| 11851 |
SKC COMPLIANCE LAB PRIVATE LIMITED, MAHADEVPURA
| 6170406
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
120000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.7(Markings and instructions) |
- |
3500 |
|
10% discount for BIS |
| 1.6(Power interface .) |
- |
5000 |
|
10% discount for BIS |
| 2.1(Protection from electric shock and energy hazards) |
- |
7000 |
|
10% discount for BIS |
| 2.2(SELV circuits) |
- |
3000 |
|
10% discount for BIS |
| 2.3(TNV circuits) |
- |
3000 |
|
10% discount for BIS |
| 2.4(Limited current circuits) |
- |
1000 |
|
10% discount for BIS |
| 2.5(Limited power sources .) |
- |
1500 |
|
10% discount for BIS |
| 2.6(Provisions for earthing and bonding) |
- |
4500 |
|
10% discount for BIS |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
1000 |
|
10% discount for BIS |
| 2.8(Safety interlocks) |
- |
1000 |
|
10% discount for BIS |
| 2.9(Electrical insulation) |
- |
10000 |
|
10% discount for BIS |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
8000 |
|
10% discount for BIS |
| 3.1(General) |
- |
1000 |
|
10% discount for BIS |
| 3.2(Connection to a mains supply) |
- |
2000 |
|
10% discount for BIS |
| 3.3(Wiring terminals for connection of external conductors) |
- |
3000 |
|
10% discount for BIS |
| 3.5(Interconnection of equipment) |
- |
500 |
|
10% discount for BIS |
| 4.1(Stability) |
- |
2500 |
|
10% discount for BIS |
| 4.2(Mechanical strength) |
- |
8000 |
|
10% discount for BIS |
| 4.3(Design and construction) |
- |
5000 |
|
10% discount for BIS |
| 4.4(Protection against hazardous moving parts) |
- |
500 |
|
10% discount for BIS |
| 4.5(Thermal requirements) |
- |
6000 |
|
10% discount for BIS |
| 4.6(Openings in enclosures) |
- |
2000 |
|
10% discount for BIS |
| 4.7(Resistance to fire) |
- |
2500 |
|
10% discount for BIS |
| 5.1(Touch current and protective conductor curren) |
- |
2500 |
|
10% discount for BIS |
| 5.2(Electric strength) |
- |
3500 |
|
10% discount for BIS |
| 5.3(Abnormal operating and fault conditions) |
- |
4500 |
|
10% discount for BIS |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
500 |
|
10% discount for BIS |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
500 |
|
10% discount for BIS |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
500 |
|
10% discount for BIS |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
500 |
|
10% discount for BIS |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
500 |
|
10% discount for BIS |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
500 |
|
10% discount for BIS |
| 3.4(Disconnection from the mains supply) |
- |
1000 |
|
10% discount for BIS |
| 7.1(General) |
- |
500 |
|
10% discount for BIS |
| 1.5(Components) |
- |
5000 |
|
10% discount for BIS |
| 1.5(Components) |
- |
5000 |
|
10% discount for BIS |
| 2.8.2/2.8.5(Interlock switches) |
- |
1000 |
|
10% discount for BIS |
| 2.8.7(Switches and Relay) |
- |
1000 |
|
10% discount for BIS |
| 2.10.4.2(Material Group and Comparative Tracking Index) |
- |
3000 |
|
10% discount for BIS |
| 2.10.5.3(Insulating Compound as Solid Insulation) |
- |
500 |
|
10% discount for BIS |
| 2.10.5.4(Opto-coupler) |
- |
500 |
|
10% discount for BIS |
| 2.10.5.6(Thin sheet materials) |
- |
500 |
|
10% discount for BIS |
| 2.10.5.11(SMPS Transformer and Inductor) |
- |
500 |
|
10% discount for BIS |
| 2.10.5.12(Wires in wound components) |
- |
500 |
|
10% discount for BIS |
| 2.10.5.13(Winding wire) |
- |
500 |
|
10% discount for BIS |
| 2.10.5.14(Additional insulation in wound components) |
- |
500 |
|
10% discount for BIS |
| 2.10.6(PCB material) |
- |
500 |
|
10% discount for BIS |
| 2.10.8.2(Thermal conditioning (thermal ageing)) |
- |
500 |
|
10% discount for BIS |
| 2.10.8.4(Abrasion resistance test) |
- |
500 |
|
10% discount for BIS |
| 2.10.9(Thermal Cycling) |
- |
1000 |
|
10% discount for BIS |
| 2.10.10(Test for Pollution Degree 1 environment and for insulating compound) |
- |
500 |
|
10% discount for BIS |
| 2.10.11(Tests for semiconductor devices and for cemented joints) |
- |
500 |
|
10% discount for BIS |
| 2.10.12(Enclosed and sealed parts) |
- |
500 |
|
10% discount for BIS |
| 3.1.4(Internal wire) |
- |
500 |
|
10% discount for BIS |
| 3.2.4(Appliance inlet /connector) |
- |
500 |
|
10% discount for BIS |
| 3.2.5(Non re-wirable plug with PVC sheathed cable) |
- |
500 |
|
10% discount for BIS |
| 4.3.8(Batteries) |
- |
2500 |
|
10% discount for BIS |
| 4.3.10(Dust, powders, liquids and gases) |
- |
500 |
|
10% discount for BIS |
| 4.3.11(Containers for liquids or gases) |
- |
500 |
|
10% discount for BIS |
| 4.3.12(Flammable liquids) |
- |
500 |
|
10% discount for BIS |
| Annex A3(Hot flaming oil test) |
- |
1000 |
|
10% discount for BIS |
| Annex U(Insulating winding wires for use without interleaved insulation) |
- |
500 |
|
10% discount for BIS |
| Annex CC(Evaluation of integrated circuit (IC) current limiters) |
- |
500 |
|
10% discount for BIS |
| Annex K(Thermal Control) |
- |
500 |
|
10% discount for BIS |
| Annex Q(Voltage Dependent Resistors) |
- |
500 |
|
10% discount for BIS |
|
24 May, 2028 |
- EXCLUSIONS: Visual Display unit, video monitors of screen size restricted up to 60" EXCLUSIONS:
Cl no.: 1.5 Components (Approved component used, verified based on certificates)
Cl no. :2.8.5 Moving parts Cl no.: 2.8.7 Switches and relay Cl no.: 2.10.5.4 Semiconductor devices Cl no.:4.2.9 High Pressure Lamps (Compliance will be checked with approved test report) Cl no.: 4.3.13 Radiation Annex A. 3: Hot flaming oil test
Annex H: lonizing radiation Annex K. Thermal Controls Annex Q: Voltage dependent
Resistors (VDRs) Annex R. Examples of requirements for quality control Programmes Annex U: Insulated winding wires for use without interleaved Insulation Annex Y: Ultraviolet Light conditioning test Annex CC: Evaluation of Integrated circuits current limiters. |
| 11852 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
- |
23000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
500 |
|
10% discount offered to BIS |
| 7.0(Marking and instructions) |
- |
1000 |
|
10% discount offered to BIS |
| 8.0(Protection against access to live part test) |
- |
1000 |
|
10% discount offered to BIS |
| 10.0(Power Input and current test) |
- |
1500 |
|
10% discount offered to BIS |
| 11.0(Heating test) |
- |
2800 |
|
10% discount offered to BIS |
| 13.0(Leakage current and electric strength test) |
- |
2500 |
|
10% discount offered to BIS |
| 14.0(Transient voltages) |
- |
1400 |
|
10% discount offered to BIS |
| 15.0(Moisture Resistance) |
- |
4200 |
|
10% discount offered to BIS |
| 16.0(Leakage current and electric strength test) |
- |
2100 |
|
10% discount offered to BIS |
| 17.0(Overload protection of transformers test) |
- |
1300 |
|
10% discount offered to BIS |
| 19.0(Abnormal Operations) |
- |
2000 |
|
10% discount offered to BIS |
| 20.0(Stability and Mechanical Hazards) |
- |
1500 |
|
10% discount offered to BIS |
| 21.0(Mechanical Strength) |
- |
1800 |
|
10% discount offered to BIS |
| 22.0(Construction verification related tests) |
- |
5500 |
|
10% discount offered to BIS |
| 23.0(Internal wiring) |
- |
800 |
|
10% discount offered to BIS |
| 24.0(Components) |
- |
1300 |
|
10% discount offered to BIS |
| 25.0(Supply connections and External Flexible Cords) |
- |
1600 |
|
10% discount offered to BIS |
| 26.0(Terminal for External Conductors) |
- |
1000 |
|
10% discount offered to BIS |
| 27.0(Provision for Earthing) |
- |
2100 |
|
10% discount offered to BIS |
| 28.0(Screws and connections) |
- |
800 |
|
10% discount offered to BIS |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
2550 |
|
10% discount offered to BIS |
| 30.0(Resistance to heat and fire) |
- |
6000 |
|
10% discount offered to BIS |
| 31.0(Resistance to rusting) |
- |
2100 |
|
10% discount offered to BIS |
| 19.11.4.4(Surge immunity test) |
- |
2000 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- [0:26 pm, 24/05/2022] Aslam office: EMI/EMC tests (electrostatic Discharges,
Radiant Fields, Fast Transient burst, [0:26 pm, 24/05/2022] Aslam office: Voltage surges, Injected current, voltage dips & Interruptions, Mains signals) [cl.19.11.4.1 to Cl.19.11.4.7], Radiation,
Toxicity & Similar Hazards (cl.32), Components (Cl.24), endurance of switches (Cl.24.1.3),
endurance of automatic controls (Cl.24.1.4) |
| 11853 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 4250 (1980) |
Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
300 |
|
10% discount offered to BIS |
| 7.1(Marking- IS 302-1) |
- |
0.00 |
|
- |
| 7.2(Marking) |
- |
0 |
|
- |
| 7.4(Marking) |
- |
0 |
|
- |
| 7.5(Marking) |
- |
0 |
|
- |
| 7.6(Marking) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 9(Starting, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 10(Power Input and Current, IS 302-1) |
