| 451 |
National Test House (NWR) - NTH, Jaipur
| 8122904
| IS 15477 (2019) |
Adhesives for use with ceramic tiles and mosaics |
Type-I, II, III, IV, V |
21000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Classification) |
- |
1000 |
|
- |
| 5.1(Tensile Adhesion Strength ) |
- |
2500 |
|
- |
| 5.1(Tensile Adhesion Strength) |
- |
2500 |
|
- |
| 5.2(Shear Adhesion Strength ) |
- |
3000 |
|
- |
| 5.2(Shear Adhesion Strength) |
- |
3000 |
|
- |
| 5.2(Shear Adhesion Strength) |
- |
3000 |
|
- |
| 5.3(OpenTime) |
- |
1000 |
|
- |
| 5.4(Adjustment Time) |
- |
1000 |
|
- |
| 5.5(Slip (Required for Vertical Application Only)) |
- |
3000 |
|
- |
| 5.6(Deformability (Required for VerticalApplication Only)) |
- |
3000 |
|
- |
|
31 Dec, 2026 |
- - |
| 452 |
National Test House (NWR) - NTH, Jaipur
| 8122904
| IS 1659 (2004) |
Block boards - Specification (Fourth Revision) |
BWP-DEC, BWP-COM, MR-DEC, MR-COM |
11000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1.3, 6.3.3, IS 303(Visual Inspection - Permissible Defects - IS 303 [test method for COMMERCIAL type]) |
- |
500 |
|
- |
| 8.1.3, 6.3.3, IS 1328(Visual Inspection - Permissible Defects - IS 1328 [test method for DECORATIVE type]) |
- |
500 |
|
- |
| 7.3(Dimensional Requirements - Length - 8.1.4) |
- |
100 |
|
- |
| 7.3(Dimensional Requirements - Width - 8.1.4) |
- |
100 |
|
- |
| 7.3(Dimensional Requirements - Thickness - Annexure E) |
- |
100 |
|
- |
| 7.3(Dimensional Requirements - Edge Straightness - Annexure D) |
- |
100 |
|
- |
| 7.3(Dimensional Requirements - Squareness - Annexure D) |
- |
100 |
|
- |
| 7.3(Dimensional Requirements - Variation in thickness - Annexure E) |
- |
0 |
|
- |
| 9.2.1(Dimensional Changes caused by humidity - Change in Length - at 90% RH - Annexure F) |
- |
500 |
|
- |
| 9.2.1(Dimensional Changes caused by humidity - Change in Length - at 40% RH - Annexure F) |
- |
500 |
|
- |
| 9.2.1(Dimensional Changes caused by humidity - Change in Thickness - at 90% RH - Annexure F) |
- |
0 |
|
- |
| 9.2.1(Dimensional Changes caused by humidity - Change in thickness - at 40% RH - Annexure F) |
- |
0 |
|
- |
| 9.2.1(Dimensional Changes caused by humidity - Delamination - Annexure F) |
- |
0 |
|
- |
| 9.2.1(Dimensional Changes caused by humidity Change in local planeness - Annexure F) |
- |
0 |
|
- |
| 9.2.2 (Resistance to water - Annexure G, Annexure H [For BWP grade]) |
- |
2000 |
|
- |
| 9.2.2 (Resistance to water - Annexure G, Annexure H [For MR Grade]) |
- |
2000 |
|
- |
| 9.2.3(Adhesion of Plies - Annexure H) |
- |
0 |
|
- |
| 9.2.4(Mycological Test [for MR grade only] - Annexure J) |
- |
2000 |
|
- |
| 9.2.5(Modulus of rupture - AVERAGE - Annexure K) |
- |
1000 |
|
- |
| 9.2.5(Modulus of rupture - MINIMUM INDIVIDUAL - Annexure K) |
- |
0 |
|
- |
| 9.2.5(Modulus of elasticity - AVERAGE - Annexure K) |
- |
1000 |
|
- |
| 9.2.5(Modulus of elasticity - MINIMUM INDIVIDUAL - Annexure K) |
- |
0 |
|
- |
| 9.2.6(Spot test - Annexure L) |
- |
2000 |
|
- |
|
31 Dec, 2026 |
- - |
| 453 |
National Test House (NWR) - NTH, Jaipur
| 8122904
| IS 3812 (Part 1) (2013) |
Pulverized fuel ash - Specification: Part 1 For use as pozzolana in cement, cement mortar and concrete |
Siliceous/ Calcareous |
13500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1-Table 2(ii)(PHYSICAL REQUIREMENTS-Particles retained on 45 micron IS sieve) |
- |
2000 |
|
-- |
| 7.1-Table 2(v)(PHYSICAL REQUIREMENTS-Soundness by autoclave test ) |
- |
2000 |
|
-- |
| 7.1-Table 2(iv)(PHYSICAL REQUIREMENTS-Compressive strength at 28 days) |
- |
3000 |
|
-- |
| 7.1-Table 2(i)(PHYSICAL REQUIREMENTS-Fineness) |
- |
1000 |
|
-- |
| Cl. 6.1, Table 1 - i(Silicon dioxide (SiO2) plus aluminium oxide (Al2O3) plus ironoxide (Fe2O3) - IS 1727) |
- |
500 |
|
- |
| Cl. 6.1, Table 1 - ii(Silicon dioxide (SiO2) - IS 1727) |
- |
500 |
|
- |
| Cl. 6.1, Table 1 - iii(Reactive Silica - Annex B) |
- |
500 |
|
- |
| Cl. 6.1, Table 1 - iv(Magnesium oxide (MgO) - IS 1727) |
- |
500 |
|
- |
| Cl. 6.1, Table 1 - v( Total sulphur as sulphur trioxide (SO3) - IS 1727) |
- |
500 |
|
- |
| Cl. 6.1, Table 1 - vi( Available alkalis as equivalent sodium oxide (Na2O) - Annex C) |
- |
2000 |
|
- |
| Cl. 6.1, Table 1 - vii( Total Chlorides - IS 4032) |
- |
500 |
|
- |
| Cl. 6.1, Table 1 - viii( Loss on ignition - IS 1727) |
- |
500 |
|
- |
| Cl. 6.2(Moisture content of the fly ash when supplied in dry condition - Annex D) |
- |
500 |
|
- |
| 5.1, 7.1, table-2, iii(Lime reacitivity) |
- |
2500 |
|
- |
|
31 Dec, 2026 |
- - |
| 454 |
National Test House (WR) - NTH, Mumbai
| 7107604
| IS 2645 (2003) |
Integral waterproofing compounds for cement mortar and concrete - Specification (Second Revision) |
- |
9000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 3.2(Initial setting time of cement) |
- |
500 |
|
- |
| Clause 3.2(Final setting time of cement) |
- |
500 |
|
- |
| Cl 3.3(Compressive Strength, At 3days & 7 days) |
- |
4000 |
|
- |
| Clause 3.1
(Permeability to water of cement mortar) |
- |
3000 |
|
- |
| Clause 3.4(Chloride content) |
- |
1000 |
|
- |
|
- |
- - |
| 455 |
National Test House (WR) - NTH, Mumbai
| 7107604
| IS 3812 : Part 2 (2013) |
Pulverized Fuel Ash - Part 2 : For Use as Admixture in Cement Mortar and Concrete |
- |
8000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1, Table 1(Fineness — Specific surface in m2 /kg) |
- |
1000 |
|
Full |
| 7.1, Table 1(Particles retained on 45 micron IS sieve (wet sieving)) |
- |
500 |
|
Full |
| 7.1, Table 1(Soundnes) |
- |
1000 |
|
Full |
|
- |
- - |
| 456 |
National Test House (NWR) - NTH, Jaipur
| 8122904
| IS 2202 : Part 1 (1999) |
Wooden flush door shutters (Solid Core Type) - Specification: Part 1 plywood face panels (Sixth Revision) |
- |
18000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 11.15(Screw Withdrawal Strength - IS 4020 (Pt-16)) |
- |
1000 |
|
- |
| 11.15(Screw Withdrawal Resistance test - IS 4020 (Pt-16)) |
- |
0 |
|
- |
| 11.14(Glue Adhesion Test - IS 4020(Pt-15)) |
- |
1000 |
|
- |
| 11.13(Knife Test - IS 4020(Pt-14)) |
- |
1000 |
|
- |
| 11.12(End Immersion Test - IS 4020(Pt-13)) |
- |
1000 |
|
- |
| 11.11(Maximum departure from the general planeness - IS 4020(Pt-12)) |
- |
1000 |
|
- |
