| 12601 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 7834 : Part 6 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 6 Specific requirements for sockets |
- |
7294 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.1(General) |
- |
1050 |
|
- |
| 2.2(Manufacture) |
- |
1050 |
|
- |
| 2.2.2, Table 1(Size) |
- |
0 |
|
- |
| 2.2.2, Table 1(Socket Laying
Length) |
- |
250 |
|
- |
| 2.2.3( inside diameter of the socket) |
- |
500 |
|
- |
| 2.2.3(Socket length) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 12602 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 7834 : Part 7 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 7 Specific requirements for unions |
- |
7294 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.1(General) |
- |
1050 |
|
- |
| 2.2(Manufacture) |
- |
1050 |
|
- |
| 2.2.2, Table 1(Size) |
- |
0 |
|
- |
| 2.2.2, Table 1(Union Laying
Length) |
- |
250 |
|
- |
| 2.2.3( inside diameter of the socket) |
- |
500 |
|
- |
| 2.2.3(Socket length) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 12603 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 7834 : Part 8 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 8 Specific requirements for caps |
- |
- View breakup
Rs.4219/-,
Rs.3075/- PVC Resin
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
31 Dec, 2026 |
- - |
| 12604 |
DELHI TEST HOUSE, Azadhpur
| 8131406
| IS 7834 : Part 1 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 1 General requirements |
- |
5200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.4(Minimum Thickness) |
- |
250 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 5.1.1, 5.1.2, Table 1, Fig 1(Minimum Socket Length) |
- |
200 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 5.1.1, 5.1.2, Table 1, Fig 1(Mean Socket Internal Diameter at Mid-Point of Socket Length) |
- |
200 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 5.1.1, 5.1.2, Table 1, Fig 1(Out-of-roundness tolerances of socket inside diameter) |
- |
200 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 6.1(Stress Relief Test- Appendix A) |
- |
750 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 6.2(Opacity- Appendix B) |
- |
750 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 6.3(Effect on Water[(Lead ( first extraction )]- Appendix C) |
- |
250 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 6.3(Effect on Water[(Lead ( third extraction )]- Appendix C) |
- |
250 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 6.3(Effect on Water [Dialkyl tin C4, and higher homologues, measured as tin ( third extraction )]- Appendix C) |
- |
500 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 6.3(Effect on Water [Other toxic substances ( third extraction )]- Appendix C) |
- |
1000 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 6.4(Short-Term Hydraulic Test- Appendix D) |
- |
1200 |
|
For BIS samples 1.5 times of BIS testing charges |
|
17 Jun, 2027 |
- - |
| 12605 |
Bharat Test House Pvt Ltd 1474 Sonipat Haryana
| 9135626
| IS 10322 : Part 5 : Sec 4 (1987) |
Specification for luminaires: Part 5 particular requirements: Sec 4 portable general purpose luminaires |
Portable General Purpose Luminaires |
42000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
500 |
|
5% discount for BIS |
| 6(Construction) |
- |
4500 |
|
5% discount for BIS |
| 7(Creepage Distance
And Clearances) |
- |
1000 |
|
5% discount for BIS |
| 8(Provision for
Earthing) |
- |
1000 |
|
5% discount for BIS |
| 9(Terminals) |
- |
3000 |
|
5% discount for BIS |
| 10(External &
Internal Wiring) |
- |
2000 |
|
5% discount for BIS |
| 11(Protection Against
Electric Shock ) |
- |
1000 |
|
5% discount for BIS |
| 13.3(Mechanical
Strength Test ) |
- |
3000 |
|
5% discount for BIS |
| 13.4(Endurance Test
and Thermal test) |
- |
3000 |
|
5% discount for BIS |
| 13.5(Resistance To
Dust & Moisture) |
- |
3000 |
|
5% discount for BIS |
| 13.6(Insulation Resistance
and Electric Strength) |
- |
3000 |
|
5% discount for BIS |
| 13.7(Resistance to Heat,
Fire & Tracking) |
- |
3000 |
|
5% discount for BIS |
| 13.8(Photometric Test) |
- |
14000 |
|
5% discount for BIS |
|
19 Mar, 2026 |
- - |
| 12606 |
DELHI TEST HOUSE, Azadhpur
| 8131406
| IS 447 (1988) |
Specification for rubber hose for welding (Fourth Revision) |
- |
10000 View breakup
For BIS samples: 1.5 times of BIS testing charges, For others
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 3.2 - Table 1(Bore size) |
- |