- |
700 |
|
10% discount offered to BIS |
| 11(Heating, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 14(Transient Over Voltages, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 15.1(Moisture Resistance, IS 302-1) |
- |
800 |
|
10% discount offered to BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 19(Abnormal Operation, IS 302-1) |
- |
700 |
|
10% discount offered to BIS |
| 20(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 21(Mechanical Strength, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 22.1(Construction, IS 302-1) |
- |
100 |
|
10% discount offered to BIS |
| 22.2(Construction) |
- |
100 |
|
10% discount offered to BIS |
| 22.3(Construction) |
- |
100 |
|
10% discount offered to BIS |
| 22.4(Construction) |
- |
100 |
|
10% discount offered to BIS |
| 22.5(Construction) |
- |
100 |
|
10% discount offered to BIS |
| 22.6(Construction) |
- |
100 |
|
10% discount offered to BIS |
| 22.8(Construction) |
- |
100 |
|
10% discount offered to BIS |
| 22.9(Construction) |
- |
100 |
|
10% discount offered to BIS |
| 22.1(Construction) |
- |
100 |
|
10% discount offered to BIS |
| 23(Internal Wiring, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 24.1(Components, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
700 |
|
10% discount offered to BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 27(Provision for Earthing, IS 302-1) |
- |
700 |
|
10% discount offered to BIS |
| 28(Screws & Connections, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 29(Clearances and Distances through Insulation, IS 302-1) |
- |
700 |
|
10% discount offered to BIS |
| 30(Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
| 34.2(Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
1000 |
|
10% discount offered to BIS |
| 34.3(Whisking egg whites ) |
- |
1000 |
|
10% discount offered to BIS |
| 34.4(IDLI batter-Grinding of black gram) |
- |
1000 |
|
10% discount offered to BIS |
| 34.5.1 (a)(Operational test for juicers ) |
- |
500 |
|
10% discount offered to BIS |
| 34.5.1 (b)(Operational test for juicers ) |
- |
500 |
|
10% discount offered to BIS |
| 34.5.2(Operational test for juicers ) |
- |
300 |
|
10% discount offered to BIS |
| 35(Temperature withstand test for bowl) |
- |
500 |
|
10% discount offered to BIS |
| 36(Test for controls ) |
- |
1000 |
|
10% discount offered to BIS |
| 37(Strength of Assembly ) |
- |
1000 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- EMI/EMC tests (Electrostatic discharges, radiant fields, fast transient bursts, voltage Surges, injected current, voltage dip and interruption, mains signals) (Cl.19.11.4.1 to
19.11.4.7), Radio Intreference Suppression test(Cl.14)' |
| 11854 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 8978 (1992) |
Specification for electric instantaneous water heaters (Second Revision) |
- |
19000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.10 of IS 8978 : 1992(Finish) |
- |
300 |
|
10% discount for BIS |
| Cl.11 of IS 8978 : 1992(Operation of flow switch) |
- |
1700 |
|
10% discount for BIS |
| Cl.12 of IS 8978 : 1992(Endurance) |
- |
1700 |
|
10% discount for BIS |
| Cl.6 of IS 302-2-35:2017(Classification) |
- |
600 |
|
10% discount for BIS |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
600 |
|
10% discount for BIS |
| Cl.8 of IS 302-2-35:2017(Protection Against Access To Live Parts) |
- |
800 |
|
10% discount for BIS |
| Cl.10 of IS 302-2- 35:2011(Power Input & Current ) |
- |
900 |
|
10% discount for BIS |
| Cl.11 of 302-2-35:2017(Heating) |
- |
800 |
|
10% discount for BIS |
| Cl.13 of IS 302-2-35:2017(Leakage Current & Electrical Strength at Operating Temperature ) |
- |
400 |
|
10% discount for BIS |
| Cl.14 of IS 302-2-35:2017(Transient Over Voltages ) |
- |
1100 |
|
10% discount for BIS |
| Cl.15 of IS 302-2-35-2011(Moisture Resistance ) |
- |
1500 |
|
10% discount for BIS |
| Cl.16 of IS 302-2-35:2011(Leakage Current and Electric Strength) |
- |
1200 |
|
10% discount for BIS |
| Cl.17 IS 302-2-35:2017(Overload Protection of Transformers & Associated circuits ) |
- |
700 |
|
10% discount for BIS |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation) |
- |
1200 |
|
10% discount for BIS |
| Cl.20 of IS 302-2-35-2011(Stability & Mechanical Hazards
) |
- |
600 |
|
10% discount for BIS |
| Cl.21.1 of IS 302-2-35-2011(Mechanical strength) |
- |
400 |
|
10% discount for BIS |
| Cl. 21.2 of IS 302-1:2008(Mechanical strength) |
- |
400 |
|
10% discount for BIS |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
400 |
|
10% discount for BIS |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
500 |
|
10% discount for BIS |
| Cl.24 of IS 302-2-35:2017(Component
) |
- |
600 |
|
10% discount for BIS |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
600 |
|
10% discount for BIS |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
400 |
|
10% discount for BIS |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
600 |
|
10% discount for BIS |
| Cl.28 of IS 302-2-35:2017(Screws and Connections
) |
- |
600 |
|
10% discount for BIS |
| Cl.29 of IS 302-2-35:2017(Clearances, Creepage Distances and Solid Insulation) |
- |
500 |
|
10% discount for BIS |
| Cl.30 of IS 302-2-35: 2011(Resistance to Heat and Fire) |
- |
1100 |
|
10% discount for BIS |
| Cl.31 of IS 302-2-35: 2011(Resistance to Rusting
) |
- |
700 |
|
10% discount for BIS |
|
22 May, 2028 |
- Restricted to steel tanks only and with rated pressure upto 1.2MPA EMI/EMC tests (Electrostatic discharges, radiant fields, fast transient bursts, voltage surges, injected current, voltage dip and
interruption, mains signals) (Cl.19.11.4.1 to 19.11.4.7) |
| 11855 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 2082 (2018) |
Stationary storage type electric water heaters - Specification (Fifth Revision) |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.15 of IS 2082:2018(Verification of the Rated Capacity) |
- |
900 |
|
10% discount offered to BIS |
| Cl.16 of IS 2082:2018(Standing Loss per 24 Hours) |
- |
4000 |
|
10% discount offered to BIS |
| Cl.17 of IS 2082:2018(Hot Water Output) |
- |
1000 |
|
10% discount offered to BIS |
| Cl.18 of IS 2082:2018( Reheating Time) |
- |
1200 |
|
10% discount offered to BIS |
| Cl.19 of IS 2082:2018(Mixing Factor) |
- |
800 |
|
10% discount offered to BIS |
| Cl.20 of IS 2082:2018(Deviation of Dial Calibration) |
- |
900 |
|
10% discount offered to BIS |
| Cl.21 of IS 2082:2018(Cyclic Temperature Variation) |
- |
1000 |
|
10% discount offered to BIS |
| Cl.22 of IS 2082:2018(Finish) |
- |
500 |
|
10% discount offered to BIS |
| 6(Classification ) |
- |
600 |
|
10% discount offered to BIS |
| 7(Marking) |
- |
600 |
|
10% discount offered to BIS |
| (Cl.8 of IS 302-2-21:2011)(Protection Against Access to Live Parts) |
- |
800 |
|
10% discount offered to BIS |
| (Cl.10 of IS 302-2-21: 2011)(Power Input & Current) |
- |
1200 |
|
10% discount offered to BIS |
| (Cl.11 of 302-2-21:2011)(Heating) |
- |
800 |
|
10% discount offered to BIS |
| (Cl.13 of IS 302-2-21:2011)(Leakage Current ) |
- |
400 |
|
10% discount offered to BIS |
| (Cl.13 of IS 302-2-21:2011)(Electrical Strength at Operating Temperature) |
- |
400 |
|
10% discount offered to BIS |
| (Cl.14ofIS302-2-21:2011)(Transient Over Voltages) |
- |
1100 |
|
10% discount offered to BIS |
| (Cl.15 of IS 302-2-21-2011)(Moisture Resistance) |
- |
1400 |
|
10% discount offered to BIS |
| (Cl.17 of IS 302-2-21:2011)(Overload protection of transformers & associated circuits) |
- |
900 |
|
10% discount offered to BIS |
| (Cl.19 of IS 302-2-21:2011)(Abnormal Operation) |
- |
1500 |
|
10% discount offered to BIS |
| (Cl.20 of IS 302-2-21:2011)(Stability & Mechanical Hazards) |
- |
600 |
|
10% discount offered to BIS |
| (Cl.21ofIS302-2-21:2011)(Mechanical strength) |
- |
400 |
|
10% discount offered to BIS |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
400 |
|
10% discount offered to BIS |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
700 |
|
10% discount offered to BIS |
| (Cl.24ofIS302-221:2011)(Component) |
- |
500 |
|
10% discount offered to BIS |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
600 |
|
10% discount offered to BIS |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
400 |
|
10% discount offered to BIS |
| (Cl.27 of IS 302-2-21:2011)(Provision for Earthing) |
- |
600 |
|
10% discount offered to BIS |
| (Cl.28 of IS 302-2-21:2011)(Screws & Connections) |
- |
600 |
|
10% discount offered to BIS |
| (Cl.29ofIS302-2-21:2011)(Clearances, Creepage Distances and Solid Insulation) |
- |
500 |
|
10% discount offered to BIS |
| (Cl.30 of IS 302-2-21:2011)(Resistance to Heat & Fire) |
- |
1200 |
|
10% discount offered to BIS |
| (Cl.31 of IS 302-2-21:2011)(Resistance to Rusting) |
- |
800 |
|
