| 541 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 1077 (1992) |
Common burnt clay building bricks - Specification (Fifth Revision) |
- |
5000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Common burnt clay bricks) |
- |
500 |
|
- |
| 5(General Quality) |
- |
500 |
|
- |
| 6.1(Dimensions) |
- |
1000 |
|
- |
| 6.2(Tolerances) |
- |
1000 |
|
- |
| 7.1(Compressive strength) |
- |
2000 |
|
- |
| 7.2(Water Absorption) |
- |
1000 |
|
- |
| 7.3(Efflorescence) |
- |
1000 |
|
- |
| 9(Marking) |
- |
500 |
|
- |
|
28 Nov, 2028 |
- - |
| 542 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 12894 (2002) |
Pulverized fuel ash - Lime bricks - Specification |
- |
7000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(General Requirements) |
- |
500 |
|
- |
| 3.2(General Requirements) |
- |
500 |
|
- |
| 3.3(General Requirements) |
- |
500 |
|
- |
| 3.4(General Requirements) |
- |
500 |
|
- |
| 3.5(General Requirements) |
- |
500 |
|
- |
| 5.1(Dimensions) |
- |
500 |
|
- |
| 7.1, Table -1(Average Wet Compressive Strength) |
- |
2000 |
|
- |
| 7.2(Drying Shrinkage) |
- |
2000 |
|
- |
| 7.3(Efflorescence Test) |
- |
1000 |
|
- |
| 7.4(Water Absorption) |
- |
1000 |
|
- |
| 5.2(Tolerance) |
- |
500 |
|
- |
| 9(Marking) |
- |
500 |
|
- |
| 6(Materials) |
- |
500 |
|
- |
|
28 Nov, 2028 |
- - |
| 543 |
National Test House (NER) - NTH, Guwahati
| 5169204
| IS 1489 (Part 1) (2015) |
Portland pozzolana cement - Specification: Part 1 fly Ash Based |
PPC(FLY ASH BASED) |
13000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 - Table - 1 i(Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 ii(Magnesia - Cl 7.2 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 iv(Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
500 |
|
- |
| 6 - Table - 1 v(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
500 |
|
- |
| 6 - Table - 1 vi( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
2000 |
|
- |
| 7 -Table 2- i(Fineness 4031 Part 2) |
- |
1000 |
|
- |
| 7 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
500 |
|
- |
| 7 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
1000 |
|
- |
| 7 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 7 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 7 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 7 -Table 2- vi(Drying Shrinkage- IS 4031 Part 10) |
- |
1000 |
|
- |
| 7 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
500 |
|
- |
| 7 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
500 |
|
- |
|
13 Dec, 2027 |
- - |
| 544 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 1659 (2004) |
Block boards - Specification (Fourth Revision) |
- |
1100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.2.6(Spot test - Annexure L) |
- |
2000 |
|
- |
| 9.2.5(Modulus of elasticity - MINIMUM INDIVIDUAL - Annexure K) |
- |
2000 |
|
- |
| 9.2.5(Modulus of elasticity - AVERAGE - Annexure K) |
- |
2000 |
|
- |
| 9.2.5(Modulus of rupture - MINIMUM INDIVIDUAL - Annexure K) |
- |
2000 |
|
- |
| 9.2.5(Modulus of rupture - AVERAGE - Annexure K) |
- |
2000 |
|
- |
| 9.2.4(Mycological Test [for MR grade only] - Annexure J) |
- |
2000 |
|
- |
| 9.2.3(Adhesion of Plies - Annexure H) |
- |
2000 |
|
- |
| 9.2.2 (Resistance to water - Annexure G, Annexure H [For MR Grade]) |
- |
2000 |
|
- |
| 9.2.2 (Resistance to water - Annexure G, Annexure H [For BWP grade]) |
- |
2000 |
|
- |
| 9.2.1(Dimensional Changes caused by humidity Change in local planeness - Annexure F) |
- |
1000 |
|
- |
| 9.2.1(Dimensional Changes caused by humidity - Delamination - Annexure F) |
- |
1000 |
|
- |
| 9.2.1(Dimensional Changes caused by humidity - Change in thickness - at 40% RH - Annexure F) |
- |
1000 |
|
- |
| 9.2.1(Dimensional Changes caused by humidity - Change in Thickness - at 90% RH - Annexure F) |
- |
1000 |
|
- |
| 9.2.1(Dimensional Changes caused by humidity - Change in Length - at 40% RH - Annexure F) |
- |
1000 |
|
- |
| 9.2.1(Dimensional Changes caused by humidity - Change in Length - at 90% RH - Annexure F) |
- |
1000 |
|
- |
| 7.3(Dimensional Requirements - Variation in thickness - Annexure E) |
- |
1000 |
|
- |
| 7.3(Dimensional Requirements - Thickness - Annexure E) |
- |
1000 |
|
- |
| 7.3(Dimensional Requirements - Width - 8.1.4) |
- |
1000 |
|
- |
| 7.3(Dimensional Requirements - Length - 8.1.4) |
- |
1000 |
|
- |
| 8.1.3, 6.3.3, IS 1328(Visual Inspection - Permissible Defects - IS 1328 [test method for DECORATIVE type]) |
- |
1000 |
|
- |
| 8.1.3, 6.3.3, IS 303(Visual Inspection - Permissible Defects - IS 303 [test method for COMMERCIAL type]) |
- |
1000 |
|
- |
| 9.2.6 (mechanical)(Spot test - Annexure L) |
- |
2000 |
|
- |
| cl. 11(marking) |
- |
1000 |
|
- |
| cl. 11.1(marking - BIS certification marking) |
- |
1000 |
|
- |
| Cl-10(ADDITIONAL REQUIREMENTS FOR
ECO-MARK) |
- |
1000 |
|
- |
| 7.3(Dimensional Requirements - Squareness - Annexure D) |
- |
1000 |
|
- |
| 7.3(Dimensional Requirements - Edge Straightness - Annexure D) |
- |
1000 |
|
- |
|
28 Nov, 2028 |
- - |
| 545 |
National Test House (NER) - NTH, Guwahati
| 5169204
| IS 269 (2015) |
Ordinary portland cement - Specification (Sixth Revision) |
OPC 33/43/ 53 Grade,OPC 43S & 53S Grade |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1 Table-2 vii(Chloride content) |
- |
500 |
|
- |
| 6.1 Table-2 viii(Alkali content) |
- |
2000 |
|
- |
| 6.1 Table-2 vi(Loss on ignition) |
- |
500 |
|
- |
| 6.1 Table-2 v(Total Sulphur Content calculated as Sulphuric Anhydride) |
- |
1000 |
|
- |
| 6.1 Table-2 iv(Magnesia) |
- |
1000 |
|
- |
| 6 - Table - 1 iii(Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
1000 |
|
- |
| 6.1 Table-2 ii.(Ratio of percentage of alumina to that of iron oxide) |
- |
1000 |
|
- |
| 6.1 Table-2 i.(Ratio of percentage of lime to percentage of silica, alumina and iron oxide) |
- |
1000 |
|
- |
| 7 Table-3 i.(Fineness) |
- |
1000 |
|
- |
| 7 Table-3 ii a(Expansion by Le Chatelier) |
- |
500 |
|
- |
| 7 Table-3 ii b(Expansion by Autoclave) |
- |
1000 |
|
- |
| 7 Table-3 iii a(Setting Time Initial) |
- |
500 |
|
- |
| 7 Table-3 iii b(Setting Time Final) |
- |
500 |
|
- |
| 7 Table-3 iv a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 7 Table-3 iv b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 7 Table-3 iv c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
|
13 Dec, 2027 |
- - |
| 546 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 8042 (2015) |
White portland cement - Specification (Third Revision) |
- |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5 - Table - 1 i(Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
1000 |
|
- |
| 5 - Table - 1 ii(Iron oxide - Cl 4.5 of IS 4032:1985) |
- |
1200 |
|
- |
| 5 - Table - 1 iii(Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
1200 |
|
- |
| 5 - Table - 1 iv(Magnesia - Cl 4.8 of IS 4032:1985) |
- |
1200 |
|
- |
| 5 - Table - 1 v(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
1200 |
|
- |
