| 6871 |
BIS, Central Laboratory (CL)
| None
| IS 4766 (2024) |
Thiram water dispersible powder for slurry seed treatment - Specification (second revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| CL 3.1 (Description) |
- |
|
|
|
| CL 3.3, Table 1, S.No (i) (Thiram Content) |
- |
|
|
|
| CL 3.3, Table 1, S.No (ii) (Sieving) |
- |
|
|
|
| CL 3.3, Table 1, S.No (iii) (Wettability) |
- |
|
|
|
|
- |
- - |
| 6872 |
Bharat Test House Pvt Ltd 781 Sonipat Haryana
| 9137826
| IS 302 : Part 2 : Sec 207 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 207 electric hot plates |
Electric hot plates |
22500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General) |
- |
0 |
|
- |
| 5(Rating) |
- |
100 |
|
- |
| 6(Classification) |
- |
100 |
|
- |
| 7(Marking) |
- |
100 |
|
- |
| 11(TEMPERATURE RISE) |
- |
1500 |
|
- |
| 12("OPERATION UNDER OVERLOAD
CONDITIONS OF APPLIANCES WITH
HEATING ELEMENTS") |
- |
1000 |
|
- |
| 13(" ELECTRICAL INSULATION AND LEKAGE
CURRENT AT OPERATING TEMPERATURE ") |
- |
800 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
3000 |
|
- |
| 16("INSULATION RESlSTANCE AND
specified in 16.2.
ELECTRIC SHOCK STRENGTH ( AFTER
HUMIDITY TREATMENT )") |
- |
800 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
2000 |
|
- |
| 20("STABILITY AND MECHANICAL
HAZARDS") |
- |
500 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
800 |
|
- |
| 22(CONSTRUCTION) |
- |
2000 |
|
- |
| 23(INTERNAL WIRING) |
- |
500 |
|
- |
| 24(COMPONENTS) |
- |
500 |
|
- |
| 25("SUPPLY CONNECTION AND EXTERNAL
FLEXIBLE CABLES AND CORDS ") |
- |
750 |
|
- |
| 26("TERMINALS FOR EXTERNAL
CONDUCTORS") |
- |
500 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
500 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
600 |
|
- |
| 30("RESISTANCE TO HEAT, FIRE AND
TRACKING ") |
- |
2000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
750 |
|
- |
| 8("PROTECTION AGAINST ELECTRIC
SHOCK ") |
- |
500 |
|
- |
|
31 Dec, 2026 |
- Included.w.e.f.13.11.2024. Exclusion : 19.11.4.1 to 19.11.4.7 (EMI/EMC) |
| 6873 |
Hi Physix Laboratory India Private Limited, Pune
| 7126926
| IS 2993 : Part 1 (2024) |
a.c. Motor Capacitors Part 1 General - Performance, Testing and Rating - Safety Requirements - Guidance for Installation and Operation ( Third Revision ) |
- |
455750 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.1(General) |
- |
4000 |
|
- |
| 5.5(Tangent of loss angle) |
- |
18000 |
|
- |
| 5.7("Voltage test between terminals
") |
- |
9000 |
|
- |
| 5.8(Voltage test between terminals and case) |
- |
9000 |
|
- |
| 5.9(Capacitance measurement) |
- |
13500 |
|
- |
| 5.9(Capacitance measurement) |
- |
0 |
|
- |
| 5.1(Check of dimensions) |
- |
4000 |
|
Actual Cl. no. is 5.10 |
| 5.11(Mechanical tests) |
- |
62500 |
|
- |
| 5.12(Sealing test) |
- |
9000 |
|
- |
| 5.13(Endurance test) |
- |
192500 |
|
- |
| 5.14(Damp heat test) |
- |
66000 |
|
- |
| 5.15(Self-healing test) |
- |
9000 |
|
- |
| 5.16(Destruction test) |
- |
44250 |
|
- |
| 5.17(Resistance to heat, fire and tracking) |
- |
0 |
|
- |
| 5.17.1(Ball-pressure test) |
- |
3000 |
|
- |
| 5.17.2(Glow-wire test) |
- |
3000 |
|
- |
| 5.17.3(Tracking test) |
- |
5000 |
|
- |
| 6.1(Maximum permissible voltage) |
- |
0 |
|
- |
| 6.2("Maximum permissible current
") |
- |
0 |
|
- |
| 6.3(Maximum permissible reactive output) |
- |
0 |
|
- |
| 7(Safety requirements) |
- |
0 |
|
- |
| 7.1(Requirements for Creepage distances and clearances) |
- |
0 |
|
- |
| 7.2(Terminals and connecting cables) |
- |
0 |
|
- |
| 7.3(Earth connections) |
- |
0 |
|
- |
| 7.4(Discharge devices) |
- |
0 |
|
- |
| 8(Marking) |
- |
4000 |
|
- |
| 9.2.1(Measurements of working voltage) |
- |
0 |
|
- |
| 9.2.2(Influence of capacitance) |
- |
0 |
|
- |
| 9.3(Checking capacitor temperature) |
- |
0 |
|
- |
| 9.4(Checking transients) |
- |
0 |
|
- |
| 9.5(Leakage current) |
- |
0 |
|
- |
| 5.1.1(General) |
- |
0 |
|
- |
| 5.5(Tangent of loss angle) |
- |
0 |
|
- |
| 5.7("Voltage test between terminals
") |
- |
0 |
|
- |
| 5.8(Voltage test between terminals and case) |
- |
0 |
|
- |
| 5.9(Capacitance measurement) |
- |
0 |
|
- |
| 5.9(Capacitance measurement) |
- |
0 |
|
- |
| 5.1(Check of dimensions) |
- |
0 |
|
- |
| 5.11(Mechanical tests) |
- |
0 |
|
- |
| 5.12(Sealing test) |
- |
0 |
|
- |
| 5.13(Endurance test) |
- |
0 |
|
- |
| 5.14(Damp heat test) |
- |
0 |
|
- |
| 5.15(Self-healing test) |
- |
0 |
|
- |
| 5.16(Destruction test) |
- |
0 |
|
- |
| 5.17(Resistance to heat, fire and tracking) |
- |
0 |
|
- |
| 5.17.1(Ball-pressure test) |
- |
0 |
|
- |
| 5.17.2(Glow-wire test) |
- |
0 |
|
- |
| 5.17.3(Tracking test) |
- |
0 |
|
- |
| 6.1(Maximum permissible voltage) |
- |
0 |
|
- |
| 6.2("Maximum permissible current
") |
- |
0 |
|
- |
| 6.3(Maximum permissible reactive output) |
- |
0 |
|
- |
| 7(Safety requirements) |
- |
0 |
|
- |
| 7.1(Requirements for Creepage distances and clearances) |
- |
0 |
|
- |
| 7.2(Terminals and connecting cables) |
- |
0 |
|
- |
| 7.3(Earth connections) |
- |
0 |
|
- |
| 7.4(Discharge devices) |
- |
0 |
|
- |
| 8(Marking) |
- |
0 |
|
- |
| 9.2.1(Measurements of working voltage) |
- |
0 |
|
- |
| 9.2.2(Influence of capacitance) |
- |
0 |
|
- |
| 9.3(Checking capacitor temperature) |
- |
0 |
|
- |
| 9.4(Checking transients) |
- |
0 |
|
- |
| 9.5(Leakage current) |
- |
0 |
|
- |
| 5.1.1(General) |
- |
0 |
|
- |
| 5.5(Tangent of loss angle) |
- |
0 |
|
- |
| 5.7("Voltage test between terminals
") |
- |
0 |
|
- |
| 5.8(Voltage test between terminals and case) |
- |
0 |
|
- |
| 5.9(Capacitance measurement) |
- |
0 |
|
- |
| 5.9(Capacitance measurement) |
- |
0 |
|
- |
| 5.1(Check of dimensions) |
- |
0 |
|
- |
| 5.11(Mechanical tests) |
- |
0 |
|
- |
| 5.12(Sealing test) |
- |
0 |
|
- |
| 5.13(Endurance test) |
- |
0 |
|
- |
| 5.14(Damp heat test) |
- |
0 |
|
- |
| 5.15(Self-healing test) |
- |
0 |
|
- |
| 5.16(Destruction test) |
- |
0 |
|
- |
| 5.17(Resistance to heat, fire and tracking) |
- |
0 |
|
- |
| 5.17.1(Ball-pressure test) |
- |
0 |
|
- |
| 5.17.2(Glow-wire test) |
- |
0 |
|
- |
| 5.17.3(Tracking test) |
- |
0 |
|
- |
| 6.1(Maximum permissible voltage) |
- |
0 |
|
- |
| 6.2("Maximum permissible current
") |
- |
0 |
|
- |
| 6.3(Maximum permissible reactive output) |
- |
0 |
|
- |
| 7(Safety requirements) |
- |
0 |
|
- |
| 7.1(Requirements for Creepage distances and clearances) |
- |
0 |
|
- |
| 7.2(Terminals and connecting cables) |
- |
0 |
|
- |
| 7.3(Earth connections) |
- |
0 |
|
- |
| 7.4(Discharge devices) |
- |
0 |
|
- |
| 8(Marking) |
- |
0 |
|
- |
| 9.2.1(Measurements of working voltage) |
- |
0 |
|
- |
| 9.2.2(Influence of capacitance) |
- |
0 |
|
- |
| 9.3(Checking capacitor temperature) |
- |
0 |
|
- |
| 9.4(Checking transients) |
- |
0 |
|
- |
| 9.5(Leakage current) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f.08.11.2024 |
| 6874 |
IDMA LABORATORIES LIMITED, PANCHKULA
| 9123236
| IS 2630 (2021) |
NITROBENZENE SPECIFICATION |
- |
29000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 3.1(Description) |
- |
1000 |
|
- |
| Clause 3.2
Table 1(i)(Relative density
at 27 °C/27 °C) |
- |
2500 |
|
- |
| Clause 3.2
Table 1(ii)(Distillation range
at 760 mm Hg.) |
- |
4000 |
|
- |
| Clause 3.2
Table 1(iii)(Crystallization
point °C, Min) |
- |
3000 |
|
- |
| Clause 3.2
Table 1(iv)(Moisture, percent
by Mass, Max) |
- |
2500 |
|
- |
| Clause 3.2
Table 1(v)(pH, Min) |
- |
1500 |
|
- |
| Clause 3.2
Table 1(vi)(Dinitrobenzene, percent
by Mass, Max) |
- |
3000 |
|
- |
| Clause 3.2
Table 1(vii)(Assay, percent by Mass, Max) |
- |
4000 |
|
- |
| Clause 3.2
Table 1(viii)(Low boilers (Benzene)
percent by Mass, Max) |
- |
3500 |
|
- |
| Clause 3.2
Table 1(ix)(High boilers (o-nitrotoluene,
p-nitrotoluene, p-nitrochlorobenzene, and
m-dinitrobenzene), percent by mass, Max) |
- |
4000 |
|
- |
| Clause 4.1(Packing) |
- |
0 |
|
Test not applicable |
| Clause 4.2(Marking) |
- |
0 |
|
Test not Applicable |
| Clause 3.1(Description) |
- |
1000 |
|
- |
| Clause 3.2
Table 1(i)(Relative density
at 27 °C/27 °C) |
- |
2500 |
|
- |
| Clause 3.2
Table 1(ii)(Distillation range
at 760 mm Hg.) |
- |
4000 |
|
- |
| Clause 3.2
Table 1(iii)(Crystallization
point °C, Min) |
- |
3000 |
|
- |
| Clause 3.2
Table 1(iv)(Moisture, percent
by Mass, Max) |
- |
2500 |
|
- |
| Clause 3.2
Table 1(v)(pH, Min) |
- |
1500 |
|
- |
| Clause 3.2
Table 1(vi)(Dinitrobenzene, percent
by Mass, Max) |
- |
3000 |
|
- |
| Clause 3.2
Table 1(vii)(Assay, percent by Mass, Max) |
- |
4000 |
|
- |
| Clause 3.2
Table 1(viii)(Low boilers (Benzene)
percent by Mass, Max) |
- |
3500 |
|
- |
| Clause 3.2
Table 1(ix)(High boilers (o-nitrotoluene,
p-nitrotoluene, p-nitrochlorobenzene, and
m-dinitrobenzene), percent by mass, Max) |
- |
4000 |
|
- |
| Clause 4.1(Packing) |
- |
0 |
|
Test not applicable |
| Clause 4.2(Marking) |
- |
0 |
|
Test not applicable |
|
31 Dec, 2026 |
- Included w.e.f 09.10.2024 |
| 6875 |
Central Institute of Petrochemicals Engineering & Technology (CIPET), Chandrapur
| 7173804
| IS 7180 (1973) |
Specification for disposable artificial insemination gloves |
Disposable Artificial Insemination Gloves |
7450.0 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.1(Glove Material) |
- |
1050.0 |
|
GST EXTRA |
| 3.1(Thickness) |
- |
1000.0 |
|
Charges Including Clause 3 & 3.2
GST EXTRA |
| 4.1(Appearance) |
- |
500.0 |
|
GST EXTRA |
| 5.1(Tensile Strength of the film) |
- |
2600.0 |
|
Charges 1300.0 + 1300.0 = 2600.0 (Lengthwise & Widthwise)
GST EXTRA |
| 7.1(Density) |
- |
700.0 |
|
GST EXTRA |
| 10.2(Marking) |
- |
1600.0 |
|
Charges Including for Clause 8 =500.0, Clause 9 =600.0 & Clause 12.1 =500.0
GST EXTRA |
| 2.1(Glove Material) |
- |
0.00 |
|
- |
| 3.1(Thickness) |
- |
0.00 |
|
- |
| 4.1(Appearance) |
- |
0.00 |
|
- |
| 5.1(Tensile Strength of the film) |
- |
0.00 |
|
- |
| 7.1(Density) |
- |
0.00 |
|
- |
| 10.2(Marking) |
- |
0.00 |
|
- |
| 2.1(Glove Material) |
- |
0.00 |
|
- |
| 3.1(Thickness) |
- |
0.00 |
|
- |
| 4.1(Appearance) |
- |
0.00 |
|
- |
| 5.1(Tensile Strength of the film) |
- |
0.00 |
|
- |
| 7.1(Density) |
- |
0.00 |
|
- |
| 10.2(Marking) |
- |
0.00 |
|
- |
| 2.1(Glove Material) |
- |
0.00 |
|
- |
| 3.1(Thickness) |
- |
0.00 |
|
- |
| 4.1(Appearance) |
- |
0.00 |
|
- |
| 5.1(Tensile Strength of the film) |
- |
0.00 |
|
- |
| 7.1(Density) |
- |
0.00 |
|
- |
| 10.2(Marking) |
- |
0.00 |
|
- |
|
10 Sep, 2026 |
- Included w.e.f 19.09.2024 |
| 6876 |
WELL TECH TEST AND RESEARCH CENTER, DERABASSI
| 9177306
| IS 7092 : Part 2 (1987) |
Specification for aluminium alloy tube for irrigation purposes: Part 2 extruded tube (Second Revision) |
TABLE 2 |
17500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.4(Workmanship & Finish) |
- |
1000 |
|
- |
| Cl.6.2(Ultimate Tensile Strength- IS 2657) |
- |
2000 |
|
- |
| Cl.6.2(0.2 percent proof strength- IS 2657) |
- |
2000 |
|
- |
| Cl.6.2(Elongation on 50 mm gauge length- IS 2657) |
- |
1500 |
|
- |
| Cl. 6.3(Drift Expanding Test ( Expanded Inside Diameter- IS 2335) |
- |
2500 |
|
- |
| Cl. 6.4(Hydrostatic Pressure Test-Cl. 6.4) |
- |
2500 |
|
- |
| Cl.7.1, Table 2(Outside Diameter-) |
- |
1000 |
|
- |
| Cl.7.1, Table 2(Roundness or Ovality) |
- |
1000 |
|
- |
| Cl.7.1, Table 2(Wall Thickness) |
- |
1000 |
|
- |
| Cl. 7.2(Length) |
- |
500 |
|
- |
| Cl. 6.1(Copper- IS 504 or any other established instrumental/ chemical method) |
- |
500 |
|
- |
| Cl. 6.1(Magnesium- IS 504 or any other established instrumental/ chemical method) |
- |
500 |
|
- |
| Cl. 6.1(Silicon- IS 504 or any other established instrumental/ chemical method) |
- |
500 |
|
- |
| Cl. 6.1(Iron- IS 504 or any other established instrumental/ chemical method) |
- |
500 |
|
- |
| Cl. 6.1(Manganese- IS 504 or any other established instrumental/ chemical method) |
- |
500 |
|
- |
| Cl. 6.1(Zinc- IS 504 or any other established instrumental/ chemical method) |
- |
500 |
|
- |
| Cl. 6.1(Chromium- IS 504 or any other established instrumental/ chemical method) |
- |
500 |
|
- |
| Cl. 6.1(Titanium and/ other grain refining elements) |
- |
1000 |
|
- |
| Cl. 6.1(Aluminium- IS 504 or any other established instrumental/ chemical method) |
- |
1000 |
|
- |
| 9.1(Marking) |
- |
500 |
|
- |
| 14(Workmanship & Finish) |
- |
0 |
|
- |
| 7.1(Dimensions) |
- |
0 |
|
- |
| 6.2(Mechanical properties) |
- |
0 |
|
- |
| 6.3(Drift Expanding Test) |
- |
0 |
|
- |
| 6.4(Drift Expanding Testt) |
- |
0 |
|
- |
| 5.3.2(hydrostatic pressure test) |
- |
0 |
|
- |
| 6.3(Drift expanding test) |
- |
0 |
|
- |
| 7.1 table 2(Dimensions and tolerances for extruded tubes) |
- |
0 |
|
- |
| 6.1(chemical composition) |
- |
0 |
|
- |
| 6.2(ultimate tensile strength) |
- |
0 |
|
- |
| 6.2(0.2% proof strength) |
- |
0 |
|
- |
| 6.2(Elongation on 50 mm gauge length) |
- |
0 |
|
- |
| Cl.4(Workmanship & Finish) |
- |
0 |
|
- |
| Cl.6.2(Ultimate Tensile Strength- IS 2657) |
- |
0 |
|
- |
| Cl.6.2(0.2 percent proof strength- IS 2657) |
- |
0 |
|
- |
| Cl.6.2(Elongation on 50 mm gauge length- IS 2657) |
- |
0 |
|
- |
| Cl. 6.3(Drift Expanding Test ( Expanded Inside Diameter- IS 2335) |
- |
0 |
|
- |
| Cl. 6.4(Hydrostatic Pressure Test-Cl. 6.4) |
- |
0 |
|
- |
| Cl.7.1, Table 2(Outside Diameter-) |
- |
0 |
|
- |
| Cl.7.1, Table 2(Roundness or Ovality) |
- |
0 |
|
- |
| Cl.7.1, Table 2(Wall Thickness) |
- |
0 |
|
- |
| Cl. 7.2(Length) |
- |
0 |
|
- |
| Cl. 6.1(Copper- IS 504 or any other established instrumental/ chemical method) |
- |
0 |
|
- |
| Cl. 6.1(Magnesium- IS 504 or any other established instrumental/ chemical method) |
- |
0 |
|
- |
| Cl. 6.1(Silicon- IS 504 or any other established instrumental/ chemical method) |
- |
0 |
|
- |
| Cl. 6.1(Iron- IS 504 or any other established instrumental/ chemical method) |
- |
0 |
|
- |
| Cl. 6.1(Manganese- IS 504 or any other established instrumental/ chemical method) |
- |
0 |
|
- |
| Cl. 6.1(Zinc- IS 504 or any other established instrumental/ chemical method) |
- |
0 |
|
- |
| Cl. 6.1(Chromium- IS 504 or any other established instrumental/ chemical method) |
- |
0 |
|
- |
| Cl. 6.1(Titanium and/ other grain refining elements) |
- |
0 |
|
- |
| Cl. 6.1(Aluminium- IS 504 or any other established instrumental/ chemical method) |
- |
0 |
|
- |
| 9.1(Marking) |
- |
0 |
|
- |
| 14(Workmanship & Finish) |
- |
0 |
|
- |
| 7.1(Dimensions) |
- |
0 |
|
- |
| 6.2(Mechanical properties) |
- |
0 |
|
- |
| 6.3(Drift Expanding Test) |
- |
0 |
|
- |
| 6.4(Drift Expanding Testt) |
- |
0 |
|
- |
| 5.3.2(hydrostatic pressure test) |
- |
0 |
|
- |
| 6.3(Drift expanding test) |
- |
0 |
|
- |
| 7.1 table 2(Dimensions and tolerances for extruded tubes) |
- |
0 |
|
- |
| 6.1(chemical composition) |
- |
0 |
|
- |
| 6.2(ultimate tensile strength) |
- |
0 |
|
- |
| 6.2(0.2% proof strength) |
- |
0 |
|
- |
| 6.2(Elongation on 50 mm gauge length) |
- |
0 |
|
- |
|
30 Mar, 2027 |
- Included w.e.f 07.01.2025 |
| 6877 |
Aaditech Test and Calibration Lab LLP
| 8179926
| IS 3854 (2023) |
Switches for Domestic and Similar Purposes - Specification (Third Revision) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(General Requirements) |
- |
500 |
|
- |
