10051 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 8329 (2000) |
Centrifugally cast (Spun) ductile iron pressure pipes for water, gas and sewage - Specification (Third Revision) |
For all sizes |
Rs.7800/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 10 (Hardness & Tensile Test) |
- |
|
|
|
Cl 13 (Length, Diameter, Wall Thickness & Ovality) |
- |
|
|
|
Cl 13 (Length, Diameter, Wall Thickness & Ovality) |
- |
|
|
|
Cl 13 (Length, Diameter, Wall Thickness & Ovality) |
- |
|
|
|
|
- |
- Hydrostatic test
Required Cut pc for coating, Cut potion for dimension, cement lining, prepared test pc for tensile, hardness |
10052 |
BIS, Central Laboratory (CL)
| None
| IS 14899 (2014) |
Liquefied petroleum gas (LPG) containers for automotive use - Specification (First Revision) |
- |
- View breakup
Rs. 21363/- (excluding Out of roundness, Hardness test, Pneumatic test, Radiographic examination, Bonfire test, Crash test and Strength assessment) + testing charges as per referred ISS.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
10.1.5 (Inner surface in tension) |
- |
|
|
|
10.1.5 (Outer surface in tension) |
- |
|
|
|
10.1.6 (Macroscopic Examination On Circumferential Weld ) |
- |
|
|
|
10.1.6 (Macroscopic Examination On longitudinal Weld) |
- |
|
|
|
10.1.6.1 (Macroscopic Examination, m1,Through valve boss ) |
- |
|
|
|
10.1.6.1 (Macroscopic Examination, m2,Through valve plate welds) |
- |
|
|
|
10.1.8 (Water Capacity) |
- |
|
|
|
10.2.1 (Hydrostatic stretch test) |
- |
|
|
|
10.2.2 (Burst test) |
- |
|
|
|
10.2.3.2 (Change in volume,) |
- |
|
|
|
10.2.3.3 (shall not cause any fragmentation ) |
- |
|
|
|
10.3 (Hydrostatic Test,3 MPa for 60 seconds ) |
- |
|
|
|
10.6.2 (Fatigue Test) |
- |
|
|
|
11 (Surface coating and colour) |
- |
|
|
|
10.1 (Macroscopic Examination) |
- |
|
|
|
10.3 (Hydrostatic Test,3 MPa for 60 seconds ) |
- |
|
|
|
|
- |
- Excluding -; Circumferential Weld (Cl 7.2.2.2),Out of Roundness (Cl 7.3)Hydrostatic Stretch Test (Cl 10.2.1)Pneumatic Leakage Test (Cl 10.4)Bonfire Test (Cl 10.6.1)Radiographic Examination (Cl 10.5.1)Radiographic Examination (Cl 10.5.1)Bonfire Test (Cl 10.6.1)Fatigue Test (Cl 10.6.2)Crash Test (Cl 10.6.3)Strength Assessment (Cl 10.6.4) |
10053 |
BIS, Central Laboratory (CL)
| None
| IS 8978 (1992) |
Specification for electric instantaneous water heaters (Second Revision) |
- |
Rs.15030/ View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6 of IS 302-2-35:2017 (Classification) |
- |
|
|
|
Cl.6 of IS 302-2-35:2017 (Classification) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.8 of IS 302-2-35:2017 (Protection Against Access To Live Parts) |
- |
|
|
|
Cl.10 of IS 302-2- 35:2011 (Power Input & Current ) |
- |
|
|
|
Cl.11 of 302-2-35:2017 (Heating) |
- |
|
|
|
Cl.11 of 302-2-35:2017 (Heating) |
- |
|
|
|
Cl.11 of 302-2-35:2017 (Heating) |
- |
|
|
|
Cl.11 of 302-2-35:2017 (Heating) |
- |
|
|
|
Cl.13 of IS 302-2-35:2017 (Leakage Current & Electrical Strength at Operating Temperature ) |
- |
|
|
|
Cl.13 of IS 302-2-35:2017 (Leakage Current & Electrical Strength at Operating Temperature ) |
- |
|
|
|
Cl.15 of IS 302-2-35-2011 (Moisture Resistance ) |
- |
|
|
|
Cl.15 of IS 302-2-35-2011 (Moisture Resistance ) |
- |
|
|
|
Cl.16 of IS 302-2-35:2011 (Leakage Current and Electric Strength) |
- |
|
|
|
Cl.16 of IS 302-2-35:2011 (Leakage Current and Electric Strength) |
- |
|
|
|
Cl.19 of IS 302-2-35:2017 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-35:2017 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-35:2017 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-35:2017 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-35:2017 (Abnormal Operation) |
- |
|
|
|
Cl.20 of IS 302-2-35-2011 (Stability & Mechanical Hazards
) |
- |
|
|
|
Cl.21.1 of IS 302-2-35-2011 (Mechanical strength) |
- |
|
|
|
Cl. 21.2 of IS 302-1:2008 (Mechanical strength) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.27 of IS 302-2-35:2017 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 302-2-35:2017 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 302-2-35:2017 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 302-2-35:2017 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 302-2-35:2017 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 302-2-35:2017 (Provision for Earthing) |
- |
|
|
|
Cl.28 of IS 302-2-35:2017 (Screws and Connections
) |
- |
|
|
|
Cl.29 of IS 302-2-35:2017 (Clearances, Creepage Distances and Solid Insulation) |
- |
|
|
|
Cl.29 of IS 302-2-35:2017 (Clearances, Creepage Distances and Solid Insulation) |
- |
|
|
|
Cl.30 of IS 302-2-35: 2011 (Resistance to Heat and Fire) |
- |
|
|
|
Cl.30 of IS 302-2-35: 2011 (Resistance to Heat and Fire) |
- |
|
|
|
Cl.31 of IS 302-2-35: 2011 (Resistance to Rusting
) |
- |
|
|
|
Cl.32 of IS 302-2-35: 2011 (Radiation, Toxicity and Similar Hazards
) |
- |
|
|
|
Cl.10 of IS 8978 : 1992 (Finish) |
- |
|
|
|
Cl.11 of IS 8978 : 1992 (Operation of flow switch) |
- |
|
|
|
Cl.12 of IS 8978 : 1992 (Endurance) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7.1 of IS 302-2-35:2017 (Marking : rated pressure) |
- |
|
|
|
Cl.7.101 of IS 302-2-35:2017 (Marking : Woter inlet and outlet idetification) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.23 of IS 302-2-35-2011 (Internal Wiring) |
- |
|
|
|
Cl.24 of IS 302-2-35:2017 (Component
) |
- |
|
|
|
Cl.25.8 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords : Resistance of supply cord ) |
- |
|
|
|
Cl.27.5 of IS 302-2-35:2017 (Provision for Earthing : ECR ) |
- |
|
|
|
|
- |
- Complete except electronic circuit type appliances(IS 302-2-21, IS 302-1) |
10054 |
BIS, Central Laboratory (CL)
| None
| IS 14846 (2000) |
Sluice valve for water works purposes (50 To 1200 mm size) - specification |
- |
complete testing charges for the product are Rs.5700.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (Nominal Pressures) |
- |
|
|
|
5.1 (Nominal Sizes) |
- |
|
|
|
5.1.1 (Actual Bore) |
- |
|
|
|
7.2.2 (Manufacture - Bodies and Bonnets) |
- |
|
|
|
7.2.3 (Manufacture) |
- |
|
|
|
7.2.4 (Manufacture) |
- |
|
|
|
7.3 Table 3A 1 (Flanges) |
- |
|
|
|
7.3 Table 3A 2 (Flanges) |
- |
|
|
|
7.3 Table 3A 3 (Flanges) |
- |
|
|
|
7.3 Table 3A 4 (Flanges) |
- |
|
|
|
7.3 Table 3A 5 (Flanges) |
- |
|
|
|
7.3 Table 3A 6 (Flanges) |
- |
|
|
|
7.4.1 (Wedges ) |
- |
|
|
|
7.4.1 (Wedges) |
- |
|
|
|
7.5 (Guides and Lugs) |
- |
|
|
|
7.5 (Guides and Lugs) |
- |
|
|
|
7.5.1 (Guides and Lugs) |
- |
|
|
|
7.6 Table 4 (Facing or Seat Rings) |
- |
|
|
|
7.6 Table 4 (Facing or Seat Rings) |
- |
|
|
|
7.6 Table 4 (Facing or Seat Rings) |
- |
|
|
|
7.6 Table 4 (Facing or Seat Rings) |
- |
|
|
|
7.7.1 Table 2,3 (Dimension of Stem and Wedge Nuts) |
- |
|
|
|
7.7.1 Table 2,3 (Dimension of Stem and Wedge Nuts) |
- |
|
|
|
7.7.1 Table 2,3 (Dimension of Stem and Wedge Nuts) |
- |
|
|
|
7.7.1 Table 2,3 (Dimension of Stem and Wedge Nuts) |
- |
|
|
|
7.7.1 Table 2,5 (Dimension of Stem and Wedge Nuts) |
- |
|
|
|
7.7.2 (Stem and Wedge Nuts) |
- |
|
|
|
7.7.3 (Stem and Wedge Nuts) |
- |
|
|
|
7.7.4 (Stem and Wedge Nuts) |
- |
|
|
|
7.9 (Height of Valve) |
- |
|
|
|
7.1 (Gears) |
- |
|
|
|
7.11 (Hand Wheel) |
- |
|
|
|
7.11 (Hand Wheel) |
- |
|
|
|
7.11 (Hand Wheel) |
- |
|
|
|
7.12 (Valve Caps) |
- |
|
|
|
7.12 (Valve Caps) |
- |
|
|
|
7.12 (Valve Caps) |
- |
|
|
|
7.13 Table 2, 3 (Stuffing Box ) |
- |
|
|
|
7.13 Table 2, 3 (Stuffing Box ) |
- |
|
|
|
7.13 Table 2, 3 (Stuffing Box ) |
- |
|
|
|
7.13 Table 2, 3 (Stuffing Box ) |
- |
|
|
|
7.14 (By Pass Arrangements) |
- |
|
|
|
7.14 (By Pass Arrangements) |
- |
|
|
|
8 (Accessories or Optical Features) |
- |
|
|
|
9 (Coating) |
- |
|
|
|
Cl.6, Table-1 (CARBON) |
- |
|
|
|
Cl.6, Table-1 (SULPHUR) |
- |
|
|
|
Cl.6, Table-1 (PHOSPHURS) |
- |
|
|
|
Cl.6, Table-1 (MANGANESE) |
- |
|
|
|
Cl.6, Table-1 (SILICON) |
- |
|
|
|
Cl.6, Table-1 (ALUMINIUM) |
- |
|
|
|
Cl.6, Table-1 (NITROGEN) |
- |
|
|
|
Cl.6, Table-1 (CHROMIUM) |
- |
|
|
|
Cl.6, Table-1 (NIOBIUM) |
- |
|
|
|
Cl.6, Table-1 (NICKEL) |
- |
|
|
|
Cl.6, Table-1 (VANADIUM) |
- |
|
|
|
Cl.6, Table-1 (TITANIUM) |
- |
|
|
|
Cl.6, Table-1 (MOLYBDENUM) |
- |
|
|
|
Cl.6, Table-1 (ZINC) |
- |
|
|
|
Cl.6, Table-1 (CADMIUM) |
- |
|
|
|
Cl.6, Table-1 (IRON) |
- |
|
|
|
Cl.6, Table-1 (TIN) |
- |
|
|
|
Cl.6, Table-1 (COPPER) |
- |
|
|
|
Cl.6, Table-1 (INDIUM) |
- |
|
|
|
Cl.6, Table-1 (TOTAL IMPURITIES) |
- |
|
|
|
|
- |
- -; Complete (up to 200 mm size) |
10055 |
BIS, Central Laboratory (CL)
| None
| IS 3725 (1966) |