500 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 3.3 - Table 2(Tensile strength - Lining MPA) |
- |
4000 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 3.4 - Table3(Pressure Tests) |
- |
5000 |
|
For BIS samples 1.5 times of BIS testing charges |
|
17 Jun, 2027 |
- - |
| 12607 |
NATIONAL TEST HOUSE (SOUTHERN REGION) - NTH, CHENNAI
| 6122704
| IS 1554 : Part 2 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 2 for working voltages from 3.3 kV up to and including 11 kV (Second Revision) |
Earthed & Unearthed Cables |
24500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(CONDUCTOR) |
- |
600 |
|
- |
| 4.1(INSULATION) |
- |
600 |
|
- |
| 5.1(SCREENING) |
- |
600 |
|
- |
| 6.1(FILLERS AND INNER SHEATH) |
- |
600 |
|
- |
| 7.1(ARMOURING) |
- |
600 |
|
- |
| 8.1(OUTER SHEATH) |
- |
600 |
|
- |
| 9.1(CONDUCTOR) |
- |
1000 |
|
- |
| 11.1(INSULATION) |
- |
1000 |
|
- |
| 11.2(INSULATION : Thickness of Insulation) |
- |
1000 |
|
- |
| 13.1(CORE IDENTIFICATION) |
- |
600 |
|
- |
| 14.1(LAYING UP OF CORES) |
- |
1000 |
|
- |
| 15.1(INNER SHEATH (COMMON COVERING)) |
- |
1000 |
|
- |
| 15.4(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
1000 |
|
- |
| 15.4.1(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
1000 |
|
- |
| 16.1.1(ARMOURING : Application) |
- |
1000 |
|
- |
| 16.1.3(ARMOURING : Direction of lay ) |
- |
1000 |
|
- |
| 16.3(Armouring : Dimensions -Wire Diameter) |
- |
1000 |
|
- |
| 16.4(ARMOURING : Joints) |
- |
1000 |
|
- |
| 16.5(ARMOURING : Resistance) |
- |
1000 |
|
- |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
1000 |
|
- |
| 13.6 b)(ARMOURING: Elongation ) |
- |
1000 |
|
- |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
1000 |
|
- |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
1000 |
|
- |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
1000 |
|
- |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
1000 |
|
- |
| 13.6 g)(ARMOURING: Resistivity) |
- |
1000 |
|
- |
| 17.1(OUTER SHEATH) |
- |
1000 |
|
- |
| 17.3.1(Thickness of Outer Sheath : Unarmoured Cables) |
- |
1000 |
|
- |
| 17.3.2(Thickness of Outer Sheath : Armoured Cables) |
- |
1000 |
|
- |
| 18.1 a) 1)(Tests on Conductor : Annealing test (for copper)) |
- |
1000 |
|
- |
| 18.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
1000 |
|
- |
| 18.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
1000 |
|
- |
| 18.1 a) 3)(Tests on Conductor : Wrapping test ( for aluminium)) |
- |
1000 |
|
- |
| 18.1 a)4)(Tests on conductor : Conductor resistance test - Main conductor ) |
- |
1000 |
|
- |
| 18.1 a)4)(Resistance test - Neutral conductor ) |
- |
1000 |
|
- |
| 18.1 d) 1)(Phyaical tests for insulation : Tensile Test) |
- |
1000 |
|
- |
| 18.1 d) 1)(Phyaical tests for insulation : Elongation ) |
- |
1000 |
|
- |
| 18.1 d) 1)(Physical tests for sheath : Tensile stregth ) |
- |
1000 |
|
- |
| 18.1 d) 1)(Physical tests for sheath : Elongation ) |
- |
1000 |
|
- |
| 18.1 d) 2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
1000 |
|
- |
| 18.1 d) 2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
1000 |
|
- |
| 18.1 d) 2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
1000 |
|
- |
| 18.1 d) 2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
1000 |
|
- |
| 18.1 d) 3)(Phyaical tests for insulation : Shrinkage ) |
- |
1000 |
|
- |
| 18.1 d) 3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
1000 |
|
- |
| 18.1 d) 4)(Hot deformation : Insulation ) |
- |
1000 |
|
- |
| 18.1 d) 4)(Hot deformation : Sheath ) |
- |
1000 |
|
- |
| 18.1 d) 5)( Loss of mass in air oven- Insulation ) |
- |
1000 |
|
- |
| 18.1 d) 5)( Loss of mass in air oven- sheath ) |
- |
1000 |
|
- |
| 18.1 d) 6)(Heat shock test- Insulation ) |
- |
1000 |
|
- |
| 18.1 d) 7)(Thermal stability- insulation ) |
- |
1000 |
|
- |
| 18.1 d) 7)(Thermal stability- Sheath ) |
- |
1000 |
|
- |
| 18.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
1000 |
|
- |
| 18.1 e)(Insulation resistance test : IR Constant ) |
- |
1000 |
|
- |
| 19.7(High voltage test) |
- |
1000 |
|
- |
| 19.8(Flammability test) |
- |
1000 |
|
- |
| 19.11(Flame Retardance Test on Bunched Cables) |
- |
5000 |
|
- |
| 19.10(Flame Retardance Test on Single Cables) |
- |
5000 |
|
- |
| 19.13(Test for Halogen Acid Gas Evolution) |
- |
5000 |
|
- |
| 19.9(Oxygen Index Test) |
- |
5000 |
|
- |
| 19.14(Temperature Index) |
- |
5000 |
|
- |
| 18.4(Optional Test : Cold Impact ) |
- |
1000 |
|
- |
| 20.2(IDENTIFICATION : Cable Identification) |
- |
0 |
|
- |
|
28 Nov, 2028 |
- - |
