11881 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 1161 (2014) |
Steel tubes for structural purposes - Specification (Fifth Revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 7 (Workmanship) |
- |
|
|
|
Cl 13 (Workmanship) |
- |
|
|
|
8 AND AS PER IS 4736 (UNIFORMITY OF ZINC COATING) |
- |
|
|
|
8 AND AS PER IS 4736 (MASS OF ZINC COATING) |
- |
|
|
|
5 AND AS PER IS 10748 (CARBON EQUIVALENT) |
- |
|
|
|
5 AND AS PER IS 10748 (CARBON) |
- |
|
|
|
Clause - 5.1, Table-3 (SILICON) |
- |
|
|
|
Clause - 5.1, Table-3 (NITROGEN) |
- |
|
|
|
Clause - 5.1, Table-3 (MANGANESE) |
- |
|
|
|
Clause - 5.1, Table-3 (PHOSPHURS) |
- |
|
|
|
Clause - 5.1, Table-3 (SULPHUR) |
- |
|
|
|
Clause - 5.1, Table-3 ( CARBON) |
- |
|
|
|
9 (Straightness) |
- |
|
|
|
10 (Lengths) |
- |
|
|
|
Clause 11.2, Table -2 (Elongation) |
- |
|
|
|
Clause 11.2, Table -2 (Yield Strength) |
- |
|
|
|
Cl 11.3.1 (Flattening test (over 50 mm NB)) |
- |
|
|
|
Cl 11.3.1 (Cold bend test (upto & including 50 mm NB)) |
- |
|
|
|
Cl. 6 , 6.2 Table 1 (Thickness) |
- |
|
|
|
Cl. 6 , 6.2 Table 1 (Weight) |
- |
|
|
|
Cl 11 (Tensile Test, Flattening Test & Cold Bend Test) |
- |
|
|
|
Cl 6 (Outer Diameter, Thickness & Mass) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS except-
i. Galvanizing Test (Clause 8)
ii. Cold Bend Test (Clause 11.3.1)
iii. Tests for Chromium, Molybdenum,Vanadium, Nickel, Copper, Niobium, Boron, Titanium, Aluminium and Tungsten (Clause 5.1)
Note: Sample size of 3m full length (two samples each of preferred size 1.5 m) may be supplied for testing.
*- The exact sample type, size and quantity may be ascertained from the latest product manual issued by BIS. |
11882 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 455 (2015) |
Portland slag cement - Specification |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 - Table - 1 i (Insoluble residue - Cl 6.9 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 ii (Magnesia - Cl 6.8 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 iii (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 6.11 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 v (Loss on ignition - Cl 6.2 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 vi (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
7 Table 1 iv c (Compretsive Strenqth 672 ± 4 hr
IS 4031(Part 6)) |
- |
|
|
|
7 Table 1 iv b (Compretsive Strenqth 168 ± 2 hr
IS 4031(Part 6)) |
- |
|
|
|
7 Table 1 iv a (Compretsive Strenqth .72 ± 1 hr
IS 4031(Part 6)) |
- |
|
|
|
7 Table 1 iii b (Setting Time ( by Vicat Apparatus ), Final
IS 4031(Part 5)) |
- |
|
|
|
7 Table 1 iii a (Setting Time ( by Vicat Apparatus ),Initial
IS 4031(Part 5)) |
- |
|
|
|
7 Table 1 ii b (Soundness, Autoclave expansion
IS 4031(Part 3) ) |
- |
|
|
|
7 Table 1 ii a (Soundness, Le-Chate1ier expansion
IS 4031(Part 3) ) |
- |
|
|
|
|
- |
- " 8 kg+300gm
Excluding Except for Transverse strength (Optional test), Requirement for testing Alkali Content may be specifically mentioned. |
11883 |
BIS, Central Laboratory (CL)
| None
| IS 2830 (2012) |
Carbon steel cast billet ingots, billets, blooms and slabs for re-rolling into steel for general structural purposes - Specification (Third Revision) |
- |
Rs. 5250/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 9 (Workmanship) |
- |
|
|
|
Cl 10.2 (Workmanship) |
- |
|
|
|
Cl 10.3 (Workmanship) |
- |
|
|
|
Cl 11 (Length, Width & Thickness) |
- |
|
|
|
6.1 (Carbon %) |
- |
|
|
|
6.1 (Sulphur %) |
- |
|
|
|
6.1 (Phosphorus %) |
- |
|
|
|
6.1 (Silicon %) |
- |
|
|
|
6.1 ( Aluminium %) |
- |
|
|
|
6.1 ( Nitrogen%) |
- |
|
|
|
6 (Sulphur + Phosphorus) |
- |
|
|
|
6.1 ( Nb) |
- |
|
|
|
6.1 (V) |
- |
|
|
|
6.1 ( Ti) |
- |
|
|
|
6 (carbon equivalent (CE)) |
- |
|
|
|
6 (Copper as Cu) |
- |
|
|
|
Clause 6, Table 1 Note : 3 (Nb+V+Ti) |
- |
|
|
|
6.1 (Cr) |
- |
|
|
|
6.1 (Mo) |
- |
|
|
|
6.1 (Ni) |
- |
|
|
|
Cl 6.1 (Manganese) |
- |
|
|
|
|
- |
- - |
11884 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 710 (2010) |
Marine plywood - Specification (Second Revision) |
- |
Rs 11200/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1 (DIMENSIONS) |
- |
|
|
|
6.1 (DIMENSIONS) |
- |
|
|
|
6.2 (DIMENSIONS) |
- |
|
|
|
6.3 (DIMENSIONS) |
- |
|
|
|
6.3 (DIMENSIONS) |
- |
|
|
|
9.1.1 (MOISTURE CONTENT) |
- |
|
|
|
9.1.2 , 9.1.2.2 (Glue Adhesion in Dry State) |
- |
|
|
|
9.1.3 , 9.1.3.1.2 (Water resistance test) |
- |
|
|
|
9.1.5 , 9.1.3.1.1 (Mycological test) |
- |
|
|
|
6.1 (DIMENSIONS) |
- |
|
|
|
9.1.2 , 9.1.2.2 (Glue Adhesion in Dry State) |
- |
|
|
|
9.1.3 , 9.1.3.1.2 (Water resistance test) |
- |
|
|
|
9.1.5 , 9.1.3.1.2 (Mycological test) |
- |
|
|
|
9.1.8 (Retention of preservative) |
- |
|
|
|
11.2 (MARKING) |
- |
|
|
|
11.1 (MARKING) |
- |
|
|
|
7.1 (WORKMANSHIP AND FINISH ) |
- |
|
|
|
7.2 (WORKMANSHIP AND FINISH ) |
- |
|
|
|
7.3 (WORKMANSHIP AND FINISH ) |
- |
|
|
|
7.5 (WORKMANSHIP AND FINISH ) |
- |
|
|
|
9.1.5 (Mycological test) |
- |
|
|
|
Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Rupture: Across the Face Grain: Minimum Individual)) |
- |
|
|
|
Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Rupture: Across the Face Grain: Average)) |
- |
|
|
|
Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Rupture: Along the Face Grain: Minimum Individual)) |
- |
|
|
|
Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Rupture: Along the Face Grain: Average)) |
- |
|
|
|
Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Elasticity: Across the Face Grain: Minimum Individual)) |
- |
|
|
|
Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Elasticity: Across the Face Grain: Average)) |
- |
|
|
|
Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Elasticity: Along the Face Grain: Minimum Individual)) |
- |
|
|
|
Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Elasticity: Along the Face Grain: Average)) |
- |
|
|
|
Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Rupture: Across the Face Grain: Minimum Individual)) |
- |
|
|
|
Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Rupture: Across the Face Grain: Average)) |
- |
|
|
|
Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Rupture: Along the Face Grain: Minimum Individual)) |
- |
|
|
|
Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Rupture: Along the Face Grain: Average)) |
- |
|
|
|
Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Elasticity: Across the Face Grain: Minimum Individual)) |
- |
|
|
|
Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Elasticity: Across the Face Grain: Average)) |
- |
|
|
|
Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Elasticity: Along the Face Grain: Minimum Individual)) |
- |
|
|
|
Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Elasticity: Along the Face Grain: Average)) |
- |
|
|
|
Cl. 9.1.4 (Cl. 9.1.4 (Tensile Strength: Sum of the Tensile Strength in two directions)) |
- |
|
|
|
Cl. 9.1.4 (Cl. 9.1.4 (Tensile Strength: Perpendicular to grain)) |
- |
|
|
|
Cl. 9.1.4 (Cl. 9.1.4 (Tensile Strength: Parallel to grain)) |
- |
|
|
|
Cl.9.1.5,9.1.3.1.1 (Cl.9.1.5 (Mycological Test),9.1.3.1.1 (Glue Shear Strength: Individual)) |
- |
|
|
|
Cl.9.1.5,9.1.3.1.1 (Cl.9.1.5 (Mycological Test),9.1.3.1.1 ( Glue Shear Strength: Average)) |
- |
|
|
|
Cl. 9.1.3, 9.1.3.1.1 (Cl. 9.1.3 (Water Resistance Test) , 9.1.3.1.1 (Glue Shear Strength: Individual)) |
- |
|
|
|
Cl. 9.1.3, 9.1.3.1.1 (Cl. 9.1.3 (Water Resistance Test ), 9.1.3.1.1 (Glue Shear Strength: Average)) |
- |
|
|
|
Cl. 9.1.2, 9.1.2.1 (Cl. 9.1.2 (Glue Adhesion in Dry State), 9.1.2.1 ( Glue Shear Strength: Individual)) |
- |
|
|
|
Cl. 9.1.2, 9.1.2.1 (Cl. 9.1.2 (Glue Adhesion in Dry State), 9.1.2.1 ( Glue Shear Strength: Average )) |
- |
|
|
|
|
- |
- Test Facility is complete for Chemical and mechanical |
11885 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 13592 (2013) |
Unplasticized Polyvinyl Chloride (PVC-U) Pipes for Soil and Waste Discharge System Inside and Outside Buiildings Including Ventilation and Rainwater System |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.5 (Surface colour of the pipes shall be dark shade of grey) |
- |
|
|
|
Cl.7.1 (Mean outside diameter, outside diameter at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
|
|
|
Cl.7.1 ( outside diameter at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
|
|
|
Cl.7.1 ( wall thickness at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
|
|
|
Cl.7.2 (Pipes shall be supplied in nominal lengths of 2, 3, 4 or
6 metres either plain or with socket for solvent
cementing/grooved socket. Tolerances on specified
length shall be + 10 mm and – 0 mm.The nominal length of the pipe with socket for solvent
cementing/grooved socket shall be as given in Fig. 1.) |
- |
|
|
|
Cl.7.3.1 (Minimum wall thickness of socket on pipes shall
be as given in Table 2 read with Fig. 2 and Fig. 3.) |
- |
|
|
|
Cl.7.3.2 (Dimensions of sockets for solvent cementing and
grooved sockets of pipes shall be as given in Tables 3
and 4 respectively, read with Fig. 2 and 3.) |
- |
|
|
|
Cl.8.1 (The internal and external surface of the pipes shall be
smooth and clean, and free from grooving and other
defects. The end shall be clearly cut and shall be square
with the axis of the pipe. The end may be chamfered
on the plain side.) |
- |
|
|
|
Cl.8.2 (When tested by the method described in IS 12235
(Part 5), a length of pipe sample of 200 ± 20 mm shall
not alter in length by more than 5 percent. In the case
of socket ended pipes, this test shall be carried out on
the plain portion of pipe taken at least 100 mm away
from the root of the socket.) |
- |
|
|
|
Cl8.3 (This test shall be carried out for socket end pipes only.
