10981 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 8783 : Part 4 : Sec 3 (1995) |
Winding wires for submersible motors - Specification: Part 4 specification for individual wires: Sec 3 polyester and polypropylene insulated winding wires (First Revision) |
- |
Rs.8700/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1 (The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
|
|
|
6.1 (The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
|
|
|
6.1 (a) Reference to this Indian Standard;) |
- |
|
|
|
6.1 (b) Manufacturer's name,brand name or trade-mark;) |
- |
|
|
|
6.1 (c) Size of conductor / maximum overall diameter,) |
- |
|
|
|
6.1 (d) Length of conductor on spool / reel /coil;) |
- |
|
|
|
6.1 (e) Number of lengths onspool / reel / coil (if more than one);) |
- |
|
|
|
6.1 (f) Country of Manufacturer) |
- |
|
|
|
6.1 (g) Year of Manufacture.) |
- |
|
|
|
6.2 (BIS Certification Mark) |
- |
|
|
|
4 (i) Material) |
- |
|
|
|
5 (ii) Diameter [mm] Seperate wire:) |
- |
|
|
|
5 (ii) Diameter [mm] Wire taken from cable:) |
- |
|
|
|
5 (iii) Annealing test [Percentage] on Seperate wire:) |
- |
|
|
|
5 (iii) Annealing test [Percentage] on Wire taken from cable:) |
- |
|
|
|
5 (d) Resistance test [Ohm/km corrected to 20°c) |
- |
|
|
|
4.1, table 1 & 2 (a) Thickness of Polyster (mm)) |
- |
|
|
|
4.1, table 1 & 3 (b) Thickness of Polypropylene (mm)) |
- |
|
|
|
4.1, table 1 & 4 (c) Total thickness of Insulation(mm)) |
- |
|
|
|
4.2 (Application of insulation) |
- |
|
|
|
4.3 (Colour of Insuation) |
- |
|
|
|
4.4 (Overall diameter (mm)) |
- |
|
|
|
4 (Before ageing Tensile strength [N/mm²]) |
- |
|
|
|
4 (Before ageing Elongation at break [Percentage]) |
- |
|
|
|
4 (After ageing Tensile strength [N/mm²]) |
- |
|
|
|
4 (Variation on tensile strangth [Percentage]) |
- |
|
|
|
4 (After ageing Elongation at break [Percentage]) |
- |
|
|
|
4 (Variation on elongation at break [Percentage]) |
- |
|
|
|
4 (Shrinkage test [Percentage]) |
- |
|
|
|
4 (After Shrinkage Cracks found.) |
- |
|
|
|
4.1 (Water absorption test [Gravimetric] [mg/cm²]) |
- |
|
|
|
4.5 (High Voltage test [Water Immersion test] 3 KV for 1 Minute) |
- |
|
|
|
5 (The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
|
|
|
6 (The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
|
|
|
6 (a) Reference to this Indian Standard;) |
- |
|
|
|
6 (b) Manufacturer's name,brand name or trade-mark;) |
- |
|
|
|
6 (c) Size of conductor / maximum overall diameter,) |
- |
|
|
|
6 (d) Length of conductor on spool / reel /coil;) |
- |
|
|
|
6 (e) Number of lengths onspool / reel / coil (if more than one);) |
- |
|
|
|
6 (f) Country of Manufacturer Marking) |
- |
|
|
|
6 (g) Year of Manufacture.) |
- |
|
|
|
6.2 (BIS Certification Mark) |
- |
|
|
|
|
- |
- The following test facilities for clauses are not available:
Cl 4.1 Thickness of Insulation (Separate measurement of Thickness of Polypropylene and Polyester) |
10982 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 1875 (1992) |
Carbon steel billets, blooms, slabs and bars for forgings - Specification (Fifth Revision) |
- |
Rs.5400/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 8 (Diameter, Ovality & Weight) |
- |
|
|
|
Cl 9 (UTM & HBW) |
- |
|
|
|
Cl 7 (Workmanship) |
- |
|
|
|
6.1, 6.2 (carbon) |
- |
|
|
|
6.1, 6.2 (sulphur) |
- |
|
|
|
6.1, 6.2 (silicon ) |
- |
|
|
|
6.1, 6.2 (manganese) |
- |
|
|
|
6.1, 6.2 (phosphorus) |
- |
|
|
|
|
- |
- Excluding Grain size, Microstructure,Microalloying Elements |
10983 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 8783 : Part 4 : Sec 1 (1995) |
Winding wires for submersible motors - Specification: Part 4 specification for indmdual wires: Sec 1 HR PVC insulated wires (First Revision) |
- |
9300/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.3.1 (Conductor) |
- |
|
|
|
Cl.4 (Material) |
- |
|
|
|
Cl.5.1.1 (Dimensions) |
- |
|
|
|
Cl. 6 (Annealing Test) |
- |
|
|
|
Cl 6 (Resistance Test) |
- |
|
|
|
Cl 4.1.2 (Visual examination) |
- |
|
|
|
Cl.3.2 (Dielectric Material ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Volume resistivity) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Volume resistivity) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Tensile strength ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Elongation) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Tensile Strength) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Variation) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Elongation at Break ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Variation) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Shrinkage test ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Shrinkage test ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Water absorption (Gravimetric) ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Hot deformation Test ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Heat shock Test ) |
- |
|
|
|
Cl.4.1 (Insulation ) |
- |
|
|
|
Cl.4.2 (Application) |
- |
|
|
|
Cl.4.3 (Colour) |
- |
|
|
|
Cl.4.4 (Overall Diameter) |
- |
|
|
|
Cl.4.5 (Finish) |
- |
|
|
|
Cl.4.6 (High Voltage Test Water Immersion ) |
- |
|
|
|
|
- |
- - |
10984 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 1825 (1983) |
Specification for aluminium alloy milk cans (Second Revision) |
- |
Rs 4800.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8 (a) Rated Capacity) |
- |
|
|
|
8 (b) Point of Capacity) |
- |
|
|
|
8 (c) Batch OR Code No.) |
- |
|
|
|
8 (d) BIS Mark) |
- |
|
|
|
8 (e) Manufacturer's Trade Mark ) |
- |
|
|
|
2 (Capacity) |
- |
|
|
|
4 Fig. 1 (Dimensions & Shape) |
- |
|
|
|
4 Fig. 1 (A) |
- |
|
|
|
4 Fig. 1 (B) |
- |
|
|
|
4 Fig. 1 (C ) |
- |
|
|
|
4 Fig. 1 (D) |
- |
|
|
|
4 Fig. 1 (E) |
- |
|
|
|
4 Fig. 1 (F) |
- |
|
|
|
4 Fig. 1 (G) |
- |
|
|
|
4 Fig. 1 (H) |
- |
|
|
|
4 Fig. 1 (BOTTOM BAND) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Drain Holes ) |
- |
|
|
|
4 Fig. 1 (HANDLE ) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (LID) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Hole Dia 8 ,2 holes) |
- |
|
|
|
4 Fig. 1 (Hole Dia 12, 3 holes) |
- |
|
|
|
5 (a)Transport cans shall consist of a body, bottom band) |
- |
|
|
|
5 (lid and handles.) |
- |
|
|
|
5 (b)Minimum Thickness(in mm)) |
- |
|
|
|
5 (i) Body and Neck) |
- |
|
|
|
5 (ii) Bottom) |
- |
|
|
|
5 (iii) Lid (Inner)) |
- |
|
|
|
5 (iv) Lid (Outer)) |
- |
|
|
|
5 (c) Mode of Shaping) |
- |
|
|
|
5 (i) If the thickness at shoulder is less than 2.5 mm a ) |
- |
|
|
|
5 (reinforcement ring of 2 mm thickness shall be provided.) |
- |
|
|
|
5 (ii) Brinell Hardness 85 HB Min.) |
- |
|
|
|
5 (d) BOTTOM BAND- It shall be shrunk fit with a ) |
- |
|
|
|
5 (proper locking arrangement on the body. This shall) |
- |
|
|
|
5 (be followed by brazing or welding all round.) |
- |
|
|