| 11.11(The recovery of the original size after subjecting the door to high and low humidity- IS 4020(Pt-12)) |
- |
3000 |
|
- |
| 11.1(Misuse Test - IS 4020(Pt-11)) |
- |
1000 |
|
- |
| 11.9(Slamming Test - IS 4020(Pt-10)) |
- |
1000 |
|
- |
| 11.8(Residual deformation after 15 minutes of unloading - IS 4020(Pt-9)) |
- |
1500 |
|
- |
| 11.8(Initial deflection - IS 4020(Pt-9)) |
- |
0 |
|
- |
| 11.8(Buckling Test - IS 4020(Pt-9)) |
- |
0 |
|
- |
| 11.7(Shock Resistance Test -IS 4020(Pt-8)) |
- |
1500 |
|
- |
| 11.7(Shock Resistance Test -IS 4020(Pt-8)) |
- |
0 |
|
- |
| 11.6(Residual lateral buckling - IS 4020(Pt-7)) |
- |
1500 |
|
- |
| 11.6(Lateral buckling during loading - IS 4020(Pt-7)) |
- |
0 |
|
- |
| 11.6(Residual deflection after removal of load - IS 4020(Pt-7)) |
- |
0 |
|
- |
| 11.6(Deflection of the edge at maximum load - IS 4020(Pt-7)) |
- |
1500 |
|
- |
| 11.5(Residual deflection - IS 4020(Pt-6)) |
- |
0 |
|
- |
| 11.5(Deflection at maximum load - IS 4020(Pt-6)) |
- |
0 |
|
- |
| 11.4(Depth of indentation - IS 4020(Pt-5)) |
- |
1000 |
|
- |
| 11.3(Depth of deviation - IS 4020(Pt-4)) |
- |
0 |
|
- |
| 11.2( Twist, cupping & wrapping - IS 4020 (Pt-3)) |
- |
1000 |
|
- |
| 11.1( Squareness Test - IS 4020 (Pt-2)) |
- |
1000 |
|
- |
| 11.1(Variation in thickness - IS 4020 (Pt-2)) |
- |
0 |
|
- |
| 11.1(Thickness - IS 4020 (Pt-2)) |
- |
1000 |
|
- |
| 11.1(Width- IS 4020 (Pt-2)) |
- |
1000 |
|
- |
| 11.1(Height - IS 4020 (Pt-2)) |
- |
1000 |
|
- |
| 9.3(Workmanship & finish - IS 2202(Pt-1)) |
- |
1000 |
|
- |
| 9.2(Workmanship & finish - IS 2202(Pt-1)) |
- |
0 |
|
- |
| 6.2(Plywood) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 457 |
National Test House (NWR) - NTH, Jaipur
| 8122904
| IS 1786 (2008) |
High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) |
415/415D/415S/500/500D/500S/550/550D/600/650/700 |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Carbon %) |
- |
500 |
|
- |
| 4.1(Sulphur %) |
- |
500 |
|
- |
| 4.1(Phosphorus %) |
- |
500 |
|
- |
| 4.1(Sulphur and phosphorous) |
- |
500 |
|
- |
| Cl. 5.3 (b)(The ribs contributing the projected area - Transverse Ribs) |
- |
1000 |
|
- |
| Cl 7.2(Weight) |
- |
1000 |
|
- |
| Cl. 8.1 Table 3(Yield Stress (YS)) |
- |
1000 |
|
- |
| Cl. 8.1 Table 3(Elongation, percentage) |
- |
1000 |
|
- |
| Cl. 8.1 Table 3(Tensile Strength (TS)) |
- |
1000 |
|
- |
| Cl. 8.1 Table 3(TS/YS ratio) |
- |
500 |
|
- |
| Cl. 9.3, Table 4(Bend Test ) |
- |
1000 |
|
- |
| Cl.9.4 & Cl. 9.4.1(Rebend test) |
- |
1000 |
|
- |
| Cl. 5.3 (a)(The ribs contributing the projected area - Longitudinal Ribs) |
- |
1000 |
|
- |
| 4.1(CE) |
- |
1000 |
|
- |
| Cl. 7.2 Table -2 (Nominal Mass) |
- |
1000 |
|
- |
| Cl. 6.1(Nominal Size) |
- |
500 |
|
- |
| Cl. 5 (Cl. 5 - Mean projected area of transverse ribs (1/3 of Ar)) |
- |
1000 |
|
- |
| Cl. 5 (Cl.5 Mean area of ribs/unit length (Ar), ) |
- |
1000 |
|
- |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 MANGANESE) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Vanadium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Molybdenum- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Chromium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Nickel- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Copper- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| 8.18.1 Table 3(Total elongation at maximum force) |
- |
500 |
|
- |
| Cl. 4.3(Visual Inspection.) |
- |
500 |
|
- |
| Clause 6.3(Effective Cross-sectional Area) |
- |
500 |
|
- |
| 13(Identification and marking) |
- |
500 |
|
- |
| 7.1(Specified length) |
- |
500 |
|
- |
| 9.5(Retest) |
- |
500 |
|
- |
| 12(Inspection) |
- |
500 |
|
- |
| 4.1( Nitrogen%) |
- |
500 |
|
- |
| 4.1( Aluminium %) |
- |
500 |
|
- |
| 4.1( Copper %) |
- |
500 |
|
- |
| 4.1(Silicon %) |
- |
500 |
|
- |
| 4.1(Manganese %) |
- |
500 |
|
- |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 SULPHUR+PHOSPHUR) |
- |
500 |
|
- |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 NITROGEN) |
- |
500 |
|
- |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 PHOSPHURS) |
- |
500 |
|
- |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 SULPHUR) |
- |
500 |
|
- |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 CARBON ) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Nitrogen- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415D,Fe 415S, Fe 500D,Fe 500S,Fe 550D)(Carbon Equivalent) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Sulphur & Phosphorous) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Phosphorous- IS 228) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Sulphur-IS 228) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Carbon-IS 228) |
- |
500 |
|
- |
| 4.2(Niobium (Nb)) |
- |
500 |
|
- |
| 4.2(Boron (B)) |
- |
500 |
|
- |
| Clause 4.2 Note 2, Amendment 1 & 3(Nb+V+B+Ti) |
- |
500 |
|
- |
| Clause 4.2 Note 3, Amendment 1 & 3(Cr+Cu+Ni+Mo+P) |
- |
500 |
|
- |
|
31 Dec, 2026 |
- - |
| 458 |
National Test House (NWR) - NTH, Jaipur
| 8122904
| IS 5522 (2014) |
Stainless steel sheets and strips for utensils - Specification (Third Revision) |
As per specification |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.2, Table 3(Tensile Test-1608:Part 1) |
- |
3000 |
|
- |
| 8.2, Table 3(Proof Stress, N/mm2) |
- |
1000 |
|
- |
| 8.2, Table 3(Tensile Strength, N/mm2) |
- |
1000 |
|
- |
| 8.3(Hardness , max-IS 1500 or IS 1501 (Part 1) or IS 1586) |
- |
1000 |
|
- |
| 8.2, Table 3(Elongation, %) |
- |
1000 |
|
- |
| 8.4(Bend Test) |
- |
1000 |
|
- |
| 8.5(Erichsen Cupping Test) |
- |
2000 |
|
- |
| 10.1(Thickness, mm) |
- |
500 |
|
- |
| 10.2(width, mm) |
- |
500 |
|
- |
| 10.3(Length, mm) |
- |
500 |
|
- |
| 10.4(Flatness,mm) |
- |
500 |
|
- |
| 10.5(Camber, mm) |
- |
500 |
|
- |
| 11(Surface Finish) |
- |
500 |
|
- |
| Cl . 6 .0(Freedom from defect) |
- |
1000 |
|
- |
| 13(Marking) |
- |
0 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
700 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
700 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
700 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
400 |
|
- |
|
31 Dec, 2026 |
- - |
| 459 |
National Test House (NWR) - NTH, Jaipur
| 8122904
| IS 15997 (2012) |
Low nickel austenitic stainless steel sheet and strip for utensils and kitchen appliances - Specification |
