| 11041 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 277 (2018) |
Galvanized steel strips and sheets (Plain And Corrugated) - Specification (Seventh Revision) |
All Type |
4600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8.1(UTM) |
- |
1500 |
|
- |
| Cl 8.2(Press) |
- |
500 |
|
- |
| Cl 10(Galvanising Test) |
- |
500 |
|
- |
| Cl 12(Workmanship) |
- |
200 |
|
- |
| Cl 13(Weight) |
- |
300 |
|
- |
| Cl 14(Length, Width & Thickness) |
- |
600 |
|
- |
| 7.4(Mass of Coating: Single Spot Test) |
- |
1000 |
|
- |
| 7.4(Mass of Coating: Triple Spot Test) |
- |
1000 |
|
- |
| 7.1 & 10.2(Mass of Coating: Single Spot Test) |
- |
1000 |
|
- |
| 7.1 & 10.2(Mass of Coating: Triple Spot Test) |
- |
1000 |
|
- |
| 5.1(phosphorus) |
- |
300 |
|
- |
| 5.1(copper) |
- |
300 |
|
- |
| 5.1(nitrogen) |
- |
300 |
|
- |
| 5.1(micro alloy) |
- |
300 |
|
- |
| 5.1(aluminium) |
- |
300 |
|
- |
| 5.1(silicon ) |
- |
300 |
|
- |
| 5.1(manganese) |
- |
300 |
|
- |
| 5.1(sulphur) |
- |
300 |
|
- |
| 5.1(carbon) |
- |
300 |
|
- |
| Cl. 14 & Cl. 15(Pitch of corrugation (average of 4)) |
- |
200 |
|
- |
| Cl. 14 & Cl. 15(Depth of corrugation (average of 4)) |
- |
200 |
|
- |
| Cl. 14 & Cl. 15 (Cl. 14 & Cl 15 (Number of Corrugation)) |
- |
200 |
|
- |
| Cl. 14 & Cl. 15 (Cl. 14 & Cl 15 (Difference between Diagonal)) |
- |
200 |
|
- |
| Cl. 14 & Cl. 15 (Cl. 14 & Cl. 15 (Thickness)) |
- |
200 |
|
- |
| Cl. 14 (Cl. 14 & Cl 15 (Width)) |
- |
200 |
|
- |
| Cl. 14 (Cl. 14 & Cl 15 (Length)) |
- |
200 |
|
- |
| Cl.12(Freedom from defects) |
- |
200 |
|
- |
| Cl. 8.1 (Cl. 8.1 (Percentage Elongation )) |
- |
1000 |
|
- |
| Cl. 8.1 (Cl. 8.1 (Yield Stress)) |
- |
1000 |
|
- |
| Cl. 8.1 (Cl. 8.1 (Tensile Strength)) |
- |
1000 |
|
- |
| cl 5.1, T-1, Note-5, For Microalloying elements(Nb+V+Ti+B) |
- |
300 |
|
- |
| cl 5.1, T-1, Note-5, For Microalloying elements(B) |
- |
300 |
|
- |
| cl 5.1, T-1, Note-5, For Microalloying elements(Ti) |
- |
300 |
|
- |
| cl 5.1, T-1, Note-5, For Microalloying elements(V) |
- |
300 |
|
- |
| cl 5.1, T-1, Note-5, For Microalloying elements(Nb) |
- |
300 |
|
- |
| cl 5.1, T-1, Note-4, For Cu bearing quality(Cu) |
- |
300 |
|
- |
| cl 5.1, T-1, Note-2, When Al-Si killed(Si) |
- |
300 |
|
- |
| cl 5.1, T-1, Note-2, When Si killed(Si) |
- |
300 |
|
- |
| cl 5.1, T-1, Note-2, When Al killed(Al) |
- |
300 |
|
- |
| Cl. 9(Surface roughness) |
- |
200 |
|
- |
| 7.6(Coating finish type) |
- |
200 |
|
- |
| 8.3(Bend test miniral diameter) |
- |
500 |
|
- |
|
- |
- - |
| 11042 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 12818 (2010) |
Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) |
All Type |
17750 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.6(Vicat Softening Temperature
IS 12235 (Part 2).) |
- |
1500 |
|
- |
| 9.5(Tensile Strength
IS 12235(Part 13)) |
- |
1500 |
|
- |
| 9.4 and Table 14(Resistance to External Blows at 0 ?C
IS 12235 (Part 9)) |
- |
1500 |
|
- |
| 9.3(Density
IS 12235 (Part 14)) |
- |
750 |
|
- |
| 9.1( Visual Appearance) |
- |
500 |
|
- |
| 9.2(Internal Diameter) |
- |
300 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
300 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
300 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
300 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
300 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
300 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
300 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
300 |
|
- |
| 8.4(Sealing rings - Hardness) |
- |
1000 |
|
- |
| 8.1 to 8.3 and Table 11 &12
Fig 3A & 4A(THREADING OF SCREEN ANDCASING PIPES.
IS 554.) |
- |
300 |
|
- |
| 8.1 to 8.3 and Table 11 &12
Fig 3A & 4A(THREADING OF SCREEN ANDCASING PIPES.
IS 554.) |
- |
300 |
|
- |
| 7.5 and Table 10
Fig 2A & 2B(Approximate Free Passage Area, in Percent (Mean Value) for Width of Slot (w)) |
- |
300 |
|
- |
| 7.5 and Table 10
Fig 2A & 2B(Minimum number of slots on the circumference of the cross-section.) |
- |
300 |
|
- |
| 7.5 and Table 10
Fig 2A & 2B(Summation of slot lengths over internal circumference of the cross- section.) |
- |
300 |
|
- |
| 7.4 Table 8 & 9 Fig 1(Segmental length for Spigot (average of 4.0)) |
- |
300 |
|
- |
| 7.4 Table 8 & 9 Fig 1(Segmental length,mm for socket (average of 4.0)) |
- |
300 |
|
- |
| 7.4 Table 8 & 9
Fig 1(Segmental length, l3) |
- |
300 |
|
- |
| 7.4 Table 8 & 9
Fig 1(Effective length, l2) |
- |
300 |
|
- |
| 7.3.2(Rib height) |
- |
300 |
|
- |
| 7.3.1(No.of Ribs) |
- |
300 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(Wall thickness, Max) |
- |
300 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(Wall thickness, Min) |
- |
300 |
|
- |
| 7.1, 7.2 and Table 5, 6 & 7 Fig 1B(Mean outside dia over connection,mm (Take 4 reading and maximum valu reported)) |
- |
300 |
|
- |
| 7.1, 7.2 and Table 5, 6 & 7 Fig 1B(Outer Diameter at any point, Max) |
- |
300 |
|
- |
| 7.1, 7.2 and Table 5, 6 & 7 Fig 1B(Outer Diameter at any point , Min) |
- |
300 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(Mean Outer Diameter of Pipe , Max) |
- |
300 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(Mean Outer Diameter of Pipe, Min) |
- |
300 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(Nominal Diameter) |
- |
300 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(DIMENSIONS - Casing Pipes) |
- |
300 |
|
- |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Wall thickness) |
- |
300 |
|
- |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Mean Outer Diameter over Connection) |
- |
300 |
|
- |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Outer Diameter at any point ) |
- |
300 |
|
- |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Mean Outer Diameter of Pipe) |
- |
300 |
|
- |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Nominal Diameter) |
- |
300 |
|
- |
| 4.1.2 (Ref. Cl 11 of IS 4669)(Composition -Sulphated ash content ) |
- |
1200 |
|
- |
| 4.1.2 (Ref. Cl 5.1. of IS 4669)(Composition - Loss on heating ) |
- |
500 |
|
- |
| 4.1.1 (Ref. 3.4.1. of IS 10151)(Composition - The monomer content (VCM content) in the
resin - Annex A ofIS 10151) |
- |
1500 |
|
- |
| 5(COLOUR) |
- |
200 |
|
- |
| 8.4(Sealing elements
a. Elastomeric material
b. Shore A hardness of sealing Elements
) |
- |
2000 |
|
- |
| 8.4(Width b) |
- |
300 |
|
- |
| 8.3.1
&
8.3.2
(Threading of casing pipe (from 100 to 200 DN Table – 11 & Fig. 3A) & (from 250 to 400 DN Table – 12 & Fig. 4A)
Outside diameter
d1(+0, -0.3)
d2
d3
D1 (+0.3, -0)
D2
D4
D5 (+0.3, -0)
Z
h3 (+0, -0.1)
H4 (+0, -0.1)
) |
- |
300 |
|
- |
| 8.2(Threading of casing pipe As per IS 554 (from 40 to 80mm DN)
Number of threads in 25.4mm
Pitch (P)
Height of thread (h)
Major (Gauge Diameter) d
Pitch(d2)
Minor (d1)
External Thread gauge length
Nominal
No. of turns of thread
max
min
) |
- |
300 |
|
- |
| 7.5.1
7.5.2
(Slot Dimension (Table 10) Fig 2A & 2B
a. Minimum number of slot on the circumference
b. Σa±5%
c. Mean value of approximate free passage area (%) for width of slot (w)
d. Tolerance on width of slot (w)
e. Width of material between slot (b)) |
- |
300 |
|
- |
| 5.0(Colour of Pipes) |
- |
200 |
|
- |
| 9.7(Effect on Water
a) Lead (first extraction)
b) Lead (Third extraction)
c) Dialkyl Tin C4 & higher homologues measured as Tin (Third extraction)
d) Cadmium (All three extracts)
e) Mercury (All three extracts)
f) Other Toxic Substances
) |
- |
7500 |
|
- |
| 4.1.2(K-Value as per IS-4669) |
- |
5000 |
|
- |
| 4.1.1
(VCM Content as per IS 10151 (Annex A)) |
- |
2000 |
|
- |
| 7.1(Screen Pipes) |
- |
300 |
|
- |
| 11(Marking) |
- |
200 |
|
- |
| 5.1(Materials) |
- |
10000 |
|
- |
|
- |
- - |
| 11043 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 14887 (2014) |
Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sacks for packaging of 50 kg food grains – Specification (first revision) |
All Type |
15700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2(Tapes – Width and Thickness
( IS 6192/IS 11197)) |
- |
100 |
|
- |
| 3.2(Tapes – Linear Density
(IS 6192/IS 11197)) |
- |
100 |
|
- |
| 3.2(Tapes – Tenacity (IS 6192/IS 11197)) |
- |
100 |
|
- |
| 3.2(Tapes – Elongation at point of rupture
(IS 6192/IS 11197)) |
- |
1000 |
|
- |
| 3.2(Tapes – Heat Shrinkage (HDPE) (Cl. 3.2 and IS 6192)) |
- |
800 |
|
- |
| 3.2(Tapes – Colour Fastness for pigmented tapes (IS 6192/IS 11197)) |
- |
500 |
|
- |
| 3.2(Tapes – Dimensional stability (PP)
(IS 11197)) |
- |
500 |
|
- |
| 3.3.1(Bottom seam (IS 10789)) |
- |
200 |
|
- |
| 4.1 and 3.4(Mass of bale (Cl. 4.1), Capacity (Cl 3.4)) |
- |
200 |
|
- |
| 4.2 and Table 1 ii(Dimensions ) |
- |
200 |
|
- |
| 5.2 and Table 1 iii(Ends per dm ) |
- |
100 |
|
- |
| 5.2 and Table 1 iv(Picks per dm ) |
- |
100 |
|
- |
| 4.2 and Table 1 v(Mass of sack ) |
- |
500 |
|
- |
| 4.2 and Table 1 vi(Average breaking strength of fabric ) |
