cl-7.1, Table-2 (ii)(Minimum elongation at break) |
- |
2000 |
|
- |
| Cl-7.1, Table-2 (iii)("Resistance to ageing:
Change in tensile strength from original value (max) . Change in elongation at break from original value (max)") |
- |
2000 |
|
- |
| Cl-7.2, Table-3 (i)(Proof pressure at 23 0 C) |
- |
2000 |
|
- |
| Cl-7.2, Table-3 (ii)(Change in length at proof pressure) |
- |
2000 |
|
- |
| Cl-7.2, Table-3 (iii)(Minimum burst pressure) |
- |
2500 |
|
- |
| Cl-7.2, Table-3 (iv)(Adhesion between component) |
- |
1500 |
|
- |
| Cl-7.2, Table-3 (v)(Ozone resistance) |
- |
4500 |
|
- |
| Cl-7.2, Table-3 (vi)(Flexibility at 23ºC) |
- |
2000 |
|
- |
| Cl-7.2, Table-3 (vii)(Low-temperature flexibility) |
- |
2000 |
|
- |
| Cl-8(Marking) |
- |
500 |
|
- |
|
17 Jun, 2027 |
- Included w.e.f 26.08.2025 |
| 3645 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 302 : Part 2 : Sec 2 (1997) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 2 vacuum cleaners and water suction cleaning appliances |
- |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Rating) |
- |
100 |
|
Additional Testing Charge For EMI/EMC:- 20,0000/- |
| 6(Classification) |
- |
100 |
|
- |
| 7(Marking) |
- |
500 |
|
- |
| 8(Protection against Access to Live Parts) |
- |
1000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
100 |
|
- |
| 10("Power Input
& Current") |
- |
2500 |
|
- |
| 11(Temperature Rise/ Heating) |
- |
5000 |
|
- |
| 12(OPERATION UNDER OVERLOAD
CONDITIONS OF APPLIANCES WITH
HEATING ELEMENTS) |
- |
100 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE) |
- |
1000 |
|
- |
| 14(RADIO AND TELEVISION
INTERFERENCE SUPPRESSION) |
- |
2500 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
5000 |
|
- |
| 16(INSULATION RESISTANCE AND
ELECTRIC STRENGTH ( AFTER HUMIDITY
TREATMENT )) |
- |
1000 |
|
- |
| 17(OVERLOAD PROTECTION) |
- |
2500 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
5000 |
|
- |
| 20(STABILITY AND MECHANICAL
HAZARDS) |
- |
2500 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
1500 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(INTERNAL WIRING) |
- |
2500 |
|
- |
| 24(COMPONENTS) |
- |
2500 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL
FLEXIBLE CABLES AND CORDS) |
- |
5000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
2500 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
2500 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
1500 |
|
- |
| 29(CREEPAGE DISTANCES, CLEARANCES
AND DISTANCES THROUGH INSULATION) |
- |
5000 |
|
- |
| 30(RESISTANCE TO HEAT, FIRE AND
TRACKING) |
- |
5000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
2500 |
|
- |
| 32(RADIATION HAZARDS) |
- |
2500 |
|
- |
| 19.11.4.7(Harmonics) |
- |
25000 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
25000 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
30000 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
25000 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
25000 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
45000 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
25000 |
|
- |
| 5(Rating) |
- |
0 |
|
- |
| 6(Classification) |
- |
0 |
|
- |
| 7(Marking) |
- |
0 |
|
- |
| 8(Protection against Access to Live Parts) |
- |
0 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 10("Power Input
& Current") |
- |
0 |
|
- |
| 11(Temperature Rise/ Heating) |
- |
0 |
|
- |
| 12(OPERATION UNDER OVERLOAD
CONDITIONS OF APPLIANCES WITH
HEATING ELEMENTS) |
- |
0 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE) |
- |
0 |
|
- |
| 14(RADIO AND TELEVISION
INTERFERENCE SUPPRESSION) |
- |
0 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| 16(INSULATION RESISTANCE AND
ELECTRIC STRENGTH ( AFTER HUMIDITY
TREATMENT )) |
- |
0 |
|
- |
| 17(OVERLOAD PROTECTION) |
- |
0 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
0 |
|
- |
| 20(STABILITY AND MECHANICAL
HAZARDS) |
- |
0 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 23(INTERNAL WIRING) |
- |
0 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL
FLEXIBLE CABLES AND CORDS) |
- |
0 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
0 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
0 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
0 |
|
- |
| 29(CREEPAGE DISTANCES, CLEARANCES
AND DISTANCES THROUGH INSULATION) |
- |
0 |
|
- |
| 30(RESISTANCE TO HEAT, FIRE AND
TRACKING) |
- |
0 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
- |
| 32(RADIATION HAZARDS) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
|
- |
- Included w.e.f. 28.08.2025 |
| 3646 |
IEC TEST LABS LLP
| 8165726
| IS 2465 (1984) |
Specification for cables for motor vehicles (Second Revision) |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Insulation) |
- |
1000 |
|
- |
| 7.3(Insulation) |
- |
1000 |
|
- |
| 8(Core Identification) |
- |
1000 |
|
- |
| 9(Laying up of cores) |
- |
1000 |
|
- |
| 10.1.1(Sheathing ) |
- |
1000 |
|
- |
| 10.2(Sheathing ) |
- |
1000 |
|
- |
| 3 & 6(Flexibility class) |
- |
1000 |
|
- |
| 3 & 6(Construction) |
- |
1000 |
|
- |
| 3 & 6(Diameter of wire(mm)) |
- |
1000 |
|
- |
| 3 & 6(Annealing test) |
- |
1000 |
|
- |
| 3 & 6(Persulphate Test) |
- |
1000 |
|
- |
| 3 & 6(Conductor resistance Test (ohm/km at 20˚c)) |
- |
2000 |
|
- |
| 7.2, 10.3, 11(Dimensions & thickness ) |
- |
2000 |
|
- |
| 7.2, 10.3, 11(Dimensions & thickness ) |
- |
2000 |
|
- |
| 7.2, 10.3, 11(Overall Dimension (mm)) |
- |
2000 |
|
- |
| 4.2 & 12.1(Without Ageing For Insulation
Tensile Strength (N/mm²)) |
- |
2000 |
|
- |
| 4.2 & 12.1, (f), 1(elongation at break (N/mm²)) |
- |
2000 |
|
- |
| 4.2 & 12.1, (f), 1(Tensile Strength at break (N/mm²)) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 1(elongation test at break) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 1(Tensile strength at break) |
- |
2000 |
|
- |
| 4.2 & 12.1, (f), 2(Ageing in air oven) |
- |
3000 |
|
- |
| 4.2 & 12.1, (f), 3(Ageing in oxygen bomb) |
- |
3000 |
|
- |
| 4.2 & 12.1, (e), 2(After Ageing in air oven) |
- |
3000 |
|
- |
| 4.2 & 12.1, (e), 3(Loss of mass test (mg/cm²) of Insulation) |
- |
3000 |
|
- |
| 4.2 & 12.1, (e), 3(Loss of mass test (mg/cm²) of Sheath) |
- |
3000 |
|
- |
| 4.2 & 12.1, (e), 4(Hot deformation test (%) of Insulation) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 4(Hot deformation test (%) of Sheath) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 5(Heat Shock Test of Insulation) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 5(Heat Shock Test of Sheath) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 6(Shrinkage Test (%) of Insulation) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 6(Shrinkage Test (%) of Sheath) |
- |
2000 |
|
- |
| 14(High Voltage Test) |
- |
2000 |
|
- |
| 15(SPARK TEST FOR SINGLE CORE GENERAL WIRING CABLES) |
- |
2000 |
|
- |
| 16.1(CAPACITANCE TEST FOR PVC INSULATION IGNITION CABLE) |
- |
3000 |
|
- |
| 17.1(OZONE RESISTANCE TEST FOR IGNITION CABLES) |
- |
10000 |
|
- |
| 18.1(EFFECT OF HEAT ON FLEXIBILITY FOR IGNITION CABLES) |
- |
3000 |
|
- |
| 19.1(EFFECT OF OIL ON IGNITION CABLES) |
- |
3000 |
|
- |
| 19.2(EFFECT OF OIL ON IGNITION CABLES) |
- |
3000 |
|
- |
| 20.3(EFFECT OF LUBRICATING OIL) |
- |
3000 |
|
- |
| 20.3(EFFECT OF LUBRICATING OIL) |
- |
3000 |
|
- |
| 20.3(EFFECT OF BRAKE FLUID) |
- |
3000 |
|
- |
| 20.3(EFFECT OF BRAKE FLUID) |
- |
3000 |
|
- |
| 20.3(EFFECT OF DIESEL) |
- |
3000 |
|
- |
| 20.3(EFFECT OF DIESEL) |
- |
3000 |
|
- |
| 20.3(Increase in average diameter %) |
- |
3000 |
|
- |
| 20.3(Wrapping test) |
- |
2000 |
|
- |
| 21.1(EFFECT OF COOLING ON FLEXIBILITY) |
- |
3000 |
|
- |
| 21.2(EFFECT OF COOLING ON FLEXIBILITY) |
- |
3000 |
|
- |
| 21.2(EFFECT OF COOLING ON FLEXIBILITY) |
- |
3000 |
|
- |
| 22.1(FLAMMABILITY TEST) |
- |
2000 |
|
- |
| 22.1(FLAMMABILITY TEST) |
- |
2000 |
|
- |
| 23.1(Manufacturer's Identification) |
- |
1000 |
|
- |
| 23.1(Manufacturer's Identification) |
- |
1000 |
|
- |
| 24.1(PACKING AND MARKING) |
- |
1000 |
|
- |
| 24.2(PACKING AND MARKING) |
- |
1000 |
|
- |
| 24.2.1(PACKING AND MARKING) |
- |
1000 |
|
- |
| 12.1.b(Persulphate test (when
applicable)) |
- |
2000 |
|
- |
| 6.1, 12.3, 12.1.c(Conductor Resistance) |
- |
2000 |
|
- |
| 12.1.e4(Hot deformation) |
- |
2000 |
|
- |
| 12.1.e5(Heat Shock) |
- |
2000 |
|
- |
| CL.12.1 (e) 2(Tensile Strength After Ageing) |
- |
3000 |
|
- |
| CL.12.1 (e) 2(Elongation After Ageing) |
- |
3000 |
|
- |
| CL.12.1 (e) 2(Tensile Strength Variation) |
- |
3000 |
|
- |
| CL.12.1 (e) 2(Elongation Variation) |
- |
3000 |
|
- |
| CL.12.1 (e) 2(Elongation Variation) |
- |
3000 |
|
- |
| Cl.12 (e) 5(Heat shock test) |
- |
2000 |
|
- |
| Cl.12 (e) 4(Hot Deformation Test) |
- |
2000 |
|
- |