| 12608 |
NATIONAL TEST HOUSE (SOUTHERN REGION) - NTH, CHENNAI
| 6122704
| IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
22000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(CONDUCTOR: MATERIALS) |
- |
500 |
|
- |
| 4(INSULATION : MATERIALS) |
- |
500 |
|
- |
| 5.1(FILLER AND INNER SHEATH) |
- |
500 |
|
- |
| 6(ARMOURING) |
- |
500 |
|
- |
| 7(OUTER SHEATH) |
- |
500 |
|
- |
| 8.1(CONDUCTOR: CONSTRUCTION) |
- |
500 |
|
- |
| 8.2(PROTECTIVE BARRIER) |
- |
500 |
|
- |
| 8.3(SIZE OF NEUTRAL CONDUCTOR) |
- |
500 |
|
- |
| 9.1(Insulation Applied by extrusicn) |
- |
500 |
|
- |
| 9.2(Thickness of Insulation - Average) |
- |
500 |
|
- |
| 9.3(Thickness of Insulation - Minimum) |
- |
500 |
|
- |
| 9.4(Application of Insulation) |
- |
500 |
|
- |
| 10.1(Core Identification) |
- |
500 |
|
- |
| 10.2(Core Identification- Neutral) |
- |
500 |
|
- |
| 10.3(Core Identification by number ) |
- |
500 |
|
- |
| 10.4(Core Identification by number - Neutral ) |
- |
500 |
|
- |
| 11(LAVING UP OF CORES) |
- |
500 |
|
- |
| 12.1 & 12.2(Inner sheath : Application) |
- |
500 |
|
- |
| 12.3(Thickness of Inner Sheath) |
- |
500 |
|
- |
| 13.1(Armouring: Application) |
- |
500 |
|
- |
| 13.1.2(Armouring: Coverage ) |
- |
500 |
|
- |
| 13.1.3(Armouring: Direction of Lay ) |
- |
500 |
|
- |
| 13.2(Type of armour ) |
- |
500 |
|
- |
| 13.3(Armouring : Dimensions -Wire Diameter) |
- |
500 |
|
- |
| 13.3(Armouring : Dimensions -Formed wire ) |
- |
500 |
|
- |
| 13.5(Armouring : Resistance Test) |
- |
1000 |
|
- |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
1000 |
|
- |
| 13.6 b)(ARMOURING: Elongation ) |
- |
1000 |
|
- |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
1000 |
|
- |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
1000 |
|
- |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
1000 |
|
- |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
1000 |
|
- |
| 13.6 g)(ARMOURING: Resistivity) |
- |
1000 |
|
- |
| 14.1(Outer Sheath : Application) |
- |
1000 |
|
- |
| 14.2(Colour of outer sheath) |
- |
1000 |
|
- |
| 14.3(Thickness of outer sheath - AVERAGE) |
- |
1000 |
|
- |
| 15.1 a) i)(Annealing Test ( For copper wire ) ) |
- |
1000 |
|
- |
| 15.1 a) ii)(Tensile test (for aluminium) - Before stranding ) |
- |
1000 |
|
- |
| 15.1 a) ii)(Tensile test (for aluminium) - After stranding ) |
- |
1000 |
|
- |
| 15.1 a) iii)(Wrapping test (for aluminium)) |
- |
500 |
|
- |
| 15.1 a) iv)(Resistance test - Main conductor) |
- |
1000 |
|
- |
| 15.1 a) iv)(Resistance test - Neutral conductor) |
- |
1000 |
|
- |
| 15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
1000 |
|
- |
| 15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
1000 |
|
- |
| 15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
1000 |
|
- |
| 15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
1000 |
|
- |
| 15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
1000 |
|
- |
| 15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
1000 |
|
- |
| 15.1 d) iv) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
1000 |
|
- |
| 15.1 d) v) (Insulation: Waterabsorption(gravimetric)) |
- |
1000 |
|
- |
| 15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
1000 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
1000 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
1000 |
|
- |
| 15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
1000 |
|
- |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
1000 |
|
- |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
1000 |
|
- |
| 15.1 e) v) (Sheath : Hot deformation) |
- |
1000 |
|
- |
| 15.1 e) vi) (Sheath : Heat shock test) |
- |
1000 |
|
- |
| 15.1 e) vii) (Sheath : Thermalstability) |
- |
1000 |
|
- |
| 15.1 f)(INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
1000 |
|
- |
| 16.2(HIGH VOLTAGE TEST ) |
- |
1000 |
|
- |
| 16.3(FLAMMABILITY TEST : Period of Burning ) |
- |
500 |
|
- |
| 16.3(FLAMMABILITY TEST : Unaffected length ) |
- |
500 |
|
- |
| 16.9(Oxygen Index Test) |
- |
5000 |
|
- |
| 16.14(Temperature Index) |
- |
5000 |
|
- |
| 16.1(Flame Retardance Test on Single Cables) |
- |
5000 |
|
- |
| 16.11(Flame Retardance Test on Bunched Cables) |
- |
5000 |
|
- |
| 16.13(Test for Halogen Acid Gas Evolution) |
- |
5000 |
|
- |
| 17.1(Manufacturer'. identification) |
- |
500 |
|
- |
| 17.2(cable Indentification ) |
- |
500 |
|
- |
| 17.3(cable Code ) |
- |
500 |
|
- |
| 15.4 (a)(Cold bend) |
- |
500 |
|
- |
| 15.4 (b)(Cold impact) |
- |
500 |
|
- |