- |
1000 |
|
- |
| 4.2 and Table 1 vi(Breaking strength of bottom seam ) |
- |
1000 |
|
- |
| 4.2 and Table 1 viii(Elongation at break of fabric ) |
- |
1000 |
|
- |
| 4.2 and Table 1 ix(Average breaking strength and elongation at break of UV stabilized HDPE/PP fabric after been exposed to UV radiation and weathering ) |
- |
8500 |
|
- |
| 4.2 and Table 1 x(Ash content ) |
- |
800 |
|
- |
| 3.1(Material Identification) |
- |
3500 |
|
- |
| 3.1(Overall Migration) |
- |
2500 |
|
- |
| 3.2(Density) |
- |
750 |
|
- |
| 3.2(MFI) |
- |
1200 |
|
- |
|
- |
- - |
| 11044 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 14252 (2015) |
Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sack for filling sand – Specification (second revision) |
All Type |
15400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Raw Material) |
- |
2500 |
|
- |
| 3.2(Tapes – Width
) |
- |
100 |
|
- |
| 3.2(Tapes – Linear Density
) |
- |
750 |
|
- |
| 3.3(Tying Cord) |
- |
250 |
|
- |
| 3.4(Sack) |
- |
400 |
|
- |
| 3.4.1(Seam) |
- |
250 |
|
- |
| 4.1 and Table 1 i a(Dimensions Outside Length) |
- |
200 |
|
- |
| 4.1 and Table 1 i b(Dimensions Outside Width) |
- |
200 |
|
- |
| 4.1 and Table 1 ii(Ends per dm ) |
- |
200 |
|
- |
| 4.1 and Table 1 iii(Picks per dm ) |
- |
200 |
|
- |
| 4.2 and Table 1 iv(Mass of sack
) |
- |
500 |
|
- |
| 4.1 and Table 1 v a(Average breaking strength of fabric Warpway
) |
- |
1000 |
|
- |
| 4.1 and Table 1 v b(Average breaking strength of fabric Weftway
) |
- |
1000 |
|
- |
| 4.1 and Table 1 vi(Average Breaking strength of bottom seam ) |
- |
1000 |
|
- |
| 4.1 and Table 1 vii a(Elongation at break of fabric Lengthwise) |
- |
1000 |
|
- |
| 4.1 and Table 1 vii b(Elongation at break of fabric Widthwise ) |
- |
1000 |
|
- |
| 4.1 and Table 1 viii(Average breaking strength and elongation at break of UV stabilized HDPE/PP fabric after been exposed to UV radiation and weathering ) |
- |
8500 |
|
- |
| 4.1 and Table 1 ix(Ash content ) |
- |
800 |
|
- |
|
- |
- - |
| 11045 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 16208 (2015) |
Textiles - High density polyethylene (HDPE)/polypropylene (PP) woven sacks for packaging 10 kg, 15 kg, 20 kg, 25 kg and 30 kg foodgrains - Specification |
All TYpe |
14800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(TYPES) |
- |
200 |
|
- |
| 4.1(Raw Material) |
- |
2500 |
|
- |
| 4.2(Tapes – Width
IS 6192 and IS 11197) |
- |
200 |
|
- |
| 4.2(Tapes – Linear Density
) |
- |
700 |
|
- |
| 4.2(Construction) |
- |
200 |
|
- |
| 4.3(Sacks) |
- |
200 |
|
- |
| 4.3.1(Bottom Seam) |
- |
500 |
|
- |
| 4.3.1( The two rows of stitches shall be separated from each other) |
- |
200 |
|
- |
| 4.3.1( The outer stitch) |
- |
200 |
|
- |
| 4.3.1( The stitching shall be done with double fold over seam to a depth ) |
- |
500 |
|
- |
| 4.3.1(Stitches pass through a minimum of six layers of the fabric. ) |
- |
500 |
|
- |
| 4.3.1(The number of stitches/dm) |
- |
200 |
|
- |
| 4.3.2(Mouth) |
- |
0 |
|
- |
| 4.4 and Table 1 i(Capacity) |
- |
200 |
|
- |
| 5.2 and Table 1 ii a(Dimensions Inside Length) |
- |
200 |
|
- |
| 5.2 and Table 1 ii b(Dimensions Inside Width) |
- |
200 |
|
- |
| 5.2 and Table 1 iii(Ends per dm ) |
- |
200 |
|
- |
| 5.2 and Table 1 iv(Picks per dm ) |
- |
200 |
|
- |
| 5.1 and Table 1 v(Mass of sack ) |
- |
500 |
|
- |
| 5.2 and Table 1 vi a(Average breaking strength of fabric Lengthwise ) |
- |
1000 |
|
- |
| 5.2 and Table 1 vi b(Average breaking strength of fabric Widthwise ) |
- |
1000 |
|
- |
| 5.2 and Table 1 vi(Breaking strength of bottom seam ) |
- |
1000 |
|
- |
| 5.2 and Table 1 viii a(Elongation at break of fabric Lengthwise) |
- |
1000 |
|
- |
| 5.2 and Table 1 viii b(Elongation at break of fabric Widthwise ) |
- |
1000 |
|
- |
| 5.2 and Table 1 ix(Average breaking strength and elongation at break of UV stabilized HDPE/PP fabric after been exposed to UV radiation and weathering ) |
- |
8500 |
|
- |
| 5.2 and Table 1 x(Ash content ) |
- |
800 |
|
- |
|
- |
- - |
| 11046 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 2508 (2016) |
Polyethylene films and sheets - Specification (Third Revision) |
All Type |
15650 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.1(Appearance) |
- |
200 |
|
- |
| 5.1.2(Film Form) |
- |
200 |
|
- |
| 5.1.3(Odour) |
- |
500 |
|
- |
| 5.1.4(Density, Cl.5 of IS 13360(Part-3/Section-1)) |
- |
750 |
|
- |
| 5.1.5(Melt Flow Index. Cl 6, 7 of IS 13360(Part-4/Section-1)) |
- |
1500 |
|
- |
| 5.1.6a(Carbon Black Content, Annex-A) |
- |
1000 |
|
- |
| 5.1.6b(Ash Content, Annex-A) |
- |
750 |
|
- |
| 5.1.6c(Carbon Black Dispersion, Cl.16 of IS 2530) |
- |
1000 |
|
- |
| 5.2.2(Tolerance on Thickness, Annex-A) |
- |
250 |
|
- |
| 6.1, Table 1(Tensile strength at break. A) Machine Direction. IS 13360 (Part 5/Sec 1)) |
- |
1000 |
|
- |
| 6.1, Table 1(Tensile strength at break. B) Transverse Direction. IS 13360 (Part 5/Sec 3)) |
- |
1000 |
|
- |
| 6.1, Table 1(Ageing test at (70-1)c for 7 days , cl 4 IS 7016 ) |
- |
2500 |
|
- |
| 6.1, Table 1(Elongation at break ,A) Machine direction .IS 13360(Part-5/sec-1) ) |
- |
1000 |
|
- |
| 6.1, Table 1(Elongation at break ,B) Cross-machine direction..IS 13360(Part-5/sec-3) ) |
- |
1000 |
|
- |
| 6.1, Table 1(Dartimpact strength Method B of IS 13360 (Part-5/sec-6) ) |
- |
800 |
|
- |
| 6.1, Table 1(Tear resistence. A) Machine direction Annex B) |
- |
2000 |
|
- |
| 6.1, Table 1(Tear resistence. B) Transverse direction ) |
- |
2000 |
|
- |
| 7.1. Table 2(Tensile strength at break A) Machine direction IS 13360 (Part-5/sec-1) ) |
- |
1000 |
|
- |
| 7.1. Table 2(Tensile strength at break,B) Crosse machine direction IS 13360 (Part-5/sec-3) ) |
- |
1000 |
|
- |
| 7.1. Table 2(Ageing test at (70-1)c for 7 days , cl 4 IS 7016 ) |
- |
2500 |
|
- |
| 7.1. Table 2(Elongation at break , A) Machine direction IS 13360 (Part-5/sec-3) IS 13360 (Part-5/sec-1) ) |
- |
1000 |
|
- |
| 7.1. Table 2(Elongation at break , A) Transverse direction IS 13360 (Part-5/sec-3) ) |
- |
1000 |
|
- |
| 7.1. Table 2(Dart impact strenght , Method A of IS 3360 (Part-5/sec-6) ) |
- |
800 |
|
- |
| 8.1, Table 3(Tensile properties ,A) Yield strenght . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1000 |
|
- |
| 8.1, Table 3(Tensile properties , B) Break strenght . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1000 |
|
- |
| 8.1, Table 3(Tensile properties ,C) Yield elongation . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1000 |
|
- |
| 8.1, Table 3(Tensile properties ,D) Break elongation . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1000 |
|
- |
| 8.1, Table 3(Tear resistance , Annex B) |
- |
2000 |
|
- |
| 8.1, Table 3(Puncture resistance , Annex C) |
- |
1500 |
|
- |
| 9.1, Table 4(Tensile properties ,A) Yield strenght . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1000 |
|
- |
| 9.1, Table 4(Tensile properties , B) Break strenght . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1000 |
|
- |
| 9.1, Table 4(Tensile properties ,C) Yield elongation . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1000 |
|
- |
| 9.1, Table 4(Tensile properties ,D) Break elongation . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1000 |
|
- |
| 9.1, Table 4(Tear resistance , Annex B) |
- |
2000 |
|
- |
| 9.1, Table 4(Puncture resistance , Annex C) |
- |
1500 |
|
- |
| Clause 7.1(Table 2)(Decrease in Tensile Strength after Ageing(Transverse Direction)) |
- |
2500 |
|
- |
| Clause 7.1(Table 2)(Decrease in Tensile Strength after Ageing(Machine Direction)) |
- |
2500 |
|
- |
| Clause 6.1(Table 1)(Decrease in Tensile Strength after Ageing(Transverse Direction)) |
- |
2500 |
|
- |
| Clause 6.1(Table 1)(Decrease in Tensile Strength after Ageing(Machine Direction)) |
- |
2500 |
|
- |
| Clause 5.2.3(Tolerance on Width) |
- |
250 |
|
- |
| Cl.5.1.6(a)(Carbon Black Content) |
- |
1000 |
|
- |
| Cl.5.1.6(b)(Ash content) |
- |
750 |
|
- |
| Cl.5.1.6(c)(Dispersion of Carbon Black) |
- |
1000 |
|
- |
| 5.2.1.1(Nominal Thickness) |
- |
250 |
|
- |
| 5.2.1.2(Nominal width) |
- |
250 |
|
- |
|
- |
- - |
| 11047 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 12701 (1996) |
Rotational moulded polyethylene water storage tanks - specification (First Revision) |
All Type |
18500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2.3(Carbon Black Content ) |
- |
1000 |
|
- |
| 4.2.3(Carbon Dispersion Test) |
- |
1000 |
|
- |
| 5(Types and Features ) |
- |
500 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
700 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
700 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
700 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
700 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
700 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
700 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
