| 12361 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 1264 (1997) |
Brass gravity die castings - Specification (Fourth Revision) |
- |
1435.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.0 (Freedom from defects) |
- |
|
|
|
| 6.0 (Size) |
- |
|
|
|
| 6.0 (Mass) |
- |
|
|
|
| 9.0 (Pressure test) |
- |
|
|
|
|
- |
- Facility for Chemical tests not available |
| 12362 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 6760 (1972) |
Specification for slotted countersunk head wood screws |
- |
Rs.900.0 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1, Table 1 (Diameter of Unthreaded Shank d, Nominal) |
- |
|
|
|
| 3.1, Table 1 (Diameter of Unthreaded Shank d, maximum) |
- |
|
|
|
| 3.1, Table 1 (Diameter of Unthreaded Shank d, Minimum) |
- |
|
|
|
| 3.1, Table 1 (V*) |
- |
|
|
|
| 3.1, Table 1 (Pitch) |
- |
|
|
|
| 3.1, Table 1 (Diameter of Head, D, Maximum) |
- |
|
|
|
| 3.1, Table 1 (Diameter of Head, D, Minimum) |
- |
|
|
|
| 3.1, Table 1 (Depth of Head c†, maximum) |
- |
|
|
|
| 3.1, Table 1 (Depth of Head c†, minimum) |
- |
|
|
|
| 3.1, Table 1 (Width of Slot s, maximum) |
- |
|
|
|
| 3.1, Table 1 (Width of Slot s, minimum) |
- |
|
|
|
| 3.1, Table 1 (Depth Slot n‡, Maximum) |
- |
|
|
|
| 3.1, Table 1 (Depth Slot n‡, Mainimum) |
- |
|
|
|
|
- |
- - |
| 12363 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 274 : Part 1 and 2 (1981) |
Specification for shovels: Part 1 genral purpose shovels: Part 2 heat - Treated shovels (Third Revision) |
- |
Rs 600/, Rs 675/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5 Table-1,2 (Shape) |
- |
|
|
|
| 5 Table-1,2 (Dimensions- A) |
- |
|
|
|
| 5 Table-1,2 (Dimensions- B) |
- |
|
|
|
| 5 Table-1,2 (Dimensions- C) |
- |
|
|
|
| 5 Table-1,2 (Dimensions- D) |
- |
|
|
|
| 5 Table-1,2 (Dimensions- E) |
- |
|
|
|
| 5 Table-1,2 (Dimensions- G) |
- |
|
|
|
| 5 Table-1,2 (Dimensions- H) |
- |
|
|
|
| 5 Table-1,2 (Dimensions- K) |
- |
|
|
|
| 5 Table-1,2 (Dimensions- L) |
- |
|
|
|
| 6.1 (Blade thickness) |
- |
|
|
|
| 7.0 (Mass) |
- |
|
|
|
| 8.0 (Manufacture) |
- |
|
|
|
| 8.0 (Manufacture) |
- |
|
|
|
| 8.0 (Manufacture) |
- |
|
|
|
| 9.1 (Handles) |
- |
|
|
|
| 9.3 (Handles) |
- |
|
|
|
| 11.0 (Workmanship & Finish
) |
- |
|
|
|
| 12.0 (Preservative Treatment
) |
- |
|
|
|
| 4.1 (Sulphur) |
- |
|
|
|
| 4.1 (Phosphorus) |
- |
|
|
|
|
- |
- Excluding Microalloying Elements |
| 12364 |
BIS, Guwahati Branch Laboratory (GBL)
| None
| IS 4990 (2011) |
Plywood for concrete shuttering works - Specification (Third Revision) |
- |
Rs 11950/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.0 (Types) |
- |
|
|
|
| 7.2 (DIMENSIONS &
TOLERANCES
) |
- |
|
|
|
| 7.2 (DIMENSIONS &
TOLERANCES
) |
- |
|
|
|
| 7.3 (DIMENSIONS &
TOLERANCES
) |
- |
|
|
|
| 7.4 (DIMENSIONS &
TOLERANCES
) |
- |
|
|
|
| 7.4 (DIMENSIONS &
TOLERANCES
) |
- |
|
|
|
| 8.1 (WORKMANSHIP AND FINISH ) |
- |
|
|
|
| 8.3 (WORKMANSHIP AND FINISH ) |
- |
|
|
|
| 10.1.1 (MOISTURE CONTENT) |
- |
|
|
|
| 10.1.2, 10.1.2.1 (Table-1) (GLUE ADHESION IN DRY STATE) |
- |
|
|
|
| 10.1.2, 10.1.2.2 (GLUE ADHESION IN DRY STATE) |
- |
|
|
|
| 10.1.3, 10.1.3.1.1 (Table-1) (RESISTANCE TO WATER TEST) |
- |
|
|
|
| 10.1.3, 10.1.3.1.2 (RESISTANCE TO WATER TEST) |
- |
|
|
|
| 10.1.4 (RESISTANCE TO WATER TEST) |
- |
|
|
|
| 10.1.5 (MYCOLOGICAL TEST ) |
- |
|
|
|
| 10.1.5, 10.1.5.1 (Table-1) (MYCOLOGICAL TEST ) |
- |
|
|
|
| 10.1.5.2 (MYCOLOGICAL TEST ) |
- |
|
|
|
| Cl. 10.1.6 (Cl. 10.1.6 (Tensile Strength: Parallel to grain)) |
- |
|
|
|
| 10.1.7 (Table-2) (STATIC BENDING STRENGTH) |
- |
|
|
|
| Cl. 10.1.7 (Table 2) (Cl. 10.1.7 (Table 2) (Modulus of Elasticity: Along the Face Grain: Average)) |
- |
|
|
|
| 10.1.8 (Table-3) (WET BENDING STRENGTH) |
- |
|
|
|
| Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Elasticity: Along the Face Grain: Average)) |
- |
|
|
|
| 12, 12.1 (MARKING) |
- |
|
|
|
| 12, 12.2 (MARKING) |
- |
|
|
|
| Cl. 10.1.6 (Cl. 10.1.6 (Tensile Strength: Perpendicular to grain)) |
- |
|
|
|
| Cl. 10.1.6 (Cl. 10.1.6 (Tensile Strength: Sum of the Tensile Strength in two directions)) |
- |
|
|
|
| Cl. 10.1.7 (Table 2) (Cl. 10.1.7 (Table 2) (Modulus of Elasticity: Along the Face Grain: Minimum Individual)) |
- |
|
|
|
| Cl. 10.1.7 (Table 2) (Cl. 10.1.7 (Table 2) (Modulus of Elasticity: Across the Face Grain: Average)) |
- |
|
|
|
| Cl. 10.1.7 (Table 2) (Cl. 10.1.7 (Table 2) (Modulus of Elasticity: Across the Face Grain: Minimum Individual)) |
- |
|
|
|
| Cl. 10.1.7 (Table 2) (Cl. 10.1.7 (Table 2) (Modulus of Rupture: Along the Face Grain: Average)) |
- |
|
|
|
| Cl. 10.1.7 (Table 2) (Cl. 10.1.7 (Table 2) (Modulus of Rupture: Along the Face Grain: Minimum Individual)) |
- |
|
|
|
| Cl. 10.1.7 (Table 2) (Cl. 10.1.7 (Table 2) (Modulus of Rupture: Across the Face Grain: Average)) |
- |
|
|
|
| Cl. 10.1.7 (Table 2) (Cl. 10.1.7 (Table 2) (Modulus of Rupture: Across the Face Grain: Minimum Individual)) |
- |
|
|
|
| Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Elasticity: Along the Face Grain: Minimum Individual)) |
- |
|
|
|
| Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Elasticity: Across the Face Grain: Average)) |
- |
|
|
|
| Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Elasticity: Across the Face Grain: Minimum Individual)) |
- |
|
|
|
| Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Rupture: Along the Face Grain: Average)) |
- |
|
|
|
| Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Rupture: Along the Face Grain: Minimum Individual)) |
- |
|
|
|
| Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Rupture: Across the Face Grain: Average)) |
- |
|
|
|
| Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Rupture: Across the Face Grain: Minimum Individual)) |
- |
|
|
|
| cl. 10.1.2.1 (glue adhesion in dry state - glue shear strength - AVERAGE) |
- |
|
|
|
| cl. 10.1.2.1 (glue adhesion in dry state - glue shear strength - WOOD FAILURE, Average) |
