| 481 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 5522 (2014) |
Stainless steel sheets and strips for utensils - Specification (Third Revision) |
- |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl . 6 .0(Freedom from defect) |
- |
1000 |
|
- |
| 8.2, Table 3(Tensile Test-1608:Part 1) |
- |
2000 |
|
- |
| 8.2, Table 3(Proof Stress, N/mm2) |
- |
500 |
|
- |
| 8.2, Table 3(Elongation, %) |
- |
500 |
|
- |
| 8.3(Hardness , max-IS 1500 or IS 1501 (Part 1) or IS 1586) |
- |
2000 |
|
- |
| 8.4(Bend Test) |
- |
1000 |
|
- |
| 8.5(Erichsen Cupping Test) |
- |
2000 |
|
- |
| 10.5(Camber, mm) |
- |
1000 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 482 |
National Test House (WR) - NTH, Mumbai
| 7107604
| IS 302 : Part 2 : Sec 13 (2024) |
Household and Similar Electrical Appliances âSafety Part 2 Particular Requirements Section 13 Deep Fat Fryers, Frying Pans and Similar Appliances (First Revision) |
- |
13000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
500 |
|
- |
| 8(Protection against access to live parts) |
- |
500 |
|
- |
| 10(Power input and current) |
- |
1000 |
|
- |
| 11(Heating) |
- |
1500 |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
500 |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
500 |
|
- |
| 14(Transient overvoltages) |
- |
500 |
|
- |
| 15(Moisture resistance) |
- |
1000 |
|
- |
| 15.3(Moisture resistance) |
- |
500 |
|
- |
| 15.101(Moisture resistance) |
- |
500 |
|
- |
| 16.1 &16.2(Leakage current test) |
- |
500 |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
500 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
500 |
|
- |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
1500 |
|
- |
| 19.101 to to 19.102(Abnormal operation) |
- |
1000 |
|
- |
| 20(Stability and mechanical hazards) |
- |
500 |
|
- |
| 21(Mechanical strength) |
- |
500 |
|
- |
| 22(Construction) |
- |
500 |
|
- |
| 22.101(Construction) |
- |
500 |
|
- |
| 23(Internal wiring) |
- |
500 |
|
- |
| 24(Components) |
- |
500 |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
500 |
|
- |
| 26("Terminals for external
conductors") |
- |
500 |
|
- |
| 27(Provision for earthing) |
- |
500 |
|
- |
| 28(Screws and connections) |
- |
500 |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
500 |
|
- |
| 30(Resistance to heat and fire) |
- |
500 |
|
- |
| 31(Resistance to rusting) |
- |
500 |
|
- |
|
- |
- - |
| 483 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 6527 (1995) |
Stainless steel wire rods - Specification (First Revision) |
- |
11000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(The wire rods shall be smooth on surface and free from harmful surface defects) |
- |
1000 |
|
- |
| 9,
Table 3 & 4 of IS:6527 (Designation X02Cr17Ni12Mo2)(Ultimate Tensile Strength) |
- |
2000 |
|
- |
| 9,
Table 3 & 4 of IS:6527 (Designation X02Cr17Ni12Mo2)(0.2% Proof Stress) |
- |
500 |
|
- |
| 9,
Table 3 & 4 of IS:6527 (Designation X02Cr17Ni12Mo2)(%Elongation) |
- |
500 |
|
- |
| 9,
Table 3 & 4 of IS:6527 (Designation X02Cr17Ni12Mo2)(Hardness) |
- |
2000 |
|
- |
| Cl 10(Diameter & Out Of Round) |
- |
1000 |
|
- |
| 7,
Table 1of IS:6527 (Designation X10Cr17Mn6Ni4)(Carbon) |
- |
500 |
|
- |
| 7,
Table 1of IS:6527 (Designation X10Cr17Mn6Ni4)(Sulphur) |
- |
500 |
|
- |
| 7,
Table 1of IS:6527 (Designation X10Cr17Mn6Ni4)(Phosphorous) |
- |
500 |
|
- |
| 7,
Table 1of IS:6527 (Designation X10Cr17Mn6Ni4)(Manganese) |
- |
500 |
|
- |
| 7,
Table 1of IS:6527 (Designation X10Cr17Mn6Ni4)(Silicon) |
- |
500 |
|
- |
| 7,
Table 1of IS:6527 (Designation X10Cr17Mn6Ni4)(Chromium) |
- |
500 |
|
- |
| 7,
Table 1of IS:6527 (Designation X10Cr17Mn6Ni4)(Nickel) |
- |
500 |
|
- |
| 7,
Table 1of IS:6527 (Designation X10Cr17Mn6Ni4)(Molybdenum) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 484 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 277 (2018) |
Galvanized steel strips and sheets (Plain And Corrugated) - Specification (Seventh Revision) |
GP TO GP 550 |
8000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8.1(UTM) |
- |
4000 |
|
- |
| Cl 8.2(Press) |
- |
1000 |
|
- |
| Cl 12(Workmanship) |
- |
1000 |
|
- |
| Cl 13(Weight) |
- |
1000 |
|
- |
| Cl 14(Length, Width & Thickness) |
- |
1000 |
|
- |
| Cl 10(Galvanising Test) |
- |
2000 |
|
- |
| Cl. 5.1(Carbon) |
- |
500 |
|
- |
| Cl. 5.1(Sulphur) |
- |
500 |
|
- |
| Cl. 5.1(Phosphorous) |
- |
500 |
|
- |
| Cl. 5.1(Manganese) |
- |
500 |
|
- |
| Cl. 5.1(Silicon) |
- |
500 |
|
- |
| Cl. 5.1(Titanium) |
- |
500 |
|
- |
| Cl-5.1(Aluminium) |
- |
500 |
|
- |
| Cl. 5.1(Copper) |
- |
500 |
|
- |
| Cl. 5.1(Vanadium) |
- |
500 |
|
- |
| Cl. 14 & Cl. 15(Depth of corrugation (average of 4)) |
- |
250 |
|
- |
| Cl. 14 & Cl. 15(Pitch of corrugation (average of 4)) |
- |
250 |
|
- |
| Cl. 14 & Cl. 15 (Cl. 14 & Cl 15 (Number of Corrugation)) |
- |
0 |
|
- |
|
14 Jun, 2027 |
- - |
| 485 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 280 (2006) |
Mild steel wire for general engineering purposes (Fourth Revision) |
All Grade as per Specification |
8000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 7 & Table 1(Diameter & Difference Between Two Reading On Any Two Diameters) |
- |
1000 |