| Cl.12 (e) 6(Shrinkage Test) |
- |
2000 |
|
- |
| Cl.12 (e) 6(Shrinkage Test (Cracks Observed)) |
- |
2000 |
|
- |
| Cl. 12.1 (e) 3(Loss of Mass Insulation) |
- |
3000 |
|
- |
| 7.1(Insulation) |
- |
1000 |
|
- |
| 7.3(Insulation) |
- |
1000 |
|
- |
| 8(Core Identification) |
- |
1000 |
|
- |
| 9(Laying up of cores) |
- |
1000 |
|
- |
| 10.1.1(Sheathing ) |
- |
1000 |
|
- |
| 10.2(Sheathing ) |
- |
1000 |
|
- |
| 3 & 6(Flexibility class) |
- |
1000 |
|
- |
| 3 & 6(Construction) |
- |
1000 |
|
- |
| 3 & 6(Diameter of wire(mm)) |
- |
1000 |
|
- |
| 3 & 6(Annealing test) |
- |
1000 |
|
- |
| 3 & 6(Persulphate Test) |
- |
2000 |
|
- |
| 3 & 6(Conductor resistance Test (ohm/km at 20˚c)) |
- |
2000 |
|
- |
| 7.2, 10.3, 11(Dimensions & thickness ) |
- |
2000 |
|
- |
| 7.2, 10.3, 11(Dimensions & thickness ) |
- |
2000 |
|
- |
| 7.2, 10.3, 11(Overall Dimension (mm)) |
- |
2000 |
|
- |
| 4.2 & 12.1(Without Ageing For Insulation
Tensile Strength (N/mm²)) |
- |
2000 |
|
- |
| 4.2 & 12.1, (f), 1(elongation at break (N/mm²)) |
- |
2000 |
|
- |
| 4.2 & 12.1, (f), 1(Tensile Strength at break (N/mm²)) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 1(elongation test at break) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 1(Tensile strength at break) |
- |
2000 |
|
- |
| 4.2 & 12.1, (f), 2(Ageing in air oven) |
- |
2000 |
|
- |
| 4.2 & 12.1, (f), 3(Ageing in oxygen bomb) |
- |
3000 |
|
- |
| 4.2 & 12.1, (e), 2(After Ageing in air oven) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 3(Loss of mass test (mg/cm²) of Insulation) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 3(Loss of mass test (mg/cm²) of Sheath) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 4(Hot deformation test (%) of Insulation) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 4(Hot deformation test (%) of Sheath) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 5(Heat Shock Test of Insulation) |
- |
1000 |
|
- |
| 4.2 & 12.1, (e), 5(Heat Shock Test of Sheath) |
- |
1000 |
|
- |
| 4.2 & 12.1, (e), 6(Shrinkage Test (%) of Insulation) |
- |
1000 |
|
- |
| 4.2 & 12.1, (e), 6(Shrinkage Test (%) of Sheath) |
- |
1000 |
|
- |
| 14(High Voltage Test) |
- |
2000 |
|
- |
| 15(SPARK TEST FOR SINGLE CORE GENERAL WIRING CABLES) |
- |
2000 |
|
- |
| 16.1(CAPACITANCE TEST FOR PVC INSULATION IGNITION CABLE) |
- |
3000 |
|
- |
| 17.1(OZONE RESISTANCE TEST FOR IGNITION CABLES) |
- |
5000 |
|
- |
| 18.1(EFFECT OF HEAT ON FLEXIBILITY FOR IGNITION CABLES) |
- |
5000 |
|
- |
| 19.1(EFFECT OF OIL ON IGNITION CABLES) |
- |
5000 |
|
- |
| 19.2(EFFECT OF OIL ON IGNITION CABLES) |
- |
3000 |
|
- |
| 20.3(EFFECT OF LUBRICATING OIL) |
- |
3000 |
|
- |
| 20.3(EFFECT OF LUBRICATING OIL) |
- |
3000 |
|
- |
| 20.3(EFFECT OF BRAKE FLUID) |
- |
3000 |
|
- |
| 20.3(EFFECT OF BRAKE FLUID) |
- |
3000 |
|
- |
| 20.3(EFFECT OF DIESEL) |
- |
2000 |
|
- |
| 20.3(EFFECT OF DIESEL) |
- |
2000 |
|
- |
| 20.3(Increase in average diameter %) |
- |
2000 |
|
- |
| 20.3(Wrapping test) |
- |
2000 |
|
- |
| 21.1(EFFECT OF COOLING ON FLEXIBILITY) |
- |
2000 |
|
- |
| 21.2(EFFECT OF COOLING ON FLEXIBILITY) |
- |
2000 |
|
- |
| 21.2(EFFECT OF COOLING ON FLEXIBILITY) |
- |
2000 |
|
- |
| 22.1(FLAMMABILITY TEST) |
- |
2000 |
|
- |
| 22.1(FLAMMABILITY TEST) |
- |
2000 |
|
- |
| 23.1(Manufacturer's Identification) |
- |
1000 |
|
- |
| 23.1(Manufacturer's Identification) |
- |
1000 |
|
- |
| 24.1(PACKING AND MARKING) |
- |
1000 |
|
- |
| 24.2(PACKING AND MARKING) |
- |
1000 |
|
- |
| 24.2.1(PACKING AND MARKING) |
- |
1000 |
|
- |
| 12.1.b(Persulphate test (when
applicable)) |
- |
2000 |
|
- |
| 6.1, 12.3, 12.1.c(Conductor Resistance) |
- |
2000 |
|
- |
| 12.1.e4(Hot deformation) |
- |
2000 |
|
- |
| 12.1.e5(Heat Shock) |
- |
1000 |
|
- |
| CL.12.1 (e) 2(Tensile Strength After Ageing) |
- |
3000 |
|
- |
| CL.12.1 (e) 2(Elongation After Ageing) |
- |
3000 |
|
- |
| CL.12.1 (e) 2(Tensile Strength Variation) |
- |
3000 |
|
- |
| CL.12.1 (e) 2(Elongation Variation) |
- |
3000 |
|
- |
| CL.12.1 (e) 2(Elongation Variation) |
- |
3000 |
|
- |
| Cl.12 (e) 5(Heat shock test) |
- |
1000 |
|
- |
| Cl.12 (e) 4(Hot Deformation Test) |
- |
2000 |
|
- |
| Cl.12 (e) 6(Shrinkage Test) |
- |
1000 |
|
- |
| Cl.12 (e) 6(Shrinkage Test (Cracks Observed)) |
- |
1000 |
|
- |
| Cl. 12.1 (e) 3(Loss of Mass Insulation) |
- |
3000 |
|
- |
|
07 Sep, 2026 |
- Included w.e.f. 29.09.2025 |
| 3647 |
Aaditech Test and Calibration Lab LLP
| 8179926
| IS 302 : Part 2 : Sec 23 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 23 appliances for skin or hair care (First Revision) |
Their rated voltage being not more than 250 V |
18000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32(Radiation ,Toxicity and similar hazards) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
1000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
500 |
|
- |
| 28(Screws & Connection) |
- |
500 |
|
- |
| 27(Provision For Earthing) |
- |
500 |
|
- |
| 26(Terminals For External Conductors) |
- |
500 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
2000 |
|
- |
| 24(Component) |
- |
500 |
|
- |
| 23(Internal wiring) |
- |
1000 |
|
- |
| 22(Construction) |
- |
1000 |
|
- |
| 21(Mechanical strength) |
- |
1000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
0 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
1000 |
|
- |
| 15(Moisture Resistance) |
- |
2000 |
|
- |
| 14(Transient Over Voltage) |
- |
0 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
1000 |
|
- |
| 11(Temperature Rise/Heating) |
- |
1000 |
|
- |
| 10(Power Input
& Current) |
- |
500 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
500 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
500 |
|
- |
| 6(Classification) |
- |
500 |
|
- |
| 22.32(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
0 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
0 |
|
- |
| 28(Screws & Connection) |
- |
0 |
|
- |
| 27(Provision For Earthing) |
- |
0 |
|
- |
| 26(Terminals For External Conductors) |
- |
0 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
0 |
|
- |
| 24(Component) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
0 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
0 |
|
- |
| 15(Moisture Resistance) |
- |
0 |
|
- |
| 14(Transient Over Voltage) |
- |
0 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
0 |
|
- |
| 11(Temperature Rise/Heating) |
- |
0 |
|
- |
| 10(Power Input
& Current) |
- |
0 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
0 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
0 |
|
- |
| 6(Classification) |
- |
0 |
|
- |
| 22.32(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
0 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
0 |
|
- |
| 28(Screws & Connection) |
- |
0 |
|
- |
| 27(Provision For Earthing) |
- |
0 |
|
- |
| 26(Terminals For External Conductors) |
- |
0 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
0 |
|
- |
| 24(Component) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
0 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
0 |
|
- |
| 15(Moisture Resistance) |
- |
0 |
|
- |
| 14(Transient Over Voltage) |
- |
0 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
0 |
|
- |
| 11(Temperature Rise/Heating) |
- |
0 |
|
- |
| 10(Power Input
& Current) |
- |
0 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
0 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
0 |
|
- |
| 6(Classification) |
- |
0 |
|
- |
| 22.32(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
0 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
0 |
|
- |
| 28(Screws & Connection) |
- |
0 |
|
- |
| 27(Provision For Earthing) |
- |
0 |
|
- |
| 26(Terminals For External Conductors) |
- |
0 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
0 |
|
- |
| 24(Component) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
0 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
0 |
|
- |
| 15(Moisture Resistance) |
- |
0 |
|
- |
| 14(Transient Over Voltage) |
- |
0 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
0 |
|
- |
| 11(Temperature Rise/Heating) |
- |
0 |
|
- |
| 10(Power Input
& Current) |
- |
0 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
0 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
0 |
|
- |
| 6(Classification) |
- |
0 |
|
- |
| 22.32(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
0 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
0 |
|
- |
| 28(Screws & Connection) |
- |
0 |
|
- |
| 27(Provision For Earthing) |
- |
0 |
|
- |
| 26(Terminals For External Conductors) |
- |
0 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
0 |
|
- |
| 24(Component) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
0 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
0 |
|
