| 12331 |
BIS, Central Laboratory (CL)
| None
| IS 8654 (2019) |
Automotive hydraulic brake fluid, heavy duty - Specification (Third Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.3 Table 1 (pH value) |
- |
|
|
|
|
- |
- - |
| 12332 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 916 (2000) |
Square tins for solid products - Specification (Fourth Revision) |
- |
4950 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.3.1.1 (Tin Coating Thickness) |
- |
|
|
|
| 4.2 (Dimension and Tolerances) |
- |
|
|
|
| 4.3.2 (Handle wire diameter) |
- |
|
|
|
| 4.4.1 (Body) |
- |
|
|
|
| 4.4.2 (Sides) |
- |
|
|
|
| 4.4.3 (Top and Bottom) |
- |
|
|
|
| 4.1 (Capacity) |
- |
|
|
|
| 5.1 (Air-Pressure Test) |
- |
|
|
|
| 5.2 (Handle Pull Test) |
- |
|
|
|
| 4.2 (Dimension and Tolerances) |
- |
|
|
|
|
- |
- Chemical: Excluding Cu, Tin, Antimony
Mechanical: Test facility is complete |
| 12333 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 513 : Part 2 (2016) |
Cold reduced carbon steel sheet and strip: Part 2 high tensile and multi - Phase steel (Sixth Revision) |
- |
Please see remarks View breakup
Rs.6900/- Excluding Tensile Strain Hardening component, Bake bardending index & surface finish test and Rs.1004/- for each of the elements other than carbon, sulphur, phosphorus and manganese.
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 7 (UTM) |
- |
|
|
|
| Cl 10 (Length, Width & Thickness) |
- |
|
|
|
| Cl 9 (Workmanship) |
- |
|
|
|
|
- |
- " 1m
Excluding Tensile Strain Hardening Component (n-value), surface finish & Chemical facility not available |
| 12334 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 513 : Part 1 (2016) |
Cold reduced carbon steel sheet and strip: Part 1 cold forming and drawing purpose (Sixth Revision) |
- |
Rs.8850/- Excluding Tensile Strain Hardening component View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8 (Mechanical and Physical Properties) |
- |
|
|
|
| Cl 8 (UTM) |
- |
|
|
|
| Cl 10 (Workmanship) |
- |
|
|
|
| Cl 11 (Length, Width & Thickness) |
- |
|
|
|
| 7.0 (ALUMINIUM) |
- |
|
|
|
| 7.0 (MICRO ALLOYS) |
- |
|
|
|
| 7.0 (NITROGEN) |
- |
|
|
|
| 7.0 (SILICON) |
- |
|
|
|
| 7.0 (MANGANESE) |
- |
|
|
|
| 7.0 (PHOSPHORUS) |
- |
|
|
|
| 7.0 (SULPHUR) |
- |
|
|
|
| 7.0 (CARBON) |
- |
|
|
|
|
- |
- " 1m Chemical Facility is available Quantity: 5 Pieces of 5cm X 5cm
Excluding 1.Cupping test, 2.Bend Test, 3. surface finish, 4. Tensile Strain Hardening Component (n-value) 5.Bake Hardening Index – (BH), 6. plastic strain ratio not available |
| 12335 |
BIS, Central Laboratory (CL)
| None
| IS 5852 : Part 1 (2019) |
Toe caps for protection of feet - Specification: Part 1 metallic toe caps (Fifth Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4/4.2/4.2.2-see Fig B-1 (REQUIREMENTS- Dimensions-Width of Flange- as par Annex B.) |
- |
|
|
|
| 4/4.1 (REQUIREMENTS- Finishing) |
- |
|
|
|
| 4/4.2/4.2.1-Table1 (REQUIREMENTS- Dimensions-Internal Length- as par Annex A) |
- |
|
|
|
| 4/4.1 (REQUIREMENTS- Finishing) |
- |
|
|
|
| 4/4.2/4.2.1-Table1 (REQUIREMENTS- Dimensions-Internal Length- as par Annex A) |
- |
|
|
|
| 4/4.2/4.2.2-see Fig B-1 (REQUIREMENTS- Dimensions-Width of Flange- as par Annex B.) |
- |
|
|
|
| 4/4.1 (REQUIREMENTS- Finishing) |
- |
|
|
|
|
- |
- - |
| 12336 |
BIS, Central Laboratory (CL)
| None
| IS 16714 (2018) |
Ground granulated blast furnace slag for use in cement, mortar and concrete - Specification |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 5.1 (Magnesium oxide (MgO)) |
- |
|
|
|
| Clause 5.1 ((CaO+MgO+1/3AlO3)/( SiO2 +2/3 AlO3)) |
- |
|
|
|
| Clause 5.1 ((CaO+CaS+1/2 MgO+Al2O3)/ (SiO2+ MnO)) |
- |
|
|
|
| Clause 5.1 (Sulphide sulphur (S)) |
- |
|
|
|
| Clause 5.1 (Manganese oxide (MnO)) |
- |
|
|
|
| Clause 5.1 ((CaO+MgO+1/3AlO3)/( SiO2 +2/3 AlO3)) |
- |
|
|
|
| Clause 5.1 (Sulphate (as SO3),) |
- |
|
|
|
| Clause 5.1 (Insoluble residue) |
- |
|
|
|
| Clause 5.1 (Loss on ignition) |
- |
|
|
|
| Clause 5.1 (Chloride content) |
- |
|
|
|
| 6 and Table 2 i (Fineness
IS 4031 (Part 2)) |
- |
|
|
|
|
- |
- EXCLUDING Slag F732activity index |
| 12337 |
BIS, Central Laboratory (CL)
| None
| IS 14399 : Part 1 and 2 (1996) |
