| 9451 |
Avon Food Lab Pvt. Ltd.
| 8117816
| IS 17945 (2022) |
FOOD FOR SPECIAL MEDICAL PURPOSE INTENDED FOR INFANTS � SPECIFICATION |
- |
85300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Description - IS 17945) |
- |
100 |
|
- |
| 5.4(Scorched Particles - IS 13500) |
- |
200 |
|
- |
| 5.11,Table 1(i)(Energy - IS 17945) |
- |
1000 |
|
- |
| 5.11,Table 1(ii)(Total Protein - IS 7219) |
- |
700 |
|
- |
| 5.11,Table 1(iii)((a)Total Fat - IS 11721) |
- |
600 |
|
- |
| 5.11,Table 1(iii)((b)Linoleic acid -Annex B of IS 14433 or ISO 16958 or ILL/STP/INST/026) |
- |
500 |
|
- |
| 5.11,Table 1(iii)((c)alpha Linoleic acid Annex B of IS 14433 or ISO 16958 or ILL/STP/INST/026) |
- |
500 |
|
- |
| 5.11,Table 1(iv)(Docosahexaaenoic (DHA) - ISO 16958 or ILL/STP/INST/026) |
- |
500 |
|
- |
| 5.11,Table 1(v)(Eicosapentaenoic acid (EPA) - IS 14433 or ISO or ILL/STP/INST/026) |
- |
500 |
|
- |
| 5.11,Table 1(vi)(Arachidonic acid(ARA) ISO 16958 or ILL/STP/INST/026) |
- |
500 |
|
- |
| 5.11,Table 1(vii)(Carbohydrate -Annex C of IS 1656) |
- |
500 |
|
- |
| 5.11,Table 1(viii)(Sodium-IS 12760 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
600 |
|
- |
| 5.11,Table 1(ix)(Potassium - IS 12760 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
600 |
|
- |
| 5.11,Table 1(x)(Calcium -IS 12760 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.11,Table 1(xi)(Phosphate - IS 12756 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
700 |
|
- |
| 5.11,Table 1(xii)(Chloride - IS 11763 or AOAC 2013.03) |
- |
500 |
|
- |
| 5.11,Table 1(xiii)(Magnesium -IS 12760 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
700 |
|
- |
| 5.11,Table 1(xiv)(Iron - ISO 15151 or ISO 21424 or AOAC 985.35 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.11,Table 1(xv)(Zinc- 15 of IS 1699 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.11,Table 1(xvi)(Copper - 15 of IS 1699 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.11,Table 1(xvii)(Selenium -IS 15303 or ISO 15151 or ISO 20649 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.11,Table 1(xviii)(Manganese - ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.11,Table 1(xix)(Iodine- IS 17379 or ILL/STP/INST/ICP/001) |
- |
600 |
|
- |
| 5.7, Table 1 (xx)(Chromium -ISO 20649 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.7, Table 1 (xxi)(Molybdenum - ISO 20649 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.11,Table 1(xxii)(Thiamine - IS 17669 or ILL/STP/INST/013) |
- |
1800 |
|
- |
| 5.11,Table 1(xxiii)(Riboflavin - IS 17669 or ILL/STP/INST/013) |
- |
1800 |
|
- |
| 5.11,Table 1(xxiv)(Niacin Equivalent - IS17669 or ILL/STP/INST/013) |
- |
1800 |
|
- |
| 5.11,Table 1(xxv)(Pantothenic acid - IS 16642 or ILL/STP/INST/014) |
- |
1800 |
|
- |
| 5.11,Table 1(xxvi)(Pyridoxine - IS17669 or ILL/STP/INST/013) |
- |
1800 |
|
- |
| 5.11,Table 1(xxvii)(Cobalamin - IS 16640 or AOAC 2014.02 or AOAC 2013.19 or ILL/STP/INST/013) |
- |
1800 |
|
- |
| 5.11,Table 1(xxviii)(Folic Acid - AOAC 2013.13 or ILL/STP/INST/013) |
- |
2000 |
|
- |
| 5.11,Table 1(xxix)(L-Ascorbic Acid (Vitamin C) - 5838 or IS 17176 or ILL/STP/INST/HPLC/022) |
- |
1500 |
|
- |
| 5.11,Table 1(xxx)(Biotin - IS 17670 or ILL/STP/INST/015) |
- |
1800 |
|
- |
| 5.11,Table 1(xxxi)(Vitamin A (as retinol equivalent RE) -IS 16639 or ILL/STP/INST/011) |
- |
1500 |
|
- |
| 5.11,Table 1(xxxii)(Vitamin D - IS 17177 or ILL/STP/INST/012) |
- |
2500 |
|
- |
| 5.11,Table 1(xxxiii)(Vitamin E (as alpha tocopherol equivalent)only for type II - IS 16639 or ILL/STP/INST/011) |
- |
2500 |
|
- |
| 5.11,Table 1(xxxiv)(Vitamin K - IS 21446 or ILL/STP/INST/011) |
- |
1500 |
|
- |
| 5.11,Table 1(xxxv)(Choline - IS 17668 or ILL/STP/INST/016) |
- |
2200 |
|
- |
| 5.7, Table 1 (xxxvi)(Inositol- IS 16649 or ILL/STP/INST/047) |
- |
3000 |
|
- |
| "5.12 Table 2 (i) "(Aerobic plate count-IS 5402 (Part 1)) |
- |
500 |
|
- |
| "5.12 Table 2 (ii)"(Staphylococcuus aureus-IS 5887 (Part 8/Sec-1)) |
- |
700 |
|
- |
| "5.12 Table 2 (iii)"(Yeast & mould count-IS 5403) |
- |
500 |
|
- |
| "5.12 Table 2 (iv)"(Salmonella sp.-IS 5887 (Part 3)) |
- |
700 |
|
- |
| "5.12 Table 2 (v)"(Listeria monocytogenes-IS 14988 (Part 1)) |
- |
700 |
|
- |
| v(Bacillus cereus-IS 5887 (Part 6)) |
- |
500 |
|
- |
| "5.12 Table 2 (vii)"(Sulphite reducing clostridia-ISO 15213) |
- |
700 |
|
- |
| "5.12 Table 2 (viii)"(Enterobacteriacae-is 17112(p-1)) |
- |
600 |
|
- |
| "5.12 Table 2 (ix)"(Enterobacter Sakazakii(Cronobacter spp.)-ISO 22964) |
- |
1500 |
|
- |
| 5.14(Lead - IS 12074 or AOAC 2015.01 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.14(Arsenic - IS 11124 or AOAC 2015.01 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.14(Tin - ISO 14377 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.14(Cadmium - 15 of IS 1699 or AOAC 2015.01 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.14(Melamine -IS 16195 or ILL/STP/INST/LC/007) |
- |
2000 |
|
- |
| 5.16 & 5.16.1.5(Optional Requirement for ECO MARK Vibrio cholerae & Vibrio parahaemolyticus IS 5887 Part-5) |
- |
1200 |
|
- |
| 6.1.1(Bisphenol A (BPA)) |
- |
5500 |
|
- |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Carotenes (Optional Parameter) - IS 17671 or ILL/STP/INST/050) |
- |
2000 |
|
- |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Amino acid (Optional Parameter)-AOAC 2018.06 or ILL/STP/INST/028) |
- |
12000 |
|
- |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Nucleotides (Optional Parameter)-IS 16641 or ILL/STP/INST/051) |
- |
8000 |
|
- |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(L-Carnitine (Optional Parameter)-IS 17668 or ILL/STP/INST/051) |
- |
2000 |
|
- |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Taurine (Optional Parameter)-AOAC 2018.06 or AOAC 997.05 or ILL/STP/INST/028) |
- |
1800 |
|
- |
|
19 Feb, 2027 |
- Included w.e.f. 08.12.2023 |
| 9452 |
Avon Food Lab Pvt. Ltd.
| 8117816
| IS 1656 (2022) |
MILK-CEREAL BASED COMPLEMENTARY FOODS SPECIFICATION (Fifth Revision of IS 1656) |
NA |
68800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Description - IS 1656) |
- |
100 |
|
- |
| 4.2(Free from scorched particles - IS 1656) |
- |
200 |
|
- |
| 4.5,Table 1(i)((Optional Ingredients)Pantothenic acid - IS 16642) |
- |
1800 |
|
- |
| 4.5,Table 1(ii)((Optional Ingredients) Vitamin B12 - IS 16640 or AOAC 2014.02) |
- |
1800 |
|
- |
| 4.5,Table 1(iii)((Optional Ingredients) Vitamin K - IS 21446) |
- |
1500 |
|
- |
| 4.5,Table 1(iv)((Optional Ingredients) Choline - IS 17668) |
- |
2200 |
|
- |
| 4.5,Table 1(v)((Optional Ingredients) Inositol - 16649 or any other validated international method) |
- |
3000 |
|
- |
| 4.5,Table 1(vi)((Optional Ingredients) Calcium -IS 12760 or ISO 15151 or ISO 21424) |
- |
500 |
|
- |
| 4.5,Table 1(vii)((Optional Ingredients) Phosphorus-IS 12756 or ISO 15151 or ISO 21424) |
- |
700 |
|
- |
| 4.5,Table 1(viii)((Optional Ingredients) Chloride - IS 11763 or AOAC 2013.03) |
- |
500 |
|
- |
| 4.5,Table 1(ix)((Optional Ingredients) Magnesium- IS 12760 or ISO 15151 or ISO 21424) |
- |
500 |
|
- |
| 4.5,Table 1(x)((Optional Ingredients) Sodium-IS 12760 or ISO 15151 or ISO 21424) |
- |
600 |
|
- |
| 4.5,Table 1(xi)((Optional Ingredients) Selenium-IS 15303 or ISO 15151 or ISO 20649) |
- |
500 |
|
- |
| 4.5,Table 1(xii)((Optional Ingredients) Taurine-AOAC 2018.06 or AOAC 997.05) |
- |
1800 |
|
- |
| 4.5,Table 1(xiii)((Optional Ingredients) L-amino acids-AOAC 2018.06) |
- |
12000 |
|
- |
| 4.5,Table 1(xiv)((Optional Ingredients) L-Carnitine - IS 17668) |
- |
2000 |
|
- |
| 4.5,Table 1(xv)((Optional Ingredients) Biotin- IS 17670) |
- |
1800 |
|
- |
| Clause 4.5,Table 1 ,Sl No xvi)(Iodine) |
- |
600 |
|
- |
| 4.5,Table 1(xvii)((Optional Ingredients) Potassium - IS 12760 or ISO 15151 or ISO 21424) |
- |
600 |
|
- |
| 4.5,Table 1(xviii)((Optional Ingredients) Pyridoxine -IS 17669) |
- |
1800 |
|
- |
| 4.8,Table 2(i)(Moisture -IS 11623/IS 16072) |
- |
350 |
|
- |
| 4.8,Table 2(ii)(Protein, a) Total Protein including milk protein - IS 11917) |
- |
700 |
|
- |
| 4.8,Table 2(ii)(Protein, b)Milk protein - IS 11917) |
- |
700 |
|
- |
| 4.8,Table 2(iii)(Fat a)Total Fat, including mlk fat - Annex B IS 1656) |
- |
600 |
|
- |
| 4.8,Table 2(iii)(Fat b)Milk fat - Annex B IS 1656) |
- |
600 |
|
- |
| 4.8,Table 2(iv)(Total carbohydrate -Annex C IS 1656) |
- |
500 |
|
- |
| 4.8,Table 2(v)(Total Ash - Annex C IS 14433) |
- |
450 |
|
- |
| 4.8,Table 2(vi)(Acid insoluble ash in dilute hydrochloric acid- Annex D IS 14433) |
- |
500 |
|
- |
| 4.8,Table 1(vii)(Vitamin A (as retinol equivalent RE) IS 16639) |
- |
1500 |
|
- |
| 4.8,Table 1(viii)(Vitamin C - 5838 or IS 17176) |
- |
1500 |
|
- |
| 4.8,Table 1(ix)(Iron - ISO 15151 or ISO 21424 or AOAC 985.35) |
- |
500 |
|
- |
| 4.8,Table 1(x)(Crude fibre (On dry basis) - IS 10226(P-1)) |
- |
800 |
|
- |
| 4.8,Table 1(xi)(Vitamin D - IS 17177) |
- |
2500 |
|
- |
| 4.8,Table 1(xii)(Thiamine - IS 17669) |
- |
0 |
|
- |
| 4.8,Table 1(xiii)(Riboflavin - IS 17669) |
- |
1800 |
|
- |
| 4.8,Table 1(xiv)(Niacin Equivalent - IS17669) |
- |
1800 |
|
- |
| 4.5,Table 1(xv)(Dietary Folate equivalent(DFE) - 2013.03) |
- |
2500 |
|
- |
| 4.8,Table 1(xvi)(Zinc- 15 of IS 1699 or ISO 15151 or ISO 21424) |
- |
500 |
|
- |
| 4.8,Table 1(i)(Lead - IS 12074 or AOAC 2015.01) |
- |
500 |
|
- |
| 4.8,Table 1(ii)(Copper - 15 of IS 1699 or ISO 15151 or ISO 21424) |
- |
500 |
|
- |
| 4.8,Table 1(ii)(Arsenic - IS 11124 or AOAC 2015.01) |
- |
500 |
|
- |
| Clause 4.11,Table 4 ,Sl No iv)(Tin) |
- |
500 |
|
- |
| 4.8,Table 1(iv)(Cadmium - 15 of IS 1699 or AOAC 2015.01) |
- |
500 |
|
- |
| 4.8,Table 1(v)(Melamine -IS 16195) |
- |
2000 |
|
- |
| "4.8 Table 3 (i) "(Aerobic plate count-IS 5402 (Part 1)) |
- |
500 |
|
- |
| "4.8 Table 3 (ii) "(Coliform count-IS 5401 (Part 1)) |
- |
500 |
|
- |
| "4.8 Table 3 (iii) "(Staphylococcuus aureus-IS 5887 (Part 2)) |
- |
700 |
|
- |
| "4.8 Table 3 (iv) "(Yeast & mould count-IS 5403) |
- |
500 |
|
- |
| "4.8 Table 3 (v) "(Salmonella sp.-IS 5887 (Part 3)) |
- |
700 |
|
- |
| Clause 4.8,Table 3, ,Sl No vi)(Listeria monocytogenes) |
- |
700 |
|
- |
| "4.8 Table 3 (vii) "(Bacillus cereus-IS 5887 (Part 6)) |
- |
500 |
|
- |
| "4.8 Table 3 (viii) "(Sulphite reducing clostridia-ISO 15213) |
- |
700 |
|
- |
| "4.8 Table 3 (ix) "(Escherichia coli-IS 5887 (Part 1)) |
- |
500 |
|
- |
| 4.13 Subclause 4.13.1.5(Vibrio cholerae & Vibrio parahaemolyticus) |
- |
1200 |
|
- |
| 5.1.1(Bisphenol A (BPA)) |
- |
5500 |
|
- |
|
19 Feb, 2027 |
- Included w.e.f. 08.12.2023 |
| 9453 |
Avon Food Lab Pvt. Ltd.
