S.No. Lab Name Osl Code Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
11881 BIS, Patna Branch Laboratory (PBL) None IS 1161 (2014) Steel tubes for structural purposes - Specification (Fifth Revision) - - View breakup
-
- -
All test facilities are available as per the IS except- i. Galvanizing Test (Clause 8) ii. Cold Bend Test (Clause 11.3.1) iii. Tests for Chromium, Molybdenum,Vanadium, Nickel, Copper, Niobium, Boron, Titanium, Aluminium and Tungsten (Clause 5.1) Note: Sample size of 3m full length (two samples each of preferred size 1.5 m) may be supplied for testing. *- The exact sample type, size and quantity may be ascertained from the latest product manual issued by BIS.
11882 BIS, Southern Regional Laboratory (SRL) None IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
" 8 kg+300gm Excluding Except for Transverse strength (Optional test), Requirement for testing Alkali Content may be specifically mentioned.
11883 BIS, Central Laboratory (CL) None IS 2830 (2012) Carbon steel cast billet ingots, billets, blooms and slabs for re-rolling into steel for general structural purposes - Specification (Third Revision) - Rs. 5250/- View breakup
-
- -
-
11884 BIS, Northern Regional Laboratory (NRL) None IS 710 (2010) Marine plywood - Specification (Second Revision) - Rs 11200/- View breakup
-
- -
Test Facility is complete for Chemical and mechanical
11885 BIS, Patna Branch Laboratory (PBL) None IS 13592 (2013) Unplasticized Polyvinyl Chloride (PVC-U) Pipes for Soil and Waste Discharge System Inside and Outside Buiildings Including Ventilation and Rainwater System - - View breakup
-
- -
All test facilities are available as per the IS except- i. Water Tightness of Joint (Clause 11) ii. Effect on Water (Clause 8.6) iii.Resistance to dichloromethane at specified temperature (Clause 12)
11886 BIS, Northern Regional Laboratory (NRL) None IS 303 (1989) Plywood for General Purposes - - Rs 4000/- /BWR Grade, Rs.4900/- for MR Grade View breakup
-
- -
Excluding Steady State Formaldehyde Emission Test (Cl. 11.7)
11887 BIS, Southern Regional Laboratory (SRL) None IS 8042 (2015) White portland cement - Specification (Third Revision) - Rs 12050/- View breakup
-
- -
" 8 kg + 500 g Excluding Other than Transverse strength (Optional)
11888 BIS, Northern Regional Laboratory (NRL) None IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
Rs.8420/-
- -
Test Facility is complete for Chemical Except Transverse Strength Test
11889 BIS, Southern Regional Laboratory (SRL) None IS 651 (2007) Glazed stoneware pipes and fittings - Specification (Sixth Revision) - Rs. 6850/- View breakup
-
- -
" 2 x 2 nos. Excluding Hydrostatic test facility upto 300mm
11890 BIS, Southern Regional Laboratory (SRL) None IS 4246 (2002) Domestic gas stoves for use with liquefied petroleum gases - Specification (Fifth Revision) - - View breakup
-
- -
-
11891 BIS, Eastern Regional Laboratory (ERL) None IS 3812 (Part 1) (2013) Pulverized fuel ash - Specification: Part 1 For use as pozzolana in cement, cement mortar and concrete - Rs. 21850/- View breakup
-
- -
Type of Fuel ash to be declared, Declaration required regarding Moisture requirement
11892 BIS, Southern Regional Laboratory (SRL) None IS 13334 : Part 1 (2014) Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) - - View breakup
Rs.10430/-
- -
" 2x500g
11893 BIS, Central Laboratory (CL) None IS 1659 (2004) Block boards - Specification (Fourth Revision) - - View breakup
Rs 5900/- for BWR Grade, Rs.6800/- for MR grade
- -
SIZE: One Block Board Sample Size without dimensional measurements:Length-1200 mm, width-1200
11894 BIS, Bengaluru Branch Laboratory (BNBL) None IS 12786 (1989) Irrigation equipment - Polyethylene pipes for irrigation laterals - Specification - - View breakup
Rs. 7800.00 (Excluding Testing Charges for Material Test) Rs. 3600.00 (Testing Charges for Material Test)
- -
-
11895 BIS, Southern Regional Laboratory (SRL) None IS 12786 (1989) Irrigation equipment - Polyethylene pipes for irrigation laterals - Specification - - View breakup
-
- -
" 5m pc " Excluding excl hydraulic characteristics, Susceptibility to env stress cracking test, tensile test and Chem (material) test facility not available.