Hot Press Moulded Thermosetting Glass Fibre Reinforced Polyester Resin (GRP) Sectional Water Storage Tanks : Part 1 palels, Part 2 Guidelines for assembly, installation and test |
- |
Rs. 1350/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.4 (Type/Thickness of panel) |
- |
|
|
|
| 5.0 (DimensionSof Tank) |
- |
|
|
|
|
- |
- - |
| 12338 |
BIS, Central Laboratory (CL)
| None
| IS 15391 (2003) |
Cold rolled non - Oriented electrical steel sheet and strip-semi-processed type - Specification |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8.1 (Thickness) |
- |
|
|
|
| Cl 8.2 (Width) |
- |
|
|
|
| Cl 8.3 (Length) |
- |
|
|
|
| Cl 8.4 (Edge Camber) |
- |
|
|
|
| Cl 8.5 (Flatness) |
- |
|
|
|
| Cl 12 (Surface Condition) |
- |
|
|
|
|
- |
- Since the composition of steel has been left to the discretion ofthe manufacturer , as such element to be tested with specified requirement and tolerances if any may please be declared with method of testing. Sample Size 5 pcs of 5x5 cm having dia> 3mm and thickness > 0.8 mm.;
EXCLUDING -; magnetic characteristics |
| 12339 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 916 (2000) |
Square tins for solid products - Specification (Fourth Revision) |
- |
4950 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2 (Dimension and Tolerances) |
- |
|
|
|
| 4.3.1 (Nominal Thickness) |
- |
|
|
|
| 4.3.2 (Handle wire diameter) |
- |
|
|
|
| 4.4.1 (Body) |
- |
|
|
|
| 4.4.2 (Sides) |
- |
|
|
|
| 4.4.3 (Top and Bottom) |
- |
|
|
|
| 4.4.4 (Top and Bottom embossing) |
- |
|
|
|
| 4.4.5 (Handle) |
- |
|
|
|
| 4.4.6 (Closure) |
- |
|
|
|
| 4.4.7 (Supply condition) |
- |
|
|
|
| 4.4.8 (Internal Finish) |
- |
|
|
|
| 4.4.9 (External Treatment) |
- |
|
|
|
| 5.1 (Air-Pressure Test) |
- |
|
|
|
| 5.2 (Handle Pull Test) |
- |
|
|
|
| 4.1 (Capacity) |
- |
|
|
|
|
- |
- " 2 nos.
Excluding except raw material tests |
| 12340 |
BIS, Central Laboratory (CL)
| None
| IS 7080 : Part 3 (1992) |
MTP suction apparatusspecification: Part 3 electrically operated |
- |
Testing charges not Prepared View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.8.1 (Safety Requirements- Cl.8.1) |
- |
|
|
|
|
- |
- - |
| 12341 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 915 (2012) |
Laboratory glassware - One - Mark volumetric flasks (Third Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table 1 (Nominal Capacity) |
- |
|
|
|
| Table 1 (Internal Neck Diameter) |
- |
|
|
|
| Table 1 (Distance of graduation line) |
- |
|
|
|
| Table 1 (Overall Height) |
- |
|
|
|
| Table 1 (Bulb Diameter) |
- |
|
|
|
| Table 1 (Base Diameter) |
- |
|
|
|
| Table 1 (Wall Thickness) |
- |
|
|
|
| 8.3 (Shape) |
- |
|
|
|
| 8.4 (Neck) |
- |
|
|
|
| 8.5 (Stopper) |
- |
|
|
|
| 9.0 (Graduation Line) |
- |
|
|
|
|
- |
- Excluding Accuracy test and material tests |
| 12342 |
BIS, Central Laboratory (CL)
| None
| IS 5456 (2006) |
Testing of positive displacement type air compressors and exhausters - Code of practice (Second Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 7.2 (Mechanical tests) |
- |
|
|
|
| Cl. 7.2 (Mechanical tests) |
- |
|
|
|
| Cl. 7.2 (Mechanical tests) |
- |
|
|
|
| Cl. 7.2 (Mechanical tests) |
- |
|
|
|
| Cl. 7.2 (Free Air Delivery) |
- |
|
|
|
| Cl. 7.2 (Total Weight of Compressor) |
- |
|
|
|
| Cl. 7.2 (Lubricating Oil Consumption) |
- |
|
|
|
| Cl. 7.2 (Specific Power Consumption/Specific Fuel Consumption at:) |
- |
|
|
|
| Cl. 7.2 (Portability Test Running Trials and Brake Trials) |
- |
|
|
|
| Cl. 7.2 (Overall Dimensions of the Compressor) |
- |
|
|
|
|
- |
- - |
| 12343 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 10577 (1982) |
Specification for lancing pipes |
- |
Rs.3650/- excluding test on joints View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 .1 Table 1,2,3 (Dimensions) |
- |
|
|
|
| 6 .1 Table 1,2,3 ( 1) Outside diameter ) |
- |
|
|
|
| 6 .1 Table 1,2,3 (2) Thickness,mm) |
- |
|
|
|
| 7 Table 1,2,3 ( 2)Mass,kg/m) |
- |
|
|
|
| 6 .1 Table 4 (3)Socket dimension) |
- |
|
|
|
| 6 .1 Table 4 ( i)OD,mm) |
- |
|
|
|
| 6 .1 Table 4 ( ii)Length.mm) |
- |
|
|
|
| 14.1 (Workmanship) |
- |
|
|
|
| 18.0 (Coating ) |
- |
|
|
|
| 13.4.1 ( 1)Drift Expanding Test) |
- |
|
|
|
| 13.2 (i)Tensile strength,, Mpa Min) |
- |
|
|
|
| 13.2 (ii)Elongation,% Min) |
- |
|
|
|
|
- |
- " 2 mtl.