|
5 (e) HANDLES (as per Cl 5.6)) |
- |
|
|
|
5 (f) SEALING LUG (as per Cl 5.7)) |
- |
|
|
|
5 (g)Workmanship and Finish- All brazing or welding shall ) |
- |
|
|
|
5 (be sound , free of porosity and shall be finished smooth .) |
- |
|
|
|
5 (h) Mass 6.5 Kg. Min.) |
- |
|
|
|
7 (i) Air Pressure Test (Cl 7.1)) |
- |
|
|
|
7 (ii) Drop Test (Cl 7.2)) |
- |
|
|
|
7 (iii) The cans when filled with water and inverted shall not show any profuse leakage through lids. ) |
- |
|
|
|
|
- |
- Test facility is complete, Facility for chemical testing is not available |
10985 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 15911 (2010) |
Structural steel (Ordinary Quality) - Specification |
All grades |
Rs 6750/- For elements other than Table-1: Rs 1004/- pe View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Table-1, 5.1, 8.1 & 8.2 (Carbon: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
Table-1, 5.1, 8.1 & 8.2 (Sulphur: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
Table-1, 5.1, 8.1 & 8.2 (Phosphorous: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
Table-1, 5.1, 8.1 & 8.2 (Manganese: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
Table-1, 5.1, 8.1 & 8.2 (Silicon: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
Table-1, 5.1, 8.1 & 8.2 (Copper: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
Table-1, 5.1, 8.1 & 8.2 (Nitrogen: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
5 and 10.3.1 (Tensile strength. IS 1608) |
- |
|
|
|
5 and 10.3.1 (Yield Stress. IS 1608) |
- |
|
|
|
5 and 10.3.1 (Percentage Elongation. . IS 1608) |
- |
|
|
|
11.3 ( Bend Test. IS 1599) |
- |
|
|
|
Cl 12 of IS 15911 and Table 2.1 of IS 808 (D) |
- |
|
|
|
Cl 12 of IS 15911 and Table 2.1 of IS 808 (B) |
- |
|
|
|
Cl 12 of IS 15911 and Table 2.1 of IS 808 (t) |
- |
|
|
|
Cl 12 of IS 15911 and Table 2.1 of IS 808 (R1) |
- |
|
|
|
Cl 12 of IS 15911 and Table 2.1 of IS 808 (R2) |
- |
|
|
|
Cl 12 of IS 15911 and Table 2.2 of IS 808 (Mass. IS 808) |
- |
|
|
|
7 (Freedom from defects) |
- |
|
|
|
Cl 12 of IS 15911 and Table 1 of IS 1732 (Clauses 3.1, 4.1,4.1.1 and Table 1 of IS 1732) |
- |
|
|
|
Cl 12 of IS 15911 and Table 2 of IS 1732 (Clauses 3.1, 4.1,4.1.1 and Table 1 of IS 1732) |
- |
|
|
|
Cl 12 of IS 15911 and Table 2 of IS 1863 (Clauses 5.1 and Table 2 of IS 1863) |
- |
|
|
|
Cl 12 of IS 15911 and Table 1 of IS 3954 (Clauses 4, 6.1 and Table 2 of IS 3954) |
- |
|
|
|
Cl 12 of IS 15911 and Table 1 of IS 1173 (Clauses 3.1 , 5.1 and Table 1 of IS 1173) |
- |
|
|
|
Cl 12 of IS 15911 and Table 1 of IS 1252 (Clauses 4.1 , 6.1 and Table 1 of IS 1252) |
- |
|
|
|
|
- |
- Chem- C, S, P, Mn, Si, Cu & N can only be carried out.Grade designation to be declared. |
10986 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 4224 (1972) |
Specification for steel wire for staples, pins and clips (First Revision) |
- |
525 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5 (Sizes and Tolerances - IS 4224) |
- |
|
|
|
7.1 (Tensile Test - IS 1608(Pt -1)) |
- |
|
|
|
4 (Freedom from defects , IS 4224) |
- |
|
|
|
7.2 (Reverse Bend Test--IS 1716) |
- |
|
|
|
|
- |
- Test facility is complete |
10987 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
Except C1 & C2 category. |
- View breakup
Rs.26250.00, extra charges @35% for each additional core shall be levied.optional test the charges shall be levied Rs.1200.00
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3 (CONDUCTOR: MATERIALS) |
- |
|
|
|
4 (INSULATION : MATERIALS) |
- |
|
|
|
5.1 (FILLER AND INNER SHEATH) |
- |
|
|
|
5.2 (FILLER AND INNER SHEATH) |
- |
|
|
|
6 (ARMOURING) |
- |
|
|
|
7 (OUTER SHEATH) |
- |
|
|
|
8.1 (CONDUCTOR: CONSTRUCTION) |
- |
|
|
|
8.2 (PROTECTIVE BARRIER) |
- |
|
|
|
8.3 (SIZE OF NEUTRAL CONDUCTOR) |
- |
|
|
|
9.1 (Insulation Applied by extrusicn) |
- |
|
|
|
9.2 (Thickness of Insulation - Average) |
- |
|
|
|
9.3 (Thickness of Insulation - Minimum) |
- |
|
|
|
9.4 (Application of Insulation) |
- |
|
|
|
10.1 (Core Identification) |
- |
|
|
|
10.2 (Core Identification- Neutral) |
- |
|
|
|
10.3 (Core Identification by number ) |
- |
|
|
|
10.4 (Core Identification by number - Neutral ) |
- |
|
|
|
11 (LAVING UP OF CORES) |
- |
|
|
|
12.1 & 12.2 (Inner sheath : Application) |
- |
|
|
|
12.3 (Thickness of Inner Sheath) |
- |
|
|
|
13.1 (Armouring: Application) |
- |
|
|
|
13.1.2 (Armouring: Coverage ) |
- |
|
|
|
13.1.3 (Armouring: Direction of Lay ) |
- |
|
|
|
13.2 (Type of armour ) |
- |
|
|
|
13.3 (Armouring : Dimensions -Wire Diameter) |
- |
|
|
|
13.4 (Armour: Joint) |
- |
|
|
|
13.5 (Armouring : Resistance Test) |
- |
|
|
|
13.6 a) (ARMOURING: Tensile Strength) |
- |
|
|
|
13.6 b) (ARMOURING: Elongation ) |
- |
|
|
|
13.6 c) (ARMOURING: Torsion Test (For round wire ) ) |
- |
|
|
|
13.6 d) (ARMOURING: Winding Test(For formed wire)) |
- |
|
|
|
13.6 e) (ARMOURING: Uniformity of zinc coating) |
- |
|
|
|
13.6 f) (ARMOURING: Mass of zinc coating ) |
- |
|
|
|
13.6 g) (ARMOURING: Resistivity) |
- |
|
|
|
14.1 (Outer Sheath : Application) |
- |
|
|
|
14.2 (Colour of outer sheath) |
- |
|
|
|
14.3 (Thickness of outer sheath - AVERAGE) |
- |
|
|
|
14.3 (Thickness of outer sheath - minimum) |
- |
|
|
|
15.1 a) i) (Annealing Test ( For copper wire ) ) |
- |
|
|
|
15.1 a) ii) (Tensile test (for aluminium) - Before stranding ) |
- |
|
|
|
15.1 a) ii) (Tensile test (for aluminium) - After stranding ) |
- |
|
|
|
15.1 a) iii) (Wrapping test (for aluminium)) |
- |
|
|
|
15.1 a) iv) (Resistance test - Main conductor) |
- |
|
|
|
15.1 a) iv) (Resistance test - Neutral conductor) |
- |
|
|
|
15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
|
|
|
15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
|
|
|
15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
|
|
|
15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
|
|
|
15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
|
|
|
15.1 d) iii) (Phyaical tests for insulation : Permanent set ) |
- |
|
|
|
15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
|
|
|
15.1 d) iv) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
|
|
|
15.1 d) v) (Insulation: Waterabsorption(gravimetric)) |
- |
|
|
|
15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
|
|
|
15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
|
|
|
15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
|
|
|
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
|
|
|
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
|
|
|
15.1 e) v) (Sheath : Hot deformation) |
- |
|
|
|
15.1 e) vi) (Sheath : Heat shock test) |
- |
|
|
|
15.1 e) vii) (Sheath : Thermalstability) |
- |
|
|
|
15.1 f) (INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
|
|
|
16.2 (HIGH VOLTAGE TEST ) |
- |
|
|
|
16.3 (FLAMMABILITY TEST : Period of Burning ) |
- |
|
|
|
16.3 (FLAMMABILITY TEST : Unaffected length ) |