700 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
700 |
|
- |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
700 |
|
- |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
700 |
|
- |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
700 |
|
- |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
700 |
|
- |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
700 |
|
- |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
700 |
|
- |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
700 |
|
- |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
700 |
|
- |
| 5.3(Types and Features ) |
- |
500 |
|
- |
| 5.6(Types and Features ) |
- |
500 |
|
- |
| 6.1(Finish) |
- |
300 |
|
- |
| 7.1.1(Resistance to Deformation) |
- |
2000 |
|
- |
| 7.1.2(Resistance to Deformation) |
- |
2000 |
|
- |
| 7.2(Resistance to Impact) |
- |
2000 |
|
- |
| 7.3(Test for Top Load Resistance) |
- |
2000 |
|
- |
| 7.4(Tensile Strength) |
- |
1500 |
|
- |
| 7.5(Flexural Modulus) |
- |
1500 |
|
- |
| 7.6(overall Migration) |
- |
2500 |
|
- |
| 9.2(Man-Hole and Hand-Hole Lids) |
- |
700 |
|
- |
| 9.1(Man-Hole and Hand-Hole Lids) |
- |
700 |
|
- |
| 9.1(Lid Thickness) |
- |
700 |
|
- |
| 7.3(Test for Top Load Resistance) |
- |
2000 |
|
- |
| 5.4(Wall Thickness above effective height) |
- |
700 |
|
- |
| 5.2 Table 2 (7)(Minimum Wall Thickness) |
- |
700 |
|
- |
| 5.1 Table 1 (7)(Minimum Weight of Tank (Without Lid)) |
- |
700 |
|
- |
| 4.2.1(Density) |
- |
1000 |
|
- |
| 4.2.2(MFI) |
- |
1500 |
|
- |
| 7.6(overall Migration) |
- |
2500 |
|
- |
| 4.1(MATERIALS) |
- |
10000 |
|
- |
| 10(MARKING) |
- |
200 |
|
- |
|
- |
- - |
| 11048 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 6240 (2008) |
Hot rolled steel plate (Up To 6 Mm) sheet and strip for the manufacture of low pressure liquefiable gas cylinders (Fourth Revision) |
All Type |
14200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 7(UTM) |
- |
1500 |
|
- |
| Cl 8(Press) |
- |
1000 |
|
- |
| Cl 9(Strainage Embrittlement) |
- |
3500 |
|
- |
| Cl 10(Erichsen Cupping) |
- |
1500 |
|
- |
| Cl 13(Length, Width & Thickness) |
- |
600 |
|
- |
| 6.1(Carbon %) |
- |
300 |
|
- |
| 6.1(Manganese %) |
- |
300 |
|
- |
| 6.1(Phosphorus %) |
- |
300 |
|
- |
| 6.1(Sulphur %) |
- |
300 |
|
- |
| 6.1(Silicon %) |
- |
300 |
|
- |
| 6.1(Nitrogen%) |
- |
300 |
|
- |
| 6.1( Aluminium %) |
- |
300 |
|
- |
| Cl. 13(Out of square) |
- |
200 |
|
- |
| Cl. 13(Flatness) |
- |
500 |
|
- |
| Cl. 13(Camber) |
- |
500 |
|
- |
| Cl. 13(Width) |
- |
200 |
|
- |
| Cl. 13(Thickness) |
- |
200 |
|
- |
| Cl. 12(Freedom from defects) |
- |
200 |
|
- |
| Cl. 7.2 Table 3(Elongation) |
- |
1000 |
|
- |
| Cl. 7.2 Table 3(Yield Stress) |
- |
1000 |
|
- |
| 13(Length - SOP MT-23) |
- |
200 |
|
- |
| 13(Mass) |
- |
500 |
|
- |
| 15(Marking) |
- |
200 |
|
- |
|
- |
- - |
| 11049 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 15647 (2006) |
Hot rolled steel narrow width strip for welded tubes and pipes |
All Type |
10600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8(UTM) |
- |
1500 |
|
- |
| Cl 9(Press) |
- |
1000 |
|
- |
| Cl 11(Workmanship) |
- |
500 |
|
- |
| Cl 12(Length, Width & Thickness) |
- |
600 |
|
- |
| Cl 13(Workmanship) |
- |
500 |
|
- |
| Cl. 12(Weight) |
- |
500 |
|
- |
| Cl. 12(Edge Camber) |
- |
750 |
|
- |
| Cl. 12(Thickness) |
- |
200 |
|
- |
| Cl. 8.2 Table 3(Elongation) |
- |
1000 |
|
- |
| Cl. 8.2 Table 3(Yield Stress) |
- |
1000 |
|
- |
| 8(Tensile Strength-IS:1608(P1)) |
- |
1500 |
|
- |
| 8(Yield Strength-IS:1608(P1)) |
- |
1000 |
|
- |
| 8(Elongation -IS:1608(P1)) |
- |
1000 |
|
- |
| 8.0(Bend test IS 1599:1985) |
- |
1000 |
|
- |
| 9.0(Bend Test IS 1599:1985) |
- |
1000 |
|
- |
| 7(Carbon as C - IS:228) |
- |
300 |
|
- |
| 7(Manganese as Mn-IS:228) |
- |
300 |
|
- |
| 7(Sulphur as S- IS:228) |
- |
300 |
|
- |
| 7(Phosphorus as P-IS:228) |
- |
300 |
|
- |
| 7(Aluminium -IS:228) |
- |
300 |
|
- |
| 7(Silicon as S-IS:228) |
- |
300 |
|
- |
| 7(Nitrogen content -IS:228) |
- |
300 |
|
- |
| 7(Chromium IS 8811: 1998) |
- |
300 |
|
- |
| 7(Nickel IS 8811: 1998) |
- |
300 |
|
- |
| 7(Boron IS 8811: 1998) |
- |
300 |
|
- |
| 7(Titanium IS 8811: 1998) |
- |
300 |
|
- |
| 7(Niobium IS 8811: 1998) |
- |
300 |
|
- |
| 7(Vanadium IS 8811: 1998) |
- |
300 |
|
- |
| 7(Copper IS 8811: 1998) |
- |
300 |
|
- |
| 5.2(Molybednum Astime 1086: 2014) |
- |
300 |
|
- |
| 12.0(Dimention IS 1730:1989) |
- |
600 |
|
- |
|
- |
- - |
| 11050 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 2185 : Part 3 (1984) |
Concrete Masonry Units Part 3 Autoclaved Cellular Aerated Concrete Blocks |
All Type |
27500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8(Physical requirments) |
- |
0 |
|
- |
| 8.2(Physical requirments-Dimensions-Length) |
- |
500 |
|
- |
| 8.2(Physical requirments-Dimensions-Height) |
- |
500 |
|
- |
| 8.2(Physical requirments-Dimensions-Width) |
- |
500 |
|
- |
| 8.3(Physical requirments- Block density) |
- |
1000 |
|
- |
| 8.4(Physical requirments- Compressive strength) |
- |
4500 |
|
- |
| 8.5(Thermal Conductivity) |
- |
15000 |
|
- |
| 8.6( Drying Shrinkage ) |
- |
5500 |
|
- |
| 8.4, 9.2 & 11.3(Indivisual Moisture Content) |
- |
1000 |
|
- |
| 8.4, 9.2 & 11.3(Indivisual Bulk density) |
- |
500 |
|
- |
| 8.4, 9.2 & 11.3 & Table 1(Indivisual Compressive strength) |
- |
2000 |
|
- |
| 8.3 & 9.1(Indivisual Moisture Content) |
- |
1000 |
|
- |
| 8.3 & 9.1 Table 1(Indivisual Block Density) |
- |
1000 |
|
- |
| 3.2 & 8.2(Indivisual Height) |
- |
500 |
|
- |
| 3.2 & 8.2(Indivisual Width) |
- |
500 |
|
- |
| 3.2 & 8.2(Indivisual Length) |
- |
500 |
|
- |
| 8.6, 9.4 & 11.5(Grade) |
- |
500 |
|
- |
| 3.4(Special Faces) |
- |
500 |
|
- |
| 3.3(Faces & Arises) |
- |
500 |
|
- |
| 3.1(Shape) |
- |
500 |
|
- |
| 8.1.1(General (Exposed wall construction)) |
- |
500 |
|
- |
| 7(SURFACE TEXTURE AND FINISH) |
- |
500 |
|
- |
| 9.3(Thermal Conductivity) |
- |
15000 |
|
- |
| 15(Marking) |
- |
500 |
|
- |
|
- |
- - |
| 11051 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 2185 : Part 2 (1983) |
Specification for concrete masonry units: Part 2 hollow and solid lightweight concrete blocks (First Revision) |
All Type |
17500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.7(Moisture Movement) |
- |
2500 |
|
- |
| 8.6(Drying shrinkage) |
- |
5500 |
|
- |
| 8.5, Table 1(Water Absorption) |
- |
1000 |
|
- |
| 8.4, Table 1(Compressive strength) |
- |
4500 |
|
- |
| 8.3(Block Density) |
- |
1000 |
|
- |
| 3.2.5(Thickness of Web) |
- |
500 |
|
- |
| 3.2.5(Face Shell Thickness) |
- |
500 |
|
- |
| 3.2(Width) |
- |
500 |
|
- |
| 3.2(Height) |
- |
500 |
|
- |
| 8.1(General) |
- |
500 |
|
- |
| 8.2(Deimension (Length)) |
- |
500 |
|
- |
| 8.2(Deimension (Height)) |
- |
500 |
|
- |
| 8.2(Deimension (Width)) |
- |
500 |
|
- |
| 8.3(Block Density) |
- |
1000 |
|
- |
| 8.4(Compressive Strength) |
- |
4500 |
|
- |
| 8.5(Water Absorption) |
- |
1000 |
|
- |
| 8.6(Drying Shrinkage) |
- |
5500 |
|
- |
| 8.7(Moisture Movement) |
- |
3000 |
|
- |
|
- |
- - |
| 11052 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 2185 : Part 1 (2005) |
Concrete masonry units - Specification: Part 1 hollow and solid concrete blocks (Third Revision) |
All Type |
18500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.1(PHYSICAL REQUIREMENTS-General) |
- |
1000 |
|
- |
| 9.2 & 4.2(PHYSICAL REQUIREMENTS-Nominal Dimensions 1.Length 2.Hight 3. Width) |
- |
1000 |
|
- |
| 9.2 & 4.2.3(Nominal Dimensions-variation in the length of units ) |
- |
1000 |
|
- |
| 9.2 & 4.2.3(Nominal Dimensions -variation in height and width of units ) |
- |
1000 |
|
- |
| 9.2 & 4.2.4, Table-1(Nominal Dimensions-thickness of
the face shell) |
- |
1000 |
|
- |
| 9.2 & 4.2.4, Table-1(Nominal Dimensions-thickness of
the Web shell) |
- |
1000 |
|
- |
| 9.3 & 5.1 & 5.2 Table 2(PHYSICAL REQUIREMENTS-Blocks Density - 1.Hollow (Open and Closed Cavity) Concrete Block- Grade Aor Grade B 2.Solid Concrete Block — Grade C) |
- |
1000 |
|
- |
| 9.4- Table 2(PHYSICAL REQUIREMENTS - Compressive Strength 1.Minimum Average Compressive Strength of Units 2.Minimum Average Compressive Strength of Individual Unit) |
- |
4500 |
|
- |
| 9.5(PHYSICAL REQUIREMENTS -Water Absorption) |
- |
2000 |
|
- |
| 9.6(PHYSICAL REQUIREMENTS -Drying Shrinkage) |
- |
5500 |
|
- |
| 9.7(PHYSICAL REQUIREMENTS -Moisture Movement) |
- |
2500 |
|
- |
| 15(Marking) |
- |
500 |
|
- |
|
- |
- - |
| 11053 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 12894 (2002) |
Pulverized fuel ash - Lime bricks - Specification |
All Type |
7800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(General Requirements) |
- |
200 |
|
- |
| 3.2(General Requirements) |
- |
200 |
|
- |
| 3.3(General Requirements) |
- |
200 |
|
- |
| 3.4(General Requirements) |
- |
200 |
|
- |
| 3.5(General Requirements) |