Excluding excl joints, bend test, Hydraulic test & Taper Screw Plug Test and tensile test |
| 12344 |
BIS, Central Laboratory (CL)
| None
| IS 11037 (2019) |
Electronic Type Fan Regulators — Specification ( First Revision ) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.1 (a) (Marking ) |
- |
|
|
|
| 9.1 (b) (Marking ) |
- |
|
|
|
| 9.1 (c) (Marking ) |
- |
|
|
|
| 9.1 (d) (Marking ) |
- |
|
|
|
| 9.1 (e) (Marking ) |
- |
|
|
|
| 9.1 (f) (Marking ) |
- |
|
|
|
| 9.2 (Marking ) |
- |
|
|
|
| 6.1 (Design and General Construction) |
- |
|
|
|
| 6.2 (Design and General Construction) |
- |
|
|
|
| 6.3 (Design and General Construction) |
- |
|
|
|
| 6.5 (Design and General Construction) |
- |
|
|
|
| 6.6 (Design and General Construction) |
- |
|
|
|
| 9.5.5 (Earthing Connection) |
- |
|
|
|
| 9.5.6 (Protection against electric shock (as per Cl.8 of IS 302 (Part 1)) |
- |
|
|
|
| 7.7 (Voltage drop) |
- |
|
|
|
| 8.1 (Performance) |
- |
|
|
|
| 8.2 (Performance) |
- |
|
|
|
| 8.3 (Performance) |
- |
|
|
|
| 9.5.7, 9.5.4 (Moisture Resistance ) |
- |
|
|
|
| 7.4.1(a) (Mechanical strength ) |
- |
|
|
|
| 7.4.1(b) (Mechanical strength ) |
- |
|
|
|
| 9.5.8, (Mechanical strength (as per Cl.21.1 of IS 302-1:2008)) |
- |
|
|
|
| 9.5.9, 7.5, Table-1 (Creepage Distances and Clearances (as per Cl. 29 of IS 302-1)) |
- |
|
|
|
| 9.5.9, 7.5, Table-1 (Creepage Distances and Clearances (as per Cl. 29 of IS 302-1)) |
- |
|
|
|
| 9.5.11.2 (Environmental Tests) |
- |
|
|
|
| 9.5.11.3 (Environmental Tests) |
- |
|
|
|
| 9.5.12 (Resistance to Abnormal Heat and to Fire) |
- |
|
|
|
| 9.5.12.1 (Resistance to Abnormal Heat and to Fire) |
- |
|
|
|
| 9.5.13 (Resistance to Rusting ) |
- |
|
|
|
| 9.5.14 (Checking of Dimensions) |
- |
|
|
|
|
- |
- EXCLUDING Endurace Test / Temperature Rise Test/ Vibration Test; |
| 12345 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 3196 : Part 1 (2013) |
Welded low carbon steel cylinders exceeding 5 litres water capacity for low pressure liquefiable gases: Part 1 cylinders for liquefied petroleum gases (Lpg) - Specification (Sixth Revision) |
- |
14900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10 (Foot Ring) |
- |
|
|
|
| 14 (Bung) |
- |
|
|
|
| 9 (Valve Protection) |
- |
|
|
|
| 14 (Water Capacity) |
- |
|
|
|
| 15 (Hydrostatic Test) |
- |
|
|
|
| 16 (Pneumatic Leakage Test) |
- |
|
|
|
| 17 (Fatigue Test) |
- |
|
|
|
| 17 (Burst Test under Hydraulic Pressure) |
- |
|
|
|
| 18 (Parent Metal Longitudinal Tensile Strength) |
- |
|
|
|
| 18 (Parent Metal Circumferential Tensile Strength) |
- |
|
|
|
| 18 (Parent Metal Longitudinal Tensile Strength) |
- |
|
|
|
| 18 (Parent Metal Circumferential Tensile Strength) |
- |
|
|
|
| 18 (Weld Metal Tensile Strength) |
- |
|
|
|
| 18 (Bend Test across weld) |
- |
|
|
|
| 18 (Root Bend Test) |
- |
|
|
|
| 18 (Face Bend Test) |
- |
|
|
|
| 18 (Minimum Thickness Test) |
- |
|
|
|
| 23.2 (Protective Coatings) |
- |
|
|
|
| 18 (Macro Examination) |
- |
|
|
|
| 20.0 (Marking) |
- |
|
|
|
|
- |
- All test excluding Pneumatic Leakage Test, Static loading and Drop test for capacity above 45 ltr, Cl 19 additional test for steel as per IS 15914, radiography examination |
| 12346 |
BIS, Central Laboratory (CL)
| None
| IS 6593 (1972) |
Specification for electric serological water - Baths |
- |
Rs.10800.0 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1 (as per Cl. 4.2 of IS 302) |
- |
|
|
|
| 5.2 (as per Cl. 5.2) |
- |
|
|
|
| 5.3 (Outer Enclosure) |
- |
|
|
|
| 5.4 (Thermometer) |
- |
|
|
|
| 6.1 (Thickness) |
- |
|
|
|
| 6.2 (as per Cl. 6.2) |
- |
|
|
|
| 6.3 (as per Cl. 6.3) |
- |
|
|
|
| 6.4 (as per Cl. 6.4) |
- |
|
|
|
| 6.5 (Drain Cock or Plug) |
- |
|
|
|
| 6.6 (Thermal Insulation) |
- |
|
|
|
| 6.7 (Outer Enclosure) |
