| 14131 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 2465 (1984) |
Specification for cables for motor vehicles (Second Revision) |
- |
Single core PVC Insulated Unsheathed: Rs. 11030/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1 (Insulation) |
- |
|
|
|
| 7.3 (Insulation) |
- |
|
|
|
| 8 (Core Identification) |
- |
|
|
|
| 9 (Laying up of cores) |
- |
|
|
|
| 10.1.1 (Sheathing ) |
- |
|
|
|
| 10.2 (Sheathing ) |
- |
|
|
|
| 3 & 6 (Flexibility class) |
- |
|
|
|
| 3 & 6 (Construction) |
- |
|
|
|
| 3 & 6 (Diameter of wire(mm)) |
- |
|
|
|
| 3 & 6 (Annealing test) |
- |
|
|
|
| 3 & 6 (Persulphate Test) |
- |
|
|
|
| 3 & 6 (Conductor resistance Test (ohm/km at 20˚c)) |
- |
|
|
|
| 7.2, 10.3, 11 (Dimensions & thickness ) |
- |
|
|
|
| 7.2, 10.3, 11 (Dimensions & thickness ) |
- |
|
|
|
| 7.2, 10.3, 11 (Overall Dimension (mm)) |
- |
|
|
|
| 4.2 & 12.1 (Without Ageing For Insulation
Tensile Strength (N/mm²)) |
- |
|
|
|
| 4.2 & 12.1, (f), 1 (elongation at break (N/mm²)) |
- |
|
|
|
| 4.2 & 12.1, (f), 1 (Tensile Strength at break (N/mm²)) |
- |
|
|
|
| 4.2 & 12.1, (e), 1 (elongation test at break) |
- |
|
|
|
| 4.2 & 12.1, (e), 1 (Tensile strength at break) |
- |
|
|
|
| 4.2 & 12.1, (f), 2 (Ageing in air oven) |
- |
|
|
|
| 4.2 & 12.1, (f), 3 (Ageing in oxygen bomb) |
- |
|
|
|
| 4.2 & 12.1, (e), 2 (After Ageing in air oven) |
- |
|
|
|
| 4.2 & 12.1, (e), 3 (Loss of mass test (mg/cm²) of Insulation) |
- |
|
|
|
| 4.2 & 12.1, (e), 3 (Loss of mass test (mg/cm²) of Sheath) |
- |
|
|
|
| 4.2 & 12.1, (e), 4 (Hot deformation test (%) of Insulation) |
- |
|
|
|
| 4.2 & 12.1, (e), 4 (Hot deformation test (%) of Sheath) |
- |
|
|
|
| 4.2 & 12.1, (e), 5 (Heat Shock Test of Insulation) |
- |
|
|
|
| 4.2 & 12.1, (e), 5 (Heat Shock Test of Sheath) |
- |
|
|
|
| 4.2 & 12.1, (e), 6 (Shrinkage Test (%) of Insulation) |
- |
|
|
|
| 4.2 & 12.1, (e), 6 (Shrinkage Test (%) of Sheath) |
- |
|
|
|
| 14 (High Voltage Test) |
- |
|
|
|
| 22.1 (FLAMMABILITY TEST) |
- |
|
|
|
| 22.1 (FLAMMABILITY TEST) |
- |
|
|
|
| 23.1 (Manufacturer's Identification) |
- |
|
|
|
| 23.1 (Manufacturer's Identification) |
- |
|
|
|
| 24.1 (PACKING AND MARKING) |
- |
|
|
|
| 24.2 (PACKING AND MARKING) |
- |
|
|
|
| 24.2.1 (PACKING AND MARKING) |
- |
|
|
|
|
- |
- "Complete for general wiring only & Partial for PVC Insulation ignition cable
Excluding Cl. 16 capacitance, Cl. 18 Effect of heat on flexibility" |
| 14132 |
BIS, Central Laboratory (CL)
| None
| IS 4151 (1993.0) |
Protective helmets for motorcycle riders - Specification |
- |
testing charges for the product are Rs. 27300/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Shell) |
- |
|
|
|
| 4.5 (Metal Parts) |
- |
|
|
|
| 6.1 (General) |
- |
|
|
|
| 6.2 (Shell) |
- |
|
|
|
| 6.3 (Protactive Padding) |
- |
|
|
|
| 6.4 (Retention System) |
- |
|
|
|
| 6.7 (Peripheral Vision) |
- |
|
|
|
| 6.8 (Workmanship and Finish) |
- |
|
|
|
| 7.2 (Impact Absorption Test) |
- |
|
|
|
| 7.3 (Rigidity Test) |
- |
|
|
|
| 7.4 (Projections and Surface Friction Test) |
- |
|
|
|
| 7.5 (Dynamic Test of Retention System) |
- |
|
|
|
| 7.6 (Audibility Test) |
- |
|
|
|
| 7.7 (Retention Test of Helmet) |
- |
|
|
|
| 7.8 (Micro-Slip Test of the Chin Strap) |
- |
|
|
|
| 7.9 (Test for Resistance to Abrasion of the Chin Strap ) |
- |
|
|
|
| 7.10.2 (Ease of Release) |
- |
|
|
|
| 7.10.3 (Durability of Quick Release Mechanism) |
- |
|
|
|
|
- |
- IS superseded by newer version; |
| 14133 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 1038 (1983) |
Specification For Steel Doors, Windows And Ventilators |
- |
3000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1. (Size-Height) |
- |
|
|
|
| 4.1 (Size-Width) |
- |
|
|
|
| 4.1. (Size-Height) |
- |
|
|
|
| 4.1 (Size-Width) |
- |
|
|
|
| 4.1. (Size-Height) |
- |
|
|
|
| 4.1 (Size-Width) |
- |
|
|
|
| 4.3 (Designation) |
- |
|
|
|
| 6.1.1.1 (Visual Inspection Test) |
- |
|
|
|
| 6.2 (Side Hung Shutter- Thickness of hinge) |
- |
|
|
|
| 6.2 (Side Hung Shutter- Pin diameter) |
- |
|
|
|
| 6.2 (Side Hung Shutter) |
- |
|
|
|
| 6.2 (Side Hung Shutter-Width of hinge) |
- |
|
|
|
| 6.2.2 & 6.2.2.1 (Handle and Handle Plate-Material of handel ) |
- |
|
|
|
| 6.2.2 & 6.2.2.1 (Handle and Handle Plate- Thicknesss of handle) |
- |
|
|
|
| 6.2.2 & 6.2.2.1 (Handle and Handle Plate-Height of handle plate) |
- |
|
|
|
| 6.2.3 (Peg Stay - Material) |
- |
|
|
|
| 6.2.3 (Peg Stay - Thickness) |
- |
|
|
|
| 6.2.3 (Peg Stay ) |
- |
|
|
|
| 6.3 (Top Hung Ventilator) |
- |
|
|
|
| 6.3 (Top Hung Ventilator-Thickness of hinge) |
- |
|
|
|
| 6.3 (Top Hung Ventilator-Pin diameter) |
- |
|
|
|
| 6.3 (Top Hung Ventilator-Width of hinge) |
- |
|
|
|
| 7.1 (Position of Holes) |
- |
|
|
|
| 7.2 Table 2 (Position of Fixing Screws) |
- |
|
|
|
| 7.2 Table 2 (Lugs-A) |
- |
|
|
|
| 7.2 Table 2 (Lugs-B) |
- |
|
|
|
| 7.2 Table 2 (Lugs-C) |
- |
|
|
|
| 7.2 Table 2 (Lugs-D) |
- |
|
|
|
| 7.2 Table 2 (Lugs-E) |
- |
|
|
|
| 6.2.3 (Peg Stay - Dimensions-F) |
- |
|
|
|
| 7.2 Table 2 (Lugs-G) |
- |
|
|
|
| 8 (Finish) |
- |
|
|
|
| 9 (Glazing) |
- |
|
|
|
|
- |
- " 1+1 NO.
Excluding Excl. micro and macro examination & Fillet weld test |
| 14134 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 4308 (2019) |
Dry Chemical Powders for Fire Fighting — BC, ABC and D Types — Specification ( Third Revision ) |
- |
Rs 5770/- for both ordinary type & foam compatible type View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 5 Table 1(iii) (Apparent density (Declared value by
the manufacturer)) |
- |
|
|
|
| Clause 5 Table 1(iv) (Particle size / sieve analysis (Declared value by
the manufacturer)) |
- |
|
|
|
| Clause 5 Table 1(vi) (Water repellency) |
- |
|
|
|
| Clause 5 Table 1(vii) (Moisture content) |
- |
|
|
|
| Clause 5 Table 1(xii) (colour) |
- |
|
|
|
|
- |
- " 5 kg
Excluding Rate of flow, Foam compatibility, Fire Test, Temperature Resistance Test , chemical constituents |
| 14135 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 5175 (2014) |
Fibre ropes – Polypropylene split film, monofilament and multifilament (PP2) and polypropylene high- tenacity multifilament (PP3) – 3-, 4-, 8- and 12-strand ropes (third revision) |
- |
6300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 4( Designation) |
- |
0 |
|
Nil |
| Cl 5(General Requirements) |
- |
3950 |
|
Nil |
| Cl 6 & Table 1,2 or 3(Reference Number.) |
- |
750 |
|
Nil |
| Cl 6 & Table 1,2 or 3(Linear Density) |
- |
500 |
|
Nil |
| Cl 6 & Table 1,2 or 3(Breaking Force) |
- |
1100 |
|
Nil |
|
31 Dec, 2026 |
- - |
| 14136 |
MSME TESTING CENTRE (WR), MUMBAI
| 7119404
| IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
PVC insulated unsheathed & sheathed cables/cords 110V |
22000 View breakup
Type test ₹12000 Singlecore/Unsheathed/01,₹16000
Singlecore/Sheathed/01,₹20000 Singlecore/Unsheathed/FR,₹22000
Singlecore/Sheathed/FR; Multicore: 25% extra for each additional core on single
core rate, Cat.02 ₹5000/- extra
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Tensile test (for Al)- After Stranding) |
- |
1800 |
|
Type test: i)Single core/Unsheathed/01:Rs.12,000/-, ii) Single core/sheathed/01:Rs.16000/- , iii)Single core/Unsheathed/FR:Rs.18000/-, iv)Single core/sheathed/FR:Rs.22000/- |
| 4.1(Tensile test (for Al)-Before Stranding) |
- |
1800 |
|
Acceptance test: i)Single core/Unsheathed/01:Rs.9,000/-, ii) Single core/sheathed/01:Rs.12000/- , iii)Single core/Unsheathed/FR:Rs.13500/-, iv)Single core/sheathed/FR:Rs.16500/- |
| 4.1(Annealing test (for copper)) |
- |
1800 |
|
For Multicore cables:25%extra for each additional core on single core rate |
| 4.1(Wrapping test (for Al)) |
- |
1500 |
|
- |
| 4.2(Conductor resistance test) |
- |
1800 |
|
- |
| Table 1(Category Code) |
- |
5000 |
|
For Cat.02 Rs.5000/- additional on above test charge |
| table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
1800 |
|
1800 |
| table 1 e) 3) (IR constant- Room temp ) |
- |
1800 |
|
1800 |
| table 1 e) 3) (IR constant- max. Temp) |
- |
1800 |
|
1800 |
| 5.1(Insulation) |
- |
2000 |
|
2000 |
| Table 1 iii) d) 7)(Thermal stability- Sheath ) |
- |
1800 |
|
1800 |
| Table 1 iii) d) 4)(Shrinkage- Sheath ) |
- |
3500 |
|
3500 |
| Table 1 iii) c) 5)(Heat shock-Insulation ) |
- |
1800 |
|
1800 |
| Table 1 iii) d) 6)(Hot deformation -Indentation depth - Sheath ) |
- |
2000 |
|
2000 |
| Table 1 iii) d) 8)(Cold bend for sheath) |
- |
3500 |
|
3500 |
| Table 1 iii) d) 9)(Cold impact for sheath) |
- |
3500 |
|
3500 |
| 10.4(Flammability test- Unaffected portion) |
- |
1800 |
|
1800 |
| 10.5(Oxygen index) |
- |
3500 |
|
3500 |
| 10.7(Temperature index) |
- |
3500 |
|
3500 |
| Table 1 iii) d) 2)(Loss of mass- Sheath ) |
- |
3000 |
|
3000 |
| Table 1 iii) d) 3)(Sheath- TS variation) |
- |
2000 |
|
2000 |
| Table 1 iii) c) 4)(Shrinkage-Insulation) |
- |
3500 |
|
3500 |
| Table 1 iii) d) 5)(Heat shock-Sheath ) |
- |
1800 |
|
1800 |
| 10.1(HV (water immersion)) |
- |
4000 |
|
4000 |
| 10.2(HV (room temperature)) |
- |
1800 |
|
1800 |
| 10.9(Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
5000 |
|
5000 |
|
- |
- - |
| 14137 |
MSME TESTING CENTRE (WR), MUMBAI
| 7119404
| IS 4250 (1980) |
Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) |
Domestic Electric Food Mixers (Liquidizers & Grinders) |
16000 View breakup
Type test: Rs. 16,000/- ; Acceptance test Rs. 12,000/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Marking- IS 302-1) |
- |
1800 |
|
1800 |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
1800 |
|
1800 |
| 9(Starting, IS 302-1) |
- |
1800 |
|
1800 |
| 10(Power Input and Current, IS 302-1) |
- |
1800 |
|
1800 |
| 11(Heating, IS 302-1) |
- |
2500 |
|
2500 |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1800 |
|
1800 |
| 15.1(Moisture Resistance, IS 302-1) |
- |
3000 |
|
3000 |
| 15.2(Moisture Resistance-Spillage test) |
- |
3000 |
|