| 5 - Table - 1 vi(Loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
1200 |
|
- |
| 5 - Table - 1 vii(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
1200 |
|
- |
| 6 -Table 2- i(Fineness 4031 Part 2) |
- |
1000 |
|
- |
| 6 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
500 |
|
- |
| 6 -Table 2- ii- a(Expansion after aeration - 4031 Part 3) |
- |
500 |
|
- |
| 6 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
500 |
|
- |
| 6-Table 2- ii- b(Expansion after aeration- 4031 Part 3) |
- |
500 |
|
- |
| 6 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
500 |
|
- |
| 6 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
500 |
|
- |
| 6 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 6 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 6 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 6 -Table 2- v(Transverse Strength - IS 4031 Part 8 (Optional)) |
- |
2000 |
|
- |
| 6 -Table 2- vi(Degree of whiteness-Annex B) |
- |
1500 |
|
- |
| 5 - Table - 1 i(Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
1000 |
|
- |
| 5 - Table - 1 ii(Iron oxide - Cl 4.5 of IS 4032:1985) |
- |
1200 |
|
- |
| 5 - Table - 1 iii(Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
1200 |
|
- |
| 5 - Table - 1 iv(Magnesia - Cl 4.8 of IS 4032:1985) |
- |
1200 |
|
- |
| 5 - Table - 1 v(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
1200 |
|
- |
| 5 - Table - 1 vi(Loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
1200 |
|
- |
| 5 - Table - 1 vii(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
1200 |
|
- |
| 6 -Table 2- i(Fineness 4031 Part 2) |
- |
1000 |
|
- |
| 6 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
500 |
|
- |
| 6 -Table 2- ii- a(Expansion after aeration - 4031 Part 3) |
- |
500 |
|
- |
| 6 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
1000 |
|
- |
| 6-Table 2- ii- b(Expansion after aeration- 4031 Part 3) |
- |
500 |
|
- |
| 6 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
500 |
|
- |
| 6 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
500 |
|
- |
| 6 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 6 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 6 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 6 -Table 2- v(Transverse Strength - IS 4031 Part 8 (Optional)) |
- |
2000 |
|
- |
| 6 -Table 2- vi(Degree of whiteness-Annex B) |
- |
1500 |
|
- |
| 6, table-2, ii(Whiteness) |
- |
1500 |
|
- |
| Clause 6
Table 2, SI No. (v)
(Compressive strength of Transverse Specimen, 672 ± 4 h) |
- |
1000 |
|
- |
| Clause 6
Table 2, SI No. (v)
(Compressive strength of Transverse Specimen, 168 ± 2 h) |
- |
1000 |
|
- |
| Clause 6
Table 2, SI No. (v)
(Compressive strength of Transverse Specimen, 72 ± 1 h) |
- |
1000 |
|
- |
| Clause 6
Table 2, SI No. (v)
(Transverse Strength, 672 ± 4 h) |
- |
2000 |
|
- |
| Clause 6
Table 2, SI No. (v)
(Transverse Strength, 168 ± 2 h) |
- |
2000 |
|
- |
| Clause 6
Table 2, SI No. (v)
(Transverse Strength, 72 ± 1 h) |
- |
2000 |
|
- |
|
28 Nov, 2028 |
- - |
| 547 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 1489 (Part 1) (2015) |
Portland pozzolana cement - Specification: Part 1 fly Ash Based |
- |
10500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 - Table - 1 i(Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
1180 |
|
ALL FEES ARE INCLUDING GST |
| 6 - Table - 1 ii(Magnesia - Cl 7.2 of IS 4032:1985) |
- |
1180 |
|
ALL FEES ARE INCLUDING GST |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
1180 |
|
ALL FEES ARE INCLUDING GST |
| 6 - Table - 1 iv(Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
1180 |
|
ALL FEES ARE INCLUDING GST |
| 6 - Table - 1 v(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
1180 |
|
ALL FEES ARE INCLUDING GST |
| 6 - Table - 1 vi( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
1180 |
|
ALL FEES ARE INCLUDING GST |
| 7 -Table 2- vi(Drying Shrinkage- IS 4031 Part 10) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
| 7 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
| 7 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
| 7 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
| 7 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
590 |
|
ALL FEES ARE INCLUDING GST |
| 7 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
590 |
|
ALL FEES ARE INCLUDING GST |
| 7 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
1118 |
|
- |
| 7 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
590 |
|
ALL FEES ARE INCLUDING GST |
| 7 -Table 2- i(Fineness 4031 Part 2) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
|
28 Nov, 2028 |
- - |
| 548 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 14276 (2016) |
Cement bonded particle boards - Specification (First Revision) |
- |
7000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Finish) |
- |
500 |
|
- |
| 7(Dimensions and Tolerances) |
- |
500 |
|
- |
| 8.5(Workability) |
- |
500 |
|
- |
| 10.3, Table-1(Test for Density) |
- |
1000 |
|
- |
| 10.5, Table-1(Test for Water Absorption) |
- |
1000 |
|
- |
| 10.6, Table-1(Test for swelling in water) |
- |
1000 |
|
- |
| 10.7, Table-1(Test for modulus of Rupture) |
- |
1000 |
|
- |
| 10.8, Table-1(Test for modulus of Elasticity) |
- |
1000 |
|
- |
| 10.9, Table-1(Test for tensile strength perpendicular to Surface) |
- |
2000 |
|
- |
| 10.1, Table-1(Test for Screw Withdrawal Strength) |
- |
1500 |
|
- |
| Clause 8.2 Table 1(Moisture content) |
- |
1000 |
|
- |
|
28 Nov, 2028 |
- - |
| 549 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 1130 (1969) |
Marble (blocks, Slabs And Tiles) |
- |
5000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Requirements) |
- |
500 |
|
- |
| 5(Sizes) |
- |
1000 |
|
- |
| 6(Tolerance) |
- |
500 |
|
- |
| 7.1-Table 1-(i)(Moisture absorption after 24 hours immersion in cold water) |
- |
1000 |
|
- |
| 7.1-Table 1-(ii)(Hardness) |
- |
2000 |
|
- |
| 7.1-Table 1-(iii)(Specific gravity) |
- |
1000 |
|
- |
| 8(Workmanship) |
- |
500 |
|
- |
| 9(Marking) |
- |
500 |
|
- |
|
28 Nov, 2028 |
- - |
| 550 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 3316 (1974) |
Structural Granite |
- |
5000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2(General Requirements) |
- |
1000 |
|
- |
| 3(Strength Requirements) |
- |
5000 |
|
- |
| 4.1(Slabs) |
- |
500 |
|
- |
| 4.2(Blocks for Masonry) |
- |
500 |
|
- |
| 5(Marking) |
- |
500 |
|
- |
|
28 Nov, 2028 |
- - |
| 551 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 16415 (2015) |
Composite cement - Specification |
- |
10500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Chemical Requirements) |
- |
3500 |
|
- |
| 7(Physical Requirement) |
- |
7000 |
|
- |
| 6 -Table - 2 i(Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
1200 |
|
- |
| 6 -Table - 2 ii(Magnesia - Cl 4.8 of IS 4032:1985) |
- |
1200 |
|
- |
| 6 -Table - 2 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
1200 |
|
- |
| 6 -Table - 2 iv(Sulphide sulphur (S) - Cl 6.12 of IS 4032:1985) |
- |
1200 |