- |
| 15(Moisture Resistance) |
- |
0 |
|
- |
| 14(Transient Over Voltage) |
- |
0 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
0 |
|
- |
| 11(Temperature Rise/Heating) |
- |
0 |
|
- |
| 10(Power Input
& Current) |
- |
0 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
0 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
0 |
|
- |
| 6(Classification) |
- |
0 |
|
- |
| 22.32(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
0 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
0 |
|
- |
| 28(Screws & Connection) |
- |
0 |
|
- |
| 27(Provision For Earthing) |
- |
0 |
|
- |
| 26(Terminals For External Conductors) |
- |
0 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
0 |
|
- |
| 24(Component) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
0 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
0 |
|
- |
| 15(Moisture Resistance) |
- |
0 |
|
- |
| 14(Transient Over Voltage) |
- |
0 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
0 |
|
- |
| 11(Temperature Rise/Heating) |
- |
0 |
|
- |
| 10(Power Input
& Current) |
- |
0 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
0 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
0 |
|
- |
| 6(Classification) |
- |
0 |
|
- |
| 22.32(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
|
- |
- Included w.e.f.03.09.2025
Exclusion
"19.11.4.1 TO 19.11.4.7 EMI/EMC
32 (Radiation ,Toxicity and similar hazards)
24 (Component)" |
| 3648 |
ALPHA TEST HOUSE PVT LTD, BAHADURGARH
| 8185306
| IS 16270 (2023) |
Secondary cells and batteries for solar photovoltaic application - General requirements and methods of test |
- |
550000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1(Photovoltaic Energy System) |
- |
550000 |
|
- |
| Cl-4.2(Secondary Cells and Batteries) |
- |
550000 |
|
- |
| Cl-4.3(General Operating Conditions) |
- |
550000 |
|
- |
| Cl-4.3.8(Storage) |
- |
550000 |
|
- |
| Cl-4.3.9(Operating Temperature) |
- |
550000 |
|
- |
| Cl-5.1(Mechanical Endurance) |
- |
550000 |
|
- |
| Cl-5.2(Charge Efficiency) |
- |
550000 |
|
- |
| Cl-5.3(Deep Discharge Protection) |
- |
550000 |
|
- |
| Cl-5.4(Marking) |
- |
550000 |
|
- |
| Cl-5.5(Safety) |
- |
550000 |
|
- |
| Cl-5.6(Documentation) |
- |
550000 |
|
- |
| Cl-6(Functional characteristice) |
- |
550000 |
|
- |
| Cl-7(General test conditions) |
- |
550000 |
|
- |
| Cl-8.1(Capacity Test) |
- |
550000 |
|
- |
| Cl-8.2(Endurance Test) |
- |
550000 |
|
- |
| Cl-8.3(Charge Retention Test) |
- |
550000 |
|
- |
| Cl-8.4(Cycle Endurance in Photovoltaic Application (Extreme Conditions)) |
- |
550000 |
|
- |
| Cl-8.5(Sulphation Test (Applicable for Lead Acid Batteries only)) |
- |
550000 |
|
- |
| Cl-8.6(Water Loss Test (Valid for Flooded Lead Acid Batteries only)) |
- |
550000 |
|
- |
| Cl-9.1(Type Tests) |
- |
550000 |
|
- |
| Cl-9.2(Acceptance Test) |
- |
550000 |
|
- |
| 4.3.7.1(Specific gravity) |
- |
550000 |
|
- |
|
08 May, 2028 |
- Included w.e.f. 28.08.2025 |
| 3649 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 737 (2024) |
WROUGHT ALUMINIUM AND ALUMINIUM ALLOY SHEET AND STRIP FOR GENERAL ENGINEERING PURPOSES SPECIFICATION (Fifth Revision) |
- |
14500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4(Ordering Information - IS 737) |
- |
14500 |
|
- |
| Cl. 4 (a)(Grade/ Thickness - IS 737) |
- |
14500 |
|
- |
| Cl. 4 (b)(Condition - IS 737) |
- |
14500 |
|
- |
| Cl. 4 (c)(Quantity in Kg - IS 737) |
- |
14500 |
|
- |
| Cl. 4 (d)(Size - Thickness X Width X Length (T X W X L) in mm for sheets and (T X W) in mm for Strips/ Coils - IS 737) |
- |
14500 |
|
- |
| Cl. 4 (e)(Coil ID and Coil Weight for Strips/ Coils - IS 737) |
- |
14500 |
|
- |
| Cl. 4 (f)(Core/ Spool Requirement for Coils - IS 737) |
- |
14500 |
|
- |
| Cl. 4 (g)(Packing Mode - IS 737) |
- |
14500 |
|
- |
| Cl. 5(Supply for Material - IS 737/ IS 10259) |
- |
14500 |
|
- |
| Cl. 6(Freedom from Defects - IS 737) |
- |
14500 |
|
- |
| Cl. 7(Chemical Composition - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Si - IS 504 (Part-1)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Fe - IS 504 (Part-2)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Cu - IS 504 (Part-3)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Mn - IS 504 (Part-5)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Mg - IS 504 (Part-6)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Cr - IS 504 (Part-8)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Zn - IS 504 (Part-4)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Ti - IS 504 (Part-11)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Others (Each) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Others (Total) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Al - IS 504) |
- |
14500 |
|
- |
| Cl. 8(Mechanical Properties - IS 1608 (Part-1)) |
- |
14500 |
|
- |
| Cl. 8.1(0.2% Proof Stress - IS 1608 (Part-1)) |
- |
14500 |
|
- |
| Cl. 8.1(Tensile Strength - IS 1608 (Part-1)) |
- |
14500 |
|
- |
| Cl. 8.1(Elongation on 50mm Gauge Length - IS 1608 (Part-1)) |
- |
14500 |
|
- |
| Cl. 8.2(Bend Test - IS 1599) |
- |
14500 |
|
- |
| Cl. 9(Condition - IS 737/ IS 5052) |
- |
14500 |
|
- |
| Cl. 10(Dimensions and Tolerances - IS 737/ IS 2676) |
- |
14500 |
|
- |
| Cl. 11(Selection of Test Samples - IS 737) |
- |
14500 |
|
- |
| Cl. 11.1(Sheet and Strip of Aluminium or Non - Heat Treatable Aluminium Alloy - IS 737) |
- |
14500 |
|
- |
| Cl. 11.2(Sheet and Strip of Heat - Treatable Aluminium Alloys - IS 737) |
- |
14500 |
|
- |
| Cl. 12(Retests - IS 737/ IS 10259) |
- |
14500 |
|
- |
| Cl. 13(Packaging - IS 737/ IS 10259) |
- |
14500 |
|
- |
| Cl. 13.1(Marking - IS 737) |
- |
14500 |
|
- |
|
- |
- Included w.e.f.01.09.2025 |
| 3650 |
National Test House (NR) - NTH, Ghaziabad
| 8101304
| IS 11544 (1986) |
Specification for slipper, rubber |
- |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2.6(Thickness of components) |
- |
0 |
|
- |
| 3.2.5(Type of Thread) |
- |
0 |
|
- |
| 3.2.4(Colour fasntess to washing) |
- |
0 |
|
- |
| 3.2.4(Picks per cm) |
- |
0 |
|
- |
| 3.2.4(End per cm) |
- |
0 |
|
- |
| 3.2.4(Mass per unit area) |
- |
0 |
|
- |
| 3.2(Flexural endurance) |
- |
0 |
|
- |
| 3.2(Hardness after ageing) |
- |
0 |
|
- |
| 3.2(Relative density ) |
- |
0 |
|
- |
| 3.1(Shape & Design) |
- |
0 |
|
- |
| 3.2.2(Bottom Filling Material) |
- |
0 |
|
- |
| 3.2.4.1(Weave of fabrics) |
- |
0 |
|
- |
| 3.2.7(vulcanized process) |
- |
0 |
|
- |
| 3.2.8(Workmanship and Finish -) |
- |
0 |
|
- |
| 3.2.9(Preservation -) |
- |
0 |
|
- |
| Cl. 4, Cl. 4.1, Cl 4.2, Cl. 4.3(Marking and packing) |
- |
0 |
|
- |
| Cl. 4, Cl. 4.1,Cl 4.2(Marking and packing) |
- |
0 |
|
- |
| 3.2(Hardness (IRHD)) |
- |
0 |
|
- |
|
26 Oct, 2028 |
- Included w.e.f.18.08.2025 |
| 3651 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/41), GHAZIABAD
| 9179706
| IS 5676 (1995) |
Moulded solid rubber soles and heels - SpecificatlOn (Second Revision) |
ALL |
7500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5/5.3/5.3.1(REQUIREMENTS- Construction) |
- |
700 |
|
- |
| 5/5.1(REQUIREMENTS-General) |
- |
500 |
|
- |
| 5/5.2- Fig. 1 to 5(REQUIREMENTS-Design) |
- |
500 |
|
- |
| 5/5.5- Table1(REQUIREMENTS-Thickness) |
- |
400 |
|
- |
| 5/5.6/5.6.1(REQUIREMENTS-Channel) |
- |
400 |
|
- |
| 5/5.7- Table2(REQUIREMENTS- Physical Requirements-
as per IS 3400 (Part 1, Part 2, Part 4, Part 9, Part 10, Part 16)) |
- |
700 |
|
- |
| 5/5.3/5.3.1(REQUIREMENTS- Construction) |
- |
400 |
|
- |
| 5/5.1(REQUIREMENTS-General) |
- |
400 |
|
- |
| 5/5.2- Fig. 1 to 5(REQUIREMENTS-Design) |
- |
400 |
|
- |
| 5/5.5- Table1(REQUIREMENTS-Thickness) |
- |
400 |
|
- |
| 5/5.6/5.6.1(REQUIREMENTS-Channel) |
- |
400 |
|
- |
| 5/5.7- Table2(REQUIREMENTS- Physical Requirements-
as per IS 3400 (Part 1, Part 2, Part 4, Part 9, Part 10, Part 16)) |
- |
700 |
|
- |
| 5/5.3/5.3.1(REQUIREMENTS- Construction) |
- |
700 |
|
- |
| 5/5.1(REQUIREMENTS-General) |
- |
400 |
|
- |
| 5/5.2- Fig. 1 to 5(REQUIREMENTS-Design) |
- |
400 |
|
- |
| 5/5.5- Table1(REQUIREMENTS-Thickness) |
- |
400 |
|
- |
| 5/5.6/5.6.1(REQUIREMENTS-Channel) |
- |
400 |
|
- |
| 5/5.7- Table2(REQUIREMENTS- Physical Requirements-
as per IS 3400 (Part 1, Part 2, Part 4, Part 9, Part 10, Part 16)) |
- |
700 |
|
- |
| 6(Marking and packing) |
- |
500 |
|
- |
| 8.1(Test methods) |
- |
800 |
|
- |
| 8.3(Measurement of thickness) |
- |
400 |
|
- |
| Cl.6.1,6.2,6.3(Marking and packing) |
- |
500 |
|
- |
| 8.1(Test Methods) |
- |
800 |
|
- |
| Cl.8.3(Measurement of thickness ") |
- |
400 |
|
- |
| 5.5 (Amendment 1)(Thickness) |
- |
400 |
|
- |
| 5.7 Table 2 i) (Amendment 1)(Relative Density) |
- |
500 |
|
- |
| 5.7, Table 2 ii) (Amendment 1)(Hardness, degree, Shore A) |
- |
400 |
|
- |
