| 10441 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 14885 (2022) |
Polyethylene Pipes for the Supply of Gaseous Fuels � Specification (First Revision) |
For all sizes except test mentioned in remarks |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.3 (Nominal Diameter) |
- |
|
|
|
| 4.4 (Colour) |
- |
|
|
|
| 6.1 (Mean out side Diameter (For less than or equal to 25 mm- Average of 8 , For higher diameters average of 6)) |
- |
|
|
|
| 6.1 (Out of Roundness (Ovality)) |
- |
|
|
|
| 6.2 (Wall thickness (Take 8 reading and Average will be repoted)) |
- |
|
|
|
| 7 (Finish) |
- |
|
|
|
| 8.2 (Reversion Test) |
- |
|
|
|
| 8.8 (Tensile Properties (Tensile Yield Strength and
Elongation at Break)) |
- |
|
|
|
| 8.4 (Melt Flow Rate (MFR)) |
- |
|
|
|
| 8.8 (Tensile Properties (Tensile Yield Strength and Elongation at Break)) |
- |
|
|
|
| 8.7 (Volatile Matter Content) |
- |
|
|
|
| 6.1 (Mean out side Diameter (For less than or equal to 25 mm- Average of 8 , For higher diameters average of 6)) |
- |
|
|
|
| 6.2 (Wall thickness (Take 8 reading and Average will be repoted)) |
- |
|
|
|
|
- |
- Facility not available for thermal stability, Hydraulic characteristics, water content and thermal stability |
| 10442 |
ABSOLUTE TESTING SERVICES, FARIDABAD
| 8174526
| IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
- |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking and instructions) |
- |
4500 |
|
- |
| 6(Hazardous radiations) |
- |
4500 |
|
- |
| 7(Heating under normal operating conditions) |
- |
4500 |
|
- |
| 8(Constructional requirements with regard to the protection against electric shock) |
- |
4500 |
|
- |
| 9(Electric shock hazard under normal operating conditions) |
- |
4500 |
|
- |
| 10(Insulation requirements) |
- |
4500 |
|
- |
| 11(Fault conditions) |
- |
4500 |
|
- |
| 12(Mechanical strength) |
- |
4500 |
|
- |
| 13(CLEARANCES and CREEPAGE DISTANCES) |
- |
4500 |
|
- |
| 14(Components) |
- |
4500 |
|
- |
| 15(TERMINALS) |
- |
4500 |
|
- |
| 16(External flexible cords) |
- |
4500 |
|
- |
| 17(Electrical connections and mechanical fixings) |
- |
4500 |
|
- |
| 19(Stability and mechanical hazards) |
- |
4500 |
|
- |
| 20(Resistance to fire) |
- |
4500 |
|
- |
| 6.1(Ionizing radiation) |
- |
4500 |
|
- |
| 6.2(Laser Radiation) |
- |
4500 |
|
- |
| 8.16/ H 2.2/ H 2.3(Requirements for insulated winding wires for use without additional interleaved insulation) |
- |
4500 |
|
- |
| 16.3b(Cord Bending Test) |
- |
4500 |
|
- |
| Annex-A(Additional requirements for apparatus with protection against splashing water) |
- |
4500 |
|
- |
| 6.3() |
- |
4500 |
|
- |
| Annex-B(Apparatus to be connected to the TELECOMMUNICATION NETWORKS) |
- |
4500 |
|
- |
|
13 Nov, 2026 |
- Exclusion: Cl. 18 (Mechanical strength of picture tubes and protection against the effects of implosion), Cl. 14 (Components) |
| 10443 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
65000 View breakup
Class I & II Product : (AUTOMATIC DATA PROCESSING MACHINE, VISUAL DISPLAY UNITS, VIDEOS MONITORS OF SCREEN SIZE 32" AND ABOVE, COPYING MACHINES/DUPLICATORS, AUTOMATIC TELLER CASH DISPENSING MACHINES, PRINTERS, PLOTTERS, SCANNERS, SET TOP BOX, POWER ADAPTORS FOR IT EQUIPMENTS, VIS JAL DISPLAY UNITS, VIDEO MONITORS OF SCREEN SIZE UPTO 32, STANDALONE SWITCH MODE POWER SUPPLIES (SMPS) WITH OUTPUT VOLTAGE 48V (MAX), DIGITAL CAMERA, TELEPHONE ANSWERING MACHINES, CASH REGISTERS).- Rs. 65000/-
Class III Product : (LAPTOP/NOTEBOOK/TABLET, PASSPORT READER, POINT OF SALE TERMINALS, MAIL PROCESSING MACHINES/POSTAGE MACHINES/FRANKING MACHINES, POWER BANKS FOR USE IN PORTABLE APPLICATIONS, SMART CARD READER, MOBILE PHONES, CCTV CAMERAS/CCTV RECORDERS, USB DRIVEN BARCODE READERS, BARCODE SCANNERS, IRIS SCANNERS, OPTICAL FINGERPRINT SCANNERS, SMART WATCHES, KEYBOARD, USB TYPE EXTERNAL HARD DISK DRIVE, USB TYPE EXTERNAL SOLID-STATE STORAGE DEVICES (ABOVE 256 GB CAPACITY), WIRELESS KEYBOARDS).- Rs. 40000/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.6(Power interface .) |
- |
3000 |
|
- |
| 1.7(Markings and instructions) |
- |
1000 |
|
- |
| 2.1(Protection from electric shock and energy hazards) |
- |
2000 |
|
- |
| 2.2(SELV circuits) |
- |
1000 |
|
- |
| 2.3(TNV circuits) |
- |
1000 |
|
- |
| 2.4(Limited current circuits) |
- |
1000 |
|
- |
| 2.5(Limited power sources .) |
- |
1000 |
|
- |
| 2.6(Provisions for earthing and bonding) |
- |
1000 |
|
- |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
1000 |
|
- |
| 2.8(Safety interlocks) |
- |
3000 |
|
- |
| 2.9(Electrical insulation) |
- |
1000 |
|
- |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
2000 |
|
- |
| 3.1(General) |
- |
500 |
|
- |
| 3.2(Connection to a mains supply) |
- |
2000 |
|
- |
| 3.3(Wiring terminals for connection of external conductors) |
- |
1000 |
|
- |
| 3.5(Interconnection of equipment) |
- |
1000 |
|
- |
| 4.1(Stability) |
- |
1000 |
|
- |
| 4.2(Mechanical strength) |
- |
1000 |
|
- |
| 4.4(Protection against hazardous moving parts) |
- |
2000 |
|
- |
| 4.5(Thermal requirements) |
- |
5000 |
|
- |
| 4.7(Resistance to fire) |
- |
4000 |
|
- |
| 5.1(Touch current and protective conductor curren) |
- |
1000 |
|
- |
| 5.2(Electric strength) |
- |
1000 |
|
- |
| 5.3(Abnormal operating and fault conditions) |
- |
1000 |
|
- |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
3000 |
|
- |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
3000 |
|
- |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
1000 |
|
- |
| Annex B(Motor tests under abnormal conditions) |
- |
1000 |
|
- |
| Annex C(Transformers) |
- |
1000 |
|
- |
| Annex DD(Requirements for the mounting means of a rack mounted equipment) |
- |
1000 |
|
- |
| Annex EE(Household and home/ office document/ media shredders) |
- |
1000 |
|
- |
| 3.4(Disconnection from the mains supply) |
- |
2000 |
|
- |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
1000 |
|
- |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
1000 |
|
- |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
1000 |
|
- |
| 1.5(Components) |
- |
500 |
|
- |
| 4.6(Openings in enclosures) |
- |
500 |
|
- |
| 7.1(General) |
- |
500 |
|
- |
| 2.8.2/2.8.5(Interlock switches) |
- |
2000 |
|
- |
| 2.10.4.2(Material Group and Comparative Tracking Index) |
- |
1000 |
|
- |
| 2.10.6(PCB material) |
- |
1000 |
|
- |
| 4.6.2(Bottoms of fire enclosures) |
- |
500 |
|
- |
| 2.10.8.4(Abrasion resistance test) |
- |
1000 |
|
- |
| Annex A3(Hot flaming oil test) |
- |
1000 |
|
- |
| 4.3(Design and construction) |
- |
500 |
|
- |
| 2.10.8.2(Thermal conditioning (thermal ageing)) |
- |
1000 |
|
- |
| 2.10.9(Thermal Cycling) |
- |
1000 |
|
- |
|
29 Apr, 2027 |
- Exclusion: Cl. 4.3.13.2 (Ionizing radiation), Cl. 4.3.13.5 (LED, laser class), Cl. 2.10.5.3 (Insulating Compound as Solid Insulation), Cl. 2.10.5.4 (Opto-coupler), Cl. 2.10.5.6 (Thin sheet materials), Cl. 2.10.5.11 (SMPS Transformer and Inductor), Cl. 2.10.5.12 (Wires in wound components), Cl. 2.10.5.13 (Winding wire), Cl. 2.10.5.14 (Additional insulation in wound components), Cl. 2.10.12 (Enclosed and sealed parts), Cl. 3.2.4 (Appliance inlet /connector), Cl. 3.2.5 (Non re-wirable plug with PVC sheathed cable), Cl. 4.2.8 (Cathode Ray Tubes), Cl. 4.3.8 (Batteries), Cl. 4.3.12 (Flammable liquids), Cl. 4.3.13.3/ Annex Y (Effect of UV radiation on material/Ultraviolet conditioning test), Cl. 4.3.13.4 (Human exposure to ultraviolet (UV) radiation), Annex U (Insulating winding wires for use without interleaved insulation), Annex CC (Evaluation of integrated circuit (IC) current limiters), Cl. 4.3.10 (Dust, powders, liquids and gases), Cl. 4.3.11 (Containers for liquids or gases), Cl. 2.8.7 (Switches and Relay), Annex Q (Voltage Dependent Resistors), Annex K (Thermal Control), Cl. 2.10.10 (Test for Pollution Degree 1 environment and for insulating compound), Cl. 2.10.11 (Tests for semiconductor devices and for cemented joints), Cl. 3.2.4 (Appliance inlet /connector), Cl. 3.1.4 (Internal wire), Cl. 1.5 (Components) |
| 10444 |
THE SOUTH INDIA TEXTILE RESEARCH ASSOCIATION (SITRA), COIMBATORE
| 6165234
| IS 863 (1988) |
Specification for cotton bandage cloth, non-sterilized (second revision) |
- |
4000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table 1(Warp, 20 to 25 tex ( 24s to 30s )) |
- |
300 |
|
- |
| Table 1(Weft, 25 to 30 tex ( 20s to 24s )) |
- |
0 |
|
- |
| Table 1(Threads, dm, Min) |
- |
300 |
|
- |
| Table 1(Ends, ) |
- |
0 |
|
- |
| Table 1(Picks,) |
- |
0 |
|
- |
| Table 1(Mass, g/m²,) |
- |
300 |
|
- |
| Table 1(Length, m) |
- |
300 |
|
- |
| Table 1(Width, cm,) |
- |
300 |
|
- |
| Table 1(pH value of aqueous extract,) |
- |
250 |
|
- |
| Table 1(Scouring loss, Max) |
- |
500 |
|
- |
| Table 1(Freedom from optical ) |
- |
250 |
|
- |
| Table 1(Light, ) |
- |
1200 |
|
Upto BWS 3 scale |
| Table 1(Washing: Test 3) |
- |
300 |
|
- |
| Table 1(ii) Staining on adjacent fabric,) |
- |
0 |
|
- |
| Table 1(Warp, 20 to 25 tex ( 24s to 30s )) |
- |
0 |
|
Parameter repeated |
| Table 1(Weft, 25 to 30 tex ( 20s to 24s )) |
- |
0 |
|
Parameter repeated |
| Table 1(Threads, dm, Min) |
- |
0 |
|
Parameter repeated |
| Table 1(Ends, ) |
- |
0 |
|
Parameter repeated |
| Table 1(Picks,) |
- |
0 |
|
Parameter repeated |
| Table 1(Mass, g/m²,) |
- |
0 |
|
Parameter repeated |
| Table 1(Length, m) |
- |
0 |
|
Parameter repeated |
| Table 1(Width, cm,) |
- |
0 |
|
Parameter repeated |
| Table 1(pH value of aqueous extract,) |
- |
0 |
|
Parameter repeated |
| Table 1(Scouring loss, Max) |
- |
0 |
|
Parameter repeated |
| Table 1(Freedom from optical ) |
- |
0 |
|
Parameter repeated |
| Table 1(Light, ) |
- |
0 |
|
Parameter repeated |
| Table 1(i) Change in colour,) |
- |
0 |
|
Parameter repeated |
| Table 1(ii) Staining on adjacent fabric,) |
- |
0 |
|
Parameter repeated |
| Clause 3.1 & Table 1(vi)(pH value of acqueous extract) |
- |
0 |
|
Parameter repeated |
| Clause 3.1 & Table 1(vii)(Scouring loss) |
- |
0 |
|
Parameter repeated |
| Clause 3.1 & Table 1(viii)("Freedom from optical
whiteners ") |
- |
0 |
|
Parameter repeated |
| Table 1(Warp, 20 to 25 tex ( 24s to 30s )) |
- |
- |
|
- |
| Table 1(Weft, 25 to 30 tex ( 20s to 24s )) |
- |
- |
|
- |
| Table 1(Threads, dm, Min) |
- |
- |
|
- |
| Table 1(Ends, ) |
- |
- |
|
- |
| Table 1(Picks,) |
- |
- |
|
- |
| Table 1(Mass, g/m²,) |
- |
- |
|
- |
| Table 1(Length, m) |
- |
- |
|
- |
| Table 1(Width, cm,) |
- |
- |
|
- |
| Table 1(pH value of aqueous extract,) |
- |
- |
|
- |
| Table 1(Scouring loss, Max) |
- |
- |
|
- |
| Table 1(Freedom from optical ) |
- |
- |
|
- |
| Table 1(Light, ) |
- |
- |
|
- |
| Table 1(i) Change in colour,) |
- |
- |
|
- |
| Table 1(ii) Staining on adjacent fabric,) |
- |
- |
|
- |
| Clause 3.1 & Table 1(vi)(pH value of acqueous extract) |
- |
- |
|
- |
| Clause 3.1 & Table 1(vii)(Scouring loss) |
- |
- |
|
- |
| Clause 3.1 & Table 1(viii)("Freedom from optical
whiteners ") |
- |
- |
|
- |
|
- |
- - |
| 10445 |
THE SOUTH INDIA TEXTILE RESEARCH ASSOCIATION (SITRA), COIMBATORE
| 6165234
| IS 758 (1988) |
Specification for cotton gauze, absorbent, non-sterilized (fourth revision) |
- |
4025 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1,Table 1,Sr.No.i(Count of yarn
a) Warp
) |
- |
375 |
|
- |
| 3.1,Table 1,Sr.No.i(Count of yarn
b) Weft) |
- |
0 |
|
- |
| 3.1,Table 1,Sr.No.ii
Appendix A(Threads/dm
a) Ends) |
- |
250 |
|
- |
| 3.1,Table 1,Sr.No.ii
Appendix A(Threads/dm
b) Picks) |
- |
0 |
|
- |
| 3.1,Table 1,Sr.No.iii
IS 1964(Mass ) |
- |
250 |
|
- |
| 3.1,Table 1,Sr.No.iv
IS 1954(Length) |
- |
250 |
|
- |
| 3.1,Table 1,Sr.No.v
Appendix A(Width,) |
- |
0 |
|
- |
| 3.1,Table 1,Sr.No.vi
IS : 2369(Absorbency) |
- |
1550 |
|
- |
| 3.1,Table 1,Sr.No.vii
IS : 1390(pH value) |
- |
250 |
|
- |
| 3.1,Table 1,Sr.No.viii
IS : 1383(Scouring Loss) |
- |
600 |
|
- |
| 3.1,Table 1,Sr.No.ix
(Freedom from optical whitener) |
- |
250 |
|
- |
| 5
Appendix B(PACKING) |
- |
250 |
|
- |
|
- |
- - |
| 10446 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 8887 (2018) |
Bitumen emulsion for roads (Cationic Type) - Specification (Third Revision) |
- |
18800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl: 3.1(Cationic Emulsion for all grade) |
- |
2800 |
|
For Cationic Emulsion |
| CL: 4.4.1(Material For all grades) |
- |
2800 |
|
For material for all grades |
| CL: 4.4.2(Material For all grades) |
- |
2800 |
|
For material for all grades |
| 6.6.1(Requirement for all grades) |
- |
2800 |
|
For Residue on 600 micron |
| 6.6.2 Table-1; 1(i)(Residue on 600 micron IS Sieve, (Grad RS-1) IS 8, Annex 9) |
- |
2800 |
|
For Residue on 600 micron |
| 6.6.2 Table-1; 1(i)(Residue on 600 micron IS Sieve, (Grad RS-2) Annex 9) |
- |
2800 |
|
For Residue on 600 micron |
| 6.6.2 Table-1; 1(i)(Residue on 600 micron IS Sieve, (Grad MS) Annex 9) |
- |
2800 |
|
For Residue on 600 micron |
| 6.6.2 Table-1; 1(i)(Residue on 600 micron IS Sieve, (Grad SS-1) Annex 9) |
- |
2800 |
|
For Residue on 600 micron |
| 6.6.2 Table-1; 1(i)(Residue on 600 micron IS Sieve, (Grad SS-2) Annex 9) |
- |
2800 |
|
For Residue on 600 micron |
| 6.6.2 Table-1; 1(ii) (1)(Viscosity by saybolt furol viscometer, seconds (Grad RS-1), IS 3117) |
- |
2000 |
|
For viscosity by saybolut furol viscometer |
| 6.6.2 Table-1; 1(ii) (1)(Viscosity by saybolt furol viscometer, seconds (Grad RS-2) |
- |
2000 |
|
For viscosity by saybolut furol viscometer |
| 6.6.2 Table-1; 1(ii) (1)(Viscosity by saybolt furol viscometer, seconds (Grad MS), IS 3117) |
- |
2000 |
|
For viscosity by saybolut furol viscometer |
| 6.6.2 Table-1; 1(ii) (1)(Viscosity by saybolt furol viscometer, seconds (Grad SS-1), IS 3117) |
- |
2000 |
|
For viscosity by saybolut furol viscometer |
| 6.6.2 Table-1; 1(ii) (1)(Viscosity by saybolt furol viscometer, seconds (Grad SS-2), IS 3117) |
- |
2000 |
|
For viscosity by saybolut furol viscometer |
| 6.6.2 Table-1; 1(ii) (2)(Viscosity by saybolt furol viscometer, seconds (Grad RS-1), IS 3117) |
- |
2000 |
|
For viscosity by saybolut furol viscometer |
| 6.6.2 Table-1; 1(ii) (2)(Viscosity by saybolt furol viscometer, seconds (Grad RS-2, IS 3117) |
- |
2000 |
|
For viscosity by saybolut furol viscometer |
| 6.6.2 Table-1; 1(ii) (2)(Viscosity by saybolt furol viscometer, seconds (Grad MS), IS 3117) |
- |
2000 |
|
For viscosity by saybolut furol viscometer |
| 6.6.2 Table-1; 1(ii) (2)(Viscosity by saybolt furol viscometer, seconds (Grad SS-1), IS 3117) |
- |
2000 |
|
For viscosity by saybolut furol viscometer |
| 6.6.2 Table-1; 1(ii) (2)(Viscosity by saybolt furol viscometer, seconds (Grad SS-2), IS 3117) |
- |
2000 |
|
For viscosity by saybolut furol viscometer |
| 6.6.2 Table-1; 1(iii)(Coagulation of emulsion at low temperature (Grad RS-1), Annex C) |
- |
1500 |
|
For Coagulation of emulsion |
| 6.6.2 Table-1; 1(iii)(Coagulation of emulsion at low temperature (Grad RS-2), Annex C) |
- |
1500 |
|
For Coagulation of emulsion |
| 6.6.2 Table-1; 1(iii)(Coagulation of emulsion at low temperature (Grad MS), Annex C) |
- |
1500 |
|
For Coagulation of emulsion |
| 6.6.2 Table-1; 1(iii)(Coagulation of emulsion at low temperature (Grad SS-1), Annex C) |
- |
1500 |
|
For Coagulation of emulsion |
| 6.6.2 Table-1; 1(iii)(Coagulation of emulsion at low temperature (Grad SS-2), Annex C) |
- |
1500 |
|
For Coagulation of emulsion |
| 6.6.2 Table-1; 1(iv)(Storage stability after 24 h (Grad RS-1), Annex D) |
- |
1500 |
|
For Storage stability |
| 6.6.2 Table-1; 1(iv)(Storage stability after 24 h (Grad RS-2), Annex D) |
- |
1500 |
|
For Storage stability |
| 6.6.2 Table-1; 1(iv)(Storage stability after 24 h (Grade MS), Annex D) |
- |
1500 |
|
For Storage stability |
| 6.6.2 Table-1; 1(iv)(Storage stability after 24 h (Grade SS-1), Annex D) |
- |
1500 |
|
For Storage stability |
| 6.6.2 Table-1; 1(iv)(Storage stability after 24 h (Grade SS-2), Annex D) |
- |
1500 |
|
For Storage stability |
| 6.6.2 Table-1; 1(v)(Particle charge (Grad RS-1), Annex E) |
- |
1000 |
|
For Particle charge |
| 6.6.2 Table-1; 1(v)(Particle charge (Grad RS-2), Annex E) |
- |
1000 |
|
For Particle charge |
| 6.6.2 Table-1; 1(v)(Particle charge (Grad MS), Annex E) |
- |
1000 |
|
For Particle charge |