- |
200 |
|
- |
| 5.1(Dimensions) |
- |
600 |
|
- |
| 7.1, Table -1(Average Wet Compressive Strength) |
- |
1500 |
|
- |
| 7.2(Drying Shrinkage) |
- |
3500 |
|
- |
| 7.3(Efflorescence Test) |
- |
1000 |
|
- |
| 7.4(Water Absorption) |
- |
1000 |
|
- |
| 5.2(Tolerance) |
- |
200 |
|
- |
| 9(Marking) |
- |
200 |
|
- |
|
- |
- - |
| 11054 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 12592 (2002) |
Precast concrete manhole cover and frame - Specification (First Revision) |
All Type |
13500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Grade) |
- |
500 |
|
- |
| 3(Type/Shape of Cover) |
- |
200 |
|
- |
| 4.4(Reinforcement) |
- |
200 |
|
- |
| 4.4(Reinforcement) |
- |
200 |
|
- |
| 4.5(Steel Fibres - Diameter / equivalent diameterofsteel tibres) |
- |
200 |
|
- |
| 4.5(Steel Fibres - The aspect ratio of the tibres) |
- |
1500 |
|
- |
| 5.2 and Table 1(Dimensions of Frame - A) |
- |
500 |
|
- |
| 5.2 and Table 1(Dimensions of Frame - B) |
- |
500 |
|
- |
| 5.2 and Table 1(Dimensions of Frame - C) |
- |
500 |
|
- |
| 5.2 and Table 1(Dimensions of Frame - D) |
- |
500 |
|
- |
| 5.2 and Table 1(Dimensions of Frame - E) |
- |
500 |
|
- |
| 5.2 and Table 1(Dimensions of Frame - F) |
- |
500 |
|
- |
| 5.2(Dimensions of cover- Diameter) |
- |
500 |
|
- |
| 5.2(Clearance at top between the frame and the cover all round the periphery) |
- |
500 |
|
- |
| 5.2(Top surface ofthe frame and cover is in level) |
- |
500 |
|
- |
| 5.2(Suitable taper matching with taper given for the frame shall be provided to the periphery of the cover) |
- |
500 |
|
- |
| 5.2 and Fig 1(Clear cover to reinforcement) |
- |
500 |
|
- |
| 5.2 and Fig 1(Distance of housing from the edge) |
- |
500 |
|
- |
| 7.4.1(Edge Protection and Finishing - Frame) |
- |
500 |
|
- |
| 7.4.2(Edge Protection and Finishing - Cover) |
- |
500 |
|
- |
| 8(LIFTING HOOKS) |
- |
500 |
|
- |
| 9.1(General) |
- |
500 |
|
- |
| 9.3 and Table and
Annex C(Load Test) |
- |
8000 |
|
- |
| Clause No. 5.2, Figure 1(Typical Illustration of circular precast concrete manhole cover) |
- |
500 |
|
- |
| Clause No. 9.3 Annex C(Adhesion between concrete and reinforcing steel) |
- |
500 |
|
- |
| Clause No. 9.3 Annex C(Cracks at bottom side of the cover ) |
- |
500 |
|
- |
| Clause No. 9.3 Annex C(Permanent set of cover) |
- |
500 |
|
- |
| Clause No. 9.3, 12.3 & C-1.1, Table No. 2(2/3rd of Test Load) |
- |
8000 |
|
- |
| Clause No. 9.3, 12.3 & C-1.1, Table No. 2(Test Load) |
- |
8000 |
|
- |
| Clause No. 8(Lifting Device) |
- |
500 |
|
- |
| Clause No. 8(Lifting Hooks (Diameter of MS rod)) |
- |
500 |
|
- |
| Clause No. 7.4.4(Compatitbilty of Seating of cover and frame) |
- |
500 |
|
- |
| Clause No. 7.4.2(Edge protection and finishing of cover (Thikness of MS sheet)) |
- |
500 |
|
- |
| Clause No. 7.4.2(Edge protection and finishing of cover (Cover finish of top surface)) |
- |
500 |
|
- |
| Clause No. 7.4.1(Edge protection and finishing of frame (Steel connectors)) |
- |
500 |
|
- |
| Clause No. 7.4.1(Edge protection and finishing of frame (Size of mild steel flat)) |
- |
500 |
|
- |
| Clause No. 6(Design) |
- |
0 |
|
- |
|
- |
- - |
| 11055 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 6603 (2001) |
Stainless steel bars and flats - Specification (First Revision) |
All type |
16300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Carbon -Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
300 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Silicon- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
300 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Manganese- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
300 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Nickel -Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
300 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Chromium- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
300 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Molybdenum- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
300 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Titanium- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
300 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Niobium- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
300 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Sulphur- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
300 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Phosphorus- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
300 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Others (Nitrogen)- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
300 |
|
- |
| Cl.14.1(Corrosion Resistance- IS 10461(Part1)) |
- |
2500 |
|
- |
| Cl.14.1(Corrosion Resistance- IS 10461(Part2)) |
- |
2500 |
|
- |
| 6(Freedom from defects:) |
- |
300 |
|
- |
| 9.1, Table 3(0.2 Percent Proof Stress, MPa) |
- |
1000 |
|
- |
| 9.2, Table 3(Tensile Strength, MPa) |
- |
1500 |
|
- |
| 9.3, Table 3(Elongation ,Percent) |
- |
1000 |
|
- |
| 9.4, Table 3(Annealed Hardness, HB-IS 1500: Pt 1) |
- |
1800 |
|
- |
| 9.5, Table 3(Charpy Impact Test, J-IS 1499) |
- |
1500 |
|
- |
| 12(Dimensions & Tolerances, mm-IS 6603) |
- |
200 |
|
- |
| 12(Diameter, mm) |
- |
200 |
|
- |
| 12(Out of Round , mm) |
- |
200 |
|
- |
| 12(Length , mm) |
- |
200 |
|
- |
| 12(Variation in Straightness) |
- |
300 |
|
- |
| Cl. 12
Table 9, 11 & 13 (Square Size) |
- |
300 |
|
- |
| Cl. 12
Table 11,13 & 14(Thickness of Flat) |
- |
200 |
|
- |
| Cl. 12
Table 11,13 & 14(Width of Flat) |
- |
200 |
|
- |
| Cl. 12
Table 10 & 13(Hexagonal Size) |
- |
200 |
|
- |
| Cl. 12
Table 9(Out of Square) |
- |
200 |
|
- |
| Cl. 12
Table 10(Maximum Differences in Three Measurements for Hexagons) |
- |
500 |
|
- |
| Cl. 9.3 Table 3(Bend Test) |
- |
700 |
|
- |
| 9.4(Annealed Hardness) |
- |
1500 |
|
- |
| Cl 9.1/Table-3(0.2% proof stress/Yield stress) |
- |
1000 |
|
- |
| Cl 9.1/Table-3(Tensile strength) |
- |
1500 |
|
- |
| Cl 9.1/Table-3(Elongation) |
- |
1000 |
|
- |
| 15(Marking) |
- |
200 |
|
- |
|
- |
- - |
| 11056 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 1489 : Part 2 (2015) |
Portland - Pozzolana cement - Specification: Part 2 calcined clay based |
All type |
10500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 - Table - 1 i(Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 ii(Magnesia - Cl 7.2 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 iv(Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 v(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 vi( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
600 |
|
- |
| 7 -Table 2- i(Fineness 4031 Part 2) |
- |
500 |
|
- |
| 7 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
500 |
|
- |
| 7 -Table 2- ii- a(Expansion after aeration - 4031 Part 3) |
- |
500 |
|
- |
| 7 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
500 |
|
- |
| 7 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
500 |
|
- |
| 7 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
500 |
|
- |
| 7 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
400 |
|
- |
| 7 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
600 |
|
- |
| 7 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
800 |
|
- |
| 7 -Table 2- v(Transverse Strength - IS 4031 Part 8 (Optional)) |
- |
1200 |
|
- |
| 7 -Table 2- vi(Drying Shrinkage- IS 4031 Part 10) |
- |
1500 |
|
- |
|
- |
- - |
| 11057 |
BIS, Central Laboratory (CL)
| None
| IS 15500 : Part 1 to 8 (2021) |
Deepwell Handpumps Components and Special Tools Specification |
- |
4500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Fig. 6.13 of IS 15500 : PART 6 (2021) (Check Valve Seat-VLOM 65) |
- |
|
|
|
| Fig. 6.12 of IS 15500 : PART 6 (2021) ("Check Valve Seat-Standard (for SDWP & EDWP)") |
- |
|
|
|
| Fig. 6.11 of IS 15500 : PART 6 (2021) ("Rubber Seat Retainer (for SDWP, EDWP & FLP)") |
- |
|
|
|
|
- |
- - |
| 11058 |
Central Institute of Petrochemicals Engineering & Technology (CIPET), CSTS - Dehradun
| 9178004
| IS 10124 : Part 2 (2009) |
Fabricated pvc - U fittings for potable water supplies - Specification: Part 2 specific requirements for sockets (Second Revision) |
- |
5550.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2.2, and Fig. 2(Dimensions of Socket for Elastomeric Sealing Ring Joint) |
- |
0.00 |
|
all dimension have Single Charge and for this dimension we have taken in below parameter. |
| 3.1(General) |
- |
5550.00 |
|
1.Socket length & Diameter at mid point of Socket Length- 500
2. Opacity-700
3. Short Term Hydrostatic pressure test- 850 500
4. Effect on water -3000
5. Dimension of Sockets - 0 |
| 10.3 of IS 4985 & Cl. 3.1 of IS 12235(P-4)(Effect on water: Lead (First Extraction)) |
- |
0.00 |
|
TEST CHARGE FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| 10.3 of IS 4985 & Cl. 3.1 of IS 12235(P-4)(Effect on water: Lead (Third Extraction)) |