As per specification |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Freedom From Defects) |
- |
500 |
|
- |
| 9.3(Tensile Test-1608:Part 1) |
- |
1000 |
|
- |
| 9.3, Table 3 (Yield Strength, Mpa) |
- |
1000 |
|
- |
| 9.3, Table 3 (Tensile Strength, Mpa) |
- |
1000 |
|
- |
| 9.3, Table 3 (Elongation, %) |
- |
1000 |
|
- |
| 9.4(Erichsen Cupping Test,(Average depth of cupping) mm) |
- |
2000 |
|
- |
| 11(Surface finish) |
- |
500 |
|
- |
| 12(Dimensions) |
- |
1000 |
|
- |
| 14.1(Thickness,mm) |
- |
500 |
|
- |
| 14.2( Width, mm) |
- |
500 |
|
- |
| 14.3(Length, mm) |
- |
500 |
|
- |
| 17(Marking) |
- |
500 |
|
- |
| 14.4(Flatness, mm) |
- |
1000 |
|
- |
| 14.5(Camber, mm) |
- |
1000 |
|
- |
| Clause 9.1, 9.2 & Table 3(IS 1608 Part 1) |
- |
1000 |
|
- |
| 17(Marking) |
- |
500 |
|
- |
| Clause 9.1, 9.2 & Table 3(0.2 Percent Yield Strength) |
- |
1000 |
|
- |
| 4.1(General requirements) |
- |
1000 |
|
- |
| 6(Freedom from defects) |
- |
1000 |
|
- |
| 7(Heat treatment) |
- |
1000 |
|
- |
| 8.1, table 1(C
Si
Mn
Ni
Cr
S
P
Cu
Ni) |
- |
4000 |
|
- |
| 9.1(Sample plan) |
- |
500 |
|
- |
| 9.2(Tensile test) |
- |
3000 |
|
- |
| 9.3(Mechanical properties) |
- |
3000 |
|
- |
| 9.4(Erichsen cupping test) |
- |
2000 |
|
- |
| 10(Retests) |
- |
0 |
|
- |
| 11(Surface finish) |
- |
1000 |
|
- |
| 12(Dimensions) |
- |
1000 |
|
- |
| 13(Edge condition) |
- |
500 |
|
- |
| 14.1(Thickness) |
- |
1000 |
|
- |
| 14.2.1(Mill Edge) |
- |
500 |
|
- |
| 14.2.2(Trimmed Edge) |
- |
500 |
|
- |
| 14.3(Length) |
- |
1000 |
|
- |
| 14.4(Flatness) |
- |
1000 |
|
- |
| 14.5(Camber) |
- |
1000 |
|
- |
| 15(Inspection) |
- |
0 |
|
- |
| 8.1.1, table 2(Carbon
Silicon
Manganese
Nickel
Chromium
Sulphur
Phosphorus
Copper
Nitrogen) |
- |
4000 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Copper -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
- |
|
31 Dec, 2026 |
- - |
| 460 |
National Test House (NWR) - NTH, Jaipur
| 8122904
| IS 398 : Part 6 (2021) |
Aluminium Conductors For Overhead Transmission Purposes Part 6: High conductivity aluminium alloy stranded conductors |
- |
80000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 16.2(Visual Examination) |
- |
1000 |
|
- |
| 16.3, Table 4(Measurement of Lay Ratio / Direction of Lay) |
- |
1000 |
|
- |
| 16.3, Table 4(Measurement of Lay Ratio / Direction of Lay) |
- |
1000 |
|
- |
| 16.3, Table 4(Measurement of Lay Ratio / Direction of Lay) |
- |
1000 |
|
- |
| 16.3, Table 4(Measurement of Lay Ratio / Direction of Lay) |
- |
1000 |
|
- |
| 16.4, Table 2(Measurement of Diameter of Individual Aluminium Alloy Wires) |
- |
1000 |
|
- |
| 16.5, Table 2(Breaking Load Test - before stranding) |
- |
3000 |
|
- |
| 16.5, Table 2(Breaking Load Test - after stranding) |
- |
3000 |
|
- |
| 16.6, Table 1(Elongation Test - before stranding) |
- |
1000 |
|
- |
| 16.6, Table 1(Elongation Test - after stranding) |
- |
1000 |
|
- |
| 16.7, Table 2(Resistivity Test) |
- |
3000 |
|
- |
| 16.8(Wrapping Test) |
- |
1000 |
|
- |
| 11(Stranding) |
- |
1000 |
|
- |
| 8(Freedom from defects) |
- |
1000 |
|
- |
| 16.9, Table 3(Ultimate Tensile Strength on Stranded Conductor) |
- |
7000 |
|
- |
| 16.11(Stress-strain Test) |
- |
50000 |
|
- |
| 16.10, Table 3(d.c. Resistance Test on Stranded Conductor) |
- |
3000 |
|
- |
|
31 Dec, 2026 |
- - |
| 461 |
National Test House (NWR) - NTH, Jaipur
| 8122904
| IS 1161 (2014) |
Steel tubes for structural purposes - Specification (Fifth Revision) |
As per IS |
9000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 6(Outer Diameter, Thickness & Mass) |
- |
500 |
|
- |
| Cl 11(Tensile Test, Flattening Test & Cold Bend Test) |
- |
500 |
|
- |
| Clause - 5.1, Table-3( CARBON) |
- |
500 |
|
- |
| Clause - 5.1, Table-3(SULPHUR) |
- |
500 |
|
- |
| Clause - 5.1, Table-3(PHOSPHURS) |
- |
500 |
|
- |
| 8 AND AS PER IS 4736(UNIFORMITY OF ZINC COATING) |
- |
1000 |
|
- |
| 8 AND AS PER IS 4736(MASS OF ZINC COATING) |
- |
1000 |
|
- |
| Cl 7(Workmanship) |
- |
500 |
|
- |
| 9(Straightness) |
- |
1000 |
|
- |
| 10(Lengths) |
- |
500 |
|
- |
| 5 AND AS PER IS 10748(CARBON EQUIVALENT) |
- |
500 |
|
- |
| Clause - 5.1, Table-3(SILICON) |
- |
500 |
|
- |
| Clause - 5.1, Table-3(MANGANESE) |
- |
500 |
|
- |
|
31 Dec, 2026 |
- - |
| 462 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
- |
105000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 13.1(Marking (Rating Plates)) |
- |
0 |
|
- |
| 13.2(Terminal Marking Plate) |
- |
0 |
|
- |
| 13.3(Marking ) |
- |
0 |
|
- |
| 13.4(Marking) |
- |
0 |
|
- |
| 13.4.1(Marking) |
- |
0 |
|
- |
| 14.1(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
| 14.2(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
| 14.3(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
| 14.4(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
| 15.1.1(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
| 15.1.2(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
| 15.1.3(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
| 15.1.4(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
| 15.1.5(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
| 21.2 a)(Measurement of winding resistance ) |
- |
1000 |
|
- |
| 21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
2000 |
|
- |
| 21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
8000 |
|
- |
| 21.2 d)(Measurement of no-load loss and current) |
- |
6000 |
|
- |
| 21.2 e)(Measurement of insulation resistance) |
- |
1500 |
|
- |
| 21.2 f)(Induced over-voltage withstand test) |
- |
3999.98 |
|
- |
| 21.2 g)( Separate-source voltage withstand test) |
- |
2500 |
|
- |
| 21.3(a )(Lightning impulse test) |
- |
65000 |
|
- |
| 21.3(b)(Temperature-rise test) |
- |
40000 |
|
- |
| 21.4 a)( Determination of sound levels) |
- |
7000 |
|
- |
| 21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
20000 |
|
- |
| 21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
5000 |
|
- |
| 21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
20000 |
|
- |
| 21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
5000 |
|
- |
| 21.5.2.3( Oil leakage test (routine test)) |
- |
7000 |
|
- |
| 21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
20000 |
|
- |