- |
|
|
|
17.1 (Manufacturer'. identification) |
- |
|
|
|
17.2 (cable Indentification ) |
- |
|
|
|
17.3 (cable Code ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
|
|
|
|
- |
- Test facility not available for tests as per Clause 15.1.1 of C1 and C2 category |
10988 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 4250 (1980) |
Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) |
- |
- View breakup
Rs 9750/- Excluding Endurance test for juicers
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (Classification- IS 302-1 ) |
- |
|
|
|
6 (Classification- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.2 (Marking) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.4 (Marking) |
- |
|
|
|
7.5 (Marking) |
- |
|
|
|
7.6 (Marking) |
- |
|
|
|
8 ( Protection Against Electric Shock, IS 302-1) |
- |
|
|
|
9 (Starting, IS 302-1) |
- |
|
|
|
10 (Power Input and Current, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
13 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
|
|
|
13 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
|
|
|
15.1 (Moisture Resistance, IS 302-1) |
- |
|
|
|
15.2 (Moisture Resistance-Spillage test) |
- |
|
|
|
15 (Moisture Resistance, IS 302-1) |
- |
|
|
|
16 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
|
|
|
16 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
20 (Stability & Mechanical Hazards, IS 302-1) |
- |
|
|
|
20 (Stability & Mechanical Hazards, IS 302-1) |
- |
|
|
|
21 (Mechanical Strength, IS 302-1) |
- |
|
|
|
21 (Mechanical Strength, IS 302-1) |
- |
|
|
|
22.1 (Construction, IS 302-1) |
- |
|
|
|
22.2 (Construction) |
- |
|
|
|
22.3 (Construction) |
- |
|
|
|
22.4 (Construction) |
- |
|
|
|
22.5 (Construction) |
- |
|
|
|
22.6 (Construction) |
- |
|
|
|
22.8 (Construction) |
- |
|
|
|
22.9 (Construction) |
- |
|
|
|
22.1 (Construction) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.2 (Components) |
- |
|
|
|
24.4 (Components) |
- |
|
|
|
24.7 (Components) |
- |
|
|
|
24.8 (Components) |
- |
|
|
|
24.9 (Components) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
26 (Terminals for External Conductors, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
28 (Screws & Connections, IS 302-1) |
- |
|
|
|
29 (Clearances and Distances through Insulation, IS 302-1) |
- |
|
|
|
29 (Clearances and Distances through Insulation, IS 302-1) |
- |
|
|
|
30 (Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
|
|
|
30 (Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
|
|
|
31 (Resistance of Rusting, IS 302-1) |
- |
|
|
|
34.2 (Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
|
|
|
34.2 (Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
|
|
|
34.2 (Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
|
|
|
34.3 (Whisking egg whites ) |
- |
|
|
|
34.4 (IDLI batter-Grinding of black gram) |
- |
|
|
|
34.4 (IDLI batter-Grinding of rice) |
- |
|
|
|
34.4 (IDLI batter-Grinding of rice) |
- |
|
|
|
34.4 (IDLI batter-Grinding of rice) |
- |
|
|
|
34.5.1 (a) (Operational test for juicers ) |
- |
|
|
|
34.5.1 (b) (Operational test for juicers ) |
- |
|
|
|
34.5.2 (Operational test for juicers ) |
- |
|
|
|
35 (Temperature withstand test for bowl) |
- |
|
|
|
36 (Test for controls ) |
- |
|
|
|
37 (Strength of Assembly ) |
- |
|
|
|
37 (Strength of Assembly ) |
- |
|
|
|
|
- |
- The following test facilities are not available:
1. Cl.14 Transient Overvoltage test (as per IS 302-1)
2. Cl.19.11 and 19.12 Abnormal Operation test (as perIS 302-1) (for electronic circuit)
3. Cl 24 component test as per IS302-1 |
10989 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
16.13 (Test for Halogen Acid Gas Evolution) |
- |
|
|
|
3 (CONDUCTOR: MATERIALS) |
- |
|
|
|
4 (INSULATION : MATERIALS) |
- |
|
|
|
5.1 (FILLER AND INNER SHEATH) |
- |
|
|
|
5.2 (FILLER AND INNER SHEATH) |
- |
|
|
|
6 (ARMOURING) |
- |
|
|
|
7 (OUTER SHEATH) |
- |
|
|
|
8.1 (CONDUCTOR: CONSTRUCTION) |
- |
|
|
|
8.2 (PROTECTIVE BARRIER) |
- |
|
|
|
8.3 (SIZE OF NEUTRAL CONDUCTOR) |
- |
|
|
|
9.1 (Insulation Applied by extrusicn) |
- |
|
|
|
9.2 (Thickness of Insulation - Average) |
- |
|
|
|
9.3 (Thickness of Insulation - Minimum) |
- |
|
|
|
9.4 (Application of Insulation) |
- |
|
|
|
10.1 (Core Identification) |
- |
|
|
|
10.2 (Core Identification- Neutral) |
- |
|
|
|
10.3 (Core Identification by number ) |
- |
|
|
|
10.4 (Core Identification by number - Neutral ) |
- |
|
|
|
11 (LAVING UP OF CORES) |
- |
|
|
|
12.1 & 12.2 (Inner sheath : Application) |
- |
|
|
|
12.3 (Thickness of Inner Sheath) |
- |
|
|
|
13.1 (Armouring: Application) |
- |
|
|
|
13.1.2 (Armouring: Coverage ) |
- |
|
|
|
13.1.3 (Armouring: Direction of Lay ) |
- |
|
|
|
13.2 (Type of armour ) |
- |
|
|
|
13.3 (Armouring : Dimensions -Wire Diameter) |
- |
|
|
|
13.3 (Armouring : Dimensions -Formed wire ) |
- |
|
|
|
13.4 (Armour: Joint) |
- |
|
|
|
13.5 (Armouring : Resistance Test) |
- |
|
|
|
13.6 a) (ARMOURING: Tensile Strength) |
- |
|
|
|
13.6 b) (ARMOURING: Elongation ) |
- |
|
|
|
13.6 c) (ARMOURING: Torsion Test (For round wire ) ) |
- |
|
|
|
13.6 d) (ARMOURING: Winding Test(For formed wire)) |
- |
|
|
|
13.6 e) (ARMOURING: Uniformity of zinc coating) |
- |
|
|
|
13.6 f) (ARMOURING: Mass of zinc coating ) |
- |
|
|
|
13.6 g) (ARMOURING: Resistivity) |
- |
|
|
|
14.1 (Outer Sheath : Application) |
- |
|
|
|
14.2 (Colour of outer sheath) |
- |
|
|
|
14.3 (Thickness of outer sheath - AVERAGE) |
- |
|
|
|
14.3 (Thickness of outer sheath - minimum) |
- |
|
|
|
15.1 a) i) (Annealing Test ( For copper wire ) ) |
- |
|
|
|
15.1 a) ii) (Tensile test (for aluminium) - Before stranding ) |
- |
|
|
|
15.1 a) ii) (Tensile test (for aluminium) - After stranding ) |
- |
|
|
|
15.1 a) iii) (Wrapping test (for aluminium)) |
- |
|
|
|
15.1 a) iv) (Resistance test - Neutral conductor) |
- |
|
|
|
15.1 a) iv) (Resistance test - Main conductor) |
- |
|
|
|
15.1 a) iv) (Resistance test - Neutral conductor) |
- |
|
|
|
15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
|
|
|
15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
|
|
|
15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
|
|
|
15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
|
|
|
15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
|
|
|
15.1 d) iii) (Phyaical tests for insulation : Permanent set ) |
- |
|
|
|
15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
|
|
|
15.1 d) iv) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
|
|
|
15.1 d) v) (Insulation: Waterabsorption(gravimetric)) |
- |
|
|
|
15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
|
|
|
15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
|
|
|
15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
|
|
|
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
|
|
|
15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
|
|
|