- |
|
|
|
| 6.8 (as per Cl. 6.8) |
- |
|
|
|
| 6.9 (as per Cl. 6.9) |
- |
|
|
|
| 6.1 (Wiring & Components) |
- |
|
|
|
| 6.11 (as per Cl. 6.11) |
- |
|
|
|
| 7.1 (Protection Against Electric Shock- as per IS 302) |
- |
|
|
|
| 7.2 (Input- as per IS 302) |
- |
|
|
|
| 7.3 (Electrical Insulation- as per IS 302) |
- |
|
|
|
| 7.4 (Stability- as per IS 302) |
- |
|
|
|
| 7.5 (Mechanical Strength- as per IS 302) |
- |
|
|
|
| 7.6 (Supply Connection- as per IS 302) |
- |
|
|
|
| 7.7 (Terminals- as per IS 302) |
- |
|
|
|
| 7.8 (Earthing-as per IS 302) |
- |
|
|
|
| 7.9 (Screws & Connections-as per IS 302) |
- |
|
|
|
| 7.1 (Resistance to Rusting- as per IS 302) |
- |
|
|
|
| 8.1 (Heating up time- As per Cl 10.8) |
- |
|
|
|
| 8.2 (Temperature Variation- As per Cl 10.7.2) |
- |
|
|
|
| 8.3 (Temperature Differential- As per Cl 10.7.2) |
- |
|
|
|
| 8.4 (Temperature Drift- As per Cl 10.7.2) |
- |
|
|
|
| 10.6 (Visual Examination & Inspection ) |
- |
|
|
|
| 10.9 (Overflow Test- as per Cl. 10.9) |
- |
|
|
|
|
- |
- - |
| 12347 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 8794 (1988) |
Specification for cast iron detachable joints for use with asbestos cement pressure pipes (First Revision) |
For all DN and Class. |
3900/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1, Table 2 (External Dia of AC Pipe(D2)) |
- |
|
|
|
| 6.1, Table 2 (Inside diaFlange(DI)) |
- |
|
|
|
| 6.1, Table 2 (External Dia at Centre(DEC)) |
- |
|
|
|
| 6.1, Table 2 (Collar Width(Wc)) |
- |
|
|
|
| 6.1, Table 3 (Nominal Dia of Bolt(do)) |
- |
|
|
|
| 6.1, Table 3 (Minimum prefared length of bolt(L)) |
- |
|
|
|
| 8.4 (Coating) |
- |
|
|
|
|
- |
- Excluding Cl 5 Hydrostatic test. Prepared piece required for tensile and hardness test. |
| 12348 |
BIS, Central Laboratory (CL)
| None
| IS 17048 (2018) |
Halogen free flame retardant (HFFR) cables for working voltages up to and including 1 100 Volts - Specification |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1 a) (Conductor : Material ) |
- |
|
|
|
| 4.1.1 b) (Material : Seperator tape ) |
- |
|
|
|
| 4.1.1 d) , 11.1, 12.1, 13.1,14.1 (Class of conductor ) |
- |
|
|
|
| 4.1.1 e) (Shape of conductor ) |
- |
|
|
|
| 4.1.1 f) (Nominal size of conductor ) |
- |
|
|
|
| 4.2.1, 11.2, 12.2, 13.2, 14.2 (Insulation : Material ) |
- |
|
|
|
| 4.2.2, 11.2, 12.2, 13.2, 14.2 (Insulation : Application ) |
- |
|
|
|
| 4.2.3,11.2, 12.2, 13.2 (Thickness of insulation - Avearge : IS 10810 ( Part 6 )) |
- |
|
|
|
| 4.2.3, 11.2, 12.2, 13.2, 14.2 (Thickness of insulation - miniumum : IS 10810 ( Part 6 )) |
- |
|
|
|
| 4.3 (Fillers) |
- |
|
|
|
| 4.4 (Binder Tape) |
- |
|
|
|
| 4.5.1,13.4, 14.4 (Sheath : Compound ) |
- |
|
|
|
| 4.5.2, 13.4, 14.4 (Sheath : Application) |
- |
|
|
|
| 4.5.3,13.4, 14.4 (Thickness of sheath - Average : IS 10810 (Part 6)) |
- |
|
|
|
| 4.5.3,13.4, 14.4 (Thickness of sheath - Minimum : IS 10810 (Part 6)) |
- |
|
|
|
| 4.5.5, 11.3, 12.3, 13.6, 14.6 (Overall Dimensions) |
- |
|
|
|
| 4.5.5.1, 11.3, 12.3,13.5, 14.5 (Ovality) |
- |
|
|
|
| 4.5.6, 13.4 (Colour of Sheath) |
- |
|
|
|
| 5.1 (High Voltage Test (at Room Temperature)) |
- |
|
|
|
| 5.3 (Flammability Test- IS 10810 (Part 53).) |
- |
|
|
|
| 5.1 (Persulphate Test- IS 10810 (Part 4).) |
- |
|
|
|
| 5.12 (Hot Set Test- IS 10810 (Part 30).) |
- |
|
|
|
| 5.12 (Permanent Set - IS 10810 (Part 30).) |
- |
|
|
|
| 5.13 (Water Immersion Test (Effect of Water on Sheath) : Tensile strength -IS 10810 (Part 7).) |
- |
|
|
|
| 5.13 (Water Immersion Test (Effect of Water on Sheath) : Elogation -IS 10810 (Part 7).) |
- |
|
|
|
| 5.15 (Cold Bend Test-IS 10810 (Part 20).) |
- |
|
|
|
| 5.16 (Cold Impact Test- IS 10810 (Part 21).) |
- |
|
|
|
| 4.2.4 (Insulation : Tensile stregth ( Before ageing)-IS 10810 (Part 7) ) |