| Cl-5(General notes on tests) |
- |
500 |
|
- |
| Cl-6(Rating) |
- |
500 |
|
- |
| Cl-8(Marking) |
- |
700 |
|
- |
| Cl-9(Checking of dimensions) |
- |
700 |
|
- |
| Cl-10.1, 10.2(Prevention of Access to Live Parts) |
- |
500 |
|
- |
| Cl-10.3(Requirements for Accessible Metal Parts) |
- |
500 |
|
- |
| Cl-10.4(Requirements for Insulation of the Mechanism) |
- |
500 |
|
- |
| Cl. 10.5(Requirements for Insulation of the Mechanism with Respect to the Surrounding Environment) |
- |
500 |
|
- |
| Cl-10.6(Requirements for Switches Operated Indirectly) |
- |
500 |
|
- |
| Cl-10.7(Requirements for Switches with Replaceable Pull Cord) |
- |
500 |
|
- |
| Cl-11(Provision for earthing) |
- |
1000 |
|
- |
| Cl-12(Terminals) |
- |
1000 |
|
- |
| Cl-13(Constructional requirements) |
- |
1500 |
|
- |
| Cl-14(Mechanism) |
- |
1000 |
|
- |
| Cl-15.1(Resistance to Ageing) |
- |
2000 |
|
- |
| Cl-15.2(Protection Provided by Enclosures of Switches) |
- |
1000 |
|
- |
| Cl-15.3(Resistance to Humidity) |
- |
1500 |
|
- |
| Cl-16.1(General) |
- |
500 |
|
- |
| Cl-16.2(Test for Measuring the Insulation Resistance) |
- |
1000 |
|
- |
| Cl-16.3(Electric Strength Test) |
- |
1000 |
|
- |
| Cl-17(Temperature rise) |
- |
1500 |
|
- |
| Cl-18(Making and breaking capacity) |
- |
1000 |
|
- |
| Cl-19(Normal operation) |
- |
1500 |
|
- |
| Cl-20(Mechanical strength) |
- |
1000 |
|
- |
| Cl-21(Resistance to heat) |
- |
1000 |
|
- |
| Cl-22(Screws, current carrying parts and connections) |
- |
1000 |
|
- |
| Cl-23(Creepage distances, clearances and distance through sealing compound) |
- |
700 |
|
- |
| Cl-24.1(Resistance to abnormal heat and fire) |
- |
1500 |
|
- |
| Cl-24.2(Resistance to tracking) |
- |
1500 |
|
- |
| Cl-25(Resistance to rusting) |
- |
1000 |
|
- |
| 19.1(Test for Switches Intended for Inductive Loads) |
- |
1000 |
|
- |
| 19.2(Test for Switches Intended for Externally Ballasted Lamp Loads) |
- |
1000 |
|
- |
| 19.3(Test for Switches Intended for Self-ballasted Lamp Loads) |
- |
1000 |
|
- |
| 13.5(Attachment of knobs) |
- |
1500 |
|
- |
| 12.3.11(Table 11)(Test Current for the Verification of Electrical and Thermal Stresses in Normal Use of Screwless Terminals) |
- |
1000 |
|
- |
| 12.3.12(Table 13)(Deflection Test Forces) |
- |
1000 |
|
- |
| Cl-7(Classification) |
- |
500 |
|
- |
| Cl-4(General Requirements) |
- |
500 |
|
- |
| Cl-5(General notes on tests) |
- |
0 |
|
- |
| Cl-6(Rating) |
- |
500 |
|
- |
| Cl-8(Marking) |
- |
700 |
|
- |
| Cl-9(Checking of dimensions) |
- |
700 |
|
- |
| Cl-10.1, 10.2(Prevention of Access to Live Parts) |
- |
500 |
|
- |
| Cl-10.3(Requirements for Accessible Metal Parts) |
- |
500 |
|
- |
| Cl-10.4(Requirements for Insulation of the Mechanism) |
- |
500 |
|
- |
| Cl. 10.5(Requirements for Insulation of the Mechanism with Respect to the Surrounding Environment) |
- |
500 |
|
- |
| Cl-10.6(Requirements for Switches Operated Indirectly) |
- |
500 |
|
- |
| Cl-10.7(Requirements for Switches with Replaceable Pull Cord) |
- |
500 |
|
- |
| Cl-11(Provision for earthing) |
- |
1000 |
|
- |
| Cl-12(Terminals) |
- |
1000 |
|
- |
| Cl-13(Constructional requirements) |
- |
1500 |
|
- |
| Cl-14(Mechanism) |
- |
1000 |
|
- |
| Cl-15.1(Resistance to Ageing) |
- |
2000 |
|
- |
| Cl-15.2(Protection Provided by Enclosures of Switches) |
- |
1000 |
|
- |
| Cl-15.3(Resistance to Humidity) |
- |
1500 |
|
- |
| Cl-16.1(General) |
- |
500 |
|
- |
| Cl-16.2(Test for Measuring the Insulation Resistance) |
- |
1000 |
|
- |
| Cl-16.3(Electric Strength Test) |
- |
1000 |
|
- |
| Cl-17(Temperature rise) |
- |
1500 |
|
- |
| Cl-18(Making and breaking capacity) |
- |
1000 |
|
- |
| Cl-19(Normal operation) |
- |
1500 |
|
- |
| Cl-20(Mechanical strength) |
- |
1000 |
|
- |
| Cl-21(Resistance to heat) |
- |
1000 |
|
- |
| Cl-22(Screws, current carrying parts and connections) |
- |
1000 |
|
- |
| Cl-23(Creepage distances, clearances and distance through sealing compound) |
- |
700 |
|
- |
| Cl-24.1(Resistance to abnormal heat and fire) |
- |
1500 |
|
- |
| Cl-24.2(Resistance to tracking) |
- |
1500 |
|
- |
| Cl-25(Resistance to rusting) |
- |
1000 |
|
- |
| 19.1(Test for Switches Intended for Inductive Loads) |
- |
1000 |
|
- |
| 19.2(Test for Switches Intended for Externally Ballasted Lamp Loads) |
- |
1000 |
|
- |
| 19.3(Test for Switches Intended for Self-ballasted Lamp Loads) |
- |
1000 |
|
- |
| 13.5(Attachment of knobs) |
- |
1500 |
|
- |
| 12.3.11(Table 11)(Test Current for the Verification of Electrical and Thermal Stresses in Normal Use of Screwless Terminals) |
- |
1000 |
|
- |
| 12.3.12(Table 13)(Deflection Test Forces) |
- |
1000 |
|
- |
| Cl-7(Classification) |
- |
500 |
|
- |
| Cl-4(General Requirements) |
- |
0 |
|
- |
| Cl-5(General notes on tests) |
- |
0 |
|
- |
| Cl-6(Rating) |
- |
0 |
|
- |
| Cl-8(Marking) |
- |
0 |
|
- |
| Cl-9(Checking of dimensions) |
- |
0 |
|
- |
| Cl-10.1, 10.2(Prevention of Access to Live Parts) |
- |
0 |
|
- |
| Cl-10.3(Requirements for Accessible Metal Parts) |
- |
0 |
|
- |
| Cl-10.4(Requirements for Insulation of the Mechanism) |
- |
0 |
|
- |
| Cl. 10.5(Requirements for Insulation of the Mechanism with Respect to the Surrounding Environment) |
- |
0 |
|
- |
| Cl-10.6(Requirements for Switches Operated Indirectly) |
- |
0 |
|
- |
| Cl-10.7(Requirements for Switches with Replaceable Pull Cord) |
- |
0 |
|
- |
| Cl-11(Provision for earthing) |
- |
0 |
|
- |
| Cl-12(Terminals) |
- |
0 |
|
- |
| Cl-13(Constructional requirements) |
- |
0 |
|
- |
| Cl-14(Mechanism) |
- |
0 |
|
- |
| Cl-15.1(Resistance to Ageing) |
- |
0 |
|
- |
| Cl-15.2(Protection Provided by Enclosures of Switches) |
- |
0 |
|
- |
| Cl-15.3(Resistance to Humidity) |
- |
0 |
|
- |
| Cl-16.1(General) |
- |
0 |
|
- |
| Cl-16.2(Test for Measuring the Insulation Resistance) |
- |
0 |
|
- |
| Cl-16.3(Electric Strength Test) |
- |
0 |
|
- |
| Cl-17(Temperature rise) |
- |
0 |
|
- |
| Cl-18(Making and breaking capacity) |
- |
0 |
|
- |
| Cl-19(Normal operation) |
- |
0 |
|
- |
| Cl-20(Mechanical strength) |
- |
0 |
|
- |
| Cl-21(Resistance to heat) |
- |
0 |
|
- |
| Cl-22(Screws, current carrying parts and connections) |
- |
0 |
|
- |
| Cl-23(Creepage distances, clearances and distance through sealing compound) |
- |
0 |
|
- |
| Cl-24.1(Resistance to abnormal heat and fire) |
- |
0 |
|
- |
| Cl-24.2(Resistance to tracking) |
- |
0 |
|
- |
| Cl-25(Resistance to rusting) |
- |
0 |
|
- |
| 19.1(Test for Switches Intended for Inductive Loads) |
- |
0 |
|
- |
| 19.2(Test for Switches Intended for Externally Ballasted Lamp Loads) |
- |
0 |
|
- |
| 19.3(Test for Switches Intended for Self-ballasted Lamp Loads) |
- |
0 |
|
- |
| 13.5(Attachment of knobs) |
- |
0 |
|
- |
| 12.3.11(Table 11)(Test Current for the Verification of Electrical and Thermal Stresses in Normal Use of Screwless Terminals) |
- |
0 |
|
- |
| 12.3.12(Table 13)(Deflection Test Forces) |
- |
0 |
|
- |
| Cl-7(Classification) |
- |
0 |
|
- |
| Cl-4(General Requirements) |
- |
0 |
|
- |
| Cl-5(General notes on tests) |
- |
0 |
|
- |
| Cl-6(Rating) |
- |
0 |
|
- |
| Cl-8(Marking) |
- |
0 |
|
- |
| Cl-9(Checking of dimensions) |
- |
0 |
|
- |
| Cl-10.1, 10.2(Prevention of Access to Live Parts) |
- |
0 |
|
- |
| Cl-10.3(Requirements for Accessible Metal Parts) |
- |
0 |
|
- |
| Cl-10.4(Requirements for Insulation of the Mechanism) |
- |
0 |
|
- |
| Cl. 10.5(Requirements for Insulation of the Mechanism with Respect to the Surrounding Environment) |
- |
0 |
|
- |
| Cl-10.6(Requirements for Switches Operated Indirectly) |
- |
0 |
|
- |
| Cl-10.7(Requirements for Switches with Replaceable Pull Cord) |
- |
0 |
|
- |
| Cl-11(Provision for earthing) |
- |
0 |
|
- |
| Cl-12(Terminals) |
- |
0 |
|
- |
| Cl-13(Constructional requirements) |
- |
0 |
|
- |
| Cl-14(Mechanism) |
- |
0 |
|
- |
| Cl-15.1(Resistance to Ageing) |
- |
0 |
|
- |
| Cl-15.2(Protection Provided by Enclosures of Switches) |
- |
0 |
|
- |
| Cl-15.3(Resistance to Humidity) |
- |
0 |
|
- |
| Cl-16.1(General) |
- |
0 |
|
- |
| Cl-16.2(Test for Measuring the Insulation Resistance) |
- |
0 |
|
- |
| Cl-16.3(Electric Strength Test) |
- |
0 |
|
- |
| Cl-17(Temperature rise) |
- |
0 |
|
- |
| Cl-18(Making and breaking capacity) |
- |
0 |
|
- |
| Cl-19(Normal operation) |
- |
0 |
|
- |
| Cl-20(Mechanical strength) |
- |
0 |
|
- |
| Cl-21(Resistance to heat) |
- |
0 |
|
- |
| Cl-22(Screws, current carrying parts and connections) |
- |
0 |
|
- |
| Cl-23(Creepage distances, clearances and distance through sealing compound) |
- |
0 |
|
- |
| Cl-24.1(Resistance to abnormal heat and fire) |
- |
0 |
|
- |
| Cl-24.2(Resistance to tracking) |
- |
0 |
|
- |
| Cl-25(Resistance to rusting) |
- |
0 |
|
- |
| 19.1(Test for Switches Intended for Inductive Loads) |
- |
0 |
|
- |
| 19.2(Test for Switches Intended for Externally Ballasted Lamp Loads) |
- |
0 |
|
- |
| 19.3(Test for Switches Intended for Self-ballasted Lamp Loads) |
- |
0 |
|
- |
| 13.5(Attachment of knobs) |
- |
0 |
|
- |
| 12.3.11(Table 11)(Test Current for the Verification of Electrical and Thermal Stresses in Normal Use of Screwless Terminals) |
- |
0 |
|
- |
| 12.3.12(Table 13)(Deflection Test Forces) |
- |
0 |
|
- |
| Cl-7(Classification) |
- |
0 |
|
- |
|
28 Aug, 2027 |
- - |
| 6878 |
SHRI BAJRANG TESTING LABS, GREATER NOIDA
| 8183006
| IS 14333 (2022) |
Polyethylene Pipes for Sewerage and Industrial Chemicals and Effluent � Specification (First Revision) |
all |
59500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2.1,T2("Base Density
(At 27°C Temp.)-IS 7328:2020 ") |
- |
0 |
|
- |
| 5.2.1,T2(Melt Flow Rate (At 190°C /5kg)-IS 2530:1963) |
- |
0 |
|
- |
| 5.2.1,T2(Thermal Stability(Oxidation Induction Time)-IS 4984:2016(Annexure-B)) |
- |
0 |
|
- |
| 5.2.1,T2("Volatile Matter- IS 4984:2016
(Annexure-C)") |
- |
0 |
|
- |
| 5.2.1,T2("Water Content-IS 4984:2016
(Annexure-D)") |
- |
0 |
|
- |
| 5.2.1.1, T2(Compound Density-IS 7328:2020) |
- |
0 |
|
- |
| 5.2.1.1, T2("Compound carbon black -IS 2530:1963
content") |
- |
0 |
|
- |
| 5.2.1.1, T2(Compound Toluene extract - Any Method) |
- |
0 |
|
- |
| 5.2.1.1, T2(Compound maximum volatile matter -IS 4984:2016 (Annexure-C)) |
- |
0 |
|
- |
| 5.2.1.1, T2(Compound carbon black particle size- Any Method) |
- |
0 |
|
- |
| 5.2.1.1, T2(Compound ash content - Any Method) |
- |
0 |
|
- |
| 5.2.1.1, T2("Compound carbon black -IS 2530:1963
dispersion") |
- |
0 |
|
- |
| 5.3(Density of Higher olefin - IS 7328:2020) |
- |
6800 |
|
Total charges of the including Carbon black masterbatch test Rs.-1800 & Carbon Black Powder Rs.-5000 |
| 5.3(Olefin Constituents- 14333-2022) |
- |
0 |
|
- |
| 5.3(Loading of Carbon Black - IS 2530:1963) |
- |
0 |
|
- |
| 5.3(Ash content- Any Method) |
- |
0 |
|
- |
| 5.3(Toluene extract - Any Method) |
- |
0 |
|
- |
| 5.3("Maximum volatile matter -IS 4984:2016
(Annexure-C)") |
- |
0 |
|
- |
| 5.3(Carbon black particle size - Any Method) |
- |
0 |
|
- |
| 5.4(Antioxidant - Any Method) |
- |
0 |
|
- |
| 6(Pipe Description - IS 14333-2022) |
- |
0 |
|
- |
| 6.2(Colour- IS 14333-2022) |
- |
500 |
|
- |
| 7.1(Visual Appearance- IS 14333-2022) |
- |
1000 |
|
Total charges for the all dimension including & Visual Appearance Rs.- 1000/- |
| 7.2(Length- IS 14333-2022) |
- |
0 |
|
- |
| 7.3(Coiling- IS 14333-2022) |
- |
0 |
|
- |
| 7.4,T3 of IS 4984(Outside Diameter-IS 4984-2016) |
- |
0 |
|
- |
| 7.4,T4 of IS 4984(wall Thickness-IS 4984-2016) |
- |
0 |
|
- |
| 7.4,T3 of IS 4984(Ovality-IS 4984-2016) |
- |
0 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 27 oC , Test Period - 100 hrs.-IS 4984-2016 (Annexure-E)) |
- |
5000 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
4000 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 165 hrs.-IS 4984-2016 (Annexure-E)) |
- |
7000 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 1000 hrs.-IS 4984-2016 (Annexure-E)) |
- |
18000 |
|
- |
| 8.1.2, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
0 |
|
- |
| 8.2("Longitudinal Reversion Test - IS 4984-2016
(Annexure-F)") |
- |
2000 |
|
- |
| 8.3(Carbon black content- IS 2530-1963) |
- |
2000 |
|
- |
| 8.3(Carbon black content Dispersion- IS 2530-1963) |
- |
1500 |
|
- |
| 8.4(Melt Flow rate(Temperature - 190oC,Mass 5kg)-IS 2530-1963) |
- |
2000 |
|
- |
| 8.5(Oxidation Induction Time -IS 4984:2016(Annexure-B)) |
- |
4000 |
|
- |
| 8.6(Density-IS 7328:2020) |
- |
1500 |
|
- |
| 8.7("Tensile Strength for Butt Fusion - IS 4984-2016
(Annexure-G)") |
- |
3000 |
|
- |
| 8.8,T5("Tensile - IS 4984-2016
(Annexure-H)") |
- |
2500 |
|
- |
| 8.8,T5("Elongation -IS 4984-2016
(Annexure-H)") |
- |
0 |
|
- |
| 8.9(Slow Crack Growth Rate{Internal Pressure creep Rupture test, Temperature - 80±1 oC , Test Pressure – 0.80MPa, Test Period - 500 hrs.-IS 4984-2016 (Annexure-E &J)) |
- |
9000 |
|
- |
|
01 Dec, 2027 |
- Cl 5.1 Material, 5.2.1 (Dispersion of carbon black content), Cl. 5.3 (a) (Polyethylene), Cl. 5.4 (Anti-oxidant) |
| 6879 |
SHRI BAJRANG TESTING LABS, GREATER NOIDA
| 8183006
| IS 13592 (2013) |
Unplasticized Polyvinyl Chloride (PVC-U) Pipes for Soil and Waste Discharge System Inside and Outside Buiildings Including Ventilation and Rainwater System |
All |
25100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.5(Surface colour of the pipes shall be dark shade of grey) |
- |
500 |
|
- |
| Cl6.3(The composition shall be based on PVC resin
having a K-value of 64 or greater when tested in
accordance with IS 4669) |
- |
2000 |
|
- |
| Cl.7.1(Mean out side Diameter (For less than or equal to 40 mm- Average of 8 , For higher diameters up to 110 mm average of 6)) |
- |
1500 |
|
Total Charges for the all dimension including Rs.-1500/- |
| Cl.7.1(Outside Diameter at any point (Take 8 reading reported minimum, maximum)) |
- |
0 |
|
- |
| Cl.7.1(Wall thickness "minimum,maximum" (Take 8 reading)) |
- |
0 |
|
- |
| Cl.7.2(Pipes shall be supplied in nominal lengths of 2, 3, 4 or
6 metres either plain or with socket for solvent
cementing/grooved socket. Tolerances on specified
length shall be + 10 mm and – 0 mm.The nominal length of the pipe with socket for solvent
cementing/grooved socket shall be as given in Fig. 1.) |
- |
0 |
|
- |
| Cl.7.3.1(Minimum wall thickness of socket on pipes shall
be as given in Table 2 read with Fig. 2 and Fig. 3.) |
- |
0 |
|
- |
| Cl.7.3.2(Dimensions of sockets for solvent cementing and
grooved sockets of pipes shall be as given in Tables 3
and 4 respectively, read with Fig. 2 and 3.) |
- |
0 |
|
- |
| Cl.8.1(The internal and external surface of the pipes shall be
smooth and clean, and free from grooving and other
defects. The end shall be clearly cut and shall be square
with the axis of the pipe. The end may be chamfered
on the plain side.) |
- |
500 |
|
- |
| Cl.8.2(When tested by the method described in IS 12235
(Part 5), a length of pipe sample of 200 ± 20 mm shall
not alter in length by more than 5 percent. In the case
of socket ended pipes, this test shall be carried out on
the plain portion of pipe taken at least 100 mm away
from the root of the socket.) |
- |
2000 |
|
- |
| Cl8.3(This test shall be carried out for socket end pipes only.