- |
|
|
|
| cl. 10.1.3.1 (resistance to water test - glue shear strength - AVERAGE) |
- |
|
|
|
| cl. 10.1.3.1 (resistance to water test - glue shear strength - WOOD FAILURE, Average) |
- |
|
|
|
| cl. 10.1.5.1 (mycological test - glue shear strength - AVERAGE) |
- |
|
|
|
| cl. 10.1.5.1 (mycological test - glue shear strength - WOOD FAILURE, Average) |
- |
|
|
|
| 10.1.9(Chem) (RETENTION OF PRESERVATIVE) |
- |
|
|
|
|
- |
- - |
| 12365 |
BIS, Bengaluru Branch Laboratory (BNBL)
| None
| IS 3802 (2019) |
Roasted coffee - Chicory powder - Specification (Second Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Annex E of IS 3077 (Moisture, percent by mass, Max) |
- |
|
|
|
| Annex F of IS 3077 (Total ash, percent by mass (on dry basis)) |
- |
|
|
|
| Annex G of IS 3077 (Acid insoluble ash (on dry basis), percent by mass, Max) |
- |
|
|
|
| Annex K of IS 3077 (Water soluble matter (on dry basis), percent by mass) |
- |
|
|
|
| Annex L of IS 3077 (Caffeine (on dry basis), percent by mass, Min) |
- |
|
|
|
| Clause 15 of IS 1699 (Copper, ppm, Max) |
- |
|
|
|
|
- |
- Exclsuion
i)Caffeine (on dry basis) |
| 12366 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 2039 : Part 1 to 3 (1991) |
Steel tubes for bicycle and cycle rickshaws - Specification (Second Revision) |
- |
Rs.4320.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6.1 (Workmanship) |
- |
|
|
|
| Cl. 6.2 (Fin Height) |
- |
|
|
|
| Cl. 6.3 (Straightness) |
- |
|
|
|
| Cl. 8.1 (Tensile Strength) |
- |
|
|
|
| Cl. 8.1 (Yield Strength) |
- |
|
|
|
| Cl. 8.1 (Elongation) |
- |
|
|
|
| Cl. 8.2 (Drift Expansion Test- IS 2335) |
- |
|
|
|
| Cl. 8.3 (Flattening Test-IS 2338) |
- |
|
|
|
| Cl. 9 (Diameter) |
- |
|
|
|
| Cl. 9 (Thickness) |
- |
|
|
|
| Cl. 3.2.1, Table 4 (Yield Stress) |
- |
|
|
|
| Cl. 3.2.1, Table 4 (UTS) |
- |
|
|
|
| Cl. 3.2.1, Table 4 (Elongation) |
- |
|
|
|
| Cl. 3.2.2, Table 2 (Drift Expansion Test- IS 2335) |
- |
|
|
|
| Cl. 3.2.3, Table 3 (Flattening Test-IS 2338) |
- |
|
|
|
| Cl. 4.2.1 (Diameter) |
- |
|
|
|
| Cl. 4.2.2 (Thickness) |
- |
|
|
|
| Cl. 4.2.3 (Length) |
- |
|
|
|
| Cl. 4.2.1, Table 7 (Yield Stress) |
- |
|
|
|
| Cl. 4.2.1, Table 7 (UTS) |
- |
|
|
|
| Cl. 4.2.1, Table 7 (Crushing) |
- |
|
|
|
| Cl. 4.2.2, Table 8 (Drift Expansion Test- IS 2335) |
- |
|
|
|
| Cl. 4.2.3, Table 9 (Flattening Test-IS 2338) |
- |
|
|
|
| Cl. 5.2.1, Table 10 (Diameter) |
- |
|
|
|
| Cl. 5.2.2 (Mean Thickness) |
- |
|
|
|
| Cl. 5.2.3, Table 6 (Length) |
- |
|
|
|
| Cl. 5.1 Table 1 (Carbon) |
- |
|
|
|
| Cl. 3.1 (Sulphur) |
- |
|
|
|
| Cl. 3.1 (Phosphorous) |
- |
|
|
|
| Cl. 3.1 (Manganese) |
- |
|
|
|
| Cl. 3.1 (Silicon) |
- |
|
|
|
|
- |
- - |
| 12367 |
BIS, Bengaluru Branch Laboratory (BNBL)
| None
| IS 10116 (2015) |
Boric acid - Specification (First Revision) |
- |
Please see remarks View breakup
Testing Charge for Boric Acid- a) Special Quality (SQ) Grade= 13.25x300+10x9+700 =Rs. 4765/-= Rs. 4800/- (Rounded off)
Testing Charge for Boric Acid- b) Technical (TECH) Grade= 5.25x300+9x9+300 =Rs. 1956/-= Rs. 2000/- (Rounded off)
Testing Charge for Boric Acid- c) Explosive Grade= 6.25x300+9x9+350 =Rs. 2306/-= Rs. 2300/- (Rounded off)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2, 4.3, 4.4, Table 1 (Boric acid (as H3BO3 )) |
- |
|
|
|
| 4.2, 4.3, 4.4, Table 1 (Water insoluble matter) |
- |
|
|
|
| 4.2, 4.3, 4.4, Table 1 (Heavy metals (as Pb)) |
- |
|
|
|
| 4.2, 4.3, 4.4, Table 1 (Iron (as Fe)) |
- |
|
|
|
| 4.2, 4.3, 4.4, Table 1 (Ca) |
- |
|
|
|
| 4.2, 4.3, 4.4, Table 1 (Na) |
- |
|
|
|
| 4.2, 4.3, 4.4, Table 1 (Cl) |
- |
|
|
|
| 4.2, 4.3, 4.4, Table 1 (Sulphate (as SO4 )) |
- |
|
|
|
| 4.2, 4.3, 4.4, Table 1 (Phosphate (PO4 )) |
- |
|
|
|
| 4.5 (Additional Requirement for Technical Grade Boric Acid) |
- |
|
|
|
| 4.2, 4.3, 4.4, Table 1 (Moisture) |
- |
|
|
|
| 4.2
( Description) |
- |
|
|
|
|
- |
- Excluding Calcium in special grade |
| 12368 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 5135 : Part 2 (1994) |
Specification for hand rotary duster: Part 2 shoulder mounted type (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0 (Capacity) |
- |
|
|
|
| 8.0 (WORKMANSHIP AND FINISH) |
- |
|
|
|
|
- |
- - |
| 12369 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 4366 : Part 2 (1985) |
Specification for agricultural tillage discs: Part 2 flat type (Second Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.0 (HARDNESS) |
- |
|
|
|
| 5.1, Table 1 (Nominal size) |
- |
|
|
|
| 5.1, Table 1 (Thickness) |
- |
|
|
|
| 5.2, Table 2 (Dimension) |
- |
|
|
|
| 5.2, Table 2 (Tolerance) |
- |
|
|
|
| 6.0 (HOLE TYPES) |
- |
|
|
|
| 7.1 (Central Hole) |
- |
|
|
|
| 7.2 (Pitch Circle Diameter -) |
- |
|
|
|
| 7.3 (Fixing Holes) |
- |
|
|
|
| 7.4, Table 3 (Nominal Size) |
- |
|
|
|
| 7.4, Table 3 (Thickness) |
- |
|
|
|
| 7.4, Table 3 (Centre hole diameter) |
- |
|
|
|
| 7.4, Table 3 (Pitch circle diameter) |
- |
|
|
|
| 7.4, Table 3 (No. Of holes) |
- |
|
|
|
| 8.1 (distortion) |
- |
|
|
|
| 8.2 (eccentricity) |
- |
|
|
|
| 8.3 (thickness of the cutting edge) |
- |
|
|
|
| 8.4 (cutting edge of discs) |
- |
|
|
|
| 9.0 (DESIGNATION) |
- |
|
|
|
| 10.0 (WORKMANSHIP AND FINISH) |
- |
|
|
|
|
- |
- Test facility is complete |
| 12370 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 2326 (1987) |
Automatic Flushing Cisterns for Urinals (Other than Plastic Cisterns) |
- |
1275 incl endu test + material as per ISS View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.0 (NOMINAL SIZE) |
- |
|
|
|
| 4.2 (Cistern ) |
- |
|
|
|
| 4.3 (Depth of Cistern Body) |
- |
|
|
|
| 4.4 (Siphonic Apparatus) |
- |
|
|
|
| 4.5 (Lid and Cover) |
- |
|
|
|
| 4.6 (Feeding Device -) |
- |
|
|
|
| 5.0 (FINISH) |
- |
|
|
|
| 6.1 (a) (Urinal Delivering capacity) |
- |
|
|
|
| 6.1 (b) (Flushing) |
- |
|
|
|
| 6.1 (c) (Discharge) |
- |
|
|
|
|
- |
- " 1 NO.