Specification for resistance wires, tapes and strips for heating flements |
- |
Rs 1500.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (Physical Condition, IS 3725) |
- |
|
|
|
4.2 (Physical Dimensions, IS 3725) |
- |
|
|
|
4.2 (Physical Dimensions, IS 3725) |
- |
|
|
|
4.4 (Physical and Mechanical Properties, IS 3725) |
- |
|
|
|
4.4.1 (Physical and Mechanical Properties, IS 3725) |
- |
|
|
|
4.4.2 (Physical and Mechanical Properties, IS 3725) |
- |
|
|
|
4.4.3 (Physical and Mechanical Properties, IS 3725) |
- |
|
|
|
4.5 (Tensile Properties, IS 3725) |
- |
|
|
|
4.5 (Tensile Properties, IS 3725) |
- |
|
|
|
5.1 (Resistance, IS 3725) |
- |
|
|
|
5.2 (Uniformity of Resistance, IS 3725) |
- |
|
|
|
5.2.1 (Uniformity of Resistance, IS 3725) |
- |
|
|
|
7.3.1 (Wrapping Test- Round wire, IS 3725) |
- |
|
|
|
7.3.2 (Wrapping Test- Strips and tapes, IS 3725) |
- |
|
|
|
6.1 (Marking, IS 3725) |
- |
|
|
|
6.1 (Marking, IS 3725) |
- |
|
|
|
6.1 (Marking, IS 3725) |
- |
|
|
|
6.1 (Marking, IS 3725) |
- |
|
|
|
6.1 (Marking, IS 3725) |
- |
|
|
|
6.1 (Marking, IS 3725) |
- |
|
|
|
6.1 (Marking, IS 3725) |
- |
|
|
|
6.1 (Marking, IS 3725) |
- |
|
|
|
6.1.1 (Marking, IS 3725) |
- |
|
|
|
6.2 (Packing, IS 3725) |
- |
|
|
|
|
- |
- Excluding Endurance Test; |
10056 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 3224 (2002) |
Valve fittings for compressed gas cylinders excluding liquefied petroleum gas (LPG) cylinders - Specification (Third Revision) |
- |
Rs 11790.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.2.1.1.1 (Aluminiumsilicon bronze : Copper) |
- |
|
|
|
5.2.1.1.1 ( Lead ) |
- |
|
|
|
5.2.1.1.1 ( Iron) |
- |
|
|
|
5.2.1.1.1 ( Silicon) |
- |
|
|
|
5.2.1.1.1 (Manganese) |
- |
|
|
|
5.2.1.1.2 (Brass: Copper) |
- |
|
|
|
5.2.1.1.2 (Lead:) |
- |
|
|
|
5.2.1.1.2 (Iron) |
- |
|
|
|
5.2.1.1.2 (Manganese) |
- |
|
|
|
5.1.1.2 (Valve Spindle: Ni) |
- |
|
|
|
5.1.1.2 (Cu) |
- |
|
|
|
5.1.1.2 (Fe) |
- |
|
|
|
5.1.1.2 (Mn) |
- |
|
|
|
5.1.1.2 (Si) |
- |
|
|
|
6.2 (see Note and Tables 7 and 8). (Valve dimensions) |
- |
|
|
|
5.3.1 (Tensile Strength- IS 1608) |
- |
|
|
|
5.3.1 (Elongation- IS 1608) |
- |
|
|
|
5.3.2 (Izod impact strength-IS 1598 for for steel) |
- |
|
|
|
|
- |
- Material of construction and Components needs to be specified.
Chem: Except Al, Sn, Si, As
Mech: Except outlet and inlet threads, type tests, routine tests |
10057 |
BIS, Central Laboratory (CL)
| None
| IS 15652 (2006) |
Insulating mats for electrical purposes - Specification |
- |
- View breakup
Rs. 11220/- excluding Di-electric properties, Thermal properties and Extreme low temperature.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9 (Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
|
|
|
9 (Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
|
|
|
9 (Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
|
|
|
9 (Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
|
|
|
9 (Marking (As per Cl.9.2 of IS 15652 : 2006)) |
- |
|
|
|
10.a) (Packing) |
- |
|
|
|
10.b) (Packing) |
- |
|
|
|
10.c) (Packing) |
- |
|
|
|
4 (Classification and Designation (As per Cl.4.1 and Table-1 of IS 15652 : 2006)) |
- |
|
|
|
4 (Classification and Designation (As per Cl.4.2 of IS 15652 : 2006)) |
- |
|
|
|
4 (Classification and Designation (As per Cl.4.2 of IS 15652 : 2006)) |
- |
|
|
|
5 (Composition (As per Cl. 5.1 of IS 15652 : 2006)) |
- |
|
|
|
5 (Composition (As per Cl. 5.2 of IS 15652 : 2006)) |
- |
|
|
|
6 (Shape Requirements and Dimension (As per Cl.6.1 & 6.2 of IS 15652 : 2006)) |
- |
|
|
|
6 (Shape Requirements and Dimension (As per Cl.6.1 & 6.2 of IS 15652 : 2006)) |
- |
|
|
|
6 (Thickness [mm] (As per Cl. 6.3 and Table-2 of IS 15652 : 2006)) |
- |
|
|
|
6 (Colour (As per Cl. 6.4 of IS 15652 : 2006)) |
- |
|
|
|
7 (Workmanship & Finish (As per Cl. 7.1 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.1 and Table - 3 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.1 and Table - 3 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.3 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.3 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
|
|
|
|
- |
- Excluding Die Electric Properties / Thermal properties / Extreme Low Temperature Test; |
10058 |
BIS, Central Laboratory (CL)
| None
| IS 3745 (2006) |
Yoke type valve connections for small medical gas cylinders - Specification (Second Revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.2.1 i) (i)Tensile Strength ) |
- |
|
|
|
3.2.1 ii) ( Elongation) |
- |
|
|
|
3.2.2 (The izod impact strength) |
- |
|
|
|
5.1.2 (Stress Corrosion Testfor Copper Alloy Valve Bodies ) |
- |
|
|
|
5.3.1 (Types of ‘Valves and their Minimum Constructional Requirements) |
- |
|
|
|
5.3.3 (Types of ‘Valves and their Minimum Constructional Requirements) |
- |
|
|
|
5.3.4 (Types of ‘Valves and their Minimum Constructional Requirements) |
- |
|
|
|
5.3.6 (Types of ‘Valves and their Minimum Constructional Requirements) |
- |
|
|
|
6.1 Fig, 2 (BASIC “DIMENS1ONS FOR YOKE TYPE VALVE CONNECTIONS) |
- |
|
|
|
6.2 , Fig. 3. (BASIC “DIMENS1ONS FOR YOKE TYPE VALVE CONNECTIONS) |
- |
|
|
|
10 (HYDROSTATIC TESTS) |
- |
|
|
|
|
- |
- Excluding -; TF not available for Cr plating and Cycle test |
10059 |
BIS, Central Laboratory (CL)
| None
| IS 1879 (2010) |
Malleable cast iron pipe fittings - Specification (Third Revision) |
- |
Rs.7800.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1.1 (Type of Fittings - IS 1879) |
- |
|
|
|
5.1.2 (Size designation - IS 1879) |
- |
|
|
|
5.1.2.1 (Equal fitting - IS 1879) |
- |
|
|
|
5.1.2.2 (Unequal fitting -IS 1879) |
- |
|
|
|
5.1.3 (Right and Left hand thread - IS 1879) |
- |
|
|
|
5.1.1 (Code Number -IS 1879) |
- |
|
|
|
6.1 (Tensile Strength - IS 14329) |
- |
|
|
|
6.1 (Elongation - Is 14329) |
- |
|
|
|
7.2- Table 2 (Wall thickness of fittings - IS 1879) |
- |
|
|
|
7.5 - Table 2 (Projection of Rainforcement - IS 1879) |
- |
|
|
|
7.5 - Table 3 (Width of Rainforcement - IS 1879) |
- |
|
|
|
7.1 - Table 4 to Table 27 (a - IS 1879) |
- |
|
|
|
7.1 - Table 4 to Table 27 (b - IS 1879) |
- |
|
|
|
7.1 - Table 4 to Table 27 (c- IS 1879) |
- |
|
|
|
7.1 - Table 4 to Table 27 (d- IS 1879) |
- |
|
|
|
7.1 - Table 28 (d -IS 1879) |
- |
|
|
|
7.1 - Table 28 (D - IS 1879) |
- |
|
|
|
9 (Freedom from defects
) |
- |
|
|
|
10.i) (Mass of Galvanized coating ) |
- |
|
|
|
10.ii) ( Uniformity of Galvanized coating-IS 2633) |
- |
|
|
|
10.iii) (Adhesion of Galvanized coating IS 2629) |
- |
|
|
|
10.iv) (Freedom from defects IS 4759) |
- |
|
|
|
11 (Pressure Test) |
- |
|
|
|
12 (Compression Test) |
- |
|
|
|
|
- |
- excluding -; Alignment of Threads,Compression test |
10060 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 14968 (2015) |
Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sacks for packing 50 Kg/25 kg sugar – Specification (first revision) |
- |
- View breakup
Rs. 9400/-(Excluding UV Resistance(Breaking strength, elongation after radiation and weathering))
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.2 and Table 1 x (Ash content ) |
- |
|
|
|
4.3.1 (Bottom Seam) |
- |
|
|
|
4.3.1 (The two rows of stitches shall be separated from each other) |
- |
|
|
|
4.3.1 ( The outer stitch) |
- |
|
|
|
4.3.1 (stitches/dm) |
- |
|
|
|
4.3.2 (Mouth) |
- |
|
|
|
4.5 and Table 1 i (Capacity) |
- |
|
|
|
5.2 and Table 1 ii a (Dimensions Inside Length) |
- |
|
|
|
5.2 and Table 1 ii b (Dimensions Inside Width) |
- |
|
|
|
5.2 and Table 1 iii (Ends per dm ) |
- |
|
|
|
5.2 and Table 1 iv (Picks per dm ) |
- |
|
|
|
5.1 and Table 1 v a (Mass of unlaminated sack
IS 1964) |
- |
|
|
|
5.1 and Table 1 v b (Mass of unlaminated sack with liner
) |
- |
|
|
|
5.2 and Table 1 vi a (Average breaking strength of fabric Lengthwise
IS 1969 (Part 1)) |
- |
|
|
|
5.2 and Table 1 vi b (Average breaking strength of fabric Widthwise
IS 1969 (Part 1)) |
- |
|
|
|
5.2 and Table 1 vi (Breaking strength of bottom seam
IS 9030
) |
- |
|
|
|
5.2 and Table 1 viii a (Elongation at break of fabric Lengthwise
IS 1969 (Part 1)) |
- |
|
|
|
5.2 and Table 1 viii b (Elongation at break of fabric Widthwise
IS 1969 (Part 1)) |
- |
|
|
|
|
- |
- except UV resistance test |
10061 |
BIS, Central Laboratory (CL)
| None
| IS 2082 (2018) |
Stationary storage type electric water heaters - Specification (Fifth Revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (Classification ) |
- |
|
|
|
6 (Classification ) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
(Cl.8 of IS 302-2-21:2011) (Protection Against Access to Live Parts) |
- |
|
|
|
