| 11821 |
GLOBAL COMPLIANCE LABORATORY INDIA, GHAZIABAD
| 5172706
| IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
Class - 1 and 2 |
64000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
2000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
| 10.1(Power input) |
- |
3000 |
|
- |
| 10.2(Current input) |
- |
3000 |
|
- |
| 11.1(General) |
- |
3000 |
|
- |
| 11.2(General) |
- |
3000 |
|
- |
| 11.3(Heating) |
- |
2000 |
|
- |
| 13.1(General) |
- |
2000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
2000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
2000 |
|
- |
| 15.0(General) |
- |
2000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
2000 |
|
- |
| 15.2(Spillage Test) |
- |
2000 |
|
- |
| 15.3(Humidity Test) |
- |
2000 |
|
- |
| 16.0(General) |
- |
800 |
|
- |
| 16.1(General) |
- |
800 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
800 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
600 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
2000 |
|
- |
| 19(Abnormal Operation) |
- |
2000 |
|
- |
| 20(Stability test) |
- |
1000 |
|
- |
| 21(Mechanical Strength Test) |
- |
3000 |
|
- |
| 22(Construction verification related test) |
- |
2000 |
|
- |
| 23(General) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
2000 |
|
- |
| 26(Terminals for external conductors) |
- |
2000 |
|
- |
| 27(Provision for earthing) |
- |
2000 |
|
- |
| 28(Screw test and connections) |
- |
2000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
3000 |
|
- |
| 30.1(Ball pressure test) |
- |
700 |
|
- |
| 30.2(Glow Wire Test) |
- |
700 |
|
- |
| 30.2(Needle Flame Test) |
- |
600 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
1000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
- |
| 11.4(Heating appliances) |
- |
2000 |
|
- |
| 11.5(Motor-operated appliances) |
- |
2000 |
|
- |
| 11.6(Combined appliances) |
- |
2000 |
|
- |
| 11.7(Duration corresponding) |
- |
2000 |
|
- |
| 11.8(Temperature rise) |
- |
2000 |
|
- |
|
20 Jun, 2026 |
- Exclusion: Cl. 19.11.4.1 (Electrostatic discharges), Cl. 19.11.4.2 (Radiated fields), Cl. 19.11.4.3 (Fast transient bursts), Cl. 19.11.4.4 (Surge immunity test), Cl. 19.11.4.5 (Immunity to conducted discharges), Cl. 19.11.4.6 (Class 3 Voltage dips and interruptions), Cl. 19.11.4.7 (Harmonics), Cl. 24 (Components), Cl. 32 (Radiation Toxicity and Similar Hazards).
"(1)Cooking ranges, hobs, ovens and similar appliances, (2)Commercial Dispensing Appliances and Vending Machines, (3) spin extractors
(For testing charges please refer relevant Part 2 standard in LIMS)" |
| 11822 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 3443 (1980) |
Crane Rail Sections - |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-A) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-B) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-C) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-D) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-E) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-F) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-G) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-H) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-R4) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-R5) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-R6) |
- |
|
|
|
| 8.1-TABLE 2 (DIMENSIONS OF CRANE RAILS-R7) |
- |
|
|
|
| 9.1 (Freedom from defects) |
- |
|
|
|
| 9.2 (Freedom from defects- Asymmetry in the flange) |
- |
|
|
|
| 9.2 (Freedom from defects- Asymmetry in the head) |
- |
|
|
|
| Cl. 4, Table 1 (Chemical Composition - Carbon) |
- |
|
|
|
| Cl. 4, Table 1 (Chemical Composition - Manganese) |
- |
|
|
|
| Cl. 4, Table 1 (Chemical Composition - Silicon) |
- |
|
|
|
| Cl. 4, Table 1 (Chemical Composition - Sulphur) |
- |
|
|
|
| Cl. 4, Table 1 (Chemical Composition - Phosphorous) |
- |
|
|
|
|
- |
- - |
| 11823 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
- |
37300 View breakup
Class I & II Product : (AMPLIFIERS WITH INPUT POWER 2000W AND ABOVE, ELECTRONIC GAMES (VIDEO), ELECTRONIC MUSICAL SYSTEMS WITH INPUT POWER 200W AND ABOVE, OPTICAL DISC PLAYERS WITH BUILT IN AMPLIFIERS OF INPUT POWER 200W AND ABOVE, PLASMA/LCD/LED TELEVISIONS OF SCREEN SIZE 32"; AND ABOVE, POWER ADAPTORS FOR AUDIO, VIDEO & SIMILAR ELECTRONIC APPARATUS, PLASMA/ LCD/LED TELEVISION OF SCREEN SIZE UP-TO 32, WIRELESS HEADPHONE AND EARPHONE, ELECTRONIC MUSICAL SYSTEM WITH INPUT POWER BELOW 200 WATTS, TELEVISION OTHER THAN PLASMA/ LCD/LED TVS, WIRELESS MICROPHONE, VIDEO CAMERA, WEBCAM (FINISHED PRODUCT), SMART SPEAKERS (WITH AND WITHOUT DISPLAY), BLUETOOTH SPEAKERS)- Rs. 45000/-
Class III Product : (WIRELESS HEADPHONE AND EARPHONE, WIRELESS MICROPHONE, VIDEO CAMERA, WEBCAM (FINISHED PRODUCT), SMART SPEAKERS (WITH AND WITHOUT DISPLAY), BLUETOOTH SPEAKERS)- Rs. 30000/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking and instructions) |
- |
1000 |
|
- |
| 7(Heating under normal operating conditions) |
- |
1000 |
|
- |
| 8(Constructional requirements with regard to the protection against electric shock) |
- |
500 |
|
- |
| 10(Insulation requirements) |
- |
500 |
|
- |
| 11(Fault conditions) |
- |
1000 |
|
- |
| 12(Mechanical strength) |
- |
1000 |
|
- |
| 13(CLEARANCES and CREEPAGE DISTANCES) |
- |
1000 |
|
- |
| 15(TERMINALS) |
- |
1000 |
|
- |
| 16(External flexible cords) |
- |
1000 |
|
- |
| 17(Electrical connections and mechanical fixings) |
- |
1000 |
|
- |
| 19(Stability and mechanical hazards) |
- |
1000 |
|
- |
| 4(General test conditions) |
- |
100 |
|
- |
| 14(Components) |
- |
100 |
|
- |
| 9(Electric shock hazard under normal operating conditions) |
- |
100 |
|
- |
| Cl.5.1 of Cl.5(General requirements) |
- |
100 |
|
- |
| Cl.5.1-i) of Cl.5(Comprehensible and easily discernible) |
- |
100 |
|
- |
| Cl.5.1-ii) of Cl.5(Permanent durability against water and petroleum spirit) |
- |
100 |
|
- |
| Cl.5.2 of Cl.5(Identification and supply ratings) |
- |
100 |
|
- |
| Cl.5.2 a) of Cl.5(Identification, maker) |
- |
100 |
|
- |
| Cl.5.2 b) of Cl.5(Model number or type reference) |
- |
100 |
|
- |
| Cl.5.2 d) of Cl.5(Nature of supply) |
- |
100 |
|
- |
| Cl.5.2 e) of Cl.5(Rated supply voltage) |
- |
100 |
|
- |
| Cl.5.2 f) of Cl.5(Mains frequency if safety dependant) |
- |
100 |
|
- |
| Cl.5.2 g) of Cl.5(Rated current or power consumption for apparatus supplied by supply apparatus for general use, on apparatus or in instruction manual: Measured current or power consumption: Deviation % (max 10%):) |
- |
100 |
|
- |
| Cl.5.2 h) of Cl.5(Rated current or power consumption for apparatus intended for connection to an a.c. mains supply:Measured current or power consumption for Television set: Deviation % (max 10%):) |
- |
100 |
|
- |
| Cl.5.2 h)-i) of Cl.5(appliance coupler for Class I is used for Class II equipment with functional earth connection, the requirements of Clause 15 and Clause 16 related to Class I construction shall be applied up to the connecting point of the protective(earthing) conductor to the functional earth.) |
- |
100 |
|
- |
| Cl.5.2 h)-ii) of Cl.5(Graphical symbols placed on the apparatus, whether required by this standard or not, shall be in accordance with IEC 60417 or ISO 3864-2 or ISO 7000, if available. In the absence of suitable symbols, the manufacturer may design specific graphical symbols.) |
- |
100 |
|
- |
| Cl.5.2 h)-iii) of Cl.5(Care shall be taken so that additional markings and instructions not required by this standard do not contradict the markings and instructions required by this standard . Symbols placed on the Equipment shall be explained in the user manual.) |
- |
100 |
|
- |
| Cl.5.3 of Cl.5(Terminals) |
- |
100 |
|
- |
| Cl.5.3a) of Cl.5(Earth terminal) |
- |
100 |
|
- |
| Cl.5.3b) of Cl.5(Hazardous live terminals) |
- |
100 |
|
- |
| Cl.5.3c) of Cl.5(Markings on supply output terminals) |
- |
100 |
|
- |
| Cl.5.4 of Cl.5(Caution marking) |
- |
100 |
|
- |
| Cl.5.4a) of Cl.5(Use of triangle with exclamation mark) |
- |
100 |
|
- |
| Cl.5.4b) of Cl.5(Marking on loudspeaker grille, IEC 60417-5036) |
- |
100 |
|
- |
| Cl.5.4c) of Cl.5(User-replaceable coin / button cell battery marking) |
- |
100 |
|
- |
| Cl.5.5 of Cl.5(Instructions) |
- |
100 |
|
- |
| Cl.5.5 of Cl.5(Instructions) |
- |
100 |
|
- |
| Cl.5.5 of Cl.5(Instructions) |
- |
100 |
|
- |
| Cl.5.5.1 of Cl.5.5(Safety relevant information) |
- |
100 |
|
- |
| Cl.5.5.2 b) of Cl.5.5(Hazardous live terminals, instructions for wiring) |
- |
100 |
|
- |
| Cl.5.5.2 c) of Cl.5.5(Instructions for replacing lithium battery) |
- |
100 |
|
- |
| Cl.5.5.2 d) of Cl.5.5(Class I earth connection warning) |
- |
100 |
|
- |
| Cl.5.5.2 e) of Cl.5.5(Instructions for multimedia system connection) |
- |
100 |
|
- |
| Cl.5.5.2 f) of Cl.5.5(Special stability warning for attachment of the apparatus to the floor/wall) |
- |
100 |
|
- |
| Cl.5.5.2 g) of Cl.5.5(Warning: battery exposure to heat) |
- |
100 |
|
- |
| Cl.5.5.2 h) of Cl.5.5(Warning: protective film on CRT face) |
- |
100 |
|
- |
| Cl.5.5.2 i) of Cl.5.5("Warning: Non-floor standing TV
>7kg") |
- |
100 |
|
- |
| Cl.5.5.2 j) of Cl.5.5("Warning: User replaceable coin
/ button cell battery") |
- |
100 |
|
- |
| Cl.5.5.3 (a-b) of Cl.5.5(Disconnect device: plug/coupler or all-pole mains switch location, accessibility and markings) |
- |
100 |
|
- |
| Cl.5.5.3 c) of Cl.5.5(Instructions for permanently connected equipment) |
- |
100 |
|
- |
| Cl.5.5.3 c) i) of Cl.5.5(Marking, signal lamps or similar for completely disconnection from the mains) |
- |
100 |
|
- |
| Cl.7.1 of Cl.7(General) |
- |
100 |
|
- |
| "Cl.7.1.1 of Cl.7.1 Table-3"(Requirements) |
- |
100 |
|
- |
| "Cl.7.1.2 of Cl.7.1 Table-3"(Accessible parts) |
- |
100 |
|
- |
| "Cl.7.1.3 of Cl.7.1 Table-3"(Parts, other than windings and printed boards, providing electrical insulation) |
- |
100 |
|
- |
| "Cl.7.1.4 of Cl.7.1 Table-3"(Parts acting as a support or a mechanical barrier) |
- |
100 |
|
- |
| "Cl.7.1.5 of Cl.7.1 Table-3"(Windings) |
- |
100 |
|
- |
| "Cl.7.1.6 of Cl.7.1 Table-3"(Parts not subject to a limit under7.1.1 to 7.1.4) |
- |
100 |
|