When tested by the method described in IS 12235
(Part 6), the test specimens shall not show blisters,
excessive delamination or cracking or signs of weld
line splitting.) |
- |
1500 |
|
- |
| Cl.8.4(When determined in accordance with IS 12235 (Part 2),
the vicat softening temperature of the specimen shall
not be less than 79°C.) |
- |
2000 |
|
- |
| Cl.8.5(After the required
period of exposure, the tensile strengths of two samples when tested as per IS 12235 (Part 13) shall not show
difference of more than 20 percent of their initial tensile
strengths) |
- |
4000 |
|
- |
| Cl. 9, IS 12235 Part 7(Resistance to Sulphuric Acid) |
- |
4000 |
|
- |
| Cl.10.1(When tested by method prescribed in IS 12235 (Part 9),the pipe shall have a true impact rate of not more than
10 percent. Mass of striker and height of fall shall be
as per Annex A.) |
- |
2000 |
|
- |
| Cl.10.2(When determined in accordance with the method
described in IS 12235 (Part 13), the tensile strength at
break shall not be less than 45 MPa.) |
- |
2500 |
|
- |
| Cl.10.3(The axial shrinkage shall not exceed 2 percent when
determined in accordance with Annex B.) |
- |
1500 |
|
- |
| Cl.11.(Jointing of solvent
cementing joints is to be carried out using solvent
conforming to IS 14182.
Apply a pressure of 0.05 MPa for a period of 15 min
and there should be no leakage at any joint.) |
- |
1500 |
|
- |
| Cl. 12, IS 12235 Part 11(Resistance to Di-Chloro-Methane) |
- |
1500 |
|
- |
| 8.6(Effect on Water Test) |
- |
5000 |
|
- |
| 14(Marking) |
- |
0 |
|
- |
|
01 Dec, 2027 |
- - |
| 6880 |
SHRI BAJRANG TESTING LABS, GREATER NOIDA
| 8183006
| IS 14735 (1999) |
Unplasticized Polyvinyl Chloride (UPVC) Injection Moulded Fittings for Soil and Waste Discharge System for Inside and Outside Buildings Including Ventilation and Rain Water System - |
- |
14900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 19(Marking) |
- |
0 |
|
- |
| 3(Type of Fitting) |
- |
0 |
|
- |
| 4(Size Designation) |
- |
0 |
|
- |
| 5(Colour of fittings) |
- |
500 |
|
- |
| 7.1,Table 1(Wall thickness) |
- |
1500 |
|
Total charges for the all dimension including Rs.-1500/- |
| 7.2 ,Table 2&3(Socket Dimensions) |
- |
0 |
|
- |
| 7.3(Dimensions of waste trap(Nahani Trap) |
- |
0 |
|
- |
| 8(Sealing Rings) |
- |
500 |
|
- |
| 10(Workmanship) |
- |
500 |
|
- |
| 11(Design requirements) |
- |
0 |
|
- |
| 11.1(Solvent cement type or Rubber ring type) |
- |
0 |
|
- |
| 11.2(Socket and spigot configeration) |
- |
0 |
|
- |
| 11.4,Table 5(Vent cowl) |
- |
500 |
|
- |
| 11.5,Table 6(Pipe Clips) |
- |
500 |
|
- |
| 12(Physical test requirements) |
- |
0 |
|
- |
| 12.1(Visual appearance) |
- |
500 |
|
- |
| 12.2(Stress relief test) |
- |
1500 |
|
- |
| 12.3(Vicat softening tempewrature) |
- |
2000 |
|
- |
| Cl.13, IS 12235 (P-7)-2004, (Resistance to Sulphuric Acid) |
- |
4000 |
|
- |
| Cl.14, Annex A(Titanium Di-Oxide Content) |
- |
2000 |
|
- |
| Cl.15, Annex B(Sulphated Ash Content) |
- |
1500 |
|
- |
| 16(Mechanical Properties) |
- |
0 |
|
- |
| 16.1(Impact test) |
- |
1500 |
|
- |
| 17(Watet tightness of joint) |
- |
1500 |
|
- |
| 12.4(Effect on water test) |
- |
5000 |
|
- |
| 7.4(Chamfer) |
- |
0 |
|
- |
| 11.3(Access Openings) |
- |
500 |
|
- |
| Table 4(Dimension of Access Openings) |
- |
0 |
|
- |
|
01 Dec, 2027 |
- - |
| 6881 |
SHRI BAJRANG TESTING LABS, GREATER NOIDA
| 8183006
| IS 17546 (2021) |
Chlorinated polyvinyl chloride CPVC fittings for potable hot and cold water distribution supplies Specification |
All |
140000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Nominal Size(DN)) |
- |
1000 |
|
Total charges for the all dimension including Rs.-1000/- |
| 3.2(Nominal Outside Diameter) |
- |
0 |
|
- |
| 3.3(Mean Inside Diameter of Socket at Entry) |
- |
0 |
|
- |
| 3.4(Mean Inside Diameter of Socket at Shoulder (Bottom)) |
- |
0 |
|
- |
| 3.4(Mean Inside Diameter of Socket at Shoulder (Bottom)) |
- |
0 |
|
- |
| 3.5(Out-of-Roundness (Ovality)) |
- |
0 |
|
- |
| 3.6(Nominal Wall Thickness) |
- |
0 |
|
- |
| 3.7(Minimum Wall Thickness) |
- |
0 |
|
- |
| 3.8(Tolerance) |
- |
0 |
|
- |
| 3.9(Working Pressure) |
- |
0 |
|
- |
| 3.1(Standard Dimension Ratio) |
- |
0 |
|
- |
| 3.11(Type Tests) |
- |
0 |
|
- |
| 3.11(Acceptance Tests) |
- |
0 |
|
- |
| 6(Composition) |
- |
35000 |
|
- |
| 7(Dimensions of fitting) |
- |
2000 |
|
- |
| 8.2(Opacity) |
- |
1000 |
|
- |
| 8.1(Visual Appearance) |
- |
500 |
|
- |
| 8.3(Stress Relief Test) |
- |
1500 |
|
- |
| 8.4(Vicat softening Temperature) |
- |
1500 |
|
- |
| 8.5(Density) |
- |
1000 |
|
- |
| 8.6(Effect on water) |
- |
3500 |
|
- |
| 9(Mechanical Properties) |
- |
105000 |
|
- |
| 11(Marking) |
- |
500 |
|
- |
| Cl-6.2.2(Compound Chlorine Content) |
- |
0 |
|
- |
| Cl-6.2.5(Verification of the Malfunction Temperature) |
- |
0 |
|
- |
| Cl-9.1(Hydrostatic Characteristics) |
- |
0 |
|
- |
| Cl-9.2(Thermal Stability by Hydrostatic Pressure Testing) |
- |
0 |
|
- |
|
01 Dec, 2027 |
- - |
| 6882 |
Atmy Analytical Labs Pvt. Ltd., Faridabad
| 8167506
| IS 1171 (2011) |
Ferromanganese - Specification (Fifth Revision) |
- |
14900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause-4(Grades) |
- |
0 |
|
- |
| Clause-6(Supply of Materials) |
- |
0 |
|
- |
| Clause-7.1(Constitution of Consignment) |
- |
0 |
|
- |
| Clause-7, Table-1, S.No-3(Mn) |
- |
0 |
|
- |
| Clause-7.2.1,Table-1, S.No-4(C) |
- |
0 |
|
- |
| Clause-7.2.1, Table-1, S.No-5(Si Max) |
- |
0 |
|
- |
| Clause-7.2.1,Table-1, S.No-6(S Max) |
- |
0 |
|
- |
| Clause-7.2.1,Table-1, S.No-7(P Max) |
- |
0 |
|
- |
| Clause-8(Size Range) |
- |
0 |
|
- |
| Clause-12(Marking) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- - |
| 6883 |
WELL TECH TEST AND RESEARCH CENTER, DERABASSI
| 9177306
| IS 7092 : Part 1 (1992) |
Aluminium alloy tubes for irrigation purposes - Specification: Part 1 welded tubes (Second Revision) |
WELDED TUBES AS PER TABLE 1 |
17000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10(Marking) |
- |
1000 |
|
- |
| 5(Workmanship and Finish) |
- |
1000 |
|
- |
| 8(Dimensions) |
- |
3000 |
|
- |
| 7.2(Mechanical properties) |
- |
5000 |
|
- |
| 7.3(Flattening test) |
- |
3000 |
|
- |
| 7.4(Hydrostatic test) |
- |
4000 |
|
- |
| 10(Marking) |
- |
0 |
|
TEST FACILITY FOR CHEMICAL ANALYSIS IS AVAILABLE AND TESTING CHARGES ARE 3500/- |
| 5(Workmanship and Finish) |
- |
0 |
|
- |
| 8(Dimensions) |
- |
0 |
|
- |
| 7.2(Mechanical properties) |
- |
0 |
|
- |
| 7.3(Flattening test) |
- |
0 |
|
- |
| 7.4(Hydrostatic test) |
- |
0 |
|
- |
|
30 Mar, 2027 |
- Included w.e.f 07.01.2025 |
| 6884 |
SGS India Private Limited-Multilaboratory, Chennai
| 6114716
| IS 14543 (2024) |
Packaged Drinking Water Other than Packaged Natural Mineral Water Specification Third Revision |
- |
15250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.3(Appearance) |
- |
0 |
|
- |
| 5.4/Annex D/i(P,P-DDT) |
- |
0 |
|
- |
| 5.4/Annex D/ii(Lindane) |
- |
0 |
|
- |
| 5.4/Annex D/iv(b-Endosulfan) |
- |
0 |
|
- |
| 5.4/Annex D/xvi(Dieldrin) |
- |
0 |
|
- |
| 5.4/Annex D/xvi(Aldrin) |
- |
0 |
|
- |
| 5.4/Annex D/i(O,P-DDT) |
- |
0 |
|
- |
| 5.4/Annex D/iv(a-Endosulfan) |
- |
0 |
|
- |
| 5.4/Annex D/iii(d-HCH) |
- |
0 |
|
- |
| 5.4/Annex D/i(O,P-DDD) |
- |
0 |
|
- |
| 5.4/Annex D/i(P,P-DDE) |
- |
0 |
|
- |
| 5.4/Annex D/iii(a-HCH) |
- |
0 |
|
- |
| 5.4/Annex D/iii(β- HCH) |
- |
0 |
|
- |
| 5.4/Annex D/iv(Endosulfan sulfate) |
- |
0 |
|
- |
| 5.4/Annex D/i(P,P-DDD) |
- |
0 |
|
- |
| 5.4/Annex D/xii(Alachlor) |
- |
0 |
|
- |
| 5.4/Annex D/vii(Chlorpyrifos) |
- |
0 |
|
- |
| 5.4/Annex D/x(Butachlor) |
- |
0 |
|
- |
| 5.4/Annex D/vi(Ethion) |
- |
0 |
|
- |
| 5.4/Annex D/xiv(Methyl parathion) |
- |
0 |
|
- |
| 5.4/Annex D/xv(Malathion) |
- |
0 |
|
- |
| 5.4/Annex D/viii(Phorate) |
- |
0 |
|
- |
| 5.4/Annex D/v(Monochrotophos) |
- |
0 |
|
- |
| 5.4/Annex D/xiii(Atrazine) |
- |
0 |
|
- |
| 5.4/Annex D/viii(Phorate sulphoxide) |
- |
0 |
|
- |
| 5.4/Annex D/viii(Phorate sulfone) |
- |
0 |
|
- |
| 5.4/Annex D/xxvii(Methyl paraoxon) |
- |
0 |
|
- |
| 5.4/Annex D/xxviii(Malaoxon) |
- |
0 |
|
- |
| 5.4/Annex D/xi(Isoproturon) |
- |
0 |
|
- |
| 5.4/Annex D/ix(2,4 –D) |
- |
0 |
|
- |
| Cl-5.2.1(Escherichia coli or thermotolerant bacteria) |
- |
300 |
|
- |
| Cl-5.2.2(Coliform) |
- |
150 |
|
- |
| Cl-5.2.3(Staphylococcus aureus) |
- |
375 |
|
- |
| Cl-5.2.4(Sulphite Reducing Anaerobes) |
- |
150 |
|
- |
| Cl-5.2.5(Pseudomonas Aeruginosa) |
- |
300 |
|
- |
| Cl-5.2.6(Aerobic Microbial Count @ 37 deg C) |
- |
150 |
|
- |
| Cl-5.2.7(Yeast and mould) |
- |
150 |
|
- |
| Cl-5.2.8(Salmonella) |
- |
675.99 |
|
- |
| Cl-5.2.9(Vibrio cholera) |
- |
450 |
|
- |
| Cl-5.3, Table-1 (i)(Colour, true colour units, Max) |
- |
75 |
|
- |
| Cl-5.3, Table-1 (ii)(Odour) |
- |
37.5 |
|
- |
| Cl-5.3, Table-1 (iii)(Taste) |
- |
37.5 |
|
- |
| Cl-5.3, Table-1 (iv)(Turbidity, nephelometric turbidity unit (NTU), Max) |
- |
37.5 |
|
- |
| Cl-5.3, Table-1 (v)(Total dissolved solids, mg/l, Max) |
- |
75 |
|
- |
| Cl-5.3, Table-1 (vi)(pH) |
- |
37.5 |
|
- |
| Cl-5.3, Table-2 (i)(Barium (as Ba)) |
- |
150 |
|
- |
| Cl-5.3, Table-2 (ii)(Copper (as Cu)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (iii)(Iron (as Fe)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (iv)(Manganese (as Mn)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (v)(Nitrate (as NO3 )) |
- |
300 |
|
- |
| Cl-5.3, Table-2 (vi)(Nitrite (as NO2 )) |
- |
225 |
|
- |
| Cl-5.3, Table-2 (vii)(Fluoride (as F)) |
- |
150 |
|
- |
| Cl-5.3, Table-2 (viii)(Zinc (as Zn)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (ix)(Silver (as Ag)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (x)(Aluminium (as A1)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (xi)(Chloride (as Cl)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (xii)(Selenium (as Se)) |
- |
150 |
|
- |
| Cl-5.3, Table-2 (xiii)(Sulphate (as SO4 )) |
- |
150 |
|
- |
| Cl-5.3, Table-2 (xiv)(Alkalinity (as HCO3 )) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (xv)(Calcium (as Ca)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (xvi)(Magnesium (as Mg)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (xvii)(Sodium (as Na)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (xviii)(Residual free chlorine) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (xix)(Phenolic compounds (as C6H5OH)) |
- |
300 |
|
- |
| Cl-5.3, Table-2 (xx)(Mineral oil) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (xxi)(Anionic surface active agents) |
- |
375 |
|
- |
| Cl-5.3, Table-2 (xxii)(Sulphide) |
- |
150 |
|
- |
| Cl-5.3, Table-2 (xxiii)(Antimony (as Sb)) |
- |
149.99 |
|
- |
| Cl-5.3, Table-2 (xxiv)(Borates (as B)) |
- |
150 |
|
- |
| Cl-5.3, Table-2 (xxv)(Bromates (as BrO3 )) |
- |
2500 |
|
- |
| Cl-5.3, Table-3 (i)(Mercury (as Hg)) |
- |
150 |
|
- |
| Cl-5.3, Table-3 (ii)(Cadmium (as Cd)) |
- |
150 |
|
- |
| Cl-5.3, Table-3 (iii)(Arsenic (as As)) |
- |
150 |
|
- |
| Cl-5.3, Table-3 (iv)(Cyanide (as CN)) |
- |
75 |
|
- |
| Cl-5.3, Table-3 (v)(Lead (as Pb)) |
- |
150 |
|
- |
| Cl-5.3, Table-3 (vi)(Chromium (as Cr)) |
- |
75 |
|
- |
| Cl-5.3, Table-3 (vii)(Nickel (as Ni)) |
- |
75 |
|
- |
| Cl-5.3, Table-3 (viii)(Polychlorinated biphenyl (PCB)) |
- |
300 |
|
- |
| Cl-5.3, Table-3 (ix)(Polynuclear aromatic hydrocarbons) |
- |
450 |
|
- |
| Cl-5.3, Table-3 (x)(Uranium) |
- |
750 |
|
- |
| Cl-5.2.3(Faecal streptococci) |
- |
0 |
|
- |
| Cl-5.2.8(shigella) |
- |
0 |
|
- |
| Cl-5.2.9(V.parahaemolyticus) |
- |
0 |
|
- |
| 5.2.6(Aerobic Microbial Count @ 20 to 22 deg C) |
- |
0 |
|
- |
| 5.4 i)(Dieldrin) |
- |
0 |
|
- |
| 5.4 i)(Aldrin) |
- |
0 |
|
- |
| 5.4 i)(Malathion) |
- |
0 |
|
- |
| 5.4, i)("oxygen analogue of Malathion (Malaoxon)") |
- |
0 |
|
- |
| 5.4 i)(Methyl Paraoxon) |
- |
0 |
|
- |
| 5.4 i)(Methyl Parathion) |
- |
0 |
|
- |
| 5.4 i)(Atrazine) |
- |
0 |
|
- |
| 5.4 i)(Alachlor) |
- |
0 |
|
- |
| 5.4 i)(Isoproturon) |
- |
0 |
|
- |
| 5.4 i)(Butachlor) |
- |
0 |
|
- |
| 5.4 i)(2,4-D) |
- |
0 |
|
- |
| 5.4 i)(Phorate sulphone) |
- |
0 |
|
- |
| 5.4 i)(Phorate sulphoxide) |
- |
0 |
|
- |
| 5.4 i)(Phorate) |
- |
0 |
|
- |
| 5.4 i)(Chlorpyrifos) |
- |
0 |
|
- |
| 5.4 i)(Ethion) |
- |
0 |
|
- |
| 5.4 i)(Monocrotophos) |
- |
0 |
|
- |
| 5.4 i)(Endosulfan Sulphate) |
- |
0 |
|
- |
| 5.4 i)(beta-Endosulfan) |
- |
0 |
|
- |
| 5.4 i)(alpha-Endosulfan) |
- |
0 |
|
- |
| 5.4 i)(Delta-HCH) |
- |
0 |
|
- |
| 5.4 i)(beta-HCH) |
- |
0 |
|
- |
| 5.4 i)(alpha-HCH) |
- |
0 |
|
- |
| 5.4 i)(Gamma-HCH (Lindane)) |
- |
0 |
|
- |
| 5.4 i)(p,p DDD) |
- |
0 |
|
- |
| 5.4 i)(o,p DDD) |
- |
0 |
|
- |
| 5.4 i)(p,p DDE) |
- |
0 |
|
- |
| 5.4, i)(o,p DDE) |
- |
0 |
|
- |
| 5.4 i)(p,p DDT) |
- |
0 |
|
- |
| 5.4 i)(o,p DDT) |
- |
0 |
|
- |
| Table 3, x)(Uranium) |
- |
750 |
|
- |
| Cl-5.1(General Requirements) |
- |
0 |
|
- |
| Cl-5.4 (i)(Pesticide residues considered individually) |
- |
0 |
|
- |
| Cl-5.4 (ii)(Total pesticide residue) |
- |
2775 |
|
- |
| 5.4/Annex D/i(O,P-DDE) |
- |
0 |
|
- |
|
14 Feb, 2028 |
- Included w.e.f 30.04.2025
Exclusion: Cl-5.3, Table-4 (i) (Alpha emitters, Becquerel (Bq/l)), Cl-5.3, Table-4 (ii) (Beta emitters, Becquerel (Bq/l),) |
| 6885 |
Atmy Analytical Labs Pvt. Ltd., Faridabad
| 8167506
| IS 14261 (1995) |
Transmission devices - V - Belts endless narrowv - Belts for industrial use - Specification |
- |
16500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 4(Material And Workmanship) |
- |
0 |
|
- |
| Cl 5.1(Cross-Section Dimensions) |
- |
0 |
|
- |
| Cl 5.2(Cross-Section Dimensions) |
- |
0 |
|
- |
| Cl 6(DESIGNATION) |
- |
0 |
|
- |
| Cl 7(Length Measurement And Tolerances) |
- |
0 |
|
- |
| Cl 7.2.1(Determination of Pitch Length) |
- |
0 |
|
- |
| Cl 7.2.2(Determination of Pitch Length) |
- |
0 |
|
- |
| Cl 7.2.3(Determination of Pitch Length) |
- |
0 |
|
- |
| Cl 7.3(Matched Belts) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- - |
| 6886 |
International Testing Centre, MSME Technology Development Centre, Meerut
| 8177804
| IS 15844 : Part 3 (2024) |
Sports Footwear Part 3 Professional Sports Footwear |
- |
55000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-6(Size and Fittings) |
- |
300 |
|
- |
| Cl-5(Design) |
- |
300 |
|
- |
| Cl-6(Size and Fittings) |
- |
300 |
|
- |
| Cl.7.1.1(Upper to Mid Sole/Out Sole, Upper to Composite Sole (Applicable Only When the Sole is Composite) and Out Sole to Mid Sole (Multilayer, if Present), Bond Performance) |
- |
500 |
|
- |
| Cl.7.1.2(Energy Absorption at Seat Region) |
- |
500 |
|
- |
| Cl.7.1.1(Upper to Mid Sole/Out Sole, Upper to Composite Sole (Applicable Only When the Sole is Composite) and Out Sole to Mid Sole (Multilayer, if Present), Bond Performance) |
- |
300 |
|
- |
| Cl.7.1.2(Energy Absorption at Seat Region) |
- |
500 |
|
- |
| Cl.7.1.3(Complete Shoe Flexing) |
- |
1000 |
|
- |
| Cl.7.1.4(Washability) |
- |
500 |
|
- |
| Cl.7.1.5(Slip Resistance) |
- |
1500 |
|
- |
| Cl.7.1.6(Heel Drop) |
- |
300 |
|
- |
| Cl.7.2 Table-2 S.No- (ii)(Tear strength (average force), N, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (i)("Flexing resistance, Min
a) Dry condition
b) Wet condition") |
- |
1000 |
|
- |
| Cl.7.2 Table-2 S.No- (iii)("Colour fastness rubbing
a-Dry
b-Wet") |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (iv)("a) Water vapour permeability
b) Water vapour coefficient") |
- |
1000 |
|
- |
| Cl.7.2 Table-2 S.No- (v)(Stitch tear strength N/mm, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (vi)(Colour fastness to light grey scale rate) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (vii)(Tensile strength) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (viii)(Elongation at break, percent) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (ix)("Abrasion test
a) Dry
b) Wet") |
- |
1000 |
|
- |
| Cl.7.2 Table-3 S.No- (i)(Breaking strength, N/mm, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (ii)(Elongation at break, percent, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (iii)(Tear strength, N, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (iv)(Strength at needle perforation) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (v)("Flexing resistance
a-Dry condition, b) Wet condition") |
- |
800 |
|
- |
| Cl.7.2 Table-3 S.No- (vi)("a) Water vapour permeability
b) Water vapour coefficient") |
- |
1000 |
|
- |
| Cl.7.2 Table-3 S.No- (vii)(Hydrolysis resistance) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (viii)(Colour fastness to light grey scale rate) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (ix)(Bursting strength) |
- |
500 |
|
- |
| Cl.7.3 Table-4 S.No- (i)(Tear strength, N, Min) |
- |
500 |
|
- |
| Cl.7.3 Table-4 S.No- (ii)("Abrasion resistance,
a) Dry
b) Wet
") |
- |
800 |
|
- |
| Cl.7.3 Table-4 S.No- (iii)(Colour fastness to rubbing, grey scale rate with 10 rubs on dry or wet, Min) |
- |
500 |
|
- |
| Cl.7.3 Table-4 S.No- (iv)(Colour fastness to perspiration (contact method) grey scale rate, Min) |
- |
500 |
|
- |
| Cl.7.3 Table-4 S.No- (v)("a-Water vapour permeability
b-Water vapour coefficient") |
- |
500 |
|
- |
| Cl.7.4 Table-5 S.No- (ii)(Abrasion resistance) |
- |
800 |
|
- |
| Cl.7.4 Table-5 S.No- (iii)("a) Water absorption
b) Water desorption") |
- |
800 |
|
- |
| Cl.7.5 Table-6 S.No- (i)("Abrasion resistance
a) Dry condition
b) Wet condition") |
- |
800 |
|
- |
| Cl.7.5 Table-6 S.No- (ii)("a) Water absorption
b) Water desorption") |
- |
1000 |
|
- |
| Cl.7.5 Table-6 S.No- (iii)(Heat resistance shrinkage linear, percent, Max) |
- |
500 |
|
- |
| Cl.7.6 Table-7 S.No- (i)(Abrasion resistance) |
- |
500 |
|
- |
| Cl.7.6 Table-7 S.No- (ii)("Flexing resistance
a) Bennewart Method
b) Ross flexing method") |
- |
1000 |
|
- |
| Cl.7.6 Table-7 S.No- (iii)(Hydrolysis resistance) |
- |
2000 |
|
- |
| Cl.7.6 Table-7 S.No- (iv)(Tear strength, N/mm, Min) |
- |
500 |
|
- |
| Cl.7.6 Table-7 S.No- (v)(Tensile strength) |
- |
500 |
|
- |
| Cl.7.6 Table-7 S.No- (vi)(Elongation at break percent, Min) |
- |
500 |
|
- |
| Cl.7.6 Table-7 S.No- (vii)(Compression set percent, Max) |
- |
800 |
|
- |
| Cl.7.7 Table-8 S.No- (i)("Compression set, percent, Max
a) For EVA
b) For all other material") |
- |
800 |
|
- |
| Cl.7.7 Table-8 S.No- (ii)(Split tear strength) |
- |
500 |
|
- |
| Cl.7.7 Table-8 S.No- (iii)(Heat shrinkage, percent, Ma) |
- |
1000 |
|
- |
| Cl.7.7 Table-8 S.No- (iv)(Elongation at break, percent, Min) |
- |
500 |
|
- |
| Cl.7.8 Table-9 S.No- (i)(First dry collapsing load, hardness, N, Min) |
- |
1000 |
|
- |
| Cl.7.8 Table-9 S.No- (ii)(Resilience, percent, Min) |
- |
500 |
|
- |
| Cl.7.8 Table-9 S.No- (iii)(Moisture resistance, percent, Min) |
- |
1700 |
|
- |
| Cl.7.8 Table-9 S.No- (v)(Peel strength, N/nm, Min) |
- |
500 |
|
- |
| Cl.7.9 Table-10 S.No- (i)("Peel strength, N/mm, Min
a) Initial
b) After 5 000 wear cycles") |
- |
500 |
