601 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 5522 (2014) |
Stainless steel sheets and strips for utensils - Specification (Third Revision) |
- |
-
|
6000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl . 6 .0(Freedom from defect) |
- |
100 |
|
- |
Cl. 7.1 & 7.2 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
Cl. 7.1 & 7.2 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
Cl. 7.1 & 7.2 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
2002 |
|
- |
Cl. 7.1 & 7.2 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
Cl. 7.1 & 7.2 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
Cl. 7.1 & 7.2 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
Cl. 7.1 & 7.2 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
Cl. 7.1 & 7.2 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
8.2, Table 3(Tensile Test-1608:Part 1) |
- |
2000 |
|
- |
8.2, Table 3(Proof Stress, N/mm2) |
- |
1500 |
|
- |
8.2, Table 3(Tensile Strength, N/mm2) |
- |
1000 |
|
- |
8.2, Table 3(Elongation, %) |
- |
800 |
|
- |
8.3(Hardness , max-IS 1500 or IS 1501 (Part 1) or IS 1586) |
- |
800 |
|
- |
8.4(Bend Test) |
- |
500 |
|
- |
8.5(Erichsen Cupping Test) |
- |
700 |
|
- |
10.1(Thickness, mm) |
- |
200 |
|
- |
10.2(width, mm) |
- |
200 |
|
- |
10.3(Length, mm) |
- |
200 |
|
- |
10.4(Flatness,mm) |
- |
200 |
|
- |
10.5(Camber, mm) |
- |
200 |
|
- |
11(Surface Finish) |
- |
100 |
|
- |
|
Complete
|
|
26 Sep, 2027 |
- - |
602 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 740 (1977) |
Specification for wrought aluminium and aluminium alloy rivet stock for general engineering purposes (Second Revision) |
- |
-
|
13000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1,
Table 1of IS:740 (Designation 65032)(Aluminium) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Aluminium) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Aluminium) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Aluminium) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 24345)(Aluminium) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 19000)(Aluminium) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 65032)(Either Cr or Mn shall present) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 65032)(Titanium and or other grain refining elements) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Cr+Mn) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Titanium and or other grain refining elements) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Cr+Mn) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Titanium and or other grain refining elements) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Cr+Mn) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Titanium and or other grain refining elements) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 24345)(Titanium and or other grain refining elements) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 19000)(Cu+Mg+Si+Fe+Mn+Zn) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 65032)(Chromium) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 65032)(Copper) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 65032)(Iron) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 65032)(Magnesium) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 65032)(Manganese) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 65032)(Silicon) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 65032)(Zinc) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Chromium) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Chromium) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Chromium) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 24345)(Chromium) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Copper) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Copper) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Copper) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 24345)(Copper) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 19000)(Copper) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Iron) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Iron) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Iron) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 24345)(Iron) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 19000)(Iron) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Magnesium) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Magnesium) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Magnesium) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 24345)(Magnesium) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 19000)(Magnesium) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Manganese) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Manganese) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Manganese) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 24345)(Manganese) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 19000)(Manganese) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Silicon) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Silicon) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Silicon) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 24345)(Silicon) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 19000)(Silicon) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 64430)(Zinc) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 55000)(Zinc) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 53000)(Zinc) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 24345)(Zinc) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation 19000)(Zinc) |
- |
600 |
|
- |
4.1,
Table 1of IS:740 (Designation & Condition 65032, 'W')(Tensile Strength of Size upto and including 25 mm) |
- |
2000 |
|
- |
4.1,
Table 1of IS:740 (Designation & Condition 64430, 'W')(Tensile Strength of Size upto and including 25 mm) |
- |
2000 |
|
- |
4.1,
Table 1of IS:740 (Designation & Condition 55000, 'OD')(Tensile Strength of Size upto and including 25 mm) |
- |
2000 |
|
- |
4.1,
Table 1of IS:740 (Designation & Condition 55000, 'O or M')(Tensile Strength of Size upto and including 25 mm) |
- |
2000 |
|
- |
4.1,
Table 1of IS:740 (Designation & Condition 53000, 'OD')(Tensile Strength of Size upto and including 25 mm) |
- |
2000 |
|
- |
4.1,
Table 1of IS:740 (Designation & Condition 53000, 'O or M')(Tensile Strength of Size upto and including 25 mm) |
- |
2000 |
|
- |
4.1,
Table 1of IS:740 (Designation & Condition 24345, 'W')(Tensile Strength of Size upto and including 12 mm) |
- |
2000 |
|
- |
4.1,
Table 1of IS:740 (Designation & Condition 19000, '112')(Tensile Strength of Size upto and including 12 mm) |
- |
2000 |
|
- |
6(Freedom From Defects) |
- |
500 |
|
- |
7(Dmension And Tolerances) |
- |
500 |
|
- |
9.2(Head Forming Test) |
- |
1500 |
|
- |
11(Marking) |
- |
200 |
|
- |
|
Complete
|
|
26 Sep, 2027 |
- - |
603 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 739 (1992) |
Wrought aluminium and aluminium alloys - Wire for general engineering purposes - Specification (Third Revision) |
- |
-
|
11000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Freedom from defects) |
- |
300 |
|
- |
7.0(Dimension and Tolerances) |
- |
500 |
|
- |
8.1 Table-1(Al) |
- |
800 |
|
- |
8.1 Table-1(Cu) |
- |
800 |
|
- |
8.1 Table-1(Mg) |
- |
800 |
|
- |
8.1 Table-1(Si) |
- |
800 |
|
- |
8.1 Table-1(Fe) |
- |
800 |
|
- |
8.1 Table-1(Mn) |
- |
800 |
|
- |
8.1 Table-1(Zn) |
- |
800 |
|
- |
8.1 Table-1(Ti) |
- |
800 |
|
- |
8.1 Table-1(Cr) |
- |
800 |
|
- |
9.1(Tensile Strength) |
- |
2500 |
|
- |
9.3(Wrapping Test) |
- |
1500 |
|
- |
10(Selection of Test Samples) |
- |
500 |
|
- |
|
Complete
|
|
26 Sep, 2027 |
- - |
604 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 737 (2008) |
Wrought aluminium and aluminium alloy sheet and strip for general engineering purposes - Specification (Fourth Revision) |
- |
-
|
9000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.0(Freedom from defects) |
- |
200 |
|
- |
6 Table-1(Al) |
- |
500 |
|
- |
6 Table-1(Cr) |
- |
500 |
|
- |
6 Table-1(Cu) |
- |
500 |
|
- |
6 Table-1(Mg) |
- |
500 |
|
- |
6 Table-1(Mn) |
- |
500 |
|
- |
6 Table-1(Si) |
- |
500 |
|
- |
6 Table-1(Fe) |
- |
500 |
|
- |
6 Table-1(Zn) |
- |
500 |
|
- |
6 Table-1(Ti) |
- |
500 |
|
- |
6 Table-1(Cu+Si+Fe) |
- |
500 |
|
- |
6 Table-1(Cu+Si+Fe+Mn+Zn) |
- |
500 |
|
- |
6 Table-1(Cu+Mg+Si+Fe+Mn+Zn) |
- |
500 |
|
- |
6 Table-1(Zr) |
- |
500 |
|
- |
6 Table-1(Cr+Mn) |
- |
500 |
|
- |
7 Table-2(Tensile Strength) |
- |
1000 |
|
- |
7 Table-2(Elongation) |
- |
1000 |
|
- |
7 Table-2(0.2 % Proof Stress) |
- |
1300 |
|
- |
7 Table-2(Bend Test) |
- |
900 |
|
- |
9(Dimension - IS 2676) |
- |
500 |
|
- |
12(Marking) |
- |
300 |
|
- |
|
Complete
|
|
26 Sep, 2027 |
- - |
605 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 733 (1983) |
Specification for wrought aluminium and aluminium alloy bars, rods and sections (For General Engineering Purposes) (Third Revision) |
- |
-
|
8000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 4(Freedom from Defects) |
- |
200 |
|
- |
Cl. 5.1, Table 2(Tensile Strength- IS 1816) |
- |
1000 |
|
- |
Cl. 5.1, Table 2(Elongation on 50 mm or 5.65√So Gauge Length) |
- |
1000 |
|
- |
Cl. 5.1, Table 2(0.2 Percent proof stress- IS 1816) |
- |
1300 |
|
- |
Cl. 0.4, 5.1, Table 1(Aluminium- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
Cl. 0.4, 5.1, Table 1(Chromium- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
Cl. 0.4, 5.1, Table 1(Copper- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
Cl. 0.4, 5.1, Table 1(Magnesium- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
Cl. 0.4, 5.1, Table 1(Silicon- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
Cl. 0.4, 5.1, Table 1(Iron- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
Cl. 0.4, 5.1, Table 1(Zinc- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
Cl. 0.4, 5.1, Table 1(Titanium and / or other grain refining elements - IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
Cl. 0.4, 5.1, Table 1(Ti+ V- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
Cl. 0.4, 5.1, Table 1(Total Impurities- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
Cl. 0.4, 5.1, Table 1(Cr+ Mn- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
7(Dimension - IS 3965) |
- |
400 |
|
- |
11(Marking) |
- |
300 |
|
- |
Cl. 4(Freedom from Defects) |
- |
- |
|
- |
Cl. 5.1, Table 2(Tensile Strength- IS 1816) |
- |
- |
|
- |
Cl. 5.1, Table 2(Elongation on 50 mm or 5.65√So Gauge Length) |
- |
- |
|
- |
Cl. 5.1, Table 2(0.2 Percent proof stress- IS 1816) |
- |
- |
|
- |
Cl. 0.4, 5.1, Table 1(Aluminium- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
Cl. 0.4, 5.1, Table 1(Chromium- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
Cl. 0.4, 5.1, Table 1(Copper- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
Cl. 0.4, 5.1, Table 1(Magnesium- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
Cl. 0.4, 5.1, Table 1(Silicon- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
Cl. 0.4, 5.1, Table 1(Iron- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
Cl. 0.4, 5.1, Table 1(Zinc- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
Cl. 0.4, 5.1, Table 1(Titanium and / or other grain refining elements - IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
Cl. 0.4, 5.1, Table 1(Ti+ V- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
Cl. 0.4, 5.1, Table 1(Total Impurities- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
Cl. 0.4, 5.1, Table 1(Cr+ Mn- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
7(Dimension - IS 3965) |
- |
- |
|
- |
11(Marking) |
- |
- |
|
- |
|
Complete
|
|
26 Sep, 2027 |
- - |
606 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 13983 (1994) |
Stainless Steel Sinks For Domestic Purposes |
- |
-
|
7000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Type) |
- |
200 |
|
- |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Carbon Content) |
- |
300 |
|
- |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Silicon Content) |
- |
300 |
|
- |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Manganese Content) |
- |
300 |
|
- |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Nickel Content) |
- |
300 |
|
- |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Chromium Content) |
- |
300 |
|
- |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Sulphur Content) |
- |
300 |
|
- |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Phouphorous Content) |
- |
300 |
|
- |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Nitrogen Content) |
- |
300 |
|
- |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Carbon Content) |
- |
300 |
|
- |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Silicon Content) |
- |
300 |
|
- |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Manganese Content) |
- |
300 |
|
- |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Nickel Content) |
- |
300 |
|
- |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Chromium Content) |
- |
300 |
|
- |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Sulphur Content) |
- |
300 |
|
- |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Phouphorous Content) |
- |
300 |
|
- |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Nitrogen Content) |
- |
300 |
|
- |
6(Thickness of sheet/strip) |
- |
400 |
|
- |
6(Depth of bowl) |
- |
400 |
|
- |
6(Internal dimensions of the bowl) |
- |
400 |
|
- |
6.4.1(Bowl Locating Limits) |
- |
400 |
|
- |
6(Co-ordinating sizes) |
- |
400 |
|
- |
7.1(Consruction and workmanship) |
- |
400 |
|
- |
7.1.1(Consruction and workmanship) |
- |
400 |
|
- |
7.2(Consruction and workmanship) |
- |
400 |
|
- |
7.2.1(Consruction and workmanship) |
- |
400 |
|
- |
7.3(CONSTRUCTION AND WORKMANSHIP) |
- |
400 |
|
- |
7.4(Waste Outlet) |
- |
400 |
|
- |
7.5(Tap holes) |
- |
400 |
|
- |
7.6(OVERFLOW) |
- |
400 |
|
- |
8(Finish) |
- |
400 |
|
- |
|
Complete
|
|
26 Sep, 2027 |
- - |
607 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 7231 (2021) |
Plastic flushing cisterns for water closets and urinals - Specification (third revision) |
- |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1.1(Construction of Exposed Cistern) |
- |
200 |
|
5% discount for BIS |
5.1.1(Construction of Exposed Cistern) |
- |
200 |
|
5% discount for BIS |
5.1.1(Construction of Exposed Cistern) |
- |
200 |
|
5% discount for BIS |
5.1.2(Construction of Cover) |
- |
200 |
|
5% discount for BIS |
5.1.3(Construction of Flush Pipe) |
- |
200 |
|
5% discount for BIS |
5.1.3.1(Flush pipe connection to cistern) |
- |
200 |
|
5% discount for BIS |
5.1.3.1(Flush pipe connection to cistern) |
- |
200 |
|
5% discount for BIS |
5.1.3.1(Flush pipe connection to cistern) |
- |
200 |
|
5% discount for BIS |
5.1.3.1(Flush pipe connection to cistern) |
- |
200 |
|
5% discount for BIS |
5.1.4(Inlet and Overflow Holes) |
- |
200 |
|
5% discount for BIS |
5.1.5(Float Valve) |
- |
200 |
|
5% discount for BIS |
5.1.6(Operating Mechanism (Push-Knob)) |
- |
200 |
|
5% discount for BIS |
5.1.6(Operating Mechanism (Push-Knob)) |
- |
200 |
|
5% discount for BIS |
5.1.7(Overflow Pipe) |
- |
200 |
|
5% discount for BIS |
5.1.7.2(Overflow Pipe) |
- |
200 |
|
5% discount for BIS |
5.1.7.3(Overflow Pipe) |
- |
200 |
|
5% discount for BIS |
5.2.1(Concealed Cistern) |
- |
200 |
|
5% discount for BIS |
5.2.1(Concealed Cistern- Construction) |
- |
200 |
|
5% discount for BIS |
5.2.2(Flush Pipe) |
- |
200 |
|
5% discount for BIS |
5.2.3(Operating Mechanism) |
- |
200 |
|
5% discount for BIS |
5.2.3(Operating Mechanism) |
- |
200 |
|
5% discount for BIS |
6, 6.1(Finish) |
- |
200 |
|
5% discount for BIS |
6.1(Finish) |
- |
200 |
|
5% discount for BIS |
6.1(Finish) |
- |
800 |
|
5% discount for BIS |
6.2(Finish) |
- |
800 |
|
5% discount for BIS |
7.1(Operational and Performance Requirement- Flushing Arrangement) |
- |
300 |
|
5% discount for BIS |
7.2(Working Water Level) |
- |
300 |
|
5% discount for BIS |
7.3(Freedom from Leakage) |
- |
300 |
|
5% discount for BIS |
7.4(Reduced Water Level) |
- |
300 |
|
5% discount for BIS |
7.5 (a)(Cistern Discharge Capacity 6/3 Litres) |
- |
600 |
|
5% discount for BIS |
7.5 (a)(Cistern Discharge Capacity 6/3 Litres) |
- |
600 |
|
5% discount for BIS |
7.5 (b)(Cistern Discharge Capacity 4.8/2.8 litres) |
- |
600 |
|
5% discount for BIS |
7.5 (b)(Cistern Discharge Capacity 4.8/2.8 litres) |
- |
600 |
|
5% discount for BIS |
7.5 (c)(Cistern Discharge Capacity 4/2 litres) |
- |
600 |
|
5% discount for BIS |
7.5 (c)(Cistern Discharge Capacity 4/2 litres) |
- |
600 |
|
5% discount for BIS |
7.6 (a)(Discharge Rate) |
- |
900 |
|
5% discount for BIS |
7.6 (b)(Discharge Rate) |
- |
900 |
|
5% discount for BIS |
7.6 (c)(Discharge Rate) |
- |
900 |
|
5% discount for BIS |
7.6(Discharge Rate) |
- |
900 |
|
5% discount for BIS |
8.1(Distortion Resistance Test) |
- |
500 |
|
5% discount for BIS |
8.2(Dead Load Test) |
- |
800 |
|
5% discount for BIS |
8.3(Front Thrust Test) |
- |
800 |
|
5% discount for BIS |
8.4(Impact Test) |
- |
900 |
|
5% discount for BIS |
8.4.1(Impact Test) |
- |
900 |
|
5% discount for BIS |
9.3(Endurance Test) |
- |
3000 |
|
5% discount for BIS |
|
Complete
|
|
26 Sep, 2027 |
- - |
608 |
Ace Test Labs & Metrology Pvt. Ltd.