| Cl No. 16.15(Smoke density test) |
- |
5000 |
|
- |
|
28 Nov, 2028 |
- - |
| 12609 |
Bharat Test House Pvt Ltd 1474 Sonipat Haryana
| 9135626
| IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
28000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(CONDUCTOR: MATERIALS) |
- |
0 |
|
- |
| 4(INSULATION : MATERIALS) |
- |
0 |
|
- |
| 5.1(FILLER AND INNER SHEATH) |
- |
0 |
|
- |
| 5.2(FILLER AND INNER SHEATH) |
- |
0 |
|
- |
| 6(ARMOURING) |
- |
0 |
|
- |
| 7(OUTER SHEATH) |
- |
0 |
|
- |
| 8.1(CONDUCTOR: CONSTRUCTION) |
- |
0 |
|
- |
| 8.2(PROTECTIVE BARRIER) |
- |
0 |
|
- |
| 8.3(SIZE OF NEUTRAL CONDUCTOR) |
- |
0 |
|
- |
| 9.1(Insulation Applied by extrusicn) |
- |
0 |
|
- |
| 9.2(Thickness of Insulation - Average) |
- |
1000 |
|
- |
| 9.3(Thickness of Insulation - Minimum) |
- |
1000 |
|
- |
| 9.4(Application of Insulation) |
- |
0 |
|
- |
| 10.1(Core Identification) |
- |
0 |
|
- |
| 10.2(Core Identification- Neutral) |
- |
0 |
|
- |
| 10.3(Core Identification by number ) |
- |
0 |
|
- |
| 10.4(Core Identification by number - Neutral ) |
- |
0 |
|
- |
| 11(LAVING UP OF CORES) |
- |
0 |
|
- |
| 12.1 & 12.2(Inner sheath : Application) |
- |
0 |
|
- |
| 12.3(Thickness of Inner Sheath) |
- |
1000 |
|
- |
| 13.1(Armouring: Application) |
- |
0 |
|
- |
| 13.1.2(Armouring: Coverage ) |
- |
0 |
|
- |
| 13.1.3(Armouring: Direction of Lay ) |
- |
0 |
|
- |
| 13.2(Type of armour ) |
- |
0 |
|
- |
| 13.3(Armouring : Dimensions -Wire Diameter) |
- |
1000 |
|
- |
| 13.3(Armouring : Dimensions -Formed wire ) |
- |
1000 |
|
- |
| 13.4(Armour: Joint) |
- |
0 |
|
- |
| 13.5(Armouring : Resistance Test) |
- |
800 |
|
- |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
1000 |
|
- |
| 13.6 b)(ARMOURING: Elongation ) |
- |
1000 |
|
- |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
750 |
|
- |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
750 |
|
- |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
750 |
|
- |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
750 |
|
- |
| 13.6 g)(ARMOURING: Resistivity) |
- |
800 |
|
- |
| 14.1(Outer Sheath : Application) |
- |
0 |
|
- |
| 14.2(Colour of outer sheath) |
- |
0 |
|
- |
| 14.3(Thickness of outer sheath - AVERAGE) |
- |
1000 |
|
- |
| 14.3(Thickness of outer sheath - minimum) |
- |
1000 |
|
- |
| 15.1 a) i)(Annealing Test ( For copper wire ) ) |
- |
1000 |
|
- |
| 15.1 a) ii)(Tensile test (for aluminium) - Before stranding ) |
- |
1000 |
|
- |
| 15.1 a) ii)(Tensile test (for aluminium) - After stranding ) |
- |
1200 |
|
- |
| 15.1 a) iii)(Wrapping test (for aluminium)) |
- |
1000 |
|
- |
| 15.1 a) iv)(Resistance test - Main conductor) |
- |
1000 |
|
- |
| 15.1 a) iv)(Resistance test - Neutral conductor) |
- |
1000 |
|
- |
| 15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
1000 |
|
- |
| 15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
1000 |
|
- |
| 15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
1000 |
|
- |
| 15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
1000 |
|
- |
| 15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
800 |
|
- |
| 15.1 d) iii) (Phyaical tests for insulation : Permanent set ) |
- |
800 |
|
- |
| 15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
800 |
|
- |
| 15.1 d) iv) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
800 |
|
- |
| 15.1 d) v) (Insulation: Waterabsorption(gravimetric)) |
- |
800 |
|
- |
| 15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
1000 |
|
- |
| 15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
1000 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
1200 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
1200 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
1200 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
1200 |
|
- |
| 15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
800 |
|
- |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
100 |
|
- |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
1000 |
|
- |
| 15.1 e) v) (Sheath : Hot deformation) |
- |
1100 |
|
- |
| 15.1 e) vi) (Sheath : Heat shock test) |
- |
800 |
|
- |
| 15.1 e) vii) (Sheath : Thermalstability) |
- |
800 |
|
- |
| 15.1 f)(INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
800 |
|
- |
| 16.2(HIGH VOLTAGE TEST ) |
- |
1500 |
|
- |
| 16.3(FLAMMABILITY TEST : Period of Burning ) |
- |
1600 |
|
- |
| 16.3(FLAMMABILITY TEST : Unaffected length ) |
- |
1600 |
|
- |
| 16.9(Oxygen Index Test) |
- |
1100 |
|
- |
| 16.1(Flame Retardance Test on Single Cables) |