When tested by the method described in IS 12235
(Part 6), the test specimens shall not show blisters,
excessive delamination or cracking or signs of weld
line splitting.) |
- |
|
|
|
Cl.10.2 (When determined in accordance with the method
described in IS 12235 (Part 13), the tensile strength at
break shall not be less than 45 MPa.) |
- |
|
|
|
Cl.10.3 (The axial shrinkage shall not exceed 2 percent when
determined in accordance with Annex B.) |
- |
|
|
|
Cl.8.4 (When determined in accordance with IS 12235 (Part 2),
the vicat softening temperature of the specimen shall
not be less than 79°C.) |
- |
|
|
|
Cl. 9, IS 12235 Part 7 (Resistance to Sulphuric Acid) |
- |
|
|
|
Cl.10.1 (When tested by method prescribed in IS 12235 (Part 9),the pipe shall have a true impact rate of not more than
10 percent. Mass of striker and height of fall shall be
as per Annex A.) |
- |
|
|
|
Cl. 12, IS 12235 Part 11 (Resistance to Di-Chloro-Methane) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS except-
i. Water Tightness of Joint (Clause 11)
ii. Effect on Water (Clause 8.6)
iii.Resistance to dichloromethane at specified temperature (Clause 12) |
11886 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 303 (1989) |
Plywood for General Purposes - |
- |
Rs 4000/- /BWR Grade, Rs.4900/- for MR Grade View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
11.4, Table 4 (Static Bending Strength - Modulus of Rupture - Across the Face Grain - Minimum Individual) |
- |
|
|
|
11.4, Table 4 (Static Bending Strength - Modulus of Rupture - Across the Face Grain - Average) |
- |
|
|
|
11.4, Table 4 (Static Bending Strength - Modulus of Rupture - Along the Face Grain - Minimum Individual) |
- |
|
|
|
11.4, Table 4 (Static Bending Strength - Modulus of Rupture - Along the Face Grain - Average) |
- |
|
|
|
11.4, Table 4 (Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Minimum Individual) |
- |
|
|
|
11.4, Table 4 (Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Average) |
- |
|
|
|
11.4, Table 4 (Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
|
|
|
11.4, Table 4 (Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
|
|
|
11.2.2 (Glue Adhesion - Mycological test - 11.2.2, Part 7 of IS 1734 [for MR Garde only]) |
- |
|
|
|
11.2.1 (Glue Adhesion - Water resistance test - 11.2.1.1 [for MR Grade]) |
- |
|
|
|
11.2.1 (Glue Adhesion - Water resistance test - 11.2.1.1 [for BWR Grade]) |
- |
|
|
|
11.3 (Moisture Content - Part 1 of IS 1734) |
- |
|
|
|
8 (Dimensions & Tolerances - Edge Straightness - Annexure C) |
- |
|
|
|
8 (Dimensions & Tolerances - Squareness - Annexure C) |
- |
|
|
|
8 (Dimensions & Tolerances - Thickness - Cl. 8) |
- |
|
|
|
8 (Dimensions & Tolerances - Width - Cl. 8) |
- |
|
|
|
8 (Dimensions & Tolerances - Length - Cl. 8) |
- |
|
|
|
9 (Workmanship and Finish - Cl.9, 8.3, Annexure C) |
- |
|
|
|
5.2, Table 1, Table 2 (Quality Requirements - Cl. 5.2) |
- |
|
|
|
5.1 (Type - For BB Type) |
- |
|
|
|
5.1 (Type - For AB Type) |
- |
|
|
|
5.1 (Type - For AA Type) |
- |
|
|
|
|
- |
- Excluding Steady State Formaldehyde Emission Test (Cl. 11.7) |
11887 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 8042 (2015) |
White portland cement - Specification (Third Revision) |
- |
Rs 12050/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5 - Table - 1 i (Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
5 - Table - 1 ii (Iron oxide - Cl 4.5 of IS 4032:1985) |
- |
|
|
|
5 - Table - 1 iii (Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
|
|
|
5 - Table - 1 iv (Magnesia - Cl 4.8 of IS 4032:1985) |
- |
|
|
|
5 - Table - 1 v (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
|
|
|
5 - Table - 1 vi (Loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
|
|
|
5 - Table - 1 vii (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
6 -Table 2- i (Fineness 4031 Part 2) |
- |
|
|
|
6 -Table 2- ii- a (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
6 -Table 2- ii- b (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
6 -Table 2- iii- a (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
6 -Table 2-iii- b (Setting Time Final- 4031 Part 5) |
- |
|
|
|
6 -Table 2- iv- a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
6 -Table 2- iv- b (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
6 -Table 2- iv- c (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
|
- |
- " 8 kg + 500 g
Excluding Other than Transverse strength (Optional) |
11888 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 1489 (Part 1) (2015) |
Portland pozzolana cement - Specification: Part 1 fly Ash Based |
- |
- View breakup
Rs.8420/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7 -Table 2- iv- a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
7 -Table 2- iv- b (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
7 -Table 2- iv- c (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
7 -Table 2- iv- a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
7 -Table 2- iv- b (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
7 -Table 2- iv- c (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
7 -Table 2- vi (Drying Shrinkage- IS 4031 Part 10) |
- |
|
|
|
7 -Table 2- iii- a (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
7 -Table 2- vi (Drying Shrinkage- IS 4031 Part 10) |
- |
|
|
|
7 -Table 2- iii- a (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
7 -Table 2-iii- b (Setting Time Final- 4031 Part 5) |
- |
|
|
|
7 -Table 2- iii- a (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
7 -Table 2- ii- b (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
7 -Table 2- ii- a (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
7 -Table 2- ii- b (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
7 -Table 2- ii- a (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
7 -Table 2- i (Fineness 4031 Part 2) |
- |
|
|
|
7 -Table 2- ii- a (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
7 -Table 2- i (Fineness 4031 Part 2) |
- |
|
|
|
7 -Table 2- ii- b (Expansion after aeration- 4031 Part 3) |
- |
|
|
|
7 -Table 2- ii- a (Expansion after aeration - 4031 Part 3) |
- |
|
|
|
6 - Table - 1 vi ( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 iv (Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 i (Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 iii (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 v (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 ii (Magnesia - Cl 7.2 of IS 4032:1985) |
- |
|
|
|
|
- |
- Test Facility is complete for Chemical
Except Transverse Strength Test |
11889 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 651 (2007) |
Glazed stoneware pipes and fittings - Specification (Sixth Revision) |
- |
Rs. 6850/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 7.4 (Acid Resistance Test) |
- |
|
|
|
Clause 7.5 (Alkali Resistance Test) |
- |
|
|
|
7.2 (Hydraulic Test) |
- |
|
|
|
7.3 (Absorption Test) |
- |
|
|
|
10.1-Table 1 (INTERNAL DIAMETER) |
- |
|
|
|
11.1-Table 1 (
Mean Thickness of Barrel and of Socket) |
- |
|
|
|
14-Table 1 (Internal Depth of Socket) |
- |
|
|
|
14-Table 3 (Length of Grooving of Spigot) |
- |
|
|
|
14 (The interior of the sockets shall be conical, having a minimum taper) |
- |
|
|
|
5.1 (GENERAL QUALITY) |
- |
|
|
|
5.1 (GENERAL QUALITY) |
- |
|
|
|
5.2(a) (GENERAL QUALITY) |
- |
|
|
|
5.2(b) (GENERAL QUALITY) |
- |
|
|
|
5.2(c) (GENERAL QUALITY) |
- |
|
|
|
6 ( GLAZING) |
- |
|
|
|
7.3 (Absorption Test) |
- |
|
|
|
14-Table 2 (Excess Shoulder Measurment) |
- |
|
|
|
14-Table 3 (Length of Grooving of Spigot) |
- |
|
|
|
12.2 (STRAIGHTNESS OF BARRELS OR STRAIGHT AND TAPER PIPES-Length of Junction) |
- |
|
|
|
13.1-Table 2 (Dimensions of One-Quarter Bends-Internal Diameter) |
- |
|
|
|
13.1-Table 2 (Dimensions of One-Quarter Bends-r) |
- |
|
|
|
13.1-Table 2 (Dimensions of One-Quarter Bends-a) |
- |
|
|
|
13.1-Table 2 (Dimensions of One-Quarter Bends-angle) |
- |
|
|
|
13.1-Table 3 (Dimensions of One-Eighth Bends--Internal Diameter) |
- |
|
|
|
13.1-Table 3 (Dimensions of One-Eighth Bends-r) |
- |
|
|
|
13.1-Table 3 (Dimensions of One-Eighth Bends-angle) |
- |
|
|
|
13.1-Table 4 (Dimension of One-Sixteenth Bends-Internal Diameter) |
- |
|
|
|
13.1-Table 5 (Dimension of One-Quarter Taper Bends-d) |
- |
|
|
|
13.1-Table 5 (Dimension of One-Quarter Taper Bends-D) |
- |
|
|
|
13.1-Table 5 (Dimension of One-Quarter Taper Bends-r) |
- |
|
|
|
13.1-Table 5 (Dimension of One-Quarter Taper Bends-a) |
- |
|
|
|
13.1-Table 5 (Dimension of One-Quarter Taper Bends-Angle) |