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
|
|
|
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
|
|
|
15.1 e) v) (Sheath : Hot deformation) |
- |
|
|
|
15.1 e) vi) (Sheath : Heat shock test) |
- |
|
|
|
15.1 e) vii) (Sheath : Thermalstability) |
- |
|
|
|
15.1 f) (INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
|
|
|
16.2 (HIGH VOLTAGE TEST ) |
- |
|
|
|
16.3 (FLAMMABILITY TEST : Period of Burning ) |
- |
|
|
|
16.2 (HIGH VOLTAGE TEST ) |
- |
|
|
|
16.3 (FLAMMABILITY TEST : Period of Burning ) |
- |
|
|
|
16.3 (FLAMMABILITY TEST : Unaffected length ) |
- |
|
|
|
16.9 (Oxygen Index Test) |
- |
|
|
|
16.1 (Flame Retardance Test on Single Cables) |
- |
|
|
|
16.11 (Flame Retardance Test on Bunched Cables) |
- |
|
|
|
16.14 (Temperature Index) |
- |
|
|
|
17.1 (Manufacturer'. identification) |
- |
|
|
|
17.2 (cable Indentification ) |
- |
|
|
|
17.3 (cable Code ) |
- |
|
|
|
|
- |
- Test facility is complete |
10990 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 3975 (1999) |
Low carbon galvanized steel wires, formed wires and tapes for armouring of cables - Specification (Third Revision) |
- |
Rs 2700/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 6.1, Table-1 (Sulphur) |
- |
|
|
|
Clause 6.1, Table-1 (Phosphorus) |
- |
|
|
|
9.1 (Galvanizing Requirements ) |
- |
|
|
|
14 (a) (Marking) |
- |
|
|
|
14 (b) (Marking) |
- |
|
|
|
14 (c) (Marking) |
- |
|
|
|
14 (d) (Marking) |
- |
|
|
|
14 (e) (Marking) |
- |
|
|
|
14 (f) (Marking) |
- |
|
|
|
14 (g) (Marking) |
- |
|
|
|
14.2 (Marking) |
- |
|
|
|
7 (Dimensions) |
- |
|
|
|
7 (Dimensions) |
- |
|
|
|
7 (Dimensions) |
- |
|
|
|
7 (Dimensions) |
- |
|
|
|
7 (Dimensions) |
- |
|
|
|
11 (Freedom from defects) |
- |
|
|
|
9.1 (Galvanizing Requirements ) |
- |
|
|
|
9.2 (Galvanizing Requirements ) |
- |
|
|
|
9.3 (Galvanizing Requirements ) |
- |
|
|
|
8.1 (Mechanical Properties (as per table 5 of IS 1608)) |
- |
|
|
|
8.1 (Mechanical Properties (as per table 5 of IS 1608)) |
- |
|
|
|
8.2 (Mechanical Properties (as per IS 1717)) |
- |
|
|
|
8.3 (Mechanical Properties (as per IS 1755)) |
- |
|
|
|
8.4 (Mechanical Properties (as per IS 10810(Part- 42))) |
- |
|
|
|
14 (Marking) |
- |
|
|
|
14 (b) (Marking) |
- |
|
|
|
|
- |
- Test facility not available for the following:
1) Dimension radius R of formed wire. |
10991 |
BIS, Central Laboratory (CL)
| None
| IS 12176 (1987) |
Specification for sweetened ultra high temperature (UHT) treated condensed milk |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1.10.1 (Bacterial spores ( plate count )) |
- |
|
|
|
4.1.10.2 (Coliform count) |
- |
|
|
|
4.1.10.3 (Coagulase positive Staphylococcus aureus) |
- |
|
|
|
|
- |
- -Animal House;
Excluding -MEASUREMENT OF SIZE AND COUNT OF LACTOSE CRYSTALS, Cl. 4.1.10.1; |
10992 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 2465 (1984) |
Specification for cables for motor vehicles (Second Revision) |
Complete test facility for PVC Insulated General Wiring |
Single core PVC Insulated Unsheathed: Rs. 11030/- View breakup
Single core PVC Insulated Sheathed: 75 % additional for sheath. Multi core with PVC Sheath: 75% additional for each additional core. Round and flat tinned copper braids without further covering for earthing: Rs. 1115/- Above charges are excluding Material tests, Ageing in oxygen bomb, Capacitance test, Ozone resistance test, Effect of heat on flexibility, Effect of oils, Effect of lubricating oil, brake fluid, diesel and petrol, Effect of cooling on flexibility.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1 (Insulation) |
- |
|
|
|
7.3 (Insulation) |
- |
|
|
|
8 (Core Identification) |
- |
|
|
|
9 (Laying up of cores) |
- |
|
|
|
10.1.1 (Sheathing ) |
- |
|
|
|
10.2 (Sheathing ) |
- |
|
|
|
3 & 6 (Flexibility class) |
- |
|
|
|
3 & 6 (Construction) |
- |
|
|
|
3 & 6 (Diameter of wire(mm)) |
- |
|
|
|
3 & 6 (Annealing test) |
- |
|
|
|
3 & 6 (Persulphate Test) |
- |
|
|
|
3 & 6 (Conductor resistance Test (ohm/km at 20˚c)) |
- |
|
|
|
7.2, 10.3, 11 (Dimensions & thickness ) |
- |
|
|
|
7.2, 10.3, 11 (Dimensions & thickness ) |
- |
|
|
|
7.2, 10.3, 11 (Overall Dimension (mm)) |
- |
|
|
|
4.2 & 12.1 (Without Ageing For Insulation
Tensile Strength (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (f), 1 (elongation at break (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (f), 1 (Tensile Strength at break (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (e), 1 (elongation test at break) |
- |
|
|
|
4.2 & 12.1, (e), 1 (Tensile strength at break) |
- |
|
|
|
4.2 & 12.1, (f), 2 (Ageing in air oven) |
- |
|
|
|
4.2 & 12.1, (f), 3 (Ageing in oxygen bomb) |
- |
|
|
|
4.2 & 12.1, (e), 2 (After Ageing in air oven) |
- |
|
|
|
4.2 & 12.1, (e), 3 (Loss of mass test (mg/cm²) of Insulation) |
- |
|
|
|
4.2 & 12.1, (e), 3 (Loss of mass test (mg/cm²) of Sheath) |
- |
|
|
|
4.2 & 12.1, (e), 4 (Hot deformation test (%) of Insulation) |
- |
|
|
|
14 (High Voltage Test) |
- |
|
|
|
15 (SPARK TEST FOR SINGLE CORE GENERAL WIRING CABLES) |
- |
|
|
|
18.1 (EFFECT OF HEAT ON FLEXIBILITY FOR IGNITION CABLES) |
- |
|
|
|
19.2 (EFFECT OF OIL ON IGNITION CABLES) |
- |
|
|
|
20.3 (EFFECT OF LUBRICATING OIL) |
- |
|
|
|
20.3 (EFFECT OF LUBRICATING OIL) |
- |
|
|
|
20.3 (EFFECT OF BRAKE FLUID) |
- |
|
|
|
20.3 (EFFECT OF BRAKE FLUID) |
- |
|
|
|
20.3 (EFFECT OF DIESEL) |
- |
|
|
|
20.3 (EFFECT OF DIESEL) |
- |
|
|
|
20.3 (Wrapping test) |
- |
|
|
|
21.1 (EFFECT OF COOLING ON FLEXIBILITY) |
- |
|
|
|
21.2 (EFFECT OF COOLING ON FLEXIBILITY) |
- |
|
|
|
21.2 (EFFECT OF COOLING ON FLEXIBILITY) |
- |
|
|
|
22.1 (FLAMMABILITY TEST) |
- |
|
|
|
22.1 (FLAMMABILITY TEST) |
- |
|
|
|
23.1 (Manufacturer's Identification) |
- |
|
|
|
23.1 (Manufacturer's Identification) |
- |
|
|
|
24.1 (PACKING AND MARKING) |
- |
|
|
|
24.2 (PACKING AND MARKING) |
- |
|
|
|
24.2.1 (PACKING AND MARKING) |
- |
|
|
|
4.2 & 12.1, (e), 4 (Hot deformation test (%) of Sheath) |
- |
|
|
|
4.2 & 12.1, (e), 5 (Heat Shock Test of Insulation) |
- |
|
|
|
4.2 & 12.1, (e), 5 (Heat Shock Test of Sheath) |
- |
|
|
|
4.2 & 12.1, (e), 6 (Shrinkage Test (%) of Insulation) |
- |
|
|
|
4.2 & 12.1, (e), 6 (Shrinkage Test (%) of Sheath) |
- |
|
|
|
|
- |
- The following test facilities for ignition cables are not available:
Cl 16 Capacitance,
Cl 17 Ozone resistance,
Cl 18 Effect of heat on flexibility,
Cl 19 Effect of Oil test |
10993 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 1293 (2019) |
Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) |
UP TO 16A, 250V |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (RATINGS) |
- |
|
|
|
7.1.1 (Accessories Classification) |
- |
|
|
|
7.1.2 (Accessories Classification) |
- |
|
|
|
7.1.3 (Accessories Classification) |
- |
|
|
|
7.1.4 (Accessories Classification) |
- |
|
|
|
7.1.5 (Accessories Classification) |