10% discount offered to BIS |
| Cl.16 of IS 302-2-21-2018(Leakage current and Electric strength (After humidity): Leakage current ) |
- |
600 |
|
10% discount offered to BIS |
| Cl.16 of IS 302-2-21-2018(Leakage current and Electric strength (After humidity): Electric Strentgh ) |
- |
600 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- - |
| 11856 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 302 : Part 2 : Sec 35 (2017) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 35 electric instantaneous water heaters (Second Revision) |
- |
16613 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6
IS 302-2-35(Classification) |
- |
600 |
|
10% discount offered to BIS |
| Cl. 7
IS 302-2-35(Marking and Instruction) |
- |
600 |
|
10% discount offered to BIS |
| Cl. 8
IS 302-2-35(Protection against access to live parts) |
- |
800 |
|
10% discount offered to BIS |
| Cl. 10
IS 302-2-35(Power Input and Current ) |
- |
900 |
|
10% discount offered to BIS |
| Cl. 11
IS 302-2-35(Heating) |
- |
800 |
|
10% discount offered to BIS |
| Cl. 13
IS 302-2-35(Leakage Current & Electric Strength at Operating Temperature) |
- |
400 |
|
10% discount offered to BIS |
| Cl. 14
IS 302-2-35(Radio and television interference suppression / Transient over voltages) |
- |
1100 |
|
10% discount offered to BIS |
| Cl. 15
IS 302-2-35(Moisture Resistance Test ) |
- |
1400 |
|
10% discount offered to BIS |
| Cl. 16
IS 302-2-35(Leakage Current & Electric Strength at Operating Temperature (After Humidity Treatment)) |
- |
1200 |
|
10% discount offered to BIS |
| Cl. 17
IS 302-2-35(Overload Protection of Transformers and Associated Circuit) |
- |
700 |
|
10% discount offered to BIS |
| Cl. 19
IS 302-2-35(Abnormal Operation ) |
- |
1200 |
|
10% discount offered to BIS |
| Cl. 20
IS 302-2-35(Stability & Mechanical Hazards) |
- |
600 |
|
10% discount offered to BIS |
| Cl. 21
IS 302-2-35(Mechanical strength) |
- |
400 |
|
10% discount offered to BIS |
| Cl. 22
IS 302-2-35(Construction ) |
- |
400 |
|
10% discount offered to BIS |
| Cl. 23
IS 302-2-35(Internal Wiring) |
- |
500 |
|
10% discount offered to BIS |
| Cl. 24
IS 302-2-35(Components) |
- |
600 |
|
10% discount offered to BIS |
| Cl. 25
IS 302-2-35(Supply Connection & External Flexible Cords) |
- |
600 |
|
10% discount offered to BIS |
| Cl. 26
IS 302-2-35(Terminals for External conductors ) |
- |
400 |
|
10% discount offered to BIS |
| Cl. 27
IS 302-2-35(Provision for Earthing ) |
- |
600 |
|
10% discount offered to BIS |
| Cl. 28
IS 302-2-35(Screws & Connections) |
- |
600 |
|
10% discount offered to BIS |
| Cl. 29
IS 302-2-35(Clearances, Creepage Distances & Solid insulation ) |
- |
500 |
|
10% discount offered to BIS |
| Cl. 30
IS 302-2-35(Resistance to Heat Fire & Tracking ) |
- |
1100 |
|
10% discount offered to BIS |
| Cl.31(Verification) |
- |
700 |
|
10% discount offered to BIS |
| Cl. 31
IS 302-2-35(Resistance to Rusting) |
- |
700 |
|
10% discount offered to BIS |
| 19.11.4.4(Surge immunity test) |
- |
2000 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Restricted to rated pressure upto 1.2MPA. EMI/EMC tests (electrostatic Discharges,
Radiant Fields, Fast Transient burst, Voltage surges, Injected current, voltage
dips & Interruptions, Mains signals) [cl.19.11.4.1 to Cl.19.11.4.7], Components
(Capacitors for radio interference suppression, isolating transformer,
coupler) (Cl.24.1.1, 24.1.2, 24.1) Note: Copper purity declared by manufacturer. |
| 11857 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 302 : Part 2 : Sec 26 (2014) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 26 clocks (First Revision) |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
500 |
|
10% discount offered to BIS |
| 7(Marking and instructions) |
- |
600 |
|
10% discount offered to BIS |
| 8(Protection against live parts) |
- |
1000 |
|
10% discount offered to BIS |
| 10(POWER INPUT AND CURRENT) |
- |
1800 |
|
10% discount offered to BIS |
| 11(HEATING) |
- |
2000 |
|
10% discount offered to BIS |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1100 |
|
10% discount offered to BIS |
| 14(TRANSIENT OVERVOLTAGES) |
- |
1500 |
|
10% discount offered to BIS |
| 15(MOISTURE RESISTANCE) |
- |
2000 |
|
10% discount offered to BIS |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1500 |
|
10% discount offered to BIS |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1100 |
|
10% discount offered to BIS |
| 19(ABNORMAL OPERATION) |
- |
1500 |
|
10% discount offered to BIS |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
500 |
|
10% discount offered to BIS |
| 21(MECHANICAL STRENGTH) |
- |
1500 |
|
10% discount offered to BIS |
| 22(CONSTRUCTION) |
- |
2000 |
|
10% discount offered to BIS |
| 23(INTERNAL WIRING) |
- |
1100 |
|
10% discount offered to BIS |
| 24(COMPONENTS) |
- |
800 |
|
10% discount offered to BIS |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
1500 |
|
10% discount offered to BIS |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
500 |
|
10% discount offered to BIS |
| 27(PROVISION FOR EARTHING) |
- |
1000 |
|
10% discount offered to BIS |
| 28(SCREWS AND CONNECTIONS) |
- |
900 |
|
10% discount offered to BIS |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
1400 |
|
10% discount offered to BIS |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
1800 |
|
10% discount offered to BIS |
| 31(RESISTANCE TO RUSTING) |
- |
1800 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Cl. 19.11.4.1 to 19.11.4.4 EMI/EMC, Cl. 24 Components, Radiation, Toxicity & Similar
Hazards (cl.32) |
| 11858 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 302 : Part 2 : Sec 25 (2014) |
Safety of household and similar electrical appliances: Part 2 Particular requirements: Section 25 Microwave ovens |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
500 |
|
10% discount offered to BIS |
| 7(Marking and instructions) |
- |
1000 |
|
10% discount offered to BIS |
| 8(Protection against live parts) |
- |
900 |
|
10% discount offered to BIS |
| 10(POWER INPUT AND CURRENT) |
- |
1500 |
|
10% discount offered to BIS |
| 11(HEATING) |
- |
2500 |
|
10% discount offered to BIS |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1500 |
|
10% discount offered to BIS |
| 14(IMPULSE VOLTAGE TEST) |
- |
1800 |
|
10% discount offered to BIS |
| 15(HUMIDITY TREATMENT TEST) |
- |
3500 |
|
10% discount offered to BIS |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
2200 |
|
10% discount offered to BIS |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1600 |
|
10% discount offered to BIS |
| 18(ENDURANCE) |
- |
1800 |
|
10% discount offered to BIS |
| 19(ABNORMAL OPERATION) |
- |
2400 |
|
10% discount offered to BIS |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
1200 |
|
10% discount offered to BIS |
| 21(MECHANICAL STRENGTH) |
- |
1500 |
|
10% discount offered to BIS |
| 22(CONSTRUCTION) |
- |
4000 |
|
10% discount offered to BIS |
| 23(INTERNAL WIRING) |
- |
1000 |
|
10% discount offered to BIS |
| 24(COMPONENTS) |
- |
800 |
|
10% discount offered to BIS |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
1100 |
|
10% discount offered to BIS |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1100 |
|
10% discount offered to BIS |
| 27(PROVISION FOR EARTHING) |
- |
1800 |
|
10% discount offered to BIS |
| 28(SCREWS AND CONNECTIONS) |
- |
1100 |
|
10% discount offered to BIS |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
1200 |
|
10% discount offered to BIS |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
4500 |
|
10% discount offered to BIS |
| 31(RESISTANCE TO RUSTING) |
- |
1800 |
|
10% discount offered to BIS |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
2500 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Cl.19.11.4 EMI/EMC -- Cl.24 Components ( Magnetron, HV
transformer capacitor diode, Capacitor and RC units RF Suppression X-Y capacitor, PCB
Material, Inductor SMPS Transformer, MOV/VDR, Relays, Power cord, Thermal
Cut-out / Thermostat Appliance connector Inlet Door Interlock Switches, IP category,
Enclosure insulation material, Bridging resistor)Cyclic(Sodium Chloride solution) |
| 11859 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 302 : Part 2 : Sec 21 (2018) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 21 stationary storage type electric water heaters (Second Revision) |
- |
16500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
600 |
|
10% discount offered to BIS |
| 7.0(Marking and Instructions) |
- |
600 |
|
10% discount offered to BIS |
| 8.0(Protection against access to live parts) |
- |
800 |
|
10% discount offered to BIS |
| 10.0(Input and Current) |
- |
1200 |
|
10% discount offered to BIS |
| 11.0(Heating) |
- |
800 |
|
10% discount offered to BIS |
| 13.0(Leakage Current and electric strength at operating temperature) |