| 21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
5000 |
|
- |
| 21.5.3.3(Oil leakage test (routine test)) |
- |
7000 |
|
- |
| 21.4 c(No load current at 112.5 percent voltage.) |
- |
2000 |
|
- |
| 21.4 d(Paint adhesion tests) |
- |
5000 |
|
- |
| 21.4 e(BDV and moisture content of oil in the transformer) |
- |
10000 |
|
- |
| 6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
20000 |
|
- |
| 11(Minimum clearance in Air) |
- |
0 |
|
- |
| 16(Conservator for Non-sealed type Transformers) |
- |
0 |
|
- |
| 20(Fittings) |
- |
0 |
|
- |
| 6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
4000 |
|
- |
| 7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
4000 |
|
- |
| 8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
4000 |
|
- |
| 6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
4000 |
|
- |
| 7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
4000 |
|
- |
| 8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
4000 |
|
- |
| 21.5.1.3(Oil leakage test upto 200 KVA) |
- |
7000 |
|
- |
| 9.1 f)(Mineral oil) |
- |
10000 |
|
- |
| 15.2(Pressure and Vacuum Requirements) |
- |
20000 |
|
- |
| 6.1(Rating) |
- |
0 |
|
- |
| 6.2(Rated frequency) |
- |
0 |
|
- |
| 6.3(Nominal system voltage) |
- |
0 |
|
- |
| 6.4(Basic Insulation level ) |
- |
0 |
|
- |
| 6.5(No-Load Voltage Ratios) |
- |
1000 |
|
- |
| 6.6(Winding connections and phase displacement) |
- |
1000 |
|
- |
| 6.7(Tapping Range and Tapping Method) |
- |
0 |
|
- |
| 6.9(Permissible Flux Density and Over Fluxing ) |
- |
20000 |
|
- |
| 7(Technical Parameters of three phase distribution trasnformers
higher than 200kva) |
- |
0 |
|
- |
| 8(Technical Parameters of single phase distribution transformers
UP to and including 25 KVA ) |
- |
0 |
|
- |
| 10(Terminal arrangment ) |
- |
0 |
|
- |
| 18(Efficiency and regulation) |
- |
0 |
|
- |
| 12(Connectors ) |
- |
0 |
|
- |
| 21.5.3.3(Oil leakage test) |
- |
7000 |
|
- |
| 9.1a)(CRGO Electrical Steel) |
- |
0 |
|
- |
| 9.1 b)(Amorphous core material) |
- |
0 |
|
- |
| 9.1 c)(Copper/Aluminium conductor) |
- |
0 |
|
- |
| 9.1 d)(Kraft paper) |
- |
0 |
|
- |
| 9.1 e)(Press Board) |
- |
0 |
|
- |
| 15.5(Total Dry Film Paint Thickness) |
- |
0 |
|
- |
| 10(Terminal Arrangement) |
- |
0 |
|
- |
| 15.4(Gasket) |
- |
0 |
|
- |
| 19(Tolerances) |
- |
0 |
|
- |
| 4(Service Conditions) |
- |
0 |
|
- |
| 5(General ) |
- |
0 |
|
- |
| 9(Standard Materials) |
- |
0 |
|
- |
| 11(Minimum Clearnaces air ) |
- |
0 |
|
- |
| 13(Marking ) |
- |
0 |
|
- |
| 14(Mounting arrangement) |
- |
0 |
|
- |
| 15(Trasnformer Tank ) |
- |
0 |
|
- |
| 16(Conservator for Non-Sealed type Transformers) |
- |
0 |
|
- |
| 18(Efficiency and Regulation) |
- |
0 |
|
- |
| 19(Tolerances) |
- |
0 |
|
- |
| 20(Fittings) |
- |
0 |
|
- |
| 21(General ) |
- |
0 |
|
- |
| 22(Information required with enquiry and order ) |
- |
0 |
|
- |
| 6.8(Losses and impedance values) |
- |
8000 |
|
- |
| 6.1(Limits of Temperature-rise) |
- |
0 |
|
- |
|
28 Nov, 2028 |
- - |
| 463 |
National Test House (NWR) - NTH, Jaipur
| 8122904
| IS 277 (2018) |
Galvanized steel strips and sheets (Plain And Corrugated) - Specification (Seventh Revision) |
- |
4000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 14(Length, Width & Thickness) |
- |
1000 |
|
- |
| 6(Yield Strength-IS:1608(P1)) |
- |
500 |
|
- |
| 6(Elongation-IS:1608(P1)) |
- |
500 |
|
- |
| 6(Tensile Strength-IS:1608(P1)) |
- |
500 |
|
- |
| Cl 10(Galvanising Test) |
- |
2000 |
|
- |
| 5.1(carbon) |
- |
500 |
|
- |
| 5.1(manganese) |
- |
500 |
|
- |
| 5.1(sulphur) |
- |
500 |
|
- |
| 5.1(phosphorus) |
- |
500 |
|
- |
| 5.1(phosphorus) |
- |
500 |
|
- |
| 5.1(Titanium) |
- |
500 |
|
- |
| 7.4(Mass of Coating: Single Spot Test) |
- |
500 |
|
- |
| 7.4(Mass of Coating: Triple Spot Test) |
- |
1000 |
|
- |
| Cl 12(Workmanship) |
- |
500 |
|
- |
| 8.3(Bend test miniral diameter) |
- |
1000 |
|
- |
|
31 Dec, 2026 |
- - |
| 464 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 814 (2004) |
Covered electrodes for manual metal arc welding of carbon and carbon manganese steel - Specification (Sixth Revision) |
- |
32500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 & 8.2(Carbon- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
500 |
|
- |
| 6 & 8.2(Silicon- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
500 |
|
- |
| 6 & 8.2(Manganese- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
500 |
|
- |
| 6 & 8.2(Phosphorous- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
500 |
|
- |
| 6 & 8.2(Sulphur- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
500 |
|
- |
| 6 & 8.2(Vanadium- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
500 |
|
- |
| 6 & 8.2(Nickel- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
500 |
|
- |
| 6 & 8.2(Chromium- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
500 |
|
- |
| 6 & 8.2(Molybdenum- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
500 |
|
- |
| 6 & 8.2(Mn+Ni+Cr+Mo+V - Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
500 |
|
- |
| 7.1.1(Diameter of Core Wire) |
- |
500 |
|
- |
| 7.1.2(Length of Electrodes) |
- |
500 |
|
- |
| 7.2.1(Contact End) |
- |
500 |
|
- |
| 7.2.2(Arc striking End) |
- |
500 |
|
- |
| 7.3(Concentricity of Flux covering with core wire) |
- |
1500 |
|
- |
| 7.4(Defects of Core wire and Coverings) |
- |
500 |
|
- |
| 9.1.2 Table 6 (Ultimate Tensile Strength-Annex F) |
- |
1000 |
|
- |
| 9.1.2 Table 6 ( Yield Stress -Annex F) |
- |
1000 |
|
- |
| 9.1.2 Table 6 (Percentage Elongation on Gauge Length-Annex F) |
- |
1000 |
|
- |
| 9.1.3 Table 6 ( Impact Strength-Annex F) |
- |
4000 |
|
- |
| 9.2(Butt Weld Bend Test-IS 1599) |
- |
8000 |
|
- |
| 9.3(Running PerformanceTest-Annex H) |
- |
2000 |
|
- |
| 9.4(Increased Metal Recovery Test-IS 13043) |
- |
3000 |
|
- |
| 9.5(Diffusible Hydrogen Evaluation Test-IS 11802) |
- |
5000 |
|
- |
| 9.6(Radiographic Test- IS 1182) |
- |
1000 |
|
- |
|
14 Jun, 2027 |
- - |
| 465 |
National Test House (NWR) - NTH, Jaipur
| 8122904
| IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
XLPE insulated, PVC sheathed, armoured cable |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 15.1 a) i)(Annealing Test ( For copper wire ) ) |
- |
1000 |
|
-- |
| 15.1 a) iv)(Resistance test - Main conductor) |