- |
|
|
|
7.2.1 (Socket-Outlets Classification) |
- |
|
|
|
7.2.2 (Socket-Outlets Classification) |
- |
|
|
|
7.2.3 (Socket-Outlets Classification) |
- |
|
|
|
7.2.4 (Socket-Outlets Classification) |
- |
|
|
|
7.3 (Plug Classification) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
9 (CHECKING OF DIMENSIONS) |
- |
|
|
|
10 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
11 (Provision for earthing) |
- |
|
|
|
12 (terminals) |
- |
|
|
|
13.1 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.2 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.3 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.4 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.5 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.6 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.7 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.8 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.9 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.10 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.11 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.12 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.13 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.14 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.15 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.16 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.17 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.18 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.19 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.2 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.21 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.22 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.23 (Construction of fixed Socket Outlets) |
- |
|
|
|
14.1 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.2 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.3 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.4 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.5 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.6 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.7 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.8 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.9 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.10 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.11 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.12 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.13 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.14 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.15 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.16 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.17 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.18 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.19 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.20 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.21 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.22 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.23 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.24 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.25 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.26 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
15 (INTERLOCKED SOCKET-OUTLETS) |
- |
|
|
|
16.1 (Resistance to Ageing) |
- |
|
|
|
16.2 (RESISTANCE TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
|
|
|
16.3 (Resistance to Humidity) |
- |
|
|
|
17.1 (RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
17.2 (INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
17.3 (INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
18 (OPERATION OF EARTHING CONTACTS) |
- |
|
|
|
19 (TEMPERATURE RISE) |
- |
|
|
|
20 (Making & Breaking Capacity) |
- |
|
|
|
21 (Normal Operation) |
- |
|
|
|
22.1 (Verification of the Maximum Withdrawal Force) |
- |
|
|
|
22.2 (Verification of Minimum Withdrawal Force) |
- |
|
|
|
23.1 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
23.2 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
23.3 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
23.4 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
24.1 (MECHANICAL STRENGTH For all kinds of fixed socketoutlets) |
- |
|
|
|
24.1 (MECHANICAL STRENGTH For portable multiple and combined socket outlets with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
24.1 (MECHANICAL STRENGTH For surface mounting boxes) |
- |
|
|
|
24.2 (MECHANICAL STRENGTH For portable single socket-outlets: 1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
24.2 (MECHANICAL STRENGTH For portable multiple and combined socket outlets: 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.2 (MECHANICAL STRENGTH For plug 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.2 (MECHANICAL STRENGTH For plug 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.3 (MECHANICAL STRENGTH for fixed socket-outlets with a main part intended to be mounted directly on a surface) |
- |
|
|
|
24.4 (MECHANICAL STRENGTH For portable single socket-outlets: 1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
24.4 (MECHANICAL STRENGTH For portable multiple and combined socket outlets: 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.5 (MECHANICAL STRENGTH For portable single socket-outlets: 1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
24.5 (MECHANICAL STRENGTH For portable multiple and combined socket outlets: 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.5 (MECHANICAL STRENGTH For Plug 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.6 (MECHANICAL STRENGTH For screwed glands of accessories having an IP code higher than IP20) |
- |
|
|
|
24.7 (MECHANICAL STRENGTH For plug pins provided with insulating sleeves) |
- |
|
|
|
24.8 (MECHANICAL STRENGTH For shuttered socketoutlets) |
- |
|
|
|
24.9 (MECHANICAL STRENGTH For portable multiple and combined socket outlets (1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
24.9 (MECHANICAL STRENGTH For portable multiple and combined socket outlets (1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
24.10 (MECHANICAL STRENGTH For Plug (1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
24.10 (MECHANICAL STRENGTH For Plug (1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
24.11 (MECHANICAL STRENGTH For portable socketoutlets having means for suspension on a wall) |
- |
|
|
|
24.12 (MECHANICAL STRENGTH For portable socketoutlets having means for suspension on a wall) |
- |
|
|
|
24.13 (MECHANICAL STRENGTH For portable socketoutlets having means for suspension on a wall) |
- |
|
|
|
24.14.1 (MECHANICAL STRENGTH For fixed socket-outlets) |
- |
|
|
|
24.14.2 (MECHANICAL STRENGTH For fixed socket-outlets) |
- |
|
|
|
24.14.3 (MECHANICAL STRENGTH For plugs and portable socketoutlets) |
- |
|
|
|
24.15 (MECHANICAL STRENGTH) |
- |
|
|
|