11896 BIS, Southern Regional Laboratory (SRL) None IS 7224 (2006) Iodized salt, vacuum evaporated iodized salt and refined iodized salt - Specification (Second Revision) Iodized salt, vacuum evaporated iodized salt & refined Rs7440/- View breakup
-
- -
-
11897 Dummy Lab (do not use) 7777777 IS 2095 : Part 1 (2011) Gypsum plaster boards - Specification: Part 1 plain gypsum plaster boards a 100 View breakup
-
24 May, 2025 -
-
11898 BIS, Southern Regional Laboratory (SRL) None IS 2062 (2011) Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) - - View breakup
-
- -
1 mt" Chemical Facility is available Quantity: 5 Pieces of 5cm X 5cm Excluding EXCEPT Y GROOVE CRACKABILITY TEST, Facility for preparation of test specimen not available for impact test
11899 BIS, Northern Regional Laboratory (NRL) None IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) - - View breakup
For category 01 Unsheathed cable: A Single Core, Plain Copper Conductor Rs. 10500/- B Single Core, Tinned Copper Conductor Rs.10800/- C Single Core, Solid Aluminium Conductor Rs.10200/- D Single Core, Stranded Aluminium ConductorRs.10200/- Sheathed Cable: A Single Core, Plain Copper Conductor Rs. 17550/- B Single Core, Tinned Copper Conductor Rs.17850/- C Single Core, Solid Aluminium ConductorRs.17250/- D Single Core, Stranded Aluminium Conductor Rs.17250/- For category 02 Unsheathed Cable: A Single Core, Plain Copper Conductor ?12150/- B Single Core, Tinned Copper Conductor ?12450/- C Single Core, Solid Aluminium Conductor ?11850/- D Single Core, Stranded Aluminium Conductor ?11850/- Sheathed Cable: A Single Core, Plain Copper Conductor ?18900/- B Single Core, Tinned Copper Conductor ?19200/- C Single Core, Solid Aluminium Conductor ?18600/- D Single Core, Stranded Aluminium Conductor ?18600/- For FR cables Unsheathed Cable: A Single Core, Plain Copper Conductor ?12600/- B Single Core, Tinned Copper Conductor ?12900/- C Single Core, Solid Aluminium Conductor ?12300/- D Single Core, Stranded Aluminium Conductor ?12300/- Sheathed Cable: A Single Core, Plain Copper Conductor ?19650/- B Single Core, Tinned Copper Conductor ?19950/- C Single Core, Solid Aluminium Conductor ?19350/- D Single Core, Stranded Aluminium Conductor ?19350/- For FR-LSH cables Unsheathed Cable A Single Core, Plain Copper Conductor ?13950/- B Single Core, Tinned Copper Conductor ?14250/- C Single Core, Solid Aluminium Conductor ?13650/- D Single Core, Stranded Aluminium Conductor ?13650/- Sheathed Cable: A Single Core, Plain Copper Conductor ?20820/- B Single Core, Tinned Copper Conductor ?21120/- C Single Core, Solid Aluminium Conductor ?20520/- D Single Core, Stranded Aluminium Conductor ?20520/- Material testing charges as per relevant referred Iss (For each of the above category). For multi core cable: for each additional core, the changes of single core unsheathed cable as per material (copper & aluminum) and as per construction of conductor (solid or standard, tinned or plain) shall be added
- -
Test Facility is complete
11900 BIS, Southern Regional Laboratory (SRL) None IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) - - View breakup
-
- -
" 1 mtr x3pcS. Chemical facility is available. Excluding EXCEPT Pullout TEST, Bend and Rebend, 0.2 percent proof stress/ yield stress, Total elongation at maximum force, bar size restricted upto 20 mm for TENSILE TEST
11901 BIS, Southern Regional Laboratory (SRL) None IS 2347 (2017) Domestic pressure cooker - Specification (Sixth Revision) - - View breakup
-
- -
" 1 No Excluding Excl Temp. Responsive Pressure Relief Device, Chromium over nickel plating, External Coating, Internal Coating and Chemical tests
11902 BIS, Eastern Regional Laboratory (ERL) None IS 2062 (2011) Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) For all grades except for the tests mentioned in remarks - View breakup
-
- -
Mech - Facility not available for NDT tests ; for impact test prepared pieces to be sent; Prepared test piece to be sent for Y groove crackability test. Chem- Facility not available for Microalloys & Al. Type of Killed material, Carbon Equivalent & Nitrogen content to be indicated in case the same are to be tested.