(Cl.10 of IS 302-2-21: 2011) (Power Input & Current) |
- |
|
|
|
(Cl.11 of 302-2-21:2011) (Heating) |
- |
|
|
|
(Cl.11 of 302-2-21:2011) (Heating) |
- |
|
|
|
(Cl.13 of IS 302-2-21:2011) (Leakage Current ) |
- |
|
|
|
(Cl.13 of IS 302-2-21:2011) (Electrical Strength at Operating Temperature) |
- |
|
|
|
(Cl.15 of IS 302-2-21-2011) (Moisture Resistance) |
- |
|
|
|
(Cl.15 of IS 302-2-21-2011) (Moisture Resistance) |
- |
|
|
|
(Cl.15 of IS 302-2-21-2011) (Moisture Resistance) |
- |
|
|
|
(Cl.19 of IS 302-2-21:2011) (Abnormal Operation) |
- |
|
|
|
(Cl.19 of IS 302-2-21:2011) (Abnormal Operation) |
- |
|
|
|
(Cl.19 of IS 302-2-21:2011) (Abnormal Operation) |
- |
|
|
|
(Cl.19 of IS 302-2-21:2011) (Abnormal Operation) |
- |
|
|
|
(Cl.20 of IS 302-2-21:2011) (Stability & Mechanical Hazards) |
- |
|
|
|
(Cl.21ofIS302-2-21:2011) (Mechanical strength) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl. 23 of IS 302-2-21: 2011) (Internal Wiring
) |
- |
|
|
|
(Cl. 23 of IS 302-2-21: 2011) (Internal Wiring
) |
- |
|
|
|
(Cl. 23 of IS 302-2-21: 2011) (Internal Wiring
) |
- |
|
|
|
(Cl. 23 of IS 302-2-21: 2011) (Internal Wiring
) |
- |
|
|
|
(Cl. 23 of IS 302-2-21: 2011) (Internal Wiring
) |
- |
|
|
|
(Cl. 23 of IS 302-2-21: 2011) (Internal Wiring
) |
- |
|
|
|
(Cl.24ofIS302-221:2011) (Component) |
- |
|
|
|
(Cl.24ofIS302-221:2011) (Component) |
- |
|
|
|
(Cl.24ofIS302-221:2011) (Component) |
- |
|
|
|
(Cl.24ofIS302-221:2011) (Component) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.26 of IS 302-2-21: 2011) (Terminals for External Conductors) |
- |
|
|
|
(Cl.26 of IS 302-2-21: 2011) (Terminals for External Conductors) |
- |
|
|
|
(Cl.26 of IS 302-2-21: 2011) (Terminals for External Conductors) |
- |
|
|
|
(Cl.26 of IS 302-2-21: 2011) (Terminals for External Conductors) |
- |
|
|
|
(Cl.26 of IS 302-2-21: 2011) (Terminals for External Conductors) |
- |
|
|
|
(Cl.27 of IS 302-2-21:2011) (Provision for Earthing) |
- |
|
|
|
(Cl.27 of IS 302-2-21:2011) (Provision for Earthing) |
- |
|
|
|
(Cl.27 of IS 302-2-21:2011) (Provision for Earthing) |
- |
|
|
|
(Cl.27 of IS 302-2-21:2011) (Provision for Earthing) |
- |
|
|
|
(Cl.28 of IS 302-2-21:2011) (Screws & Connections) |
- |
|
|
|
(Cl.29ofIS302-2-21:2011) (Clearances, Creepage Distances and Solid Insulation) |
- |
|
|
|
(Cl.30 of IS 302-2-21:2011) (Resistance to Heat & Fire) |
- |
|
|
|
(Cl.31 of IS 302-2-21:2011) (Resistance to Rusting) |
- |
|
|
|
(Cl.15 of IS 2082:2018) (Verification of the Rated Capacity) |
- |
|
|
|
(Cl.16 of IS 2082:2018) (Standing Loss per 24 Hours) |
- |
|
|
|
(Cl.17 of IS 2082:2018) (Hot Water Output) |
- |
|
|
|
(Cl.18 of IS 2082:2018) ( Reheating Time) |
- |
|
|
|
(Cl.19 of IS 2082:2018) (Mixing Factor) |
- |
|
|
|
(Cl.20 of IS 2082:2018) (Deviation of Dial Calibration) |
- |
|
|
|
(Cl.21 of IS 2082:2018) (Cyclic Temperature Variation) |
- |
|
|
|
(Cl.22 of IS 2082:2018) (Finish) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
Cl.22.108 of
IS 302-2-21:2018 (Construction : fixing to wall ) |
- |
|
|
|
Cl.22.6 of
IS 302-2-21:2018 (Construction : Size of drain hole ) |
- |
|
|
|
Cl.22.47 of
IS 302-2-21:2018 (Construction : Water pressure test ) |
- |
|
|
|
Cl.22.101 of
IS 302-2-21:2018 (Construction : rated pressure of closed water heater ) |
- |
|
|
|
Cl.22.47 of
IS 302-2-21:2018 (Construction : Water pressure test ) |
- |
|
|
|
Cl.22.101 of
IS 302-2-21:2018 (Construction : rated pressure of closed water heater ) |
- |
|
|
|
Cl.22.103 of
IS 302-2-21:2018 (Construction : Operation of Pressure relieve devices ) |
- |
|
|
|
Cl.22.104 of
IS 302-2-21:2018 (Construction : Outlet of open outlet heater ) |
- |
|
|
|
Cl.22.109 of
IS 302-2-21:2018 (Construction : Drain for appliance having a capacity of more than 15 liter) |
- |
|
|
|
Cl.22.101 of
IS 302-2-21:2018 (Construction : rated pressure of closed water heater ) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
|
- |
- Complete except electronic circuit type appliances(IS 302-2-21, Cl.19.11 of IS 302-1) |
10062 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 14252 (2015) |
Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sack for filling sand – Specification (second revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.3 (Tying Cord) |
- |
|
|
|
3.4.1 (Seam) |
- |
|
|
|
4.1 and Table 1 i a (Dimensions Outside Length) |
- |
|
|
|
4.1 and Table 1 i b (Dimensions Outside Width) |
- |
|
|
|
4.1 and Table 1 ii (Ends per dm ) |
- |
|
|
|
4.1 and Table 1 iii (Picks per dm ) |
- |
|
|
|
4.2 and Table 1 iv (Mass of sack
) |
- |
|
|
|
4.1 and Table 1 v a (Average breaking strength of fabric Warpway
) |
- |
|
|
|
4.1 and Table 1 v b (Average breaking strength of fabric Weftway
) |
- |
|
|
|
4.1 and Table 1 vi (Average Breaking strength of bottom seam ) |
- |
|
|
|
|
- |
- Facility not available for UV resistance, |
10063 |
BIS, Central Laboratory (CL)
| None
| IS 3196 : Part 4 (2001) |
Welded low carbon steel cylinders exceeding 5 litre water capacity for low pressure liquefiable gases - Specification: Part 4 cylinders for toxic and corrosive gases |
- |
- View breakup
Rs. 14350/- for 3 Pc. Cylinder Rs. 10650/- for 2 Pc. Cylinder. (Excluding Radiographic Test) Material testing charges as per relevant referred ISs to be levied additionally
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
14 (Water Capacity) |
- |
|
|
|
15 (Hydrostatic test) |
- |
|
|
|
16 (Pneumatic Leakage Test) |
- |
|
|
|
17.2 (Bursting test) |
- |
|
|
|
18.1.3 (Face Bend Test,) |
- |
|
|
|
18.1.6 (Nicked bend test) |
- |
|
|
|
18.1.7 (Macro Examination) |
- |
|
|
|
8.4 (Agreed finished Thickness ) |
- |
|
|
|
20 (Colour Identification) |
- |
|
|
|
10.2 (Foot Ring) |
- |
|
|
|
10.2 (Foot ring) |
- |
|
|
|
10.2 (Foot ring) |
- |
|
|
|
9.3 (Valve Protection) |
- |
|
|
|
9.3 (Valve Protection) |
- |
|
|
|
15 (Hydrostatic test) |
- |
|
|
|
|
- |
- Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
Excluding "-; cl. 17 HYDROSTATIC STRETCH Test
Valve Protection (Cl.9.3.1)
Bung thread (Cl. 10.3)
*Pneumatic test (Cl 16)
Radiographic Examination (Cl 13)" |
10064 |
BIS, Central Laboratory (CL)
| None
| IS 13095 (1991) |
Butterfly valves for general purposes |
- |
Rs3300/-t View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (VALVE END CONNECTIONS) |
- |
|
|
|
5 (SERVICE APPLICATIONS) |
- |
|
|
|
6 ( NOMINAL SIZES ) |
- |
|
|
|
7 (NOMINAL PRESSURES) |
- |
|
|
|
7.2 (Class designations) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
- Integral Grey Cast Iron Flanges- IS 6418 (Table 2/3/6/7/10)-
Flange-D) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
- Integral Grey Cast Iron Flanges-IS 6418 (Table 2/3/6/7/10)-
Flange-b) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
- Integral Grey Cast Iron Flanges-IS 6418 (Table 2/3/6/7/10)-
Rasied Face-d4) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
- Integral Grey Cast Iron Flanges-IS 6418 (Table 2/3/6/7/10)-
Rasied Face-f) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
- Integral Grey Cast Iron Flanges- IS 6418 (Table 2/3/6/7/10)-
Bolting ) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
- Integral Grey Cast Iron Flanges- IS 6418 (Table 2/3/6/7/10)-
Drilling -Nos. ) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
- Integral Grey Cast Iron Flanges- IS 6418 (Table 2/3/6/7/10)-
Drilling -d2) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
- Integral Grey Cast Iron Flanges- IS 6418 (Table 2/3/6/7/10)-
Drilling -k) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
- Integral Grey Cast Iron Flanges- IS 6418 (Table 2/3/6/7/10)-
Neck -d3) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
- Integral Grey Cast Iron Flanges- IS 6418 (Table 2/3/6/7/10)-
Neck- r) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Malleable Cast Iron Integral Flanges- IS 6418 (Table 4/8/11)-
Flange-D) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Malleable Cast Iron Integral Flanges- IS 6418 (Table 4/8/11)-
Flange-b) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Malleable Cast Iron Integral Flanges- IS 6418 (Table 4/8/11)-
Rasied Face-d4) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Malleable Cast Iron Integral Flanges- IS 6418 (Table 4/8/11)-
Rasied Face-f) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Malleable Cast Iron Integral Flanges- IS 6418 (Table 4/8/11)-
Bolting) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Malleable Cast Iron Integral Flanges- IS 6418 (Table 4/8/11)-
Drilling -Nos. ) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Malleable Cast Iron Integral Flanges- IS 6418 (Table 4/8/11)-