| 5.7, Table 2 iv) (Amendment 1)(Abrasion Resistance at applied force of 10 N) |
- |
700 |
|
- |
| 5.7, Table 2 v) (Amendment 1)(Tensile strength) |
- |
1000 |
|
- |
| 5.7, Table 2 vi) (Amendment 1)(Elongation at break) |
- |
1000 |
|
- |
| 5.7, Table 2 vii) (Amendment 1)(Tear strength (average force)) |
- |
1000 |
|
- |
| 5.7, Table 2 iii) (Amendment 1)(Flexing resistance) |
- |
1000 |
|
- |
|
- |
- Included w.e.f.18.08.2025 |
| 3652 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 15658 (2021) |
Concrete Paving Blocks - Specification ( First Revision ) |
- |
12500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 50 cycles) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 25 cycles) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 10 cycles) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Cumulative Weight losses of specimen after 10, 25 & 50 cycles) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 50 cycles) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 25 cycles) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 10 cycles) |
- |
0 |
|
- |
| Clause 7.3, Annex G(Average Breaking Load) |
- |
1000 |
|
- |
| Clause 7.3, Annex G(Individual Breaking Load) |
- |
1000 |
|
- |
| Clause 7.3, Annex F(Average Failure Load per unit Length) |
- |
1000 |
|
- |
| Clause 7.3, Annex F(Individual Failure Load per unit Length) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) b)(Average Flexural strength ) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) a)(Indivdual Flexural strength (i)) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) b)(Average Tensile splitting strength ) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) a)(Indivdual Tensile splitting strength (i)) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) ii)(Wet Abrasion resistance (Average of three test specimens)) |
- |
3000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) i)( Indivdual Wet Abrasion Resistance ) |
- |
3000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) ii)(Dry Abrasion resistance (Average of three test specimens)) |
- |
3000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) i)( Indivdual Dry Abrasion Resistance ) |
- |
3000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) b)(Compressive strength (Average of eight test specimens)) |
- |
3000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) a)(Indivdual Compressive strength (i)) |
- |
3000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) b)(Water absorption (Average of three test specimens)) |
- |
3000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) a)( Indivdual Water absorption) |
- |
3000 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (ix)(Deviation from squareness) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Indivdual Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Indivdual Plan Area (Asp)) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Plan Area (Asp)) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Indivdual Thickness of wearing Layer) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Thickness of wearing Layer) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Indivdual Arris/chamfer, Depth) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Depth) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Indivdual Arris/chamfer, Width) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Width) |
- |
1500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iv)
(Indivdual Aspect Ratio, L/Th) |
- |
1500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iv)
(Aspect Ratio, L/Th) |
- |
1500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iii)
(Indivdual Thickness, Th) |
- |
1500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iii)
(Thickness, Th) |
- |
1500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (ii)
(Indivdual Length, L) |
- |
1500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (ii)
(Length, L) |
- |
1500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (i)
(Indivdual Width, W) |
- |
1500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (i)
(Width, W) |
- |
1500 |
|
- |
| Clauses 7.1.2 & 9.1.2
(Visual Inspection) |
- |
1000 |
|
- |
| Clause 7.1.1
(General Quality) |
- |
1000 |
|
- |
| 7.2- TABLE-2- (i) IS-15658 (Annex-B)(Individual Width - Lower) |
- |
1500 |
|
- |
| 7.2- TABLE-2- (i) IS-15658 (Annex-B)(Average Width -Lower) |
- |
1500 |
|
- |
| 7.2- TABLE-2- (i) IS-15658 (Annex-B)(Individual Width - Higher) |
- |
1500 |
|
- |
| 7.2- TABLE-2- (i) IS-15658 (Annex-B)(Average Width -Higher) |
- |
1500 |
|
- |
| Clause 3.20(Spacer nibs) |
- |
1500 |
|
- |
| 5.4(Coarse and Fine
Aggregates) |
- |
0 |
|
- |
| 5.6(Water) |
- |
0 |
|
- |
| Clause 7.3, Annex G(Average Breaking Load) |
- |
0 |
|
- |
| Clause 7.3, Annex G(Individual Breaking Load) |
- |
0 |
|
- |
| Clause 7.3, Annex F(Average Failure Load per unit Length) |
- |
0 |
|
- |
| Clause 7.3, Annex F(Individual Failure Load per unit Length) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) b)(Average Flexural strength ) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) a)(Indivdual Flexural strength (i)) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) b)(Average Tensile splitting strength ) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) a)(Indivdual Tensile splitting strength (i)) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) ii)(Wet Abrasion resistance (Average of three test specimens)) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) i)( Indivdual Wet Abrasion Resistance ) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) ii)(Dry Abrasion resistance (Average of three test specimens)) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) i)( Indivdual Dry Abrasion Resistance ) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) b)(Compressive strength (Average of eight test specimens)) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) a)(Indivdual Compressive strength (i)) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) b)(Water absorption (Average of three test specimens)) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) a)( Indivdual Water absorption) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (ix)(Deviation from squareness) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Indivdual Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Indivdual Plan Area (Asp)) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Plan Area (Asp)) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Indivdual Thickness of wearing Layer) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Thickness of wearing Layer) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Indivdual Arris/chamfer, Depth) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Depth) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Indivdual Arris/chamfer, Width) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Width) |
- |
0 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iv)
(Indivdual Aspect Ratio, L/Th) |
- |
0 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iv)
(Aspect Ratio, L/Th) |
- |
0 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iii)
(Indivdual Thickness, Th) |
- |
0 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iii)
(Thickness, Th) |
- |
0 |
|
- |
| Clause 7.2, Table No. 2, SI No. (ii)
(Indivdual Length, L) |
- |
0 |
|
- |
| Clause 7.2, Table No. 2, SI No. (ii)
(Length, L) |
- |
0 |
|
- |
| Clause 7.2, Table No. 2, SI No. (i)
(Indivdual Width, W) |
- |
0 |
|
- |
| Clause 7.2, Table No. 2, SI No. (i)
(Width, W) |
- |
0 |
|
- |
| Clauses 7.1.2 & 9.1.2
(Visual Inspection) |
- |
0 |
|
- |
| Clause 7.1.1
(General Quality) |
- |
0 |
|
- |
| 7.2- TABLE-2- (i) IS-15658 (Annex-B)(Individual Width - Lower) |
- |
0 |
|
- |
| 7.2- TABLE-2- (i) IS-15658 (Annex-B)(Average Width -Lower) |
- |
0 |
|
- |
| 7.2- TABLE-2- (i) IS-15658 (Annex-B)(Individual Width - Higher) |
- |
0 |
|
- |
| 7.2- TABLE-2- (i) IS-15658 (Annex-B)(Average Width -Higher) |
- |
0 |
|
- |
| Clause 3.20(Spacer nibs) |
- |
0 |
|
- |
|
- |
- - |
| 3653 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 18166 (2025) |
Unplasticized Polyvinyl Chloride PVC-U Threaded Column Pipes for Borewells/Tubewells - Specification |
For all nominal size and class |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5 (COLOUR) |
- |
|
|
|
| 6 (CLASSIFICATION) |
- |
|
|
|
| 7, Table - 2,3,4,7 (DIMENSIONS) |
- |
|
|
|
| 8.3 , Table 5, 6 (Basic Thread Dimensions) |
- |
|
|
|
| 9.1 (Visual Appearance) |
- |
|
|
|
| 9.2 (Resistance to External Blows at 0 °C) |
- |
|
|
|
| 9.4 (Tensile Strength) |
- |
|
|
|
| 9.4 (Elongation at Break) |
- |
|
|
|
| 9.8 (Density) |
- |
|
|
|
| 9.9 (Vicat Softening Temperature) |
- |
|
|
|