3000 |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1800 |
|
1800 |
| 19(Abnormal Operation, IS 302-1) |
- |
1800 |
|
1800 |
| 21(Mechanical Strength, IS 302-1) |
- |
1800 |
|
1800 |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1800 |
|
1800 |
| 27(Provision for Earthing, IS 302-1) |
- |
1800 |
|
1800 |
| 28(Screws & Connections, IS 302-1) |
- |
1800 |
|
1800 |
| 29(Clearances and Distances through Insulation, IS 302-1) |
- |
1800 |
|
1800 |
| 30(Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
3000 |
|
3000 |
| 34.2(Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
2500 |
|
2500 |
| 34.3(Whisking egg whites ) |
- |
2500 |
|
2500 |
| 35(Temperature withstand test for bowl) |
- |
1500 |
|
1500 |
| 36(Test for controls ) |
- |
1800 |
|
1800 |
|
- |
- Type Test: Rs.14,000/-
Acceptance Test: Rs.10,500/- |
| 14138 |
MSME TESTING CENTRE (WR), MUMBAI
| 7119404
| IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
Self ballasted LED Lamps for general lighting service |
20000 View breakup
Type test Rs. 20,000/- ; Acceptance test Rs. 15,000/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
1800 |
|
1800 |
| 6(Interchangeability) |
- |
1800 |
|
1800 |
| 7(Protection against accidental contact with live parts) |
- |
1800 |
|
1800 |
| 8(Insulation Resistance and Electric Strength) |
- |
6000 |
|
6000 |
| 9(MECHANICAL STRENGTH) |
- |
2500 |
|
2500 |
| 10(cap temperature) |
- |
5000 |
|
5000 |
| 11(Resistance to Heat) |
- |
1800 |
|
1800 |
| 12(Resistance to Flame and Ignition) |
- |
2500 |
|
2500 |
| 13(Fault conditions) |
- |
1800 |
|
1800 |
| 14(Creepage distance and clearances) |
- |
1800 |
|
1800 |
|
- |
- Lamp Cap Type : B22d only |
| 14139 |
MSME TESTING CENTRE (WR), MUMBAI
| 7119404
| IS 1293 (2019) |
Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) |
upto & including 250V & rated current upto 16A |
22000 View breakup
Type test : Rs.14,000/- for 6/10A; Rs. 16,000/- for 16A; Rs. 22,000/- for 6A/16A
combined socket. Acceptance test: Rs.10,500/- for 6/10A; Rs. 16,000/- for 16A;
Rs. 15,000/- for 6A/16A combined socket.
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Ratings) |
- |
1800 |
|
Type Test:6A/10A:Rs.14000/-, 16A:Rs.16000/-, 6/16AMultiple Socket:Rs.20000/-
Acceptance Test:6A/10A:Rs.10500/-, 16A:Rs.12000/-, 6/16AMultiple Socket:Rs.15000/- |
| 7.1.1(Accessories Classification) |
- |
1800 |
|
Type Test:6A/10A:Rs.14000/-, 16A:Rs.16000/-, 6/16AMultiple Socket:Rs.20000/-
Acceptance Test:6A/10A:Rs.10500/-, 16A:Rs.12000/-, 6/16AMultiple Socket:Rs.15000/- |
| 7.1.2(Accessories Classification) |
- |
1800 |
|
1800 |
| 7.1.3(Accessories Classification) |
- |
1800 |
|
1800 |
| 7.1.4(Accessories Classification) |
- |
1800 |
|
1800 |
| 7.1.5(Accessories Classification) |
- |
1800 |
|
1800 |
| 7.2.1(Socket-Outlets Classification) |
- |
1800 |
|
1800 |
| 7.2.2(Socket-Outlets Classification) |
- |
1800 |
|
1800 |
| 7.2.3(Socket-Outlets Classification) |
- |
1800 |
|
1800 |
| 7.2.4(Socket-Outlets Classification) |
- |
1800 |
|
1800 |
| 7.3(Plug Classification) |
- |
1800 |
|
1800 |
| 8.1(MARKING) |
- |
1800 |
|
1800 |
| 8.8(MARKING) |
- |
1800 |
|
1800 |
| 8.9(MARKING) |
- |
1800 |
|
1800 |
| 9.1(CHECKING OF DIMENSIONS) |
- |
1800 |
|
1800 |
| 9.2(CHECKING OF DIMENSIONS) |
- |
1800 |
|
1800 |
| 10.1(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1800 |
|
1800 |
| 10.3(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1800 |
|
1800 |
| 10.4(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1800 |
|
1800 |
| 10.5(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1800 |
|
1800 |
| 10.6(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1800 |
|
1800 |
| 10.7(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1800 |
|
1800 |
| 11.1(PROVISIONS FOR EARTHING) |
- |
1800 |
|
1800 |
| 11.2(PROVISIONS FOR EARTHING) |
- |
1800 |
|
1800 |
| 11.3(PROVISIONS FOR EARTHING) |
- |
1800 |
|
1800 |
| 11.4(PROVISIONS FOR EARTHING) |
- |
1800 |
|
1800 |
| 11.5(PROVISIONS FOR EARTHING) |
- |
1800 |
|
1800 |
| 11.6(PROVISIONS FOR EARTHING) |
- |
1800 |
|
1800 |
| 12.1.1(TERMINALS) |
- |
2500 |
|
2500 |
| 12.1.2(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.1(TERMINALS) |
- |
2500 |
|
- |
| 12.2.2(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.3(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.4(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.5(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.6(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.7(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.8(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.9(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.10(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.11(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.1(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.2(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.4(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.5(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.6(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.7(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.8(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.9(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.10(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.11(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.12(TERMINALS) |
- |
2500 |
|
2500 |
| 13.1(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.2(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.3(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.4(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.5(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.6(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.7(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.8(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.9(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.11(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.12(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.13(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.14(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.15(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.16(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.17(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.18(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.19(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.21(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.22(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.23(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
2500 |
|
2500 |
| 14.26(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
2500 |
|
2500 |
| 15(INTERLOCKED SOCKET-OUTLETS) |
- |
2500 |
|
2500 |
| 16.1(RESISTANCE TO AGEING,) |
- |
3000 |
|
3000 |
| 16.2(RESISTANCE TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
3000 |
|
3000 |
| 16.3(Resistance to Humidity) |
- |
3000 |
|
3000 |
| 17.1(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
1800 |
|
1800 |
| 17.2(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
1800 |
|
1800 |
| 17.3(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
1800 |
|
1800 |
| 18(OPERATION OF EARTHING CONTACTS) |
- |
1800 |
|
1800 |
| 19(TEMPERATURE RISE) |
- |
2500 |
|
2500 |
| 20(BREAKING CAPACITY) |
- |
2000 |
|
2000 |
| 21(NORMAL OPERATION) |
- |
4000 |
|
4000 |
| 22.1(Verification of the Maximum Withdrawal Force) |
- |
1800 |
|
1800 |
| 22.2(Verification of Minimum Withdrawal Force) |
- |
1800 |
|
1800 |
| 23.1(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
1800 |
|
1800 |
| 23.3(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
1800 |
|
1800 |
| 24.1(MECHANICAL STRENGTH
For all kinds of fixed socket-outlets
) |
- |
1800 |
|
1800 |
| 24.2(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
1800 |
|
1800 |
| 24.3(MECHANICAL STRENGTH
for fixed socket-outlets with a main part intended to be mounted directly on a surface) |
- |
1800 |
|
1800 |
| 24.4(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
1800 |
|
1800 |
| 24.5(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
1800 |
|
1800 |
| 24.6(MECHANICAL STRENGTH
For screwed glands of accessories having an IP code higher than IP20) |
- |
1800 |
|
1800 |
| 25.1(RESISTANCE TO HEAT
Accessories and surface mounting boxes) |
- |
2500 |
|
2500 |
| 25.2(RESISTANCE TO HEAT
Parts of insulating material necessary to retain
current-carrying parts of the earthing circuit in position,
as well as parts of the front surface zone of thermoplastic material) |
- |
2500 |
|
2500 |
| 25.3(RESISTANCE TO HEAT
Parts of insulating material not necessary to retain current-carrying parts and parts of the earthing circuit in position, even though they are in contact with them) |
- |
2500 |
|
2500 |
| 25.4(RESISTANCE TO HEAT
) |
- |
2500 |
|
2500 |
| 25.1(RESISTANCE TO HEAT
Accessories and surface mounting boxes) |
- |
2500 |
|
2500 |
| 26.1(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
1800 |
|
1800 |
| 26.2(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
1800 |
|
1800 |
| 27.1(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
1800 |
|
1800 |
| 27.2(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
1800 |
|
1800 |
| 28.1.1(Resistance to Abnormal Heat and to Fire
Glow-Wire Test) |
- |
2500 |
|
2500 |
| 28.1.2(Resistance to Abnormal Heat and to Fire
for plugs with pins provided with insulating sleeves) |
- |
2500 |
|
2500 |
| 28.2(Resistance to Tracking
For accessories other than IP code higher than IPX0 parts of insulating material retaining live parts in position) |
- |
2500 |
|
2500 |
| 29(RESISTANCE TO RUSTING) |
- |
1800 |
|
1800 |
| 30.1(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Pressure Test at High Temperature) |
- |
1800 |
|
1800 |
| 30.2(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Static Damp Heat Test) |
- |