| 8117816
| IS 1166 (2022) |
SWEETENED CONDENSED MILK, SWEETENED CONDENSED PARTLY SKIMMED MILK, SWEETENED CONDENSED SKIMMED MILK AND SWEETENED CONDENSD HIGH FAT MILK- SPECIFICATION (Third Revision of IS 1166) |
- |
31200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2(Taste , Flavour,Colour & Odour. Free from rancid , fruity , moldy , tallowy , cooked , sour, sandy and any other objectionable odour and taste -IS 1166) |
- |
100 |
|
- |
| 4.6(Size of lactose crystals- IS 1166) |
- |
300 |
|
- |
| "4.7 Table 2 (i) "(Aerobic plate count-IS 5402 (Part 1)) |
- |
500 |
|
- |
| "4.7 Table 2 (ii) "(Coliform count-IS 5401 (Part 1)) |
- |
500 |
|
- |
| "4.7 Table 2 (iii) "(Staphylococcuus aureus-IS 5887 (Part 8/Sec-1)) |
- |
700 |
|
- |
| "4.7 Table 2 (iv) "(Yeast & mould count-IS 5403) |
- |
500 |
|
- |
| "4.7 Table 2 (v) "(Salmonella sp.-IS 5887 (Part 3/Sec-1)) |
- |
700 |
|
- |
| "4.7 Table 2 (vi) "(Listeria monocytogenes-IS 14988 (Part 1)) |
- |
700 |
|
- |
| "4.7 Table 2 (vii) "(Escherichia coli-IS 5887 (Part 1)) |
- |
700 |
|
- |
| 4.1,Table 1(i)(Total milk solids - IS 1166) |
- |
500 |
|
- |
| 4.1,Table 1(ii)(Milk Fat -IS 11721) |
- |
600 |
|
- |
| 4.1,Table 1(iii)(Milk solid not fat- IS1166) |
- |
700 |
|
- |
| 4.1,Table 1(iv)(Milk protein in milk solids not fat IS -11917) |
- |
700 |
|
- |
| 4.1,Table 1(v)(Accelerated Storage Test -IS 1166) |
- |
3000 |
|
- |
| 4.8(2,4-Dichlorophenoxy Acetic acid) |
- |
8000 |
|
- |
| 4.8(Acephate (expressed as mixture of Methamidophos and acephate)) |
- |
0 |
|
- |
| 4.8(Acetamiprid) |
- |
0 |
|
- |
| 4.8(Azoxystrobin) |
- |
0 |
|
- |
| 4.8(Sum of benomyl & carbendazim expressed as carbendazim)) |
- |
0 |
|
- |
| 4.8(Bifenthrin) |
- |
0 |
|
- |
| 4.8(Bitertanol) |
- |
0 |
|
- |
| 4.8(Buprofezin) |
- |
0 |
|
- |
| 4.8(Carbaryl) |
- |
0 |
|
- |
| 4.8(Carbendazim) |
- |
0 |
|
- |
| 4.8(Carbofuran (sum of carbofuran & 3-hydroxy carbofuran expressedas carbofuran)) |
- |
0 |
|
- |
| 4.8(Chlorantraniliprole) |
- |
0 |
|
- |
| 4.8(Chlorothalonil) |
- |
0 |
|
- |
| 4.8(Chlorpyriphos) |
- |
0 |
|
- |
| 4.8(Chlothianidin (Chlothianidin & its metabolite Thiazolymethylguanidine(TMG) ,Thiazolymethylurea(TZMU),Methylnitroguanidine(MNG)) |
- |
0 |
|
- |
| 4.8(Cypermethrin (sum of isomers) (Fat soluble residue)) |
- |
0 |
|
- |
| 4.8(Deltamethrin (Decamethrin)) |
- |
0 |
|
- |
| 4.8(Dichlorvos (DDVP) (content of dichloroacetaldehyde (D.C.A.)) |
- |
0 |
|
- |
| 4.8(Difenoconazole) |
- |
0 |
|
- |
| 4.8(Dimethoate) |
- |
0 |
|
- |
| 4.8(Dinotefuron) |
- |
0 |
|
- |
| 4.8(Mancozeb) |
- |
0 |
|
- |
| 4.8(metiram as CS2) |
- |
0 |
|
- |
| 4.8(Edifenphos) |
- |
0 |
|
- |
| 4.8(Emamectin Benzoate) |
- |
0 |
|
- |
| 4.8(Spectinomycin) |
- |
8000 |
|
- |
| 4.8(Sulfadiazine) |
- |
0 |
|
- |
| 4.8(Sulfanilamide) |
- |
0 |
|
- |
| 4.8(Sulfaquinoxaline) |
- |
0 |
|
- |
| 4.8(Sulfadimidine) |
- |
0 |
|
- |
| 4.8(Sulfa Chloropyrazine) |
- |
0 |
|
- |
| 4.8(Thiabendazole) |
- |
0 |
|
- |
| 4.8(Trimethoprim) |
- |
0 |
|
- |
| 4.8(Tylosin) |
- |
0 |
|
- |
| 4.8(Virginiamycin) |
- |
0 |
|
- |
| 4.9,Table 3(i)(Lead -IS 12074) |
- |
500 |
|
- |
| 4.9,Table 3(ii)(Arsenic - IS 11124) |
- |
500 |
|
- |
| 4.9,Table 3(iv)(Melamine - IS 16195) |
- |
2000 |
|
- |
| 4.9,Table 3(iii)(Aflatoxin M1 - ISO 14501 or ISO 14674 or any other international validated method) |
- |
2000 |
|
- |
|
19 Feb, 2027 |
- Revised Version of IS 1166:2022. Included w.e.f. 17.05.2023 |
| 9454 |
Avon Food Lab Pvt. Ltd.
| 8117816
| IS 1165 (2022) |
WHOLE MILK POWDER - SPECIFICATION (Sixth Revision of IS 1165) |
NA |
37300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Discription) |
- |
100 |
|
- |
| 3.2(Flavour and Taste) |
- |
100 |
|
- |
| 3.3(extraneous matter) |
- |
100 |
|
- |
| 3.5, Table 1 (i)(Moisture -IS 16072/IS 11623) |
- |
350 |
|
- |
| 3.5, Table 1 (ii)(Total solids -IS 16072/IS 11623) |
- |
500 |
|
- |
| 3.5, Table 1 (iii)(Milk Fat -IS 11721/IS 1224(P-2)) |
- |
600 |
|
- |
| 3.5, Table 1 (iv)(Milk protein in milk solids not fat-IS 11917) |
- |
700 |
|
- |
| 3.5, Table 1 (v)(Insolubility index - IS 12759) |
- |
350 |
|
- |
| 3.5, Table 1 (vi)(Total ash (on dry basis) - IS1165) |
- |
500 |
|
- |
| 3.5, Table 1 (vii)(Titratable acidity (lactic acid), as ml of 0.1 N NaOH /10g solids not fat - IS 11765) |
- |
300 |
|
- |
| 3.5, Table 1 (viii)(Scorched Particles - IS 13500) |
- |
200 |
|
- |
| "3.5 Table 2 (i) "(Aerobic plate count-IS 5402 (Part 1):2021) |
- |
500 |
|
- |
| "3.5 Table 2 (ii) "(Coliform count-IS 5401 (Part 1):2012) |
- |
500 |
|
- |
| "3.5 Table 2 (iii) "(Staphylococcuus aureus-IS 5887 (Part 8/Sec-1)) |
- |
700 |
|
- |
| "3.5 Table 2 (iv) "(Yeast & mould count-IS 5403) |
- |
500 |
|
- |
| "3.5 Table 2 (v) "(Salmonella sp.-IS 5887 (Part 3/ Section -1)) |
- |
700 |
|
- |
| "3.5 Table 2 (vi) "(Listeria monocytogenes-IS 14988 (Part 1)) |
- |
700 |
|
- |
| "3.5 Table 2 (vii) "(Bacillus cereus-IS 5887 (Part 6)) |
- |
700 |
|
- |
| "3.5 Table 2 (viii) "(Sulphite reducing clostridia-ISO 15213) |
- |
700 |
|
- |
| "3.5 Table 2 (ix) "(Escherichia coli-IS 5887 (Part 1)) |
- |
500 |
|
- |
| 3.6(2,4-Dichlorophenoxy Acetic acid) |
- |
8000 |
|
- |
| 3.6(Acephate (expressed as mixture of Methamidophos and acephate)) |
- |
0 |
|
- |
| 3.6(Acetamiprid) |
- |
0 |
|
- |
| 3.6(Azoxystrobin) |
- |
0 |
|
- |
| 3.6(Sum of benomyl & carbendazim expressed as carbendazim)) |
- |
0 |
|
- |
| 3.6(Chlorantraniliprole) |
- |
0 |
|
- |
| 3.6(Chlorothalonil) |
- |
0 |
|
- |
| 3.6(Chlorpyriphos) |
- |
0 |
|
- |
| 3.6(Chlothianidin (Chlothianidin & its metabolite Thiazolymethylguanidine(TMG) ,Thiazolymethylurea(TZMU),Methylnitroguanidine(MNG)) |
- |
0 |
|
- |
| 3.6(Cypermethrin (sum of isomers) (Fat soluble residue)) |
- |
0 |
|
- |
| 3.6(Deltamethrin (Decamethrin)) |
- |
0 |
|
- |
| 3.6(Bifenthrin) |
- |
0 |
|
- |
| 3.6(Bitertanol) |
- |
0 |
|
- |
| 3.6(Buprofezin) |
- |
0 |
|
- |
| 3.6(Carbaryl) |
- |
0 |
|
- |
| 3.6(Carbendazim) |
- |
0 |
|
- |
| 3.6(Dichlorvos (DDVP) (content of dichloroacetaldehyde (D.C.A.)) |
- |
0 |
|
- |
| 3.6(Difenoconazole) |
- |
0 |
|
- |
| 3.6(Dimethoate) |
- |
0 |
|
- |
| 3.6(Dinotefuron) |
- |
0 |
|
- |
| 3.6(Mancozeb) |
- |
0 |
|
- |
| 3.6(metiram as CS2) |
- |
0 |
|
- |
| 3.6(Edifenphos) |
- |
0 |
|
- |
| 3.6(Emamectin Benzoate) |
- |
0 |
|
- |
| 3.6(Ethion (Residues to be determined as ethion & its oxygen analogue and expressed as ethion)) |
- |
0 |
|
- |
| 3.6(Ethofenprox (Etofenprox)) |
- |
0 |
|
- |
| 3.6(Fenpropathrin) |
- |
0 |
|
- |
| 3.6(Fenvalerate (fat soluble residue)) |
- |
0 |
|
- |
| 3.6(Fipronil) |
- |
0 |
|
- |
| 3.6(Flubendiamide) |
- |
0 |
|
- |
| 3.6(Flusilazole) |
- |
0 |
|
- |
| 3.6(Glufosinate Ammonium) |
- |
0 |
|
- |
| 3.6(Imidacloprid) |
- |
0 |
|
- |
| 3.6(Indoxacarb) |
- |
0 |
|
- |
| 3.6(Kresoxim Methyl) |
- |
0 |
|
- |
| 3.6(Methomyl) |
- |
0 |
|
- |
| 3.6(Methyl Chlorophenoxy Acetic Acid (MCPA)) |
- |
0 |
|
- |
| 3.6(Metolachlor) |
- |
0 |
|
- |
| 3.6(Monocrotophos) |
- |
0 |
|
- |
| 3.6(Oxydemeton-Methyl) |
- |
0 |
|
- |
| 3.6(Paraquat dichloride (Determined as Paraquatcations)) |
- |
0 |
|
- |
| 3.6(Penconazole) |
- |
0 |
|
- |
| 3.6(Phenthoate) |
- |
0 |
|
- |
| 3.6(Phorate (sum of phorate,its oxygen analogue and their sulphoxides & sulphones, expressed as Phorate)) |
- |
0 |
|
- |
| 3.6(Pirimiphos-methyl) |
- |
0 |
|
- |
| 3.6(Propiconazole) |
- |
0 |
|
- |
| 3.6(Pyraclostrobin) |
- |
0 |
|
- |
| 3.6(Tebuconazole) |
- |
0 |
|
- |
| 3.6(Thiacloprid) |
- |
0 |
|
- |
| 3.6(Thiophanate-Methyl) |
- |
0 |
|
- |
| 3.6(Thiamethoxam) |
- |
0 |
|
- |
| 3.6(Triacontanol) |
- |
0 |
|
- |
| 3.6(Triadimefon) |
- |
0 |
|
- |
| 3.6(Trichlorfon) |
- |
0 |
|
- |
| 3.6("Antibiotic and Veterinary drug residues
") |
- |
15000 |
|
- |
| 3.6(Ampicillin) |
- |
0 |
|
- |
| 3.6(Apramycin) |
- |
0 |
|
- |
| 3.6(Albendazole) |
- |
0 |
|
- |
| 3.6(Chlotetracycline/Oxytetracycline/Tetracycline) |
- |
0 |
|
- |
| 3.6(Ceftiofur) |
- |
0 |
|
- |
| 3.6(Cefphactril) |
- |
0 |
|
- |
| 3.6(Doramectin) |
- |
0 |
|
- |
| 3.6(Diminazene) |
- |
0 |
|
- |
| 3.6(Flunixin) |
- |
0 |
|
- |
| 3.6(Febantel/Fenbendazole/Oxyfendazole) |
- |
0 |
|
- |
| 3.6(Ivermectin) |
- |
0 |
|
- |
| 3.6(Lincomycin) |
- |
0 |
|
- |
| 3.6(Monensin) |
- |
0 |
|
- |
| 3.6(Meloxicam) |
- |
0 |
|
- |
| 3.6(Neomycin) |
- |
0 |
|
- |
| 3.6(Oxyclozanide) |
- |
0 |
|
- |
| 3.6(Parbendazole) |
- |
0 |
|
- |
| 3.6(Praziquantel) |
- |
0 |
|
9 |
| 3.6(Spectinomycin) |
- |
0 |
|
- |
| 3.6(Sulfadiazine) |
- |
0 |
|
- |
| 3.6(Sulfanilamide) |
- |
0 |
|
- |
| 3.6(Sulfa Chloropyrazine) |
- |
0 |
|
- |
| 3.6(Thiabendazole) |
- |
0 |
|
- |
| 3.6(Trimethoprim) |
- |
0 |
|
- |
| 3.6(Tylosin) |
- |
0 |
|
- |
| 3.6(Virginiamycin) |
- |
0 |
|
- |
| 3.7, Table 3 (i)(Lead -IS 12074) |
- |
500 |
|
- |
| 3.7, Table 3 (ii)(Arsenic - IS 11124) |
- |
500 |
|
- |
| 3.7, Table 3 (iii)(Aflatoxin M1 - ISO 14501 or ISO 14674 or any other international validated method) |
- |
2000 |
|
- |
| 3.7, Table 3 (iv)(Melamine - IS 16195) |
- |
2000 |
|
- |
|
19 Feb, 2027 |
- Revised Version of IS 1165:2022. Included w.e.f. 16.05.2023 |
| 9455 |
Avon Food Lab Pvt. Ltd.
| 8117816
| IS 7224 (2006) |
Iodized salt, vacuum evaporated iodized salt and refined iodized salt - Specification (Second Revision) |
refined Iodized salt/vacuum evaporated iodized/iodized |
7440 View breakup
Rs.7440/- (For both refined iodized salt/Vacuum Evaporated iodized salt and iodized salt)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.2(Particle Size) |
- |
300 |
|
NA |
| Clause 4.3 Table 1(Moisture content) |
- |
300 |
|
NA |
| Clause 4.3 Table 1(water insoluble matter) |
- |
500 |
|
NA |
| Clause 4.3 Table 1(Chloride Content(as Nacl)) |
- |
600 |
|
NA |
| Clause 4.3 Table 1(Matter soluble in water other than sodium chloride) |
- |
500 |
|
NA |
| Clause 4.3 Table 1(Calcium (as Ca)) |
- |
500 |
|
NA |
| Clause 4.3 Table 1(Magnesium (as mg)) |
- |
500 |
|
NA |
| Clause 4.3 Table 1(Sulphate (as SO4 ),) |
- |
500 |
|
NA |
| Clause 4.3 Table 1(Iodine content, a) Manufacturers Level ) |
- |
0 |
|
NA |
| Clause 4.3 Table 1(b) Distribution channel including retailer) |
- |
800 |
|
NA |
| Clause 4.3 Table 1(Alkalinity (as Na2CO3),) |
- |
640 |
|
NA |
| Clause 4.3 Table 1(Lead as (Pb)) |
- |
500 |
|
NA |
| Clause 4.3 Table 1(Arsenic(as As)) |
- |
500 |
|
NA |
| Clause 4.3 Table 1(Iron(as Fe)) |
- |
500 |
|
NA |
| 4.4(Anticaking agents (Potassium Ferrocyanide)) |
- |
800 |
|
NA |
|
19 Feb, 2027 |
- - |
| 9456 |
Avon Food Lab Pvt. Ltd.