| 6.6.2 Table-1; 1(v)(Particle charge (Grad SS-1), Annex E) |
- |
1000 |
|
For Particle charge |
| 6.6.2 Table-1; 1(v)(Particle charge (Grad SS-2), Annex E) |
- |
1000 |
|
For Particle charge |
| 6.6.2 Table-1; 1(vi) 1(Coating ability and water resistance:
Coating, dry aggregate (Grade RS-1) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vi) 1(Coating ability and water resistance:
Coating, dry aggregate (Grade RS-2) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vi) 1(Coating ability and water resistance:
Coating, dry aggregate (Grade MS) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vi) 1(Coating ability and water resistance:
Coating, dry aggregate (Grade SS-1) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vi) 1(Coating ability and water resistance:
Coating, dry aggregate (Grade SS-2) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vi) 2(Coating ability and water resistance:
Coating, after spraying (Grade RS-1) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vi) 2(Coating ability and water resistance:
Coating, after spraying (Grade RS-2) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vi) 2(Coating ability and water resistance:
Coating, after spraying (Grade MS) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vi) 2(Coating ability and water resistance:
Coating, after spraying (Grade SS-1) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vi) 2(Coating ability and water resistance:
Coating, after spraying (Grade SS-2) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vi) 3(Coating ability and water resistance:
Coating, wet aggregate (Grade RS-1) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vi) 3(Coating ability and water resistance:
Coating, wet aggregate (Grade RS-2) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vi) 3(Coating ability and water resistance:
Coating, wet aggregate (Grade MS) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vi) 3(Coating ability and water resistance:
Coating, wet aggregate (Grade SS-1) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vi) 3(Coating ability and water resistance:
Coating, wet aggregate (Grade SS-2) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vi) 4(Coating ability and water resistance:
Coating, After Spraying (Grade RS-1) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vi) 4(Coating ability and water resistance:
Coating, After Spraying (Grade RS-2) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vi) 4(Coating ability and water resistance:
Coating, After Spraying (Grade MS) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vi) 4(Coating ability and water resistance:
Coating, After Spraying (Grade SS-1) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vi) 4(Coating ability and water resistance:
Coating, After Spraying (Grade SS-2) Annex F) |
- |
2000 |
|
For coating ability and water resistance |
| 6.6.2 Table-1; 1(vii)(Stability to mixing with cement (Grade RS-1) Annex G) |
- |
2000 |
|
For stability to mixing with cement |
| 6.6.2 Table-1; 1(vii)(Stability to mixing with cement (Grade RS-2) Annex G) |
- |
2000 |
|
For stability to mixing with cement |
| 6.6.2 Table-1; 1(vii)(Stability to mixing with cement (Grade MS) Annex G) |
- |
2000 |
|
For stability to mixing with cement |
| 6.6.2 Table-1; 1(vii)(Stability to mixing with cement (Grade SS-1) Annex G) |
- |
2000 |
|
For stability to mixing with cement |
| 6.6.2 Table-1; 1(vii)(Stability to mixing with cement (Grade SS-2) Annex G) |
- |
2000 |
|
For stability to mixing with cement |
| 6.6.2 Table-1; 1(viii)(Miscibility with water (Grade RS-1) Annex H) |
- |
2000 |
|
For Miscibillity with water |
| 6.6.2 Table-1; 1(viii)(Miscibility with water (Grade RS-2) Annex H) |
- |
2000 |
|
For Miscibillity with water |
| 6.6.2 Table-1; 1(viii)(Miscibility with water (Grade MS) Annex H) |
- |
2000 |
|
For Miscibillity with water |
| 6.6.2 Table-1; 1(viii)(Miscibility with water (Grade SS-1) Annex H) |
- |
2000 |
|
For Miscibillity with water |
| 6.6.2 Table-1; 1(viii)(Miscibility with water (Grade SS-2) Annex H) |
- |
2000 |
|
For Miscibillity with water |
| 6.6.2 Table-1; 1(ix) 1(Tests on residue: Residue by evaporation (Grade RS-1) Annex J) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(ix) 1(Tests on residue: Residue by evaporation (Grade RS-2) Annex J) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(ix) 1(Tests on residue: Residue by evaporation (Grade MS) Annex J) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(ix) 1(Tests on residue: Residue by evaporation (Grade SS-1) Annex J) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(ix) 1(Tests on residue: Residue by evaporation (Grade SS-2) Annex J) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(ix) 2(Tests on residue: Penetration (Grade RS-1) IS 1203) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(ix) 2(Tests on residue: Penetration (Grade RS-2) IS 1203) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(ix) 2(Tests on residue: Penetration (Grade MS) IS 1203) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(ix) 2(Tests on residue: Penetration (Grade SS-1) IS 1203) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(ix) 2(Tests on residue: Penetration (Grade SS-2) IS 1203) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(ix) 3(Tests on residue: Ductility (Grade RS-1) IS 1208) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(ix) 3(Tests on residue: Ductility (Grade RS-2) IS 1208) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(ix) 3(Tests on residue: Ductility (Grade MS) IS 1208) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(ix) 3(Tests on residue: Ductility (Grade SS-1) IS 1208) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(ix) 3(Tests on residue: Ductility (Grade SS-2) IS 1208) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(ix) 4(Tests on residue: Solubility I tricholoethylne,
(Grade RS-1) IS 1216) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(ix) 4(Tests on residue: Solubility I tricholoethylne,
(Grade RS-2) IS 1216) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(ix) 4(Tests on residue: Solubility I tricholoethylne,
(Grade MS) IS 1216) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(ix) 4(Tests on residue: Solubility I tricholoethylne,
(Grade SS-1) IS 1216) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(ix) 4(Tests on residue: Solubility I tricholoethylne,
(Grade SS-2) IS 1216) |
- |
1000 |
|
For Tests on Residue |
| 6.6.2 Table-1; 1(x) 1(Distillation in percent volume of distillate recovered at 360°C (Grade RS-1)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 1(Distillation in percent volume of distillate recovered at 360°C (Grade RS-2)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 1(Distillation in percent volume of distillate recovered at 360°C (Grade MS)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 1(Distillation in percent volume of distillate recovered at 360°C (SS-1)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 1(Distillation in percent volume of distillate recovered at 360°C (Grade SS-2)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 2(Distillation in percent volume of distillate recovered at 360°C (Grade RS-1)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 2(Distillation in percent volume of distillate recovered at 360°C (Grade RS-2)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 2(Distillation in percent volume of distillate recovered at 360°C (Grade MS)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 2(Distillation in percent volume of distillate recovered at 360°C (SS-1)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 2(Distillation in percent volume of distillate recovered at 360°C (Grade SS-2)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 3(Distillation in percent volume of distillate recovered at 360°C (Grade RS-1)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 3(Distillation in percent volume of distillate recovered at 360°C (Grade RS-2)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 3(Distillation in percent volume of distillate recovered at 360°C (Grade MS)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 3(Distillation in percent volume of distillate recovered at 360°C (SS-1)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 3(Distillation in percent volume of distillate recovered at 360°C (Grade SS-2)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 4(Distillation in percent volume of distillate recovered at 360°C (Grade RS-1)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 4(Distillation in percent volume of distillate recovered at 360°C (Grade RS-2)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 4(Distillation in percent volume of distillate recovered at 360°C (Grade MS)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 4(Distillation in percent volume of distillate recovered at 360°C (SS-1)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 4(Distillation in percent volume of distillate recovered at 360°C (Grade SS-2)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 5(Distillation in percent volume of distillate recovered at 360°C (Grade RS-1)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 5(Distillation in percent volume of distillate recovered at 360°C (Grade RS-2)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 5(Distillation in percent volume of distillate recovered at 360°C (Grade MS)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 5(Distillation in percent volume of distillate recovered at 360°C (SS-1)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(x) 5(Distillation in percent volume of distillate recovered at 360°C (Grade SS-2)) |
- |
2000 |
|
For Distillation in percent volume of distillate recovered at 360 degree |
| 6.6.2 Table-1; 1(xi)(Water content (Grade RS-1)) |
- |
1000 |
|
For Water Content |
| 6.6.2 Table-1; 1(xi)(Water content (Grade RS-2)) |
- |
1000 |
|
For Water Content |
| 6.6.2 Table-1; 1(xi)(Water content (Grade MS)) |
- |
1000 |
|
For Water Content |
| 6.6.2 Table-1; 1(xi)(Water content (Grade SS-1)) |
- |
1000 |
|
For Water Content |
| 6.6.2 Table-1; 1(xi)(Water content (Grade SS-2)) |
- |
1000 |
|
For Water Content |
| Cl: 3.1(Cationic Emulsion for all grade) |
- |
- |
|
- |
| CL: 4.4.1(Material For all grades) |
- |
- |
|
- |
| CL: 4.4.2(Material For all grades) |
- |
- |
|
- |
| 6.6.1(Requirement for all grades) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(i)(Residue on 600 micron IS Sieve, (Grad RS-1) IS 8, Annex 9) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(i)(Residue on 600 micron IS Sieve, (Grad RS-2) Annex 9) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(i)(Residue on 600 micron IS Sieve, (Grad MS) Annex 9) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(i)(Residue on 600 micron IS Sieve, (Grad SS-1) Annex 9) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(i)(Residue on 600 micron IS Sieve, (Grad SS-2) Annex 9) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ii) (1)(Viscosity by saybolt furol viscometer, seconds (Grad RS-1), IS 3117) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ii) (1)(Viscosity by saybolt furol viscometer, seconds (Grad RS-2) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ii) (1)(Viscosity by saybolt furol viscometer, seconds (Grad MS), IS 3117) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ii) (1)(Viscosity by saybolt furol viscometer, seconds (Grad SS-1), IS 3117) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ii) (1)(Viscosity by saybolt furol viscometer, seconds (Grad SS-2), IS 3117) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ii) (2)(Viscosity by saybolt furol viscometer, seconds (Grad RS-1), IS 3117) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ii) (2)(Viscosity by saybolt furol viscometer, seconds (Grad RS-2, IS 3117) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ii) (2)(Viscosity by saybolt furol viscometer, seconds (Grad MS), IS 3117) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ii) (2)(Viscosity by saybolt furol viscometer, seconds (Grad SS-1), IS 3117) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ii) (2)(Viscosity by saybolt furol viscometer, seconds (Grad SS-2), IS 3117) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(iii)(Coagulation of emulsion at low temperature (Grad RS-1), Annex C) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(iii)(Coagulation of emulsion at low temperature (Grad RS-2), Annex C) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(iii)(Coagulation of emulsion at low temperature (Grad MS), Annex C) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(iii)(Coagulation of emulsion at low temperature (Grad SS-1), Annex C) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(iii)(Coagulation of emulsion at low temperature (Grad SS-2), Annex C) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(iv)(Storage stability after 24 h (Grad RS-1), Annex D) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(iv)(Storage stability after 24 h (Grad RS-2), Annex D) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(iv)(Storage stability after 24 h (Grade MS), Annex D) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(iv)(Storage stability after 24 h (Grade SS-1), Annex D) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(iv)(Storage stability after 24 h (Grade SS-2), Annex D) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(v)(Particle charge (Grad RS-1), Annex E) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(v)(Particle charge (Grad RS-2), Annex E) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(v)(Particle charge (Grad MS), Annex E) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(v)(Particle charge (Grad SS-1), Annex E) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(v)(Particle charge (Grad SS-2), Annex E) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 1(Coating ability and water resistance:
Coating, dry aggregate (Grade RS-1) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 1(Coating ability and water resistance:
Coating, dry aggregate (Grade RS-2) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 1(Coating ability and water resistance:
Coating, dry aggregate (Grade MS) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 1(Coating ability and water resistance:
Coating, dry aggregate (Grade SS-1) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 1(Coating ability and water resistance:
Coating, dry aggregate (Grade SS-2) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 2(Coating ability and water resistance:
Coating, after spraying (Grade RS-1) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 2(Coating ability and water resistance:
Coating, after spraying (Grade RS-2) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 2(Coating ability and water resistance:
Coating, after spraying (Grade MS) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 2(Coating ability and water resistance:
Coating, after spraying (Grade SS-1) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 2(Coating ability and water resistance:
Coating, after spraying (Grade SS-2) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 3(Coating ability and water resistance:
Coating, wet aggregate (Grade RS-1) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 3(Coating ability and water resistance:
Coating, wet aggregate (Grade RS-2) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 3(Coating ability and water resistance:
Coating, wet aggregate (Grade MS) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 3(Coating ability and water resistance:
Coating, wet aggregate (Grade SS-1) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 3(Coating ability and water resistance:
Coating, wet aggregate (Grade SS-2) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 4(Coating ability and water resistance:
Coating, After Spraying (Grade RS-1) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 4(Coating ability and water resistance:
Coating, After Spraying (Grade RS-2) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 4(Coating ability and water resistance:
Coating, After Spraying (Grade MS) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 4(Coating ability and water resistance:
Coating, After Spraying (Grade SS-1) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vi) 4(Coating ability and water resistance:
Coating, After Spraying (Grade SS-2) Annex F) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vii)(Stability to mixing with cement (Grade RS-1) Annex G) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vii)(Stability to mixing with cement (Grade RS-2) Annex G) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vii)(Stability to mixing with cement (Grade MS) Annex G) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vii)(Stability to mixing with cement (Grade SS-1) Annex G) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(vii)(Stability to mixing with cement (Grade SS-2) Annex G) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(viii)(Miscibility with water (Grade RS-1) Annex H) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(viii)(Miscibility with water (Grade RS-2) Annex H) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(viii)(Miscibility with water (Grade MS) Annex H) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(viii)(Miscibility with water (Grade SS-1) Annex H) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(viii)(Miscibility with water (Grade SS-2) Annex H) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 1(Tests on residue: Residue by evaporation (Grade RS-1) Annex J) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 1(Tests on residue: Residue by evaporation (Grade RS-2) Annex J) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 1(Tests on residue: Residue by evaporation (Grade MS) Annex J) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 1(Tests on residue: Residue by evaporation (Grade SS-1) Annex J) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 1(Tests on residue: Residue by evaporation (Grade SS-2) Annex J) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 2(Tests on residue: Penetration (Grade RS-1) IS 1203) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 2(Tests on residue: Penetration (Grade RS-2) IS 1203) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 2(Tests on residue: Penetration (Grade MS) IS 1203) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 2(Tests on residue: Penetration (Grade SS-1) IS 1203) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 2(Tests on residue: Penetration (Grade SS-2) IS 1203) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 3(Tests on residue: Ductility (Grade RS-1) IS 1208) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 3(Tests on residue: Ductility (Grade RS-2) IS 1208) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 3(Tests on residue: Ductility (Grade MS) IS 1208) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 3(Tests on residue: Ductility (Grade SS-1) IS 1208) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 3(Tests on residue: Ductility (Grade SS-2) IS 1208) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 4(Tests on residue: Solubility I tricholoethylne,
(Grade RS-1) IS 1216) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 4(Tests on residue: Solubility I tricholoethylne,
(Grade RS-2) IS 1216) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 4(Tests on residue: Solubility I tricholoethylne,
(Grade MS) IS 1216) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 4(Tests on residue: Solubility I tricholoethylne,
(Grade SS-1) IS 1216) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(ix) 4(Tests on residue: Solubility I tricholoethylne,
(Grade SS-2) IS 1216) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 1(Distillation in percent volume of distillate recovered at 360°C (Grade RS-1)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 1(Distillation in percent volume of distillate recovered at 360°C (Grade RS-2)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 1(Distillation in percent volume of distillate recovered at 360°C (Grade MS)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 1(Distillation in percent volume of distillate recovered at 360°C (SS-1)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 1(Distillation in percent volume of distillate recovered at 360°C (Grade SS-2)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 2(Distillation in percent volume of distillate recovered at 360°C (Grade RS-1)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 2(Distillation in percent volume of distillate recovered at 360°C (Grade RS-2)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 2(Distillation in percent volume of distillate recovered at 360°C (Grade MS)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 2(Distillation in percent volume of distillate recovered at 360°C (SS-1)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 2(Distillation in percent volume of distillate recovered at 360°C (Grade SS-2)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 3(Distillation in percent volume of distillate recovered at 360°C (Grade RS-1)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 3(Distillation in percent volume of distillate recovered at 360°C (Grade RS-2)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 3(Distillation in percent volume of distillate recovered at 360°C (Grade MS)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 3(Distillation in percent volume of distillate recovered at 360°C (SS-1)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 3(Distillation in percent volume of distillate recovered at 360°C (Grade SS-2)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 4(Distillation in percent volume of distillate recovered at 360°C (Grade RS-1)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 4(Distillation in percent volume of distillate recovered at 360°C (Grade RS-2)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 4(Distillation in percent volume of distillate recovered at 360°C (Grade MS)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 4(Distillation in percent volume of distillate recovered at 360°C (SS-1)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 4(Distillation in percent volume of distillate recovered at 360°C (Grade SS-2)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 5(Distillation in percent volume of distillate recovered at 360°C (Grade RS-1)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 5(Distillation in percent volume of distillate recovered at 360°C (Grade RS-2)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 5(Distillation in percent volume of distillate recovered at 360°C (Grade MS)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 5(Distillation in percent volume of distillate recovered at 360°C (SS-1)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(x) 5(Distillation in percent volume of distillate recovered at 360°C (Grade SS-2)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(xi)(Water content (Grade RS-1)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(xi)(Water content (Grade RS-2)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(xi)(Water content (Grade MS)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(xi)(Water content (Grade SS-1)) |
- |
- |
|
- |
| 6.6.2 Table-1; 1(xi)(Water content (Grade SS-2)) |
- |
- |
|
- |
|
04 Dec, 2028 |
- Included w.e.f. 06-07-2023. |
| 10447 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 14333 (2022) |
Polyethylene Pipes for Sewerage and Industrial Chemicals and Effluent � Specification (First Revision) |
- |
52625 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2.1,T2("Base Density
(At 27°C Temp.)-IS 7328:2020 ") |
- |
1125 |
|
- |
| 5.2.1,T2(Melt Flow Rate (At 190°C /5kg)-IS 2530:1963) |
- |
1100 |
|
- |
| 5.2.1,T2(Thermal Stability(Oxidation Induction Time)-IS 4984:2016(Annexure-B)) |
- |
2200 |
|
- |
| 5.2.1,T2("Volatile Matter- IS 4984:2016
(Annexure-C)") |
- |
700 |
|
- |
| 5.2.1,T2("Water Content-IS 4984:2016
(Annexure-D)") |
- |
700 |
|
- |
| 5.3(Ash content- Any Method) |
- |
950 |
|
- |
| 5.3(Loading of Carbon Black - IS 2530:1963) |
- |
925 |
|
- |
| 5.3(Density of Higher olefin - IS 7328:2020) |
- |
500 |
|
- |
| 5.3(Toluene extract - Any Method) |
- |
900 |
|
- |
| 5.3("Maximum volatile matter -IS 4984:2016
(Annexure-C)") |
- |
700 |
|
- |
| 5.3(Carbon black particle size - Any Method) |
- |
3000 |
|
- |
| 6.2(Colour- IS 14333-2022) |
- |
250 |
|
- |
| 7.1(Visual Appearance- IS 14333-2022) |
- |
300 |
|
- |
| 7.2(Length- IS 14333-2022) |
- |
250 |
|
- |
| 7.4,T3 of IS 4984(Outside Diameter-IS 4984-2016) |
- |
500 |
|
- |
| 7.4,T4 of IS 4984(wall Thickness-IS 4984-2016) |
- |
0 |
|
- |
| 7.4,T3 of IS 4984(Ovality-IS 4984-2016) |
- |
0 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 27 oC , Test Period - 100 hrs.-IS 4984-2016 (Annexure-E)) |
- |
4000 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
1600 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 165 hrs.-IS 4984-2016 (Annexure-E)) |
- |
4800 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 1000 hrs.-IS 4984-2016 (Annexure-E)) |
- |
11000 |
|
- |
| 8.1.2, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
1600 |
|
- |
| 8.2("Longitudinal Reversion Test - IS 4984-2016
(Annexure-F)") |
- |
900 |
|
- |
| 8.3(Carbon black content- IS 2530-1963) |
- |
925 |
|
- |
| 8.3(Carbon black content Dispersion- IS 2530-1963) |
- |
700 |
|
- |
| 8.4(Melt Flow rate(Temperature - 190oC,Mass 5kg)-IS 2530-1963) |
- |
1100 |
|
- |
| 8.5(Oxidation Induction Time -IS 4984:2016(Annexure-B)) |
- |
2200 |
|
- |
| 8.6(Density-IS 7328:2020) |
- |
500 |
|
- |
| 8.7("Tensile Strength for Butt Fusion - IS 4984-2016
(Annexure-G)") |
- |
1600 |
|
- |
| 8.8,T5("Tensile - IS 4984-2016
(Annexure-H)") |
- |
0 |
|
- |
| 8.8,T5("Elongation -IS 4984-2016
(Annexure-H)") |
- |
1600 |
|
- |
| 8.9(Slow Crack Growth Rate{Internal Pressure creep Rupture test, Temperature - 80±1 oC , Test Pressure – 0.80MPa, Test Period - 500 hrs.-IS 4984-2016 (Annexure-E &J)) |
- |
6000 |
|
- |
| 5.2.1,T2("Base Density
(At 27°C Temp.)-IS 7328:2020 ") |
- |
0 |
|
- |
| 5.2.1,T2(Melt Flow Rate (At 190°C /5kg)-IS 2530:1963) |
- |
0 |
|
- |
| 5.2.1,T2(Thermal Stability(Oxidation Induction Time)-IS 4984:2016(Annexure-B)) |
- |
0 |
|
- |
| 5.2.1,T2("Volatile Matter- IS 4984:2016
(Annexure-C)") |
- |
0 |
|
- |
| 5.2.1,T2("Water Content-IS 4984:2016
(Annexure-D)") |
- |
0 |
|
- |
| 5.3(Ash content- Any Method) |
- |
0 |
|
- |
| 5.3(Loading of Carbon Black - IS 2530:1963) |
- |
0 |
|
- |
| 5.3(Density of Higher olefin - IS 7328:2020) |
- |
0 |
|
- |
| 5.3(Toluene extract - Any Method) |
- |
0 |
|
- |
| 5.3("Maximum volatile matter -IS 4984:2016
(Annexure-C)") |
- |
0 |
|
- |
| 5.3(Carbon black particle size - Any Method) |
- |
0 |
|
- |
| 6.2(Colour- IS 14333-2022) |
- |
0 |
|
- |
| 7.1(Visual Appearance- IS 14333-2022) |
- |
0 |
|
- |
| 7.2(Length- IS 14333-2022) |
- |
0 |
|
- |
| 7.4,T3 of IS 4984(Outside Diameter-IS 4984-2016) |
- |
0 |
|
- |
| 7.4,T4 of IS 4984(wall Thickness-IS 4984-2016) |
- |
0 |
|
- |
| 7.4,T3 of IS 4984(Ovality-IS 4984-2016) |
- |
0 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 27 oC , Test Period - 100 hrs.-IS 4984-2016 (Annexure-E)) |
- |
0 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
0 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 165 hrs.-IS 4984-2016 (Annexure-E)) |
- |
0 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 1000 hrs.-IS 4984-2016 (Annexure-E)) |
- |
0 |
|
- |
| 8.1.2, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
0 |
|
- |
| 8.2("Longitudinal Reversion Test - IS 4984-2016
(Annexure-F)") |
- |
0 |
|
- |
| 8.3(Carbon black content- IS 2530-1963) |
- |
0 |
|
- |
| 8.3(Carbon black content Dispersion- IS 2530-1963) |
- |
0 |
|
- |
| 8.4(Melt Flow rate(Temperature - 190oC,Mass 5kg)-IS 2530-1963) |
- |
0 |
|
- |
| 8.5(Oxidation Induction Time -IS 4984:2016(Annexure-B)) |
- |
0 |
|
- |
| 8.6(Density-IS 7328:2020) |
- |
0 |
|
- |
| 8.7("Tensile Strength for Butt Fusion - IS 4984-2016
(Annexure-G)") |
- |
0 |
|
- |
| 8.8,T5("Tensile - IS 4984-2016
(Annexure-H)") |
- |
0 |
|
- |
| 8.8,T5("Elongation -IS 4984-2016
(Annexure-H)") |
- |
0 |
|
- |
| 8.9(Slow Crack Growth Rate{Internal Pressure creep Rupture test, Temperature - 80±1 oC , Test Pressure – 0.80MPa, Test Period - 500 hrs.-IS 4984-2016 (Annexure-E &J)) |
- |
0 |
|
- |
| 5.2.1,T2("Base Density
(At 27°C Temp.)-IS 7328:2020 ") |
- |
0 |
|
- |
| 5.2.1,T2(Melt Flow Rate (At 190°C /5kg)-IS 2530:1963) |
- |
0 |
|
- |
| 5.2.1,T2(Thermal Stability(Oxidation Induction Time)-IS 4984:2016(Annexure-B)) |
- |
0 |
|
- |
| 5.2.1,T2("Volatile Matter- IS 4984:2016
(Annexure-C)") |
- |
0 |
|
- |
| 5.2.1,T2("Water Content-IS 4984:2016
(Annexure-D)") |
- |
0 |
|
- |
| 5.3(Ash content- Any Method) |
- |
0 |
|
- |
| 5.3(Loading of Carbon Black - IS 2530:1963) |
- |
0 |
|
- |
| 5.3(Density of Higher olefin - IS 7328:2020) |
- |
0 |
|
- |
| 5.3("Maximum volatile matter -IS 4984:2016
(Annexure-C)") |
- |
0 |
|
- |
| 6.2(Colour- IS 14333-2022) |
- |
0 |
|
- |
| 7.1(Visual Appearance- IS 14333-2022) |
- |
0 |
|
- |
| 7.2(Length- IS 14333-2022) |
- |
0 |
|
- |
| 7.4,T3 of IS 4984(Outside Diameter-IS 4984-2016) |
- |
0 |
|
- |
| 7.4,T4 of IS 4984(wall Thickness-IS 4984-2016) |
- |
0 |
|
- |
| 7.4,T3 of IS 4984(Ovality-IS 4984-2016) |
- |
0 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 27 oC , Test Period - 100 hrs.-IS 4984-2016 (Annexure-E)) |
- |
0 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
0 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 165 hrs.-IS 4984-2016 (Annexure-E)) |
- |
0 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 1000 hrs.-IS 4984-2016 (Annexure-E)) |
- |
0 |
|
- |
| 8.1.2, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
0 |
|
- |
| 8.2("Longitudinal Reversion Test - IS 4984-2016
(Annexure-F)") |
- |
0 |
|
- |
| 8.3(Carbon black content- IS 2530-1963) |
- |
0 |
|
- |
| 8.3(Carbon black content Dispersion- IS 2530-1963) |
- |
0 |
|
- |
| 8.4(Melt Flow rate(Temperature - 190oC,Mass 5kg)-IS 2530-1963) |
- |
0 |
|
- |
| 8.5(Oxidation Induction Time -IS 4984:2016(Annexure-B)) |
- |
0 |
|
- |
| 8.6(Density-IS 7328:2020) |
- |
0 |
|
- |
| 8.7("Tensile Strength for Butt Fusion - IS 4984-2016
(Annexure-G)") |
- |
0 |
|
- |
| 8.8,T5("Tensile - IS 4984-2016
(Annexure-H)") |
- |
0 |
|
- |
| 8.8,T5("Elongation -IS 4984-2016
(Annexure-H)") |
- |
0 |
|
- |
| 8.9(Slow Crack Growth Rate{Internal Pressure creep Rupture test, Temperature - 80±1 oC , Test Pressure – 0.80MPa, Test Period - 500 hrs.-IS 4984-2016 (Annexure-E &J)) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f. 28-06-2023. |
| 10448 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 11329 (2018) |
Finned type heat exchanger for room air conditioner (First Revision) |
- |
218000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(CLASSIFICATION AND NOMENCLATURE) |
- |
10000 |
|
- |
| 5(MATERIALS) |
- |
25000 |
|
- |
| 6(QUALITY REQUIREMENTS) |
- |
30000 |
|
- |
| 7(TESTING) |
- |
240000 |
|
- |
| 7.1("Permissible Assembly Contamination
Specification") |
- |
60000 |
|
- |
| 7.1.1(Internal Contamination) |
- |
60000 |
|
- |
| 7.2(Pressure Test for Assembly Tightness) |
- |
60000 |
|
- |
| 7.2.1(Water Leak Test) |
- |
60000 |
|
- |
| 7.3(Test for Mechanical Strength) |
- |
60000 |
|
- |
| 7.3.1(Burst Test) |
- |
60000 |
|
- |
| 7.4(Test for Corrosion Resistance) |
- |
60000 |
|
- |
| 8(MARKING) |
- |
2000 |
|
- |
| 9() |
- |
240000 |
|
- |
|
14 Nov, 2027 |
- - |
| 10449 |
ABSOLUTE TESTING SERVICES, FARIDABAD
| 8174526
| IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
2000 |
|
- |
| 8(Protection against accidental contact with live parts) |
- |
2000 |
|
- |
| 9(Terminals) |
- |
2000 |
|
- |
| 10(PROVISION FOR EARTHING) |
- |
2000 |
|
- |
| 11(MOISTURE RESISTANCE) |
- |
2000 |
|
- |
| 12(Electric Strength) |
- |
2000 |
|
- |
| 13(Thermal endurance test for winding of ballasts) |
- |
2000 |
|
- |
| 14(Fault conditions) |
- |
2000 |
|
- |
| 15(Transformer heating) |
- |
2000 |
|
- |
| 16(Construction) |
- |
2000 |
|
- |
| 17(Creepage distance and clearances) |
- |
2000 |
|
- |
| 18(Screws, current carrying parts and connections) |