| 8.1 (Column Pipes) |
- |
|
|
|
| 8.2 (Column Couplers) |
- |
|
|
|
| 8.4 (Sealing rings and elements made of elastomeric material such as EPDM,) |
- |
|
|
|
| 9.6 (Izod Impact Strength Test) |
- |
|
|
|
| 9.9 (Vicat Softening Temperature) |
- |
|
|
|
| 8.1 (Column Pipes) |
- |
|
|
|
| 8.2 (Column Couplers) |
- |
|
|
|
| 8.4 (Sealing rings and elements made of elastomeric material such as EPDM,) |
- |
|
|
|
| 9.5 , Table- 9 (Ultimate Breaking Load) |
- |
|
|
|
| 9.11 (Hydrostatic Pressure Test) |
- |
|
|
|
| 9.12 (Joint Leak Pressure Test) |
- |
|
|
|
| 9.3 (Flattening Test) |
- |
|
|
|
| 9.7 (Resistance to DCM) |
- |
|
|
|
| 9. 10 (Effect on Water Lead (first extraction)) |
- |
|
|
|
| 9. 10 (Effect on Water Lead (third extraction)) |
- |
|
|
|
| 9. 10 (Effect on Water Dialkyl tin C4 and higher homologues(measured as tin )(third extraction )) |
- |
|
|
|
| 9. 10 (Effect on Water Cadmium (mean of first extraction, second extraction and third extraction)) |
- |
|
|
|
| 9. 10 (Effect on Water Mercury (mean of first extraction, second extraction and third extraction)) |
- |
|
|
|
|
- |
- Except 9.5 Ultimate Breaking Load, 9.6 Izod Impact Strength Test, 9.11 Hydrostatic Pressure Test, 9.12 Joint Leak Pressure Test, 9.3 Flattening Test.
Sample required- 16 pieces pipes approx 1 m (Mechanical- 10 pc and chemical- 6 pc) |
| 3654 |
National Test House (NR) - NTH, Ghaziabad
| 8101304
| IS 6719 (1972) |
Solid Pvc Soles And Heels |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.6.1(Hardness ) |
- |
0 |
|
- |
| 3.6 (vi)(Lead (as Pb) ppm) |
- |
0 |
|
- |
| 3.6 (v)(Volatility, percent by means ) |
- |
0 |
|
- |
| 3.6 (iv)(Tear Strength a) Force Part b) Back Part ) |
- |
0 |
|
- |
| 3.6 (iii)(Elongation at break, percent ) |
- |
0 |
|
- |
| 3.6 (ii)(Tensile Strength ) |
- |
0 |
|
- |
| 3.6 (i)(Relative density ) |
- |
0 |
|
- |
| Cl. 3.1,3.2,3.3,3.4,3.5(Material) |
- |
0 |
|
- |
| 6 ,6.1,6.2,6.3(Test Method) |
- |
0 |
|
- |
| Cl. 3.1,3.2,3.3,3.4,3.5(Material) |
- |
0 |
|
- |
| Cl. 6.4(Measurement of thickness) |
- |
0 |
|
- |
| Table 1 (Flexing resistance)(Table 1 (Flexing resistance, Bennewart method, cut growth at the end of 30 000 cycles, mm, Max)) |
- |
0 |
|
- |
| Table 1 (Abrasion resistance)(Abrasion resistance at applied
force of 10 N (volume loss),
mm3, Max) |
- |
0 |
|
- |
| Table 1 Cl. 3.6, Sl No (iii)(Volatility, Percent by mass) |
- |
0 |
|
- |
| Table 1 Cl. 3.6, Sl No (iv)("Lead (as Pb), Shoes for
infants, children and
boys and girls, ppm") |
- |
0 |
|
- |
| Table 1 Cl. 3.6, Sl No (iv)("Lead (as Pb), for other sized shoes, ppm
") |
- |
0 |
|
- |
| 3.6.1(Hardness ) |
- |
0 |
|
- |
| 3.6 (vi)(Lead (as Pb) ppm) |
- |
0 |
|
- |
| 3.6 (v)(Volatility, percent by means ) |
- |
0 |
|
- |
| 3.6 (iv)(Tear Strength a) Force Part b) Back Part ) |
- |
0 |
|
- |
| 3.6 (iii)(Elongation at break, percent ) |
- |
0 |
|
- |
| 3.6 (ii)(Tensile Strength ) |
- |
0 |
|
- |
| 3.6 (i)(Relative density ) |
- |
0 |
|
- |
| Cl. 3.1,3.2,3.3,3.4,3.5(Material) |
- |
0 |
|
- |
| 6 ,6.1,6.2,6.3(Test Method) |
- |
0 |
|
- |
| Cl. 3.1,3.2,3.3,3.4,3.5(Material) |
- |
0 |
|
- |
| Cl. 6.4(Measurement of thickness) |
- |
0 |
|
- |
| Table 1 (Flexing resistance)(Table 1 (Flexing resistance, Bennewart method, cut growth at the end of 30 000 cycles, mm, Max)) |
- |
0 |
|
- |
| Table 1 (Abrasion resistance)(Abrasion resistance at applied
force of 10 N (volume loss),
mm3, Max) |
- |
0 |
|
- |
| Table 1 Cl. 3.6, Sl No (iii)(Volatility, Percent by mass) |
- |
0 |
|
- |
| Table 1 Cl. 3.6, Sl No (iv)("Lead (as Pb), Shoes for
infants, children and
boys and girls, ppm") |
- |
0 |
|
- |
| Table 1 Cl. 3.6, Sl No (iv)("Lead (as Pb), for other sized shoes, ppm
") |
- |
0 |
|
- |
| 3.6.1(Hardness ) |
- |
0 |
|
- |
| 3.6 (vi)(Lead (as Pb) ppm) |
- |
0 |
|
- |
| 3.6 (v)(Volatility, percent by means ) |
- |
0 |
|
- |
| 3.6 (iv)(Tear Strength a) Force Part b) Back Part ) |
- |
0 |
|
- |
| 3.6 (iii)(Elongation at break, percent ) |
- |
0 |
|
- |
| 3.6 (ii)(Tensile Strength ) |
- |
0 |
|
- |
| 3.6 (i)(Relative density ) |
- |
0 |
|
- |
| Cl. 3.1,3.2,3.3,3.4,3.5(Material) |
- |
0 |
|
- |
| 6 ,6.1,6.2,6.3(Test Method) |
- |
0 |
|
- |
| Cl. 3.1,3.2,3.3,3.4,3.5(Material) |
- |
0 |
|
- |
| Cl. 6.4(Measurement of thickness) |
- |
0 |
|
- |
| Table 1 (Flexing resistance)(Table 1 (Flexing resistance, Bennewart method, cut growth at the end of 30 000 cycles, mm, Max)) |
- |
0 |
|
- |
| Table 1 (Abrasion resistance)(Abrasion resistance at applied
force of 10 N (volume loss),
mm3, Max) |
- |
0 |
|
- |
| Table 1 Cl. 3.6, Sl No (iii)(Volatility, Percent by mass) |
- |
0 |
|
- |
| Table 1 Cl. 3.6, Sl No (iv)("Lead (as Pb), Shoes for
infants, children and
boys and girls, ppm") |
- |
0 |
|
- |
| Table 1 Cl. 3.6, Sl No (iv)("Lead (as Pb), for other sized shoes, ppm
") |
- |
0 |
|
- |
|
26 Oct, 2028 |
- Included w.e.f.18.08.2025 |
| 3655 |
DELHI TEST HOUSE (65) KUNDLI-2 SONIPAT
| 9138006
| IS 398 : Part 2 (2025) |
Aluminium Conductor for Overhead Transmission Purposes - Specification Part 2 Aluminium Conductors Galvanized Steel Reinforced (Fourth Revision) |
-- |
38450 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-6(Material) |
- |
500 |
|
- |
| Cl-6.1.1(chemical composition of high carbon steel) |
- |
2000 |
|
- |
| Cl-6.2(zinc used for galvanizing) |
- |
1000 |
|
- |
| Cl-7(Freedom From Defects) |
- |
500 |
|
- |
| Cl-8.1(Wires-Nominal Sizes) |
- |
500 |
|
- |
| Cl-8.2(Aluminum Conductors, Galvanized Steel- Reinforced) |
- |
500 |
|
- |
| Cl-9.1(Joint in Wires) |
- |
500 |
|
- |
| Cl-9.2(Aluminium Wires) |
- |
500 |
|
- |
| Cl-9.3(Galvanized Steel Wires) |
- |
1000 |
|
- |
| Cl-10.2(Lay Ratio of Aluminium Conductors Galvanized Steel-Reinforced) |
- |
750 |
|
- |
| Cl-13.3(Conductor- Visual examination) |
- |
200 |
|
- |
| Cl- 13.5(Conductor- Measurement of lay ratio/direction of lay) |
- |
2500 |
|
- |
| Cl- 13.12(Conductor- d.c. Resistance test on stranded conductor) |
- |
3500 |
|
- |
| Cl- 13.14(Conductor- Ultimate tensile strength test on stranded conductor) |
- |
5000 |
|
- |
| Cl- 13.13(Conductor- Surface condition test on stranded conductor) |
- |
6000 |
|
- |
| Cl- 13.15(Conductor- Corona test (for conductors intended for use at 400 kV and above voltage level for a.c. and ± 320 kV and above voltage level for d.c.)) |
- |
0 |
|
- |
| Cl-13.16(Conductor- Radio interference voltage test) |
- |
0 |
|
- |
| Cl-13.4(Aluminium wires-Measurement of diameter) |
- |
1000 |
|
- |
| Cl- 13.6(Aluminium wires -Breaking load test) |
- |
1000 |
|
- |
| Cl- 13.8(Aluminium wires- Wrapping test) |
- |
500 |
|
- |
| Cl- 13.9(Aluminium wires- d.c. resistance test) |
- |
2000 |
|
- |
| Cl- 13.11(Aluminium wires Procedure qualification test on welded joint of aluminium strands) |
- |
500 |
|
- |
| Cl- 13.4(Steel wires- Measurement of diameter) |
- |
500 |
|
- |
| Cl- 13.6(Steel wires- Breaking load test) |
- |
1000 |
|
- |
| Cl- 13.7(Steel wires- Ductility test) |
- |
1000 |
|
- |
| Cl- 13.8(Steel wires- Wrapping test) |
- |
1000 |
|
- |
| Cl- 13.10(Steel wires- Galvanizing test) |
- |
3000 |
|
- |
| Cl-13.7.1(Torsion Test) |
- |
500 |
|
- |
| Cl-13.7.2(Elongation Test) |
- |
500 |
|
- |
| Cl-11.1(Standard Length) |
- |
500 |
|
- |
| Cl-11.2(Random Lengths) |
- |
500 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f 09.10.2025
Exclusion: Cl- 13.15 (Conductor- Corona test (for conductors intended for use at 400 kV and above voltage level for a.c. and ± 320 kV and above voltage level for d.c.)), Cl-13.16 (Conductor- Radio interference voltage test) |
| 3656 |
IEC TEST LABS LLP
| 8165726
| IS 398 : Part 2 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
- |
140000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires Before Stranding) |
- |
1000 |
|
Rs. 20000/- [Up to 100 Sq.mm],
Rs. 110000/- [150 & 200 Sq.mm]
Rs. 120000/- [400 & 560 Sq.mm]
Rs. 140000/- [420 & 520 Sq.mm] |
| 8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires After Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires After Stranding) |
- |
1000 |
|
- |
| 10 (elec)(Stranding) |
- |
1000 |
|
- |
| 10 (elec)(Stranding) |
- |
1000 |
|
- |
| 10 (elec)(Stranding) |
- |
1000 |
|
- |
| 10 (mech)(Stranding) |
- |
1000 |
|
- |
| 13.3 Table 1 (mech)(Breaking Load of Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
| 13.3 Table 2 (mech)(Breaking Load of Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 13.3 Table 1 (mech)(Breaking Load of Aluminium Wires After Stranding) |
- |
1000 |
|
- |
| 13.3 Table 2 (mech)(Breaking Load of Steel Wires After Stranding) |
- |
1000 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
1000 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
1000 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