- |
1250 |
|
- |
| 16.11(Flame Retardance Test on Bunched Cables) |
- |
1250 |
|
- |
| 16.13(Test for Halogen Acid Gas Evolution) |
- |
1100 |
|
- |
| 16.14(Temperature Index) |
- |
1100 |
|
- |
| 17.1(Manufacturer'. identification) |
- |
0 |
|
- |
| 17.2(cable Indentification ) |
- |
0 |
|
- |
| 17.3(cable Code ) |
- |
0 |
|
- |
|
19 Mar, 2026 |
- - |
| 12610 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 8069 (1989) |
High density polyethylene (HDPE) woven sacks for packing pesticides – Specification (second revision) |
- |
- View breakup
Rs.3088/-
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
31 Dec, 2026 |
- Included w.e.f. 29.06.2017. |
| 12611 |
URS PRODUCTS AND TESTING PVT LTD (F3), NOIDA
| 8136826
| IS 366 (1991) |
Electric iron - Specification (Fourth Revision) |
- |
15000 View breakup
Rs. 15000/-
[15% discount to BIS]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.0(Measurement of Heating up time) |
- |
2000 |
|
15% discount to BIS |
| 11.0(Measurement of sole plate temperature) |
- |
2000 |
|
15% discount to BIS |
| 12.0(Measurement of Tempearture Distribution) |
- |
2000 |
|
15% discount to BIS |
| 13.0(Measurement of Initial overswing temperature and Heating up excess temperature) |
- |
500 |
|
15% discount to BIS |
| 13.0(Measurement of Initial overswing temperature and Heating up excess temperature) |
- |
500 |
|
15% discount to BIS |
| 14.0(Measurement of Cyclic fluctuation of temperature of hottest point ) |
- |
1000 |
|
15% discount to BIS |
| 15(MEASUREMENT OF TEMPERATURE DROP UNDER LOAD) |
- |
1000 |
|
15% discount to BIS |
| 16.0(Measurement of Thermostatic staibility) |
- |
500 |
|
15% discount to BIS |
| 16.0(Measurement of Thermostatic staibility) |
- |
500 |
|
15% discount to BIS |
| 16.0(Measurement of Thermostatic staibility) |
- |
500 |
|
15% discount to BIS |
| 16.0(Measurement of Thermostatic staibility) |
- |
500 |
|
15% discount to BIS |
| 16.0(Measurement of Thermostatic staibility) |
- |
500 |
|
15% discount to BIS |
| 16.0(Measurement of Thermostatic staibility) |
- |
500 |
|
15% discount to BIS |
| 17(Measurement of Thermostatic staibility) |
- |
0 |
|
15% discount to BIS |
| 7.0(Classification (as per Cl.6 of IS 302-2-3 and Cl.6.1 of IS 302-1)) |
- |
250 |
|
15% discount to BIS |
| 7.0(Classification (as per Cl.6 of IS 302-2-3 and Cl.6.2 of IS 302-1)) |
- |
250 |
|
15% discount to BIS |
| 9.0(Protection against access to live parts (as per Cl. 8 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
15% discount to BIS |
| 9.0(Power input and current (as per Cl. 10 of IS 302-2-3 and IS 302-1)) |
- |
1000 |
|
15% discount to BIS |
| 9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
2500 |
|
15% discount to BIS |
| 9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
2500 |
|
15% discount to BIS |
| 9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
2500 |
|
15% discount to BIS |
| 9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
2500 |
|
15% discount to BIS |
| 9.0(Leakage current and Electric Strength at Operating Temperature (as per Cl. 13 of IS 302-2-3 and IS 302-1)) |
- |
250 |
|
15% discount to BIS |
| 9.0(Leakage current and Electric Strength at Operating Temperature (as per Cl. 13 of IS 302-2-3 and IS 302-1)) |
- |
250 |
|
15% discount to BIS |
| 9.0(Transient Overvoltage (as per of Cl. 14 of IS 302-2-3 and Table 6 of IS 302-1)) |
- |
500 |
|
15% discount to BIS |
| 9.0(Moisture Resistance (as per of Cl.15 of IS 302-2-3 and IS 302-1)) |
- |
750 |
|
15% discount to BIS |
| 9.0(Moisture Resistance (as per of Cl.15 of IS 302-2-3 and IS 302-1)) |
- |
750 |
|
15% discount to BIS |
| 9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Staibilty and mechanical hazards (as per of Cl.20 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
15% discount to BIS |
| 9.0(Mechanical strength (as per of Cl.21 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
15% discount to BIS |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
75 |
|
15% discount to BIS |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
75 |
|
15% discount to BIS |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
75 |
|
15% discount to BIS |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
75 |
|
15% discount to BIS |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
75 |
|
15% discount to BIS |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
75 |
|
15% discount to BIS |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
75 |
|