- |
2000 |
|
- |
| 19(Resistance to heat, fire and tracking) |
- |
2000 |
|
- |
| 20(Resistance to corrosion) |
- |
2000 |
|
- |
|
13 Nov, 2026 |
- - |
| 10450 |
THE SOUTH INDIA TEXTILE RESEARCH ASSOCIATION (SITRA), COIMBATORE
| 6165234
| IS 17265 (2022) |
Textiles - 100 Percent polyester spun grey and white yarns - Specification (first revision) |
- |
35580 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2.1(Microscopic and dissolution test (IS 667)) |
- |
700 |
|
- |
| 5.2.1(Melting Point (16481)) |
- |
1700 |
|
By using Differential Scanning Calorimeter |
| 6 & Table 3(Mean linear density(Count) (IS 1315)) |
- |
250 |
|
- |
| 6 & Table 3(Twist per meter (IS 832 Part-1 & 2)) |
- |
340 |
|
- |
| 6 & Table 3(Single Yarn tenacity (RKM) (IS 1670)) |
- |
530 |
|
- |
| 6 & Table 3(Elongation (IS 1670)) |
- |
0 |
|
Included in Tenacity test rate |
| 6 & Table 3(Coungth Strength Product (CSP) (IS 1671)) |
- |
360 |
|
- |
| 6 & Table 3(Yarn Hairiness index (IS 17265)) |
- |
400 |
|
- |
| 6 & Table 3(Whiteness Index of polyester spun yarn (IS17263)) |
- |
400 |
|
- |
| 6 & Table 4(Moisture regain (IS 17265)) |
- |
350 |
|
- |
| 6 & Table 4(Water soluble matter (IS 3456)) |
- |
300 |
|
- |
| 6 & Table 4(Phosphorus content (IS 17265)) |
- |
1000 |
|
- |
| 6 & Table 4(Anti-microbial activity value (IS/ISO 20743)) |
- |
2850 |
|
- |
| 6 & Table 4(Wettability of woven or knitted fabrics (about 150 gsm) made from the yarn (IS 2349)) |
- |
400 |
|
- |
| 6 & Table 4(Wicking characteristic of woven or knitted fabrics (about 150 gsm) made from the yarn (IS 17265)) |
- |
500 |
|
- |
| 6.8 & Table 8(Free and releasable formaldehyde (IS 14563 (Part 1) and IS 14563 (Part 2))) |
- |
1500 |
|
- |
| 6.8 & Table 8(Mercury (IS 15651)) |
- |
4500 |
|
- |
| 6.8 & Table 8(Chromium III (IS 15651)) |
- |
0 |
|
Included in the test rate for Mercury. By ICP-MS. |
| 6.8 & Table 8(Lead (IS 15651)) |
- |
0 |
|
Included in the test rate for Mercury. By ICP-MS. |
| 6.8 & Table 8(Cadmium) |
- |
0 |
|
Included in the test rate for Mercury. By ICP-MS. |
| 6.8 & Table 8(Copper (IS 15651)) |
- |
0 |
|
Included in the test rate for Mercury. By ICP-MS. |
| 6.8 & Table 8(Antimony (IS 15651)) |
- |
0 |
|
Included in the test rate for Mercury. By ICP-MS. |
| 6.8 & Table 8(Pentachlorophenol (IS 15651)) |
- |
2500 |
|
- |
| 6.8 & Table 8(Pesticides (sum parameter) (IS 15651)) |
- |
5000 |
|
- |
| 6.8 & Table 8(Banned pesticides (IS 15651)) |
- |
0 |
|
Included in Pesticides (Sum parameters) |
| 6.8 & Table 8(Banned azo colourants (arylamines) (IS 15570)) |
- |
3000 |
|
- |
| 6.2.1(tenacity of multifold yarn including double yarn (IS 17265)) |
- |
530 |
|
- |
| 6.2.2(Resultant count of yarn and CV percentage (IS 1315)) |
- |
250 |
|
- |
| 6.4 & table 5(Yarn Unevenness and Yarn Imperfections) |
- |
400 |
|
- |
| 6.4 & table 5(U Percent) |
- |
0 |
|
Included in Yarn Unevenness and imperfections |
| 6.7 & Table 7(Colour Fastness Rating To Washing Change in colour (IS/ISO 105-C10)) |
- |
300 |
|
- |
| 6.7 & Table 7(Colour Fastness Rating To Washing Staining (IS/ISO 105-C10)) |
- |
0 |
|
- |
| 6.7 & Table 7(Colour Fastness Rating To Rubbing Dry (IS/ISO 105-X12)) |
- |
300 |
|
- |
| 6.7 & Table 7(Colour Fastness Rating To Rubbing Wet (IS/ISO 105-X12)) |
- |
0 |
|
- |
| 6.7 & Table 7(Colour Fastness Rating To Perspiration (acidic and alkaline) Change in colour (IS/ISO 105-E04)) |
- |
450 |
|
- |
| 6.7 & Table 7(Colour Fastness Rating To Perspiration (acidic and alkaline) Staining (IS/ISO 105-E04)) |
- |
0 |
|
- |
| 5.2.1(Microscopic and dissolution test (IS 667)) |
- |
0 |
|
Parameter repeated. |
| 5.2.1(Melting Point (16481)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 3(Mean linear density(Count) (IS 1315)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 3(Twist per meter (IS 832 Part-1 & 2)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 3(Single Yarn tenacity (RKM) (IS 1670)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 3(Elongation (IS 1670)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 3(Coungth Strength Product (CSP) (IS 1671)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 3(Yarn Hairiness index (IS 17265)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 3(Whiteness Index of polyester spun yarn (IS17263)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 4(Moisture regain (IS 17265)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 4(Water soluble matter (IS 3456)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 4(Phosphorus content (IS 17265)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 4(Anti-microbial activity value (IS/ISO 20743)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 4(Wettability of woven or knitted fabrics (about 150 gsm) made from the yarn (IS 2349)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 4(Wicking characteristic of woven or knitted fabrics (about 150 gsm) made from the yarn (IS 17265)) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Free and releasable formaldehyde (IS 14563 (Part 1) and IS 14563 (Part 2))) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Mercury (IS 15651)) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Chromium III (IS 15651)) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Lead (IS 15651)) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Cadmium) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Copper (IS 15651)) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Antimony (IS 15651)) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Pentachlorophenol (IS 15651)) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Pesticides (sum parameter) (IS 15651)) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Banned pesticides (IS 15651)) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Banned azo colourants (arylamines) (IS 15570)) |
- |
0 |
|
Parameter repeated. |
| 6.2.1(tenacity of multifold yarn including double yarn (IS 17265)) |
- |
0 |
|
Parameter repeated. |
| 6.2.2(Resultant count of yarn and CV percentage (IS 1315)) |
- |
0 |
|
Parameter repeated. |
| 6.4 & table 5(Yarn Unevenness and Yarn Imperfections) |
- |
0 |
|
Parameter repeated. |
| 6.4 & table 5(U Percent) |
- |
0 |
|
Parameter repeated. |
| 6.7 & Table 7(Colour Fastness Rating To Washing Change in colour (IS/ISO 105-C10)) |
- |
0 |
|
Parameter repeated. |
| 6.7 & Table 7(Colour Fastness Rating To Washing Staining (IS/ISO 105-C10)) |
- |
0 |
|
Parameter repeated. |
| 6.7 & Table 7(Colour Fastness Rating To Rubbing Dry (IS/ISO 105-X12)) |
- |
0 |
|
Parameter repeated. |
| 6.7 & Table 7(Colour Fastness Rating To Rubbing Wet (IS/ISO 105-X12)) |
- |
0 |
|
Parameter repeated. |
| 6.7 & Table 7(Colour Fastness Rating To Perspiration (acidic and alkaline) Change in colour (IS/ISO 105-E04)) |
- |
0 |
|
Parameter repeated. |
| 6.7 & Table 7(Colour Fastness Rating To Perspiration (acidic and alkaline) Staining (IS/ISO 105-E04)) |
- |
0 |
|
Parameter repeated. |
| 6.1 Table 7(Colour Fastness to light) |
- |
1200 |
|
Upto BWS 3 rating |
| 6 & Table 4(Isophthalic acid (IPA) content (IS 16481)) |
- |
4000 |
|
- |
| 6.3(Freedom from Defects (IS 17265)) |
- |
0 |
|
Included |
| 5.2.1(Microscopic and dissolution test (IS 667)) |
- |
0 |
|
Parameter repeated. |
| 5.2.1(Melting Point (16481)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 3(Mean linear density(Count) (IS 1315)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 3(Twist per meter (IS 832 Part-1 & 2)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 3(Single Yarn tenacity (RKM) (IS 1670)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 3(Elongation (IS 1670)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 3(Coungth Strength Product (CSP) (IS 1671)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 3(Yarn Hairiness index (IS 17265)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 3(Whiteness Index of polyester spun yarn (IS17263)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 4(Moisture regain (IS 17265)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 4(Water soluble matter (IS 3456)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 4(Phosphorus content (IS 17265)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 4(Anti-microbial activity value (IS/ISO 20743)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 4(Wettability of woven or knitted fabrics (about 150 gsm) made from the yarn (IS 2349)) |
- |
0 |
|
Parameter repeated. |
| 6 & Table 4(Wicking characteristic of woven or knitted fabrics (about 150 gsm) made from the yarn (IS 17265)) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Free and releasable formaldehyde (IS 14563 (Part 1) and IS 14563 (Part 2))) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Mercury (IS 15651)) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Chromium III (IS 15651)) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Lead (IS 15651)) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Cadmium) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Copper (IS 15651)) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Antimony (IS 15651)) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Pentachlorophenol (IS 15651)) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Pesticides (sum parameter) (IS 15651)) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Banned pesticides (IS 15651)) |
- |
0 |
|
Parameter repeated. |
| 6.8 & Table 8(Banned azo colourants (arylamines) (IS 15570)) |
- |
0 |
|
Parameter repeated. |
| 6.2.1(tenacity of multifold yarn including double yarn (IS 17265)) |
- |
0 |
|
Parameter repeated. |
| 6.2.2(Resultant count of yarn and CV percentage (IS 1315)) |
- |
0 |
|
Parameter repeated. |
| 6.4 & table 5(Yarn Unevenness and Yarn Imperfections) |
- |
0 |
|
Parameter repeated. |
| 6.4 & table 5(U Percent) |
- |
0 |
|
Parameter repeated. |
| 6.7 & Table 7(Colour Fastness Rating To Washing Change in colour (IS/ISO 105-C10)) |
- |
0 |
|
Parameter repeated. |
| 6.7 & Table 7(Colour Fastness Rating To Washing Staining (IS/ISO 105-C10)) |
- |
0 |
|
Parameter repeated. |
| 6.7 & Table 7(Colour Fastness Rating To Rubbing Dry (IS/ISO 105-X12)) |
- |
0 |
|
Parameter repeated. |
| 6.7 & Table 7(Colour Fastness Rating To Rubbing Wet (IS/ISO 105-X12)) |
- |
0 |
|
Parameter repeated. |
| 6.7 & Table 7(Colour Fastness Rating To Perspiration (acidic and alkaline) Change in colour (IS/ISO 105-E04)) |
- |
0 |
|
Parameter repeated. |
| 6.7 & Table 7(Colour Fastness Rating To Perspiration (acidic and alkaline) Staining (IS/ISO 105-E04)) |
- |
0 |
|
Parameter repeated. |
| 6.1 Table 7(Colour Fastness to light) |
- |
1200 |
|
Upto BWS 3 |
| 6 & Table 4(Isophthalic acid (IPA) content (IS 16481)) |
- |
4000 |
|
By instrumental analysis |
| 6.3(Freedom from Defects (IS 17265)) |
- |
0 |
|
Included |
|
- |
- - |
| 10451 |
BIS, Central Laboratory (CL)
| None
| IS 2791 (2022) |
SOLUBLE COFFEE POWDER - SPECIFICATION (FOURTH REVISION OF IS 2791) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.3, Table 1 (i) (Moisture -IS 16029) |
- |
|
|
|
| 3.6.2.1 (Free from infestation - IS 2791) |
- |
|
|
|
| 3.3, Table 1 (iii) (Total Ash(ODB)-IS 2791) |
- |
|
|
|
| 3.3, Table 1 (v) (Solubility in cold water at 16 ± 2°C- IS 2791) |
- |
|
|
|
| 3.3, Table 1 (iv) (Solubility in boiling water-IS 2791) |
- |
|
|
|
| 3.1 (Description-2791) |
- |
|
|
|
| 3.3, Table 1 (iii) (Total Ash(ODB)-IS 2791) |
- |
|
|
|
|
- |
- 500 gm x 3
Excluding 1-Caffeine content 2- Copper content |
| 10452 |
ABSOLUTE TESTING SERVICES, FARIDABAD
| 8174526
| IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
2000 |
|
- |
| 6(Interchangeability) |
- |
2000 |
|
- |
| 7(Protection against accidental contact with live parts) |
- |
2000 |
|
- |
| 8(Insulation Resistance and Electric Strength) |
- |
2000 |
|
- |
| 9(MECHANICAL STRENGTH) |
- |
2000 |
|
- |
| 10(cap temperature) |
- |
2000 |
|
- |
| 11(Resistance to Heat) |
- |
2000 |
|
- |
| 12(Resistance to Flame and Ignition) |
- |
2000 |
|
- |
| 13(Fault conditions) |
- |
2000 |
|
- |
| 14(Creepage distance and clearances) |
- |
2000 |
|
- |
| 15(Selection of lamps for tests (Sampling)) |
- |
2000 |
|
- |
| 16(Condition of compliance) |
- |
2000 |
|
- |
| 17(Tests) |
- |
2000 |
|
- |
| Annex A(Ovreview of systems composed of LED modules and control gear) |
- |
2000 |
|
- |
| Annex B(Lamps with operating position limitations) |
- |
2000 |
|
- |
|
13 Nov, 2026 |
- - |
| 10453 |
ABSOLUTE TESTING SERVICES, FARIDABAD
| 8174526
| IS 16046 : Part 2 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 2 Lithium Systems ( Second Revision ) |
- |
80000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
2500 |
|
- |
| 5(General Safety Considerations) |
- |
2500 |
|
- |
| 5.1(General) |
- |
2500 |
|
- |
| 5.2(Insulation and Wiring) |
- |
2500 |
|
- |
| 5.3(Venting) |
- |
2500 |
|
- |
| 5.4(Temperature, Voltage and Current Management) |
- |
2500 |
|
- |
| 5.5(Terminal Contacts) |
- |
2500 |
|
- |
| 5.6(Assembly of Cells into batteries) |
- |
2500 |
|
- |
| 5.7(Quality Plan) |
- |
2500 |
|
- |
| 5.8(Battery Safety Components) |
- |
2500 |
|
- |
| 6(Type Test and Sample Size) |
- |
2500 |
|
- |
| 7(Specific requirements and tests) |
- |
2500 |
|
- |
| 7.1(Charging procedure for test purposes) |
- |
2500 |
|
- |
| 7.2(Intended Use) |
- |
2500 |
|
- |
| 7.3(Reasonably foreseeable misuse) |
- |
2500 |
|
- |
| 8(Information for safety) |
- |
2500 |
|
- |
| 8.1(General) |
- |
2500 |
|
- |
| 8.2(Small Cell and battery safety information) |
- |
2500 |
|
- |
| 9(Marking) |
- |
2500 |
|
- |
| 9.1(Cell Marking) |
- |
2500 |
|
- |
| 9.2(Battery Marking) |
- |
2500 |
|
- |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
2500 |
|
- |
| 9.4(Other information) |
- |
2500 |
|
- |
| 10(Packaging) |
- |
2500 |
|
- |
|
13 Nov, 2026 |
- - |
| 10454 |
GLOBAL COMPLIANCE LABORATORY INDIA, GHAZIABAD
| 5172706
| IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
Class - 1 and 2 |
64000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
2000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
| 10.1(Power input) |
- |
3000 |
|
- |
| 10.2(Current input) |
- |
3000 |
|
- |
| 11.1(General) |
- |
3000 |
|
- |
| 11.2(General) |
- |
3000 |
|
- |
| 11.3(Heating) |
- |
2000 |
|
- |
| 13.1(General) |
- |
2000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
2000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
2000 |
|
- |
| 15.0(General) |
- |
2000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
2000 |
|
- |
| 15.2(Spillage Test) |
- |
2000 |
|
- |
| 15.3(Humidity Test) |
- |
2000 |
|
- |
| 16.0(General) |
- |
800 |
|
- |
| 16.1(General) |
- |
800 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
800 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
600 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
2000 |
|
- |
| 19(Abnormal Operation) |
- |
2000 |
|
- |
| 20(Stability test) |
- |
1000 |
|
- |
| 21(Mechanical Strength Test) |
- |
3000 |
|
- |
| 22(Construction verification related test) |
- |
2000 |
|
- |
| 23(General) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
2000 |
|
- |
| 26(Terminals for external conductors) |
- |
2000 |
|
- |
| 27(Provision for earthing) |
- |
2000 |
|
- |
| 28(Screw test and connections) |
- |
2000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
3000 |
|
- |
| 30.1(Ball pressure test) |
- |
700 |
|
- |
| 30.2(Glow Wire Test) |
- |
700 |
|
- |
| 30.2(Needle Flame Test) |
- |
600 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
1000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
- |
| 11.4(Heating appliances) |
- |
2000 |
|
- |
| 11.5(Motor-operated appliances) |
- |
2000 |
|
- |
| 11.6(Combined appliances) |
- |
2000 |
|
- |
| 11.7(Duration corresponding) |
- |
2000 |
|
- |
| 11.8(Temperature rise) |
- |
2000 |
|
- |
|
20 Jun, 2026 |
- Exclusion: Cl. 19.11.4.1 (Electrostatic discharges), Cl. 19.11.4.2 (Radiated fields), Cl. 19.11.4.3 (Fast transient bursts), Cl. 19.11.4.4 (Surge immunity test), Cl. 19.11.4.5 (Immunity to conducted discharges), Cl. 19.11.4.6 (Class 3 Voltage dips and interruptions), Cl. 19.11.4.7 (Harmonics), Cl. 24 (Components), Cl. 32 (Radiation Toxicity and Similar Hazards).