Drilling -d2 ) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Malleable Cast Iron Integral Flanges- IS 6418 (Table 4/8/11)-
Drilling -k) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Malleable Cast Iron Integral Flanges- IS 6418 (Table 4/8/11)-
Neck -d3) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Malleable Cast Iron Integral Flanges- IS 6418 (Table 4/8/11)-
Neck-r) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Steel Plate Flanges for Welding- IS 6392 (Table 3/5/11/17/23/28)-
Pipe O.D.- d1) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Steel Plate Flanges for Welding- IS 6392 (Table 3/5/11/17/23/28)-
Flange - D) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Steel Plate Flanges for Welding- IS 6392 (Table 3/5/11/17/23/28)-
Flange - b) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Steel Plate Flanges for Welding- IS 6392 (Table 3/5/11/17/23/28)-
Raised Face - d4) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Steel Plate Flanges for Welding- IS 6392 (Table 3/5/11/17/23/28)-
Raised Face - f) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Steel Plate Flanges for Welding- IS 6392 (Table 3/5/11/17/23/28)-
Bolting) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Steel Plate Flanges for Welding- IS 6392 (Table 3/5/11/17/23/28)-
Drilling - Nos.) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Steel Plate Flanges for Welding- IS 6392 (Table 3/5/11/17/23/28)-
Drilling -d2) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Steel Plate Flanges for Welding- IS 6392 (Table 3/5/11/17/23/28)-
Drilling -k) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Integral Steel Flanges- IS 6392 (Table 15/21/26)-
Flange -D) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Integral Steel Flanges- IS 6392 (Table 15/21/26)-
Flange - b) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Integral Steel Flanges- IS 6392 (Table 15/21/26)-
Raised Face - d4) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Integral Steel Flanges- IS 6392 (Table 15/21/26)-
Raised Face - f) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Integral Steel Flanges- IS 6392 (Table 15/21/26)-
Bolting) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Integral Steel Flanges- IS 6392 (Table 15/21/26)-
Drilling - Nos.) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Integral Steel Flanges- IS 6392 (Table 15/21/26)-
Drilling -d2) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Steel Plate Flanges for Welding- IS 6392 (Table 3/5/11/17/23/28)-
Drilling -k) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Integral Steel Flanges- IS 6392 (Table 15/21/26)-
Flange -D) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Integral Steel Flanges- IS 6392 (Table 15/21/26)-
Flange - b) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Integral Steel Flanges- IS 6392 (Table 15/21/26)-
Raised Face - d4) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Integral Steel Flanges- IS 6392 (Table 15/21/26)-
Raised Face - f) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Integral Steel Flanges- IS 6392 (Table 15/21/26)-
Bolting) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Integral Steel Flanges- IS 6392 (Table 15/21/26)-
Drilling - Nos.) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Integral Steel Flanges- IS 6392 (Table 15/21/26)-
Drilling -d2) |
- |
|
|
|
9-Annex B (BODY ENDS ( Double Flanged Body Ends/Wafer Body Ends)
-Integral Steel Flanges- IS 6392 (Table 15/21/26)-
Drilling -k) |
- |
|
|
|
9.1.1 ( Double Flanged Body Ends) |
- |
|
|
|
9.2.2 (Wafer Body Ends) |
- |
|
|
|
10.1 -Table1 (FACE TO FACE DIMENSIONS) |
- |
|
|
|
11 (Bodies) |
- |
|
|
|
12 (DISC AND SHAFT) |
- |
|
|
|
13 (SEATING AND LININGS) |
- |
|
|
|
16 (OPERATION) |
- |
|
|
|
17.1 (Performance Testing) |
- |
|
|
|
17.2 (Body Test) |
- |
|
|
|
17.3 (Seat Test) |
- |
|
|
|
17.4 (Disc Strength Test) |
- |
|
|
|
|
- |
- Excluding -; hydraulic shock. |
10065 |
BIS, Central Laboratory (CL)
| None
| IS 1554 : Part 2 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 2 for working voltages from 3.3 kV up to and including 11 kV (Second Revision) |
- |
- View breakup
Rs. 29850/- for single core Excluding Partial discharge test, bending test followed by partial discharge test, Heating cycle test followed by partial discharge test, impulse withstand test. For multi core cables, extra charges @ 35 % for each additional core shall be levied Material testing charges as per relevant referred ISs to be levied additionally
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1 (CONDUCTOR) |
- |
|
|
|
3.1.1 (CONDUCTOR) |
- |
|
|
|
4.1 (INSULATION) |
- |
|
|
|
5.1 (SCREENING) |
- |
|
|
|
6.1 (FILLERS AND INNER SHEATH) |
- |
|
|
|
6.2 (FILLERS AND INNER SHEATH) |
- |
|
|
|
7.1 (ARMOURING) |
- |
|
|
|
8.1 (OUTER SHEATH) |
- |
|
|
|
9.1 (CONDUCTOR) |
- |
|
|
|
9.2 (CONDUCTOR) |
- |
|
|
|
10.1 (CONDUCTOR SCREENING) |
- |
|
|
|
11.1 (INSULATION) |
- |
|
|
|
11.2 (INSULATION : Thickness of Insulation) |
- |
|
|
|
11.3 (INSULATION : Tolerance on Thickness of Insulation) |
- |
|
|
|
11.4 (INSULATION : Application of Insulation) |
- |
|
|
|
12.1 (INSULATION SCREENING) |
- |
|
|
|
13.1 (CORE IDENTIFICATION) |
- |
|
|
|
14.1 (LAYING UP OF CORES) |
- |
|
|
|
15.1 (INNER SHEATH (COMMON COVERING)) |
- |
|
|
|
15.2 (INNER SHEATH (COMMON COVERING)) |
- |
|
|
|
15.3 (INNER SHEATH (COMMON COVERING)) |
- |
|
|
|
15.4 (INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
|
|
|
16.1.1 (ARMOURING : Application) |
- |
|
|
|
16.1.2 (ARMOURING : Application) |
- |
|
|
|
16.1.3 (ARMOURING : Direction of lay ) |
- |
|
|
|
16.1.4 (ARMOURING : Application) |
- |
|
|
|
16.2.1 (ARMOURING : Type of Armour) |
- |
|
|
|
16.2.2 (ARMOURING : Type of Armour) |
- |
|
|
|
16.3 (Armouring : Dimensions -Wire Diameter) |
- |
|
|
|
16.3 (Armouring : Dimensions -Formed wire ) |
- |
|
|
|
16.4 (ARMOURING : Joints) |
- |
|
|
|
16.5 (ARMOURING : Resistance) |
- |
|
|
|
13.6 a) (ARMOURING: Tensile Strength) |
- |
|
|
|
13.6 b) (ARMOURING: Elongation ) |
- |
|
|
|
13.6 c) (ARMOURING: Torsion Test (For round wire ) ) |
- |
|
|
|
13.6 d) (ARMOURING: Winding Test(For formed wire)) |
- |
|
|
|
13.6 e) (ARMOURING: Uniformity of zinc coating) |
- |
|
|
|
13.6 f) (ARMOURING: Mass of zinc coating ) |
- |
|
|
|
13.6 g) (ARMOURING: Resistivity) |
- |
|
|
|
17.1 (OUTER SHEATH) |
- |
|
|
|
17.2 (OUTER SHEATH : colour ) |
- |
|
|
|
17.3.1 (Thickness of Outer Sheath : Unarmoured Cables) |
- |
|
|
|
17.3.2 (Thickness of Outer Sheath : Armoured Cables) |
- |
|
|
|
18.1 a) 1) (Tests on Conductor : Annealing test (for copper)) |
- |
|
|
|
18.1 a) 2) (Tensile test (for aluminium) - Before stranding ) |
- |
|
|
|
18.1 a) 2) (Tensile test (for aluminium) - After stranding ) |
- |
|
|
|
18.1 a) 3) (Tests on Conductor : Wrapping test ( for aluminium)) |
- |
|
|
|
18.1 a)4) (Tests on conductor : Conductor resistance test - Main conductor ) |
- |
|
|
|
18.1 a)4) (Resistance test - Neutral conductor ) |
- |
|
|
|
18.1 d) 1) (Phyaical tests for insulation : Tensile Test) |
- |
|
|
|
18.1 d) 1) (Phyaical tests for insulation : Elongation ) |
- |
|
|
|
18.1 d) 2) (Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
|
|
|
18.1 d) 2) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
|
|
|
18.1 d) 2) (Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
|
|
|
18.1 d) 2) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
|
|
|
18.1 d) 1) (Physical tests for sheath : Tensile stregth ) |
- |
|
|
|
18.1 d) 1) (Physical tests for sheath : Elongation ) |
- |
|
|
|
18.1 d) 2) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
|
|
|
18.1 d) 2) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
|
|
|
18.1 d) 2) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
|
|
|
18.1 d) 2) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
|
|
|
18.1 d) 3) (Phyaical tests for insulation : Shrinkage ) |
- |
|
|
|
18.1 d) 3) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
|
|
|
18.1 d) 3) (Phyaical tests for Sheath : Shrinkage ) |
- |
|
|
|
18.1 d) 3) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
|
|
|
18.1 d) 4) (Hot deformation : Insulation ) |
- |
|
|
|
18.1 d) 4) (Hot deformation : Sheath ) |
- |
|
|
|
18.1 d) 5) ( Loss of mass in air oven- Insulation ) |
- |
|
|
|
18.1 d) 5) ( Loss of mass in air oven- sheath ) |
- |
|
|
|
18.1 d) 6) (Heat shock test- Insulation ) |
- |
|
|
|
18.1 d) 6) (Heat shock test- sheath ) |
- |
|
|
|
18.1 d) 7) (Thermal stability- insulation ) |
- |
|
|
|
18.1 d) 7) (Thermal stability- Sheath ) |