1000 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
1000 |
|
- |
| 13.4.2 (elec)(Ductility by Elongation Test before stranding) |
- |
1000 |
|
- |
| 13.4.2 (elec)(Ductility by Elongation Test after stranding) |
- |
1000 |
|
- |
| 13.5.1 (mech)(Wrapping Test Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
| 13.5.1 (mech)(Wrapping Test Aluminium Wires After Stranding) |
- |
1000 |
|
- |
| 13.5.2 (mech)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 13.5.2 (mech)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
1000 |
|
- |
| 13.6 (elec)(Resistance test-Aluminium wire before Stranding) |
- |
1000 |
|
- |
| 13.6 (elec)(Resistance test-Aluminium wire after stranding) |
- |
1000 |
|
- |
| 13.7.2 (chem)(Mass of Zinc coating) |
- |
1000 |
|
- |
| 13.7.2 (chem)(Uniformity of Zinc coating) |
- |
1000 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Outermost Layer) |
- |
1000 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
1000 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
1000 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
1000 |
|
- |
| 13.9 (elec)(Surface condition test) |
- |
20000 |
|
- |
| 13.10 (elec)(Ultimate breaking load) |
- |
20000 |
|
- |
| 13.11 (elec)(Stress-strain test) |
- |
80000 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
1000 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
1000 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
1000 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
1000 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Aluminium Wire Outermost Layer) |
- |
1000 |
|
- |
| 13.7.2 (elec)(Uniformity of Zinc coating) |
- |
1000 |
|
- |
| 13.7.2 (elec)(Mass of Zinc coating) |
- |
1000 |
|
- |
| 13.5.2 (elec)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
1000 |
|
- |
| 13.5.2 (elec)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 13.5.1 (elec)(Wrapping Test Aluminium Wires After Stranding) |
- |
1000 |
|
- |
| 13.5.1 (elec)(Wrapping Test Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test after stranding) |
- |
1000 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test after stranding) |
- |
1000 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test after stranding) |
- |
1000 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test after stranding) |
- |
1000 |
|
- |
| 13.3 Table 2 (elec)(Breaking Load of Steel Wires After Stranding) |
- |
1000 |
|
- |
| 13.3 Table 1 (elec)(Breaking Load of Steel Wires After Stranding) |
- |
1000 |
|
- |
| 13.3 Table 2 (elec)(Breaking Load of Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 13.3 Table 1 (elec)(Breaking Load of Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table-1 (elec)(Diameter of Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table 2 (elec)(Diameter of Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table-1 (elec)(Diameter of Aluminium Wires After Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table 2 (elec)(Diameter of Steel Wires After Stranding) |
- |
1000 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
1000 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
1000 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
1000 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Aluminium Wire Outermost Layer) |
- |
1000 |
|
- |
| 13.7.2 (elec)(Uniformity of Zinc coating) |
- |
1000 |
|
- |
| 13.7.2 (elec)(Mass of Zinc coating) |
- |
1000 |
|
- |
| 13.5.2 (elec)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
1000 |
|
- |
| 13.5.2 (elec)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 13.5.1 (elec)(Wrapping Test Aluminium Wires After Stranding) |
- |
1000 |
|
- |
| 13.5.1 (elec)(Wrapping Test Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test after stranding) |
- |
1000 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test after stranding) |
- |
1000 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test before stranding) |
- |
1000 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test before stranding) |
- |
1000 |
|
- |
| 13.3 Table 2 (elec)(Breaking Load of Steel Wires After Stranding) |
- |
1000 |
|
- |
| 13.3 Table 1 (elec)(Breaking Load of Aluminium Wires After Stranding) |
- |
1000 |
|
- |
| 13.3 Table 2 (elec)(Breaking Load of Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 13.3 Table 1 (elec)(Breaking Load of Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
| 10 (elec)(Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table 2 (elec)(Diameter of Steel Wires After Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table-1 (elec)(Diameter of Aluminium Wires After Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table 2 (elec)(Diameter of Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table-1 (elec)(Diameter of Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
| 4.1(Resistivity) |
- |
2000 |
|
- |
| 4.2(Density) |
- |
2000 |
|
- |
| 4.3(Constant-Mass Temperature Coefficient of Resistance) |
- |
2000 |
|
- |
| 4.4(Coefficient of Linear Expansion) |
- |
2000 |
|
- |
| 5.1(Density) |
- |
2000 |
|
- |
| 5.2(Coefficient of Linear Expansion) |
- |
2000 |
|
- |
| 14.2(a), 8.2.1(Sizes) |
- |
2000 |
|
- |
| 7(FREEDOM FROM DEFECTS) |
- |
2000 |
|
- |
| 6.2(zinc Purity) |
- |
2000 |
|
- |
| 9(Joint in wires) |
- |
2000 |
|
- |
| 6.1.1(Aluminum wires shall conform to IS 5484) |
- |
2000 |
|
- |
| 6.1.2(The mechanical properties of wire
shall comply with the requirements given in Table 2) |
- |
1000 |
|
- |
| 6.2(It shall conform to and satisfy all the requirements
of IS 209) |
- |
1000 |
|
- |
| 8.2.2(Calculated resistance) |
- |
1000 |
|
- |
| Cl-9.2.5(Welded joint strength) |
- |
2000 |
|
- |
|
07 Sep, 2026 |
- - |
| 3657 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 16440 (2016) |
Stainless steel milk cans - Specification |
All Size as per IS |
32500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2(Carbon) |
- |
12500 |
|
- |
| 5.2(Sulphur) |
- |
12500 |
|
- |
| 5.2(phosphorus) |
- |
12500 |
|
- |
| 5.2(Manganese) |
- |
12500 |
|
- |
| 5.2(Silicon) |
- |
12500 |
|
- |
| 5.2(Chromium) |
- |
12500 |
|
- |
| 5.2(Nickel) |
- |
12500 |
|
- |
| 5.2(molybdenum) |
- |
12500 |
|
- |
| 3.0(Capacity test) |
- |
10000 |
|
- |
| 6.3(Hardness test) |
- |
10000 |
|
- |
| 6.1(Pressure check for leakage and bulging) |
- |
10000 |
|
- |
| 6.2(Drop test) |
- |
10000 |
|
- |
| 6.4(Dye penetration test) |
- |
10000 |
|
- |
| "As per Clause 4 & Table 1"(Shape & Dimensions) |
- |
10000 |
|
- |
| As per Clause 5.4(Thickness of parts) |
- |
10000 |
|
- |
| As per Clause 5.5(Mass of can (Weight)) |
- |
10000 |
|
- |
| As per Clause 5.6(Construction) |
- |
10000 |
|
- |
| Clause 5.6.1(Body) |
- |
10000 |
|
- |
| As per Clause 5.6.2(Handle) |
- |
10000 |
|
- |
| Clause 5.6.3(Bottom ring) |
- |
10000 |
|
- |
| Clause 5.6.4(Lid) |
- |
10000 |
|
- |
| Clause 5.6.6(Finish) |
- |
10000 |
|
- |
| Clause 5.6.7(Heat treatment and Passivation) |
- |
0 |
|
- |
| Clause 6.5(Leakage test) |
- |
10000 |
|
- |
| Clause 4 & Table 1"(Shape & Dimensions) |
- |
10000 |
|
- |
| Clause 5.4(Thickness of parts) |
- |
10000 |
|
- |
| Clause 5.5(Mass of can (Weight)) |
- |
10000 |
|
- |
| Clause 5.6(Construction) |
- |
10000 |
|
- |
| Clause 5.6.1(Body) |
- |
10000 |
|
- |
| Clause 5.6.2(Handle) |
- |
10000 |
|
- |
| Clause 5.6.3(Bottom ring) |
- |
10000 |
|
- |
| Clause 5.6.6(Finish) |
- |
10000 |
|
- |
| Clause 5.6.7(Heat treatment and Passivation) |
- |
0 |
|
- |
| Clause 6.5(Leakage test) |
- |
10000 |
|
- |
| 5.2(Carbon) |
- |
0 |
|
- |
| 5.2(Sulphur) |
- |
0 |
|
- |
| 5.2(phosphorus) |
- |
0 |
|
- |
| 5.2(Manganese) |
- |
0 |
|
- |
| 5.2(Silicon) |
- |
0 |
|
- |
| 5.2(Chromium) |
- |
0 |
|
- |
| 5.2(Nickel) |
- |
0 |
|
- |
| 5.2(molybdenum) |
- |
0 |
|
- |
| 3.0(Capacity test) |
- |
0 |
|
- |
| 6.3(Hardness test) |
- |
0 |
|
- |
| 6.1(Pressure check for leakage and bulging) |
- |
0 |
|
- |
| 6.2(Drop test) |
- |
0 |
|
- |
| 6.4(Dye penetration test) |
- |
0 |
|
- |
| "As per Clause 4 & Table 1"(Shape & Dimensions) |
- |
0 |
|
- |
| As per Clause 5.4(Thickness of parts) |
- |
0 |
|
- |
| As per Clause 5.5(Mass of can (Weight)) |
- |
0 |
|
- |
| As per Clause 5.6(Construction) |
- |
0 |
|
- |
| Clause 5.6.1(Body) |
- |
0 |
|
- |
| As per Clause 5.6.2(Handle) |
- |
0 |
|
- |
| Clause 5.6.3(Bottom ring) |
- |
0 |
|
- |
| Clause 5.6.4(Lid) |
- |
0 |
|
- |
| Clause 5.6.6(Finish) |
- |
0 |
|
- |
| Clause 5.6.7(Heat treatment and Passivation) |
- |
0 |
|
- |
| Clause 6.5(Leakage test) |
- |
0 |
|
- |
| Clause 4 & Table 1"(Shape & Dimensions) |
- |
0 |
|
- |
| Clause 5.4(Thickness of parts) |
- |
0 |
|
- |
| Clause 5.5(Mass of can (Weight)) |
- |
0 |
|
- |
| Clause 5.6(Construction) |
- |
0 |
|
- |