Excluding except for material test,external threading, finish and endurance test |
| 12371 |
BIS, Bengaluru Branch Laboratory (BNBL)
| None
| IS 252 (2013) |
Caustic soda - Specification (Fourth Revision) |
- |
Rs 5100/- (for Lye & Solid) View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3 (Form and Description) |
- |
|
|
|
| Cl. 3.3 and 3.4(Table 1, S. no i) (Sodium carbonate (as Na2CO3), percent by mass) |
- |
|
|
|
| Cl. 3.3 and 3.4(Table 1, S. no ii) (Sodium hydroxide (as NaOH), percent by mass) |
- |
|
|
|
| Cl. 3.3 and 3.4(Table 1, S. no iii) (Chlorides (as Cl– ), percent by mass) |
- |
|
|
|
| Cl. 3.3 and 3.4(Table 1, S. no iv) (Sulphates (as SO4), percent by mass) |
- |
|
|
|
| Cl. 3.3 and 3.4(Table 1, S. no v) (Silicates (as SiO2), percent by mass) |
- |
|
|
|
| Cl. 3.3 and 3.4(Table 1, S. no vi) (Iron (as Fe)) |
- |
|
|
|
| Cl. 3.3 and 3.4(Table 1, S. no vii) (Copper) |
- |
|
|
|
| Cl. 3.3 and 3.4(Table 1, S. no viii) (Manganese) |
- |
|
|
|
| Cl. 3.3 and 3.4(Table 1, S. no ix) (Chlorates and per-chlorates) |
- |
|
|
|
| Cl. 3.3 and 3.4(Table 1, S. no x) (Matter insoluble water, percent by mass) |
- |
|
|
|
| Cl. 3.3 and 3.4(Table 1, S. no xii) (Sodium hydroxide) |
- |
|
|
|
| Cl. 3.3 and 3.4(Table 1, S. no xi) (Total mercury) |
- |
|
|
|
|
- |
- - |
| 12372 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 5135 : Part 1 (1994) |
Specification for hand - Rotary duster: Part 1 belly - Mounted type (Second Revision) |
- |
Testing charges for the product are Rs 7600/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0 (Capacity) |
- |
|
|
|
| 8.0 (WORKMANSHIP AND FINISH) |
- |
|
|
|
|
- |
- Test facility not availabe |
| 12373 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 2326 (1987) |
Automatic Flushing Cisterns for Urinals (Other than Plastic Cisterns) |
- |
1275 incl endu test + material as per ISS View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.0 (NOMINAL SIZE) |
- |
|
|
|
| 4.2 (Cistern ) |
- |
|
|
|
| 4.3 (Depth of Cistern Body) |
- |
|
|
|
| 4.4 (Siphonic Apparatus) |
- |
|
|
|
| 4.5 (Lid and Cover) |
- |
|
|
|
| 4.6 (Feeding Device -) |
- |
|
|
|
| 5.0 (FINISH) |
- |
|
|
|
| 6.1 (a) (Urinal Delivering capacity) |
- |
|
|
|
| 6.1 (b) (Flushing) |
- |
|
|
|
| 6.1 (c) (Discharge) |
- |
|
|
|
|
- |
- Complete for Chemical, test facility not available for mechanical |
| 12374 |
BIS, Bengaluru Branch Laboratory (BNBL)
| None
| IS 1065 : Part 1 (2019) |
Stable bleaching powder - Specification: Part 1 household and industrial use (Third Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2 (Description) |
- |
|
|
|
| 5.3 Table-1 i (Available chlorine) |
- |
|
|
|
| 5.3 Table-1 ii (Stability, loss of
Chlorine on the basis of
initial available chlorine ) |
- |
|
|
|
| 5.3 Table-1 iiii (Moisture, percent by
mass.
) |
- |
|
|
|
| 5.3 Table-1 iv (Particle size (Passing
through 170 mm IS Sieve).
Percent by mass) |
- |
|
|
|
| Clause 5.4 (Keeping Quality ) |
- |
|
|
|
|
- |
- - |
| 12375 |
BIS, Central Laboratory (CL)
| None
| IS 366 (1991) |
Electric iron - Specification (Fourth Revision) |
- |
Rs.12300/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.0 (Classification (as per Cl.6 of IS 302-2-3 and Cl.6.1 of IS 302-1)) |
- |
|
|
|
| 7.0 (Classification (as per Cl.6 of IS 302-2-3 and Cl.6.2 of IS 302-1)) |
- |
|
|
|
| 9.0 (Protection against access to live parts (as per Cl. 8 of IS 302-2-3 and IS 302-1)) |
- |
|
|
|
| 9.0 (Power input and current (as per Cl. 10 of IS 302-2-3 and IS 302-1)) |
- |
|
|
|
| 9.0 (Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
|
|
|
| 9.0 (Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
|
|
|
| 9.0 (Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
|
|
|
| 9.0 (Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
|
|
|
| 9.0 (Leakage current and Electric Strength at Operating Temperature (as per Cl. 13 of IS 302-2-3 and IS 302-1)) |
- |
|
|
|
| 9.0 (Leakage current and Electric Strength at Operating Temperature (as per Cl. 13 of IS 302-2-3 and IS 302-1)) |
- |
|
|
|
| 9.0 (Moisture Resistance (as per of Cl.15 of IS 302-2-3 and IS 302-1)) |
- |
|
|
|
| 9.0 (Moisture Resistance (as per of Cl.15 of IS 302-2-3 and IS 302-1)) |
- |
|
|
|
| 9.0 (Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Staibilty and mechanical hazards (as per of Cl.20 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Mechanical strength (as per of Cl.21 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Components (as per of Cl.24 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Terminals for external conductors (as per of Cl.26 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 9.0 (Screw and connections (as per of Cl.28 of IS 302-2-3 and IS 302-1)) |
- |
|
|
|
| 9.0 (Screw and connections (as per of Cl.28 of IS 302-2-3 and IS 302-1)) |
- |
|
|
|
| 9.0 (Clearances, creepage distances and solid insulation (as per of Cl.29 of IS 302-2-3 and IS 302-1)) |
- |
|
|
|
| 9.0 (Clearances, creepage distances and solid insulation (as per of Cl.29 of IS 302-2-3 and IS 302-1)) |
- |
|
|
|
| 9.0 (Resistance to Heat and Fire (as per of Cl.30 of IS 302-2-3 and IS 302-1)) |
- |
|
|
|
| 9.0 (Resistance to Rusting (as per of Cl.31 of IS 302-2-3 and IS 302-1)) |
- |
|
|
|
| 10.0 (Measurement of Heating up time) |
- |
|
|
|
| 10.0 (Measurement of Heating up time) |
- |
|
|
|
| 11.0 (Measurement of sole plate temperature) |
- |
|
|
|
| 11.0 (Measurement of sole plate temperature) |
- |
|
|
|
| 11.0 (Measurement of sole plate temperature) |
- |
|
|
|
| 11.0 (Measurement of sole plate temperature) |
- |