- |
400 |
|
10% discount offered to BIS |
| 14.0(Transient Overvoltage) |
- |
1100 |
|
10% discount offered to BIS |
| 15.0(Moisture resistance) |
- |
1400 |
|
10% discount offered to BIS |
| 16.0(Leakage current and Electric strength (After Humidity (Environmental) Treatment)) |
- |
1200 |
|
10% discount offered to BIS |
| 17.0(Overload Protection of transformer and associated circuit) |
- |
900 |
|
10% discount offered to BIS |
| 19.0(Abnormal Operation) |
- |
1500 |
|
10% discount offered to BIS |
| 20.0(Stability and mechanical hazards) |
- |
600 |
|
10% discount offered to BIS |
| 21.0(Mechanical Strength) |
- |
400 |
|
10% discount offered to BIS |
| 22.0(Construction) |
- |
400 |
|
10% discount offered to BIS |
| 23.0(Internal Wiring) |
- |
700 |
|
10% discount offered to BIS |
| 25.0(Supply Connection and External Flexible Cords) |
- |
600 |
|
10% discount offered to BIS |
| 26.0(Terminals for external conductors) |
- |
400 |
|
10% discount offered to BIS |
| 27.0(Provision For Earthing) |
- |
600 |
|
10% discount offered to BIS |
| 28.0(Screws and Connections) |
- |
600 |
|
10% discount offered to BIS |
| 29.0(Creepage Distances and Clearances) |
- |
500 |
|
10% discount offered to BIS |
| 30.0(Resistance To Heat and Fire) |
- |
1200 |
|
10% discount offered to BIS |
| 31.0(Resistance To Rusting) |
- |
800 |
|
10% discount offered to BIS |
| 24(Components) |
- |
500 |
|
10% discount offered to BIS |
| 19.11.4.4(Surge immunity test) |
- |
2000 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Restricted to rated pressure upto 1.2MPA. EMI/EMC tests (electrostatic Discharges,
Radiant Fields, Fast Transient burst, Voltage surges, Injected current, voltage
dips & Interruptions, Mains signals) [cl.19.11.4.1 to Cl.19.11.4.7], Radiation, Toxicity & Similar Hazards (cl.32), Components (C1.24) Note: Copper purity declared by manufacturer. |
| 11860 |
Bharat Test House Pvt Ltd 1474 Sonipat Haryana
| 9135626
| IS/IEC 61730 : PART 1 (2004) |
Photovoltaic (PV) Module Safety Qualification Part 1 Requirements for Construction |
- |
468500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Application classes) |
- |
0 |
|
- |
| 4(Construction requirements) |
- |
0 |
|
- |
| 5(Polymeric materials) |
- |
250000 |
|
- |
| 6(Internal wiring and current-carrying parts) |
- |
7500 |
|
- |
| 7(Connections) |
- |
75000 |
|
- |
| 8(Bonding and grounding) |
- |
7500 |
|
- |
| 9(Creepage and clearance distances) |
- |
17500 |
|
- |
| 10(Field wiring compartments with covers) |
- |
110000 |
|
- |
| 11(Marking) |
- |
1000 |
|
- |
| 12() |
- |
0 |
|
- |
| 3(Application classes) |
- |
0 |
|
5% discount for BIS |
| 4(Construction requirements) |
- |
0 |
|
5% discount for BIS |
| 5(Polymeric materials) |
- |
250000 |
|
5% discount for BIS |
| 6(Internal wiring and current-carrying parts) |
- |
7500 |
|
5% discount for BIS |
| 7(Connections) |
- |
75000 |
|
5% discount for BIS |
| 8(Bonding and grounding) |
- |
7500 |
|
5% discount for BIS |
| 9(Creepage and clearance distances) |
- |
17500 |
|
5% discount for BIS |
| 10(Field wiring compartments with covers) |
- |
110000 |
|
5% discount for BIS |
| 11(Marking) |
- |
1000 |
|
5% discount for BIS |
| 12() |
- |
0 |
|
5% discount for BIS |
|
19 Mar, 2026 |
- - |
| 11861 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 368 (2014) |
Electric immersion water heaters - Specification (Fifth Revision) |
- |
19000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 of IS 302-‐2-‐201:2008(Classification) |
- |
500 |
|
10% discount offered to BIS |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
600 |
|
10% discount offered to BIS |
| Cl.8 of IS 302‐2-201: 2008(Protection Against Access to Live Parts) |
- |
1000 |
|
10% discount offered to BIS |
| Cl.10 of IS 302‐2‐201:2008(Power Input and Current ) |
- |
1200 |
|
10% discount offered to BIS |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1100 |
|
10% discount offered to BIS |
| Cl. 12 of IS 368:2014(Operation under overload conditions of appliances with heating elements) |
- |
1000 |
|
10% discount offered to BIS |
| Cl.13 of IS 302-2-201: 2008(Leakage Current & Electric Strength at Operating Temperature) |
- |
600 |
|
10% discount offered to BIS |
| Cl.14 of IS 302‐2-201:2008(Transient Over Voltages ) |
- |
900 |
|
10% discount offered to BIS |
| Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
1200 |
|
10% discount offered to BIS |
| Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
1100 |
|
10% discount offered to BIS |
| Cl.17 of IS 302‐2-201: 2008(Overload Protection of Transformers & Associated Circuits) |
- |
900 |
|
10% discount offered to BIS |
| Cl.18 of IS 368:2014(Endurance) |
- |
1100 |
|
10% discount offered to BIS |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1500 |
|
10% discount offered to BIS |
| Cl.20 of IS 302-2-201: 2008(Stability & Mechanical Hazards) |
- |
500 |
|
10% discount offered to BIS |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
600 |
|
10% discount offered to BIS |
| Cl.22 of IS 302-2-201: 2008(Construction) |
- |
400 |
|
10% discount offered to BIS |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
500 |
|
10% discount offered to BIS |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
500 |
|
10% discount offered to BIS |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
600 |
|
10% discount offered to BIS |
| Cl.26 of IS 302-2-201: 2008(Terminals for External Conductors) |
- |
400 |
|
10% discount offered to BIS |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
700 |
|
10% discount offered to BIS |
| Cl.28 of IS 302-2-201: 2008(Screws & Connections ) |
- |
400 |
|
10% discount offered to BIS |
| Cl.29 of IS 302-2‐201:2008(Clearances, Creepage Distances and Solid Insulation ) |
- |
600 |
|
10% discount offered to BIS |
| Cl.30 of IS 302-2‐201:2008(Resistance to Heat and Fire ) |
- |
1200 |
|
10% discount offered to BIS |
| Cl.31 of IS 302-2-201:2008(Resistance of Rusting ) |
- |
700 |
|
10% discount offered to BIS |
| 19.11.4.4(Surge immunity test) |
- |
2000 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Restricted Upto 5KW EMI/EMC tests (Electrostatic discharges, radiant fields, fast transient bursts, voltage
surges, injected current, voltage dip and interruption, mains signals) (Cl.19.11.4.1 to
19.11.4.7), Components (Capacitors for radio interference suppression, isolating transformer, coupler) (Cl.24.1.1, 24.1.2, 24.1.5) |
| 11862 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 16103 : Part 1 (2012) |
Led modules for general lighting: Part 1 safety requirements |
- |
37500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
1500 |
|
10% discount offered to BIS |
| 8(Terminals) |
- |
2500 |
|
10% discount offered to BIS |
| 9(PROVISION FOR EARTHING) |
- |
2000 |
|
10% discount offered to BIS |
| 10(Protection against accidental contact with live parts) |
- |
2500 |
|
10% discount offered to BIS |
| 11(Mositure Resistance and Insulation) |
- |
8000 |
|
10% discount offered to BIS |
| 12(Electric Strength) |
- |
2000 |
|
10% discount offered to BIS |
| 13(Fault conditions) |
- |
5000 |
|
10% discount offered to BIS |
| 15(Construction) |
- |
5000 |
|
10% discount offered to BIS |
| 16(Creepage distance and clearances) |
- |
4000 |
|
10% discount offered to BIS |
| 17(Screws, current carrying parts and connections) |
- |
2500 |
|
10% discount offered to BIS |
| 18(Resistance to heat, fire and tracking) |
- |
4000 |
|
10% discount offered to BIS |
| 19(Resistance to corrosion) |
- |
2000 |
|
10% discount offered to BIS |
| 21(Heat management) |
- |
500 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Components (Cl.102) |
| 11863 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
- |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking and instructions) |
- |
1000.00 |
|
10% discount offered to BIS |
| 6(Hazardous radiations) |
- |
0.00 |
|
- |
| 7(Heating under normal operating conditions) |
- |
8000 |
|
10% discount offered to BIS |
| 8(Constructional requirements with regard to the protection against electric shock) |
- |
5000 |
|
10% discount offered to BIS |
| 9(Electric shock hazard under normal operating conditions) |
- |
7000 |
|
10% discount offered to BIS |
| 10(Insulation requirements) |
- |
5000 |
|
10% discount offered to BIS |
| 11(Fault conditions) |
- |
8000 |
|
10% discount offered to BIS |
| 12(Mechanical strength) |
- |
3000 |
|
10% discount offered to BIS |
| 13(CLEARANCES and CREEPAGE DISTANCES) |
- |
5000 |
|
10% discount offered to BIS |
| 15(TERMINALS) |
- |
2000 |
|
10% discount offered to BIS |
| 16(External flexible cords) |
- |
3000 |
|
10% discount offered to BIS |
| 17(Electrical connections and mechanical fixings) |
- |
2000 |
|
10% discount offered to BIS |