- |
| Cl.7.2 of Cl.7(Softening temperature of insulating material supporting parts conductively connected to the mains carrying a current> 0.2 A, shall be at least 150ºC) |
- |
100 |
|
- |
| Cl.8.1 of Cl.8(Conductive parts covered by lacquer, paper, untreated textile oxide films and beads etc. considered to be bare*) |
- |
100 |
|
- |
| Cl.8.2 of Cl.8(No shock hazard when changing voltage setting device, fuse-links or handling drawers etc.) |
- |
100 |
|
- |
| Cl.8.3 of Cl.8(Insulation of hazardous live parts not provided by hygroscopic material) |
- |
100 |
|
- |
| Cl.8.4 of Cl.8(No risk of electric shock from accessible parts or from parts rendered accessible following the removal of a cover which can be removed by hand) |
- |
100 |
|
- |
| Cl.8.5 of Cl.8(Class I apparatus*) |
- |
100 |
|
- |
| Cl.8.5 i) of Cl.8(Basic insulation between hazardous live parts and earthed accessible parts *) |
- |
100 |
|
- |
| Cl.8.5 iv) of Cl.8(Protective earthing terminal *) |
- |
100 |
|
- |
| Cl.8.6 of Cl.8(Class II apparatus) |
- |
100 |
|
- |
| Cl.8.6 a) of Cl.8(Basic and supplementary insulation between hazardous live parts and accessible parts *) |
- |
100 |
|
- |
| Cl.8.6 b) of Cl.8(Reinforced insulation between hazardous live parts and accessible parts *) |
- |
100 |
|
- |
| Cl.8.8 of Cl.8(Insulation thickness and thin sheet materials) |
- |
100 |
|
- |
| Cl.8.8 i) of Cl.8(Basic or supplementary insulation > 0,4 mm (mm)*) |
- |
100 |
|
- |
| Cl.8.8 ii) of Cl.8(Reinforced insulation > 0,4 mm (mm) *) |
- |
100 |
|
- |
| Cl.8.8 iii) of Cl.8(Thin sheet material used inside the equipment) |
- |
100 |
|
- |
| Cl.8.8 iv) of Cl.8(Basic or supplementary insulation, atleast two layers, each meeting10.4) |
- |
100 |
|
- |
| Cl.8.8 v) of Cl.8(Basic or supplementary insulation, three layers any two of which meet10.4) |
- |
100 |
|
- |
| Cl.8.8 vi) of Cl.8(Reinforced insulation, two layers each of which meet 10.4) |
- |
100 |
|
- |
| Cl.8.9 of Cl.8(Adequate insulation between internal hazardous live conductors and accessible parts, or between internal hazardous live parts and conductors connected to accessible parts) |
- |
100 |
|
- |
| Cl.8.10 of Cl.8(Double insulation between accessible parts and conductors connected to the mains) |
- |
100 |
|
- |
| Cl.8.11 of Cl.8(Detaching of wires) |
- |
100 |
|
- |
| Cl.8.12 of Cl.8(Adequate fastening of windows, lenses, lamp covers etc. (pull test 20 N for 10 s)) |
- |
100 |
|
- |
| Cl.8.13 of Cl.8(Adequate fastening of windows, lenses, lamp covers etc. (pull test 20 N for 10 s)) |
- |
100 |
|
- |
| Cl.8.14 of Cl.8(No risk of damage to the insulation of internal wiring due to hot parts or sharp edges) |
- |
100 |
|
- |
| Cl.8.15 of Cl.8(Only special supply equipment can be used*) |
- |
100 |
|
- |
| Cl.8.18 of Cl.8(Disconnection from the mains) |
- |
100 |
|
- |
| Cl.8.18 i) of Cl.8(Disconnect device used in apparatus) |
- |
100 |
|
- |
| Cl.8.18 ii) of Cl.8(All-pole switch or circuit breaker with >3mm contact separation.) |
- |
100 |
|
- |
| Cl.8.18 iii) of Cl.8(Mains switch ON indication *) |
- |
100 |
|
- |
| Cl.8.19 of Cl.8(Switch not fitted in the mains cord *) |
- |
100 |
|
- |
| Cl.8.21 of Cl.8(Non-separable thin sheet material) |
- |
100 |
|
- |
| Cl.9.1.1 of Cl.9.1(Requirements) |
- |
100 |
|
- |
| Cl.9.1.1 i) of Cl.9.1(Accessible parts shall not be hazardous live) |
- |
100 |
|
- |
| Cl.9.1.1 ii) of Cl.9.1(Inaccessible terminals are not accessible or comply with relevant requirements) |
- |
100 |
|
- |
| Cl.9.1.1 iii) of Cl.9.1(For voltages >1000 V ac or >1500 V dc complies with clause 13.3.1 for basic insulation) |
- |
100 |
|
- |
| Cl.9.1.1.2 of Cl.9.1.1(Determination of hazardous live parts) |
- |
100 |
|
- |
| Cl.9.1.1.2 a) of Cl.9.1.1(Open circuit voltages) |
- |
100 |
|
- |
| Touch current measured from terminal devices using the network in annex D(Touch current measured from terminal devices using the network in annex D) |
- |
100 |
|
- |
| Cl.9.1.1.2 c) of Cl.9.1.1(The charge exceeds 45 μC) |
- |
100 |
|
- |
| Cl.9.1.1.2 d) of Cl.9.1.1(Energy of discharge not exceeding 350 mJ) |
- |
100 |
|
- |
| Cl.9.1.1.3 of Cl.9.1.1(Test with test finger and test probe) |
- |
100 |
|
- |
| Cl.9.1.2 of Cl.9.1(Shafts of operating knobs, handles, levers and the like) |
- |
100 |
|
- |
| Cl.9.1.3 of Cl.9.1(Openings ofthe enclosure) |
- |
100 |
|
- |
| Cl.9.1.4 of Cl.9.1(Terminals) |
- |
100 |
|
- |
| Cl.9.1.4 i) of Cl.9.1(Terminals) |
- |
100 |
|
- |
| Cl.9.1.4 ii) of Cl.9.1(Terminals) |
- |
100 |
|
- |
| Cl.9.1.5 of Cl.9.1(Pre-set controls) |
- |
100 |
|
- |
| Cl.9.1.6 of Cl.9.1(Withdrawal of the mains plug:) |
- |
100 |
|
- |
| Cl.9.1.6 i) of Cl.9.1(Withdrawal of the mains plug:) |
- |
100 |
|
- |
| Cl.9.1.6 ii) of Cl.9.1(Withdrawal of the mains plug:) |
- |
100 |
|
- |
| Cl.9.1.6 iii) of Cl.9.1(Withdrawal of the mains plug:) |
- |
100 |
|
- |
| Cl.9.1.7 of Cl.9.1(Resistance to external forces) |
- |
100 |
|
- |
| Cl.9.1.7 a) of Cl.9.1(Resistance to external forces) |
- |
100 |
|
- |
| Cl.9.1.7 b) of Cl.9.1(Resistance to external forces) |
- |
100 |
|
- |
| Cl.9.1.7 c) of Cl.9.1(Resistance to external forces) |
- |
100 |
|
- |
| Cl.9.2 of Cl.9(Removal of protective covers) |
- |
100 |
|
- |
| Cl.10.2 of Cl.10(Surge Test) |
- |
100 |
|
- |
| Cl.10.2 a) of Cl.10(Surge Test) |
- |
100 |
|
- |
| Cl.10.2 b) of Cl.10(Surge Test) |
- |
100 |
|
- |
| Cl.10.2 b) (i) of Cl.10(Surge Test) |
- |
100 |
|
- |
| Cl.10.4.2 ii) of Cl.10.4(Between parts separated by REINFORCED insulation) |
- |
100 |
|
- |
| Cl.10.2 b) (ii) of Cl.10(Surge Test) |
- |
100 |
|
- |
| Cl.10.2 b) (iii) of Cl.10(Surge Test) |
- |
100 |
|
- |
| Cl.10.3 of Cl.10(Humidity treatment) |
- |
100 |
|
- |
| Cl.10.4 of Cl.10(Insulation resistance and dielectric strength) |
- |
100 |
|
- |
| Cl.10.4.1 of Cl.10.4(Insulation of the insulating materials) |
- |
100 |
|
- |
| Cl.10.4.2 of Cl.10.4(Between parts of different polarity directly connected to the mains
Between parts of different polarity directly connected to the mains) |
- |
100 |
|
- |
| Cl.10.4.2 i) of Cl.10.4(Between parts separated by BASIC or SUPPLEMENTARY insulation) |
- |
100 |
|
- |
| Cl.11.1 of Cl.11(Electric Shock Hazard) |
- |
100 |
|
- |
| Cl.11.1 a) of Cl.11(Electric Shock Hazard) |
- |
100 |
|
- |
| Cl.11.1 b) of Cl.11(Electric Shock Hazard) |
- |
100 |
|
- |
| Cl.11.2 of Cl.11(Heating) |
- |
100 |
|
- |
| Cl.11.2.1 of Cl.11.2(Requirements) |
- |
100 |
|
- |
| Cl.11.2.1 i) of Cl.11.2(No danger of fire to the surroundings) |
- |
100 |
|
- |
| Cl.11.2.1 ii) of Cl.11.2(Safety not impaired by abnormal heat) |
- |
100 |
|
- |
| Cl.11.2.1 of Cl.11.2(Flames extinguish within 10 seconds) |
- |
100 |
|
- |
| Cl.11.2.1 of Cl.11.2(No hazard from softening solder) |
- |
100 |
|
- |
| Cl.11.2.2 of Cl.11.2(Measurement of temperature rises) |
- |
100 |
|
- |
| Cl.11.2.3 of Cl.11.2(Accessible parts) |
- |
100 |
|
- |
| Cl.11.2.4 of Cl.11.2(Parts, other than windings and printed boards, providing electrical insulation) |
- |
100 |
|
- |
| Cl.11.2.5 of Cl.11.2(Parts acting as a support or a mechanical barrier) |
- |
100 |
|
- |
| Cl.11.2.6 of Cl.11.2(Windings ) |
- |
100 |
|
- |
| Cl.11.2.7 of Cl.11.2(Printed boards) |
- |
100 |
|
- |
| Cl.11.2.7 i) of Cl.11.2(Printed boards) |
- |
100 |
|
- |
| Cl.11.2.7 i) a) of Cl.11.2(Printed boards) |
- |
100 |
|
- |
| Cl.11.2.7 i) b) of Cl.11.2(Printed boards) |
- |
100 |
|
- |
| Cl.11.2.7 ii) of Cl.11.2(Printed boards) |
- |
100 |
|
- |
| Cl.11.2.7 iii) of Cl.11.2(Printed boards) |
- |
100 |
|
- |
| Cl.11.2.8 of Cl.11.2(Parts not subject to a limit under7.1.1 to 7.1.4) |
- |
100 |
|
- |
| Cl.12.1.1 of Cl.12.1(Requirements) |
- |
100 |
|
- |
| Cl.12.1.2 of Cl.12.1(Bump test ) |
- |
100 |
|
- |
| Cl.12.1.3 of Cl.12.1(Vibration test) |
- |
100 |
|
- |
| Cl.12.1.4 of Cl.12.1(Impact test) |
- |
100 |
|
- |
| Cl.12.1.4 i) of Cl.12.1(Impact test) |
- |
100 |
|
- |
| Cl.12.1.4 ii) of Cl.12.1(Impact test) |
- |
100 |
|
- |
| Cl.12.1.5 of Cl.12.1(Drop test) |
- |
100 |
|
- |
| Cl.12.1.6 of Cl.12.1(Stress relief test) |
- |
100 |
|
- |
| Cl.12.2 of Cl.12(Fixing of actuating elements) |
- |
100 |
|
- |
| Cl.12.3 of Cl.12(Remote control devices held in hand) |
- |
100 |
|
- |
| Cl.12.4 of Cl.12(Drawers ) |
- |
100 |
|
- |
| Cl.12.5 of Cl.12(Antenna coaxial sockets mounted on the apparatus) |
- |
100 |
|
- |
| Cl.12.6 of Cl.12(Telescoping or rod antennas) |
- |
100 |
|
- |
| Cl.12.6.1 of Cl.12.6(General requirements) |
- |
100 |
|
- |
| Cl.12.6.1 i) of Cl.12.6(General requirements) |
- |
100 |
|
- |
| Cl.12.6.2 of Cl.12.6(Physical securement) |
- |
100 |
|
- |
| Cl.12.7 of Cl.12(Apparatus containing coin / button cell batteries) |
- |
100 |
|
- |
| Cl.12.7.3 of Cl.12.7(Tests) |
- |
100 |
|
- |
| Cl.12.7.3.2 of Cl.12.7.3(Stress relief test) |
- |
100 |
|
- |
| Cl.12.7.3.3 of Cl.12.7.3(Battery replacement test) |
- |
100 |
|
- |
| Cl.12.7.3.4 of Cl.12.7.3(Drop test) |
- |
100 |
|
- |
| Cl.12.7.3.5 of Cl.12.7.3(Impact test) |
- |
100 |
|
- |
| Cl.12.7.3.6 of Cl.12.7.3(Crush test) |
- |
100 |
|
- |
| Cl.12.7.4 of Cl.12.7(Compliance) |
- |
100 |
|
- |
| Cl.13.1 of Cl.13(General) |
- |
100 |
|
- |
| Cl.13.2 of Cl.13(Determination of Working voltage) |
- |
100 |
|
- |
| Cl.13.3 of Cl.13(Clearances) |
- |
100 |
|
- |
| Cl.13.3.1 of Cl.13.3(General) |
- |
100 |
|
- |
| Cl.13.3.2 of Cl.13.3(Clearances in circuits conductively connected to the mains) |
- |
100 |
|
- |
| Cl.13.3.3 of Cl.13.3(Clearances in circuits not conductively connected to the mains) |
- |
100 |
|
- |
| Cl.13.3.4 of Cl.13(Measurement of transient voltages) |
- |
100 |
|
- |
| Cl.13.4 a) of Cl.13(Creepage distances ) |
- |
100 |
|
- |
| Cl.13.4 b) of Cl.13(Creepage distances ) |
- |
100 |
|
- |
| Cl.13.4 c) of Cl.13(Creepage distances ) |
- |
100 |
|
- |
| Cl.13.6 a) of Cl.13(Jointed insulation ) |
- |
100 |
|
- |
| Cl.13.6 b) of Cl.13(Jointed insulation ) |
- |
100 |
|
- |
| Cl.13.6 c) of Cl.13(Jointed insulation ) |
- |
100 |
|
- |
| Cl.13.6 d) of Cl.13(Jointed insulation ) |
- |
100 |
|
- |
| Cl.13.7 of Cl.13(Enclosed and sealed parts) |
- |
100 |
|
- |