| IS 14203 (2023) |
FIRE RESISTING RECORD PROTECTION CABINETS SPECIFICATION Second Revision of IS 14203 |
- |
-
|
198000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3 and 6 (Table 1)(Nominal Sizes - Height) |
- |
20000 |
|
- |
3 and 6 (Table 1)(Nominal Sizes - Width) |
- |
20000 |
|
- |
3 and 6 (Table 1)(Nominal Sizes - Depth) |
- |
20000 |
|
- |
3 and 6 (Table 1)(Height of Pedestal) |
- |
20000 |
|
- |
7(Designation) |
- |
20000 |
|
- |
8.1(Cabinet Construction) |
- |
20000 |
|
- |
8.2(Locking Mechanism) |
- |
100000 |
|
- |
8.3(Locks) |
- |
20000 |
|
- |
8.4(Handles) |
- |
20000 |
|
- |
9(Internal Fixtures) |
- |
20000 |
|
- |
10.1(Minimum overall thinckness of coating) |
- |
20000 |
|
- |
10.2(Cross Hatch Test) |
- |
20000 |
|
- |
11, Annex-B, 3.1(Fire Endurance Test) |
- |
120000 |
|
- |
11, Annex-B, 3.2(Fire and Impact test) |
- |
100000 |
|
- |
3 and 6 (Table 1)(Nominal Sizes - Height) |
- |
20000 |
|
- |
3 and 6 (Table 1)(Nominal Sizes - Width) |
- |
20000 |
|
- |
3 and 6 (Table 1)(Nominal Sizes - Depth) |
- |
20000 |
|
- |
3 and 6 (Table 1)(Height of Pedestal) |
- |
20000 |
|
- |
7(Designation) |
- |
20000 |
|
- |
8.1(Cabinet Construction) |
- |
20000 |
|
- |
8.2(Locking Mechanism) |
- |
20000 |
|
- |
8.3(Locks) |
- |
20000 |
|
- |
8.4(Handles) |
- |
20000 |
|
- |
9(Internal Fixtures) |
- |
20000 |
|
- |
10.1(Minimum overall thinckness of coating) |
- |
20000 |
|
- |
10.2(Cross Hatch Test) |
- |
20000 |
|
- |
11, Annex-B, 3.1(Fire Endurance Test) |
- |
120000 |
|
- |
11, Annex-B, 3.2(Fire and Impact test) |
- |
100000 |
|
- |
|
Complete
|
|
14 Nov, 2027 |
- - |
609 |
Atmy Analytical Labs Private Limited (Unit-2)
| IS 14203 (2023) |
FIRE RESISTING RECORD PROTECTION CABINETS SPECIFICATION Second Revision of IS 14203 |
- |
-
|
339000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3 and 6 (Table 1)(Nominal Sizes - Height) |
- |
0 |
|
- |
3 and 6 (Table 1)(Nominal Sizes - Width) |
- |
0 |
|
- |
3 and 6 (Table 1)(Nominal Sizes - Depth) |
- |
0 |
|
- |
3 and 6 (Table 1)(Height of Pedestal) |
- |
0 |
|
- |
7(Designation) |
- |
0 |
|
- |
8.1(Cabinet Construction) |
- |
0 |
|
- |
8.2(Locking Mechanism) |
- |
0 |
|
- |
8.3(Locks) |
- |
0 |
|
- |
8.4(Handles) |
- |
0 |
|
- |
9(Internal Fixtures) |
- |
0 |
|
- |
10.1(Minimum overall thinckness of coating) |
- |
0 |
|
- |
10.2(Cross Hatch Test) |
- |
0 |
|
- |
11, Annex-B, 3.1(Fire Endurance Test) |
- |
0 |
|
- |
11, Annex-B, 3.2(Fire and Impact test) |
- |
0 |
|
- |
|
Complete
|
|
08 Feb, 2027 |
- Included w.e.f. 01.04.2025 |
610 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 3975 (1999) |
Low carbon galvanized steel wires, formed wires and tapes for armouring of cables - Specification (Third Revision) |
- |
-
|
5000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Dimensions) |
- |
600 |
|
- |
11(Freedom from defects) |
- |
600 |
|
- |
9.1(Galvanizing Requirements ) |
- |
500 |
|
- |
9.2(Galvanizing Requirements ) |
- |
500 |
|
- |
9.3(Galvanizing Requirements ) |
- |
500 |
|
- |
8.1(Mechanical Properties (as per table 5 of IS 1608)) |
- |
600 |
|
- |
8.2(Mechanical Properties (as per IS 1717)) |
- |
600 |
|
- |
8.3(Mechanical Properties (as per IS 1755)) |
- |
600 |
|
- |
8.4(Mechanical Properties (as per IS 10810(Part- 42))) |
- |
600 |
|
- |
|
Complete
|
|
26 Sep, 2027 |
- - |
611 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 5484 (1997) |
Ec grade aluminium rod produced by continuous casting and rolling - Specification (Second Revision) |
- |
-
|
6000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8-Table-1(Tensile Strength - IS:1608) |
- |
1500 |
|
- |
9(Resistyvity at 20 degree C -IS:398(P-2)) |
- |
1200 |
|
- |
10.1(Diameter - IS:5484) |
- |
700 |
|
- |
11.1(Joint- IS:5484) |
- |
1000 |
|
- |
12.1(Freedom from defects- IS:5484) |
- |
800 |
|
- |
12.2(Finish - IS:5484) |
- |
800 |
|
- |
|
Complete
|
|
26 Sep, 2027 |
- - |
612 |
Atmy Analytical Labs Private Limited (Unit-2)
| IS 14561 (2014) |
Fire resisting (Insulating) filing cabinets - Specification (Second Revision) |
ALL |
-
|
330000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3(Types & Rating) |
- |
0 |
|
- |
3.1(i) The fire resisting filing cabinets shall be of two types:
a) Vertical fire resisting filing cabinet, and
b) Lateral fire resisting filing cabinet.) |
- |
0 |
|
- |
3.2(ii) The standard and lateral fire resisting filing
cabinets shall have one-drawer or two-drawers or three drawers or four-drawers. A typical drawing of the fire resisting filing cabinet is given in Fig. 1.) |
- |
0 |
|
- |
3.3(iii) The fire resisting filing cabinets shall have fire
resisting ratings of 60 min or 120 min or 180 min or
240 min) |
- |
0 |
|
- |
4(Dimensions and Tolerances, mm) |
- |
0 |
|
- |
4.1(Overall Dimensions of Fire Resisting Filing
Cabinets: The internal usable space of the drawers of fire resisting (insulating) filing cabinets shall be as specified in Table 1 or any other size which is mutually agreed to between the purchaser and the supplier.) |
- |
0 |
|
- |
4.1(Internal usuable space of drawer, mm:) |
- |
0 |
|
- |
4.1(i) Height) |
- |
0 |
|
- |
4.1(ii) Width) |
- |
0 |
|
- |
4.1(iii) Depth) |
- |
0 |
|
- |
4.1(iv) Height of the bottom drawer above floor level) |
- |
0 |
|
- |
5(Materials) |
- |
0 |
|
- |
6(Designations: The filing cabinet shall be designated by the commonly used name, type, the fire rating and the number of this Indian Standard.) |
- |
0 |
|
- |
7(Constructions) |
- |
0 |
|
- |
7.1(Outer body and Inner Box: Outer body and inner box shall be fabricated from mild steel or galvanized steel sheets of not less than 0.8 mm and not more than 1.2 mm nominal thickness. The steel shall not have any burrs or dents. If required the outer
body shall be suitably stiffened to avoid bulging) |
- |
0 |
|
- |
7.2(Cabinets Sub-Assembly: The external body and drawer fronts of the fire resisting (insulating) filing cabinet shall be of double wall type with homogeneous insulating material filled in
between. Further the construction of the cabinet shall be such that each drawer slides in an individual inner box. The inner boxes shall have a insulating layer between each other to prevent fire spreading from one drawer to another. The joining of inner box, intermediate piece and outer body shall be such that, it forms a cavity to receive drawer front ) |
- |
0 |
|
- |
7.3(Filing Drawer: The drawer shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall have an arrangement on the sides suitable for the drawer suspension system and an arrangement to stop it when fully pushed in.) |
- |
0 |
|
- |
7.3.1(Drawer Front: The drawer front shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall be firmly secured to the drawer body by welding, screwing or riveting or any combination of these processes. The construction of drawer front shall be such that it snugly fits in the cavity provided for the same ) |
- |
0 |
|
- |
7.4.1(Latch: Each drawer of the cabinet shall be removable but shall be fitted with a latch/positive stop to prevent inadvertent withdrawal and rebound. Such latch shall be lifted/unlocked by the pull of the handle or any other mechanism.) |
- |
0 |
|
- |
7.4.2(The locking mechanism shall be designed in such
a manner so that there is minimum passage for direct
conduction of heat from outside to inside) |
- |
0 |
|
- |
7.5(Drawer Suspension The drawer suspension shall be either of the following types to ensure withdrawal of the full depth of the drawer:
a) Ball bearing / Roller bearing suspension
(Movement),
b) Solid roller suspension, and
c) Telescopic slide suspension (Extension) |
- |
0 |
|
- |
7.6(Handles: Each drawer shall be provided either with a handle made from ferrous/non-ferrous material suitably coated for corrosion resistance, or any polymer and fixed to the front of the drawer or with a built in pulling mechanism) |
- |
0 |
|
- |
7.6.1(The drawer handle shall be strong enough to take
a minimum pull of 50 N for 2 min. There shall be no
sharp corners or edges to avoid injury and damage to clothing) |
- |
0 |
|
- |
7.7.1(Locks: Top drawer shall be provided with single or dual control key lock having not less than 6 levers or pin cylinder lock having not less than 6 pins, with duplicate keys of stainless steel/nonferrous alloy. Alternatively if required by the purchaser a 3 wheel combination lock or electronic combination lock may be provided either in place of key lock or in addition to key lock) |
- |
0 |
|
- |
7.7.2(Each drawer may also be provided with
individual key lock or pin cylinder lock or combination lock subject to agreement between the purchaser and the supplier.) |
- |
0 |
|
- |
7.8(Locking Mechanism ) |
- |
0 |
|
- |
7.8.1(The locking mechanism shall be such that when
the top drawer is pushed-in fully, it actuates locking
mechanism to lock all other drawers imultaneously,
when they are in pushed-in position) |
- |
0 |
|
- |
7.8.1.1(At the time of locking the cabinet, if one of the
drawers is not fully pushed-in, that drawer shall remain unlocked and can be used. As soon as that drawer is pushed-in fully, it shall get locked automatically without further operation of key by the user.) |
- |
0 |
|
- |
7.8.1.2(In addition to the above, isolation mechanism
shall also be provided to permit independent locking/ use of other drawers. Such isolation mechanism provided on drawers shall be manually operated) |
- |
0 |
|
- |
8(Assemblies) |
- |
0 |
|
- |
8.1(The components shall be assembled by bolting,
welding, riveting or by any combination of these
processes) |
- |
0 |
|
- |
8.2(All joints between outer body and inner boxes,
the drawer front and the outer body shall be such that, there is minimum direct conduction of heat from outer body to inner body) |
- |
0 |
|
- |
9.1(Drawer Suspension Test and Latch Test: The drawer loaded with evenly distributed load of 30 kg
(excluding the weight of drawer) in any drawer shall be operated for 5 000 cycles at a rate of 300 cycles/h ±10 percent. One opening and one closing shall constitute one cycle. The test shall be carried out with maximum two breaks by using electrically or mechanically operated test equipment with a counter fitted on it. After 5 000 cycles the suspension slide and latch mechanism shall not show any apparent distortion, cracks, or failures to operate in a normal smooth manner) |
- |
0 |
|
- |
10.1(Finish: All dents, burrs and sharp edges shall be removed from the various components and they shall be thoroughly degreased and cleaned of rust and scale) |
- |
0 |
|
- |
10.2(The inside and outside surfaces of the fire resisting
(Insulating) filing cabinet shall be painted or powder coated. In case of paint, an appropriate primer and undercoating shall be used in accordance to industry practices. The minimum overall thickness of the coatings shall be 50 μ for powder coating and 70 μ for liquid paint. Cross hatch test shall be conducted to confirm the adhesion of coating in accordance with 10.2.1) |
- |
0 |
|
- |
10.2.1(Cross Hatch Test) |
- |
0 |
|
- |
10.2.1(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks) |
- |
0 |
|
- |
10.2.1(b) Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other) |
- |
0 |
|
- |
10.2.1(c) Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing) |
- |
0 |
|
- |
10.2.1(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2mm size,
totally separated from each other) |
- |
0 |
|
- |
10.2.1(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
0 |
|
- |
10.2.1(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
0 |
|
- |
10.2.1(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
0 |
|
- |
11.1(Fire endurance test) |
- |
0 |
|
- |
11.2(Fire and impact test) |
- |
0 |
|
- |
12.1(Marking of Cabinets:A metal plate showing classification of cabinet together with the manufacturer’s name, serial number and the
year of manufacture shall be fixed inside surface of
the top drawer of the cabinet in such a way that it is
visible when it is opened.) |
- |
0 |
|
- |
12.2(Marking on Keys: The keys shall bear an identification number which shall not be the same as the serial number of the cabinet) |
- |
0 |
|
- |
3(Types & Rating) |
- |
0 |
|
- |
3.1(i) The fire resisting filing cabinets shall be of two types:
a) Vertical fire resisting filing cabinet, and
b) Lateral fire resisting filing cabinet.) |
- |
0 |
|
- |
3.2(ii) The standard and lateral fire resisting filing
cabinets shall have one-drawer or two-drawers or three drawers or four-drawers. A typical drawing of the fire resisting filing cabinet is given in Fig. 1.) |
- |
0 |
|
- |
3.3(iii) The fire resisting filing cabinets shall have fire
resisting ratings of 60 min or 120 min or 180 min or
240 min) |
- |
0 |
|
- |
4(Dimensions and Tolerances, mm) |
- |
0 |
|
- |
4.1(Overall Dimensions of Fire Resisting Filing
Cabinets: The internal usable space of the drawers of fire resisting (insulating) filing cabinets shall be as specified in Table 1 or any other size which is mutually agreed to between the purchaser and the supplier.) |
- |
0 |
|
- |
4.1(Internal usuable space of drawer, mm:) |
- |
0 |
|
- |
4.1(i) Height) |
- |
0 |
|
- |
4.1(ii) Width) |
- |
0 |
|
- |
4.1(iii) Depth) |
- |
0 |
|
- |
4.1(iv) Height of the bottom drawer above floor level) |
- |
0 |
|
- |
5(Materials) |
- |
0 |
|
- |
6(Designations: The filing cabinet shall be designated by the commonly used name, type, the fire rating and the number of this Indian Standard.) |
- |
0 |
|
- |
7(Constructions) |
- |
0 |
|
- |
7.1(Outer body and Inner Box: Outer body and inner box shall be fabricated from mild steel or galvanized steel sheets of not less than 0.8 mm and not more than 1.2 mm nominal thickness. The steel shall not have any burrs or dents. If required the outer
body shall be suitably stiffened to avoid bulging) |
- |
0 |
|
- |
7.2(Cabinets Sub-Assembly: The external body and drawer fronts of the fire resisting (insulating) filing cabinet shall be of double wall type with homogeneous insulating material filled in
between. Further the construction of the cabinet shall be such that each drawer slides in an individual inner box. The inner boxes shall have a insulating layer between each other to prevent fire spreading from one drawer to another. The joining of inner box, intermediate piece and outer body shall be such that, it forms a cavity to receive drawer front ) |
- |
0 |
|
- |
7.3(Filing Drawer: The drawer shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall have an arrangement on the sides suitable for the drawer suspension system and an arrangement to stop it when fully pushed in.) |
- |
0 |
|
- |
7.3.1(Drawer Front: The drawer front shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall be firmly secured to the drawer body by welding, screwing or riveting or any combination of these processes. The construction of drawer front shall be such that it snugly fits in the cavity provided for the same ) |
- |
0 |
|
- |
7.4.1(Latch: Each drawer of the cabinet shall be removable but shall be fitted with a latch/positive stop to prevent inadvertent withdrawal and rebound. Such latch shall be lifted/unlocked by the pull of the handle or any other mechanism.) |
- |
0 |
|
- |
7.4.2(The locking mechanism shall be designed in such
a manner so that there is minimum passage for direct
conduction of heat from outside to inside) |
- |
0 |
|
- |
7.5(Drawer Suspension The drawer suspension shall be either of the following types to ensure withdrawal of the full depth of the drawer:
a) Ball bearing / Roller bearing suspension
(Movement),
b) Solid roller suspension, and
c) Telescopic slide suspension (Extension) |
- |
0 |
|
- |
7.6(Handles: Each drawer shall be provided either with a handle made from ferrous/non-ferrous material suitably coated for corrosion resistance, or any polymer and fixed to the front of the drawer or with a built in pulling mechanism) |
- |
0 |
|
- |
7.6.1(The drawer handle shall be strong enough to take
a minimum pull of 50 N for 2 min. There shall be no
sharp corners or edges to avoid injury and damage to clothing) |
- |
0 |
|
- |
7.7.1(Locks: Top drawer shall be provided with single or dual control key lock having not less than 6 levers or pin cylinder lock having not less than 6 pins, with duplicate keys of stainless steel/nonferrous alloy. Alternatively if required by the purchaser a 3 wheel combination lock or electronic combination lock may be provided either in place of key lock or in addition to key lock) |
- |
0 |
|
- |
7.7.2(Each drawer may also be provided with
individual key lock or pin cylinder lock or combination lock subject to agreement between the purchaser and the supplier.) |
- |
0 |
|
- |
7.8(Locking Mechanism ) |
- |
0 |
|
- |
7.8.1(The locking mechanism shall be such that when
the top drawer is pushed-in fully, it actuates locking
mechanism to lock all other drawers imultaneously,
when they are in pushed-in position) |
- |
0 |
|
- |
7.8.1.1(At the time of locking the cabinet, if one of the
drawers is not fully pushed-in, that drawer shall remain unlocked and can be used. As soon as that drawer is pushed-in fully, it shall get locked automatically without further operation of key by the user.) |
- |
0 |
|
- |
7.8.1.2(In addition to the above, isolation mechanism
shall also be provided to permit independent locking/ use of other drawers. Such isolation mechanism provided on drawers shall be manually operated) |
- |
0 |
|
- |
8(Assemblies) |
- |
0 |
|
- |
8.1(The components shall be assembled by bolting,
welding, riveting or by any combination of these
processes) |
- |
0 |
|
- |
8.2(All joints between outer body and inner boxes,
the drawer front and the outer body shall be such that, there is minimum direct conduction of heat from outer body to inner body) |
- |
0 |
|
- |
9.1(Drawer Suspension Test and Latch Test: The drawer loaded with evenly distributed load of 30 kg
(excluding the weight of drawer) in any drawer shall be operated for 5 000 cycles at a rate of 300 cycles/h ±10 percent. One opening and one closing shall constitute one cycle. The test shall be carried out with maximum two breaks by using electrically or mechanically operated test equipment with a counter fitted on it. After 5 000 cycles the suspension slide and latch mechanism shall not show any apparent distortion, cracks, or failures to operate in a normal smooth manner) |
- |
0 |
|
- |
10.1(Finish: All dents, burrs and sharp edges shall be removed from the various components and they shall be thoroughly degreased and cleaned of rust and scale) |
- |
0 |
|
- |
10.2(The inside and outside surfaces of the fire resisting
(Insulating) filing cabinet shall be painted or powder coated. In case of paint, an appropriate primer and undercoating shall be used in accordance to industry practices. The minimum overall thickness of the coatings shall be 50 μ for powder coating and 70 μ for liquid paint. Cross hatch test shall be conducted to confirm the adhesion of coating in accordance with 10.2.1) |
- |
0 |
|
- |
10.2.1(Cross Hatch Test) |
- |
0 |
|
- |
10.2.1(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks) |
- |
0 |
|
- |
10.2.1(b) Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other) |
- |
0 |
|
- |
10.2.1(c) Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing) |
- |
0 |
|
- |
10.2.1(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2mm size,
totally separated from each other) |
- |
0 |
|
- |
10.2.1(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
0 |
|
- |
10.2.1(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
0 |
|
- |
11.1(Fire endurance test) |
- |
0 |
|
- |
11.2(Fire and impact test) |
- |
0 |
|
- |
12.1(Marking of Cabinets:A metal plate showing classification of cabinet together with the manufacturer’s name, serial number and the
year of manufacture shall be fixed inside surface of
the top drawer of the cabinet in such a way that it is
visible when it is opened.) |
- |
0 |
|
- |
12.2(Marking on Keys: The keys shall bear an identification number which shall not be the same as the serial number of the cabinet) |
- |
0 |
|
- |
10.2.1(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
0 |
|
- |
|
Complete
|
|
08 Feb, 2027 |
- Included w.e.f. 01.04.2025 |
613 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 398 : Part 4 (1994) |
Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
- |
-
|
8000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1(Freedom from Defects) |
- |
500 |
|
- |
7.1 Table-1(Dimensional measurement of wires) |
- |
1000 |
|
- |
7.2.2 Table-2, Table-4(Calculated resistance of Stranded Conductor) |
- |
1000 |
|
- |
8.1(Joints in wires-Conductors Containing Seven Wires) |
- |
500 |
|
- |
8.2(Joints in wires-Conductors Containing More Than Seven Wires) |
- |
500 |
|
- |
9.1(Stranding) |
- |
500 |
|
- |
9.2 Table 3(Lay Ratio of stranded conductors) |
- |
500 |
|
- |
9.3(Direction of Lay) |
- |
500 |
|
- |
9.4(Multiple layers of wires) |
- |
500 |
|
- |
12.2 Table 1(Breaking Load Test- Before Stranding) |
- |
500 |
|
- |
12.2 Table 1(Breaking Load Test- After Stranding) |
- |
500 |
|
- |
12.3 Table 1(Elongation Test- Before Stranding) |
- |