- |
|
|
|
| 4.2.4 (Insulation : Elongation ( Before ageing) -IS 10810 (Part 7)) |
- |
|
|
|
| 4.2.4 (Insulation : Tensile stregth ( After ageing) - IS 10810 (Part 7) ) |
- |
|
|
|
| 4.2.4 (Insulation : Elongation (after ageing) - IS 10810 (Part 7) ) |
- |
|
|
|
| 4.2.5 (Insulation : Tensile stregth variation ( After ageing) - IS 10810 (Part 7) ) |
- |
|
|
|
| 4.2.5 (Insulation : Elongation variation (after ageing) - IS 10810 (Part 7) ) |
- |
|
|
|
| 4.5.4, 13.4 (Sheath : Tensile stregth ( Before ageing)-IS 10810 (Part 7) ) |
- |
|
|
|
| 4.5.4,13.4 (Sheath : Elongation ( Before ageing) -IS 10810 (Part 7)) |
- |
|
|
|
| 4.5.4, 13.4, 14.4 (Sheath : Tensile stregth ( After ageing) - IS 10810 (Part 7) ) |
- |
|
|
|
| 4.5.4, 13.4, 14.4 (Sheath : Elongation (after ageing) - IS 10810 (Part 7) ) |
- |
|
|
|
| 4.5.5, 13.4, 14.4 (Sheath : Tensile stregth variation ( After ageing) - IS 10810 (Part 7) ) |
- |
|
|
|
| 4.5.5, 13.4,14.4 (Sheath : Elongation variation (after ageing) - IS 10810 (Part 7) ) |
- |
|
|
|
| 5.16 (Cold Impact Test- IS 10810 (Part 21).) |
- |
|
|
|
| 6.1, Table 1 (CORE IDENTIFICATION) |
- |
|
|
|
| 6.2 (Core Identification by Numbers) |
- |
|
|
|
| 6.2.2 (Durability) |
- |
|
|
|
| 10.2 (marking) |
- |
|
|
|
| 10.2.1 (Standards marking) |
- |
|
|
|
| Cl.4.2.1 & Annex A (Insulation Resistance Constant at Rated Temperature (70°C)) |
- |
|
|
|
| Table 2, III a (i) (Conductor Resistance) |
- |
|
|
|
| Annex A (Hot Deformation) |
- |
|
|
|
|
- |
- EXCLUDING Oxygen index, Temperature index, Ozone resistance test, Assessment of halogen, Flame retardant test & Smoke density test; |
| 12349 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 16720 (2018) |
Pulverized Fuel Ash-Cement Bricks- Specification |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 and fig.1A &1B (Dimensions- Length (L) ) |
- |
|
|
|
| 4.1 and fig.1A &1B (Dimensions- Width (B) ) |
- |
|
|
|
| 4.1 and fig.1A &1B (Dimensions- Height (H)) |
- |
|
|
|
| 4.1 & 4.3 and fig.1A &1B (Dimensions - Depth) |
- |
|
|
|
| 4.1 and fig.1A &1B (Dimensions) |
- |
|
|
|
| 8.1 (GENERAL) |
- |
|
|
|
| 8.3 (Density
Annex C of IS 2185 (Part 1)) |
- |
|
|
|
| 8.4 and Table 1 (Compressive Strength - Individual
IS 3495 (Part 1)) |
- |
|
|
|
| 8.4 and Table 1 (Compressive Strength - Average
IS 3495 (Part 1)) |
- |
|
|
|
| 8.6 (Water Absorption
IS 3495 (Part 2)) |
- |
|
|
|
| 8.5 (Drying Shrinkage
IS 4139) |
- |
|
|
|
|
- |
- Complete |
| 12350 |
BIS, Central Laboratory (CL)
| None
| IS 3470 (2017) |
Hexane, food grade - Specification (Second Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table 1(i) (Density at — [P : 32]1) / [P : 16]/ ASTM D IS 4502/ ISO 3675 / ISO 12185) |
- |
|
|
|
| Table 1(iv) (Non-volatile residue, Annex A) |
- |
|
|
|
| Table 1(v) (Reaction of non-volatile residue, Annex B) |
- |
|
|
|
| Table 1(vii) (Lead, as Pb, Annex D4, ASTM D 3605) |
- |
|
|
|
|
- |
- - |
| 12351 |
BIS, Central Laboratory (CL)
| None
| IS 4533 (1995) |
Suction apparatus - Specification (Second Revision) |
- |
Please see remarks. View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Metal Parts- as per Cl. 4.1) |
- |
|
|
|
| 4.2 (Rubber Components- as per Cl. 4.2) |
- |
|
|
|
| 4.3 (Glass-as per Cl. 4.3) |
- |
|
|
|
| 4.4 (Glass-as per Cl. 4.4) |
- |
|
|
|
| 5.2 (Base- as per Cl. 5.2) |
- |
|
|
|
| 5.3 (Vaccum Gauge- as per Cl. 5.3) |
- |
|
|
|
| 5.3.1 (as per Cl. 5.3.1) |
- |
|
|
|
| 5.4 (Suction Bottle & Lid) |
- |
|
|
|
| 5.5 (Suction System Filters &Traps) |
- |
|
|
|
| 5.6 (Tubings & Couplings) |
- |
|
|
|
| 5.7 (Castors) |
- |
|
|
|
| 6.3 (as per Cl. 6.3) |
- |
|
|
|
| 6.5 (as per Cl. 6.5) |
- |
|
|
|
| 6.6 (as per Cl. 6.6) |
- |
|
|
|
| 8.1 (as per Cl. 8.1) |
- |
|
|
|