- |
|
|
|
13.1-Table 6 (Dimensions of One-Eighth Taper Bends-d) |
- |
|
|
|
13.1-Table 6 (Dimensions of One-Eighth Taper Bends-D) |
- |
|
|
|
13.2 (The angle at junction) |
- |
|
|
|
14 (The interior of the sockets shall be conical, having a minimum taper) |
- |
|
|
|
15 (GROOVING Length) |
- |
|
|
|
15 (GROOVING Depth) |
- |
|
|
|
17-Table 7 (Dimensions of Half-Section One-Quarter Channel Bends-Internal Diameter) |
- |
|
|
|
17-Table 7 (Dimensions of Half-Section One-Quarter Channel Bends-r) |
- |
|
|
|
17-Table 7 (Dimensions of Half-Section One-Quarter Channel Bends-a) |
- |
|
|
|
17-Table 7 (Dimensions of Half-Section One-Quarter Channel Bends-Angle) |
- |
|
|
|
17-Table 8 (Dimensions of Half-Section One-Eighth Channel Bends-Internal Diameter) |
- |
|
|
|
17-Table 8 (Dimensions of Half-Section One-Eighth Channel Bends-Angle) |
- |
|
|
|
17-Table 9 (Dimensions of Half-Section One-Sixteenth Channel Bends-Internal Diameter) |
- |
|
|
|
17-Table 10 (Dimensions of Channel Interceptors-Internal Diameter) |
- |
|
|
|
17-Table 10 (Dimensions of Channel Interceptors-A) |
- |
|
|
|
17-Table 10 (Dimensions of Channel Interceptors-B) |
- |
|
|
|
17-Table 10 (Dimensions of Channel Interceptors-C) |
- |
|
|
|
17-Table 10 (Dimensions of Channel Interceptors-D) |
- |
|
|
|
17-Table 10 (Dimensions of Channel Interceptors-E) |
- |
|
|
|
17-Table 10 (Dimensions of Channel Interceptors-F) |
- |
|
|
|
17-Table 10 (Dimensions of Channel Interceptors-G) |
- |
|
|
|
17-Table 11 (Dimensions of Round Mouth Gully traps-Type) |
- |
|
|
|
17-Table 11 (Dimensions of Round Mouth Gully traps-Size) |
- |
|
|
|
17-Table 11 (Dimensions of Round Mouth Gully traps-A) |
- |
|
|
|
17-Table 11 (Dimensions of Round Mouth Gully traps-C) |
- |
|
|
|
17-Table 11 (Dimensions of Round Mouth Gully traps-d) |
- |
|
|
|
17-Table 11 (Dimensions of Round Mouth Gully traps-D) |
- |
|
|
|
17-Table 11 (Dimensions of Round Mouth Gully traps-D') |
- |
|
|
|
17-Table 11 (Dimensions of Round Mouth Gully traps-E) |
- |
|
|
|
17-Table 11 (Dimensions of Round Mouth Gully traps-F) |
- |
|
|
|
17-Table 11 (Dimensions of Round Mouth Gully traps-F') |
- |
|
|
|
17-Table 11 (Dimensions of Round Mouth Gully traps-G) |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-Type) |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-Size) |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-A) |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-C) |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-d) |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-D) |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-D') |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-E) |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-F) |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-F') |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-G) |
- |
|
|
|
|
- |
- " 2 x 2 nos.
Excluding Hydrostatic test facility upto 300mm |
11890 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 4246 (2002) |
Domestic gas stoves for use with liquefied petroleum gases - Specification (Fifth Revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.24(Annexure E) (on no account the carbon monoxidel
carbon dioxide ratio of the exhaust gases of any burner.
operating at any consumption at which the burner is
stable at gas inlet pressure from 2452 kN/m2 to
3432 kN/m2 (25 gf/cm2 to 35 gf/cm2), exceed 0.02.) |
- |
|
|
|
Cl.23 (There shall be no extinction of the flames on any
of the burners operating at maximum consumption
when the appliance is placed in a general (not
localized) current of air with a velocity of 2 m/s, as
measured with a rotating vane anemometer. The
location of the appliance relative to neighboring walls
and the direction of the draught shall be varied to
correspond to likely conditions of appliance installation.
This applies for all pressures from 2452 kN/m2 to
3432 kN/m2 (25 gf/cm2 to 35 gf/cm2).) |
- |
|
|
|
|
- |
- - |
11891 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 3812 (Part 1) (2013) |
Pulverized fuel ash - Specification: Part 1 For use as pozzolana in cement, cement mortar and concrete |
- |
Rs. 21850/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 6.1, Table 1 - i (Silicon dioxide (SiO2) plus aluminium oxide (Al2O3) plus ironoxide (Fe2O3) - IS 1727) |
- |
|
|
|
Cl. 6.1, Table 1 - ii (Silicon dioxide (SiO2) - IS 1727) |
- |
|
|
|
Cl. 6.1, Table 1 - iv (Magnesium oxide (MgO) - IS 1727) |
- |
|
|
|
Cl. 6.1, Table 1 - v ( Total sulphur as sulphur trioxide (SO3) - IS 1727) |
- |
|
|
|
Cl. 6.1, Table 1 - vi ( Available alkalis as equivalent sodium oxide (Na2O) - Annex C) |
- |
|
|
|
Cl. 6.1, Table 1 - vii ( Total Chlorides - IS 4032) |
- |
|
|
|
Cl. 6.1, Table 1 - viii ( Loss on ignition - IS 1727) |
- |
|
|
|
Cl. 6.2 (Moisture content of the fly ash when supplied in dry condition - Annex D) |
- |
|
|
|
7.1-Table 2(iv) (PHYSICAL REQUIREMENTS-Compressive strength at 28 days) |
- |
|
|
|
7.1-Table 2(v) (PHYSICAL REQUIREMENTS-Soundness by autoclave test ) |
- |
|
|
|
7.1-Table 2(i) (PHYSICAL REQUIREMENTS-Fineness) |
- |
|
|
|
Cl. 6.1, Table 1 - iii (Reactive Silica - Annex B) |
- |
|
|
|
5.1, 7.1, table-2, iii (Lime reacitivity) |
- |
|
|
|
|
- |
- Type of Fuel ash to be declared, Declaration required regarding Moisture requirement |
11892 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 13334 : Part 1 (2014) |
Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) |
- |
- View breakup
Rs.10430/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5.4 (The flavour of the product or of the reconstituted
milk shall be pleasant and clean (see IS 10030).) |
- |
|
|
|
4 (Description) |
- |
|
|
|
5.6 (Moisture) |
- |
|
|
|
5.6 (Milk protein in milk solids not fat) |
- |
|
|
|
5.6 (Milk fat) |
- |
|
|
|
5.6 (Insolubility index) |
- |
|
|
|
5.6 (Milk fat) |
- |
|
|
|
5.6 (Total ash (on dry basis)) |
- |
|
|
|
5.6 (Titratable acidity (lactic acid)) |
- |
|
|
|
5.6 (Scorched particles) |
- |
|
|
|
5.6 (Bacterial count) |
- |
|
|
|
5.6 (Coliform count ) |
- |
|
|
|
5.6 (Escherichia coli) |
- |
|
|
|
5.6 (Coagulase positive Staphylococcus aureus) |
- |
|
|
|
5.6 (Salmonella) |
- |
|
|
|
5.6 (Spore count, Aerobic (Bacillus cereus)) |
- |
|
|
|
5.6 (Spore count, Anaerobic (Sulfite reducing Clostridia)) |
- |
|
|
|
5.6 (Listeria monocytogenes) |
- |
|
|
|
|
- |
- " 2x500g |
11893 |
BIS, Central Laboratory (CL)
| None
| IS 1659 (2004) |
Block boards - Specification (Fourth Revision) |
- |
- View breakup
Rs 5900/- for BWR Grade, Rs.6800/- for MR grade
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9.2.6 (Spot test - Annexure L) |
- |
|
|
|
9.2.5 (Modulus of elasticity - MINIMUM INDIVIDUAL - Annexure K) |
- |
|
|
|
9.2.5 (Modulus of elasticity - AVERAGE - Annexure K) |
- |
|
|
|
9.2.5 (Modulus of rupture - MINIMUM INDIVIDUAL - Annexure K) |
- |
|
|
|
9.2.5 (Modulus of rupture - AVERAGE - Annexure K) |
- |
|
|
|
9.2.4 (Mycological Test [for MR grade only] - Annexure J) |
- |
|
|
|
9.2.3 (Adhesion of Plies - Annexure H) |
- |
|
|
|
9.2.2 (Resistance to water - Annexure G, Annexure H [For MR Grade]) |
- |
|
|
|
9.2.2 (Resistance to water - Annexure G, Annexure H [For BWP grade]) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity Change in local planeness - Annexure F) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity - Delamination - Annexure F) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity - Change in thickness - at 40% RH - Annexure F) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity - Change in Thickness - at 90% RH - Annexure F) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity - Change in Length - at 40% RH - Annexure F) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity - Change in Length - at 90% RH - Annexure F) |
- |
|
|
|
7.3 (Dimensional Requirements - Variation in thickness - Annexure E) |
- |
|
|
|
7.3 (Dimensional Requirements - Squareness - Annexure D) |
- |
|
|
|
7.3 (Dimensional Requirements - Edge Straightness - Annexure D) |
- |
|
|
|
7.3 (Dimensional Requirements - Thickness - Annexure E) |
- |
|
|
|
7.3 (Dimensional Requirements - Width - 8.1.4) |
- |
|
|
|
7.3 (Dimensional Requirements - Length - 8.1.4) |
- |
|
|
|
8.1.3, 6.3.3, IS 1328 (Visual Inspection - Permissible Defects - IS 1328 [test method for DECORATIVE type]) |
- |
|
|
|
8.1.3, 6.3.3, IS 303 (Visual Inspection - Permissible Defects - IS 303 [test method for COMMERCIAL type]) |
- |
|
|
|
9.2.6 (mechanical) (Spot test - Annexure L) |
- |
|
|
|
|
- |
- SIZE: One Block Board