|
|
|
| 12.0 (Measurement of Tempearture Distribution) |
- |
|
|
|
| 13.0 (Measurement of Initial overswing temperature and Heating up excess temperature) |
- |
|
|
|
| 13.0 (Measurement of Initial overswing temperature and Heating up excess temperature) |
- |
|
|
|
| 14.0 (Measurement of Cyclic fluctuation of temperature of hottest point ) |
- |
|
|
|
| 16.0 (Measurement of Thermostatic staibility) |
- |
|
|
|
| 16.0 (Measurement of Thermostatic staibility) |
- |
|
|
|
| 16.0 (Measurement of Thermostatic staibility) |
- |
|
|
|
| 16.0 (Measurement of Thermostatic staibility) |
- |
|
|
|
| 16.0 (Measurement of Thermostatic staibility) |
- |
|
|
|
| 9.0 (Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
|
|
|
| 9.0 (Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
|
|
|
| 6 (Measurement of Thermostatic staibility) |
- |
|
|
|
|
- |
- Exclusion : except Cordless Iron & Electronic circuit type iron(Cl.19.11 of IS 302 part 1), Steam iron with water reservoir |
| 12376 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 513 : Part 1 (2016) |
Cold reduced carbon steel sheet and strip: Part 1 cold forming and drawing purpose (Sixth Revision) |
- |
Rs.8850/- Excluding Tensile Strain Hardening component View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8 (Mechanical and Physical Properties) |
- |
|
|
|
| Cl 8 (UTM) |
- |
|
|
|
| Cl 9 (Workmanship) |
- |
|
|
|
| Cl 10 (Workmanship) |
- |
|
|
|
| Cl 11 (Length, Width & Thickness) |
- |
|
|
|
| 7.0 (CARBON) |
- |
|
|
|
| 7.0 (SULPHUR) |
- |
|
|
|
| 7.0 (SILICON) |
- |
|
|
|
| 7.0 (MANGANESE) |
- |
|
|
|
| 7.0 (PHOSPHORUS) |
- |
|
|
|
| 7.0 (NITROGEN) |
- |
|
|
|
| Cl. 11 (Out of square) |
- |
|
|
|
| Cl. 11 (Flatness) |
- |
|
|
|
| Cl. 11 (Camber) |
- |
|
|
|
| Cl. 11 (Width) |
- |
|
|
|
| Cl. 11 (Thickness) |
- |
|
|
|
| Cl. 8.4 (Bend Test) |
- |
|
|
|
| Cl. 8.3 Table 6 (Hardness Test
( Only for CR0 & CR1)) |
- |
|
|
|
| Cl. 8.1 & Table
5A, 5B & 5C (Elongation at 80 mm gauge length) |
- |
|
|
|
| Cl. 8.1 & Table
5A, 5B & 5C (Elongation at 50 mm gauge length) |
- |
|
|
|
| Cl. 8.1 & Table
5A, 5B & 5C (Yield Stress) |
- |
|
|
|
| Cl. 9 Table 8 (Surface roughness) |
- |
|
|
|
| 7.0 (ALUMINIUM) |
- |
|
|
|
| 7.0 (MICRO ALLOYS) |
- |
|
|
|
|
- |
- Excluding Finish (9.5), |
| 12377 |
BIS, Bengaluru Branch Laboratory (BNBL)
| None
| IS 15410 (2003) |
Containers for packaging of natural mineral water and packaged drinking water - Specification |
- |
5850 View breakup
Total charges = Rs.5850.00
Testing charges for material shall be levied as per relevant ISS.
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.6.2 (TRANSPARANCY) |
- |
|
|
|
| 4.6.3 (LEAKAGE TEST) |
- |
|
|
|
| 4.6.4 (DROP TEST) |
- |
|
|
|
| 4.6.6 (PORTABILITY TEST) |
- |
|
|
|
| 4.6.6 (chem) (Water Potability test (after 30 days) (a) Taste (b) Odour) |
- |
|
|
|
| 4.6.4, clause 8 of IS:2798:1998 (Drop test ) |
- |
|
|
|
| 4.6.3, clause 6 of IS:2798:1998 (Leakage test- c. Air pressure leakage) |
- |
|
|
|
| 4.6.3, clause 6 of IS:2798:1998 (Leakage test- b. Vibration leakage) |
- |
|
|
|
| 4.6.3, clause 6 of IS:2798:1998 (Leakage test- a. Closure leakage ) |
- |
|
|
|
| 4.6.2.1, Annex A (Transparency (Blue tint in polycarbonate & PET containers of 5 litre and above capacity)) |
- |
|
|
|
| 4.6.2 Annex A (Transparency) |
- |
|
|
|
| 4.5, IS:2798:1998 (Wall thickness- Bottom, in mm) |
- |
|
|
|
| Cl. 4.5 (Cl. 4.5 Wall Thickness (Middle)) |
- |
|
|
|
| Cl. 4.5 (Cl. 4.5 Wall Thickness (Top)) |
- |
|
|
|
| Cl. 4.4 (a) (Capacity) |
- |
|
|
|
| 4.3 (Workmanship, Finish & Appearance) |
- |
|
|
|
| 4.2 (Design, Shape & Dimension ) |
- |
|
|
|
| Cl. 4.5 (Cl. 4.5 Wall Thickness (Bottom)) |
- |
|
|
|
| Cl. 4.5 (Cl. 4.5 Wall Thickness (Middle)) |
- |
|
|
|
| Cl. 4.5 (Cl. 4.5 Wall Thickness (Top)) |
- |
|
|
|
| Cl. 4.4 (a) (Capacity) |
- |
|
|
|
| Cl. 4.3.2 (Cl. 4.3.2 Finish & Appearance) |
- |
|
|
|
| Cl. 4.2 (Cl. 4.2 Design, Shape & Dimension) |
- |
|
|
|
| Cl. 4.6.3 (Cl. 4.6.3 Air Pressure Leakage) |
- |
|
|
|
| Cl. 4.6.3 (Cl. 4.6.3 Vibration Leakage) |
- |
|
|
|
| Cl. 4.6.3 ( Cl. 4.6.3 Closure Leakage) |
- |
|
|
|
| 4.6.2.1, Annex-A (Transparency of container) |
- |
|
|
|
| 4.6.5.1 (chem) (Colour migration (Caps)) |
- |
|
|
|
| 4.6.5.1 (chem) (Colour migration (Container)) |
- |
|
|
|
| 4.6.5 , IS:9845:1998 (chem) (Migration of Caps - a. Amount of extractive) |
- |
|
|
|
| 4.6.5 , IS:9845:1998 (chem) (Migration- b. Amount of extractive) |
- |
|
|
|
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (i) (Barium) |
- |
|
|
|
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (ii) (Cobalt) |
- |
|
|
|
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (iii) (Copper) |
- |
|
|
|
| CL 4.6.7.2 and 4.6.7.3, Table 3 (iv) (Iron) |
- |
|
|
|
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (v) (Lithium) |
- |
|
|
|
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (vi) (Manganese) |
- |
|
|
|
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (vii) (Zinc) |
- |
|
|
|
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (viii) (Antimony) |
- |
|
|
|
|
- |
- Test facility not available for Pthalates |
| 12378 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 739 (1992) |
Wrought aluminium and aluminium alloys - Wire for general engineering purposes - Specification (Third Revision) |
- |
Rs.225/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0 (Freedom from defects) |
- |
|
|
|
| 7.0 (Dimension and Tolerances) |
- |
|
|
|
| 9.1 (Tensile Strength) |
- |
|
|
|
| 9.3 (Wrapping Test) |
- |
|
|
|
| 6.0 (Freedom from defects) |
- |
|
|
|