| 8.3 (Cl. 8.3- As per IS 1068) |
- |
|
|
|
| 9.1 (Adhesion Test- as per Cl. 9.1) |
- |
|
|
|
|
- |
- - |
| 12352 |
BIS, Central Laboratory (CL)
| None
| IS 3899 (1981) |
Specification for zineb, water dispersible powders |
- |
Please see remarks. View breakup
a) When the sample has crossed half shelf life : Rs. 825.00
b) When the sample has not crossed half shelf life : Rs. 1275.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.2 Table 1 (Wettability) |
- |
|
|
|
| 2.2 Table 1 ( Zineb content, NV upto 9) |
- |
|
|
|
| 2.2 Table 1 (Zineb content, NV above 9 and below 50) |
- |
|
|
|
| 2.2 Table 1 (Zineb content, NV above 50) |
- |
|
|
|
| 2.2 Table 1 (Suspensibility, after accelerated storage) |
- |
|
|
|
| 2.2 Table 1 (Material passing through 45 micron IS Sieve, after
accelerated storage) |
- |
|
|
|
| 2.1 (Description) |
- |
|
|
|
|
- |
- - |
| 12353 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 3601 (2006) |
Steel tubes for mechanical and general engineering purposes - Specification (Second Revision) |
- |
Please see remarks. View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0 (Workmanship) |
- |
|
|
|
| 8.0 (Straightness) |
- |
|
|
|
| 11.1 (Surface Protection) |
- |
|
|
|
| 11.2 (Surface Protection) |
- |
|
|
|
| 19.1.1, 24.1.1, 28.1.1, 33.1.1 (Dimensions- Outside Dia) |
- |
|
|
|
| 19.1.2, 24.1.2, 28.1.2, 33.1.2 (Dimensions- Thickness) |
- |
|
|
|
| 13.1.3 (Tensile Strength) |
- |
|
|
|
| 13.1.1 (Yield Stress) |
- |
|
|
|
| 13.1.2 (Elongation) |
- |
|
|
|
| 13.2 (Flattening Test) |
- |
|
|
|
| 13.3 (Bend Test (Strip)) |
- |
|
|
|
| 13.6 (Crush Test) |
- |
|
|
|
| 19.1.3 (Height of Internal Fin) |
- |
|
|
|
| 11.1 (Surface Protection) |
- |
|
|
|
| 11.2 (Surface Protection) |
- |
|
|
|
| 4.1 (Sulphur-Percentage by mass) |
- |
|
|
|
| 4.1 (Phosphorus-Percentage by mass) |
- |
|
|
|
| 13.4 (Bend Test (Whole Tube)) |
- |
|
|
|
| 16 (Marking) |
- |
|
|
|
| Cl. 10 Annex B Cl. 17, Cl. 19 (Mass) |
- |
|
|
|
| 4.0 (c) (Micro Alloying elements (Nb+V+Ti)) |
- |
|
|
|
| 4.0 (f) (Nitrogen content) |
- |
|
|
|
| 4.0 (a) (Carbon as C - IS:8811) |
- |
|
|
|
| 4.0 (b) (Manganese as Mn - IS:8811) |
- |
|
|
|
|
- |
- Test facility is complete |
| 12354 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 5135 : Part 1 (1994) |
Specification for hand - Rotary duster: Part 1 belly - Mounted type (Second Revision) |
- |
Testing charges for the product are Rs 7600/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0 (Capacity) |
- |
|
|
|
| 8.0 (WORKMANSHIP AND FINISH) |
- |
|
|
|
|
- |
- " 1 set
Excluding 1.Test for Agitation 2.Test for Strap and Its Assembly 3.PERFORMANCE REQUIREMENTS 4. raw material tests |
| 12355 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 1711 (1984) |
Specification for self - Closing taps for water supply purposes |
- |
Rs 600/-,excl endurance test View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 3 (NOMINAL SIZE) |
- |
|
|
|
| Cl. 5 (MANUFACTURE AND WORKMANSHIP) |
- |
|
|
|
| Cl. 6.2 (Body and Gland) |
- |
|
|
|
| Cl. 6.3 (Valve and Spindle) |
- |
|
|
|
| Cl. 6.4 (Screw Threads ) |
- |
|
|
|
| Cl. 6.5 (Washers) |
- |
|
|
|
| Cl. 7 (FINISH) |
- |
|
|
|
|
- |
- " 5 NOS.+PIECE FOR COATING
Excluding Except test for flow of water at the outlet end (cl 8.2) and endurance test |
| 12356 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 15914 (2011) |
High tensile strength flat rolled steel plate (Up To 6 Mm), sheet and strip for the manufacture of welded gas cylinder - Specification |
- |
Rs. 7760/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 7 (UTM) |
- |
|
|
|
| Cl 9 (Workmanship) |
- |
|
|
|
| Cl 10 (Length, Width & Thickness) |
- |
|
|
|
| 6.0 (CARBON) |
- |
|
|
|
| 6.0 (SULPHUR) |
- |
|
|
|
| 6.0 (SILICON) |
- |
|
|
|
| 6.0 (MANGANESE) |