- |
|
|
|
18.1 e) (Insulation resistance test : Volume Resistivity ) |
- |
|
|
|
18.1 e) (Insulation resistance test : IR Constant ) |
- |
|
|
|
19.7 (High voltage test) |
- |
|
|
|
19.8 (Flammability test) |
- |
|
|
|
Cl. 18.1 d) 8) (Water absorption Test (Gravimetric)) |
- |
|
|
|
Cl.20.1 (Manufacturer's Identification) |
- |
|
|
|
Cl.20.2 (Cable Identification) |
- |
|
|
|
Cl.20.3 (Cable Code) |
- |
|
|
|
Cl.21.1 (Packing & Marking) |
- |
|
|
|
Cl.21.2 (Packing & Marking) |
- |
|
|
|
Cl.21.2.1 (Packing & Marking) |
- |
|
|
|
|
- |
- Excluding1. Category C1/ C2 & 2. Partial discharge test 3. Bending test 4. Dielectric power factor test: a) As a function of voltage b) As a function of temperature5. Heat cycle test 6. Impulse withstand test 7.High voltage test |
10066 |
BIS, Central Laboratory (CL)
| None
| IS 1536 (2001) |
Centrifugally cast (Spun) iron pressure pipes for water, gas and sewage - Specification (Fourth Revision) |
- |
Rs.4500.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
11.2, annex-A (Tensile Test ( for pipes over 300mm)) |
- |
|
|
|
11.3 (Brinell Hardness Test) |
- |
|
|
|
12.1 (Hydrostatic Test) |
- |
|
|
|
13.3
Table 3 (DE) |
- |
|
|
|
13.3
Table 3 (DI) |
- |
|
|
|
13.3
Table 3 (p) |
- |
|
|
|
13.3
Table 3 (g) |
- |
|
|
|
13.3
Table 3 (h) |
- |
|
|
|
13.3
Table 3 (a(optional)) |
- |
|
|
|
13.3
Table 3 (K) |
- |
|
|
|
13.3
Table 3 (L) |
- |
|
|
|
13.3
Table 3 (M) |
- |
|
|
|
13.3
Table 3 (N) |
- |
|
|
|
13.3
Table 3 (f) |
- |
|
|
|
13.3
Table 4 (DE) |
- |
|
|
|
13.3
Table 4 (X) |
- |
|
|
|
13.3
Table 4 (DI) |
- |
|
|
|
13.3
Table 4 (P) |
- |
|
|
|
13.3
Table 4 (Q) |
- |
|
|
|
13.3
Table 4 (I) |
- |
|
|
|
13.3
Table 4 (J) |
- |
|
|
|
13.3
Table 4 (K) |
- |
|
|
|
13.3
Table 4 (N) |
- |
|
|
|
13.3
Table 4 (O) |
- |
|
|
|
13.3
Table 4 (S) |
- |
|
|
|
13.3
Table 4 (T) |
- |
|
|
|
13.3
Table 4 (L) |
- |
|
|
|
13.3
Table 4 (M) |
- |
|
|
|
13.4
Table 5 (c) |
- |
|
|
|
13.4
Table 5 (D) |
- |
|
|
|
13.4
Table 5 (E) |
- |
|
|
|
13.4
Table 5 (b) |
- |
|
|
|
13.4
Table 5 (a) |
- |
|
|
|
13.4
Table 5 (r) |
- |
|
|
|
13.4
Table 5 (f) |
- |
|
|
|
13.4
Table 5 (s) |
- |
|
|
|
13.4
Table 5 (Holes Number) |
- |
|
|
|
13.4
Table 5 (Holes Diameter) |
- |
|
|
|
13.4
Table 5 (Diameter of Bolts) |
- |
|
|
|
13.5
Table 6 to 8 (DE Lead joint) |
- |
|
|
|
13.5
Table 6 to 8 (DE Push on joint) |
- |
|
|
|
13.5
Table 6 to 8 (e) |
- |
|
|
|
13.6
Table 9 (DE) |
- |
|
|
|
|
- |
- Since the composition of cast iron shall be left to the discretion ofthe manufacturer , as such element to be tested with specified requirement and tolerances if any may please be declared with method of testing. Sample Size 5 pcs of 5x5 cm having dia> 3mm and thickness > 0.8 mm.;
Excluding -; Cl 11.2 - Ring Test, Cl 12 - Hydrostatic Test |
10067 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 1038 (1983) |
Specification For Steel Doors, Windows And Ventilators |
- |
- View breakup
Hence complete testing charges for the product are Rs.3000.00
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1. (Size-Height) |
- |
|
|
|
4.1 (Size-Width) |
- |
|
|
|
4.3 (Designation) |
- |
|
|
|
5 (Material-Rolled Steel Section) |
- |
|
|
|
5 (Material-Coupling Section) |
- |
|
|
|
5 (Material-Glass Panels) |
- |
|
|
|
5 (Material-Screws) |
- |
|
|
|
6.1.1.1 (Visual Inspection Test) |
- |
|
|
|
6.1.1.1 (Visual Inspection Test) |
- |
|
|
|
6.1.1.1 (Visual Inspection Test) |
- |
|
|
|
6.1.1.2 (Macro Examination) |
- |
|
|
|
6.1.1.4 (Fillet Weld Test) |
- |
|
|
|
6.2 (Side Hung Shutter) |
- |
|
|
|
6.2 (Side Hung Shutter) |
- |
|
|
|
6.2 (Side Hung Shutter- Thickness of hinge) |
- |
|
|
|
6.2 (Side Hung Shutter- Pin diameter) |
- |
|
|
|
6.3 (Top Hung Ventilator-Width of hinge) |
- |
|
|
|
6.2.2 & 6.2.2.1 (Handle and Handle Plate-Material of handel ) |
- |
|
|
|
6.2.2 & 6.2.2.1 (Handle and Handle Plate- Thicknesss of handle) |
- |
|
|
|
6.2.2 & 6.2.2.1 (Handle and Handle Plate-Material of handel plate) |
- |
|
|
|
6.2.2 & 6.2.2.1 (Handle and Handle Plate) |
- |
|
|
|
6.2.2 & 6.2.2.1 (Handle and Handle Plate) |
- |
|
|
|
6.2.2 & 6.2.2.1 (Handle and Handle Plate-Height of handle plate) |
- |
|
|
|
6.2.3 (Peg Stay - Material) |
- |
|
|
|
6.2.3 (Peg Stay - Thickness) |
- |
|
|
|
6.2.3 (Peg Stay ) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-A) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-B) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-C) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-D) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-E) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-F) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-G) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-H) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-J) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-K) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-L) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-M) |
- |
|
|
|
6.3 (Top Hung Ventilator) |
- |
|
|
|
6.3 (Top Hung Ventilator) |
- |
|
|
|
6.3 (Top Hung Ventilator-Thickness of hinge) |
- |
|
|
|
6.3 (Top Hung Ventilator-Pin diameter) |
- |
|
|
|
6.3 (Top Hung Ventilator-Width of hinge) |
- |
|
|
|
7.1 (Position of Holes) |
- |
|
|
|
7.2 Table 2 (Position of Fixing Screws) |
- |
|
|
|
7.2 Table 2 (Lugs-A) |
- |
|
|
|
7.2 Table 2 (Lugs-B) |
- |
|
|
|
7.2 Table 2 (Lugs-C) |
- |
|
|
|
7.2 Table 2 (Lugs-D) |
- |
|
|
|
7.2 Table 2 (Lugs-E) |
- |
|
|
|
7.2 Table 2 (Lugs-F) |
- |
|
|
|
7.2 Table 2 (Lugs-G) |
- |
|
|
|
8 (Finish) |
- |
|
|
|
9 (Glazing) |
- |
|
|
|
9 (Glazing- No of glazing clip against each plate) |
- |
|
|
|
|
- |
- Chem: except V,Al,Nb,Ti |
10068 |
BIS, Central Laboratory (CL)
| None
| IS 4250 (1980) |
Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) |
- |
- View breakup
Rs 9750/- Excluding Endurance test for juicers
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (Classification- IS 302-1 ) |
- |
|
|
|
6 (Classification- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.2 (Marking) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.4 (Marking) |
- |
|
|
|
7.5 (Marking) |
- |
|
|
|
7.6 (Marking) |
- |
|
|
|
8 ( Protection Against Electric Shock, IS 302-1) |
- |
|
|
|
9 (Starting, IS 302-1) |
- |
|
|
|
10 (Power Input and Current, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
13 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
|
|
|
13 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
|
|
|
15.1 (Moisture Resistance, IS 302-1) |
- |
|
|
|
15.2 (Moisture Resistance-Spillage test) |
- |
|
|
|
15 (Moisture Resistance, IS 302-1) |
- |
|
|
|
16 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
|
|
|
16 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
20 (Stability & Mechanical Hazards, IS 302-1) |
- |
|
|
|
20 (Stability & Mechanical Hazards, IS 302-1) |
- |
|
|
|
21 (Mechanical Strength, IS 302-1) |
- |
|
|
|
20 (Stability & Mechanical Hazards, IS 302-1) |
- |
|
|
|
21 (Mechanical Strength, IS 302-1) |
- |
|
|
|
21 (Mechanical Strength, IS 302-1) |
- |
|
|
|
22.1 (Construction, IS 302-1) |
- |
|
|
|
22.2 (Construction) |
- |
|
|
|
22.3 (Construction) |
- |
|
|
|
22.4 (Construction) |
- |
|
|
|
22.5 (Construction) |
- |
|
|
|
22.8 (Construction) |
- |
|
|
|
22.9 (Construction) |
- |
|
|
|
22.1 (Construction) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.2 (Components) |
- |
|
|
|
24.5 (Components) |
- |
|
|
|
24.6 (Components) |
- |
|
|
|
24.7 (Components) |
- |
|
|
|
24.8 (Components) |
- |
|
|
|
24.9 (Components) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
26 (Terminals for External Conductors, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
28 (Screws & Connections, IS 302-1) |
- |
|
|
|
29 (Clearances and Distances through Insulation, IS 302-1) |
- |
|
|
|
29 (Clearances and Distances through Insulation, IS 302-1) |
- |
|
|
|
30 (Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
|
|
|
31 (Resistance of Rusting, IS 302-1) |
- |
|
|
|
34.2 (Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
|
|
|
34.2 (Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
|
|
|
34.2 (Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
|
|
|
34.3 (Whisking egg whites ) |
- |
|
|
|
34.4 (IDLI batter-Grinding of black gram) |
- |
|
|
|
34.4 (IDLI batter-Grinding of rice) |
- |
|
|
|
34.4 (IDLI batter-Grinding of rice) |
- |
|
|
|
34.4 (IDLI batter-Grinding of rice) |
- |
|
|
|
34.5.1 (a) (Operational test for juicers ) |
- |
|
|
|
34.5.1 (b) (Operational test for juicers ) |
- |
|
|
|
34.5.2 (Operational test for juicers ) |