| 15.4 (b) (Cold impact) |
- |
|
|
|
| 9.1 (PIPE ENDS) |
- |
|
|
|
| 6.0 (Freedom from defects) |
- |
|
|
|
| 15.4 (b) (Cold impact) |
- |
|
|
|
| 9.1 (PIPE ENDS) |
- |
|
|
|
|
- |
- Facility for Chemical tests not available |
| 12379 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 4366 : Part 1 (1985) |
Specification for agricultural tillage discs: Part 1 concave type (Second Revision) |
- |
Rs 675/- View breakup
material test as per IS:9442
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.0 (MATERIAL) |
- |
|
|
|
| 5.0 (HARDNESS) |
- |
|
|
|
| 6.1, Table 1 (Nominal Size) |
- |
|
|
|
| 6.1, Table 1 (Thickness) |
- |
|
|
|
| 6.1, Table 1 (Concavity) |
- |
|
|
|
| 6.2, Table 2 (DISC SIZE) |
- |
|
|
|
| 6.2, Table 2 (EQUALLY SPACED NOTCH NUMBERS) |
- |
|
|
|
| 6.2, Table 2 (Notch Width) |
- |
|
|
|
| 6.2, Table 2 (Notch depth) |
- |
|
|
|
| 6.3, Table 3 (A) |
- |
|
|
|
| 6.3, Table 3 (M) |
- |
|
|
|
| 6.3, Table 3 (N) |
- |
|
|
|
| 6.3, Table 3 (P) |
- |
|
|
|
| 6.4 (Dimension) |
- |
|
|
|
| 7.0 (HOLE TYPES) |
- |
|
|
|
| 8.1 (Centre Square Hole) |
- |
|
|
|
| 8.2 (Circular Centre Hole with Keyway) |
- |
|
|
|
| 8.3 (Several Fixing Holes With or Without Circular Centre Hole) |
- |
|
|
|
| 9.1 (eccentricity and wobble) |
- |
|
|
|
| 9.2 (permanent deflection) |
- |
|
|
|
| 9.4 (thickness of the cutting edge) |
- |
|
|
|
| 8.4, Table 5 (DISC SIZE) |
- |
|
|
|
| 8.4, Table 5 (CENTRE SQUARE HOLE SIZE) |
- |
|
|
|
| 8.4, Table 5 (CENTRE Circular HOLE SIZE) |
- |
|
|
|
| 8.4, Table 5 (With bolt fixing, Centre hole diameter) |
- |
|
|
|
| 8.4, Table 5 (With bolt fixing, Pitch Circle Diameter) |
- |
|
|
|
| 8.4, Table 5 (With bolt fixing, Fixing hole size) |
- |
|
|
|
| 8.4, Table 5 (With bolt fixing, No. Of holes) |
- |
|
|
|
| 8.4, Table 5 (With rivet fixing, Centre hole diameter) |
- |
|
|
|
| 8.4, Table 5 (With rivet fixing, Pitch Circle Diameter) |
- |
|
|
|
| 8.4, Table 5 (With bolrivet fixing, Fixing hole size) |
- |
|
|
|
| 8.4, Table 5 (With rivet fixing, No. Of holes) |
- |
|
|
|
| 9.1, Table 6 (Nominal size) |
- |
|
|
|
| 9.1, Table 6 (ECCENTRICITY) |
- |
|
|
|
| 9.1, Table 6 (Wobble) |
- |
|
|
|
| 9.5 (cutting edge of the disc) |
- |
|
|
|
| 9.6 (Radius of concavity) |
- |
|
|
|
| 9.7 (Square holes) |
- |
|
|
|
| 9.8 (crown of the keyway) |
- |
|
|
|
| 9.9 (fixing holes) |
- |
|
|
|
| 10.0 (DESIGNATION) |
- |
|
|
|
| 11.0 (WORKMANSHIP AND FINISH) |
- |
|
|
|
|
- |
- Test facility is complete |
| 12380 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 2039 : Part 1 to 3 (1991) |
Steel tubes for bicycle and cycle rickshaws - Specification (Second Revision) |
- |
Rs.4320.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6.1 (Workmanship) |
- |
|
|
|
| Cl. 6.2 (Fin Height) |
- |
|
|
|
| Cl. 8.1 (Tensile Strength) |
- |
|
|
|
| Cl. 8.1 (Yield Strength) |
- |
|
|
|
| Cl. 8.1 (Elongation) |
- |
|
|
|
| Cl. 8.2 (Drift Expansion Test- IS 2335) |
- |
|
|
|
| Cl. 8.3 (Flattening Test-IS 2338) |
- |
|
|
|
| Cl. 9 (Diameter) |
- |
|
|
|
| Cl. 9 (Thickness) |
- |
|
|
|
| Cl. 3.2.1, Table 4 (Yield Stress) |
- |
|
|
|
| Cl. 3.2.1, Table 4 (UTS) |
- |
|
|
|
| Cl. 3.2.1, Table 4 (Elongation) |
- |
|
|
|
| Cl. 3.2.2, Table 2 (Drift Expansion Test- IS 2335) |
- |
|
|
|
| Cl. 3.2.3, Table 3 (Flattening Test-IS 2338) |
- |
|
|
|
| Cl. 4.2.1 (Diameter) |
- |
|
|
|
| Cl. 4.2.2 (Thickness) |
- |
|
|
|
| Cl. 4.2.3 (Length) |
- |
|
|
|
| Cl. 4.2.1, Table 7 (Yield Stress) |
- |
|
|
|
| Cl. 4.2.1, Table 7 (UTS) |
- |
|
|
|
| Cl. 4.2.2, Table 8 (Drift Expansion Test- IS 2335) |
- |
|
|
|
| Cl. 4.2.3, Table 9 (Flattening Test-IS 2338) |
- |
|
|
|
| Cl. 5.2.1, Table 10 (Diameter) |
- |
|
|
|
| Cl. 5.2.2 (Mean Thickness) |
- |
|
|
|
| Cl. 5.2.3, Table 6 (Length) |
- |
|
|
|
|
- |
- 1.5mx2
Excluding except drift expansion test, Tensile Test ,chemical test |
| 12381 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 737 (2008) |
Wrought aluminium and aluminium alloy sheet and strip for general engineering purposes - Specification (Fourth Revision) |
- |
Rs 8750/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.0 (Freedom from defects) |
- |
|
|
|
| 7 Table-2 (Tensile Strength) |
- |
|
|
|
| 7 Table-2 (Elongation) |
- |
|
|
|
| 7 Table-2 (Bend Test) |
- |
|
|
|
| 9.1 (PIPE ENDS) |
- |
|
|
|
| 15.4 (b) (Cold impact) |
- |
|
|
|
|
- |
- Excluding Proof stress, Facility for Chemical tests not available |
| 12382 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 16333 : Part 3 (2017) |
Mobile phone handsets: Part 3 indian language support for mobile phone handsets - Specific requirements (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1 (Inputting of text) |
- |
|
|
|
| 5.2 (Message Readability) |
- |
|
|
|
|
- |
- Test facility is complete |
| 12383 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 16008 : Part 2 (2016) |
Agro textiles “ Shade nets for agriculture and horticulture purposes “ Specification Part 2 Shade nets made from mono filament yarns (first revision) |
- |
22760.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.0(Material) |
- |
1050 |
|
Nil |
| 4.1(HDPE Mono filament) |
- |
2500.00 |
|
Nil |
| 4.1(HDPE Mono filament) |
- |
500.00 |
|
Nil |
| 4.1.1(HDPE Mono filament) |
- |
700.00 |
|
Nil |
| 4.2(Fabric) |
- |
500.00 |
|
Nil |
| 4.3(Colour) |
- |
300.00 |
|
Nil |
| 5.0(Types) |
- |
1000.00 |
|
Nil |
| 6.1(Dimensions and mass) |
- |
250.00 |
|
Nil |
| 6.2(Dimensions and mass) |
- |
250.00 |
|
Nil |
| 6.2 Table 1(Mass g/m2,Min) |
- |
250.00 |
|
Nil |
| 6.2 Table 1(Average breaking strength of shade nets fabric (Strip method,Warpway,Weftway