| Clause 5.6.1(Body) |
- |
0 |
|
- |
| Clause 5.6.2(Handle) |
- |
0 |
|
- |
| Clause 5.6.3(Bottom ring) |
- |
0 |
|
- |
| Clause 5.6.6(Finish) |
- |
0 |
|
- |
| Clause 5.6.7(Heat treatment and Passivation) |
- |
0 |
|
- |
| Clause 6.5(Leakage test) |
- |
0 |
|
- |
|
- |
- Included w.e.f 30.01.2026 |
| 3658 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 15905 (2024) |
Hubless Centrifugally Cast (Spun) Iron Pipes, Fittings and Accessories — Spigot Series —Specification |
For all sizes except for the tests mentioned in remarks |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-10.2 (External Diameters and Tolerances) |
- |
|
|
|
| Cl-10.3 (Thickness and Tolerances) |
- |
|
|
|
| Cl-10.5 (Tolerances on Angles) |
- |
|
|
|
| Cl-10.6 (Straightness of Pipe) |
- |
|
|
|
| 7 ("VISUAL INSPECTION AND HAMMER
TEST") |
- |
|
|
|
| 6 (JOINTS) |
- |
|
|
|
| 11 (COATING) |
- |
|
|
|
|
- |
- Mech: Except 8 (crushing Test), 9 (Hydrostatic Test), 11.2 (resistance to salt spray) |
| 3659 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 302 : Part 2 : Sec 14 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision) |
- |
65000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
500 |
|
Additional Testing Charge For EMI/EMC:- 20,0000/- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.101(Marking) |
- |
0 |
|
- |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
5000 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
5000 |
|
- |
| 11(Heating, IS 302-1) |
- |
10000 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
2500 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
2500 |
|
- |
| 14(Transient Over Voltages, IS 302-1) |
- |
5000 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
5000 |
|
- |
| 15.2(Moisture Resistance, IS 302-1) |
- |
5000 |
|
- |
| 15(Moisture Resistance, IS 302-1) |
- |
2500 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
2500 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
5000 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
0 |
|
- |
| 19.7(Abnormal Operation, IS 302-1) |
- |
5000 |
|
- |
| 19.8(Abnormal Operation, IS 302-1) |
- |
2500 |
|
- |
| 19.9(Abnormal Operation, IS 302-1) |
- |
2500 |
|
- |
| 19.1(Abnormal Operation, IS 302-1) |
- |
2500 |
|
- |
| 19.101(Abnormal Operation) |
- |
2500 |
|
- |
| 19.102(Abnormal Operation) |
- |
2500 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
2500 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
- |
| 20.101(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.102(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.103(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.104(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.105(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.106(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.107(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.108(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.109(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.110(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.111(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.112(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.113(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.114(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.115(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.116(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
2500 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
2500 |
|
- |
| 22(Construction, IS 302-1) |
- |
5000 |
|
- |
| 22.101(Construction) |
- |
500 |
|
- |
| 22.102(Construction) |
- |
500 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
5000 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.10(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 24.1(Components, IS 302-1) |
- |
500 |
|
- |
| 24.2(Components, IS 302-1) |
- |
500 |
|
- |
| 24.5(Components, IS 302-1) |
- |
500 |
|
- |
| 24.6(Components, IS 302-1) |
- |
500 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
5000 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
5000 |
|
- |
| 27(Provision for Earthing, IS 302-1) |
- |
5000 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
5000 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
5000 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
5000 |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
2500 |
|
- |
| 32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
2500 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
25000 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
45000 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
25000 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
25000 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
30000 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
25000 |
|
- |
| 19.11.4.7(Harmonics) |
- |
25000 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 4(GENERAL REQUIREMENTS) |
- |
500 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
500 |
|
- |
| 27(Provision for Earthing) |
- |
500 |
|
- |
| 29(Clearances, Creepage distances and Solid Insulation) |
- |
500 |
|
- |
|
- |
- Included w.e.f. 18.08.2025 |
| 3660 |
UL India Private limited, Gurgaon
| 8127226
| IS 302 : Part 1 (2024) |
Household and Similar Electrical Appliances â Safety Part 1 General Requirements (Seventh Revision) |
Household and Similar Electrical Appliances |
95000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
1500 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
3000 |
|
Testing Charges of complete Cl. No. 8, IS 302-1:2024 |
| 8.1.2(Protection against live parts in openings) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 8) |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 8) |
| 8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 8) |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 8) |
| 10.1(Power input) |
- |
8000 |
|
Testing Charges of complete Cl. No. 10, IS 302-1:2024 |
| 10.2(Current input) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 10) |
| 11.1(General) |
- |
10000 |
|
Testing Charges of complete Cl. No. 11, IS 302-1:2024 |
| 11.2(General) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.3(Heating) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.4(Heating appliances) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.5(Motor-operated appliances) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.6(Combined appliances) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.7(Duration corresponding) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.8(Temperature rise) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 12(Charging of metal-ion batteries) |
- |
2000 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
5000 |
|
Testing Charges of complete Cl. No. 13, IS 302-1:2024 |
| 13.2(Leakage current at operating temperature) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 13) |
| 13.3(Electric Strength at operating temperature) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 13) |
| 14(Transient Over Voltages) |
- |
8000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
8000 |
|
Testing Charges of complete Cl. No. 15, IS 302-1:2024 |
| 15.3(Humidity Test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 15) |
| 15.0(Moisture resistance) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 15) |
| 16(Leakage current and electric strength) |
- |
5000 |
|
Testing Charges of complete Cl. No. 16, IS 302-1:2024 |
| 17(Overload protection of transformers and associated circuits) |
- |
5000 |
|
Testing Charges of complete Cl. No. 17, IS 302-1:2024 |
| 19(Abnormal Operation) |
- |
8000 |
|
Testing Charges of complete Cl. No. 19, IS 302-1:2024 |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
3000 |
|
Testing Charges of complete Cl. No. 20, IS 302-1:2024 |
| 21.1(Mechanical Strength, IS 302-1) |
- |
6000 |
|
Testing Charges of complete Cl. No. 21, IS 302-1:2024 |
| 22.1(Construction, IS 302-1) |
- |
6000 |
|
Testing Charges of complete Cl. No. 22, IS 302-1:2024 |
| 23.1(Internal Wiring, IS 302-1) |
- |
1000 |
|
Testing Charges of complete Cl. No. 23, IS 302-1:2024 |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
Testing Charges of complete Cl. No. 25, IS 302-1:2024 |
| 26(Terminals for external conductors) |
- |
1000 |
|
Testing Charges of complete Cl. No. 26, IS 302-1:2024 |
| 27.1(Provision for Earthing, IS 302-1) |
- |
1500 |
|
Testing Charges of complete Cl. No. 27, IS 302-1:2024 |
| 28(Screw test and connections) |
- |
1500 |
|
Testing Charges of complete Cl. No. 28, IS 302-1:2024 |
| 29(clearance, creepage distances and solid insulation) |
- |
2500 |
|
Testing Charges of complete Cl. No. 29, IS 302-1:2024 |
| 30.1(Ball pressure test) |
- |
6000 |