| 8117816
| IS 11536 (2022) |
Processed Cereal Based Complementary Foods ? Specification ( Third Revision ) |
- |
53000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No i)(Moisture) |
- |
350 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No ii)(Total Protein) |
- |
700 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No iii)(Total Fat) |
- |
600 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No iV)(Total Carbohydrates) |
- |
500 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No v)(Total Ash) |
- |
450 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No vi)(Acid insoluble ash in dilute hydrochloric acid) |
- |
500 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No vii)(Iron) |
- |
500 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No viii)(Vitamin A (as Retinol equivalent RE)) |
- |
2500 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No ix)(Vitamin C) |
- |
1500 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No x)(Vitamon D) |
- |
2500 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xi)(Crude fibre (on dry basis)) |
- |
600 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xii)(Thiamine) |
- |
1800 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xiii)(Riboflavin) |
- |
1800 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xiv)(Niacin equivalent) |
- |
1800 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xv)(Pantothenic acid) |
- |
1500 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xvi)(Pyridoxine) |
- |
1800 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xvii)(Biotine) |
- |
1800 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xviii)(Dietary folate equivalent (DFE)2)) |
- |
2500 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xix)(Vitamin B12) |
- |
1800 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xx)(Zinc) |
- |
500 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xxi)(Choline) |
- |
2200 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xxii)(Inositol) |
- |
3000 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xxiii)(Selenium) |
- |
500 |
|
- |
| Clause 4.13,Table 3 ,Sl No i)(Lead) |
- |
500 |
|
- |
| Clause 4.13,Table 3 ,Sl No ii)(Copper) |
- |
500 |
|
- |
| 4.13, Table 3 (iii)(Arsenic - IS 11124 or AOAC 2015.01) |
- |
500 |
|
- |
| Clause 4.13,Table 3 ,Sl No iv)(Tin) |
- |
500 |
|
- |
| Clause 4.13,Table 3 ,Sl No v)(Cadmium) |
- |
500 |
|
- |
| Clause 4.13,Table 3 ,Sl No vi)(Melamine) |
- |
2000 |
|
- |
| Clause 4.13,Table 3 ,Sl No vii)(Total aflatoxin) |
- |
2500 |
|
- |
| Clause 4.13,Table 3 ,Sl No viii)(Aflatoxin B1) |
- |
1500 |
|
- |
| Clause 4.10,Table 2 ,Sl No i)(Aerobic plate count) |
- |
500 |
|
- |
| Clause 4.10,Table 2 ,Sl No ii)(Coliform Count) |
- |
500 |
|
- |
| Clause 4.10,Table 2 ,Sl No iii)(Staphylococcus aureus (Coagulase positive)) |
- |
700 |
|
- |
| "4.10 Table 2 (iv) "(Yeast & mould count-IS 5403) |
- |
500 |
|
- |
| Clause 4.10,Table 2 ,Sl No v)(Salmonella sp.) |
- |
700 |
|
- |
| Clause 4.10,Table 2 ,Sl No vi)(Listeria moncytogenes) |
- |
700 |
|
- |
| Clause 4.10,Table 2 ,Sl No vii)(Bacillus cereus) |
- |
500 |
|
- |
| Clause 4.10,Table 2 ,Sl No viii)(Sulphite reducing clostridia) |
- |
700 |
|
- |
| "4.10 Table 2 (ix)"(Escherichia coli-IS 5887 (Part 1)) |
- |
600 |
|
- |
| 4.15.1.5(Vibrio cholerae & Vibrio parahaemolyticus) |
- |
1200 |
|
- |
| 5.1.1(Bisphenol A (BPA)) |
- |
5500 |
|
- |
| 4.1(Description- IS 11536) |
- |
100 |
|
- |
| 4.6(Sodium-IS 12760) |
- |
600 |
|
- |
|
19 Feb, 2027 |
- REVISED VERSION OF IS 11536:2022 INCLUDED W.E.F. 25-05-2023 |
| 9457 |
Avon Food Lab Pvt. Ltd.
| 8117816
| IS 16232 (2014) |
Iron fortified iodized salt (Double Fortified Salt) - Food grade - Specification |
- |
7500 View breakup
Rs.7500/- for iron fortified iodized salt (double fortified salt)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Description - Iron fortified iodized salt (Double fortified salt) shall
be crushed crystalline solid; white or pale pink or light
grey in colour, free from contamination with clay and
other extraneous adulterants and impurities) |
- |
0 |
|
NA |
| 3.2(Salt used for manufacture of double fortified salt - Moisture- Annex A of IS 7224) |
- |
0 |
|
NA |
| 3.2(Salt used for manufacture of double fortified salt - sodium chloride content on dry weight basis- A-5 of IS 253) |
- |
0 |
|
NA |
| 3.3(material shall pass through 4.00 mm IS sieve) |
- |
300 |
|
NA |
| 3.4 - Table 1 - i(Moisture - Annex A of IS 7224) |
- |
300 |
|
NA |
| 3.4 - Table 1 - ii(Water insoluble matter, on dry basis - A-4 of IS 253
) |
- |
500 |
|
NA |
| 3.4 - Table 1 - iii(Chloride content (as NaCl), on dry basis - A-4 of IS 253) |
- |
600 |
|
NA |
| 3.4 - Table 1 - iv(Matter insoluble in dilute HCl, on dry basis - Annex G) |
- |
600 |
|
NA |
| 3.4 - Table 1 - v(Matter soluble in water other than sodium chloride, on dry basis - A-6 of IS 253) |
- |
500 |
|
NA |
| 3.4 - Table 1 - vi(Iron content (as Fe) - Annex A) |
- |
500 |
|
NA |
| 3.4 - Table 1 - vii- a(Iodine content, Manufacturer’s level - Annex B) |
- |
900 |
|
NA |
| 3.4 - Table 1 - vii- b(Iodine content, Distribution channel including retail level - Annex B) |
- |
900 |
|
NA |
| 3.4 - Table 1 - viii - a(pH of 5 percent aqueous solution : For iron fortification through
encapsulated ferrous fumarate - Annex C) |
- |
300 |
|
NA |
| 3.4 - Table 1 - viii - b(pH of 5 percent aqueous solution : For other forms of iron fortification - Annex C) |
- |
300 |
|
NA |
| 3.4 - Table 1 - ix(Sulphate (as SO4) - A-8 of IS 253) |
- |
500 |
|
NA |
| 3.4 - Table 1 - x(Magnesium (as Mg), water soluble - A-7 of IS 253) |
- |
500 |
|
NA |
| 3.4 - Table 1 - xi - a(Phosphorous (as P2O5) - For iron fortification through
encapsulated ferrous fumarate - Annex D) |
- |
1000 |
|
NA |
| 3.4 - Table 1 - xi - b(Phosphorous (as P2O5) - For other forms of iron fortification - Annex D) |
- |
1000 |
|
NA |
| 3.4 - Table 1 - xii(Sodium hexa meta phosphate, on dry basis - Annex E) |
- |
1000 |
|
NA |
|
19 Feb, 2027 |
- - |
| 9458 |
Avon Food Lab Pvt. Ltd.
| 8117816
| IS 12981 (1991) |
Common salt - Iron fortified - Specification |
Nil |
6700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| CL 3.1(Description ) |
- |
0 |
|
NA |
| CL 3.2(Moisture) |
- |
300 |
|
NA |
| CL 3.3, Annex A of IS 253 : 1985(Particle Size) |
- |
300 |
|
NA |
| Table 1 (i), Annex A, Annex IS 253 :
1985
A-4(Water insoluble matter) |
- |
1000 |
|
NA |
| Table 1 (ii), IS 253 :
1985
A-5(Chloride content ( as NaCl )) |
- |
1000 |
|
NA |
| Table 1 (iii), IS 253 :
1985
A-6(Matter insoluble in dilute hydrochloric acid.) |
- |
600 |
|
NA |
| Table 1 (iv), IS 253 :
1985
A-7(Matter soluble in water, other than sodium chloride) |
- |
600 |
|
NA |
| Table 1 (v), IS 253 :
1985
A-8(Magnesium ( as Mg ), water soluble) |
- |
600 |
|
NA |
| Table 1 (vi), IS 253 :
1985
A-9(Sulphates (as SO4)) |
- |
600 |
|
NA |
| Table 1 (vii), Annex A-2(Iron ( as Fe )) |
- |
600 |
|
NA |
| Table 1 (vii), Annex A-3(pH of 5 percent aqueous solution) |
- |
300 |
|
NA |
| Table 1 (vii), Annex A-4(Phosphates ( as PO4 )) |
- |
800 |
|
NA |
|
19 Feb, 2027 |
- - |
| 9459 |
Avon Food Lab Pvt. Ltd.
| 8117816
| IS 12299 (1998) |
Dairy whitener - Specification (First Revision) |
Nil |
18300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Description) |
- |
0 |
|
NA |
| 5.3(Flavour and Taste) |
- |
0 |
|
NA |
| 5.5.1(Bacterial Count) |
- |
2200 |
|
NA |
| 5.5.2(Coliform Count) |
- |
2200 |
|
NA |
| 5.5.2(E Coli) |
- |
2200 |
|
NA |
| 5.5.2(Staphylococcus aureus) |
- |
2200 |
|
NA |
| 5.5.3(Salmonella) |
- |
2200 |
|
NA |
| 5.6 Table 1 i)(Moisture) |
- |
550 |
|
NA |
| 5.6 Table 1 ii)(Milk Solids (non-fat)) |
- |
1350 |
|
NA |
| 5.6 Table 1 iii)(Insolubility Index) |
- |
1500 |
|
NA |
| 5.6 Table 1 iv)(Total Ash (on dry basis)) |
- |
700 |
|
NA |
| 5.6 Table 1 v)(Milk Fat) |
- |
850 |
|
NA |
| 5.6 Table 1 vi)(Acid Insoluble ash) |
- |
850 |
|
NA |
| 5.6 Table 1 vii)(Total added sugar) |
- |
1500 |
|
NA |
|
19 Feb, 2027 |
- - |
| 9460 |
Avon Food Lab Pvt. Ltd.
| 8117816
| IS 7021 (2017) |
Protein - Rich food supplements for infants and pre - School children - Specification (First Revision) |
NA |
10500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.3.3 Table 2(Acid insoluble Ash) |
- |
450 |
|
NA |
| 4.2.4(Urease activity) |
- |
800 |
|
NA |
| 4.3.3 Table 2(Crude Fibre) |
- |
450 |
|
NA |
| 4.3.3 Table 2(Total Ash) |
- |
400 |
|
NA |
| 4.3.3 Table 2(Coliform count) |
- |
400 |
|
NA |
| 4.2.3(Gossypol (free gossypol Content ) ) |
- |
800 |
|
NA |
| 4.2.2(Aflatoxin) |
- |
1000 |
|
NA |
| 4.3.3 Table 2(Bacterial Count) |
- |
400 |
|
NA |
| 4.2.5 Table 1(Thiamine ) |
- |
600 |
|
NA |
| 4.2.5 Table 1(Riboflavin) |
- |
600 |
|
NA |
| 4.2.5 Table 1(Vitamin B12) |
- |
600 |
|
NA |
| 4.2.5 Table 1(Vitamin D) |
- |
800 |
|
NA |
| 4.2.5 Table 1(Niacin) |
- |
600 |
|
NA |
| 4.2.5 Table 1(Iron) |
- |
450 |
|
NA |
| 4.3.3 Table 2(Fat) |
- |
400 |
|
NA |
| 4.3.3 Table 2(Moisture) |
- |
300 |
|
NA |
| 4.2.1(Protein) |
- |
400 |
|
NA |
| 4.3.3 Table 2(Protein) |
- |
400 |
|
NA |
| 4.2.5 Table 1(Vitamin C) |
- |
700 |
|
NA |
| 4.2.5 Table 1(Folate) |
- |
600 |
|
NA |
| 4.2.5 Table 1(Vitamin A) |
- |
800 |
|
NA |
| 4.2.5 Table 1(Calcium ) |
- |
450 |
|
NA |
| 4.3.1(Description) |
- |
0 |
|
NA |
| 4.3.2(Flavour) |
- |
0 |
|
NA |
|
19 Feb, 2027 |
- - |
| 9461 |
Avon Food Lab Pvt. Ltd.
| 8117816
| IS 1806 (2018) |
Malted milk foods - Specification (Second Revision) |
Type I & II |
9950 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.3-Table 1- i(Moisture) |
- |
500 |
|
NA |
| 4.3-Table 1- ii(Total protein (N × 6.25) (on dry basis),) |
- |
800 |
|
NA |
| 4.3-Table 1- iii(Total fat (on dry basis)) |
- |
700 |
|
NA |
| 4.3-Table 1- iv(Total ash (on dry basis)) |
- |
500 |
|
NA |
| 4.3-Table 1- v(Acid insoluble ash (on dry basis) (in dilute HCl)) |
- |
650 |
|
NA |
| 4.3-Table 1- vi(Solubility) |
- |
500 |
|
NA |
| 4.3-Table 1- vii(Cocoa powder (on dry basis)) |
- |
600 |
|
NA |
| 4.3-Table 1- viii(Test for starch) |
- |
300 |
|
NA |
| 4.3-Table 1- ix(Bacterial count) |
- |
400 |
|
NA |
| 4.3-Table 1- x(Coliform count) |
- |
400 |
|
NA |
| 4.3-Table 1- xii(Yeast and mould count) |
- |
550 |
|
NA |
| 4.3-Table 1- xiii(Salmonella) |
- |
800 |
|
NA |
| 4.3-Table 1- xiv(Shigella) |
- |
800 |
|
NA |
| 4.3-Table 1- xv(Vibrio cholerae ) |
- |
500 |
|
NA |
| 4.3-Table 1- xv( V. parahaemolyticus) |
- |
500 |
|
NA |
| 4.3-Table 1- xvi(Faecal streptococci ) |
- |
500 |
|
NA |
| 4.3-Table 1- xvi( Staphylococcusaureas) |
- |
500 |
|
NA |
| 4.3-Table 1- xi(E. coli) |
- |
450 |
|
NA |
|
19 Feb, 2027 |
- - |
| 9462 |
Avon Food Lab Pvt. Ltd.
| 8117816
| IS 1061 (2017) |
Disinfectant fluids, phenolic type - Specification (Fifth Revision) |
All Grades |
8544 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1(Composition and Description) |
- |
0 |
|
NA |
| 4.2(Stability after Dilution) |
- |
690 |
|
NA |
| 4.3/3.2(Germicidal Value) |
- |
2400 |
|
NA |
| 4.3/3.3(Germicidal Value) |
- |
2400 |
|
NA |
| 4.4(Mercury Compounds) |
- |
750 |
|
NA |
| 4.5(Stability on Storage) |
- |
1500 |
|
NA |
| 4.6(Detection of Phenolic Compounds) |
- |
800 |
|
NA |
| 4.1.2(Composition and Description) |
- |
0 |
|
NA |
|
19 Feb, 2027 |
- - |
| 9463 |
Avon Food Lab Pvt. Ltd.