1800 |
|
1800 |
| 30.3(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Tests at Low Temperature) |
- |
1800 |
|
1800 |
| 30.4(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Impact Test at Low Temperature) |
- |
1800 |
|
1800 |
|
- |
- - |
| 14140 |
MSME TESTING CENTRE (WR), MUMBAI
| 7119404
| IS 14927 : Part 2 (2001) |
Cable Trunking and Ducting Systems for Electrical Installations : Part 2 Cable Trunking and Ducting Systems Intended for Mounting on Walls or Ceiling |
1 |
12000 View breakup
Rs 12,000 For complete IS
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Marking (as per Cl 7.1 of IS:14927(Pt-I ):2001)) |
- |
1000 |
|
1000 |
| 7.2(Marking (as per Cl 7.2 of IS:14927(Pt-I ):2001)) |
- |
1000 |
|
1000 |
| 8.1( Dimensions (As per cl.8.1 of IS 14927(Pt-1) : 2001)) |
- |
1000 |
|
1000 |
| 8.2(Dimensions (As per cl.8.2 of IS 14927(Pt-1) : 2001) |
- |
1000 |
|
1000 |
| 8.3, table 2( Dimensions (As per cl.8.3 and Table-2 of IS 14927(Pt-1) : 2001)) |
- |
1000 |
|
1000 |
| 9.1(Construction) |
- |
2000 |
|
2000 |
| 9.2(Construction ( As per Cl. 9.2 of IS 14927(Pt-1):2001)) |
- |
2000 |
|
2000 |
| 9.3(Construction ( As per Cl. 9.3 of IS 14927(Pt-1):2001)) |
- |
2000 |
|
2000 |
| 9.4.1(Construction [Access to Live Parts (As per Cl. 9.4.1 of IS 14927(Pt-1):2001)]) |
- |
2000 |
|
2000 |
| 9.5(Construction (As per Cl. 9.5 of IS 14927(Pt-1):2001)) |
- |
2000 |
|
2000 |
| 9.6.2(Construction [Membranes (As per Cl.9.6.2 of IS: 14927 (Pt-1):2001)]) |
- |
2000 |
|
2000 |
| 9.6.4(Construction [Membranes (As per Cl.9.6.4 of IS: 14927 (Pt-1):2001)]) |
- |
2000 |
|
2000 |
| 9.7.2, table 4(Construction [Glands (As per Cl.9.7.2 and Table-4 of IS: 14927 (Pt-1):2001)] ) |
- |
2000 |
|
2000 |
| 10.2(Cable supporting test for Surface mounting (As per Cl.10.2)) |
- |
2000 |
|
2000 |
| 10.3(Impact Test [ Cl.10.3 ]) |
- |
2000 |
|
2000 |
| 10.4(Linear Deflection Test [ Cl.10.4 ]) |
- |
2000 |
|
2000 |
| 11.1.1(Resistance to flame propagation (As per Cl. 11.1.1)) |
- |
1000 |
|
1000 |
| 12(Electrical Insulating Strength and Insulation Resistance Test. [ Cl.12.3 ]) |
- |
3000 |
|
3000 |
| 10.2(Cable supporting test for Surface mounting (As per Cl.10.2)) |
- |
2000 |
|
2000 |
|
- |
- - |
| 14141 |
MSME TESTING CENTRE (WR), MUMBAI
| 7119404
| IS 9537 : Part 3 (1983) |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
- |
14000 View breakup
Rs 14,000 For complete IS
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1(Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
1000 |
|
Rs.14,000/- for BIS Samples Rs.4950/- for upto and including 25mm, Rs.4,275/- for above 25mm |
| 6.1(Marking) |
- |
1000 |
|
Rs.14,000/- for BIS Samples Rs.4950/- for upto and including 25mm, Rs.4,275/- for above 25mm |
| 6.2(Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
1000 |
|
1000 |
| 7.1.1(Maximum and minimum outside diameter of socket) |
- |
1000 |
|
1000 |
| 7.1.1 Table-2(Length of Socket end) |
- |
1000 |
|
1000 |
| 7.1.2(Maximum and minimum outside diameter of conduit) |
- |
1000 |
|
1000 |
| 7.2(Minimum inside diameter of conduit) |
- |
1000 |
|
1000 |
| 7.3(Length of conduit) |
- |
1000 |
|
1000 |
| 7.4(Unifomity of The wall Thickness) |
- |
1000 |
|
1000 |
| 9.2(Bending Test i) At Room Temp ii) At Low Temp (-5 ±2°C)) |
- |
2000 |
|
2000 |
| 9.3(Compression Test as per caluse 9.3 of IS: 9537 (Part 1)-1980) |
- |
2000 |
|
2000 |
| 9.4(Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
2000 |
|
2000 |
| 9.5(Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
2000 |
|
2000 |
| 10(Resistance to Heat -Ball presure test) |
- |
2000 |
|
2000 |
| 11(Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
1000 |
|
1000 |
| 12(Electrical Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
3000 |
|
3000 |
| 12(Electrical Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
3000 |
|
3000 |
|
- |
- - |
| 14142 |
MSME TESTING CENTRE (WR), MUMBAI
| 7119404
| IS 3419 (1988) |
Specification for fittings for rigid non - Metallic (Second Revision) |
- |
10000 View breakup
Rs 10,000 For complete IS
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8 & 5(Visual Examination -IS:3419) |
- |
1000 |
|
1000 |
| 6.2 & 9.1- Table-1, ii(Inside Diameter of Collar for Slip type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-1, iii(Inside Diameter of Ridge for Slip type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-1, iv(Minimum overall length for Slip type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-1, v(Minimum wall thickness for Slip type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-2, ii(Inside Diameter of Collar for Socketed type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-2, iii(Inside Diameter of Ridge for Socketed type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-2, iv(Minimum overall length (a) for Socketed type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-2, v(Minimum overall length (l) for Socketed type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-2, vi(Minimum wall thickness for Socketed type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-3, ii(Inside Diameter of Collar(d6) for Clamp type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-3, iv(Inside Diameter of Ridge for Clamp type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-3, iv(Minimum length for Clamp type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-4, v(Length (l1) of Normal Type Bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-3, vi(Minimum wall thickness for Clamp type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-4, ii(Outside Dameter of Normal type bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-4, iii(Minimum Inside Diameter of Normal Type Bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-4, iv(Radious(R) of Normal Type Bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-5, ii(Outside Dameter of Slip type cupling bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-5, iii(Minimum Inside Diameter of Slip type cupling bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-5, iv(Inside Diameter of collar for Slip type cupling bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-5, v(R- for Slip type cupling bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-5, vi(Y- for Slip type cupling bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-5, vii(l2- for Slip type cupling bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-6, ii(Inside Diameter of collar for Normal type Elbows -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-6, iii(Length (l) of Normal Type Elbows -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-6, iv(Radious(r) of Normal Type Elbows -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-6, v(Minimum wall thicknes of Elbows -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-7, ii(Inside Diameter of Collear for Normal type Tees -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-7, iii(Length (l) of Normal type Tees -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-7, iv(Radious(r) of Normal type Tees -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-7, v( Minimum wall thicknes of Normal type Tees -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-8, ii(Inside Diameter of Collear for socketed type Tees - IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-8, iii(a - of socketed type Tees -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-8, iv(l - of socketed type Tees -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-8, v(Minimum wall thicknes of socketed type Tees -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-9, ii(B - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-9, iii(C - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-9, iv(D - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-9, v(E - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-9, vi(F(Max) - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-9, vii(F(Min) - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-9, viii(G - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-9, ix(t - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
| 10(Resistance to Heat -IS:3419) |
- |
2000 |
|
2000 |
| 11(Resistance to Burning - IS 3419) |
- |
2000 |
|
2000 |
| 12(Moisture Absorption - IS 3419) |
- |
2000 |
|
2000 |
| 13.2 &13.3(Resistance to chemival action in Acid solution - IS 3419) |
- |
2000 |
|
2000 |
| 13.2 &13.3(Resistance to chemival action in Alkaline solution - IS 3419) |
- |
2000 |
|
2000 |
| 14.1(Copper Test - IS 3419) |
- |
2000 |
|
2000 |
| 15, 15.3(Resistance to Oil - IS 3419) |
- |
2000 |
|
2000 |
| 15,15.4(Resistance to Oil - IS 3419) |
- |
2000 |
|
2000 |
| 16- Appendix-A(Resistance to Impact -IS 3419) |
- |
2000 |
|
2000 |
| 17.2(Electric Strength - IS 3419) |
- |
2000 |
|
2000 |
| 17.3(Insulation Resistance - IS 3419) |
- |
2000 |
|
2000 |
|
- |
- - |
| 14143 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 11722 (1986) |
Specification for thin walled flexible quick coupling pipes |
- |
4800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Pipe Manufacturing Process ) |
- |
|
|
|
| 5,5.1 (Workmsnship &Finish) |
- |
|
|
|
| 6 &7 ; Table 1 (Dimension & Tolerance) |
- |
|
|
|
| 8 (Length) |
- |
|
|
|
| 12 (Straightness) |
- |
|
|
|
| 13.1 (Flattening Test,IS 2328) |
- |
|
|
|
| 13.2 (Tensile Test ,; IS 1608(P1)) |
- |
|
|
|
|
- |
- " 2 nos.+coupler
Excluding excl hydraulic test,chemical tests |
| 14144 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 4224 (1972) |
Specification for steel wire for staples, pins and clips (First Revision) |
- |
525 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 (Freedom from defects , IS 4224) |
- |
|
|
|
| 5 (Sizes and Tolerances - IS 4224) |
- |
|
|
|
| 6 (Finish) |
- |
|
|
|
| 7.1 (Tensile Test - IS 1608(Pt -1)) |
- |
|
|
|
|
- |
- " 5 m + 100g drill.