Sample Size without dimensional measurements:Length-1200 mm, width-1200 |
11894 |
BIS, Bengaluru Branch Laboratory (BNBL)
| None
| IS 12786 (1989) |
Irrigation equipment - Polyethylene pipes for irrigation laterals - Specification |
- |
- View breakup
Rs. 7800.00 (Excluding Testing Charges for Material Test) Rs. 3600.00 (Testing Charges for Material Test)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1.c & 4.2.a (Carbon Black content - IS 2530 : 1963) |
- |
|
|
|
4.2.b (The dispersion of Carbon Black content shall be satisfactory - IS 2530 : 1963) |
- |
|
|
|
4.1.c & 4.2.a (Carbon Black content - IS 2530 : 1963) |
- |
|
|
|
7.3 (Tensile Test) |
- |
|
|
|
7.3 (Elongation at Break) |
- |
|
|
|
7.4 (SusceptibiIity to Environmental Stress
Cracking) |
- |
|
|
|
5 and Table 1 (DIMENSIONS OF PIPES - outside diameters) |
- |
|
|
|
5 and Table 1 (DIMENSIONS OF PIPES - wall thickness shall) |
- |
|
|
|
7.2 (Reversion Test) |
- |
|
|
|
3.1 (Class of Pipe) |
- |
|
|
|
6.1 (Visual Appearance) |
- |
|
|
|
7.1 (Hydraulic Characteristics) |
- |
|
|
|
7.1 (Hydraulic Characteristics) |
- |
|
|
|
|
- |
- - |
11895 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 12786 (1989) |
Irrigation equipment - Polyethylene pipes for irrigation laterals - Specification |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5 and Table 1 (DIMENSIONS OF PIPES - outside diameters) |
- |
|
|
|
5 and Table 1 (DIMENSIONS OF PIPES - wall thickness shall) |
- |
|
|
|
7.2 (Reversion Test) |
- |
|
|
|
|
- |
- " 5m pc "
Excluding excl hydraulic characteristics, Susceptibility to env stress cracking test, tensile test and Chem (material) test facility not available. |
11896 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 7224 (2006) |
Iodized salt, vacuum evaporated iodized salt and refined iodized salt - Specification (Second Revision) |
Iodized salt, vacuum evaporated iodized salt & refined |
Rs7440/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 4.2 (Particle Size) |
- |
|
|
|
Clause 4.3 Table 1 (Moisture content) |
- |
|
|
|
Clause 4.3 Table 1 (water insoluble matter) |
- |
|
|
|
Clause 4.3 Table 1 (Chloride Content(as Nacl)) |
- |
|
|
|
Clause 4.3 Table 1 (Matter soluble in water other than sodium chloride) |
- |
|
|
|
Clause 4.3 Table 1 (Calcium (as Ca)) |
- |
|
|
|
Clause 4.3 Table 1 (Magnesium (as mg)) |
- |
|
|
|
Clause 4.3 Table 1 (Sulphate (as SO4 ),) |
- |
|
|
|
Clause 4.3 Table 1 (Iodine content, a) Manufacturers Level ) |
- |
|
|
|
Clause 4.3 Table 1 (b) Distribution channel including retailer) |
- |
|
|
|
Clause 4.3 Table 1 (Alkalinity (as Na2CO3),) |
- |
|
|
|
Clause 4.3 Table 1 (Lead as (Pb)) |
- |
|
|
|
Clause 4.3 Table 1 (Arsenic(as As)) |
- |
|
|
|
Clause 4.3 Table 1 (Iron(as Fe)) |
- |
|
|
|
Clause 4.3 Table 1 (Lead as (Pb)) |
- |
|
|
|
Clause 4.3 Table 1 (Arsenic(as As)) |
- |
|
|
|
Clause 4.3 Table 1 (Iron(as Fe)) |
- |
|
|
|
Clause 4.2 (Particle Size) |
- |
|
|
|
4.4 (Anticaking agents (Potassium Ferrocyanide)) |
- |
|
|
|
Clause no4.1 (Description) |
- |
|
|
|
|
- |
- - |
11897 |
Dummy Lab (do not use)
| 7777777
| IS 2095 : Part 1 (2011) |
Gypsum plaster boards - Specification: Part 1 plain gypsum plaster boards |
a |
100 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1 (Ref. Cl 4.1, Table 1 of IS 2547(I) : 1996)(Soluble Sodium salts expressed as Na2O, Appendix A) |
- |
1 |
|
zcsdm |
10(FINISH) |
- |
1 |
|
sfsdf |
5.1 (Ref. Cl 4.1, Table 1 of IS 2547(I) : 1996)(Soluble Sodium salts expressed as Na2O, Appendix A) |
- |
0 |
|
- |
|
24 May, 2025 |
- - |
11898 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 2062 (2011) |
Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 18 (Weight) |
- |
|
|
|
Cl 15 (Length, Width & Thickness) |
- |
|
|
|
Cl 12 (Sudden Load Applied) |
- |
|
|
|
Cl 10.3 (UTM) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E650, CARBON +EQUIVELENT ) |
- |
|
|
|
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650) (Vanadium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650) (Molybdenum- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650) (Chromium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650) (Nickel- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650) (Copper- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650) (Carbon Equivalent- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650) (Nitrogen- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650) (Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650) (Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650) (Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650) (Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650) (Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Clause 8, Table 1, Note 2 (Aluminium) |
- |
|
|
|
Clause 8, Table 1, Note 5 (Niobium) |
- |
|
|
|
Clause 8, Table 1, Note 5 (Titanium) |
- |
|
|
|
Clause 8, Table 1, Note 5 (Nb+V+Ti) |
- |
|
|
|
Clause 8, Table 1, Note 6 (Boron) |
- |
|
|
|
Clause 8, Table 1, Note 6 (Cr+Ni) |
- |
|
|
|
|
- |
- 1 mt" Chemical Facility is available Quantity: 5 Pieces of 5cm X 5cm
Excluding EXCEPT Y GROOVE CRACKABILITY TEST, Facility for preparation of test specimen not available for impact test |
11899 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
- |
- View breakup
For category 01 Unsheathed cable: A Single Core, Plain Copper Conductor Rs. 10500/- B Single Core, Tinned Copper Conductor Rs.10800/- C Single Core, Solid Aluminium Conductor Rs.10200/- D Single Core, Stranded Aluminium ConductorRs.10200/- Sheathed Cable: A Single Core, Plain Copper Conductor Rs. 17550/- B Single Core, Tinned Copper Conductor Rs.17850/- C Single Core, Solid Aluminium ConductorRs.17250/- D Single Core, Stranded Aluminium Conductor Rs.17250/- For category 02 Unsheathed Cable: A Single Core, Plain Copper Conductor ?12150/- B Single Core, Tinned Copper Conductor ?12450/- C Single Core, Solid Aluminium Conductor ?11850/- D Single Core, Stranded Aluminium Conductor ?11850/- Sheathed Cable: A Single Core, Plain Copper Conductor ?18900/- B Single Core, Tinned Copper Conductor ?19200/- C Single Core, Solid Aluminium Conductor ?18600/- D Single Core, Stranded Aluminium Conductor ?18600/- For FR cables Unsheathed Cable: A Single Core, Plain Copper Conductor ?12600/- B Single Core, Tinned Copper Conductor ?12900/- C Single Core, Solid Aluminium Conductor ?12300/- D Single Core, Stranded Aluminium Conductor ?12300/- Sheathed Cable: A Single Core, Plain Copper Conductor ?19650/- B Single Core, Tinned Copper Conductor ?19950/- C Single Core, Solid Aluminium Conductor ?19350/- D Single Core, Stranded Aluminium Conductor ?19350/- For FR-LSH cables Unsheathed Cable A Single Core, Plain Copper Conductor ?13950/- B Single Core, Tinned Copper Conductor ?14250/- C Single Core, Solid Aluminium Conductor ?13650/- D Single Core, Stranded Aluminium Conductor ?13650/- Sheathed Cable: A Single Core, Plain Copper Conductor ?20820/- B Single Core, Tinned Copper Conductor ?21120/- C Single Core, Solid Aluminium Conductor ?20520/- D Single Core, Stranded Aluminium Conductor ?20520/- Material testing charges as per relevant referred Iss (For each of the above category). For multi core cable: for each additional core, the changes of single core unsheathed cable as per material (copper & aluminum) and as per construction of conductor (solid or standard, tinned or plain) shall be added
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (Annealing test (for copper)) |
- |
|
|
|
4.1 (Tensile test (for Al)-Before Stranding) |
- |
|
|
|
4.1 (Tensile test (for Al)- After Stranding) |
- |
|
|
|
4.1 (Wrapping test (for Al)) |
- |
|
|
|
4.2 (Conductor resistance test) |
- |
|
|
|
9 (Overall dimensions) |
- |
|
|
|
9.1 (Ovality) |
- |
|
|
|
Table 1 iii) c) 1) (Tensile strength (Without ageing)) |
- |
|
|
|
Table 1 iii) c) 1) (Elongation (Without ageing)) |
- |
|
|
|
Table 1 iii) c) 3) (Tensile strength (After ageing)) |
- |
|
|
|
Table 1 iii) c) 3) (Elongation (After ageing)) |
- |
|
|
|
Table 1 iii) d) 1) (Sheath -Tensile strength (Without ageing)) |
- |
|
|
|
Table 1 iii) d) 1) (Sheath- Elongation (Without ageing)) |
- |
|
|
|
Table 1 iii) d) 3) (Sheath- Tensile strength (After ageing)) |
- |
|
|
|
Table 1 iii) d) 3) (Sheath- Elongation (After ageing)) |
- |
|
|
|
Table 1 iii) c) 3) (Elongation (After ageing)) |
- |
|
|
|
Table 1 iii) d) 3) (Sheath- Elongation (After ageing)) |
- |
|
|
|
Table 1 iii) c) 2) (Loss of mass- Insulation ) |
- |
|
|
|
Table 1 iii) d) 2) (Loss of mass- Sheath ) |
- |
|
|
|