|
Testing Charges of complete Cl. No. 30, IS 302-1:2024 |
| 30.2(Glow Wire Test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 30) |
| 30.2(Needle Flame Test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 30) |
| 31(Resistance to Rusting) |
- |
2000 |
|
Testing Charges of complete Cl. No. 31, IS 302-1:2024 |
| 5(General conditions for the tests) |
- |
0 |
|
Not Applicable |
| 6(Classification- IS 302-1) |
- |
0 |
|
Not Applicable |
| 4(General requirement) |
- |
0 |
|
Not Applicable |
| 15.2(Spillage Test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 15) |
| 16.0(General) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 16) |
| 16.1(General) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 16) |
| 16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 16) |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 16) |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 19) |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 19) |
| 19.11.4.7(Harmonics) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 19) |
| 19.17(Abnormal Operation, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 19) |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 20) |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 21) |
| 21.3(Mechanical Strength, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 21) |
| 22.5(Construction) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 22.6(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 22.11(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 22.16(Construction) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 22.42(Construction) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 23) |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 25) |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 25) |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 25) |
| 26.5(Terminals for external conductors) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 26) |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 27) |
| 28.1(Screws and connections) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 28) |
| A.2(Earth continuity test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 27) |
| 22.2(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 12) |
| 22.3(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 12) |
| B.22.4(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 12) |
| B.22.5(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 12) |
| Annex C(Ageing test on motors) |
- |
0 |
|
Not Applicable |
| Annex D(Thermal motor protectors) |
- |
0 |
|
Not Applicable |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 25) |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 17) |
| 15.2(Moisture resistance) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 15) |
| 7(Marking and instructions) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 7) |
| 8.1.1(Protection against live parts in all positions) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 8) |
| 8.1.2(Protection against live parts in openings) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 8) |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 8) |
| 8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 8) |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 8) |
| 10.1(Power input) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 10) |
| 10.2(Current input) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 10) |
| 11.1(General) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.2(General) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.3(Heating) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.4(Heating appliances) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.5(Motor-operated appliances) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.6(Combined appliances) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.7(Duration corresponding) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.8(Temperature rise) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 12(Charging of metal-ion batteries) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 12) |
| 13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 13) |
| 13.2(Leakage current at operating temperature) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 13) |
| 13.3(Electric Strength at operating temperature) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 13) |
| 14(Transient Over Voltages) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 14) |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 15) |
| 15.3(Humidity Test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 15) |
| 15.0(Moisture resistance) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 15) |
| 16(Leakage current and electric strength) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 16) |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 17) |
| 19(Abnormal Operation) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 19) |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 20) |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 21) |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 23) |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 25) |
| 26(Terminals for external conductors) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 26) |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 27) |
| 28(Screw test and connections) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 28) |
| 29(clearance, creepage distances and solid insulation) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 29) |
| 30.1(Ball pressure test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 30) |
| 30.2(Glow Wire Test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 30) |
| 30.2(Needle Flame Test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 30) |
| 31(Resistance to Rusting) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 31) |
| 5(General conditions for the tests) |
- |
0 |
|
Not Applicable |
| 6(Classification- IS 302-1) |
- |
0 |
|
Not Applicable |
| 4(General requirement) |
- |
0 |
|
Not Applicable |
| 15.2(Spillage Test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 15) |
| 16.0(General) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 16) |
| 16.1(General) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 16) |
| 16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 16) |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 16) |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 19) |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 19) |
| 19.11.4.7(Harmonics) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 19) |
| 19.17(Abnormal Operation, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 19) |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 20) |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 21) |
| 21.3(Mechanical Strength, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 21) |
| 22.5(Construction) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 22.6(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 22.11(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 22.16(Construction) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 22.42(Construction) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 23) |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 25) |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 25) |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 25) |
| 26.5(Terminals for external conductors) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 26) |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 27) |
| 28.1(Screws and connections) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 28) |
| A.2(Earth continuity test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 27) |
| 22.2(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 12) |
| 22.3(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 12) |
| B.22.4(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 12) |
| B.22.5(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 12) |
| Annex C(Ageing test on motors) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| Annex D(Thermal motor protectors) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 25) |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
Not Applicable Not Applicable (Testing charges as per complete Cl. 17) |
| 15.2(Moisture resistance) |
- |
0 |
|
Not Applicable Not Applicable (Testing charges as per complete Cl. 15) |
|
- |
view Scope file Included w.e.f.21.08.2025
Exclusion
Cl 19.11.4.1 to Cl 19.11.4.7 EMI/EMC
"Domestic Electric Clothes Washing Machines
(For testing charges please refer part 2 standard in LIMS)" |