- |
0.00 |
|
TEST CHARGE FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| 10.3 of IS 4985 & Cl. 3.1 of IS 12235(P-10)(Effect on water:Dialkyl tin C4 and
higher homologues
measured as tin (third
extraction)) |
- |
0.00 |
|
TEST CHARGE FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| 10.3 of IS 4985 & Cl. 3.2 of IS 12235(P-4)(Effect on water: Cadmium (all three extracts)) |
- |
0.00 |
|
TEST CHARGE FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| 10.3 of IS 4985 & Cl. 3.2 of IS 12235(P-4)(Effect on water: Mercury (all three extracts)) |
- |
0.00 |
|
TEST CHARGE FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| 10.3 of IS 4985 & Cl. 3.2 of IS 12235(P-10)(Other toxic substances such as 'di-n-octyl-tin- s-s bis iso-octyl mercapto acetate' and 'butyl stearate' (third extraction)) |
- |
0.00 |
|
TEST CHARGE FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| 10.7 of IS 4985(Sulphated Ash content, Annex-B of IS 4985) |
- |
0.00 |
|
TEST CHARGE FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| 3.2.1, Table-1, Fig-1(Nominal size) |
- |
0.00 |
|
TEST CHARGE FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| 3.2.1, Table-1, Fig-1(B) |
- |
0.00 |
|
TEST CHARGE FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| 3.2.1, Table-1, Fig-1(Minimum wall thickness for working pressure) |
- |
0.00 |
|
TEST CHARGE FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| 3.2.1, Table-1, Fig-1(Plumbing) |
- |
0.00 |
|
TEST CHARGE FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| Clause 3.2.2, and Fig. 2(Nominal size) |
- |
0.00 |
|
TEST CHARGE FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| Clause 3.2.2, and Fig. 2.(B) |
- |
0.00 |
|
TEST CHARGE FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| Clause 3.2.2, and Fig. 2.(Minimum wall thickness for working pressure) |
- |
0.00 |
|
TEST CHARGE FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
|
24 Apr, 2027 |
- VCM Content |
| 11059 |
IDMA LABORATORIES LIMITED, PANCHKULA
| 9123236
| IS 9532 (2023) |
CHAKKA AND SHRIKHAND - SPECIFICATION (First Revision of IS 9532) |
- |
10800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1.2(Appearance and colours- IS 9532-2023) |
- |
400 |
|
Testing charges Rs 10800/- for Shrikhand only
Testing charges Rs 10000/- for Chakka only |
| 6.1.3(Odour and Flavour- IS 9532-2023) |
- |
400 |
|
NA |
| 6.1.4(Texture and Consistency- IS 9532-2023) |
- |
400 |
|
NA |
| Table 1 clause 6.1.6 (i)(Total solids-IS 11622) |
- |
800 |
|
NA |
| Table 1 clause 6.1.6 (ii)(Milk fat (on drybasis)- IS 11762) |
- |
800 |
|
NA |
| Table 1 clause 6.1.6 (iii)(Milk protein (on dry basis)- IS 11917) |
- |
800 |
|
NA |
| Table 1 clause 6.1.6 (iv)(Titrable acidity (as lactic acid)- 12 Of IS 1479 Part 1) |
- |
800 |
|
NA |
| Table 1 clause 6.1.6 (v)(Total ash (on dry basis) -Annex C of IS 14433) |
- |
800 |
|
NA |
| 6.1.2(Appearance and colours- IS 9532-2023) |
- |
0 |
|
NA |
| 6.1.3(Odour and Flavour- IS 9532-2023) |
- |
0 |
|
NA |
| 6.1.4(Texture and Consistency- IS 9532-2023) |
- |
0 |
|
NA |
| Table 1 clause 6.1.6 (i)(Total solids-IS 11622) |
- |
0 |
|
NA |
| Table 1 clause 6.1.6 (ii)(Milk fat (on drybasis)- IS 11762) |
- |
0 |
|
NA |
| Table 1 clause 6.1.6 (iii)(Milk protein (on dry basis)- IS 11917) |
- |
0 |
|
NA |
| Table 1 clause 6.1.6 (iv)(Titrable acidity (as lactic acid)- 12 Of IS 1479 Part 1) |
- |
0 |
|
NA |
| Table 1 clause 6.1.6 (v)(Total ash (on dry basis) -Annex C of IS 14433) |
- |
0 |
|
NA |
| Table 2 clause 6.1.6 & 6.2.6 (i)(Coliform count) |
- |
800 |
|
NA |
| Table 2 clause 6.1.6 & 6.2.6 (ii)(Staphylococcus aureus(Coagulase positive)) |
- |
800 |
|
NA |
| Table 2 clause 6.1.6 & 6.2.6 (iii)(Yeast & Mould count) |
- |
800 |
|
NA |
| Table 2 clause 6.1.6 & 6.2.6 (iv)(E.coli) |
- |
800 |
|
NA |
| Table 2 clause 6.1.6 & 6.2.6 (v)(Salmonella sp.) |
- |
800 |
|
NA |
| Table 2 clause 6.1.6 & 6.2.6 (vi)(Listeria monocytogenes
/g) |
- |
800 |
|
NA |
| 6.1.2(Appearance and colours- IS 9532-2023) |
- |
0 |
|
NA |
| 6.1.3(Odour and Flavour- IS 9532-2023) |
- |
0 |
|
NA |
| 6.1.4(Texture and Consistency- IS 9532-2023) |
- |
0 |
|
NA |
| Table 1 clause 6.1.6 (i)(Total solids-IS 11622) |
- |
0 |
|
NA |
| Table 1 clause 6.1.6 (ii)(Milk fat (on drybasis)- IS 11762) |
- |
0 |
|
NA |
| Table 1 clause 6.1.6 (iii)(Milk protein (on dry basis)- IS 11917) |
- |
0 |
|
NA |
| Table 1 clause 6.1.6 (iv)(Titrable acidity (as lactic acid)- 12 Of IS 1479 Part 1) |
- |
0 |
|
NA |
| Table 1 clause 6.1.6 (v)(Total ash (on dry basis) -Annex C of IS 14433) |
- |
0 |
|
NA |
| Table 2 clause 6.1.6 & 6.2.6 (i)(Coliform count) |
- |
0 |
|
NA |
| Table 2 clause 6.1.6 & 6.2.6 (ii)(Staphylococcus aureus(Coagulase positive)) |
- |
0 |
|
NA |
| Table 2 clause 6.1.6 & 6.2.6 (iii)(Yeast & Mould count) |
- |
0 |
|
NA |
| Table 2 clause 6.1.6 & 6.2.6 (iv)(E.coli) |
- |
0 |
|
NA |
| Table 2 clause 6.1.6 & 6.2.6 (v)(Salmonella sp.) |
- |
0 |
|
NA |
| Table 2 clause 6.1.6 & 6.2.6 (vi)(Listeria monocytogenes
/g) |
- |
0 |
|
NA |
| 6.1.2(Appearance and colours- IS 9532-2023) |
- |
0 |
|
- |
| 6.1.3(Odour and Flavour- IS 9532-2023) |
- |
0 |
|
- |
| 6.1.4(Texture and Consistency- IS 9532-2023) |
- |
0 |
|
- |
| Table 1 clause 6.1.6 (i)(Total solids-IS 11622) |
- |
0 |
|
- |
| Table 1 clause 6.1.6 (ii)(Milk fat (on drybasis)- IS 11762) |
- |
0 |
|
- |
| Table 1 clause 6.1.6 (iii)(Milk protein (on dry basis)- IS 11917) |
- |
0 |
|
- |
| Table 1 clause 6.1.6 (iv)(Titrable acidity (as lactic acid)- 12 Of IS 1479 Part 1) |
- |
0 |
|
- |
| Table 1 clause 6.1.6 (v)(Total ash (on dry basis) -Annex C of IS 14433) |
- |
0 |
|
- |
| Table 2 clause 6.1.6 & 6.2.6 (i)(Coliform count) |
- |
0 |
|
- |
| Table 2 clause 6.1.6 & 6.2.6 (ii)(Staphylococcus aureus(Coagulase positive)) |
- |
0 |
|
- |
| Table 2 clause 6.1.6 & 6.2.6 (iii)(Yeast & Mould count) |
- |
0 |
|
- |
| Table 2 clause 6.1.6 & 6.2.6 (iv)(E.coli) |
- |
0 |
|
- |
| Table 2 clause 6.1.6 & 6.2.6 (v)(Salmonella sp.) |
- |
0 |
|
- |
| Table 2 clause 6.1.6 & 6.2.6 (vi)(Listeria monocytogenes
/g) |
- |
0 |
|
- |
| 6.1.2(Appearance and colours- IS 9532-2023) |
- |
0 |
|
- |
| 6.1.3(Odour and Flavour- IS 9532-2023) |
- |
0 |
|
- |
| 6.1.4(Texture and Consistency- IS 9532-2023) |
- |
0 |
|
- |
| Table 1 clause 6.1.6 (i)(Total solids-IS 11622) |
- |
0 |
|
- |
| Table 1 clause 6.1.6 (ii)(Milk fat (on drybasis)- IS 11762) |
- |
0 |
|
- |
| Table 1 clause 6.1.6 (iii)(Milk protein (on dry basis)- IS 11917) |
- |
0 |
|
- |
| Table 1 clause 6.1.6 (iv)(Titrable acidity (as lactic acid)- 12 Of IS 1479 Part 1) |
- |
0 |
|
- |
| Table 1 clause 6.1.6 (v)(Total ash (on dry basis) -Annex C of IS 14433) |
- |
0 |
|
- |
| Table 2 clause 6.1.6 & 6.2.6 (i)(Coliform count) |
- |
0 |
|
- |
| Table 2 clause 6.1.6 & 6.2.6 (ii)(Staphylococcus aureus(Coagulase positive)) |
- |
0 |
|
- |
| Table 2 clause 6.1.6 & 6.2.6 (iii)(Yeast & Mould count) |
- |
0 |
|
- |
| Table 2 clause 6.1.6 & 6.2.6 (iv)(E.coli) |
- |
0 |
|
- |
| Table 2 clause 6.1.6 & 6.2.6 (v)(Salmonella sp.) |
- |
0 |
|
- |
| Table 2 clause 6.1.6 & 6.2.6 (vi)(Listeria monocytogenes
/g) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f 06.09.2024 |
| 11060 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 2202 : Part 1 (1999) |
Wooden flush door shutters (Solid Core Type) - Specification: Part 1 plywood face panels (Sixth Revision) |
All type |
20500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 11.15(Screw Withdrawal Strength - IS 4020 (Pt-16)) |
- |
1000 |
|
- |
| 11.15(Screw Withdrawal Resistance test - IS 4020 (Pt-16)) |
- |
1000 |
|
- |
| 11.14(Glue Adhesion Test - IS 4020(Pt-15)) |
- |
1200 |
|
- |
| 11.13(Knife Test - IS 4020(Pt-14)) |
- |
1000 |
|
- |
| 11.12(End Immersion Test - IS 4020(Pt-13)) |
- |
1500 |
|
- |
| 11.11(The recovery of the original size after subjecting the door to high and low humidity- IS 4020(Pt-12)) |
- |
2000 |
|
- |
| 11.11(Maximum departure from the general planeness - IS 4020(Pt-12)) |
- |
2000 |
|
- |
| 11.11(Varying Humidity Test - IS 4020(Pt-12)) |
- |
2000 |
|
- |
| 11.1(Misuse Test - IS 4020(Pt-11)) |
- |
2500 |
|
- |
| 11.9(Slamming Test - IS 4020(Pt-10)) |
- |
1500 |
|
- |
| 11.8(Residual deformation after 15 minutes of unloading - IS 4020(Pt-9)) |
- |
1000 |
|
- |
| 11.8(Initial deflection - IS 4020(Pt-9)) |
- |
1000 |
|
- |
| 11.8(Buckling Test - IS 4020(Pt-9)) |
- |
1000 |
|
- |
| 11.7(Shock Resistance Test -IS 4020(Pt-8)) |
- |
2000 |
|
- |
| 11.7(Shock Resistance Test -IS 4020(Pt-8)) |
- |
2000 |
|
- |
| 11.6(Residual lateral buckling - IS 4020(Pt-7)) |
- |
750 |
|
- |
| 11.6(Lateral buckling during loading - IS 4020(Pt-7)) |
- |
750 |
|
- |
| 11.6(Residual deflection after removal of load - IS 4020(Pt-7)) |
- |
750 |
|
- |
| 11.6(Deflection of the edge at maximum load - IS 4020(Pt-7)) |
- |
750 |
|
- |