325 mm × 50 mm test piece with gauge length of 200 mm), N, Min
) |
- |
2200.00 |
|
Nil |
| 6.2 Table 1(Warpway Weftway) |
- |
2200.00 |
|
Nil |
| 6.2 Table 1(Retention of breaking strength after UV exposure, N, Min) |
- |
8260.00 |
|
- |
| 6.2 Table 1(Colour fastness to artificial light1) |
- |
850.00 |
|
Nil |
| 6.2 Table 1(Bursting pressure, kgf/cm2, Min) |
- |
1000.00 |
|
Nil |
| 6.2 Table 1(Shading %) |
- |
700.00 |
|
Nil |
|
31 Dec, 2026 |
- - |
| 12384 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 16415 (2015) |
Composite cement - Specification |
- |
Rs.9150/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 -Table - 2 i (Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
|
|
|
| 6 -Table - 2 ii (Magnesia - Cl 4.8 of IS 4032:1985) |
- |
|
|
|
| 6 -Table - 2 iii (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
|
|
|
| 6 -Table - 2 iv (Sulphide sulphur (S) - Cl 6.12 of IS 4032:1985) |
- |
|
|
|
| 6 -Table - 2 v (Loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
|
|
|
| 6 -Table - 2 vi (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
| 7 and Table 3 i (Fineness
IS 4031(Part 2)) |
- |
|
|
|
| 7 and Table 3 ii a (Soundness, Le-Chate1ier expansion
IS 4031(Part 3) ) |
- |
|
|
|
| 7 and Table 3 ii b (Soundness, Autoclave expansion
IS 4031(Part 3) ) |
- |
|
|
|
| 7 and Table 3 iii a (Setting Time ( by Vicat Apparatus), Initial
IS 4031(Part 5)) |
- |
|
|
|
| 7 and Table 3 iii b (Setting Time ( by Vicat Apparatus ), Final
IS 4031(Part 5)) |
- |
|
|
|
| 7 and Table 3 iv a (Compretsive Strenqth .72 ± 1 hr
IS 4031(Part 6)) |
- |
|
|
|
| 7 and Table 3 iv b (Compretsive Strenqth 168 ± 2 hr
IS 4031(Part 6)) |
- |
|
|
|
| 7 and Table 3 iv c (Compretsive Strenqth 672 ± 4 hr
IS 4031(Part 6)) |
- |
|
|
|
| 7 and Table 3 v (Drying shrinkage
IS 4031(Part 10)) |
- |
|
|
|
| Cl. 6.1,Table 2 (Alkali content) |
- |
|
|
|
| 7 and Table 3 vi (Transverse strength (optional)
IS 4031(Part 8) ) |
- |
|
|
|
|
- |
- Mech - Except Transverse Strength (optional),
Chem-Declaration for chloride regarding end use of cement (as per Table 1) and declaration of fly ash content & Confirmation for testing Alkali Content required. |
| 12385 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 808 (1989) |
Dimensions for hot rolled steel beam, column, channel and angle sections (Third Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7, 8, Table 2.1 (Mass) |
- |
|
|
|
| 7, 8, Table 2.1 (Dimensions, D) |
- |
|
|
|
| 7, 8, Table 2.1 (Dimensions, B) |
- |
|
|
|
| 7, 8, Table 2.1 (Dimensions, t) |
- |
|
|
|
| 7, 8, Table 2.1 (Dimensions, T) |
- |
|
|
|
| 7, 8, Table 2.1 (Dimensions, Flange Slope) |
- |
|
|
|
| 7, 8, Table 2.1 (Dimensions, R1) |
- |
|
|
|
| 7, 8, Table 2.1 (Dimensions, R2) |
- |
|
|
|
| 7, 8, Table 2.2 (Mass) |
- |
|
|
|
| 7, 8, Table 2.2 (Dimensions, D) |
- |
|
|
|
| 7, 8, Table 2.2 (Dimensions, B) |
- |
|
|
|
| 7, 8, Table 2.1 (Dimensions, t) |
- |
|
|
|
| 7, 8, Table 2.2 (Dimensions, T) |
- |
|
|
|
| 7, 8, Table 2.2 (Dimensions, Flange Slope) |
- |
|
|
|
| 7, 8, Table 2.2 (Dimensions, R1) |
- |
|
|
|
| 7, 8, Table 3.1 (Mass) |
- |
|
|
|
| 7, 8, Table 4.1 (Mass) |
- |
|
|
|
| 7, 8, Table 5.1 (Mass) |
- |
|
|
|
| 7, 8, Table 6.1 (Mass) |
- |
|
|
|
| 7, 8, Table 6.2 (Mass) |
- |
|
|
|
| 7, 8, Table 3.1 (Dimensions, D) |
- |
|
|
|
| 7, 8, Table 3.1 (Dimensions, B) |
- |
|
|
|
| 7, 8, Table 3.1 (Dimensions, T) |
- |
|
|
|
| 7, 8, Table 3.1 (Dimensions, Flange Slope) |
- |
|
|
|
| 7, 8, Table 3.1 (Dimensions, R1) |
- |
|
|
|
| 7, 8, Table 3.1 (Dimensions, R2) |
- |
|
|
|
| 7, 8, Table 4.1 (Dimensions, D) |
- |
|
|
|
| 7, 8, Table 4.1 (Dimensions, B) |
- |
|
|
|
| 7, 8, Table 4.1 (Dimensions, t) |
- |
|
|
|
| 7, 8, Table 4.1 (Dimensions, T) |
- |
|
|
|
| 7, 8, Table 4.1 (Dimensions, Flange Slope) |
- |
|
|
|
| 7, 8, Table 4.2 (Dimensions, R1) |
- |
|
|
|
| 7, 8, Table 4.1 (Dimensions, R2) |
- |
|
|
|
| 7, 8, Table 4.2 (Dimensions, D) |
- |
|
|
|
| 7, 8, Table 4.2 (Dimensions, B) |
- |
|
|
|
| 7, 8, Table 4.2 (Dimensions, t) |
- |
|
|
|
| 7, 8, Table 4.2 (Dimensions, T) |
- |
|
|
|
| 7, 8, Table 4.2 (Dimensions, R1) |
- |
|
|
|
|
- |
- Excluding Microalloying Elements |
| 12386 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 4351 (2003) |
Steel Door Frames - |
- |
Please see remarks. View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5, Table 1 (Mild steel sheet (cold rolled)) |
- |
|
|
|
| 5, Table 1 (Galvanized steel sheets — Plain grade — Lock forming (GPL), Zinc coating 120 g/m2 inchssive of both sides) |
- |
|
|
|
| 5, Table 1 (Stainless steel Grade — X07Crl 7 (430) X04Cr19N;; (304 S1 )) |
- |
|
|
|
| 6.1 (Sizes) |
- |
|
|
|
| 6.3 (Designation) |
- |
|
|
|
| 7, Table 2 (Profile) |
- |
|
|
|
| 7, Table 2 (Size, X) |
- |
|
|
|
| 7, Table 2 (Size, Y) |
- |
|
|
|
| 7, Table 2 (Rebate) |
- |
|
|
|
| 8.0 (CONSTRUCTION) |
- |
|
|
|
| 9.0 (BASE TIES) |
- |
|
|
|
| 10.1 (Fixing Lugs (Holdfasts)) |
- |
|
|
|
| 10.2, Table 3 (Steel butt hinge— medium weight) |
- |
|
|
|
| 10.2, Table 3 (Stainless steel butt hinges medium weight) |
- |
|
|
|
| 10.2, Table 3 (Non-ferrous metal butt hinges) |
- |
|
|
|
| 10.2, Table 3 (Mild steel parliament hinges) |
- |
|
|
|
| 10.2, Table 3 (Mild steel light weight tee hinges) |
- |
|
|
|
| 10.3 (Mortar Guards) |
- |
|
|
|
| 10.4 (Aldrops, Sliding Bolts and Tower Bolts) |
- |
|
|
|
| 10.5 (Lock Strike Plate) |
- |
|
|
|
| 10.6 (Shock Absorbers) |
- |
|
|
|
|
- |
- Excluding Microalloying Elements |
| 12387 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 15410 (2003) |
