S.No. Lab Name Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
10741 BIS, Eastern Regional Laboratory (ERL) IS 398 : Part 2 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) Complete up to 100 sqmm - View breakup
-
- -
All tests are available up to and including 100 sq.mm. For Above 100 sq.mm. facility not available for Stress-Strain Test, Surface Condition, Ultimate B/L on stranded conductor.
10742 BIS, Eastern Regional Laboratory (ERL) IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) For all grades except for the tests mentioned in remarks - View breakup
-
- -
Mech - Facility not available for pull out test, total elongation at maximum force. Chem- Facility not available for Micro-alloying elements. Declarations regarding type of 'Killed' material, Micro-alloys/low-alloys, Nitrogen content or any other parameter as per Note under clause 4.2 to be provided.
10743 BIS, Eastern Regional Laboratory (ERL) IS 1554 : Part 1 (1988) Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) Complete for Cat 01(up to 400sq.mm)Except optional test - View breakup
Rs.16650/- for single core unarmoured cable, Rs.22500/- for two core, unarmoured cable, Rs.26700/- for two core armoured cable (Excluding addl. Type test for cables with improved fire performance.) For multi core cables, extra charges @ 35 % for each additional core shall be levied. Material testing charges as per relevant referred ISs Testing charges for Additional Type Tests for Improved Fire Performance Tests: Rs. 7100/- for category C1 Rs. 11700/- for category C2
- -
For Category-01 and upto 400 sq mm: all tests are available except additional tests. For cat. C1 and C2 : Except oxygen Index,Temperature index, Flame Retardance, Smoke Density, Halogen acid Gas Evolution
10744 BIS, Guwahati Branch Laboratory (GBL) IS 269 (2015) Ordinary portland cement - Specification (Sixth Revision) - - View breakup
-
- -
Partial T.F. available. (Transverse Strength T.F. not available)
10745 BIS, Western Regional Laboratory (WRL) IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) - - View breakup
-
- -
Test facility not available for Copper purity test and FR/FRLSH category cables
10746 BIS, Southern Regional Laboratory (SRL) IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) PVC Cables except FR & FRLSH Category - View breakup
-
- -
" 30 m Excluding Except FR & FRLSH test, Cu Purity test
10747 BIS, Guwahati Branch Laboratory (GBL) IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
Partial T.F. available. (Transverse Strength Test not available)
10748 BIS, Western Regional Laboratory (WRL) IS 1554 : Part 1 (1988) Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) - - View breakup
Rs.16650/- for single core unarmoured cable, Rs.22500/- for two core, unarmoured cable, Rs.26700/- for two core armoured cable (Excluding addl. Type test for cables with improved fire performance.) For multi core cables, extra charges @ 35 % for each additional core shall be levied. Material testing charges as per relevant referred ISs Testing charges for Additional Type Tests for Improved Fire Performance Tests: Rs. 7100/- for category C1 Rs. 11700/- for category C2
- -
Test facility not available for tests as per Cl. 15.1.1 of C1 and C2 category
10749 BIS, Guwahati Branch Laboratory (GBL) IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
-
- -
Partial test facility (Transverse Strength Test not available).
10750 BIS, Western Regional Laboratory (WRL) IS 13334 : Part 1 (2014) Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) - - View breakup
Rs.10430/-
- -
(1) As per Cl. 5.7 The pesticide residues, heavy metals, toxins (aflatoxins and other naturally occurring toxins) and contaminants, if any, in the product shall not exceed the limits as prescribed in the Food Safety and Standards (Contaminants, Toxins and Residues) Regulations, 2011.’
10751 BIS, Guwahati Branch Laboratory (GBL) IS 303 (1989) Plywood for General Purposes - BWR/MR Rs 4000/- /BWR Grade, Rs.4900/- for MR Grade View breakup
-
- -
-
10752 BIS, Bengaluru Branch Laboratory (BNBL) IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
Expect Transverse Strength
10753 BIS, Western Regional Laboratory (WRL) IS 2347 (2017) Domestic pressure cooker - Specification (Sixth Revision) - - View breakup
Rs. 14700/- excluding test on handles and chemical tests.