| 11.5(Residual deflection - IS 4020(Pt-6)) |
- |
1250 |
|
- |
| 11.4(Depth of indentation - IS 4020(Pt-5)) |
- |
1250 |
|
- |
| 11.4(Impact Indentation Test - IS 4020(Pt-5)) |
- |
1250 |
|
- |
| 11.3(Depth of deviation - IS 4020(Pt-4)) |
- |
400 |
|
- |
| 11.2( Twist, cupping & wrapping - IS 4020 (Pt-3)) |
- |
400 |
|
- |
| 11.1( Squareness Test - IS 4020 (Pt-2)) |
- |
300 |
|
- |
| 11.1(Variation in thickness - IS 4020 (Pt-2)) |
- |
200 |
|
- |
| 11.1(Thickness - IS 4020 (Pt-2)) |
- |
200 |
|
- |
| 11.1(Width- IS 4020 (Pt-2)) |
- |
200 |
|
- |
| 11.1(Height - IS 4020 (Pt-2)) |
- |
200 |
|
- |
| 9.3(Workmanship & finish - IS 2202(Pt-1)) |
- |
200 |
|
- |
| 9.2(Workmanship & finish - IS 2202(Pt-1)) |
- |
200 |
|
- |
| 6.2(Plywood) |
- |
0 |
|
- |
| 6.3(Cross-Band) |
- |
0 |
|
- |
| 6.4(Cross-Bands) |
- |
0 |
|
- |
| 6.7(Particle Board) |
- |
0 |
|
- |
| 6.8(Medium Density Fibre
(MDF) Board) |
- |
0 |
|
- |
|
- |
- - |
| 11061 |
IDMA LABORATORIES LIMITED, PANCHKULA
| 9123236
| IS 12361 (2023) |
Partially Hydrogenated Rice Bran Fatty Acids - Specification (first revision of IS 12361) |
- |
13500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2(Description) |
- |
1000 |
|
- |
| 3.3 Table 1 (i)(Moisture) |
- |
1000 |
|
- |
| 3.3 Table 1 (ii)(Saponification value) |
- |
1500 |
|
- |
| 3.3 Table 1 (iii)(Acid value shall not differfrom saponification value) |
- |
1500 |
|
- |
| 3.3 Table 1 (iv)(Iodine Value) |
- |
1500 |
|
- |
| 3.3 Table 1 (v)(Mineral Acidity) |
- |
1500 |
|
- |
| 3.3 Table 1 (vi)(Ash) |
- |
1000 |
|
- |
| 3.3 Table 1 (vii)(Unsaponifiable matter) |
- |
1500 |
|
- |
| 3.3 Table 1 (viii)(Titre) |
- |
1500 |
|
- |
| 3.3 Table 1 (ix)(Colour in a 1-in cell on the Lovibond scale expressed as Y + 5R) |
- |
1500 |
|
- |
| 3.2(Description) |
- |
0 |
|
NA |
| 3.3 Table 1 (i)(Moisture) |
- |
0 |
|
- |
| 3.3 Table 1 (ii)(Saponification value) |
- |
0 |
|
- |
| 3.3 Table 1 (iii)(Acid value shall not differfrom saponification value) |
- |
0 |
|
- |
| 3.3 Table 1 (iv)(Iodine Value) |
- |
0 |
|
- |
| 3.3 Table 1 (v)(Mineral Acidity) |
- |
0 |
|
- |
| 3.3 Table 1 (vi)(Ash) |
- |
0 |
|
- |
| 3.3 Table 1 (vii)(Unsaponifiable matter) |
- |
0 |
|
- |
| 3.3 Table 1 (viii)(Titre) |
- |
0 |
|
- |
| 3.3 Table 1 (ix)(Colour in a 1-in cell on the Lovibond scale expressed as Y + 5R) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f 06.09.2024 |
| 11062 |
IDMA LABORATORIES LIMITED, PANCHKULA
| 9123236
| IS 6444 (2023) |
Sulphur Dusting Powders - Specification second revision |
- |
4500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Description - IS 6444:2023) |
- |
500 |
|
- |
| 3.2.1 & 3.2 Table 1 (i)(Sulphr Content - IS 6444:2023) |
- |
2000 |
|
- |
| 3.2 Table 1 (ii)(Material passing through 75 micron IS Sieve - IS 6940:1982) |
- |
1000 |
|
- |
| 3.2 Table 1 (iii)(Bulk Density after compacting - IS 6940:1982) |
- |
1000 |
|
- |
| 3.1(Description - IS 6444:2023) |
- |
0 |
|
- |
| 3.2.1 & 3.2 Table 1 (i)(Sulphr Content - IS 6444:2023) |
- |
0 |
|
- |
| 3.2 Table 1 (ii)(Material passing through 75 micron IS Sieve - IS 6940:1982) |
- |
0 |
|
- |
| 3.2 Table 1 (iii)(Bulk Density after compacting - IS 6940:1982) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f 06.09.2024 |
| 11063 |
Central Institute of Petrochemicals Engineering & Technology (CIPET), CSTS - Dehradun
| 9178004
| IS 7834 : Part 4 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 4 Specific requirements for 90 degree tees |
16 to 315 mm |
5750.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.1(General) |
- |
5750.00 |
|
Dimensions- 500.00
Stress Relief test- 700.00
Opacity- 700.00
Effect on water test- 3000.00
Short term Hydraulic test (27 °C/1hour.)- 850.00 |
| 2.2.2 table 1(Laying length) |
- |
0.00 |
|
All dimensions have single charge and this parameter charge is already covered in General testing. |
| 2.2.3( inside diameter of the socket) |
- |
0.00 |
|
All dimensions have single charge and this parameter charge is already covered in General testing. |
| table 1 sl.no: 01(16
) |
- |
0.00 |
|
- |
| table 1 sl.no: 02(20
) |
- |
0.00 |
|
- |
| table 1 sl.no: 03(25
) |
- |
0.00 |
|
- |
| table 1 sl.no: 04(32
) |
- |
0.00 |
|
- |
| table 1 sl.no: 05(40
) |
- |
0.00 |
|
- |
| table 1 sl.no: 06(50
) |
- |
0.00 |
|
- |
| table 1 sl.no: 07(63
) |
- |
0.00 |
|
- |
| table 1 sl.no: 08(75
) |
- |
0.00 |
|
- |
| table 1 sl.no: 09(90
) |
- |
0.00 |
|
- |
| table 1 sl.no: 10(110
) |
- |
0.00 |
|
- |
| table 1 sl.no: 11(125
) |
- |
0.00 |
|
- |
| table 1 sl.no: 12(140
) |
- |
0.00 |
|
- |
| table 1 sl.no: 13(160
) |
- |
0.00 |
|
- |
| table 1 sl.no: 14(
180
) |
- |
0.00 |
|
- |
| table 1 sl.no: 15(200
) |
- |
0.00 |
|
- |
| table 1 sl.no: 16(225
) |
- |
0.00 |
|
- |
| table 1 sl.no: 17(250.0) |
- |
0.00 |
|
- |
| table 1 sl.no: 18(280.0) |
- |
0.00 |
|
- |
| table 1 sl.no: 19(315.0) |
- |
0.00 |
|
- |
| 2.2(Manufacture) |
- |
0.00 |
|
TEST CHARGES FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| 2.2.2, Table 1(Size) |
- |
0.00 |
|
TEST CHARGES FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| 2.2.2, Table 1(90 ̊ Elbow Laying
Length) |
- |
0.00 |
|
TEST CHARGES FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| 2.2.3( inside diameter of the socket) |
- |
0.00 |
|
TEST CHARGES FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| 2.2.3(Socket length) |
- |
0.00 |
|
TEST CHARGES FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| 2.2(Manufacture) |
- |
0.00 |
|
TEST CHARGES FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| 2.2.2, Table 1(Size) |
- |
0.00 |
|
TEST CHARGES FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| 2.2.2, Table 1(90 ̊ Elbow Laying
Length) |
- |
0.00 |
|
TEST CHARGES FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| 2.2.3(Socket length) |
- |
0.00 |
|
TEST CHARGES FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
| 2.1(General) |
- |
0.00 |
|
TEST CHARGES FOR THIS PARAMETER ALREADY TAKEN ABOVE. |
|
24 Apr, 2027 |
- Exclusion: Cl 6.1.1 (VCM Content Test) |
| 11064 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 3854 (2023) |
Switches for Domestic and Similar Purposes - Specification (Third Revision) |
- |
Check test charges remarks View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4 (General Requirements) |
- |
|
|
|
|
- |
- Excluding Making & Breaking & Normal operation test apparatus, Switches Intended for Externally |
| 11065 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 1239 : Part 2 (2011) |
Steel tubes, tubulars and other steel fittings - Specification: Part 2 steel pipe fittings (Fifth Revision) |
All Type |
12500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Chemical Composition - Sulphur - Laddle Analysis IS 228) |
- |
300 |
|
- |
| 7.1(Chemical Composition - Phosphorus - Laddle Analysis IS 228) |
- |
300 |
|
- |
| 8.1-Table 1( DIMENSIONS OF TUBULARS-Pieces
) |
- |
400 |
|
- |
| 8.1-Table 1( DIMENSIONS OF TUBULARS-Pieces-Approximate Standard Length(A)
) |
- |
400 |
|
- |
| 8.2-Table-2( DIMENSIONS OF TUBULARS-Nipples
) |
- |
400 |
|
- |
| 8.2-Table-2( DIMENSIONS OF TUBULARS-Nipples-A
) |
- |
400 |
|
- |
| 8.2-Table-2( DIMENSIONS OF TUBULARS-Nipples-B
) |
- |
400 |
|
- |
| 8.2-Table-2( DIMENSIONS OF TUBULARS-Nipples-C
) |
- |
400 |
|
- |
| 8.3.1-Table 3(DIMENSIONS OF TUBULARS-Longscrews (Connectors)) |
- |
400 |
|
- |
| 8.3.1-Table 3(DIMENSIONS OF TUBULARS-Longscrews (Connectors)-A) |
- |
400 |
|
- |
| 8.3.1-Table 3(DIMENSIONS OF TUBULARS-Longscrews (Connectors)-B) |
- |
400 |
|
- |
| 8.3.1-Table 3(DIMENSIONS OF TUBULARS-Longscrews (Connectors)-C) |
- |
400 |
|
- |
| 8.3.2(DIMENSIONS OF TUBULARS-Longscrews (Connectors)) |
- |
400 |
|
- |
| 8.3.2(DIMENSIONS OF TUBULARS-Longscrews (Connectors)-The face of the back nut angle) |
- |
400 |
|
- |
| 8.4.1 -Table 4(Bends and springs) |
- |
1000 |
|
- |
| 8.4.1 -Table 4(Bends and springs-A) |
- |
1000 |
|
- |
| 8.4.1 -Table 4(Bends and springs-B) |
- |
1000 |
|
- |
| 8.4.1 -Table 4(Bends and springs-R) |
- |
1000 |
|
- |
| 8.4.1 -Table 4(Bends and springs-C) |
- |
1000 |
|
- |
| 8.4.1 -Table 4(Bends and springs-E) |
- |
1000 |
|
- |
| 8.5-Table 5( Return Bends) |
- |
1000 |
|
- |
| 8.5-Table 5( Return Bends-A) |
- |
1000 |
|
- |
| 8.5-Table 5( Return Bends-B) |
- |
1000 |
|
- |
| 8.6 -Table 6(Sockets) |
- |
500 |
|
- |
| 8.6 -Table 6(Sockets-A) |
- |
500 |
|
- |
| 8.6 -Table 6(Sockets-B) |
- |
500 |
|
- |
| 8.6 -Table 6(Maximum Inside Diameter of Internal Parallel Thread) |
- |
500 |
|
- |
| 9(DIMENSIONS OF STEEL FITTINGS (OTHER THAN TUBULARS)) |
- |
500 |
|
- |
| 9.1-Table 7(Dimensions of Screwed Ends of Fittings-D
) |
- |
500 |
|
- |
| 9.1-Table 7(Dimensions of Screwed Ends of Fittings-E
) |
- |
500 |
|
- |
| 9.1-Table 7(Dimensions of Screwed Ends of Fittings-d
) |
- |
500 |
|
- |
| 9.1-Table 7(Dimensions of Screwed Ends of Fittings-Taper