|
- |
| Cl 9(Tensile Test On UTM) |
- |
3000 |
|
- |
| 9.2(Wrapping Test) |
- |
2000 |
|
- |
| 9.3(Bend test) |
- |
1000 |
|
- |
| Cl 13(Workmanship) |
- |
1000 |
|
- |
| 11(Coating test) |
- |
2000 |
|
- |
| 13(Freedom from defects) |
- |
1000 |
|
- |
| 6 AND AS PER IS 7887(CARBON) |
- |
500 |
|
- |
| 6 AND AS PER IS 7887(SULPHUR) |
- |
500 |
|
- |
| 6 AND AS PER IS 7887(PHOSPHORUS) |
- |
500 |
|
- |
| 6 AND AS PER IS 7887(MANGANESE) |
- |
500 |
|
- |
| 6 AND AS PER IS 7887(SILICON) |
- |
500 |
|
- |
| 6 AND AS PER IS 7887(ALUMINIUM) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 486 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 432 : Part 1 (1982) |
Mild Steel and Medium Tensile Steel Bars and Hard-Drawn Steel Wire for Concrete Reinforcement: Part 1 Mild Steel and Medium Tensile Steel Bars |
All Grade as per Specification |
9500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 6.1(Diameter) |
- |
1000 |
|
- |
| Cl 6.2(Weight) |
- |
1000 |
|
- |
| Clause 8.1(Ultimate Tensile Stress) |
- |
1000 |
|
- |
| 8.1 & 9.2(Yield Strength - IS: 1608 (P1)) |
- |
1000 |
|
- |
| 8.1 & 9.2(Elongation on SoA 5.65mm GL - IS: 1608 (P1)) |
- |
1000 |
|
- |
| Cl 8.2(Bend test) |
- |
1000 |
|
- |
| Cl 5.1(Workmanship) |
- |
1000 |
|
- |
| Clause -4, 4.1( CARBON) |
- |
500 |
|
- |
| Clause -4, 4.1(SULPHUR) |
- |
500 |
|
- |
| Clause -4, 4.1(PHOSPHURS) |
- |
500 |
|
- |
| Clause -4, 4.1(MANGANESE) |
- |
500 |
|
- |
| Clause -4, 4.1(SILICON) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 487 |
National Test House (WR) - NTH, Mumbai
| 7107604
| IS 12701 (1996) |
Rotational moulded polyethylene water storage tanks - specification (First Revision) |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
6000 |
|
NA |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
6000 |
|
NA |
| 6.1(Finish) |
- |
1000 |
|
NA |
| 7.1.1(Resistance to Deformation) |
- |
2000 |
|
NA |
| 7.2(Resistance to Impact) |
- |
2000 |
|
NA |
| 7.3(Test for Top Load Resistance) |
- |
2000 |
|
NA |
| 7.4(Tensile Strength) |
- |
2000 |
|
NA |
| 7.5(Flexural Modulus) |
- |
2000 |
|
NA |
| 7.6(overall Migration) |
- |
3000 |
|
NA |
|
- |
- - |
| 488 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 432 : Part 2 (1982) |
Mild Steel and Medium Tensile Steel Bars and Hard-Drawn Steel Wire for Concrete Reinforcement: Part 2 Hard-Drawn Steel Wire |
All Grade as per Specification |
8500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5 & 6(Diameter) |
- |
1000 |
|
- |
| Clause 7.1(Ultimate Tensile Stress) |
- |
1000 |
|
- |
| Clause 7.1(Proof Stress (0.2 percent )) |
- |
1000 |
|
- |
| Cl. 7.1(Elongation) |
- |
1000 |
|
- |
| Cl 8.3(Bending To Both Side At 90°, Then Straight) |
- |
1000 |
|
- |
| Cl 4.1(Workmanship) |
- |
1000 |
|
- |
| Clause 3.1.1(Sulphur) |
- |
1000 |
|
- |
| Clause 3.1.1(Phosphorus) |
- |
1000 |
|
- |
|
14 Jun, 2027 |
- - |
| 489 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 733 (1983) |
Specification for wrought aluminium and aluminium alloy bars, rods and sections (For General Engineering Purposes) (Third Revision) |
All Grade as per Specification |
11500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Dimension - IS 3965) |
- |
1000 |
|
- |
| Cl. 5.1, Table 2(Tensile Strength- IS 1816) |
- |
2000 |
|
- |
| Cl. 5.1, Table 2(0.2 Percent proof stress- IS 1816) |
- |
2000 |
|
- |
| Cl. 5.1, Table 2(Elongation on 50 mm or 5.65√So Gauge Length) |
- |
1000 |
|
- |
| Cl. 4(Freedom from Defects) |
- |
1000 |
|
- |
| Cl. 0.4, 5.1, Table 1(Copper- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Magnesium- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Silicon- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Iron- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Cr+ Mn- IS 504 or by any other suitable instrumental method) |
- |
1000 |
|
- |
| Cl. 0.4, 5.1, Table 1(Zinc- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Titanium and / or other grain refining elements - IS 504 or by any other suitable instrumental method) |
- |
1000 |
|
- |
|
14 Jun, 2027 |
- - |
| 490 |
National Test House (WR) - NTH, Mumbai
| 7107604
| IS 14933 (2001) |
High Pressure Fire Fighting Hose -Specification |
Type A |
29000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 3.4(Internal Dia) |
- |
1000 |
|
NA |
| Cl 4(Length) |
- |
1000 |
|
NA |
| Cl 5(Mass) |
- |
1000 |
|
NA |
| Cl 6(Coil Dia) |
- |
1000 |
|
NA |
| Cl 10(Hydaulic Proof Pressure Test) |
- |
5000 |
|
NA |
| Cl 11(Hydraulic Burst Pressure Test) |
- |
5000 |
|
NA |
| Cl 12(Kink test) |
- |
2000 |
|
NA |
| Cl 13 & Annex A(Adhesion Test) |
- |
2000 |
|
NA |
| Cl 14 & Annex B(Abrasion Resistance Test) |
- |
1000 |
|
NA |
| Cl 15(Accelerated Ageing Test) |
- |
8000 |
|
NA |
| Cl 16(Change in Length) |
- |
2000 |
|
NA |
| Cl 17.2(Oil Resistance Test) |
- |
2000 |
|
NA |
| Cl 17.3(Heat Resistance Test) |
- |
2000 |
|
NA |
|
- |
- - |
| 491 |
National Test House (WR) - NTH, Mumbai
| 7107604
| IS 4984 (2016) |
Polyethylene pipes for water supply - Specification (Fifth Revision) |
- |
18000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.10(Slow Crack Growth Rate) |
- |
10000 |
|
i)Size up to 200 mm. Dia.