- |
|
|
|
35 (Temperature withstand test for bowl) |
- |
|
|
|
36 (Test for controls ) |
- |
|
|
|
37 (Strength of Assembly ) |
- |
|
|
|
37 (Strength of Assembly ) |
- |
|
|
|
|
- |
- Excluding electronic circuit type appliances(Cl.19.11 of IS 302 part 1 |
10069 |
BIS, Central Laboratory (CL)
| None
| IS 362 (1991) |
Parliament Hinges -specification |
- |
- View breakup
Rs.2250/- and material testing charges as per relevant referred Iss
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 7.1 (Brass parliament hinges shall have either bright or satin finish and shall be suitably protected against discoloration) |
- |
|
|
|
Cl. 7.2 (Ref. Cl. 11.1 of IS 1868:1996) ( appearance and Colour - shall be free from visible defects on the significant surface(s) when viewed from an agreed distance) |
- |
|
|
|
Cl. 7.3 (Mild steel parliament hinges shall be finished bright or electro-galvanized as specified by the purchaser) |
- |
|
|
|
5.1-able 2 (Dlmenslons for Aluminium Alloy Parliament Hinges-A) |
- |
|
|
|
5.1-able 2 (Dlmenslons for Aluminium Alloy Parliament Hinges-B) |
- |
|
|
|
5.1-able 2 (Dlmenslons for Aluminium Alloy Parliament Hinges-C) |
- |
|
|
|
5.1-able 2 (Dlmenslons for Aluminium Alloy Parliament Hinges-D) |
- |
|
|
|
5.1-able 2 (Dlmenslons for Aluminium Alloy Parliament Hinges-d) |
- |
|
|
|
5.1-able 2 (Dlmenslons for Aluminium Alloy Parliament Hinges-E) |
- |
|
|
|
5.1-able 2 (Dlmenslons for Aluminium Alloy Parliament Hinges-Thickness of Flap) |
- |
|
|
|
5.1-able 2 (Dlmenslons for Aluminium Alloy Parliament Hinges-No. of Screw holes) |
- |
|
|
|
5.1-able 2 (Dlmenslons for Aluminium Alloy Parliament Hinges-Holes for screw designation) |
- |
|
|
|
6.1 (MANUFACTURE-General) |
- |
|
|
|
6.2 (MANUFACTURE-Knuckles) |
- |
|
|
|
6.3 (MANUFACTURE-Pins) |
- |
|
|
|
6.4 (MANUFACTURE-Screw Holes) |
- |
|
|
|
6.5 (MANUFACTURE-Position of Holes) |
- |
|
|
|
6.5 (MANUFACTURE-Position of Holes-minimum distance from
the ends of the flap) |
- |
|
|
|
6.5 (MANUFACTURE-Position of Holes-minimum distance from
the inner edge) |
- |
|
|
|
6.5 (MANUFACTURE-Position of Holes-minimum distance from
the ends of the flap) |
- |
|
|
|
6.5 (MANUFACTURE-Position of Holes-minimum distance from
the inner edge) |
- |
|
|
|
6.5 (MANUFACTURE-Position of Holes) |
- |
|
|
|
7.3 (FINISH) |
- |
|
|
|
|
- |
- Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
Excluding "Complete for material; Quality of Sealing (Cl 10), Resistance to Crazing by Deformation (Cl 14)
Fastness to Light Cl 15
Light reflection properties Cl 16
Electrical Breakdown potential (Cl 17)
Continuity of the anodize coating (Cl 18)" |
10070 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 10748 (2004) |
Hot - Rolled steel strip for welded tubes and pipes - Specification (Second Revision) |
For all grades except tests mentioned in remarks |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 8 & Table 3 (UTM) |
- |
|
|
|
Cl 9 (Press) |
- |
|
|
|
Cl 11 (Workmanship) |
- |
|
|
|
Cl 12 & 13 (Length, Width & Thickness) |
- |
|
|
|
7.1 (Carbon %) |
- |
|
|
|
7.1 (Manganese %) |
- |
|
|
|
7.1 (Phosphorus %) |
- |
|
|
|
7.1 (Sulphur %) |
- |
|
|
|
7.1 (Silicon %) |
- |
|
|
|
7.1 ( Copper %) |
- |
|
|
|
7.1 ( Nitrogen%) |
- |
|
|
|
7.1 ( Nitrogen%) |
- |
|
|
|
7.1 ( Aluminium %) |
- |
|
|
|
7.1 ( Ti) |
- |
|
|
|
7.1 (CE) |
- |
|
|
|
|
- |
- Chem: Facility not available for V, W, O, Sn, B |
10071 |
BIS, Central Laboratory (CL)
| None
| IS 13997 (2014) |
Drums, large open top - Specification (First Revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5, Table 1 (Dimensions-D2) |
- |
|
|
|
5, Table 1 (Dimensions-D3) |
- |
|
|
|
5, Table 1 (Dimensions-D4) |
- |
|
|
|
5, Table 1 (Dimensions-H1) |
- |
|
|
|
5, Table 1 (Dimensions-H5) |
- |
|
|
|
5, Table 1 (Dimensions-h2) |
- |
|
|
|
5, Table 1 (Dimensions-h3) |
- |
|
|
|
5, Table 1 (Dimensions-h4) |
- |
|
|
|
5, Table 1 (Dimensions-p1) |
- |
|
|
|
6.2 (The nominal thickness of steel sheets for body
and ends ) |
- |
|
|
|
7.1 ( CONSTRUCTION) |
- |
|
|
|
7.1 ( CONSTRUCTION) |
- |
|
|
|
7.2 ( CONSTRUCTION) |
- |
|
|
|
7.3 ( CONSTRUCTION- Double Seam/Spiral Seam/Triple Seam Construction for Grade A Drums) |
- |
|
|
|
7.4 ( CONSTRUCTION-Spiral Seam/Triple Seam Construction for Grade B Drums) |
- |
|
|
|
7.4 ( CONSTRUCTION-Spiral Seam/Triple Seam Construction for Grade B Drums-Seam rolling layers) |
- |
|
|
|
7.4 ( CONSTRUCTION-Spiral Seam/Triple Seam Construction for Grade B Drums-Seam rolling layers) |
- |
|
|
|
7.5 ( CONSTRUCTION) |
- |
|
|
|
7.6 ( CONSTRUCTION) |
- |
|
|
|
7.7 ( CONSTRUCTION) |
- |
|
|
|
7.8 ( CONSTRUCTION) |
- |
|
|
|
7.8 ( CONSTRUCTION- crest to trough gap) |
- |
|
|
|
7.8 ( CONSTRUCTION- no of corrugations on the body Each side) |
- |
|
|
|
7.9 (Closures) |
- |
|
|
|
7.10(a) (Closures) |
- |
|
|
|
7.10(b) (Closures) |
- |
|
|
|
7.10(c) (Closures) |
- |
|
|
|
7.10(d) (Closures) |
- |
|
|
|
7.11 ( Locking Ring) |
- |
|
|
|
8.1 (FINISH
) |
- |
|
|
|
8.2 (FINISH
) |
- |
|
|
|
9 (leakage test) |
- |
|
|
|
|
- |
- - |
10072 |
BIS, Central Laboratory (CL)
| None
| IS 12664 : Part 1 (2003) |
Artificial limbs - Sach foot for lower extremity prostheses: Part 1 design and dimensions (First Revision) |
- |
Rs.1800.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (Type) |
- |
|
|
|
5,5.1 (Material for Foot) |
- |
|
|
|
5,5.2 (Material for Heel) |
- |
|
|
|
6, 7.3,Table1 ( Length of Foot) |
- |
|
|
|
6, 7.3,Table1 (Toe Circumference) |
- |
|
|
|
6, 7.3,Table1 (Heel Width ( Thread line)) |
- |
|
|
|
6, 7.3,Table1 (Heel Height) |
- |
|
|
|
6, 7.3,Table1 (Foot Height) |
- |
|
|
|
6, 7.3,Table1 (Heel Height) |
- |
|
|
|
7,7.1 (SHAPE & DESIGN; Performance Test) |
- |
|
|
|
7,7.2 (SHAPE & DESIGN Proper Shape) |
- |
|
|
|
7,7.4 (Adoption of Foot) |
- |
|
|
|
8,8.1 (Marking) |
- |
|
|
|
|
- |
- - |
10073 |
BIS, Central Laboratory (CL)
| None
| IS 3196 : Part 2 (2006) |
Welded low carbon steel cylinders exceeding 5 litre water capacity for low pressure liquefiable gases: Part 2 cylinders for liquefiable non - Toxic gases other than lpg - Specification (First Revision) |
- |
- View breakup
Rs. 13300/- for 3 Pc. Cylinder Rs. 9600/- for 2 Pc. Cylinder. (Excluding Radiographic and Fatigue Test ) Material testing charges as per relevant referred ISs to be levied additionally
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
14 (Water Capacity) |
- |
|
|
|
17 (Fatigue test: Fatigue testing/Cycle testing) |
- |
|
|
|
17.3 (Burst test under Hydraulic pressure) |
- |
|
|
|
18 (a)Parent metal Longitudinal specimen) |
- |
|
|
|
18 (a)Parent metal Circumferential specimen) |
- |
|
|
|
18 (c)Weld Joint test specimen) |
- |
|
|
|
18.1.3 (Root Bend test,) |
- |
|
|
|
18.1.3 (Face Bend Test,) |
- |
|
|
|
18.1.4 (Macro Examination Body ,Bung, Non pressure parts Attachments-Foot ring and Stay Plate) |
- |
|
|
|
18.1.5 (Minimum Thickness test) |
- |
|
|
|
20 (Colour Identification) |
- |
|
|
|
10.3 (Bung) |
- |
|
|
|
10 (Foot Ring) |
- |
|
|
|
10 (Foot ring) |
- |
|
|
|
10 (Handle) |
- |
|
|
|
9 (Valve Protection) |
- |
|
|
|
16 (Pneumatic Leakage Test) |
- |
|
|
|
Cl. 4 (Carbon) |
- |
|
|
|
Cl. 4 (Sulphur) |
- |
|
|
|
Cl. 4 (Manganese) |
- |
|
|
|
Cl. 4 (Silicon) |
- |
|
|
|
Cl. 4 (Aluminium) |
- |
|
|
|
Cl. 4 (Niobium) |
- |
|
|
|
Cl. 4 (Titanium) |
- |
|
|
|
Cl. 4 (Vanadium) |
- |
|
|
|
Cl. 4 (Nb+Ti+V) |
- |
|
|
|
Cl. 4 (Nitrogen) |
- |
|
|
|
Cl. 4 (Carbon) |
- |
|
|
|
Cl. 4.2 (Sulphur) |
- |
|
|
|
Cl. 4.2 (Phosphorous) |
- |
|
|
|
Cl. 4.2 (Manganese) |
- |
|
|
|
Cl. 4.2 (Silicon) |
- |
|
|
|
Cl. 4.2 (Aluminium) |
- |
|
|
|
Cl. 4.2 (Nickel) |
- |
|
|
|
Cl. 4.2 (Chromium) |
- |
|
|
|
Cl. 4.2 (Copper) |
- |
|
|
|
Cl. 4.2 (Molybdenum) |
- |
|
|
|
Cl. 4.2 (Vanadium) |
- |
|
|
|
Cl. 4.2 (Boron) |
- |
|
|
|
Cl. 4.2 (Tin) |
- |
|
|
|
Cl. 4.2 (Cr+Ni+Mo) |
- |
|
|
|
Cl. 4.2 (Cu+10x Sn) |
- |
|
|
|
Cl. 4.2 (Carbon Equivalent) |
- |
|
|
|
Cl. 4.2 (Nitrogen) |
- |
|
|
|
Cl. 4.2 (Niobium) |
- |
|
|
|
Cl. 4.2 (Titanium) |
- |
|
|
|
Cl. 4.2 (Vanadium) |
- |
|
|
|
Cl. 4.2 (Nb+Ti+V) |
- |
|
|
|
Cl. 4.2 (Cr+Ni) |
- |
|
|
|
Cl. 4.3 (Carbon) |
- |
|
|
|
Cl. 4.3 (Sulphur) |
- |
|
|
|
Cl. 4.3 (Phosphorous) |
- |
|
|
|
Cl. 4.3 (Manganese) |
- |
|
|
|
Cl. 4.3 (Silicon) |
- |
|
|
|
Cl. 4.3 (Aluminium) |
- |
|
|
|
Cl. 4.3 (Nickel) |
- |
|
|
|
Cl. 4.3 (Chromium) |
- |
|
|
|
Cl. 4.3 (Copper) |
- |
|
|
|
Cl. 4.3 (Molybdenum) |
- |
|
|
|
Cl. 4.3 (Vanadium) |
- |
|
|
|
Cl. 4.3 (Boron) |
- |
|
|
|
Cl. 4.3 (Carbon Equivalent) |
- |
|
|
|
Cl. 4.3 (Nitrogen) |
- |
|
|
|
Cl. 4.3 (Niobium) |
- |