| Cl.13.8 of Cl.13(Parts filled with insulating compound, meeting the requirements of 8.8) |
- |
100 |
|
- |
| Cl.15.1.2 of Cl.15.1(Design of connectors other than for mains power *) |
- |
100 |
|
- |
| Cl.15.2 of Cl.15(Provisions for protective earthing) |
- |
100 |
|
- |
| Cl.15.3 of Cl.15(Terminals for external flexible cords and for permanent connection to the mains supply*) |
- |
100 |
|
- |
| Cl.15.3.1 of Cl.15.3(Adequate terminals for connection of permanent wiring*) |
- |
100 |
|
- |
| Cl.15.3.2 of Cl.15.3(Reliable connection of non-detachable cords) |
- |
100 |
|
- |
| Cl.15.3.2 i) of Cl.15.3(Not soldered to conductors of a printed circuit board) |
- |
100 |
|
- |
| Cl.15.3.2 ii) of Cl.15.3(Adequate clearances and creepage distances between connections should a wire break away) |
- |
100 |
|
- |
| Cl.15.3.3 of Cl.15.3(Screws and nuts clamping conductors have adequate threads: ISO 261, ISO 262 or similar*) |
- |
100 |
|
- |
| Cl.15.3.4 of Cl.15.3(Conductors adequately fixed (two independent fixings) *) |
- |
100 |
|
- |
| Cl.15.3.5 of Cl.15.3(Terminals allow connection of conductors having appropriate cross-sectional area) |
- |
100 |
|
- |
| Cl.15.3.6 of Cl.15.3(Terminals to 15.3.3 have sizes required by table 16) |
- |
100 |
|
- |
| Cl.15.3.7 of Cl.15.3(Terminals clamp conductors between metal and have adequate pressure) |
- |
100 |
|
- |
| Cl.15.3.7 i) of Cl.15.3(Terminals designed to avoid conductor slipping out when tightened) |
- |
100 |
|
- |
| Cl.15.3.7 ii) of Cl.15.3(Terminals adequately fixed when tightened or loosened (no loosening, wiring not stressed, distances not reduced)) |
- |
100 |
|
- |
| Cl.15.3.8 of Cl.15.3(Terminals carrying a current more than) |
- |
100 |
|
- |
| Cl.15.3.8 i) of Cl.15.3(0.2 A, contact pressure not transmitted by insulating material except ceramic*) |
- |
100 |
|
- |
| Cl.15.3.9 of Cl.15.3(Termination of non-detachable cords: wires terminated near to each other) |
- |
100 |
|
- |
| Cl.15.3.9 i) of Cl.15.3(Terminals located and shielded: test with 8 mm strand) |
- |
100 |
|
- |
| Cl.15.4 of Cl.15(Devices forming a part of the mains plug*) |
- |
100 |
|
- |
| Cl.15.4.1 of Cl.15.4(No undue strain on mains socket-outlets.) |
- |
100 |
|
- |
| Cl.15.4.1 i) of Cl.15.4(Device shall be tested on the equipment as per Fig.11: Torque to be applied : 0.25 Nm (Max)) |
- |
100 |
|
- |
| Cl.15.4.2 of Cl.15.4(Device complies with standard for dimensions of mains plugs) |
- |
100 |
|
- |
| Cl.15.4.3 of Cl.15.4(Device has adequate mechanical strength (tests a,b,c)) |
- |
100 |
|
- |
| Cl.16.2 of Cl.16(Mains cords conductors shall have a nominal cross-sectional area not less than the values given in Table 18, for rated current consumption of the apparatus) |
- |
100 |
|
- |
| Cl.16.3 a) of Cl.16(Flexiblecordsnotcomplyingwith16.1, used for interconnections between separate units of equipment used in combination and carrying hazardous live voltages, have adequate dielectric strength as perCl.10.3) |
- |
100 |
|
- |
| Cl.16.4 of Cl.16(Flexible cords used for connection between equipment have adequate cross-sectional areas to avoid temperature rise under normal and fault conditions) |
- |
100 |
|
- |
| Cl.16.5 a) of Cl.16(Adequate strain relief on external flexible cords) |
- |
100 |
|
- |
| Cl.16.5 b) of Cl.16(Not possible to push cord back into equipment) |
- |
100 |
|
- |
| Cl.16.5 c) of Cl.16(Strain relief device unlikely to damage flexible cord) |
- |
100 |
|
- |
| Cl.16.5 d) of Cl.16(For mains cords of Class I equipment, hazardous live conductors become taut before earth conductor) |
- |
100 |
|
- |
| Cl.16.6 of Cl.16(Apertures for external flexible cord: no risk of damage to the cord during assembly or movement in use) |
- |
100 |
|
- |
| Cl.16.7 a) of Cl.16(Transportable apparatus fitted with detachable cord sets with appliance inlet as perIEC60320-1 or) |
- |
100 |
|
- |
| Cl.16.7 b) of Cl.16(Transportable apparatus shall have a means of stowage to protect the cord) |
- |
100 |
|
- |
| 17.1 a) of Cl.17(Screws are loosened and then tightened with a torque according to table20) |
- |
100 |
|
- |
| Cl.17.1 b) of Cl.17(5 times in the case of screws operating in a thread of metal) |
- |
100 |
|
- |
| Cl.17.1 c) of Cl.17(10 times in the case of screws operating in wood or in a thread in insulating material:) |
- |
100 |
|
- |
| Cl.17.2 of Cl.17(Correct introduction of screws into female threads in non-metallic material) |
- |
100 |
|
- |
| Cl.17.3 a) of Cl.17(Screws or other fixing devices intended to fix Covers, legs, stands or the like, shall be captive in order to prevent replacement during servicing by screws or other fixing devices……) |
- |
100 |
|
- |
| Cl.17.3 b) of Cl.17(Non-captive fixing screws: no hazard when replaced by a screw whose length is 10 times its diameter) |
- |
100 |
|
- |
| Cl.17.4 of Cl.17(No loosening of conductive parts carrying a current > 0.2 A) |
- |
100 |
|
- |
| Cl.17.5 of Cl.17(Contact pressure not transmitted through plastic other than ceramic for connections carrying a current > 0.2 A*) |
- |
100 |
|
- |
| Cl.17.6 of Cl.17(Stranded conductors of flexible supply cords carrying a current > 0.2 A with screw terminals not consolidated by solder *) |
- |
100 |
|
- |
| Cl.17.7 of Cl.17(Cover fixing devices other than screws have adequate strength and their positioning is unambiguous) |
- |
100 |
|
- |
| Cl.17.8 of Cl.17(Detachable legs or stands supplied by the manufacturer of the apparatus shall be delivered with the relevant fixing means *) |
- |
100 |
|
- |
| Cl.17.9 a) of Cl.17(Internal pluggable connections, affecting safety, unlikely to become disconnected) |
- |
100 |
|
- |
| Cl.17.9 b) of Cl.17(By applying a 2N pull force in any direction to the connection, in case of doubt) |
- |
100 |
|
- |
| Cl.19.1 of Cl.19(Stability and mechanical hazards) |
- |
100 |
|
- |
| Cl.19.1 of Cl.19(Stability requirements) |
- |
100 |
|
- |
| Cl.19.2 of Cl.19(Test at 10° to the horizontal) |
- |
100 |
|
- |
| Cl.19.3 of Cl.19(Vertical force test ) |
- |
100 |
|
- |
| Cl.19.4 of Cl.19(Horizontal force test) |
- |
100 |
|
- |
| Cl.19.5 of Cl.19(Test of edges and corners) |
- |
100 |
|
- |
| Cl.19.7 of Cl.19(Wall or ceiling mounting means) |
- |
100 |
|
- |
| Cl.19.7.1 of Cl.19..7(Requirements) |
- |
100 |
|
- |
| Cl.19.7.3 of Cl.19.7(Compliance) |
- |
100 |
|
- |
| Cl.19.6.2 of Cl.19.6(Fragmentation test) |
- |
100 |
|
- |
| Cl.20.1 of Cl.20(Requirements) |
- |
100 |
|
- |
| Cl.19.6.1 of Cl.19.6(Requirements) |
- |
100 |
|
- |
| Cl.20.2.5 of Cl.20.2(Components and parts not covered by 20.2.2, 20.2.3 and 20.2.4) |
- |
100 |
|
- |
| Cl.20.2.5 i) of Cl.20.2(Components and parts not covered by 20.2.2, 20.2.3 and 20.2.4) |
- |
100 |
|
- |
| Cl.20.2.5 ii) of Cl.20.2(Components and parts not covered by 20.2.2, 20.2.3 and 20.2.4) |
- |
100 |
|
- |
| 20(Resistance to fire) |
- |
100 |
|
- |
| Cl.20.3 of Cl.20(Fire enclosure*) |
- |
100 |
|
- |
| Cl.20.3.1 of Cl.20.3(Fire enclosure*) |
- |
100 |
|
- |
| Cl.20.3.2 of Cl.20.3(Fire enclosure*) |
- |
100 |
|
- |
| Cl.20.3.3 of Cl.20.3(Fire enclosure*) |
- |
100 |
|
- |
| Annex-A(Additional requirements for apparatus with protection against splashing water) |
- |
100 |
|
- |
| 3(General requirements) |
- |
100 |
|
- |
| Annex-B(Apparatus to be connected to the TELECOMMUNICATION NETWORKS) |
- |
100 |
|
- |
| Cl.5.5.2 a) of Cl.5.5(Mains powered equipment not exposed to dripping or splashing. Warning concerning objects filled with liquid, etc.) |
- |
100 |
|
- |
| Cl.8.5 ii) of Cl.8(Resistors bridging basic insulation shall complying with 14.1 a) *) |
- |
100 |
|
- |
| Cl.8.11 i) of Cl.8(Noun due reduction of creepage or clearance distances if wires become detached) |
- |
100 |
|
- |
| Cl.8.11 ii) of Cl.8(Vibration test carried out) |
- |
100 |
|
- |
| Cl.9.1 of Cl.9(Testing on the outside) |
- |
100 |
|
- |
| Cl.12.5 a) of Cl.12(Endurance test,) |
- |
100 |
|
- |
| Cl.12.5 b) of Cl.12(Impact test,) |
- |
100 |
|
- |
| Cl.12.5 c) of Cl.12(Torque test) |
- |
100 |
|
- |
| Cl.8.7 v) of Cl.8(Double or reinforced insulation being bridged with a single capacitor or RC-unit complying with 14.3.2 b)) |
- |
100 |
|
- |
| Cl.8.10 of Cl.8(Double insulation between conductors connected to accessible parts and parts connected to the mains) |
- |
100 |
|
- |
| Cl.12.7.1 of Cl.12.7(Coin/button cell batteries with a diameter of 32 mm or less.) |
- |
100 |
|
- |
| Cl.12.7.2 of Cl.12.7(Construction requirementss) |
- |
100 |
|
- |
| Cl.15.1.1 i) of Cl.15.1(Plugs and Sockets*) |
- |
100 |
|
- |
| Cl.15.2 i) of Cl.15(Provisions for protective earthing) |
- |
100 |
|
- |
| Cl.15.2 ii) of Cl.15(Provisions for protective earthing) |
- |
100 |
|
- |
| Cl.15.2 iii) of Cl.15(Provisions for protective earthing) |
- |
100 |
|
- |
| Cl.15.2 iv) of Cl.15(Provisions for protective earthing) |
- |
100 |
|
- |
| Cl.15.2 v) of Cl.15(Provisions for protective earthing) |
- |
100 |
|
- |
| Cl.15.3.2 iii) of Cl.15.3(Wire secured by additional means to the conductor) |
- |
100 |
|
- |
| Cl.16.1 a) of Cl.16(Mains supply flexible cords shall be sheathed type, complying with IEC 60227 for PVC cords or as per IEC 60245 for synthetic rubber cords) |
- |
100 |
|
- |
| Cl.16.1 b) of Cl.16(Non-detachable cords for Class I have green/yellow core for protective earth) |
- |
100 |
|
- |
| Cl.19.1 i) of Cl.19(Stability requirements) |
- |
100 |
|
- |
| Cl.19.6 of Cl.19(Mechanical strength of glass) |
- |
100 |
|
- |
| Cl.8.7 iv) of Cl.8(Double or reinforced insulation being bridged with 2 capacitors or RC-units in series complying with 14.3.2 a)) |
- |
100 |
|
- |
| 16.3b(Cord Bending Test) |
- |
100 |
|
- |
| Cl.15.1.2 i) of Cl.15.1(Design of sockets with symbol of 5.3 b) design *) |
- |
100 |
|
- |
| Cl.11.2.1 of Cl.11.2(Soldered terminations not used as protective mechanism) |
- |
100 |
|
- |
|
29 Apr, 2027 |