ii)Acceptance test fee: 18000/-
iii)Type test fee(inclusive of 1000 hrs. test): 27000/-for BIS |
| 8.9 table-6(Elongation at Break) |
- |
1000 |
|
- |
| 8.8(Tensile Strength for Butt-fusion) |
- |
1000 |
|
- |
| 8.7(Density) |
- |
1000 |
|
- |
| 8.5 (Oxidation Induction Time) |
- |
1000 |
|
- |
| 8.4( Melt Flow Rate) |
- |
2000 |
|
- |
| 8.2(Longitudinal Reversion Test) |
- |
1000 |
|
- |
| 8.1.2 table -5(Internal Pressure Creep Rupture Test of Pipe Joints) |
- |
5000 |
|
- |
| 8,/8.1/8.1.1 table-5(PERFORMANCE REQUIREMENTS / Hydraulic Characteristics/ Internal Pressure Creep Rupture Test of Pipe) |
- |
5000 |
|
- |
| 7.4.1.2(Ovality) |
- |
500 |
|
- |
| Cl-7.4(Mean Outside Diameter (For upto 50 mm take 8 reading, above 50mm take 6 reading & average will be reported)) |
- |
1000 |
|
- |
| 7.2(Length) |
- |
500 |
|
- |
| 6.2.1(6.1.1 Identification Stripes) |
- |
500 |
|
- |
| 6.2(Colour) |
- |
500 |
|
- |
| 6.1.4(PIPE DESCRIPTION) |
- |
500 |
|
- |
| 6.1.3 (PIPE DESCRIPTION) |
- |
500 |
|
- |
| 6, 6.1.2(PIPE DESCRIPTION) |
- |
500 |
|
- |
| 6, 6.1.1(PIPE DESCRIPTION) |
- |
500 |
|
- |
| 6, 6.1(PIPE DESCRIPTION) |
- |
500 |
|
- |
| 8.6(Overall migration) |
- |
2000 |
|
- |
| 8.3(Carbon black) |
- |
1500 |
|
- |
| 5.2(Density) |
- |
1000 |
|
- |
| 5.2(MFI @ 1900C/5.0 Kg) |
- |
2000 |
|
- |
| 5.2(Volatile matter Content) |
- |
1000 |
|
- |
| Clause 7.1(Visual Apperance) |
- |
500 |
|
- |
| Clause 8.3(Carbon Black content) |
- |
1500 |
|
- |
| Clause 8.3(Carbon Black Dispersion) |
- |
1000 |
|
- |
| Clause 8.6(Overall migration (stimulate)) |
- |
2000 |
|
- |
| Clause 8.6(Overall migration (surface of material)) |
- |
2000 |
|
- |
| 7.1(Visual Appearance) |
- |
500 |
|
- |
| 7.3(Coiling) |
- |
500 |
|
- |
| Table-2 (iii, iv)(Thermal Stability (Oxidation Induction Time), Volatile Matter) |
- |
1000 |
|
- |
| Cl. 8.3(Carbon Black Content) |
- |
1500 |
|
- |
| Cl. 8.3(Carbon Black Dispersion) |
- |
1000 |
|
- |
| 5.2,T2(Melt Flow rate(Temperature - 190oC,Mass 5kg)-IS 2530-1963) |
- |
2000 |
|
- |
| 8.7(Density-IS 7328:2020) |
- |
1000 |
|
- |
| 8.7(Corrected Density- IS 7328:2020) |
- |
1000 |
|
- |
| 8.9,T6("Tensile - IS 4984-2016
(Annexure-H)") |
- |
1000 |
|
- |
| 8.9,T6("Elongation -IS 4984-2016
(Annexure-H)") |
- |
1000 |
|
- |
| Cl 8.3(Carbon Black Content) |
- |
1500 |
|
- |
| Cl 8.3(Carbon Black Dispersion) |
- |
1000 |
|
- |
| Clause 7.3(Coiling) |
- |
500 |
|
- |
| 7() |
- |
0 |
|
- |
|
- |
- - |
| 492 |
National Test House (WR) - NTH, Mumbai
| 7107604
| IS 4985 (2021) |
UNPLASTICIZED PVC PIPES FOR POTABLE WATER SUPPLIES SPECIFICATION Fourth Revision |
- |
36000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.1(Colour) |
- |
500 |
|
- |
| 10.1(Surface Finish) |
- |
500 |
|
- |
| 7.2.1.1 Table3(Angle of taper (Note-1)) |
- |
500 |
|
- |
| 10.7(Sulphated Ash Content) |
- |
2000 |
|
- |
| 5(CLASSIFICATION OF PIPES) |
- |
500 |
|
- |
| Cl-7.1(Mean out side Diameter (For less than or equal to 40 mm- Average of 8 , For higher diameters up to 110 mm average of 6)) |
- |
200 |
|
- |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Minimum)) |
- |
200 |
|
- |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Mamimum)) |
- |
200 |
|
- |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. Variation) |
- |
200 |
|
- |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Minimum)) |
- |
200 |
|
- |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Maximum)) |
- |
200 |
|
- |
| 7.1.1.2(DIMENSIONS-PIPE-Ovality (Maximum)) |
- |
200 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Minimum)) |
- |
200 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Maximum)) |
- |
200 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Average Thickness) |
- |
200 |
|
- |
| Cl- 7.2(Socket length (Take 4 reading & minimum will be reported)) |
- |
200 |
|
- |
| 7.2.1(DIMENSIONS-Socket) |
- |
200 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Minimum Length) |
- |
200 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Minimum)) |
- |
200 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Maximum)) |
- |
200 |
|
- |
| 7.2.1.2(a)-Table 5(DIMENSIONS-Sockets for elastomeric sealing ring joints-Minimum depth of engagement) |
- |
200 |
|
- |
| 7.2.1.2-Table 4(DIMENSIONS-Sockets for elastomeric sealing ring joints-Socket inner Diameter) |
- |
200 |
|
- |
| 8(SEALING RINGS) |
- |
200 |
|
- |
| 9.1(PIPE ENDS) |
- |
500 |
|
- |
| 10.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
500 |
|
- |
| 10.1.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
500 |
|
- |
| 10.2(PHYSICAL AND CHEMICAL CHARACTERISTICS-Opacity) |
- |
1000 |
|
- |
| 10.4(PHYSICAL AND CHEMICAL CHARACTERISTICS- Reversion Test) |
- |
2000 |
|
- |
| 10.5(PHYSICAL AND CHEMICAL CHARACTERISTICS- Vicat Softening Temperature) |
- |
2000 |
|
- |
| 10.6(PHYSICAL AND CHEMICAL CHARACTERISTICS- Density) |
- |
1000 |
|
- |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)) |
- |
20000 |
|
- |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)) |
- |
5000 |
|
- |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)-for Integral Sealing Ring Sockets) |
- |
20000 |
|
- |
| 11.1.1(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Plumbing pipes) |
- |
5000 |
|
- |
| 11.2(Resistance to External Blows at 0°C) |
- |
2000 |
|
- |
| 10.3(Effect on Water Test) |
- |
5000 |
|
All tests except Dialkyl TinC4 and higher homologues measured as Tin, Other Toxic substances |