24.16 (MECHANICAL STRENGTH) |
- |
|
|
|
24.16 (MECHANICAL STRENGTH For shroud of portable socket-outlets) |
- |
|
|
|
25.1 (Resistance to heat) |
- |
|
|
|
25.2 (Resistance to heat) |
- |
|
|
|
25.3 (Resistance to heat) |
- |
|
|
|
25.4 (Resistance to heat) |
- |
|
|
|
26.1 (SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
26.2 (SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
26.3 (SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
26.4 (SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
26.5 (SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
26.6 (SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
26.7 (SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
27.1 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
27.2 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
27.3 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
28.1.1 (Glow-Wire Test) |
- |
|
|
|
28.2 (Resistance to Tracking) |
- |
|
|
|
29 (Resistance to Rusting) |
- |
|
|
|
30.1 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES Pressure Test at High Temperature) |
- |
|
|
|
30.2 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES Static Damp Heat Test) |
- |
|
|
|
30.3 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES Tests at Low Temperature) |
- |
|
|
|
30.4 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES Impact Test at Low Temperature) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
|
- |
- Complete Test facility available |
10994 |
BIS, Central Laboratory (CL)
| None
| IS 8183 (1993) |
Bonded mineral wool - Specification (First Revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.10.1 (Resistance to Micro-organisms (Optional)) |
- |
|
|
|
Cl 4.1 (REQUIREMENTS) |
- |
|
|
|
Cl 4.1.1 (REQUIREMENTS) |
- |
|
|
|
Cl 4.2 (REQUIREMENTS) |
- |
|
|
|
4.3 (Recovery After Compression) |
- |
|
|
|
Cl 4.4 (REQUIREMENTS) |
- |
|
|
|
Cl 4.5 (REQUIREMENTS) |
- |
|
|
|
|
- |
- - |
10995 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 398 : Part 5 (1992) |
Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) |
Except Test facility for clause 13.10, 13.11 and 13.12 |
11400 View breakup
Excluding Breaking load on complete conductor, Surface condition test, Corona test and Radio interference test
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7 (elec) (Freedom from
defects) |
- |
|
|
|
13.2 (mech) (Visual Examination) |
- |
|
|
|
13.3 Table-1 (mech) (Diameter-Aluminium wires) |
- |
|
|
|
13.3 Table-2 (mech) (Diameter-Galvanized Steel wires) |
- |
|
|
|
13.5.1 Table 3 (elec) (Breaking Load on Complete conductor) |
- |
|
|
|
13.5.2 Table 1 (mech) (Breaking Load of Aluminium Wires Before Stranding) |
- |
|
|
|
13.5.2 Table 2 (mech) (Breaking Load of Steel Wires Before Stranding) |
- |
|
|
|
13.5.2 Table 2 (mech) (Breaking Load of Steel Wires After Stranding) |
- |
|
|
|
13.6.1 (mech) (Ductility by Torsion Test before stranding) |
- |
|
|
|
13.6.1 (mech) (Ductility by Torsion Test after stranding) |
- |
|
|
|
13.6.2 (mech) (Ductility by Elongation Test before stranding) |
- |
|
|
|
13.6.2 (mech) (Ductility by Elongation Test after stranding) |
- |
|
|
|
13.7.1 (mech) (Wrapping Test Aluminium Wires Before Stranding) |
- |
|
|
|
13.7.1 (mech) (Wrapping Test Aluminium Wires After Stranding) |
- |
|
|
|
13.7.2 (mech) (Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
|
|
|
13.7.2 (mech) (Wrapping Test Galvanized Steel Wires After Stranding) |
- |
|
|
|
13.8 (elec) (Resistance test-Aluminium wire before Stranding) |
- |
|
|
|
14.8 (elec) (Resistance test-Aluminium wire after stranding) |
- |
|
|
|
13.9.2 (chem) (Mass of Zinc coating) |
- |
|
|
|
13.9.2 (chem) (Uniformity of Zinc coating) |
- |
|
|
|
13.4 Table-4 (mech) (Lay Ratio- Aluminium Wire Outermost Layer) |
- |
|
|
|
13.4 Table-4 (mech) (Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
|
|
|
13.4 Table-4 (mech) (Lay Ratio- Aluminium Wire Innermost Layer of Conductors eith 3 Aluminium Wire Layers) |
- |
|
|
|
13.4 Table-4 (mech) (Lay Ratio- Steel Core (6 Wire Layer)) |
- |
|
|
|
10.4 (mech) (Direction of lay) |
- |
|
|
|
13.5.2 Table 1 (mech) (Breaking Load of Aluminium Wires After Stranding) |
- |
|
|
|
|
- |
- Test facility not available:
1. Breaking Load Test on Complete Conductor,
2. Surface conditioning test apparatus
3. Corona Test
4. Radio Interference Voltage Test. |
10996 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 398 : Part 4 (1994) |
Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
- |
Rs 825/- upto 7 wires, Rs 1425/- upto 19 wires View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1 (Freedom from Defects) |
- |
|
|
|
7.1 Table-1 (Dimensional measurement of wires) |
- |
|
|
|
7.2.2 Table-2, Table-4 (Calculated resistance of Stranded Conductor) |
- |
|
|
|
8.1 (Joints in wires-Conductors Containing Seven Wires) |
- |
|
|
|
8.2 (Joints in wires-Conductors Containing More Than Seven Wires) |
- |
|
|
|
9.2 Table 3 (Lay Ratio of stranded conductors) |
- |
|
|
|
9.3 (Direction of Lay) |
- |
|
|
|
9.4 (Multiple layers of wires) |
- |
|
|
|
11 (Packing and Marking) |
- |
|
|
|
12.2 Table 1 (Breaking Load Test- Before Stranding) |
- |
|
|
|
12.2 Table 1 (Breaking Load Test- After Stranding) |
- |
|
|
|
12.3 Table 1 (Elongation Test- Before Stranding) |
- |
|
|
|
12.3 Table 1 (Elongation Test- After Stranding) |
- |
|
|
|
12.4 Table 1 (Resistance of Aluminium wire) |
- |
|
|
|
7.2.1 (Sizes) |
- |
|
|
|
Cl. 7.2 (7.2.1, 7.2.2), Table 2 (Approx Mass) |
- |
|
|
|
|
- |
- Complete Test facility available |
10997 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 398 : Part 1 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) |
- |
Rs.1600/- for 7 strands, Rs.3750/- for 19 strands View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (Freedom from defects) |
- |
|
|
|
9.3 (Stranding) |
- |
|
|
|
12.6, Table 3 (Measurement of lay ratio) |
- |
|
|
|
12.5, Table 1 (Resistance test) |
- |
|
|
|
12.4 (Wrapping test) |
- |
|
|
|
12.3, Table-1 (Breaking load after stranding) |
- |
|
|
|
12.3, Table-1 (Breaking load before stranding) |
- |
|
|
|
12.2, Table-1 (Measurement of diameter of individual aluminium wire) |
- |
|
|
|
7.1.1 (Nominal Sizes) |
- |
|
|
|
7.2.1 (Sizes) |
- |
|
|
|
7.2.2 (Resistance) |
- |
|
|
|
8, 8.1, 8.2 (Joint in wires, except during stranding) |
- |
|
|
|
9.2 (Lay ratio) |
- |
|
|
|
9.4 (Multiple layer of wires) |
- |
|
|
|
|
- |
- Complete Test Facility |
10998 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 651 (2007) |
Glazed stoneware pipes and fittings - Specification (Sixth Revision) |
- |
Rs. 6850/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 7.4 (Acid Resistance Test) |
- |
|
|
|
Clause 7.5 (Alkali Resistance Test) |
- |
|
|
|
7.2 (Hydraulic Test) |
- |
|
|
|
7.3 (Absorption Test) |
- |
|
|
|
11.1-Table 1 (
Mean Thickness of Barrel and of Socket) |