500 |
|
- |
12.3 Table 1(Elongation Test- After Stranding) |
- |
500 |
|
- |
12.4 Table 1(Resistance of Aluminium wire) |
- |
500 |
|
- |
9.2(Lay Ratio 24 wire layer) |
- |
500 |
|
- |
9.2(Lay Ratio 18 wire layer) |
- |
500 |
|
- |
9.2(Lay Ratio 12 wire layer) |
- |
500 |
|
- |
9.2(Lay Ratio 3/6 wire layer) |
- |
500 |
|
- |
7.2.1(Sizes) |
- |
500 |
|
- |
|
Complete
|
|
26 Sep, 2027 |
- - |
614 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 398 : Part 3 (1976) |
Specification for aluminium conductors for overhead transmission purposes: Part 3 aluminium conductors, aluminized steel reinforced (Second Revision) |
- |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12.6(Aluminizing Test) |
- |
500 |
|
- |
7.2.2 Table 3(Resistance test-Aluminium wire Calculated Resistance) |
- |
800 |
|
- |
12.5 Table 1(Resistance test-Aluminium wire after stranding) |
- |
800 |
|
- |
12.5 Table 1(Resistance test-Aluminium wire before Stranding) |
- |
800 |
|
- |
12.4.2(Wrapping TestAluminized Steel Wires After Stranding) |
- |
500 |
|
- |
12.4.2(Wrapping Test Aluminized Steel Wires Before Stranding) |
- |
500 |
|
- |
12.4.1(Wrapping Test Aluminium Wires After Stranding) |
- |
500 |
|
- |
12.4.1(Wrapping Test Aluminium Wires Before Stranding) |
- |
500 |
|
- |
12.3.2(Ductility by Elongation Test after stranding) |
- |
500 |
|
- |
12.3.2(Ductility by Elongation Test before stranding) |
- |
500 |
|
- |
12.3.1(Ductility by Torsion Test after stranding) |
- |
500 |
|
- |
12.3.1(Ductility by Torsion Test before stranding) |
- |
500 |
|
- |
12.2 Table 2(Breaking Load of aluminized steel wires After Stranding) |
- |
500 |
|
- |
12.2 Table 1(Breaking Load of Aluminium Wires After Stranding) |
- |
500 |
|
- |
12.2 Table 2(Breaking Load of aluminized steel wires Before Stranding) |
- |
500 |
|
- |
12.2 Table 1(Breaking Load of Aluminium Wires Before Stranding) |
- |
500 |
|
- |
9.5(STRANDING) |
- |
500 |
|
- |
9.2 Table 4(STRANDING : Lay Ratio For Steel Core) |
- |
500 |
|
- |
9.2 Table 4(STRANDING : Lay Ratio For Aluminium Wire) |
- |
500 |
|
- |
8.2(JOINTS IN WIRES : Aluminized Steel Wires) |
- |
500 |
|
- |
8.1(JOINTS IN WIRES : Aluminium Wires) |
- |
500 |
|
- |
7.1.2.2 Table 2(Diameter of Alumized Steel Wires After Stranding) |
- |
500 |
|
- |
7.1.2.1 Table-1(Diameter of Aluminium Wires After Stranding) |
- |
500 |
|
- |
7.1.2.2 Table 2(Diameter of Alumized Steel Wires Before Stranding) |
- |
500 |
|
- |
7.1.2.1 Table-1(Diameter of Aluminium Wires Before Stranding) |
- |
500 |
|
- |
|
Complete
|
|
26 Sep, 2027 |
- - |
615 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 398 : Part 2 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
- |
-
|
8000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires Before Stranding) |
- |
1000 |
|
- |
8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires After Stranding) |
- |
1000 |
|
- |
8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires After Stranding) |
- |
1000 |
|
- |
10 (elec)(Stranding) |
- |
500 |
|
- |
13.3 Table 1 (mech)(Breaking Load of Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
13.3 Table 2 (mech)(Breaking Load of Steel Wires Before Stranding) |
- |
1000 |
|
- |
13.3 Table 1 (mech)(Breaking Load of Aluminium Wires After Stranding) |
- |
1000 |
|
- |
13.3 Table 2 (mech)(Breaking Load of Steel Wires After Stranding) |
- |
1000 |
|
- |
13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
800 |
|
- |
13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
800 |
|
- |
13.4.2 (elec)(Ductility by Elongation Test before stranding) |
- |
800 |
|
- |
13.4.2 (elec)(Ductility by Elongation Test after stranding) |
- |
800 |
|
- |
13.5.1 (mech)(Wrapping Test Aluminium Wires Before Stranding) |
- |
500 |
|
- |
13.5.1 (mech)(Wrapping Test Aluminium Wires After Stranding) |
- |
500 |
|
- |
13.5.2 (mech)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
500 |
|
- |
13.5.2 (mech)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
500 |
|
- |
13.6 (elec)(Resistance test-Aluminium wire before Stranding) |
- |
1200 |
|
- |
13.6 (elec)(Resistance test-Aluminium wire after stranding) |
- |
1200 |
|
- |
13.7.2 (chem)(Mass of Zinc coating) |
- |
800 |
|
- |
13.7.2 (chem)(Uniformity of Zinc coating) |
- |
800 |
|
- |
13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Outermost Layer) |
- |
500 |
|
- |
13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
500 |
|
- |
13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
500 |
|
- |
13.8 Table-4 (mech)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
500 |
|
- |
|
Complete
|
|
26 Sep, 2027 |
- - |
616 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 398 : Part 1 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) |
- |
-
|
8000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12.2, Table-1(Measurement of diameter of individual aluminium wire) |
- |
1000 |
|
- |
12.3, Table-1(Breaking load before stranding) |
- |
800 |
|
- |
12.3, Table-1(Breaking load after stranding) |
- |
800 |
|
- |
12.4(Wrapping test) |
- |
600 |
|
- |
12.5, Table 1(Resistance test) |
- |
1000 |
|
- |
12.6, Table 3(Measurement of lay ratio) |
- |
600 |
|
- |
9.3(Stranding) |
- |
500 |
|
- |
6(Freedom from defects) |
- |
500 |
|
- |
7.2.1(Sizes) |
- |
500 |
|
- |
8, 8.1, 8.2(Joint in wires, except during stranding) |
- |
500 |
|
- |
9.2(Lay ratio) |
- |
700 |
|
- |
9.4(Multiple layer of wires) |
- |
500 |
|
- |
|
Complete
|
|
26 Sep, 2027 |
- - |
617 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 14255 (1995) |
Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification |
1100V |
-
|
11000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(Phase/Street Lighting conductor) |
- |
100 |
|
- |
4.2(Messenger (Neutral Conductor or Otherwise)) |
- |
100 |
|
- |
5.1(Insulation) |
- |
100 |
|
- |
6.1(Flexibility class) |
- |
100 |
|
- |
6.2(Compactness) |
- |
100 |
|
- |
6.2(No of strands) |
- |
100 |
|
- |
6.2(Surface) |
- |
100 |
|
- |
6.3(Protective barrier) |
- |
100 |
|
- |
6.4(size of street lighting conductor) |
- |
100 |
|
- |
6.5(Size of messenger conductor ) |
- |
100 |
|
- |
6.6(Joints in messenger conductor ) |
- |
100 |
|
- |
6.6(Direction of outer layer) |
- |
100 |
|
- |
7.1(Insulation) |
- |
100 |
|
- |
7.2( Thickness of insulation) |
- |
200 |
|
- |
7.3(Tolerance on thickness of insulation ) |
- |
200 |
|
- |
7.4(Aplication of the insulation ) |
- |
100 |
|
- |
7.5(Colour of the insulation ) |
- |
100 |
|
- |
8.1(Core identification) |
- |
100 |
|
- |
8.2(Core identification) |
- |
100 |
|
- |
8.3(Identification by other means) |
- |
100 |
|
- |
9.1(Assembly (Laying up)) |
- |
100 |
|
- |
9.3(Direction of lay) |
- |
200 |
|
- |
10.1 a) i)(Tests on phase/street light conductor: tensile test - Test method IS10810:Part 2) |
- |
500 |
|
- |
10.1 a) ii)(Wrapping test - 10810: Part 3) |
- |
500 |
|
- |
10.1 a) iii)(Resistance test - IS10810: Part 5) |
- |
700 |
|
- |
10.1 b) i)(Test on messenger conductor: Breaking load - IS 10810: Part 2) |
- |
500 |
|
- |
10.1 b) ii)(Test on messenger conductor: Elongation test - Cl 11.3) |
- |
500 |
|
- |
10.1 b) iii)(Test on messenger conductor: Resistance test - IS 10810: Part 5) |
- |
500 |
|
- |
10.1 c) i)(Physical tests for XLPE Insulation:
Tensile strength - IS 10810: Part 7) |
- |
200 |
|
- |
10.1 c) i)(Physical tests for XLPE Insulation:
elongation at break - IS 10810: part 7) |
- |
200 |
|
- |
10.1 c) ii)(Ageing in air oven : Tensile strength variation - IS 10810:Part 11) |
- |
200 |
|
- |
10.1 c) ii)(Ageing in air oven : Elongation variation- IS 10810: Part 11) |
- |
200 |
|
- |
10.1 c) iii)(Hot set test: Elongation under load - IS 10810: Part 30) |
- |
200 |
|
- |
10.1 c) iii)(Hot set test: Permanent elongation (set) after cooling - IS 10810: Part 30) |
- |
200 |
|
- |
10.1 c) iv)(Shrinkage test : Shrinkage - 10810:Part 12) |
- |
200 |
|
- |
10.1 c) iv)(Shrinkage test : Crack Observed - 10810:Part 12) |
- |
200 |
|
- |
10.1 c) v)(Water ahsorption (Gravimetric) - IS 10810: Part 33 ) |
- |
500 |
|
- |
10.1 d) i)(Physical test for PE insulation:
Tensile strength - IS 10810: Part 7 ) |
- |
500 |
|
- |
10.1 d) i)(Physical test for PE insulation: elongation at break - IS 10810: Part 7) |
- |
500 |
|
- |
10.1 d) ii)(Melt flow index- IS 10810: Part 23) |
- |
500 |
|
- |
10.1 d) iv)(Vicat softening point -IS 10810: Part 22) |
- |
500 |
|
- |
10.1 d) v)(Environmental stress cracking -IS 10810:Part29) |
- |
500 |
|
- |
10.1 f)(Insulation resistance (Volume resistivity) test a) volume resistivity at 27°C - IS 10810: Part 43) |
- |
500 |
|
- |
10.1 f)(Insulation resistance (Volume resistivity) test b) volume resistivity at 70°C - IS 10810: Part 43) |
- |
500 |
|
- |
10.1 g)(High voltage test - IS10810:Part 45) |
- |
500 |
|
- |
11.4(Bending Test on the Completed Cable ( Optional) ) |
- |
500 |
|
- |
|
Complete
|
|
26 Sep, 2027 |
- - |
618 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
1100 |
-
|
13000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3(CONDUCTOR: MATERIALS) |
- |
100 |
|
- |
4(INSULATION : MATERIALS) |
- |
100 |
|
- |
5.1(FILLER AND INNER SHEATH) |
- |
100 |
|
- |
5.2(FILLER AND INNER SHEATH) |
- |
100 |
|
- |
6(ARMOURING) |
- |
100 |
|
- |
7(OUTER SHEATH) |
- |
100 |
|
- |
8.1(CONDUCTOR: CONSTRUCTION) |
- |
100 |
|
- |
8.2(PROTECTIVE BARRIER) |
- |
100 |
|
- |
8.3(SIZE OF NEUTRAL CONDUCTOR) |
- |
100 |
|
- |
9.1(Insulation Applied by extrusicn) |
- |
100 |
|
- |
9.2(Thickness of Insulation - Average) |
- |
500 |
|
- |
9.3(Thickness of Insulation - Minimum) |
- |
500 |
|
- |
9.4(Application of Insulation) |
- |
100 |
|
- |
10.1(Core Identification) |
- |
100 |
|
- |
10.2(Core Identification- Neutral) |
- |
100 |
|
- |
10.3(Core Identification by number ) |
- |
100 |
|
- |
10.4(Core Identification by number - Neutral ) |
- |
100 |
|
- |
11(LAVING UP OF CORES) |
- |
100 |
|
- |
12.1 & 12.2(Inner sheath : Application) |
- |
100 |
|
- |
12.3(Thickness of Inner Sheath) |
- |
300 |
|
- |
13.1(Armouring: Application) |
- |
100 |
|
- |
13.1.2(Armouring: Coverage ) |
- |
500 |
|
- |
13.1.3(Armouring: Direction of Lay ) |
- |
100 |
|
- |
13.3(Armouring : Dimensions -Wire Diameter) |
- |
200 |
|
- |
13.3(Armouring : Dimensions -Formed wire ) |
- |
200 |
|
- |
13.4(Armour: Joint) |
- |
100 |
|
- |
13.5(Armouring : Resistance Test) |
- |
300 |
|
- |
13.6 a)(ARMOURING: Tensile Strength) |
- |
300 |
|
- |
13.6 b)(ARMOURING: Elongation ) |
- |
300 |
|
- |
13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
300 |
|
- |
13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
300 |
|
- |
13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
300 |
|
- |
13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
300 |
|
- |
13.6 g)(ARMOURING: Resistivity) |
- |
300 |
|
- |
14.1(Outer Sheath : Application) |
- |
100 |
|
- |
14.3(Thickness of outer sheath - AVERAGE) |
- |
200 |
|
- |
14.3(Thickness of outer sheath - minimum) |
- |
200 |
|
- |
15.1 a) i)(Annealing Test ( For copper wire ) ) |
- |
300 |
|
- |
15.1 a) ii)(Tensile test (for aluminium) - Before stranding ) |
- |
300 |
|
- |
15.1 a) ii)(Tensile test (for aluminium) - After stranding ) |
- |
300 |
|
- |
15.1 a) iii)(Wrapping test (for aluminium)) |
- |
300 |
|
- |
15.1 a) iv)(Resistance test - Main conductor) |
- |
400 |
|
- |
15.1 a) iv)(Resistance test - Neutral conductor) |
- |
300 |
|
- |
15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
300 |
|
- |
15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
400 |
|
- |
15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
400 |
|
- |
15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
400 |
|
- |
15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
500 |
|
- |
15.1 d) iii) (Phyaical tests for insulation : Permanent set ) |
- |
200 |
|
- |
15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
300 |
|
- |
15.1 d) iv) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
300 |
|
- |
15.1 d) v) (Insulation: Waterabsorption(gravimetric)) |
- |
500 |
|
- |
15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
500 |
|
- |
15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
500 |
|
- |
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
500 |
|
- |
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
300 |
|
- |
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
300 |
|
- |
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
300 |
|
- |
15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
500 |
|
- |
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
500 |
|
- |
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
300 |
|
- |
15.1 e) v) (Sheath : Hot deformation) |
- |
200 |
|
- |
15.1 e) vi) (Sheath : Heat shock test) |
- |
300 |
|
- |
15.1 e) vii) (Sheath : Thermalstability) |
- |
300 |
|
- |
15.1 f)(INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
200 |
|
- |
16.2(HIGH VOLTAGE TEST ) |
- |
300 |
|
- |
16.3(FLAMMABILITY TEST : Period of Burning ) |
- |
200 |
|
- |
16.3(FLAMMABILITY TEST : Unaffected length ) |
- |
200 |
|
- |
16.9(Oxygen Index Test) |
- |
600 |
|
- |
16.1(Flame Retardance Test on Single Cables) |
- |
400 |
|
- |
16.11(Flame Retardance Test on Bunched Cables) |
- |
400 |
|
- |
16.13(Test for Halogen Acid Gas Evolution) |
- |
400 |
|
- |
16.14(Temperature Index) |
- |
400 |
|
- |
17.1(Manufacturer'. identification) |
- |
100 |
|
- |
17.2(cable Indentification ) |
- |
100 |
|
- |
17.3(cable Code ) |
- |
100 |
|
- |
15.4 (a)(Cold bend) |
- |
300 |
|
- |
15.4 (b)(Cold impact) |
- |
300 |
|
- |
Table 1(Ageing in air oven - Elongation on Insulation) |
- |
300 |
|
- |
Table 1(Ageing in air oven - Tensile strength on Insulation) |
- |
300 |
|
- |
Table 1(Ageing in air oven - Elongation on Insulation) |
- |
300 |
|
- |
Table 1(Ageing in air oven - Tensile strength on Insulation) |
- |
300 |
|
- |
Cl No. 16.15(Smoke density test) |
- |
300 |
|
- |
Table 2(Cold Impact test for Outer sheath) |
- |
300 |
|
- |
Table 2(Cold bend test for Outer sheath) |
- |
300 |
|
- |
Cl 16(Halogen Acid Gas Test) |
- |
200 |
|
- |
|
Complete
|
|
26 Sep, 2027 |
- - |
619 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
1100 |
-
|
13500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(MATERIALS : CONDUCTOR) |
- |
100 |
|
- |
4.1.1(INSULATION : General Purjose Insulaiion) |
- |
100 |
|
- |
4.1.2(INSULATION : Heat Resisting Insulation) |
- |
100 |
|
- |
5.1(MATERIALS : FILLER AND INNER SHEATH) |
- |
100 |
|
- |
5.2(MATERIALS : FILLER AND INNER SHEATH) |
- |
100 |
|
- |
6.1(MATERIALS : ARMGURING) |
- |
100 |
|
- |
6.2(MATERIALS : ARMGURING) |
- |
100 |
|
- |
7.1.1(OUTER SHEATH : For Cables with General Purpose InsuIafion) |
- |
100 |
|
- |
7.1.2(OUTER SHEATH : For Cables with Heat Resisting InsuIalion) |
- |
100 |
|
- |
8.1(CONSTRUCTION : CONDUCTOR) |
- |
100 |
|
- |
8.2(CONSTRUCTION : CONDUCTOR) |
- |
100 |
|
- |
9.1(INSULATION ) |
- |
100 |
|
- |
9.2(INSULATION : Thickness of Insulation) |
- |
200 |
|
- |
9.3(INSULATION :Tolerance on Thickness of Insulation) |
- |
200 |
|
- |
9.4(INSULATION : Application of Insulation) |
- |
100 |
|
- |
10.1(CORE IDENTIFICATION) |
- |
100 |
|
- |
10.2(CORE IDENTIFICATION) |
- |
100 |
|
- |
10.3(CORE IDENTIFICATION) |
- |
100 |
|
- |
10.3.1(Arrangement of Marking) |
- |
100 |
|
- |
11.1(LAYING UP OF CORES) |
- |
100 |
|
- |
11.2(LAYING UP OF CORES) |
- |
100 |
|
- |
12.1(INNER SHEATH) |
- |
100 |
|
- |
12.2(INNER SHEATH) |
- |
100 |
|
- |
12.3(INNER SHEATH :Thickness of Inner Sheath) |
- |
200 |
|
- |
13.1.1(ARMOURING : Application) |
- |
100 |
|
- |
13.1.2(Armouring: Coverage ) |
- |
100 |
|
- |
13.1.3(ARMOURING : Direction of lay ) |
- |
100 |
|
- |
13.1.4(ARMOURING : Application) |
- |
100 |
|
- |
13.2(ARMOURING : Type of Armour) |
- |
100 |
|
- |
13.2.1(ARMOURING : Type of Armour) |
- |
100 |
|
- |
13.3(Armouring : Dimensions -Wire Diameter) |
- |
200 |
|
- |
13.3(Armouring : Dimensions -Formed wire ) |
- |
200 |
|
- |
13.4(ARMOURING : Joints) |
- |
100 |
|
- |
13.5.1(ARMOURING : Resistance) |
- |
500 |
|
- |
13.5.2(ARMOURING : Resistance) |
- |
500 |
|
- |
13.6 a)(ARMOURING: Tensile Strength) |
- |
500 |
|
- |
13.6 b)(ARMOURING: Elongation ) |
- |
500 |
|
- |
13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
500 |
|
- |
13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
500 |
|
- |
13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
500 |
|
- |
13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
500 |
|
- |
13.6 g)(ARMOURING: Resistivity) |
- |
500 |
|
- |
14.1(OUTER SHEATH) |
- |
100 |
|
- |
14.2(OUTER SHEATH) |
- |
100 |
|
- |
14.3(OUTER SHEATH : Colour ) |
- |
100 |
|
- |
14.4.1(Thickness of Outer Sheath : Unarmowed Cables) |
- |
500 |
|
- |
14.4.2(Thickness of Outer Sheath : Armoured Cables) |
- |
500 |
|
- |
15.1 a) 1)(Tests on conductor : Annealing test ( for copper )) |
- |
500 |
|
- |
15.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
500 |
|
- |
15.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
500 |
|
- |
15.1 a) 3)(Tests on conductor : Wrapping test ( for aluminium )) |
- |
500 |
|
- |
15.1 a) 4)(Tests on conductor : Conductor resistance test) |
- |
500 |
|
- |
15.1 a) 4)(Resistance test - Neutral conductor ) |
- |
500 |
|
- |
15.1 d)1)(Phyaical tests for insulation : Tensile Test) |
- |
500 |
|
- |
15.1 d)1)(Phyaical tests for insulation : Elongation ) |
- |
500 |
|
- |
15.1 d)1)(Physical tests for sheath : Tensile stregth ) |
- |
500 |
|
- |
15.1 d)1)(Physical tests for sheath : Elongation ) |
- |
500 |
|
- |
15.1 d)2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
500 |
|
- |
15.1 d)2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
500 |
|
- |
15.1 d)2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
500 |
|
- |
15.1 d)2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
500 |
|
- |
15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
500 |
|
- |
15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
500 |
|
- |
15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
500 |
|
- |
15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
500 |
|
- |
15.1 d)3)(Phyaical tests for insulation : Shrinkage ) |
- |
500 |
|
- |
15.1 d)3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
100 |
|
- |
15.1 d)3)(Phyaical tests for Sheath : Shrinkage ) |
- |
500 |
|
- |
15.1 d)3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
100 |
|
- |
15.1 d)4)(Hot deformation : Insulation ) |
- |
500 |
|
- |
15.1 d)4)(Hot deformation : Sheath ) |
- |
500 |
|
- |
15.1 d)5)( Loss of mass in air oven- Insulation ) |
- |
500 |
|
- |
15.1 d)5)( Loss of mass in air oven- sheath ) |
- |
500 |
|
- |
15.1 d)6)(Heat shock test- Insulation ) |
- |
500 |
|
- |
15.1 d)6)(Heat shock test- sheath ) |
- |
500 |
|
- |
15.1 d)7)(Thermal stability- insulation ) |
- |
500 |
|
- |
15.1 d)7)(Thermal stability- Sheath ) |
- |
500 |
|
- |
15.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
500 |
|
- |
15.1 e)(Insulation resistance test : IR Constant ) |
- |
500 |
|
- |
15.1 f)(High voltage test ( water immersion test )) |
- |
500 |
|
- |
15.1 g)(High voltage test at room temperature) |
- |
500 |
|
- |
15.4 a)(Cold bend test- Insulation ( Optional test)) |
- |
500 |
|
- |
15.4 a)(Cold bend test- Sheath ( Optional test)) |
- |
500 |
|
- |
15.4 b)(Cold impact test- Insulation ( Optional test)) |
- |
500 |
|
- |
15.4 b)(Cold impact test- Sheath ( Optional test)) |
- |
500 |
|
- |
15.4 c)(Armour resistance test ( for other than mining cables ).- Optional test ) |
- |
500 |
|
- |
16.1(DETAILS OF TESTS : General) |
- |
100 |
|
- |
16.2(DETAILS OF TESTS : High Voltage Test at Room Temperature) |
- |
500 |
|
- |
16.3.1(High Voltage Test ( Water Immersion Test ) : a.c. Test) |
- |
500 |
|
- |
16.3.2(High Voltage Test ( Water Immersion Test ) : d.c. Test) |
- |
500 |
|
- |
16.4(Flammability Test) |
- |
500 |
|
- |
16.5(Oxygen Index Test) |
- |
500 |
|
- |
16.6(Flame Retardance Test on Single Cables) |
- |
500 |
|
- |
16.7(Flame Retardance Test on Bunched Cables) |
- |
500 |
|
- |
16.9(Test for Halogen Acid Gas Evolution) |
- |
500 |
|
- |
16.1(Temperature Index) |
- |
500 |
|
- |
17.1(IDENTIFICATION : Manufacturer’s Identification) |
- |
100 |
|
- |
17.2(IDENTIFICATION : Cable Identification) |
- |
100 |
|
- |
17.3(IDENTIFICATION : Cable Code) |
- |
100 |
|
- |
15.1.e(Insulation resistance Test- Insulation resistance At Maximum rated temperature temperature) |
- |
500 |
|
- |
15.1.e(Insulation resistance Test- Insulation resistance constant At Room temperature) |
- |
500 |
|
- |
15.1.e(Insulation resistance Test- Volume Resistivity At Maximum rated temperature temperature) |
- |
500 |
|
- |
15.1.e(Insulation resistance Test- Volume Resistivity At Room temperature) |
- |
500 |
|
- |
16.4(Flammability Test- Un affected portion) |
- |
100 |
|
- |
16.4(Flammability Test- Period of Burning) |
- |
500 |
|
- |
9.3(Minimum Thickness of Reduce core insulation) |
- |
200 |
|
- |
9.2(Thickness of Reduce core insulation) |
- |
200 |
|
- |
3.1 Table 2
IS 8130(Number of wires in the conductor) |
- |
100 |
|
- |
Cl No. 16.10(Smoke density test) |
- |
500 |
|
- |
|
Complete
|
|
26 Sep, 2027 |
- - |
620 |
Ace Test Labs & Metrology Pvt. Ltd.