| 8117816
| IS 539 (1974) |
Specification for naphthalene (Second Revision) |
Gr.I -Rs.4000& Gr.II-s.6500 |
6500 View breakup
Rs.4000/- For Gr-I, Rs.6500/- For Gr-II
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.3 Table 1(Ash, all grades) |
- |
500 |
|
NA |
| 4.3 Table 1(Matter Insoluble in Benzene, all grades) |
- |
800 |
|
NA |
| 4.3 Table 1(Non-volatile matter, all grades) |
- |
800 |
|
NA |
| 4.3 Table 1(Moisture, all grades) |
- |
400 |
|
NA |
| 4.3 Table 1(Crystallization point, Grade 2) |
- |
500 |
|
NA |
| 4.3 Table 1(Crystallization point, Grade 1) |
- |
500 |
|
NA |
| 4.1.1(Description, Grade 1) |
- |
0 |
|
NA |
| 4.1.2(Description, Grade 2) |
- |
0 |
|
NA |
| 4.2(Test for Staining) |
- |
300 |
|
NA |
| 4.3 Table 1(Colour, grade 1) |
- |
200 |
|
NA |
| 4.3 Table 1(Colour, grade 2) |
- |
200 |
|
NA |
| 4.3 Table 1(Acid wash Test, Grade 1) |
- |
500 |
|
NA |
| 4.3 Table 1(Total Nitrogen, Grade 2) |
- |
1300 |
|
NA |
| 4.3 Table 1(Total Sulphur, Grade 2) |
- |
1200 |
|
NA |
|
19 Feb, 2027 |
- - |
| 9464 |
Avon Food Lab Pvt. Ltd.
| 8117816
| IS 253 (2014) |
Specification for common salt (Fourth Revision) |
Common salt and Dairy salt |
6690 View breakup
Rs.6690/- (for both common salt & dairy salt)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause -3 for common salt 3.1 ( 3.1.1 ) ( The material shall be crystalline solid, white or pale pink or light grey in colour.) |
- |
0 |
|
NA |
| Clause -3 for common salt 3.1 ( 3.1.2 ) Annex-2(Moisture The material shall contain not more than 6.0 percent by mass of moisture, on as received basis, when tested according to the method given in A-2) |
- |
300 |
|
NA |
| Clause-3.2 for dairy salt (3.2.1)(The material shall be crystalline white solid and free from any visible impurities.) |
- |
0 |
|
NA |
| Clause-3.2 for dairy salt (3.2.3) Annex -2(3.2.3 Moisture The material shall contain not more than 0.5 percent by mass of moisture, on as received basis, when tested according to the methods given in A-2.) |
- |
300 |
|
NA |
| Clause-3.1 for dairy salt (3.2.2)(3.2.2 Particle Size 99 percent by mass of the material shall pass completely through 850-micron IS Sieve [see IS 460 (Part I)].) |
- |
300 |
|
NA |
| Table 1 (i) Annex -4(Water insoluble matter, common) |
- |
600 |
|
NA |
| Table 1 (i) Annex -4(Water insoluble matter, Dairy) |
- |
600 |
|
NA |
| Table 1 (ii) Annex-5(Chloride content (as NaCl)common) |
- |
600 |
|
NA |
| Table 1 (ii) Annex-5(Chloride content (as NaCl), Dairy) |
- |
600 |
|
NA |
| Table 1 (iii) Annex-6( Matter soluble in water, other than sodium chloride, common) |
- |
600 |
|
NA |
| Table 1 (iii) Annex-6( Matter soluble in water, other than sodium chloride, Dairy) |
- |
600 |
|
NA |
| Table 1 (iv)(Calcium (as Ca), water soluble, percent by mass, common) |
- |
500 |
|
NA |
| Table 1 (iv) Annex-7(Calcium (as Ca), water soluble, percent by mass, Dairy) |
- |
500 |
|
NA |
| Table 1 (v)(Magnesium (as Mg), water soluble, percent by mass, common ) |
- |
500 |
|
NA |
| Table 1 (v) Annex-7(Magnesium (as Mg), water soluble, percent by mass, Dairy ) |
- |
500 |
|
NA |
| Table 1 (vi)(Sulphate as SO2 percent by mass, common) |
- |
500 |
|
NA |
| Table 1 (vi) Annex-8(sulphate as SO2 percent by mass, Dairy) |
- |
500 |
|
NA |
| Table 1 (vii) Annex-9(Alkalinity (as Na2CO3), common) |
- |
500 |
|
NA |
| Table 1 (vii) Annex-11(Alkalinity (as Na2CO3), Dairy) |
- |
500 |
|
NA |
| Table 1 (viii)(Lead (as Pb), common) |
- |
400 |
|
NA |
| Table 1 (viii)(Lead (as Pb),Dairy ) |
- |
400 |
|
NA |
| Table 1 (ix)(Iron (as Fe), common) |
- |
400 |
|
NA |
| Table 1 (ix)(Iron (as Fe), Dairy) |
- |
400 |
|
NA |
| Table 1 (x) Annex-11(x) Arsenic (as As), common) |
- |
400 |
|
NA |
| Table 1 (x) Annex-11(x) Arsenic (as As),Dairy) |
- |
400 |
|
NA |
| Table 1 (xi) Annex-12(Copper (as Cu), common) |
- |
400 |
|
NA |
| Table 1 (xi) Annex-12(Copper (as Cu), Dairy ) |
- |
400 |
|
NA |
|
19 Feb, 2027 |
- 0.0 |
| 9465 |
Gujarat Testlab Private Limited, Ahmedabad
| 7137016
| IS 13334 : Part 2 (2014) |
Skimmed milk powder - Specification: Part 2 extra grade (First Revision) |
500 GM / 1 KG |
4500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table 1 (i)(Moisture (IS 116231or 16072)) |
- |
200 |
|
- |
| Table 1 (ii)(Milk protein in milk solids not fat (IS 72192)) |
- |
250 |
|
- |
| Table 1 (iii)(Milk fat (IS 117213) or Annex B) |
- |
200 |
|
- |
| Table 1 (iv)(Insolubility index (IS 12759)) |
- |
300 |
|
- |
| Table 1 (v)(Total ash (on dry basis), Annex B of IS 14433) |
- |
250 |
|
- |
| Table 1 (vi)(Titratable acidity (IS 11766)) |
- |
250 |
|
- |
| Table 1 (vii)(Lactate content (IS 11202)) |
- |
500 |
|
- |
| Table 1 (viii)(Scorched particles (equivalent to Disc B) (IS 13500)) |
- |
500 |
|
- |
| Table 1 (ix)(Bacterial count (IS 5402)) |
- |
250 |
|
- |
| Table 1 (x)(Coliform count (IS 5401 - Part 1)) |
- |
250 |
|
- |
| Table 1 (xi)(Escherichia coli (IS 5887 - Part 1)) |
- |
250 |
|
- |
| Table 1 (xii)(Coagulase positive Staphylococcus aureus (IS 5887 - Part 2)) |
- |
250 |
|
- |
| Table 1 (xiii)(Salmonella (IS 5887 - Part 3)) |
- |
250 |
|
- |
| Table 1 (xiv)(a)(Spore Count: a)Aerobic (Bacillus cereus) Type m (IS 5887 - Part 6)) |
- |
250 |
|
- |
| Table 1 (xiv)(b)(Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type m (ISO 15213 : 2003)) |
- |
250 |
|
- |
| Table 1 (xv)(Listeria monocytogenes (IS 14988 - Part 2 : 2001)) |
- |
300 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f 20.05.2024 |
| 9466 |
Gujarat Testlab Private Limited, Ahmedabad
| 7137016
| IS 13334 : Part 1 (2014) |
Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) |
500 gm / 1 Kg |
4350 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.6(Listeria monocytogenes) |
- |
300 |
|
- |
| 5.6(Spore count, Anaerobic (Sulfite reducing Clostridia)) |
- |
250 |
|
- |
| 5.6(Spore count, Aerobic (Bacillus cereus)) |
- |
250 |
|
- |
| 5.6(Salmonella) |
- |
250 |
|
- |
| 5.6(Coagulase positive Staphylococcus aureus) |
- |
250 |
|
- |
| 5.6(Escherichia coli) |
- |
250 |
|
- |
| 5.6(Coliform count ) |
- |
250 |
|
- |
| 5.6(Bacterial count) |
- |
250 |
|
- |
| 5.6(Scorched particles) |
- |
500 |
|
- |
| 5.6(Titratable acidity (lactic acid)) |
- |
250 |
|
- |
| 5.6(Total ash (on dry basis)) |
- |
250 |
|
- |
| 5.6(Insolubility index) |
- |
300 |
|
- |
| 5.6(Milk fat) |
- |
200 |
|
- |
| 5.6(Milk protein in milk solids not fat) |
- |
250 |
|
- |
| 5.6(Moisture) |
- |
200 |
|
- |
| 5.2(Absence of extraneous matter, added colour and added flavour) |
- |
250 |
|
- |
| 4(Description) |
- |
100 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f 20.05.2024
Exclusion: Cl.5.2 (Calcium chloride, citric acid and sodium citrate) |
| 9467 |
Gujarat Testlab Private Limited, Ahmedabad
| 7137016
| IS 16232 (2014) |
Iron fortified iodized salt (Double Fortified Salt) - Food grade - Specification |
1 Kg / 500 gm |
2500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Description - Iron fortified iodized salt (Double fortified salt) shall
be crushed crystalline solid; white or pale pink or light
grey in colour, free from contamination with clay and
other extraneous adulterants and impurities) |
- |
50 |
|
- |
| 3.3(material shall pass through 4.00 mm IS sieve) |
- |
100 |
|
- |
| 3.4 - Table 1 - i(Moisture - Annex A of IS 7224) |
- |
100 |
|
- |
| 3.4 - Table 1 - ii(Water insoluble matter, on dry basis - A-4 of IS 253
) |
- |
100 |
|
- |
| 3.4 - Table 1 - iii(Chloride content (as NaCl), on dry basis - A-4 of IS 253) |
- |
150 |
|
- |
| 3.4 - Table 1 - iv(Matter insoluble in dilute HCl, on dry basis - Annex G) |
- |
100 |
|
- |
| 3.4 - Table 1 - v(Matter soluble in water other than sodium chloride, on dry basis - A-6 of IS 253) |
- |
100 |
|
- |
| 3.4 - Table 1 - vi(Iron content (as Fe) - Annex A) |
- |
500 |
|
- |
| 3.4 - Table 1 - vii- a(Iodine content, Manufacturer’s level - Annex B) |
- |
200 |
|
- |
| 3.4 - Table 1 - viii - a(pH of 5 percent aqueous solution : For iron fortification through
encapsulated ferrous fumarate - Annex C) |
- |
100 |
|
- |
| 3.4 - Table 1 - ix(Sulphate (as SO4) - A-8 of IS 253) |
- |
200 |
|
- |
| 3.4 - Table 1 - x(Magnesium (as Mg), water soluble - A-7 of IS 253) |
- |
100 |
|
- |
| 3.4 - Table 1 - xi - a(Phosphorous (as P2O5) - For iron fortification through
encapsulated ferrous fumarate - Annex D) |
- |
350 |
|
- |
| 3.4 - Table 1 - xii(Sodium hexa meta phosphate, on dry basis - Annex E) |
- |
350 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f 20.05.2024 |
| 9468 |
Bharat Test House Pvt Ltd 781 Sonipat Haryana
| 9137826
| IS 302 : Part 2 : SEC 31 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 31 range hoods |
Range hoods |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
| Clause No - 5.18(linear and angular dimension) |
- |
0 |
|
- |
| Clause No - 6.2(harmfull ingress of water) |
- |
50 |
|
5% discount for BIS |
| Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
500 |
|
5% discount for BIS |
| Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
500 |
|
5% discount for BIS |
| Clause No - 8.2(Addition) |
- |
500 |
|
5% discount for BIS |
| Clause No - 10.1, Table No. -1(power input deviation) |
- |
1000 |
|
5% discount for BIS |
| Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
2000 |
|
5% discount for BIS |
| Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
2000 |
|
5% discount for BIS |
| Clause No - 14(Impulse test voltage) |
- |
2000 |
|
5% discount for BIS |
| Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
5000 |
|
5% discount for BIS |
| Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
2800 |
|
5% discount for BIS |
| Clause No -21.1(Mechanical strength) |
- |
1000 |
|
5% discount for BIS |
| Clause No -22.1(construction) |
- |
2500 |
|
5% discount for BIS |
| Clause No -22.11(push force applied) |
- |
2500 |
|
5% discount for BIS |
| Clause No -25.8, Table no -11(conductor resistance) |
- |
1500 |
|
5% discount for BIS |
| Clause No -25.5(dimension for pins) |
- |
1500 |
|
5% discount for BIS |
| Clause No -27.6(for circuit board) |
- |
1000 |
|
5% discount for BIS |
| Clause No -29.2(comparative tracking index) |
- |
1000 |
|
5% discount for BIS |
| Clause No -29.3.3(dry heat test) |
- |
1000 |
|
5% discount for BIS |
| Clause No -30.2.1(glow wire test) |
- |
2000 |
|
5% discount for BIS |
| Clause No -30.101("incorporate combustible
material") |
- |
2000 |
|
5% discount for BIS |
|
31 Dec, 2026 |
- Exclusion: Clause No -19.11.4.1 (electrostatic discharge)
Clause No -19.11.4.2 (radiated field)
Clause No -19.11.4.3 (fast transient)
Clause No -19.11.4.4 (Voltage dips and interruption)
Clause No -24.1.2 (safety isolating transformer)
Clause No -24.1.3 (for switches)
Clause No -24.1.4 (for automatic control)
Clause No -24.1.5 (for innterconnection couplers)
Clause No -24.4 (plug and socket) |
| 9469 |
AADCO TESTING & RESEARCH LABORATORY PVT LTD (F28), GHAZIABAD
| 8141606
| IS 9537 : Part 3 (1983) |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
All Size & All Classification |
9500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Marking) |
- |
150 |
|
- |
| 6.2(Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
250 |
|
- |
| 6.3(Standard Mark on Conduit) |
- |
150 |
|
- |
| 7.1.1(Maximum and minimum outside diameter of socket) |
- |
250 |
|
- |
| 7.1.1 Table-2(Length of Socket end) |
- |
150 |
|
- |
| 7.1.2(Maximum and minimum outside diameter of conduit) |
- |
250 |
|
- |
| 7.2(Minimum inside diameter of conduit) |
- |
250 |
|
- |
| 7.3(Length of conduit) |
- |
150 |
|
- |
| 7.4(Unifomity of The wall Thickness) |
- |
250 |
|
- |
| 8.1(Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
150 |
|
- |
| 9.2(Bending Test i) At Room Temp ii) At Low Temp (-5 ±2°C)) |
- |
750 |
|
- |
| 9.3(Compression Test as per caluse 9.3 of IS: 9537 (Part 1)-1980) |
- |
750 |
|
- |
| 9.4(Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
1200 |
|
- |
| 9.5(Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
750 |
|
- |
| 10(Resistance to Heat -Ball presure test) |
- |
500 |
|
- |
| 11(Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
750 |
|
- |
| 12(Electrical Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
1250 |
|
- |
| 12(Electrical Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
1250 |
|
- |
| 13(Tests for external influence as per clause 13 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
| 13(Tests for external influence as per clause 13 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
| 12(3 Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
1250 |
|
- |
| 12(3 Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
1250 |
|
- |
| 11.0(Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
750 |
|
- |
| 10.0(Resistance to Heat -Ball presure test) |
- |
500 |
|
- |
| 9.5 Fig.5(Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
750 |
|
- |
| 9.4(Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
1200 |
|
- |
| 9.3(Compression Test (after removal of force) as per caluse 9.3.3 of IS: 9537 (Part 1)-1980) |
- |
750 |
|
- |