| 7.1.3(mean outside diameter, outside diameter at
any point, and wall thickness of plumbing pipes) |
- |
500 |
|
- |
| 7.1.4(Length) |
- |
500 |
|
- |
| 7.2.1.2b(Maximum inner diameter of groove) |
- |
200 |
|
- |
| 13.1(Marking) |
- |
200 |
|
- |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Integral Sealing Ring Sockets) |
- |
5000 |
|
- |
| 6.1.2(PVC Resin) |
- |
0.03 |
|
- |
| 6.1.1(VCM Content) |
- |
0 |
|
- |
|
- |
- - |
| 493 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 733 (2025) |
Wrought Aluminium and Aluminium Alloy Bars, Rods, Sections, Extruded Tube, Hollow Sections and Profiles for General Engineering Purposes ? Specification (Fourth Revision) |
- |
12500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6 Table 1 - Table 8(Zirconium +Titanium) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Fe) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Cu) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Mn) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Mg) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Cr) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Zn) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Ti) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(V) |
- |
500 |
|
- |
| Cl-7.1, 7.2 & 7.3, Table-9(Dimensions) |
- |
1000 |
|
- |
| Cl-7.1, 7.2 & 7.3, Table-9(Rm MPa) |
- |
2000 |
|
- |
| Cl-7.1, 7.2 & 7.3, Table-9(Rp0.2 MPa) |
- |
2000 |
|
- |
| Cl-7.1, 7.2 & 7.3, Table-9(Elongation , Percent) |
- |
1000 |
|
- |
| Cl-9(Dimensions and Tolerances) |
- |
0 |
|
- |
| Cl-12(Packaging and Marking) |
- |
0 |
|
- |
| Cl-7.1(Tensile test) |
- |
0 |
|
- |
| Cl-5(Freedom from Defects) |
- |
1000 |
|
- |
| Cl-6.1, Table-1 to 8(Si) |
- |
500 |
|
- |
| Cl-4(General requirements) |
- |
0 |
|
- |
| Cl-6.1, Table-1 to 8(Aluminium) |
- |
500 |
|
- |
| Cl-6.2(chemical analysis) |
- |
0 |
|
- |
|
14 Jun, 2027 |
- - |
| 494 |
National Test House (WR) - NTH, Mumbai
| 7107604
| IS 636 (2018) |
Non - Percolating flexible fire fighting delivery hose - Specification (Fourth Revision) |
- |
32000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 6.1.1(Inner lining shall be of rubber or rubberized fabric lining which is generally smooth and practically free
from pitting and other imperfections) |
- |
1000 |
|
Type 1: Rs. 25,000/- ,Type 2: Rs. 29000 /- ,Type 3: Rs. 32000/- |
| Cl 6.1.2(Externally applied elastomeric coating or
covering of the reinforcement, if present shall be
generally smooth and practically free from pitting and
other imperfections) |
- |
1000 |
|
- |
| Cl 6.1.3(The jacket shall be practically free from dirt, knots,
lumps, irregularities of the yarn and other visible defects.) |
- |
1000 |
|
- |
| Cl.6.2(The internal diameter of the hose shall be measured by
a suitable conical plug gauge and shall conform to the
specified diameter with a tolerance of plus 2 and minus
0.0 mm.) |
- |
1000 |
|
- |
| Cl.6.3(Unless specified otherwise, the standard length shall
be 30 m. Unless otherwise specified, a tolerance of ± 2
percent shall be permitted on the length prescribed for
the hose by the purchaser but the total of all lengths of
hose supplied shall be not less than the total quantity
specified by the purchaser.) |
- |
1000 |
|
- |
| Cl.6.4(The average mass of hose per meter of 2 m length,
without couplings attached, shall not be more than that
prescribed in Table 1. For the determination of mass,
sample of the hose shall be conditioned at 27 ± 2°C and
65 ± 5 percent relative humidity for a period of at least
48 h and then shall be weighed under the same conditions.) |
- |
1000 |
|
- |
| Cl.6.5(For 30 m length of dry hose without couplings, the coil
diameter shall not exceed 45 cm for Type 1, 50 cm for
Type 2 and 55 cm for Type 3.) |
- |
1000 |
|
- |
| Cl.6.6(Each hose length shall be subjected to an internal hydraulic pressure of 23 kgf/cm² in accordance with 8.1 of IS 443
(Part 3) increasing the pressure at the rate not exceeding
10 kgf/cm² per min and maintaining it for 1 min. Within
this 1 min, the hose shall neither develop any leakage or
sweating, nor shall any thread in the jacket break.) |
- |
5000 |
|
- |
| Cl.6.7(A test length of hose, 1 m clear of fittings when
subjected to an internal hydraulic pressure in
accordance with 8.3 of IS 443 (Part 3) while increasing
the pressure at the rate not exceeding 10 kgf/cm2 per
min shall not burst or show leakage before a pressure
of 38 kgf/cm2 is reached) |
- |
5000 |
|
- |
| Cl.6.8(There shall be no sign of leakage or rupture and no thread in the jacket shall break after retaining the internal hydraulic pressure of 23 kgf/cm2 for 30 seconds.) |
- |
1000 |
|
- |
| Cl.6.9(The increase in length shall not exceed 6 percent at an internal hydraulic pressure of 10 kgf/cm2 for 2 minutes.) |
- |
1000 |
|
- |
| Cl.6.10(The increase in diameter shall not be more than 10% at an internal hydraulic pressure of 10 kgf/cm2 for 2 minutes.) |
- |
1000 |
|
- |
| Cl 6.11 (Adhesion (Cl. 6.11.1))(Rate of separation shall not exceed 25 mm/min 1) Cover) |
- |
1000 |
|
- |
| Cl 6.11 (Adhesion (Cl. 6.11.1))(Rate of separation shall not exceed 25 mm/min 2) Jet) |
- |
1000 |
|
- |
| Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 1)(After ageing, there shall be no tackiness on the surface of lining or the surface of the cover. ) |
- |
1000 |
|
- |
| Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 2)(shall meet the requirements. given in Cl.6.7 (A test length of hose, 1 m clear of fittings when