Containers for packaging of natural mineral water and packaged drinking water - Specification |
For all capacity |
5850 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.6.2 (TRANSPARANCY) |
- |
|
|
|
| 4.6.3, clause 6 of IS:2798:1998 (Leakage test- a. Closure leakage ) |
- |
|
|
|
| 4.6.3, clause 6 of IS:2798:1998 (Leakage test- c. Air pressure leakage) |
- |
|
|
|
| 4.6.4 (DROP TEST) |
- |
|
|
|
| 4.6.6 (PORTABILITY TEST) |
- |
|
|
|
| 4.6.3, clause 6 of IS:2798:1998 (Leakage test- b. Vibration leakage) |
- |
|
|
|
| 4.5, IS:2798:1998 (Wall thickness- Bottom, in mm) |
- |
|
|
|
| 4.5, IS:2798:1998 (Wall thickness- Middle , in mm) |
- |
|
|
|
| 4.5, IS:2798:1998 (Wall thickness- Top , in mm ) |
- |
|
|
|
| 4.4 , clause 5 of IS:2798:1998 (Brimful capacity in ml) |
- |
|
|
|
| 4.3 (Workmanship, Finish & Appearance) |
- |
|
|
|
| 4.2 (Design, Shape & Dimension ) |
- |
|
|
|
| 4.0 (chem) (MATERIAL) |
- |
|
|
|
| Cl. 4.6.5 (chem) (Cl. 4.6.5 Overall migration (Caps)) |
- |
|
|
|
| 4.6.5.1 (chem) (Colour migration (Caps)) |
- |
|
|
|
| 4.6.5.1 (chem) (Colour migration (Container)) |
- |
|
|
|
| Cl. 4.6.5 (Overall migration for container) |
- |
|
|
|
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(i) (Specific migration for Cap,Barium) |
- |
|
|
|
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(ii) (Specific migration for Cap,Cobalt) |
- |
|
|
|
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(iii) (Specific migration for Cap,Copper) |
- |
|
|
|
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(iv) (Specific migration for Cap,Iron) |
- |
|
|
|
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(v) (Specific migration for Cap,Lithium) |
- |
|
|
|
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(vi) (Specific migration for Cap,Manganese) |
- |
|
|
|
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(vii) (Specific migration for Cap,Zinc) |
- |
|
|
|
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(viii) (Specific migration for Cap,Antimony) |
- |
|
|
|
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(ix) ("Specific migration for Cap,Phthalic acid, bis(2-ethylhexyl)
ester (DEHP)") |
- |
|
|
|
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (i) (Barium) |
- |
|
|
|
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (ii) (Cobalt) |
- |
|
|
|
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (iii) (Copper) |
- |
|
|
|
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (iv) (Iron) |
- |
|
|
|
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (v) (Lithium) |
- |
|
|
|
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (vi) (Manganese) |
- |
|
|
|
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (vii) (Zinc) |
- |
|
|
|
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (viii) (Antimony) |
- |
|
|
|
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (ix) (Phthalic acid, bis(2-ethylhexyl) ester (DEHP)) |
- |
|
|
|
| 4.1 (Material) |
- |
|
|
|
| Cl. 4.6.5 (chem) (Cl. 4.6.5 Color migration (Caps)) |
- |
|
|
|
| Cl. 4.6.5 (Cl. 4.6.5 Migration) |
- |
|
|
|
| 4.6.5.1.b (Colour migration Test (Cap)) |
- |
|
|
|
| 4.6.5.1.a (Colour migration Test (Container)) |
- |
|
|
|
| CL 4.6.7.2 and 4.6.7.3, Table 3 (i) (Barium) |
- |
|
|
|
| CL 4.6.7.2 and 4.6.7.3, Table 3 (ii) (Cobalt) |
- |
|
|
|
| CL 4.6.7.2 and 4.6.7.3, Table 3 (iii) (Copper) |
- |
|
|
|
| CL 4.6.7.2 and 4.6.7.3, Table 3 (iv) (Iron) |
- |
|
|
|
| CL 4.6.7.2 and 4.6.7.3, Table 3 (v) (Lithium) |
- |
|
|
|
| CL 4.6.7.2 and 4.6.7.3, Table 3 (vi) (Manganese) |
- |
|
|
|
| CL 4.6.7.2 and 4.6.7.3, Table 3 (vii) (Zinc) |
- |
|
|
|
| CL 4.6.7.2 and 4.6.7.3, Table 3 (viii) (Antimony) |
- |
|
|
|
| CL 4.6.7.2 and 4.6.7.3, Table 3 (ix) (Phthalic acid, bis(2-ethylhexyl) ester (DEHP)) |
- |
|
|
|
| 4.1 (Material) |
- |
|
|
|
| 4.6.5 (Migration Test) |
- |
|
|
|
| Clauses 5.3.9.2 and 5.3.9.3,Table 3, S.no.(ix) (Phthalic acid, bis(2-ethylhexyl)ester (DEHP)-ISO 18856) |
- |
|
|
|
| Cl. 4.1 (Material test for container) |
- |
|
|
|
| Cl. 4.6.5.1 (Colour migration for container) |
- |
|
|
|
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(i) (Specific migration for container,Barium) |
- |
|
|
|
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(ii) (Specific migration for container,Cobalt) |
- |
|
|
|
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(iii) (Specific migration for container,Copper) |
- |
|
|
|
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(iv) (Specific migration for container,Iron) |
- |
|
|
|
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(v) (Specific migration for container,Lithium) |
- |
|
|
|
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(vi) (Specific migration for container,Manganese) |
- |
|
|
|
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(vii) (Specific migration for container,Zinc) |
- |
|
|
|
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(viii) (Specific migration for container,Antimony) |
- |
|
|
|
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(ix) ("Specific migration for container,Phthalic acid, bis(2-ethylhexyl)
ester (DEHP)") |
- |
|
|
|
| Cl. 4.6.5 (Overall migration for Cap) |
- |
|
|
|
| Cl. 4.6.5.1 (Colour migration for Cap) |
- |
|
|
|
| 5 (Marking) |
- |
|
|
|
| 5 (Packing and Marking) |
- |
|
|
|
|
- |
- Material test being done for PET only. |
| 12388 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 7283 (1992) |
Hot - Rolled bars for the production of bright bars and machined parts for engineering applications specification (First Revision) |
- |