"(1)Cooking ranges, hobs, ovens and similar appliances, (2)Commercial Dispensing Appliances and Vending Machines, (3) spin extractors
(For testing charges please refer relevant Part 2 standard in LIMS)" |
| 10455 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 3443 (1980) |
Crane Rail Sections - |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-A) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-B) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-C) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-D) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-E) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-F) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-G) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-H) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-R4) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-R5) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-R6) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-R7) |
- |
|
|
|
| 9.1 (Freedom from defects) |
- |
|
|
|
| 9.2 (Freedom from defects- Asymmetry in the flange) |
- |
|
|
|
| 9.2 (Freedom from defects- Asymmetry in the head) |
- |
|
|
|
| Cl. 4, Table 1 (Chemical Composition - Carbon) |
- |
|
|
|
| Cl. 4, Table 1 (Chemical Composition - Manganese) |
- |
|
|
|
| Cl. 4, Table 1 (Chemical Composition - Silicon) |
- |
|
|
|
| Cl. 4, Table 1 (Chemical Composition - Sulphur) |
- |
|
|
|
| Cl. 4, Table 1 (Chemical Composition - Phosphorous) |
- |
|
|
|
|
- |
- Complete |
| 10456 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
- |
37300 View breakup
Class I & II Product : (AMPLIFIERS WITH INPUT POWER 2000W AND ABOVE, ELECTRONIC GAMES (VIDEO), ELECTRONIC MUSICAL SYSTEMS WITH INPUT POWER 200W AND ABOVE, OPTICAL DISC PLAYERS WITH BUILT IN AMPLIFIERS OF INPUT POWER 200W AND ABOVE, PLASMA/LCD/LED TELEVISIONS OF SCREEN SIZE 32"; AND ABOVE, POWER ADAPTORS FOR AUDIO, VIDEO & SIMILAR ELECTRONIC APPARATUS, PLASMA/ LCD/LED TELEVISION OF SCREEN SIZE UP-TO 32, WIRELESS HEADPHONE AND EARPHONE, ELECTRONIC MUSICAL SYSTEM WITH INPUT POWER BELOW 200 WATTS, TELEVISION OTHER THAN PLASMA/ LCD/LED TVS, WIRELESS MICROPHONE, VIDEO CAMERA, WEBCAM (FINISHED PRODUCT), SMART SPEAKERS (WITH AND WITHOUT DISPLAY), BLUETOOTH SPEAKERS)- Rs. 45000/-
Class III Product : (WIRELESS HEADPHONE AND EARPHONE, WIRELESS MICROPHONE, VIDEO CAMERA, WEBCAM (FINISHED PRODUCT), SMART SPEAKERS (WITH AND WITHOUT DISPLAY), BLUETOOTH SPEAKERS)- Rs. 30000/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking and instructions) |
- |
1000 |
|
- |
| 7(Heating under normal operating conditions) |
- |
1000 |
|
- |
| 8(Constructional requirements with regard to the protection against electric shock) |
- |
500 |
|
- |
| 10(Insulation requirements) |
- |
500 |
|
- |
| 11(Fault conditions) |
- |
1000 |
|
- |
| 12(Mechanical strength) |
- |
1000 |
|
- |
| 13(CLEARANCES and CREEPAGE DISTANCES) |
- |
1000 |
|
- |
| 15(TERMINALS) |
- |
1000 |
|
- |
| 16(External flexible cords) |
- |
1000 |
|
- |
| 17(Electrical connections and mechanical fixings) |
- |
1000 |
|
- |
| 19(Stability and mechanical hazards) |
- |
1000 |
|
- |
| 4(General test conditions) |
- |
100 |
|
- |
| 14(Components) |
- |
100 |
|
- |
| 9(Electric shock hazard under normal operating conditions) |
- |
100 |
|
- |
| Cl.5.1 of Cl.5(General requirements) |
- |
100 |
|
- |
| Cl.5.1-i) of Cl.5(Comprehensible and easily discernible) |
- |
100 |
|
- |
| Cl.5.1-ii) of Cl.5(Permanent durability against water and petroleum spirit) |
- |
100 |
|
- |
| Cl.5.2 of Cl.5(Identification and supply ratings) |
- |
100 |
|
- |
| Cl.5.2 a) of Cl.5(Identification, maker) |
- |
100 |
|
- |
| Cl.5.2 b) of Cl.5(Model number or type reference) |
- |
100 |
|
- |
| Cl.5.2 d) of Cl.5(Nature of supply) |
- |
100 |
|
- |
| Cl.5.2 e) of Cl.5(Rated supply voltage) |
- |
100 |
|
- |
| Cl.5.2 f) of Cl.5(Mains frequency if safety dependant) |
- |
100 |
|
- |
| Cl.5.2 g) of Cl.5(Rated current or power consumption for apparatus supplied by supply apparatus for general use, on apparatus or in instruction manual: Measured current or power consumption: Deviation % (max 10%):) |
- |
100 |
|
- |
| Cl.5.2 h) of Cl.5(Rated current or power consumption for apparatus intended for connection to an a.c. mains supply:Measured current or power consumption for Television set: Deviation % (max 10%):) |
- |
100 |
|
- |
| Cl.5.2 h)-i) of Cl.5(appliance coupler for Class I is used for Class II equipment with functional earth connection, the requirements of Clause 15 and Clause 16 related to Class I construction shall be applied up to the connecting point of the protective(earthing) conductor to the functional earth.) |
- |
100 |
|
- |
| Cl.5.2 h)-ii) of Cl.5(Graphical symbols placed on the apparatus, whether required by this standard or not, shall be in accordance with IEC 60417 or ISO 3864-2 or ISO 7000, if available. In the absence of suitable symbols, the manufacturer may design specific graphical symbols.) |
- |
100 |
|
- |
| Cl.5.2 h)-iii) of Cl.5(Care shall be taken so that additional markings and instructions not required by this standard do not contradict the markings and instructions required by this standard . Symbols placed on the Equipment shall be explained in the user manual.) |
- |
100 |
|
- |
| Cl.5.3 of Cl.5(Terminals) |
- |
100 |
|
- |
| Cl.5.3a) of Cl.5(Earth terminal) |
- |
100 |
|
- |
| Cl.5.3b) of Cl.5(Hazardous live terminals) |
- |
100 |
|
- |
| Cl.5.3c) of Cl.5(Markings on supply output terminals) |
- |
100 |
|
- |
| Cl.5.4 of Cl.5(Caution marking) |
- |
100 |
|
- |
| Cl.5.4a) of Cl.5(Use of triangle with exclamation mark) |
- |
100 |
|
- |
| Cl.5.4b) of Cl.5(Marking on loudspeaker grille, IEC 60417-5036) |
- |
100 |
|
- |
| Cl.5.4c) of Cl.5(User-replaceable coin / button cell battery marking) |
- |
100 |
|
- |
| Cl.5.5 of Cl.5(Instructions) |
- |
100 |
|
- |
| Cl.5.5 of Cl.5(Instructions) |
- |
100 |
|
- |
| Cl.5.5 of Cl.5(Instructions) |
- |
100 |
|
- |
| Cl.5.5.1 of Cl.5.5(Safety relevant information) |
- |
100 |
|
- |
| Cl.5.5.2 b) of Cl.5.5(Hazardous live terminals, instructions for wiring) |
- |
100 |
|
- |
| Cl.5.5.2 c) of Cl.5.5(Instructions for replacing lithium battery) |
- |
100 |
|
- |
| Cl.5.5.2 d) of Cl.5.5(Class I earth connection warning) |
- |
100 |
|
- |
| Cl.5.5.2 e) of Cl.5.5(Instructions for multimedia system connection) |
- |
100 |
|
- |
| Cl.5.5.2 f) of Cl.5.5(Special stability warning for attachment of the apparatus to the floor/wall) |
- |
100 |
|
- |
| Cl.5.5.2 g) of Cl.5.5(Warning: battery exposure to heat) |
- |
100 |
|
- |
| Cl.5.5.2 h) of Cl.5.5(Warning: protective film on CRT face) |
- |
100 |
|
- |
| Cl.5.5.2 i) of Cl.5.5("Warning: Non-floor standing TV
>7kg") |
- |
100 |
|
- |
| Cl.5.5.2 j) of Cl.5.5("Warning: User replaceable coin
/ button cell battery") |
- |
100 |
|
- |
| Cl.5.5.3 (a-b) of Cl.5.5(Disconnect device: plug/coupler or all-pole mains switch location, accessibility and markings) |
- |
100 |
|
- |
| Cl.5.5.3 c) of Cl.5.5(Instructions for permanently connected equipment) |
- |
100 |
|
- |
| Cl.5.5.3 c) i) of Cl.5.5(Marking, signal lamps or similar for completely disconnection from the mains) |
- |
100 |
|
- |
| Cl.7.1 of Cl.7(General) |
- |
100 |
|
- |
| "Cl.7.1.1 of Cl.7.1 Table-3"(Requirements) |
- |
100 |
|
- |
| "Cl.7.1.2 of Cl.7.1 Table-3"(Accessible parts) |
- |
100 |
|
- |
| "Cl.7.1.3 of Cl.7.1 Table-3"(Parts, other than windings and printed boards, providing electrical insulation) |
- |
100 |
|
- |
| "Cl.7.1.4 of Cl.7.1 Table-3"(Parts acting as a support or a mechanical barrier) |
- |
100 |
|
- |
| "Cl.7.1.5 of Cl.7.1 Table-3"(Windings) |
- |
100 |
|
- |
| "Cl.7.1.6 of Cl.7.1 Table-3"(Parts not subject to a limit under7.1.1 to 7.1.4) |
- |
100 |
|
- |
| Cl.7.2 of Cl.7(Softening temperature of insulating material supporting parts conductively connected to the mains carrying a current> 0.2 A, shall be at least 150ºC) |
- |
100 |
|
- |
| Cl.8.1 of Cl.8(Conductive parts covered by lacquer, paper, untreated textile oxide films and beads etc. considered to be bare*) |
- |
100 |
|
- |
| Cl.8.2 of Cl.8(No shock hazard when changing voltage setting device, fuse-links or handling drawers etc.) |
- |
100 |
|
- |
| Cl.8.3 of Cl.8(Insulation of hazardous live parts not provided by hygroscopic material) |
- |
100 |
|
- |
| Cl.8.4 of Cl.8(No risk of electric shock from accessible parts or from parts rendered accessible following the removal of a cover which can be removed by hand) |
- |
100 |
|
- |
| Cl.8.5 of Cl.8(Class I apparatus*) |
- |
100 |
|
- |
| Cl.8.5 i) of Cl.8(Basic insulation between hazardous live parts and earthed accessible parts *) |
- |
100 |
|
- |
| Cl.8.5 iv) of Cl.8(Protective earthing terminal *) |
- |
100 |
|
- |
| Cl.8.6 of Cl.8(Class II apparatus) |
- |
100 |
|
- |
| Cl.8.6 a) of Cl.8(Basic and supplementary insulation between hazardous live parts and accessible parts *) |
- |
100 |
|
- |
| Cl.8.6 b) of Cl.8(Reinforced insulation between hazardous live parts and accessible parts *) |
- |
100 |
|
- |
| Cl.8.8 of Cl.8(Insulation thickness and thin sheet materials) |
- |
100 |
|
- |
| Cl.8.8 i) of Cl.8(Basic or supplementary insulation > 0,4 mm (mm)*) |
- |
100 |
|
- |
| Cl.8.8 ii) of Cl.8(Reinforced insulation > 0,4 mm (mm) *) |
- |
100 |
|
- |
| Cl.8.8 iii) of Cl.8(Thin sheet material used inside the equipment) |
- |
100 |
|
- |
| Cl.8.8 iv) of Cl.8(Basic or supplementary insulation, atleast two layers, each meeting10.4) |
- |
100 |
|
- |
| Cl.8.8 v) of Cl.8(Basic or supplementary insulation, three layers any two of which meet10.4) |
- |
100 |
|
- |
| Cl.8.8 vi) of Cl.8(Reinforced insulation, two layers each of which meet 10.4) |
- |
100 |
|
- |
| Cl.8.9 of Cl.8(Adequate insulation between internal hazardous live conductors and accessible parts, or between internal hazardous live parts and conductors connected to accessible parts) |
- |
100 |
|
- |
| Cl.8.10 of Cl.8(Double insulation between accessible parts and conductors connected to the mains) |
- |
100 |
|
- |
| Cl.8.11 of Cl.8(Detaching of wires) |
- |
100 |
|
- |
| Cl.8.12 of Cl.8(Adequate fastening of windows, lenses, lamp covers etc. (pull test 20 N for 10 s)) |
- |
100 |
|
- |
| Cl.8.13 of Cl.8(Adequate fastening of windows, lenses, lamp covers etc. (pull test 20 N for 10 s)) |
- |
100 |
|
- |
| Cl.8.14 of Cl.8(No risk of damage to the insulation of internal wiring due to hot parts or sharp edges) |
- |
100 |
|
- |
| Cl.8.15 of Cl.8(Only special supply equipment can be used*) |
- |
100 |
|
- |
| Cl.8.18 of Cl.8(Disconnection from the mains) |
- |
100 |
|
- |
| Cl.8.18 i) of Cl.8(Disconnect device used in apparatus) |
- |
100 |
|
- |
| Cl.8.18 ii) of Cl.8(All-pole switch or circuit breaker with >3mm contact separation.) |
- |
100 |
|
- |
| Cl.8.18 iii) of Cl.8(Mains switch ON indication *) |
- |
100 |
|
- |
| Cl.8.19 of Cl.8(Switch not fitted in the mains cord *) |
- |
100 |
|
- |
| Cl.8.21 of Cl.8(Non-separable thin sheet material) |
- |
100 |
|
- |
| Cl.9.1.1 of Cl.9.1(Requirements) |
- |
100 |
|
- |
| Cl.9.1.1 i) of Cl.9.1(Accessible parts shall not be hazardous live) |
- |
100 |
|
- |
| Cl.9.1.1 ii) of Cl.9.1(Inaccessible terminals are not accessible or comply with relevant requirements) |
- |
100 |
|
- |
| Cl.9.1.1 iii) of Cl.9.1(For voltages >1000 V ac or >1500 V dc complies with clause 13.3.1 for basic insulation) |
- |
100 |
|
- |
| Cl.9.1.1.2 of Cl.9.1.1(Determination of hazardous live parts) |
- |
100 |
|
- |
| Cl.9.1.1.2 a) of Cl.9.1.1(Open circuit voltages) |
- |
100 |
|
- |
| Touch current measured from terminal devices using the network in annex D(Touch current measured from terminal devices using the network in annex D) |
- |
100 |
|
- |
| Cl.9.1.1.2 c) of Cl.9.1.1(The charge exceeds 45 μC) |
- |
100 |
|
- |
| Cl.9.1.1.2 d) of Cl.9.1.1(Energy of discharge not exceeding 350 mJ) |
- |
100 |
|
- |
| Cl.9.1.1.3 of Cl.9.1.1(Test with test finger and test probe) |
- |
100 |
|
- |
| Cl.9.1.2 of Cl.9.1(Shafts of operating knobs, handles, levers and the like) |
- |
100 |
|
- |
| Cl.9.1.3 of Cl.9.1(Openings ofthe enclosure) |
- |
100 |
|
- |
| Cl.9.1.4 of Cl.9.1(Terminals) |
- |
100 |
|
- |
| Cl.9.1.4 i) of Cl.9.1(Terminals) |
- |
100 |
|
- |
| Cl.9.1.4 ii) of Cl.9.1(Terminals) |
- |
100 |
|
- |
| Cl.9.1.5 of Cl.9.1(Pre-set controls) |
- |
100 |
|
- |
| Cl.9.1.6 of Cl.9.1(Withdrawal of the mains plug:) |
- |
100 |
|
- |
| Cl.9.1.6 i) of Cl.9.1(Withdrawal of the mains plug:) |
- |
100 |
|
- |
| Cl.9.1.6 ii) of Cl.9.1(Withdrawal of the mains plug:) |
- |
100 |
|
- |
| Cl.9.1.6 iii) of Cl.9.1(Withdrawal of the mains plug:) |
- |
100 |
|
- |
| Cl.9.1.7 of Cl.9.1(Resistance to external forces) |
- |
100 |
|
- |
| Cl.9.1.7 a) of Cl.9.1(Resistance to external forces) |
- |
100 |
|
- |
| Cl.9.1.7 b) of Cl.9.1(Resistance to external forces) |
- |
100 |
|
- |
| Cl.9.1.7 c) of Cl.9.1(Resistance to external forces) |