Table 1 iii) c) 7) (Thermal stability- Insulation ) |
- |
|
|
|
Table 1 iii) d) 7) (Thermal stability- Sheath ) |
- |
|
|
|
10.5 (Oxygen index) |
- |
|
|
|
10.7 (Temperature index) |
- |
|
|
|
10.5 (Oxygen index) |
- |
|
|
|
10.7 (Temperature index) |
- |
|
|
|
10.8 (Smoke density rating) |
- |
|
|
|
10.1 (HV (water immersion)) |
- |
|
|
|
10.1 (HV (water immersion)) |
- |
|
|
|
10.1 (HV (water immersion)) |
- |
|
|
|
10.2 (HV (room temperature)) |
- |
|
|
|
table 1 e) 3) (Volume Resistivity - Room temp ) |
- |
|
|
|
table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
|
|
|
table 1 e) 3) (IR constant- Room temp ) |
- |
|
|
|
table 1 e) 3) (IR constant- max. Temp) |
- |
|
|
|
10.4 (Flammability test-Burning after flame removal) |
- |
|
|
|
10.4 (Flammability test- Unaffected portion) |
- |
|
|
|
10.9 (Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
|
|
|
5.3 (Thickness of Insulation) |
- |
|
|
|
8.3 (Thickness of Sheath) |
- |
|
|
|
table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
|
|
|
table 1 e) 3) (IR constant- Room temp ) |
- |
|
|
|
table 1 e) 3) (IR constant- max. Temp) |
- |
|
|
|
Table 1 iii) c) 8) (Cold bend for insulation) |
- |
|
|
|
Table 1 iii) c) 9) (Cold impact for insulation) |
- |
|
|
|
Table 1 iii) d) 8) (Cold bend for sheath) |
- |
|
|
|
Table 1 iii) d) 9) (Cold impact for sheath) |
- |
|
|
|
10.6 (Halogen evolution) |
- |
|
|
|
Table 1 iii) c) 4) (Shrinkage-Insulation) |
- |
|
|
|
Table 1 iii) c) 4) (Cracks Observed) |
- |
|
|
|
Table 1 iii) d) 4) (Shrinkage- Sheath ) |
- |
|
|
|
Table 1 iii) d) 4) (Cracks Observed) |
- |
|
|
|
Table 1 iii) c) 5) (Heat shock-Insulation ) |
- |
|
|
|
Table 1 iii) d) 5) (Heat shock-Sheath ) |
- |
|
|
|
Table 1 iii) c) 6) (Hot deformation - Indentation depth- Insulation) |
- |
|
|
|
Table 1 iii) d) 6) (Hot deformation -Indentation depth - Sheath ) |
- |
|
|
|
(Cl.16.1)
(Cl.19.1) (Conductor- Diameter ) |
- |
|
|
|
10.9 (Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
|
|
|
11 (Identification) |
- |
|
|
|
11.1 (Durability) |
- |
|
|
|
11.2 (Legibility) |
- |
|
|
|
13 (Cable code) |
- |
|
|
|
4.1 (Conductor - Material) |
- |
|
|
|
4.1 (Conductor - Material) |
- |
|
|
|
4.4 (Joints in Conductor) |
- |
|
|
|
4.4 (Joints in Conductor) |
- |
|
|
|
5.1 (Insulation) |
- |
|
|
|
6.1 (Filler) |
- |
|
|
|
6.2 (Filler) |
- |
|
|
|
7 (Binder Tape) |
- |
|
|
|
8.1 (Sheath Material ) |
- |
|
|
|
12 (CONSTRUCTION Core Identification) |
- |
|
|
|
(Cl. 18.1.3)
(Cl. 19.1.4)
(Cl. 20.1.3)
(Cl. 21.1.3)
(Cl. 22.1.3) (Assembly of cores ) |
- |
|
|
|
(Cl.16.1)
(Cl.19.1) (Conductor) |
- |
|
|
|
(Cl.16.1)
(Cl.19.1) (Conductor) |
- |
|
|
|
(Cl.16.1)
(Cl.19.1) (Conductor) |
- |
|
|
|
(Cl.6.1 of IS 8130:2013) (Solid Conductor (Class 1)) |
- |
|
|
|
(Cl.6.1 of IS 8130:2013) (Solid Conductor (Class 1)) |
- |
|
|
|
(Cl.6.1.3 of IS 8130:2013) (Solid Conductor (Class 1)) |
- |
|
|
|
(Cl.6.1.3 of IS 8130:2013) (Stranded circular non compacted conductors (Class-2)) |
- |
|
|
|
(Cl.6.1.3 of IS 8130:2013) (Stranded circular non compacted conductors (Class-2)) |
- |
|
|
|
(Cl.6.1.3 of IS 8130:2013) (Stranded compacted circular conductors and shaped conductors (Class 2)) |
- |
|
|
|
(Cl.6.1.3 of IS 8130:2013) (Stranded circular non compacted conductors(Class-2)) |
- |
|
|
|
(Cl.6.1.3 of IS 8130:2013) ( Flexible Conductors (Classes 5)) |
- |
|
|
|
(Cl.6.1.3 of IS 8130:2013) (Flexible Conductors (Classes 5)) |
- |
|
|
|
5.2 (Application ) |
- |
|
|
|
Table 1 iii) d) 3) (Sheath- TS variation) |
- |
|
|
|
Table 1 iii) d) 3) (Sheath- Elongation variation) |
- |
|
|
|
Table 1 iii) c) 3) (TS variation) |
- |
|
|
|
Table 1 iii) c) 3) (Elongation variation) |
- |
|
|
|
|
- |
- Test Facility is complete |
11900 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 1786 (2008) |
High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 9.4 (Load In Other Direction From Bend) |
- |
|
|
|
Cl 7.2 (Weight) |
- |
|
|
|
Cl 5 (Deformations and Surface Characteristics) |
- |
|
|
|
Cl 6.1 (Length, Width & Thickness) |
- |
|
|
|
Cl.9.4 & Cl. 9.4.1 (Rebend test) |
- |
|
|
|
Cl. 9.3, Table 4 (Bend Test ) |
- |
|
|
|
Cl. 8.1 Table 3 (Elongation, percentage) |
- |
|
|
|
Cl. 8.1 Table 3 (TS/YS ratio) |
- |
|
|
|
Cl. 8.1 Table 3 (Tensile Strength (TS)) |
- |
|
|
|
Cl. 8.1 Table 3 (Yield Stress (YS)) |
- |
|
|
|
Cl. 5 (Cl. 5 - Mean projected area of transverse ribs (1/3 of Ar)) |
- |
|
|
|
Cl. 5 (Cl.5 Mean area of ribs/unit length (Ar), ) |
- |
|
|
|
Clause 4.2 Note 2, Amendment 1 & 3 (Nb+V+B+Ti) |
- |
|
|
|
Clause 4.2 Note 3, Amendment 1 & 3 (Cr+Cu+Ni+Mo+P) |
- |
|
|
|
Clause 4.2, Amendment 3 Note 4 ("In order to ascertain whether sufficient quantities of nitrogen binding elements are present, following formula may be used, where all elements are in ppm.
(N−120)< (Al free/10)+((Ti+V)/7)+(Nb/14)") |
- |
|
|
|
4.2 (Boron (B)) |
- |
|
|
|
4.2 (Niobium (Nb)) |
- |
|
|
|
4.1 (Carbon %) |
- |
|
|
|
4.1 (Manganese %) |
- |
|
|
|
4.1 (Phosphorus %) |
- |
|
|
|
4.1 (Silicon %) |
- |
|
|
|
4.1 (Sulphur %) |
- |
|
|
|
4.1 ( Copper %) |
- |
|
|
|
4.1 ( Aluminium %) |
- |
|
|
|
4.1 ( Nitrogen%) |
- |
|
|
|
4.1 ( Nb) |
- |
|
|
|
4.1 (V) |
- |
|
|
|
4.1 ( Ti) |
- |
|
|
|
4.1 (Cr) |
- |
|
|
|
4.1 (Mo) |
- |
|
|
|
4.1 (Ni) |
- |
|
|
|
4.1 (CE) |
- |
|
|
|
4.1 (Sulphur and phosphorous) |
- |
|
|
|
|
- |
- " 1 mtr x3pcS. Chemical facility is available.
Excluding EXCEPT Pullout TEST, Bend and Rebend, 0.2 percent proof stress/ yield stress, Total elongation at maximum force, bar size restricted upto 20 mm for TENSILE TEST |
11901 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 2347 (2017) |
Domestic pressure cooker - Specification (Sixth Revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.3 (Operating Test for Pressure Regulating Device) |
- |
|
|
|
8.4 (Test for Safety Pressure Relief Device) |
- |
|
|
|
8.5 (Bursting Pressure Test) |
- |
|
|
|
8.2 (Proof Pressure Test) |
- |
|
|
|
8.1 (Air Pressure Test) |
- |
|
|
|
4.1 (Capacity) |
- |
|
|
|
4.1 (Capacity ) |
- |
|
|
|
8.2 (Proof Pressure Test) |
- |
|
|
|
8.5 (Bursting Pressure Test) |
- |
|
|
|
8.1 (Air Pressure Test) |
- |
|
|
|
8.6.1 (Tests for Removal of Lid under Pressure For Outer Lid Cooker) |
- |
|
|
|
8.6.2 (Tests for Removal of Lid under Pressure For inner Lid Cooker) |
- |
|
|
|
7.1 (WORKMANSHIP AND FINISH) |
- |
|
|
|
7.2 (WORKMANSHIP AND FINISH) |
- |
|
|
|
7.3 (WORKMANSHIP AND FINISH) |
- |
|
|
|
6.4.1.1 (Handles and Knobs) |
- |
|
|
|
6.4.1 (Handles and Knobs) |
- |
|
|
|
6.1 (Pressure Regulating Device) |
- |
|
|
|
6.1.1 (Pressure Regulating Device) |
- |
|
|
|
6.1.2 (Pressure Regulating Device) |
- |
|
|
|
6.1.3 (Pressure Regulating Device) |
- |
|
|
|
6.1.4 (Pressure Regulating Device) |
- |
|
|
|
6.1.5 (Pressure Regulating Device) |
- |
|
|
|
6.2 (Safety Relief Device) |
- |
|
|
|
6.2.1 (Safety Relief Device) |
- |
|
|
|
6.2.2 (Safety Relief Device) |
- |
|
|
|
|
- |
- " 1 No
Excluding Excl Temp. Responsive Pressure Relief Device, Chromium over nickel plating, External Coating, Internal Coating and Chemical tests |
11902 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 2062 (2011) |
Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) |
For all grades except for the tests mentioned in remarks |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 10.3 (UTM) |
- |
|
|
|
Cl 11.3 (Press) |
- |
|
|
|
Cl 12 (Sudden Load Applied) |
- |
|
|
|
Cl 15 (Length, Width & Thickness) |
- |
|
|
|
Cl 15 (Length, Width & Thickness) |
- |
|
|
|
Cl 15 (Length, Width & Thickness) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E650, SILICON) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E250, CARBON) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E250, SULPHUR) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E250, PHOSPHURS) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E250 ,MANGANESE) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E250, NITROGEN) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E250, SILICON) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E250, CARBON +EQUIVELENT ) |
- |
|
|
|
Cl 7 (Workmanship) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E650, ALUMINIUM) |
- |
|
|
|
Clause 8, Table 1, Note 5 (Titanium) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E300, NITROGEN) |
- |
|
|
|
14.2 (Grain Size) |
- |
|
|
|
14.2 (Inclusion) |
- |
|
|
|
Clause 11.3 (Bend Test) |
- |
|
|
|
|
- |
- Mech - Facility not available for NDT tests ; for impact test prepared pieces to be sent; Prepared test piece to be sent for Y groove crackability test.