|
- |
| 6 -Table - 2 v(Loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
1200 |
|
- |
| 6 -Table - 2 vi(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
1200 |
|
- |
| 7 and Table 3 i(Fineness
IS 4031(Part 2)) |
- |
1000 |
|
- |
| 7 and Table 3 ii a(Soundness, Le-Chate1ier expansion
IS 4031(Part 3) ) |
- |
500 |
|
- |
| 7 and Table 3 ii b(Soundness, Autoclave expansion
IS 4031(Part 3) ) |
- |
1000 |
|
- |
| 7 and Table 3 iii a(Setting Time ( by Vicat Apparatus), Initial
IS 4031(Part 5)) |
- |
500 |
|
- |
| 7 and Table 3 iii b(Setting Time ( by Vicat Apparatus ), Final
IS 4031(Part 5)) |
- |
500 |
|
- |
| 7 and Table 3 iv a(Compretsive Strenqth .72 ± 1 hr
IS 4031(Part 6)) |
- |
1000 |
|
- |
| 7 and Table 3 iv b(Compretsive Strenqth 168 ± 2 hr
IS 4031(Part 6)) |
- |
1000 |
|
- |
| 7 and Table 3 iv c(Compretsive Strenqth 672 ± 4 hr
IS 4031(Part 6)) |
- |
1000 |
|
- |
| 7 and Table 3 v(Drying shrinkage
IS 4031(Part 10)) |
- |
1000 |
|
- |
| 7 and Table 3 vi(Transverse strength (optional)
IS 4031(Part 8) ) |
- |
2000 |
|
- |
| 6 -Table - 2 i(Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
1200 |
|
- |
| 6 -Table - 2 ii(Magnesia - Cl 4.8 of IS 4032:1985) |
- |
1200 |
|
- |
| 6 -Table - 2 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
1200 |
|
- |
| 6 -Table - 2 iv(Sulphide sulphur (S) - Cl 6.12 of IS 4032:1985) |
- |
1200 |
|
- |
| 6 -Table - 2 v(Loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
1200 |
|
- |
| 6 -Table - 2 vi(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
1200 |
|
- |
| 7 and Table 3 i(Fineness
IS 4031(Part 2)) |
- |
1000 |
|
- |
| 7 and Table 3 ii a(Soundness, Le-Chate1ier expansion
IS 4031(Part 3) ) |
- |
500 |
|
- |
| 7 and Table 3 ii b(Soundness, Autoclave expansion
IS 4031(Part 3) ) |
- |
1000 |
|
- |
| 7 and Table 3 iii a(Setting Time ( by Vicat Apparatus), Initial
IS 4031(Part 5)) |
- |
500 |
|
- |
| 7 and Table 3 iii b(Setting Time ( by Vicat Apparatus ), Final
IS 4031(Part 5)) |
- |
500 |
|
- |
| 7 and Table 3 iv a(Compretsive Strenqth .72 ± 1 hr
IS 4031(Part 6)) |
- |
1000 |
|
- |
| 7 and Table 3 iv b(Compretsive Strenqth 168 ± 2 hr
IS 4031(Part 6)) |
- |
1000 |
|
- |
| 7 and Table 3 iv c(Compretsive Strenqth 672 ± 4 hr
IS 4031(Part 6)) |
- |
1000 |
|
- |
| 7 and Table 3 v(Drying shrinkage
IS 4031(Part 10)) |
- |
1000 |
|
- |
| 7 and Table 3 vi(Transverse strength (optional)
IS 4031(Part 8) ) |
- |
2000 |
|
- |
| Cl. 6.1,Table 2(Alkali content) |
- |
1200 |
|
- |
| Cl. 6.1,Table 2(Chloride content) |
- |
1200 |
|
- |
| Cl. 6.1,Table 2(Loss on ignition) |
- |
1200 |
|
- |
| Cl. 6.1,Table 2(Suilphide sulphur) |
- |
1200 |
|
- |
| Cl. 6.1,Table 2(Total sulphur content calculated as sulphuric anhydride) |
- |
1200 |
|
- |
| Cl. 6.1,Table 2(Magnesia) |
- |
1200 |
|
- |
| Cl. 6.1,Table 2(Insoluble residue) |
- |
1200 |
|
- |
|
28 Nov, 2028 |
- - |
| 552 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 269 (2015) |
Ordinary portland cement - Specification (Sixth Revision) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 Table-3 iv c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
| 7 Table-3 iv b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
| 7 Table-3 iv a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
| 7 Table-3 iii b(Setting Time Final) |
- |
590 |
|
ALL FEES ARE INCLUDING GST |
| 7 Table-3 iii a(Setting Time Initial) |
- |
590 |
|
ALL FEES ARE INCLUDING GST |
| 7 Table-3 ii b(Expansion by Autoclave) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
| 7 Table-3 ii a(Expansion by Le Chatelier) |
- |
590 |
|
ALL FEES ARE INCLUDING GST |
| 7 Table-3 i.(Fineness) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
| 6.1 Table-2 i.(Ratio of percentage of lime to percentage of silica, alumina and iron oxide) |
- |
0 |
|
- |
| 6.1 Table-2 ii.(Ratio of percentage of alumina to that of iron oxide) |
- |
0 |
|
- |
| 6.1 Table-2 iii.(Insoluble residue) |
- |
0 |
|
- |
| 6 - Table - 1 iv(Magnesia - Cl 4.8 of IS 4032:1985) |
- |
0 |
|
- |
| 6.1 Table-2 v(Total Sulphur Content calculated as Sulphuric Anhydride) |
- |
0 |
|
- |
| 6.1 Table-2 vi(Loss on ignition) |
- |
0 |
|
- |
| 6.1 Table-2 vii(Chloride content) |
- |
0 |
|
- |
| 6.1 Table-2 viii(Alkali content) |
- |
0 |
|
- |
|
28 Nov, 2028 |
- - |
| 553 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 455 (2015) |
Portland slag cement - Specification |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 Table 1 iv c(Compretsive Strenqth 672 ± 4 hr
IS 4031(Part 6)) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
| 7 Table 1 iv b(Compretsive Strenqth 168 ± 2 hr
IS 4031(Part 6)) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
| 7 Table 1 iv a(Compretsive Strenqth .72 ± 1 hr
IS 4031(Part 6)) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
| 7 Table 1 iii b(Setting Time ( by Vicat Apparatus ), Final
IS 4031(Part 5)) |
- |
590 |
|
ALL FEES ARE INCLUDING GST |
| 7 Table 1 iii a(Setting Time ( by Vicat Apparatus ),Initial
IS 4031(Part 5)) |
- |
590 |
|
ALL FEES ARE INCLUDING GST |
| 7 Table 1 ii b(Soundness, Autoclave expansion
IS 4031(Part 3) ) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
| 7 Table 1 ii a(Soundness, Le-Chate1ier expansion
IS 4031(Part 3) ) |
- |
590 |
|
ALL FEES ARE INCLUDING GST |
| 7 Table 1 i(Fineness
IS 4031(Part 2)) |
- |
1118 |
|
ALL FEES ARE INCLUDING GST |
| 6 - Table - 1 i(Insoluble residue - Cl 6.9 of IS 4032:1985) |
- |
0 |
|
- |
| 6 - Table - 1 ii(Magnesia - Cl 6.8 of IS 4032:1985) |
- |
0 |
|
- |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 6.11 of IS 4032:1985) |
- |
0 |
|
- |
| 6 - Table - 1 iv(Sulphide sulphur (S) - Cl 6.12 of IS 4032:1985) |
- |
0 |
|
- |
| 6 - Table - 1 v(Loss on ignition - Cl 6.2 of IS 4032:1985) |
- |
0 |
|
- |
| 6 - Table - 1 vi(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
0 |
|
- |
| 6 - Table - 1 vii( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
0 |
|
- |
|
28 Nov, 2028 |
- - |
| 554 |
National Test House (NER) - NTH, Guwahati
| 5169204
| IS 455 (2015) |
Portland slag cement - Specification |
Portland Slag Cement |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 Table 1 iv c(Compretsive Strenqth 672 ± 4 hr
IS 4031(Part 6)) |
- |
1000 |
|
- |
| 7 Table 1 iv b(Compretsive Strenqth 168 ± 2 hr
IS 4031(Part 6)) |
- |
1000 |
|
- |
| 7 Table 1 iv a(Compretsive Strenqth .72 ± 1 hr
IS 4031(Part 6)) |
- |
1000 |
|
- |
| 7 Table 1 iii b(Setting Time ( by Vicat Apparatus ), Final
IS 4031(Part 5)) |
- |
500 |
|
- |
| 7 Table 1 iii a(Setting Time ( by Vicat Apparatus ),Initial
IS 4031(Part 5)) |
- |
500 |
|
- |
| 7 Table 1 ii b(Soundness, Autoclave expansion
IS 4031(Part 3) ) |
- |
1000 |
|
- |
| 7 Table 1 ii a(Soundness, Le-Chate1ier expansion
IS 4031(Part 3) ) |
- |
500 |
|
- |
| 7 Table 1 i(Fineness
IS 4031(Part 2)) |
- |
1000 |
|
- |