| 9.3(Compression Test at Full force applied (On load)) |
- |
750 |
|
- |
| 9.2(Bending Test At Low Temp (-5 ±2°C)) |
- |
750 |
|
- |
| 9.2(Bending Test At Room Temp) |
- |
750 |
|
- |
| 8.1(Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
150 |
|
- |
| 7.4(Unifomity of The wall Thickness) |
- |
250 |
|
- |
| 7.3(Length of conduit) |
- |
150 |
|
- |
| 7.2 Fig.3(Minimum inside diameter of conduit) |
- |
250 |
|
- |
| 7.1.2 Fig.2(Minimum outside diameter of conduit) |
- |
250 |
|
- |
| 7.1.2 Fig.1(Maximum outside diameter of conduit) |
- |
250 |
|
- |
| 7.1.1 Table-2(Length of Socket end) |
- |
150 |
|
- |
| 7.1.1 Fig.8(Maximum inside diameter of socket) |
- |
250 |
|
- |
| 7.1.1 Fig.7(Maximum outside diameter of socket) |
- |
250 |
|
- |
| 6.3(Standard Mark on Conduit) |
- |
150 |
|
- |
| 6.2(Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
250 |
|
- |
| 6.1 - d(Marking) |
- |
150 |
|
- |
| 6.1 - c(Marking) |
- |
150 |
|
- |
| 6.1 - b(Marking) |
- |
150 |
|
- |
| 6.1 - a(Marking) |
- |
150 |
|
Clauses are repeated again and again |
|
26 Jul, 2027 |
- - |
| 9470 |
TATA STEEL, Jamshedpur
| 5182706
| IS 7283 (1992) |
Hot - Rolled bars for the production of bright bars and machined parts for engineering applications specification (First Revision) |
- |
6740 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 6(Workmanship) |
- |
0 |
|
- |
| Cl 7(Diameter & Out Of Round) |
- |
0 |
|
- |
| Cl 8(Decarburization) |
- |
2000 |
|
- |
| Cl 9(Inclusion) |
- |
2000 |
|
- |
| Cl 10(Hardenability) |
- |
2000 |
|
- |
| Cl 11(Size) |
- |
0 |
|
- |
| Cl 6(Workmanship) |
- |
0 |
|
- |
| Cl 7(Diameter & Out Of Round) |
- |
0 |
|
- |
| Cl 8(Decarburization) |
- |
2000 |
|
- |
| Cl 9(Inclusion) |
- |
2000 |
|
- |
| Cl 10(Hardenability) |
- |
2000 |
|
- |
| Cl 11(Size) |
- |
1740 |
|
- |
| Cl 6(Workmanship) |
- |
0 |
|
- |
| Cl 7(Diameter & Out Of Round) |
- |
0 |
|
- |
| Cl 8(Decarburization) |
- |
2000 |
|
- |
| Cl 9(Inclusion) |
- |
2000 |
|
- |
| Cl 10(Hardenability) |
- |
2000 |
|
- |
| Cl 11(Size) |
- |
0 |
|
- |
| Cl 6(Workmanship) |
- |
0 |
|
- |
| Cl 7(Diameter & Out Of Round) |
- |
0 |
|
- |
| Cl 8(Decarburization) |
- |
2000 |
|
- |
| Cl 9(Inclusion) |
- |
2000 |
|
- |
| Cl 10(Hardenability) |
- |
2000 |
|
- |
| Cl 11(Size) |
- |
0 |
|
- |
| Cl 6(Workmanship) |
- |
0 |
|
- |
| Cl 7(Diameter & Out Of Round) |
- |
0 |
|
- |
| Cl 8(Decarburization) |
- |
2000 |
|
- |
| Cl 9(Inclusion) |
- |
2000 |
|
- |
| Cl 10(Hardenability) |
- |
2000 |
|
- |
| Cl 11(Size) |
- |
0 |
|
- |
| Cl 6(Workmanship) |
- |
0 |
|
- |
| Cl 7(Diameter & Out Of Round) |
- |
0 |
|
- |
| Cl 8(Decarburization) |
- |
2000 |
|
- |
| Cl 9(Inclusion) |
- |
2000 |
|
- |
| Cl 10(Hardenability) |
- |
2000 |
|
- |
| Cl 11(Size) |
- |
0 |
|
- |
| Cl 5(Material Test) |
- |
0 |
|
- |
| 5, 5.1, 5.2(Chemical Composition - Carbon) |
- |
4000 |
|
- |
| 5, 5.1, 5.2(Chemical Composition - Sulphur) |
- |
4000 |
|
- |
| 5, 5.1, 5.2(Chemical Composition - Phosphorus) |
- |
4000 |
|
- |
| 5, 5.1, 5.2(Chemical Composition - Manganese) |
- |
4000 |
|
- |
| 5, 5.1, 5.2(Chemical Composition - Silicon) |
- |
4000 |
|
- |
| 5, 5.1, 5.2(Chemical Composition - Nickel) |
- |
4000 |
|
- |
| 5, 5.1, 5.2(Copper) |
- |
4000 |
|
- |
| 5, 5.1, 5.2(Chromium) |
- |
4000 |
|
- |
| 5, 5.1, 5.2(Chemical Composition - Lead) |
- |
4000 |
|
- |
| 5, 5.1, 5.2(Chemical Composition - Nitrogen) |
- |
4000 |
|
- |
| Cl 11(Size) |
- |
0 |
|
- |
| Cl 10(Hardenability) |
- |
2000 |
|
- |
| Cl 9(Inclusion) |
- |
2000 |
|
- |
| Cl 8(Decarburization) |
- |
2000 |
|
- |
| Cl 7(Diameter & Out Of Round) |
- |
0 |
|
- |
| Cl 6(Workmanship) |
- |
0 |
|
- |
| 11(Grain Size) |
- |
2000 |
|
- |
| Cl 6(Workmanship) |
- |
0 |
|
- |
| 7(Diameter & Out Of Round) |
- |
0 |
|
- |
| Cl 8(Decarburization) |
- |
2000 |
|
- |
| Cl 9(Inclusion) |
- |
2000 |
|
- |
| Cl 10(Hardenability) |
- |
2000 |
|
- |
| Cl 11(Size) |
- |
0 |
|
- |
| 14(Marking) |
- |
0 |
|
- |
| 14(Marking) |
- |
0 |
|
- |
| 14(Marking) |
- |
0 |
|
- |
| 14(Marking) |
- |
0 |
|
- |
| 5(Material - IS 7283) |
- |
0 |
|
- |
| 7.3(Dimensional Cutting -IS 7283) |
- |
0 |
|
- |
|
25 Nov, 2027 |
- - |
| 9471 |
Bharat Test House Pvt Ltd 1474 Sonipat Haryana
| 9135626
| IS 11328 (2022) |
Self-contained Automatic Ice Makers Specification (First Revision) |
Self-contained Automatic Ice Makers |
24000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.1(Construction) |
- |
250 |
|
5% discount for BIS |
| Cl-5.2(Water Condensation) |
- |
250 |
|
5% discount for BIS |
| Cl-5.3(Safety Features in Design) |
- |
250 |
|
5% discount for BIS |
| Cl-5.4(Control of Operation) |
- |
250 |
|
5% discount for BIS |
| Cl-5.5(Location of the Components) |
- |
250 |
|
5% discount for BIS |
| Cl-6.1(Motors) |
- |
250 |
|
5% discount for BIS |
| Cl-6.3(Motor Starters, Relays, Thermostat, Controls, etc) |
- |
250 |
|
5% discount for BIS |
| Cl-6.4(Wiring) |
- |
250 |
|
5% discount for BIS |
| Cl-6.5(Electrical Accessories) |
- |
250 |
|
5% discount for BIS |
| Cl-6.6(Earth Connection) |
- |
250 |
|
5% discount for BIS |
| Cl-7.1(General Requirements for Tests) |
- |
250 |
|
5% discount for BIS |
| Cl-7.2(Ice Weighing Instruments) |
- |
250 |
|
5% discount for BIS |
| Cl-7.3(Type Tests) |
- |
16000 |
|
5% discount for BIS |
| Cl-7.4(Routine Tests) |
- |
7000 |
|
5% discount for BIS |
| Cl-7.5(Acceptance Tests) |
- |
16000 |
|
5% discount for BIS |
| Cl-7.6(Test Procedure) |
- |
16000 |
|
5% discount for BIS |
| Cl-8(Marking) |
- |
250 |
|
5% discount for BIS |
|
19 Mar, 2029 |
- - |
| 9472 |
National Test House (WR) - NTH, Mumbai
| 7107604
| IS/IEC 60335 : Part 2 : Sec 40 (2018) |
Household and similar electrical appliances safety : Particular requirements for electrical heat pumps air-conditioners and dehumidifiers Adoption of IEC 60335-2-40 |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General requirement) |
- |
500 |
|
- |
| 5(General conditions for the tests) |
- |
500 |
|
- |
| 6(Classification) |
- |
500 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
| 8(Protection against access to live parts) |
- |
1000 |
|
- |
| 10(Power input and current) |
- |
1500 |
|
- |
| 11(Heating) |
- |
2500 |
|
- |
| 14(Transient overvoltages) |
- |
1000 |
|
- |
| 15(Moisture resistance) |
- |
2000 |
|
- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
1000 |
|
- |
| 19.11.4.7(Mains signals) |
- |
1000 |
|
- |
| 20(Stability and mechanical hazards) |
- |
1000 |
|
- |
| 21(Mechanical strength) |
- |
1000 |
|
- |
| 22(Construction) |
- |
500 |
|
- |
| 23(Internal wiring) |
- |
500 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
| 26(Terminals for external conductors) |
- |
1000 |
|
- |
| 31(Resistance to rusting) |
- |
1500 |
|
- |
| 30(Resistance to heat and fire) |
- |
1000 |
|
- |
| 29(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
- |
| 28(Screws and connections) |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
1500 |
|
- |
| 4(General requirement) |
- |
500 |
|
- |
| 5(General conditions for the tests) |
- |
500 |
|
- |
| 6(Classification) |
- |
500 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
| 8(Protection against access to live parts) |
- |
500 |
|
- |
| 10(Power input and current) |
- |
500 |
|
- |
| 11(Heating) |
- |
1000 |
|
- |
| 14(Transient overvoltages) |
- |
500 |
|
- |
| 15(Moisture resistance) |
- |
1000 |
|
- |
| 16(Leakage current and electric strength) |
- |
500 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
500 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
500 |
|
- |
| 19.11.4.7(Mains signals) |
- |
500 |
|
- |
| 20(Stability and mechanical hazards) |
- |
500 |
|
- |
| 21(Mechanical strength) |
- |
500 |
|
- |
| 22(Construction) |
- |
500 |
|
- |
| 23(Internal wiring) |
- |
500 |
|
- |
| 24(Components) |
- |
500 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 26(Terminals for external conductors) |
- |
500 |
|
- |
| 31(Resistance to rusting) |
- |
500 |
|
- |
| 30(Resistance to heat and fire) |
- |
1000 |
|
- |
| 29(Clearances, creepage distances and solid insulation) |
- |
500 |
|
- |
| 28(Screws and connections) |
- |
500 |
|
- |
| 27(Provision for earthing) |
- |
500 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
500 |
|
- |
| 19.11.4.4(Voltage dips and interruptions) |
- |
500 |
|
- |
| 19.11.4.6(Class 3 voltage dips and interruptions) |
- |
500 |
|
- |
|
24 Jul, 2025 |
- Included w.e.f. 31.07.2024
Exclusion: Cl. 12 (Void), Cl. 19.11.4.2 (Radiated fields), Cl. 19.11.4.3 (Fast transient bursts), Cl. 32 (Radiation, toxicity and similar hazards), Cl. 19.11.4.2 (Radiated fields), Cl. 19.11.4.3 (Fast transient bursts), Cl. 32 (Radiation, toxicity and similar hazards), Cl. 19.11.4.5 (Injected currents) |
| 9473 |
National Test House (WR) - NTH, Mumbai
| 7107604
| IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
500 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
| 8(Protection against live parts) |
- |
500 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
500 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
1500 |
|
- |
| 11(HEATING) |
- |
1500 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1000 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
1000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
1500 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1000 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1000 |
|
- |
| 18(ENDURANCE) |
- |
2500 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
1500 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
1000 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
| 22(CONSTRUCTION) |
- |
500 |
|
- |
| 23(INTERNAL WIRING) |
- |
500 |
|
- |
| 24(COMPONENTS) |
- |
1000 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
1000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
500 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
500 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
500 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
1000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
500 |
|
- |
| 22.16(Automatic cord reel) |
- |
500 |
|
- |
| 22.47(Water pressure inlet) |
- |
1000 |
|
- |
| 22.106(Interlocks) |
- |
500 |
|
- |
| 22.3(Flexing test) |
- |
1000 |
|
- |
| 24(Components) |
- |
500 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
1000 |
|
- |
| 4(General requirements) |
- |
500 |
|
- |
| 5(General Conditions of tests) |
- |
500 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
500 |
|
- |
| 19.11.4.7(Harmonics) |
- |
1000 |
|
- |
|
24 Jul, 2025 |
- Included w.e.f. 31.07.2024
Exclusion: Cl. 19.11.4.2 (Radiated fields), Cl. 19.11.4.3 (Fast transient bursts), Cl. 19.11.4.4 (Surge immunity test), Cl. 32 (RADIATION, TOXICITY AND SIMILAR HAZARDS), Cl. 19.11.4.5 (Injected currents) |
| 9474 |
Alpha Test House Services LLP (160), Sahibzada Ajit Singh Nagar
| 9138706
| IS 14756 (2022) |
Draft Indian Standard STAINLESS STEEL COOKWARE SPECIFICATION Second Revision of IS 14756 |
STAINLESS STEEL COOKWARE. |
16400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Material) |
- |
3000 |
|
- |
| 3.2(Material) |
- |
3000 |
|
- |
| 3.3(Material) |
- |
3000 |
|
- |
| 3.4(Material) |
- |
3000 |
|
- |
| 3.4(Material) |
- |
3000 |
|
- |
| 3.5(Material) |
- |
3000 |
|
- |
| 3.5(Material) |
- |
3000 |
|
- |
| 3.5(Material) |
- |
3000 |
|
- |
| 3.5(Material) |
- |
3000 |
|
- |
| 4.1 (Annex A)(Shapes and Dimensions) |
- |
500 |
|
- |
| 4.2 (Table 1)(Shapes and Dimensions) |
- |
500 |
|
- |
| 4.2 (Table 1)(Shapes and Dimensions) |
- |
500 |
|
- |
| 4.2(Shapes and Dimensions) |
- |
500 |
|
- |
| 4.3(Shapes and Dimensions) |
- |
500 |
|
- |
| 4.4(Shapes and Dimensions) |
- |
500 |
|
- |
| 5.1(Workmanship and Finish) |
- |
1500 |
|
- |
| 5.1(Workmanship and Finish) |
- |
1500 |
|
- |
| 5.1(Workmanship and Finish) |
- |
1500 |
|
- |
| 5.2(Workmanship and Finish) |
- |
1500 |
|
- |
| 5.3(Workmanship and Finish) |
- |
1000 |
|
- |
| 5.3(Workmanship and Finish) |
- |
1000 |
|
- |
| 5.3(Workmanship and Finish) |
- |
1000 |
|
- |
| 5.3(Workmanship and Finish) |
- |
1000 |
|
- |
| 5.3(Workmanship and Finish) |
- |
1000 |
|
- |
| 5.3(Workmanship and Finish) |
- |
1000 |
|
- |
| 5.4(Workmanship and Finish) |
- |
1000 |
|
- |
| 5.5(Workmanship and Finish) |
- |
500 |
|
- |
| 5.6(Workmanship and Finish) |
- |
200 |
|
- |
| 6.1(Staining Test) |
- |
500 |
|
- |
| 6.1(Staining Test) |
- |
500 |
|
- |
| 6.2(Mechanical Shock Test (For Cladded Utensils only)) |
- |
1000 |
|
- |
| 6.3(Thermal Shock Test (For Cladded Utensils only)) |
- |
500 |
|
- |
| 6.4(Dry Heat Test (For Cladded Utensils only)) |
- |
500 |
|
- |
| 6.5(Coating Thickness Test (For Copper Deposit)) |
- |
1000 |
|
- |
| 6.6(3 Ply) |
- |
300 |
|
- |
| 6.7.1(Nominal Capacity Test) |
- |
300 |
|
- |
| 6.7.2(Nominal Capacity Test- Diameter) |
- |
300 |
|
- |
| 6.8.1(Tests on Tempered Glass Lid) |
- |
200 |
|
- |
| 6.8.1(Tests on Tempered Glass Lid) |
- |
200 |
|
- |
| 6.8.2(Tests on Tempered Glass Lid (Ball drop test)) |
- |
200 |
|
- |
| 6.8.3(Tests on Tempered Glass Lid (thermal shock test)) |
- |
200 |
|
- |