- Exclusion: Cl.6 (Hazardous radiations), Cl. 6.2 (Laser Radiation), Cl. 6.1 (Ionizing radiation), Cl. 6.3 (Light Emitting diode(LEDs)), Cl. 14 (Components), Cl.20.2.2 of Cl.20.2 (Electrical components ), CL. 18 (Mechanical strength of picture tubes and protection against the effects of implosion), Cl.20.2.1 a) of Cl.20.2 (Exemption for components contained in an enclosure of material V-0 to IEC60695- 11-10 with openings not exceeding 1 mm in width), Cl.20.2.1 b) of Cl.20.2 (Exemption for small components), Cl.20.2.4 of Cl.20.2 (Printed boards), Cl.20.2 of Cl.20 (Electrical components and mechanical parts), Cl.20.3 of Cl.20 (Fire enclosure*), 8.16/ H 2.2/ H 2.3 (Requirements for insulated winding wires for use without additional interleaved insulation), Cl. 8.16 (Wound Component), Cl. 15 (Internal wires and power cords), Cl. 20.2.4 (Printed Boards), Cl.20.2.5 ii) of Cl.20.2 (Components and parts not covered by 20.2.2, 20.2.3 and 20.2.4), Cl.20.2.4 i) of Cl.20.2 (Printed boards), Cl.8.7 of Cl.8 (Components bridging insulation), Cl.8.7 ii) of Cl.8 (Components bridging basic, supplementary, double or reinforced insulation complying with 14.2 a) or 14.4), Cl.8.7 i) of Cl.8 (Basic insulation bridged by components complying with 14.4.5.3), Cl.8.7 iii) of Cl.8 (Basic and supplementary insulation each being bridged by a capacitor or RC-unit complying with 14.3.2 a)), Cl.8.16 of Cl.8 (Insulated winding wire without additional interleaved insulation), Cl.8.20 of Cl.8 (Bridging components comply with clause 14), Cl. Cl.15.1 of Cl.15 (Plugs and Sockets*), Cl.15.1.3 of Cl.15.1 (Design of terminals and connectors used in output circuits of supply apparatus*), Cl.20.2 of Cl.20 (Electrical components and mechanical parts), Cl.20.2.2 of Cl.20.2 (Electrical components ), Cl.20.2.3 of Cl.20.2 (Internal wiring), Cl.20.2.4 of Cl.20.2 (Printed boards), Cl.20.2.1 b) of Cl.20.2 (Exemption for small components), Cl.8.5 iii) of Cl.8 (Capacitors bridging basic insulation shall complying with 14.2.1 a) *), Annex-L (Additional requirements for electronic flash apparatus for photographic purposes) |
| 11824 |
ABSOLUTE TESTING SERVICES, FARIDABAD
| 8174526
| IS 16046 : Part 1 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 1 Nickel Systems ( Second Revision ) |
- |
60000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
4500 |
|
- |
| 5(General Safety Considerations) |
- |
4500 |
|
- |
| 5.1(General) |
- |
4500 |
|
- |
| 5.2(Insulation and Wiring) |
- |
4500 |
|
- |
| 5.3(Venting) |
- |
4500 |
|
- |
| 5.5(Terminal Contacts) |
- |
4500 |
|
- |
| 5.6(Assembly of Cells into batteries) |
- |
4500 |
|
- |
| 5.7(Quality Plan) |
- |
4500 |
|
- |
| 6(Tyoe Test amd Sample Size) |
- |
4500 |
|
- |
| 7(Specific requirements and tests) |
- |
4500 |
|
- |
| 7.1(Charging procedure for test purposes) |
- |
4500 |
|
- |
| 7.2(Intended Use) |
- |
3500 |
|
- |
| 7.3(Reasonably foreseeable misuse) |
- |
3500 |
|
- |
| 8(Information for safety) |
- |
3500 |
|
- |
| 8.1(General) |
- |
3500 |
|
- |
| 8.2(Small Cell and battery safety information) |
- |
3500 |
|
- |
| 9(Marking) |
- |
2000 |
|
- |
| 9.1(Cell Marking) |
- |
2000 |
|
- |
| 9.2(Battery Marking) |
- |
2000 |
|
- |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
3500 |
|
- |
| 9.4(Other information) |
- |
2800 |
|
- |
| 10(Packaging) |
- |
3500 |
|
- |
| 5.4(Temperature, Voltage and Current Management) |
- |
4000 |
|
- |
|
13 Nov, 2026 |
- - |
| 11825 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 16103 : Part 1 (2012) |
Led modules for general lighting: Part 1 safety requirements |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
1000 |
|
- |
| 8(Terminals) |
- |
1000 |
|
- |
| 9(PROVISION FOR EARTHING) |
- |
1000 |
|
- |
| 10(Protection against accidental contact with live parts) |
- |
1000 |
|
- |
| 11(Mositure Resistance and Insulation) |
- |
3000 |
|
- |
| 12(Electric Strength) |
- |
1000 |
|
- |
| 13(Fault conditions) |
- |
1000 |
|
- |
| 15(Construction) |
- |
3000 |
|
- |
| 16(Creepage distance and clearances) |
- |
1000 |
|
- |
| 17(Screws, current carrying parts and connections) |
- |
3000 |
|
- |
| 18(Resistance to heat, fire and tracking) |
- |
6000 |
|
- |
| 19(Resistance to corrosion) |
- |
2000 |
|
- |
| 21(Heat management) |
- |
1000 |
|
- |
|
29 Apr, 2027 |
- - |
| 11826 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
1000 |
|
- |
| 8(Protection against accidental contact with live parts) |
- |
1000 |
|
- |
| 9(Terminals) |
- |
1000 |
|
- |
| 10(PROVISION FOR EARTHING) |
- |
1000 |
|
- |
| 11(MOISTURE RESISTANCE) |
- |
5000 |
|
- |
| 12(Electric Strength) |
- |
1000 |
|
- |
| 14(Fault conditions) |
- |
1000 |
|
- |
| 15(Transformer heating) |
- |
3000 |
|
- |
| 16(Construction) |
- |
3000 |
|
- |
| 17(Creepage distance and clearances) |
- |
2000 |
|
- |
| 18(Screws, current carrying parts and connections) |
- |
2000 |
|
- |
| 19(Resistance to heat, fire and tracking) |
- |
6000 |
|
- |
| 20(Resistance to corrosion) |
- |
3000 |
|
- |
| 13(Thermal endurance test for winding of ballasts) |
- |
0 |
|
- |
| 4(GENERAL REQUIREMENTS) |
- |
0 |
|
- |
| 5(GENERAL NOTES ON TESTS) |
- |
0 |
|
- |
| 6(CLASSIFICATION) |
- |
0 |
|
- |
| 7(Marking) |
- |
0 |
|
- |
| 8("PROTECTION AGAINST ACCIDENTAL
CONTACT WITH LIVE PARTS") |
- |
0 |
|
- |
| 9(TERMINALS) |
- |
0 |
|
- |
| 10(PROVISIONS FOR PROTECTIVE EARTHING) |
- |
0 |
|
- |
| 11(MOISTURE RESISTANCE AND INSULATION) |
- |
0 |
|
- |
| 12(ELECTRIC STRENGTH) |
- |
0 |
|
- |
| 14(FAULT CONDITIONS) |
- |
0 |
|
- |
| 15(TRANSFORMER HEATING) |
- |
0 |
|
- |
| 16(CONSTRUCTION) |
- |
0 |
|
- |
| 17(CREEPAGE DISTANCES AND CLEARANCES) |
- |
0 |
|
- |
| 18("SCREWS, CURRENT-CARRYING PARTS
AND CONNECTIONS") |
- |
0 |
|
- |
| 19(RESISTANCE TO HEAT, FIRE AND TRACKING) |
- |
0 |
|
- |
| 20(RESISTANCE TO CORROSION) |
- |
0 |
|
- |
|
29 Apr, 2027 |
- Exclusion: Cl.16 (Connector, MOV/VDR, Enclosures, Bridging resistor in primary circuit, (Inductor, Capacitor and RC units, Internal wire, SMPS/Mains Transformer, PCB material, Insulated tape, LED, Opto-coupler, Opto-coupler, EMI/EMC filter, Winding wire, Thin sheet materials, Heat shrinkage sleeve, Fuse, PCB material, RF suppression (X-Y capacitors), Cl. 19 (Metal base PCB for LED, Transparent cover, Bobbin, Terminals) |
| 11827 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
1000 |
|
- |
| 6(Interchangeability) |
- |
1000 |
|
- |
| 7(Protection against accidental contact with live parts) |
- |
3000 |
|
- |
| 8(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
| 9(MECHANICAL STRENGTH) |
- |
3000 |
|
- |
| 10(cap temperature) |
- |
2500 |
|
- |
| 11(Resistance to Heat) |
- |
4000 |
|
- |
| 12(Resistance to Flame and Ignition) |
- |
2000 |
|
- |
| 13(Fault conditions) |
- |
1000 |
|
- |
| 14(Creepage distances and clearances) |
- |
1000 |
|
- |
| 14(Creepage distance and clearances) |
- |
0 |
|
- |
| 4(General requirement and General test requirements) |
- |
0 |
|
- |
| 5(Marking) |
- |
0 |
|
- |
| 6(Interchangeability) |
- |
0 |
|
- |
| 7(Protection against accidental contact with live parts) |
- |
0 |
|
- |
| 8(Strength after humidity treatment) |
- |
0 |
|
- |
| 9(Mechanical strength) |
- |
0 |
|
- |
| 10(Cap temperature rise) |
- |
0 |
|
- |
| 11(Resistance to heat) |
- |
0 |
|
- |
| 12(Resistance to flame and ignition) |
- |
0 |
|
- |
| 13(Fault conditions) |
- |
0 |
|
- |
| 4(GENERAL REQUIREMENT AND GENERAL TEST REQUIREMENTS) |
- |
0 |
|
- |
| 15(Selection of lamps for tests (Sampling)) |
- |
500 |
|
- |
| 16(Condition of compliance) |
- |
500 |
|
- |
| 17(Tests) |
- |
500 |
|
- |
| Annex A(Ovreview of systems composed of LED modules and control gear) |
- |
500 |
|
- |
| Annex B(Lamps with operating position limitations) |
- |
500 |
|
- |
|
29 Apr, 2027 |
- - |
| 11828 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 10322 : Part 5 : Sec 9 (2017) |
Luminaires: Part 5 particular requirements: Sec 9 rope lights |
- |
33000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 21.6(Marking) |
- |
1000 |
|
- |
| 21.7(Construction) |
- |
3000 |
|
- |
| 21.8(Creepage Distance and Clearances) |
- |
2000 |
|
- |
| 21.9(Provision for earthing) |
- |
1000 |
|
- |
| 21.10(Terminals) |
- |
1000 |
|
- |
| 21.11(External & Internal Wiring) |
- |
1000 |
|
- |
| 21.12(Protection against electric shock) |
- |
1000 |
|
- |
| 21.13(Endurance Tests and Thermal Tests) |
- |
8000 |
|
- |
| 21.14(Resistance to Dust & Moisture) |
- |
5000 |
|
- |
| 21.15(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
| 21.16(Resistance to Heat , fire and tracking) |
- |
5000 |
|
- |
| 21.4(General Test Requireements) |
- |
100 |
|
- |
| 21.5(Classification of Luminaires') |
- |
100 |
|
- |
| 21.7.1(General) |
- |
200 |
|
- |
| 21.7.3(Terminals and supply connections) |
- |
200 |
|
- |
| 21.7.4(Control units) |
- |
200 |
|
- |
| 21.7.5(Mechanical strength) |
- |
200 |
|
- |
|
29 Apr, 2027 |
- - |
| 11829 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 10322 : Part 5 : Sec 8 (2013) |
Luminaires: Part 5 particular requirements: Sec 8 emergency lighting |
- |
33100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Classification of Luminaires') |
- |
1000 |
|
- |
| 6.0(Marking) |
- |
1000 |
|
- |
| 8.0(Creepage Distance and Clearances) |
- |
1000 |
|
- |
| 9.0(Provision for earthing) |
- |
1000 |
|
- |
| 10.0(Terminals) |
- |
1000 |
|
- |
| 11.0(External & Internal Wiring) |
- |
1000 |
|
- |
| 12.0(Protection against electric shock) |
- |
1000 |
|
- |
| 13.0(Endurance Tests and Thermal Tests) |
- |
6000 |
|
- |
| 14.0(Resistance to Dust & Moisture) |
- |
4000 |
|
- |
| 15.0(Insulation Resistance and Electric Strength) |
- |
2000 |
|
- |
| 16.0(Resistance to Heat , fire and tracking) |
- |
3000 |
|
- |
| 4(General Test Requireements) |
- |
500 |
|
- |
| 7.0(Construction) |
- |
1000 |
|
- |
| 20.0(BATTERY CHARGERS FOR SELFCONTAINED EMERGENCY LUMINAIRES) |
- |
500 |
|
- |
| 19.0(High Temperature Operation) |
- |
5000 |
|
- |
| 18.0(Changeover Operation) |
- |
1000 |
|
- |
| 22.0(REST MODE AND INIHIBITION MODE FACILITIES) |
- |
1000 |
|
- |
| 21.0(TEST DEVICES FOR EMERGENCY OPERATION) |
- |
100 |
|
- |
| 17.0(Functional Safety) |
- |
2000 |
|
- |
|
29 Apr, 2027 |
- - |
| 11830 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 10322 : Part 5 : Sec 7 (2017) |
Luminaires: Part 5 particular requirements: Sec 7 lighting chains (First Revision) |
- |