|
|
|
Cl. 4.3 (Titanium) |
- |
|
|
|
Cl. 4.3 (Vanadium) |
- |
|
|
|
Cl. 4.3 (Nb+Ti+V) |
- |
|
|
|
Cl. 4.3 (Cr+Ni) |
- |
|
|
|
Cl. 4.4 (Carbon) |
- |
|
|
|
Cl. 4.4 (Sulphur) |
- |
|
|
|
Cl. 4.4 (Phosphorous) |
- |
|
|
|
Cl. 4.4 (Manganese) |
- |
|
|
|
Cl. 4.4 (Silicon) |
- |
|
|
|
Cl. 4.4 (Aluminium) |
- |
|
|
|
Cl. 4.4 (Nickel) |
- |
|
|
|
Cl. 4.4 (Chromium) |
- |
|
|
|
Cl. 4.4 (Copper) |
- |
|
|
|
Cl. 4.4 (Molybdenum) |
- |
|
|
|
Cl. 4.4 (Vanadium) |
- |
|
|
|
Cl. 4.4 (Boron) |
- |
|
|
|
Cl. 4.4 (Carbon Equivalent) |
- |
|
|
|
Cl. 4.4 (Nitrogen) |
- |
|
|
|
Cl. 4.4 (Niobium) |
- |
|
|
|
Cl. 4.4 (Titanium) |
- |
|
|
|
Cl. 4.4 (Vanadium) |
- |
|
|
|
Cl. 4.4 (Nb+Ti+V) |
- |
|
|
|
Cl. 4.4 (Cr+Ni) |
- |
|
|
|
|
- |
- Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
Excluding "-; HYDROSTATIC STRETCH Test (Cl 17.1)
Fatigue Test (Cl.17.2)
Valves connection (Cl 9.1)
Fitting other than valves (Cl.10) Handle (Cl.10.1)
Bung (Cl 10.3)
13 RADIOGRAPHIC EXAMINATION" |
10074 |
BIS, Central Laboratory (CL)
| None
| IS 12585 (1988) |
Specification for thermoplastic hoses (Textile Reinforced) for water - General purpose |
- |
- View breakup
Rs. 1500/- excluding Loss in mass on heating, Adhesion, Minimum bend radius and Low temperature flexibility.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 3 (Types) |
- |
|
|
|
Cl 4.1 (Construction) |
- |
|
|
|
Cl 4.2 (Dimensions & Tolerances) |
- |
|
|
|
Cl 4.3.3 (Pressure Requirements) |
- |
|
|
|
Cl 4.3.4 (Minimum Bend Radius) |
- |
|
|
|
Cl 4.3.5 (Low Temperature Flexibility) |
- |
|
|
|
|
- |
- - |
10075 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 723 (1972) |
Specification for steel countersunk head wire nails (First Revision) |
All Grades |
- View breakup
Testing Charges for Mechanical testing for the product: Rs. 1950/- Testing charges for Chemical parameters in Table 1 is Rs. 3600/- Additional charge for testing of element apart from Table 1 of IS 7887 (Al, Si etc.) will be Rs. 1000/- extra for each element.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3 Table-1,2,3,4 (Dimensions & Tolerances-Shank Dia) |
- |
|
|
|
3 Table-1,2,3,4 (Dimensions & Tolerances-Head Diameter) |
- |
|
|
|
3 Table-1,2,3,4 (Dimensions & Tolerances-Length) |
- |
|
|
|
3 Table-1,2,3,4 (Approximate no of nails /kg) |
- |
|
|
|
3.1 (Band of Shank) |
- |
|
|
|
3.2 (Eccentricity and ovality of centre of nails from axis of shank) |
- |
|
|
|
5 (General Requirment) |
- |
|
|
|
6 (Finish) |
- |
|
|
|
7.1 (Bend Test) |
- |
|
|
|
2 (Carbon- IS 228(Part 1)) |
- |
|
|
|
2 (Sulphur- IS 228(Part 9)) |
- |
|
|
|
2 (Phosphorous- IS 228(Part 3)) |
- |
|
|
|
2 (Manganese- IS 228(Part 2)) |
- |
|
|
|
2 (Silicon- IS 228(Part 2)) |
- |
|
|
|
2 (Copper- IS 228(P-15)) |
- |
|
|
|
|
- |
- Chem- Facility not available for Al
Mech- Excluding Critical Dimensions |
10076 |
BIS, Central Laboratory (CL)
| None
| IS 8783 : Part 4 : Sec 3 (1995) |
Winding wires for submersible motors - Specification: Part 4 specification for individual wires: Sec 3 polyester and polypropylene insulated winding wires (First Revision) |
- |
Rs.8700/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1 (The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
|
|
|
6.1 (The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
|
|
|
6.2 (BIS Certification Mark) |
- |
|
|
|
4 (i) Material) |
- |
|
|
|
5 (ii) Diameter [mm] Wire taken from cable:) |
- |
|
|
|
5 (d) Resistance test [Ohm/km corrected to 20°c) |
- |
|
|
|
5 (iii) Annealing test [Percentage] on Seperate wire:) |
- |
|
|
|
4.1, table 1 & 2 (a) Thickness of Polyster (mm)) |
- |
|
|
|
4.1, table 1 & 3 (b) Thickness of Polypropylene (mm)) |
- |
|
|
|
4.1, table 1 & 4 (c) Total thickness of Insulation(mm)) |
- |
|
|
|
4.2 (Application of insulation) |
- |
|
|
|
4.3 (Colour of Insuation) |
- |
|
|
|
4.4 (Overall diameter (mm)) |
- |
|
|
|
4 (High Voltage test [Water Immersion test] 3 KV for 1 Minute) |
- |
|
|
|
4 (Before ageing Tensile strength [N/mm²]) |
- |
|
|
|
4 (After ageing Tensile strength [N/mm²]) |
- |
|
|
|
4 (Variation on elongation at break [Percentage]) |
- |
|
|
|
4 (After Shrinkage Cracks found.) |
- |
|
|
|
4 (Before ageing Tensile strength [N/mm²]) |
- |
|
|
|
4 (Before ageing Elongation at break [Percentage]) |
- |
|
|
|
4 (After ageing Tensile strength [N/mm²]) |
- |
|
|
|
4 (Variation on tensile strangth [Percentage]) |
- |
|
|
|
4 (After ageing Elongation at break [Percentage]) |
- |
|
|
|
4 (Hot Deformation test [depth of indentation) [Percentage]) |
- |
|
|
|
4 (Heat Shock Test - No cracks found Physical) |
- |
|
|
|
Table 1, Cl. 4.1, VI (Water Absorbtion Test (Gravimetric)) |
- |
|
|
|
Cl. 4.1 of IS: 8783 (Pt-2) (Insulation Resistance Test) |
- |
|
|
|
Cl. 4.1 of IS: 8783 (Pt-2) (Insulation Resistance Test) |
- |
|
|
|
Cl.4.1 of IS: 8783 (Pt-2):1995 (Physical Test for Insulation after Ageing (on finished wire)) |
- |
|
|
|
|
- |
- - |
10077 |
BIS, Central Laboratory (CL)
| None
| IS 368 (2014) |
Electric immersion water heaters - Specification (Fifth Revision) |
- |
- View breakup
"For 1 kW & 1.5 kW: Rs.12150.00
For 2 kW and 3 kW: Rs.13050.00"
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6 of IS 302-‐2-‐201:2008 (Classification) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.8 of IS 302‐2-201: 2008 (Protection Against Access to Live Parts) |
- |
|
|
|
Cl.10 of IS 302‐2‐201:2008 (Power Input and Current ) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl. 12 of IS 368:2014 (Operation under overload conditions of appliances with heating elements) |
- |
|
|
|
Cl.13 of IS 302-2-201: 2008 (Leakage Current & Electric Strength at Operating Temperature) |
- |
|
|
|
Cl.13 of IS 302-2-201: 2009 (Leakage Current & Electric Strength at Operating Temperature) |
- |
|
|
|
Cl.15 of IS 302-2-201:2008 (Moisture Resistance ) |
- |
|
|
|
Cl.15 of IS 302-2-201:2008 (Moisture Resistance ) |
- |
|
|
|
Cl.16 of IS 302-2-201:2008 (Leakage Current & Electric Strength) |
- |
|
|
|
Cl.16 of IS 302-2-201:2008 (Leakage Current & Electric Strength) |
- |
|
|
|
Cl.17 of IS 302‐2-201: 2008 (Overload Protection of Transformers & Associated Circuits) |
- |
|
|
|
Cl.18 of IS 368:2014 (Endurance) |
- |
|
|
|
Cl.19 of IS 302‐2-201: 2008 (Abnormal Operation ) |
- |
|
|
|
Cl.19 of IS 302‐2-201: 2008 (Abnormal Operation ) |
- |
|
|
|
Cl.19 of IS 302‐2-201: 2008 (Abnormal Operation ) |
- |
|
|
|
Cl.19 of IS 302‐2-201: 2008 (Abnormal Operation ) |
- |
|
|
|
Cl.19 of IS 302‐2-201: 2008 (Abnormal Operation ) |
- |
|
|
|
Cl.20 of IS 302-2-201: 2008 (Stability & Mechanical Hazards) |
- |
|
|
|
Cl.21 of IS 302-2-201: 2008 (Mechanical Strength ) |
- |
|
|
|
Cl.21 of IS 302-2-201: 2008 (Mechanical Strength ) |
- |
|
|
|
Cl.21 of IS 302-2-201: 2008 (Mechanical Strength ) |
- |
|
|
|
Cl.22 of IS 302-2-201: 2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-201: 2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-201: 2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-201: 2008 (Construction) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.26 of IS 302-2-201: 2008 (Terminals for External Conductors) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.28 of IS 302-2-201: 2008 (Screws & Connections ) |
- |
|
|
|
Cl.29 of IS 302-2‐201:2008 (Clearances, Creepage Distances and Solid Insulation ) |
- |
|
|
|
Cl.29 of IS 302-2‐201:2008 (Clearances, Creepage Distances and Solid Insulation ) |
- |
|
|
|
Cl.30 of IS 302-2‐201:2008 (Resistance to Heat and Fire ) |
- |
|
|
|
Cl.30 of IS 302-2‐201:2008 (Resistance to Heat and Fire ) |
- |
|
|
|
Cl.31 of IS 302-2-201:2008 (Resistance of Rusting ) |
- |
|
|
|
Cl.32 of IS 302-2-201:2008 (Radiation, Toxicity and Similar Hazards) |
- |
|
|
|
|
- |
- - |
10078 |
BIS, Central Laboratory (CL)
| None
| IS 10891 : Part 1 (2001) |
Steel wire ropes for aerial ropeways - Specification: Part 1 haulage ropes (First Revision) |
- |
Rs. 1500/- + testing charges as per referred ISS. View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4. Table 1to 6 ( ROPE SIZE AND TOLERANCE) |
- |
|
|
|
4 and 5 Table 1 t0 6 (MINIMUM BREAKING FORCE OF WIRE ROPE,KN) |
- |
|
|
|
4 and 5 Table 1 t0 6 (APPROXIMATE MASS,KG/100M) |
- |
|
|
|
6 (GENERAL REQUIREMENTS IS6594) |
- |
|
|
|
6.1.1 ( i)Fibre Core IS 1804.) |
- |
|
|
|
6.1.1 ( ii)Steel Core) |
- |
|
|
|
6.2 ( Joints IS 6594.) |
- |
|
|
|
6.3 (Lay) |
- |
|
|
|
7 ( GALVANIZING) |
- |
|
|
|
|
- |
- Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
Excluding only C & S tested for dia < 3mm; Cl 5 - Minimum Breaking Force (Only for size from 18 mm to 22 mm) |