- -
The following test facilities are not available: (1) Material as per Clause 5.1, 5.2, 5.5, 5.6, 5.7, 5.8, 5.9, 5.10, 5.11 (2) Test for Hard Anodized Surface. (3) Test for spring-loaded mechanism (4) Test for handle and knob. (5) Electrical Pressure cooker
10754 BIS, Western Regional Laboratory (WRL) IS 2124 (2000) Sodium bicarbonate - Specification (Second Revision) - Rs 4660/- for Pure Grade View breakup
Rs 8210/- for Analytical Reagent Grade Rs 4360/- for Refined Grade
- -
-
10755 BIS, Western Regional Laboratory (WRL) IS 4984 (2016) Polyethylene pipes for water supply - Specification (Fifth Revision) - - View breakup
-
- -
The following test facilities are not available: (1)Internal Pressure creep rupture test (2)Tensile Strength for Butt-fusion (Clause 8.8) (3) Slow Crack Growth rate test (Clause 8.10) (4) Depth of strip (Clause 6.2.1) (5) Overall Migration (Clause 8.6) (6) Carbon Black content ( Clause 8.3) (7) For Size above 250 mm
10756 BIS, Guwahati Branch Laboratory (GBL) IS 2062 (2011) Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) - - View breakup
-
- -
Mech- Except Y groove crackability, Impact test, NDT, grain size
10757 BIS, Guwahati Branch Laboratory (GBL) IS 1659 (2004) Block boards - Specification (Fourth Revision) MR/BWP - View breakup
Rs 5900/- for BWR Grade, Rs.6800/- for MR grade
- -
-
10758 BIS Patna Branch Laboratory (PBL) IS 2062 (2011) Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) - - View breakup
-
- -
All test facilities are available as per the IS except- i. Y-Groove Test (Clause 13) ii. Bend Test for thickness above 25 mm (Clause 11) iii. Tests for microalloying elements and Cr, Mo, Ni, Cu Al and B (Clause 8.2) Note: Prepared test piece of size 55 mm x10 mm x10 mm is required for Impact Test (Clause 12) *- The exact sample type, size and quantity may be ascertained from the latest product manual issued by BIS.
10759 BIS Patna Branch Laboratory (PBL) IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) - - View breakup
-
- -
All test facilities are available as per the IS except- i. Bond/Pull Out Test (Clause 5.7) ii. Total Elongation at Maximum Force (Clause 8.1 and Table 3) iii. Tensile Test of Sizes > 16mm (Clause 8.1 and Table 3) iv. Tests for microalloying elements (Ti, Nb, B, V), Cr, Mo, Cu, Ni and Al (Clause 4.2)
10760 BIS Patna Branch Laboratory (PBL) IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
-
- -
All test facilities are available as per the IS except Transverse Strength Test (Clause 7 and Table-2) which is an optional test
10761 BIS Patna Branch Laboratory (PBL) IS 1659 (2004) Block boards - Specification (Fourth Revision) - - View breakup
-
- -
All test facilities are available as per the IS
10762 BIS Patna Branch Laboratory (PBL) IS 303 (1989) Plywood for General Purposes - - Rs 4000/- /BWR Grade, Rs.4900/- for MR Grade View breakup
-
- -
All test facilities are available as per the IS
10763 BIS Patna Branch Laboratory (PBL) IS 269 (2015) Ordinary portland cement - Specification (Sixth Revision) - - View breakup
-
- -
All test facilities are available as per the IS except Transverse Strength Test (Clause 7 and Table-3) which is an optional test
10764 BIS Patna Branch Laboratory (PBL) IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
All test facilities are available as per the IS except Transverse Strength Test (Clause 7 and Table 2) which is an optional test
10765 BIS Patna Branch Laboratory (PBL) IS 12818 (2010) Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) - - View breakup
-
- -
All test facilities available except Effect on Water (Clause 9.7)
10766 BIS, Eastern Regional Laboratory (ERL) IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
Mech-Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement required as per Table 1, Confirmation for testing Alkali Content required.
10767 BIS, Eastern Regional Laboratory (ERL) IS 4984 (2016) Polyethylene pipes for water supply - Specification (Fifth Revision) All varieties - View breakup
-
- -
Mech- Facility not available for- Hydraulic test, Slow Crack Growth Rate and Internal Pressure Creep Rupture test. Fused pipes required to be provided for T/S of butt fusion joints. Chem- Facility not available for Oxidation Induction time
10768 BIS, Eastern Regional Laboratory (ERL) IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
-
- -
Mech- Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement (as per Table 1) and declaration of fly ash content & Confirmation for testing Alkali Content required.
10769 BIS, Eastern Regional Laboratory (ERL) IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) Complete for Category 01- up to & including 400 sq mm - View breakup
-
- -
Chem- Facility available for Cu purity only,Gr to be declared. Elect- Cat -01, 02 (Facility not available for- Loss of mass above 1.2 mm, Tensile & Elongation above 2.0 mm thickness.) Cat- FR, FR-LSH-( Facility not available for- oxygen index, temp. index test, Smoke Density Tests). Chem- Facility available for Cu purity only,Grade/class to be declared
10770 BIS, Central Laboratory (CL) IS 13334 : Part 1 (2014) Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) - - View breakup
-
- -
500 gm x 3