- |
1500 |
|
- |
| 15.1 a) iv)(Resistance test - Neutral conductor) |
- |
500 |
|
- |
| 9.2(Thickness of Insulation - Average) |
- |
500 |
|
- |
| 9.3(Thickness of Insulation - Minimum) |
- |
500 |
|
- |
| 14.3(Thickness of outer sheath - AVERAGE) |
- |
500 |
|
- |
| 14.3(Thickness of outer sheath - minimum) |
- |
500 |
|
- |
| 15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
1000 |
|
- |
| 15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
500 |
|
- |
| 15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
500 |
|
- |
| 15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
500 |
|
- |
| 15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
1000 |
|
- |
| 15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
500 |
|
- |
| 15.1 d) iv) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
500 |
|
- |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
250 |
|
- |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
250 |
|
- |
| 15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
1000 |
|
- |
| 15.1 e) v) (Sheath : Hot deformation) |
- |
500 |
|
- |
| 15.1 e) vi) (Sheath : Heat shock test) |
- |
500 |
|
- |
| 15.1 e) vii) (Sheath : Thermalstability) |
- |
1000 |
|
- |
| 15.1 f)(INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
2000 |
|
- |
| 16.2(HIGH VOLTAGE TEST ) |
- |
2000 |
|
- |
| 16.3(FLAMMABILITY TEST : Unaffected length ) |
- |
500 |
|
- |
| 16.3(FLAMMABILITY TEST : Period of Burning ) |
- |
500 |
|
- |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
1000 |
|
- |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
1000 |
|
- |
| 13.1.2(Armouring: Coverage ) |
- |
500 |
|
- |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
500 |
|
- |
| 15.1 a) ii)(Tensile test (for aluminium) - Before stranding ) |
- |
500 |
|
- |
| 15.1 a) ii)(Tensile test (for aluminium) - After stranding ) |
- |
500 |
|
- |
| 16.13(Test for Halogen Acid Gas Evolution) |
- |
2000 |
|
- |
| 16.14(Temperature Index) |
- |
2000 |
|
- |
| 16.9(Oxygen Index Test) |
- |
2000 |
|
- |
| 15.1 d) v) (Insulation: Waterabsorption(gravimetric)) |
- |
2000 |
|
- |
|
31 Dec, 2026 |
- - |
| 466 |
National Test House (NWR) - NTH, Jaipur
| 8122904
| IS 14255 (1995) |
Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification |
up to and including 1100 volts |
24000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.1 c) iii)(Hot set test: Permanent elongation (set) after cooling - IS 10810: Part 30) |
- |
500 |
|
- |
| 10.1 a) iii)(Resistance test - IS10810: Part 5) |
- |
2000 |
|
- |
| 10.1 c) ii)(Ageing in air oven : Elongation variation- IS 10810: Part 11) |
- |
2000 |
|
- |
| 10.1 c) i)(Physical tests for XLPE Insulation:
elongation at break - IS 10810: part 7) |
- |
500 |
|
- |
| 10.1 g)(High voltage test - IS10810:Part 45) |
- |
2000 |
|
- |
| 10.1 c) iii)(Hot set test: Elongation under load - IS 10810: Part 30) |
- |
500 |
|
- |
| 10.1 f)(Insulation resistance (Volume resistivity) test a) volume resistivity at 27°C - IS 10810: Part 43) |
- |
1000 |
|
- |
| 10.1 b) iii)(Test on messenger conductor: Resistance test - IS 10810: Part 5) |
- |
1000 |
|
- |
| 10.1 c) iv)(Shrinkage test : Shrinkage - 10810:Part 12) |
- |
500 |
|
- |
| 10.1 c) i)(Physical tests for XLPE Insulation:
Tensile strength - IS 10810: Part 7) |
- |
500 |
|
- |
| 7.2( Thickness of insulation) |
- |
500 |
|
- |
| 10.1 c) v)(Water ahsorption (Gravimetric) - IS 10810: Part 33 ) |
- |
1000 |
|
- |
| 10.1 a) ii)(Wrapping test - 10810: Part 3) |
- |
500 |
|
- |
| 10.1 b) i)(Test on messenger conductor: Breaking load - IS 10810: Part 2) |
- |
1000 |
|
- |
| 10.1 b) ii)(Test on messenger conductor: Elongation test - Cl 11.3) |
- |
1000 |
|
- |
| 10.1 a) i)(Tests on phase/street light conductor: tensile test - Test method IS10810:Part 2) |
- |
1000 |
|
- |
| 10.1 d) i)(Physical test for PE insulation:
Tensile strength - IS 10810: Part 7 ) |
- |
500 |
|
- |
| 10.1 d) i)(Physical test for PE insulation: elongation at break - IS 10810: Part 7) |
- |
500 |
|
- |
| 10.1 d) ii)(Melt flow index- IS 10810: Part 23) |
- |
2000 |
|
- |
| 10.1 d) iii)(Carbon Black Content) |
- |
1000 |
|
- |
| 10.1 d) iv)(Vicat softening point -IS 10810: Part 22) |
- |
1000 |
|
- |
| 10.1 d) v)(Environmental stress cracking -IS 10810:Part29) |
- |
1000 |
|
- |
| 4.1(Phase/Street Lighting conductor) |
- |
0 |
|
- |
| 4.2(Messenger (Neutral Conductor or Otherwise)) |
- |
0 |
|
- |
| 5.1(Insulation) |
- |
0 |
|
- |
| 6.1(Flexibility class) |
- |
0 |
|
- |
| 6.2(Compactness) |
- |
0 |
|
- |
| 6.3(Protective barrier) |
- |
0 |
|
- |
| 6.4(size of street lighting conductor) |
- |
0 |
|
- |
| 6.5(Size of messenger conductor ) |
- |
0 |
|
- |
| 6.6(Joints in messenger conductor ) |
- |
0 |
|
- |
| 7.1(Insulation) |
- |
0 |
|
- |
| 7.3(Tolerance on thickness of insulation ) |
- |
0 |
|
- |
| 7.4(Aplication of the insulation ) |
- |
0 |
|
- |
| 7.5(Colour of the insulation ) |
- |
0 |
|
- |
| 8.1(Core identification) |
- |
0 |
|
- |
| 8.2(Core identification) |
- |
0 |
|
- |
| 8.3(Identification by other means) |
- |
0 |
|
- |
| 9.1(Assembly (Laying up)) |
- |
0 |
|
- |
| 9.2(Assembly (Laying up)) |
- |
0 |
|
- |
| 9.3(Direction of lay) |
- |
0 |
|
- |
| 10.1 c) ii)(Ageing in air oven : Tensile strength variation - IS 10810:Part 11) |
- |
0 |
|
- |
| 11.4(Bending Test on the Completed Cable ( Optional) ) |
- |
0 |
|
- |
| 11.4(Bending Test on the Completed Cable ( Optional)) |
- |
0 |
|
- |
| 6.2(No of strands) |
- |
0 |
|
- |
| 6.2(Surface) |
- |
0 |
|
- |
| 6.6(Direction of outer layer) |
- |
0 |
|
- |
| 10.1 c) iv)(Shrinkage test : Crack Observed - 10810:Part 12) |
- |
0 |
|
- |
| 10.1 f)(Insulation resistance (Volume resistivity) test b) volume resistivity at 70°C - IS 10810: Part 43) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 467 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 2830 (2012) |
Carbon steel cast billet ingots, billets, blooms and slabs for re-rolling into steel for general structural purposes - Specification (Third Revision) |
- |
10500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Carbon %) |
- |
500 |
|
- |
| 6.1(Manganese %) |
- |
500 |
|
- |
| 6.1(Sulphur %) |
- |
500 |
|
- |
| 6.1(Phosphorus %) |
- |
500 |
|
- |