subjected to an internal hydraulic pressure in
accordance with 8.3 of IS 443 (Part 3) while increasing
the pressure at the rate not exceeding 10 kgf/cm2 per
min shall not burst or show leakage before a pressure
of 38 kgf/cm2 is reached)) |
- |
1000 |
|
- |
| Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 3)(Rate of separation shall not exceed 25 mm/min 1) Cover) |
- |
1000 |
|
- |
| Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 3)(Rate of separation shall not exceed 25 mm/min 2) Jet) |
- |
1000 |
|
- |
| Cl.6.12(When determined by the method described in Annex C,
the average number of cycles completed before bursting
of three test pieces, shall not be less than the value
specified in Table 2.) |
- |
1000 |
|
- |
| Cl.6.13(When tested in accordance with Annex D, the amount
of moisture absorbed shall not exceed 0.20 kg/m2 for
Type 2 hoses and 0.02 kg/m2 for Type 3 hoses.) |
- |
1000 |
|
- |
| Cl.6.14(When tested by the method described in Annex E, none
of the test samples shall burst at less than 8 s of the
application of the hot cube for Type 2 and 20 s for
Type 3 hose.) |
- |
2000 |
|
- |
| Cl.6.15 (1)(The length shall be laid horizontally and
the central fully immersed portion of the hose shall be
visually examined for any swelling of rubber,
weathering and cracking in the rubber lining) |
- |
1000 |
|
- |
| Cl.6.15 (2)(Rate of separation shall not exceed 25 mm/min 1) Cover) |
- |
1000 |
|
- |
| Cl.6.15 (2)(Rate of separation shall not exceed 25 mm/min 2) Jet) |
- |
1000 |
|
- |
| Cl.6.16(When tested by the method prescribed in
IS 443 (Part 1), the lining (for Types 1, 2 and 3) and
cover (for Type 3 only) of the hose shall neither develop
cracking nor crazing when seen under X2
magnification, except at the cut edges of the hose) |
- |
0 |
|
- |
| Cl.6.17(When tested in accordance with Annex F, at a test
temperature of, at a test temperature of 300 ± 10°C for
Types 1 and 2, and 400 ± 10° C for Type 3, in none of
the four tests shall the test piece show signs of leakage
within 120 s from the application of the filament rod or
on removal of this filament rod after the specified period) |
- |
0 |
|
- |
| Cl.6.18(When tested in accordance with Annex H, the pressure
loss per 23 m length shall not exceed the values specified
in Table 3 at the specified flow rate and inlet pressure
(Recommendations for pressure testing of hoses in
service are given at Annex G).) |
- |
0 |
|
- |
|
- |
- - |
| 495 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 738 (1994) |
Wrought aluminium alloys, drawn tube for general engineering purposes - Specification (Third Revision) |
All Grade |
11500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.7, IS 2678(Wall Thickness at any point) |
- |
500 |
|
- |
| Cl.7, IS 2678(Mean Wall Thickness) |
- |
500 |
|
- |
| Cl. 9.1 Table 2(Tensile Strength- IS 2657) |
- |
2000 |
|
- |
| Cl. 9.1 Table 2(0.2 percent proof stress- IS 2657) |
- |
2000 |
|
- |
| Cl. 9.1 Table 2(Elongation on guage length of 50 mm) |
- |
1000 |
|
- |
| Cl. 6(Freedom from Defects- Cl.6) |
- |
1000 |
|
- |
| Cl. 8.1, Table 1(Aluminium- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
500 |
|
- |
| Cl. 8.1, Table 1(Copper- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
500 |
|
- |
| Cl. 8.1, Table 1(Magnesium- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
500 |
|
- |
| Cl. 8.1, Table 1(Silicon- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
500 |
|
- |
| Cl. 8.1, Table 1(Iron- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
500 |
|
- |
| Cl. 8.1, Table 1(Manganese- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
500 |
|
- |
| Cl. 8.1, Table 1(Zinc- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
500 |
|
- |
| Cl. 8.1, Table 1(Titanium- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
500 |
|
- |
| Cl. 8.1, Table 1(Chromium- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 496 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 303 (2024) |
Plywood for General Purposes â Specification (Fourth Revision) |
- |
13000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.2, Table-2(Maximum Number of Categories of Permissible Defects, per m2) |
- |
500 |
|
- |
| Cl-8.1(Dimensions -length) |
- |
1000 |
|
- |
| Cl-8.2(Thickness of the plywood boards) |
- |
500 |
|
- |
| Cl-8.3(Squareness) |
- |
1000 |
|
- |
| Cl-11.3.1, 11.3.1.1(Water Resistance Test) |
- |
2000 |
|
- |
| Cl-11.3.2(Mycological Test) |
- |
1500 |
|
- |
| Cl-11.4(Moisture Content) |
- |
1000 |
|
- |
| Cl-11.5, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
2000 |
|
- |
| Cl-11.5, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
2000 |
|
- |
| Cl-5.1(Classification by appearance) |
- |
500 |
|
- |
| Cl-5.2, Table- 1 (i)(Blister) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (ii)(Checks) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (iii)(Discolouration) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (iv)(Dote) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (v)(Insect hole) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (vi)(Joints) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (vii)(Knots (dead)) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (viii)(Pin knots (dead)) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (ix)(Pin knots (live)) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (x)(Knots (tight)) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (xi)(Patches) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (xii)(Splits) |