Excluding chemical test |
| 14145 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 903 (1993) |
Specification for Fire Hose Delivery Couplings, Branch Pipe, Nozzles And Nozzle Spanner - Specificaion |
- |
Rs 3600/ View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3 (Finish and workmanship) |
- |
|
|
|
| 4 (Marking) |
- |
|
|
|
| 5 (Delivery hose coupling) |
- |
|
|
|
| 5.3 (Size and Dimension ) |
- |
|
|
|
| 7.3 (Hydraulic test requirement) |
- |
|
|
|
| 6 (Branch pipe) |
- |
|
|
|
| 6.3 (Hydraulic test requirement) |
- |
|
|
|
| 7 (Nozzle) |
- |
|
|
|
| 7.3 (Hydraulic test requirement) |
- |
|
|
|
| 8.2 (Shape & Dimensions of Spanner) |
- |
|
|
|
| 8.4 (Deflection test of Spanner) |
- |
|
|
|
|
- |
- " 1 pcs
Excluding Except Hydraulic Test Requirement, Deflection Test Requirement,chemical tests |
| 14146 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 13997 (2014) |
Drums, large open top - Specification (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5, Table 1 (Dimensions-D2) |
- |
|
|
|
| 5, Table 1 (Dimensions-D3) |
- |
|
|
|
| 5, Table 1 (Dimensions-D4) |
- |
|
|
|
| 5, Table 1 (Dimensions-H1) |
- |
|
|
|
| 5, Table 1 (Dimensions-H5) |
- |
|
|
|
| 5, Table 1 (Dimensions-h2) |
- |
|
|
|
| 5, Table 1 (Dimensions-h3) |
- |
|
|
|
| 5, Table 1 (Dimensions-h4) |
- |
|
|
|
| 5, Table 1 (Dimensions-p1) |
- |
|
|
|
| 6.2 (The nominal thickness of steel sheets for body
and ends ) |
- |
|
|
|
| 7.1 ( CONSTRUCTION) |
- |
|
|
|
| 7.2 ( CONSTRUCTION) |
- |
|
|
|
| 7.3 ( CONSTRUCTION- Double Seam/Spiral Seam/Triple Seam Construction for Grade A Drums) |
- |
|
|
|
| 7.4 ( CONSTRUCTION-Spiral Seam/Triple Seam Construction for Grade B Drums) |
- |
|
|
|
| 7.5 ( CONSTRUCTION) |
- |
|
|
|
| 7.6 ( CONSTRUCTION) |
- |
|
|
|
| 7.7 ( CONSTRUCTION) |
- |
|
|
|
| 7.8 ( CONSTRUCTION) |
- |
|
|
|
| 7.9 (Closures) |
- |
|
|
|
| 7.10(a) (Closures) |
- |
|
|
|
| 7.10(b) (Closures) |
- |
|
|
|
| 7.10(c) (Closures) |
- |
|
|
|
| 7.10(d) (Closures) |
- |
|
|
|
| 7.11 ( Locking Ring) |
- |
|
|
|
| 8.1 (FINISH
) |
- |
|
|
|
| 8.2 (FINISH
) |
- |
|
|
|
| 9 (leakage test) |
- |
|
|
|
|
- |
- - |
| 14147 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 2653 (2004) |
Safety matches in boxes - Specification (Third Revision) |
- |
Rs 2570.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.2.1 (Matchboxes) |
- |
|
|
|
| 5.1.2.2 (Matchboxes) |
- |
|
|
|
| 5.1.3 (Envelopment) |
- |
|
|
|
| 5.1.4 (Ease of Opening) |
- |
|
|
|
| 5.1.5 (Retention of Contents) |
- |
|
|
|
| 5.1.6.1 (Defective Match Boxes) |
- |
|
|
|
| 5.1.6.2 (Defective Match Boxes) |
- |
|
|
|
| 5.2.1.1 (Match Splints) |
- |
|
|
|
| 5.2.1.2 (Match Splints) |
- |
|
|
|
| 5.2.1.2 (Minimum thickness) |
- |
|
|
|
| 5.2.1.2 (Average thickness) |
- |
|
|
|
| 5.2.2 (Unserviceable Sticks) |
- |
|
|
|
| 5.3 (Match Boxes) |
- |
|
|
|
| 6.1.1 (Striking Performance - General) |
- |
|
|
|
| 6.1.2 (Safety Matches) |
- |
|
|
|
| 6.2 (Ignition Below 170 ˚C) |
- |
|
|
|
| 6.3 (Ignition Under Impact) |
- |
|
|
|
| 6.4.1 (Durability of the Striking Surface) |
- |
|
|
|
| 6.4.2 (Ignition of the Striking Surface) |
- |
|
|
|
| 6.4.3 (Loss of Burning Fragments) |
- |
|
|
|
| 6.5 (Damp Proofness for Match Boxes) |
- |
|
|
|
|
- |
- " 2 dozen |
| 14148 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 4984 (2016) |
Polyethylene pipes for water supply - Specification (Fifth Revision) |
- |
42325 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.10(Slow Crack Growth Rate) |
- |
5500 |
|
NIl |
| 8.9 table-6(Elongation at Break) |
- |
1100 |
|
Nil |
| 8.8(Tensile Strength for Butt-fusion) |
- |
1100 |
|
Nil |
| 8.7(Density) |
- |
500 |
|
Nil |
| 8.5 (Oxidation Induction Time) |
- |
2200 |
|
Nil |
| 8.4( Melt Flow Rate) |
- |
1100 |
|
Nil |
| 8.2(Longitudinal Reversion Test) |
- |
1100 |
|
Nil |
| 8.1.2 table -5(Internal Pressure Creep Rupture Test of Pipe Joints) |
- |
1600 |
|
Nil |
| 8,/8.1/8.1.1 table-5(PERFORMANCE REQUIREMENTS / Hydraulic Characteristics/ Internal Pressure Creep Rupture Test of Pipe) |
- |
22000 |
|
Nil |
| 7.4.1.2(Ovality) |
- |
250 |
|
Nil |
| Cl-7.4(Mean Outside Diameter (For upto 50 mm take 8 reading, above 50mm take 6 reading & average will be reported)) |
- |
250 |
|
Nil |
| 7.2(Length) |
- |
250 |
|
Nil |
| 6.2.1(6.1.1 Identification Stripes) |
- |
250 |
|
Nil |
| 6.2(Colour) |
- |
250 |
|
Nil |
| 6.1.4(PIPE DESCRIPTION) |
- |
250 |
|
Nil |
| 6.1.3 (PIPE DESCRIPTION) |
- |
0 |
|
Nil |
| 6, 6.1.2(PIPE DESCRIPTION) |
- |
0 |
|
Nil |
| 6, 6.1.1(PIPE DESCRIPTION) |
- |
0 |
|
Nil |
| 6, 6.1(PIPE DESCRIPTION) |
- |
0 |
|
Nil |
| 8.6(Overall migration) |
- |
2200 |
|
Nil |
| 8.3(Carbon black) |
- |
925 |
|
Nil |
| 5.3 (a)(Carbon Black Master Batch) |
- |
925 |
|
Nil |
| 5.2(Polyethylene Resin) |
- |
2000 |
|
Nil |
|
31 Dec, 2026 |
- - |
| 14149 |
URS PRODUCTS AND TESTING PVT LTD (F3), NOIDA
| 8136826
| IS 16270 (2014) |
Secondary cells and batteries for solar photovoltaic application - General requirements and methods of test |
- |
331000 View breakup
Rs.3,31,000/-
[10% Discount to BIS]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.4(Marking) |
- |
9999.99 |
|
10% discount to BIS |
| 4(Condition of use) |
- |
40000 |
|
10% discount to BIS |
| 5.1(Mechanical Endurance) |
- |
20000 |
|
10% discount to BIS |
| 5.2(Charge efficiency) |
- |
30000 |
|
10% discount to BIS |
| 5.3(Deep discharge protection) |
- |
10000 |
|
10% discount to BIS |
| 5.5(Dafety) |
- |
10000 |
|
10% discount to BIS |
| 5.6(Documentation) |
- |
10000 |
|
10% discount to BIS |
| 6(Finctional Characteristics) |
- |
4999.98 |
|
10% discount to BIS |
| 7(General test conditions) |
- |
5000 |
|
10% discount to BIS |
| 8.1(Capacity test) |
- |
15000 |
|
10% discount to BIS |
| 8.2(Endurance test) |
- |
20000 |
|
10% discount to BIS |
| 8.3(Charge retention test) |
- |
15000 |
|
10% discount to BIS |
| 8.4(Cycle endurance in Photovoltaic application) |
- |
20000 |
|
10% discount to BIS |
| 8.5(Sulphation Test) |
- |
40000 |
|
10% discount to BIS |
| 8.6(Water loss test) |
- |
40000 |
|
10% discount to BIS |
| 8.7(Non spillability) |
- |
30000 |
|
10% discount to BIS |
|
31 Dec, 2026 |
- Included w.e.f. 24-07-2020.Except Flooded Lead Acid Batteries. |
| 14150 |
URS PRODUCTS AND TESTING PVT LTD (F3), NOIDA
| 8136826
| IS 16221 : Part 2 (2015) |
Safety of power converters for use in photovoltaic power systems: Part 2 particular requirements for inverters |
- |
190500 View breakup
Rs.1,90,500/-
[10% Discount to BIS]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 14(Components) |
- |
10000 |
|
Test is in Inclusion |
| 4(General Test Requireements) |
- |
40000 |
|
10% Discount to BIS |
| 5(Marking and documentation) |
- |
5000 |
|
10% Discount to BIS |
| 6(Environmental requirements and conditions) |
- |
50000 |
|
10% Discount to BIS |
| 7(Protection against electric shock and energy hazards) |
- |
30000 |
|
10% Discount to BIS |
| 9(Protection against Fire Hazards) |
- |
10000 |
|
10% Discount to BIS |
| 11(Protection against Liquid Hazards) |
- |
10000 |
|
10% Discount to BIS |
| 13(Physical Requirements) |
- |
10000 |
|
10% Discount to BIS |
| 8(Protection against Mechanical Hazards) |
- |
10000 |
|
10% Discount to BIS |
| 10(Protection against Sonic Pressure Hazards) |
- |
10000 |
|
10% Discount to BIS |
| 12(Protection against Chemical Hazards) |
- |
10000 |
|
10% Discount to BIS |
|
31 Dec, 2026 |
- Excluding:
Cl.10.2-Protection against sonic Pressure hazards, Cl.13.6.4-UV resistance, Cl.14 –Component. Included w.e.f. 24-07-2020. |
| 14151 |
URS PRODUCTS AND TESTING PVT LTD (F3), NOIDA
| 8136826
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
75000 View breakup
Rs.75,000/- [15% Discount to BIS]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5(Components) |
- |
500 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 4.6(Power interface) |
- |
10000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 4.7(Marking & instructions) |
- |
1000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 5.1(Protection against shock and energy hazards) |
- |
7000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 5.2(Requirement of auxiliary circuits) |
- |
1000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 5.3(Protective earthing and bonding) |
- |
8000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 5.4(AC and DC power isolation) |
- |
7500 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 5.5(Over current and earth fault condition) |
- |
3000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 5.6(Safety interlocks) |
- |
1000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
4000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 6.1(Wiring, connections and supply) |
- |
2000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 6.2(Connection to power) |
- |
1500 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 6.3(Wiring terminals for external power conductors) |
- |
2000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 7.1(Enclosure) |
- |
2000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 7.2(STABILITY) |
- |
2000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 7.3(MECHANICAL STRENGTH) |
- |
4000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 7.4(Construction details) |
- |
500 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 7.5(Resistance to fire) |
- |
2000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 7.6(Battery location) |
- |
1000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 7.7(Temperature rise) |
- |
3000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 8.1(General procision for earth leakage) |
- |
3000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 8.2(Electric Strength) |
- |
4000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 8.3(Abnormal operating and fault conditions) |
- |
3000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 9.0(Connection to telecommunication networks) |
- |
2000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
|
31 Dec, 2026 |
- Excluding: Capacitor Bridging Insulation (Cl.4.5 / RD 1.5.6), Resistor Bridging Insulation (Cl.4.5 / RD 1.5.7), Surge Suppressor (Cl.4.5 / RD 1.5.7), Ventilation of Battery Compartment (Cl. Annex-M). Non-linear loads (Cl.3.3.3, Annex-L.5).
Additional Products/
Test Facility included
w.e.f. 18.07.2018.
For rating up to 300V,
1Φ, AC |
| 14152 |
URS PRODUCTS AND TESTING PVT LTD (F3), NOIDA
| 8136826
| IS 16046 : Part 2 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 2 Lithium Systems ( Second Revision ) |
- |
60000 View breakup
Rs.60000/- [15% discount to BIS]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
100 |
|
- |
| 5(General Safety Considerations) |
- |
100 |
|
- |
| 5.1(General) |
- |
500 |
|
- |
| 5.2(Insulation and Wiring) |
- |
1000 |
|
- |
| 5.3(Venting) |
- |
499.99 |
|
- |
| 5.4(Temperature, Voltage and Current Management) |
- |
500 |
|
- |
| 5.5(Terminal Contacts) |
- |
500 |
|
- |
| 5.6(Assembly of Cells into batteries) |
- |
500 |
|
- |
| 5.7(Quality Plan) |
- |
100 |
|
- |
| 5.8(Battery Safety Components) |
- |
100 |
|
- |
| 6(Type Test and Sample Size) |
- |
500 |
|
- |
| 7(Specific requirements and tests) |
- |
8000 |
|
- |
| 7.1(Charging procedure for test purposes) |
- |
10000 |
|
- |
| 7.2(Intended Use) |
- |
11000 |
|
- |
| 7.3(Reasonably foreseeable misuse) |
- |
20000 |
|
- |
| 8(Information for safety) |
- |
1000 |
|
- |
| 8.1(General) |
- |
1000 |
|
- |
| 8.2(Small Cell and battery safety information) |
- |
500 |
|
- |
| 9(Marking) |
- |
1000 |
|
- |
| 9.1(Cell Marking) |
- |
500 |
|
- |
| 9.2(Battery Marking) |
- |
500 |
|
- |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
500 |
|
- |
| 9.4(Other information) |
- |
1000 |
|
- |
| 10(Packaging) |
- |
600 |
|
- |
|
31 Dec, 2026 |
- Revised version included
w.e.f. 28.01.2019.