33000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 20.6(Marking) |
- |
1000 |
|
- |
| 20.7(Construction) |
- |
3000 |
|
- |
| 20.8(Creepage Distance and Clearances) |
- |
2000 |
|
- |
| 20.9(Provision for earthing) |
- |
1000 |
|
- |
| 20.10(Terminals) |
- |
1000 |
|
- |
| 20.11(External & Internal Wiring) |
- |
1000 |
|
- |
| 20.12(Protection against electric shock) |
- |
1000 |
|
- |
| 20.13(Endurance Tests and Thermal Tests) |
- |
8000 |
|
- |
| 20.14(Resistance to Dust & Moisture) |
- |
5000 |
|
- |
| 20.15(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
| 20.16(Resistance to Heat , fire and tracking) |
- |
6000 |
|
- |
| 20.4(General Test Requireements) |
- |
1000 |
|
- |
| 20.5(Classification of Luminaires') |
- |
1000 |
|
- |
|
29 Apr, 2027 |
- - |
| 11831 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 10322 : Part 5 : Sec 6 (2013) |
Luminaires: Part 5 particular requirements: Sec 6 handlamps |
- |
33000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Marking) |
- |
1000 |
|
- |
| 7.0(Construction) |
- |
3000 |
|
- |
| 8.0(Creepage Distance and Clearances) |
- |
2000 |
|
- |
| 9.0(Provision for earthing) |
- |
1000 |
|
- |
| 10.0(Terminals) |
- |
1000 |
|
- |
| 12.0(Protection against electric shock) |
- |
1000 |
|
- |
| 13.0(Endurance Tests and Thermal Tests) |
- |
8000 |
|
- |
| 14.0(Resistance to Dust & Moisture) |
- |
5000 |
|
- |
| 15.0(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
| 16.0(Resistance to Heat , fire and tracking) |
- |
6000 |
|
- |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
| 11.0(External & Internal Wiring) |
- |
0 |
|
- |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 8.2(Packing -Each Package shall bear the following Particulars) |
- |
0 |
|
- |
|
29 Apr, 2027 |
- - |
| 11832 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 10322 : Part 5 : Sec 2 (2012) |
Luminaires: Part 5 particular requirements: Sec 2 recessed luminaires (First Revision) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Marking) |
- |
1000 |
|
- |
| 7(Construction) |
- |
3000 |
|
- |
| 8(Creepage Distance and Clearances) |
- |
2000 |
|
- |
| 9(Provision for earthing) |
- |
1000 |
|
- |
| 10(Terminals) |
- |
1000 |
|
- |
| 11(External & Internal Wiring) |
- |
1000 |
|
- |
| 12(Protection against electric shock) |
- |
1000 |
|
- |
| 13(Endurance Tests and Thermal Tests) |
- |
8000 |
|
- |
| 14(Resistance to Dust and Moisture) |
- |
5000 |
|
- |
| 15(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
| 16(Resistance to Heat , fire and tracking) |
- |
6000 |
|
- |
| 17(Photometric Test) |
- |
7000 |
|
- |
| 4(General Test Requireements) |
- |
1000 |
|
- |
| 5(Classification of Luminaires') |
- |
1000 |
|
- |
|
29 Apr, 2027 |
- - |
| 11833 |
AADCO TESTING & RESEARCH LABORATORY PVT LTD (F28), GHAZIABAD
| 8141606
| IS 16720 (2018) |
Pulverized Fuel Ash-Cement Bricks- Specification |
ALL |
6500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 and fig.1A &1B(Dimensions- Length (L) ) |
- |
500 |
|
- |
| 4.1 and fig.1A &1B(Dimensions- Width (B) ) |
- |
500 |
|
- |
| 4.1 and fig.1A &1B(Dimensions- Height (H)) |
- |
500 |
|
- |
| 4.1 & 4.3 and fig.1A &1B(Dimensions - Depth) |
- |
500 |
|
- |
| 4.1 and fig.1A &1B(Dimensions) |
- |
500 |
|
- |
| 8.1(GENERAL) |
- |
500 |
|
- |
| 8.3(Density
Annex C of IS 2185 (Part 1)) |
- |
500 |
|
- |
| 8.4 and Table 1(Compressive Strength - Average
IS 3495 (Part 1)) |
- |
500 |
|
- |
| 8.5(Drying Shrinkage
IS 4139) |
- |
500 |
|
- |
| 8.6(Water Absorption
IS 3495 (Part 2)) |
- |
500 |
|
- |
|
26 Jul, 2027 |
- - |
| 11834 |
AADCO TESTING & RESEARCH LABORATORY PVT LTD (F28), GHAZIABAD
| 8141606
| IS 12894 (2002) |
Pulverized fuel ash - Lime bricks - Specification |
all |
6500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(General Requirements) |
- |
500 |
|
- |
| 3.2(General Requirements) |
- |
500 |
|
- |
| 3.3(General Requirements) |
- |
500 |
|
- |
| 3.4(General Requirements) |
- |
500 |
|
- |
| 3.5(General Requirements) |
- |
500 |
|
- |
| 5.1(Dimensions) |
- |
500 |
|
- |
| 5.2(Tolerance) |
- |
500 |
|
- |
| 7.1, Table -1(Average Wet Compressive Strength) |
- |
2000 |
|
- |
| 7.2(Drying Shrinkage) |
- |
500 |
|
- |
| 7.3(Efflorescence Test) |
- |
500 |
|
- |
| 7.4(Water Absorption) |
- |
500 |
|
- |
| 3.1(General Requirements) |
- |
500 |
|
- |
| 3.2(General Requirements) |
- |
500 |
|
- |
| 3.3(General Requirements) |
- |
500 |
|
- |
| 3.4(General Requirements) |
- |
500 |
|
- |
| 3.5(General Requirements) |
- |
500 |
|
- |
| 5.1(Dimensions) |
- |
500 |
|
- |
| 5.2(Tolerance) |
- |
500 |
|
- |
| 7.1, Table -1(Average Wet Compressive Strength) |
- |
2000 |
|
- |
| 7.2(Drying Shrinkage) |
- |
500 |
|
- |
| 7.3(Efflorescence Test) |
- |
500 |
|
- |
| 7.4(Water Absorption) |
- |
500 |
|
- |
|
26 Jul, 2027 |
- - |
| 11835 |
AADCO TESTING & RESEARCH LABORATORY PVT LTD (F28), GHAZIABAD
| 8141606
| IS 2185 : Part 3 (1984) |
Concrete Masonry Units Part 3 Autoclaved Cellular Aerated Concrete Blocks |
ALL |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(SURFACE TEXTURE AND FINISH) |
- |
500 |
|
- |
| 8(Physical requirments) |
- |
1000 |
|
- |
| 8.2(Physical requirments-Dimensions-Length) |
- |
500 |
|
- |
| 8.2(Physical requirments-Dimensions-Height) |
- |
500 |
|
- |
| 8.2(Physical requirments-Dimensions-Width) |
- |
500 |
|
- |
| 8.3(Physical requirments- Block density) |
- |
3000 |
|
- |
| 8.4(Physical requirments- Compressive strength) |
- |
3000 |
|
- |
| 8.5(Thermal Conductivity) |
- |
8000 |
|
- |
| 8.6( Drying Shrinkage ) |
- |
3000 |
|
- |
| 7(SURFACE TEXTURE AND FINISH) |
- |
- |
|
- |
| 8(Physical requirments) |
- |
- |
|
- |
| 8.2(Physical requirments-Dimensions-Length) |
- |
- |
|
- |
| 8.2(Physical requirments-Dimensions-Height) |
- |
- |
|
- |
| 8.2(Physical requirments-Dimensions-Width) |
- |
- |
|
- |
| 8.3(Physical requirments- Block density) |
- |
- |
|
- |
| 8.4(Physical requirments- Compressive strength) |
- |
- |
|
- |
| 8.5(Thermal Conductivity) |
- |
- |
|
- |
| 8.6( Drying Shrinkage ) |
- |
- |
|
- |
|
26 Jul, 2027 |
- - |
| 11836 |
AADCO TESTING & RESEARCH LABORATORY PVT LTD (F28), GHAZIABAD
| 8141606
| IS 15658 (2021) |
Concrete Paving Blocks - Specification ( First Revision ) |
ALL GRADE |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 7.1.1
(General Quality) |
- |
500 |
|
- |
| Clauses 7.1.2 & 9.1.2
(Visual Inspection) |
- |
500 |
|
- |
| Clause 7.1.3
(Colour and Texture) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (i)
(Width, W) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (ii)
(Length, L) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iii)
(Thickness, Th) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iv)
(Aspect Ratio, L/Th) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Width) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Depth) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Thickness of wearing Layer) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Plan Area (Asp)) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (ix)(Deviation from squareness) |
- |
500 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) b)(Water absorption (Average of three test specimens)) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) a)( Indivdual Water absorption) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) b)(Compressive strength (Average of eight test specimens)) |
- |
2500 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) ii)(Wet Abrasion resistance (Average of three test specimens)) |
- |
2000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) ii)(Dry Abrasion resistance (Average of three test specimens)) |
- |
2000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) b)(Average Tensile splitting strength ) |
- |
3000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) b)(Average Flexural strength ) |
- |
4000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 10 cycles) |
- |
2500 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 25 cycles) |
- |
5000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 50 cycles) |
- |
10000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 10 cycles) |
- |
2500 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 25 cycles) |
- |
5000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 50 cycles) |
- |
10000 |
|
- |
| Clause 7.1.1
(General Quality) |
- |
500 |
|
- |
| Clauses 7.1.2 & 9.1.2
(Visual Inspection) |
- |
500 |
|
- |
| Clause 7.1.3
(Colour and Texture) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (i)
(Width, W) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (ii)
(Length, L) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iii)
(Thickness, Th) |
- |
500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iv)
(Aspect Ratio, L/Th) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Width) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Depth) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Thickness of wearing Layer) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Plan Area (Asp)) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (ix)(Deviation from squareness) |
- |
500 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) b)(Water absorption (Average of three test specimens)) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) a)( Indivdual Water absorption) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) b)(Compressive strength (Average of eight test specimens)) |
- |
2500 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) ii)(Wet Abrasion resistance (Average of three test specimens)) |
- |
2000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) ii)(Dry Abrasion resistance (Average of three test specimens)) |
- |
2000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) b)(Average Tensile splitting strength ) |
- |
3000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) b)(Average Flexural strength ) |
- |
4000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 10 cycles) |
- |
2500 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 25 cycles) |
- |
5000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 50 cycles) |
- |