| 18(Mechanical strength of picture tubes and protection against the effects of implosion) |
- |
0.00 |
|
- |
| 19(Stability and mechanical hazards) |
- |
6000 |
|
10% discount offered to BIS |
| 20(Resistance to fire) |
- |
5000 |
|
10% discount offered to BIS |
| 14(Components) |
- |
1000 |
|
10% discount offered to BIS |
| Annex-A(Additional requirements for apparatus with protection against splashing water) |
- |
1500 |
|
10% discount offered to BIS |
| Annex-B(Apparatus to be connected to the TELECOMMUNICATION NETWORKS) |
- |
1200 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Ionizing radiation (Cl.6.1), Products other than with laser system class 1 (Cl. 6.2), Light a emitting (6.3), Endurance test for wound components with insulated winding wires without additional interleaved insulation (Cl.8.16), Endurance test for wound components with insulated winding wires without additional interleaved insulation (Cl.8.17), Printed boards (CL.13.5), Enclosed, enveloped or hermetically connected to the mains, clearness and creepage distanced (Cl. 13.7), Components (CL..14.0), 8 Plugs & sockets (Cl. 15.1), terminals for external flexible cords and for permanent connection to the mains supply (Cl 15.3), Mains cords sheathed type, complying with (Cl.16.1), Mechanical strength of Picture tubes & protection against the effect of implosion (Cl.18), Electrical component & mech. Parts (Cl.20.2),Resistors (Cl.14.2), Capacitors & RC units (Cl .14.3), Inductors & windings (Cl.14.4), High voltage components & assemblies (Cl.14.5), Protective devices (Cl.14.6), Thermal releases (14.6.2), Fuse & fuse holder (Cl.14.6.3), PTC thermistor (Cl.14.6.4), Switch (14.7), Batteries (Cl.14.11), Opto coupler (.14.12), Surge suppression varistors (14.13) |
| 11864 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 10322 : Part 5 : Sec 9 (2017) |
Luminaires: Part 5 particular requirements: Sec 9 rope lights |
- |
55000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 21.4(General Test Requireements) |
- |
500 |
|
10% discount offered to BIS |
| 21.5(Classification of Luminaires') |
- |
500 |
|
10% discount offered to BIS |
| 21.6(Marking) |
- |
1500 |
|
10% discount offered to BIS |
| 21.7(Construction) |
- |
10000 |
|
10% discount offered to BIS |
| 21.8(Creepage Distance and Clearances) |
- |
3000 |
|
10% discount offered to BIS |
| 21.9(Provision for earthing) |
- |
2500 |
|
10% discount offered to BIS |
| 21.10(Terminals) |
- |
2500 |
|
10% discount offered to BIS |
| 21.11(External & Internal Wiring) |
- |
5000 |
|
10% discount offered to BIS |
| 21.12(Protection against electric shock) |
- |
2500 |
|
10% discount offered to BIS |
| 21.13(Endurance Tests and Thermal Tests) |
- |
10000 |
|
10% discount offered to BIS |
| 21.14(Resistance to Dust & Moisture) |
- |
7000 |
|
10% discount offered to BIS |
| 21.15(Insulation Resistance and Electric Strength) |
- |
3000 |
|
10% discount offered to BIS |
| 21.16(Resistance to Heat , fire and tracking) |
- |
5000 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Electrical endurance (CBC) (cl.20.7.4 & Cl.6.14.2 of Annex A), Bendings
(Nonrewireable connectors) (cl.20.7.4 & Cl.6.14.3 of Annex A), Control Unit
(Cl.20.7.8 & IEC 61347-2-11) IPX8 upto 1.3m |
| 11865 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 10322 : Part 5 : Sec 7 (2017) |
Luminaires: Part 5 particular requirements: Sec 7 lighting chains (First Revision) |
- |
55000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 20.4(General Test Requireements) |
- |
500 |
|
10% discount offered to BIS |
| 20.5(Classification of Luminaires') |
- |
500 |
|
10% discount offered to BIS |
| 20.6(Marking) |
- |
1500 |
|
10% discount offered to BIS |
| 20.7(Construction) |
- |
10000 |
|
10% discount offered to BIS |
| 20.8(Creepage Distance and Clearances) |
- |
3000 |
|
10% discount offered to BIS |
| 20.9(Provision for earthing) |
- |
2500 |
|
10% discount offered to BIS |
| 20.10(Terminals) |
- |
2500 |
|
10% discount offered to BIS |
| 20.11(External & Internal Wiring) |
- |
5000 |
|
10% discount offered to BIS |
| 20.12(Protection against electric shock) |
- |
2500 |
|
10% discount offered to BIS |
| 20.13(Endurance Tests and Thermal Tests) |
- |
10000 |
|
10% discount offered to BIS |
| 20.14(Resistance to Dust & Moisture) |
- |
7000 |
|
10% discount offered to BIS |
| 20.15(Insulation Resistance and Electric Strength) |
- |
3000 |
|
10% discount offered to BIS |
| 20.16(Resistance to Heat , fire and tracking) |
- |
5000 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- UV Radiations as per C. 4.24 & Annex P of IS 10322 (Part 1):2014, Electrical endurance (CBC) (cl.20.7.4 & Cl.6.14.2 of Annex A), Bendings (Nonrewireable connectors) (cl.20.7.4 & Cl.6.14.3 of Annex A), Control
Unit (Cl.20.7.8 & IEC 61347-2-11) IPX8 upto 1.3m |
| 11866 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 10322 : Part 5 : Sec 6 (2013) |
Luminaires: Part 5 particular requirements: Sec 6 handlamps |
- |
55000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
500 |
|
10% discount offered to BIS |
| 5(Classification of Luminaires') |
- |
500 |
|
10% discount offered to BIS |
| 7.0(Construction) |
- |
10000 |
|
10% discount offered to BIS |
| 8.0(Creepage Distance and Clearances) |
- |
3000 |
|
10% discount offered to BIS |
| 9.0(Provision for earthing) |
- |
2500 |
|
10% discount offered to BIS |
| 10.0(Terminals) |
- |
2500 |
|
10% discount offered to BIS |
| 11.0(External & Internal Wiring) |
- |
5000 |
|
10% discount offered to BIS |
| 12.0(Protection against electric shock) |
- |
2500 |
|
10% discount offered to BIS |
| 13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
10% discount offered to BIS |
| 14.0(Resistance to Dust & Moisture) |
- |
7000 |
|
10% discount offered to BIS |
| 15.0(Insulation Resistance and Electric Strength) |
- |
3000 |
|
10% discount offered to BIS |
| 16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
10% discount offered to BIS |
| 6.0(Marking) |
- |
1500 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- UV Radiation for Metal halide lamps (Cl.4.24, Annex-P) IPX8 upto 1.3m |
| 11867 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 10322 : Part 5 : Sec 5 (2013) |
Luminaires: Part 5 particular requirements: Sec 5 floodlights (First Revision) |
- |
55000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
500 |
|
10% discount offered to BIS |
| 5(Classification of Luminaires') |
- |
500 |
|
10% discount offered to BIS |
| 6.0(Marking) |
- |
1500 |
|
10% discount offered to BIS |
| 7.0(Construction) |
- |
8000 |
|
10% discount offered to BIS |
| 8.0(Creepage Distance and Clearances) |
- |
3000 |
|
10% discount offered to BIS |
| 9.0(Provision for earthing) |
- |
2500 |
|
10% discount offered to BIS |
| 10.0(Terminals) |
- |
2500 |
|
10% discount offered to BIS |
| 11.0(External & Internal Wiring) |
- |
5000 |
|
10% discount offered to BIS |
| 12.0(Protection against electric shock) |
- |
2500 |
|
10% discount offered to BIS |
| 13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
10% discount offered to BIS |
| 14.0(Resistance to Dust & Moisture) |
- |
7000 |
|
10% discount offered to BIS |
| 15.0(Insulation Resistance and Electric Strength) |
- |
3000 |
|
10% discount offered to BIS |
| 16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
10% discount offered to BIS |
| 17.0(Photometric Test) |
- |
25000 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Luminaries size restricted to 1000 mm for photometric test, UV Radiations as per C. 4
.24 & Annex P of IS 10322 (Part 1):2014, Short-circuit protection as per cl.4.26 IPX8 upto 1.3m |
| 11868 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 10322 : PART 5 : SEC 3 (2012) |
Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) |
- |
55000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
500 |
|
10% discount offered to BIS |
| 5(Classification of Luminaires') |
- |
500 |
|
10% discount offered to BIS |
| 6.0(Marking) |
- |
1500 |
|
10% discount offered to BIS |
| 7.0(Construction) |
- |
8000 |
|
10% discount offered to BIS |
| 8.0(Creepage Distance and Clearances) |
- |
3000 |
|
10% discount offered to BIS |
| 9.0(Provision for earthing) |
- |
2500 |
|
10% discount offered to BIS |
| 10.0(Terminals) |
- |
2500 |
|
10% discount offered to BIS |
| 11.0(External & Internal Wiring) |
- |
5000 |
|
10% discount offered to BIS |
| 12.0(Protection against electric shock) |
- |
2500 |
|
10% discount offered to BIS |
| 13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
10% discount offered to BIS |
| 14.0(Resistance to Dust & Moisture) |
- |
7000 |
|
10% discount offered to BIS |
| 15.0(Insulation Resistance and Electric Strength) |
- |
3000 |
|
10% discount offered to BIS |
| 16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