| IS 14561 (2014) |
Fire resisting (Insulating) filing cabinets - Specification (Second Revision) |
- |
-
|
258000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3(Types & Rating) |
- |
5000 |
|
- |
3.1(i) The fire resisting filing cabinets shall be of two types:
a) Vertical fire resisting filing cabinet, and
b) Lateral fire resisting filing cabinet.) |
- |
5000 |
|
- |
3.2(ii) The standard and lateral fire resisting filing
cabinets shall have one-drawer or two-drawers or three drawers or four-drawers. A typical drawing of the fire resisting filing cabinet is given in Fig. 1.) |
- |
5000 |
|
- |
3.3(iii) The fire resisting filing cabinets shall have fire
resisting ratings of 60 min or 120 min or 180 min or
240 min) |
- |
5000 |
|
- |
4(Dimensions and Tolerances, mm) |
- |
5000 |
|
- |
4.1(Overall Dimensions of Fire Resisting Filing
Cabinets: The internal usable space of the drawers of fire resisting (insulating) filing cabinets shall be as specified in Table 1 or any other size which is mutually agreed to between the purchaser and the supplier.) |
- |
5000 |
|
- |
4.1(Internal usuable space of drawer, mm:) |
- |
5000 |
|
- |
4.1(i) Height) |
- |
5000 |
|
- |
4.1(ii) Width) |
- |
5000 |
|
- |
4.1(iii) Depth) |
- |
5000 |
|
- |
4.1(iv) Height of the bottom drawer above floor level) |
- |
5000 |
|
- |
5(Materials) |
- |
5000 |
|
- |
6(Designations: The filing cabinet shall be designated by the commonly used name, type, the fire rating and the number of this Indian Standard.) |
- |
5000 |
|
- |
7(Constructions) |
- |
15000 |
|
- |
7.1(Outer body and Inner Box: Outer body and inner box shall be fabricated from mild steel or galvanized steel sheets of not less than 0.8 mm and not more than 1.2 mm nominal thickness. The steel shall not have any burrs or dents. If required the outer
body shall be suitably stiffened to avoid bulging) |
- |
5000 |
|
- |
7.2(Cabinets Sub-Assembly: The external body and drawer fronts of the fire resisting (insulating) filing cabinet shall be of double wall type with homogeneous insulating material filled in
between. Further the construction of the cabinet shall be such that each drawer slides in an individual inner box. The inner boxes shall have a insulating layer between each other to prevent fire spreading from one drawer to another. The joining of inner box, intermediate piece and outer body shall be such that, it forms a cavity to receive drawer front ) |
- |
5000 |
|
- |
7.3(Filing Drawer: The drawer shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall have an arrangement on the sides suitable for the drawer suspension system and an arrangement to stop it when fully pushed in.) |
- |
5000 |
|
- |
7.3.1(Drawer Front: The drawer front shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall be firmly secured to the drawer body by welding, screwing or riveting or any combination of these processes. The construction of drawer front shall be such that it snugly fits in the cavity provided for the same ) |
- |
5000 |
|
- |
7.4.1(Latch: Each drawer of the cabinet shall be removable but shall be fitted with a latch/positive stop to prevent inadvertent withdrawal and rebound. Such latch shall be lifted/unlocked by the pull of the handle or any other mechanism.) |
- |
5000 |
|
- |
7.4.2(The locking mechanism shall be designed in such
a manner so that there is minimum passage for direct
conduction of heat from outside to inside) |
- |
5000 |
|
- |
7.5(Drawer Suspension The drawer suspension shall be either of the following types to ensure withdrawal of the full depth of the drawer:
a) Ball bearing / Roller bearing suspension
(Movement),
b) Solid roller suspension, and
c) Telescopic slide suspension (Extension) |
- |
5000 |
|
- |
7.6(Handles: Each drawer shall be provided either with a handle made from ferrous/non-ferrous material suitably coated for corrosion resistance, or any polymer and fixed to the front of the drawer or with a built in pulling mechanism) |
- |
5000 |
|
- |
7.6.1(The drawer handle shall be strong enough to take
a minimum pull of 50 N for 2 min. There shall be no
sharp corners or edges to avoid injury and damage to clothing) |
- |
5000 |
|
- |
7.7.1(Locks: Top drawer shall be provided with single or dual control key lock having not less than 6 levers or pin cylinder lock having not less than 6 pins, with duplicate keys of stainless steel/nonferrous alloy. Alternatively if required by the purchaser a 3 wheel combination lock or electronic combination lock may be provided either in place of key lock or in addition to key lock) |
- |
5000 |
|
- |
7.7.2(Each drawer may also be provided with
individual key lock or pin cylinder lock or combination lock subject to agreement between the purchaser and the supplier.) |
- |
5000 |
|
- |
7.8(Locking Mechanism ) |
- |
5000 |
|
- |
7.8.1(The locking mechanism shall be such that when
the top drawer is pushed-in fully, it actuates locking
mechanism to lock all other drawers imultaneously,
when they are in pushed-in position) |
- |
5000 |
|
- |
7.8.1.1(At the time of locking the cabinet, if one of the
drawers is not fully pushed-in, that drawer shall remain unlocked and can be used. As soon as that drawer is pushed-in fully, it shall get locked automatically without further operation of key by the user.) |
- |
5000 |
|
- |
7.8.1.2(In addition to the above, isolation mechanism
shall also be provided to permit independent locking/ use of other drawers. Such isolation mechanism provided on drawers shall be manually operated) |
- |
5000 |
|
- |
8(Assemblies) |
- |
5000 |
|
- |
8.1(The components shall be assembled by bolting,
welding, riveting or by any combination of these
processes) |
- |
5000 |
|
- |
8.2(All joints between outer body and inner boxes,
the drawer front and the outer body shall be such that, there is minimum direct conduction of heat from outer body to inner body) |
- |
5000 |
|
- |
9.1(Drawer Suspension Test and Latch Test: The drawer loaded with evenly distributed load of 30 kg
(excluding the weight of drawer) in any drawer shall be operated for 5 000 cycles at a rate of 300 cycles/h ±10 percent. One opening and one closing shall constitute one cycle. The test shall be carried out with maximum two breaks by using electrically or mechanically operated test equipment with a counter fitted on it. After 5 000 cycles the suspension slide and latch mechanism shall not show any apparent distortion, cracks, or failures to operate in a normal smooth manner) |
- |
5000 |
|
- |
10.1(Finish: All dents, burrs and sharp edges shall be removed from the various components and they shall be thoroughly degreased and cleaned of rust and scale) |
- |
5000 |
|
- |
10.2(The inside and outside surfaces of the fire resisting
(Insulating) filing cabinet shall be painted or powder coated. In case of paint, an appropriate primer and undercoating shall be used in accordance to industry practices. The minimum overall thickness of the coatings shall be 50 μ for powder coating and 70 μ for liquid paint. Cross hatch test shall be conducted to confirm the adhesion of coating in accordance with 10.2.1) |
- |
5000 |
|
- |
10.2.1(Cross Hatch Test) |
- |
5000 |
|
- |
10.2.1(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks) |
- |
5000 |
|
- |
10.2.1(b) Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other) |
- |
5000 |
|
- |
10.2.1(c) Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing) |
- |
5000 |
|
- |
10.2.1(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2mm size,
totally separated from each other) |
- |
5000 |
|
- |
10.2.1(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
5000 |
|
- |
10.2.1(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
5000 |
|
- |
10.2.1(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
5000 |
|
- |
11.1(Fire endurance test) |
- |
5000 |
|
- |
11.2(Fire and impact test) |
- |
5000 |
|
- |
12.1(Marking of Cabinets:A metal plate showing classification of cabinet together with the manufacturer’s name, serial number and the
year of manufacture shall be fixed inside surface of
the top drawer of the cabinet in such a way that it is
visible when it is opened.) |
- |
5000 |
|
- |
12.2(Marking on Keys: The keys shall bear an identification number which shall not be the same as the serial number of the cabinet) |
- |
5000 |
|
- |
3(Types & Rating) |
- |
5000 |
|
- |
3.1(i) The fire resisting filing cabinets shall be of two types:
a) Vertical fire resisting filing cabinet, and
b) Lateral fire resisting filing cabinet.) |
- |
5000 |
|
- |
3.2(ii) The standard and lateral fire resisting filing
cabinets shall have one-drawer or two-drawers or three drawers or four-drawers. A typical drawing of the fire resisting filing cabinet is given in Fig. 1.) |
- |
5000 |
|
- |
3.3(iii) The fire resisting filing cabinets shall have fire
resisting ratings of 60 min or 120 min or 180 min or
240 min) |
- |
5000 |
|
- |
4(Dimensions and Tolerances, mm) |
- |
5000 |
|
- |
4.1(Overall Dimensions of Fire Resisting Filing
Cabinets: The internal usable space of the drawers of fire resisting (insulating) filing cabinets shall be as specified in Table 1 or any other size which is mutually agreed to between the purchaser and the supplier.) |
- |
5000 |
|
- |
4.1(Internal usuable space of drawer, mm:) |
- |
5000 |
|
- |
4.1(i) Height) |
- |
5000 |
|
- |
4.1(ii) Width) |
- |
5000 |
|
- |
4.1(iii) Depth) |
- |
5000 |
|
- |
4.1(iv) Height of the bottom drawer above floor level) |
- |
5000 |
|
- |
5(Materials) |
- |
5000 |
|
- |
6(Designations: The filing cabinet shall be designated by the commonly used name, type, the fire rating and the number of this Indian Standard.) |
- |
5000 |
|
- |
7(Constructions) |
- |
5000 |
|
- |
7.1(Outer body and Inner Box: Outer body and inner box shall be fabricated from mild steel or galvanized steel sheets of not less than 0.8 mm and not more than 1.2 mm nominal thickness. The steel shall not have any burrs or dents. If required the outer
body shall be suitably stiffened to avoid bulging) |
- |
5000 |
|
- |
7.2(Cabinets Sub-Assembly: The external body and drawer fronts of the fire resisting (insulating) filing cabinet shall be of double wall type with homogeneous insulating material filled in
between. Further the construction of the cabinet shall be such that each drawer slides in an individual inner box. The inner boxes shall have a insulating layer between each other to prevent fire spreading from one drawer to another. The joining of inner box, intermediate piece and outer body shall be such that, it forms a cavity to receive drawer front ) |
- |
5000 |
|
- |
7.3(Filing Drawer: The drawer shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall have an arrangement on the sides suitable for the drawer suspension system and an arrangement to stop it when fully pushed in.) |
- |
5000 |
|
- |
7.3.1(Drawer Front: The drawer front shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall be firmly secured to the drawer body by welding, screwing or riveting or any combination of these processes. The construction of drawer front shall be such that it snugly fits in the cavity provided for the same ) |
- |
5000 |
|
- |
7.4.1(Latch: Each drawer of the cabinet shall be removable but shall be fitted with a latch/positive stop to prevent inadvertent withdrawal and rebound. Such latch shall be lifted/unlocked by the pull of the handle or any other mechanism.) |
- |
5000 |
|
- |
7.4.2(The locking mechanism shall be designed in such
a manner so that there is minimum passage for direct
conduction of heat from outside to inside) |
- |
5000 |
|
- |
7.5(Drawer Suspension The drawer suspension shall be either of the following types to ensure withdrawal of the full depth of the drawer:
a) Ball bearing / Roller bearing suspension
(Movement),
b) Solid roller suspension, and
c) Telescopic slide suspension (Extension) |
- |
5000 |
|
- |
7.6(Handles: Each drawer shall be provided either with a handle made from ferrous/non-ferrous material suitably coated for corrosion resistance, or any polymer and fixed to the front of the drawer or with a built in pulling mechanism) |
- |
5000 |
|
- |
7.6.1(The drawer handle shall be strong enough to take
a minimum pull of 50 N for 2 min. There shall be no
sharp corners or edges to avoid injury and damage to clothing) |
- |
5000 |
|
- |
7.7.1(Locks: Top drawer shall be provided with single or dual control key lock having not less than 6 levers or pin cylinder lock having not less than 6 pins, with duplicate keys of stainless steel/nonferrous alloy. Alternatively if required by the purchaser a 3 wheel combination lock or electronic combination lock may be provided either in place of key lock or in addition to key lock) |
- |
5000 |
|
- |
7.7.2(Each drawer may also be provided with
individual key lock or pin cylinder lock or combination lock subject to agreement between the purchaser and the supplier.) |
- |
5000 |
|
- |
7.8(Locking Mechanism ) |
- |
5000 |
|
- |
7.8.1(The locking mechanism shall be such that when
the top drawer is pushed-in fully, it actuates locking
mechanism to lock all other drawers imultaneously,
when they are in pushed-in position) |
- |
5000 |
|
- |
7.8.1.1(At the time of locking the cabinet, if one of the
drawers is not fully pushed-in, that drawer shall remain unlocked and can be used. As soon as that drawer is pushed-in fully, it shall get locked automatically without further operation of key by the user.) |
- |
5000 |
|
- |
7.8.1.2(In addition to the above, isolation mechanism
shall also be provided to permit independent locking/ use of other drawers. Such isolation mechanism provided on drawers shall be manually operated) |
- |
5000 |
|
- |
8(Assemblies) |
- |
5000 |
|
- |
8.1(The components shall be assembled by bolting,
welding, riveting or by any combination of these
processes) |
- |
5000 |
|
- |
8.2(All joints between outer body and inner boxes,
the drawer front and the outer body shall be such that, there is minimum direct conduction of heat from outer body to inner body) |
- |
5000 |
|
- |
9.1(Drawer Suspension Test and Latch Test: The drawer loaded with evenly distributed load of 30 kg
(excluding the weight of drawer) in any drawer shall be operated for 5 000 cycles at a rate of 300 cycles/h ±10 percent. One opening and one closing shall constitute one cycle. The test shall be carried out with maximum two breaks by using electrically or mechanically operated test equipment with a counter fitted on it. After 5 000 cycles the suspension slide and latch mechanism shall not show any apparent distortion, cracks, or failures to operate in a normal smooth manner) |
- |
5000 |
|
- |
10.1(Finish: All dents, burrs and sharp edges shall be removed from the various components and they shall be thoroughly degreased and cleaned of rust and scale) |
- |
5000 |
|
- |
10.2(The inside and outside surfaces of the fire resisting
(Insulating) filing cabinet shall be painted or powder coated. In case of paint, an appropriate primer and undercoating shall be used in accordance to industry practices. The minimum overall thickness of the coatings shall be 50 μ for powder coating and 70 μ for liquid paint. Cross hatch test shall be conducted to confirm the adhesion of coating in accordance with 10.2.1) |
- |
5000 |
|
- |
10.2.1(Cross Hatch Test) |
- |
5000 |
|
- |
10.2.1(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks) |
- |
5000 |
|
- |
10.2.1(b) Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other) |
- |
5000 |
|
- |
10.2.1(c) Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing) |
- |
5000 |
|
- |
10.2.1(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2mm size,
totally separated from each other) |
- |
5000 |
|
- |
10.2.1(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
5000 |
|
- |
10.2.1(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
5000 |
|
- |
10.2.1(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
5000 |
|
- |
11.1(Fire endurance test) |
- |
150000 |
|
- |
11.2(Fire and impact test) |
- |
150000 |
|
- |
12.1(Marking of Cabinets:A metal plate showing classification of cabinet together with the manufacturer’s name, serial number and the
year of manufacture shall be fixed inside surface of
the top drawer of the cabinet in such a way that it is
visible when it is opened.) |
- |
15000 |
|
- |
12.2(Marking on Keys: The keys shall bear an identification number which shall not be the same as the serial number of the cabinet) |
- |
15000 |
|
- |
3(Types & Rating) |
- |
15000 |
|
- |
3.1(i) The fire resisting filing cabinets shall be of two types:
a) Vertical fire resisting filing cabinet, and
b) Lateral fire resisting filing cabinet.) |
- |
15000 |
|
- |
3.2(ii) The standard and lateral fire resisting filing
cabinets shall have one-drawer or two-drawers or three drawers or four-drawers. A typical drawing of the fire resisting filing cabinet is given in Fig. 1.) |
- |
15000 |
|
- |
3.3(iii) The fire resisting filing cabinets shall have fire
resisting ratings of 60 min or 120 min or 180 min or
240 min) |
- |
15000 |
|
- |
4(Dimensions and Tolerances, mm) |
- |
15000 |
|
- |
4.1(Overall Dimensions of Fire Resisting Filing
Cabinets: The internal usable space of the drawers of fire resisting (insulating) filing cabinets shall be as specified in Table 1 or any other size which is mutually agreed to between the purchaser and the supplier.) |
- |
15000 |
|
- |
4.1(Internal usuable space of drawer, mm:) |
- |
15000 |
|
- |
4.1(i) Height) |
- |
15000 |
|
- |
4.1(ii) Width) |
- |
15000 |
|
- |
4.1(iii) Depth) |
- |
15000 |
|
- |
4.1(iv) Height of the bottom drawer above floor level) |
- |
15000 |
|
- |
5(Materials) |
- |
15000 |
|
- |
6(Designations: The filing cabinet shall be designated by the commonly used name, type, the fire rating and the number of this Indian Standard.) |
- |
15000 |
|
- |
7(Constructions) |
- |
15000 |
|
- |
7.1(Outer body and Inner Box: Outer body and inner box shall be fabricated from mild steel or galvanized steel sheets of not less than 0.8 mm and not more than 1.2 mm nominal thickness. The steel shall not have any burrs or dents. If required the outer
body shall be suitably stiffened to avoid bulging) |
- |
15000 |
|
- |
7.2(Cabinets Sub-Assembly: The external body and drawer fronts of the fire resisting (insulating) filing cabinet shall be of double wall type with homogeneous insulating material filled in
between. Further the construction of the cabinet shall be such that each drawer slides in an individual inner box. The inner boxes shall have a insulating layer between each other to prevent fire spreading from one drawer to another. The joining of inner box, intermediate piece and outer body shall be such that, it forms a cavity to receive drawer front ) |
- |
15000 |
|
- |
7.3(Filing Drawer: The drawer shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall have an arrangement on the sides suitable for the drawer suspension system and an arrangement to stop it when fully pushed in.) |
- |
15000 |
|
- |
7.3.1(Drawer Front: The drawer front shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall be firmly secured to the drawer body by welding, screwing or riveting or any combination of these processes. The construction of drawer front shall be such that it snugly fits in the cavity provided for the same ) |
- |
15000 |
|
- |
7.4.1(Latch: Each drawer of the cabinet shall be removable but shall be fitted with a latch/positive stop to prevent inadvertent withdrawal and rebound. Such latch shall be lifted/unlocked by the pull of the handle or any other mechanism.) |
- |
15000 |
|
- |
7.4.2(The locking mechanism shall be designed in such
a manner so that there is minimum passage for direct
conduction of heat from outside to inside) |
- |
15000 |
|
- |
7.5(Drawer Suspension The drawer suspension shall be either of the following types to ensure withdrawal of the full depth of the drawer:
a) Ball bearing / Roller bearing suspension
(Movement),
b) Solid roller suspension, and
c) Telescopic slide suspension (Extension) |
- |
15000 |
|
- |
7.6(Handles: Each drawer shall be provided either with a handle made from ferrous/non-ferrous material suitably coated for corrosion resistance, or any polymer and fixed to the front of the drawer or with a built in pulling mechanism) |
- |
15000 |
|
- |
7.6.1(The drawer handle shall be strong enough to take
a minimum pull of 50 N for 2 min. There shall be no
sharp corners or edges to avoid injury and damage to clothing) |
- |
15000 |
|
- |
7.7.1(Locks: Top drawer shall be provided with single or dual control key lock having not less than 6 levers or pin cylinder lock having not less than 6 pins, with duplicate keys of stainless steel/nonferrous alloy. Alternatively if required by the purchaser a 3 wheel combination lock or electronic combination lock may be provided either in place of key lock or in addition to key lock) |
- |
15000 |
|
- |
7.7.2(Each drawer may also be provided with
individual key lock or pin cylinder lock or combination lock subject to agreement between the purchaser and the supplier.) |
- |
15000 |
|
- |
7.8(Locking Mechanism ) |
- |
15000 |
|
- |
7.8.1(The locking mechanism shall be such that when
the top drawer is pushed-in fully, it actuates locking
mechanism to lock all other drawers imultaneously,
when they are in pushed-in position) |
- |
15000 |
|
- |
7.8.1.1(At the time of locking the cabinet, if one of the
drawers is not fully pushed-in, that drawer shall remain unlocked and can be used. As soon as that drawer is pushed-in fully, it shall get locked automatically without further operation of key by the user.) |
- |
15000 |
|
- |
7.8.1.2(In addition to the above, isolation mechanism
shall also be provided to permit independent locking/ use of other drawers. Such isolation mechanism provided on drawers shall be manually operated) |
- |
15000 |
|
- |
8(Assemblies) |
- |
15000 |
|
- |
8.1(The components shall be assembled by bolting,
welding, riveting or by any combination of these
processes) |
- |
15000 |
|
- |
8.2(All joints between outer body and inner boxes,
the drawer front and the outer body shall be such that, there is minimum direct conduction of heat from outer body to inner body) |
- |
15000 |
|
- |
9.1(Drawer Suspension Test and Latch Test: The drawer loaded with evenly distributed load of 30 kg
(excluding the weight of drawer) in any drawer shall be operated for 5 000 cycles at a rate of 300 cycles/h ±10 percent. One opening and one closing shall constitute one cycle. The test shall be carried out with maximum two breaks by using electrically or mechanically operated test equipment with a counter fitted on it. After 5 000 cycles the suspension slide and latch mechanism shall not show any apparent distortion, cracks, or failures to operate in a normal smooth manner) |
- |
15000 |
|
- |
10.1(Finish: All dents, burrs and sharp edges shall be removed from the various components and they shall be thoroughly degreased and cleaned of rust and scale) |
- |
15000 |
|
- |
10.2(The inside and outside surfaces of the fire resisting
(Insulating) filing cabinet shall be painted or powder coated. In case of paint, an appropriate primer and undercoating shall be used in accordance to industry practices. The minimum overall thickness of the coatings shall be 50 μ for powder coating and 70 μ for liquid paint. Cross hatch test shall be conducted to confirm the adhesion of coating in accordance with 10.2.1) |
- |
15000 |
|
- |
10.2.1(Cross Hatch Test) |
- |
15000 |
|
- |
10.2.1(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks) |
- |
15000 |
|
- |
10.2.1(b) Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other) |
- |
15000 |
|
- |
10.2.1(c) Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing) |
- |
15000 |
|
- |
10.2.1(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2mm size,
totally separated from each other) |
- |
15000 |
|
- |
10.2.1(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
15000 |
|
- |
10.2.1(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
15000 |
|
- |
10.2.1(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
15000 |
|
- |
11.1(Fire endurance test) |
- |
15000 |
|
- |
11.2(Fire and impact test) |
- |
15000 |
|
- |
12.1(Marking of Cabinets:A metal plate showing classification of cabinet together with the manufacturer’s name, serial number and the
year of manufacture shall be fixed inside surface of
the top drawer of the cabinet in such a way that it is
visible when it is opened.) |
- |
15000 |
|
- |
12.2(Marking on Keys: The keys shall bear an identification number which shall not be the same as the serial number of the cabinet) |
- |
15000 |
|
- |
3(Types & Rating) |
- |
15000 |
|
- |
3.1(i) The fire resisting filing cabinets shall be of two types:
a) Vertical fire resisting filing cabinet, and
b) Lateral fire resisting filing cabinet.) |
- |
15000 |
|
- |
3.2(ii) The standard and lateral fire resisting filing
cabinets shall have one-drawer or two-drawers or three drawers or four-drawers. A typical drawing of the fire resisting filing cabinet is given in Fig. 1.) |
- |
15000 |
|
- |
3.3(iii) The fire resisting filing cabinets shall have fire
resisting ratings of 60 min or 120 min or 180 min or
240 min) |
- |
15000 |
|
- |
4(Dimensions and Tolerances, mm) |
- |
15000 |
|
- |
4.1(Overall Dimensions of Fire Resisting Filing
Cabinets: The internal usable space of the drawers of fire resisting (insulating) filing cabinets shall be as specified in Table 1 or any other size which is mutually agreed to between the purchaser and the supplier.) |
- |
15000 |
|
- |
4.1(Internal usuable space of drawer, mm:) |
- |
15000 |
|
- |
4.1(i) Height) |
- |
15000 |
|
- |
4.1(ii) Width) |
- |
15000 |
|
- |
4.1(iii) Depth) |
- |
15000 |
|
- |
4.1(iv) Height of the bottom drawer above floor level) |
- |
15000 |
|
- |
5(Materials) |
- |
15000 |
|
- |
6(Designations: The filing cabinet shall be designated by the commonly used name, type, the fire rating and the number of this Indian Standard.) |
- |
15000 |
|
- |
7(Constructions) |
- |
15000 |
|
- |
7.1(Outer body and Inner Box: Outer body and inner box shall be fabricated from mild steel or galvanized steel sheets of not less than 0.8 mm and not more than 1.2 mm nominal thickness. The steel shall not have any burrs or dents. If required the outer
body shall be suitably stiffened to avoid bulging) |
- |
15000 |
|
- |
7.2(Cabinets Sub-Assembly: The external body and drawer fronts of the fire resisting (insulating) filing cabinet shall be of double wall type with homogeneous insulating material filled in
between. Further the construction of the cabinet shall be such that each drawer slides in an individual inner box. The inner boxes shall have a insulating layer between each other to prevent fire spreading from one drawer to another. The joining of inner box, intermediate piece and outer body shall be such that, it forms a cavity to receive drawer front ) |
- |
15000 |
|
- |
7.3(Filing Drawer: The drawer shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall have an arrangement on the sides suitable for the drawer suspension system and an arrangement to stop it when fully pushed in.) |
- |
15000 |
|
- |
7.3.1(Drawer Front: The drawer front shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall be firmly secured to the drawer body by welding, screwing or riveting or any combination of these processes. The construction of drawer front shall be such that it snugly fits in the cavity provided for the same ) |
- |
15000 |
|
- |
7.4.1(Latch: Each drawer of the cabinet shall be removable but shall be fitted with a latch/positive stop to prevent inadvertent withdrawal and rebound. Such latch shall be lifted/unlocked by the pull of the handle or any other mechanism.) |
- |
15000 |
|
- |
7.4.2(The locking mechanism shall be designed in such
a manner so that there is minimum passage for direct
conduction of heat from outside to inside) |
- |
15000 |
|
- |
7.5(Drawer Suspension The drawer suspension shall be either of the following types to ensure withdrawal of the full depth of the drawer:
a) Ball bearing / Roller bearing suspension
(Movement),
b) Solid roller suspension, and
c) Telescopic slide suspension (Extension) |
- |
15000 |
|
- |
7.6(Handles: Each drawer shall be provided either with a handle made from ferrous/non-ferrous material suitably coated for corrosion resistance, or any polymer and fixed to the front of the drawer or with a built in pulling mechanism) |
- |
15000 |
|
- |
7.6.1(The drawer handle shall be strong enough to take
a minimum pull of 50 N for 2 min. There shall be no
sharp corners or edges to avoid injury and damage to clothing) |
- |
15000 |
|
- |
7.7.1(Locks: Top drawer shall be provided with single or dual control key lock having not less than 6 levers or pin cylinder lock having not less than 6 pins, with duplicate keys of stainless steel/nonferrous alloy. Alternatively if required by the purchaser a 3 wheel combination lock or electronic combination lock may be provided either in place of key lock or in addition to key lock) |
- |
15000 |
|
- |
7.7.2(Each drawer may also be provided with