10000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 10 cycles) |
- |
2500 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 25 cycles) |
- |
5000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 50 cycles) |
- |
10000 |
|
- |
|
26 Jul, 2027 |
- - |
| 11837 |
National Test House (NR) - NTH, Ghaziabad
| 8101304
| IS 14255 (1995) |
Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.1 a) i)(Tests on phase/street light conductor: tensile test - Test method IS10810:Part 2) |
- |
250 |
|
- |
| 10.1 a) ii)(Wrapping test - 10810: Part 3) |
- |
250 |
|
- |
| 10.1 a) iii)(Resistance test - IS10810: Part 5) |
- |
250 |
|
- |
| 10.1 b) i)(Test on messenger conductor: Breaking load - IS 10810: Part 2) |
- |
250 |
|
- |
| 10.1 b) ii)(Test on messenger conductor: Elongation test - Cl 11.3) |
- |
250 |
|
- |
| 10.1 b) iii)(Test on messenger conductor: Resistance test - IS 10810: Part 5) |
- |
250 |
|
- |
| 10.1 c) i)(Physical tests for XLPE Insulation:
Tensile strength - IS 10810: Part 7) |
- |
250 |
|
- |
| 10.1 c) i)(Physical tests for XLPE Insulation:
elongation at break - IS 10810: part 7) |
- |
250 |
|
- |
| 10.1 c) ii)(Ageing in air oven : Tensile strength variation - IS 10810:Part 11) |
- |
250 |
|
- |
| 10.1 c) ii)(Ageing in air oven : Elongation variation- IS 10810: Part 11) |
- |
250 |
|
- |
| 10.1 c) iii)(Hot set test: Elongation under load - IS 10810: Part 30) |
- |
250 |
|
- |
| 10.1 c) iii)(Hot set test: Permanent elongation (set) after cooling - IS 10810: Part 30) |
- |
250 |
|
- |
| 10.1 c) iv)(Shrinkage test : Crack Observed - 10810:Part 12) |
- |
250 |
|
- |
| 10.1 c) iv)(Shrinkage test : Shrinkage - 10810:Part 12) |
- |
250 |
|
- |
| 10.1 c) v)(Water ahsorption (Gravimetric) - IS 10810: Part 33 ) |
- |
250 |
|
- |
| 10.1 d) i)(Physical test for PE insulation:
Tensile strength - IS 10810: Part 7 ) |
- |
250 |
|
- |
| 10.1 d) i)(Physical test for PE insulation: elongation at break - IS 10810: Part 7) |
- |
250 |
|
- |
| 10.1 d) ii)(Melt flow index- IS 10810: Part 23) |
- |
250 |
|
- |
| 10.1 d) iv)(Vicat softening point -IS 10810: Part 22) |
- |
250 |
|
- |
| 10.1 d) v)(Environmental stress cracking -IS 10810:Part29) |
- |
250 |
|
- |
| 10.1 f)(Insulation resistance (Volume resistivity) test a) volume resistivity at 27°C - IS 10810: Part 43) |
- |
250 |
|
- |
| 10.1 f)(Insulation resistance (Volume resistivity) test b) volume resistivity at 70°C - IS 10810: Part 43) |
- |
250 |
|
- |
| 10.1 g)(High voltage test - IS10810:Part 45) |
- |
250 |
|
- |
| 6.4(size of street lighting conductor) |
- |
250 |
|
- |
| 6.5(Size of messenger conductor ) |
- |
250 |
|
- |
| 4.1(Phase/Street Lighting conductor) |
- |
250 |
|
- |
| 4.2(Messenger (Neutral Conductor or Otherwise)) |
- |
250 |
|
- |
| 6.2(No of strands) |
- |
250 |
|
- |
| 5.1(Insulation) |
- |
250 |
|
- |
| 6.1(Flexibility class) |
- |
250 |
|
- |
| 6.2(Compactness) |
- |
250 |
|
- |
| 6.2(Surface) |
- |
250 |
|
- |
| 6.3(Protective barrier) |
- |
250 |
|
- |
| 6.6(Direction of outer layer) |
- |
250 |
|
- |
| 7.2( Thickness of insulation) |
- |
250 |
|
- |
| 7.3(Tolerance on thickness of insulation ) |
- |
250 |
|
- |
| 7.5(Colour of the insulation ) |
- |
250 |
|
- |
| 9.1(Assembly (Laying up)) |
- |
250 |
|
- |
| 9.3(Direction of lay) |
- |
250 |
|
- |
| 11.4(Bending Test on the Completed Cable ( Optional) ) |
- |
250 |
|
- |
|
26 Oct, 2028 |
- - |
| 11838 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Marking) |
- |
1000 |
|
- |
| 7.0(Construction) |
- |
3000 |
|
- |
| 8.0(Creepage Distance and Clearances) |
- |
2000 |
|
- |
| 9.0(Provision for earthing) |
- |
1000 |
|
- |
| 10.0(Terminals) |
- |
1000 |
|
- |
| 11.0(External & Internal Wiring) |
- |
1000 |
|
- |
| 12.0(Protection against electric shock) |
- |
1000 |
|
- |
| 13.0(Endurance Tests and Thermal Tests) |
- |
8000 |
|
- |
| 14.0(Resistance to Dust & Moisture) |
- |
5000 |
|
- |
| 15.0(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
| 16.0(Resistance to Heat , fire and tracking) |
- |
6000 |
|
- |
| 17.0(Photometric Test) |
- |
7000 |
|
- |
| 4(General Test Requireements) |
- |
1000 |
|
- |
| 5(Classification of Luminaires') |
- |
1000 |
|
- |
|
29 Apr, 2027 |
- Exclusion: Cl.7.0 (Construction/ UV radiation) |
| 11839 |
ABSOLUTE TESTING SERVICES, FARIDABAD
| 8174526
| IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
- |
19200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
3500 |
|
- |
| 7(Marking and instructions) |
- |
3500 |
|
- |
| 8(Protection against live parts) |
- |
3500 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
3500 |
|
- |
| 11(HEATING) |
- |
3500 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
3500 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
3500 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
3500 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
3500 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
3500 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
3500 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
3500 |
|
- |
| 22(CONSTRUCTION) |
- |
3500 |
|
- |
| 23(INTERNAL WIRING) |
- |
3500 |
|
- |
| 24(COMPONENTS) |
- |
3500 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
3500 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
3500 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
3500 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
3500 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
3500 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
3500 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
3500 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
3500 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
2500 |
|
- |
|
13 Nov, 2026 |
- - |
| 11840 |
CIPET, Hyderabad
| 6111634
| IS 16703 (2017) |
Textiles - High density polyethylene (HDPE) polypropylene (PP) woven sacks for packaging of 25 kg polymer materials - Specification |
High density polyethylene (HDPE) polypropylene (PP) wo |
18580 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Mass of Bale) |
- |
250 |
|
- |
| 5.2 Table 1(Dimensions) |
- |
250 |
|
- |
| 5.2 Table 1(Mass of sack, Gusseted type, g - IS 1964) |
- |
250 |
|
- |
| 5.2 Table 1(Ends per dm) |
- |
250 |
|
- |
| 5.2 Table 1(Picks per dm) |
- |
250 |
|
- |
| 5.2 Table 1(Average breaking strength of fabric [Ravelled strip
method, 325 mm × 70mm1)] Min, N) (kgf): - IS 1969 (Part 1)) |
- |
2200 |
|
- |
| 5.2 Table 1(Breaking strength of bottom seam (Ravelled strip
method), Min, N) (kgf) - IS 9030) |
- |
1100 |
|
- |
| 5.2 Table 1(Drop impact strength) |
- |
1100 |
|
- |
| (Clauses 4.2, 5.1, 5.2, 5.3 and 5.4) Table 1 (Ash Content ,a) For UV stabilized sacks) |
- |
950 |
|
- |
|
23 Feb, 2027 |
- Including w.e.f. 28.10.2024 |
| 11841 |
Stellar Test House, Noida
| 8171606
| IS 2185 : Part 1 (2005) |
Concrete masonry units - Specification: Part 1 hollow and solid concrete blocks (Third Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.2 & 4.2(PHYSICAL REQUIREMENTS-Nominal Dimensions 1.Length 2.Hight 3. Width) |
- |
1000 |
|
- |
| 9.2 & 4.2.3(Nominal Dimensions-variation in the length of units ) |
- |
0 |
|
- |
| 9.2 & 4.2.3(Nominal Dimensions -variation in height and width of units ) |
- |
1000 |
|
- |
| 9.2 & 4.2.4, Table-1(Nominal Dimensions-thickness of
the face shell) |
- |
0 |
|
- |
| 9.2 & 4.2.4, Table-1(Nominal Dimensions-thickness of
the Web shell) |
- |
1000 |
|
- |
| 9.3 & 5.1 & 5.2 Table 2(PHYSICAL REQUIREMENTS-Blocks Density - 1.Hollow (Open and Closed Cavity) Concrete Block- Grade Aor Grade B 2.Solid Concrete Block — Grade C) |
- |
1000 |
|
- |
| 9.4- Table 2(PHYSICAL REQUIREMENTS - Compressive Strength 1.Minimum Average Compressive Strength of Units 2.Minimum Average Compressive Strength of Individual Unit) |
- |
5000 |
|
- |
| 9.5(PHYSICAL REQUIREMENTS -Water Absorption) |
- |
1500 |
|
- |
| 9.6(PHYSICAL REQUIREMENTS -Drying Shrinkage) |
- |
2500 |
|
- |
| 9.7(PHYSICAL REQUIREMENTS -Moisture Movement) |
- |
2000 |
|
- |
| 15(Marking) |
- |
0 |
|
- |
| 9.2 & 4.2(PHYSICAL REQUIREMENTS-Nominal Dimensions 1.Length 2.Hight 3. Width) |
- |
0 |
|
- |
| 9.2 & 4.2.3(Nominal Dimensions-variation in the length of units ) |
- |
0 |
|
- |
| 9.2 & 4.2.3(Nominal Dimensions -variation in height and width of units ) |
- |
0 |
|
- |
| 9.2 & 4.2.4, Table-1(Nominal Dimensions-thickness of
the face shell) |
- |
0 |
|
- |
| 9.2 & 4.2.4, Table-1(Nominal Dimensions-thickness of
the Web shell) |
- |
0 |
|
- |
| 9.3 & 5.1 & 5.2 Table 2(PHYSICAL REQUIREMENTS-Blocks Density - 1.Hollow (Open and Closed Cavity) Concrete Block- Grade Aor Grade B 2.Solid Concrete Block — Grade C) |
- |
0 |
|
- |
| 9.4- Table 2(PHYSICAL REQUIREMENTS - Compressive Strength 1.Minimum Average Compressive Strength of Units 2.Minimum Average Compressive Strength of Individual Unit) |
- |
0 |
|
- |
| 9.5(PHYSICAL REQUIREMENTS -Water Absorption) |
- |
0 |
|
- |
| 9.6(PHYSICAL REQUIREMENTS -Drying Shrinkage) |
- |
0 |
|
- |
| 9.7(PHYSICAL REQUIREMENTS -Moisture Movement) |
- |
0 |
|
- |
| 15(Marking) |
- |
0 |
|
- |
| 9.2 & 4.2(PHYSICAL REQUIREMENTS-Nominal Dimensions 1.Length 2.Hight 3. Width) |
- |
0 |
|
- |
| 9.2 & 4.2.3(Nominal Dimensions-variation in the length of units ) |
- |
0 |
|
- |
| 9.2 & 4.2.3(Nominal Dimensions -variation in height and width of units ) |
- |
0 |
|
- |
| 9.2 & 4.2.4, Table-1(Nominal Dimensions-thickness of
the face shell) |
- |
0 |
|
- |
| 9.2 & 4.2.4, Table-1(Nominal Dimensions-thickness of
the Web shell) |
- |
0 |
|
- |
| 9.3 & 5.1 & 5.2 Table 2(PHYSICAL REQUIREMENTS-Blocks Density - 1.Hollow (Open and Closed Cavity) Concrete Block- Grade Aor Grade B 2.Solid Concrete Block — Grade C) |
- |
0 |
|
- |
| 9.4- Table 2(PHYSICAL REQUIREMENTS - Compressive Strength 1.Minimum Average Compressive Strength of Units 2.Minimum Average Compressive Strength of Individual Unit) |
- |
0 |
|
- |
| 9.5(PHYSICAL REQUIREMENTS -Water Absorption) |
- |
0 |
|
- |
| 9.6(PHYSICAL REQUIREMENTS -Drying Shrinkage) |
- |
0 |
|
- |
| 9.7(PHYSICAL REQUIREMENTS -Moisture Movement) |
- |
0 |
|
- |
| 15(Marking) |
- |
0 |
|
- |
|
26 Sep, 2028 |
- Included w.e.f. 28.03.2024 |
| 11842 |