10% discount offered to BIS |
| 17.0(Photometric Test) |
- |
25000 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Luminaries size restricted to 1000 mmfor photometric test, UV Radiations as per C. 4
.24 & Annex P of IS 10322 (Part 1):2014, Short-circuit protection as per cl.4.26 IPX8 upto 1.3m |
| 11869 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 10322 : Part 5 : Sec 2 (2012) |
Luminaires: Part 5 particular requirements: Sec 2 recessed luminaires (First Revision) |
- |
55000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
500 |
|
10% discount offered to BIS |
| 5(Classification of Luminaires') |
- |
500 |
|
10% discount offered to BIS |
| 6(Marking) |
- |
1500 |
|
10% discount offered to BIS |
| 7(Construction) |
- |
8000 |
|
10% discount offered to BIS |
| 8(Creepage Distance and Clearances) |
- |
3000 |
|
10% discount offered to BIS |
| 9(Provision for earthing) |
- |
2500 |
|
10% discount offered to BIS |
| 10(Terminals) |
- |
2500 |
|
10% discount offered to BIS |
| 11(External & Internal Wiring) |
- |
5000 |
|
10% discount offered to BIS |
| 12(Protection against electric shock) |
- |
2500 |
|
10% discount offered to BIS |
| 13(Endurance Tests and Thermal Tests) |
- |
10000 |
|
10% discount offered to BIS |
| 14(Resistance to Dust and Moisture) |
- |
7000 |
|
10% discount offered to BIS |
| 15(Insulation Resistance and Electric Strength) |
- |
3000 |
|
10% discount offered to BIS |
| 16(Resistance to Heat , fire and tracking) |
- |
5000 |
|
10% discount offered to BIS |
| 17(Photometric Test) |
- |
25000 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Luminaries size restricted to 1000 mm for photometric test, UV Radiations as per C. 4
.24 & Annex P of IS 10322 (Part 1):2014, Short-circuit protection as per cl.4.26 IPX8 upto 1.3m |
| 11870 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
1500 |
|
10% discount offered to BIS |
| 6(Interchangeability) |
- |
3000 |
|
10% discount offered to BIS |
| 7(Protection against accidental contact with live parts) |
- |
2000 |
|
10% discount offered to BIS |
| 8(Insulation Resistance and Electric Strength) |
- |
10000 |
|
10% discount offered to BIS |
| 9(MECHANICAL STRENGTH) |
- |
2500 |
|
10% discount offered to BIS |
| 10(cap temperature) |
- |
5000 |
|
10% discount offered to BIS |
| 11(Resistance to Heat) |
- |
4000 |
|
10% discount offered to BIS |
| 12(Resistance to Flame and Ignition) |
- |
5500 |
|
10% discount offered to BIS |
| 13(Fault conditions) |
- |
6500 |
|
10% discount offered to BIS |
| 14(Creepage distance and clearances) |
- |
5500 |
|
10% discount offered to BIS |
| Annex A(Ovreview of systems composed of LED modules and control gear) |
- |
400 |
|
10% discount offered to BIS |
| Annex B(Lamps with operating position limitations) |
- |
400 |
|
10% discount offered to BIS |
| 15(Selection of lamps for tests (Sampling)) |
- |
500 |
|
10% discount offered to BIS |
| 16(Condition of compliance) |
- |
400 |
|
10% discount offered to BIS |
| 17(Tests) |
- |
200 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Restricted only to Cap type B22d, E14 & E27 |
| 11871 |
BIS, Central Laboratory (CL)
| None
| IS 3903 (1984) |
Specification for dimethoate emulsifiable concentrates |
- |
Rs. 3300.00/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.3.2 (Acidity) |
- |
|
|
|
| 2.3.1 (Dimethoate Content, NV upto 9) |
- |
|
|
|
| 2.3.1 (Dimethoate Content, NV above 50) |
- |
|
|
|
| 2.2.3 (Flash Point) |
- |
|
|
|
| 2.1 (Constituents) |
- |
|
|
|
| 2.2.1 (Description) |
- |
|
|
|
| 2.2.2 (Cold Test) |
- |
|
|
|
| 2.2.4 (emulsion Stability) |
- |
|
|
|
| 2.2.5 (Heat Stability) |
- |
|
|
|
| 2.2.4 (emulsion Stability) |
- |
|
|
|
| 2.2.5 (Heat Stability) |
- |
|
|
|
| 2.3.1 (Dimethoate Content, NV above 9 and below 50) |
- |
|
|
|
|
- |
- EXCLUDING Cl. 2.3.1 Dimethoate Content; |
| 11872 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 366 (1991) |
Electric iron - Specification (Fourth Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.0(Measurement of Heating up time) |
- |
500 |
|
10% discount offered to BIS |
| 11.0(Measurement of sole plate temperature) |
- |
500 |
|
10% discount offered to BIS |
| 12.0(Measurement of Tempearture Distribution) |
- |
700 |
|
10% discount offered to BIS |
| 13.0(Measurement of Initial overswing temperature and Heating up excess temperature) |
- |
500 |
|
10% discount offered to BIS |
| 14.0(Measurement of Cyclic fluctuation of temperature of hottest point ) |
- |
1000 |
|
10% discount offered to BIS |
| 16.0(Measurement of Thermostatic staibility) |
- |
1000 |
|
10% discount offered to BIS |
| 17(Measurement of Thermostatic staibility) |
- |
500 |
|
10% discount offered to BIS |
| 7.0(Classification (as per Cl.6 of IS 302-2-3 and Cl.6.1 of IS 302-1)) |
- |
100 |
|
10% discount offered to BIS |
| 7.0(Classification (as per Cl.6 of IS 302-2-3 and Cl.6.2 of IS 302-1)) |
- |
100 |
|
10% discount offered to BIS |
| 9.0(Protection against access to live parts (as per Cl. 8 of IS 302-2-3 and IS 302-1)) |
- |
800 |
|
10% discount offered to BIS |
| 9.0(Power input and current (as per Cl. 10 of IS 302-2-3 and IS 302-1)) |
- |
400 |
|
10% discount offered to BIS |
| 9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
900 |
|
10% discount offered to BIS |
| 9.0(Leakage current and Electric Strength at Operating Temperature (as per Cl. 13 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
10% discount offered to BIS |
| 9.0(Transient Overvoltage (as per of Cl. 14 of IS 302-2-3 and Table 6 of IS 302-1)) |
- |
1000 |
|
10% discount offered to BIS |
| 9.0(Moisture Resistance (as per of Cl.15 of IS 302-2-3 and IS 302-1)) |
- |
1500 |
|
10% discount offered to BIS |
| 9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
1000 |
|
10% discount offered to BIS |
| 9.0(Staibilty and mechanical hazards (as per of Cl.20 of IS 302-2-3 and IS 302-1) ) |
- |
1000 |
|
10% discount offered to BIS |
| 9.0(Mechanical strength (as per of Cl.21 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
10% discount offered to BIS |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
10% discount offered to BIS |
| 9.0(Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
10% discount offered to BIS |
| 9.0(Components (as per of Cl.24 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
10% discount offered to BIS |
| 9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
400 |
|
10% discount offered to BIS |
| 9.0(Terminals for external conductors (as per of Cl.26 of IS 302-2-3 and IS 302-1) ) |
- |
300 |
|
10% discount offered to BIS |
| 9.0(Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
1000 |
|
10% discount offered to BIS |
| 9.0(Screw and connections (as per of Cl.28 of IS 302-2-3 and IS 302-1)) |
- |
300 |
|
10% discount offered to BIS |
| 9.0(Clearances, creepage distances and solid insulation (as per of Cl.29 of IS 302-2-3 and IS 302-1)) |
- |
800 |
|
10% discount offered to BIS |
| 9.0(Resistance to Heat and Fire (as per of Cl.30 of IS 302-2-3 and IS 302-1)) |
- |
1000 |
|
10% discount offered to BIS |
| 9.0(Resistance to Rusting (as per of Cl.31 of IS 302-2-3 and IS 302-1)) |
- |
800 |
|
10% discount offered to BIS |
| 9.0(Leakage current and Electric Strength at Operating Temperature (as per Cl. 13 of IS 302-2-3 and IS 302-1)) |
- |
1000 |
|
10% discount offered to BIS |
| 16 of IS 302-2-3(Leakage current electric strength) |
- |
500 |
|
10% discount offered to BIS |
| 15(MEASUREMENT OF TEMPERATURE DROP UNDER LOAD) |
- |
100 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Abnormal operation (Cl.19.11.4.1 to 19.11.4.4 |
| 11873 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 302 : Part 2 : Sec 3 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 3 electric iron (First Revision) |
- |
12495 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
100 |
|
10% discount offered to BIS |
| 7.14(Marking- IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
800 |
|
10% discount offered to BIS |
| 10(Power Input and Current, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 11(Heating, IS 302-1) |
- |
900 |
|
10% discount offered to BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 14(Transient Over Voltages, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
| 15.2(Moisture Resistance, IS 302-1) |
- |
1200 |
|
10% discount offered to BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
| 19.4(Abnormal Operation, IS 302-1) |
- |
800 |
|
10% discount offered to BIS |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 21.1(Mechanical Strength, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 21.2(Mechanical Strength, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 22(Construction, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 22.101(Construction) |
- |
300 |
|