individual key lock or pin cylinder lock or combination lock subject to agreement between the purchaser and the supplier.) |
- |
15000 |
|
- |
7.8(Locking Mechanism ) |
- |
15000 |
|
- |
7.8.1(The locking mechanism shall be such that when
the top drawer is pushed-in fully, it actuates locking
mechanism to lock all other drawers imultaneously,
when they are in pushed-in position) |
- |
15000 |
|
- |
7.8.1.1(At the time of locking the cabinet, if one of the
drawers is not fully pushed-in, that drawer shall remain unlocked and can be used. As soon as that drawer is pushed-in fully, it shall get locked automatically without further operation of key by the user.) |
- |
15000 |
|
- |
7.8.1.2(In addition to the above, isolation mechanism
shall also be provided to permit independent locking/ use of other drawers. Such isolation mechanism provided on drawers shall be manually operated) |
- |
15000 |
|
- |
8(Assemblies) |
- |
15000 |
|
- |
8.1(The components shall be assembled by bolting,
welding, riveting or by any combination of these
processes) |
- |
15000 |
|
- |
8.2(All joints between outer body and inner boxes,
the drawer front and the outer body shall be such that, there is minimum direct conduction of heat from outer body to inner body) |
- |
15000 |
|
- |
9.1(Drawer Suspension Test and Latch Test: The drawer loaded with evenly distributed load of 30 kg
(excluding the weight of drawer) in any drawer shall be operated for 5 000 cycles at a rate of 300 cycles/h ±10 percent. One opening and one closing shall constitute one cycle. The test shall be carried out with maximum two breaks by using electrically or mechanically operated test equipment with a counter fitted on it. After 5 000 cycles the suspension slide and latch mechanism shall not show any apparent distortion, cracks, or failures to operate in a normal smooth manner) |
- |
15000 |
|
- |
10.1(Finish: All dents, burrs and sharp edges shall be removed from the various components and they shall be thoroughly degreased and cleaned of rust and scale) |
- |
15000 |
|
- |
10.2(The inside and outside surfaces of the fire resisting
(Insulating) filing cabinet shall be painted or powder coated. In case of paint, an appropriate primer and undercoating shall be used in accordance to industry practices. The minimum overall thickness of the coatings shall be 50 μ for powder coating and 70 μ for liquid paint. Cross hatch test shall be conducted to confirm the adhesion of coating in accordance with 10.2.1) |
- |
15000 |
|
- |
10.2.1(Cross Hatch Test) |
- |
15000 |
|
- |
10.2.1(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks) |
- |
15000 |
|
- |
10.2.1(b) Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other) |
- |
15000 |
|
- |
10.2.1(c) Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing) |
- |
15000 |
|
- |
10.2.1(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2mm size,
totally separated from each other) |
- |
15000 |
|
- |
10.2.1(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
15000 |
|
- |
10.2.1(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
15000 |
|
- |
10.2.1(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
15000 |
|
- |
11.1(Fire endurance test) |
- |
150000 |
|
- |
11.2(Fire and impact test) |
- |
150000 |
|
- |
12.1(Marking of Cabinets:A metal plate showing classification of cabinet together with the manufacturer’s name, serial number and the
year of manufacture shall be fixed inside surface of
the top drawer of the cabinet in such a way that it is
visible when it is opened.) |
- |
5000 |
|
- |
12.2(Marking on Keys: The keys shall bear an identification number which shall not be the same as the serial number of the cabinet) |
- |
5000 |
|
- |
|
Complete
|
|
14 Nov, 2027 |
- Included w.e.f. 28.03.2025 |
621 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
1100 |
-
|
13000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
13(Cable code) |
- |
200 |
|
- |
11.2(Legibility) |
- |
200 |
|
- |
11.1(Durability) |
- |
200 |
|
- |
11(Identification) |
- |
200 |
|
- |
10.9(Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
1000 |
|
- |
10.4(Flammability test- Unaffected portion) |
- |
1000 |
|
- |
10.4(Flammability test-Burning after flame removal) |
- |
200 |
|
- |
table 1 e) 3) (IR constant- max. Temp) |
- |
500 |
|
- |
table 1 e) 3) (IR constant- Room temp ) |
- |
500 |
|
- |
table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
500 |
|
- |
table 1 e) 3) (Volume Resistivity - Room temp ) |
- |
500 |
|
- |
10.2(HV (room temperature)) |
- |
500 |
|
- |
10.1(HV (water immersion)) |
- |
500 |
|
- |
10.1(HV (water immersion)) |
- |
500 |
|
- |
10.8(Smoke density rating) |
- |
500 |
|
- |
10.6(Halogen evolution) |
- |
500 |
|
- |
10.7(Temperature index) |
- |
500 |
|
- |
10.5(Oxygen index) |
- |
500 |
|
- |
Table 1 iii) d) 9)(Cold impact for sheath) |
- |
500 |
|
- |
Table 1 iii) d) 8)(Cold bend for sheath) |
- |
500 |
|
- |
Table 1 iii) c) 9)(Cold impact for insulation) |
- |
500 |
|
- |
Table 1 iii) c) 8)(Cold bend for insulation) |
- |
500 |
|
- |
Table 1 iii) d) 7)(Thermal stability- Sheath ) |
- |
500 |
|
- |
Table 1 iii) c) 7)(Thermal stability- Insulation ) |
- |
500 |
|
- |
Table 1 iii) d) 6)(Hot deformation -Indentation depth - Sheath ) |
- |
500 |
|
- |
Table 1 iii) c) 6)(Hot deformation - Indentation depth- Insulation) |
- |
500 |
|
- |
Table 1 iii) d) 5)(Heat shock-Sheath ) |
- |
500 |
|
- |
Table 1 iii) c) 5)(Heat shock-Insulation ) |
- |
500 |
|
- |
Table 1 iii) d) 4)(Shrinkage- Sheath ) |
- |
500 |
|
- |
Table 1 iii) c) 4)(Shrinkage-Insulation) |
- |
500 |
|
- |
Table 1 iii) d) 2)(Loss of mass- Sheath ) |
- |
1000 |
|
- |
Table 1 iii) c) 2)(Loss of mass- Insulation ) |
- |
1000 |
|
- |
Table 1 iii) d) 3)(Sheath- Elongation variation) |
- |
500 |
|
- |
Table 1 iii) d) 3)(Sheath- TS variation) |
- |
500 |
|
- |
Table 1 iii) d) 3)(Sheath- Elongation (After ageing)) |
- |
500 |
|
- |
Table 1 iii) d) 3)(Sheath- Tensile strength (After ageing)) |
- |
500 |
|
- |
Table 1 iii) d) 1)(Sheath- Elongation (Without ageing)) |
- |
500 |
|
- |
Table 1 iii) d) 1)(Sheath -Tensile strength (Without ageing)) |
- |
500 |
|
- |
Table 1 iii) c) 3)(Elongation variation) |
- |
500 |
|
- |
Table 1 iii) c) 3)(TS variation) |
- |
500 |
|
- |
Table 1 iii) c) 3)(Elongation (After ageing)) |
- |
500 |
|
- |
Table 1 iii) c) 3)(Tensile strength (After ageing)) |
- |
500 |
|
- |
Table 1 iii) c) 1)(Elongation (Without ageing)) |
- |
500 |
|
- |
Table 1 iii) c) 1)(Tensile strength (Without ageing)) |
- |
500 |
|
- |
(Cl. 18.1.4)
(Cl. 19.1.5)
(Cl. 20.1.4)
(Cl. 22.1.4)(Colour of Sheath) |
- |
200 |
|
- |
8.3(Thickness of Sheath) |
- |
200 |
|
- |
5.2(Application ) |
- |
200 |
|
- |
5.3(Thickness of Insulation) |
- |
200 |
|
- |
9.1(Ovality) |
- |
200 |
|
- |
9(Overall dimensions) |
- |
200 |
|
- |
10.11(Per sulphate test (for tinned Cu cable only)) |
- |
800 |
|
- |
4.2(Conductor resistance test) |
- |
800 |
|
- |
4.1(Wrapping test (for Al)) |
- |
500 |
|
- |
4.1(Tensile test (for Al)- After Stranding) |
- |
500 |
|
- |
4.1(Tensile test (for Al)-Before Stranding) |
- |
500 |
|
- |
4.1(Annealing test (for copper)) |
- |
500 |
|
- |
(Cl.6.1.3 of IS 8130:2013)(Flexible Conductors (Classes 5)) |
- |
200 |
|
- |
(Cl.6.1.3 of IS 8130:2013)(Stranded circular non compacted conductors(Class-2)) |
- |
200 |
|
- |
(Cl.6.1.3 of IS 8130:2013)(Stranded compacted circular conductors and shaped conductors (Class 2)) |
- |
200 |
|
- |
(Cl.6.1.3 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
200 |
|
- |
(Cl.16.1)
(Cl.19.1)(Conductor- Diameter ) |
- |
200 |
|
- |
(Cl. 18.1.3)
(Cl. 19.1.4)
(Cl. 20.1.3)
(Cl. 21.1.3)
(Cl. 22.1.3)(Assembly of cores ) |
- |
200 |
|
- |
12(CONSTRUCTION Core Identification) |
- |
200 |
|
- |
8.1(Sheath Material ) |
- |
200 |
|
- |
7(Binder Tape) |
- |
200 |
|
- |
6.2(Filler) |
- |
200 |
|
- |
5.1(Insulation) |
- |
200 |
|
- |
4.4(Joints in Conductor) |
- |
200 |
|
- |
4.1(Conductor - Material) |
- |
200 |
|
- |
10.11(Persulphate Test ) |
- |
800 |
|
- |
12.0(Core identification) |
- |
200 |
|
- |
4, IS 8130(Construction of conductor) |
- |
200 |
|
- |
Table 2, IS 8130(No fo wire in a conductor) |
- |
200 |
|
- |
8.3(Minimum thickness of Sheath) |
- |
500 |
|
- |
8.3(Avarage thickness of Sheath) |
- |
500 |
|
- |
5.3(Minimum thickness of insulation) |
- |
500 |
|
- |
5.3(Avarage thickness of insulation) |
- |
500 |
|
- |
table 1, 4.2(insulation resistance test) |
- |
500 |
|
- |
|
Complete
|
|
26 Sep, 2027 |
- - |
622 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 21 (1992) |
Wrought aluminium and aluminium alloys for manufacture of utensils specification (Fourth Revision) |
- |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1, & 4.1.1(Lead) |
- |
1500 |
|
- |
4.1.2(Aluminium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 64430)(Aluminium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 64430)(Lead) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 64430)(Chromium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 64430)(Titanium and or other grain refining elements) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 64430)(Zinc) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 64430)(Manganese) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 64430)(Iron) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 40800)(Silicon) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 64430)(Magnesium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 64430)(Copper) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 51000-B)(Aluminium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 51000-B)(Lead) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 51000-B)(Chromium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 51000-B)(Zinc) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 51000-B)(Manganese) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 51000-B)(Iron) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 51000-B)(Silicon) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 51000-B)(Magnesium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 51000-B)(Copper) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 51000-A)(Aluminium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 51000-A)(Lead) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 51000-A)(Chromium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 51000-A)(Zinc) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 51000-A)(Manganese) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 51000-A)(Iron) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 51000-A)(Silicon) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 51000-A)(Magnesium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 51000-A)(Copper) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 40800)(Aluminium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 40800)(Lead) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 40800)(Titanium and or other grain refining elements) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 40800)(Zinc) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 40800)(Manganese) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 40800)(Iron) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 40800)(Magnesium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 40800)(Copper) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 31500)(Aluminium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 31500)(Titanium and or other grain refining elements) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 31500)(Lead) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 31500)(Zinc) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 31500)(Manganese) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 31500)(Iron) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 31500)(Silicon) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 31500)(Magnesium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 31500)(Copper) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Aluminium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Lead) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Chromium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Titanium and or other grain refining elements) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Zinc) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Manganese) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Iron) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Silicon) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Magnesium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Copper) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19600)(Aluminium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19600)(Cu+Si+Fe+Mn+Zn) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19500)(Aluminium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19500)(Cu+Si+Fe+Mn+Zn) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19000)(Cu+Mg+Si+Fe+Mn+Zn) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19000)(Aluminium) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19600)(Lead) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19500)(Lead) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19000)(Lead) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19600)(Zinc) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19500)(Zinc) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19000)(Zinc) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19600)(Manganese) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19500)(Manganese) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19000)(Manganese) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19600)(Iron) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19500)(Iron) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19000)(Iron) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19600)(Silicon) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19500)(Silicon) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19000)(Silicon) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19600)(Copper) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19500)(Copper) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19000)(Copper) |
- |
800 |
|
- |
4.2,
Table 1of IS:21 (Designation 19000)(Magnesium) |
- |
800 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 64430, WP')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'W')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'O')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H3')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H1')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H3')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H1')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'O')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H3')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H1')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'O')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H3')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H1')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'O')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H3')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H1')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'O')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'O')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'O')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H3')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H1')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'O')(Tensile Strength) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 64430, WP')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'W')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H3')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H2')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H1')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H3')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H2')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H1')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 64430, WP')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'W')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H3')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H3')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H3')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H3')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H3')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H3')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 64430, WP')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'W')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H3')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H1')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H3')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H1')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H3')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H1')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H3')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H1')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H3')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H1')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H3')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H1')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
5(Marking) |
- |
300 |
|
- |
|
Complete
|
|
26 Sep, 2027 |
- - |
623 |
Ace Test Labs & Metrology Pvt. Ltd.
| IS 11188 : Part 1 (2021) |
Vault Strong Room doors Part 1 specification |
- |
-
|
298000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
11.1 (3)(Fire and stream hose IS 11188 (Part 3)) |
- |
15000 |
|
- |
11.1 (2)(Fire endurance IS 11188 (Part 3)) |
- |
150000 |
|
- |
11.1 (1)(Burglary resistance IS 11188 (Part 2)) |
- |
150000 |
|
- |
10.4(Alternate to Cl 10.4) |
- |
15000 |
|
- |
10.3(Cross Hatch Test) |
- |
15000 |
|
- |
10(FINISH) |
- |
15000 |
|
- |
9.4(Vault Lighting Control) |
- |
15000 |
|
- |
9.3(Foot Bridge) |
- |
15000 |
|
- |
9.2(Handles) |
- |
15000 |
|
- |
9.1.1(Adjusting Bolt) |
- |
15000 |
|
- |
9.1(Hinges) |
- |
15000 |
|
- |
9(DOOR FITTINGS) |
- |
15000 |
|
- |
8.4.5(Automatic Relocking Device) |
- |
15000 |
|
- |
8.4.4(Time Lock) |
- |
15000 |
|
- |
8.4(Lock) |
- |
15000 |
|
- |
8.3.2.2(Construction) |
- |
15000 |
|
- |
8.3.2.1(The number of bolts and their minimum dimension) |
- |
15000 |
|
- |
8.3.2(Bolt Work) |
- |
15000 |
|
- |
8.3.1(Lock Case) |
- |
15000 |
|
- |
8.3(Locking Mechanism) |
- |
15000 |
|
- |
8.2.3(Crane Hinge Mechanism) |
- |
15000 |
|
- |
8.2.2(Compression Mechanism) |
- |
15000 |
|
- |
8.2.1(Rebate of the Door Frame) |
- |
15000 |
|
- |
8.2(Doors Frame) |
- |
15000 |
|
- |
8.1.2(Main Door (Outside)) |
- |
15000 |
|
- |
8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
8.1 Fig. 1(Doors) |
- |
15000 |
|
- |
8(CONSTRUCTION AND GENERALREQUIREMENTS) |
- |
15000 |
|
- |
5 Table 1(bolts, Min) |
- |
15000 |
|
- |
5 Table 1(xix) Depth of engagement of shooting) |
- |
15000 |
|
- |
5 Table 1(cross sectional area, Min,sq mm) |
- |
15000 |
|
- |
5 Table 1(xviii) Diameter of shooting bolts, Min) |
- |
15000 |
|
- |
5 Table 1(xvi) Number of shooting bolts at top,Min) |
- |
15000 |
|
- |
5 Table 1(xv) Number of shooting bolts on opposite side,Min) |
- |
15000 |
|
- |
5 Table 1(xiv) Number of shooting bolts on hinge side, Min) |
- |
15000 |
|
- |
5 Table 1(xiii) Number of locks) |
- |
15000 |
|
- |
5 Table 1(xii) Wall thickness (recommendation)) |
- |
15000 |
|
- |
5 Table 1(xi) Thickness of drill and oxyacetylene
torch resisting layer (excluding mild steel plates),Min) |
- |
15000 |
|
- |
5 Table 1(ix) Thickness of doors slab, thickness over rebate) |
- |
15000 |
|
- |
5 Table 1(viii) Pitch of grill gate rods) |
- |
15000 |
|
- |
5 Table 1(vii) Diameter of grill gate rods, Min) |
- |
15000 |
|
- |
5 Table 1(vi) Thickens of grill gate angles or
section made out of M.S. plates, Min) |
- |
15000 |
|
- |
5 Table 1(v) Dimension of the rebate coming under shear) |
- |
15000 |
|
- |
5 Table 1(iv (b) Thickness of door frame, if
fabricated from single plate to form
channel/multi-bend section, Min) |
- |
15000 |
|
- |
5 Table 1(ii (a) Height H, Min b) Width W, Min
iv(a) Thickness of door frame angle,
channel or section made out of M.S.
plates, if built up to form a channel,Min) |
- |
15000 |
|
- |
5 Table 1(iii) Inside dimension or clear opening when
door shutters are swung open at 180 degree) |
- |
15000 |
|
- |
5 Table 1(ii (b) Width W) |
- |
15000 |
|
- |
5 Table 1(ii (a) Height, H) |
- |
15000 |
|
- |
5 Table 1(ii) Overall dimension of vault door) |
- |
15000 |
|
- |
5 Table 1(i) Door Type) |
- |
15000 |
|
- |
4(Type) |
- |
15000 |
|
- |
5(Table-1)(Type of Door) |
- |
15000 |
|
- |
5(Table-1)(Overall dimesion of door) |
- |
15000 |
|
- |
5(Table-1)(Inside dimension or clear opening of door) |
- |
15000 |
|
- |
5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
15000 |
|
- |
5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
15000 |
|
- |
5(Table-1)(Dimension of the rebate coming under share) |
- |
15000 |
|
- |
5(Table-1)(Thickness of grill gate angle/section) |
- |
15000 |
|
- |
5(Table-1)(Diameter of grill gate rod) |
- |
15000 |
|
- |
5(Table-1)(Pitch of grill gate rod) |
- |
15000 |
|
- |
5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
15000 |
|
- |
5(Table-1)(Thickness of the door over lock) |
- |
15000 |
|
- |
5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
15000 |
|
- |
5(Table-1)(Wall thickness) |
- |
15000 |
|
- |
5(Table-1)(Number of locks) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolys on hinge side) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolts on opposite) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolts at top) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolts at bottom) |
- |
15000 |
|
- |
5(Table-1)(Cross sectional area as per shooting bolt) |
- |
15000 |
|
- |
5(Table-1)(Depth engagement of shooting) |
- |
15000 |
|
- |
6(Materail) |
- |
15000 |
|
- |
7(Classification) |
- |
15000 |
|
- |
8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
8.1.1.1(Locking device (unpickable dual control lock)) |
- |
15000 |
|
- |
8.1.2(Main Door- Outer & inner plate thickness) |
- |
15000 |
|
- |
8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
15000 |
|
- |
8.2(Door frame (No.of barckets & Size for gripping)) |
- |
15000 |
|
- |
8.2.1(Rebate of the door frame) |
- |
15000 |
|
- |
8.2.2(Compression mechanism) |
- |
15000 |
|
- |
8.2.3(Crane hinge mechanism) |
- |
15000 |
|
- |
8.3(Lock case) |
- |
15000 |
|
- |
8.3.2(Bolt work) |
- |
15000 |
|
- |
8.3.2.2(Construction (of bolt work)) |
- |
15000 |
|
- |
8.3.2.3(Bearing piller) |
- |
15000 |
|
- |
8.4.1(Shooting bolt control (By lock)) |
- |
15000 |
|
- |
8.4.2(Test of key-Lock) |
- |
15000 |
|
- |
8.4.3(Lock fixing bolts) |
- |
15000 |
|
- |
8.4.4(Time lock) |
- |
15000 |
|
- |
8.4.5(Automatic Relocking devise) |
- |
15000 |
|
- |
9 &9.1(Hinges) |
- |
15000 |
|
- |
9.1.1(Adjusting bolt) |
- |
15000 |
|
- |
9.2(Handles) |
- |
15000 |
|
- |
9.3(Foot bringe) |
- |
15000 |
|
- |
9.4(Vault lighting control) |
- |
15000 |
|
- |
10 &10.1(Dents,Burrs & Edges) |
- |
15000 |
|
- |
10.2(Colour coating thickness (Surafce paint)) |
- |
15000 |
|
- |
10.3(Cross Hatch test) |
- |
15000 |
|
- |
10.4(Door (Stainless cladding)) |
- |
15000 |
|
- |
11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
15000 |
|
- |
11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
15000 |
|
- |
12(Marking of door) |
- |
15000 |
|
- |
12.2(Marking on keys) |
- |
15000 |
|
- |
4(Type) |
- |
15000 |
|
- |
5(Table-1)(5(Table-1)) |
- |
15000 |
|
- |
5(Table-1)(Overall dimesion of door) |
- |
15000 |
|
- |
5(Table-1)(Inside dimension or clear opening of door) |
- |
15000 |
|
- |
5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
15000 |
|
- |
5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
15000 |
|
- |
5(Table-1)(Dimension of the rebate coming under share) |
- |
15000 |
|
- |
5(Table-1)(Thickness of grill gate angle/section) |
- |
15000 |
|
- |
5(Table-1)(Diameter of grill gate rod) |
- |
15000 |
|
- |
5(Table-1)(Pitch of grill gate rod) |
- |
15000 |
|
- |
5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
15000 |
|
- |
5(Table-1)(Thickness of the door over lock) |
- |
15000 |
|
- |
5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
15000 |
|
- |
5(Table-1)(Wall thickness) |
- |
15000 |
|
- |
5(Table-1)(Number of locks) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolys on hinge side) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolts at top) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolts at bottom) |
- |
15000 |
|
- |
5(Table-1)(Cross sectional area as per shooting bolt) |
- |
15000 |
|
- |
5(Table-1)(Depth engagement of shooting) |
- |
15000 |
|
- |
6(Materail) |
- |
15000 |
|
- |
7(Classification) |
- |
15000 |
|
- |
8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
8.1.1.1(Locking device (unpickable dual control lock)) |
- |
15000 |
|
- |
8.1.2(Main Door- Outer & inner plate thickness) |
- |
15000 |
|
- |
8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
15000 |
|
- |
8.2(Door frame (No.of barckets & Size for gripping)) |
- |
15000 |
|
- |
8.2.1(Rebate of the door frame) |
- |
15000 |
|
- |
8.2.2(Compression mechanism) |
- |
15000 |
|
- |
8.2.3(Crane hinge mechanism) |
- |
15000 |
|
- |
8.3(Lock case) |
- |
15000 |
|
- |
8.3.2(Bolt work) |
- |
15000 |
|
- |
8.3.2.2(Construction (of bolt work)) |
- |
15000 |
|
- |
8.3.2.3(Bearing piller) |
- |
15000 |
|
- |
8.4.1(Shooting bolt control (By lock)) |
- |
15000 |
|
- |
8.4.2(Test of key-Lock) |
- |
15000 |
|
- |
8.4.3(Lock fixing bolts) |
- |
15000 |
|
- |
8.4.4(Time lock) |
- |
15000 |
|
- |
8.4.5(Automatic Relocking devise) |
- |
15000 |
|
- |
9 &9.1(Hinges) |
- |
15000 |
|
- |
9.1.1(Adjusting bolt) |
- |
15000 |
|
- |
9.3(Foot bringe) |
- |
15000 |
|
- |
9.4(Vault lighting control) |
- |
15000 |
|
- |
10 &10.1(Dents,Burrs & Edges) |
- |
15000 |
|
- |
10.2(Colour coating thickness (Surafce paint)) |
- |
15000 |
|
- |
10.3(Cross Hatch test) |
- |
15000 |
|
- |
10.4(Door (Stainless cladding)) |
- |
15000 |
|
- |
11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
15000 |
|
- |
11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
15000 |
|
- |
12(Marking of door) |
- |
15000 |
|
- |
12.2(Marking on keys) |
- |
15000 |
|
- |
11.1 (3)(Fire and stream hose IS 11188 (Part 3)) |
- |
15000 |
|
- |
11.1 (2)(Fire endurance IS 11188 (Part 3)) |
- |
150000 |
|
- |
11.1 (1)(Burglary resistance IS 11188 (Part 2)) |
- |
150000 |
|
- |
10.4(Alternate to Cl 10.4) |
- |
15000 |
|
- |
10.3(Cross Hatch Test) |
- |
15000 |
|
- |
10(FINISH) |
- |
15000 |
|
- |
9.4(Vault Lighting Control) |
- |
15000 |
|
- |
9.3(Foot Bridge) |
- |
15000 |
|
- |
9.2(Handles) |
- |
15000 |
|
- |
9.1.1(Adjusting Bolt) |
- |
15000 |
|
- |
9.1(Hinges) |
- |
15000 |
|
- |
9(DOOR FITTINGS) |
- |
15000 |
|
- |
8.4.5(Automatic Relocking Device) |
- |
15000 |
|
- |
8.4.4(Time Lock) |
- |
15000 |
|
- |
8.4(Lock) |
- |
15000 |
|
- |
8.3.2.2(Construction) |
- |
15000 |
|
- |
8.3.2.1(The number of bolts and their minimum dimension) |
- |
15000 |
|
- |
8.3.2(Bolt Work) |
- |
15000 |
|
- |
8.3.1(Lock Case) |
- |
15000 |
|
- |
8.3(Locking Mechanism) |
- |
15000 |
|
- |
8.2.3(Crane Hinge Mechanism) |
- |
15000 |
|
- |
8.2.2(Compression Mechanism) |
- |
15000 |
|
- |
8.2.1(Rebate of the Door Frame) |
- |
15000 |
|
- |
8.2(Doors Frame) |
- |
15000 |
|
- |
8.1.2(Main Door (Outside)) |
- |
15000 |
|
- |
8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
8.1 Fig. 1(Doors) |
- |
15000 |
|
- |
8(CONSTRUCTION AND GENERALREQUIREMENTS) |
- |
15000 |
|
- |
5 Table 1(bolts, Min) |
- |
15000 |
|
- |
5 Table 1(xix) Depth of engagement of shooting) |
- |
15000 |
|
- |
5 Table 1(cross sectional area, Min,sq mm) |
- |
15000 |
|
- |
5 Table 1(xviii) Diameter of shooting bolts, Min) |
- |
15000 |
|
- |
5 Table 1(xvi) Number of shooting bolts at top,Min) |
- |
15000 |
|
- |
5 Table 1(xv) Number of shooting bolts on opposite side,Min) |
- |
15000 |
|
- |
5 Table 1(xiv) Number of shooting bolts on hinge side, Min) |
- |
15000 |
|
- |
5 Table 1(xiii) Number of locks) |
- |
15000 |
|
- |
5 Table 1(xii) Wall thickness (recommendation)) |
- |
15000 |
|
- |
5 Table 1(xi) Thickness of drill and oxyacetylene
torch resisting layer (excluding mild steel plates),Min) |
- |
15000 |
|
- |
5 Table 1(ix) Thickness of doors slab, thickness over rebate) |
- |
15000 |
|
- |
5 Table 1(viii) Pitch of grill gate rods) |
- |
15000 |
|
- |
5 Table 1(vii) Diameter of grill gate rods, Min) |
- |
15000 |
|
- |
5 Table 1(vi) Thickens of grill gate angles or
section made out of M.S. plates, Min) |
- |
15000 |
|
- |
5 Table 1(v) Dimension of the rebate coming under shear) |
- |
15000 |
|
- |
5 Table 1(iv (b) Thickness of door frame, if
fabricated from single plate to form
channel/multi-bend section, Min) |
- |
15000 |
|
- |
5 Table 1(ii (a) Height H, Min b) Width W, Min
iv(a) Thickness of door frame angle,
channel or section made out of M.S.