Exclusion : Clause 7.3.1 of IS 16047: Part 3 |
| 14153 |
URS PRODUCTS AND TESTING PVT LTD (F3), NOIDA
| 8136826
| IS 16046 : Part 1 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 1 Nickel Systems ( Second Revision ) |
- |
60000 View breakup
Rs.60000/- [15% discount to BIS]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
500 |
|
15 %
Discount to
BIS |
| 5(General Safety Considerations) |
- |
500 |
|
15 %
Discount to
BIS |
| 5.1(General) |
- |
100 |
|
- |
| 5.2(Insulation and Wiring) |
- |
1000 |
|
- |
| 5.3(Venting) |
- |
100 |
|
- |
| 5.4(Temperature, Voltage and Current Management) |
- |
500 |
|
- |
| 5.5(Terminal Contacts) |
- |
500 |
|
- |
| 5.6(Assembly of Cells into batteries) |
- |
500 |
|
- |
| 5.7(Quality Plan) |
- |
100 |
|
- |
| 6(Tyoe Test amd Sample Size) |
- |
600 |
|
- |
| 7(Specific requirements and tests) |
- |
5000 |
|
- |
| 7.1(Charging procedure for test purposes) |
- |
8000 |
|
- |
| 7.2(Intended Use) |
- |
14000 |
|
- |
| 7.3(Reasonably foreseeable misuse) |
- |
20000 |
|
- |
| 8(Information for safety) |
- |
1000 |
|
- |
| 8.1(General) |
- |
1000 |
|
- |
| 8.2(Small Cell and battery safety information) |
- |
500 |
|
- |
| 9(Marking) |
- |
1000 |
|
- |
| 9.1(Cell Marking) |
- |
500 |
|
- |
| 9.2(Battery Marking) |
- |
500 |
|
- |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
500 |
|
- |
| 9.4(Other information) |
- |
1000 |
|
- |
| 10(Packaging) |
- |
600 |
|
- |
|
31 Dec, 2026 |
- Revised version included
w.e.f. 28.01.2019. |
| 14154 |
URS PRODUCTS AND TESTING PVT LTD (F3), NOIDA
| 8136826
| IS 8978 (1992) |
Specification for electric instantaneous water heaters (Second Revision) |
- |
18000 View breakup
Rs.18000/-
[15% discount to BIS]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.10 of IS 8978 : 1992(Finish) |
- |
1000 |
|
15% discount to BIS |
| Cl.11 of IS 8978 : 1992(Operation of flow switch) |
- |
10000 |
|
15% discount to BIS |
| Cl.12 of IS 8978 : 1992(Endurance) |
- |
7000 |
|
15% discount to BIS |
| Cl.7.1 of IS 302-1:2008(Marking : Rated Voltage) |
- |
30 |
|
15% discount to BIS |
| Cl.7.1 of IS 302-1:2008(Marking : Nature of supply) |
- |
30 |
|
15% discount to BIS |
| Cl.7.1 of IS 302-1:2008(Marking : Rated power input) |
- |
30 |
|
15% discount to BIS |
| Cl.7.1 of IS 302-1:2008(Marking : Manufacture identification) |
- |
30 |
|
15% discount to BIS |
| Cl.7.1 of IS 302-1:2008(Marking : Molel or type) |
- |
30 |
|
15% discount to BIS |
| Cl.7.1 of IS 302-1:2008(Marking : Symbol for class II) |
- |
30 |
|
15% discount to BIS |
| Cl.7.1 of IS 302-1:2008(Marking : IP number ) |
- |
30 |
|
15% discount to BIS |
| Cl.7.1 of IS 302-1:2008(Marking : Country of manufacture) |
- |
30 |
|
15% discount to BIS |
| Cl.7.1 of IS 302-2-35:2017(Marking : rated pressure) |
- |
30 |
|
15% discount to BIS |
| Cl.7.6 of IS 302-1:2008(Marking : Symbols) |
- |
30 |
|
15% discount to BIS |
| Cl.7.8 of IS 302-1:2008(Marking : Terminal for connection ) |
- |
30 |
|
15% discount to BIS |
| Cl.7.10 & 7.11 of IS 302-1:2008(Marking : Indication for direction of control) |
- |
30 |
|
15% discount to BIS |
| Cl.7.13 of IS 302-1:2008(Marking : Language) |
- |
30 |
|
15% discount to BIS |
| Cl.7.14 of IS 302-1:2008(Marking ; Legibility and durability) |
- |
30 |
|
15% discount to BIS |
| Cl.7.15 of IS 302-1:2008(Marking : Position of marking) |
- |
30 |
|
15% discount to BIS |
| Cl.7.101 of IS 302-2-35:2017(Marking : Woter inlet and outlet idetification) |
- |
30 |
|
15% discount to BIS |
| Cl.7.102 of IS 302-2-35:2017(Marking : Standard mark) |
- |
30 |
|
15% discount to BIS |
| Cl.8 of IS 302-2-35:2017(Protection Against Access To Live Parts) |
- |
2000 |
|
15% discount to BIS |
| Cl.10 of IS 302-2- 35:2017(Power Input & Current ) |
- |
2000 |
|
15% discount to BIS |
| Cl.11 of 302-2-35:2017(Heating : Temperature rise of test corner) |
- |
667 |
|
15% discount to BIS |
| Cl.11 of 302-2-35:2017(Heating : Insulation of supply cord) |
- |
667 |
|
15% discount to BIS |
| Cl.11 of 302-2-35:2017(Heating : room temperature) |
- |
667 |
|
15% discount to BIS |
| Cl.13 of IS 302-2-35:2017(Leakage Current & 3 Strength at Operating Temperature ) |
- |
1000 |
|
15% discount to BIS |
| Cl.13 of IS 302-2-35:2017(Leakage Current & 3 Strength at Operating Temperature : High voltage ) |
- |
1000 |
|
15% discount to BIS |
| Cl.14 of IS 302-2-35:2017(Transient Over Voltages ) |
- |
4000 |
|
15% discount to BIS |
| Cl.15 of IS 302-2-35:2017(Moisture Resistance ) |
- |
8000 |
|
15% discount to BIS |
| Cl.16 of IS 302-2-35:2017(Leakage Current and Electric Strength (After Humidity)) |
- |
2000 |
|
15% discount to BIS |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation : Emission of flames, molten metal ,or poisonous or ignitable gas) |
- |
400 |
|
15% discount to BIS |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation : Temperature rise of test corner) |
- |
400 |
|
15% discount to BIS |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation : Temperature rise of insulation of supply cord) |
- |
400 |
|
15% discount to BIS |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation : High voltage) |
- |
400 |
|
15% discount to BIS |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation : effect on container) |
- |
400 |
|
15% discount to BIS |
| Cl.20 of IS 302-2-35:2017(Stability & Mechanical Hazards
) |
- |
2000 |
|
15% discount to BIS |
| Cl.21.1 of IS 302-1:2008(Mechanical strength : Rough handling in normal use) |
- |
1000 |
|
15% discount to BIS |
| Cl. 21.2 of IS 302-1:2008(Mechanical strength : prevent penetration by sharp implements. ) |
- |
1000 |
|
15% discount to BIS |
| Cl.22.1 of IS 302-1:2008(Construction : IP test
) |
- |
84 |
|
15% discount to BIS |
| Cl.22.2 of IS 302-1:2008(Construction : connection to supply mains
) |
- |
84 |
|
15% discount to BIS |
| Cl.22.6 of IS 302-1:2008(Construction : effect of water on 3 insulation
) |
- |
84 |
|
15% discount to BIS |
| Cl.22.6 of IS 302-2-35:2017(Construction : size of drain hole
) |
- |
84 |
|
15% discount to BIS |
| Cl.22.7 of IS 302-1:2008(Construction : safeguards against the risk of excessive pressure.
) |
- |
84 |
|
15% discount to BIS |
| Cl.22.11 of IS 302-1:2008(Construction : Fixing of non detachable parts
) |
- |
84 |
|
15% discount to BIS |
| Cl.22.12 of IS 302-1:2008(Construction : Fixing of Handle, knob, grips, levers and similar parts
) |
- |
84 |
|
15% discount to BIS |
| Cl.22.14 of IS 302-1:2008(Construction : Ragged or sharp edges
) |
- |
8415 |
|
- |
| Cl.22.17 of IS 302-1:2008(Construction : Spacers
) |
- |
84 |
|
15% discount to BIS |
| Cl.22.18 of IS 302-1:2008(Construction : Resistance to corrosion
) |
- |
84 |
|
15% discount to BIS |
| Cl 22.26 ,Cl.22.28, Cl 22.29, Cl 22.30 , Cl 22.31, Cl 22.32 of
IS 302-1:2008(Construction : Supplymentry/ double / reinforced insulation for Class II/ Class III appliance ) |
- |
84 |
|
15% discount to BIS |
| Cl.22.33 of
IS 302-1:2008(Construction : Direct contact of liquids ) |
- |
84 |
|
15% discount to BIS |
| Cl.22.34, Cl 22.35 of
IS 302-1:2008(Construction : Shaft of operating Knobs ) |
- |
84 |
|
15% discount to BIS |
| Cl.22.44 of IS 302-1:2008(Construction : Shape and decoration
) |
- |
84 |
|
15% discount to BIS |
| Cl.22.47 of IS 302-2-35:2017(Construction : Water pressure test
) |
- |
84 |
|
15% discount to BIS |
| Cl.22.101 of IS 302-2-35:2017(Construction : Rated pressure of closed water heater
) |
- |
84 |
|
15% discount to BIS |
| Cl.22.102 of IS 302-2-35:2017(Construction : excessive temperature of outlet
) |
- |
84 |
|
15% discount to BIS |
| Cl.22.103 of IS 302-2-35:2017(Construction : Pressure relief device operation for closed water heater
) |
- |
84 |
|
15% discount to BIS |
| Cl.22.104 of IS 302-2-35:2017(Construction : Pressure in open outlet water heaters
) |
- |
84 |
|
15% discount to BIS |
| Cl.22.106 of IS 302-2-35:2017(Construction : Operation of thermal cut out for closed water heater
) |
- |
84 |
|
15% discount to BIS |
| Cl.22.107 of IS 302-2-35:2017(Construction : Temperature of outlet
) |
- |
84 |
|
15% discount to BIS |
| Cl.22.108 of IS 302-2-35:2017(Construction : Temperature of outlet water intended to supply for showring
) |
- |
84 |
|
15% discount to BIS |
| Cl.22.109 of IS 302-2-35:2017(Construction : Operation of presure switch of open outlet water heater
) |
- |
84 |
|
15% discount to BIS |
| Cl.22.110 of IS 302-2-35:2017(Construction : Provision for fixing to wall
) |
- |
84 |
|
15% discount to BIS |
| Cl.23 of IS 302-2-35:2017(Internal Wiring) |
- |
1000 |
|
15% discount to BIS |
| Cl.23 of IS 302-2-35:2017(Internal Wiring ; Colour of earthing conductor) |
- |
1000 |
|
15% discount to BIS |
| Cl.24 of IS 302-2-35:2017(Component
) |
- |
2000 |
|
15% discount to BIS |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
223 |
|
15% discount to BIS |
| Cl.25.1 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : connection to the supply mains) |
- |
223 |
|
15% discount to BIS |
| Cl.25.5 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : Type of attachment ) |
- |
223 |
|
15% discount to BIS |
| Cl.25.8 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : Resistance of supply cord ) |
- |
223 |
|
15% discount to BIS |
| Cl.25.10 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : Colour of Earthing conductor ) |
- |
223 |
|
15% discount to BIS |
| Cl.25.12 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : Moulding of supply cord ) |
- |
223 |
|
15% discount to BIS |
| Cl.25.15 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : Cord grip test ) |
- |
223 |
|
15% discount to BIS |
| Cl.25.15 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : Cord grip test - displacement ) |
- |
223 |
|
15% discount to BIS |
| Cl.25.18 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
223 |
|
15% discount to BI |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
2000 |
|
15% discount to BI |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
500 |
|
15% discount to BIS |
| Cl.27.5 of IS 302-2-35:2017(Provision for Earthing : ECR ) |
- |
500 |
|
15% discount to BIS |
| Cl.28 of IS 302-2-35:2017(Screws and Connections
) |
- |
1000 |
|
15% discount to BIS |
| Cl.29.1 of IS 302-2-35:2017(Clearances, Creepage Distances and Solid Insulation : Clearance distance ) |
- |
1250 |
|
15% discount to BIS |
| Cl.29.2 of IS 302-2-35:2017(Clearances, Creepage Distances and Solid Insulation : Creepage distance ) |
- |
1250 |
|
15% discount to BIS |
| Cl.30.1 of IS 302-1:2008(Resistance to Heat and Fire) |
- |
1500 |
|
15% discount to BIS |
| Cl.30.2 of IS 302-1:2008(Resistance to Heat and Fire) |
- |
1500 |
|
15% discount to BIS |
| Cl.31 of IS 302-2-35: 2017(Resistance to Rusting
) |
- |
1000 |
|
15% discount to BIS |
|
31 Dec, 2026 |
- - |
| 14155 |
URS PRODUCTS AND TESTING PVT LTD (F3), NOIDA
| 8136826
| IS 4250 (1980) |
Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
100 |
|
15% discount to BIS |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
15% discount to BIS |
| 7.2(Marking) |
- |
100 |
|
15% discount to BIS |
| 7.4(Marking) |
- |
100 |
|
15% discount to BIS |
| 7.5(Marking) |
- |
100 |
|
15% discount to BIS |
| 7.6(Marking) |
- |
100 |
|
15% discount to BIS |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
1000 |
|
15% discount to BIS |
| 9(Starting, IS 302-1) |
- |
200 |
|
15% discount to BIS |
| 10(Power Input and Current, IS 302-1) |
- |
1000 |
|
15% discount to BIS |
| 11(Heating, IS 302-1) |
- |
1000 |
|
15% discount to BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
750 |
|
15% discount to BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