| 6 - Table - 1 i(Insoluble residue - Cl 6.9 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 ii(Magnesia - Cl 6.8 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 6.11 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 iv(Sulphide sulphur (S) - Cl 6.12 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 v(Loss on ignition - Cl 6.2 of IS 4032:1985) |
- |
500 |
|
- |
| 6 - Table - 1 vi(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
500 |
|
- |
| 6 - Table - 1 vii( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
2000 |
|
- |
|
13 Dec, 2027 |
- - |
| 555 |
National Test House (NER) - NTH, Guwahati
| 5169204
| IS 16415 (2015) |
Composite cement - Specification |
Composite Cement |
13000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 and Table 3 i(Fineness
IS 4031(Part 2)) |
- |
1000 |
|
- |
| 7 and Table 3 ii a(Soundness, Le-Chate1ier expansion
IS 4031(Part 3) ) |
- |
500 |
|
- |
| 7 and Table 3 ii b(Soundness, Autoclave expansion
IS 4031(Part 3) ) |
- |
1000 |
|
- |
| 7 and Table 3 iii a(Setting Time ( by Vicat Apparatus), Initial
IS 4031(Part 5)) |
- |
500 |
|
- |
| 7 and Table 3 iii b(Setting Time ( by Vicat Apparatus ), Final
IS 4031(Part 5)) |
- |
500 |
|
- |
| 7 and Table 3 iv a(Compretsive Strenqth .72 ± 1 hr
IS 4031(Part 6)) |
- |
1000 |
|
- |
| 7 and Table 3 iv b(Compretsive Strenqth 168 ± 2 hr
IS 4031(Part 6)) |
- |
1000 |
|
- |
| 7 and Table 3 iv c(Compretsive Strenqth 672 ± 4 hr
IS 4031(Part 6)) |
- |
1000 |
|
- |
| 7 and Table 3 v(Drying shrinkage
IS 4031(Part 10)) |
- |
1000 |
|
- |
| 6 -Table - 2 i(Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 -Table - 2 ii(Magnesia - Cl 4.8 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 -Table - 2 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 -Table - 2 iv(Sulphide sulphur (S) - Cl 6.12 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 -Table - 2 v(Loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
500 |
|
- |
| 6 -Table - 2 vi(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
500 |
|
- |
|
13 Dec, 2027 |
- - |
| 556 |
National Test House (NER) - NTH, Guwahati
| 5169204
| IS 1489 : Part 2 (2015) |
Portland - Pozzolana cement - Specification: Part 2 calcined clay based |
PPC(CALCINED CLAY BASED) |
13000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 - Table - 1 i(Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 ii(Magnesia - Cl 7.2 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
1000 |
|
- |
| 6 - Table - 1 iv(Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
500 |
|
- |
| 6 - Table - 1 v(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
500 |
|
- |
| 6 - Table - 1 vi( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
2000 |
|
- |
| 7 -Table 2- i(Fineness 4031 Part 2) |
- |
1000 |
|
- |
| 7 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
500 |
|
- |
| 7 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
1000 |
|
- |
| 7 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
500 |
|
- |
| 7 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
500 |
|
- |
| 7 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 7 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 7 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
1000 |
|
- |
| 7 -Table 2- vi(Drying Shrinkage- IS 4031 Part 10) |
- |
1000 |
|
- |
|
13 Dec, 2027 |
- - |
| 557 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 4250 (1980) |
Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
500 |
|
- |
| 6(Classification- IS 302-1) |
- |
499.99 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
499.99 |
|
- |
| 7.2(Marking) |
- |
500 |
|
- |
| 7.4(Marking) |
- |
500 |
|
- |
| 7.5(Marking) |
- |
500 |
|
- |
| 7.6(Marking) |
- |
500 |
|
- |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
500 |
|
- |
| 9(Starting, IS 302-1) |
- |
1000 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
1000 |
|
- |
| 11(Heating, IS 302-1) |
- |
1000 |
|
- |
| 11(Heating, IS 302-1) |
- |
1000 |
|
- |
| 11(Heating, IS 302-1) |
- |
1000 |
|
- |
| 11(Heating, IS 302-1) |
- |
1000 |
|
- |
| 11(Heating, IS 302-1) |
- |
1000 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1500 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
1500 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
1500 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1500 |
|
- |
| 19(Abnormal Operation, IS 302-1) |
- |
1500 |
|
- |
| 20(Stability & Mechanical Hazards, IS 302-1) |
- |
1500 |
|
- |
| 21(Mechanical Strength, IS 302-1) |
- |
1000 |
|
- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 27(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
1000 |
|
- |
| 29(Clearances and Distances through Insulation, IS 302-1) |
- |
1000 |
|
- |
| 30(Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
1500 |
|
- |
| 22.2(Construction) |
- |
500 |
|
- |
| 34.2(Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
2000 |
|
- |
| 34.3(Whisking egg whites ) |
- |
1500 |
|
- |
| 34.4(IDLI batter-Grinding of black gram) |
- |
1000 |
|
- |
| 34.4(IDLI batter-Grinding of rice) |
- |
1000 |
|
- |
| 34.5.1 (a)(Operational test for juicers ) |
- |
1000 |
|
- |
| 37(Strength of Assembly ) |
- |
1000 |
|
- |
|
28 Nov, 2028 |
- - |
| 558 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
Earthed & Unearthed upto 1.1kV and DC upto 1.5kV |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(MATERIALS : CONDUCTOR) |
- |
1000 |
|
- |
| 4.1.1(INSULATION : General Purjose Insulaiion) |
- |
500 |
|
- |
| 4.1.2(INSULATION : Heat Resisting Insulation) |
- |
500 |
|
- |
| 5.1(MATERIALS : FILLER AND INNER SHEATH) |
- |
500 |
|
- |
| 5.2(MATERIALS : FILLER AND INNER SHEATH) |
- |
500 |
|
- |
| 8.1(CONSTRUCTION : CONDUCTOR) |
- |
500 |
|
- |
| 8.2(CONSTRUCTION : CONDUCTOR) |
- |
500 |
|
- |
| 9.2(INSULATION : Thickness of Insulation) |
- |
500 |
|
- |
| 9.3(INSULATION :Tolerance on Thickness of Insulation) |
- |
500 |
|
- |
| 9.4(INSULATION : Application of Insulation) |
- |
500 |
|
- |
| 10.1(CORE IDENTIFICATION) |
- |
500 |
|
- |
| 10.2(CORE IDENTIFICATION) |
- |
500 |
|
- |
| 10.3(CORE IDENTIFICATION) |
- |
500 |
|
- |
| 11.1(LAYING UP OF CORES) |
- |
500 |
|
- |
| 11.2(LAYING UP OF CORES) |
- |
500 |
|
- |
| 12.1(INNER SHEATH) |
- |
500 |
|
- |
| 12.2(INNER SHEATH) |
- |
500 |
|
- |
| 12.3(INNER SHEATH :Thickness of Inner Sheath) |
- |
500 |
|
- |
| 12.3.1(INNER SHEATH :Thickness of Inner Sheath) |
- |
500 |
|
- |
| 13.1.1(ARMOURING : Application) |
- |
500 |
|
- |
| 13.1.2(Armouring: Coverage ) |
- |
500 |
|
- |
| 13.3(Armouring : Dimensions -Wire Diameter) |
- |
1000 |
|
- |
| 13.4(ARMOURING : Joints) |
- |
1000 |
|
- |
| 13.5.1(ARMOURING : Resistance) |
- |
1000 |
|
- |
| 13.5.2(ARMOURING : Resistance) |
- |
1000 |
|
- |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
1000 |
|
- |
| 13.6 b)(ARMOURING: Elongation ) |
- |
1000 |
|
- |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
1000 |
|
- |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
1000 |
|
- |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
1000 |
|
- |
| 13.6 g)(ARMOURING: Resistivity) |
- |
1000 |
|
- |
| 14.1(OUTER SHEATH) |
- |