| 6.8.4.1(Tests on Tempered Glass Lid (Free Fall Test with rim facing down)) |
- |
200 |
|
- |
| 6.8.4.2(Tests on Tempered Glass Lid (Free Fall Test without rim facing down)) |
- |
200 |
|
- |
| As per Clause 3(Carbon) |
- |
200 |
|
- |
| As per Clause 3(Silicon) |
- |
200 |
|
- |
| As per Clause 3(Manganese) |
- |
200 |
|
- |
| As per Clause 3(Nickel) |
- |
200 |
|
- |
| As per Clause 3(Chromium) |
- |
200 |
|
- |
| As per Clause 3(Sulphur) |
- |
200 |
|
- |
| As per Clause 3(phosphorus) |
- |
200 |
|
- |
| As per Clause 3(Nitrogen) |
- |
200 |
|
- |
| As per Clause 3(Titanium) |
- |
200 |
|
- |
| As per Clause 3(Aluminium) |
- |
200 |
|
- |
| As per Clause 3(Copper) |
- |
200 |
|
- |
| As per Clause 3(Magnesium) |
- |
200 |
|
- |
| As per Clause 3(Iron) |
- |
200 |
|
- |
| As per Clause 3(Zinc) |
- |
200 |
|
- |
| As per Clause 3(Arsenic) |
- |
200 |
|
- |
| As per Clause 3(Antimony) |
- |
200 |
|
- |
| As per Clause 3(Bismith) |
- |
200 |
|
- |
| As per Clause 3(Lead) |
- |
200 |
|
- |
| As per Clause 3(Tellurium) |
- |
200 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f. 19.04.2024. |
| 9475 |
ATCC TEST LABS LLP
| 8172626
| IS 7809 : Part 3 : Sec 1 (1986) |
Specification for pressure sensitive adhesive insulating tapes for electrical purposes: Part 3 requirements or individual materials: Sec 1 plasticized polyvinylchloride tapes with non - Thermosetting adhesive (First Revision) |
- |
14500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
1000 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
1000 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
1000 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
1000 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
1000 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
1000 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
1000 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
1000 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
1000 |
|
- |
| 2.1.1(Type and Desiganation) |
- |
1000 |
|
- |
| 2.1.2(Type and Desiganation) |
- |
1000 |
|
- |
| 3.1(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
1000 |
|
- |
| 3.2(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
1000 |
|
- |
| 3.3(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
1000 |
|
- |
| 3.4(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
1000 |
|
- |
| 4.1(Performance Requirments) |
- |
1000 |
|
- |
| 4.2(Performance Requirments) |
- |
1000 |
|
- |
| 4.3(Performance Requirments) |
- |
1000 |
|
- |
| 4.4(Performance Requirments) |
- |
1000 |
|
- |
| 4.5(Performance Requirments) |
- |
1000 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
1000 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
1000 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
1000 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
1000 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
1000 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
1000 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
1000 |
|
- |
| 4.8(Stability to accelerated ageing ) |
- |
1000 |
|
- |
| 4.9(Insulation resistance test) |
- |
1000 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
1000 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
1000 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
1000 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
1000 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
1000 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
1000 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
1000 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
1000 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
1000 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
1000 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
1000 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
1000 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
1000 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
1000 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
1000 |
|
- |
| 2.1.1(Type and Desiganation) |
- |
1000 |
|
- |
| 2.1.2(Type and Desiganation) |
- |
1000 |
|
- |
| 3.1(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
1000 |
|
- |
| 3.2(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
1000 |
|
- |
| 3.3(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
1000 |
|
- |
| 3.4(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
1000 |
|
- |
| 4.1(Performance Requirments) |
- |
1000 |
|
- |
| 4.2(Performance Requirments) |
- |
1000 |
|
- |
| 4.3(Performance Requirments) |
- |
1000 |
|
- |
| 4.4(Performance Requirments) |
- |
1000 |
|
- |
| 4.5(Performance Requirments) |
- |
1000 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
1000 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
1000 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
1000 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
1000 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
1000 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
1000 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
1000 |
|
- |
| 4.8(Stability to accelerated ageing ) |
- |
1000 |
|
- |
| 4.9(Insulation resistance test) |
- |
1000 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
1000 |
|
- |
| 3.1(Appearance) |
- |
1000 |
|
- |
| 3.1(Freedom from defects) |
- |
1000 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
1000 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
1000 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
1000 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
1000 |
|
- |
| Cl.No.4 of IS 7809 (Part 1)-1975(Appearance) |
- |
1000 |
|
- |
| Cl.No.5 of IS 7809 (Part 1)-1975(Freedom From Deffects) |
- |
1000 |
|
- |
| Cl.No.3.2(Width) |
- |
1000 |
|
- |
| Cl.No.3.3(Length) |
- |
1000 |
|
- |
| Cl.No.3.4(Thickness) |
- |
1000 |
|
- |
| Cl.No.4.1(Tensile Strength) |
- |
1000 |
|
- |
| Cl.No.4.2(Adhesion to Steel) |
- |
1000 |
|
- |
| Cl.No.4.3(Adhesion to backing) |
- |
1000 |
|
- |
| Cl.No.4.4(Electric Strength at RT) |
- |
1000 |
|
- |
| Cl.No.4.5(Electric Strength after Humid Conditioning) |
- |
1000 |
|
- |
| Cl.No.4.6(Flammability) |
- |
1000 |
|
- |
| Cl.No.4.7() |
- |
1000 |
|
- |
| Cl.No.4.8(Stability to accelerated ageing) |
- |
1000 |
|
- |
| Cl.No.4.9(Insulation Resistance) |
- |
1000 |
|
- |
| Cl.No.7 of IS 7809 (Part 1)-1975(Minimum Storage Life) |
- |
1000 |
|
- |
| Cl.No.4 of IS 7809 (Part 1)-1975(Appearance after minimum storage Life) |
- |
1000 |
|
- |
| Cl.No.5 of IS 7809 (Part 1)-1975(Freedom From Deffects after minimum storage Life) |
- |
1000 |
|
- |
| Cl.No.3.2(Width after minimum storage Life) |
- |
1000 |
|
- |
| Cl.No.3.3(Length after minimum storage Life) |
- |
1000 |
|
- |
| Cl.No.3.4(Thickness after minimum storage Life) |
- |
1000 |
|
- |
| Cl.No.4.1(Tensile Strength after minimum storage Life) |
- |
1000 |
|
- |
| Cl.No.4.2(Adhesion to Steel after minimum storage Life) |
- |
1000 |
|
- |
| Cl.No.4.3(Adhesion to backing after minimum storage Life) |
- |
1000 |
|
- |
| Cl.No.4.4(Electric Strength at RT after minimum storage Life) |
- |
1000 |
|
- |
| Cl.No.4.5(Electric Strength after Humid Conditioning after minimum storage Life) |
- |
1000 |
|
- |
| Cl.No.4.6(Flammability after minimum storage Life) |
- |
1000 |
|
- |
| Cl.No.4.7(Electrolytic Corrosion after minimum storage Life) |
- |
1000 |
|
- |
| Cl.No.4.8(Stability to accelerated ageing after minimum storage Life) |
- |
1000 |
|
- |
| Cl.No.4.9(Insulation Resistance after minimum storage Life) |
- |
1000 |
|
- |
| 3.1(Marking) |
- |
1000 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
1000 |
|
- |
|
15 Jun, 2026 |
- Included w.e.f. 19.09.2024 |
| 9476 |
ATCC TEST LABS LLP
| 8172626
| IS 15787 (2008) |
Switch - Socket - Outlets (Non - Interlock Type) |
- |
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.30 IS 15787:2008(Additional tests on pins providing with insulating sleeves) |
- |
3000 |
|
- |
| Cl.29 IS 15787:2008(Resistance to Rusting) |
- |
3000 |
|
- |
| Cl.28 IS 15787:2008(Resistance of insulating material to Abnormal Heat , To Fire & To tracking ) |
- |
3000 |
|
- |
| Cl.27 IS 15787:2008(Creepage distance, clearances & Distance through sealing compounds) |
- |
3000 |
|
- |
| Cl.26 IS 15787:2008(Screws, current carrying parts & connections) |
- |
3000 |
|
- |
| Cl.25 IS 15787:2008(Resistance to heat ) |
- |
3000 |
|
- |
| Cl.24 IS 15787:2008(Mechanical strength) |
- |
3000 |
|
- |
| Cl.23 IS 15787:2008(Flexible cables & their connections) |
- |
3000 |
|
- |
| Cl.22 IS 15787:2008(Force necessary to withdraw the plug ) |
- |
3000 |
|
- |
| Cl.21 IS 15787:2008(Normal operation ) |
- |
3000 |
|
- |
| Cl.20 IS 15787:2008(Making & Breaking ) |
- |
3000 |
|
- |
| Cl.19 IS 15787:2008(Temperature rise ) |
- |
3000 |
|
- |
| Cl.18 IS 15787:2008(Operation of Earthing Contacts) |
- |
3000 |
|
- |
| Cl.17 IS 15787:2008(Insulation resistance & electric strength ) |
- |
3000 |
|
- |
| Cl.16 IS 15787:2008(Resistance to ageing,To harmful ingress of water and To Humidity) |
- |
3000 |
|
- |
| Cl.15 IS 15787:2008(Interlocked Socket-outlet ) |
- |
3000 |
|
- |
| Cl.14 IS 15787:2008(Construction of Plugs and Portable Socket- Outlet ) |
- |
3000 |
|
- |
| Cl.13 IS 15787:2008(Construction of fixed socket outlet) |
- |
3000 |
|
- |
| Cl.12 IS 15787:2008(Terminals) |
- |
3000 |
|
- |
| Cl.11 IS 15787:2008(Provision for earthing ) |
- |
3000 |
|
- |
| Cl.10 IS 15787:2008(Protection against to electric shock ) |
- |
3000 |
|
- |
| Cl.9 IS 15787:2008(Checking of dimension) |
- |
3000 |
|
- |
| Cl.8 IS 15787:2008(Marking ) |
- |
3000 |
|
- |
| Cl.7 IS 15787:2008(Classification) |
- |
3000 |
|
- |
| Cl.6 IS 15787:2008(Ratings ) |
- |
3000 |
|
- |
|
15 Jun, 2026 |
- Included w.e.f.11.12.2024 |
| 9477 |
ATCC TEST LABS LLP
| 8172626
| IS 14772 (2020) |
Boxes and Enclosures for Electrical Accessories for Household and Similar Fixed Electrical Installations — General Requirements ( First Revision ) |
- |
27700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Nature of material) |
- |
2000 |
|
- |
| 7.2(Type of installation) |
- |
2000 |
|
- |
| 7.3(Types of inlets) |
- |
2000 |
|
- |
| 7.4(Clamping means) |
- |
2000 |
|
- |
| 7.5(Minimum temperature during installation) |
- |
2000 |
|
- |
| 7.6, 7.7, 7.8(The degree of ingress protection) |
- |
2000 |
|
- |
| 7.9(The provision for fixing accessories to the boxes ) |
- |
2000 |
|
- |
| 7.1(The method of fixing the terminals) |
- |
2000 |
|
- |
| 8.1(marking) |
- |
2000 |
|
- |
| 8.2(By Inspection and The marking is rubbed by hand 15s width a piece of
cloth soaked with water and again for 15s with a piece of cloth soaked with petroleum spirit.) |
- |
2000 |
|
- |
| 8.3(BIS Certification Marking) |
- |
2000 |
|
- |
| 9.0(Dimensions) |
- |
2000 |
|
- |
| 10.0(Protection against electric shock) |
- |
2000 |
|
- |
| 11.0(PROVISION FOR EARTHING) |
- |
2000 |
|
- |
| 12.0(Constructions) |
- |
2000 |
|
- |
| 13.0(Resistance to ingress of solid objects) |
- |
2000 |
|
- |
| 13.0(Resistance toharmful ingress of water) |
- |
2000 |
|
- |
| 13.0(Resistance to ageing) |
- |
2000 |
|
- |
| 14.0(insultation resistance) |
- |
2000 |
|
- |
| 14.0(electric strength) |
- |
2000 |
|
- |
| 15.0(Mechanical strength) |
- |
2000 |
|
- |
| 16.0(resistance to heat) |
- |
2000 |
|
- |
| 17.0(creepage distance) |
- |
2000 |
|
- |
| 17.0(clearances) |
- |
2000 |
|
- |
| 17.0(distance through seating compund) |
- |
2000 |
|
- |
| 18.0(Resistance to insulating material to abnormal heat and fire) |
- |
2000 |
|
- |
| 19.0(Resistance to tracking) |
- |
2000 |
|
- |
| 20.0(Resistance to corrosion) |
- |
2000 |
|
- |
|
15 Jun, 2026 |
- Included w.e.f.12.12.2024 |
| 9478 |
ATCC TEST LABS LLP
| 8172626
| IS 1258 (2005) |
Bayonet lamp holders (Fourth Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1(Marking ) |
- |
1000 |
|
- |
| 8.2(Marking ) |
- |
1000 |
|
- |
| 8.3(Marking ) |
- |
1000 |
|
- |
| 8.4(Marking ) |
- |
1000 |
|
- |
| 8.5(Marking ) |
- |
1000 |
|
- |
| 8.6(Marking ) |
- |
1000 |
|
- |
| 8.7(Marking ) |
- |
1000 |
|
- |
| 8.8(Marking ) |
- |
1000 |
|
- |
| 6(Rating ) |
- |
1000 |
|
- |
| 6(Rating ) |
- |
1000 |
|
- |
| 7(Classification) |
- |
1000 |
|
- |
| 7.2(Classification) |
- |
1000 |
|
- |
| 7.3(Classification) |
- |
1000 |
|
- |
| 7.4(Classification) |
- |
1000 |
|
- |
| 7.5(Classification) |
- |
1000 |
|
- |
| 7.6(Classification) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.2(Dimensions) |
- |
1000 |
|
- |
| 9.3(Dimensions) |
- |
1000 |
|
- |
| 9.3(Dimensions) |
- |
1000 |
|
- |
| 9.3(Dimensions) |
- |
1000 |
|
- |
| 9.3(Dimensions) |
- |
1000 |
|
- |
| 9.3(Dimensions) |
- |
1000 |
|
- |
| 9.3(Dimensions) |
- |
1000 |
|
- |
| 9.3(Dimensions) |
- |
1000 |
|
- |
| 10(Protection against electric shock ) |
- |
1000 |
|
- |
| 11.1(Terminals) |
- |
1000 |
|
- |
| 11.2(Terminals) |
- |
1000 |
|
- |
| 11.3(Terminals) |
- |
1000 |
|
- |
| 11.3(Terminals) |
- |
1000 |
|
- |
| 11.3(Terminals) |
- |
1000 |
|
- |
| 11.3(Terminals) |
- |
1000 |
|
- |
| 11.3(Terminals) |