INDIAN TESTING LABORATORY PRIVATE LIMITED, GREATER NOIDA
| 8171306
| IS 14333 (2022) |
Polyethylene Pipes for Sewerage and Industrial Chemicals and Effluent � Specification (First Revision) |
PE63,PE80,PE100 |
27500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2.1,T2("Base Density
(At 27°C Temp.)-IS 7328:2020 ") |
- |
750 |
|
- |
| 5.2.1,T2(Melt Flow Rate (At 190°C /5kg)-IS 2530:1963) |
- |
1200 |
|
- |
| 5.2.1,T2(Thermal Stability(Oxidation Induction Time)-IS 4984:2016(Annexure-B)) |
- |
2500 |
|
- |
| 5.2.1,T2("Volatile Matter- IS 4984:2016
(Annexure-C)") |
- |
1000 |
|
- |
| 5.2.1,T2("Water Content-IS 4984:2016
(Annexure-D)") |
- |
1000 |
|
- |
| 5.2.1.1, T2(Compound Density-IS 7328:2020) |
- |
750 |
|
- |
| 5.2.1.1, T2("Compound carbon black -IS 2530:1963
content") |
- |
1200 |
|
- |
| 5.2.1.1, T2(Compound Toluene extract - Any Method) |
- |
1000 |
|
- |
| 5.2.1.1, T2(Compound maximum volatile matter -IS 4984:2016 (Annexure-C)) |
- |
1000 |
|
- |
| 5.2.1.1, T2(Compound carbon black particle size- Any Method) |
- |
1200 |
|
- |
| 5.2.1.1, T2(Compound ash content - Any Method) |
- |
1200 |
|
- |
| 5.2.1.1, T2("Compound carbon black -IS 2530:1963
dispersion") |
- |
1200 |
|
- |
| 5.3(Density of Higher olefin - IS 7328:2020) |
- |
750 |
|
- |
| 5.3(Olefin Constituents- 14333-2022) |
- |
1000 |
|
- |
| 5.3(Loading of Carbon Black - IS 2530:1963) |
- |
1200 |
|
- |
| 5.3(Ash content- Any Method) |
- |
1200 |
|
- |
| 5.3(Toluene extract - Any Method) |
- |
1000 |
|
- |
| 5.3("Maximum volatile matter -IS 4984:2016
(Annexure-C)") |
- |
1000 |
|
- |
| 5.3(Carbon black particle size - Any Method) |
- |
750 |
|
- |
| 6(Pipe Description - IS 14333-2022) |
- |
100 |
|
- |
| 6.2(Colour- IS 14333-2022) |
- |
250 |
|
- |
| 7.1(Visual Appearance- IS 14333-2022) |
- |
250 |
|
- |
| 7.2(Length- IS 14333-2022) |
- |
100 |
|
- |
| 7.4,T3 of IS 4984(Outside Diameter-IS 4984-2016) |
- |
100 |
|
- |
| 7.4,T4 of IS 4984(wall Thickness-IS 4984-2016) |
- |
100 |
|
- |
| 7.4,T3 of IS 4984(Ovality-IS 4984-2016) |
- |
100 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 27 oC , Test Period - 100 hrs.-IS 4984-2016 (Annexure-E)) |
- |
1500 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
2500 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 165 hrs.-IS 4984-2016 (Annexure-E)) |
- |
2500 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 1000 hrs.-IS 4984-2016 (Annexure-E)) |
- |
7500 |
|
- |
| 8.1.2, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
2500 |
|
- |
| 8.2("Longitudinal Reversion Test - IS 4984-2016
(Annexure-F)") |
- |
1200 |
|
- |
| 8.3(Carbon black content- IS 2530-1963) |
- |
1200 |
|
- |
| 8.3(Carbon black content Dispersion- IS 2530-1963) |
- |
1000 |
|
- |
| 8.4(Melt Flow rate(Temperature - 190oC,Mass 5kg)-IS 2530-1963) |
- |
1200 |
|
- |
| 8.5(Oxidation Induction Time -IS 4984:2016(Annexure-B)) |
- |
2500 |
|
- |
| 8.6(Density-IS 7328:2020) |
- |
750 |
|
- |
| 8.7("Tensile Strength for Butt Fusion - IS 4984-2016
(Annexure-G)") |
- |
1200 |
|
- |
| 8.8,T5("Elongation -IS 4984-2016
(Annexure-H)") |
- |
1000 |
|
- |
| 8.9(Slow Crack Growth Rate{Internal Pressure creep Rupture test, Temperature - 80±1 oC , Test Pressure – 0.80MPa, Test Period - 500 hrs.-IS 4984-2016 (Annexure-E &J)) |
- |
3500 |
|
- |
| 5.2.1,T2("Base Density
(At 27°C Temp.)-IS 7328:2020 ") |
- |
- |
|
- |
| 5.2.1,T2(Melt Flow Rate (At 190°C /5kg)-IS 2530:1963) |
- |
- |
|
- |
| 5.2.1,T2(Thermal Stability(Oxidation Induction Time)-IS 4984:2016(Annexure-B)) |
- |
- |
|
- |
| 5.2.1,T2("Volatile Matter- IS 4984:2016
(Annexure-C)") |
- |
- |
|
- |
| 5.2.1,T2("Water Content-IS 4984:2016
(Annexure-D)") |
- |
- |
|
- |
| 5.2.1.1, T2(Compound Density-IS 7328:2020) |
- |
- |
|
- |
| 5.2.1.1, T2("Compound carbon black -IS 2530:1963
content") |
- |
- |
|
- |
| 5.2.1.1, T2(Compound Toluene extract - Any Method) |
- |
- |
|
- |
| 5.2.1.1, T2(Compound maximum volatile matter -IS 4984:2016 (Annexure-C)) |
- |
- |
|
- |
| 5.2.1.1, T2(Compound carbon black particle size- Any Method) |
- |
- |
|
- |
| 5.2.1.1, T2(Compound ash content - Any Method) |
- |
- |
|
- |
| 5.2.1.1, T2("Compound carbon black -IS 2530:1963
dispersion") |
- |
- |
|
- |
| 5.3(Density of Higher olefin - IS 7328:2020) |
- |
- |
|
- |
| 5.3(Olefin Constituents- 14333-2022) |
- |
- |
|
- |
| 5.3(Loading of Carbon Black - IS 2530:1963) |
- |
- |
|
- |
| 5.3(Ash content- Any Method) |
- |
- |
|
- |
| 5.3(Toluene extract - Any Method) |
- |
- |
|
- |
| 5.3("Maximum volatile matter -IS 4984:2016
(Annexure-C)") |
- |
- |
|
- |
| 5.3(Carbon black particle size - Any Method) |
- |
- |
|
- |
| 6(Pipe Description - IS 14333-2022) |
- |
- |
|
- |
| 6.2(Colour- IS 14333-2022) |
- |
- |
|
- |
| 7.1(Visual Appearance- IS 14333-2022) |
- |
- |
|
- |
| 7.2(Length- IS 14333-2022) |
- |
- |
|
- |
| 7.4,T3 of IS 4984(Outside Diameter-IS 4984-2016) |
- |
- |
|
- |
| 7.4,T4 of IS 4984(wall Thickness-IS 4984-2016) |
- |
- |
|
- |
| 7.4,T3 of IS 4984(Ovality-IS 4984-2016) |
- |
- |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 27 oC , Test Period - 100 hrs.-IS 4984-2016 (Annexure-E)) |
- |
- |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
- |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 165 hrs.-IS 4984-2016 (Annexure-E)) |
- |
- |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 1000 hrs.-IS 4984-2016 (Annexure-E)) |
- |
- |
|
- |
| 8.1.2, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
- |
|
- |
| 8.2("Longitudinal Reversion Test - IS 4984-2016
(Annexure-F)") |
- |
- |
|
- |
| 8.3(Carbon black content- IS 2530-1963) |
- |
- |
|
- |
| 8.3(Carbon black content Dispersion- IS 2530-1963) |
- |
- |
|
- |
| 8.4(Melt Flow rate(Temperature - 190oC,Mass 5kg)-IS 2530-1963) |
- |
- |
|
- |
| 8.5(Oxidation Induction Time -IS 4984:2016(Annexure-B)) |
- |
- |
|
- |
| 8.6(Density-IS 7328:2020) |
- |
- |
|
- |
| 8.7("Tensile Strength for Butt Fusion - IS 4984-2016
(Annexure-G)") |
- |
- |
|
- |
| 8.8,T5("Elongation -IS 4984-2016
(Annexure-H)") |
- |
- |
|
- |
| 8.9(Slow Crack Growth Rate{Internal Pressure creep Rupture test, Temperature - 80±1 oC , Test Pressure – 0.80MPa, Test Period - 500 hrs.-IS 4984-2016 (Annexure-E &J)) |
- |
- |
|
- |
|
15 Aug, 2028 |
- Revised Version of IS 14333:2022. Included w.e.f. 07.03.2023 |
| 11843 |
CAHS,TANUVAS, CHENNAI
| 6168114
| IS 1664 (2002) |
Mineral mixtures for supplementing cattle feeds - Specification (Fourth Revision) |
- |
1400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.2(Bacillus anthracis) |
- |
1400 |
|
- |
|
- |
- - |
| 11844 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 10322 : Part 5 : Sec 5 (2013) |
Luminaires: Part 5 particular requirements: Sec 5 floodlights (First Revision) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.0(Construction) |
- |
3000 |
|
- |
| 6.0(Marking) |
- |
1000 |
|
- |
| 8.0(Creepage Distance and Clearances) |
- |
2000 |
|
- |
| 9.0(Provision for earthing) |
- |
1000 |
|
- |
| 12.0(Protection against electric shock) |
- |
1000 |
|
- |
| 13.0(Endurance Tests and Thermal Tests) |
- |
8000 |
|
- |
| 14.0(Resistance to Dust & Moisture) |
- |
5000 |
|
- |
| 15.0(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
| 16.0(Resistance to Heat , fire and tracking) |
- |
6000 |
|
- |
| 17.0(Photometric Test) |
- |
7000 |
|
- |
| 4(General Test Requireements) |
- |
1000 |
|
- |
| 5(Classification of Luminaires') |
- |
1000 |
|
- |
| 10.0(Terminals) |
- |
1000 |
|
- |
| 11.0(External & Internal Wiring) |
- |
1000 |
|
- |
|
29 Apr, 2027 |
- - |
| 11845 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 10322 : PART 5 : SEC 3 (2012) |
Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.0(Construction) |
- |
3000 |
|
- |
| 8.0(Creepage Distance and Clearances) |
- |
2000 |
|
- |
| 9.0(Provision for earthing) |
- |
1000 |
|
- |
| 10.0(Terminals) |
- |
1000 |
|
- |
| 11.0(External & Internal Wiring) |
- |
1000 |
|
- |
| 12.0(Protection against electric shock) |
- |
1000 |
|
- |
| 13.0(Endurance Tests and Thermal Tests) |
- |
8000 |
|
- |
| 14.0(Resistance to Dust & Moisture) |
- |
5000 |
|
- |
| 15.0(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
| 16.0(Resistance to Heat , fire and tracking) |
- |
6000 |
|
- |
| 17.0(Photometric Test) |
- |
7000 |
|
- |
| 6.0(Marking) |
- |
1000 |
|
- |
| 5(Classification of Luminaires') |
- |
1000 |
|
- |
| 4(General Test Requireements) |
- |
1000 |
|
- |
|
29 Apr, 2027 |
- - |
| 11846 |
CIPET, Hyderabad
| 6111634
| IS 17216 (2019) |
Polyethylene Mulch Films for Agriculture and Horticulture • Specification |
Polyethylene Mulch Films for Agriculture |
17950.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.1(Density) |
- |
500 |
|
- |
| 5.1.2(Melt Flow Index) |
- |
1100 |
|
- |
| 5.1.4(Carbon black, Density) |
- |
925 |
|
- |
| 5.1.4(Carbon black, Toluene extract) |
- |
925 |
|
- |
| 5.1.4(Carbon black, Volatile matter) |
- |
925 |
|
- |
| 5.1.4(Carbon black, particle size) |
- |
925 |
|
- |
| 5.1.4(Carbon black, Tint strength) |
- |
925 |
|
- |
| 5.2.1(Visual Appearance) |
- |
300 |
|
- |
| 5.2.4(Odour) |
- |
250 |
|
- |
| 5.3.1.1(Tolerance on thickness) |
- |
250 |
|
- |
| 5.3.1.2(Tolerance on width) |
- |
250 |
|
- |
| 5.3.2(Impact Strength) |
- |
1100 |
|
- |
| 5.3.2, Table 1(Nominal Film Thickness) |
- |
250 |
|
- |
| 5.3.2, Table 1(Impact Failure Mass) |
- |
1100 |
|
- |
| 5.3.3(Tensile Strength at Break) |
- |
2200 |
|
- |
| 5.3.4(Elongation at Break) |
- |
2200 |
|
- |
| 5.3.5(Coefficient of Friction) |
- |
850 |
|
- |
| 5.3.6(Elmendorf Tear Strength) |
- |
2200 |
|
- |
| 5.3.7(Opacity) |
- |
575 |
|
- |
| 5.4, Table 2(Carbon black, percent) |
- |
925 |
|
- |
| 5.4, Table 2(Ash content, percent) |
- |
950 |
|
- |
| 5.4, Table 2(Carbon black dispersion) |
- |
700 |
|
- |
| 5.5(Service Life) |
- |
75860 |
|
- |
|
23 Feb, 2027 |
- Including w.e.f. 28.10.2024 |
| 11847 |
CIPET, Hyderabad
| 6111634
| IS 16190 (2014) |
Agro textiles - High density polyethylene (HDPE) laminated woven lay flat tube for irrigation purpose - Specification |
HDPE laminated woven lay flat tube for irrigation |
114531 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.