| 6.1( Copper %) |
- |
500 |
|
- |
| 6.1( Ti) |
- |
500 |
|
- |
| 6.1(V) |
- |
500 |
|
- |
| 6.1(Mo) |
- |
500 |
|
- |
| 6.1(Ni) |
- |
500 |
|
- |
| 6.1(Cr) |
- |
500 |
|
- |
| 10.1 (a)(Macro-examination) |
- |
1000 |
|
- |
| 10.1 (b)(Sulphur print) |
- |
3000 |
|
- |
| Cl. 10.2(Bend) |
- |
500 |
|
- |
| Cl. 10.3(Camber) |
- |
500 |
|
- |
| Cl 11(Length, Width & Thickness) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 468 |
National Test House (NWR) - NTH, Jaipur
| 8122904
| IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
PVC insulated, unsheathed and sheathed cable/cords |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Annealing test (for copper)) |
- |
1000 |
|
- |
| 4.2(Conductor resistance test) |
- |
1500 |
|
- |
| 5.3(Thickness of Insulation) |
- |
500 |
|
- |
| 8.3(Thickness of Sheath) |
- |
500 |
|
- |
| 9(Overall dimensions) |
- |
500 |
|
- |
| Table 1 iii) c) 1)(Tensile strength (Without ageing)) |
- |
1000 |
|
- |
| Table 1 iii) c) 1)(Elongation (Without ageing)) |
- |
1000 |
|
- |
| Table 1 iii) d) 1)(Sheath -Tensile strength (Without ageing)) |
- |
500 |
|
- |
| Table 1 iii) d) 1)(Sheath- Elongation (Without ageing)) |
- |
500 |
|
- |
| Table 1 iii) c) 2)(Loss of mass- Insulation ) |
- |
1000 |
|
- |
| Table 1 iii) d) 2)(Loss of mass- Sheath ) |
- |
500 |
|
- |
| Table 1 iii) c) 4)(Shrinkage-Insulation) |
- |
500 |
|
- |
| Table 1 iii) d) 4)(Shrinkage- Sheath ) |
- |
500 |
|
- |
| Table 1 iii) c) 5)(Heat shock-Insulation ) |
- |
500 |
|
- |
| Table 1 iii) d) 5)(Heat shock-Sheath ) |
- |
500 |
|
- |
| Table 1 iii) c) 6)(Hot deformation - Indentation depth- Insulation) |
- |
500 |
|
- |
| Table 1 iii) d) 6)(Hot deformation -Indentation depth - Sheath ) |
- |
500 |
|
- |
| Table 1 iii) c) 7)(Thermal stability- Insulation ) |
- |
500 |
|
- |
| Table 1 iii) d) 7)(Thermal stability- Sheath ) |
- |
500 |
|
- |
| 10.2(HV (room temperature)) |
- |
1000 |
|
- |
| 10.1(HV (water immersion)) |
- |
3000 |
|
- |
| table 1 e) 3) (Volume Resistivity - Room temp ) |
- |
1000 |
|
- |
| table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
1000 |
|
- |
| 10.4(Flammability test- Unaffected portion) |
- |
300 |
|
- |
| 10.4(Flammability test-Burning after flame removal) |
- |
200 |
|
- |
| Table 1 iii) d) 9)(Cold impact for sheath) |
- |
500 |
|
- |
| Table 1 iii) c) 8)(Cold bend for insulation) |
- |
500 |
|
- |
| Table 1 iii) d) 8)(Cold bend for sheath) |
- |
500 |
|
- |
| 4.1(Tensile test (for Al)-Before Stranding) |
- |
500 |
|
- |
| 4.1(Tensile test (for Al)- After Stranding) |
- |
500 |
|
- |
| 10.5(Oxygen index) |
- |
2000 |
|
- |
| 10.6(Test for Halogen Acid Gas Evolution) |
- |
2000 |
|
- |
| 10.7(Temperature index) |
- |
2000 |
|
- |
|
31 Dec, 2026 |
- - |
| 469 |
National Test House (NWR) - NTH, Jaipur
| 8122904
| IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
Up to & including 1100 V |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 15.1 a) 1)(Tests on conductor : Annealing test ( for copper )) |
- |
1000 |
|
- |
| 15.1 a) 4)(Tests on conductor : Conductor resistance test) |
- |
2000 |
|
- |
| 9.2(INSULATION : Thickness of Insulation) |
- |
500 |
|
- |
| 14.4.1(Thickness of Outer Sheath : Unarmowed Cables) |
- |
500 |
|
- |
| 14.4.2(Thickness of Outer Sheath : Armoured Cables) |
- |
500 |
|
- |
| 15.1 d)1)(Phyaical tests for insulation : Tensile Test) |
- |
1000 |
|
- |
| 15.1 d)1)(Phyaical tests for insulation : Elongation ) |
- |
500 |
|
- |
| 15.1 d)1)(Physical tests for sheath : Tensile stregth ) |
- |
1000 |
|
- |
| 15.1 d)1)(Physical tests for sheath : Elongation ) |
- |
500 |
|
- |
| 15.1 d)3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
500 |
|
- |
| 15.1 d)3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
500 |
|
- |
| 15.1 d)4)(Hot deformation : Insulation ) |
- |
500 |
|
- |
| 15.1 d)4)(Hot deformation : Sheath ) |
- |
500 |
|
- |
| 15.1 d)5)( Loss of mass in air oven- Insulation ) |
- |
1000 |
|
- |
| 15.1 d)5)( Loss of mass in air oven- sheath ) |
- |
500 |
|
- |
| 15.1 d)6)(Heat shock test- sheath ) |
- |
500 |
|
- |
| 15.1 d)7)(Thermal stability- Sheath ) |
- |
500 |
|
- |
| 15.1 d)7)(Thermal stability- insulation ) |
- |
500 |
|
- |
| 15.1.e(Insulation resistance Test- Volume Resistivity At Room temperature) |
- |
1000 |
|
- |
| 15.1.e(Insulation resistance Test- Volume Resistivity At Maximum rated temperature temperature) |
- |
500 |
|
- |
| 15.1 g)(High voltage test at room temperature) |
- |
1000 |
|
- |
| 16.3.1(High Voltage Test ( Water Immersion Test ) : a.c. Test) |
- |
3000 |
|
- |
| 16.4(Flammability Test- Un affected portion) |
- |
300 |
|
- |
| 16.4(Flammability Test- Period of Burning) |
- |
200 |
|
- |
| 15.4 a)(Cold bend test- Sheath ( Optional test)) |
- |
1000 |
|
- |
| 15.4 b)(Cold impact test- Sheath ( Optional test)) |
- |
1000 |
|
- |
| 13.5.1(ARMOURING : Resistance) |
- |
1000 |
|
- |
| 16.5(Oxygen Index Test) |
- |
2000 |
|
- |
| 16.9(Test for Halogen Acid Gas Evolution) |
- |
2000 |
|
- |
| 16.1(Temperature Index) |
- |
2000 |
|
- |
|
31 Dec, 2026 |
- - |
| 470 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 15658 (2021) |
Concrete Paving Blocks - Specification ( First Revision ) |
- |
26000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) b)(Average Flexural strength ) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) a)(Indivdual Flexural strength (i)) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) ii)(Wet Abrasion resistance (Average of three test specimens)) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) i)( Indivdual Wet Abrasion Resistance ) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) ii)(Dry Abrasion resistance (Average of three test specimens)) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) i)( Indivdual Dry Abrasion Resistance ) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) b)(Compressive strength (Average of eight test specimens)) |
- |
2000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) a)(Indivdual Compressive strength (i)) |
- |
2000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) b)(Water absorption (Average of three test specimens)) |
- |