15% discount to BIS |
| 9.0(Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Components (as per of Cl.24 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
15% discount to BIS |
| 9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Screw and connections (as per of Cl.28 of IS 302-2-3 and IS 302-1)) |
- |
250 |
|
15% discount to BIS |
| 9.0(Screw and connections (as per of Cl.28 of IS 302-2-3 and IS 302-1)) |
- |
250 |
|
15% discount to BIS |
| 9.0(Clearances, creepage distances and solid insulation (as per of Cl.29 of IS 302-2-3 and IS 302-1)) |
- |
250 |
|
15% discount to BIS |
| 9.0(Clearances, creepage distances and solid insulation (as per of Cl.29 of IS 302-2-3 and IS 302-1)) |
- |
250 |
|
15% discount to BIS |
| 9.0(Resistance to Heat and Fire (as per of Cl.30 of IS 302-2-3 and IS 302-1)) |
- |
1000 |
|
15% discount to BIS |
| 9.0(Resistance to Rusting (as per of Cl.31 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
15% discount to BIS |
| 10.0(Measurement of Heating up time) |
- |
- |
|
- |
| 11.0(Measurement of sole plate temperature) |
- |
- |
|
- |
| 11.0(Measurement of sole plate temperature) |
- |
- |
|
- |
| 11.0(Measurement of sole plate temperature) |
- |
- |
|
- |
| 13.0(Measurement of Initial overswing temperature and Heating up excess temperature) |
- |
- |
|
- |
|
31 Dec, 2026 |
- - |
| 12612 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 13217 (1991) |
Thermoplastics fumigation covers |
- |
- View breakup
Rs.30550/-
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
31 Dec, 2026 |
- Included w.e.f. 29.06.2017. |
| 12613 |
National Test House (NR) - NTH, Ghaziabad
| 8101304
| IS 8978 (1992) |
Specification for electric instantaneous water heaters (Second Revision) |
` |
- View breakup
For BIS samples: BIS approved Testng charges. For Others: Rs.15000 (Inclusive of safety testing charges as per IS 302-2-35 @ Rs.5000/-)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
26 Oct, 2025 |
- - |
| 12614 |
MSME TESTING CENTRE, CHENNAI
| 6106704
| IS 398 : Part 4 (1994) |
Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
- |
3150 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1 Table-1(Dimensional measurement of wires) |
- |
630 |
|
for 7 stands |
| 12.2 Table 1(Breaking Load Test- Before Stranding) |
- |
1080 |
|
for 7 stands |
| 12.2 Table 1(Breaking Load Test- After Stranding) |
- |
1080 |
|
for 7 stands |
| 12.3 Table 1(Elongation Test- After Stranding) |
- |
450 |
|
for 7 stands |
| 12.3 Table 1(Elongation Test- Before Stranding) |
- |
450 |
|
for 7 stands |
| 12.4 Table 1(Resistance of Aluminium wire) |
- |
630 |
|
for 7 stands |
| 9.2 Table 3(Lay Ratio of stranded conductors) |
- |
360 |
|
for 7 stands |
|
31 Dec, 2026 |
- - |
| 12615 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 5378 (1994) |
Polyethylene cane - Specification (First Revision) |
- |
- View breakup
Rs.3225/-,
Rs.1988/- For Material
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
31 Dec, 2026 |
- Included on 29-05-2015 |
| 12616 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 6192 (1994) |
Textiles – Monoaxially oriented high density polyethylene tapes – Specification (second revision) |
- |
4600 View breakup
Rs.3450/-
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(MATERIAL(Refer IS 7328 :1974)) |
- |
500 |
|
Nil |
| 5.1(Linear density (For test method Refer IS 6193:1971 and IS 7703 Part 1)) |
- |
500 |
|
Nil |
| 5.2(Tenacity (For test method Refer IS 6193:1971)) |
- |
550 |
|
Nil |
| 5.3(Elongation (For test method Refer IS 6193:1971)) |
- |
550 |
|
Nil |
| 5.4(Finished width (For test method Refer IS 6193:1971)) |
- |
250 |
|
Nil |
| 5.5(Thickness (For test method Refer IS 6193:1971)) |
- |
200 |
|
Nil |
| 5.6(Heat Shrinkage at 60 degree C(For test method Refer IS 6193:1971)
) |
- |
850 |
|
NIl |
| 5.6(Heat Shrinkage at 95 degree C(For test method Refer IS 6193:1971)
) |
- |
850 |
|
Nil |
| 5.7( pigmented tapes) |
- |
0 |
|
Nil |
| 5.7( pigmented tapes(Refer IS 2454)) |
- |
850 |
|
Nil |
|
31 Dec, 2026 |
- - |
| 12617 |
CIPET, Hyderabad
| 6111634
| IS 10840 (1994) |
Blow moulded hdpe containers for packing of vanaspati - Specification (Second Revision) |
- |
- View breakup
Rs.4725/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
23 Feb, 2027 |
- - |
| 12618 |
CIPET, Hyderabad
| 6111634
| IS 12709 (1994) |
Glass - Fibre reinforced plastic (Grp) pipes joints and fittings for use for potable water supply - Specification (First Revision) |
- |
- View breakup