- |
1000 |
|
- |
| 11.3(Terminals) |
- |
1000 |
|
- |
| 11.4(Terminals) |
- |
1000 |
|
- |
| 12(Provision for Earthing) |
- |
1000 |
|
- |
| 13.1(Construction) |
- |
1000 |
|
- |
| 13.1(Construction (Data Sheet No 7005-10)) |
- |
1000 |
|
- |
| 13.1(Construction (Data Sheet No 7005-10& 7006-15A)) |
- |
1000 |
|
- |
| 13.2(Construction (Data Sheet No 7005-10& 7006-15A)) |
- |
1000 |
|
- |
| 13.3(Construction ) |
- |
1000 |
|
- |
| 13.4(Construction ) |
- |
1000 |
|
- |
| 13.5(Construction) |
- |
1000 |
|
- |
| 13.2 ,13.6 & 13.7 (Construction) |
- |
1000 |
|
- |
| 13.2 ,13.6 & 13.8(Construction) |
- |
1000 |
|
- |
| 13.11(Construction) |
- |
1000 |
|
- |
| 14(Construction) |
- |
1000 |
|
- |
| 15.1(Moisture Resistance, Insulation Resistance and Electric Strength) |
- |
1000 |
|
- |
| 15.2(Moisture Resistance, Insulation Resistance and Electric Strength) |
- |
1000 |
|
- |
| 15.3(Moisture Resistance, Insulation Resistance and Electric Strength) |
- |
1000 |
|
- |
| 16.1(Mechanical Strength) |
- |
1000 |
|
- |
| 16.1(Mechanical Strength) |
- |
1000 |
|
- |
| 16.2(Mechanical Strength) |
- |
1000 |
|
- |
| 16.3(Mechanical Strength) |
- |
1000 |
|
- |
| 16.4(Mechanical Strength) |
- |
1000 |
|
- |
| 16.5(Mechanical Strength) |
- |
1000 |
|
- |
| 16.6 & Table - 6(Mechanical Strength) |
- |
1000 |
|
- |
| 16.7(Mechanical Strength) |
- |
1000 |
|
- |
| 16.8(Mechanical Strength) |
- |
1000 |
|
- |
| 17(Screws,current-carrying parts and connections) |
- |
1000 |
|
- |
| 18(Creepage distances and Clearances) |
- |
1000 |
|
- |
| 18.1, Table 8(Creepage distances and Clearances) |
- |
1000 |
|
- |
| 18.1, Table 8(Creepage distances and Clearances) |
- |
1000 |
|
- |
| 18.1, Table 8(Creepage distances and Clearances) |
- |
1000 |
|
- |
| 18.1, Table 8(Creepage distances and Clearances) |
- |
1000 |
|
- |
| 18.1, Table 8(Creepage distances and Clearances) |
- |
1000 |
|
- |
| 18.1, Table 8(Creepage distances and Clearances) |
- |
1000 |
|
- |
| 18.1, Table 8(Creepage distances and Clearances) |
- |
1000 |
|
- |
| 19.1(General resistance to heat) |
- |
1000 |
|
- |
| 19.2(General resistance to heat) |
- |
1000 |
|
- |
| 19.3(General resistance to heat) |
- |
1000 |
|
- |
| 19.4(Resistance to heat test) |
- |
1000 |
|
- |
| 20.1(Resistance to heat, fire and tracking) |
- |
1000 |
|
- |
| 20.3(Resistance to heat, fire and tracking) |
- |
1000 |
|
- |
| 20.4(Resistance to heat, fire and tracking) |
- |
1000 |
|
- |
| 20.5(Resistance to tracking) |
- |
1000 |
|
- |
| 21.1(Resistance to excessive residual stresses and to rusting) |
- |
1000 |
|
- |
| 21.1(Resistance to excessive residual stresses and to rusting) |
- |
1000 |
|
- |
| 8.1(Marking ) |
- |
1000 |
|
- |
| 8.1(Marking ) |
- |
1000 |
|
- |
| 8.1(Marking ) |
- |
1000 |
|
- |
| 8.1(Marking ) |
- |
1000 |
|
- |
| 8.1(Marking ) |
- |
1000 |
|
- |
| 8.1(Marking ) |
- |
1000 |
|
- |
| 8.1(Marking ) |
- |
1000 |
|
- |
| 8.1(Marking ) |
- |
1000 |
|
- |
| 8.1(Marking ) |
- |
1000 |
|
- |
| 8.1(Marking ) |
- |
1000 |
|
- |
| 8.1(Marking ) |
- |
1000 |
|
- |
| 8.1(Marking ) |
- |
1000 |
|
- |
| 8.1(Marking ) |
- |
1000 |
|
- |
| 8.2(Marking ) |
- |
1000 |
|
- |
| 8.2(Marking ) |
- |
1000 |
|
- |
| 8.2(Marking ) |
- |
1000 |
|
- |
| 8.3(Marking ) |
- |
1000 |
|
- |
| 8.4(Marking ) |
- |
1000 |
|
- |
| 8.5(Marking ) |
- |
1000 |
|
- |
| 8.6(Marking ) |
- |
1000 |
|
- |
| 8.7(Marking ) |
- |
1000 |
|
- |
| 8.8(Marking ) |
- |
1000 |
|
- |
| 6(Rating ) |
- |
1000 |
|
- |
| 6(Rating ) |
- |
1000 |
|
- |
| 7(Classification) |
- |
1000 |
|
- |
| 7.2(Classification) |
- |
1000 |
|
- |
| 7.3(Classification) |
- |
1000 |
|
- |
| 7.4(Classification) |
- |
1000 |
|
- |
| 7.5(Classification) |
- |
1000 |
|
- |
| 7.6(Classification) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.1(Dimensions) |
- |
1000 |
|
- |
| 9.2(Dimensions) |
- |
1000 |
|
- |
| 9.3(Dimensions) |
- |
1000 |
|
- |
| 9.3(Dimensions) |
- |
1000 |
|
- |
| 9.3(Dimensions) |
- |
1000 |
|
- |
| 9.3(Dimensions) |
- |
1000 |
|
- |
| 9.3(Dimensions) |
- |
1000 |
|
- |
| 9.3(Dimensions) |
- |
1000 |
|
- |
| 10(Protection against electric shock ) |
- |
1000 |
|
- |
| 11.1(Terminals) |
- |
1000 |
|
- |
| 11.2(Terminals) |
- |
1000 |
|
- |
| 11.3(Terminals) |
- |
1000 |
|
- |
| 12.3(Terminals) |
- |
1000 |
|
- |
| 11.3(Terminals) |
- |
1000 |
|
- |
| 11.3(Terminals) |
- |
1000 |
|
- |
| 11.3(Terminals) |
- |
1000 |
|
- |
| 11.3(Terminals) |
- |
1000 |
|
- |
| 11.4(Terminals) |
- |
1000 |
|
- |
| 12(Provision for Earthing) |
- |
1000 |
|
- |
| 13.1(Construction) |
- |
1000 |
|
- |
| 13.1(Construction (Data Sheet No 7005-10)) |
- |
1000 |
|
- |
| 13.1(Construction (Data Sheet No 7005-10& 7006-15A)) |
- |
1000 |
|
- |
| 13.2(Construction (Data Sheet No 7005-10& 7006-15A)) |
- |
1000 |
|
- |
| 13.3(Construction ) |
- |
1000 |
|
- |
| 13.4(Construction ) |
- |
1000 |
|
- |
| 13.5(Construction) |
- |
1000 |
|
- |
| 13.2 ,13.6 & 13.7 (Construction) |
- |
1000 |
|
- |
| 13.2 ,13.6 & 13.8(Construction) |
- |
1000 |
|
- |
| 13.11(Construction) |
- |
1000 |
|
- |
| 14(Construction) |
- |
1000 |
|
- |
| 15.1(Moisture Resistance, Insulation Resistance and Electric Strength) |
- |
1000 |
|
- |
| 15.2(Moisture Resistance, Insulation Resistance and Electric Strength) |
- |
1000 |
|
- |
| 15.3(Moisture Resistance, Insulation Resistance and Electric Strength) |
- |
1000 |
|
- |
| 16.1(Mechanical Strength) |
- |
1000 |
|
- |
| 16.1(Mechanical Strength) |
- |
1000 |
|
- |
| 16.2(Mechanical Strength) |
- |
1000 |
|
- |
| 16.3(Mechanical Strength) |
- |
1000 |
|
- |
| 16.4(Mechanical Strength) |
- |
1000 |
|
- |
| 16.5(Mechanical Strength) |
- |
1000 |
|
- |
| 16.6 & Table - 6(Mechanical Strength) |
- |
1000 |
|
- |
| 16.7(Mechanical Strength) |
- |
1000 |
|
- |
| 16.8(Mechanical Strength) |
- |
1000 |
|
- |
| 17(Screws,current-carrying parts and connections) |
- |
1000 |
|
- |
| 18(Creepage distances and Clearances) |
- |
1000 |
|
- |
| 18(Creepage distances and Clearances) |
- |
1000 |
|
- |
| 18(Creepage distances and Clearances) |
- |
1000 |
|
- |
| 18(Creepage distances and Clearances) |
- |
1000 |
|
- |
| 18(Creepage distances and Clearances) |
- |
1000 |
|
- |
| 18(Creepage distances and Clearances) |
- |
1000 |
|
- |
| 18(Creepage distances and Clearances) |
- |
1000 |
|
- |
| 18(Creepage distances and Clearances) |
- |
1000 |
|
- |
| 19.1(General resistance to heat) |
- |
1000 |
|
- |
| 19.2(General resistance to heat) |
- |
1000 |
|
- |
| 19.3(General resistance to heat) |
- |
1000 |
|
- |
| 19.4(Resistance to heat test) |
- |
1000 |
|
- |
| 20.1(Resistance to heat, fire and tracking) |
- |
1000 |
|
- |
| 20.3(Resistance to heat, fire and tracking) |
- |
1000 |
|
- |
| 20.4(Resistance to heat, fire and tracking) |
- |
1000 |
|
- |
| 20.5(Resistance to tracking) |
- |
1000 |
|
- |
| 21.1(Resistance to excessive residual stresses and to rusting) |
- |
1000 |
|
- |
| 21.1(Resistance to excessive residual stresses and to rusting) |
- |
1000 |
|
- |
|
15 Jun, 2026 |
- Included w.e.f.12.12.2024 |
| 9479 |
ATCC TEST LABS LLP
| 8172626
| IS 302 : Part 2 : Sec 75 (2018) |
Safety of Household and Similar Electrical Appliances Part 2 Particular Requirements Section 75 Commercial Dispensing Appliances and Vending Machines |
- |
32500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32(Radiation, toxicity and similar hazards) |
- |
500 |
|
- |
| 31(Resistance to rusting) |
- |
500 |
|
- |
| 30.2.4(Resistance to heat and fire) |
- |
500 |
|
- |
| 30.2(Resistance to heat and fire) |
- |
500 |
|
- |
| 30.1(Resistance to heat and fire) |
- |
500 |
|
- |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
500 |
|
- |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
300 |
|
- |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
200 |
|
- |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
500 |
|
- |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
500 |
|
- |
| 28.2 to 28.4(Screws and connections) |
- |
500 |
|
- |
| 28.1, Table No.-14(Screws and connections) |
- |
500 |
|
- |
| 27.6(Provision for earthing) |
- |
500 |
|
- |
| 27.5(Provision for earthing) |
- |
500 |
|
- |
| 27.1 to 27.4(Provision for earthing) |
- |
500 |
|
- |
| 26.10 & 26.11(Terminals for external conductors) |
- |
500 |
|
- |
| 26.9(Terminals for external conductors) |
- |
500 |
|
- |
| 26.1 to 26.8(Terminals for external conductors) |
- |
300 |
|
- |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
200 |
|
- |
| 25.15(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.14(Supply connection and external flexible cords) |
- |
200 |
|
- |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 25.4(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.3(Supply connection and external flexible cords) |
- |
200 |
|
- |
| 25.2(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 25.1(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 24.101 to 24.103(Components) |
- |
500 |
|
- |
| 24.2 to 24.6(Components) |
- |
500 |
|
- |
| 24.1(Components) |
- |
500 |
|
- |
| 23.101 to 23.102(Internal wiring) |
- |
500 |
|
- |
| 23.6 to 23.10(Internal wiring) |
- |
500 |
|
- |
| 23.5(Internal wiring) |
- |
300 |
|
- |
| 23.4(Internal wiring) |
- |
200 |
|
- |
| 23.3(Internal wiring) |
- |
500 |
|
- |
| 23.1 & 23.2(Internal wiring) |
- |
500 |
|
- |
| 22.101 to 22.114(Constructions) |
- |
500 |
|
- |
| 22.13 to 22.48(Constructions) |
- |
500 |
|
- |
| 22.12(Constructions) |
- |
500 |
|
- |
| 22.11(Constructions) |
- |
300 |
|
- |
| 22.11(Constructions) |
- |
200 |
|
- |
| 22.7 to 22.10(Constructions) |
- |
300 |
|
- |
| 22.6(Constructions) |
- |
200 |
|
- |
| 22.5(Constructions) |
- |
300 |
|
- |
| 22.4(Constructions) |
- |
200 |
|
- |
| 22.3(Constructions) |
- |
300 |
|
- |
| 22.2(Constructions) |
- |
200 |
|
- |
| 22.1(Constructions) |
- |
500 |
|
- |
| 21.2(MECHANICAL STRENGTH) |
- |
300 |
|
- |
| 21.1(MECHANICAL STRENGTH) |
- |
200 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
500 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
500 |
|
- |
| 19.101 and 19.102(ABNORMAL OPERATION) |
- |
500 |
|
- |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
500 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
500 |
|
- |
| 16.3(Insulation resistance test) |
- |
500 |
|
- |
| 16.3(Electric strength test) |
- |
500 |
|
- |
| 16.1 & 16.2(Leakage current test) |
- |
500 |
|
- |
| 15.102(Moisture resistance) |
- |
500 |
|
- |
| 15.102(Moisture resistance) |
- |
500 |
|
- |
| 15.101(Moisture resistance) |
- |
500 |
|
- |
| 15.3(Moisture resistance) |
- |
300 |
|
- |
| 15.2(Moisture resistance) |
- |
200 |
|
- |
| 15.1(Moisture resistance) |
- |
500 |
|
- |
| 14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
500 |
|
- |
| 13.3 and Table No.- 4(Electric strength test) |
- |
300 |
|
- |
| 13.1, 13.2(Leakage current test) |
- |
200 |
|
- |
| 11.1 to 11.8, Table No.-3(Heating) |
- |
500 |
|
- |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
500 |
|
- |
| 8.1.5(Protection against access to live parts) |
- |
500 |
|
- |
| 8.1.4(Protection against access to live parts) |
- |
300 |
|
- |
| 8.1.3(Protection against access to live parts) |
- |
200 |
|
- |
| 8.1.2(Protection against access to live parts) |
- |
500 |
|
- |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
500 |
|
- |
| 7.14(Legibility & Durability of Markings test) |
- |
300 |
|
- |
| 7.1 to 7.13, 7.15, 7.16(Marking) |
- |
200 |
|
- |
| 32(Radiation, toxicity and similar hazards) |
- |
500 |
|
- |
| 31(Resistance to rusting) |
- |
500 |
|
- |
| 30.2.4(Resistance to heat and fire) |
- |
500 |
|
- |
| 30.2(Resistance to heat and fire) |
- |
500 |
|
- |
| 30.1(Resistance to heat and fire) |
- |
500 |
|
- |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
500 |
|
- |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
300 |
|
- |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
200 |
|
- |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
500 |
|
- |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
500 |
|
- |
| 28.2 to 28.4(Screws and connections) |
- |
500 |
|
- |
| 28.1, Table No.-14(Screws and connections) |
- |
500 |
|
- |
| 27.6(Provision for earthing) |
- |
500 |
|
- |
| 27.5(Provision for earthing) |
- |
500 |
|
- |
| 27.1 to 27.4(Provision for earthing) |
- |
500 |
|
- |
| 26.10 & 26.11(Terminals for external conductors) |
- |
500 |
|
- |
| 26.9(Terminals for external conductors) |
- |
500 |
|
- |
| 26.1 to 26.8(Terminals for external conductors) |
- |
300 |
|
- |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
200 |
|
- |
| 25.15(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.14(Supply connection and external flexible cords) |
- |
200 |
|
- |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 25.4(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.3(Supply connection and external flexible cords) |
- |
200 |
|
- |
| 25.2(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 25.1(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 24.101 to 24.103(Components) |
- |
500 |
|
- |
| 24.2 to 24.6(Components) |