10079 |
BIS, Central Laboratory (CL)
| None
| IS 302 : Part 2 : Sec 30 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 30 room heaters (First Revision) |
- |
- View breakup
Rs.9950/- up to and including 1 Kw Rs. 10900/- up to and including 2 Kw
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6 (Classification) |
- |
|
|
|
Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 (Marking and Instructions) |
- |
|
|
|
Cl.7 (Marking and Instructions) |
- |
|
|
|
Cl.7 (Marking and Instructions) |
- |
|
|
|
Cl.7.3 (Marking and Instructions) |
- |
|
|
|
Cl.7.3 (Marking and Instructions) |
- |
|
|
|
Cl.7.3 (Marking and Instructions) |
- |
|
|
|
Cl.7.4 (Marking and Instructions) |
- |
|
|
|
Cl.7.5 (Marking and Instructions) |
- |
|
|
|
Cl.7.6 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.8 of IS :302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.9 of IS :302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.10 of IS :302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.11 of IS :302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2009 (Marking and Instructions) |
- |
|
|
|
Cl.7.13 of IS 302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.14 of IS302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.14 (Marking and Instructions) |
- |
|
|
|
Cl.7.14 (Marking and Instructions) |
- |
|
|
|
Cl.7.15 of IS 302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.15 of IS 302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.15 of IS 302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.15 of IS 302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.101 (Marking and Instructions) |
- |
|
|
|
Cl.8 & IS:302-1:2008 (Protection Against Access to Live Parts) |
- |
|
|
|
Cl.10 & IS:302-1:2008 (Power Input and Current) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11.8 (Heating) |
- |
|
|
|
Cl.11.8 (Heating) |
- |
|
|
|
Cl.11.8 (Heating) |
- |
|
|
|
Cl.13 & IS:302-1:2008 (Leakage Current & Electric Strength at operating temp. ) |
- |
|
|
|
Cl.13 & IS:302-1:2008 (Leakage Current & Electric Strength at operating temp. ) |
- |
|
|
|
Cl.15 & IS: 302-1:2008 (Moisture Resistance
) |
- |
|
|
|
Cl.15.3 of IS 302-1:200 (Moisture Resistance
) |
- |
|
|
|
Cl.16 & IS:302-1:2008 (Leakage Current & Electric Strength ) |
- |
|
|
|
Cl.16 & IS:302-1:2008 (Leakage Current & Electric Strength ) |
- |
|
|
|
Cl.18 (Endurance. ) |
- |
|
|
|
Cl.19 & IS:302-1:2008 (Abnormal Operation.) |
- |
|
|
|
Cl.19 & IS:302-1:2008 (Abnormal Operation.) |
- |
|
|
|
Cl.19 & IS:302-1:2008 (Abnormal Operation.) |
- |
|
|
|
Cl.19.101 (Abnormal Operation.) |
- |
|
|
|
Cl.19.102 (Abnormal Operation.) |
- |
|
|
|
Cl.19.103 (Abnormal Operation.) |
- |
|
|
|
Cl.19.104 (Abnormal Operation.) |
- |
|
|
|
Cl.19.105 (Abnormal Operation.) |
- |
|
|
|
Cl.19.106 (Abnormal Operation.) |
- |
|
|
|
Table 8 of IS 302-1:2008 (Abnormal Operation.) |
- |
|
|
|
Cl.19.107 (Abnormal Operation.) |
- |
|
|
|
Cl.19.108 (Abnormal Operation.) |
- |
|
|
|
Cl.19.109 (Abnormal Operation.) |
- |
|
|
|
Cl.19.110 (Abnormal Operation.) |
- |
|
|
|
Cl.19.111 (Abnormal Operation.) |
- |
|
|
|
Cl.19.114 (Abnormal Operation.) |
- |
|
|
|
Cl.20 & IS:302-1:2008 (Stability & Mechanical Hazards) |
- |
|
|
|
Cl.21 & IS:302-1:2008) (Mechanical Strength.) |
- |
|
|
|
Cl.21.2 of IS 302-1:2008 (Mechanical Strength.) |
- |
|
|
|
Cl.21.101 (Mechanical Strength.) |
- |
|
|
|
Cl.21.102 (Mechanical Strength.) |
- |
|
|
|
Cl.21.103 (Mechanical Strength.) |
- |
|
|
|
Cl.22.1 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.5 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.6 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.7 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.8 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.9 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.11 (Construction) |
- |
|
|
|
Cl.22.12 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.13 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.14 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.15 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.18 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.20 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.21 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.23 & IS:302-1:2008 (Internal Wiring
) |
- |
|
|
|
Cl.23.4 & Cl.29 of 302-1:2008 (Internal Wiring
) |
- |
|
|
|
Cl.23.5 of 302-1:2008 (Internal Wiring
) |
- |
|
|
|
Cl.23.7 of 302-1:2008 (Internal Wiring
) |
- |
|
|
|
C.23.7 of 302-1:2008 (Internal Wiring
) |
- |
|
|
|
Cl.24.1 of 302-1:2008 (Component) |
- |
|
|
|
Cl.24.1 of 302-1:2008 (Component) |
- |
|
|
|
Cl.24.1.3 (Component) |
- |
|
|
|
Cl.24.1.3 (Component) |
- |
|
|
|
Cl.24.1.3 (Component) |
- |
|
|
|
C.24.1.4 (Component) |
- |
|
|
|
C.24.2 of 302-1:2008 (Component) |
- |
|
|
|
Cl.24.10 (Component) |
- |
|
|
|
Cl.25.1 of 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl. 25.2 of IS 3021:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl. 25.3 of IS 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl. 25.4 of IS 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25.5 of 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25.6 of 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25.7. (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25.8 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl. 25.9 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25.10 of 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl. 25.11 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl. 25.12 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl. 25.13 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25.14 of IS 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25.15 of IS 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25.17 of IS 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25.18 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25.20 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.26.1 of IS 302-1:2008 (Terminal for External Conductors
) |
- |
|
|
|
Cl.26.10 of IS 302-1:2008 (Terminal for External Conductors
) |
- |
|
|
|
Cl.26.11 of IS 302-1:2008 (Terminal for External Conductors
) |
- |
|
|
|
Cl.27.1 of 302-1:2008 (Provision for Earthing.) |
- |
|
|
|
Cl.27.5 of 302-1:2008 (Provision for Earthing.) |
- |
|
|
|
Cl.28 of 302-1:2008 (Screws and Connections.) |
- |
|
|
|
Cl.29 & IS:302-1:2008 (Clearances, Creepage Distances and Solid Insulation) |
- |
|
|
|
Cl.29 & IS:302-1:2008 (Clearances, Creepage Distances and Solid Insulation) |
- |
|
|
|
Cl.30 & IS:302-1:2008 (Resistance to Heat and Fire) |
- |
|
|
|
Cl.30.2.2 of 302-1:2008 (Resistance to Heat and Fire) |
- |
|
|
|
Cl.31 & IS:302-1:2008 (Resistance to Rusting.) |
- |
|
|
|
Cl.32 & IS:302-1:2008 (Radition,Toxicity and similar Hazards.) |
- |
|
|
|
|
- |
- Excluding electronic circuit type appliances(Cl.19.11 of IS 302 part 1) |
10080 |
BIS, Central Laboratory (CL)
| None
| IS 8783 : Part 4 : Sec 1 (1995) |
Winding wires for submersible motors - Specification: Part 4 specification for indmdual wires: Sec 1 HR PVC insulated wires (First Revision) |
- |
9300/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.3.1 (Conductor) |
- |
|
|
|
Cl.4 (Material) |
- |
|
|
|
Cl.5.1.1 (Dimensions) |
- |
|
|
|
Cl. 6 (Annealing Test) |
- |
|
|
|
Cl 6 (Resistance Test) |
- |
|
|
|
Cl.4.1 (Insulation ) |
- |
|
|
|
Cl.4.2 (Application) |
- |
|
|
|
Cl.4.3 (Colour) |
- |
|
|
|
Cl.4.4 (Overall Diameter) |
- |
|
|
|
Cl.4.5 (Finish) |
- |
|
|
|
Cl.4.6 (High Voltage Test Water Immersion ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Volume resistivity) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Volume resistivity) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Tensile strength ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Elongation) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Tensile Strength) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Variation) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Elongation at Break ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Variation) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Shrinkage test ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Shrinkage test ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Water absorption (Gravimetric) ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Hot deformation Test ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Heat shock Test ) |
- |
|
|
|
Cl.3.2 (Dielectric Material ) |
- |
|
|
|
|
- |
- - |