11903 BIS, Eastern Regional Laboratory (ERL) None IS 12818 (2010) Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) All sizes/types - View breakup
-
- -
Chemical: All except Effect on Water which is for Pipes above 60 mm Nominal dia and except for the requirement of 'Other Toxic Substances such a di-n-octyl Tin -s-s bis iso-octyl mercapto acetate' and 'butyl stearate'; Mech- All except HST.
11904 BIS, Eastern Regional Laboratory (ERL) None IS 4985 (2000) Unplasticized pvc pipes for potable water supplies - Specification (Third Revision) All sizes/varieties - View breakup
-
- -
Chemical: All except Effect on Water which is for Pipes above 60 mm Nominal dia and except for the requirement of 'Other Toxic Substances such a di-n-octyl Tin -s-s bis iso-octyl mercapto acetate' and 'butyl stearate'; Mech- All except HST.
11905 BIS, Eastern Regional Laboratory (ERL) None IS 2347 (2017) Domestic pressure cooker - Specification (Sixth Revision) - - View breakup
-
- -
Facility not available for Cl 8.6(test for Outer lid type),8.7,8.8,8.9,8.10,7.4, For Chemical tests, see status of IS for individual components (IS 21/6911/5522).
11906 BIS, Western Regional Laboratory (WRL) None IS 398 : Part 2 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) Up to 100 sq mm - View breakup
(I) For galvanized steel core only (consisting of 7 steel strands)- Rs.2850.00, (II) For galvanized steel reinforced stranded conductors with nominal aluminium area upto and including 100mm2-(a) For single steel wire core (1 steel + 6 Aluminium)- Rs. 1950.00 (b) For 7 wire core (7 steel + 6 Aluminium) - Rs. 4000.00, (III) For galvanized steel reinforced stranded conductors with nominal aluminium area more than 100mm2 (excluding special tests as per Cl. 13.9, 13.10 & 13.11)-(a) For stranded conductors with 37 strands-Rs.7900/-, (b) For stranded conductors with 49 strands-Rs.10000/-, (c) For stranded conductors with 61 strands-Rs.11100/-,
- -
Test facility not available for Cl. 13.9, 13.10 and 13.11 for size 100 sq.mm and above.
11907 BIS, Western Regional Laboratory (WRL) None IS 3854 (1997) Switches for domestic and similar purposes - Specification (Second Revision) - - View breakup
6A Screw type terminals-Rs.4900/-, 6A Screwless type terminals-Rs.5850/-,10A Screw type terminals-Rs.5050/-, 10A Screwless type terminals-Rs.6400/-, 16A Screw type terminals-Rs.5850/-,16A Screwless type terminals-Rs.7900/-, 20A-Rs.5250/-, 25A-Rs.5900/-, 32A-Rs.6250/-, 40A-Rs.6550/-, 63A-Rs.6200/-
- -
Complete TF is available for variety upto and including 20A. For above 20A rating (32A, 63A), the following facilities are not available: 1. Cl 17 Temperature rise 2. Cl 18, Making and breaking Capacity 3. Cl 19 Normal Operation"
11908 BIS, Eastern Regional Laboratory (ERL) None IS 398 : Part 2 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) Complete up to 100 sqmm - View breakup
-
- -
All tests are available up to and including 100 sq.mm. For Above 100 sq.mm. facility not available for Stress-Strain Test, Surface Condition, Ultimate B/L on stranded conductor.
11909 BIS, Eastern Regional Laboratory (ERL) None IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) For all grades except for the tests mentioned in remarks - View breakup
-
- -
Mech - Facility not available for pull out test, total elongation at maximum force. Chem- Facility not available for Micro-alloying elements. Declarations regarding type of 'Killed' material, Micro-alloys/low-alloys, Nitrogen content or any other parameter as per Note under clause 4.2 to be provided.
11910 BIS, Eastern Regional Laboratory (ERL) None IS 1554 : Part 1 (1988) Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) Complete for Cat 01(up to 400sq.mm)Except optional test - View breakup
Rs.16650/- for single core unarmoured cable, Rs.22500/- for two core, unarmoured cable, Rs.26700/- for two core armoured cable (Excluding addl. Type test for cables with improved fire performance.) For multi core cables, extra charges @ 35 % for each additional core shall be levied. Material testing charges as per relevant referred ISs Testing charges for Additional Type Tests for Improved Fire Performance Tests: Rs. 7100/- for category C1 Rs. 11700/- for category C2
- -
For Category-01 and upto 400 sq mm: all tests are available except additional tests. For cat. C1 and C2 : Except oxygen Index,Temperature index, Flame Retardance, Smoke Density, Halogen acid Gas Evolution

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.

Contact for any query/support: supportlims@bis.gov.in