1000 |
|
- |
| 14.3(OUTER SHEATH : Colour ) |
- |
1000 |
|
- |
| 14.4.1(Thickness of Outer Sheath : Unarmowed Cables) |
- |
1000 |
|
- |
| 14.4.2(Thickness of Outer Sheath : Armoured Cables) |
- |
1000 |
|
- |
| 15.1 a) 1)(Tests on conductor : Annealing test ( for copper )) |
- |
1000 |
|
- |
| 15.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
1000 |
|
- |
| 15.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
1000 |
|
- |
| 15.1 a) 3)(Tests on conductor : Wrapping test ( for aluminium )) |
- |
1000 |
|
- |
| 15.1 a) 4)(Tests on conductor : Conductor resistance test) |
- |
1000 |
|
- |
| 15.1 a) 4)(Resistance test - Neutral conductor ) |
- |
1000 |
|
- |
| 15.1 d)1)(Phyaical tests for insulation : Tensile Test) |
- |
1000 |
|
- |
| 15.1 d)1)(Phyaical tests for insulation : Elongation ) |
- |
1000 |
|
- |
| 15.1 d)2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
1000 |
|
- |
| 15.1 d)2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
1000 |
|
- |
| 15.1 d)2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
1000 |
|
- |
| 15.1 d)2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
1000 |
|
- |
| 15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
1000 |
|
- |
| 15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
1000 |
|
- |
| 15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
1000 |
|
- |
| 15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
1000 |
|
- |
| 15.1 d)3)(Phyaical tests for Sheath : Shrinkage ) |
- |
1000 |
|
- |
| 15.1 d)4)(Hot deformation : Insulation ) |
- |
1000 |
|
- |
| 15.1 d)4)(Hot deformation : Sheath ) |
- |
1000 |
|
- |
| 15.1 d)5)( Loss of mass in air oven- Insulation ) |
- |
1000 |
|
- |
| 15.1 d)5)( Loss of mass in air oven- sheath ) |
- |
1000 |
|
- |
| 15.1 d)6)(Heat shock test- Insulation ) |
- |
1000 |
|
- |
| 15.1 d)7)(Thermal stability- insulation ) |
- |
1000 |
|
- |
| 15.1 d)7)(Thermal stability- Sheath ) |
- |
1000 |
|
- |
| 15.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
1000 |
|
- |
| 15.1 e)(Insulation resistance test : IR Constant ) |
- |
1000 |
|
- |
| 15.1 f)(High voltage test ( water immersion test )) |
- |
1000 |
|
- |
| 15.1 g)(High voltage test at room temperature) |
- |
1000 |
|
- |
| 15.4 a)(Cold bend test- Insulation ( Optional test)) |
- |
1000 |
|
- |
| 15.4 a)(Cold bend test- Sheath ( Optional test)) |
- |
1000 |
|
- |
| 15.4 b)(Cold impact test- Sheath ( Optional test)) |
- |
1000 |
|
- |
| 15.4 b)(Cold impact test- Insulation ( Optional test)) |
- |
1000 |
|
- |
| 16.2(DETAILS OF TESTS : High Voltage Test at Room Temperature) |
- |
1000 |
|
- |
| 16.3.1(High Voltage Test ( Water Immersion Test ) : a.c. Test) |
- |
1000 |
|
- |
| 16.3.2(High Voltage Test ( Water Immersion Test ) : d.c. Test) |
- |
1000 |
|
- |
| 16.4(Flammability Test) |
- |
1000 |
|
- |
| 16.5(Oxygen Index Test) |
- |
5000 |
|
- |
| 16.6(Flame Retardance Test on Single Cables) |
- |
1000 |
|
- |
| 16.9(Test for Halogen Acid Gas Evolution) |
- |
5000 |
|
- |
| 16.1(Temperature Index) |
- |
5000 |
|
- |
| Cl No. 16.10(Smoke density test) |
- |
5000 |
|
- |
| Table 4(Copper purity test) |
- |
1000 |
|
- |
| 16.4(Flammability Test- Un affected portion) |
- |
1000 |
|
- |
| 15.1.e(Insulation resistance Test- Volume Resistivity At Room temperature) |
- |
1000 |
|
- |
|
28 Nov, 2028 |
- - |
| 559 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 398 : Part 2 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
Aluminum conductors, galvanized steel reinforced |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires Before Stranding) |
- |
600 |
|
- |
| 8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires Before Stranding) |
- |
600 |
|
- |
| 8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires After Stranding) |
- |
600 |
|
- |
| 8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires After Stranding) |
- |
599.98 |
|
- |
| 13.3 Table 1 (mech)(Breaking Load of Aluminium Wires Before Stranding) |
- |
999.99 |
|
- |
| 13.3 Table 2 (mech)(Breaking Load of Steel Wires Before Stranding) |
- |
999.99 |
|
- |
| 13.3 Table 1 (mech)(Breaking Load of Aluminium Wires After Stranding) |
- |
1000 |
|
- |
| 13.3 Table 2 (mech)(Breaking Load of Steel Wires After Stranding) |
- |
1000 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
1000 |
|
- |
| 13.5.1 (mech)(Wrapping Test Aluminium Wires Before Stranding) |
- |
599.99 |
|
- |
| 13.6 (elec)(Resistance test-Aluminium wire before Stranding) |
- |
1000 |
|
- |
| 13.5.1 (mech)(Wrapping Test Aluminium Wires After Stranding) |
- |
600 |
|
- |
| 13.5.2 (mech)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
600 |
|
- |
| 13.6 (elec)(Resistance test-Aluminium wire after stranding) |
- |
1000 |
|
- |
| 13.7.2 (chem)(Mass of Zinc coating) |
- |
600 |
|
- |
| 13.7.2 (chem)(Uniformity of Zinc coating) |
- |
600 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
600 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
600 |
|
- |
| 13.10 (elec)(Ultimate breaking load) |
- |
10000 |
|
- |
| 13.11 (elec)(Stress-strain test) |
- |
10000 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test after stranding) |
- |
600 |
|
- |
| 13.3 Table 2 (elec)(Breaking Load of Steel Wires After Stranding) |
- |
1000 |
|
- |
| 13.3 Table 1 (elec)(Breaking Load of Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table 2 (elec)(Diameter of Steel Wires After Stranding) |
- |
600 |
|
- |
| 8.1.1 & 13.2 Table-1 (elec)(Diameter of Aluminium Wires After Stranding) |
- |
600 |
|
- |
|
28 Nov, 2028 |
- - |
| 560 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 398 : Part 1 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) |
Al stranded Conductors & Accessories for Overhead line |
5625 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 12.2, Table-1(Measurement of diameter of individual aluminium wire) |
- |
600 |
|
- |
| 12.3, Table-1(Breaking load before stranding) |
- |
1500 |
|
- |
| 12.3, Table-1(Breaking load after stranding) |
- |
1500 |
|
- |
| 12.4(Wrapping test) |
- |
1000 |
|
- |
| 12.5, Table 1(Resistance test) |
- |
1000 |
|
- |
| 12.6, Table 3(Measurement of lay ratio) |
- |
1000 |
|
- |
| 6(Freedom from defects) |
- |
500 |
|
- |
|
28 Nov, 2028 |
- - |
| 561 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Conductor - Material) |
- |
1000 |
|
- |
| 5.1(Insulation) |
- |
500 |
|
- |
| 5.2(Application ) |
- |
500 |
|
- |
| 12(CONSTRUCTION Core Identification) |
- |
500 |
|
- |
| 4.2(Conductor resistance test) |
- |
500 |
|
- |
| Table 1 iii) c) 1)(Elongation (Without ageing)) |
- |
500 |
|
- |
| Table 1 iii) c) 1)(Tensile strength (Without ageing)) |
- |
500 |
|
- |
| Table 1 iii) d) 2)(Loss of mass- Sheath ) |
- |
500 |
|
- |
| Table 1 iii) c) 2)(Loss of mass- Insulation ) |
- |
500 |
|
- |
| Table 1 iii) c) 3)(Elongation variation) |
- |
500 |
|
- |
| Table 1 iii) c) 3)(TS variation) |
- |
500 |
|
- |
| Table 1 iii) c) 3)(Elongation (After ageing)) |
- |
500 |
|
- |