) |
- |
500 |
|
- |
| 9.1-Table 8 (Dimensions of Elbows, Tees and Crosses, Equal-A) |
- |
500 |
|
- |
| 9.1-Table 9 (Dimensions of Elbows Reducing-A) |
- |
500 |
|
- |
| 9.1-Table 9 (Dimensions of Elbows Reducing-B) |
- |
500 |
|
- |
| 9.1-Table 10 (Dimensions of Tees, Reducing (on the Branch)-A) |
- |
500 |
|
- |
| 9.1-Table 10 (Dimensions of Tees, Reducing (on the Branch)-B) |
- |
500 |
|
- |
| 9.1-Table 11 (Dimensions of Tees, Reducing (on the Run and Branch, or on the Run Only)-A) |
- |
500 |
|
- |
| 9.1-Table 11 (Dimensions of Tees, Reducing (on the Run and Branch, or on the Run Only)-B) |
- |
500 |
|
- |
| 9.1-Table 12(Dimensions of Tees (Increasing on the Branch)-A) |
- |
500 |
|
- |
| 9.1-Table 12(Dimensions of Tees (Increasing on the Branch)-B) |
- |
500 |
|
- |
| 9.1-Table 13( Dimensions of Crosses, Reducing-A) |
- |
500 |
|
- |
| 9.1-Table 13( Dimensions of Crosses, Reducing-B) |
- |
500 |
|
- |
| 9.1-Table 14( Elbows, Tees and Crosses, Side Outlet, Equal-A) |
- |
500 |
|
- |
| 9.1-Table 14( Elbows, Tees and Crosses, Side Outlet, Equal-B) |
- |
500 |
|
- |
| 9.1-Table 15( Dimensions of Elbows, Round, Male and Female, Equal-A) |
- |
500 |
|
- |
| 9.1-Table 15( Dimensions of Elbows, Round, Male and Female, Equal-B) |
- |
500 |
|
- |
| 9.1-Table 15( Dimensions of Elbows, Round, Male and Female, Equal-Minimum Bore of Male End) |
- |
500 |
|
- |
| 9.1-Table 15( Dimensions of Elbows, Round, Male and Female, Equal-Maximum Bore of Male End) |
- |
500 |
|
- |
| 9.1-Table 16( Dimensions of Elbows, Equal, 135°-A) |
- |
500 |
|
- |
| 9.1-Table 17 (Dimensions of Y-Pieces, Female, Equal-A) |
- |
500 |
|
- |
| 9.1-Table 18 (Dimensions of Socket, Reducing-A) |
- |
500 |
|
- |
| 9.1-Table 19 (Dimensions of Caps-A) |
- |
500 |
|
- |
| 9.1-Table 19 (Dimensions of Caps-T) |
- |
500 |
|
- |
| 9.1-Table 20(Dimensions of Plug-Minimum Length of Thread for Basic Gauge) |
- |
500 |
|
- |
| 9.1-Table 20(Dimensions of Plug-Minimum Length of Thread for Basic Gauge-S) |
- |
500 |
|
- |
| 9.1-Table 20(Dimensions of Plug-Minimum Length of Thread for Basic Gauge-H) |
- |
500 |
|
- |
| 9.1-Table 20(Dimensions of Plug-Minimum Length of Thread for Basic Gauge-D) |
- |
500 |
|
- |
| 9.1-Table 20(Dimensions of Plug-Minimum Length of Thread for Basic Gauge-K) |
- |
500 |
|
- |
| 9.1-Table 21 (Dimensions of Elbows, Tees and Crosses, Male, Equal-A) |
- |
500 |
|
- |
| 9.1-Table 22(Dimensions of Y-Pieces and Angle Tees, Male, Equal-A
) |
- |
500 |
|
- |
| 9.1-Table 22(Dimensions of Y-Pieces and Angle Tees, Male, Equal-B
) |
- |
500 |
|
- |
| 9.1-Table 23( Dimensions of Twin Elbows and Sweep Tees, Male, Equal-A) |
- |
500 |
|
- |
| 9.1-Table 23( Dimensions of Twin Elbows and Sweep Tees, Male, Equal-B) |
- |
500 |
|
- |
| 9.1-Table 24(Dimensions of Socket Unions-A
) |
- |
500 |
|
- |
| 9.1-Table 25 (Dimensions of Pipe Unions-A) |
- |
500 |
|
- |
| 9.1-Table 26 (Dimensions of Union Bends-A
) |
- |
500 |
|
- |
| 9.1-Table 27 (Dimensions of Hexagon Bushes-L) |
- |
500 |
|
- |
| 9.1-Table 27 (Dimensions of Hexagon Bushes-T) |
- |
500 |
|
- |
| 9.1-Table 27 (Dimensions of Hexagon Bushes-A) |
- |
500 |
|
- |
| 9.1-Table 27 (Dimensions of Hexagon Bushes-B) |
- |
500 |
|
- |
| 9.1-Table 28 (Dimensions of Nipples, Hexagon, Equal-L) |
- |
500 |
|
- |
| 9.1-Table 28 (Dimensions of Nipples, Hexagon, Equal-T) |
- |
500 |
|
- |
| 9.1-Table 28 (Dimensions of Nipples, Hexagon, Equal-C) |
- |
500 |
|
- |
| 9.1-Table 28 (Dimensions of Nipples, Hexagon, Equal-B) |
- |
500 |
|
- |
| 11.1(a)(Internal hydraulic Pressure Test) |
- |
2500 |
|
- |
| 11.1(a)(Internal Air Pressure Test) |
- |
2500 |
|
- |
| 14(WORKMANSHIP) |
- |
500 |
|
- |
| 13 and as per IS 4736(UNIFORMITY OF ZINC COATING) |
- |
1500 |
|
- |
| 13 and as per IS 4736(MASS OF ZINC COATING) |
- |
1500 |
|
- |
| Clause 13.1.3 (Adhesion Test) |
- |
2000 |
|
- |
| Clause 10(Joints ) |
- |
1000 |
|
- |
| Clause 9.2.3 (Threads tolerance ) |
- |
500 |
|
- |
| Clause 9.1, Table- 27(Normal Size (Internal Threads) (Dimensions of Hexagon Bushes) ) |
- |
500 |
|
- |
| Clause 9.1, Table- 27(Normal Size (External Threads) (Dimensions of Hexagon Bushes) ) |
- |
500 |
|
- |
| Clause 8.3.3(Parallel threads ) |
- |
500 |
|
- |
| Clause 9.2.2 (Tolerance for alignment of threads ) |
- |
500 |
|
- |
| 14(WORKMANSHIP) |
- |
500 |
|
- |
| 14(WORKMANSHIP) |
- |
500 |
|
- |
| 11.2.2 (Taper Screw Plug Test) |
- |
500 |
|
- |
| 11.2.1( Drift Expanding Test) |
- |
500 |
|
- |
| 9.1-Table 28 (Dimensions of Nipples, Hexagon, Equal-A) |
- |
500 |
|
- |
| 9.1-Table 26 (Dimensions of Union Bends-B
) |
- |
500 |
|
- |
| 8.4.1 -Table 4(Bends and springs-D) |
- |
1000 |
|
For BIS samples: 1.5 times of BIS testing charges (10% discount to BIS) |
|
- |
- - |
| 11066 |
IRCLASS Systems And Solutions Private Limited, Jaipur
| 8179206
| IS 10500 (2012) |
Drinking water - Specification (Second Revision) |
- |
13850 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| TABLE 6 sl no 1(All water intended for drinking:
a) E. coli or thermotolerant coliform bacteri) |
- |
1000 |
|
NA |
| TABLE 6 sl no 5(b) Total coliform bacteria) |
- |
1000 |
|
NA |
| TABLE 5 sl no 1(Alachlor) |
- |
120 |
|
NA |
| TABLE 5 sl no 2(Atrazine) |
- |
120 |
|
NA |
| TABLE 5 sl no 4( Alpha HCH) |
- |
120 |
|
NA |
| TABLE 5 sl no 5(Beta HCH) |
- |
120 |
|
NA |
| TABLE 5 sl no 6(Butachlor) |
- |
120 |
|
NA |
| TABLE 5 sl no 7(Chlorpyriphos) |
- |
120 |
|
NA |
| TABLE 5 sl no 8(Delta HCH) |
- |
120 |
|
NA |
| TABLE 5 sl no 9(2,4- Dichlorophenoxyacetic acid) |
- |
120 |
|
NA |
| TABLE 5 sl no 10( DDT (o, p and p, p – Isomers of DDT, DDE and DDD)) |
- |
120 |
|
NA |
| TABLE 5 sl no 11(Endosulfan (alpha, beta, and sulphate)) |
- |
120 |
|
NA |
| TABLE 5 sl no 12( Ethion) |
- |
120 |
|
NA |
| TABLE 5 sl no 13(Gamma — HCH (Lindane)) |
- |
120 |
|
NA |
| TABLE 5 sl no 14( Isoproturon) |
- |
120 |
|
NA |
| TABLE 5 sl no 15(Malathion) |
- |
120 |
|
NA |
| TABLE 5 sl no 16(Methyl parathion) |
- |
120 |
|
NA |
| TABLE 5 sl no 17(Monocrotophos) |
- |
120 |
|
NA |
| TABLE 5 sl no 18(Phorate) |
- |
120 |
|
NA |
| TABLE 3 sl no 1(Cadmium (as Cd), mg/l, Max) |
- |
240 |
|
NA |
| TABLE 3 sl no 2(Cyanide (as CN), mg/l, Max) |
- |
600 |
|
NA |
| TABLE 3 sl no 4(Mercury (as Hg), mg/l, Max) |
- |
240 |
|
NA |
| TABLE 3 sl no 5( Molybdenum (as Mo), mg/l, Max) |
- |
240 |
|
NA |
| TABLE 3 sl no 6(Nickel (as Ni), mg/l, Max) |
- |
240 |
|
NA |
| TABLE 3 sl no 8(Polychlorinated biphenyls, mg/l,) |
- |
600 |
|
NA |
| TABLE 3 sl no 9(Polynuclear aromatic hydro-carbons (as PAH), mg/l, Max) |
- |
600 |
|
NA |
| TABLE 3 sl no 10(Total arsenic (as As), mg/l, Max) |
- |
240 |
|
NA |
| TABLE 3 sl no 11(Total chromium (as Cr), mg/l, Max) |
- |
240 |
|
NA |
| TABLE 3 sl no 12(Bromoform, mg/l, Max) |
- |
120 |
|
NA |
| TABLE 3 sl no 13(Dibromochloromethane,) |
- |
120 |
|
NA |
| Table 3 (Clause 4)xii) Trihalomethanes: (b)(Bromodichloromethane) |
- |
120 |
|
NA |
| 4, Table (3), (xii), (d)(Chloroform, mg/l, Max) |
- |
120 |
|
NA |
| table 2 sl.no 1( Aluminium (as Al), mg/l, Max) |
- |
240 |
|
NA |
| table 2 sl.no 2(Ammonia (as total ammonia-N),
mg/l, Max) |
- |
240 |
|
NA |
| table 2 sl.no 3(Anionic detergents (as MBAS), mg/l, Max) |
- |
240 |
|
NA |
| table 2 sl.no 4(Barium (as Ba), mg/l, Max) |
- |
240 |
|
NA |
| table 2 sl.no 5(Boron (as B), mg/l, Max) |
- |
240 |
|
NA |
| table 2 sl.no 6(Calcium (as Ca), mg/l, Max) |
- |
240 |
|
NA |
| table 2 sl.no 9(Copper (as Cu), mg/l, Max) |
- |
240 |
|
NA |
| table 2 sl.no 10( Fluoride (as F) mg/l, Max) |
- |
240 |
|
NA |
| table 2 sl.no 11(Free residual chlorine, mg/l, Min) |
- |
240 |
|
NA |
| 4, Table (2), (vii)(Chloramines (as Cl2 ), mg/l, Max) |
- |
240 |
|
NA |
| 4, Table 2, Sr.no. viii(Chloride) |
- |
140 |
|
NA |
| table 2 sl.no 12(Iron (as Fe), mg/l, Max) |
- |
240 |
|
NA |
| table 2 sl.no 13(Magnesium (as Mg), mg/l, Max) |
- |
240 |
|
NA |
| table 2 sl.no 14(Manganese (as Mn), mg/l, Max) |
- |
240 |
|
NA |
| table 2 sl.no 16(Nitrate (as NO3), mg/l, Max) |
- |
240 |
|
NA |
| 4, Table (2), (xv)(Mineral oil, mg/l, Max) |
- |
240 |
|
NA |
| table 2 sl.no 17(Phenolic compounds (as C6H5OH), mg/l, Max) |
- |
240 |
|
NA |
| 4, Table (2), (xviii)(Selenium (as Se), mg/l, Max) |
- |
240 |
|
NA |
| 4, Table (2), (xix)(Silver (as Ag), mg/l, Max) |
- |
240 |
|
NA |
| table 2 sl.no 24(Zinc (as Zn), mg/l, Max) |
- |
240 |
|
NA |
| 4, Table (2), (xx)(Sulphate (as SO4 ) mg/l, Max) |
- |
120 |
|
NA |
| 4, Table (2), (xxi)(Sulphide (as H2 S), mg/l, Max) |
- |
180 |
|
NA |
| 4, Table (2), (xxii)(Total alkalinity as calcium
carbonate, mg/l, Max) |
- |
120 |
|
NA |
| 4, Table (2), (xxiii)(Total hardness (as CaCO3 ),
mg/l, Max) |
- |
480 |
|
NA |
| 4. SL No.i)of
Table I(Colour) |
- |
50 |
|
NA |
| 4.SL No.ii) of
Table I(Odour) |
- |
50 |
|
NA |
| 4.SL No.iii)of
Table I(pH) |
- |
120 |
|
NA |
| 4 ,Table (1), (iv)(Taste) |