750 |
|
15% discount to BIS |
| 14(Transient Over Voltages, IS 302-1) |
- |
100 |
|
15% discount to BIS |
| 15.1(Moisture Resistance, IS 302-1) |
- |
250 |
|
15% discount to BIS |
| 15.2(Moisture Resistance-Spillage test) |
- |
250 |
|
15% discount to BIS |
| 15(Moisture Resistance, IS 302-1) |
- |
500 |
|
15% discount to BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
15% discount to BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
500 |
|
15% discount to BIS |
| 19(Abnormal Operation, IS 302-1) |
- |
750 |
|
15% discount to BIS |
| 20(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
15% discount to BIS |
| 21(Mechanical Strength, IS 302-1) |
- |
750 |
|
15% discount to BIS |
| 22.1(Construction, IS 302-1) |
- |
100 |
|
15% discount to BIS |
| 22.2(Construction) |
- |
100 |
|
15% discount to BIS |
| 22.3(Construction) |
- |
100 |
|
15% discount to BIS |
| 22.4(Construction) |
- |
100 |
|
15% discount to BIS |
| 22.5(Construction) |
- |
100 |
|
15% discount to BIS |
| 22.6(Construction) |
- |
100 |
|
15% discount to BIS |
| 22.8(Construction) |
- |
100 |
|
15% discount to BIS |
| 22.9(Construction) |
- |
100 |
|
15% discount to BIS |
| 22.1(Construction) |
- |
500 |
|
15% discount to BIS |
| 23(Internal Wiring, IS 302-1) |
- |
500 |
|
15% discount to BIS |
| 24.1(Components, IS 302-1) |
- |
100 |
|
15% discount to BIS |
| 24.2(Components) |
- |
100 |
|
15% discount to BIS |
| 24.4(Components) |
- |
100 |
|
15% discount to BIS |
| 24.5(Components) |
- |
100 |
|
15% discount to BIS |
| 24.6(Components) |
- |
100 |
|
15% discount to BIS |
| 24.7(Components) |
- |
100 |
|
15% discount to BIS |
| 24.8(Components) |
- |
100 |
|
15% discount to BIS |
| 24.9(Components) |
- |
100 |
|
15% discount to BIS |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
30 |
|
15% discount to BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
500 |
|
15% discount to BIS |
| 27(Provision for Earthing, IS 302-1) |
- |
750 |
|
15% discount to BIS |
| 28(Screws & Connections, IS 302-1) |
- |
500 |
|
15% discount to BIS |
| 29(Clearances and Distances through Insulation, IS 302-1) |
- |
1000 |
|
15% discount to BIS |
| 30(Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
1000 |
|
15% discount to BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
1000 |
|
15% discount to BIS |
| 34.2(Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
150 |
|
15% discount to BIS |
| 34.3(Whisking egg whites ) |
- |
200 |
|
15% discount to BIS |
| 34.4(IDLI batter-Grinding of black gram) |
- |
200 |
|
15% discount to BIS |
| 34.4(IDLI batter-Grinding of rice) |
- |
200 |
|
15% discount to BIS |
| 34.5.1 (a)(Operational test for juicers ) |
- |
100 |
|
15% discount to BIS |
| 34.5.1 (b)(Operational test for juicers ) |
- |
250 |
|
15% discount to BIS |
| 34.5.2(Operational test for juicers ) |
- |
250 |
|
15% discount to BIS |
| 35(Temperature withstand test for bowl) |
- |
250 |
|
15% discount to BIS |
| 36(Test for controls ) |
- |
750 |
|
15% discount to BIS |
| 37(Strength of Assembly ) |
- |
750 |
|
15% discount to BIS |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
30 |
|
15% discount to BIS |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
30 |
|
15% discount to BIS |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
30 |
|
15% discount to BIS |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
30 |
|
15% discount to BIS |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
30 |
|
15% discount to BIS |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
30 |
|
15% discount to BIS |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
30 |
|
15% discount to BIS |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
30 |
|
15% discount to BIS |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
30 |
|
15% discount to BIS |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
30 |
|
15% discount to BIS |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
30 |
|
15% discount to BIS |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
30 |
|
15% discount to BIS |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
30 |
|
15% discount to BIS |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
30 |
|
15% discount to BIS |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
30 |
|
15% discount to BIS |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
30 |
|
15% discount to BIS |
|
31 Dec, 2026 |
- - |
| 14156 |
URS PRODUCTS AND TESTING PVT LTD (F3), NOIDA
| 8136826
| IS 4159 (2002) |
Mineral filled sheathed heating elements - Specification (Third Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 of IS 4159:2002 &
IS 302-1:2008
(Classification) |
- |
100 |
|
15% discount to BIS |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
500 |
|
15% discount to BIS |
| Cl.8 of IS 4159:2002 & IS 302‐1:2008(Protection Against Electric Shock) |
- |
900 |
|
15% discount to BIS |
| Cl.10 of IS 4159:2002 &
IS 302-1:2008(Input & Current) |
- |
1000 |
|
15% discount to BIS |
| Cl.11 of IS 4159:2002 & IS 302‐1:2008(Temperature Rise) |
- |
1000 |
|
15% discount to BIS |
| Cl.13 of IS 4159:2002 & IS 302-1: 2008(Electrical Insulation and Leakage Current at Operating Temperature) |
- |
750 |
|
15% discount to BIS |
| Cl.13 of IS 4159:2002 & IS 302-1: 2008(Electrical Insulation and Leakage Current at Operating Temperature) |
- |
750 |
|
15% discount to BIS |
| Cl.15 of IS 4159:2002 & IS 302-1: 2008(Moisture Resistance) |
- |
1000 |
|
15% discount to BIS |
| Cl.16 of IS 4159:2002 & IS 302-1: 2008(Insulation Resistance & Electric Strength (after Humidity Treatment)) |
- |
750 |
|
15% discount to BIS |
| Cl.16 of IS 4159:2002 & IS 302-1: 2008(Insulation Resistance & Electric Strength (after Humidity Treatment)) |
- |
750 |
|
15% discount to BIS |
| Cl.18 of IS 4159:2002(Endurance Test
) |
- |
2000 |
|
15% discount to BIS |
| Cl.19 of IS 4159:2002 & IS 302-1: 2008(Abnormal Operation) |
- |
1000 |
|
15% discount to BIS |
| Cl.20 of IS 4159:2002 & IS 302-1: 2008(Stability & Mechanical Hazards
) |
- |
500 |
|
15% discount to BIS |
| Cl.21 of IS 4159:2002 & IS 302-1: 2008(Mechanical Strength) |
- |
500 |
|
15% discount to BIS |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
300 |
|
15% discount to BIS |
| Cl.23 of IS 4159:2002 &
IS 302-1: 2008(Internal Wiring
) |
- |
200 |
|
15% discount to BIS |
| Cl.24 of IS 4159:2002 &
IS 302-1: 2008(Component ) |
- |
200 |
|
15% discount to BIS |
| Cl.25 of IS 4159:2002 & IS 302-1: 2008(Supply connection & external flexible cables & cords) |
- |
300 |
|
15% discount to BIS |
| Cl.26 of IS 4159:2002 & IS 302-1: 2008(Terminals for External Conductors) |
- |
200 |
|
15% discount to BIS |
| Cl.27 of IS 4159:2002 & IS 302-1: 2008(Provision for Earthing) |
- |
1000 |
|
15% discount to BIS |
| Cl.28 of IS 4159:2002 & IS 302-1: 2008(Screws & Connection ) |
- |
300 |
|
15% discount to BIS |
| Cl. 29 of IS 4159:2002 &
IS 302-1: 2008(Creepage Distances & Clearances) |
- |
1000 |
|
15% discount to BIS |
| Cl. 30 of IS 4159:2002 &
IS 302-1: 2008(Resistance to Heat, Fire and Tracking) |
- |
500 |
|
15% discount to BIS |
| Cl. 30 of IS 4159:2002 &
IS 302-1: 2008(Resistance to Heat, Fire and Tracking) |
- |
250 |
|
15% discount to BIS |
| Cl. 31 of IS 4159:2002 &
IS 302-1: 2008(Resistance to Rusting) |
- |
750 |
|
15% discount to BIS |
| Cl. 33.1 of IS 4159:2002(Finish Test
) |
- |
750 |
|
15% discount to BIS |
| Cl. 102 of IS 4159:2002(Leakage & Hydrostatic Strength Test
(for Oil heating elements)
) |
- |
750 |
|
15% discount to BIS |
|
31 Dec, 2026 |
- - |
| 14157 |
URS PRODUCTS AND TESTING PVT LTD (F3), NOIDA
| 8136826
| IS 2082 (2018) |
Stationary storage type electric water heaters - Specification (Fifth Revision) |
- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| (Cl.15 of IS 2082:2018)(Verification of the Rated Capacity) |
- |
2500 |
|
15 % Discount to BIS |
| (Cl.16 of IS 2082:2018)(Standing Loss per 24 Hours) |
- |
2500 |
|
15 % Discount to BIS |
| (Cl.17 of IS 2082:2018)(Hot Water Output) |
- |
2500 |
|
15 % Discount to BIS |
| (Cl.18 of IS 2082:2018)( Reheating Time) |
- |
2500 |
|
15 % Discount to BIS |
| (Cl.19 of IS 2082:2018)(Mixing Factor) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.20 of IS 2082:2018)(Deviation of Dial Calibration) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.21 of IS 2082:2018)(Cyclic Temperature Variation) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.22 of IS 2082:2018)(Finish) |
- |
500 |
|
15 % Discount to BIS |
| 7(Marking) |
- |
500 |
|
15 % Discount to BIS |
| 6(Classification ) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.8 of IS 302-2-21:2011)(Protection Against Access to Live Parts) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.10 of IS 302-2-21: 2011)(Power Input & Current) |
- |
1000 |
|
15 % Discount to BIS |
| (Cl.11 of 302-2-21:2011)(Heating) |
- |
1000 |
|
15 % Discount to BIS |
| (Cl.13 of IS 302-2-21:2011)(Leakage Current ) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.13 of IS 302-2-21:2011)(Electrical Strength at Operating Temperature) |
- |
1000 |
|
15 % Discount to BIS |
| (Cl.14ofIS302-2-21:2011)(Transient Over Voltages) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.15 of IS 302-2-21-2011)(Moisture Resistance) |
- |
1500 |
|
15 % Discount to BIS |
| (Cl.17 of IS 302-2-21:2011)(Overload protection of transformers & associated circuits) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.19 of IS 302-2-21:2011)(Abnormal Operation) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.20 of IS 302-2-21:2011)(Stability & Mechanical Hazards) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.21ofIS302-2-21:2011)(Mechanical strength) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
500 |
|
15 % Discount to BIS |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.24ofIS302-221:2011)(Component) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.27 of IS 302-2-21:2011)(Provision for Earthing) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.28 of IS 302-2-21:2011)(Screws & Connections) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.29ofIS302-2-21:2011)(Clearances, Creepage Distances and Solid Insulation) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.30 of IS 302-2-21:2011)(Resistance to Heat & Fire) |
- |
1000 |
|
15 % Discount to BIS |
| (Cl.31 of IS 302-2-21:2011)(Resistance to Rusting) |
- |
500 |
|
15 % Discount to BIS |
| 7.1(Marking : Rated Voltage ) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking : Symbol for nature of supply ) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking : Rated power input) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking: Name, trademark or identification mark of manufacturer ) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking: Model or type reference) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking: Symbol for Class II) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking: IP Number) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking : Country of manufacture) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking : Rated pressure) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking : Rated capacity) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking : Statement for a pressure-relief device) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking : Statement for pressure reducing valve ( For rated pressure less than 0.6 MPa)) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking : Warning for Open- outlet ) |
- |
0 |
|
Refer to clause 7 |
| 7.6(Marking : Symbol used ) |
- |
0 |
|