- |
|
|
|
10.1-Table 1 (INTERNAL DIAMETER) |
- |
|
|
|
14-Table 1 (Internal Depth of Socket) |
- |
|
|
|
14-Table 2 (Excess Shoulder Measurment) |
- |
|
|
|
14-Table 3 (Length of Grooving of Spigot) |
- |
|
|
|
12.2 (STRAIGHTNESS OF BARRELS OR STRAIGHT AND TAPER PIPES-Length of Junction) |
- |
|
|
|
13.1-Table 2 (Dimensions of One-Quarter Bends-Internal Diameter) |
- |
|
|
|
13.1-Table 2 (Dimensions of One-Quarter Bends-angle) |
- |
|
|
|
13.1-Table 6 (Dimensions of One-Eighth Taper Bends-D) |
- |
|
|
|
17-Table 10 (Dimensions of Channel Interceptors-A) |
- |
|
|
|
17-Table 10 (Dimensions of Channel Interceptors-G) |
- |
|
|
|
17-Table 11 (Dimensions of Round Mouth Gully traps-Type) |
- |
|
|
|
17-Table 11 (Dimensions of Round Mouth Gully traps-A) |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-G) |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-F') |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-F) |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-E) |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-D) |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-Size) |
- |
|
|
|
14 (The interior of the sockets shall be conical, having a minimum taper) |
- |
|
|
|
13.1-Table 3 (Dimensions of One-Eighth Bends-r) |
- |
|
|
|
13.1-Table 5 (Dimension of One-Quarter Taper Bends-r) |
- |
|
|
|
17-Table 10 (Dimensions of Channel Interceptors-C) |
- |
|
|
|
|
- |
- Test facility is complete for Chemical
Except HST and compression test For size above 300 mm |
10999 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 458 (2003) |
Precast concrete pipes(With And Without Reinforcement) - Specification (Fourth Revision) |
- |
- View breakup
Rs.4200/- (excl. Split tensile strength test, Hydrostatic test, Three edge bearing test and test for aggregates) and testing charges as per relevant referred Iss
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1.1 (a) Identification) |
- |
|
|
|
5.1.1 (b) Date of cast ) |
- |
|
|
|
5.1.1 (c) Date of test ) |
- |
|
|
|
5.1.1 (d) i) Curing-when received dry the specimen shall be kept in water for 24 hr) |
- |
|
|
|
5.1.1 (ii) weight) |
- |
|
|
|
5.1.1 (iv) Cross-sectional area ( in mm2)) |
- |
|
|
|
5.1.1 (v) Max. Load ( in kN) ) |
- |
|
|
|
5.1.1 (vi) Compressive strength, N/mm2 ) |
- |
|
|
|
5.1.1 (vii) Fracture) |
- |
|
|
|
5.1.1 (viii) Individual variation of average ) |
- |
|
|
|
|
- |
- Standard has been revised as IS 458 : 2021 Except three edge load and HST, Split tesnsile and compressive strength upto 1000KN load- |
11000 |
BIS, Central Laboratory (CL)
| None
| IS 2404 (1993) |
Malt extract - Specification (Second Revision) |
- |
Rs 6600/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Table 2 (i) IS 5402:1969 (Total bacterial count) |
- |
|
|
|
Table 2 (ii)IS no 5401 (Coliform bacteria) |
- |
|
|
|
Table 2 (iii) IS no 5403 ( Yeast count, per g) |
- |
|
|
|
Table 2 (iv) IS 5403 (Mould count, per g,) |
- |
|
|
|
|
- |
- - |
11001 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 371 (1999) |
Ceiling roses - Specification (Third Revision) |
6A, 250V |
Rs 5700/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9 (Marking) |
- |
|
|
|
10.1 (Dimentions) |
- |
|
|
|
10.2 (Dimentions) |
- |
|
|
|
11.1 (Accessibility of live parts ) |
- |
|
|
|
11.2 (Accessibility of live parts ) |
- |
|
|
|
11.3 (Accessibility of live parts ) |
- |
|
|
|
11.4 (Accessibility of live parts ) |
- |
|
|
|
11.4.1 (Accessibility of live parts ) |
- |
|
|
|
12.1 (Provision for Earthing) |
- |
|
|
|
12.2 (Provision for Earthing) |
- |
|
|
|
13.1 (Terminals) |
- |
|
|
|
13.2 (Terminals) |
- |
|
|
|
13.3 (Terminals) |
- |
|
|
|
13.4 (Terminals) |
- |
|
|
|
13.5 (Terminals) |
- |
|
|
|
13.6 (Terminals) |
- |
|
|
|
13.7 (Terminals) |
- |
|
|
|
13.8.1 (Terminals) |
- |
|
|
|
13.8.2 (Terminals) |
- |
|
|
|
13.8.3 (Terminals) |
- |
|
|
|
14.1 (Construction) |
- |
|
|
|
14.2 (Construction) |
- |
|
|
|
14.3 (Construction) |
- |
|
|
|
14.4 (Construction) |
- |
|
|
|
15.1 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.2 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.3 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.4 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.5 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.7 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
16 (Temperature Rise Test) |
- |
|
|
|
17 (Temperature Rise Test) |
- |
|
|
|
18 (Resistance to heat) |
- |
|
|
|
19 (Resistance to abnormal heat fire and tracking) |
- |
|
|
|
19.2 (Resistance to abnormal heat fire and tracking) |
- |
|
|
|
20.1 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
20.2 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
20.3 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
21.1 (CREEPAGE DISTANCE AND CLEARANCES) |
- |
|
|
|
22.1 (Resistance to Excessive residual Stress and to Rusting ) |
- |
|
|
|
22.1 (Resistance to Excessive residual Stress and to Rusting ) |
- |
|
|
|
22.1 (Resistance to Excessive residual Stress and to Rusting ) |
- |
|
|
|
|
- |
- - |
11002 |
BIS, Central Laboratory (CL)
| None
| IS 5405 (2019) |
Sanitary napkins – Specification (second revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 7.3.1 (Bacterial and Fungal Bioburden, 7.3.1.1, ISO 11737 (Part 1)) |
- |
|
|
|
Cl7.3.2 (Test for Common Skin Pathogen — Staphylococcus
Aureus, 7.3.2.1, IS 5887 (Part 2)) |
- |
|
|
|
Cl 5 (Absorbent Capacity, Regular ) |
- |
|
|
|
Cl 5 (Absorbent Capacity, Large) |
- |
|
|
|
Cl 5 (Absorbent Capacity, Extra Large) |
- |
|
|
|
Cl 5 (SIZES, XXL) |
- |
|
|
|
Cl 7.1 (pH Value, IS 1390 (cold method) for all sizes) |
- |
|
|
|
Cl 7.2 (Ability to Withstand Pressure after Absorption, for all sizes, Annex B) |
- |
|
|
|
Cl 5 (SIZES, Large) |
- |
|
|
|
Cl 5 (SIZES, Extra Large) |
- |
|
|
|
Cl 5 (SIZES, Regular ) |
- |
|
|
|
|
- |
- - |
11003 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 624 (2003) |
Bicycles - Rims - Specification (Fourth Revision) |
- |
- View breakup
Rs. 2850/- (for manufacture and finish, finish only for Ni/Cr coating thickness) + Material testing charges as per referred ISS.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7 (FINISH) |
- |
|
|
|
3.2 (SHAPES AND DIMENSIONS) |
- |
|
|
|
9 (COMPRESSION TEST) |
- |
|
|
|
7 (chem) (FINISH) |
- |
|
|
|
|
- |
- Except dimensions clause 3.2 & 3.2.1 Circumference, finish test facility only for Ni/Cr coating thickness |
11004 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 204 : Part 1 (1991) |
Tower bolts - Specification: Part 1 ferrous metals (Fifth Revision) |
- |
Rs.2100.00. View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Carbon - IS 228) |
- |
|
|
|
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Manganese - IS 228) |
- |
|
|
|
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Phosphorus - IS 228) |
- |
|
|
|