Table 2 v)
IS 14714
(Abrasion resistance :
Loss in breaking strength shall not be more than 15 percent) |
- |
875 |
|
- |
| 6.
Table 2 ix) a)
IS 7016(Part 8)
(Oven method)
(Accelerated ageing test for 72 h
at 70 ± 1°C:
Loss in breaking strength shall not be more than 15 percent
Wrap) |
- |
1800 |
|
- |
| 6.
Table 2 ix) b)
IS 7016(Part 8)
(Oven method)
(Accelerated ageing test for 72 h
at 70 ± 1°C:
Loss in breaking strength shall not be more than 1 5 percent
Weft) |
- |
1800 |
|
- |
| 6.
Table 2 iii)
IS 1969 (Part 1)
( Elongation at break) |
- |
1100 |
|
- |
| 6.5( Length :
Unless specified otherwise, the standard length shall be 30 m. A tolerance of +5 percent shall be permitted on the length prescribed for the lay flat tube by the
purchaser. No negative tolerance shall be permitted) |
- |
250 |
|
- |
| 5,5.3
Table 1.(MANUFACTURE
The laminated HDPE woven fabric is to be formed in to lay flat tube of the required inside diameter using a heat sealing process keeping the minimum overlap
as specified in Table 1.) |
- |
250 |
|
- |
| 6.
Table 2 vi) a)
IS 14293
( Trapezoid tear strength:
Wrap) |
- |
1100 |
|
- |
| 6.
Table 2 vi) b)
IS 14293
( Trapezoid tear strength :
Weft) |
- |
1100 |
|
- |
| 6.
Table 2 i)
IS 1964
(Mass) |
- |
250 |
|
- |
| 6.
Table 2 vii)
Annex C
(Puncture strength) |
- |
1100 |
|
- |
| 6.
Table 2 iv) b)
Annex B(Retention of breaking strength after
UV exposure of 500 h :
weft
85 percent of original actual value (fabric)) |
- |
1100 |
|
- |
| 6.
Table 2 ii) b)
IS 1969 (Part 1)
( Breaking strength before UV exposure :
Weft) |
- |
1100 |
|
- |
| 6.
Table 2 iv) a)
Annex B(Retention of breaking strength after
UV exposure of 500 h :
Wrap
85 percent of original actual value (fabric)) |
- |
1100 |
|
- |
| 6.
Table 2 ii) a)
IS 1969 (Part 1)
( Breaking strength before UV exposure :
Wrap) |
- |
1100 |
|
- |
| 4,4.1
IS 6192( MATERIALS
HDPE Tapes) |
- |
500 |
|
- |
| 4.2
IS 6899(MATERIALS
HDPE Fabric) |
- |
250 |
|
- |
| 6.
Table 2 viii)
Annex D
( Environmental stress cracking test :
) |
- |
1200 |
|
- |
| 6.
Table 2 x)
Annex E
(Cold cracking resistance test at –5°C) |
- |
1100 |
|
- |
| 6.1
Table 1(Internal Diameter :
The inside diameter of the lay flat tube shall be as given in Table 1. The internal diameter of the lay flat tube shall be measured by a suitable conical plug gauge and
shall conform to the tolerance specified in Table 1) |
- |
250 |
|
- |
| 6.2(Workmanship) |
- |
300 |
|
- |
| 6.3,6.3.1(Hydrostatic Burst Pressure Test) |
- |
1000 |
|
- |
| 6.4 , 6.4.1(Proof Pressure Tes) |
- |
1000 |
|
- |
| 6.6(Kink Test :) |
- |
1100 |
|
- |
| 6.7
IS 1969 (Part 1)(Welded Seam Strength Before UV
Exposure :
When a sample of fabric with seam cut from the lay
flat tube is tested for welded seam strength as per the
method specified in IS 1969 (Part 1), welded seam
strength before UV exposure shall be not less than the
80 percent of the original actual fabric strength) |
- |
1100 |
|
- |
| 6.8
Annex B and
IS 1969 (Part 1)(Welded Seam Strength After UV Exposure:
When a sample of fabric with seam cut from the lay
flat tube is tested for welded seam strength as per the
method specified in Annex B and IS 1969 (Part 1), the
loss in welded seam strength after UV exposure shall
be not more than 15 percent) |
- |
1100 |
|
- |
|
23 Feb, 2027 |
- Including w.e.f. 28.10.2024 |
| 11848 |
CIPET, Hyderabad
| 6111634
| IS 17358 : Part 1 (2020) |
Agro textiles “ Fencing nets for agriculture and horticulture purposes “ Specification Part 1 Fencing nets made from extruded polymer mesh |
Fencing nets made from extruded polymer mesh |
17948 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4, table 1,2,3(MATERIALS) |
- |
5700 |
|
- |
| 5.2(Colour) |
- |
250 |
|
- |
| (ii)(Mesh Size, Traverse Direction) |
- |
250 |
|
- |
| (iii)(Mesh Size, Cross Direction) |
- |
250 |
|
- |
| (vi)(Length) |
- |
250 |
|
- |
| (vi)(Width) |
- |
250 |
|
- |
| (vii) a(Tensile Strength before UV exposure, Machine Direction) |
- |
1100 |
|
- |
| (ix) a(Tensile Strength after UV exposure, Machine Direction) |
- |
1100 |
|
- |
| (vii) b(Tensile Strength before UV exposure, Traverse Direction) |
- |
1100 |
|
- |
| (ix) b(Tensile Strength after UV exposure, Traverse Direction) |
- |
1100 |
|
- |
| (viii) a(Elongation before UV exposure, Machine Direction) |
- |
1100 |
|
- |
| (viii) b(Elongation before UV exposure, Traverse Direction) |
- |
1100 |
|
- |
|
23 Feb, 2027 |
- Including w.e.f. 28.10.2024 |
| 11849 |
ABSOLUTE TESTING SERVICES, FARIDABAD
| 8174526
| IS 302 : Part 2 : Sec 14 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision) |
- |
18125 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
3500 |
|
- |
| 6(Classification- IS 302-1) |
- |
3500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3500 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
3500 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
3500 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
3500 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
3500 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
3500 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
3500 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
3500 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
3500 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
3500 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
3500 |
|
- |
| 7.101(Marking) |
- |
3500 |
|
- |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
3500 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
3500 |
|
- |
| 11(Heating, IS 302-1) |
- |
3500 |
|
- |
| 11(Heating, IS 302-1) |
- |
3500 |
|
- |
| 11(Heating, IS 302-1) |
- |
3500 |
|
- |
| 11(Heating, IS 302-1) |
- |
3500 |
|
- |
| 11(Heating, IS 302-1) |
- |
3500 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
3500 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
3500 |
|
- |
| 14(Transient Over Voltages, IS 302-1) |
- |
3500 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
3500 |
|
- |
| 15.2(Moisture Resistance, IS 302-1) |
- |
3500 |
|
- |
| 15(Moisture Resistance, IS 302-1) |
- |
3500 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
3500 |
|
- |
| 19.7(Abnormal Operation, IS 302-1) |
- |
3500 |
|
- |
| 19.8(Abnormal Operation, IS 302-1) |
- |
3500 |
|
- |
| 19.9(Abnormal Operation, IS 302-1) |
- |
3500 |
|
- |
| 19.1(Abnormal Operation, IS 302-1) |
- |
3500 |
|
- |
| 19.101(Abnormal Operation) |
- |
3500 |
|
- |
| 19.102(Abnormal Operation) |
- |
3500 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
3500 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
3500 |
|
- |
| 20.101(Stability & Mechanical Hazards) |
- |
3500 |
|
- |
| 20.102(Stability & Mechanical Hazards) |
- |
3500 |
|
- |
| 20.103(Stability & Mechanical Hazards) |
- |
3500 |
|
- |
| 20.104(Stability & Mechanical Hazards) |
- |
3500 |
|
- |
| 20.105(Stability & Mechanical Hazards) |
- |
3500 |
|
- |
| 20.106(Stability & Mechanical Hazards) |
- |
3500 |
|
- |
| 20.107(Stability & Mechanical Hazards) |
- |
3500 |
|
- |
| 20.108(Stability & Mechanical Hazards) |
- |
3500 |
|
- |
| 20.109(Stability & Mechanical Hazards) |
- |
3500 |
|
- |
| 20.110(Stability & Mechanical Hazards) |
- |
3500 |
|
- |
| 20.111(Stability & Mechanical Hazards) |
- |
3500 |
|
- |
| 20.112(Stability & Mechanical Hazards) |
- |
3500 |
|
- |
| 20.113(Stability & Mechanical Hazards) |
- |
3500 |
|
- |
| 20.114(Stability & Mechanical Hazards) |
- |
3500 |
|
- |
| 20.115(Stability & Mechanical Hazards) |
- |
3500 |
|
- |
| 20.116(Stability & Mechanical Hazards) |
- |
3500 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
3500 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
3500 |
|
- |
| 22(Construction, IS 302-1) |
- |
3500 |
|
- |
| 22.101(Construction) |
- |
3500 |
|
- |
| 22.102(Construction) |
- |
3500 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
3500 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
3500 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
3500 |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
3500 |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
3500 |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
3500 |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
3500 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
3500 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
3500 |
|
- |
| 23.10(Internal Wiring, IS 302-1) |
- |
3500 |
|
- |
| 24.1(Components, IS 302-1) |
- |
3500 |
|
- |
| 24.2(Components, IS 302-1) |
- |
3500 |
|
- |
| 24.5(Components, IS 302-1) |
- |
3500 |
|
- |
| 24.6(Components, IS 302-1) |
- |
3500 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3500 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
3500 |
|
- |
| 27(Provision for Earthing, IS 302-1) |
- |
3500 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
3500 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
3500 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
3500 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
3500 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
3500 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
3500 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
3500 |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
3500 |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
3500 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
3500 |
|
- |
| 32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
3500 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
3500 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
2500 |
|
- |
|
13 Nov, 2026 |
- Exclusion: Cl. 19.11.4.1 (Electrostatic discharges), Cl. 19.11.4.2 (Radiated fields), Cl. 19.11.4.3 (Fast transient bursts), Cl. 19.11.4.4 (Surge immunity test), Cl. 19.11.4.5 (Immunity to conducted discharges), Cl. 19.11.4.6 (Class 3 Voltage dips and interruptions), Cl. 19.11.4.7 (Harmonics) |
| 11850 |
CIPET, Hyderabad
| 6111634
| IS 16008 : Part 2 (2016) |
Agro textiles “ Shade nets for agriculture and horticulture purposes “ Specification Part 2 Shade nets made from mono filament yarns (first revision) |
Shade nets made from mono filament yarns |
17885 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.0(Material) |
- |
1050 |
|
- |
| 4.2(Fabric) |
- |
500 |
|
- |
| 4.3(Colour) |
- |
300 |
|
- |
| 5.0(Types) |
- |
1000 |
|
- |
| 6.1(Dimensions and mass) |
- |
500 |
|
- |
| 6.2 Table 1(Mass g/m2,Min) |
- |
250 |
|
- |
| 6.2 Table 1(Average breaking strength of shade nets fabric (Strip method,Warpway,Weftway
325 mm × 50 mm test piece with gauge length of 200 mm), N, Min
) |
- |
1100 |
|
- |
| 6.2 Table 1(Warpway Weftway) |
- |
500 |
|
- |
| 6.2 Table 1(Retention of breaking strength after UV exposure, N, Min) |
- |
1100 |
|
- |
| 6.2 Table 1(Bursting pressure, kgf/cm2, Min) |
- |
1000 |
|
- |
|
23 Feb, 2027 |
- Including w.e.f. 28.10.2024 |