Refer to clause 7 |
| 7.8(Marking : Terminals ) |
- |
0 |
|
Refer to clause 7 |
| 7.11(Marking : Indication of controls ) |
- |
0 |
|
Refer to clause 7 |
| 7.13(Marking : Official language of Instruction ) |
- |
0 |
|
Refer to clause 7 |
| 7.14(Marking : Legibility and durability) |
- |
0 |
|
Refer to clause 7 |
| 7.101(Marking : Indifiction of water inlet and water outlet ) |
- |
0 |
|
Refer to clause 7 |
| Cl.8 of IS 302-2-21:2018(Protection Against Access to Live Parts) |
- |
0 |
|
Refer to clause 8 |
| Cl.10 of IS 302-2-21: 2018(Power Input & Current) |
- |
0 |
|
Refer to clause 10 |
| Cl.11 of 302-2-21:2018(Heating : Temp of Walls, ceilings and floor of the test corner ) |
- |
0 |
|
Refer to clause 11 |
| Cl.11 of 302-2-21:2018(Heating : Temp of Rubber or PVC insulation of internal and external wiring) |
- |
0 |
|
Refer to clause 11 |
| Cl.11 of 302-2-21:2018(Heating : Room Temp.) |
- |
0 |
|
Refer to clause 11 |
| Cl.13 of IS 302-2-21:2018(Leakage Current ) |
- |
0 |
|
refer to clause 13 |
| Cl.13 of IS 302-2-21:2018(3 Strength at Operating Temperature) |
- |
0 |
|
refer to clause 13 |
| Cl.14 of IS 302-2-21:2018(Transient Over Voltages) |
- |
0 |
|
refer to clause 14 |
| Cl.15 of IS 302-2-21-2018(Moisture Resistance) |
- |
0 |
|
refer to clause 15 |
| Cl.16 of IS 302-2-21-2018(Leakage current and Electric strength (After humidity): Leakage current ) |
- |
0 |
|
refer to clause 16 |
| Cl.16 of IS 302-2-21-2018(Leakage current and Electric strength (After humidity): Electric Strentgh ) |
- |
0 |
|
refer to clause 16 |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : emission of flame or molten metal or poisonous or ignitable gas ) |
- |
0 |
|
refer to clause 19 |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : Wall ceiling temp. of test corner ) |
- |
0 |
|
refer to clause 19 |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : Insulation of the supply cable or cord) |
- |
0 |
|
refer to clause 19 |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : High Voltage ) |
- |
0 |
|
refer to clause 19 |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : leakage from container during test) |
- |
0 |
|
refer to clause 19 |
| Cl.20 of IS 302-1:2008(Stability & Mechanical Hazards) |
- |
0 |
|
refer to clause 20 |
| Cl.21.1 of IS 302-1:2008(Mechanical strength : Rough handling in normal use) |
- |
21 |
|
refer to clause 21 |
| Cl.21.2 of IS 302-1:2008(Mechanical strength : prevent penetration by sharp implements. ) |
- |
0 |
|
refer to clause 21 |
| Cl.22.1 of
IS 302-1:2008(Construction : IP test ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.2 of
IS 302-1:2008(Construction : Provision to ensure all pole disconnection ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.6 of
IS 302-1:2008(Construction : Effect of water on 3 insulation ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.6 of
IS 302-2-21:2018(Construction : Size of drain hole ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.7 of
IS 302-1:2008(Construction: adequate safeguards against the risk of excessive pressure) |
- |
0 |
|
refer to clause 22 |
| Cl.22.11 of
IS 302-1:2008(Construction : Fixing of non detachable part ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.12 of
IS 302-1:2008(Construction : Fixing of Handle, knob, grips, levers and similar parts) |
- |
0 |
|
refer to clause 22 |
| Cl.22.14 of
IS 302-1:2008(Construction : ragged or sharp edges) |
- |
0 |
|
refer to clause 22 |
| Cl.22.17 of
IS 302-1:2008(Construction : Spacers ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.18 Of
IS 302-1:2008(Construction : Resistance to corrosion ) |
- |
0 |
|
refer to clause 22 |
| Cl 22.26 ,Cl.22.28, Cl 22.29, Cl 22.30 , Cl 22.31, Cl 22.32 of
IS 302-1:2008(Construction : Supplymentry/ double / reinforced insulation for Class II/ Class III appliance ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.33 of
IS 302-1:2008(Construction : Direct contact of liquids ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.34, Cl 22.35 of
IS 302-1:2008(Construction : Shaft of operating Knobs ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.44 of
IS 302-1:2008(Construction : Shape and decoration of enclosure) |
- |
0 |
|
refer to clause 22 |
| Cl.22.47 of
IS 302-2-21:2018 (Construction : Water pressure test ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.101 of
IS 302-2-21:2018(Construction : rated pressure of closed water heater ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.102 of
IS 302-2-21:2018(Construction : repeated drawing of water temp ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.103 of
IS 302-2-21:2018(Construction : Operation of Pressure relieve devices ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.104 of
IS 302-2-21:2018(Construction : Outlet of open outlet heater ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.106 of
IS 302-2-21:2018(Construction : Operation of thermal cut- out ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.107 of
IS 302-2-21:2018(Construction : Position of Heating elements and thermal control sensor) |
- |
0 |
|
refer to clause 22 |
| Cl.22.108 of
IS 302-2-21:2018(Construction : fixing to wall ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.109 of
IS 302-2-21:2018(Construction : Drain for appliance having a capacity of more than 15 liter) |
- |
0 |
|
refer to clause 22 |
| Cl.22.110 of
IS 302-2-21:2018(Construction : Material of Inner conatiner ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.110 of
IS 302-2-21:2018(Construction : meterial of connections ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.111 of
IS 302-2-21:2018(Construction : Resistance to vacuum ) |
- |
0 |
|
refer to clause 22 |
| Cl. 23 of IS 302-1:2008(Internal Wiring
) |
- |
0 |
|
refer to clause 23 |
| Cl. 23 of IS 302-1:2008(Internal Wiring : color identification for earthing conductor
) |
- |
0 |
|
refer to clause 23 |
| Cl.24of IS 302-221:2018(Component : Relevent Indian standards ) |
- |
0 |
|
refer to clause 24 |
| Cl.24.101 of IS302-221:2018(Component : Location of non self reseting thermal cut out ) |
- |
0 |
|
refer to clause 24 |
| Cl.24.102 of IS 302-221:2018(Component : Operation of thermal cut-out ) |
- |
0 |
|
refer to clause 24 |
| Cl.25 of IS 302-2-21:2018(Supply Connection & External Flexible Cords : connection to the supply mains) |
- |
0 |
|
refer to clause 25 |
| Cl.25.5 of IS 302-1:2008(Supply Connection & External Flexible Cords : Type of attachment ) |
- |
0 |
|
refer to clause 25 |
| Cl.25.8 of IS 302-2-21:2018(Supply Connection & External Flexible Cords : Resistance of supply cord ) |
- |
0 |
|
refer to clause 25 |
| Cl.25.10 of IS 302-1:2008(Supply Connection & External Flexible Cords : Colour of Earthing conductor ) |
- |
0 |
|
refer to clause 25 |
| Cl.25.12 of IS 302-1:2008(Supply Connection & External Flexible Cords : Moulding of supply cord ) |
- |
0 |
|
refer to clause 25 |
| Cl.25.15 of IS 302-1:2008(Supply Connection & External Flexible Cords : Cord grip test ) |
- |
0 |
|
refer to clause 25 |
| Cl.25.15 of IS 302-1:2008(Supply Connection & External Flexible Cords : Cord grip test - displacement ) |
- |
0 |
|
refer to clause 25 |
| Cl.25.18 of IS 302-1:2008(Supply Connection & External Flexible Cords) |
- |
0 |
|
refer to clause 25 |
| Cl.26 of IS 302-2-21: 2018(Terminals for External Conductors) |
- |
0 |
|
refer to clause 26 |
| Cl.27 of IS 302-2-21:2018(Provision for Earthing) |
- |
0 |
|
refer to clause 27 |
| Cl.27.5 of IS 302-1:2008(Provision for Earthing : ECR ) |
- |
0 |
|
refer to clause 27 |
| Cl.28 of IS 302-2-21:2018(Screws & Connections) |
- |
0 |
|
refer to clause 28 |
| Cl.29.1 of IS 302-1:2008(Clearances, Creepage Distances and Solid Insulation : Clearance distance ) |
- |
0 |
|
refer to clause 29 |
| Cl.29.2 of IS 302-1:2008(Clearances, Creepage Distances and Solid Insulation : Creepage distance ) |
- |
0 |
|
refer to clause 29 |
| Cl.30.1 of IS 302-1:2008(Resistance to Heat & Fire : Ball pressure test ) |
- |
0 |
|
refer to clause 30 |
| Cl.30.2 of IS 302-1:2008(Resistance to Heat & Fire : Glow wire test ) |
- |
0 |
|
refer to clause 30 |
| Cl.31 of IS 302-2-21:2018(Resistance to Rusting) |
- |
0 |
|
refer to clause 31 |
|
31 Dec, 2026 |
- Revised version included
w.e.f. 28.01.2019. |
| 14158 |
URS PRODUCTS AND TESTING PVT LTD (F3), NOIDA
| 8136826
| IS 1293 (2019) |
Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) |
- |
18000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Ratings) |
- |
100 |
|
15% discount to BIS |
| 7.1.1(Accessories Classification) |
- |
100 |
|
15% discount to BIS |
| 7.1.2(Accessories Classification) |
- |
100 |
|
15% discount to BIS |
| 7.1.3(Accessories Classification) |
- |
100 |
|
15% discount to BIS |
| 7.1.4(Accessories Classification) |
- |
100 |
|
15% discount to BIS |
| 7.1.5(Accessories Classification) |
- |
100 |
|
15% discount to BIS |
| 7.2.1(Socket-Outlets Classification) |
- |
100 |
|
15% discount to BIS |
| 7.2.2(Socket-Outlets Classification) |
- |
100 |
|
15% discount to BIS |
| 7.2.3(Socket-Outlets Classification) |
- |
100 |
|
15% discount to BIS |
| 7.2.4(Socket-Outlets Classification) |
- |
100 |
|
15% discount to BIS |
| 7.3(Plug Classification) |
- |
100 |
|
15% discount to BIS |
| 8.1(MARKING) |
- |
100 |
|
15% discount to BIS |
| 8.8(MARKING) |
- |
100 |
|
15% discount to BIS |
| 8.9(MARKING) |
- |
200 |
|
15% discount to BIS |
| 9.1(CHECKING OF DIMENSIONS) |
- |
100 |
|
15% discount to BIS |
| 9.2(CHECKING OF DIMENSIONS) |
- |
200 |
|
15% discount to BIS |
| 10.1(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
100 |
|
15% discount to BIS |
| 10.3(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
200 |
|
15% discount to BIS |
| 10.4(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
200 |
|
15% discount to BIS |
| 10.5(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
200 |
|
15% discount to BIS |
| 10.6(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
200 |
|
15% discount to BIS |
| 10.7(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
200 |
|
15% discount to BIS |
| 11.1(PROVISIONS FOR EARTHING) |
- |
200 |
|
15% discount to BIS |
| 11.2(PROVISIONS FOR EARTHING) |
- |
200 |
|
15% discount to BIS |
| 11.3(PROVISIONS FOR EARTHING) |
- |
200 |
|
15% discount to BIS |
| 11.4(PROVISIONS FOR EARTHING) |
- |
200 |
|
15% discount to BIS |
| 11.5(PROVISIONS FOR EARTHING) |
- |
200 |
|
15% discount to BIS |
| 11.6(PROVISIONS FOR EARTHING) |
- |
100 |
|
15% discount to BIS |