- |
50 |
|
NA |
| 4.SL No.v)of
Table I(Turbidity, NTU, Max) |
- |
120 |
|
NA |
| 4.SL No.vi)of
Table I(Total dissolved solids, mg/l, max) |
- |
240 |
|
NA |
|
06 Aug, 2027 |
- Exclusion: 4.2 (Virological Requirements)
4, Table (4), (i), (a) (Alpha emitters Bq/l, Max)
4, table 4, i, b) (Beta emitters)
4.3 (Biological Requirements) |
| 11067 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 6912 (2005) |
Copper and copper alloys forging stock and forging - Specification (Second Revision) |
All Type |
6800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. No.4(SUPPLY OF MATERIAL) |
- |
0 |
|
- |
| Cl. No.6(Freedom from defects) |
- |
500 |
|
- |
| Cl. No.7, Table no. 1("DIMENSIONS AND TOLERANCES
") |
- |
600 |
|
- |
| Cl. No.8.1, Table no.2(i)(Electrolytic tough pitch through copper) |
- |
5100 |
|
- |
| Cl. No.8.1, Table no.2(ii)(Fire refined high conductivity copper) |
- |
5100 |
|
- |
| Cl. No.8.1, Table no.2(iii)(Phosporus deoxidised arsenical copper) |
- |
5100 |
|
- |
| Cl. No.8.1, Table no.3(Chemical Composition and Mechanical Properties of Brasses) |
- |
5100 |
|
- |
| Cl.no.8.1, Table no. 4(Chemical Composition and Mechanical Properties of Bronzes) |
- |
5100 |
|
- |
| Cl.no.9(Mechanical properties) |
- |
1500 |
|
- |
| Cl.no.10(Forgability Test) |
- |
0 |
|
- |
| Cl. No. 11(Mercurous Nitrate Test (For Forgings)) |
- |
1000 |
|
- |
| Cl. No.15(Marking) |
- |
200 |
|
- |
|
- |
- - |
| 11068 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 1079 (2017) |
Hot rolled carbon steel sheet, plate and strip - Specification (Seventh Revision) |
All type |
6750 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8(UTM) |
- |
1500 |
|
- |
| Cl 9(Press) |
- |
600 |
|
- |
| Cl 10(Die Press) |
- |
600 |
|
- |
| Cl 12(Workmanship) |
- |
200 |
|
- |
| Cl 13(Length, Width & Thickness) |
- |
600 |
|
- |
| 6.1(Carbon %) |
- |
300 |
|
- |
| 6.1(Manganese %) |
- |
300 |
|
- |
| 6.1(Phosphorus %) |
- |
300 |
|
- |
| 6.1(Sulphur %) |
- |
300 |
|
- |
| 6.1(Silicon %) |
- |
300 |
|
- |
| 6.1( Copper %) |
- |
300 |
|
- |
| 6.1( Aluminium %) |
- |
300 |
|
- |
| 6.1( Nb) |
- |
300 |
|
- |
| 6.1(V) |
- |
300 |
|
- |
| 6.1( Ti) |
- |
300 |
|
- |
| 6.1(Cr) |
- |
300 |
|
- |
| 6.1(Mo) |
- |
300 |
|
- |
| 6.1(Ni) |
- |
300 |
|
- |
| 6.1( Nitrogen%) |
- |
300 |
|
- |
| 6.1(Microalloying) |
- |
1500 |
|
- |
| Cl.13(Out of square) |
- |
300 |
|
- |
| Cl.13(Flatness) |
- |
500 |
|
- |
| Cl.13(Camber) |
- |
500 |
|
- |
| Cl.13(Width) |
- |
200 |
|
- |
| Cl.13(Thickness) |
- |
200 |
|
- |
| Cl. 8.3, Cl. 8.3.1
Table 5 and Table 6(Percentage Elongation After Fracture at 5.65√A Gauge length) |
- |
1000 |
|
- |
| Cl. 8.3, Cl. 8.3.1
Table 5 and Table 6(Percentage Elongation After Fracture at 80 mm Gauge length) |
- |
1000 |
|
- |
| Cl. 8.3, Cl. 8.3.1
Table 5 and Table 6(Percentage Elongation After Fracture at 50 mm Gauge length) |
- |
1000 |
|
- |
| Cl. 8.3, Cl. 8.3.1
Table 6(0.2% Proof Stress/Yield Stress) |
- |
1000 |
|
- |
| 14(Calculation of weight) |
- |
300 |
|
- |
| 8, Table 5 & 6(Tensile Strength) |
- |
1500 |
|
- |
| Clause 13(Length) |
- |
200 |
|
- |
|
- |
- - |
| 11069 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 1285 (2002) |
Wrought aluminium and aluminium alloys - Extruded round tube and hollow sections for general engineering purposes - Specification (Third Revision) |
All Type |
5500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5/5.1(FREEDOM FROM DEFECTS) |
- |
200 |
|
- |
| 5/5.2(FREEDOM FROM DEFECTS) |
- |
200 |
|
- |
| 6(Cl. 6 CONDITIONS OF SUPPLY) |
- |
200 |
|
- |
| 7/a) Extruded round tube IS 2673(DIMENSIONS AND TOLERANCE-Extruded round tube - outside Dia or Inside Dia) |
- |
200 |
|
- |
| 7 of IS 1285 /a) Extruded round tube IS 2673(DIMENSIONS AND TOLERANCE-Extruded round tube - outside Dia or Inside Dia) |
- |
200 |
|
- |
| 7 of IS 1285 /a) Extruded round tube IS 2673(DIMENSIONS AND TOLERANCE-Extruded round tube - Wall thickness) |
- |
200 |
|
- |
| 7 of IS 1285 /a) Extruded round tube IS 2673(DIMENSIONS AND TOLERANCE-Extruded round tube - Allowable Deviation of Mean Diameter from Specified Diameter (Size Tolerance)) |
- |
200 |
|
- |
| 7 of IS 1285 /a) Extruded round tube IS 2673(DIMENSIONS AND TOLERANCE-Extruded round tube - Allowabte Deviation of Diameter at Any Point from Specified Diameter (Ovality Tolcrance)) |
- |
200 |
|
- |
| 7 of IS 1285 /a) Extruded round tube IS 2673(DIMENSIONS AND TOLERANCE-Extruded round tube -Straightness) |
- |
200 |
|
- |
| 7 of IS 1285 /a) Extruded round tube IS 2673(DIMENSIONS AND TOLERANCE-Extruded round tube -Length) |
- |
200 |
|
- |
| 7 of IS 1285 / b) Extruded hollow sections IS 6477(DIMENSIONS AND TOLERANCE-Extruded hollow sections -SPECIFIED WIDTH or WIDTH ACROSS FLATS) |
- |
200 |
|
- |
| 7 of IS 1285 / b) Extruded hollow sections IS 6477(DIMENSIONS AND TOLERANCE-Extruded hollow sections - Specified WIDTH or WIDTH ACROSS FLATS) |
- |
200 |
|
- |
| 7 of IS 1285 / b) Extruded hollow sections IS 6477(DIMENSIONS AND TOLERANCE-Extruded hollow sections - Specified WIDTH or WIDTH ACROSS FLATS) |
- |
200 |
|
- |
| 7 of IS 1285 / b) Extruded hollow sections IS 6477(DIMENSIONS AND TOLERANCE-Extruded hollow sections -SPECIFIED Wall thickness) |
- |
200 |
|
- |
| 7 of IS 1285 / b) Extruded hollow sections IS 6477(DIMENSIONS AND TOLERANCE-Extruded hollow sections - Lengths) |
- |
200 |
|
- |
| 7 of IS 1285 / b) Extruded hollow sections IS 6477(DIMENSIONS AND TOLERANCE-Extruded hollow sections -Straightness) |
- |
200 |
|
- |
| 7 of IS 1285 / b) Extruded hollow sections IS 6477(DIMENSIONS AND TOLERANCE-Extruded hollow sections -Straightness) |
- |
200 |
|
- |
| 7 of IS 1285 / b) Extruded hollow sections IS 6477(DIMENSIONS AND TOLERANCE-Extruded hollow sections -Flatness) |
- |
200 |
|
- |
| 7 of IS 1285 / b) Extruded hollow sections IS 6477(DIMENSIONS AND TOLERANCE-Extruded hollow sections -Twist) |
- |
200 |
|
- |
| 7 of IS 1285 / b) Extruded hollow sections IS 6477(DIMENSIONS AND TOLERANCE-Extruded hollow sections -Twist) |
- |
200 |
|
- |
| 7 of IS 1285 / b) Extruded hollow sections IS 6477(Extruded hollow sections -Twist -Permissible Twist in Total Length of piece- degrees) |
- |
200 |
|
- |
| 7 of IS 1285 / b) Extruded hollow sections IS 6477(Extruded hollow sections -Twist -Permissible Twist in Total Length of piece- At extremetiy) |
- |
200 |
|
- |
| 7 of IS 1285 / b) Extruded hollow sections IS 6477(Extruded hollow sections -Twist -Permissible Twist, Maximum allowable in Total Length- degrees) |
- |
200 |
|
- |
| 7 of IS 1285 / b) Extruded hollow sections IS 6477(Extruded hollow sections -Twist -Permissible Twist Maximum allowable in Total Length- At extremetiy) |
- |
200 |
|
- |
| 7 of IS 1285 / b) Extruded hollow sections IS 6477("Extruded hollow sections -Twist -ALLOWABLE DEVIATION FROM
SPECIFIED ANGLE, DEGREES") |
- |
200 |
|
- |
| 9(Mechanical Comp[osition -IS 1285) |
- |
1900 |
|
- |
| 8(Chemical Composition - IS 1285) |
- |
2700 |
|
- |
| As per Clause 8 Table !(Aluminium) |
- |
300 |
|
- |
| As per Clause 8 Table !(Copper) |
- |
300 |
|
- |
| As per Clause 8 Table !(Magnesium) |
- |
300 |
|
- |
| As per Clause 8 Table !(Silicon) |
- |
300 |
|
- |
| As per Clause 8 Table !(Iron) |
- |
300 |
|
- |
| As per Clause 8 Table !(Manganese) |
- |
300 |
|
- |
| As per Clause 8 Table !(Zinc) |
- |
300 |
|
- |
| As per Clause 8 Table !(Titanium) |
- |
300 |
|
- |
| As per Clause 8 Table !(Chromium) |
- |
300 |
|
- |
| 12(Marking) |
- |
200 |
|
- |
|
- |
- - |
| 11070 |
DELHI TEST HOUSE, Azadhpur
| 8131406
| IS 17781 (2021) |
VITAMIN MINERAL PREMIX FOR MANUFACTURING FORTIFIED RICE KERNELS- SPECIFICATION |
- |
18000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Description) |
- |
500 |
|
- |
| 4.2(Vitamin and mineral premix shall be white to off
white in colour with faint odour. It shall be easy to use
and free from any objectionable or undesirable colour,
odour and foreign matter.) |
- |
500 |
|
- |
| 4.7 and 8 Table 1(i) Micronized ferric pyrophosphate) |
- |
500 |
|
- |
| 4.7 and 8 table 1(ii) Folic acid) |
- |
1000 |
|
- |
| 4.7 and 8 table 1(iii) Cyanocobalamine or hydroxycobalamine) |
- |
2000 |
|
- |
| 4.7 and 8 table 1(i) Zinc oxide (ZnO)) |
- |
2000 |
|
- |
| 4.7 and 8 table 1(ii) Retinyl palmitate) |
- |
2000 |
|
- |
| 4.7 and 8 table 1(iv) Thiamine hydrochloride or Thiamine mononitrate) |
- |
2000 |
|
- |
| 4.7 and 8 table 1(v) Riboflavin or riboflavin 5’-phosphate sodium) |
- |
2000 |
|
- |
| 4.7 and 8 table 1(vi) Nicotinamide or nicotinic acid) |
- |
2000 |
|
- |
| 4.7 and 8 table 1(vii) Pyridoxine hydrochloride) |
- |
2000 |
|
- |
| 4.9, 6.2 and 8(i) Moisture content, percent by mass, Max) |
- |
1000 |
|
- |
| 4.9, 6.2 and 8(ii) Particle size of micronized ferric pyrophosphate (D90 particles), µm) |
- |
1000 |
|
- |
|
17 Jun, 2027 |
- Included w.e.f. 11.09.2023 |