| Table 1 iii) c) 3)(Tensile strength (After ageing)) |
- |
500 |
|
- |
| Table 1 iii) d) 3)(Sheath- Elongation variation) |
- |
500 |
|
- |
| Table 1 iii) d) 3)(Sheath- TS variation) |
- |
500 |
|
- |
| Table 1 iii) d) 3)(Sheath- Elongation (After ageing)) |
- |
500 |
|
- |
| Table 1 iii) d) 3)(Sheath- Tensile strength (After ageing)) |
- |
500 |
|
- |
| Table 1 iii) d) 1)(Sheath- Elongation (Without ageing)) |
- |
500 |
|
- |
| Table 1 iii) d) 1)(Sheath -Tensile strength (Without ageing)) |
- |
500 |
|
- |
| Table 1 iii) d) 7)(Thermal stability- Sheath ) |
- |
500 |
|
- |
| Table 1 iii) c) 7)(Thermal stability- Insulation ) |
- |
500 |
|
- |
| Table 1 iii) d) 6)(Hot deformation -Indentation depth - Sheath ) |
- |
500 |
|
- |
| Table 1 iii) c) 6)(Hot deformation - Indentation depth- Insulation) |
- |
500 |
|
- |
| Table 1 iii) c) 4)(Shrinkage-Insulation) |
- |
500 |
|
- |
| Table 1 iii) d) 4)(Shrinkage- Sheath ) |
- |
500 |
|
- |
| Table 1 iii) d) 5)(Heat shock-Sheath ) |
- |
500 |
|
- |
| Table 1 iii) c) 5)(Heat shock-Insulation ) |
- |
500 |
|
- |
| 10.4(Flammability test- Unaffected portion) |
- |
500 |
|
- |
| 10.4(Flammability test-Burning after flame removal) |
- |
500 |
|
- |
| 4.1(Annealing test (for copper)) |
- |
500 |
|
- |
| 4.1(Wrapping test (for Al)) |
- |
500 |
|
- |
| 4.1(Tensile test (for Al)- After Stranding) |
- |
500 |
|
- |
| 4.1(Tensile test (for Al)-Before Stranding) |
- |
500 |
|
- |
| 10.11(Per sulphate test (for tinned Cu cable only)) |
- |
500 |
|
- |
| Table 1 iii) c) 8)(Cold bend for insulation) |
- |
500 |
|
- |
| Table 1 iii) d) 8)(Cold bend for sheath) |
- |
500 |
|
- |
| Table 1 iii) c) 9)(Cold impact for insulation) |
- |
500 |
|
- |
| Table 1 iii) d) 9)(Cold impact for sheath) |
- |
500 |
|
- |
| 10.9(Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
500 |
|
- |
| 10.5(Oxygen index) |
- |
5000 |
|
- |
| 10.7(Temperature index) |
- |
5000 |
|
- |
| 10.6(Halogen evolution) |
- |
5000 |
|
- |
| 10.8(Smoke density rating) |
- |
5000 |
|
- |
| table 1 e) 3) (IR constant- max. Temp) |
- |
500 |
|
- |
| table 1 e) 3) (IR constant- Room temp ) |
- |
500 |
|
- |
| table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
500 |
|
- |
| table 1 e) 3) (Volume Resistivity - Room temp ) |
- |
500 |
|
- |
| 10.1(HV (water immersion)) |
- |
1000 |
|
- |
| 10.1(HV (water immersion)) |
- |
1000 |
|
- |
| 10.2(HV (room temperature)) |
- |
1000 |
|
- |
| 9(Overall dimensions) |
- |
500 |
|
- |
| 8.3(Minimum thickness of Sheath) |
- |
500 |
|
- |
| 8.3(Avarage thickness of Sheath) |
- |
500 |
|
- |
| 5.3(Minimum thickness of insulation) |
- |
500 |
|
- |
| 5.3(Avarage thickness of insulation) |
- |
500 |
|
- |
| Table 4(Copper purity test) |
- |
2000 |
|
- |
|
28 Nov, 2028 |
- - |
| 562 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 14255 (1995) |
Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Phase/Street Lighting conductor) |
- |
500 |
|
- |
| 4.2(Messenger (Neutral Conductor or Otherwise)) |
- |
500 |
|
- |
| 5.1(Insulation) |
- |
500 |
|
- |
| 6.1(Flexibility class) |
- |
500 |
|
- |
| 6.2(Compactness) |
- |
500 |
|
- |
| 6.2(No of strands) |
- |
500 |
|
- |
| 6.2(Surface) |
- |
500 |
|
- |
| 6.3(Protective barrier) |
- |
100 |
|
- |
| 6.4(size of street lighting conductor) |
- |
500 |
|
- |
| 6.5(Size of messenger conductor ) |
- |
500 |
|
- |
| 6.6(Joints in messenger conductor ) |
- |
500 |
|
- |
| 6.6(Direction of outer layer) |
- |
500 |
|
- |
| 7.1(Insulation) |
- |
500 |
|
- |
| 7.2( Thickness of insulation) |
- |
1000 |
|
- |
| 7.3(Tolerance on thickness of insulation ) |
- |
1000 |
|
- |
| 7.4(Aplication of the insulation ) |
- |
1000 |
|
- |
| 7.5(Colour of the insulation ) |
- |
500 |
|
- |
| 8.1(Core identification) |
- |
500 |
|
- |
| 8.2(Core identification) |
- |
500 |
|
- |
| 8.3(Identification by other means) |
- |
500 |
|
- |
| 9.1(Assembly (Laying up)) |
- |
500 |
|
- |
| 9.2(Assembly (Laying up)) |
- |
1000 |
|
- |
| 9.3(Direction of lay) |
- |
500 |
|
- |
| 10.1 a) i)(Tests on phase/street light conductor: tensile test - Test method IS10810:Part 2) |
- |
1000 |
|
- |
| 10.1 a) ii)(Wrapping test - 10810: Part 3) |
- |
1000 |
|
- |
| 10.1 a) iii)(Resistance test - IS10810: Part 5) |
- |
1000 |
|
- |
| 10.1 b) i)(Test on messenger conductor: Breaking load - IS 10810: Part 2) |
- |
1000 |
|
- |
| 10.1 b) ii)(Test on messenger conductor: Elongation test - Cl 11.3) |
- |
1000 |
|
- |
| 10.1 b) iii)(Test on messenger conductor: Resistance test - IS 10810: Part 5) |
- |
1000 |
|
- |
| 10.1 c) i)(Physical tests for XLPE Insulation:
Tensile strength - IS 10810: Part 7) |
- |
1000 |
|
- |
| 10.1 c) i)(Physical tests for XLPE Insulation:
elongation at break - IS 10810: part 7) |
- |
1000 |
|
- |
| 10.1 c) ii)(Ageing in air oven : Tensile strength variation - IS 10810:Part 11) |
- |
1000 |
|
- |
| 10.1 c) ii)(Ageing in air oven : Elongation variation- IS 10810: Part 11) |
- |
1000 |
|
- |
| 10.1 c) iii)(Hot set test: Elongation under load - IS 10810: Part 30) |
- |
1000 |
|
- |
| 10.1 c) iii)(Hot set test: Permanent elongation (set) after cooling - IS 10810: Part 30) |
- |
1000 |
|
- |
| 10.1 c) iv)(Shrinkage test : Shrinkage - 10810:Part 12) |
- |
1000 |
|
- |
| 10.1 c) iv)(Shrinkage test : Crack Observed - 10810:Part 12) |
- |
1000 |
|
- |
| 10.1 c) v)(Water ahsorption (Gravimetric) - IS 10810: Part 33 ) |
- |
1000 |
|
- |
| 10.1 d) i)(Physical test for PE insulation:
Tensile strength - IS 10810: Part 7 ) |
- |
1000 |
|
- |
| 10.1 d) i)(Physical test for PE insulation: elongation at break - IS 10810: Part 7) |
- |
1000 |
|
- |
| 10.1 d) ii)(Melt flow index- IS 10810: Part 23) |
- |
1000 |
|
- |
| 10.1 d) iv)(Vicat softening point -IS 10810: Part 22) |
- |
1000 |
|
- |
| 10.1 d) v)(Environmental stress cracking -IS 10810:Part29) |
- |
1000 |
|
- |
| 10.1 f)(Insulation resistance (Volume resistivity) test a) volume resistivity at 27°C - IS 10810: Part 43) |
- |
1000 |
|
- |
| 10.1 f)(Insulation resistance (Volume resistivity) test b) volume resistivity at 70°C - IS 10810: Part 43) |
- |
1000 |
|
- |
| 10.1 g)(High voltage test - IS10810:Part 45) |
- |
1000 |
|
- |
| 11.4(Bending Test on the Completed Cable ( Optional) ) |
- |
1000 |
|
- |
|
28 Nov, 2028 |
- - |
| 563 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 398 : Part 4 (1994) |
Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
Al alloy stranded conductor |
5400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Freedom from Defects) |
- |
600 |
|
- |
| 7.1 Table-1(Dimensional measurement of wires) |
- |
600 |
|
- |
| 7.2.2 Table-2, Table-4(Calculated resistance of Stranded Conductor) |
- |
600 |
|
- |
| 9.2 Table 3(Lay Ratio of stranded conductors) |
- |
600 |
|
- |
| 9.3(Direction of Lay) |
- |
600 |
|
- |
| 12.2 Table 1(Breaking Load Test- Before Stranding) |
- |
1000 |
|
- |
| 12.2 Table 1(Breaking Load Test- After Stranding) |
- |
1000 |
|
- |
| 12.3 Table 1(Elongation Test- Before Stranding) |
- |
1000 |
|
- |