|
- |
| Cl.7.9 Table-10 S.No- (ii)("Shear strength, kPa, Min
a) Initial
b) After 5 000 wear cycles") |
- |
500 |
|
- |
| Cl.7.10 Table-11 S.No- (i)(Limit of useful extension, percent, Min) |
- |
500 |
|
- |
| Cl.7.10 Table-11 S.No- (ii)(Needle strength, N/mm, Min) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (i)(Breaking strength of lace) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (ii)(Lace tag strength) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (iii)(Lace to lace abrasion) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (iv)(Colour fastness to water (for lace) (Contact method)) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (v)(Strength of buckle/ski hook/D-ring,) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (vi)("Corrosion resistance (applicable for all including decorative metal part)
") |
- |
500 |
|
- |
| Cl.7.11 Table-13 S.No- (i)(Corrosion resistance (applicable for metallic spikes)) |
- |
500 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(i)(Allergenic and carcinogenic disperse dyes) |
- |
3000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
3000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
3000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(iv)(Chromium (VI)) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(v)(Dimethyl fumarate (DMFU)) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(vii)(Formaldehyde) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(viii)(Organotin compounds) |
- |
4500 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
3000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(viii)(Organotin compounds) |
- |
4500 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(v)(Dimethyl fumarate (DMFU)) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(iv)(Chromium (VI)) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(x)(pH) |
- |
500 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(xi)(Phthalates (each individual phthalate)) |
- |
4500 |
|
- |
| C-7.12.1, Table no. 1 of IS 17011,(xii)(Nickel, on skin contact 2-(thiocyanomethylthio) -benzothiazole (TCMTB)) |
- |
1000 |
|
- |
| Cl-7.12.2(PVC is present in sports shoe) |
- |
2000 |
|
- |
| Cl- 8.1(Marking) |
- |
300 |
|
- |
| Cl.7.7 Table-8 S.No- (iii)(Elongation at break, percent, Min) |
- |
500 |
|
- |
| Cl.7.8 Table-9 S.No- (iv)("a) Initial dry area shape retention, percent, Min
b) Area shape retention after 10th
collapse, dry, percent, Min
") |
- |
500 |
|
- |
| Cl-6(Size and Fittings) |
- |
300 |
|
- |
| Cl-5(Design) |
- |
300 |
|
- |
| Cl-6(Size and Fittings) |
- |
300 |
|
- |
| Cl.7.1.1(Upper to Mid Sole/Out Sole, Upper to Composite Sole (Applicable Only When the Sole is Composite) and Out Sole to Mid Sole (Multilayer, if Present), Bond Performance) |
- |
500 |
|
- |
| Cl.7.1.2(Energy Absorption at Seat Region) |
- |
500 |
|
- |
| Cl.7.1.1(Upper to Mid Sole/Out Sole, Upper to Composite Sole (Applicable Only When the Sole is Composite) and Out Sole to Mid Sole (Multilayer, if Present), Bond Performance) |
- |
500 |
|
- |
| Cl.7.1.2(Energy Absorption at Seat Region) |
- |
500 |
|
- |
| Cl.7.1.3(Complete Shoe Flexing) |
- |
1500 |
|
- |
| Cl.7.1.4(Washability) |
- |
1000 |
|
- |
| Cl.7.1.5(Slip Resistance) |
- |
1500 |
|
- |
| Cl.7.1.6(Heel Drop) |
- |
300 |
|
- |
| Cl.7.2 Table-2 S.No- (ii)(Tear strength (average force), N, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (i)("Flexing resistance, Min
a) Dry condition
b) Wet condition") |
- |
1500 |
|
- |
| Cl.7.2 Table-2 S.No- (iii)("Colour fastness rubbing
a-Dry
b-Wet") |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (iv)("a) Water vapour permeability
b) Water vapour coefficient") |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (v)(Stitch tear strength N/mm, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (vi)(Colour fastness to light grey scale rate) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (vii)(Tensile strength) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (viii)(Elongation at break, percent) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (ix)("Abrasion test
a) Dry
b) Wet") |
- |
800 |
|
- |
| Cl.7.2 Table-3 S.No- (i)(Breaking strength, N/mm, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (ii)(Elongation at break, percent, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (iii)(Tear strength, N, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (iv)(Strength at needle perforation) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (v)("Flexing resistance
a-Dry condition, b) Wet condition") |
- |
800 |
|
- |
| Cl.7.2 Table-3 S.No- (vi)("a) Water vapour permeability
b) Water vapour coefficient") |
- |
800 |
|
- |
| Cl.7.2 Table-3 S.No- (vii)(Hydrolysis resistance) |
- |
1500 |
|
- |
| Cl.7.2 Table-3 S.No- (viii)(Colour fastness to light grey scale rate) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (ix)(Bursting strength) |
- |
500 |
|
- |
| Cl.7.3 Table-4 S.No- (i)(Tear strength, N, Min) |
- |
500 |
|
- |
| Cl.7.3 Table-4 S.No- (ii)("Abrasion resistance,
a) Dry
b) Wet
") |
- |
800 |
|
- |
| Cl.7.3 Table-4 S.No- (iii)(Colour fastness to rubbing, grey scale rate with 10 rubs on dry or wet, Min) |
- |
500 |
|
- |
| Cl.7.3 Table-4 S.No- (iv)(Colour fastness to perspiration (contact method) grey scale rate, Min) |
- |
500 |
|
- |
| Cl.7.3 Table-4 S.No- (v)("a-Water vapour permeability
b-Water vapour coefficient") |
- |
500 |
|
- |
| Cl.7.4 Table-5 S.No- (ii)(Abrasion resistance) |
- |
800 |
|
- |
| Cl.7.4 Table-5 S.No- (iii)("a) Water absorption
b) Water desorption") |
- |
500 |
|
- |
| Cl.7.5 Table-6 S.No- (i)("Abrasion resistance
a) Dry condition
b) Wet condition") |
- |
500 |
|
- |
| Cl.7.5 Table-6 S.No- (ii)("a) Water absorption
b) Water desorption") |
- |
500 |
|
- |
| Cl.7.5 Table-6 S.No- (iii)(Heat resistance shrinkage linear, percent, Max) |
- |
800 |
|
- |
| Cl.7.6 Table-7 S.No- (i)(Abrasion resistance) |
- |
800 |
|
- |
| Cl.7.6 Table-7 S.No- (ii)("Flexing resistance
a) Bennewart Method
b) Ross flexing method") |
- |
1500 |
|
- |
| Cl.7.6 Table-7 S.No- (iii)(Hydrolysis resistance) |
- |
1500 |
|
- |
| Cl.7.6 Table-7 S.No- (iv)(Tear strength, N/mm, Min) |
- |
500 |
|
- |
| Cl.7.6 Table-7 S.No- (v)(Tensile strength) |
- |
500 |
|
- |
| Cl.7.6 Table-7 S.No- (vi)(Elongation at break percent, Min) |
- |
500 |
|
- |
| Cl.7.6 Table-7 S.No- (vii)(Compression set percent, Max) |
- |
800 |
|
- |
| Cl.7.7 Table-8 S.No- (i)("Compression set, percent, Max
a) For EVA
b) For all other material") |
- |
800 |
|
- |
| Cl.7.7 Table-8 S.No- (ii)(Split tear strength) |
- |
500 |
|
- |
| Cl.7.7 Table-8 S.No- (iii)(Heat shrinkage, percent, Ma) |
- |
500 |
|
- |
| Cl.7.7 Table-8 S.No- (iv)(Elongation at break, percent, Min) |
- |
500 |
|
- |
| Cl.7.8 Table-9 S.No- (i)(First dry collapsing load, hardness, N, Min) |
- |
500 |
|
- |
| Cl.7.8 Table-9 S.No- (ii)(Resilience, percent, Min) |
- |
500 |
|
- |
| Cl.7.8 Table-9 S.No- (iii)(Moisture resistance, percent, Min) |
- |
500 |
|
- |
| Cl.7.8 Table-9 S.No- (v)(Peel strength, N/nm, Min) |
- |
500 |
|
- |
| Cl.7.9 Table-10 S.No- (i)("Peel strength, N/mm, Min
a) Initial
b) After 5 000 wear cycles") |
- |
500 |
|
- |
| Cl.7.9 Table-10 S.No- (ii)("Shear strength, kPa, Min
a) Initial
b) After 5 000 wear cycles") |
- |
500 |
|
- |
| Cl.7.10 Table-11 S.No- (i)(Limit of useful extension, percent, Min) |
- |
500 |
|
- |
| Cl.7.10 Table-11 S.No- (ii)(Needle strength, N/mm, Min) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (i)(Breaking strength of lace) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (ii)(Lace tag strength) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (iii)(Lace to lace abrasion) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (iv)(Colour fastness to water (for lace) (Contact method)) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (v)(Strength of buckle/ski hook/D-ring,) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (vi)("Corrosion resistance (applicable for all including decorative metal part)
") |
- |
500 |
|
- |
| Cl.7.11 Table-13 S.No- (i)(Corrosion resistance (applicable for metallic spikes)) |
- |
500 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(i)(Allergenic and carcinogenic disperse dyes) |
- |
3000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
3500 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
3500 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(iv)(Chromium (VI)) |
- |
1000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(v)(Dimethyl fumarate (DMFU)) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
1000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(vii)(Formaldehyde) |
- |
1000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(viii)(Organotin compounds) |
- |
3500 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
3000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(viii)(Organotin compounds) |
- |
3000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(v)(Dimethyl fumarate (DMFU)) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(iv)(Chromium (VI)) |
- |
1000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(x)(pH) |
- |
500 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(xi)(Phthalates (each individual phthalate)) |
- |
4500 |
|
- |
| C-7.12.1, Table no. 1 of IS 17011,(xii)(Nickel, on skin contact 2-(thiocyanomethylthio) -benzothiazole (TCMTB)) |
- |
1000 |
|
- |
| Cl-7.12.2(PVC is present in sports shoe) |
- |
500 |
|
- |
| Cl- 8.1(Marking) |
- |
300 |
|
- |
| Cl.7.7 Table-8 S.No- (iii)(Elongation at break, percent, Min) |
- |
500 |
|
- |
| Cl.7.8 Table-9 S.No- (iv)("a) Initial dry area shape retention, percent, Min
b) Area shape retention after 10th
collapse, dry, percent, Min
") |
- |
500 |
|
- |
| Cl.7.4 Table-5 S.No- (i)(Flexing index, Min) |
- |
1500 |
|
- |
|
15 Apr, 2027 |
- Included w.e.f.29.11.2024 |
| 6887 |
NATIONAL TESTING BUREAU, GHAZIABAD
| 8186826
| IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
Electrical appliances for heating Liquids |
18000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
100 |
|
- |
| 7(Marking and instructions) |
- |
100 |
|
- |
| 8(Protection against live parts) |
- |
200 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
200 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
400 |
|
- |
| 11(HEATING) |
- |
500 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
500 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
1000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
1500 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
500 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
2000 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
300 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
300 |
|
- |
| 22(CONSTRUCTION) |
- |
1500 |
|
- |
| 23(INTERNAL WIRING) |
- |
500 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
500 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
500 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
300 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
300 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
200 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
1000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
100 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1000 |
|
- |
| 18(ENDURANCE) |
- |
1500 |
|
- |
| 22.16(Automatic cord reel) |
- |
1000 |
|
- |
| 22.32(Oxygen bomb for rubber material) |
- |
100 |
|
- |
| 22.47(Water pressure inlet) |
- |
200 |
|
- |
| 22.106(Interlocks) |
- |
200 |
|
- |
| 22.3(Flexing test) |
- |
500 |
|
- |
| 24(COMPONENTS) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
500 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
500 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
500 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
500 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
500 |
|
- |
| 19.11.4.7(Harmonics) |
- |
500 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-2-15) |
- |
2000 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
2000 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
2000 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
2000 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
100 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
100 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.9(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.1O(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.12(Marking- IS 302-2-15) |
- |
100 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.12.1(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.12.3(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.12.5(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.12.6(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
100 |
|
- |
| 7.101(Marking- IS 302-2-15) |
- |
100 |
|
- |
| 4(General requirements) |
- |
100 |
|
- |
| 5(General Conditions of tests) |
- |
100 |
|
- |
| 6(Classification- IS 302-1) |
- |
100 |
|
- |
| 6(Classification- IS 302-1) |
- |
100 |
|
- |
| 6(Classification- IS 302-1) |
- |
100 |
|
- |
| 6(Classification- IS 302-1) |
- |
100 |
|
- |
| 8(Protection Against Electric Shock, IS 302-1) |
- |
200 |
|
- |
| Marking- IS 302-1(Marking- IS 302-1) |
- |
100 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
400 |
|
- |
| 11(Heating, IS 302-1) |
- |
500 |
|
- |
| 11(Heating, IS 302-1) |
- |
500 |
|
- |
| 11(Heating, IS 302-1) |
- |
500 |
|
- |
| 11(Heating, IS 302-1) |
- |
500 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
500 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
1500 |
|
- |
| 15.2(Spillage test as 15.2, IS 3.02-1 & 302-2-15) |
- |
500 |
|
- |
| 16(Leakage current as per Cl 16, IS 302-1) |
- |
500 |
|
- |
| 16(electric strength as per Cl 16, IS 302-1) |
- |
500 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
2000 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
300 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
300 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
300 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
1500 |
|
- |
| 22.7(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
1500 |
|
- |
| 22.107(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
1500 |
|
- |
| 22.108(Construction as per Cl 22.8, IS 3.02-2-15) |
- |
1500 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.1O(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1500 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
500 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
500 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
300 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
300 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
300 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
300 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
300 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
200 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
200 |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
1000 |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
1000 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
1000 |
|
- |
|
10 Jul, 2028 |
- Exclusion: Cl 19.11.4.1-19.11.4.7 (EMI/EMC) |
| 6888 |
Stellar Test House, Noida
| 8171606
| IS 302 : Part 2 : Sec 202 (1992) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 202 electric stoves |
- |
14000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
50 |
|
5% Discount for BIS |
| 6(Classification- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.3(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.4(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.6(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.11(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.12(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.13(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.14(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.15(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.101(Marking) |
- |
50 |
|
5% Discount for BIS |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
400 |
|
5% Discount for BIS |
| 10(Power Input and Current, IS 302-1) |
- |
800 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
200 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 12(Operation under overload conditions of appliances with heating elements, IS 302-2-202: 1992) |
- |
100 |
|
5% Discount for BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 15.1(Moisture Resistance, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 15.3(Moisture Resistance, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.2(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.2(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.3(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.3(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 21.1(Mechanical Strength, IS 302-1 & IS 302-2-202) |
- |
500 |
|
5% Discount for BIS |
| 22(Construction, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 22.101(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.102(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.103(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.104(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.105(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.105.1(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.105.2(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.106(Construction) |
- |
100 |
|
5% Discount for BIS |
| 11.107.1(Construction) |
- |
100 |
|
5% Discount for BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.2(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.8(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.9(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.10(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 24.1(Components, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 24.2(Components, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 24.101(Components) |
- |
100 |
|
5% Discount for BIS |
| 22.107(Construction) |
- |
100 |
|
5% Discount for BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.4(Supply Connection and External Flexible Cords) |
- |
50 |
|
5% Discount for BIS |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 27.1(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.2(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.3(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.4(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.5(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 28(Screws & Connections, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 6(Classification- IS 302-1 ) |
- |
50 |
|
5% Discount for BIS |