Rs.44000/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
23 Feb, 2027 |
- - |
| 12619 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 14182 (1994) |
Solvent cement for use with unplasticized polyvinyl chloride plastic pipe and fittings - Specifications |
- |
8600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 - Table 1 - v-a(Chemical Resistance - Change in mass, increase) |
- |
0 |
|
- |
| 4.1 - Table 1 - v-a(Chemical Resistance - Change in mass, Decrease) |
- |
0 |
|
- |
| 4.1 - Table 1 - v-b(Chemical Resistance - Change in flexural yield strength, Increase) |
- |
0 |
|
- |
| 4.1 - Table 1 - v-b(Chemical Resistance - Change in flexural yield strength, Decrease) |
- |
0 |
|
- |
| 4.2(Shall be thixotropic and consist substantially of solvents that will swell plastisized PVC polymers and stabilizers) |
- |
0 |
|
- |
| 4.3(Shall be capable of application by brush and shall contain no lumps or foreign matter or macroscopic undissolved particles that will adversely affect the ultimate joint strength or chemical resistance of the material ) |
- |
0 |
|
- |
| 4.4(Shall not show gelation and no evidence of stratification or separation that cannot be removed by stirring) |
- |
0 |
|
- |
| 4.5(When used under the conditions for which they are designed, non metallic materials in contact with or likely to come in contact with potable water shall not constitute a toxic hazard , shall not support microbial growth and shall not give rise to unpleasant taste or odour, cloudiness or discolouration of the water) |
- |
0 |
|
- |
| 4.6(Solvents systems consisting of blends of tetrahydrofuran and cyclohexanone have been found to be acceptable) |
- |
0 |
|
- |
| 4.7(Vinyl Chloride Polymer content - Annex A) |
- |
1100 |
|
- |
| 4.8(Dissolution - Capable of dissolving an additional unplastisized PVC granular, powder compound or resin) |
- |
400 |
|
- |
| 4.5(REQUIREMENTS) |
- |
300 |
|
VISUAL APPEARANCE |
| 4.9 and 6.1(Viscosity) |
- |
0 |
|
Test charges has already been taken in cl. no. 4.9 and 6.1. |
| 4.7 and 6.1(REQUIREMENTS - Vinyl Chloride Polymer Content) |
- |
0 |
|
Test charges has already been taken in cl. no. 4.7 |
| 4.9 and 6.1(Viscosity - Regular) |
- |
0 |
|
Test charges has already been taken in cl. no. 4.9 and 6.1. |
| 4.9 and 6.1(Viscosity - Medium) |
- |
0 |
|
Test charges has already been taken in cl. no. 4.9 and 6.1. |
| 4.9 and 6.1(Viscosity - Heavy ) |
- |
1100 |
|
- |
| 4.10 and 6.1(Lap Shear Strength - After 2 h curing time) |
- |
1100 |
|
- |
| 4.10 and 6.1(Lap Shear Strength - After 10 h curing time) |
- |
1100 |
|
- |
| 4.10 and 6.1(Lap Shear Strength - After 72 h curing time) |
- |
1600 |
|
- |
| 4.11 and 6.1(Hydrostatic Burst Strength - After 2 h curing time) |
- |
850 |
|
- |
|
31 Dec, 2026 |
- - |
| 12620 |
NATIONAL TEST HOUSE (SOUTHERN REGION) - NTH, CHENNAI
| 6122704
| IS 8783 : Part 4 : Sec 1 (1995) |
Winding wires for submersible motors - Specification: Part 4 specification for indmdual wires: Sec 1 HR PVC insulated wires (First Revision) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.3.1 (Conductor) |
- |
500 |
|
- |
| Cl.4(Material) |
- |
500 |
|
- |
| Cl.5.1.1 (Dimensions) |
- |
500 |
|
- |
| Cl 6(Resistance Test) |
- |
1000 |
|
- |
| Cl 4.1.2 (Visual examination) |
- |
500 |
|
- |
| Cl. 4 Table 1of IS: 8783 (part 2) (Volume resistivity) |
- |
1000 |
|
- |
| Cl. 4 Table 1of IS: 8783 (part 2) (Volume resistivity) |
- |
1000 |
|
- |
| Cl. 4 Table 1of IS: 8783 (part 2) (Tensile strength ) |
- |
1000 |
|
- |
| Cl. 4 Table 1of IS: 8783 (part 2) (Elongation) |
- |
1000 |
|
- |
| Cl. 4 Table 1of IS: 8783 (part 2) (Tensile Strength) |
- |
1000 |
|
- |
| Cl. 4 Table 1of IS: 8783 (part 2) (Elongation at Break ) |
- |
1000 |
|
- |
| Cl. 4 Table 1of IS: 8783 (part 2) (Variation) |
- |
1000 |
|
- |
| Cl. 4 Table 1of IS: 8783 (part 2) (Variation) |
- |
1000 |
|
- |
| Cl. 4 Table 1of IS: 8783 (part 2) (Shrinkage test ) |
- |
1000 |
|
- |
| Cl. 4 Table 1of IS: 8783 (part 2) (Water absorption (Gravimetric) ) |
- |
1000 |
|
- |
| Cl. 4 Table 1of IS: 8783 (part 2) (Hot deformation Test ) |
- |
1000 |
|
- |
| Cl. 4 Table 1of IS: 8783 (part 2) (Heat shock Test ) |
- |
1000 |
|
- |
| Cl.4.1(Insulation ) |
- |
1000 |
|
- |
| Cl.4.2(Application) |
- |
1000 |
|
- |
| Cl.4.3(Colour) |
- |
500 |
|
- |
| Cl.4.4(Overall Diameter) |
- |
500 |
|
- |
| Cl.4.5(Finish) |
- |
500 |
|
- |
| Cl.4.6(High Voltage Test Water Immersion ) |
- |
1000 |
|
- |
|
28 Nov, 2028 |
- - |
| 12621 |