- |
250 |
|
- |
| Cl-5.2, Table- 1 (xiii)(Swirl) |
- |
250 |
|
- |
| Cl-7.2.1(Thickness of veneers) |
- |
500 |
|
- |
| Cl-7.2.3(Grain Direction) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 497 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 13801 (2013) |
Chequered Cement Concrete Tiles - |
- |
7000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| (Cl 7, 8 &9)(Length, Breadth, Thickness, Difference in length of side between the longest side and shorterst side in the sample shall not exceed 1 mm, Half tiles, Difference in Thickness between the thickest and thinnest tile in the sample shall not exceed 10 percent of minimum thickness, Depth of chequred groove, Thickness of wearing layer.) |
- |
500 |
|
- |
| Cl 12.1(Concavity & Convexity ) |
- |
500 |
|
- |
| Cl 12.2(Longest gap between the arms of the square and the edge of the title shall not exceed 2 percent of the length.) |
- |
500 |
|
- |
| Cl 12.3(Shall not exceed 1 percent of the length of the edge.) |
- |
500 |
|
- |
| Cl 12.4(Water absorption) |
- |
1000 |
|
- |
| Cl 12.5(Wet transverse strength) |
- |
2000 |
|
- |
| Cl 12.6(Resistance to wear) |
- |
2500 |
|
- |
|
14 Jun, 2027 |
- - |
| 498 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 1079 (2017) |
Hot rolled carbon steel sheet, plate and strip - Specification (Seventh Revision) |
All Grade |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 13(Length, Width & Thickness) |
- |
1000 |
|
- |
| 8, Table 5 & 6(Tensile Strength) |
- |
1000 |
|
- |
| 8, Table 5 & 6(Yield Strength) |
- |
1000 |
|
- |
| 8, Table 5 & 6(Elongation) |
- |
1000 |
|
- |
| 9(Bend test) |
- |
1000 |
|
- |
| Clause 10(Cuppping Test) |
- |
2000 |
|
- |
| Cl 12(Workmanship) |
- |
1000 |
|
- |
| 6.1(Carbon %) |
- |
500 |
|
- |
| 6.1(Sulphur %) |
- |
500 |
|
- |
| 6.1(Phosphorus %) |
- |
500 |
|
- |
| 6.1(Manganese %) |
- |
500 |
|
- |
| 6.1(Silicon %) |
- |
500 |
|
- |
| 6.1(V) |
- |
500 |
|
- |
| 6.1( Ti) |
- |
500 |
|
- |
| 6.1( Nb) |
- |
500 |
|
- |
| 6.1( Nitrogen%) |
- |
500 |
|
- |
| 6.1( Aluminium %) |
- |
500 |
|
- |
| 6.1( Copper %) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 499 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 1856 (2005) |
Steel wire ropes for haulage purposes - Specification (Third Revision) |
All Grade as per Specification |
8500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4- Tables 1 to 4(Diameter) |
- |
1000 |
|
- |
| 5- Tables 1 to 4(Breakiing Force of Rope with Steel Core) |
- |
3000 |
|
- |
| 6.3(Lay) |
- |
1000 |
|
- |
| 6.4- Tables 1 to 4(Mass of Rope with Steel core) |
- |
1500 |
|
- |
| 7(Uniformity of Znic coating - IS 1835 & IS 2366) |
- |
1000 |
|
- |
| 7(Mass of Znic Coating - IS 1835 & IS 6745) |
- |
2000 |
|
- |
| 5- Tables 1 to 4(Breakiing Force of Rope with Fiber Core) |
- |
3000 |
|
- |
| 6.4- Tables 1 to 4(Mass of Rope with Fiber core) |
- |
1500 |
|
- |
|
14 Jun, 2027 |
- - |
| 500 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 10702 (1992) |
Rubber hawal chappal - Specification (Second Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.4(Stud bolt) |
- |
1000 |
|
- |
| 5.4(Stud diameter) |
- |
1000 |
|
- |
| 5.4(Hardness (Shore A)) |
- |
1000 |
|
- |
| 5.4(Hardness (shore A)- after ageing) |
- |
1000 |
|
- |
| 5.4(Tear strength ) |
- |
1000 |
|
- |
| 5.4(Breaking strength ) |
- |
1000 |
|
- |
| 5.4(Elongation at break ) |
- |
1000 |
|
- |
| 5.4(Tensile Strength ) |
- |
1000 |
|
- |
| 5.4(Relative density ) |
- |
1000 |
|
- |
| 5.4(Shrinkage test (at 100 C temp)) |
- |
1000 |
|
- |
| 5.4(Shrinkage test (at room temp)) |
- |
1000 |
|
- |
| 5.4(Split tear strength ) |
- |
1000 |
|
- |
| 5.4(Compression set) |
- |
1000 |
|
- |
| 5.4(Hardness (Shore A)) |
- |
1000 |
|
- |
| 5.4(Relative density) |
- |
1000 |
|
- |
| 5.3(Thickness ) |
- |
1000 |
|
- |
| 5.1(Shape & Design) |
- |
1000 |
|
- |
|
14 Jun, 2027 |
- - |
| 501 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 1029 (1970) |
Specification for hot-rolled steel strip (Baling) (First Revision) |
All Grades |
8000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.2(Width) |
- |
500 |
|
- |
| 8.2(Thickness) |
- |
500 |
|
- |
| 5.2(Tensile Strength, Mpa) |
- |
1000 |
|
- |
| 5.2(Tensile Test-1608:Part 1) |
- |
1000 |
|
Yield Strength / 0.2 % Proof Stress |
| 5.2(Elongation, %) |
- |
1000 |
|
- |
| 5.3(Bend Test-1599) |
- |
1000 |
|
- |
| Cl.4(Sulphur -IS 228 or method specified in relevant ISO standard) |
- |
500 |
|
- |
| Cl.4(Phosphorus -IS 228 or method specified in relevant ISO standard) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 502 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 1489 (Part 1) (2015) |
Portland pozzolana cement - Specification: Part 1 fly Ash Based |
PPC (Fly Ash Based) |
11000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 -Table 2- i(Fineness 4031 Part 2) |
- |
1000 |
|
- |
| 7 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
500 |
|
- |
| 7 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
1000 |
|
- |
| 7 -Table 2- ii- a(Expansion after aeration - 4031 Part 3) |
- |
0 |
|
- |
| 7 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
250 |
|
- |
| 7 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
250 |
|
- |
| 7 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 7 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 7 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 7 -Table 2- vi(Drying Shrinkage- IS 4031 Part 10) |