500 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) a)( Indivdual Water absorption) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (ix)(Deviation from squareness) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Indivdual Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Indivdual Plan Area (Asp)) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Plan Area (Asp)) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Indivdual Thickness of wearing Layer) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Thickness of wearing Layer) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Indivdual Arris/chamfer, Depth) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Depth) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Indivdual Arris/chamfer, Width) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Width) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iv)
(Indivdual Aspect Ratio, L/Th) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iv)
(Aspect Ratio, L/Th) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iii)
(Indivdual Thickness, Th) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iii)
(Thickness, Th) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (ii)
(Indivdual Length, L) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (ii)
(Length, L) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (i)
(Indivdual Width, W) |
- |
500 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) b)(Average Tensile splitting strength ) |
- |
2000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) a)(Indivdual Tensile splitting strength (i)) |
- |
2000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Cumulative Weight losses of specimen after 10, 25 & 50 cycles) |
- |
10000 |
|
- |
|
14 Jun, 2027 |
- - |
| 471 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 1285 (2023) |
WROUGHT ALUMINIUM AND ALUMINIUM ALLOYS EXTRUDED ROUND TUBE AND HOLLOW SECTIONS FOR GENERAL ENGINEERINGPURPOSES SPECIFICATION |
All Grade |
10500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1("The extruded round tube and hollow sections
shall be sound and visually free from harmful
defects. ") |
- |
1000 |
|
- |
| 8("Dimensions and tolerances of the material shall be as laid down in the Indian Standards indicated
below:
a) Extruded round tube IS 2673; and
b) Extruded hollow sections IS 6477.") |
- |
1000 |
|
- |
| 10(Tensile test) |
- |
3000 |
|
- |
| Cl.9.1(Aluminium- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Copper- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Magnesium- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Silicon- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Iron- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Manganese- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Zinc- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Titanium and/ or other grain refining elements- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Chromium- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Remarks (Ti+V) - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Remarks (Cr+Mn) - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Remarks (Total Impurities)- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| 6.2(Slight discoloration due to heat treatment, minor polishing marks and spiral marks due to roll straightening shall not be a cause for rejection.) |
- |
0 |
|
- |
| 9(" Extruded round tubes and hollow sections shall be made from alloys specified in IS 733.
9.2 The chemical analysis of the material shall be carried out either in accordance with the methods specified in IS 504 (Part 1 to 12) and IS 504 (Part 13 to 16) or by any other established instrumental/chemical method. In case of any dispute the method specified in relevant parts of IS 504 shall be used as referee method. However, when the method is not given in IS 504, the referee method shall be as agreed to between the purchaser
and the manufacturer. ") |
- |
0 |
|
- |
|
14 Jun, 2027 |
- - |
| 472 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 1566 (1982) |
Specification for hard - Drawn steel wire fabric for concrete reinforcement (Second Revision) |
All Grade as per Specification |
9000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(DIMENSIONS) |
- |
1000 |
|
- |
| 7(SIZES OF SHEETS ‘OR ROLLS) |
- |
1000 |
|
- |
| 8(MASS) |
- |
1000 |
|
- |
| 11.2(Tensile Test) |
- |
3000 |
|
- |
| 11.3(Reverse Bend Test) |
- |
2000 |
|
- |
| 4.1(Sulphur-Relevant Parts of IS 228) |
- |
500 |
|
- |
| 4.1(Phosphorous-Relevant Parts of IS 228) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 473 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 1785 : Part 2 (1983) |
Specification for plain hard drawn steel wire for prestressed concrete: Part 2 as - Drawn wire (First Revision) |
- |
7000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5.1(Diameter) |
- |
1000 |
|
- |
| Cl 5.1.2(Weight) |
- |
1500 |
|
- |
| Cl 6.1(Tensile Test On UTM) |
- |
2000 |
|
- |
| Cl 6.2(Tensile Test On UTM) |
- |
1000 |
|
- |
| Cl. 7.5(Ductility/ Reverse Bend Test) |
- |
1000 |
|
- |
| 3.1.1(PHOSPHORUS) |
- |
500 |
|
- |
| 3.1.1(SULPHUR) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 474 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 1786 (2008) |
High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) |
Fe 415 to Fe 700, size 8mm-40mm |
29500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 9.4(Rebend Test) |
- |
1000 |
|
- |
| Cl. 9.3, Table 4(Bend Test ) |
- |
1000 |
|
- |
| Cl. 8.1 Table 3(Tensile Strength (TS)) |
- |
1000 |
|
- |
| Cl. 7.2 Table -2 (Nominal Mass) |
- |
1000 |
|
- |
| Cl. 8.1 Table 3(Yield Stress (YS)) |
- |
1000 |
|
- |
| Cl. 8.1 Table 3(Elongation, percentage) |
- |
1000 |
|
- |
| Clause 8.1(Table 3)(Total Elongation at Maximum Force) |
- |
1000 |
|
- |
| Cl. 4.3(Visual Inspection.) |
- |
1000 |
|
- |
| 4.1(Carbon %) |
- |
1416 |
|
Inclusive of GST@18% |
| 4.1(Sulphur %) |
- |
1416 |
|
Inclusive of GST@18% |
| 4.1(Phosphorus %) |
- |
1416 |
|
Inclusive of GST@18% |
| 4.1(Manganese %) |
- |
1416 |
|
Inclusive of GST@18% |
| 4.1(Silicon %) |
- |
1416 |
|
Inclusive of GST@18% |
| 4.1( Nitrogen%) |
- |
2360 |
|
Inclusive of GST@18% |
| 4.1(CE) |
- |
2360 |
|
Inclusive of GST@18% |
| 5.7(PullOut (Bond Test)) |
- |
15000.00 |
|
Fee is dependent on size and exclusive of GST.