- |
100 |
|
- |
| Cl.9.2 of Cl.9(Removal of protective covers) |
- |
100 |
|
- |
| Cl.10.2 of Cl.10(Surge Test) |
- |
100 |
|
- |
| Cl.10.2 a) of Cl.10(Surge Test) |
- |
100 |
|
- |
| Cl.10.2 b) of Cl.10(Surge Test) |
- |
100 |
|
- |
| Cl.10.2 b) (i) of Cl.10(Surge Test) |
- |
100 |
|
- |
| Cl.10.4.2 ii) of Cl.10.4(Between parts separated by REINFORCED insulation) |
- |
100 |
|
- |
| Cl.10.2 b) (ii) of Cl.10(Surge Test) |
- |
100 |
|
- |
| Cl.10.2 b) (iii) of Cl.10(Surge Test) |
- |
100 |
|
- |
| Cl.10.3 of Cl.10(Humidity treatment) |
- |
100 |
|
- |
| Cl.10.4 of Cl.10(Insulation resistance and dielectric strength) |
- |
100 |
|
- |
| Cl.10.4.1 of Cl.10.4(Insulation of the insulating materials) |
- |
100 |
|
- |
| Cl.10.4.2 of Cl.10.4(Between parts of different polarity directly connected to the mains
Between parts of different polarity directly connected to the mains) |
- |
100 |
|
- |
| Cl.10.4.2 i) of Cl.10.4(Between parts separated by BASIC or SUPPLEMENTARY insulation) |
- |
100 |
|
- |
| Cl.11.1 of Cl.11(Electric Shock Hazard) |
- |
100 |
|
- |
| Cl.11.1 a) of Cl.11(Electric Shock Hazard) |
- |
100 |
|
- |
| Cl.11.1 b) of Cl.11(Electric Shock Hazard) |
- |
100 |
|
- |
| Cl.11.2 of Cl.11(Heating) |
- |
100 |
|
- |
| Cl.11.2.1 of Cl.11.2(Requirements) |
- |
100 |
|
- |
| Cl.11.2.1 i) of Cl.11.2(No danger of fire to the surroundings) |
- |
100 |
|
- |
| Cl.11.2.1 ii) of Cl.11.2(Safety not impaired by abnormal heat) |
- |
100 |
|
- |
| Cl.11.2.1 of Cl.11.2(Flames extinguish within 10 seconds) |
- |
100 |
|
- |
| Cl.11.2.1 of Cl.11.2(No hazard from softening solder) |
- |
100 |
|
- |
| Cl.11.2.2 of Cl.11.2(Measurement of temperature rises) |
- |
100 |
|
- |
| Cl.11.2.3 of Cl.11.2(Accessible parts) |
- |
100 |
|
- |
| Cl.11.2.4 of Cl.11.2(Parts, other than windings and printed boards, providing electrical insulation) |
- |
100 |
|
- |
| Cl.11.2.5 of Cl.11.2(Parts acting as a support or a mechanical barrier) |
- |
100 |
|
- |
| Cl.11.2.6 of Cl.11.2(Windings ) |
- |
100 |
|
- |
| Cl.11.2.7 of Cl.11.2(Printed boards) |
- |
100 |
|
- |
| Cl.11.2.7 i) of Cl.11.2(Printed boards) |
- |
100 |
|
- |
| Cl.11.2.7 i) a) of Cl.11.2(Printed boards) |
- |
100 |
|
- |
| Cl.11.2.7 i) b) of Cl.11.2(Printed boards) |
- |
100 |
|
- |
| Cl.11.2.7 ii) of Cl.11.2(Printed boards) |
- |
100 |
|
- |
| Cl.11.2.7 iii) of Cl.11.2(Printed boards) |
- |
100 |
|
- |
| Cl.11.2.8 of Cl.11.2(Parts not subject to a limit under7.1.1 to 7.1.4) |
- |
100 |
|
- |
| Cl.12.1.1 of Cl.12.1(Requirements) |
- |
100 |
|
- |
| Cl.12.1.2 of Cl.12.1(Bump test ) |
- |
100 |
|
- |
| Cl.12.1.3 of Cl.12.1(Vibration test) |
- |
100 |
|
- |
| Cl.12.1.4 of Cl.12.1(Impact test) |
- |
100 |
|
- |
| Cl.12.1.4 i) of Cl.12.1(Impact test) |
- |
100 |
|
- |
| Cl.12.1.4 ii) of Cl.12.1(Impact test) |
- |
100 |
|
- |
| Cl.12.1.5 of Cl.12.1(Drop test) |
- |
100 |
|
- |
| Cl.12.1.6 of Cl.12.1(Stress relief test) |
- |
100 |
|
- |
| Cl.12.2 of Cl.12(Fixing of actuating elements) |
- |
100 |
|
- |
| Cl.12.3 of Cl.12(Remote control devices held in hand) |
- |
100 |
|
- |
| Cl.12.4 of Cl.12(Drawers ) |
- |
100 |
|
- |
| Cl.12.5 of Cl.12(Antenna coaxial sockets mounted on the apparatus) |
- |
100 |
|
- |
| Cl.12.6 of Cl.12(Telescoping or rod antennas) |
- |
100 |
|
- |
| Cl.12.6.1 of Cl.12.6(General requirements) |
- |
100 |
|
- |
| Cl.12.6.1 i) of Cl.12.6(General requirements) |
- |
100 |
|
- |
| Cl.12.6.2 of Cl.12.6(Physical securement) |
- |
100 |
|
- |
| Cl.12.7 of Cl.12(Apparatus containing coin / button cell batteries) |
- |
100 |
|
- |
| Cl.12.7.3 of Cl.12.7(Tests) |
- |
100 |
|
- |
| Cl.12.7.3.2 of Cl.12.7.3(Stress relief test) |
- |
100 |
|
- |
| Cl.12.7.3.3 of Cl.12.7.3(Battery replacement test) |
- |
100 |
|
- |
| Cl.12.7.3.4 of Cl.12.7.3(Drop test) |
- |
100 |
|
- |
| Cl.12.7.3.5 of Cl.12.7.3(Impact test) |
- |
100 |
|
- |
| Cl.12.7.3.6 of Cl.12.7.3(Crush test) |
- |
100 |
|
- |
| Cl.12.7.4 of Cl.12.7(Compliance) |
- |
100 |
|
- |
| Cl.13.1 of Cl.13(General) |
- |
100 |
|
- |
| Cl.13.2 of Cl.13(Determination of Working voltage) |
- |
100 |
|
- |
| Cl.13.3 of Cl.13(Clearances) |
- |
100 |
|
- |
| Cl.13.3.1 of Cl.13.3(General) |
- |
100 |
|
- |
| Cl.13.3.2 of Cl.13.3(Clearances in circuits conductively connected to the mains) |
- |
100 |
|
- |
| Cl.13.3.3 of Cl.13.3(Clearances in circuits not conductively connected to the mains) |
- |
100 |
|
- |
| Cl.13.3.4 of Cl.13(Measurement of transient voltages) |
- |
100 |
|
- |
| Cl.13.4 a) of Cl.13(Creepage distances ) |
- |
100 |
|
- |
| Cl.13.4 b) of Cl.13(Creepage distances ) |
- |
100 |
|
- |
| Cl.13.4 c) of Cl.13(Creepage distances ) |
- |
100 |
|
- |
| Cl.13.6 a) of Cl.13(Jointed insulation ) |
- |
100 |
|
- |
| Cl.13.6 b) of Cl.13(Jointed insulation ) |
- |
100 |
|
- |
| Cl.13.6 c) of Cl.13(Jointed insulation ) |
- |
100 |
|
- |
| Cl.13.6 d) of Cl.13(Jointed insulation ) |
- |
100 |
|
- |
| Cl.13.7 of Cl.13(Enclosed and sealed parts) |
- |
100 |
|
- |
| Cl.13.8 of Cl.13(Parts filled with insulating compound, meeting the requirements of 8.8) |
- |
100 |
|
- |
| Cl.15.1.2 of Cl.15.1(Design of connectors other than for mains power *) |
- |
100 |
|
- |
| Cl.15.2 of Cl.15(Provisions for protective earthing) |
- |
100 |
|
- |
| Cl.15.3 of Cl.15(Terminals for external flexible cords and for permanent connection to the mains supply*) |
- |
100 |
|
- |
| Cl.15.3.1 of Cl.15.3(Adequate terminals for connection of permanent wiring*) |
- |
100 |
|
- |
| Cl.15.3.2 of Cl.15.3(Reliable connection of non-detachable cords) |
- |
100 |
|
- |
| Cl.15.3.2 i) of Cl.15.3(Not soldered to conductors of a printed circuit board) |
- |
100 |
|
- |
| Cl.15.3.2 ii) of Cl.15.3(Adequate clearances and creepage distances between connections should a wire break away) |
- |
100 |
|
- |
| Cl.15.3.3 of Cl.15.3(Screws and nuts clamping conductors have adequate threads: ISO 261, ISO 262 or similar*) |
- |
100 |
|
- |
| Cl.15.3.4 of Cl.15.3(Conductors adequately fixed (two independent fixings) *) |
- |
100 |
|
- |
| Cl.15.3.5 of Cl.15.3(Terminals allow connection of conductors having appropriate cross-sectional area) |
- |
100 |
|
- |
| Cl.15.3.6 of Cl.15.3(Terminals to 15.3.3 have sizes required by table 16) |
- |
100 |
|
- |
| Cl.15.3.7 of Cl.15.3(Terminals clamp conductors between metal and have adequate pressure) |
- |
100 |
|
- |
| Cl.15.3.7 i) of Cl.15.3(Terminals designed to avoid conductor slipping out when tightened) |
- |
100 |
|
- |
| Cl.15.3.7 ii) of Cl.15.3(Terminals adequately fixed when tightened or loosened (no loosening, wiring not stressed, distances not reduced)) |
- |
100 |
|
- |
| Cl.15.3.8 of Cl.15.3(Terminals carrying a current more than) |
- |
100 |
|
- |
| Cl.15.3.8 i) of Cl.15.3(0.2 A, contact pressure not transmitted by insulating material except ceramic*) |
- |
100 |
|
- |
| Cl.15.3.9 of Cl.15.3(Termination of non-detachable cords: wires terminated near to each other) |
- |
100 |
|
- |
| Cl.15.3.9 i) of Cl.15.3(Terminals located and shielded: test with 8 mm strand) |
- |
100 |
|
- |
| Cl.15.4 of Cl.15(Devices forming a part of the mains plug*) |
- |
100 |
|
- |
| Cl.15.4.1 of Cl.15.4(No undue strain on mains socket-outlets.) |
- |
100 |
|
- |
| Cl.15.4.1 i) of Cl.15.4(Device shall be tested on the equipment as per Fig.11: Torque to be applied : 0.25 Nm (Max)) |
- |
100 |
|
- |
| Cl.15.4.2 of Cl.15.4(Device complies with standard for dimensions of mains plugs) |
- |
100 |
|
- |
| Cl.15.4.3 of Cl.15.4(Device has adequate mechanical strength (tests a,b,c)) |
- |
100 |
|
- |
| Cl.16.2 of Cl.16(Mains cords conductors shall have a nominal cross-sectional area not less than the values given in Table 18, for rated current consumption of the apparatus) |
- |
100 |
|
- |
| Cl.16.3 a) of Cl.16(Flexiblecordsnotcomplyingwith16.1, used for interconnections between separate units of equipment used in combination and carrying hazardous live voltages, have adequate dielectric strength as perCl.10.3) |
- |
100 |
|
- |
| Cl.16.4 of Cl.16(Flexible cords used for connection between equipment have adequate cross-sectional areas to avoid temperature rise under normal and fault conditions) |
- |
100 |
|
- |
| Cl.16.5 a) of Cl.16(Adequate strain relief on external flexible cords) |
- |
100 |
|
- |
| Cl.16.5 b) of Cl.16(Not possible to push cord back into equipment) |
- |
100 |
|
- |
| Cl.16.5 c) of Cl.16(Strain relief device unlikely to damage flexible cord) |
- |
100 |
|
- |
| Cl.16.5 d) of Cl.16(For mains cords of Class I equipment, hazardous live conductors become taut before earth conductor) |
- |
100 |
|
- |
| Cl.16.6 of Cl.16(Apertures for external flexible cord: no risk of damage to the cord during assembly or movement in use) |
- |
100 |
|
- |
| Cl.16.7 a) of Cl.16(Transportable apparatus fitted with detachable cord sets with appliance inlet as perIEC60320-1 or) |
- |
100 |
|
- |
| Cl.16.7 b) of Cl.16(Transportable apparatus shall have a means of stowage to protect the cord) |
- |
100 |
|
- |
| 17.1 a) of Cl.17(Screws are loosened and then tightened with a torque according to table20) |
- |
100 |
|
- |
| Cl.17.1 b) of Cl.17(5 times in the case of screws operating in a thread of metal) |
- |
100 |
|
- |
| Cl.17.1 c) of Cl.17(10 times in the case of screws operating in wood or in a thread in insulating material:) |
- |
100 |
|
- |
| Cl.17.2 of Cl.17(Correct introduction of screws into female threads in non-metallic material) |
- |
100 |
|
- |
| Cl.17.3 a) of Cl.17(Screws or other fixing devices intended to fix Covers, legs, stands or the like, shall be captive in order to prevent replacement during servicing by screws or other fixing devices……) |
- |
100 |
|
- |
| Cl.17.3 b) of Cl.17(Non-captive fixing screws: no hazard when replaced by a screw whose length is 10 times its diameter) |
- |
100 |
|
- |
| Cl.17.4 of Cl.17(No loosening of conductive parts carrying a current > 0.2 A) |
- |
100 |
|
- |
| Cl.17.5 of Cl.17(Contact pressure not transmitted through plastic other than ceramic for connections carrying a current > 0.2 A*) |
- |
100 |
|
- |
| Cl.17.6 of Cl.17(Stranded conductors of flexible supply cords carrying a current > 0.2 A with screw terminals not consolidated by solder *) |
- |
100 |
|
- |
| Cl.17.7 of Cl.17(Cover fixing devices other than screws have adequate strength and their positioning is unambiguous) |
- |
100 |
|
- |
| Cl.17.8 of Cl.17(Detachable legs or stands supplied by the manufacturer of the apparatus shall be delivered with the relevant fixing means *) |
- |
100 |
|
- |
| Cl.17.9 a) of Cl.17(Internal pluggable connections, affecting safety, unlikely to become disconnected) |
- |
100 |
|
- |
| Cl.17.9 b) of Cl.17(By applying a 2N pull force in any direction to the connection, in case of doubt) |
- |
100 |
|
- |
| Cl.19.1 of Cl.19(Stability and mechanical hazards) |
- |
100 |
|
- |
| Cl.19.1 of Cl.19(Stability requirements) |
- |
100 |
|
- |
| Cl.19.2 of Cl.19(Test at 10° to the horizontal) |
- |
100 |
|
- |
| Cl.19.3 of Cl.19(Vertical force test ) |
- |
100 |
|
- |
| Cl.19.4 of Cl.19(Horizontal force test) |
- |
100 |
|
- |
| Cl.19.5 of Cl.19(Test of edges and corners) |
- |
100 |
|
- |
| Cl.19.7 of Cl.19(Wall or ceiling mounting means) |
- |
100 |
|
- |
| Cl.19.7.1 of Cl.19..7(Requirements) |
- |
100 |
|
- |
| Cl.19.7.3 of Cl.19.7(Compliance) |
- |
100 |
|
- |
| Cl.19.6.2 of Cl.19.6(Fragmentation test) |
- |
100 |
|
- |
| Cl.20.1 of Cl.20(Requirements) |
- |
100 |
|
- |
| Cl.19.6.1 of Cl.19.6(Requirements) |
- |
100 |
|
- |
| Cl.20.2.5 of Cl.20.2(Components and parts not covered by 20.2.2, 20.2.3 and 20.2.4) |
- |
100 |
|
- |
| Cl.20.2.5 i) of Cl.20.2(Components and parts not covered by 20.2.2, 20.2.3 and 20.2.4) |
- |
100 |
|
- |
| Cl.20.2.5 ii) of Cl.20.2(Components and parts not covered by 20.2.2, 20.2.3 and 20.2.4) |
- |
100 |
|
- |
| 20(Resistance to fire) |
- |
100 |
|
- |
| Cl.20.3 of Cl.20(Fire enclosure*) |
- |
100 |
|
- |
| Cl.20.3.1 of Cl.20.3(Fire enclosure*) |
- |
100 |
|
- |
| Cl.20.3.2 of Cl.20.3(Fire enclosure*) |
- |
100 |
|
- |
| Cl.20.3.3 of Cl.20.3(Fire enclosure*) |
- |
100 |
|
- |
| Annex-A(Additional requirements for apparatus with protection against splashing water) |
- |
100 |
|
- |
| 3(General requirements) |
- |
100 |
|
- |
| Annex-B(Apparatus to be connected to the TELECOMMUNICATION NETWORKS) |
- |
100 |
|
- |
| Cl.5.5.2 a) of Cl.5.5(Mains powered equipment not exposed to dripping or splashing. Warning concerning objects filled with liquid, etc.) |
- |
100 |
|
- |
| Cl.8.5 ii) of Cl.8(Resistors bridging basic insulation shall complying with 14.1 a) *) |
- |
100 |
|
- |
| Cl.8.11 i) of Cl.8(Noun due reduction of creepage or clearance distances if wires become detached) |
- |
100 |
|
- |
| Cl.8.11 ii) of Cl.8(Vibration test carried out) |
- |
100 |
|
- |
| Cl.9.1 of Cl.9(Testing on the outside) |
- |
100 |
|
- |
| Cl.12.5 a) of Cl.12(Endurance test,) |
- |
100 |
|
- |
| Cl.12.5 b) of Cl.12(Impact test,) |
- |