- |
500 |
|
- |
| 24.1(Components) |
- |
500 |
|
- |
| 23.101 to 23.102(Internal wiring) |
- |
500 |
|
- |
| 23.6 to 23.10(Internal wiring) |
- |
500 |
|
- |
| 23.5(Internal wiring) |
- |
300 |
|
- |
| 23.4(Internal wiring) |
- |
200 |
|
- |
| 23.3(Internal wiring) |
- |
500 |
|
- |
| 23.1 & 23.2(Internal wiring) |
- |
500 |
|
- |
| 22.101 to 22.114(Constructions) |
- |
500 |
|
- |
| 22.13 to 22.48(Constructions) |
- |
500 |
|
- |
| 22.12(Constructions) |
- |
500 |
|
- |
| 22.11(Constructions) |
- |
300 |
|
- |
| 22.11(Constructions) |
- |
200 |
|
- |
| 22.7 to 22.10(Constructions) |
- |
300 |
|
- |
| 22.6(Constructions) |
- |
200 |
|
- |
| 22.5(Constructions) |
- |
300 |
|
- |
| 22.4(Constructions) |
- |
200 |
|
- |
| 22.3(Constructions) |
- |
300 |
|
- |
| 22.2(Constructions) |
- |
200 |
|
- |
| 22.1(Constructions) |
- |
500 |
|
- |
| 21.2(MECHANICAL STRENGTH) |
- |
300 |
|
- |
| 21.1(MECHANICAL STRENGTH) |
- |
200 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
500 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
500 |
|
- |
| 19.101 and 19.102(ABNORMAL OPERATION) |
- |
500 |
|
- |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
500 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
500 |
|
- |
| 16.3(Insulation resistance test) |
- |
500 |
|
- |
| 16.3(Electric strength test) |
- |
500 |
|
- |
| 16.1 & 16.2(Leakage current test) |
- |
500 |
|
- |
| 15.102(Moisture resistance) |
- |
500 |
|
- |
| 15.102(Moisture resistance) |
- |
500 |
|
- |
| 15.101(Moisture resistance) |
- |
500 |
|
- |
| 15.3(Moisture resistance) |
- |
300 |
|
- |
| 15.2(Moisture resistance) |
- |
200 |
|
- |
| 15.1(Moisture resistance) |
- |
500 |
|
- |
| 14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
500 |
|
- |
| 13.3 and Table No.- 4(Electric strength test) |
- |
300 |
|
- |
| 13.1, 13.2(Leakage current test) |
- |
200 |
|
- |
| 11.1 to 11.8, Table No.-3(Heating) |
- |
500 |
|
- |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
500 |
|
- |
| 8.1.5(Protection against access to live parts) |
- |
500 |
|
- |
| 8.1.4(Protection against access to live parts) |
- |
300 |
|
- |
| 8.1.3(Protection against access to live parts) |
- |
200 |
|
- |
| 8.1.2(Protection against access to live parts) |
- |
500 |
|
- |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
500 |
|
- |
| 7.14(Legibility & Durability of Markings test) |
- |
300 |
|
- |
| 7.1 to 7.13, 7.15, 7.16(Marking) |
- |
200 |
|
- |
| 32(Radiation, toxicity and similar hazards) |
- |
500 |
|
- |
| 31(Resistance to rusting) |
- |
500 |
|
- |
| 30.2.4(Resistance to heat and fire) |
- |
500 |
|
- |
| 30.2(Resistance to heat and fire) |
- |
500 |
|
- |
| 30.1(Resistance to heat and fire) |
- |
500 |
|
- |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
500 |
|
- |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
300 |
|
- |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
200 |
|
- |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
500 |
|
- |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
500 |
|
- |
| 28.2 to 28.4(Screws and connections) |
- |
500 |
|
- |
| 28.1, Table No.-14(Screws and connections) |
- |
500 |
|
- |
| 27.6(Provision for earthing) |
- |
500 |
|
- |
| 27.5(Provision for earthing) |
- |
500 |
|
- |
| 27.1 to 27.4(Provision for earthing) |
- |
500 |
|
- |
| 26.10 & 26.11(Terminals for external conductors) |
- |
500 |
|
- |
| 26.9(Terminals for external conductors) |
- |
500 |
|
- |
| 26.1 to 26.8(Terminals for external conductors) |
- |
300 |
|
- |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
200 |
|
- |
| 25.15(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.14(Supply connection and external flexible cords) |
- |
200 |
|
- |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 25.4(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.3(Supply connection and external flexible cords) |
- |
200 |
|
- |
| 25.2(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 25.1(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 24.101 to 24.103(Components) |
- |
500 |
|
- |
| 24.2 to 24.6(Components) |
- |
500 |
|
- |
| 24.1(Components) |
- |
500 |
|
- |
| 23.101 to 23.102(Internal wiring) |
- |
500 |
|
- |
| 23.6 to 23.10(Internal wiring) |
- |
500 |
|
- |
| 23.5(Internal wiring) |
- |
300 |
|
- |
| 23.4(Internal wiring) |
- |
200 |
|
- |
| 23.3(Internal wiring) |
- |
500 |
|
- |
| 23.1 & 23.2(Internal wiring) |
- |
500 |
|
- |
| 22.101 to 22.114(Constructions) |
- |
500 |
|
- |
| 22.13 to 22.48(Constructions) |
- |
500 |
|
- |
| 22.12(Constructions) |
- |
500 |
|
- |
| 22.11(Constructions) |
- |
300 |
|
- |
| 22.11(Constructions) |
- |
200 |
|
- |
| 22.7 to 22.10(Constructions) |
- |
300 |
|
- |
| 22.6(Constructions) |
- |
200 |
|
- |
| 22.5(Constructions) |
- |
300 |
|
- |
| 22.4(Constructions) |
- |
200 |
|
- |
| 22.3(Constructions) |
- |
300 |
|
- |
| 22.2(Constructions) |
- |
200 |
|
- |
| 22.1(Constructions) |
- |
500 |
|
- |
| 21.2(MECHANICAL STRENGTH) |
- |
300 |
|
- |
| 21.1(MECHANICAL STRENGTH) |
- |
200 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
500 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
500 |
|
- |
| 19.101 and 19.102(ABNORMAL OPERATION) |
- |
500 |
|
- |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
500 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
500 |
|
- |
| 16.3(Insulation resistance test) |
- |
500 |
|
- |
| 16.3(Electric strength test) |
- |
500 |
|
- |
| 16.1 & 16.2(Leakage current test) |
- |
500 |
|
- |
| 15.102(Moisture resistance) |
- |
500 |
|
- |
| 15.102(Moisture resistance) |
- |
500 |
|
- |
| 15.101(Moisture resistance) |
- |
500 |
|
- |
| 15.3(Moisture resistance) |
- |
300 |
|
- |
| 15.2(Moisture resistance) |
- |
200 |
|
- |
| 15.1(Moisture resistance) |
- |
500 |
|
- |
| 14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
500 |
|
- |
| 13.3 and Table No.- 4(Electric strength test) |
- |
300 |
|
- |
| 13.1, 13.2(Leakage current test) |
- |
200 |
|
- |
| 11.1 to 11.8, Table No.-3(Heating) |
- |
500 |
|
- |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
500 |
|
- |
| 8.1.5(Protection against access to live parts) |
- |
500 |
|
- |
| 8.1.4(Protection against access to live parts) |
- |
300 |
|
- |
| 8.1.3(Protection against access to live parts) |
- |
200 |
|
- |
| 8.1.2(Protection against access to live parts) |
- |
500 |
|
- |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
500 |
|
- |
| 7.14(Legibility & Durability of Markings test) |
- |
300 |
|
- |
| 7.1 to 7.13, 7.15, 7.16(Marking) |
- |
200 |
|
- |
| 32(Radiation, toxicity and similar hazards) |
- |
500 |
|
- |
| 31(Resistance to rusting) |
- |
500 |
|
- |
| 30.2.4(Resistance to heat and fire) |
- |
500 |
|
- |
| 30.2(Resistance to heat and fire) |
- |
500 |
|
- |
| 30.1(Resistance to heat and fire) |
- |
500 |
|
- |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
500 |
|
- |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
300 |
|
- |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
200 |
|
- |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
500 |
|
- |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
500 |
|
- |
| 28.2 to 28.4(Screws and connections) |
- |
500 |
|
- |
| 28.1, Table No.-14(Screws and connections) |
- |
500 |
|
- |
| 27.6(Provision for earthing) |
- |
500 |
|
- |
| 27.5(Provision for earthing) |
- |
500 |
|
- |
| 27.1 to 27.4(Provision for earthing) |
- |
500 |
|
- |
| 26.10 & 26.11(Terminals for external conductors) |
- |
500 |
|
- |
| 26.9(Terminals for external conductors) |
- |
500 |
|
- |
| 26.1 to 26.8(Terminals for external conductors) |
- |
300 |
|
- |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
200 |
|
- |
| 25.15(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.14(Supply connection and external flexible cords) |
- |
200 |
|
- |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 25.4(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.3(Supply connection and external flexible cords) |
- |
200 |
|
- |
| 25.2(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 25.1(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 24.101 to 24.103(Components) |
- |
500 |
|
- |
| 24.2 to 24.6(Components) |
- |
500 |
|
- |
| 24.1(Components) |
- |
500 |
|
- |
| 23.101 to 23.102(Internal wiring) |
- |
500 |
|
- |
| 23.6 to 23.10(Internal wiring) |
- |
500 |
|
- |
| 23.5(Internal wiring) |
- |
300 |
|
- |
| 23.4(Internal wiring) |
- |
200 |
|
- |
| 23.3(Internal wiring) |
- |
500 |
|
- |
| 23.1 & 23.2(Internal wiring) |
- |
500 |
|
- |
| 22.101 to 22.114(Constructions) |
- |
500 |
|
- |
| 22.13 to 22.48(Constructions) |
- |
500 |
|
- |
| 22.12(Constructions) |
- |
500 |
|
- |
| 22.11(Constructions) |
- |
300 |
|
- |
| 22.11(Constructions) |
- |
200 |
|
- |
| 22.7 to 22.10(Constructions) |
- |
300 |
|
- |
| 22.6(Constructions) |
- |
200 |
|
- |
| 22.5(Constructions) |
- |
300 |
|
- |
| 22.4(Constructions) |
- |
200 |
|
- |
| 22.3(Constructions) |
- |
300 |
|
- |
| 22.2(Constructions) |
- |
200 |
|
- |
| 22.1(Constructions) |
- |
500 |
|
- |
| 21.2(MECHANICAL STRENGTH) |
- |
300 |
|
- |
| 21.1(MECHANICAL STRENGTH) |
- |
200 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
500 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
500 |
|
- |
| 19.101 and 19.102(ABNORMAL OPERATION) |
- |
500 |
|
- |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
500 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
500 |
|
- |
| 16.3(Insulation resistance test) |
- |
500 |
|
- |
| 16.3(Electric strength test) |
- |
500 |
|
- |
| 16.1 & 16.2(Leakage current test) |
- |
500 |
|
- |
| 15.102(Moisture resistance) |
- |
500 |
|
- |
| 15.102(Moisture resistance) |
- |
500 |
|
- |
| 15.101(Moisture resistance) |
- |
500 |
|
- |
| 15.3(Moisture resistance) |
- |
300 |
|
- |
| 15.2(Moisture resistance) |
- |
200 |
|
- |
| 15.1(Moisture resistance) |
- |
500 |
|
- |
| 14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
500 |
|
- |
| 13.3 and Table No.- 4(Electric strength test) |
- |
300 |
|
- |
| 13.1, 13.2(Leakage current test) |
- |
200 |
|
- |
| 11.1 to 11.8, Table No.-3(Heating) |
- |
500 |
|
- |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
500 |
|
- |
| 8.1.5(Protection against access to live parts) |
- |
500 |
|
- |
| 8.1.4(Protection against access to live parts) |
- |
300 |
|
- |
| 8.1.3(Protection against access to live parts) |
- |
200 |
|
- |
| 8.1.2(Protection against access to live parts) |
- |
500 |
|
- |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
500 |
|
- |
| 7.14(Legibility & Durability of Markings test) |
- |
300 |
|
- |
| 7.1 to 7.13, 7.15, 7.16(Marking) |
- |
200 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
500 |
|
- |
| 19.11.4.7(Harmonics) |
- |
500 |
|
- |
|
15 Jun, 2026 |
- Included w.e.f.11.12.2024
Exclusion
CL 19.11.4.1 (Electrostatic discharges)
CL 19.11.4.2 (Radiated fields)
CL 19.11.4.3 (Fast transient bursts)
CL 19.11.4.5 (Immunity to conducted discharges)
CL 19.11.4.6 (Class 3 Voltage dips and interruptions) |
| 9480 |
ATCC TEST LABS LLP
| 8172626
| IS 302 : Part 2 : SEC 31 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 31 range hoods |
- |
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
2000 |
|
- |
| Clause No - 5.18(linear and angular dimension) |
- |
2000 |
|
- |
| Clause No - 6.2(harmfull ingress of water) |
- |
2000 |
|
- |
| Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
2000 |
|
- |
| Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
2000 |
|
- |
| Clause No - 8.2(Addition) |
- |
2000 |
|
- |
| Clause No - 10.1, Table No. -1(power input deviation) |
- |
2000 |
|
- |
| Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
2000 |
|
- |
| Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
2000 |
|
- |
| Clause No - 14(Impulse test voltage) |
- |
2000 |
|
- |
| Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
2000 |
|
- |
| Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
2000 |
|
- |
| Clause No -21.1(Mechanical strength) |
- |
2000 |
|
- |
| Clause No -22.1(construction) |
- |
2000 |
|
- |
| Clause No -22.11(push force applied) |
- |
2000 |
|
- |
| Clause No -24.1.2(safety isolating transformer) |
- |
2000 |
|
- |
| Clause No -24.1.3(for switches) |
- |
2000 |
|
- |
| Clause No -24.1.4(for automatic control) |
- |
2000 |
|
- |
| Clause No -24.1.5(for innterconnection couplers) |
- |
2000 |
|
- |
| Clause No -25.8, Table no -11(conductor resistance) |
- |
2000 |
|
- |
| Clause No -25.5(dimension for pins) |
- |
2000 |
|
- |
| Clause No -27.6(for circuit board) |
- |
2000 |
|
- |
| Clause No -29.2(comparative tracking index) |
- |
2000 |
|
- |
| Clause No -29.3.3(dry heat test) |
- |
2000 |
|
- |
| Clause No -30.2.1(glow wire test) |
- |
2000 |
|
- |
| Clause No -30.101("incorporate combustible
material") |
- |
2000 |
|
- |
| Clause No -24.4(plug and socket) |
- |
2000 |
|
- |
|
15 Jun, 2026 |
- Exclusion: Clause No -19.11.4.1 (electrostatic discharge)
Clause No -19.11.4.2 (radiated field)
Clause No -19.11.4.3 (fast transient)
Clause No -19.11.4.4 (Voltage dips and interruption) |