- |
|
|
|
| 6.0 (PHOSPHORUS) |
- |
|
|
|
| 6.0 (NITROGEN) |
- |
|
|
|
|
- |
- Excluding Microalloying Elements |
| 12357 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 878 (2008) |
Laboratory glassware - Graduated measuring cylinders (Second Revision) |
- |
Rs.4200/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table-1 (Nominal capacity) |
- |
|
|
|
| Table-1 (Overall height) |
- |
|
|
|
| Table-1 (Distance from top of scale to top of cylinder) |
- |
|
|
|
| Table-1 (Internal height to highest graduation line) |
- |
|
|
|
| Table-1 (Sub-divisions) |
- |
|
|
|
| Table-1 (capacity at lowest graduation line) |
- |
|
|
|
|
- |
- Excluding Accuracy test and material test |
| 12358 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 10908 (1991) |
Flexible rubber tubing for liquefied petroleum gas - Specification (First Revision) |
- |
7800 View breakup
Rs.7800.00 (excluding testing charges for Resistance to Ozone test). * Testing facility not available at CL for Resistance for Ozone test.
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.4.1 (The tubing made out of this material shall be green in colour ) |
- |
|
|
|
| Cl.4.2 (The walls shall be seamless and free from all visible such as lumps, blows-holes,cracks etc and the bore shall be clean and free from loose particles which might be carried forward by the gas) |
- |
|
|
|
| Cl4.3.1 (The tubing shall be supplied in 6.4 and 7.0 mm inisde diametre,The tolerance on nominal diamtere shall be as per table 1) |
- |
|
|
|
| Cl4.3.2 (it shall comply with the thickness as givien in table 1 when measured according to 4.2.2 of IS 443;1975 The readings shall be taken from different sample sections.) |
- |
|
|
|
| Cl.4.4,(Cl.4.4.1) (when tested in accordance with the method given in AnnexureA. It shall fit over the standard and oversize metal nozzle shown in Fig1,2 and 3) |
- |
|
|
|
| Cl.4.4,(Cl.4.4.2) (it shall remain atatched to both nozzles throught the test period) |
- |
|
|
|
| Cl.4.5 (When immersed in water for 5 minutes under an internal air pressure of 0.25 Mpa or 250kPa (2.5 bar), the increase in the outside diametre of the tubing ,Also the same shall not burst when the pressure is increasded to 0.5 Mpa or 500 kpa (5 bar0, The test shall be carried out on a lengtj of 60 cm.) |
- |
|
|
|
| Cl.4.5 (When immersed in water for 5 minutes under an internal air pressure of 0.25 Mpa or 250kPa (2.5 bar), the same shall not burst when the pressure is increasded to 0.5 Mpa or 500 kpa (5 bar0, The test shall be carried out on a lengtj of 60 cm.) |
- |
|
|
|
| Cl.4.9 (Crushing test , ) |
- |
|
|
|
| Cl.4.6 (Shore Hardness: the hardnesss on the flatsurface of the cut/slit tubing shall be measured and the same shall be 60 ± 5˚A) |
- |
|
|
|
| Cl.4.7 (Accelerated Ageing test, the flexible tubing or suitable portion of the tubing shall be subjected to accelerated ageing at a temperature of 100Deg Cfor 72 hours in accordance with the method prescribed in IS 3400 (Part 4) it shall not show a change of + 10 A of its orignal shore hardness ) |
- |
|
|
|
| Cl.4.8.1 (Flexible test , Annexure B The gas pressure shown on the manometre shall not drop by more than 1 Kpa) |
- |
|
|
|
| Cl4.8.2 (The tubing shall be so flexible that it will make contact with a cylinder former of radius 68 mm for at least 110 deg of its circumference when the tubing is placed over the framer and a mass of 1.6 kg is attcahed to each end) |
- |
|
|
|
| Cl.4.10 (Resistance to lpg ,Annexure c Shall not be more than 15 % of the initial mass of the tubing and the amount of exctractable matter shall not excced 10 percent of the iniital mass of te tubing) |
- |
|
|
|
| Cl.4.11 (Resistance to Ozone ,Annexure D Shall not show any breakage on surface or crack or defects) |