plates, if built up to form a channel,Min) |
- |
15000 |
|
- |
5 Table 1(iii) Inside dimension or clear opening when
door shutters are swung open at 180 degree) |
- |
15000 |
|
- |
5 Table 1(ii (b) Width W) |
- |
15000 |
|
- |
5 Table 1(ii (a) Height, H) |
- |
15000 |
|
- |
5 Table 1(ii) Overall dimension of vault door) |
- |
15000 |
|
- |
5 Table 1(i) Door Type) |
- |
15000 |
|
- |
4(Type) |
- |
15000 |
|
- |
5(Table-1)(Type of Door) |
- |
15000 |
|
- |
5(Table-1)(Overall dimesion of door) |
- |
15000 |
|
- |
5(Table-1)(Inside dimension or clear opening of door) |
- |
15000 |
|
- |
5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
15000 |
|
- |
5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
15000 |
|
- |
5(Table-1)(Dimension of the rebate coming under share) |
- |
15000 |
|
- |
5(Table-1)(Thickness of grill gate angle/section) |
- |
15000 |
|
- |
5(Table-1)(Diameter of grill gate rod) |
- |
15000 |
|
- |
5(Table-1)(Pitch of grill gate rod) |
- |
15000 |
|
- |
5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
15000 |
|
- |
5(Table-1)(Thickness of the door over lock) |
- |
15000 |
|
- |
5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
15000 |
|
- |
5(Table-1)(Wall thickness) |
- |
15000 |
|
- |
5(Table-1)(Number of locks) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolys on hinge side) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolts on opposite) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolts at top) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolts at bottom) |
- |
15000 |
|
- |
5(Table-1)(Cross sectional area as per shooting bolt) |
- |
15000 |
|
- |
5(Table-1)(Depth engagement of shooting) |
- |
15000 |
|
- |
6(Materail) |
- |
15000 |
|
- |
7(Classification) |
- |
15000 |
|
- |
8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
8.1.1.1(Locking device (unpickable dual control lock)) |
- |
15000 |
|
- |
8.1.2(Main Door- Outer & inner plate thickness) |
- |
15000 |
|
- |
8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
15000 |
|
- |
8.2(Door frame (No.of barckets & Size for gripping)) |
- |
15000 |
|
- |
8.2.1(Rebate of the door frame) |
- |
15000 |
|
- |
8.2.2(Compression mechanism) |
- |
15000 |
|
- |
8.2.3(Crane hinge mechanism) |
- |
15000 |
|
- |
8.3(Lock case) |
- |
15000 |
|
- |
8.3.2(Bolt work) |
- |
15000 |
|
- |
8.3.2.2(Construction (of bolt work)) |
- |
15000 |
|
- |
8.3.2.3(Bearing piller) |
- |
15000 |
|
- |
8.4.1(Shooting bolt control (By lock)) |
- |
15000 |
|
- |
8.4.2(Test of key-Lock) |
- |
15000 |
|
- |
8.4.3(Lock fixing bolts) |
- |
15000 |
|
- |
8.4.4(Time lock) |
- |
15000 |
|
- |
8.4.5(Automatic Relocking devise) |
- |
15000 |
|
- |
9 &9.1(Hinges) |
- |
15000 |
|
- |
9.1.1(Adjusting bolt) |
- |
15000 |
|
- |
9.2(Handles) |
- |
15000 |
|
- |
9.3(Foot bringe) |
- |
15000 |
|
- |
9.4(Vault lighting control) |
- |
15000 |
|
- |
10 &10.1(Dents,Burrs & Edges) |
- |
15000 |
|
- |
10.2(Colour coating thickness (Surafce paint)) |
- |
15000 |
|
- |
10.3(Cross Hatch test) |
- |
15000 |
|
- |
10.4(Door (Stainless cladding)) |
- |
15000 |
|
- |
11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
15000 |
|
- |
11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
15000 |
|
- |
12(Marking of door) |
- |
15000 |
|
- |
12.2(Marking on keys) |
- |
15000 |
|
- |
4(Type) |
- |
15000 |
|
- |
5(Table-1)(5(Table-1)) |
- |
15000 |
|
- |
5(Table-1)(Overall dimesion of door) |
- |
15000 |
|
- |
5(Table-1)(Inside dimension or clear opening of door) |
- |
15000 |
|
- |
5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
15000 |
|
- |
5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
15000 |
|
- |
5(Table-1)(Dimension of the rebate coming under share) |
- |
15000 |
|
- |
5(Table-1)(Thickness of grill gate angle/section) |
- |
15000 |
|
- |
5(Table-1)(Diameter of grill gate rod) |
- |
15000 |
|
- |
5(Table-1)(Pitch of grill gate rod) |
- |
15000 |
|
- |
5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
15000 |
|
- |
5(Table-1)(Thickness of the door over lock) |
- |
15000 |
|
- |
5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
15000 |
|
- |
5(Table-1)(Wall thickness) |
- |
15000 |
|
- |
5(Table-1)(Number of locks) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolys on hinge side) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolts at top) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolts at bottom) |
- |
15000 |
|
- |
5(Table-1)(Cross sectional area as per shooting bolt) |
- |
15000 |
|
- |
5(Table-1)(Depth engagement of shooting) |
- |
15000 |
|
- |
6(Materail) |
- |
15000 |
|
- |
7(Classification) |
- |
15000 |
|
- |
8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
8.1.1.1(Locking device (unpickable dual control lock)) |
- |
15000 |
|
- |
8.1.2(Main Door- Outer & inner plate thickness) |
- |
15000 |
|
- |
8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
15000 |
|
- |
8.2(Door frame (No.of barckets & Size for gripping)) |
- |
15000 |
|
- |
8.2.1(Rebate of the door frame) |
- |
15000 |
|
- |
8.2.2(Compression mechanism) |
- |
15000 |
|
- |
8.2.3(Crane hinge mechanism) |
- |
15000 |
|
- |
8.3(Lock case) |
- |
15000 |
|
- |
8.3.2(Bolt work) |
- |
15000 |
|
- |
8.3.2.2(Construction (of bolt work)) |
- |
15000 |
|
- |
8.3.2.3(Bearing piller) |
- |
15000 |
|
- |
8.4.1(Shooting bolt control (By lock)) |
- |
15000 |
|
- |
8.4.2(Test of key-Lock) |
- |
15000 |
|
- |
8.4.3(Lock fixing bolts) |
- |
15000 |
|
- |
8.4.4(Time lock) |
- |
15000 |
|
- |
8.4.5(Automatic Relocking devise) |
- |
15000 |
|
- |
9 &9.1(Hinges) |
- |
15000 |
|
- |
9.1.1(Adjusting bolt) |
- |
15000 |
|
- |
9.3(Foot bringe) |
- |
15000 |
|
- |
9.4(Vault lighting control) |
- |
15000 |
|
- |
10 &10.1(Dents,Burrs & Edges) |
- |
15000 |
|
- |
10.2(Colour coating thickness (Surafce paint)) |
- |
15000 |
|
- |
10.3(Cross Hatch test) |
- |
15000 |
|
- |
10.4(Door (Stainless cladding)) |
- |
15000 |
|
- |
11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
15000 |
|
- |
11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
15000 |
|
- |
12(Marking of door) |
- |
5000 |
|
- |
12.2(Marking on keys) |
- |
5000 |
|
- |
11.1 (3)(Fire and stream hose IS 11188 (Part 3)) |
- |
15000 |
|
- |
11.1 (2)(Fire endurance IS 11188 (Part 3)) |
- |
150000 |
|
- |
11.1 (1)(Burglary resistance IS 11188 (Part 2)) |
- |
150000 |
|
- |
10.4(Alternate to Cl 10.4) |
- |
15000 |
|
- |
10.3(Cross Hatch Test) |
- |
15000 |
|
- |
10(FINISH) |
- |
15000 |
|
- |
9.4(Vault Lighting Control) |
- |
15000 |
|
- |
9.3(Foot Bridge) |
- |
15000 |
|
- |
9.2(Handles) |
- |
15000 |
|
- |
9.1.1(Adjusting Bolt) |
- |
15000 |
|
- |
9.1(Hinges) |
- |
15000 |
|
- |
9(DOOR FITTINGS) |
- |
15000 |
|
- |
8.4.5(Automatic Relocking Device) |
- |
15000 |
|
- |
8.4.4(Time Lock) |
- |
15000 |
|
- |
8.4(Lock) |
- |
15000 |
|
- |
8.3.2.2(Construction) |
- |
15000 |
|
- |
8.3.2.1(The number of bolts and their minimum dimension) |
- |
15000 |
|
- |
8.3.2(Bolt Work) |
- |
15000 |
|
- |
8.3.1(Lock Case) |
- |
15000 |
|
- |
8.3(Locking Mechanism) |
- |
15000 |
|
- |
8.2.3(Crane Hinge Mechanism) |
- |
15000 |
|
- |
8.2.2(Compression Mechanism) |
- |
15000 |
|
- |
8.2.1(Rebate of the Door Frame) |
- |
15000 |
|
- |
8.2(Doors Frame) |
- |
15000 |
|
- |
8.1.2(Main Door (Outside)) |
- |
15000 |
|
- |
8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
8.1 Fig. 1(Doors) |
- |
15000 |
|
- |
8(CONSTRUCTION AND GENERALREQUIREMENTS) |
- |
15000 |
|
- |
5 Table 1(bolts, Min) |
- |
15000 |
|
- |
5 Table 1(xix) Depth of engagement of shooting) |
- |
15000 |
|
- |
5 Table 1(cross sectional area, Min,sq mm) |
- |
15000 |
|
- |
5 Table 1(xviii) Diameter of shooting bolts, Min) |
- |
15000 |
|
- |
5 Table 1(xvi) Number of shooting bolts at top,Min) |
- |
15000 |
|
- |
5 Table 1(xv) Number of shooting bolts on opposite side,Min) |
- |
15000 |
|
- |
5 Table 1(xiv) Number of shooting bolts on hinge side, Min) |
- |
15000 |
|
- |
5 Table 1(xiii) Number of locks) |
- |
15000 |
|
- |
5 Table 1(xii) Wall thickness (recommendation)) |
- |
15000 |
|
- |
5 Table 1(xi) Thickness of drill and oxyacetylene
torch resisting layer (excluding mild steel plates),Min) |
- |
15000 |
|
- |
5 Table 1(ix) Thickness of doors slab, thickness over rebate) |
- |
15000 |
|
- |
5 Table 1(viii) Pitch of grill gate rods) |
- |
15000 |
|
- |
5 Table 1(vii) Diameter of grill gate rods, Min) |
- |
15000 |
|
- |
5 Table 1(vi) Thickens of grill gate angles or
section made out of M.S. plates, Min) |
- |
15000 |
|
- |
5 Table 1(v) Dimension of the rebate coming under shear) |
- |
15000 |
|
- |
5 Table 1(iv (b) Thickness of door frame, if
fabricated from single plate to form
channel/multi-bend section, Min) |
- |
15000 |
|
- |
5 Table 1(ii (a) Height H, Min b) Width W, Min
iv(a) Thickness of door frame angle,
channel or section made out of M.S.
plates, if built up to form a channel,Min) |
- |
15000 |
|
- |
5 Table 1(iii) Inside dimension or clear opening when
door shutters are swung open at 180 degree) |
- |
15000 |
|
- |
5 Table 1(ii (b) Width W) |
- |
15000 |
|
- |
5 Table 1(ii (a) Height, H) |
- |
15000 |
|
- |
5 Table 1(ii) Overall dimension of vault door) |
- |
15000 |
|
- |
5 Table 1(i) Door Type) |
- |
15000 |
|
- |
4(Type) |
- |
15000 |
|
- |
5(Table-1)(Type of Door) |
- |
15000 |
|
- |
5(Table-1)(Overall dimesion of door) |
- |
15000 |
|
- |
5(Table-1)(Inside dimension or clear opening of door) |
- |
15000 |
|
- |
5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
15000 |
|
- |
5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
15000 |
|
- |
5(Table-1)(Dimension of the rebate coming under share) |
- |
15000 |
|
- |
5(Table-1)(Thickness of grill gate angle/section) |
- |
15000 |
|
- |
5(Table-1)(Diameter of grill gate rod) |
- |
15000 |
|
- |
5(Table-1)(Pitch of grill gate rod) |
- |
15000 |
|
- |
5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
15000 |
|
- |
5(Table-1)(Thickness of the door over lock) |
- |
15000 |
|
- |
5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
15000 |
|
- |
5(Table-1)(Wall thickness) |
- |
15000 |
|
- |
5(Table-1)(Number of locks) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolys on hinge side) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolts on opposite) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolts at top) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolts at bottom) |
- |
15000 |
|
- |
5(Table-1)(Cross sectional area as per shooting bolt) |
- |
15000 |
|
- |
5(Table-1)(Depth engagement of shooting) |
- |
15000 |
|
- |
6(Materail) |
- |
15000 |
|
- |
7(Classification) |
- |
15000 |
|
- |
8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
8.1.1.1(Locking device (unpickable dual control lock)) |
- |
15000 |
|
- |
8.1.2(Main Door- Outer & inner plate thickness) |
- |
15000 |
|
- |
8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
15000 |
|
- |
8.2(Door frame (No.of barckets & Size for gripping)) |
- |
15000 |
|
- |
8.2.1(Rebate of the door frame) |
- |
15000 |
|
- |
8.2.2(Compression mechanism) |
- |
15000 |
|
- |
8.2.3(Crane hinge mechanism) |
- |
15000 |
|
- |
8.3(Lock case) |
- |
15000 |
|
- |
8.3.2(Bolt work) |
- |
15000 |
|
- |
8.3.2.2(Construction (of bolt work)) |
- |
15000 |
|
- |
8.3.2.3(Bearing piller) |
- |
15000 |
|
- |
8.4.1(Shooting bolt control (By lock)) |
- |
15000 |
|
- |
8.4.2(Test of key-Lock) |
- |
15000 |
|
- |
8.4.3(Lock fixing bolts) |
- |
15000 |
|
- |
8.4.4(Time lock) |
- |
15000 |
|
- |
8.4.5(Automatic Relocking devise) |
- |
15000 |
|
- |
9 &9.1(Hinges) |
- |
15000 |
|
- |
9.1.1(Adjusting bolt) |
- |
15000 |
|
- |
9.2(Handles) |
- |
15000 |
|
- |
9.3(Foot bringe) |
- |
15000 |
|
- |
9.4(Vault lighting control) |
- |
15000 |
|
- |
10 &10.1(Dents,Burrs & Edges) |
- |
15000 |
|
- |
10.2(Colour coating thickness (Surafce paint)) |
- |
15000 |
|
- |
10.3(Cross Hatch test) |
- |
15000 |
|
- |
10.4(Door (Stainless cladding)) |
- |
15000 |
|
- |
11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
15000 |
|
- |
11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
15000 |
|
- |
12(Marking of door) |
- |
15000 |
|
- |
12.2(Marking on keys) |
- |
15000 |
|
- |
4(Type) |
- |
15000 |
|
- |
5(Table-1)(5(Table-1)) |
- |
15000 |
|
- |
5(Table-1)(Overall dimesion of door) |
- |
15000 |
|
- |
5(Table-1)(Inside dimension or clear opening of door) |
- |
15000 |
|
- |
5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
15000 |
|
- |
5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
15000 |
|
- |
5(Table-1)(Dimension of the rebate coming under share) |
- |
15000 |
|
- |
5(Table-1)(Thickness of grill gate angle/section) |
- |
15000 |
|
- |
5(Table-1)(Diameter of grill gate rod) |
- |
15000 |
|
- |
5(Table-1)(Pitch of grill gate rod) |
- |
15000 |
|
- |
5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
15000 |
|
- |
5(Table-1)(Thickness of the door over lock) |
- |
15000 |
|
- |
5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
15000 |
|
- |
5(Table-1)(Wall thickness) |
- |
15000 |
|
- |
5(Table-1)(Number of locks) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolys on hinge side) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolts at top) |
- |
15000 |
|
- |
5(Table-1)(Number of shooting bolts at bottom) |
- |
15000 |
|
- |
5(Table-1)(Cross sectional area as per shooting bolt) |
- |
15000 |
|
- |
5(Table-1)(Depth engagement of shooting) |
- |
15000 |
|
- |
6(Materail) |
- |
15000 |
|
- |
7(Classification) |
- |
15000 |
|
- |
8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
8.1.1.1(Locking device (unpickable dual control lock)) |
- |
15000 |
|
- |
8.1.2(Main Door- Outer & inner plate thickness) |
- |
15000 |
|
- |
8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
15000 |
|
- |
8.2(Door frame (No.of barckets & Size for gripping)) |
- |
15000 |
|
- |
8.2.1(Rebate of the door frame) |
- |
15000 |
|
- |
8.2.2(Compression mechanism) |
- |
15000 |
|
- |
8.2.3(Crane hinge mechanism) |
- |
15000 |
|
- |
8.3(Lock case) |
- |
15000 |
|
- |
8.3.2(Bolt work) |
- |
15000 |
|
- |
8.3.2.2(Construction (of bolt work)) |
- |
15000 |
|
- |
8.3.2.3(Bearing piller) |
- |
15000 |
|
- |
8.4.1(Shooting bolt control (By lock)) |
- |
15000 |
|
- |
8.4.2(Test of key-Lock) |
- |
15000 |
|
- |
8.4.3(Lock fixing bolts) |
- |
15000 |
|
- |
8.4.4(Time lock) |
- |
15000 |
|
- |
8.4.5(Automatic Relocking devise) |
- |
15000 |
|
- |
9 &9.1(Hinges) |
- |
15000 |
|
- |
9.1.1(Adjusting bolt) |
- |
15000 |
|
- |
9.3(Foot bringe) |
- |
15000 |
|
- |
9.4(Vault lighting control) |
- |
15000 |
|
- |
10 &10.1(Dents,Burrs & Edges) |
- |
15000 |
|
- |
10.2(Colour coating thickness (Surafce paint)) |
- |
15000 |
|
- |
10.3(Cross Hatch test) |
- |
15000 |
|
- |
10.4(Door (Stainless cladding)) |
- |
15000 |
|
- |
11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
15000 |
|
- |
11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
15000 |
|
- |
12(Marking of door) |
- |
15000 |
|
- |
12.2(Marking on keys) |
- |
15000 |
|
- |
|
Complete
|
|
14 Nov, 2027 |
- Included w.e.f. 28.03.2025 |
624 |
Atmy Analytical Labs Private Limited (Unit-2)
| IS 11188 : Part 1 (2021) |
Vault Strong Room doors Part 1 specification |
ALL |
-
|
349000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
11.1 (3)(Fire and stream hose IS 11188 (Part 3)) |
- |
349000 |
|
- |
11.1 (2)(Fire endurance IS 11188 (Part 3)) |
- |
349000 |
|
- |
11.1 (1)(Burglary resistance IS 11188 (Part 2)) |
- |
349000 |
|
- |
10.4(Alternate to Cl 10.4) |
- |
349000 |
|
- |
10.3(Cross Hatch Test) |
- |
349000 |
|
- |
10(FINISH) |
- |
349000 |
|
- |
9.4(Vault Lighting Control) |
- |
349000 |
|
- |
9.3(Foot Bridge) |
- |
349000 |
|
- |
9.2(Handles) |
- |
349000 |
|
- |
9.1.1(Adjusting Bolt) |
- |
349000 |
|
- |
9.1(Hinges) |
- |
349000 |
|
- |
9(DOOR FITTINGS) |
- |
349000 |
|
- |
8.4.5(Automatic Relocking Device) |
- |
349000 |
|
- |
8.4.4(Time Lock) |
- |
349000 |
|
- |
8.4(Lock) |
- |
349000 |
|
- |
8.3.2.2(Construction) |
- |
349000 |
|
- |
8.3.2.1(The number of bolts and their minimum dimension) |
- |
349000 |
|
- |
8.3.2(Bolt Work) |
- |
349000 |
|
- |
8.3.1(Lock Case) |
- |
349000 |
|
- |
8.3(Locking Mechanism) |
- |
349000 |
|
- |
8.2.3(Crane Hinge Mechanism) |
- |
349000 |
|
- |
8.2.2(Compression Mechanism) |
- |
349000 |
|
- |
8.2.1(Rebate of the Door Frame) |
- |
349000 |
|
- |
8.2(Doors Frame) |
- |
349000 |
|
- |
8.1.2(Main Door (Outside)) |
- |
349000 |
|
- |
8.1.1(Ventilating Grill Gate (Inside)) |
- |
349000 |
|
- |
8.1 Fig. 1(Doors) |
- |
349000 |
|
- |
8(CONSTRUCTION AND GENERALREQUIREMENTS) |
- |
349000 |
|
- |
5 Table 1(bolts, Min) |
- |
349000 |
|
- |
5 Table 1(xix) Depth of engagement of shooting) |
- |
349000 |
|
- |
5 Table 1(cross sectional area, Min,sq mm) |
- |
349000 |
|
- |
5 Table 1(xviii) Diameter of shooting bolts, Min) |
- |
349000 |
|
- |
5 Table 1(xvi) Number of shooting bolts at top,Min) |
- |
349000 |
|
- |
5 Table 1(xv) Number of shooting bolts on opposite side,Min) |
- |
349000 |
|
- |
5 Table 1(xiv) Number of shooting bolts on hinge side, Min) |
- |
349000 |
|
- |
5 Table 1(xiii) Number of locks) |
- |
349000 |
|
- |
5 Table 1(xii) Wall thickness (recommendation)) |
- |
349000 |
|
- |
5 Table 1(xi) Thickness of drill and oxyacetylene
torch resisting layer (excluding mild steel plates),Min) |
- |
349000 |
|
- |
5 Table 1(ix) Thickness of doors slab, thickness over rebate) |
- |
349000 |
|
- |
5 Table 1(viii) Pitch of grill gate rods) |
- |
349000 |
|
- |
5 Table 1(vii) Diameter of grill gate rods, Min) |
- |
349000 |
|
- |
5 Table 1(vi) Thickens of grill gate angles or
section made out of M.S. plates, Min) |
- |
349000 |
|
- |
5 Table 1(v) Dimension of the rebate coming under shear) |
- |
349000 |
|
- |
5 Table 1(iv (b) Thickness of door frame, if
fabricated from single plate to form
channel/multi-bend section, Min) |
- |
349000 |
|
- |
5 Table 1(ii (a) Height H, Min b) Width W, Min
iv(a) Thickness of door frame angle,
channel or section made out of M.S.