| 6(Classification- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.3(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.4(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.6(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.11(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.12(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.13(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.14(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.15(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.101(Marking) |
- |
50 |
|
5% Discount for BIS |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
400 |
|
5% Discount for BIS |
| 10(Power Input and Current, IS 302-1) |
- |
800 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
200 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 12(Operation under overload conditions of appliances with heating elements, IS 302-2-202: 1992) |
- |
100 |
|
5% Discount for BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 15.1(Moisture Resistance, IS 302-1) |
- |
1000 |
|
5% Discount for BIS |
| 15.3(Moisture Resistance, IS 302-1) |
- |
1000 |
|
5% Discount for BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.2(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.2(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.3(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.3(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 21.1(Mechanical Strength, IS 302-1 & IS 302-2-202) |
- |
500 |
|
5% Discount for BIS |
| 22(Construction, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 22.101(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.102(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.103(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.104(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.105(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.105.1(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.105.2(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.106(Construction) |
- |
100 |
|
5% Discount for BIS |
| 11.107.1(Construction) |
- |
100 |
|
5% Discount for BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.2(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.8(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.9(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.10(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 24.1(Components, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 24.2(Components, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 24.101(Components) |
- |
100 |
|
5% Discount for BIS |
| 22.107(Construction) |
- |
100 |
|
5% Discount for BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.4(Supply Connection and External Flexible Cords) |
- |
50 |
|
5% Discount for BIS |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 27.1(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.2(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.3(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.4(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.5(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 28(Screws & Connections, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 6(Classification- IS 302-1 ) |
- |
50 |
|
5% Discount for BIS |
| 6(Classification- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.3(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.4(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.6(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.11(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.12(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.13(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.14(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.15(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.101(Marking) |
- |
50 |
|
5% Discount for BIS |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
400 |
|
5% Discount for BIS |
| 10(Power Input and Current, IS 302-1) |
- |
800 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 12(Operation under overload conditions of appliances with heating elements, IS 302-2-202: 1992) |
- |
100 |
|
5% Discount for BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 15.1(Moisture Resistance, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 15.3(Moisture Resistance, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.2(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.2(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.3(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.3(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 21.1(Mechanical Strength, IS 302-1 & IS 302-2-202) |
- |
500 |
|
5% Discount for BIS |
| 22(Construction, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 22.101(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.102(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.103(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.104(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.105(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.105.1(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.105.2(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.106(Construction) |
- |
100 |
|
5% Discount for BIS |
| 11.107.1(Construction) |
- |
100 |
|
5% Discount for BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.2(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.8(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.9(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.10(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 24.1(Components, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 24.2(Components, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 24.101(Components) |
- |
100 |
|
5% Discount for BIS |
| 22.107(Construction) |
- |
100 |
|
5% Discount for BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.4(Supply Connection and External Flexible Cords) |
- |
50 |
|
5% Discount for BIS |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 27.1(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.2(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.3(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.4(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.5(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 28(Screws & Connections, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
|
26 Sep, 2028 |
- Included w.e.f.12.12.2024
Exclusion
Cl 24, CL 22, (EMI/EMC)
19.11.4.1 to 19.11.4.7 |
| 6889 |
IDMA LABORATORIES LIMITED, PANCHKULA
| 9123236
| IS 10631 (1983) |
Specification for stainless steel for welding electrode core wire |
- |
21000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1 Table 1(Carbon- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
2000 |
|
- |
| 5.1 Table 1(Silicon- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
2000 |
|
- |
| 5.1 Table 1(Manganese- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
2000 |
|
- |
| 5.1 Table 1(Chromium- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
2000 |
|
- |
| 5.1 Table 1(Nickel- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
2000 |
|
- |
| 5.1 Table 1(Molybdenum- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
2000 |
|
- |
| 5.1 Table 1(Sulphur- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
2000 |
|
- |
| 5.1 Table 1(Phosphorous- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
2000 |
|
- |
| 6(FREEDOM FROM DEFECTS) |
- |
2000 |
|
- |
| 7(Size and Tolerances) |
- |
3000 |
|
- |
| Clause 5.1(Molybdenum) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Nickel) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Chromium) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Silicon) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Phosphorous) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Sulphur) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Manganese) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Carbon) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Carbon- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Silicon- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Manganese- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Chromium- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Nickel- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Molybdenum- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Sulphur- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Phosphorous- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 6(FREEDOM FROM DEFECTS) |
- |
0 |
|
(Repeat entry) |
| 7(Size and Tolerances) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Molybdenum) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Nickel) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Chromium) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Silicon) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Phosphorous) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Sulphur) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Manganese) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Carbon) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Carbon- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Silicon- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Manganese- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Chromium- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Nickel- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Molybdenum- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Sulphur- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Phosphorous- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 6(FREEDOM FROM DEFECTS) |
- |
0 |
|
(Repeat entry) |
| 7(Size and Tolerances) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Molybdenum) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Nickel) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Chromium) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Silicon) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Phosphorous) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Sulphur) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Manganese) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Carbon) |
- |
0 |
|
(Repeat entry) |
|
31 Dec, 2026 |
- Included w.e.f.21.11.2024 |
| 6890 |
International Testing Centre, MSME Technology Development Centre, Meerut
| 8177804
| IS 17012 (2018) |
High ankle tactical boots with pu - Rubber sole - Specification |
- |
38600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.0(Innocuousness Test IS 17011) |
- |
20000 |
|
- |
| 4.16.2(Breaking Strength of lace ) |
- |
500 |
|
- |
| 4.16.1(Length of lace ) |
- |
300 |
|
- |
| 4.15(D-ring & Hooks ) |
- |
300 |
|
- |
| 6.1(Resistance to Fuel Oil) |
- |
500 |
|
- |
| 4.14.9(Resistance to hot contact ) |
- |
500 |
|
- |
| 4.14.8(Flexing resistance ) |
- |
800 |
|
- |
| 4.14.7(Ageing test) |
- |
1500 |
|
- |
| 4.14.6(Hardness (IRHD)) |
- |
500 |
|
- |
| 4.14.5(Abrasion resistance ) |
- |
800 |
|
- |
| 4.14.4(Tear Strength) |
- |
500 |
|
- |
| 4.14.3(Sole Density ) |
- |
300 |
|
- |
| 4.14.2(Thickness) |
- |
300 |
|
- |
| 4.14.1(Material) |
- |
500 |
|
- |
| 4.13(Breaking Strength of thread ) |
- |
500 |
|
- |
| 4.12.2(Tear Strength) |
- |
500 |
|
- |
| 4.12.1(Thickness ) |
- |
300 |
|
- |
| 4.11.2(Tear Strength) |
- |
500 |
|
- |
| 4.11.1(Thickness ) |
- |
300 |
|
- |
| 4.10.3(Water absorption & desorption percent) |
- |
1000 |
|
- |
| 4.10.2(Abrasion resistance ) |
- |
1000 |
|
- |
| 4.10.1(Material) |
- |
500 |
|
- |
| 4.9.3(Water absorption & desorption percent) |
- |
1000 |
|
- |
| 4.9.2(Abrasion resistance ) |
- |
1000 |
|
- |
| 4.9.1(Thickness) |
- |
300 |
|
- |
| 4.8(Thickness Toe puff & counter stiffener) |
- |
1000 |
|
- |
| 4.7.5(Water Vapour permeability & coefficient ) |
- |
1000 |
|
- |
| 4.7.4(Abrasion resistance ) |
- |
800 |
|
- |
| 4.7.3(Tear Strength) |
- |
500 |
|
- |
| 4.7.2(Material Counter & Tongue) |
- |
800 |
|
- |
| 4.7.1(Material vamp & Quarter) |
- |
800 |
|
- |
| 4.6.3(Water Penetration and water absorption ) |
- |
1000 |
|
- |
| 4.6.2(Tear Strength) |
- |
500 |
|
- |
| 4.6.1(Thickness ) |
- |
300 |
|
- |
| 4.5.8(Energy absorption of seat region ) |
- |
500 |
|
- |
| 4.5.7(Cold Insulation of sole complex) |
- |
500 |
|
- |
| 4.5.6(Heat Insulation of sole Complex) |
- |
500 |
|
- |
| 4.5.5(Antistatic test) |
- |
1000 |
|
- |
| 4.5.4(Slip Resitance) |
- |
1500 |
|
- |
| 4.5.3.2(Interayer bond strength) |
- |
500 |
|
- |
| 4.5.3.1(Upper/outsole bond strength) |
- |
500 |
|
- |
| 4.5.2(Ergonomic Feature) |
- |
500 |
|
- |
| 4.5.1(Construction) |
- |
500 |
|
- |
| 4.4(Height of upper ) |
- |
300 |
|
- |
| 4.3.2(Weight) |
- |
300 |
|
- |
| 4.2(Design ) |
- |
300 |
|
- |
| Cl. 6, Cl.6.1, 6.1.1 & 6.1.2, 8.6 of IS 15298 part 1,ISO 1817,ISO 4643,(Resistance to fuel oil) |
- |
1500 |
|
- |
| 8, 8.1, 8.2, 8.2.1(Marking) |
- |
300 |
|
- |
| 9(Information to be Supplied) |
- |
300 |
|
- |
| Cl.4.6.4(Water Penetration and Water Absorption) |
- |
1000 |
|
- |
| Cl. 6, Cl.6.1, 6.1.1 & 6.1.2,(Resistance to fuel oil) |
- |
500 |
|
- |
| CL.8,8.1, 8.2,8.2.1(Marking) |
- |
300 |
|
- |
| Cl.9,(Information to be Supplied) |
- |
300 |
|
- |
| 4.3.1(Size) |
- |
300 |
|
- |
|
15 Apr, 2027 |
- Included w.e.f 19.09.2024 |
| 6891 |
Ahmedabad Textile Industry's Research Association (ATIRA), Ahmedabad
| 7173002
| IS 16089 (2013) |
Jute agro-textile – Sapling bags for growth of seedling/ sapling – Specification |
- |
3250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4, Table 1, (i)(Mass, g/m², Min) |
- |
450 |
|
- |
| Clause 4, Table 1, (ii)(Thickness, mm) |
- |
450 |
|
- |
| Clause 4, Table 1, (iv) a(Threads/dm, Warp) |
- |
150 |
|
- |
| Clause 4, Table 1, (iv) b(Threads/dm, Weft) |
- |
150 |
|
- |
| Clause 4, Table 1, (v)(Width of Hessian fabric, cm) |
- |
200 |
|
- |
| Clause 4, Table 1, (vi)(Length and width of sapling bags, cm, Min) |
- |
400 |
|
- |
| Clause 4, Table 1, (vii)(Water holding capacity, percent) |
- |
550 |
|
- |
| Clause 4, Table 1, (viii) a(Tensile strength, kN/m, Warp) |
- |
450 |
|
- |
| Clause 4, Table 1, (viii) b(Tensile strength, kN/m, Weft) |
- |
450 |
|
- |
|
- |
- Included w.e.f 10.10.2024
Excluding Cl 4, Table 1, (iii) (Open area, percent) |
| 6892 |
Alpha Test House Services LLP (160), Sahibzada Ajit Singh Nagar
| 9138706
| IS 2501 (1995) |
Solid drawn copper tubesfor general engineering purposes - Specification (Third Revision) |
Copper tubes |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. No.5(Grades) |
- |
6000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No.6(CONDITION) |
- |
100 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 7(FREEDOM FROM DEFECTS) |
- |
100 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 8.1(Dimensions) |
- |
1500 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 8.2(Tolerances) |
- |
200 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 9(CHEMICAL COMPOSITION) |
- |
6000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 10.1.1, Table no. 1(Tensile Test) |
- |
2500 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 10.2(Flattening and Doubling-Over Test) |
- |
1900 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 10.3(Drift Expanding Test) |
- |
2000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 10.4(Non-Destructive Testing) |
- |
100 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 10.5("Microscopic Examination ( for 0 Condition
Only )") |
- |
500 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 13(Marking) |
- |
100 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| 10.6(Hydrogen Embrittlement Test) |
- |
0 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No.5(Grades) |
- |
6000 |
|
- |
| Cl. No.6(CONDITION) |
- |
100 |
|
- |
| Cl. No. 7(FREEDOM FROM DEFECTS) |
- |
100 |
|
- |
| Cl. No. 8.1(Dimensions) |
- |
1500 |
|
- |
| Cl. No. 8.2(Tolerances) |
- |
200 |
|
- |
| Cl. No. 9(CHEMICAL COMPOSITION) |
- |
6000 |
|
- |
| Cl. No. 10.1.1, Table no. 1(Tensile Test) |
- |
2500 |
|
- |
| Cl. No. 10.2(Flattening and Doubling-Over Test) |
- |
1900 |
|
- |
| Cl. No. 10.3(Drift Expanding Test) |
- |
2000 |
|
- |
| Cl. No. 10.4(Non-Destructive Testing) |
- |
100 |
|
- |
| Cl. No. 10.5("Microscopic Examination ( for 0 Condition
Only )") |
- |
500 |
|
- |
| Cl. No. 13(Marking) |
- |
100 |
|
- |
| 10.6(Hydrogen Embrittlement Test) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f. 15.04.2024 |
| 6893 |
Alpha Test House Services LLP (160), Sahibzada Ajit Singh Nagar
| 9138706
| IS 4412 (1981) |
Specification for copper wires for general engineering purposes (First Revision) |
Copper wires |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4(Chemical Composition) |
- |
10000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| 5.1(Tensile Test) |
- |
3500 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| 5.2(Embrittlement Test) |
- |
0 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| 6(Freedom from defect) |
- |
500 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| 7.1(Diameter and Tolerances) |
- |
1000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 ( Table -1)(Copper+Silver) |
- |
1000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 ( Table -1)(phosphorus) |
- |
500 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 ( Table -1)(Antimony) |
- |
500 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 ( Table -1)(Arsenic) |
- |
500 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 ( Table -1)(Bismuth) |
- |
500 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 ( Table -1)(Iron) |
- |
500 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 ( Table -1)(Lead) |
- |
500 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 ( Table -1)(Nckel) |
- |
500 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 ( Table -1)(Selenium+Tellurium) |
- |
4000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 ( Table -1)(Tellurium) |
- |
2000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 ( Table -1)(Tin) |
- |
500 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 ( Table -1)(Total Impurities) |
- |
1000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4(Chemical Composition) |
- |
10000 |
|
- |
| 5.1(Tensile Test) |
- |
3500 |
|
- |
| 5.2(Embrittlement Test) |
- |
0 |
|
- |
| 6(Freedom from defect) |
- |
500 |
|
- |
| 7.1(Diameter and Tolerances) |
- |
1000 |
|
- |
| Clause 4.1 ( Table -1)(Copper+Silver) |
- |
1000 |
|
- |
| Clause 4.1 ( Table -1)(phosphorus) |
- |
500 |
|
- |
| Clause 4.1 ( Table -1)(Antimony) |
- |
500 |
|
- |
| Clause 4.1 ( Table -1)(Arsenic) |
- |
500 |
|
- |
| Clause 4.1 ( Table -1)(Bismuth) |
- |
500 |
|
- |
| Clause 4.1 ( Table -1)(Iron) |
- |
500 |
|
- |
| Clause 4.1 ( Table -1)(Lead) |
- |
500 |
|
- |
| Clause 4.1 ( Table -1)(Nckel) |
- |
500 |
|
- |
| Clause 4.1 ( Table -1)(Selenium+Tellurium) |
- |
4000 |
|
- |
| Clause 4.1 ( Table -1)(Tellurium) |
- |
2000 |
|
- |
| Clause 4.1 ( Table -1)(Tin) |