10% discount offered to BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 24.1(Components, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 27.1(Provision for Earthing, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 28(Screws & Connections, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
800 |
|
10% discount offered to BIS |
| 32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
0.0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
10% discount offered to BIS |
| 7.3(Marking- IS 302-1) |
- |
0.0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0.0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0.0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0.0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0.0 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
0.0 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
0.0 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
0.0 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
0.0 |
|
- |
| 7.101(Marking) |
- |
0.0 |
|
- |
| 15.3(Moisture Resistance, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 15.1(Moisture Resistance, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 19.5(Abnormal Operation, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
| 19.7(Abnormal Operation) |
- |
500 |
|
10% discount offered to BIS |
| 19.9(Abnormal Operation) |
- |
500 |
|
10% discount offered to BIS |
| 21.101(Mechanical Strength, IS 302-2-3) |
- |
200 |
|
10% discount offered to BIS |
| 22.102(Construction) |
- |
200 |
|
10% discount offered to BIS |
| 22.103(Construction) |
- |
200 |
|
10% discount offered to BIS |
| 22.104(Construction) |
- |
200 |
|
10% discount offered to BIS |
| 22.105(Construction) |
- |
200 |
|
10% discount offered to BIS |
| 22.106(Construction) |
- |
200 |
|
10% discount offered to BIS |
| 22.107(Construction) |
- |
200 |
|
10% discount offered to BIS |
| 23.2(Internal Wiring, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 23.3(Internal Wiring, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 23.4(Internal Wiring, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 23.5(Internal Wiring, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 23.6(Internal Wiring, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 23.7(Internal Wiring, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 23.8(Internal Wiring, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 23.9(Internal Wiring, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 23.10(Internal Wiring, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 24.2(Components, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 24.4(Components, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 27.2(Provision for Earthing, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 27.3(Provision for Earthing, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 27.4(Provision for Earthing, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 27.5(Provision for Earthing, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
600 |
|
10% discount offered to BIS |
| 30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
900 |
|
10% discount offered to BIS |
| 19.11.4.4(Surge immunity test) |
- |
2000 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Exclusions: EMI/EMC tests (electrostatic Discharges, Radiant Fields, Fast Transient burst,
Voltage surges, Injected current, voltage dips & Interruptions, Mains signals)
[cl.19.11.4.1 to Cl.19.11.4.7], Radiation, Toxicity & Similar Hazards (cl.32), Components (Cl.24) |
| 11874 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 302 : Part 2 : Sec 201 (2008) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 201 electric immersion water heaters (First Revision) |
- |
13969 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 of IS 302-‐2-‐201:2008(Classification) |
- |
500 |
|
10% discount offered to BIS |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
600 |
|
10% discount offered to BIS |
| Cl.8 of IS 302‐2-201: 2008(Protection Against Access to Live Parts) |
- |
800 |
|
10% discount offered to BIS |
| Cl.10 of IS 302‐2‐201:2008(Power Input and Current ) |
- |
1200 |
|
10% discount offered to BIS |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1100 |
|
10% discount offered to BIS |
| Cl.13 of IS 302-2-201: 2008(Leakage Current & Electric Strength at Operating Temperature) |
- |
700 |
|
10% discount offered to BIS |
| Cl.14 of IS 302‐2-201:2008(Transient Over Voltages ) |
- |
900 |
|
10% discount offered to BIS |
| Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
1200 |
|
10% discount offered to BIS |
| Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
1400 |
|
10% discount offered to BIS |
| Cl.17 of IS 302‐2-201: 2008(Overload Protection of Transformers & Associated Circuits) |
- |
700 |
|
10% discount offered to BIS |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1500 |
|
10% discount offered to BIS |
| Cl.20 of IS 302-2-201: 2008(Stability & Mechanical Hazards) |
- |
500 |
|
10% discount offered to BIS |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
400 |
|
10% discount offered to BIS |
| Cl.22 of IS 302-2-201: 2008(Construction) |
- |
400 |
|
10% discount offered to BIS |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
500 |
|
10% discount offered to BIS |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
400 |
|
10% discount offered to BIS |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
600 |
|
10% discount offered to BIS |
| Cl.26 of IS 302-2-201: 2008(Terminals for External Conductors) |
- |
400 |
|
10% discount offered to BIS |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
600 |
|
10% discount offered to BIS |
| Cl.28 of IS 302-2-201: 2008(Screws & Connections ) |
- |
400 |
|
10% discount offered to BIS |
| Cl.29 of IS 302-2‐201:2008(Clearances, Creepage Distances and Solid Insulation ) |
- |
600 |
|
10% discount offered to BIS |
| Cl.30 of IS 302-2‐201:2008(Resistance to Heat and Fire ) |
- |
1200 |
|
10% discount offered to BIS |
| Cl.31 of IS 302-2-201:2008(Resistance of Rusting ) |
- |
700 |
|
10% discount offered to BIS |
| 19.11.4.4(Surge immunity test) |
- |
2000 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Restricted Upto 5KW EMI/EMC tests (Electrostatic discharges, radiant fields, fast transient bursts, voltage
surges, injected current, voltage dip and interruption, mains signals) (Cl.19.11.4.1 to
19.11.4.7), Components (Capacitors for radio interference suppression, isolating
transformer, coupler) (Cl.24.1.1, 24.1.2, 24.1.5) cl.22.16 automatic cord reel, cl
22.32 test on ceramic materials cl.22.46 software |
| 11875 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
75000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5(Components) |
- |
500 |
|
10% discount offered to BIS |
| 4.6(Power interface) |
- |
1500 |
|
10% discount offered to BIS |
| 4.7(Marking & instructions) |
- |
1000 |
|
10% discount offered to BIS |
| 5.1(Protection against shock and energy hazards) |
- |
1000 |
|
10% discount offered to BIS |
| 5.2(Requirement of auxiliary circuits) |
- |
2000 |
|
10% discount offered to BIS |
| 5.3(Protective earthing and bonding) |
- |
1500 |
|
10% discount offered to BIS |
| 5.4(AC and DC power isolation) |
- |
1500 |
|
10% discount offered to BIS |
| 5.5(Over current and earth fault condition) |
- |
2000 |
|
10% discount offered to BIS |
| 5.6(Safety interlocks) |
- |
2500 |
|
10% discount offered to BIS |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
5000 |
|
10% discount offered to BIS |
| 6.1(Wiring, connections and supply) |
- |
500 |
|
10% discount offered to BIS |
| 6.2(Connection to power) |
- |
2000 |
|
10% discount offered to BIS |
| 6.3(Wiring terminals for external power conductors) |
- |
1500 |
|
10% discount offered to BIS |
| 7.1(Enclosure) |
- |
3000 |
|
10% discount offered to BIS |
| 7.2(STABILITY) |
- |
3000 |
|
10% discount offered to BIS |
| 7.3(MECHANICAL STRENGTH) |
- |
15000 |
|
10% discount offered to BIS |
| 7.4(Construction details) |
- |
3000 |
|
10% discount offered to BIS |
| 7.6(Battery location) |
- |
2000 |
|
10% discount offered to BIS |
| 7.7(Temperature rise) |
- |
8000 |
|
10% discount offered to BIS |
| 8.1(General procision for earth leakage) |
- |
1500 |
|
10% discount offered to BIS |
| 8.2(Electric Strength) |
- |
5000 |
|
10% discount offered to BIS |
| 8.3(Abnormal operating and fault conditions) |
- |
8000 |
|
10% discount offered to BIS |
| 9.0(Connection to telecommunication networks) |
- |
6000 |
|
10% discount offered to BIS |
| 7.5(Resistance to fire) |
- |
5000 |
|
10% discount offered to BIS |
| 4.5/RD 1.5(Components) |
- |
500 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Exclusions: Restricted upto 10Kva Single Phase only. Excluding: Components (Cl.4.5/ RD, CI.