plates, if built up to form a channel,Min) |
- |
349000 |
|
- |
5 Table 1(iii) Inside dimension or clear opening when
door shutters are swung open at 180 degree) |
- |
349000 |
|
- |
5 Table 1(ii (b) Width W) |
- |
349000 |
|
- |
5 Table 1(ii (a) Height, H) |
- |
349000 |
|
- |
5 Table 1(ii) Overall dimension of vault door) |
- |
349000 |
|
- |
5 Table 1(i) Door Type) |
- |
349000 |
|
- |
4(Type) |
- |
349000 |
|
- |
5(Table-1)(Type of Door) |
- |
349000 |
|
- |
5(Table-1)(Overall dimesion of door) |
- |
349000 |
|
- |
5(Table-1)(Inside dimension or clear opening of door) |
- |
349000 |
|
- |
5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
349000 |
|
- |
5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
349000 |
|
- |
5(Table-1)(Dimension of the rebate coming under share) |
- |
349000 |
|
- |
5(Table-1)(Thickness of grill gate angle/section) |
- |
349000 |
|
- |
5(Table-1)(Diameter of grill gate rod) |
- |
349000 |
|
- |
5(Table-1)(Pitch of grill gate rod) |
- |
349000 |
|
- |
5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
349000 |
|
- |
5(Table-1)(Thickness of the door over lock) |
- |
349000 |
|
- |
5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
349000 |
|
- |
5(Table-1)(Wall thickness) |
- |
349000 |
|
- |
5(Table-1)(Number of locks) |
- |
349000 |
|
- |
5(Table-1)(Number of shooting bolys on hinge side) |
- |
349000 |
|
- |
5(Table-1)(Number of shooting bolts on opposite) |
- |
349000 |
|
- |
5(Table-1)(Number of shooting bolts at top) |
- |
349000 |
|
- |
5(Table-1)(Number of shooting bolts at bottom) |
- |
349000 |
|
- |
5(Table-1)(Cross sectional area as per shooting bolt) |
- |
349000 |
|
- |
5(Table-1)(Depth engagement of shooting) |
- |
349000 |
|
- |
6(Materail) |
- |
349000 |
|
- |
7(Classification) |
- |
349000 |
|
- |
8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
349000 |
|
- |
8.1.1.1(Locking device (unpickable dual control lock)) |
- |
349000 |
|
- |
8.1.2(Main Door- Outer & inner plate thickness) |
- |
349000 |
|
- |
8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
349000 |
|
- |
8.2(Door frame (No.of barckets & Size for gripping)) |
- |
349000 |
|
- |
8.2.1(Rebate of the door frame) |
- |
349000 |
|
- |
8.2.2(Compression mechanism) |
- |
349000 |
|
- |
8.2.3(Crane hinge mechanism) |
- |
349000 |
|
- |
8.3(Lock case) |
- |
349000 |
|
- |
8.3.2(Bolt work) |
- |
349000 |
|
- |
8.3.2.2(Construction (of bolt work)) |
- |
349000 |
|
- |
8.3.2.3(Bearing piller) |
- |
349000 |
|
- |
8.4.1(Shooting bolt control (By lock)) |
- |
349000 |
|
- |
8.4.2(Test of key-Lock) |
- |
349000 |
|
- |
8.4.3(Lock fixing bolts) |
- |
349000 |
|
- |
8.4.4(Time lock) |
- |
349000 |
|
- |
8.4.5(Automatic Relocking devise) |
- |
349000 |
|
- |
9 &9.1(Hinges) |
- |
349000 |
|
- |
9.1.1(Adjusting bolt) |
- |
349000 |
|
- |
9.2(Handles) |
- |
349000 |
|
- |
9.3(Foot bringe) |
- |
349000 |
|
- |
9.4(Vault lighting control) |
- |
349000 |
|
- |
10 &10.1(Dents,Burrs & Edges) |
- |
349000 |
|
- |
10.2(Colour coating thickness (Surafce paint)) |
- |
349000 |
|
- |
10.3(Cross Hatch test) |
- |
349000 |
|
- |
10.4(Door (Stainless cladding)) |
- |
349000 |
|
- |
11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
349000 |
|
- |
11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
349000 |
|
- |
12(Marking of door) |
- |
349000 |
|
- |
12.2(Marking on keys) |
- |
349000 |
|
- |
4(Type) |
- |
349000 |
|
- |
5(Table-1)(5(Table-1)) |
- |
349000 |
|
- |
5(Table-1)(Overall dimesion of door) |
- |
349000 |
|
- |
5(Table-1)(Inside dimension or clear opening of door) |
- |
349000 |
|
- |
5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
349000 |
|
- |
5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
349000 |
|
- |
5(Table-1)(Dimension of the rebate coming under share) |
- |
349000 |
|
- |
5(Table-1)(Thickness of grill gate angle/section) |
- |
349000 |
|
- |
5(Table-1)(Diameter of grill gate rod) |
- |
349000 |
|
- |
5(Table-1)(Pitch of grill gate rod) |
- |
349000 |
|
- |
5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
349000 |
|
- |
5(Table-1)(Thickness of the door over lock) |
- |
349000 |
|
- |
5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
349000 |
|
- |
5(Table-1)(Wall thickness) |
- |
349000 |
|
- |
5(Table-1)(Number of locks) |
- |
349000 |
|
- |
5(Table-1)(Number of shooting bolys on hinge side) |
- |
349000 |
|
- |
5(Table-1)(Number of shooting bolts at top) |
- |
349000 |
|
- |
5(Table-1)(Number of shooting bolts at bottom) |
- |
349000 |
|
- |
5(Table-1)(Cross sectional area as per shooting bolt) |
- |
349000 |
|
- |
5(Table-1)(Depth engagement of shooting) |
- |
349000 |
|
- |
6(Materail) |
- |
349000 |
|
- |
7(Classification) |
- |
349000 |
|
- |
8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
349000 |
|
- |
8.1.1.1(Locking device (unpickable dual control lock)) |
- |
349000 |
|
- |
8.1.2(Main Door- Outer & inner plate thickness) |
- |
349000 |
|
- |
8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
349000 |
|
- |
8.2(Door frame (No.of barckets & Size for gripping)) |
- |
349000 |
|
- |
8.2.1(Rebate of the door frame) |
- |
349000 |
|
- |
8.2.2(Compression mechanism) |
- |
349000 |
|
- |
8.2.3(Crane hinge mechanism) |
- |
349000 |
|
- |
8.3(Lock case) |
- |
349000 |
|
- |
8.3.2(Bolt work) |
- |
349000 |
|
- |
8.3.2.2(Construction (of bolt work)) |
- |
349000 |
|
- |
8.3.2.3(Bearing piller) |
- |
349000 |
|
- |
8.4.1(Shooting bolt control (By lock)) |
- |
349000 |
|
- |
8.4.2(Test of key-Lock) |
- |
349000 |
|
- |
8.4.3(Lock fixing bolts) |
- |
349000 |
|
- |
8.4.4(Time lock) |
- |
349000 |
|
- |
8.4.5(Automatic Relocking devise) |
- |
349000 |
|
- |
9 &9.1(Hinges) |
- |
349000 |
|
- |
9.1.1(Adjusting bolt) |
- |
349000 |
|
- |
9.3(Foot bringe) |
- |
349000 |
|
- |
9.4(Vault lighting control) |
- |
349000 |
|
- |
10 &10.1(Dents,Burrs & Edges) |
- |
349000 |
|
- |
10.2(Colour coating thickness (Surafce paint)) |
- |
349000 |
|
- |
10.3(Cross Hatch test) |
- |
349000 |
|
- |
10.4(Door (Stainless cladding)) |
- |
349000 |
|
- |
11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
349000 |
|
- |
11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
349000 |
|
- |
12(Marking of door) |
- |
349000 |
|
- |
12.2(Marking on keys) |
- |
349000 |
|
- |
|
Complete
|
|
08 Feb, 2027 |
- Included w.e.f. 01.04.2025 |
625 |
Atmy Analytical Labs Private Limited (Unit-2)
| IS 5244 (2020) |
Safe Deposit Locker Cabinets — Specification ( Fourth Revision ) |
- |
-
|
39500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 4.1( Types ) |
- |
0 |
|
- |
Cl. 6 (Fig-5)(Cabinet Size (in mm)) |
- |
0 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
Table 1(Finish) |
- |
0 |
|
- |
Table 1(Finish) |
- |
0 |
|
- |
Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
0 |
|
- |
Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
0 |
|
- |
Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
0 |
|
- |
Cl. 7.1(Design and Manufacture) |
- |
0 |
|
- |
Cl. 7.1(Design and Manufacture) |
- |
0 |
|
- |
Cl. 7.1(Design and Manufacture) |
- |
0 |
|
- |
Cl. 7.1(Design and Manufacture) |
- |
0 |
|
- |
Cl. 7.1(Design and Manufacture) |
- |
0 |
|
- |
Cl. 7.2(Design and Manufacture) |
- |
0 |
|
- |
Cl. 7.3(Design and Manufacture) |
- |
0 |
|
- |
Cl. 7.3(Design and Manufacture) |
- |
0 |
|
- |
Cl. 7.4(Design and Manufacture) |
- |
0 |
|
- |
Cl. 7.5(Design and Manufacture) |
- |
0 |
|
- |
Cl. 7.6(Design and Manufacture) |
- |
0 |
|
- |
Cl. 8(Workmanship) |
- |
0 |
|
- |
Cl. 8.2(Tolerance) |
- |
0 |
|
- |
Cl. 9.1(Testing) |
- |
0 |
|
- |
Cl. 9.2(Testing) |
- |
0 |
|
- |
Cl. 9.3(Cross Hatch Test) |
- |
0 |
|
- |
Cl. 10.1(Marking) |
- |
0 |
|
- |
Cl. 10.2(Marking) |
- |
0 |
|
- |
Cl. 10.3(Marking) |
- |
0 |
|
- |
Cl. 10.4(Marking on Keys) |
- |
0 |
|
- |
Cl. 11(Packing) |
- |
0 |
|
- |
|
Complete
|
|
08 Feb, 2027 |
- Included w.e.f. 01.04.2025 |
626 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 2347 (2017) |
Domestic pressure cooker - Specification (Sixth Revision) |
- |
-
|
34000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(Capacity) |
- |
400 |
|
- |
5.1.1(Body, Lid, Containers and Grid) |
- |
300 |
|
- |
5.1.2(Body, Lid, Containers and Grid) |
- |
300 |
|
- |
5.1.3(Body, Lid, Containers and Grid) |
- |
300 |
|
- |
5.1.4(Body, Lid, Containers and Grid) |
- |
300 |
|
- |
5.2(Safety Relief Device) |
- |
300 |
|
- |
5.3(Gasket) |
- |
300 |
|
- |
5.4(Handles and Knobs) |
- |
300 |
|
- |
5.5(Pressure Regulating Device) |
- |
300 |
|
- |
5.6(Vent Seal Pin for Pressure Regulating Device) |
- |
300 |
|
- |
5.7(Vent Pipe) |
- |
300 |
|
- |
5.8(Vent Pipe Nut) |
- |
300 |
|
- |
5.9(Spring) |
- |
300 |
|
- |
6(CONSTRUCTION) |
- |
300 |
|
- |
6.1(Pressure Regulating Device) |
- |
300 |
|
- |
6.1.1(Pressure Regulating Device) |
- |
300 |
|
- |
6.1.2(Pressure Regulating Device) |
- |
300 |
|
- |
6.1.3(Pressure Regulating Device) |
- |
300 |
|
- |
6.1.4(Pressure Regulating Device) |
- |
300 |
|
- |
6.1.5(Pressure Regulating Device) |
- |
300 |
|
- |
6.2(Safety Relief Device) |
- |
300 |
|
- |
6.2.1(Safety Relief Device) |
- |
300 |
|
- |
6.2.2(Safety Relief Device) |
- |
300 |
|
- |
6.3.1(Temperature Responsive Pressure Relief Device) |
- |
400 |
|
- |
6.3.1(Temperature Responsive Pressure Relief Device) |
- |
4000 |
|
- |
6.4.1(Handles and Knobs) |
- |
300 |
|
- |
6.4.1.1(Handles and Knobs) |
- |
300 |
|
- |
7.1(WORKMANSHIP AND FINISH) |
- |
300 |
|
- |
7.2(WORKMANSHIP AND FINISH) |
- |
300 |
|
- |
7.3(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
7.4(WORKMANSHIP AND FINISH) |
- |
1000 |
|
- |
8.1(Air Pressure Test) |
- |
600 |
|
- |
8.2(Proof Pressure Test) |
- |
600 |
|
- |
8.3(Operating Test for Pressure Regulating Device) |
- |
800 |
|
- |
8.4(Test for Safety Pressure Relief Device) |
- |
800 |
|
- |
8.5(Bursting Pressure Test) |
- |
1000 |
|
- |
8.6.1(Tests for Removal of Lid under Pressure For Outer Lid Cooker) |
- |
900 |
|
- |
8.6.2(Tests for Removal of Lid under Pressure For inner Lid Cooker) |
- |
900 |
|
- |
8.7(Test for Spring Loaded Mechanism) |
- |
800 |
|
- |
8.8(Test for Spring Loaded Mechanism) |
- |
1200 |
|
- |
8.9(Test for Spring Loaded Mechanism) |
- |
1200 |
|
- |
8.1(testing of handles of the cooker) |
- |
1200 |
|
- |
8.4 Annex H-1.2(Test for SPRD - For Resettable Devices ) |
- |
800 |
|
- |
8.4 Annex H-1.1(Test for SPRD - For Destructible Devices ) |
- |
800 |
|
- |
8.10 (a)(Handles of the cooker- Resistance to Burning) |
- |
700 |
|
- |
8.10 (b)(Handles of the cooker- Heat Resistance) |
- |
700 |
|
- |
8.10 (c)(Handles of the cooker- Torque Strength) |
- |
700 |
|
- |
8.10 (d)(Handles of the cooker- Bending Strength) |
- |
700 |
|
- |
8.10 (e)(Handles of the cooker- Fatigue Resistance) |
- |
1200 |
|
- |
8.10 (f)(Handles of the cooker- Thermal Insualtion Test) |
- |
800 |
|
- |
8.10 NOTES (3)(Handles of the cooker - Proof Pressure) |
- |
300 |
|
- |
8.10 NOTES (4)(Handles of the cooker) |
- |
300 |
|
- |
8.10 NOTES (5)(Handles of the cooker) |
- |
300 |
|
- |
8.10 NOTES (6)(Handles of the cooker) |
- |
300 |
|
- |
8.11.1 (a)(External Coating (powder coating or ceramic coating or high temperature resistant liquid coating)) |
- |
800 |
|
- |
8.11.1 (b)(External Coating (powder coating or ceramic coating or high temperature resistant liquid coating)) |
- |
800 |
|
- |
8.11.1 (c)(External Coating (powder coating or ceramic coating or high temperature resistant liquid coating)) |
- |
800 |
|
- |
8.11.1.1 (Thermal shock test for externally coated cooker) |
- |
1200 |
|
- |
8.12(Internal Coating) |
- |
1300 |
|
- |
8.14(3 Ply Construction Cooker Body) |
- |
1000 |
|
- |
11(Marking) |
- |
300 |
|
- |
|
Complete
|
|
26 Sep, 2027 |
- - |
627 |
URS PRODUCTS AND TESTING PVT. LTD.
| IS 14756 (2022) |
Draft Indian Standard STAINLESS STEEL COOKWARE SPECIFICATION Second Revision of IS 14756 |
- |
-
|
12000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(Material) |
- |
500 |
|
- |
3.2(Material) |
- |
500 |
|
- |
3.3(Material) |
- |
500 |
|
- |
3.4(Material) |
- |
500 |
|
- |
3.5(Material) |
- |
500 |
|
- |
4.1 (Annex A)(Shapes and Dimensions) |
- |
500 |
|
- |
4.2 (Table 1)(Shapes and Dimensions) |
- |
500 |
|
- |
4.3(Shapes and Dimensions) |
- |
500 |
|
- |
4.4(Shapes and Dimensions) |
- |
500 |
|
- |
6.1(Staining Test) |
- |
1000 |
|
- |
6.2(Mechanical Shock Test (For Cladded Utensils only)) |
- |
1000 |
|
- |
6.3(Thermal Shock Test (For Cladded Utensils only)) |
- |
1000 |
|
- |
6.4(Dry Heat Test (For Cladded Utensils only)) |
- |
1500 |
|
- |
6.5(Coating Thickness Test (For Copper Deposit)) |
- |
1000 |
|
- |
6.6(3 Ply) |
- |
1000 |
|
- |
6.7.1(Nominal Capacity Test) |
- |
1000 |
|
- |
6.8.1(Tests on Tempered Glass Lid) |
- |
1000 |
|
- |
6.8.2(Tests on Tempered Glass Lid (Ball drop test)) |
- |
1000 |
|
- |
6.8.3(Tests on Tempered Glass Lid (thermal shock test)) |
- |
1000 |
|
- |
6.8.4.1(Tests on Tempered Glass Lid (Free Fall Test with rim facing down)) |
- |
1000 |
|
- |
6.8.4.2(Tests on Tempered Glass Lid (Free Fall Test without rim facing down)) |
- |
1000 |
|
- |
3.4(Material) |
- |
500 |
|
- |
3.5(Material) |
- |
500 |
|
- |
3.5(Material) |
- |
500 |
|
- |
3.5(Material) |
- |
500 |
|
- |
4.2 (Table 1)(Shapes and Dimensions) |
- |
500 |
|
- |
4.2(Shapes and Dimensions) |
- |
500 |
|
- |
5.1(Workmanship and Finish) |
- |
500 |
|
- |
5.1(Workmanship and Finish) |
- |
500 |
|
- |
5.1(Workmanship and Finish) |
- |
500 |
|
- |
5.2(Workmanship and Finish) |
- |
500 |
|
- |
5.3(Workmanship and Finish) |
- |
500 |
|
- |
5.3(Workmanship and Finish) |
- |
500 |
|
- |
5.3(Workmanship and Finish) |
- |
500 |
|
- |
5.3(Workmanship and Finish) |
- |
500 |
|
- |
5.3(Workmanship and Finish) |
- |
500 |
|
- |
5.3(Workmanship and Finish) |
- |
500 |
|
- |
5.4(Workmanship and Finish) |
- |
500 |
|
- |
5.5(Workmanship and Finish) |
- |
500 |
|
- |
5.6(Workmanship and Finish) |
- |
500 |
|
- |
6.1(Staining Test) |
- |
1000 |
|
- |
6.7.2(Nominal Capacity Test- Diameter) |
- |
1000 |
|
- |
6.8.1(Tests on Tempered Glass Lid) |
- |
1000 |
|
- |
|
Complete
|
|
26 Sep, 2027 |
- - |
628 |
Ace Test Labs & Metrology Pvt. Ltd.