| 12.3 Table 1(Elongation Test- After Stranding) |
- |
1000 |
|
- |
| 12.4 Table 1(Resistance of Aluminium wire) |
- |
1000 |
|
- |
| 9.2(Lay Ratio 24 wire layer) |
- |
600 |
|
- |
| 9.2(Lay Ratio 18 wire layer) |
- |
600 |
|
- |
| 9.2(Lay Ratio 12 wire layer) |
- |
600 |
|
- |
| 9.2(Lay Ratio 3/6 wire layer) |
- |
600 |
|
- |
|
28 Nov, 2028 |
- - |
| 564 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 9537 : Part 3 (1983) |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
- |
4950 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Marking) |
- |
200 |
|
- |
| 6.2(Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
200 |
|
- |
| 6.3(Standard Mark on Conduit) |
- |
100 |
|
- |
| 7.1.1(Maximum and minimum outside diameter of socket) |
- |
500 |
|
- |
| 7.2(Minimum inside diameter of conduit) |
- |
500 |
|
- |
| 7.1.1 Table-2(Length of Socket end) |
- |
500 |
|
- |
| 7.4(Unifomity of The wall Thickness) |
- |
500 |
|
- |
| 8.1(Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
| 9.2(Bending Test i) At Room Temp ii) At Low Temp (-5 ±2°C)) |
- |
500 |
|
- |
| 9.3(Compression Test as per caluse 9.3 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
| 9.4(Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
| 9.5(Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
| 10(Resistance to Heat -Ball presure test) |
- |
500 |
|
- |
| 11(Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
| 12(Electrical Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
| 12(Electrical Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
|
28 Nov, 2028 |
- - |
| 565 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 15652 (2006) |
Insulating mats for electrical purposes - Specification |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9(Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
100 |
|
- |
| 9(Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
100 |
|
- |
| 9(Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
100 |
|
- |
| 9(Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
100 |
|
- |
| 9(Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
100 |
|
- |
| 9(Marking (As per Cl.9.2 of IS 15652 : 2006)) |
- |
100 |
|
- |
| 10.a)(Packing) |
- |
300 |
|
- |
| 10.b)(Packing) |
- |
0 |
|
- |
| 10.c)(Packing) |
- |
0 |
|
- |
| 4(Classification and Designation (As per Cl.4.1 and Table-1 of IS 15652 : 2006)) |
- |
100 |
|
- |
| 4(Classification and Designation (As per Cl.4.2 of IS 15652 : 2006)) |
- |
100 |
|
- |
| 5(Composition (As per Cl. 5.1 of IS 15652 : 2006)) |
- |
100 |
|
- |
| 5(Composition (As per Cl. 5.2 of IS 15652 : 2006)) |
- |
100 |
|
- |
| 6(Shape Requirements and Dimension (As per Cl.6.1 & 6.2 of IS 15652 : 2006)) |
- |
100 |
|
- |
| 6(Shape Requirements and Dimension (As per Cl.6.1 & 6.2 of IS 15652 : 2006)) |
- |
500 |
|
- |
| 6(Thickness [mm] (As per Cl. 6.3 and Table-2 of IS 15652 : 2006)) |
- |
1000 |
|
- |
| 6(Thickness [mm] (As per Cl. 6.3 and Table-2 of IS 15652 : 2006)) |
- |
0 |
|
- |
| 6(Thickness [mm] (As per Cl. 6.3 and Table-2 of IS 15652 : 2006)) |
- |
0 |
|
- |
| 6(Colour (As per Cl. 6.4 of IS 15652 : 2006)) |
- |
100 |
|
- |
| 7(Workmanship & Finish (As per Cl. 7.1 of IS 15652 : 2006)) |
- |
100 |
|
- |
| 8(Physical properties (As per Cl.8.1 and Table - 3 of IS 15652 : 2006)) |
- |
500 |
|
- |
| 8(Physical properties (As per Cl.8.1 and Table - 3 of IS 15652 : 2006)) |
- |
500 |
|
- |
| 8(Physical properties (As per Cl.8.3 of IS 15652 : 2006)) |
- |
500 |
|
- |
| 8(Physical properties (As per Cl.8.3 of IS 15652 : 2006)) |
- |
500 |
|
- |
| 8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
500 |
|
- |
| 8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
500 |
|
- |
| 8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
500 |
|
- |
| 8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
500 |
|
- |
| 8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
500 |
|
- |
| 8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
500 |
|
- |
| 8(Di-electric Properties (As per Cl.8.2.1 and C-3.1 of IS 15652 : 2006)) |
- |
500 |
|
- |
| 8(Di-electric Properties (As per Cl.8.2.2 and C-3.2 of IS 15652 : 2006)) |
- |
500 |
|
- |
| 8(Di-electric Properties (As per Cl.8.2.3 and C-3.3 of IS 15652 : 2006)) |
- |
500 |
|
- |
| 8(Di-electric Properties (Cl.8.2), A.C. Proof Voltage (Cl.8.2.4), C-3.4 and Table-5 of IS 15652 : 2006)) |
- |
500 |
|
- |
| 8(Thermal Properties (Cl..8.4)) |
- |
500 |
|
- |
| 8(Thermal Properties (Cl..8.4)) |
- |
500 |
|
- |
| 8(A.C. Proof Voltage (Cl.8.2.4), C-3.4 and Table-5 of IS 15652 : 2006)) |
- |
500 |
|
- |
| 8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
500 |
|
- |
| 8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
500 |
|
- |
| 8(Extreme Low Temperature (Cl.8.6)) |
- |
500 |
|
- |
| 8(A.C. Proof Voltage (Cl.8.2.4), C-3.4 and Table-5 of IS 15652 : 2006)) |
- |
500 |
|
- |
|
28 Nov, 2028 |
- - |
| 566 |
National Test House (NWR) - NTH, Jaipur
| 8122904
| IS 14490 (2024) |
Plain Copier Paper â Specification (Second Revision) |
- |
14000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.1(plain copier paper) |
- |
500 |
|
- |
| 5.3(Grammage (Substance)) |
- |
1000 |
|
- |
| 5.4(Thickness) |
- |
1000 |
|
- |
| 5.5(Size) |
- |
500 |
|
- |
| 5.7(Conditioning specified) |
- |
500 |
|
- |
| 5.6, Table 1, i(ISO brightness, percent, Min) |
- |
2000 |
|
- |
| 5.6, Table 1, ii(Opacity, percent, Min) |
- |
2000 |
|
- |
| 5.6, Table 1, iii(One minute cobb test, both sides, g/m2 , Max) |
- |
2000 |
|
- |
| 5.6, Table 1, iv(Surface strength, Dennison (Wax Pick)) |
- |
2000 |
|
- |
| 5.6, Table 1, v(Smoothness for both sides (Bendsten), ml/min, Max) |
- |
2000 |
|
- |
| 5.6, Table 1, vi(Ash content (at 900 °C), percent by mass, Max) |
- |
1000 |
|
- |
| 5.6, Table 1, vii(Taber stiffness, Min:
Machine direction, Cross direction) |
- |
2000 |
|
- |
| 5.6, Table 1, viii(Tear Index, mN.m2 /g, Min:
Machine direction, Cross direction) |
- |
2000 |
|
- |
| 5.6, Table 1, ix(Tensile index, N.m/g, Min:
Machine direction, Cross direction) |
- |
2000 |
|
- |
| 6(PACKING AND MARKING) |
- |
500 |
|
- |
| 5.1.2(k,) |
- |
500 |
|
- |
| 5.2(Moisture) |
- |
500 |
|
- |
|
31 Dec, 2026 |
- - |
| 567 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
22000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(CONDUCTOR: MATERIALS) |
- |
500 |
|
- |
| 4(INSULATION : MATERIALS) |
- |
500 |
|
- |
| 5.1(FILLER AND INNER SHEATH) |
- |
500 |
|
- |
| 6(ARMOURING) |
- |
500 |
|
- |
| 7(OUTER SHEATH) |
- |
500 |
|
- |
| 8.1(CONDUCTOR: CONSTRUCTION) |
- |
500 |
|
- |
| 8.2(PROTECTIVE BARRIER) |
- |
500 |
|
- |
| 8.3(SIZE OF NEUTRAL CONDUCTOR) |
- |
500 |
|
- |
| 9.1(Insulation Applied by extrusicn) |
- |
500 |
|
- |
| 9.2(Thickness of Insulation - Average) |
- |
500 |
|
- |
| 9.3(Thickness of Insulation - Minimum) |
- |
500 |
|
- |
| 9.4(Application of Insulation) |
- |
500 |
|
- |
| 10.1(Core Identification) |
- |
500 |
|
- |
| 10.2(Core Identification- Neutral) |
- |
500 |
|
- |