- |
500 |
|
- |
| Clause 4.1 ( Table -1)(Total Impurities) |
- |
1000 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f. 15.04.2024
Exclusion: Cl.5.2 (Embrittlement Test) |
| 6894 |
Alpha Test House Services LLP (160), Sahibzada Ajit Singh Nagar
| 9138706
| IS 4171 (1983) |
Specification for copper rods and bars for general engineering purposes (First Revision) |
Copper rods & bars |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.1 Table 1(1. Copper, including silver, min) |
- |
1000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 Table 1(2. Tin, max) |
- |
1000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 Table 1(3. Lead, max) |
- |
1000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 Table 1(5. Nickel, max) |
- |
1000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 Table 1(6. Arsenic, max) |
- |
1000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 Table 1(7. Antimony, max) |
- |
1000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 Table 1(8. Bismuth, max) |
- |
1000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 Table 1(9. Phosphorus) |
- |
1000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 Table 1(10. Selenium and Tellurium, max) |
- |
1000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 Table 1(11. Total impurities ( excluding silver, nickel and phosphorus ), max) |
- |
1000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| 5.2(Hydrogen Embrittlement test) |
- |
0 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| 5.1(Tensile Properties) |
- |
4000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| 7.1(Dimension and Tolerances) |
- |
1000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Clause 4.1 Table 1(1. Copper, including silver, min) |
- |
1000 |
|
- |
| Clause 4.1 Table 1(2. Tin, max) |
- |
1000 |
|
- |
| Clause 4.1 Table 1(3. Lead, max) |
- |
1000 |
|
- |
| Clause 4.1 Table 1(5. Nickel, max) |
- |
1000 |
|
- |
| Clause 4.1 Table 1(6. Arsenic, max) |
- |
1000 |
|
- |
| Clause 4.1 Table 1(7. Antimony, max) |
- |
1000 |
|
- |
| Clause 4.1 Table 1(8. Bismuth, max) |
- |
1000 |
|
- |
| Clause 4.1 Table 1(9. Phosphorus) |
- |
1000 |
|
- |
| Clause 4.1 Table 1(10. Selenium and Tellurium, max) |
- |
1000 |
|
- |
| Clause 4.1 Table 1(11. Total impurities ( excluding silver, nickel and phosphorus ), max) |
- |
1000 |
|
- |
| 5.2(Hydrogen Embrittlement test) |
- |
0 |
|
- |
| 5.1(Tensile Properties) |
- |
4000 |
|
- |
| 7.1(Dimension and Tolerances) |
- |
1000 |
|
- |
|
31 Dec, 2026 |
- - |
| 6895 |
Hi Physix Laboratory India Private Limited, Pune
| 7126926
| IS 3315 (2024) |
Direct Evaporative Air Cooler â Specification (Fourth Revision) |
- |
82000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.1(Enclosure) |
- |
12000 |
|
- |
| Cl-5.2(Filter Pads) |
- |
0 |
|
- |
| Cl-5.3(Sump Tank Capacities) |
- |
5000 |
|
- |
| Cl-5.4(Blower/Fan) |
- |
0 |
|
- |
| Cl-5.4.3(Fan motor) |
- |
0 |
|
Compliance will be checked by pre-testing documents. In case testing is required as per IS 996 additional charges of Rs. 14334/- will be applicable. |
| Cl-5.5(Pump Set) |
- |
0 |
|
Compliance will be checked by pre-testing documents. In case testing is required as per IS 11951 additional charges of Rs. 49500/- will be applicable. |
| Cl-5.6.1(Electrical wiring and connection) |
- |
1000 |
|
- |
| Cl-5.6.2(Suitable power cable) |
- |
1000 |
|
Length of measurement of cords |
| Cl-5.7(Switches) |
- |
0 |
|
In case switch need to be tested as per Cl. 5.7 a), b), c), d). Additional Testing charges will be applicable of Rs. 10000/- |
| Cl-6(Rating Requirement) |
- |
0 |
|
- |
| Cl-8.1(Performance Requirement) |
- |
0 |
|
Charges given in main test clauses |
| Cl-8.2(Sound Test) |
- |
10000 |
|
- |
| Cl-8.3(Air Delivery (Air Flow) Test) |
- |
10000 |
|
- |
| Cl-8.4(Cooling Efficiency Test) |
- |
10000 |
|
- |
| Cl-8.5(Power Consumption) |
- |
5000 |
|
Including Power factor measurements |
| Cl-8.6(EER Calculation Method) |
- |
1000 |
|
- |
| Cl-8.7(Drop Test) |
- |
2000 |
|
- |
| Cl-8.8(Air Cooler Blower/Fan Reliability Test) |
- |
15000 |
|
- |
| Cl-12.2.1(General Running Tests) |
- |
1000 |
|
- |
| Cl-12.2.2(Protection against Electric Shock) |
- |
2000 |
|
- |
| Cl-12.2.3(High Voltage Tests) |
- |
2000 |
|
- |
| Cl-12.2.4(Leakage Current) |
- |
2000 |
|
- |
| Cl-12.2.5(Provision for Earthing) |
- |
2000 |
|
- |
| Cl-12.2.6(Finish) |
- |
1000 |
|
- |
| Cl-13(Additional Requirement for ECO-Mark) |
- |
0 |
|
- |
| Cl-14(Storage) |
- |
0 |
|
- |
| Cl-5.1(Enclosure) |
- |
0 |
|
- |
| Cl-5.2(Filter Pads) |
- |
0 |
|
- |
| Cl-5.3(Sump Tank Capacities) |
- |
0 |
|
- |
| Cl-5.4(Blower/Fan) |
- |
0 |
|
- |
| Cl-5.4.3(Fan motor) |
- |
0 |
|
- |
| Cl-5.5(Pump Set) |
- |
0 |
|
- |
| Cl-5.6.1(Electrical wiring and connection) |
- |
0 |
|
- |
| Cl-5.6.2(Suitable power cable) |
- |
0 |
|
- |
| Cl-5.7(Switches) |
- |
0 |
|
- |
| Cl-6(Rating Requirement) |
- |
0 |
|
- |
| Cl-8.1(Performance Requirement) |
- |
0 |
|
- |
| Cl-8.2(Sound Test) |
- |
0 |
|
- |
| Cl-8.3(Air Delivery (Air Flow) Test) |
- |
0 |
|
- |
| Cl-8.4(Cooling Efficiency Test) |
- |
0 |
|
- |
| Cl-8.5(Power Consumption) |
- |
0 |
|
- |
| Cl-8.6(EER Calculation Method) |
- |
0 |
|
- |
| Cl-8.7(Drop Test) |
- |
0 |
|
- |
| Cl-8.8(Air Cooler Blower/Fan Reliability Test) |
- |
0 |
|
- |
| Cl-12.2.1(General Running Tests) |
- |
0 |
|
- |
| Cl-12.2.2(Protection against Electric Shock) |
- |
0 |
|
- |
| Cl-12.2.3(High Voltage Tests) |
- |
0 |
|
- |
| Cl-12.2.4(Leakage Current) |
- |
0 |
|
- |
| Cl-12.2.5(Provision for Earthing) |
- |
0 |
|
- |
| Cl-12.2.6(Finish) |
- |
0 |
|
- |
| Cl-13(Additional Requirement for ECO-Mark) |
- |
0 |
|
- |
| Cl-14(Storage) |
- |
0 |
|
- |
| Cl-5.1(Enclosure) |
- |
0 |
|
- |
| Cl-5.2(Filter Pads) |
- |
0 |
|
- |
| Cl-5.3(Sump Tank Capacities) |
- |
0 |
|
- |
| Cl-5.4(Blower/Fan) |
- |
0 |
|
- |
| Cl-5.4.3(Fan motor) |
- |
0 |
|
- |
| Cl-5.5(Pump Set) |
- |
0 |
|
- |
| Cl-5.6.1(Electrical wiring and connection) |
- |
0 |
|
- |
| Cl-5.6.2(Suitable power cable) |
- |
0 |
|
- |
| Cl-5.7(Switches) |
- |
0 |
|
- |
| Cl-6(Rating Requirement) |
- |
0 |
|
- |
| Cl-8.1(Performance Requirement) |
- |
0 |
|
- |
| Cl-8.2(Sound Test) |
- |
0 |
|
- |
| Cl-8.3(Air Delivery (Air Flow) Test) |
- |
0 |
|
- |
| Cl-8.4(Cooling Efficiency Test) |
- |
0 |
|
- |
| Cl-8.5(Power Consumption) |
- |
0 |
|
- |
| Cl-8.6(EER Calculation Method) |
- |
0 |
|
- |
| Cl-8.7(Drop Test) |
- |
0 |
|
- |
| Cl-8.8(Air Cooler Blower/Fan Reliability Test) |
- |
0 |
|
- |
| Cl-12.2.1(General Running Tests) |
- |
0 |
|
- |
| Cl-12.2.2(Protection against Electric Shock) |
- |
0 |
|
- |
| Cl-12.2.3(High Voltage Tests) |
- |
0 |
|
- |
| Cl-12.2.4(Leakage Current) |
- |
0 |
|
- |
| Cl-12.2.5(Provision for Earthing) |
- |
0 |
|
- |
| Cl-12.2.6(Finish) |
- |
0 |
|
- |
| Cl-13(Additional Requirement for ECO-Mark) |
- |
0 |
|
- |
| Cl-14(Storage) |
- |
0 |
|
- |
| Cl-5.1(Enclosure) |
- |
0 |
|
- |
| Cl-5.2(Filter Pads) |
- |
0 |
|
- |
| Cl-5.3(Sump Tank Capacities) |
- |
0 |
|
- |
| Cl-5.4(Blower/Fan) |
- |
0 |
|
- |
| Cl-5.4.3(Fan motor) |
- |
0 |
|
- |
| Cl-5.5(Pump Set) |
- |
0 |
|
- |
| Cl-5.6.1(Electrical wiring and connection) |
- |
0 |
|
- |
| Cl-5.6.2(Suitable power cable) |
- |
0 |
|
- |
| Cl-5.7(Switches) |
- |
0 |
|
- |
| Cl-6(Rating Requirement) |
- |
0 |
|
- |
| Cl-8.1(Performance Requirement) |
- |
0 |
|
- |
| Cl-8.2(Sound Test) |
- |
0 |
|
- |
| Cl-8.3(Air Delivery (Air Flow) Test) |
- |
0 |
|
- |
| Cl-8.4(Cooling Efficiency Test) |
- |
0 |
|
- |
| Cl-8.5(Power Consumption) |
- |
0 |
|
- |
| Cl-8.6(EER Calculation Method) |
- |
0 |
|
- |
| Cl-8.7(Drop Test) |
- |
0 |
|
- |
| Cl-8.8(Air Cooler Blower/Fan Reliability Test) |
- |
0 |
|
- |
| Cl-12.2.1(General Running Tests) |
- |
0 |
|
- |
| Cl-12.2.2(Protection against Electric Shock) |
- |
0 |
|
- |
| Cl-12.2.3(High Voltage Tests) |
- |
0 |
|
- |
| Cl-12.2.4(Leakage Current) |
- |
0 |
|
- |
| Cl-12.2.5(Provision for Earthing) |
- |
0 |
|
- |
| Cl-12.2.6(Finish) |
- |
0 |
|
- |
| Cl-13(Additional Requirement for ECO-Mark) |
- |
0 |
|
- |
| Cl-14(Storage) |
- |
0 |
|
- |
| Cl-5.1(Enclosure) |
- |
0 |
|
- |
| Cl-5.2(Filter Pads) |
- |
0 |
|
- |
| Cl-5.3(Sump Tank Capacities) |
- |
0 |
|
- |
| Cl-5.4(Blower/Fan) |
- |
0 |
|
- |
| Cl-5.4.3(Fan motor) |
- |
0 |
|
- |
| Cl-5.5(Pump Set) |
- |
0 |
|
- |
| Cl-5.6.1(Electrical wiring and connection) |
- |
0 |
|
- |
| Cl-5.6.2(Suitable power cable) |
- |
0 |
|
- |
| Cl-5.7(Switches) |
- |
0 |
|
- |
| Cl-6(Rating Requirement) |
- |
0 |
|
- |
| Cl-8.1(Performance Requirement) |
- |
0 |
|
- |
| Cl-8.2(Sound Test) |
- |
0 |
|
- |
| Cl-8.3(Air Delivery (Air Flow) Test) |
- |
0 |
|
- |
| Cl-8.4(Cooling Efficiency Test) |
- |
0 |
|
- |
| Cl-8.5(Power Consumption) |
- |
0 |
|
- |
| Cl-8.6(EER Calculation Method) |
- |
0 |
|
- |
| Cl-8.7(Drop Test) |
- |
0 |
|
- |
| Cl-8.8(Air Cooler Blower/Fan Reliability Test) |
- |
0 |
|
- |
| Cl-12.2.1(General Running Tests) |
- |
0 |
|
- |
| Cl-12.2.2(Protection against Electric Shock) |
- |
0 |
|
- |
| Cl-12.2.3(High Voltage Tests) |
- |
0 |
|
- |
| Cl-12.2.4(Leakage Current) |
- |
0 |
|
- |
| Cl-12.2.5(Provision for Earthing) |
- |
0 |
|
- |
| Cl-12.2.6(Finish) |
- |
0 |
|
- |
| Cl-13(Additional Requirement for ECO-Mark) |
- |
0 |
|
- |
| Cl-14(Storage) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f. 05.11.2024 |
| 6896 |
BIS, Central Laboratory (CL)
| None
| IS 8028 (2023) |
QUINALPHOS EMULSIFIABLE CONCENTRATE SPECIFICATION second revision |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| CL 3.2.1 (Description) |
- |
|
|
|
| Cl. 3.2.2 (Cold Test) |
- |
|
|
|
| CL 3.2.3 (Flash Point) |
- |
|
|
|
| CL 3.2.4 (Emul;sion Stability) |
- |
|
|
|
| CL 3.2.5 (Acidity) |
- |
|
|
|
|
- |
- - |
| 6897 |
Bharat Test House Pvt. Ltd. 1668 Sonipat
| 9168306
| IS 3735 (1996) |
Canvas Shoes, Rubber Sole |
Canvas Shoes, Rubber Sole |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.4.5 Consolidation Test
IS 3400 (Part 5) : 1986 (From the quarter, cut a strip of 25.0 ± 0.5 mm width along the leagth of the boot
and of sufficient length to permit separation over a length of 75 mm. Carry out the test on two test pieces (one from each odd) at the rate of traverse of 100± 10mm per minute in accordance with IS 3400 (Part 5): 1986 or Static Dead Load
Method as given in Annex C. The individual adhesion value for consolidation test shall not be less than 30N (3.0 kgf) for each of the teat piecea (see Note
under 4.4).') |
- |
100 |
|
- |
| 4.1.1 Upper, Sl No. (i) of Table 1(The upper shall consist of over layer of cotton, manmade or blended
conforming' to the requirements given in Sl No. (i) of Table 1 as an overlayer and cotton drill conforming to the
requirements given in Sl No. (ii) of Table 1, as an inner layer or lining. The two fabrics shall be firmly adhered together with rubber compound. ) |
- |
100 |
|
- |
| Cl.4.1.1.1 Colour fastness(The dyed fabrics prescribed in 4.1.1 shall be fast todaylight and mechanical washing. Fastness to daylight
shall be of rating 4 or better, when tested in accordance with IS 686 : 1985 or IS 2454: 1985. However in case of dispute the method prescribed in IS 686 : 1985
shall be considered as referee method.) |
- |
100 |
|
- |
| Cl.4.1.2 Binding Material(IS 1954 : 1990)
(IS1969 : 1985)(Cotton tape NEWAR used as binding material shall conform to the requirements prescribed in col 3 of
Table 2, when tested in accordance with the methods referred to in col 4 of the table.) |
- |
100 |
|
- |
| Cl.4.1.2.1
Anmex B.(Cotton, manmade or blended shall be used as binding material.'
'Coloured cotton tapes shall have fastness to day light of rating as and if agreed
to between the purchaser and the supplier when tested in accordance with IS 686 :
1985. The black tapes shall be free from sulphur dyes when tested in accordance
with Annex B.') |
- |
100 |
|
- |
| Cl.4.1.3.1( Sewing thread cotton, manmade or blended shall be used for stitching of
upper. For cotton variety thread shall conform to variety No. 28 of IS 1720.
Polyester variety thread shall conform to variety No. 9 of IS 9543. Any other suitable thread shall have breaking load not less than above referred
requirement of specification.
Sewing thread cotton, manmade or blended shall be used for binding of upper. For cotton variety thread shall conform to variety No. 32 of IS 1720. Polyester variety thread shall conform to variety No. 5 of IS 9543.
Any other suitable thread shall have breaking load not less than above referred
requirement of specification.') |
- |
100 |
|
- |
| Cl.4.3.3( The counter shall be stitched at the back, set from bottom of lining and bound flat on top edge
with white/scoured binding material cut in bias and formed as a tape. T ) |
- |
100 |
|
- |
| Cl.4.1.4(.Brass, steel or aluminium eyelets of 7.5 mm diameter and wall thickness 0.30 to
0.35 mm shall be used.') |
- |
100 |
|
- |
| Cl.4.1.5 Laces(
The shoes shall be provided with fabric braided laces
either matching the shade of the upper or black or The length of the lace shall be 60 ± 3 cm ) |
- |
100 |
|
- |
| Cl.4.1.5 Laces(and shallhave the breaking strength of not less than 250 N when tested between 18 cm grips in accordance with
IS 1969 : 1985, the rate of traverse of power actuated grip being 300 mm/min.) |
- |
100 |
|
- |
| Cl.4.1.5 Laces
Annex B(In case the laces are black,
the same shall pass the test for freedom from sulpher
dyes when tested in accordance with Annex B. The
two ends of the lace shall be provided with suitable
metal or plastic tips.) |
- |
100 |
|
- |
| Cl.4.1.6 Rubber Components(The rubber components shall conform to the requirements given in Table 4, when tested from finished boots.However in case it is not possible to cut the test pieces from the made up boots then 4.1.5.3 of IS
13695 : 1993 shall be followed.') |
- |
100 |
|
- |
| Cl.4.1.6.2 Ageing
col 4 of Table 5.(The shoes shall be also aged at 70 ± 1°C for 168 h, on completion of which the test pieces taken from the shoes shall conform to the physical requirements
prescribed in col 4 of Table 5. ) |
- |
100 |
|
- |
| Cl.4.1.6.2 Ageing
(None of the rubber components of the shoes shall show any sign of tackiness or crack developed after ageing, when examined visually) |
- |
100 |
|
- |
| Cl.4.1.6.3 Thickness of components
in Table 6.(Individual components of the shoes shall comply with
the thickness and material requirements prescribed
in Table 6.) |
- |
100 |
|
- |
| CL.4.2 Shape and Design
IS 1638 : 1969(Cl 4.2.1 The shoes shall be made according to design
and pattern as agreed to between the purchaser and
the supplier. Size and fittings of the shoes shall be
in accordance with IS 1638 : 1969 unless otherwise
specified by the purchaser.) |
- |
100 |
|
- |
| Cl.4.2.2( The recommended design of canvas shoes is
shown in Fig. 1.) |
- |
100 |
|
- |
| Cl.4.3 Construction
Cl 4.3.1( The upper shall be stitched on a lock stitch machine and the number of stitches shall be 30 to
40 per dm.) |
- |
100 |
|
- |
| Cl.'4.3.2( Back of the upper shall be reinforced with a strip of upper material when
there is a seam.') |
- |
100 |
|
- |
| Cl.4.3.3( The counter shall be stitched at the back, set from bottom of lining and bound flat on top edge
with white/scoured binding material cut in bias and formed as a tape. T ) |
- |
100 |
|
- |
| Cl.4.3.3(he number of stitches shall be
30 to 40 per decimetre. The counter binding shall
meet the binding of the upper at the centre top edge
of the heel.) |
- |
100 |
|
- |
| Cl.4.4 Adhesion Test(From the upper-foxing portion where it is adhered to the canvas, parallel to the waist of sole, cut a strip of length 100 mm and width 8 mm. Separate out
the plies initially by breaking the bond to a length of about 75 mm. Carry out the test on two specimens in accordance with IS 3400 (Part 5) : 1986. There
shall be no further separation within 1 minute at a load of 1 kg for each of the two specimens.) |
- |
100 |
|
- |
| CL.4.6 Mass(The mass of one pair of finished shoes of size 8 shall not exceed 750 g with an increase or decrease of 25 g for each bigger or smaller size respectively) |
- |
100 |
|
- |
| Cl.4.3.3(he number of stitches shall be
30 to 40 per decimetre. The counter binding shall
meet the binding of the upper at the centre top edge
of the heel.) |
- |
100 |
|
- |
| Cl.4.5 Consolidation Test
IS 3400 (Part 5) : 1986 (From the quarter, cut a strip of 25.0 ± 0.5 mm width along the leagth of the boot
and of sufficient length to permit separation over a length of 75 mm. Carry out the test on two test pieces (one from each odd) at the rate of traverse of 100± 10mm per minute in accordance with IS 3400 (Part 5): 1986 or Static Dead Load
Method as given in Annex C. The individual adhesion value for consolidation test shall not be less than 30N (3.0 kgf) for each of the teat piecea (see Note
under 4.4).') |
- |
100 |
|
- |
| 4.1.1 Upper, Sl No. (i) of Table 1(The upper shall consist of over layer of cotton, manmade or blended
conforming' to the requirements given in Sl No. (i) of Table 1 as an overlayer and cotton drill conforming to the
requirements given in Sl No. (ii) of Table 1, as an inner layer or lining. The two fabrics shall be firmly adhered together with rubber compound. ) |
- |
100 |
|
- |
| Cl.4.1.1.1 Colour fastness(The dyed fabrics prescribed in 4.1.1 shall be fast todaylight and mechanical washing. Fastness to daylight
shall be of rating 4 or better, when tested in accordance with IS 686 : 1985 or IS 2454: 1985. However in case of dispute the method prescribed in IS 686 : 1985
shall be considered as referee method.) |
- |
100 |
|
- |
| Cl.4.1.2 Binding Material(IS 1954 : 1990)
(IS1969 : 1985)(Cotton tape NEWAR used as binding material shall conform to the requirements prescribed in col 3 of
Table 2, when tested in accordance with the methods referred to in col 4 of the table.) |
- |
100 |
|
- |
| Cl.4.1.2.1
Anmex B.(Cotton, manmade or blended shall be used as binding material.'
'Coloured cotton tapes shall have fastness to day light of rating as and if agreed
to between the purchaser and the supplier when tested in accordance with IS 686 :
1985. The black tapes shall be free from sulphur dyes when tested in accordance
with Annex B.') |
- |
100 |
|
- |
| Cl.4.1.3.1( Sewing thread cotton, manmade or blended shall be used for stitching of
upper. For cotton variety thread shall conform to variety No. 28 of IS 1720.
Polyester variety thread shall conform to variety No. 9 of IS 9543. Any other suitable thread shall have breaking load not less than above referred
requirement of specification.
Sewing thread cotton, manmade or blended shall be used for binding of upper. For cotton variety thread shall conform to variety No. 32 of IS 1720. Polyester variety thread shall conform to variety No. 5 of IS 9543.