Up to 12mm - Rs 10000.00 +GST
Above 12mm - Rs 15000.00 +GST |
| Cl. 8.1 Table 3(TS/YS ratio) |
- |
1000 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Sulphur & Phosphorous) |
- |
500 |
|
- |
| Cl. 5 (Cl.5 Mean area of ribs/unit length (Ar), ) |
- |
1000 |
|
- |
|
14 Jun, 2027 |
- - |
| 475 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 1835 (1976) |
Specification for round steel wire for ropes (Third Revision) |
- |
13000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 7(Workmanship) |
- |
1000 |
|
- |
| Cl 10(Diameter) |
- |
1000 |
|
- |
| Cl 12.2(UTM) |
- |
3000 |
|
- |
| Cl 12.3(Torsion) |
- |
1000 |
|
- |
| Cl 12.4(Reverse Bend) |
- |
1000 |
|
- |
| Cl 12.5(Wrap) |
- |
1000 |
|
- |
| Cl 12.6(Adhesion ) |
- |
1000 |
|
- |
| Cl. 5.1, T-1(C) |
- |
500 |
|
- |
| Cl. 5.1, T-1 ( Grade 1)(S) |
- |
500 |
|
- |
| Cl. 5.1, T-1 ( Grade 1)(P) |
- |
500 |
|
- |
| Cl. 5.1, T-1(Mn) |
- |
500 |
|
- |
| Cl. 5.1, T-1(Si) |
- |
500 |
|
- |
| Cl. 5.1, T-1 ( Grade 5)(Cr) |
- |
500 |
|
- |
| Cl. 5.1, T-1 ( Grade 1)(Ni) |
- |
500 |
|
- |
| Cl. 5.1, T-1 ( Grade 1)(Cu) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 476 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 1875 (1992) |
Carbon steel billets, blooms, slabs and bars for forgings - Specification (Fifth Revision) |
- |
9500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1, 6.2(sulphur) |
- |
500 |
|
- |
| 6.1, 6.2(phosphorus) |
- |
500 |
|
- |
| 6.1, 6.2(carbon) |
- |
500 |
|
- |
| 6.1, 6.2(silicon ) |
- |
500 |
|
- |
| 6.1, 6.2(manganese) |
- |
500 |
|
- |
| Cl 7(Workmanship) |
- |
1000 |
|
- |
| Cl 8(Diameter, Ovality & Weight) |
- |
1000 |
|
- |
| 9.1, table 2(Tensile Strength) |
- |
1000 |
|
- |
| 9.1(Yield Strength-IS:1608(P1)) |
- |
1000 |
|
- |
| 9.1(Elongation on SoA 5.65mm GL) |
- |
1000 |
|
- |
| 9.2(Hardness-HB IS:1500 (P1)) |
- |
2000 |
|
- |
| 12.2(Bend Test) |
- |
600 |
|
- |
| 12.3(grain size) |
- |
600 |
|
- |
| 12.4(Macrostructure) |
- |
600 |
|
- |
| 7(Freedom from defects) |
- |
600 |
|
- |
| 6.1, 6.2(molybdenum) |
- |
600 |
|
- |
| 6.1, 6.2(cromium) |
- |
600 |
|
- |
| 6.1, 6.2(nickel) |
- |
600 |
|
- |
| 6.1, 6.2(tin) |
- |
600 |
|
- |
| 6.1, 6.2(boron) |
- |
600 |
|
- |
| 6.1, 6.2(vanadium) |
- |
600 |
|
- |
| 6.1, 6.2(copper) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 477 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 2062 (2011) |
Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) |
E 250 TO E 650 (Grade - A, B, C, BR & B0 ) |
11000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 10.3 (Cl. 10.3 (Tensile Strength)) |
- |
2000 |
|
- |
| Clause 11.3(Bend Test) |
- |
1000 |
|
- |
| Clause 12(Impact Test) |
- |
4000 |
|
- |
| Clause 15, Table 4(Dimension) |
- |
1000 |
|
- |
| Cl 18(Weight) |
- |
1000 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Carbon Equivalent- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Nickel- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Chromium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Molybdenum- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Vanadium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 10.3 (Cl. 10.3 (Yield Stress)) |
- |
1000 |
|
- |
| Cl. 10.3 (Cl. 10.3 (Elongation %)) |
- |
1000 |
|
- |
|
14 Jun, 2027 |
- - |
| 478 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 2721 (2003) |
Galvanized steel chain link fence fabric - Specification (Second Revision) |
- |
13000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6.1, 6.2, Table 1(Nominal Dia of Mesh wire) |
- |
1000 |
|
- |
| Cl.6.1, 6.2, Table 1(Mesh Size) |
- |
1000 |
|
- |
| Cl.6.3, Table 1(Width of the fabric) |
- |
1000 |
|
- |
| Cl.6.3, Table 1(Length of the fabric) |
- |
1000 |
|
- |
| Cl.9.1.1(Tensile test of mesh and line wires- IS 1608) |
- |
2000 |
|
- |
| Cl.9.1.2(Wrapping test of mesh and line wires-IS 1755) |
- |
1000 |
|
- |
| Cl.9.1.3(Twist test of mesh and line wires-IS 1717) |
- |
1000 |
|
- |
| Cl.9.1.4(Bend test of mesh and line wires- IS 1608) |
- |
1000 |
|
- |
| Cl.9.2(Line wire (Mass of zinc coating)- IS 6745) |
- |
2000 |
|
- |
| Cl.9.2(Line Wire (Uniformity of Zinc coating)-IS 2633) |
- |
1000 |
|
- |
| Cl.9.2(Mesh wire (Mass of zinc coating)- IS 6745) |
- |
2000 |
|
- |
| Cl.9.2(Mesh Wire (Uniformity of Zinc coating)-IS 2633) |
- |
1000 |
|
- |
| Cl.5(Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.5(Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.5(Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.5(Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 479 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 4923 (2017) |
Hollow steel sections for structural use - Specification (Third Revision) |
- |
8000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Depth)) |
- |
1500 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Weigth)) |
- |
1000 |
|
- |
| Cl. 15.2, Table 3(Tensile Strength- IS 1608) |
- |
2000 |
|
- |
| Cl. 15.2, Table 3(Yield Strength- IS 1608) |
- |
500 |
|
- |
| Cl. 15.2, Table 3(Elongation- IS 1608) |
- |
500 |
|
- |
| Cl.7.1(Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.7.1(Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.7.1(Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.7.1(Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.7.1(Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.7.1(Carbon Equivalent-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1500 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Width)) |
- |
500 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections(Thickness)) |
- |
500 |
|
- |
| Cl. 10.1, 14.1, 18.1(Straightness) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 480 |
National Test House (WR) - NTH, Mumbai
| 7107604
| IS 14772 (2020) |
Boxes and Enclosures for Electrical Accessories for Household and Similar Fixed Electrical Installations — General Requirements ( First Revision ) |
- |
14000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Nature of material) |
- |
2000 |
|
- |
| 7.2(Type of installation) |
- |
500 |
|
- |
| 7.3(Types of inlets) |
- |
500 |
|
- |
| 7.4(Clamping means) |
- |
500 |
|
- |
| 7.5(Minimum temperature during installation) |
- |
500 |
|
- |
| 7.9(The provision for fixing accessories to the boxes ) |
- |
500 |
|
- |
| 7.1(The method of fixing the terminals) |
- |
500 |
|
- |
| 8.1(marking) |
- |
500 |
|
- |
| 8.2(By Inspection and The marking is rubbed by hand 15s width a piece of
cloth soaked with water and again for 15s with a piece of cloth soaked with petroleum spirit.) |
- |
500 |
|
- |
| 8.3(BIS Certification Marking) |
- |
500 |
|
- |
| 9.0(Dimensions) |
- |
500 |
|
- |
| 10.0(Protection against electric shock) |
- |
500 |
|
- |
| 11.0(PROVISION FOR EARTHING) |
- |
500 |
|
- |
| 12.0(Constructions) |
- |
500 |
|
- |
| 13.0(Resistance to ingress of solid objects) |
- |
500 |
|
- |
| 13.0(Resistance to ageing) |
- |
1000 |
|
- |
| 14.0(insultation resistance) |
- |
500 |
|
- |
| 14.0(electric strength) |
- |
500 |
|
- |
| 15.0(Mechanical strength) |
- |
500 |
|
- |
| 16.0(resistance to heat) |
- |
1000 |
|
- |
| 17.0(creepage distance) |
- |
500 |
|
- |
| 17.0(clearances) |
- |
500 |
|
- |
| 17.0(distance through seating compund) |
- |
500 |
|
- |
| 18.0(Resistance to insulating material to abnormal heat and fire) |
- |
1000 |
|
- |
| 19.0(Resistance to tracking) |
- |
1000 |
|
- |
| 20.0(Resistance to corrosion) |
- |
500 |
|
- |
| 13.0(Resistance toharmful ingress of water) |
- |
1500 |
|
- |
| 7.6, 7.7, 7.8(The degree of ingress protection) |
- |
2000 |
|
- |
|
- |
- - |