| IS 550 : Part 1 (2022) |
Safes: Part 1 specification Fifth Revision |
- |
-
|
258000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Classification) |
- |
124999.97 |
|
- |
5.1(Dimensions) |
- |
10000 |
|
- |
5.2(Sizes) |
- |
10000 |
|
- |
5.2(Table-2)(Inside dimensions) |
- |
10000 |
|
- |
5.2(Table-2)(Tolerance on inside dimensions) |
- |
10000 |
|
- |
5.2(Table-2)(Internal volume) |
- |
10000 |
|
- |
5.2(Table-2)(Tolerance on interanal volume) |
- |
10000 |
|
- |
5.2(Table-2)(Minumum Weight) |
- |
10000 |
|
- |
5.2(Table-2)(Thickness of Plates (outer bodys& Door)) |
- |
10000 |
|
- |
5.2(Table-2)(Thickness of Door slab) |
- |
10000 |
|
- |
5.2(Table-2)(Thickness of door overbolt work) |
- |
10000 |
|
- |
5.2(Table-2)(Number of lock on the door) |
- |
10000 |
|
- |
5.2(Table-2)(Any other type of lock) |
- |
10000 |
|
- |
5.2(Table-2)(Number of bolt on hinge side) |
- |
10000 |
|
- |
5.2(Table-2)(Number of bolt on opposite hinge) |
- |
10000 |
|
- |
5.2(Table-2)(No.of bolt at the top) |
- |
10000 |
|
- |
5.2(Table-2)(No.of bolt at the bottom) |
- |
10000 |
|
- |
5.2(Table-2)(Size of each bolt (area of bolt section)) |
- |
10000 |
|
- |
5.2(Table-2)(Depth engagement of bolt) |
- |
10000 |
|
- |
6(Material declaration) |
- |
10000 |
|
- |
7(Desigantion-Delaration) |
- |
10000 |
|
- |
8.1(Body (Construction & workmanship)) |
- |
10000 |
|
- |
8.2(Door (Gap)) |
- |
10000 |
|
- |
8.4.1(Hinges) |
- |
10000 |
|
- |
8.4.2(Bolts) |
- |
10000 |
|
- |
8.5(Handle) |
- |
10000 |
|
- |
8.6.1(Lock (key type) Garde) |
- |
10000 |
|
- |
8.6.1(Lock (key type)classification) |
- |
10000 |
|
- |
8.6.1(Lock (key type)construction) |
- |
10000 |
|
- |
8.6.1(Lock(key type) leaver thickness) |
- |
10000 |
|
- |
8.6.1(Lock (key type)Material) |
- |
10000 |
|
- |
8.6.1(Lock (key type)corrosion protection materail) |
- |
10000 |
|
- |
8.6.1(Lock(key type) -Endurance test) |
- |
10000 |
|
- |
8.6.1(Lock(key type)-Bolt forcing test) |
- |
10000 |
|
- |
8.6.1(Lock(key type)-salt spray solution test) |
- |
10000 |
|
- |
8.6.1(Lock(key type)-key strength test) |
- |
10000 |
|
- |
8.6.1(Lock(key type) -Marking) |
- |
10000 |
|
- |
8.6.1(Lock(Key type) -Key Marking) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock -Classification) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock -Construction) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock -Metallic parts) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock -Corrosion Prot) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock -Operation test) |
- |
10000 |
|
- |
8.6.1(Mechanical cmbination lock -Manipulation) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock -Punching attack) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock -Endurance test) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock-Salt spary test) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock-Strength test) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock-Aging-stress Dist) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock-Moisture Absorp) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock-Vibration test) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock-Marking) |
- |
10000 |
|
- |
8.6.1(Any other lock) |
- |
10000 |
|
- |
8.6.4(Lock Bolt engagement) |
- |
10000 |
|
- |
8.6.5(Additional provision- retrofitting time lock) |
- |
10000 |
|
- |
8.7(Automatic re-locking device) |
- |
10000 |
|
- |
8.8(Cable hole size) |
- |
10000 |
|
- |
9(Internal fixture) |
- |
10000 |
|
- |
10(Painting) |
- |
10000 |
|
- |
10.1(Cross hatch test) |
- |
10000 |
|
- |
11.1(Marking of safe) |
- |
10000 |
|
- |
12(Burglary attack) |
- |
99999.97 |
|
- |
12(Fire Resistance) |
- |
150000 |
|
- |
4(Classification) |
- |
100000 |
|
- |
5.1(Dimensions) |
- |
10000 |
|
- |
5.2(Sizes) |
- |
10000 |
|
- |
5.2(Table-2)(Inside dimensions) |
- |
10000 |
|
- |
5.2(Table-2)(Tolerance on inside dimensions) |
- |
10000 |
|
- |
5.2(Table-2)(Internal volume) |
- |
10000 |
|
- |
5.2(Table-2)(Tolerance on interanal volume) |
- |
10000 |
|
- |
5.2(Table-2)(Minumum Weight) |
- |
10000 |
|
- |
5.2(Table-2)(Thickness of Plates (outer bodys& Door)) |
- |
10000 |
|
- |
5.2(Table-2)(Thickness of Door slab) |
- |
10000 |
|
- |
5.2(Table-2)(Thickness of door overbolt work) |
- |
10000 |
|
- |
5.2(Table-2)(Number of lock on the door) |
- |
10000 |
|
- |
5.2(Table-2)(Any other type of lock) |
- |
10000 |
|
- |
5.2(Table-2)(Number of bolt on hinge side) |
- |
10000 |
|
- |
5.2(Table-2)(Number of bolt on opposite hinge) |
- |
10000 |
|
- |
5.2(Table-2)(No.of bolt at the top) |
- |
10000 |
|
- |
5.2(Table-2)(No.of bolt at the bottom) |
- |
10000 |
|
- |
5.2(Table-2)(Size of each bolt (area of bolt section)) |
- |
10000 |
|
- |
5.2(Table-2)(Depth engagement of bolt) |
- |
10000 |
|
- |
6(Material declaration) |
- |
10000 |
|
- |
7(Desigantion-Delaration) |
- |
10000 |
|
- |
8.1(Body (Construction & workmanship)) |
- |
10000 |
|
- |
8.2(Door (Gap)) |
- |
10000 |
|
- |
8.4.1(Hinges) |
- |
10000 |
|
- |
8.4.2(Bolts) |
- |
10000 |
|
- |
8.5(Handle) |
- |
10000 |
|
- |
8.6.1(Lock (key type) Garde) |
- |
10000 |
|
- |
8.6.1(Lock (key type)classification) |
- |
10000 |
|
- |
8.6.1(Lock (key type)construction) |
- |
10000 |
|
- |
8.6.1(Lock(key type) leaver thickness) |
- |
10000 |
|
- |
8.6.1(Lock (key type)Material) |
- |
10000 |
|
- |
8.6.1(Lock (key type)corrosion protection materail) |
- |
10000 |
|
- |
8.6.1(Lock(key type) -Endurance test) |
- |
10000 |
|
- |
8.6.1(Lock(key type)-Bolt forcing test) |
- |
10000 |
|
- |
8.6.1(Lock(key type)-salt spray solution test) |
- |
10000 |
|
- |
8.6.1(Lock(key type)-key strength test) |
- |
10000 |
|
- |
8.6.1(Lock(key type) -Marking) |
- |
10000 |
|
- |
8.6.1(Lock(Key type) -Key Marking) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock -Classification) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock -Construction) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock -Metallic parts) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock -Corrosion Prot) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock -Operation test) |
- |
10000 |
|
- |
8.6.1(Mechanical cmbination lock -Manipulation) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock -Punching attack) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock -Endurance test) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock-Salt spary test) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock-Strength test) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock-Aging-stress Dist) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock-Moisture Absorp) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock-Vibration test) |
- |
10000 |
|
- |
8.6.1(Mechanical combination lock-Marking) |
- |
10000 |
|
- |
8.6.1(Any other lock) |
- |
10000 |
|
- |
8.6.4(Lock Bolt engagement) |
- |
10000 |
|
- |
8.6.5(Additional provision- retrofitting time lock) |
- |
10000 |
|
- |
8.7(Automatic re-locking device) |
- |
10000 |
|
- |
8.8(Cable hole size) |
- |
10000 |
|
- |
9(Internal fixture) |
- |
10000 |
|
- |
10(Painting) |
- |
10000 |
|
- |
10.1(Cross hatch test) |
- |
10000 |
|
- |
11.1(Marking of safe) |
- |
10000 |
|
- |
12(Burglary attack) |
- |
100000 |
|
- |
12(Fire Resistance) |
- |
150000 |
|
- |
|
Complete
|
|
14 Nov, 2027 |
- Included w.e.f. 28.03.2025 |
629 |
Atmy Analytical Labs Private Limited (Unit-2)
| IS 17541 (2021) |
Modular panel for security of premises specification |
- |
-
|
546000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause-5(Dimensions) |
- |
0 |
|
- |
Clause-6(Materials) |
- |
0 |
|
- |
Clause-8(Construction and General Requirements) |
- |
0 |
|
- |
Clause-9(Fittings) |
- |
0 |
|
- |
Clause-10(Finish) |
- |
0 |
|
- |
Clause-10.1(Cross Hatch Test) |
- |
0 |
|
- |
Clause-11.2, 1(Full length panel (Continuous design panel)) |
- |
0 |
|
- |
Clause-11.2, 2(Assemble panel/Segmented panel) |
- |
0 |
|
- |
Clause-12(Marking) |
- |
0 |
|
- |
Clause-5(Dimensions) |
- |
0 |
|
- |
Clause-6(Materials) |
- |
0 |
|
- |
Clause-8(Construction and General Requirements) |
- |
0 |
|
- |
Clause-9(Fittings) |
- |
0 |
|
- |
Clause-10(Finish) |
- |
0 |
|
- |
Clause-10.1(Cross Hatch Test) |
- |
0 |
|
- |
Clause-11.2, 1(Full length panel (Continuous design panel)) |
- |
0 |
|
- |
Clause-11.2, 2(Assemble panel/Segmented panel) |
- |
0 |
|
- |
Clause-12(Marking) |
- |
0 |
|
- |
|
Complete
|
|
08 Feb, 2027 |
- Included w.e.f. 01.04.2025 |
630 |
Atmy Analytical Labs Private Limited (Unit-2)
| IS 550 : Part 1 (2022) |
Safes: Part 1 specification Fifth Revision |
- |
-
|
380000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Classification) |
- |
0 |
|
- |
5.1(Dimensions) |
- |
0 |
|
- |
5.2(Sizes) |
- |
0 |
|
- |
5.2(Table-2)(Inside dimensions) |
- |
0 |
|
- |
5.2(Table-2)(Tolerance on inside dimensions) |
- |
0 |
|
- |
5.2(Table-2)(Internal volume) |
- |
0 |
|
- |
5.2(Table-2)(Tolerance on interanal volume) |
- |
0 |
|
- |
5.2(Table-2)(Minumum Weight) |
- |
0 |
|
- |
5.2(Table-2)(Thickness of Plates (outer bodys& Door)) |
- |
0 |
|
- |
5.2(Table-2)(Thickness of Door slab) |
- |
0 |
|
- |
5.2(Table-2)(Thickness of door overbolt work) |
- |
0 |
|
- |
5.2(Table-2)(Number of lock on the door) |
- |
0 |
|
- |
5.2(Table-2)(Any other type of lock) |
- |
0 |
|
- |
5.2(Table-2)(Number of bolt on hinge side) |
- |
0 |
|
- |
5.2(Table-2)(Number of bolt on opposite hinge) |
- |
0 |
|
- |
5.2(Table-2)(No.of bolt at the top) |
- |
0 |
|
- |
5.2(Table-2)(No.of bolt at the bottom) |
- |
0 |
|
- |
5.2(Table-2)(Size of each bolt (area of bolt section)) |
- |
0 |
|
- |
5.2(Table-2)(Depth engagement of bolt) |
- |
0 |
|
- |
6(Material declaration) |
- |
0 |
|
- |
7(Desigantion-Delaration) |
- |
0 |
|
- |
8.1(Body (Construction & workmanship)) |
- |
0 |
|
- |
8.2(Door (Gap)) |
- |
0 |
|
- |
8.4.1(Hinges) |
- |
0 |
|
- |
8.4.2(Bolts) |
- |
0 |
|
- |
8.5(Handle) |
- |
0 |
|
- |
8.6.1(Lock (key type) Garde) |
- |
0 |
|
- |
8.6.1(Lock (key type)classification) |
- |
0 |
|
- |
8.6.1(Lock (key type)construction) |
- |
0 |
|
- |
8.6.1(Lock(key type) leaver thickness) |
- |
0 |
|
- |
8.6.1(Lock (key type)Material) |
- |
0 |
|
- |
8.6.1(Lock (key type)corrosion protection materail) |
- |
0 |
|
- |
8.6.1(Lock(key type) -Endurance test) |
- |
0 |
|
- |
8.6.1(Lock(key type)-Bolt forcing test) |
- |
0 |
|
- |
8.6.1(Lock(key type)-salt spray solution test) |
- |
0 |
|
- |
8.6.1(Lock(key type)-key strength test) |
- |
0 |
|
- |
8.6.1(Lock(key type) -Marking) |
- |
0 |
|
- |
8.6.1(Lock(Key type) -Key Marking) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Classification) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Construction) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Metallic parts) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Corrosion Prot) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Operation test) |
- |
0 |
|
- |
8.6.1(Mechanical cmbination lock -Manipulation) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Punching attack) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Endurance test) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock-Salt spary test) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock-Strength test) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock-Aging-stress Dist) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock-Moisture Absorp) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock-Vibration test) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock-Marking) |
- |
0 |
|
- |
8.6.1(Any other lock) |
- |
0 |
|
- |
8.6.4(Lock Bolt engagement) |
- |
0 |
|
- |
8.6.5(Additional provision- retrofitting time lock) |
- |
0 |
|
- |
8.7(Automatic re-locking device) |
- |
0 |
|
- |
8.8(Cable hole size) |
- |
0 |
|
- |
9(Internal fixture) |
- |
0 |
|
- |
10(Painting) |
- |
0 |
|
- |
10.1(Cross hatch test) |
- |
0 |
|
- |
11.1(Marking of safe) |
- |
0 |
|
- |
12(Burglary attack) |
- |
0 |
|
- |
12(Fire Resistance) |
- |
0 |
|
- |
4(Classification) |
- |
0 |
|
- |
5.1(Dimensions) |
- |
0 |
|
- |
5.2(Sizes) |
- |
0 |
|
- |
5.2(Table-2)(Inside dimensions) |
- |
0 |
|
- |
5.2(Table-2)(Tolerance on inside dimensions) |
- |
0 |
|
- |
5.2(Table-2)(Internal volume) |
- |
0 |
|
- |
5.2(Table-2)(Tolerance on interanal volume) |
- |
0 |
|
- |
5.2(Table-2)(Minumum Weight) |
- |
0 |
|
- |
5.2(Table-2)(Thickness of Plates (outer bodys& Door)) |
- |
0 |
|
- |
5.2(Table-2)(Thickness of Door slab) |
- |
0 |
|
- |
5.2(Table-2)(Thickness of door overbolt work) |
- |
0 |
|
- |
5.2(Table-2)(Number of lock on the door) |
- |
0 |
|
- |
5.2(Table-2)(Any other type of lock) |
- |
0 |
|
- |
5.2(Table-2)(Number of bolt on hinge side) |
- |
0 |
|
- |
5.2(Table-2)(Number of bolt on opposite hinge) |
- |
0 |
|
- |
5.2(Table-2)(No.of bolt at the top) |
- |
0 |
|
- |
5.2(Table-2)(No.of bolt at the bottom) |
- |
0 |
|
- |
5.2(Table-2)(Size of each bolt (area of bolt section)) |
- |
0 |
|
- |
5.2(Table-2)(Depth engagement of bolt) |
- |
0 |
|
- |
6(Material declaration) |
- |
0 |
|
- |
7(Desigantion-Delaration) |
- |
0 |
|
- |
8.1(Body (Construction & workmanship)) |
- |
0 |
|
- |
8.2(Door (Gap)) |
- |
0 |
|
- |
8.4.1(Hinges) |
- |
0 |
|
- |
8.4.2(Bolts) |
- |
0 |
|
- |
8.5(Handle) |
- |
0 |
|
- |
8.6.1(Lock (key type) Garde) |
- |
0 |
|
- |
8.6.1(Lock (key type)classification) |
- |
0 |
|
- |
8.6.1(Lock (key type)construction) |
- |
0 |
|
- |
8.6.1(Lock(key type) leaver thickness) |
- |
0 |
|
- |
8.6.1(Lock (key type)Material) |
- |
0 |
|
- |
8.6.1(Lock (key type)corrosion protection materail) |
- |
0 |
|
- |
8.6.1(Lock(key type) -Endurance test) |
- |
0 |
|
- |
8.6.1(Lock(key type)-Bolt forcing test) |
- |
0 |
|
- |
8.6.1(Lock(key type)-salt spray solution test) |
- |
0 |
|
- |
8.6.1(Lock(key type)-key strength test) |
- |
0 |
|
- |
8.6.1(Lock(key type) -Marking) |
- |
0 |
|
- |
8.6.1(Lock(Key type) -Key Marking) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Classification) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Construction) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Metallic parts) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Corrosion Prot) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Operation test) |
- |
0 |
|
- |
8.6.1(Mechanical cmbination lock -Manipulation) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Punching attack) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Endurance test) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock-Salt spary test) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock-Strength test) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock-Aging-stress Dist) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock-Moisture Absorp) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock-Vibration test) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock-Marking) |
- |
0 |
|
- |
8.6.1(Any other lock) |
- |
0 |
|
- |
8.6.4(Lock Bolt engagement) |
- |
0 |
|
- |
8.6.5(Additional provision- retrofitting time lock) |
- |
0 |
|
- |
8.7(Automatic re-locking device) |
- |
0 |
|
- |
8.8(Cable hole size) |
- |
0 |
|
- |
9(Internal fixture) |
- |
0 |
|
- |
10(Painting) |
- |
0 |
|
- |
10.1(Cross hatch test) |
- |
0 |
|
- |
11.1(Marking of safe) |
- |
0 |
|
- |
12(Burglary attack) |
- |
0 |
|
- |
12(Fire Resistance) |
- |
0 |
|
- |
4(Classification) |
- |
0 |
|
- |
5.1(Dimensions) |
- |
0 |
|
- |
5.2(Sizes) |
- |
0 |
|
- |
5.2(Table-2)(Inside dimensions) |
- |
0 |
|
- |
5.2(Table-2)(Tolerance on inside dimensions) |
- |
0 |
|
- |
5.2(Table-2)(Internal volume) |
- |
0 |
|
- |
5.2(Table-2)(Tolerance on interanal volume) |
- |
0 |
|
- |
5.2(Table-2)(Minumum Weight) |
- |
0 |
|
- |
5.2(Table-2)(Thickness of Plates (outer bodys& Door)) |
- |
0 |
|
- |
5.2(Table-2)(Thickness of Door slab) |
- |
0 |
|
- |
5.2(Table-2)(Thickness of door overbolt work) |
- |
0 |
|
- |
5.2(Table-2)(Number of lock on the door) |
- |
0 |
|
- |
5.2(Table-2)(Any other type of lock) |
- |
0 |
|
- |
5.2(Table-2)(Number of bolt on hinge side) |
- |
0 |
|
- |
5.2(Table-2)(Number of bolt on opposite hinge) |
- |
0 |
|
- |
5.2(Table-2)(No.of bolt at the top) |
- |
0 |
|
- |
5.2(Table-2)(No.of bolt at the bottom) |
- |
0 |
|
- |
5.2(Table-2)(Size of each bolt (area of bolt section)) |
- |
0 |
|
- |
5.2(Table-2)(Depth engagement of bolt) |
- |
0 |
|
- |
6(Material declaration) |
- |
0 |
|
- |
7(Desigantion-Delaration) |
- |
0 |
|
- |
8.1(Body (Construction & workmanship)) |
- |
0 |
|
- |
8.2(Door (Gap)) |
- |
0 |
|
- |
8.4.1(Hinges) |
- |
0 |
|
- |
8.4.2(Bolts) |
- |
0 |
|
- |
8.5(Handle) |
- |
0 |
|
- |
8.6.1(Lock (key type) Garde) |
- |
0 |
|
- |
8.6.1(Lock (key type)classification) |
- |
0 |
|
- |
8.6.1(Lock (key type)construction) |
- |
0 |
|
- |
8.6.1(Lock(key type) leaver thickness) |
- |
0 |
|
- |
8.6.1(Lock (key type)Material) |
- |
0 |
|
- |
8.6.1(Lock (key type)corrosion protection materail) |
- |
0 |
|
- |
8.6.1(Lock(key type) -Endurance test) |
- |
0 |
|
- |
8.6.1(Lock(key type)-Bolt forcing test) |
- |
0 |
|
- |
8.6.1(Lock(key type)-salt spray solution test) |
- |
0 |
|
- |
8.6.1(Lock(key type)-key strength test) |
- |
0 |
|
- |
8.6.1(Lock(key type) -Marking) |
- |
0 |
|
- |
8.6.1(Lock(Key type) -Key Marking) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Classification) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Construction) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Metallic parts) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Corrosion Prot) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Operation test) |
- |
0 |
|
- |
8.6.1(Mechanical cmbination lock -Manipulation) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Punching attack) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock -Endurance test) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock-Salt spary test) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock-Strength test) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock-Aging-stress Dist) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock-Moisture Absorp) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock-Vibration test) |
- |
0 |
|
- |
8.6.1(Mechanical combination lock-Marking) |
- |
0 |
|
- |
8.6.1(Any other lock) |
- |
0 |
|
- |
8.6.4(Lock Bolt engagement) |
- |
0 |
|
- |
8.6.5(Additional provision- retrofitting time lock) |
- |
0 |
|
- |
8.7(Automatic re-locking device) |
- |
0 |
|
- |
8.8(Cable hole size) |
- |
0 |
|
- |
9(Internal fixture) |
- |
0 |
|
- |
10(Painting) |
- |
0 |
|
- |
10.1(Cross hatch test) |
- |
0 |
|
- |
11.1(Marking of safe) |
- |
0 |
|
- |
12(Burglary attack) |
- |
0 |
|
- |
12(Fire Resistance) |
- |
0 |
|
- |
|
Complete
|
|
08 Feb, 2027 |
- Included w.e.f. 01.04.2025 |