Rs 1500/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 6 (Workmanship) |
- |
|
|
|
| Cl 7 (Diameter & Out Of Round) |
- |
|
|
|
| Cl 11 (Size) |
- |
|
|
|
| Cl 6 (Workmanship) |
- |
|
|
|
| 5, 5.1, 5.2 (Chemical Composition - Carbon) |
- |
|
|
|
| 5, 5.1, 5.2 (Chemical Composition - Sulphur) |
- |
|
|
|
| 5, 5.1, 5.2 (Chemical Composition - Phosphorus) |
- |
|
|
|
| 5, 5.1, 5.2 (Chemical Composition - Manganese) |
- |
|
|
|
| 5, 5.1, 5.2 (Chemical Composition - Silicon) |
- |
|
|
|
|
- |
- Excluding Decarburization, Hardenability test, Inclusion rating and grain size, Microalloying Elements |
| 12389 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 17048 (2018) |
Halogen free flame retardant (HFFR) cables for working voltages up to and including 1 100 Volts - Specification |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1 a) (Conductor : Material ) |
- |
|
|
|
| 4.1.1 b) (Material : Seperator tape ) |
- |
|
|
|
| 4.1.1 d) , 11.1, 12.1, 13.1,14.1 (Class of conductor ) |
- |
|
|
|
| 4.1.1 e) (Shape of conductor ) |
- |
|
|
|
| 4.1.1 f) (Nominal size of conductor ) |
- |
|
|
|
| 4.2.1, 11.2, 12.2, 13.2, 14.2 (Insulation : Material ) |
- |
|
|
|
| 4.2.2, 11.2, 12.2, 13.2, 14.2 (Insulation : Application ) |
- |
|
|
|
| 4.2.3,11.2, 12.2, 13.2 (Thickness of insulation - Avearge : IS 10810 ( Part 6 )) |
- |
|
|
|
| 4.2.3, 11.2, 12.2, 13.2, 14.2 (Thickness of insulation - miniumum : IS 10810 ( Part 6 )) |
- |
|
|
|
| 4.2.4 (Insulation : Tensile stregth ( Before ageing)-IS 10810 (Part 7) ) |
- |
|
|
|
| 4.2.4 (Insulation : Elongation ( Before ageing) -IS 10810 (Part 7)) |
- |
|
|
|
| 4.2.4 (Insulation : Tensile stregth ( After ageing) - IS 10810 (Part 7) ) |
- |
|
|
|
| 4.2.5 (Insulation : Tensile stregth variation ( After ageing) - IS 10810 (Part 7) ) |
- |
|
|
|
| 4.2.4 (Insulation : Elongation (after ageing) - IS 10810 (Part 7) ) |
- |
|
|
|
| 4.2.5 (Insulation : Elongation variation (after ageing) - IS 10810 (Part 7) ) |
- |
|
|
|
| 4.3 (Fillers) |
- |
|
|
|
| 4.4 (Binder Tape) |
- |
|
|
|
| 4.5.1,13.4, 14.4 (Sheath : Compound ) |
- |
|
|
|
| 4.5.2, 13.4, 14.4 (Sheath : Application) |
- |
|
|
|
| 4.5.3,13.4, 14.4 (Thickness of sheath - Average : IS 10810 (Part 6)) |
- |
|
|
|
| 4.5.3,13.4, 14.4 (Thickness of sheath - Minimum : IS 10810 (Part 6)) |
- |
|
|
|
| 4.5.4, 13.4 (Sheath : Tensile stregth ( Before ageing)-IS 10810 (Part 7) ) |
- |
|
|
|
| 4.5.4,13.4 (Sheath : Elongation ( Before ageing) -IS 10810 (Part 7)) |
- |
|
|
|
| 4.5.5, 13.4,14.4 (Sheath : Elongation variation (after ageing) - IS 10810 (Part 7) ) |
- |
|
|
|
| 4.5.5, 11.3, 12.3, 13.6, 14.6 (Overall Dimensions) |
- |
|
|
|
| 4.5.5.1, 11.3, 12.3,13.5, 14.5 (Ovality) |
- |
|
|
|
| 4.5.6, 13.4 (Colour of Sheath) |
- |
|
|
|
| 5.1 (High Voltage Test (at Room Temperature)) |
- |
|
|
|
| 5.3 (Flammability Test- IS 10810 (Part 53).) |
- |
|
|
|
| 5.4 (Oxygen Index Test- IS 10810 (Part 58)) |
- |
|
|
|
| 5.5 (Temperature Index-IS 10810 (Part 64).) |
- |
|
|
|
| 5.11 (Flame Retardant Test- IS 10810 (Part 61),) |
- |
|
|
|
| 5.12 (Hot Set Test- IS 10810 (Part 30).) |
- |
|
|
|
| 5.12 (Permanent Set - IS 10810 (Part 30).) |
- |
|
|
|
| 5.15 (Cold Bend Test-IS 10810 (Part 20).) |
- |
|
|
|
| 5.16 (Cold Impact Test- IS 10810 (Part 21).) |
- |
|
|
|
| 6.1, Table 1 (CORE IDENTIFICATION) |
- |
|
|
|
| 6.2 (Core Identification by Numbers) |
- |
|
|
|
| 6.2.2 (Durability) |
- |
|
|
|
| 7.0 (CABLE CODE) |
- |
|
|
|
| 9.0 ( IDENTIFICATION) |
- |
|
|
|
| 10.1 (Packing ) |
- |
|
|
|
| 10.2 (marking) |
- |
|
|
|
| 10.2.1 (Standards marking) |
- |
|
|
|
| 13.3, 14.3 (assembly of cores ) |
- |
|
|
|
| 5.6 (Smoke Density-IS 10810 (Part 63).) |
- |
|
|
|
| 4.5.4, 13.4, 14.4 (Sheath : Tensile stregth ( After ageing) - IS 10810 (Part 7) ) |
- |
|
|
|
| 4.5.5, 13.4, 14.4 (Sheath : Tensile stregth variation ( After ageing) - IS 10810 (Part 7) ) |
- |
|
|
|
| 4.5.4, 13.4, 14.4 (Sheath : Elongation (after ageing) - IS 10810 (Part 7) ) |
- |
|
|
|
| 4.5.5, 13.4,14.4 (Sheath : Elongation variation (after ageing) - IS 10810 (Part 7) ) |
- |
|
|
|
| 5.13 (Water Immersion Test (Effect of Water on Sheath) : Tensile strength -IS 10810 (Part 7).) |
- |
|
|
|
| 5.13 (Water Immersion Test (Effect of Water on Sheath) : Elogation -IS 10810 (Part 7).) |
- |
|
|
|
|
- |
- Excluding Except Assessment of halogen (Cl. 5.7), Water immersion test (Cl. 5.13) |
| 12390 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 16008 : Part 1 (2016) |
Agro textiles “ Shade nets for agriculture and horticulture purposes “ Specification Part 1 Shade nets made from tape yarns (first revision) |
- |
22760.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.0(Types) |
- |
1000.00 |
|
Nil |
| 6.1(Dimensions and Mass - IS 1954) |
- |
250 |
|
Nil |
| 6.1(Dimensions and Mass - IS 1954) |
- |
250 |
|
Nil |
| 6.2 Table 1(Mass - IS 1964) |
- |
250 |
|
Nil |
| 6.2 Table 1(Average breaking strength of shade nets fabric (Strip method, 325 mm x 50 mm test piece with gauge length of 200 mm) - IS 1969 (Part 1)) |
- |
2200 |
|
Nil |
| 6.2 Table 1(Average breaking strength of shade nets fabric (Strip method, 325 mm x 50 mm test piece with gauge length of 200 mm) - IS 1969 (Part 1)) |
- |
2200 |
|
Nil |
| 6.2 Table 1(Retention of breaking strength after UV exposure - IS 1969 (Part 1)) |
- |
8260 |
|
25% discount is not application in conditioning charges |
| 6.2 Table 1(Colour fastness to artificial light, IS 2454) |
- |
850 |
|
Nil |
| 6.2 Table 1(Bursting Pressure, IS 1966 (Part 1 or 2)) |
- |
1000 |
|
Nil |
| 6.2 Table 1(Shading Percentage) |
- |
700 |
|
Nil |
|
31 Dec, 2026 |
- - |