100 |
|
- |
| Cl.12.5 c) of Cl.12(Torque test) |
- |
100 |
|
- |
| Cl.8.7 v) of Cl.8(Double or reinforced insulation being bridged with a single capacitor or RC-unit complying with 14.3.2 b)) |
- |
100 |
|
- |
| Cl.8.10 of Cl.8(Double insulation between conductors connected to accessible parts and parts connected to the mains) |
- |
100 |
|
- |
| Cl.12.7.1 of Cl.12.7(Coin/button cell batteries with a diameter of 32 mm or less.) |
- |
100 |
|
- |
| Cl.12.7.2 of Cl.12.7(Construction requirementss) |
- |
100 |
|
- |
| Cl.15.1.1 i) of Cl.15.1(Plugs and Sockets*) |
- |
100 |
|
- |
| Cl.15.2 i) of Cl.15(Provisions for protective earthing) |
- |
100 |
|
- |
| Cl.15.2 ii) of Cl.15(Provisions for protective earthing) |
- |
100 |
|
- |
| Cl.15.2 iii) of Cl.15(Provisions for protective earthing) |
- |
100 |
|
- |
| Cl.15.2 iv) of Cl.15(Provisions for protective earthing) |
- |
100 |
|
- |
| Cl.15.2 v) of Cl.15(Provisions for protective earthing) |
- |
100 |
|
- |
| Cl.15.3.2 iii) of Cl.15.3(Wire secured by additional means to the conductor) |
- |
100 |
|
- |
| Cl.16.1 a) of Cl.16(Mains supply flexible cords shall be sheathed type, complying with IEC 60227 for PVC cords or as per IEC 60245 for synthetic rubber cords) |
- |
100 |
|
- |
| Cl.16.1 b) of Cl.16(Non-detachable cords for Class I have green/yellow core for protective earth) |
- |
100 |
|
- |
| Cl.19.1 i) of Cl.19(Stability requirements) |
- |
100 |
|
- |
| Cl.19.6 of Cl.19(Mechanical strength of glass) |
- |
100 |
|
- |
| Cl.8.7 iv) of Cl.8(Double or reinforced insulation being bridged with 2 capacitors or RC-units in series complying with 14.3.2 a)) |
- |
100 |
|
- |
| 16.3b(Cord Bending Test) |
- |
100 |
|
- |
| Cl.15.1.2 i) of Cl.15.1(Design of sockets with symbol of 5.3 b) design *) |
- |
100 |
|
- |
| Cl.11.2.1 of Cl.11.2(Soldered terminations not used as protective mechanism) |
- |
100 |
|
- |
|
29 Apr, 2027 |
- Exclusion: Cl.6 (Hazardous radiations), Cl. 6.2 (Laser Radiation), Cl. 6.1 (Ionizing radiation), Cl. 6.3 (Light Emitting diode(LEDs)), Cl. 14 (Components), Cl.20.2.2 of Cl.20.2 (Electrical components ), CL. 18 (Mechanical strength of picture tubes and protection against the effects of implosion), Cl.20.2.1 a) of Cl.20.2 (Exemption for components contained in an enclosure of material V-0 to IEC60695- 11-10 with openings not exceeding 1 mm in width), Cl.20.2.1 b) of Cl.20.2 (Exemption for small components), Cl.20.2.4 of Cl.20.2 (Printed boards), Cl.20.2 of Cl.20 (Electrical components and mechanical parts), Cl.20.3 of Cl.20 (Fire enclosure*), 8.16/ H 2.2/ H 2.3 (Requirements for insulated winding wires for use without additional interleaved insulation), Cl. 8.16 (Wound Component), Cl. 15 (Internal wires and power cords), Cl. 20.2.4 (Printed Boards), Cl.20.2.5 ii) of Cl.20.2 (Components and parts not covered by 20.2.2, 20.2.3 and 20.2.4), Cl.20.2.4 i) of Cl.20.2 (Printed boards), Cl.8.7 of Cl.8 (Components bridging insulation), Cl.8.7 ii) of Cl.8 (Components bridging basic, supplementary, double or reinforced insulation complying with 14.2 a) or 14.4), Cl.8.7 i) of Cl.8 (Basic insulation bridged by components complying with 14.4.5.3), Cl.8.7 iii) of Cl.8 (Basic and supplementary insulation each being bridged by a capacitor or RC-unit complying with 14.3.2 a)), Cl.8.16 of Cl.8 (Insulated winding wire without additional interleaved insulation), Cl.8.20 of Cl.8 (Bridging components comply with clause 14), Cl. Cl.15.1 of Cl.15 (Plugs and Sockets*), Cl.15.1.3 of Cl.15.1 (Design of terminals and connectors used in output circuits of supply apparatus*), Cl.20.2 of Cl.20 (Electrical components and mechanical parts), Cl.20.2.2 of Cl.20.2 (Electrical components ), Cl.20.2.3 of Cl.20.2 (Internal wiring), Cl.20.2.4 of Cl.20.2 (Printed boards), Cl.20.2.1 b) of Cl.20.2 (Exemption for small components), Cl.8.5 iii) of Cl.8 (Capacitors bridging basic insulation shall complying with 14.2.1 a) *), Annex-L (Additional requirements for electronic flash apparatus for photographic purposes) |
| 10457 |
ABSOLUTE TESTING SERVICES, FARIDABAD
| 8174526
| IS 16046 : Part 1 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 1 Nickel Systems ( Second Revision ) |
- |
60000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
4500 |
|
- |
| 5(General Safety Considerations) |
- |
4500 |
|
- |
| 5.1(General) |
- |
4500 |
|
- |
| 5.2(Insulation and Wiring) |
- |
4500 |
|
- |
| 5.3(Venting) |
- |
4500 |
|
- |
| 5.5(Terminal Contacts) |
- |
4500 |
|
- |
| 5.6(Assembly of Cells into batteries) |
- |
4500 |
|
- |
| 5.7(Quality Plan) |
- |
4500 |
|
- |
| 6(Tyoe Test amd Sample Size) |
- |
4500 |
|
- |
| 7(Specific requirements and tests) |
- |
4500 |
|
- |
| 7.1(Charging procedure for test purposes) |
- |
4500 |
|
- |
| 7.2(Intended Use) |
- |
3500 |
|
- |
| 7.3(Reasonably foreseeable misuse) |
- |
3500 |
|
- |
| 8(Information for safety) |
- |
3500 |
|
- |
| 8.1(General) |
- |
3500 |
|
- |
| 8.2(Small Cell and battery safety information) |
- |
3500 |
|
- |
| 9(Marking) |
- |
2000 |
|
- |
| 9.1(Cell Marking) |
- |
2000 |
|
- |
| 9.2(Battery Marking) |
- |
2000 |
|
- |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
3500 |
|
- |
| 9.4(Other information) |
- |
2800 |
|
- |
| 10(Packaging) |
- |
3500 |
|
- |
| 5.4(Temperature, Voltage and Current Management) |
- |
4000 |
|
- |
|
13 Nov, 2026 |
- - |
| 10458 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 16103 : Part 1 (2012) |
Led modules for general lighting: Part 1 safety requirements |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
1000 |
|
- |
| 8(Terminals) |
- |
1000 |
|
- |
| 9(PROVISION FOR EARTHING) |
- |
1000 |
|
- |
| 10(Protection against accidental contact with live parts) |
- |
1000 |
|
- |
| 11(Mositure Resistance and Insulation) |
- |
3000 |
|
- |
| 12(Electric Strength) |
- |
1000 |
|
- |
| 13(Fault conditions) |
- |
1000 |
|
- |
| 15(Construction) |
- |
3000 |
|
- |
| 16(Creepage distance and clearances) |
- |
1000 |
|
- |
| 17(Screws, current carrying parts and connections) |
- |
3000 |
|
- |
| 18(Resistance to heat, fire and tracking) |
- |
6000 |
|
- |
| 19(Resistance to corrosion) |
- |
2000 |
|
- |
| 21(Heat management) |
- |
1000 |
|
- |
|
29 Apr, 2027 |
- - |
| 10459 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
1000 |
|
- |
| 8(Protection against accidental contact with live parts) |
- |
1000 |
|
- |
| 9(Terminals) |
- |
1000 |
|
- |
| 10(PROVISION FOR EARTHING) |
- |
1000 |
|
- |
| 11(MOISTURE RESISTANCE) |
- |
5000 |
|
- |
| 12(Electric Strength) |
- |
1000 |
|
- |
| 14(Fault conditions) |
- |
1000 |
|
- |
| 15(Transformer heating) |
- |
3000 |
|
- |
| 16(Construction) |
- |
3000 |
|
- |
| 17(Creepage distance and clearances) |
- |
2000 |
|
- |
| 18(Screws, current carrying parts and connections) |
- |
2000 |
|
- |
| 19(Resistance to heat, fire and tracking) |
- |
6000 |
|
- |
| 20(Resistance to corrosion) |
- |
3000 |
|
- |
| 13(Thermal endurance test for winding of ballasts) |
- |
0 |
|
- |
| 4(GENERAL REQUIREMENTS) |
- |
0 |
|
- |
| 5(GENERAL NOTES ON TESTS) |
- |
0 |
|
- |
| 6(CLASSIFICATION) |
- |
0 |
|
- |
| 7(Marking) |
- |
0 |
|
- |
| 8("PROTECTION AGAINST ACCIDENTAL
CONTACT WITH LIVE PARTS") |
- |
0 |
|
- |
| 9(TERMINALS) |
- |
0 |
|
- |
| 10(PROVISIONS FOR PROTECTIVE EARTHING) |
- |
0 |
|
- |
| 11(MOISTURE RESISTANCE AND INSULATION) |
- |
0 |
|
- |
| 12(ELECTRIC STRENGTH) |
- |
0 |
|
- |
| 14(FAULT CONDITIONS) |
- |
0 |
|
- |
| 15(TRANSFORMER HEATING) |
- |
0 |
|
- |
| 16(CONSTRUCTION) |
- |
0 |
|
- |
| 17(CREEPAGE DISTANCES AND CLEARANCES) |
- |
0 |
|
- |
| 18("SCREWS, CURRENT-CARRYING PARTS
AND CONNECTIONS") |
- |
0 |
|
- |
| 19(RESISTANCE TO HEAT, FIRE AND TRACKING) |
- |
0 |
|
- |
| 20(RESISTANCE TO CORROSION) |
- |
0 |
|
- |
|
29 Apr, 2027 |
- Exclusion: Cl.16 (Connector, MOV/VDR, Enclosures, Bridging resistor in primary circuit, (Inductor, Capacitor and RC units, Internal wire, SMPS/Mains Transformer, PCB material, Insulated tape, LED, Opto-coupler, Opto-coupler, EMI/EMC filter, Winding wire, Thin sheet materials, Heat shrinkage sleeve, Fuse, PCB material, RF suppression (X-Y capacitors), Cl. 19 (Metal base PCB for LED, Transparent cover, Bobbin, Terminals) |
| 10460 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
1000 |
|
- |
| 6(Interchangeability) |
- |
1000 |
|
- |
| 7(Protection against accidental contact with live parts) |
- |
3000 |
|
- |
| 8(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
| 9(MECHANICAL STRENGTH) |
- |
3000 |
|
- |
| 10(cap temperature) |
- |
2500 |
|
- |
| 11(Resistance to Heat) |
- |
4000 |
|
- |
| 12(Resistance to Flame and Ignition) |
- |
2000 |
|
- |
| 13(Fault conditions) |
- |
1000 |
|
- |
| 14(Creepage distances and clearances) |
- |
1000 |
|
- |
| 14(Creepage distance and clearances) |
- |
0 |
|
- |
| 4(General requirement and General test requirements) |
- |
0 |
|
- |
| 5(Marking) |
- |
0 |
|
- |
| 6(Interchangeability) |
- |
0 |
|
- |
| 7(Protection against accidental contact with live parts) |
- |
0 |
|
- |
| 8(Strength after humidity treatment) |
- |
0 |
|
- |
| 9(Mechanical strength) |
- |
0 |
|
- |
| 10(Cap temperature rise) |
- |
0 |
|
- |
| 11(Resistance to heat) |
- |
0 |
|
- |
| 12(Resistance to flame and ignition) |
- |
0 |
|
- |
| 13(Fault conditions) |
- |
0 |
|
- |
| 4(GENERAL REQUIREMENT AND GENERAL TEST REQUIREMENTS) |
- |
0 |
|
- |
| 15(Selection of lamps for tests (Sampling)) |
- |
500 |
|
- |
| 16(Condition of compliance) |
- |
500 |
|
- |
| 17(Tests) |
- |
500 |
|
- |
| Annex A(Ovreview of systems composed of LED modules and control gear) |
- |
500 |
|
- |
| Annex B(Lamps with operating position limitations) |
- |
500 |
|
- |
|
29 Apr, 2027 |
- - |
| 10461 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 10322 : Part 5 : Sec 9 (2017) |
Luminaires: Part 5 particular requirements: Sec 9 rope lights |
- |
33000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 21.6(Marking) |
- |
1000 |
|
- |
| 21.7(Construction) |
- |
3000 |
|
- |
| 21.8(Creepage Distance and Clearances) |
- |
2000 |
|
- |
| 21.9(Provision for earthing) |
- |
1000 |
|
- |
| 21.10(Terminals) |
- |
1000 |
|
- |
| 21.11(External & Internal Wiring) |
- |
1000 |
|
- |
| 21.12(Protection against electric shock) |
- |
1000 |
|
- |
| 21.13(Endurance Tests and Thermal Tests) |
- |
8000 |
|
- |
| 21.14(Resistance to Dust & Moisture) |
- |
5000 |
|
- |
| 21.15(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
| 21.16(Resistance to Heat , fire and tracking) |
- |
5000 |
|
- |
| 21.4(General Test Requireements) |
- |
100 |
|
- |
| 21.5(Classification of Luminaires') |
- |
100 |
|
- |
| 21.7.1(General) |
- |
200 |
|
- |
| 21.7.3(Terminals and supply connections) |
- |
200 |
|
- |
| 21.7.4(Control units) |
- |
200 |
|
- |
| 21.7.5(Mechanical strength) |
- |
200 |
|
- |
|
29 Apr, 2027 |
- - |
| 10462 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 10322 : Part 5 : Sec 8 (2013) |
Luminaires: Part 5 particular requirements: Sec 8 emergency lighting |
- |
33100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Classification of Luminaires') |
- |
1000 |
|
- |
| 6.0(Marking) |
- |
1000 |
|
- |
| 8.0(Creepage Distance and Clearances) |
- |
1000 |
|
- |
| 9.0(Provision for earthing) |
- |
1000 |
|
- |
| 10.0(Terminals) |
- |
1000 |
|
- |
| 11.0(External & Internal Wiring) |
- |
1000 |
|
- |
| 12.0(Protection against electric shock) |
- |
1000 |
|
- |
| 13.0(Endurance Tests and Thermal Tests) |
- |
6000 |
|
- |
| 14.0(Resistance to Dust & Moisture) |
- |
4000 |
|
- |
| 15.0(Insulation Resistance and Electric Strength) |
- |
2000 |
|
- |
| 16.0(Resistance to Heat , fire and tracking) |
- |
3000 |
|
- |
| 4(General Test Requireements) |
- |
500 |
|
- |
| 7.0(Construction) |
- |
1000 |
|
- |
| 20.0(BATTERY CHARGERS FOR SELFCONTAINED EMERGENCY LUMINAIRES) |
- |
500 |
|
- |
| 19.0(High Temperature Operation) |
- |
5000 |
|
- |
| 18.0(Changeover Operation) |
- |
1000 |
|
- |
| 22.0(REST MODE AND INIHIBITION MODE FACILITIES) |
- |
1000 |
|
- |
| 21.0(TEST DEVICES FOR EMERGENCY OPERATION) |
- |
100 |
|
- |
| 17.0(Functional Safety) |
- |
2000 |
|
- |
|
29 Apr, 2027 |
- - |
| 10463 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 10322 : Part 5 : Sec 7 (2017) |
Luminaires: Part 5 particular requirements: Sec 7 lighting chains (First Revision) |
- |
33000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 20.6(Marking) |
- |
1000 |
|
- |
| 20.7(Construction) |
- |
3000 |
|
- |
| 20.8(Creepage Distance and Clearances) |
- |
2000 |
|
- |
| 20.9(Provision for earthing) |
- |
1000 |
|
- |
| 20.10(Terminals) |
- |
1000 |
|
- |
| 20.11(External & Internal Wiring) |
- |
1000 |
|
- |
| 20.12(Protection against electric shock) |
- |
1000 |
|
- |
| 20.13(Endurance Tests and Thermal Tests) |
- |
8000 |
|
- |
| 20.14(Resistance to Dust & Moisture) |
- |
5000 |
|
- |
| 20.15(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
| 20.16(Resistance to Heat , fire and tracking) |