| 12.1.1(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.1.2(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.1(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.2(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.3(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.4(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.5(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.6(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.7(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.8(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.9(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.10(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.11(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.1(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.2(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.3(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.4(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.5(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.6(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.7(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.8(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.9(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.10(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.11(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.12(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 13.1(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.2(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.3(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.4(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.5(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.6(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.7(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.8(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.9(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.1(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.11(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.12(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.13(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.14(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.15(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.16(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.17(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.18(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.19(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.2(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.21(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.22(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.23(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.3(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.4(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.5(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.6(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.7(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.8(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.9(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.11(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.12(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.13(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.14(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.15(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.16(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.17(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.18(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.19(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.21(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.22(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.23(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.23.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.23.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.24(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.25(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.26(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 15(INTERLOCKED SOCKET-OUTLETS) |
- |
500 |
|
15% discount to BIS |
| 16.1(RESISTANCE TO AGEING,) |
- |
1000 |
|
15% discount to BIS |
| 16.2(RESISTANCE TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
500 |
|
15% discount to BIS |
| 16.3(Resistance to Humidity) |
- |
500 |
|
15% discount to BIS |
| 17.1(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
1000 |
|
15% discount to BIS |
| 17.2(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
500 |
|
15% discount to BIS |
| 17.3(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
500 |
|
15% discount to BIS |
| 18(OPERATION OF EARTHING CONTACTS) |
- |
500 |
|
15% discount to BIS |
| 19(TEMPERATURE RISE) |
- |
2000 |
|
15% discount to BIS |
| 20(BREAKING CAPACITY) |
- |
1500 |
|
15% discount to BIS |
| 21(NORMAL OPERATION) |
- |
500 |
|
15% discount to BIS |
| 22.1(Verification of the Maximum Withdrawal Force) |
- |
250 |
|
15% discount to BIS |
| 22.2(Verification of Minimum Withdrawal Force) |
- |
250 |
|
15% discount to BIS |
| 23.1(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
100 |
|
15% discount to BIS |
| 23.3(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
200 |
|
15% discount to BIS |
| 23.4(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
200 |
|
15% discount to BIS |
| 24.1(MECHANICAL STRENGTH
For all kinds of fixed socket-outlets
) |
- |
50 |
|
15% discount to BIS |
| 24.2(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
50 |
|
15% discount to BIS |
| 24.3(MECHANICAL STRENGTH
for fixed socket-outlets with a main part intended to be mounted directly on a surface) |
- |
50 |
|
15% discount to BIS |
| 24.4(MECHANICAL STRENGTH
For Plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
50 |
|
15% discount to BIS |
| 24.5(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
50 |
|
15% discount to BIS |
| 24.6(MECHANICAL STRENGTH
For screwed glands of accessories having an IP code higher than IP20) |
- |
50 |
|
15% discount to BIS |
| 24.7(MECHANICAL STRENGTH
For plug pins provided with insulating sleeves) |
- |
50 |
|
15% discount to BIS |
| 24.8(MECHANICAL STRENGTH
For shuttered socket-outlets) |
- |
50 |
|
15% discount to BIS |
| 24.9(MECHANICAL STRENGTH
For portable multiple and combined socket outlets
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
50 |
|
15% discount to BIS |
| 24.1(MECHANICAL STRENGTH
For Plug
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
50 |
|
15% discount to BIS |
| 24.11(MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
50 |
|
15% discount to BIS |
| 24.12(MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
50 |
|
15% discount to BIS |
| 24.13(MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
50 |
|
15% discount to BIS |
| 24.14.1(MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
50 |
|
15% discount to BIS |
| 24.14.2(MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
50 |
|
15% discount to BIS |
| 24.14.3(MECHANICAL STRENGTH
For plugs and portable socket-outlets) |
- |
50 |
|
15% discount to BIS |
| 24.15(MECHANICAL STRENGTH
) |
- |
50 |
|
15% discount to BIS |
| 24.16(MECHANICAL STRENGTH
For shroud of portable socket-outlets) |
- |
50 |
|
15% discount to BIS |
| 25.1(RESISTANCE TO HEAT
Accessories and surface mounting boxes) |
- |
250 |
|
15% discount to BIS |
| 25.2(RESISTANCE TO HEAT
Parts of insulating material necessary to retain
current-carrying parts of the earthing circuit in position,
as well as parts of the front surface zone of thermoplastic material) |
- |
250 |
|
15% discount to BIS |
| 25.3(RESISTANCE TO HEAT
Parts of insulating material not necessary to retain current-carrying parts and parts of the earthing circuit in position, even though they are in contact with them) |
- |
250 |
|
15% discount to BIS |
| 25.4(RESISTANCE TO HEAT
) |
- |
250 |
|
15% discount to BIS |
| 26.1(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
15% discount to BIS |
| 26.2(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
15% discount to BIS |
| 26.3(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
15% discount to BIS |
| 26.4(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
15% discount to BIS |
| 26.5(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
15% discount to BIS |
| 26.6(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
15% discount to BIS |
| 26.7(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
15% discount to BIS |
| 27.1(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
150 |
|
15% discount to BIS |
| 27.2(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
150 |
|
15% discount to BIS |
| 27.3(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
200 |
|
15% discount to BIS |
| 28.1.1(Resistance to Abnormal Heat and to Fire
Glow-Wire Test) |
- |
250 |
|
15% discount to BIS |
| 28.1.2(Resistance to Abnormal Heat and to Fire
for plugs with pins provided with insulating sleeves) |
- |
250 |
|
15% discount to BIS |
| 28.2(Resistance to Tracking
For accessories other than IP code higher than IPX0 parts of insulating material retaining live parts in position) |
- |
500 |
|
15% discount to BIS |
| 29(RESISTANCE TO RUSTING) |
- |
500 |
|
15% discount to BIS |
| 30.1(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Pressure Test at High Temperature) |
- |
150 |
|
15% discount to BIS |
| 30.2(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Static Damp Heat Test) |
- |
150 |
|
15% discount to BIS |
| 30.3(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Tests at Low Temperature) |
- |
100 |
|
15% discount to BIS |
| 30.4(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Impact Test at Low Temperature) |
- |
100 |
|
15% discount to BIS |
| 23.2(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
100 |
|
15% discount to BIS |
| 8.2(Marking) |
- |
100 |
|
15% discount to BIS |
| 8.3(Marking) |
- |
100 |
|
15% discount to BIS |
| 8.4(Marking) |
- |
100 |
|
15% discount to BIS |
| 8.5(Marking) |
- |
100 |
|
15% discount to BIS |
| 8.6(Marking) |
- |
100 |
|
15% discount to BIS |
| 8.7(Marking) |
- |
100 |
|
15% discount to BIS |
| 10.2(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
100 |
|
15% discount to BIS |
| 24.17(MECHANICAL STRENGTH) |
- |
100 |
|
15% discount to BIS |
| 24.18(MECHANICAL STRENGTH) |
- |
100 |
|
15% discount to BIS |
| 24.19(MECHANICAL STRENGTH) |
- |
100 |
|
15% discount to BIS |
| 21(NORMAL OPERATION) |
- |
500 |
|
15% discount to BIS |
|
31 Dec, 2026 |
- Included w.e.f. 24-07-2020. |
| 14159 |
URS PRODUCTS AND TESTING PVT LTD (F3), NOIDA
| 8136826
| IS 369 (2019) |
Household electric direct - Acting room heaters - Performance requirements (Fourth Revision) |
Not Applicable |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 of IS 302-2-30:2007(Classification) |
- |
100 |
|
15% discount to BIS |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
100 |
|
15% discount to BIS |
| Cl.8 of IS 302-2-30:2007 &IS:302-1:2008(Protection Against Access to Live Parts) |
- |
100 |
|
15% discount to BIS |
| Cl.10 of IS 302-2-30:2007 &IS:302-1:2008(Power Input and Current) |
- |
100 |
|
15% discount to BIS |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
100 |
|
15% discount to BIS |
| Cl.13 of IS 302-2-30:2007 &IS:302-1:2008(Leakage Current & Electric Strength at operating temp) |
- |
100 |
|
15% discount to BIS |
| Cl.14 of IS 302-2-30:2007 &IS:302-1:2008(Transient Over Voltages) |
- |
100 |
|
15% discount to BIS |
| Cl.15 of IS 302-2-30:2007 &IS:302-1:2008(Moisture Resistance) |
- |
100 |
|
15% discount to BIS |
|
31 Dec, 2026 |
- - |
| 14160 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 3196 : Part 2 (2006) |
Welded low carbon steel cylinders exceeding 5 litre water capacity for low pressure liquefiable gases: Part 2 cylinders for liquefiable non - Toxic gases other than lpg - Specification (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 19 (Marking) |
- |
|
|
|
| 9 (Valve Connection) |
- |
|
|
|
| 9 (Valve Protection) |
- |
|
|
|
| 9 (Valve Protection) |
- |
|
|
|
| 9 (Valve Protection) |
- |
|
|
|
| 10 (Handle) |
- |
|
|
|
| 10 (Foot ring) |
- |
|
|
|
| 10 (Foot ring) |
- |
|
|
|
| 10 (Foot ring) |
- |
|
|
|
| 10.3 (Bung) |
- |
|
|
|
| 14 (Water Capacity) |
- |
|
|
|
| 16 (Pneumatic Leakage Test) |
- |
|
|
|
| 18.1.3 (Root Bend test,) |
- |
|
|
|
| 18.1.3 (Face Bend Test,) |
- |
|
|
|
| 18.1.5 (Minimum Thickness test) |
- |
|
|
|
| 20 (Colour Identification) |
- |
|
|
|
| 10.3 (Bung) |
- |
|
|
|
|
- |
- 2nos
Excluding except material test, Hydrostatic stretch test,RADIOGRAPHIC EXAMINATION (Prepared Test piece needed for Acceptance Test). Test facility for hydrostatic test is limited to 360Kg/cm2 pressure. |