1.5), Winding Wires (Cl. 2.10.5.3), Semiconductor Devices (Cl. 2.10.5.4),
SMPS/Main transformer (cl.2.10.5.11); PCB Material (cl.2.10.6); SMPS/ Mains
Transformer (Cl. 2.10.5.11), Wire in wound components (Cl. 2.10.5.12), Wire with
solvent based enamel in wound components (Cl. 2.10.5.13), Additional
insulation in wound components (Cl. 2.10.5.14), Tests for pollution degree 1
environment & for insulating compound (Cl. 2.10.10), Tests for semiconductor
devices & for cemented joints (Cl. 2.10.11), Enclosed & sealed parts (Cl. 2.10.12),
Internal Wire (Cl. 3.1.4), Batteries (Cl.4.3.8), Non-rewirable Plug with PVC
Sheathed Cable (Cl. 3.2.5), Construction of printed circuit boards (Cl.5.7/RD/2.10.6),
Wiring, connection and supply (Cl.6.1.1/RD 3.1.4), Batteries (Cl. 4.3.8), Performance Tests: Simulators (ESD/EFT/Voltage Dip Interruption/PFMF), Gas Concentration, Ventilation of Battery Compartments (Cl.7.4.3, Cl.7.6.7 & Annex- M), Non-rewirable plug with PVC sheathed cable (Cl.3.2.5), Performance tests:simulators immunity to Low frequency signals (Annex L.5.2 (IEC 32040-2,CI.7.3)). Switches & Relays (cl.5.6.1 / RD cl.2.8.7); Insulating Conductors (cl.6.1.1/RD
cl.3.1.4) |
| 11876 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
- |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
1500 |
|
10% discount offered to BIS |
| 8(Protection against accidental contact with live parts) |
- |
2500 |
|
10% discount offered to BIS |
| 9(Terminals) |
- |
2000 |
|
10% discount offered to BIS |
| 10(PROVISION FOR EARTHING) |
- |
2500 |
|
10% discount offered to BIS |
| 11(MOISTURE RESISTANCE) |
- |
8000 |
|
10% discount offered to BIS |
| 12(Electric Strength) |
- |
2000 |
|
10% discount offered to BIS |
| 13(Thermal endurance test for winding of ballasts) |
- |
5000 |
|
10% discount offered to BIS |
| 14(Fault conditions) |
- |
5000 |
|
10% discount offered to BIS |
| 16(Construction) |
- |
5000 |
|
10% discount offered to BIS |
| 17(Creepage distance and clearances) |
- |
2500 |
|
10% discount offered to BIS |
| 18(Screws, current carrying parts and connections) |
- |
2000 |
|
10% discount offered to BIS |
| 19(Resistance to heat, fire and tracking) |
- |
4000 |
|
10% discount offered to BIS |
| 20(Resistance to corrosion) |
- |
3000 |
|
10% discount offered to BIS |
| 15.4 (b)(Cold impact) |
- |
0.00 |
|
10% discount offered to BIS |
| 15(Transformer heating) |
- |
1200 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Components: enclosures (Cl.16), Bridging resistor in primary circuit (Cl.16), capacitor
an RC units (Cl.16), RF suppression (X-Y capacitors) (Cl.16), Inductor (Cl.16), MOV/VDR (CI.16), SMPS/Mains Transformer (cl.16); PCB material (cl.16); Metal base PCB for LED (cl.19);
Transparent cover (Cl.19), Bobbin (Cl.19), Insulated tape (Cl.16), heat shrinkage
cleeve (Cl.16), connector (Cl.16), Fuse (Cl.16), Internal wire (Cl.16), LED (Cl.16), opto-coupler (CI.16), EMI/EMC filter (Cl.16), Winding wire (Cl.16), Thin sheet materials (Cl.16) |
| 11877 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 16644 (2018) |
Stress - Relieved, low relaxation steel wire for prestressed concrete - Specification |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 5.1.1 (Sulphur) |
- |
|
|
|
| Clause 5.1.1 (Phosphorus) |
- |
|
|
|
|
- |
- Except 8.7 Stress relaxation, 8.8 Fatigue test |
| 11878 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.5(Components) |
- |
500 |
|
10% discount offered to BIS |
| 1.6(Power interface .) |
- |
1500 |
|
10% discount offered to BIS |
| 1.7(Markings and instructions) |
- |
1000 |
|
10% discount offered to BIS |
| 2.1(Protection from electric shock and energy hazards) |
- |
1000 |
|
10% discount offered to BIS |
| 2.2(SELV circuits) |
- |
1500 |
|
10% discount offered to BIS |
| 2.3(TNV circuits) |
- |
2000 |
|
10% discount offered to BIS |
| 2.4(Limited current circuits) |
- |
2000 |
|
10% discount offered to BIS |
| 2.5(Limited power sources .) |
- |
2500 |
|
10% discount offered to BIS |
| 2.6(Provisions for earthing and bonding) |
- |
1500 |
|
10% discount offered to BIS |
| 2.8(Safety interlocks) |
- |
3000 |
|
10% discount offered to BIS |
| 2.9(Electrical insulation) |
- |
5000 |
|
10% discount offered to BIS |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
5000 |
|
10% discount offered to BIS |
| 3.1(General) |
- |
500 |
|
10% discount offered to BIS |
| 3.2(Connection to a mains supply) |
- |
2000 |
|
10% discount offered to BIS |
| 3.3(Wiring terminals for connection of external conductors) |
- |
1500 |
|
10% discount offered to BIS |
| 3.4(Disconnection from the mains supply) |
- |
1000 |
|
10% discount offered to BIS |
| 3.5(Interconnection of equipment) |
- |
1000 |
|
10% discount offered to BIS |
| 4.1(Stability) |
- |
3000 |
|
10% discount offered to BIS |
| 4.2(Mechanical strength) |
- |
1500 |
|
10% discount offered to BIS |
| 4.3(Design and construction) |
- |
3000 |
|
10% discount offered to BIS |
| 4.4(Protection against hazardous moving parts) |
- |
5000 |
|
10% discount offered to BIS |
| 4.5(Thermal requirements) |
- |
8000 |
|
10% discount offered to BIS |
| 4.6(Openings in enclosures) |
- |
3000 |
|
10% discount offered to BIS |
| 4.7(Resistance to fire) |
- |
5000 |
|
10% discount offered to BIS |
| 5.1(Touch current and protective conductor curren) |
- |
3500 |
|
10% discount offered to BIS |
| 5.2(Electric strength) |
- |
5000 |
|
10% discount offered to BIS |
| 5.3(Abnormal operating and fault conditions) |
- |
8000 |
|
10% discount offered to BIS |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
2000 |
|
10% discount offered to BIS |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
2500 |
|
10% discount offered to BIS |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
2000 |
|
10% discount offered to BIS |
| 7.1(General) |
- |
500 |
|
10% discount offered to BIS |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
1000 |
|
10% discount offered to BIS |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
2000 |
|
10% discount offered to BIS |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
3000 |
|
10% discount offered to BIS |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
1100 |
|
10% discount offered to BIS |
| Annex A3(Hot flaming oil test) |
- |
2500 |
|
10% discount offered to BIS |
| Annex C(Transformers) |
- |
1200 |
|
- |
| Annex B(Motor tests under abnormal conditions) |
- |
1500 |
|
10% discount offered to BIS |
| Annex K(Thermal Control) |
- |
800 |
|
10% discount offered to BIS |
| Annex Q(Voltage Dependent Resistors) |
- |
500 |
|
10% discount offered to BIS |
| Annex U(Insulating winding wires for use without interleaved insulation) |
- |
500 |
|
10% discount offered to BIS |
| Annex CC(Evaluation of integrated circuit (IC) current limiters) |
- |
500 |
|
10% discount offered to BIS |
| Annex DD(Requirements for the mounting means of a rack mounted equipment) |
- |
1100 |
|
10% discount offered to BIS |
| Annex EE(Household and home/ office document/ media shredders) |
- |
500 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Excluding: Component (Cl.1.5), Moving parts (Cl.2.8.5),Semiconductor devices (Cl.2.10.5.4), Insulation in wound component (Cl.2.10.5.11), Wire in wound component (Cl.2.10.5.12), Wire with solvent based enamel in wound components (Cl.2.10.5.13), Additional insulation in wound components (Cl.2.10.5.14), Test on coated printed boards and coated components (Cl.2.10.8.1), Test for Pollution Degree 1 environment and insulating compound (Cl.2.10.10), Tests for semiconductor devices and for cemented joints(Cl.2.10.11), Enclosed and sealed parts(Cl.2.10.12), Ac power supply cord(Cl.3.2.5.1), High pressure lamps (Cl.4.2.9), Radiation (Cl.4.3.13), Ionizing radiation (Cl.4.3.13.2), Effect of UV radiation on materials (Cl.4.3.13. & Annex Y), Human exposure to UV radiation (Cl.4.3.13.4), Laser including LED (Cl.4.3.13.5), Light emitting diodes (LED's) (Cl.4.3.13.5.2), Materials for air filter assemblies (4.7.3.5), Materials used in high voltage components (4.7.3.6) Electromechanical components (Cl. 5.3.5), Unattended Equipments (Cl.5.3.8) Insulating winding wires (c.2.10.5.2 & Annex U), Evaluation of IC current limiters (Annex CC) |
| 11879 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 17111 (2019) |
Heat - Treated steels, alloy steels and free - Cutting steels - Ball and roller bearing steels |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 7.6 (Shape, dimensions and tolerances) |
- |
|
|
|
| Cl.7.1.2, Table- 3 (Carbon ) |
- |
|
|
|
| Cl.7.1.2, Table- 3 (Silicon) |
- |
|
|
|
| Cl.7.1.2, Table- 3 (Manganese) |
- |
|
|
|
| Cl.7.1.2, Table- 3 (Sulphur) |
- |
|
|
|
| Cl.7.1.2, Table- 3 (Phosphorus) |
- |
|
|
|
| Cl.7.1.2, Table- 3 (Nickel) |
- |
|
|
|
| Cl.7.1.2, Table- 3 (Chromium) |
- |
|
|
|
| Cl.7.1.2, Table- 3 (Molybdenum) |
- |
|
|
|
| Cl.7.1.2, Table- 3 (Aluminium) |
- |
|
|
|
| Cl.7.1.2, Table- 3 (Copper) |
- |
|
|
|
| Cl.7.1.2, Table- 3 (Titanium) |
- |
|
|
|
| Cl.7.1.2, Table- 3 (Nitrogen) |
- |
|
|
|
| 7.2.1 (Austenitic grain size) |
- |
|
|
|
| 7.2.2 (Spheroidization and distribution of carcides) |
- |
|
|
|
| 7.3.1 (Microscopic Inclusion) |
- |
|
|
|
| 7.3.2 (Macroscopic Inclusion) |
- |
|
|
|
| CL 7.6 (AVG Outer dia (08)) |
- |
|
|
|
| CL 7.6 (MAX Ovality (08)) |
- |
|
|
|
|
- |
- Except Al, Ca, O, Ti, V, W |
| 11880 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 410 (1977) |
Specification for cold rolled brass sheet, strip and foil (Third Revision) |
- |
1500/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1 Table-1 (Cu) |
- |
|
|
|
| 6.1 Table-1 (Pb) |
- |
|
|
|
| 6.1 Table-1 (Fe) |
- |
|
|
|
| 6.1 Table-1 (Zn) |
- |
|
|
|
| 4.0 (Freedom from defects) |
- |
|
|
|
| 7.1.1 (Tensile Test) |
- |
|
|
|
| Table-2 (Vickers Hardness) |
- |
|
|
|
| Table-2 (Transverse Bend) |
- |
|
|
|
| Table-2 (Longitudinal Bend) |
- |
|
|
|
| Table-2 (Thickness) |
- |
|
|
|
| 7.1.5 (Grain Size - IS 410) |
- |
|
|
|
|
- |
- Except Total Impurities |