- |
6000 |
|
- |
| 20.4(General Test Requireements) |
- |
1000 |
|
- |
| 20.5(Classification of Luminaires') |
- |
1000 |
|
- |
|
29 Apr, 2027 |
- - |
| 10464 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 10322 : Part 5 : Sec 6 (2013) |
Luminaires: Part 5 particular requirements: Sec 6 handlamps |
- |
33000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Marking) |
- |
1000 |
|
- |
| 7.0(Construction) |
- |
3000 |
|
- |
| 8.0(Creepage Distance and Clearances) |
- |
2000 |
|
- |
| 9.0(Provision for earthing) |
- |
1000 |
|
- |
| 10.0(Terminals) |
- |
1000 |
|
- |
| 12.0(Protection against electric shock) |
- |
1000 |
|
- |
| 13.0(Endurance Tests and Thermal Tests) |
- |
8000 |
|
- |
| 14.0(Resistance to Dust & Moisture) |
- |
5000 |
|
- |
| 15.0(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
| 16.0(Resistance to Heat , fire and tracking) |
- |
6000 |
|
- |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
| 11.0(External & Internal Wiring) |
- |
0 |
|
- |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 8.2(Packing -Each Package shall bear the following Particulars) |
- |
0 |
|
- |
|
29 Apr, 2027 |
- - |
| 10465 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 10322 : Part 5 : Sec 2 (2012) |
Luminaires: Part 5 particular requirements: Sec 2 recessed luminaires (First Revision) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Marking) |
- |
1000 |
|
- |
| 7(Construction) |
- |
3000 |
|
- |
| 8(Creepage Distance and Clearances) |
- |
2000 |
|
- |
| 9(Provision for earthing) |
- |
1000 |
|
- |
| 10(Terminals) |
- |
1000 |
|
- |
| 11(External & Internal Wiring) |
- |
1000 |
|
- |
| 12(Protection against electric shock) |
- |
1000 |
|
- |
| 13(Endurance Tests and Thermal Tests) |
- |
8000 |
|
- |
| 14(Resistance to Dust and Moisture) |
- |
5000 |
|
- |
| 15(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
| 16(Resistance to Heat , fire and tracking) |
- |
6000 |
|
- |
| 17(Photometric Test) |
- |
7000 |
|
- |
| 4(General Test Requireements) |
- |
1000 |
|
- |
| 5(Classification of Luminaires') |
- |
1000 |
|
- |
|
29 Apr, 2027 |
- - |
| 10466 |
AADCO TESTING & RESEARCH LABORATORY PVT LTD (F28), GHAZIABAD
| 8141606
| IS 16720 (2018) |
Pulverized Fuel Ash-Cement Bricks- Specification |
ALL |
6500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 and fig.1A &1B(Dimensions- Length (L) ) |
- |
500 |
|
- |
| 4.1 and fig.1A &1B(Dimensions- Width (B) ) |
- |
500 |
|
- |
| 4.1 and fig.1A &1B(Dimensions- Height (H)) |
- |
500 |
|
- |
| 4.1 & 4.3 and fig.1A &1B(Dimensions - Depth) |
- |
500 |
|
- |
| 4.1 and fig.1A &1B(Dimensions) |
- |
500 |
|
- |
| 8.1(GENERAL) |
- |
500 |
|
- |
| 8.3(Density
Annex C of IS 2185 (Part 1)) |
- |
500 |
|
- |
| 8.4 and Table 1(Compressive Strength - Average
IS 3495 (Part 1)) |
- |
500 |
|
- |
| 8.5(Drying Shrinkage
IS 4139) |
- |
500 |
|
- |
| 8.6(Water Absorption
IS 3495 (Part 2)) |
- |
500 |
|
- |
|
26 Jul, 2027 |
- - |
| 10467 |
AADCO TESTING & RESEARCH LABORATORY PVT LTD (F28), GHAZIABAD
| 8141606
| IS 12894 (2002) |
Pulverized fuel ash - Lime bricks - Specification |
all |
6500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(General Requirements) |
- |
500 |
|
- |
| 3.2(General Requirements) |
- |
500 |
|
- |
| 3.3(General Requirements) |
- |
500 |
|
- |
| 3.4(General Requirements) |
- |
500 |
|
- |
| 3.5(General Requirements) |
- |
500 |
|
- |
| 5.1(Dimensions) |
- |
500 |
|
- |
| 5.2(Tolerance) |
- |
500 |
|
- |
| 7.1, Table -1(Average Wet Compressive Strength) |
- |
2000 |
|
- |
| 7.2(Drying Shrinkage) |
- |
500 |
|
- |
| 7.3(Efflorescence Test) |
- |
500 |
|
- |
| 7.4(Water Absorption) |
- |
500 |
|
- |
| 3.1(General Requirements) |
- |
500 |
|
- |
| 3.2(General Requirements) |
- |
500 |
|
- |
| 3.3(General Requirements) |
- |
500 |
|
- |
| 3.4(General Requirements) |
- |
500 |
|
- |
| 3.5(General Requirements) |
- |
500 |
|
- |
| 5.1(Dimensions) |
- |
500 |
|
- |
| 5.2(Tolerance) |
- |
500 |
|
- |
| 7.1, Table -1(Average Wet Compressive Strength) |
- |
2000 |
|
- |
| 7.2(Drying Shrinkage) |
- |
500 |
|
- |
| 7.3(Efflorescence Test) |
- |
500 |
|
- |
| 7.4(Water Absorption) |
- |
500 |
|
- |
|
26 Jul, 2027 |
- - |
| 10468 |
AADCO TESTING & RESEARCH LABORATORY PVT LTD (F28), GHAZIABAD
| 8141606
| IS 2185 : Part 3 (1984) |
Concrete Masonry Units Part 3 Autoclaved Cellular Aerated Concrete Blocks |
ALL |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(SURFACE TEXTURE AND FINISH) |
- |
500 |
|
- |
| 8(Physical requirments) |
- |
1000 |
|
- |
| 8.2(Physical requirments-Dimensions-Length) |
- |
500 |
|
- |
| 8.2(Physical requirments-Dimensions-Height) |
- |
500 |
|
- |
| 8.2(Physical requirments-Dimensions-Width) |
- |
500 |
|
- |
| 8.3(Physical requirments- Block density) |
- |
3000 |
|
- |
| 8.4(Physical requirments- Compressive strength) |
- |
3000 |
|
- |
| 8.5(Thermal Conductivity) |
- |
8000 |
|
- |
| 8.6( Drying Shrinkage ) |
- |
3000 |
|
- |
| 7(SURFACE TEXTURE AND FINISH) |
- |
- |
|
- |
| 8(Physical requirments) |
- |
- |
|
- |
| 8.2(Physical requirments-Dimensions-Length) |
- |
- |
|
- |
| 8.2(Physical requirments-Dimensions-Height) |
- |
- |
|
- |
| 8.2(Physical requirments-Dimensions-Width) |
- |
- |
|
- |
| 8.3(Physical requirments- Block density) |
- |
- |
|
- |
| 8.4(Physical requirments- Compressive strength) |
- |
- |
|
- |
| 8.5(Thermal Conductivity) |
- |
- |
|
- |
| 8.6( Drying Shrinkage ) |
- |
- |
|
- |
|
26 Jul, 2027 |
- - |
| 10469 |
AADCO TESTING & RESEARCH LABORATORY PVT LTD (F28), GHAZIABAD
| 8141606
| IS 15658 (2021) |
Concrete Paving Blocks - Specification ( First Revision ) |
ALL GRADE |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 7.1.1
(General Quality) |
- |
500 |
|
- |
| Clauses 7.1.2 & 9.1.2
(Visual Inspection) |
- |
500 |
|
- |
| Clause 7.1.3
(Colour and Texture) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (i)
(Width, W) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (ii)
(Length, L) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iii)
(Thickness, Th) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iv)
(Aspect Ratio, L/Th) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Width) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Depth) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Thickness of wearing Layer) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Plan Area (Asp)) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (ix)(Deviation from squareness) |
- |
500 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) b)(Water absorption (Average of three test specimens)) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) a)( Indivdual Water absorption) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) b)(Compressive strength (Average of eight test specimens)) |
- |
2500 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) ii)(Wet Abrasion resistance (Average of three test specimens)) |
- |
2000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) ii)(Dry Abrasion resistance (Average of three test specimens)) |
- |
2000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) b)(Average Tensile splitting strength ) |
- |
3000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) b)(Average Flexural strength ) |
- |
4000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 10 cycles) |
- |
2500 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 25 cycles) |
- |
5000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 50 cycles) |
- |
10000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 10 cycles) |
- |
2500 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 25 cycles) |
- |
5000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 50 cycles) |
- |
10000 |
|
- |
| Clause 7.1.1
(General Quality) |
- |
500 |
|
- |
| Clauses 7.1.2 & 9.1.2
(Visual Inspection) |
- |
500 |
|
- |
| Clause 7.1.3
(Colour and Texture) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (i)
(Width, W) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (ii)
(Length, L) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iii)
(Thickness, Th) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iv)
(Aspect Ratio, L/Th) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Width) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Depth) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Thickness of wearing Layer) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Plan Area (Asp)) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (ix)(Deviation from squareness) |
- |
500 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) b)(Water absorption (Average of three test specimens)) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) a)( Indivdual Water absorption) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) b)(Compressive strength (Average of eight test specimens)) |
- |
2500 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) ii)(Wet Abrasion resistance (Average of three test specimens)) |
- |
2000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) ii)(Dry Abrasion resistance (Average of three test specimens)) |
- |
2000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) b)(Average Tensile splitting strength ) |
- |
3000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) b)(Average Flexural strength ) |
- |
4000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 10 cycles) |
- |
2500 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 25 cycles) |
- |
5000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 50 cycles) |
- |
10000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 10 cycles) |
- |
2500 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 25 cycles) |
- |
5000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 50 cycles) |
- |
10000 |
|
- |
|
26 Jul, 2027 |
- - |
| 10470 |
National Test House (NR) - NTH, Ghaziabad
| 8101304
| IS 14255 (1995) |
Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.1 a) i)(Tests on phase/street light conductor: tensile test - Test method IS10810:Part 2) |
- |
250 |
|
- |
| 10.1 a) ii)(Wrapping test - 10810: Part 3) |
- |
250 |
|
- |
| 10.1 a) iii)(Resistance test - IS10810: Part 5) |
- |
250 |
|
- |
| 10.1 b) i)(Test on messenger conductor: Breaking load - IS 10810: Part 2) |
- |
250 |
|
- |
| 10.1 b) ii)(Test on messenger conductor: Elongation test - Cl 11.3) |
- |
250 |
|
- |
| 10.1 b) iii)(Test on messenger conductor: Resistance test - IS 10810: Part 5) |
- |
250 |
|
- |
| 10.1 c) i)(Physical tests for XLPE Insulation:
Tensile strength - IS 10810: Part 7) |
- |
250 |
|
- |
| 10.1 c) i)(Physical tests for XLPE Insulation:
elongation at break - IS 10810: part 7) |
- |
250 |
|
- |
| 10.1 c) ii)(Ageing in air oven : Tensile strength variation - IS 10810:Part 11) |
- |
250 |
|
- |
| 10.1 c) ii)(Ageing in air oven : Elongation variation- IS 10810: Part 11) |
- |
250 |
|
- |
| 10.1 c) iii)(Hot set test: Elongation under load - IS 10810: Part 30) |
- |
250 |
|
- |
| 10.1 c) iii)(Hot set test: Permanent elongation (set) after cooling - IS 10810: Part 30) |
- |
250 |
|
- |
| 10.1 c) iv)(Shrinkage test : Crack Observed - 10810:Part 12) |
- |
250 |
|
- |
| 10.1 c) iv)(Shrinkage test : Shrinkage - 10810:Part 12) |
- |
250 |
|
- |
| 10.1 c) v)(Water ahsorption (Gravimetric) - IS 10810: Part 33 ) |
- |
250 |
|
- |
| 10.1 d) i)(Physical test for PE insulation:
Tensile strength - IS 10810: Part 7 ) |
- |
250 |
|
- |
| 10.1 d) i)(Physical test for PE insulation: elongation at break - IS 10810: Part 7) |
- |
250 |
|
- |
| 10.1 d) ii)(Melt flow index- IS 10810: Part 23) |
- |
250 |
|
- |
| 10.1 d) iv)(Vicat softening point -IS 10810: Part 22) |
- |
250 |
|
- |
| 10.1 d) v)(Environmental stress cracking -IS 10810:Part29) |
- |
250 |
|
- |
| 10.1 f)(Insulation resistance (Volume resistivity) test a) volume resistivity at 27°C - IS 10810: Part 43) |
- |
250 |
|
- |
| 10.1 f)(Insulation resistance (Volume resistivity) test b) volume resistivity at 70°C - IS 10810: Part 43) |
- |
250 |
|
- |
| 10.1 g)(High voltage test - IS10810:Part 45) |
- |
250 |
|
- |
| 6.4(size of street lighting conductor) |
- |
250 |
|
- |
| 6.5(Size of messenger conductor ) |
- |
250 |
|
- |
| 4.1(Phase/Street Lighting conductor) |
- |
250 |
|
- |
| 4.2(Messenger (Neutral Conductor or Otherwise)) |
- |
250 |
|
- |
| 6.2(No of strands) |
- |
250 |
|
- |
| 5.1(Insulation) |
- |
250 |
|
- |
| 6.1(Flexibility class) |
- |
250 |
|
- |
| 6.2(Compactness) |
- |
250 |
|
- |
| 6.2(Surface) |
- |
250 |
|
- |
| 6.3(Protective barrier) |
- |
250 |
|
- |
| 6.6(Direction of outer layer) |
- |
250 |
|
- |
| 7.2( Thickness of insulation) |
- |
250 |
|
- |
| 7.3(Tolerance on thickness of insulation ) |
- |
250 |
|
- |
| 7.5(Colour of the insulation ) |
- |
250 |
|
- |
| 9.1(Assembly (Laying up)) |
- |
250 |
|
- |
| 9.3(Direction of lay) |
- |
250 |
|
- |
| 11.4(Bending Test on the Completed Cable ( Optional) ) |
- |
250 |
|
- |
|
26 Oct, 2025 |
- - |