Any other suitable thread shall have breaking load not less than above referred
requirement of specification.') |
- |
100 |
|
- |
| Cl.4.1.3.2 (IS 2454 : 1985)
IS 765 : 1979
IS 971 : 1966( The colour of the threads shall be as agreedto between the purchaser and the supplier. The dyed threads shall conform to the following requirements or IS 686 : 1985'.) |
- |
100 |
|
- |
| Cl.4.1.4(.Brass, steel or aluminium eyelets of 7.5 mm diameter and wall thickness 0.30 to
0.35 mm shall be used.') |
- |
100 |
|
- |
| Cl.4.1.5 Laces(
The shoes shall be provided with fabric braided laces
either matching the shade of the upper or black or The length of the lace shall be 60 ± 3 cm ) |
- |
100 |
|
- |
| Cl.4.1.5 Laces(and shallhave the breaking strength of not less than 250 N when tested between 18 cm grips in accordance with
IS 1969 : 1985, the rate of traverse of power actuated grip being 300 mm/min.) |
- |
100 |
|
- |
| Cl.4.1.5 Laces
Annex B(In case the laces are black,
the same shall pass the test for freedom from sulpher
dyes when tested in accordance with Annex B. The
two ends of the lace shall be provided with suitable
metal or plastic tips.) |
- |
100 |
|
- |
| Cl.4.1.6 Rubber Components(The rubber components shall conform to the requirements given in Table 4, when tested from finished boots.However in case it is not possible to cut the test pieces from the made up boots then 4.1.5.3 of IS
13695 : 1993 shall be followed.') |
- |
100 |
|
- |
| Cl.4.1.6.2 Ageing
col 4 of Table 5.(The shoes shall be also aged at 70 ± 1°C for 168 h, on completion of which the test pieces taken from the shoes shall conform to the physical requirements
prescribed in col 4 of Table 5. ) |
- |
100 |
|
- |
| Cl.4.1.6.2 Ageing
(None of the rubber components of the shoes shall show any sign of tackiness or crack developed after ageing, when examined visually) |
- |
100 |
|
- |
| Cl.4.1.6.3 Thickness of components
in Table 6.(Individual components of the shoes shall comply with
the thickness and material requirements prescribed
in Table 6.) |
- |
100 |
|
- |
| CL.4.2 Shape and Design
IS 1638 : 1969(Cl 4.2.1 The shoes shall be made according to design
and pattern as agreed to between the purchaser and
the supplier. Size and fittings of the shoes shall be
in accordance with IS 1638 : 1969 unless otherwise
specified by the purchaser.) |
- |
100 |
|
- |
| Cl.4.2.2( The recommended design of canvas shoes is
shown in Fig. 1.) |
- |
100 |
|
- |
| Cl.4.3 Construction
Cl 4.3.1( The upper shall be stitched on a lock stitch machine and the number of stitches shall be 30 to
40 per dm.) |
- |
100 |
|
- |
| Cl.'4.3.2( Back of the upper shall be reinforced with a strip of upper material when
there is a seam.') |
- |
100 |
|
- |
| Cl.4.4 Adhesion Test(From the upper-foxing portion where it is adhered to the canvas, parallel to the waist of sole, cut a strip of length 100 mm and width 8 mm. Separate out
the plies initially by breaking the bond to a length of about 75 mm. Carry out the test on two specimens in accordance with IS 3400 (Part 5) : 1986. There
shall be no further separation within 1 minute at a load of 1 kg for each of the two specimens.) |
- |
100 |
|
- |
| CL.4.6 Mass(The mass of one pair of finished shoes of size 8 shall not exceed 750 g with an increase or decrease of 25 g for each bigger or smaller size respectively) |
- |
100 |
|
- |
| Cl.4.5 Consolidation Test
IS 3400 (Part 5) : 1986 (From the quarter, cut a strip of 25.0 ± 0.5 mm width along the leagth of the boot
and of sufficient length to permit separation over a length of 75 mm. Carry out the test on two test pieces (one from each odd) at the rate of traverse of 100± 10mm per minute in accordance with IS 3400 (Part 5): 1986 or Static Dead Load
Method as given in Annex C. The individual adhesion value for consolidation test shall not be less than 30N (3.0 kgf) for each of the teat piecea (see Note
under 4.4).') |
- |
100 |
|
- |
| 4.1.1 Upper, Sl No. (i) of Table 1(The upper shall consist of over layer of cotton, manmade or blended
conforming' to the requirements given in Sl No. (i) of Table 1 as an overlayer and cotton drill conforming to the
requirements given in Sl No. (ii) of Table 1, as an inner layer or lining. The two fabrics shall be firmly adhered together with rubber compound. ) |
- |
100 |
|
- |
| Cl.4.1.1.1 Colour fastness(The dyed fabrics prescribed in 4.1.1 shall be fast todaylight and mechanical washing. Fastness to daylight
shall be of rating 4 or better, when tested in accordance with IS 686 : 1985 or IS 2454: 1985. However in case of dispute the method prescribed in IS 686 : 1985
shall be considered as referee method.) |
- |
100 |
|
- |
| Cl.4.1.2 Binding Material(IS 1954 : 1990)
(IS1969 : 1985)(Cotton tape NEWAR used as binding material shall conform to the requirements prescribed in col 3 of
Table 2, when tested in accordance with the methods referred to in col 4 of the table.) |
- |
100 |
|
- |
| Cl.4.1.2.1
Anmex B.(Cotton, manmade or blended shall be used as binding material.'
'Coloured cotton tapes shall have fastness to day light of rating as and if agreed
to between the purchaser and the supplier when tested in accordance with IS 686 :
1985. The black tapes shall be free from sulphur dyes when tested in accordance
with Annex B.') |
- |
100 |
|
- |
| Cl.4.1.3.1( Sewing thread cotton, manmade or blended shall be used for stitching of
upper. For cotton variety thread shall conform to variety No. 28 of IS 1720.
Polyester variety thread shall conform to variety No. 9 of IS 9543. Any other suitable thread shall have breaking load not less than above referred
requirement of specification.
Sewing thread cotton, manmade or blended shall be used for binding of upper. For cotton variety thread shall conform to variety No. 32 of IS 1720. Polyester variety thread shall conform to variety No. 5 of IS 9543.
Any other suitable thread shall have breaking load not less than above referred
requirement of specification.') |
- |
100 |
|
- |
| Cl.4.1.4(.Brass, steel or aluminium eyelets of 7.5 mm diameter and wall thickness 0.30 to
0.35 mm shall be used.') |
- |
100 |
|
- |
| Cl.4.1.5 Laces(
The shoes shall be provided with fabric braided laces
either matching the shade of the upper or black or The length of the lace shall be 60 ± 3 cm ) |
- |
100 |
|
- |
| Cl.4.1.5 Laces(and shallhave the breaking strength of not less than 250 N when tested between 18 cm grips in accordance with
IS 1969 : 1985, the rate of traverse of power actuated grip being 300 mm/min.) |
- |
100 |
|
- |
| Cl.4.1.5 Laces
Annex B(In case the laces are black,
the same shall pass the test for freedom from sulpher
dyes when tested in accordance with Annex B. The
two ends of the lace shall be provided with suitable
metal or plastic tips.) |
- |
100 |
|
- |
| Cl.4.1.6 Rubber Components(The rubber components shall conform to the requirements given in Table 4, when tested from finished boots.However in case it is not possible to cut the test pieces from the made up boots then 4.1.5.3 of IS
13695 : 1993 shall be followed.') |
- |
100 |
|
- |
| Cl.4.1.6.2 Ageing
col 4 of Table 5.(The shoes shall be also aged at 70 ± 1°C for 168 h, on completion of which the test pieces taken from the shoes shall conform to the physical requirements
prescribed in col 4 of Table 5. ) |
- |
100 |
|
- |
| Cl.4.1.6.2 Ageing
(None of the rubber components of the shoes shall show any sign of tackiness or crack developed after ageing, when examined visually) |
- |
100 |
|
- |
| Cl.4.1.6.3 Thickness of components
in Table 6.(Individual components of the shoes shall comply with
the thickness and material requirements prescribed
in Table 6.) |
- |
100 |
|
- |
| Cl.4.3 Construction
Cl 4.3.1( The upper shall be stitched on a lock stitch machine and the number of stitches shall be 30 to
40 per dm.) |
- |
100 |
|
- |
| Cl.4.4 Adhesion Test(From the upper-foxing portion where it is adhered to the canvas, parallel to the waist of sole, cut a strip of length 100 mm and width 8 mm. Separate out
the plies initially by breaking the bond to a length of about 75 mm. Carry out the test on two specimens in accordance with IS 3400 (Part 5) : 1986. There
shall be no further separation within 1 minute at a load of 1 kg for each of the two specimens.) |
- |
100 |
|
- |
| CL.4.6 Mass(The mass of one pair of finished shoes of size 8 shall not exceed 750 g with an increase or decrease of 25 g for each bigger or smaller size respectively) |
- |
100 |
|
- |
| 4.8(Adhesion ) |
- |
100 |
|
- |
| 4.7(Consolidation test ) |
- |
100 |
|
- |
| 4.6(Mass ) |
- |
100 |
|
- |
| 4.5(Finish ) |
- |
100 |
|
- |
| 4.4(Contruction ) |
- |
100 |
|
- |
| 4.3(Leg Height ) |
- |
100 |
|
- |
| 4.2(Design ) |
- |
100 |
|
- |
| 4.1.6.2(Thickness of components ) |
- |
100 |
|
- |
| 4.1.6.2(Ageing) |
- |
100 |
|
- |
| 4.1.6.2(Elongation at break after ageing ) |
- |
100 |
|
- |
| 4.1.6.2(Tensile after ageing ) |
- |
100 |
|
- |
| 4.1.6(Compression set ) |
- |
100 |
|
- |
| 4.1.6(Elongation at break ) |
- |
100 |
|
- |
| 4.1.6(Tensile strength) |
- |
100 |
|
- |
| 4.1.6(Hardness (after accelerated )) |
- |
100 |
|
- |
| 4.1.6(Flexing resistance test) |
- |
100 |
|
- |
| 4.1.6(Hardness ) |
- |
100 |
|
- |
| 4.1.6(Relative density) |
- |
100 |
|
- |
| 4.1.5(Sulpher dyes content ) |
- |
100 |
|
- |
| 4.1.5(Breaking Load ) |
- |
100 |
|
- |
| 4.1.5(Length ) |
- |
100 |
|
- |
| 4.1.4(Thickness) |
- |
100 |
|
- |
| 4.1.4(Size ) |
- |
100 |
|
- |
| 4.1.3(Color fastness to perspiration) |
- |
100 |
|
- |
| 4.1.3(Colorfastness to washing) |
- |
100 |
|
- |
| 4.1.3(Colorfastness to light ) |
- |
100 |
|
- |
| 4.1.3(Single thread breaking load) |
- |
100 |
|
- |
| 4.1.1.2(Colorfastness to washing) |
- |
100 |
|
- |
| 4.1.1.1(Colorfastness to light ) |
- |
100 |
|
- |
| 4.1.1 (Drill) (End & Picks/dm) |
- |
100 |
|
- |
| 4.1.1 (canvas )(End & Picks/dm) |
- |
100 |
|
- |
| 4.1.1 (canvas )(Breaking Load ) |
- |
100 |
|
- |
| 5, 5.1, Cl. 5.2, Cl. 5.2.1, Cl. 5.2.1.1(Packing and marking) |
- |
100 |
|
- |
| " CL. 5.1, Cl. 5.2, Cl. 5.2.1, Cl. 5.2.1.1(Packing and marking ") |
- |
100 |
|
- |
| Cl.4.3.3(The edges of quarter shall be bound with
dyed cotton binding material or matching to the colour
of the upper, cut in bias and formed as a tape.) |
- |
100 |
|
- |
| Cl.4.3.4 (The vantp shall be strengthened with a rubber
toe-cap (see Fig. 1).) |
- |
100 |
|
- |
| Cl.4.3.5( Five pairs of eyelets shall be fitted in each
shoe. The eyelets shall be properly clenched without
any distortion. It shall properly match the colour of
the upper canvas, or as agreed to between the purchaser
and the supplier.) |
- |
100 |
|
- |
| Cl.4.3.6( The shoes shall be free from folds, wrinkles in the upper, blisters, embedded foreign matters and
excessive surface markings. In appearance, general workmanship, finish and all other respects, not defined
in the standard, the shoes shall be similar to the
sample approved by the purchaser, if any) |
- |
100 |
|
- |
| CL.4.3.7( The soles shall be of even substance and ofone layer only.) |
- |
100 |
|
- |
| Cl.4.3.8( A rubber foxing shall be fixed all round the sole and heel. The colour shall be as agreed to between the purchaser and the supplier. ) |
- |
100 |
|
- |
| Cl.4.3.8(The foxing, not less
than 18 mm wide, shall not extend beyond the edges of the sole at the bottom) |
- |
100 |
|
- |
| Cl.4.3.3(The edges of quarter shall be bound with
dyed cotton binding material or matching to the colour
of the upper, cut in bias and formed as a tape.) |
- |
100 |
|
- |
| Cl.4.3.4 (The vantp shall be strengthened with a rubber
toe-cap (see Fig. 1).) |
- |
100 |
|
- |
| Cl.4.3.5( Five pairs of eyelets shall be fitted in each
shoe. The eyelets shall be properly clenched without
any distortion. It shall properly match the colour of
the upper canvas, or as agreed to between the purchaser
and the supplier.) |
- |
100 |
|
- |
| Cl.4.3.6( The shoes shall be free from folds, wrinkles in the upper, blisters, embedded foreign matters and
excessive surface markings. In appearance, general workmanship, finish and all other respects, not defined
in the standard, the shoes shall be similar to the
sample approved by the purchaser, if any) |
- |
100 |
|
- |
| CL.4.3.7( The soles shall be of even substance and ofone layer only.) |
- |
100 |
|
- |
| Cl.4.3.8( A rubber foxing shall be fixed all round the sole and heel. The colour shall be as agreed to between the purchaser and the supplier. ) |
- |
100 |
|
- |
| Cl.4.3.8(The foxing, not less
than 18 mm wide, shall not extend beyond the edges of the sole at the bottom) |
- |
100 |
|
- |
| CL.4.2 Shape and Design
IS 1638 : 1969(Cl 4.2.1 The shoes shall be made according to design
and pattern as agreed to between the purchaser and
the supplier. Size and fittings of the shoes shall be
in accordance with IS 1638 : 1969 unless otherwise
specified by the purchaser.) |
- |
200 |
|
- |
| Cl.4.2.2( The recommended design of canvas shoes is
shown in Fig. 1.) |
- |
200 |
|
- |
| Cl.'4.3.2( Back of the upper shall be reinforced with a strip of upper material when
there is a seam.') |
- |
200 |
|
- |
| Cl.4.3.3( The counter shall be stitched at the back, set from bottom of lining and bound flat on top edge
with white/scoured binding material cut in bias and formed as a tape. T ) |
- |
200 |
|
- |
| Cl.4.3.3(he number of stitches shall be
30 to 40 per decimetre. The counter binding shall
meet the binding of the upper at the centre top edge
of the heel.) |
- |
200 |
|
- |
| Cl.4.3.3(The edges of quarter shall be bound with
dyed cotton binding material or matching to the colour
of the upper, cut in bias and formed as a tape.) |
- |
200 |
|
- |
| Cl.4.3.4 (The vantp shall be strengthened with a rubber
toe-cap (see Fig. 1).) |
- |
200 |
|
- |
| Cl.4.3.5( Five pairs of eyelets shall be fitted in each
shoe. The eyelets shall be properly clenched without
any distortion. It shall properly match the colour of
the upper canvas, or as agreed to between the purchaser
and the supplier.) |
- |
200 |
|
- |
| Cl.4.3.6( The shoes shall be free from folds, wrinkles in the upper, blisters, embedded foreign matters and
excessive surface markings. In appearance, general workmanship, finish and all other respects, not defined
in the standard, the shoes shall be similar to the
sample approved by the purchaser, if any) |
- |
200 |
|
- |
| CL.4.3.7( The soles shall be of even substance and ofone layer only.) |
- |
200 |
|
- |
| Cl.4.3.8( A rubber foxing shall be fixed all round the sole and heel. The colour shall be as agreed to between the purchaser and the supplier. ) |
- |
200 |
|
- |
| Cl.4.3.8(The foxing, not less
than 18 mm wide, shall not extend beyond the edges of the sole at the bottom) |
- |
200 |
|
- |
| 4.1.2(Colorfastness to light ) |
- |
200 |
|
- |
| 4.1.2(Colorfastness to washing) |
- |
200 |
|
- |
| 4.1.2(Breaking Strength ) |
- |
200 |
|
- |
| 4.1.2(Width ) |
- |
200 |
|
- |
| Cl.4.1.3.2 (IS 2454 : 1985)
IS 765 : 1979
IS 971 : 1966( The colour of the threads shall be as agreedto between the purchaser and the supplier. The dyed threads shall conform to the following requirements or IS 686 : 1985'.) |
- |
200 |
|
- |
| Cl.4.1.3.2 (IS 2454 : 1985)
IS 765 : 1979
IS 971 : 1966( The colour of the threads shall be as agreedto between the purchaser and the supplier. The dyed threads shall conform to the following requirements or IS 686 : 1985'.) |
- |
200 |
|
- |
| 4.1.3(Construction ) |
- |
200 |