| 10.3(Core Identification by number ) |
- |
500 |
|
- |
| 10.4(Core Identification by number - Neutral ) |
- |
500 |
|
- |
| 11(LAVING UP OF CORES) |
- |
500 |
|
- |
| 12.1 & 12.2(Inner sheath : Application) |
- |
500 |
|
- |
| 12.3(Thickness of Inner Sheath) |
- |
500 |
|
- |
| 13.1(Armouring: Application) |
- |
500 |
|
- |
| 13.1.2(Armouring: Coverage ) |
- |
500 |
|
- |
| 13.1.3(Armouring: Direction of Lay ) |
- |
500 |
|
- |
| 13.2(Type of armour ) |
- |
500 |
|
- |
| 13.3(Armouring : Dimensions -Wire Diameter) |
- |
500 |
|
- |
| 13.3(Armouring : Dimensions -Formed wire ) |
- |
500 |
|
- |
| 13.5(Armouring : Resistance Test) |
- |
1000 |
|
- |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
1000 |
|
- |
| 13.6 b)(ARMOURING: Elongation ) |
- |
1000 |
|
- |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
1000 |
|
- |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
1000 |
|
- |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
1000 |
|
- |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
1000 |
|
- |
| 13.6 g)(ARMOURING: Resistivity) |
- |
1000 |
|
- |
| 14.1(Outer Sheath : Application) |
- |
1000 |
|
- |
| 14.2(Colour of outer sheath) |
- |
1000 |
|
- |
| 14.3(Thickness of outer sheath - AVERAGE) |
- |
1000 |
|
- |
| 15.1 a) i)(Annealing Test ( For copper wire ) ) |
- |
1000 |
|
- |
| 15.1 a) ii)(Tensile test (for aluminium) - Before stranding ) |
- |
1000 |
|
- |
| 15.1 a) ii)(Tensile test (for aluminium) - After stranding ) |
- |
1000 |
|
- |
| 15.1 a) iii)(Wrapping test (for aluminium)) |
- |
500 |
|
- |
| 15.1 a) iv)(Resistance test - Main conductor) |
- |
1000 |
|
- |
| 15.1 a) iv)(Resistance test - Neutral conductor) |
- |
1000 |
|
- |
| 15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
1000 |
|
- |
| 15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
1000 |
|
- |
| 15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
1000 |
|
- |
| 15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
1000 |
|
- |
| 15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
1000 |
|
- |
| 15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
1000 |
|
- |
| 15.1 d) iv) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
1000 |
|
- |
| 15.1 d) v) (Insulation: Waterabsorption(gravimetric)) |
- |
1000 |
|
- |
| 15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
1000 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
1000 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
1000 |
|
- |
| 15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
1000 |
|
- |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
1000 |
|
- |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
1000 |
|
- |
| 15.1 e) v) (Sheath : Hot deformation) |
- |
1000 |
|
- |
| 15.1 e) vi) (Sheath : Heat shock test) |
- |
1000 |
|
- |
| 15.1 e) vii) (Sheath : Thermalstability) |
- |
1000 |
|
- |
| 15.1 f)(INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
1000 |
|
- |
| 16.2(HIGH VOLTAGE TEST ) |
- |
1000 |
|
- |
| 16.3(FLAMMABILITY TEST : Period of Burning ) |
- |
500 |
|
- |
| 16.3(FLAMMABILITY TEST : Unaffected length ) |
- |
500 |
|
- |
| 16.9(Oxygen Index Test) |
- |
5000 |
|
- |
| 16.14(Temperature Index) |
- |
5000 |
|
- |
| 16.1(Flame Retardance Test on Single Cables) |
- |
5000 |
|
- |
| 16.11(Flame Retardance Test on Bunched Cables) |
- |
5000 |
|
- |
| 16.13(Test for Halogen Acid Gas Evolution) |
- |
5000 |
|
- |
| 17.1(Manufacturer'. identification) |
- |
500 |
|
- |
| 17.2(cable Indentification ) |
- |
500 |
|
- |
| 17.3(cable Code ) |
- |
500 |
|
- |
| 15.4 (a)(Cold bend) |
- |
500 |
|
- |
| 15.4 (b)(Cold impact) |
- |
500 |
|
- |
| Cl No. 16.15(Smoke density test) |
- |
5000 |
|
- |
| 15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
1500 |
|
- |
| Table 1(Ageing in air oven - Elongation on Insulation) |
- |
1500 |
|
- |
|
28 Nov, 2028 |
- - |
| 568 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 12776 (2002) |
Galvanized strand for earthing - Specification (First Revision) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2(Freedom From Defects (IS 12776)) |
- |
250 |
|
- |
| 5.3(Joints in wires (IS 12776)) |
- |
250 |
|
- |
| 6- Annex-A, Sl-2(Size of the wire (IS 12776)) |
- |
250 |
|
- |
| 6- Annex-A, Sl-8(Lay (IS 12776)) |
- |
250 |
|
- |
| 8.1-Annex-A,Sl-9(Breaking Force of Strand (IS 12776)) |
- |
1500 |
|
- |
| 8.2-Annex-A,Sl-6(Elongation of wire, IS 10810(Part-37)) |
- |
1500 |
|
- |
| 8.3-Annex-A,Sl-12(Resistance at 200 C (IS 12776)) |
- |
1500 |
|
- |
| 8.4(Wrapping Test (IS 12776)) |
- |
500 |
|
- |
| 8.5-Annex-A-Sl-7a(Amount of zinc Coating (IS 6745)) |
- |
1000 |
|
- |
| 8.5-Annex-A-Sl-7b(Uniformity of Coating (IS 2633)) |
- |
1000 |
|
- |
| 8.5-Annex-A-Sl-4(Torsion Test IS 10810(Part-37)) |
- |
500 |
|
- |
| 8.2-Annex-A,Sl-3(Tensile Strength of wire IS 10810(Part-37)) |
- |
1500 |
|
- |
|
28 Nov, 2028 |
- - |
| 569 |
NATIONAL TEST HOUSE-SR (NTH), Chennai
| 6122704
| IS 2830 (2012) |
Carbon steel cast billet ingots, billets, blooms and slabs for re-rolling into steel for general structural purposes - Specification (Third Revision) |
- |
4000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Carbon %) |
- |
800 |
|
nil |
| 6.1(Manganese %) |
- |
800 |
|
nil |
| 6.1(Phosphorus %) |
- |
800 |
|
nil |
| 6.1(Sulphur %) |
- |
800 |
|
nil |
| 6.1( Copper %) |
- |
800 |
|
nil |
| 6.1(Silicon %) |
- |
800 |
|
- |
|
28 Nov, 2028 |
- - |
| 570 |
National Test House (NWR) - NTH, Jaipur
| 8122904
| IS 8042 (2015) |
White portland cement - Specification (Third Revision) |
- |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 -Table 2- i(Fineness 4031 Part 2) |
- |
1000 |
|
-- |
| 6 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
1000 |
|
-- |
| 6 -Table 2- ii- a(Expansion after aeration - 4031 Part 3) |
- |
1000 |
|
-- |
| 6 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
1000 |
|
-- |
| 6-Table 2- ii- b(Expansion after aeration- 4031 Part 3) |
- |
1000 |
|
-- |
| 6 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
500 |
|
-- |
| 6 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
500 |
|
-- |
| 6 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
1000 |
|
-- |
| 6 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
1000 |
|
-- |
| 6 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
1000 |
|
-- |
| 6 -Table 2- vi(Degree of whiteness-Annex B) |
- |
3000 |
|
-- |
| 5 - Table - 1 i(Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
500 |
|
- |
| 5 - Table - 1 ii(Iron oxide - Cl 4.5 of IS 4032:1985) |
- |
500 |
|
- |
| 5 - Table - 1 iii(Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
500 |
|
- |
| 5 - Table - 1 iv(Magnesia - Cl 4.8 of IS 4032:1985) |
- |
1000 |
|
- |
| 5 - Table - 1 v(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
500 |
|
- |
| 5 - Table - 1 vi(Loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
500 |
|
- |
| 5 - Table - 1 vii(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
500 |
|
- |
|
31 Dec, 2026 |
- - |