- |
1000 |
|
- |
| 7 -Table 2- v(Transverse Strength - IS 4031 Part 8 (Optional)) |
- |
2000 |
|
- |
| 6 - Table - 1 vi( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 v(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 iv(Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 ii(Magnesia - Cl 7.2 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 i(Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
1000 |
|
- |
|
14 Jun, 2027 |
- - |
| 503 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 455 (2015) |
Portland slag cement - Specification |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 Table 1 i(Fineness
IS 4031(Part 2)) |
- |
1000 |
|
- |
| Cl. 7 Table-2(Cl. 7 Table-2 ii a (Soundness , Le Chatelier Expansion )) |
- |
500 |
|
- |
| 7 Table 1 ii b(Soundness, Autoclave expansion
IS 4031(Part 3) ) |
- |
1000 |
|
- |
| 7 Table 1 iii a(Setting Time ( by Vicat Apparatus ),Initial
IS 4031(Part 5)) |
- |
250 |
|
- |
| 7 Table 1 iii b(Setting Time ( by Vicat Apparatus ), Final
IS 4031(Part 5)) |
- |
250 |
|
- |
| 7 Table 1 iv a(Compretsive Strenqth .72 ± 1 hr
IS 4031(Part 6)) |
- |
1000 |
|
- |
| 7 Table 1 iv b(Compretsive Strenqth 168 ± 2 hr
IS 4031(Part 6)) |
- |
1000 |
|
- |
| Cl. 7 Table-2(Cl. 7 Table-2 ii b (Expansion after aeration )) |
- |
0 |
|
- |
| 7 Table 1 iv c(Compretsive Strenqth 672 ± 4 hr
IS 4031(Part 6)) |
- |
1000 |
|
- |
| 7 Table 1 v(Transverse strength (optional)
IS 4031(Part 8) ) |
- |
2000 |
|
- |
| 6 - Table - 1 vii( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 vi(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 v(Loss on ignition - Cl 6.2 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 iv(Sulphide sulphur (S) - Cl 6.12 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 6.11 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 ii(Magnesia - Cl 6.8 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 i(Insoluble residue - Cl 6.9 of IS 4032:1985) |
- |
1000 |
|
- |
|
14 Jun, 2027 |
- - |
| 504 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 269 (2015) |
Ordinary portland cement - Specification (Sixth Revision) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 Table-3 i.(Fineness) |
- |
1000 |
|
- |
| 7 Table-3 ii a(Expansion by Le Chatelier) |
- |
500 |
|
- |
| 7 Table-3 ii b(Expansion by Autoclave) |
- |
1000 |
|
- |
| 7 Table-3 ii b(Expansion after aeration) |
- |
0 |
|
- |
| 7 Table-3 iii a(Setting Time Initial) |
- |
250 |
|
- |
| 7 Table-3 iii b(Setting Time Final) |
- |
250 |
|
- |
| 7 Table-3 iv a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 7 Table-3 iv b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 7 Table-3 iv c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 6.1 Table-2 viii(Alkali content) |
- |
500 |
|
- |
| 6.1 Table-2 vii(Chloride content) |
- |
500 |
|
- |
| 6.1 Table-2 vi(Loss on ignition) |
- |
500 |
|
- |
| 6.1 Table-2 v(Total Sulphur Content calculated as Sulphuric Anhydride) |
- |
500 |
|
- |
| 6.1 Table-2 iv(Magnesia) |
- |
500 |
|
- |
| 6.1 Table-2 iii.(Insoluble residue) |
- |
500 |
|
- |
| 6.1 Table-2 ii.(Ratio of percentage of alumina to that of iron oxide) |
- |
500 |
|
- |
| 6.1 Table-2 i.(Ratio of percentage of lime to percentage of silica, alumina and iron oxide) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 505 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 15477 (2019) |
Adhesives for use with ceramic tiles and mosaics |
Type-1, 2, 3, 4, 5 |
23000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Classification) |
- |
1000 |
|
- |
| 5.1(Tensile Adhesion Strength ) |
- |
2500 |
|
Tensile Adhesion Strength- Dry Condition |
| 5.1(Tensile Adhesion Strength) |
- |
2500 |
|
Tensile Adhesion Strength- Wet Condition |
| 5.2(Shear Adhesion Strength ) |
- |
3000 |
|
Shear Adhesion Strength- Dry Condition |
| 5.2(Shear Adhesion Strength) |
- |
3000 |
|
Shear Adhesion Strength- Wet Condition |
| 5.2(Shear Adhesion Strength) |
- |
3000 |
|
Shear Adhesion Strength- Heat Ageing Condition |
| 5.3(OpenTime) |
- |
1000 |
|
Open time |
| 5.4(Adjustment Time) |
- |
1000 |
|
Adjustment Time |
| 5.5(Slip (Required for Vertical Application Only)) |
- |
3000 |
|
Slip |
| 5.6(Deformability (Required for VerticalApplication Only)) |
- |
3000 |
|
Deformability |
|
14 Jun, 2027 |
- - |
| 506 |
National Test House (NWR) - NTH, Jaipur
| 8122904
| IS 398 : Part 4 (1994) |
Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
- |
9000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Freedom from Defects) |
- |
500 |
|
- |
| 7.1 Table-1(Dimensional measurement of wires) |
- |
500 |
|
- |
| 7.2.2 Table-2, Table-4(Calculated resistance of Stranded Conductor) |
- |
500 |
|
- |
| 8.1(Joints in wires-Conductors Containing Seven Wires) |
- |
500 |
|
- |
| 8.2(Joints in wires-Conductors Containing More Than Seven Wires) |
- |
500 |
|
- |
| 9.1(Stranding) |
- |
500 |
|
- |
| 9.2 Table 3(Lay Ratio of stranded conductors) |
- |
500 |
|
- |
| 9.3(Direction of Lay) |
- |
500 |
|
- |
| 9.4(Multiple layers of wires) |
- |
500 |
|
- |
| 11(Packing and Marking) |
- |
100 |
|
- |
| 12.2 Table 1(Breaking Load Test- Before Stranding) |
- |
4000 |
|
- |
| 12.2 Table 1(Breaking Load Test- After Stranding) |
- |
4000 |
|
- |
| 12.3 Table 1(Elongation Test- Before Stranding) |
- |
4000 |
|
- |
| 12.3 Table 1(Elongation Test- After Stranding) |