|
- |
| 4.1.1 (Drill) (Colorfastness to light ) |
- |
200 |
|
- |
|
26 Jul, 2027 |
- Included w.e.f 27.11.2024 |
| 6898 |
International Testing Centre, MSME Technology Development Centre, Meerut
| 8177804
| IS 17043 : Part 2 (2024) |
Shoes: Shoes for General Purpose |
- |
42500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.1(Shape and Design) |
- |
500 |
|
- |
| Cl-5.3(Material) |
- |
500 |
|
- |
| Cl-5.4, Table-1 (i)(Bond strength, N/mm, Min Upper to outsole, N/mm, Min) |
- |
500 |
|
- |
| Cl-5.4, Table-1 (ii)(Inter layer bond strength,= N/mm, Min Midsole to outsole, N/mm, Min) |
- |
500 |
|
- |
| Cl-5.4, Table-1 (iii)(Whole shoe flexing, flexes) |
- |
1000 |
|
- |
| Cl-5.4, Table-1 (iv)(Water proofness on complete shoe) |
- |
1000 |
|
- |
| Cl-5.4, Table-1 (v)(Slip resistance, Cof(1), Min dry and wet* (quarry tile)) |
- |
1500 |
|
- |
| Cl-5.4, Table-1 (vi)(Attachment strength of strap and buckle/D-ring N) |
- |
500 |
|
- |
| Cl-5.4, Table-1 (vii)(Attachment strength of strap and velcro , N, Min) |
- |
500 |
|
- |
| Cl-5.4, Table-1 (viii)(Strength of eyelet attachment, N, Min) |
- |
500 |
|
- |
| Cl-5.4, Table-1 (ix)(Heel pull off strength, N, Min) |
- |
500 |
|
- |
| Cl-5.4, Table-1 (x)(Top piece attachment strength, N, Min) |
- |
500 |
|
- |
| Cl-5.4, Table-1 (xi)(Seam strength, N/mm, Min) |
- |
50 |
|
- |
| Cl-5.4, Table-1 (xii)(Whole shoe topline strength, N, Min) |
- |
500 |
|
- |
| Cl-5.4, Table-1 (xiii)(Abrasion resistance (volume loss), mm3) |
- |
1000 |
|
- |
| Cl-5.4, Table-1 (xiv)(Chemical requirements(3)) |
- |
20000 |
|
- |
| Cl-5.4, Table-1 (xv)(Lead content (as Pb) ppm, Max) |
- |
2000 |
|
- |
| Cl-5.4, Table-1 (xvi)(Hydrolysis resistance,(4) cut growth at 150 000 flexes, mm, Max) |
- |
1000 |
|
- |
| Cl-6.1.1, Table-2 (i)(Tear trength, N) |
- |
500 |
|
- |
| Cl-6.1.1, Table-2 (ii)(Flexing resistance, flexes) |
- |
1000 |
|
- |
| Cl-6.1.1, Table-2 (iii)(Colour fastness to rubbing (marring/staining)) |
- |
500 |
|
- |
| Cl-6.1.1, Table-2 (iv)(Colour fastness to water (contact method- multi fabrics)) |
- |
500 |
|
- |
| Cl-6.1.1, Table-2 (v)(Water vapour permeability,mg/cm2 /h, Min Water vapour coefficient,mg/cm2 , Min) |
- |
1000 |
|
- |
| Cl-6.1.1, Table-2 (vi)(Stitch tear strength, N/mm, Min) |
- |
500 |
|
- |
| Cl-6.1.1, Table-2 (vii)(Abrasion resistance) |
- |
1000 |
|
- |
| Cl-6.1.2, Table-3 (i)(Colour fastness to light, Marring, Min) |
- |
1500 |
|
- |
| Cl-6.1.2, Table-3 (ii)(Water resistance) |
- |
500 |
|
- |
| Cl-6.1.2, Table-3 (iii)(Flexing resistance, flexes at (-) 5 °C 25 000 flexes) |
- |
800 |
|
- |
| Cl-6.1.3, Table- 4 (i)(Breaking strength, N/mm, Min Elongation at break, percent, Min) |
- |
500 |
|
- |
| Cl-6.1.3, Table- 4 (ii)(Tear Strength, N, Min) |
- |
500 |
|
- |
| Cl-6.1.3, Table- 4 (iii)(Strength at needle perforation, N/mm, Min) |
- |
500 |
|
- |
| Cl-6.1.3, Table- 4 (iv)(Flexing resistance, Flexes) |
- |
800 |
|
- |
| Cl-6.1.3, Table- 4 (v)(Water vapour permeability (WVP), mg/cm2 /h, Min) |
- |
1000 |
|
- |
| Cl-6.1.3, Table- 4 (vi)(Hydrolysis resistance) |
- |
2000 |
|
- |
| Cl-6.1.3, Table- 4 (vii)(Abrasion resistance) |
- |
800 |
|
- |
| Cl-6.1.4, Table-5 (i)(Colour fastness to light, Marring, Min) |
- |
1500 |
|
- |
| Cl-6.1.4, Table- 5 (ii)(Flexing resistance, flexes at (-) 5 ºC, s 25 000 flexes) |
- |
700 |
|
- |
| Cl-6.2, Table-6 (i)(Tear strength, N, Min) |
- |
500 |
|
- |
| Cl-6.2, Table-6 (ii)(Abrasion resistance) |
- |
1000 |
|
- |
| Cl-6.2, Table-6 (iii)(Colour fastness rubbing (crocking)) |
- |
500 |
|
- |
| Cl-6.2, Table-6 (iv)(Colour fastness to perspiration) |
- |
500 |
|
- |
| Cl-6.2, Table-6 (v)(Water vapour permeability, mg/cm2 /h, Min Water vapour coefficient, mg/cm2, Min) |
- |
800 |
|
- |
| Cl-6.3, Table-7 (ii)(Abrasion resistance at 400 cycles) |
- |
500 |
|
- |
| Cl-6.3, Table-7 (iii)(Water absorption, mg/cm2 , Min
Water desorption, percent, Min) |
- |
500 |
|
- |
| Cl-6.4, Table-8 (i)(Thickness, mm, Min) |
- |
300 |
|
- |
| Cl-6.4, Table-8 (ii)(Abrasion resistance) |
- |
800 |
|
- |
| Cl-6.4, Table-8 (iii)(Water absorption, mg/cm2 , Min
Water desorption, percent, Min) |
- |
500 |
|
- |
| Cl-6.5.1, , Table-9 (i)(Flexing resistance) |
- |
500 |
|
- |
| Cl-6.5.1, , Table-9 (ii)(Hydrolysis resistance, cut growth at 150 000 flexes, mm, Max) |
- |
2000 |
|
- |
| Cl-6.5.1, , Table-9 (iii)(Compression set, percent, Max) |
- |
800 |
|
- |
| Cl-6.5.2.1, Table-10 (i)(Grain crack index, Min) |
- |
500 |
|
- |
| Cl-6.5.2.1, Table-10 (ii)(Density, g/cm3 , Min) |
- |
300 |
|
- |
| Cl-6.5.2.2, Table-11 (i)(Water resistance, (dynamic method)) |
- |
800 |
|
- |
| Cl-6.5.2.3, Table-12 (i)(Hardness, Min) |
- |
300 |
|
- |
| Cl-6.5.2.3, Table-12 (ii)(Density, g/cm3 , Max) |
- |
300 |
|
- |
| Cl-6.5.2.3, Table-12 (iii)(Abrasion resistance (volume loss), mm3 , Max) |
- |
800 |
|
- |
| Cl-6.5.2.3, Table-12 (iv)(Bond Strength between Rubber top-lift and adjacent material, N/mm, Min) |
- |
500 |
|
- |
| Cl-6.6, Table-13 (i)(Heat shrinkage, percent, Max) |
- |
500 |
|
- |
| Cl-6.6, Table-13 (ii)(Split tear strength, kg/25 mm, Min) |
- |
500 |
|
- |
| Cl-6.6, Table-13 (iii)(Compression set, percent, Max) |
- |
800 |
|
- |
| Cl-6.7, Table-14 (i)(Hardness, N) |
- |
300 |
|
- |
| Cl-6.7, Table-14 (ii)(Resilience, percent) |
- |
800 |
|
- |
| Cl-6.7, Table-14 (iii)(Moisture resistance, percent) |
- |
500 |
|
- |
| Cl-6.10, Table-17 (i)(Lace breaking strength, N, Min) |
- |
500 |
|
- |
| Cl-6.10, Table-17 (ii)(Lace tag strength, N, Min) |
- |
500 |
|
- |
| Cl-6.10, Table-17 (iii)(Lace to lace abrasion resistance, cycles) |
- |
500 |
|
- |
| Cl-6.10, Table-17 (iv)(Colour fastness to water for lace contact methodstaining Gray scale rate , Min) |
- |
500 |
|
- |
| Cl-6.10, Table-17 (v)(Corrosion resistance) |
- |
500 |
|
- |
| Cl-6.11, Table-18 (i)(Fatigue resistance, cycles, Min) |
- |
500 |
|
- |
| Cl-6.11, Table-18 (ii)(Security of puller attachment strength, N, Min) |
- |
500 |
|
- |
| Cl-6.11, Table-18 (iii)(Lateral load, N, Min) |
- |
1000 |
|
- |
| Cl-6.11, Table-18 (iv)(End attachment strength, N, Min) |
- |
500 |
|
- |
| Cl-8.1(Marking) |
- |
300 |
|
- |
| Cl-6.7, Table-14 (iv)(Area shape retention, percent
(a) Initial, Min
b) After 10 collapsing load, Min) |
- |
500 |
|
- |
| Cl-6.7, Table-14 (v)(Adhesion strength, N/mm) |
- |
500 |
|
- |
| Cl-6.8, Table-15 (i)(Peel strength, N/mm
a) Initial, Min
b) After 5 000 wear cycles, Min) |
- |
500 |
|
- |
| Cl- 6.8, Table-15 (ii)(a) Shear strength, kPa
b) Initial, Min) |
- |
500 |
|
- |
| Cl- 6.9, Table-16 (i)(Limit of useful extension, percent,
Min) |
- |
500 |
|
- |
| Cl- 6.9, Table-16 (ii)(Needle strength, N/mm, Min) |
- |
500 |
|
- |
| Cl-5.1(Shape and Design) |
- |
300 |
|
- |
| Cl-5.3(Material) |
- |
300 |
|
- |
| Cl-5.4, Table-1 (i)(Bond strength, N/mm, Min Upper to outsole, N/mm, Min) |
- |
500 |
|
- |
| Cl-5.4, Table-1 (ii)(Inter layer bond strength,= N/mm, Min Midsole to outsole, N/mm, Min) |
- |
500 |
|
- |
| Cl-5.4, Table-1 (iii)(Whole shoe flexing, flexes) |
- |
1500 |
|
- |
| Cl-5.4, Table-1 (iv)(Water proofness on complete shoe) |
- |
1500 |
|
- |
| Cl-5.4, Table-1 (v)(Slip resistance, Cof(1), Min dry and wet* (quarry tile)) |
- |
1500 |
|
- |
| Cl-5.4, Table-1 (vi)(Attachment strength of strap and buckle/D-ring N) |
- |
500 |
|
- |
| Cl-5.4, Table-1 (vii)(Attachment strength of strap and velcro , N, Min) |
- |
500 |
|
- |
| Cl-5.4, Table-1 (viii)(Strength of eyelet attachment, N, Min) |
- |
500 |
|
- |
| Cl-5.4, Table-1 (ix)(Heel pull off strength, N, Min) |
- |
500 |
|
- |
| Cl-5.4, Table-1 (x)(Top piece attachment strength, N, Min) |
- |
500 |
|
- |
| Cl-5.4, Table-1 (xi)(Seam strength, N/mm, Min) |
- |
500 |
|
- |
| Cl-5.4, Table-1 (xii)(Whole shoe topline strength, N, Min) |
- |
1500 |
|
- |
| Cl-5.4, Table-1 (xiii)(Abrasion resistance (volume loss), mm3) |
- |
800 |
|
- |
| Cl-5.4, Table-1 (xiv)(Chemical requirements(3)) |
- |
30000 |
|
- |
| Cl-5.4, Table-1 (xv)(Lead content (as Pb) ppm, Max) |
- |
1000 |
|
- |
| Cl-5.4, Table-1 (xvi)(Hydrolysis resistance,(4) cut growth at 150 000 flexes, mm, Max) |
- |
1500 |
|
- |
| Cl-6.1.1, Table-2 (i)(Tear trength, N) |
- |
500 |
|
- |
| Cl-6.1.1, Table-2 (ii)(Flexing resistance, flexes) |
- |
1500 |
|
- |
| Cl-6.1.1, Table-2 (iii)(Colour fastness to rubbing (marring/staining)) |
- |
800 |
|
- |
| Cl-6.1.1, Table-2 (iv)(Colour fastness to water (contact method- multi fabrics)) |
- |
800 |
|
- |
| Cl-6.1.1, Table-2 (v)(Water vapour permeability,mg/cm2 /h, Min Water vapour coefficient,mg/cm2 , Min) |
- |
500 |
|
- |
| Cl-6.1.1, Table-2 (vi)(Stitch tear strength, N/mm, Min) |
- |
500 |
|
- |
| Cl-6.1.1, Table-2 (vii)(Abrasion resistance) |
- |
800 |
|
- |
| Cl-6.1.2, Table-3 (i)(Colour fastness to light, Marring, Min) |
- |
800 |
|
- |
| Cl-6.1.2, Table-3 (ii)(Water resistance) |
- |
1000 |
|
- |
| Cl-6.1.2, Table-3 (iii)(Flexing resistance, flexes at (-) 5 °C 25 000 flexes) |
- |
800 |
|
- |
| Cl-6.1.3, Table- 4 (i)(Breaking strength, N/mm, Min Elongation at break, percent, Min) |
- |
500 |
|
- |
| Cl-6.1.3, Table- 4 (ii)(Tear Strength, N, Min) |
- |
500 |
|
- |
| Cl-6.1.3, Table- 4 (iii)(Strength at needle perforation, N/mm, Min) |
- |
500 |
|
- |
| Cl-6.1.3, Table- 4 (iv)(Flexing resistance, Flexes) |
- |
800 |
|
- |
| Cl-6.1.3, Table- 4 (v)(Water vapour permeability (WVP), mg/cm2 /h, Min) |
- |
800 |
|
- |
| Cl-6.1.3, Table- 4 (vi)(Hydrolysis resistance) |
- |
1500 |
|
- |
| Cl-6.1.3, Table- 4 (vii)(Abrasion resistance) |
- |
800 |
|
- |
| Cl-6.1.4, Table-5 (i)(Colour fastness to light, Marring, Min) |
- |
500 |
|
- |
| Cl-6.1.4, Table- 5 (ii)(Flexing resistance, flexes at (-) 5 ºC, s 25 000 flexes) |
- |
800 |
|
- |
| Cl-6.2, Table-6 (i)(Tear strength, N, Min) |
- |
500 |
|
- |
| Cl-6.2, Table-6 (ii)(Abrasion resistance) |
- |
800 |
|
- |
| Cl-6.2, Table-6 (iii)(Colour fastness rubbing (crocking)) |
- |
500 |
|
- |
| Cl-6.2, Table-6 (iv)(Colour fastness to perspiration) |
- |
500 |
|
- |
| Cl-6.2, Table-6 (v)(Water vapour permeability, mg/cm2 /h, Min Water vapour coefficient, mg/cm2, Min) |
- |
500 |
|
- |
| Cl-6.3, Table-7 (ii)(Abrasion resistance at 400 cycles) |
- |
800 |
|
- |
| Cl-6.3, Table-7 (iii)(Water absorption, mg/cm2 , Min
Water desorption, percent, Min) |
- |
500 |
|
- |
| Cl-6.4, Table-8 (i)(Thickness, mm, Min) |
- |
300 |
|
- |
| Cl-6.4, Table-8 (ii)(Abrasion resistance) |
- |
800 |
|
- |
| Cl-6.4, Table-8 (iii)(Water absorption, mg/cm2 , Min
Water desorption, percent, Min) |
- |
500 |
|
- |
| Cl-6.5.1, , Table-9 (i)(Flexing resistance) |
- |
1500 |
|
- |
| Cl-6.5.1, , Table-9 (ii)(Hydrolysis resistance, cut growth at 150 000 flexes, mm, Max) |
- |
1500 |
|
- |
| Cl-6.5.1, , Table-9 (iii)(Compression set, percent, Max) |
- |
1000 |
|
- |
| Cl-6.5.2.1, Table-10 (i)(Grain crack index, Min) |
- |
300 |
|
- |
| Cl-6.5.2.1, Table-10 (ii)(Density, g/cm3 , Min) |
- |
300 |
|
- |
| Cl-6.5.2.2, Table-11 (i)(Water resistance, (dynamic method)) |
- |
800 |
|
- |
| Cl-6.5.2.3, Table-12 (i)(Hardness, Min) |
- |
300 |
|
- |
| Cl-6.5.2.3, Table-12 (ii)(Density, g/cm3 , Max) |
- |
300 |
|
- |
| Cl-6.5.2.3, Table-12 (iii)(Abrasion resistance (volume loss), mm3 , Max) |
- |
800 |
|
- |
| Cl-6.5.2.3, Table-12 (iv)(Bond Strength between Rubber top-lift and adjacent material, N/mm, Min) |
- |
500 |
|
- |
| Cl-6.6, Table-13 (i)(Heat shrinkage, percent, Max) |
- |
800 |
|
- |
| Cl-6.6, Table-13 (ii)(Split tear strength, kg/25 mm, Min) |
- |
500 |
|
- |
| Cl-6.6, Table-13 (iii)(Compression set, percent, Max) |
- |
500 |
|
- |
| Cl-6.7, Table-14 (i)(Hardness, N) |
- |
300 |
|
- |
| Cl-6.7, Table-14 (ii)(Resilience, percent) |
- |
500 |
|
- |
| Cl-6.7, Table-14 (iii)(Moisture resistance, percent) |
- |
500 |
|
- |
| Cl-6.10, Table-17 (i)(Lace breaking strength, N, Min) |
- |
500 |
|
- |
| Cl-6.10, Table-17 (ii)(Lace tag strength, N, Min) |
- |
500 |
|
- |
| Cl-6.10, Table-17 (iii)(Lace to lace abrasion resistance, cycles) |
- |
800 |
|
- |
| Cl-6.10, Table-17 (iv)(Colour fastness to water for lace contact methodstaining Gray scale rate , Min) |
- |
500 |
|
- |
| Cl-6.10, Table-17 (v)(Corrosion resistance) |
- |
800 |
|
- |
| Cl-6.11, Table-18 (i)(Fatigue resistance, cycles, Min) |
- |
500 |
|
- |
| Cl-6.11, Table-18 (ii)(Security of puller attachment strength, N, Min) |
- |
500 |
|
- |
| Cl-6.11, Table-18 (iii)(Lateral load, N, Min) |
- |
800 |
|
- |
| Cl-6.11, Table-18 (iv)(End attachment strength, N, Min) |
- |
500 |
|
- |
| Cl-8.1(Marking) |
- |
300 |
|
- |
| Cl-6.7, Table-14 (iv)(Area shape retention, percent
(a) Initial, Min
b) After 10 collapsing load, Min) |
- |
500 |
|
- |
| Cl-6.7, Table-14 (v)(Adhesion strength, N/mm) |
- |
500 |
|
- |
| Cl-6.8, Table-15 (i)(Peel strength, N/mm
a) Initial, Min
b) After 5 000 wear cycles, Min) |
- |
500 |
|
- |
| Cl- 6.8, Table-15 (ii)(a) Shear strength, kPa
b) Initial, Min) |
- |
500 |
|
- |
| Cl- 6.9, Table-16 (i)(Limit of useful extension, percent,
Min) |
- |
500 |
|
- |
| Cl- 6.9, Table-16 (ii)(Needle strength, N/mm, Min) |
- |
800 |
|
- |
| Cl-6.3, Table-7 (i)(Flexing index, Min) |
- |
1500 |
|
- |
| Cl-6.5.2.1, Table-10 (iii)(Abrasion resistance, mm/kcs, Max) |
- |
800 |
|
- |
| CL. 5.4, Table 1, Sl No (xiv) & Table 1 of IS 17011(pH, Min) |
- |
500 |
|
- |
| CL. 5.4, Table 1, Sl No (xv)("Lead content (as Pb) ppm, Max
(applicable only for PVC") |
- |
1000 |
|
- |
|
15 Apr, 2027 |
- Included w.e.f.29.11.2024 |
| 6899 |
Ahmedabad Textile Industry's Research Association (ATIRA), Ahmedabad
| 7173002
| IS 17070 (2019) |
Jute agrotextiles for growth of plant and suppression of weeds – Specification |
- |
7900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5 -Table 1 -(i)(Mass at 20 percent moisture regain) |
- |
800 |
|
- |
| 5 -Table 1 -(ii)(Thickness) |
- |
450 |
|
- |
| 5 -Table 1 -(iii)(Width) |
- |
200 |
|
- |
| 5 -Table 1 -(iv)(Wide width tensile strength) |
- |
1650 |
|
- |
| 5 -Table 1 -(v)(Tear strength) |
- |
900 |
|
- |
| 5 -Table 1 -(vi)(Bursting strength) |
- |
800 |
|
- |
| 5 -Table 1 -(vii)(Index Puncture resistance) |
- |
1350 |
|
- |
| 5 -Table 1 -(viii)(Air permeability) |
- |
650 |
|
- |
| 5-Table 1 -(ix)(Water permittivity) |
- |
1100 |
|
- |
|
- |
- Included w.e.f 10.10.2024
Excluding Cl 8 (Marking) |
| 6900 |
DELHI TEST HOUSE, Azadhpur
| 8131406
| IS 210 (2009) |
Grey iron castings - Specification (First Revision) |
- |
9000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.1(FREEDOM FROM DEFECTS) |
- |
500 |
|
TESTING CHARGES :-Rs.9000/- |
| 10.2(FREEDOM FROM DEFECTS) |
- |
500 |
|
TESTING CHARGES :-Rs.9000/- |
| 15, Table 3(TENSIL.E TEST- IS 1608 Part1 ) |
- |
2000 |
|
TESTING CHARGES :-Rs.9000/- |
| 16, Table 3(Hardness Test) |
- |
1000 |
|
TESTING CHARGES :-Rs.9000/- |
| 6(Chemical Composition(chemical
composition shall be as agreed to between the
purchaser and the manufacturer.)) |
- |
5500 |
|
TESTING CHARGES :-Rs.9000/- |
| 10.1(FREEDOM FROM DEFECTS) |
- |
500 |
|
TESTING CHARGES :-Rs.9000/- |
| 10.2(FREEDOM FROM DEFECTS) |
- |
500 |
|
TESTING CHARGES :-Rs.9000/- |
| 15, Table 3(TENSIL.E TEST- IS 1608 Part1 ) |
- |
2000 |
|
TESTING CHARGES :-Rs.9000/- |
| 16, Table 3(Hardness Test) |
- |
1000 |
|
TESTING CHARGES :-Rs.9000/- |
| 21(Marking) |
- |
250 |
|
TESTING CHARGES :-Rs.9000/- |
| 6(Chemical Composition(chemical
composition shall be as agreed to between the
purchaser and the manufacturer.)) |
- |
5500 |
|
TESTING CHARGES :-Rs.9000/- |
|
17 Jun, 2027 |
- Included w.e.f 15.10.2024