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Sulphur - IS 228) |
- |
|
|
|
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011) (Chemical composition - Silicon - IS 228) |
- |
|
|
|
6.1- Table 1 (Dimension of Barrel tower bolts-1.Size 2.Length of Bolt-A 3.Length of Barrel-B 4.Width of Barrel-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of mild steel sheet for barrel-F 8.Dia of bore of barrel or socket- G ) |
- |
|
|
|
6.2- Table 2 (Dimension of Sami Barrel Tower Bolts 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of Bolt Plate or Socket-F 8.Dia of bore of Bolt Plate or socket G ) |
- |
|
|
|
6.2- Table 2 (Dimension of Sami Barrel Tower Bolts-Minimum No. of equally Spaced Screw holes in Bolt Plate and Socket for wood screw no 6) |
- |
|
|
|
|
- |
- Test facilities are not available for the following:
(1) Finish |
11005 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 1785 : Part 2 (1983) |
Specification for plain hard drawn steel wire for prestressed concrete: Part 2 as - Drawn wire (First Revision) |
- |
Rs 3000/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5.1 (Diameter) |
- |
|
|
|
Cl 5.1.2 (Weight) |
- |
|
|
|
Cl 6.1 (Tensile Test On UTM) |
- |
|
|
|
Cl 6.3 (Tensile Test On UTM) |
- |
|
|
|
3.1.1 (PHOSPHORUS) |
- |
|
|
|
3.1.1 (SULPHUR) |
- |
|
|
|
Cl. 7.5 (Ductility/ Reverse Bend Test) |
- |
|
|
|
|
- |
- Test facility is complete for Chemical
Except Proof Stress |
11006 |
BIS, Central Laboratory (CL)
| None
| IS 1251 (1988) |
Specification for zinc phosphide, technical |
Technical |
Rs.2300.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
2.1 (Description) |
- |
|
|
|
2.3 (Freedom from sulphides) |
- |
|
|
|
2.2 Table 2 i (Zinc Phosphide (Zn3P2)) |
- |
|
|
|
2.2 Table 2 ii (Zinc Content) |
- |
|
|
|
2.2 Table 2 iii (Sieving Requirements: Material passing through 150 micron IS Sieve) |
- |
|
|
|
2.2 Table 2 iv (Sieving Requirements: Material passing through 106 micron IS Sieve) |
- |
|
|
|
|
- |
- - |
11007 |
BIS, Central Laboratory (CL)
| None
| IS 261 (1982) |
Specification for copper sulphate (Second Revision) |
- |
- View breakup
Rs 2400/- for Tech., Rs 3900/- for Pure
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
1(i) Table 1 (Copper, Tech, A-2) |
- |
|
|
|
1(i) Table 1 (Copper, Pure, A-2) |
- |
|
|
|
1(ii) Table 1 (Matter insoluble in water, Tech, A-3) |
- |
|
|
|
1(ii) Table 1 (Matter insoluble in water, Pure, A-3) |
- |
|
|
|
1(iii) Table 1 (Soluble iron and aluminium compounds ( as Fe ), Pure, A-4) |
- |
|
|
|
1(iv) Table 1 (pH value, Tech, A-5) |
- |
|
|
|
1(iv) Table 1 (pH value, Pure, A-5) |
- |
|
|
|
1(v) Table 1 (Chloride ( as Cl ), Tech, A-6) |
- |
|
|
|
1(v) Table 1 (Chloride ( as Cl ), Pure, A-6) |
- |
|
|
|
1(vi) Table 1 (Arsenic ( as As2O3 ), Tech, A-7) |
- |
|
|
|
1(vi) Table 1 (Arsenic ( as As2O3 ), Pure, A-7) |
- |
|
|
|
1(vii) Table 1 (Lead and zinc, Tech, A-8) |
- |
|
|
|
1(vii) Table 1 (Lead and zinc, Pure, A-8) |
- |
|
|
|
Cl 3.1 (Description, Tech and Pure) |
- |
|
|
|
|
- |
- Facility is complete for this IS;
Excluding NA |
11008 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 1729 (2002) |
Cast iron/ductile iron drainage pipes and pipe fittings for over ground non-pressure pipeline socket and spigot series (Second Revision) |
- |
Rs. 2850/- and testing charges as per referred Iss View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1 (Tensile Strrngth - IS1608(Pt-1)) |
- |
|
|
|
5.1 (Elongation - IS 1608(Pt-1)) |
- |
|
|
|
5.4 (Hardness- IS 1500) |
- |
|
|
|
7 (Leakage Test - IS 1729) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, a) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, b) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, c) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, d) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, e) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, f) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, g) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, h) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, i) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, j) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, k) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, l) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, m) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, n) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, p) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, q) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, r) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, r1) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, r2) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, s) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, t) |
- |
|
|
|
11 (Coating Test at 65degree Celcius ) |
- |
|
|
|
11 (Coating Test at 0degree Celcius) |
- |
|
|
|
5.3 (Casting Defects) |
- |
|
|
|
|
- |
- Test facility is complete and Standard has been revised as IS 1729 : 2023
Facility for chemical testing is not available |
11009 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 1489 : Part 2 (2015) |
Portland - Pozzolana cement - Specification: Part 2 calcined clay based |
- |
Rs.8420/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 - Table - 1 i (Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 ii (Magnesia - Cl 7.2 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 iii (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 v (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 vi ( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
|
|
|
7 -Table 2- i (Fineness 4031 Part 2) |
- |
|
|
|
7 -Table 2- ii- a (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
7 -Table 2- ii- a (Expansion after aeration - 4031 Part 3) |
- |
|
|
|
7 -Table 2- ii- b (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
7 -Table 2- ii- b (Expansion after aeration- 4031 Part 3) |
- |
|
|
|
7 -Table 2- iii- a (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
7 -Table 2-iii- b (Setting Time Final- 4031 Part 5) |
- |
|
|
|
7 -Table 2- iv- a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
7 -Table 2- iv- b (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
7 -Table 2- iv- c (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
7 -Table 2- vi (Drying Shrinkage- IS 4031 Part 10) |
- |
|
|
|
|
- |
- Test facility is complete for Chemical Except Transverse Strength Test |
11010 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 2255 (1977) |
Specification for mild steel wire rod for the manufacture of machine screws (By Cold Heading Process) (Second Revision) |
- |
Rs. 600/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7 (Sizes and tolernces) |
- |
|
|
|
8 (FREEDOM FROM DEFECTS) |
- |
|
|
|
|
- |
- Test facility is complete for Chemical,Tensile test,Microaalloying Element |