- |
|
|
|
| Cl.4.12 (Burning behaviour on exposure to small flame,Annexure E tubing shall not burn to either of the outer marks within the test period of 45 seconds) |
- |
|
|
|
|
- |
- Excluding Resistance to Ozone, Resistance to LPG, Accelerated Ageing test flexibilty test, thickness and hardness |
| 12359 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 1835 (1976) |
Specification for round steel wire for ropes (Third Revision) |
- |
Rs 4500/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 3 (Manufacturing ) |
- |
|
|
|
| Cl 7 (Workmanship) |
- |
|
|
|
| Cl 8 (Manufacturing ) |
- |
|
|
|
| Cl 10 (Diameter) |
- |
|
|
|
| Cl 11.2 (Workmanship) |
- |
|
|
|
| Cl 12.2 (UTM) |
- |
|
|
|
| Cl 12.3 (Torsion) |
- |
|
|
|
| Cl 12.4 (Reverse Bend) |
- |
|
|
|
| Cl 12.5 (Wrap) |
- |
|
|
|
| Cl 12.6 (Adhesion ) |
- |
|
|
|
| Cl 11.3 (Coating Test) |
- |
|
|
|
| Cl. 9.1, T-3 (Mass of Zinc Coating) |
- |
|
|
|
| Cl. 9.1, T-3 (Uniformity) |
- |
|
|
|
| Cl. 5.1, T-1 (C) |
- |
|
|
|
| Cl. 5.1, T-1 (Mn) |
- |
|
|
|
| Cl. 5.1, T-1 (Si) |
- |
|
|
|
| Cl. 5.1, T-1 ( Grade 1) (P) |
- |
|
|
|
| Cl. 5.1, T-1 ( Grade 1) (S) |
- |
|
|
|
| Cl. 5.1, T-1 ( Grade 5) (Cr) |
- |
|
|
|
| Cl. 5.1, T-1 ( Grade 1) (Cu) |
- |
|
|
|
| Cl. 5.1, T-1 ( Grade 2) (Cu) |
- |
|
|
|
| Cl. 5.1, T-1 ( Grade 3) (Cu) |
- |
|
|
|
| Cl. 5.1, T-1 ( Grade 4) (Cu) |
- |
|
|
|
| Cl. 5.1, T-1 ( Grade 5) (Cu) |
- |
|
|
|
| Cl. 5.1, T-1 ( Grade 1) (Ni) |
- |
|
|
|
| Cl. 5.1, T-1 ( Grade 2) (Ni) |
- |
|
|
|
| Cl. 5.1, T-1 ( Grade 3) (Ni) |
- |
|
|
|
| Cl. 5.1, T-1 ( Grade 4) (Ni) |
- |
|
|
|
| Cl. 5.1, T-1 ( Grade 5) (Ni) |
- |
|
|
|
|
- |
- Excluding Microalloying Elements for the wire having diameter below 4mm |
| 12360 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 3954 (1991) |
Hot Rolled Steel Channel Sections for General Engineering Purposes - Dimensions |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4, 6.1, Table 1 (CHG 16, Mass) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 16, Depth of channel) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 16, Width of flange) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 16, Thickness of web) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 16, Thickness of flange) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 16, Radius at root) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 16, Radius at toe) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 16, Centre of gravity) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 16, Slope of flange) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 20, Mass) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 20, Depth of channel) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 20, Width of flange) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 20, Thickness of web) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 16, Thickness of flange) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 20, Slope of flange) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 20, Radius at root) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 16, Radius at toe) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 20, Centre of gravity) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 40, Mass) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 40, Depth of channel) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 40, Width of flange) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 40, Slope of flange) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 40, Radius at root) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 16, Radius at toe) |
- |
|
|
|
| 4, 6.1, Table 1 (CHG 40, Centre of gravity) |
- |
|
|
|
|
- |
- Test facility is complete |