Chem- Facility not available for Microalloys & Al. Type of Killed material, Carbon Equivalent & Nitrogen content to be indicated in case the same are to be tested. |
11903 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 12818 (2010) |
Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) |
All sizes/types |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B (Mean Outer Diameter of Pipe) |
- |
|
|
|
7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B (Outer Diameter at any point ) |
- |
|
|
|
7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B (Mean Outer Diameter over Connection) |
- |
|
|
|
7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B (Wall thickness) |
- |
|
|
|
7.2 and Table 5, 6 & 7
Fig 1B (Mean Outer Diameter of Pipe, Min) |
- |
|
|
|
7.2 and Table 5, 6 & 7
Fig 1B (Mean Outer Diameter of Pipe , Max) |
- |
|
|
|
7.2 and Table 5, 6 & 7
Fig 1B (Outer Diameter at any point , Min) |
- |
|
|
|
7.2 and Table 5, 6 & 7
Fig 1B (Outer Diameter at any point, Max) |
- |
|
|
|
7.2 and Table 5, 6 & 7
Fig 1B (Mean Outer Diameter over Connection) |
- |
|
|
|
7.2 and Table 5, 6 & 7
Fig 1B (Wall thickness, Min) |
- |
|
|
|
7.2 and Table 5, 6 & 7
Fig 1B (Wall thickness, Max) |
- |
|
|
|
7.4 Table 8 & 9
Fig 1 (Effective length, l2) |
- |
|
|
|
7.4 Table 8 & 9
Fig 1 (Segmental length, l3) |
- |
|
|
|
8.1 to 8.3 and Table 11 &12
Fig 3A & 4A (THREADING OF SCREEN ANDCASING PIPES.
IS 554.) |
- |
|
|
|
8.4 (Sealing rings - Hardness) |
- |
|
|
|
9.3 (Density
IS 12235 (Part 14)) |
- |
|
|
|
9.4 and Table 14 (Resistance to External Blows at 0 ?C
IS 12235 (Part 9)) |
- |
|
|
|
9.5 (Tensile Strength
IS 12235(Part 13)) |
- |
|
|
|
9.6 (Vicat Softening Temperature
IS 12235 (Part 2).) |
- |
|
|
|
9.1 ( Visual Appearance) |
- |
|
|
|
7.4 Table 8 & 9
Fig 1 (Segmental length, l3) |
- |
|
|
|
Cl 9.7 (Effect on Water Lead (first extraction)) |
- |
|
|
|
Cl 9.7 (Effect on Water Lead (third extraction)) |
- |
|
|
|
Cl 9.7 (Effect on Water Dialkyl tin C4 and higher homologues(measuredas tin )(third extraction )) |
- |
|
|
|
Cl 9.7 (Effect on Water Cadmium (mean of first extraction, second extraction and third extraction)) |
- |
|
|
|
Cl 9.7 (Effect on Water Mercury (mean of first extraction, second extraction and third extraction)) |
- |
|
|
|
|
- |
- Chemical: All except Effect on Water which is for Pipes above 60 mm Nominal dia and except for the requirement of 'Other Toxic Substances such a di-n-octyl Tin -s-s bis iso-octyl mercapto acetate' and 'butyl stearate'; Mech- All except HST. |
11904 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 4985 (2000) |
Unplasticized pvc pipes for potable water supplies - Specification (Third Revision) |
All sizes/varieties |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1.1.1 (DIMENSIONS-PIPE-Mean O.D. Variation) |
- |
|
|
|
7.1.1.2 (DIMENSIONS-PIPE-O.D. at any Point (Minimum)) |
- |
|
|
|
7.1.1.2 (DIMENSIONS-PIPE-O.D. at any Point (Maximum)) |
- |
|
|
|
7.1.2.1 (DIMENSIONS-PIPE-Thickness(Minimum)) |
- |
|
|
|
7.1.2.1 (DIMENSIONS-PIPE-Thickness(Maximum)) |
- |
|
|
|
7.1.2.1 (DIMENSIONS-PIPE-Average Thickness) |
- |
|
|
|
7.2.1 (DIMENSIONS-Socket) |
- |
|
|
|
10.2 (PHYSICAL AND CHEMICAL CHARACTERISTICS-Opacity) |
- |
|
|
|
10.4 (PHYSICAL AND CHEMICAL CHARACTERISTICS- Reversion Test) |
- |
|
|
|
10.5 (PHYSICAL AND CHEMICAL CHARACTERISTICS- Vicat Softening Temperature) |
- |
|
|
|
10.6 (PHYSICAL AND CHEMICAL CHARACTERISTICS- Density) |
- |
|
|
|
11.2 (Resistance to External Blows at 0°C) |
- |
|
|
|
10.1 (PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
|
|
|
10.1.1 (PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
|
|
|
7.2.1.1-Table 3 (DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Maximum)) |
- |
|
|
|
Clause 10.7 (Sulphated Ash Content) |
- |
|
|
|
10.3 ("Effect on Water
a) Lead (first extraction) ") |
- |
|
|
|
10.3 (b) Lead (Third extraction)) |
- |
|
|
|
10.3 (c) Dialkyl Tin C4 & higher homologues measured as Tin (Third extraction)) |
- |
|
|
|
10.3 (d) Cadmium (All three extracts)) |
- |
|
|
|
10.3 (e) Mercury (All three extracts)) |
- |
|
|
|
|
- |
- Chemical: All except Effect on Water which is for Pipes above 60 mm Nominal dia and except for the requirement of 'Other Toxic Substances such a di-n-octyl Tin -s-s bis iso-octyl mercapto acetate' and 'butyl stearate'; Mech- All except HST. |
11905 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 2347 (2017) |
Domestic pressure cooker - Specification (Sixth Revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (Capacity ) |
- |
|
|
|
5.2 (Safety Relief Device) |
- |
|
|
|
6.1.1 (Pressure Regulating Device) |
- |
|
|
|
8.1 (Air Pressure Test) |
- |
|
|
|
8.2 (Proof Pressure Test) |
- |
|
|
|
8.3 (Operating Test for Pressure Regulating Device) |
- |
|
|
|
8.4 (Test for Safety Pressure Relief Device) |
- |
|
|
|
8.5 (Bursting Pressure Test) |
- |
|
|
|
8.6.1 (Tests for Removal of Lid under Pressure For Outer Lid Cooker) |
- |
|
|
|
|
- |
- Facility not available for Cl 8.6(test for Outer lid type),8.7,8.8,8.9,8.10,7.4, For Chemical tests, see status of IS for individual components (IS 21/6911/5522). |
11906 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 398 : Part 2 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
Up to 100 sq mm |
- View breakup
(I) For galvanized steel core only (consisting of 7 steel strands)- Rs.2850.00, (II) For galvanized steel reinforced stranded conductors with nominal aluminium area upto and including 100mm2-(a) For single steel wire core (1 steel + 6 Aluminium)- Rs. 1950.00 (b) For 7 wire core (7 steel + 6 Aluminium) - Rs. 4000.00, (III) For galvanized steel reinforced stranded conductors with nominal aluminium area more than 100mm2 (excluding special tests as per Cl. 13.9, 13.10 & 13.11)-(a) For stranded conductors with 37 strands-Rs.7900/-, (b) For stranded conductors with 49 strands-Rs.10000/-, (c) For stranded conductors with 61 strands-Rs.11100/-,
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
10 (elec) (Stranding) |
- |
|
|
|
10 (elec) (Stranding) |
- |
|
|
|
10 (elec) (Stranding) |
- |
|
|
|
13.4.2 (elec) (Ductility by Elongation Test before stranding) |
- |
|
|
|
13.4.2 (elec) (Ductility by Elongation Test after stranding) |
- |
|
|
|
13.6 (elec) (Resistance test-Aluminium wire before Stranding) |
- |
|
|
|
13.6 (elec) (Resistance test-Aluminium wire after stranding) |
- |
|
|
|
13.9 (elec) (Surface condition test) |
- |
|
|
|
13.10 (elec) (Ultimate breaking load) |
- |
|
|
|
13.11 (elec) (Stress-strain test) |
- |
|
|
|
13.8 Table-4 (elec) (Lay Ratio- Steel Core (6 Wire Layer)) |
- |
|
|
|
13.8 Table-4 (elec) (Lay Ratio- Steel Core (6 Wire Layer)) |
- |
|
|
|
13.8 Table-4 (elec) (Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
|
|
|
13.8 Table-4 (elec) (Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
|
|
|
13.8 Table-4 (elec) (Lay Ratio- Aluminium Wire Outermost Layer) |
- |
|
|
|
13.7.2 (elec) (Uniformity of Zinc coating) |
- |
|
|
|
13.7.2 (elec) (Mass of Zinc coating) |
- |
|
|
|
13.5.2 (elec) (Wrapping Test Galvanized Steel Wires After Stranding) |
- |
|
|
|
13.5.2 (elec) (Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
|
|
|
13.5.1 (elec) (Wrapping Test Aluminium Wires After Stranding) |
- |
|
|
|
13.5.1 (elec) (Wrapping Test Aluminium Wires Before Stranding) |
- |
|
|
|
13.4.1 (elec) (Ductility by Torsion Test after stranding) |
- |
|
|
|
13.4.1 (elec) (Ductility by Torsion Test before stranding) |
- |
|
|
|
13.3 Table 2 (elec) (Breaking Load of Steel Wires After Stranding) |
- |
|
|
|
13.3 Table 2 (elec) (Breaking Load of Steel Wires Before Stranding) |
- |
|
|
|
13.3 Table 1 (elec) (Breaking Load of Aluminium Wires After Stranding) |
- |
|
|
|
13.3 Table 1 (elec) (Breaking Load of Aluminium Wires Before Stranding) |
- |
|
|
|
8.1.1 & 13.2 Table 2 (elec) (Diameter of Steel Wires After Stranding) |
- |
|
|
|
8.1.1 & 13.2 Table-1 (elec) (Diameter of Aluminium Wires After Stranding) |
- |
|
|
|
8.1.1 & 13.2 Table 2 (elec) (Diameter of Steel Wires Before Stranding) |
- |
|
|
|
8.1.1 & 13.2 Table-1 (elec) (Diameter of Aluminium Wires Before Stranding) |
- |
|
|
|
|
- |
- Test facility not available for Cl. 13.9, 13.10 and 13.11 for size 100 sq.mm and above. |
11907 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 3854 (1997) |
Switches for domestic and similar purposes - Specification (Second Revision) |
- |
- View breakup
6A Screw type terminals-Rs.4900/-, 6A Screwless type terminals-Rs.5850/-,10A Screw type terminals-Rs.5050/-, 10A Screwless type terminals-Rs.6400/-, 16A Screw type terminals-Rs.5850/-,16A Screwless type terminals-Rs.7900/-, 20A-Rs.5250/-, 25A-Rs.5900/-, 32A-Rs.6250/-, 40A-Rs.6550/-, 63A-Rs.6200/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