- |
4000 |
|
- |
| 12.4 Table 1(Resistance of Aluminium wire) |
- |
4000 |
|
- |
| 9.2(Lay Ratio 24 wire layer) |
- |
500 |
|
- |
| 9.2(Lay Ratio 18 wire layer) |
- |
500 |
|
- |
| 9.2(Lay Ratio 12 wire layer) |
- |
500 |
|
- |
| 9.2(Lay Ratio 3/6 wire layer) |
- |
500 |
|
- |
|
31 Dec, 2026 |
- - |
| 507 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 3319 (1995) |
Blades, surgical, detachable (Bard Parker Type) and handles - Specification (Fourth Revision) |
- |
14900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5,5.1 & 5.2; Table 1(Shape and dimensions) |
- |
1000 |
|
- |
| 6,6.1(Workmanship and Finish) |
- |
1000 |
|
- |
| 6,6.2(Workmanship and Finish) |
- |
0 |
|
- |
| 6,6.3(Workmanship and Finish) |
- |
0 |
|
- |
| 6,6.4(Workmanship and Finish) |
- |
0 |
|
- |
| 7.1(Hardness test) |
- |
2000 |
|
- |
| 9.1( Visual Examination) |
- |
1000 |
|
- |
| 9.2( Performance Test) |
- |
2000 |
|
- |
| 10.1.1( Marking on Blade) |
- |
100 |
|
- |
| 10.1.2(Packages of Non-sterile Blades) |
- |
100 |
|
- |
| 10.1.3,10.1.3.1(Packages of sterile Blades,Unit containers for sterile Blades) |
- |
100 |
|
- |
| 10.1.3,10.1.3.2(Packages of sterile Blades , Outer containers for sterile blade) |
- |
0 |
|
- |
| 10.2( Handles) |
- |
0 |
|
- |
| 10.2.2( Packages of Handles) |
- |
100 |
|
- |
| 11,11.1,11.1.1( Packages of Non-sterile Blades ; Unit container) |
- |
0 |
|
- |
| 11,11.1,11.1.2( Packages of Non-sterile Blades ; Outer container) |
- |
0 |
|
- |
| 11.2,11.2.1(Packages of Sterile Blades) |
- |
0 |
|
- |
| 11.2,11.2.2( Packages of Sterile Blades ; Unit container) |
- |
0 |
|
- |
| 11.2,11.2.3( Packages of sterile Blades ; Outer container) |
- |
0 |
|
- |
| 11.4(Packaging of Handles) |
- |
0 |
|
- |
| Clause -4, 4.1(TITANIUM) |
- |
500 |
|
- |
| Clause -4, 4.1(VANADIUM) |
- |
500 |
|
- |
| Clause -4, 4.1(Molybdenum) |
- |
500 |
|
- |
| Clause -4, 4.1(Chromium) |
- |
500 |
|
- |
| Clause -4, 4.1(Nickel) |
- |
500 |
|
- |
| Clause -4, 4.1( ALUMINIUM) |
- |
500 |
|
- |
| Clause -4, 4.1(SILICON) |
- |
500 |
|
- |
| Clause -4, 4.1(MANGANESE) |
- |
500 |
|
- |
| Clause -4, 4.1(PHOSPHURS) |
- |
500 |
|
- |
| Clause -4, 4.1(SULPHUR) |
- |
500 |
|
- |
| Clause -4, 4.1( CARBON) |
- |
500 |
|
- |
|
14 Jun, 2027 |
- - |
| 508 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
1200 |
|
- |
| 6(Interchangeability) |
- |
1200 |
|
- |
| 7(Protection against accidental contact with live parts) |
- |
1200 |
|
- |
| 8(Insulation Resistance and Electric Strength) |
- |
5000 |
|
- |
| 9(MECHANICAL STRENGTH) |
- |
1200 |
|
- |
| 10(cap temperature) |
- |
2000 |
|
- |
| 11(Resistance to Heat) |
- |
2000 |
|
- |
| 12(Resistance to Flame and Ignition) |
- |
5000 |
|
- |
| 13(Fault conditions) |
- |
2000 |
|
- |
| 14(Creepage distance and clearances) |
- |
1200 |
|
- |
| 4(General requirement and General test requirements) |
- |
0 |
|
- |
| 8(Strength after humidity treatment) |
- |
5000 |
|
- |
| 5(Marking) |
- |
1200 |
|
- |
| 6(Interchangeability) |
- |
1200 |
|
- |
| 7(Protection against accidental contact with live parts) |
- |
1200 |
|
- |
| 9(Mechanical strength) |
- |
1200 |
|
- |
| 10(Cap temperature rise) |
- |
2000 |
|
- |
| 11(Resistance to heat) |
- |
2000 |
|
- |
| 12(Resistance to flame and ignition) |
- |
5000 |
|
- |
| 13(Fault conditions) |
- |
2000 |
|
- |
| 14(Creepage distances and clearances) |
- |
1200 |
|
- |
| 15(Selection of lamps for tests (Sampling)) |
- |
0 |
|
- |
| 16(Condition of compliance) |
- |
0 |
|
- |
| 17(Tests) |
- |
0 |
|
- |
| Annex A(Ovreview of systems composed of LED modules and control gear) |
- |
0 |
|
- |
| Annex B(Lamps with operating position limitations) |
- |
0 |
|
- |
| 4(GENERAL REQUIREMENT AND GENERAL TEST REQUIREMENTS) |
- |
0 |
|
- |
|
14 Jun, 2027 |
- - |
| 509 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
| 6.0(Marking) |
- |
1200 |
|
- |
| 7.0(Construction) |
- |
1200 |
|
- |
| 8.0(Creepage Distance and Clearances) |
- |
1200 |
|
- |
| 9.0(Provision for earthing) |
- |
1200 |
|
- |
| 10.0(Terminals) |
- |
1200 |
|
- |
| 11.0(External & Internal Wiring) |
- |
1200 |
|
- |
| 12.0(Protection against electric shock) |
- |
1200 |
|
- |
| 13.0(Endurance Tests and Thermal Tests) |
- |
5500 |
|
- |
| 14.0(Resistance to Dust & Moisture) |
- |
12000 |
|
- |
| 15.0(Insulation Resistance and Electric Strength) |
- |
5000 |
|
- |
| 16.0(Resistance to Heat , fire and tracking) |
- |
12000 |
|
- |
| 17.0(Photometric Test) |
- |
10000 |
|
- |
| (Cl.4.24) (Annex-P)(UV Radiations for metal halide lamps) |
- |
0 |
|
- |
| 4.26.2(Short Circuit Protection) |
- |
0 |
|
- |
|
14 Jun, 2027 |
- - |
| 510 |
NATIONAL TEST HOUSE-ER (NTH), KOLKATA
| 5140804
| IS 16103 : Part 1 (2012) |
Led modules for general lighting: Part 1 safety requirements |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
500 |
|
NA |
| 8(Terminals) |
- |
500 |
|
NA |
| 9(PROVISION FOR EARTHING) |
- |
1000 |
|
NA |
| 10(Protection against accidental contact with live parts) |
- |
500 |
|
NA |
| 11(Mositure Resistance and Insulation) |
- |
3500 |
|
NA |
| 12(Electric Strength) |
- |
1500 |
|
NA |
| 13(Fault conditions) |
- |
1500 |
|
NA |
| 15(Construction) |
- |
500 |
|
NA |
| 16(Creepage distance and clearances) |
- |
500 |
|
NA |
| 17(Screws, current carrying parts and connections) |
- |
1000 |
|
NA |
| 18(Resistance to heat, fire and tracking) |
- |
12000 |
|
NA |
| 19(Resistance to corrosion) |
- |
2000 |
|
NA |
|
14 Jun, 2027 |
- - |