10 (Protection against Electric Shock) |
- |
|
|
|
11.1 (Provision for earthing) |
- |
|
|
|
12.2.3 (Mechanical strength of terminals) |
- |
|
|
|
12.2.4 (Resistance to corrosion) |
- |
|
|
|
12.2.5 (Undue damage to conductor) |
- |
|
|
|
12.2.7 (Insertion of conductor) |
- |
|
|
|
12.2.11 (Distance between screw and conductor) |
- |
|
|
|
12.3.2 (Screwless terminals) |
- |
|
|
|
12.3.4 (Material of terminals) |
- |
|
|
|
12.3.11 (vi) Electrical & Thermal Stresses [Cl 12.3.11]) |
- |
|
|
|
12.3.12 (vii) Deflection Stresses [Cl. 12.3.12]) |
- |
|
|
|
13.15 (q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
|
|
|
15.1 (Resistance to Ageing, to Harmful Ingress of water and to Humidity [Cl. 15]: Resistance to Ageing, [Cl. 15.1]) |
- |
|
|
|
15.2 (b)Resistance to Harmful ingress of water [Cl. 15.2]) |
- |
|
|
|
15.3 (c) Resistance to Humidity [Cl. 15.3]) |
- |
|
|
|
16.1 (Insulation resistance [Cl. 16.1]) |
- |
|
|
|
16.2 ( Electric Strength [Cl. 16.2]) |
- |
|
|
|
17 (Temperature- rise [Cl. 17]) |
- |
|
|
|
19 (Normal Operation [Cl. 19] a) General & Operation) |
- |
|
|
|
19 (b) Electric Strength) |
- |
|
|
|
19 (c)Temperature-rise ) |
- |
|
|
|
19.2 (Normal Operation (For AX type Switches) [Cl. 19.2]) |
- |
|
|
|
20 (Mechanical Strength Test [Cl. 20]) |
- |
|
|
|
21 (Resistance to Heat [Cl.21]) |
- |
|
|
|
22 (Screw, Current Carrying Part And Connection [Cl.22]) |
- |
|
|
|
23.2 (Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
|
|
|
24.1.1 (Resistance to Abnormal Heat & Fire [Cl.24.1] [Glow Wire Test] [Cl.24.1.1]) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
8.9 (Marking) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
7 (Classification) |
- |
|
|
|
7 (Classification) |
- |
|
|
|
7 (Classification) |
- |
|
|
|
7 (Classification) |
- |
|
|
|
7 (Classification) |
- |
|
|
|
7 (Classification) |
- |
|
|
|
7 (Classification) |
- |
|
|
|
12 (Terminals) |
- |
|
|
|
12.2.1 (Terminals) |
- |
|
|
|
12 (Terminals) |
- |
|
|
|
12.2.2 (Connection of conductor) |
- |
|
|
|
12.2.7 (Insertion of conductor) |
- |
|
|
|
12.2.9 (Locking against accidental loosening) |
- |
|
|
|
12.3.2 (Screwless terminals) |
- |
|
|
|
12.3.3 (Connectin of conductor) |
- |
|
|
|
12.3.4 (Material of terminals) |
- |
|
|
|
12.3.5 (Clamping) |
- |
|
|
|
12.3.7 (v) Interconnection of conductors [Cl. 12.3.7]) |
- |
|
|
|
13.1 (a) Insulating lining, barriers and the like [Cl 13.1]) |
- |
|
|
|
13.2 (b) Construction of switch [Cl 13.2]) |
- |
|
|
|
13.2 (i) Installation Test) |
- |
|
|
|
13.3 (c) Covers,cover plates and actuating members [Cl 13.3]) |
- |
|
|
|
13.4 (d) Ordinary switches [Cl 13.4]) |
- |
|
|
|
13.5 (e) Rotary switches [Cl 13.5]) |
- |
|
|
|
13.6 (f) Screws and other means [Cl 13.6]) |
- |
|
|
|
12.3.7 (v) Interconnection of conductors [Cl. 12.3.7]) |
- |
|
|
|
13.8 (h) Assessories combined with switches [Cl. 13.8]) |
- |
|
|
|
13.9 (j) Switches other than ordinary switches [Cl. 13.9]) |
- |
|
|
|
13.9 (j) Switches other than ordinary switches [Cl. 13.9]) |
- |
|
|
|
13.1 (k) Switches to be installed in a box [Cl. 13.10]) |
- |
|
|
|
13.12, 13.13, 13.14 (m) Inlet opening [Cl. 13.12.13.13 & 13.14]) |
- |
|
|
|
13.15 (q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
|
|
|
13.15 (q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
|
|
|
14 (Mechanism [Cl. 14]) |
- |
|
|
|
14.4 (Mechanism) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
14.4 (Mechanism) |
- |
|
|
|
14.3 (d)Test for arcing and sparking [Cl 14.3]) |
- |
|
|
|
21 (Resistance to Heat [Cl.21]) |
- |
|
|
|
21 (Resistance to Heat [Cl.21]) |
- |
|
|
|
23 (Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
|
|
|
24.2 (Resistance to tracking [For Switch other than ordinary] [Cl.24.2]) |
- |
|
|
|
19.2 (Normal Operation (For AX type Switches) [Cl. 19.2]) |
- |
|
|
|
22.1 (i) Screw & Nuts [Cl.22.1]) |
- |
|
|
|
22.3 (iii) Electrical Connections [Cl.22.3]) |
- |
|
|
|
22.4 (ii) Screw & rivets [Cl . 22.4]) |
- |
|
|
|
22.5 (iv) Current carrying part [Cl.22.5]) |
- |
|
|
|
18 (Marking and breaking Capacity[Cl. 18]) |
- |
|
|
|
7 (Classification) |
- |
|
|
|
7 (Classification) |
- |
|
|
|
6.1 (Ratings) |
- |
|
|
|
6.2 (Ratings) |
- |
|
|
|
25 (Resistance to Rusting) |
- |
|
|
|
|
- |
- Complete TF is available for variety upto and including 20A.
For above 20A rating (32A, 63A), the following facilities are not available:
1. Cl 17 Temperature rise
2. Cl 18, Making and breaking Capacity
3. Cl 19 Normal Operation" |
11908 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 398 : Part 2 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
Complete up to 100 sqmm |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1.1 & 13.2 Table 2 (elec) (Diameter of Steel Wires After Stranding) |
- |
|
|
|
10 (elec) (Stranding) |
- |
|
|
|
13.3 Table 2 (elec) (Breaking Load of Steel Wires Before Stranding) |
- |
|
|
|
13.3 Table 2 (elec) (Breaking Load of Steel Wires After Stranding) |
- |
|
|
|
13.3 Table 1 (elec) (Breaking Load of Aluminium Wires After Stranding) |
- |
|
|
|
13.4.1 (elec) (Ductility by Torsion Test before stranding) |
- |
|
|
|
13.4.1 (elec) (Ductility by Torsion Test after stranding) |
- |
|
|
|
13.8 Table-4 (elec) (Lay Ratio- Steel Core (6 Wire Layer)) |
- |
|
|
|
13.8 Table-4 (elec) (Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
|
|
|
13.8 Table-4 (elec) (Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
|
|
|
13.8 Table-4 (elec) (Lay Ratio- Aluminium Wire Outermost Layer) |
- |
|
|
|
13.5.2 (elec) (Wrapping Test Galvanized Steel Wires After Stranding) |
- |
|
|
|
13.5.1 (elec) (Wrapping Test Aluminium Wires After Stranding) |
- |
|
|
|
13.4.2 (elec) (Ductility by Elongation Test after stranding) |
- |
|
|
|
13.7.2 (elec) (Uniformity of Zinc coating) |
- |
|
|
|
13.7.2 (elec) (Mass of Zinc coating) |
- |
|
|
|
13.9 (elec) (Surface condition test) |
- |
|
|
|
13.10 (elec) (Ultimate breaking load) |
- |
|
|
|
13.6 (elec) (Resistance test-Aluminium wire after stranding) |
- |
|
|
|
10 (elec) (Stranding) |
- |
|
|
|
10 (elec) (Stranding) |
- |
|
|
|
13.6 (elec) (Resistance test-Aluminium wire before Stranding) |
- |
|
|
|
8.1.1 & 13.2 Table-1 (elec) (Diameter of Aluminium Wires After Stranding) |
- |
|
|
|
8.1.1 & 13.2 Table 2 (elec) (Diameter of Steel Wires After Stranding) |
- |
|
|
|
8.1.1 & 13.2 Table-1 (mech) (Diameter of Aluminium Wires Before Stranding) |
- |
|
|
|
10 (elec) (Stranding) |
- |
|
|
|
13.3 Table 1 (mech) (Breaking Load of Aluminium Wires After Stranding) |
- |
|
|
|
13.6 (elec) (Resistance test-Aluminium wire after stranding) |
- |
|
|
|
13.3 Table 1 (mech) (Breaking Load of Aluminium Wires Before Stranding) |
- |
|
|
|
8.1.1 & 13.2 Table-1 (mech) (Diameter of Aluminium Wires Before Stranding) |
- |
|
|
|
8.2.2 (Calculated resistance) |
- |
|
|
|
|
- |
- All tests are available up to and including 100 sq.mm. For Above 100 sq.mm. facility not available for Stress-Strain Test, Surface Condition, Ultimate B/L on stranded conductor. |
11909 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 1786 (2008) |
High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) |
For all grades except for the tests mentioned in remarks |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 5 (Cl.5 Mean area of ribs/unit length (Ar), ) |
- |
|
|
|
Cl. 5 (Cl. 5 - Mean projected area of transverse ribs (1/3 of Ar)) |
- |
|
|
|
Cl 7.2 (Weight) |
- |
|
|
|
Cl. 8.1 Table 3 (Yield Stress (YS)) |
- |
|
|
|
Cl. 8.1 Table 3 (Tensile Strength (TS)) |
- |
|
|
|
Cl. 8.1 Table 3 (TS/YS ratio) |
- |
|
|
|
Cl. 8.1 Table 3 (Elongation, percentage) |
- |
|
|
|
4.1 (Sulphur and phosphorous) |
- |
|
|
|
Clause - 4.2 & 4.2.1 (Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 CARBON ) |
- |
|
|
|
Clause - 4.2 & 4.2.1 (Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 SULPHUR) |
- |
|
|
|
Clause - 4.2 & 4.2.1 (Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 PHOSPHURS) |
- |
|
|
|
Clause - 4.2 & 4.2.1 (Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 NITROGEN) |
- |
|
|
|
Clause - 4.2 & 4.2.1 (Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 MANGANESE) |
- |
|
|
|
Clause - 4.2 & 4.2.1 (Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 SULPHUR+PHOSPHUR) |
- |
|
|
|
Clause - 4.2 & 4.2.1 (Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 CARBON +EQUIVELENT ) |
- |
|
|
|
Cl. 8.1 Table 3 (Elongation, percentage) |
- |
|
|
|
Cl. 9.3, Table 4 (Bend Test ) |
- |
|
|
|
Cl.9.4 & Cl. 9.4.1 (Rebend test) |
- |
|
|
|
8.18.1 Table 3 (Total elongation at maximum force) |
- |
|
|
|
|
- |
- Mech - Facility not available for pull out test, total elongation at maximum force.
Chem- Facility not available for Micro-alloying elements. Declarations regarding type of 'Killed' material, Micro-alloys/low-alloys, Nitrogen content or any other parameter as per Note under clause 4.2 to be provided. |
11910 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
Complete for Cat 01(up to 400sq.mm)Except optional test |
- View breakup
Rs.16650/- for single core unarmoured cable, Rs.22500/- for two core, unarmoured cable, Rs.26700/- for two core armoured cable (Excluding addl. Type test for cables with improved fire performance.) For multi core cables, extra charges @ 35 % for each additional core shall be levied. Material testing charges as per relevant referred ISs Testing charges for Additional Type Tests for Improved Fire Performance Tests: Rs. 7100/- for category C1 Rs. 11700/- for category C2
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1 (MATERIALS : CONDUCTOR) |
- |
|
|
|
5.2 (MATERIALS : FILLER AND INNER SHEATH) |
- |
|
|
|
5.1 (MATERIALS : FILLER AND INNER SHEATH) |
- |
|
|
|
6.1 (MATERIALS : ARMGURING) |
- |
|
|
|
8.1 (CONSTRUCTION : CONDUCTOR) |
- |
|
|
|
8.2 (CONSTRUCTION : CONDUCTOR) |
- |
|
|
|
9.2 (INSULATION : Thickness of Insulation) |
- |
|
|
|
9.3 (INSULATION :Tolerance on Thickness of Insulation) |
- |
|
|
|
9.4 (INSULATION : Application of Insulation) |
- |
|
|
|
10.1 (CORE IDENTIFICATION) |
- |
|
|
|
10.3 (CORE IDENTIFICATION) |
- |
|
|
|
10.2 (CORE IDENTIFICATION) |
- |
|
|
|
11.1 (LAYING UP OF CORES) |
- |
|
|
|
12.1 (INNER SHEATH) |
- |
|
|
|
12.2 (INNER SHEATH) |
- |
|
|
|
12.3 (INNER SHEATH :Thickness of Inner Sheath) |
- |
|
|
|
12.3.1 (INNER SHEATH :Thickness of Inner Sheath) |
- |
|
|
|
13.1.1 (ARMOURING : Application) |
- |
|
|
|
13.1.2 (Armouring: Coverage ) |
- |
|
|
|
13.1.3 (ARMOURING : Direction of lay ) |
- |
|
|
|
13.1.4 (ARMOURING : Application) |
- |
|
|
|
13.2 (ARMOURING : Type of Armour) |
- |
|
|
|
13.2.1 (ARMOURING : Type of Armour) |
- |
|
|
|
13.3 (Armouring : Dimensions -Wire Diameter) |
- |
|
|
|
13.3 (Armouring : Dimensions -Formed wire ) |
- |
|
|
|
13.4 (ARMOURING : Joints) |
- |
|
|
|
13.5.1 (ARMOURING : Resistance) |
- |
|
|
|
13.5.2 (ARMOURING : Resistance) |
- |
|
|
|
13.6 a) (ARMOURING: Tensile Strength) |
- |
|
|
|
13.6 b) (ARMOURING: Elongation ) |
- |
|
|
|
13.6 c) (ARMOURING: Torsion Test (For round wire ) ) |
- |
|
|
|
13.6 d) (ARMOURING: Winding Test(For formed wire)) |
- |
|
|
|
13.6 e) (ARMOURING: Uniformity of zinc coating) |
- |
|
|
|
13.6 f) (ARMOURING: Mass of zinc coating ) |
- |
|
|
|
13.6 g) (ARMOURING: Resistivity) |
- |
|
|
|
14.1 (OUTER SHEATH) |
- |
|
|
|
14.2 (OUTER SHEATH) |
- |
|
|
|
14.3 (OUTER SHEATH : Colour ) |
- |
|
|
|
14.4.2 (Thickness of Outer Sheath : Armoured Cables) |
- |
|
|
|
15.1 a) 1) (Tests on conductor : Annealing test ( for copper )) |
- |
|
|
|
15.1 a) 2) (Tensile test (for aluminium) - Before stranding ) |
- |
|
|
|
15.1 a) 2) (Tensile test (for aluminium) - After stranding ) |
- |
|
|
|
15.1 a) 3) (Tests on conductor : Wrapping test ( for aluminium )) |
- |
|
|
|
15.1 a) 4) (Tests on conductor : Conductor resistance test) |
- |
|
|
|
15.1 a) 4) (Resistance test - Neutral conductor ) |
- |
|
|
|
15.1 d)1) (Phyaical tests for insulation : Tensile Test) |
- |
|
|
|
15.1 d)1) (Phyaical tests for insulation : Elongation ) |
- |
|
|
|
15.1 d)1) (Physical tests for sheath : Elongation ) |
- |
|
|
|
15.1 d)1) (Physical tests for sheath : Tensile stregth ) |
- |
|
|
|
15.1 d)1) (Physical tests for sheath : Elongation ) |
- |
|
|
|
15.1 d)1) (Physical tests for sheath : Tensile stregth ) |
- |
|
|
|
15.1 d)1) (Physical tests for sheath : Elongation ) |
- |
|
|
|
15.1 d)2) (Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
|
|
|
15.1 d)2) (Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
|
|
|
15.1 d)2) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
|
|
|
15.1 d)2) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
|
|
|
15.1 d)2) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
|
|
|
15.1 d)2) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
|
|
|
15.1 d)2) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
|
|
|
15.1 d)2) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
|
|
|
15.1 d)3) (Phyaical tests for insulation : Shrinkage ) |
- |
|
|
|
15.1 d)3) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
|
|
|
15.1 d)3) (Phyaical tests for Sheath : Shrinkage ) |
- |
|
|
|
15.1 d)3) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
|
|
|
15.1 d)4) (Hot deformation : Insulation ) |
- |
|
|
|
15.1 d)4) (Hot deformation : Sheath ) |
- |
|
|
|
15.1 d)5) ( Loss of mass in air oven- Insulation ) |
- |
|
|
|
15.1 d)5) ( Loss of mass in air oven- sheath ) |
- |
|
|
|
15.1 d)6) (Heat shock test- Insulation ) |
- |
|
|
|
15.1 d)6) (Heat shock test- sheath ) |
- |
|
|
|
15.1 d)7) (Thermal stability- insulation ) |
- |
|
|
|
15.1 d)7) (Thermal stability- Sheath ) |
- |
|
|
|
15.1.e (Insulation resistance Test- Volume Resistivity At Room temperature) |
- |
|
|
|
15.1.e (Insulation resistance Test- Volume Resistivity At Maximum rated temperature temperature) |
- |
|
|
|
15.1.e (Insulation resistance Test- Insulation resistance constant At Room temperature) |
- |
|
|
|
15.1.e (Insulation resistance Test- Insulation resistance At Maximum rated temperature temperature) |
- |
|
|
|
16.2 (DETAILS OF TESTS : High Voltage Test at Room Temperature) |
- |
|
|
|
16.3.2 (High Voltage Test ( Water Immersion Test ) : d.c. Test) |
- |
|
|
|
16.3.1 (High Voltage Test ( Water Immersion Test ) : a.c. Test) |
- |
|
|
|
17.1 (IDENTIFICATION : Manufacturer’s Identification) |
- |
|
|
|
17.2 (IDENTIFICATION : Cable Identification) |
- |
|
|
|
17.2.1 (IDENTIFICATION : Cable Identification) |
- |
|
|
|
17.3 (IDENTIFICATION : Cable Code) |
- |
|
|
|
15.1 e) (Insulation resistance test : Volume Resistivity ) |
- |
|
|
|
15.1 e) (Insulation resistance test : IR Constant ) |
- |
|
|
|
15.1 d)3) (Phyaical tests for insulation : Shrinkage ) |
- |
|
|
|
15.1 d)3) (Phyaical tests for Sheath : Shrinkage ) |
- |
|
|
|
15.1 d)4) (Hot deformation : Insulation ) |
- |
|
|
|
15.1 d)4) (Hot deformation : Sheath ) |
- |
|
|
|
13.3 (Armouring : Dimensions -Formed wire ) |
- |
|
|
|
14.4.1 (Thickness of Outer Sheath : Unarmowed Cables) |
- |
|
|
|
16.4 (Flammability Test) |
- |
|
|
|
8.1 (CONSTRUCTION : CONDUCTOR) |
- |
|
|
|
3.1 (MATERIALS : CONDUCTOR) |
- |
|
|
|
8.2 (CONSTRUCTION : CONDUCTOR) |
- |
|
|
|
9.3 (Minimum Thickness of Reduce core insulation) |
- |
|
|
|
9.2 (Thickness of Reduce core insulation) |
- |
|
|
|
3.1 Table 2
IS 8130 (Number of wires in the conductor) |
- |
|
|
|
|
- |
- For Category-01 and upto 400 sq mm: all tests are available except additional tests. For cat. C1 and C2 : Except oxygen Index,Temperature index, Flame Retardance, Smoke Density, Halogen acid Gas Evolution |