NATIONAL TEST HOUSE (SOUTHERN REGION) - NTH, CHENNAI
| 6122704
| IS 8783 : Part 4 : Sec 3 (1995) |
Winding wires for submersible motors - Specification: Part 4 specification for individual wires: Sec 3 polyester and polypropylene insulated winding wires (First Revision) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
100 |
|
- |
| 6.1(The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
100 |
|
- |
| 6.1(a) Reference to this Indian Standard;) |
- |
100 |
|
- |
| 6.1(b) Manufacturer's name,brand name or trade-mark;) |
- |
100 |
|
- |
| 6.1(c) Size of conductor / maximum overall diameter,) |
- |
100 |
|
- |
| 6.1(d) Length of conductor on spool / reel /coil;) |
- |
100 |
|
- |
| 6.1(e) Number of lengths onspool / reel / coil (if more than one);) |
- |
100 |
|
- |
| 6.1(f) Country of Manufacturer) |
- |
100 |
|
- |
| 6.1(g) Year of Manufacture.) |
- |
100 |
|
- |
| 6.2(BIS Certification Mark) |
- |
100 |
|
- |
| 4(i) Material) |
- |
500 |
|
- |
| 5(ii) Diameter [mm] Seperate wire:) |
- |
500 |
|
- |
| 5(ii) Diameter [mm] Wire taken from cable:) |
- |
500 |
|
- |
| 5(iii) Annealing test [Percentage] on Seperate wire:) |
- |
500 |
|
- |
| 5(iii) Annealing test [Percentage] on Wire taken from cable:) |
- |
500 |
|
- |
| 5(d) Resistance test [Ohm/km corrected to 20°c) |
- |
500 |
|
- |
| 4.1, table 1 & 2(a) Thickness of Polyster (mm)) |
- |
500 |
|
- |
| 4.1, table 1 & 3(b) Thickness of Polypropylene (mm)) |
- |
500 |
|
- |
| 4.1, table 1 & 4(c) Total thickness of Insulation(mm)) |
- |
500 |
|
- |
| 4.2(Application of insulation) |
- |
500 |
|
- |
| 4.3(Colour of Insuation) |
- |
500 |
|
- |
| 4.4(Overall diameter (mm)) |
- |
500 |
|
- |
| 4(Before ageing Tensile strength [N/mm²]) |
- |
500 |
|
- |
| 4(Before ageing Elongation at break [Percentage]) |
- |
500 |
|
- |
| 4(After ageing Tensile strength [N/mm²]) |
- |
500 |
|
- |
| 4(Variation on tensile strangth [Percentage]) |
- |
500 |
|
- |
| 4(After ageing Elongation at break [Percentage]) |
- |
500 |
|
- |
| 4(Variation on elongation at break [Percentage]) |
- |
500 |
|
- |
| 4(High Voltage test [Water Immersion test] 3 KV for 1 Minute) |
- |
1000 |
|
- |
| Clause No. 3(Insulation Resistance (Volume Resistivity at 27º C )) |
- |
1000 |
|
- |
| Clause No. 3(Insulation Resistance (Volume Resistivity at test temperature 90 º C )) |
- |
1000 |
|
- |
| Clause No. 3(Heat Shock) |
- |
1000 |
|
- |
| Clause No. 3(Shrinkage) |
- |
1000 |
|
- |
| Clause No. 3(Hot Deformation) |
- |
1000 |
|
- |
| Clause No. 3(Water absorption) |
- |
1000 |
|
- |
|
28 Nov, 2028 |
- - |
| 12622 |
Bharat Test House Pvt Ltd 1474 Sonipat Haryana
| 9135626
| IS 8783 : Part 4 : Sec 3 (1995) |
Winding wires for submersible motors - Specification: Part 4 specification for individual wires: Sec 3 polyester and polypropylene insulated winding wires (First Revision) |
Winding Wires for Submersible Motors |
9500 View breakup
(5% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
200 |
|
- |
| 6.1(The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
200 |
|
- |
| 6.1(a) Reference to this Indian Standard;) |
- |
200 |
|
- |
| 6.1(b) Manufacturer's name,brand name or trade-mark;) |
- |
200 |
|
- |
| 6.1(c) Size of conductor / maximum overall diameter,) |
- |
200 |
|
- |
| 6.1(e) Number of lengths onspool / reel / coil (if more than one);) |
- |
200 |
|
- |
| 6.1(f) Country of Manufacturer) |
- |
200 |
|
- |
| 6.1(g) Year of Manufacture.) |
- |
200 |
|
- |
| 4(i) Material) |
- |
750 |
|
- |
| 5(ii) Diameter [mm] Seperate wire:) |
- |
750 |
|
- |
| 5(ii) Diameter [mm] Wire taken from cable:) |
- |
750 |
|
- |
| 5(iii) Annealing test [Percentage] on Seperate wire:) |
- |
750 |
|
- |
| 5(iii) Annealing test [Percentage] on Wire taken from cable:) |
- |
750 |
|
- |
| 5(d) Resistance test [Ohm/km corrected to 20°c) |
- |
750 |
|
- |
| 4.1, table 1 & 2(a) Thickness of Polyster (mm)) |
- |
750 |
|
- |
| 4.1, table 1 & 3(b) Thickness of Polypropylene (mm)) |
- |
750 |
|
- |
| 4.1, table 1 & 4(c) Total thickness of Insulation(mm)) |
- |
750 |
|
- |
| 4.2(Application of insulation) |
- |
750 |
|
- |
| 4.3(Colour of Insuation) |
- |
750 |
|
- |
| 4.4(Overall diameter (mm)) |
- |
750 |
|
- |
| 4(Before ageing Tensile strength [N/mm²]) |
- |
750 |
|
- |
| 4(Before ageing Elongation at break [Percentage]) |
- |
750 |
|
- |
| 4(After ageing Tensile strength [N/mm²]) |
- |
750 |
|
- |
| 4(Variation on tensile strangth [Percentage]) |
- |
750 |
|
- |
| 4(After ageing Elongation at break [Percentage]) |
- |
750 |
|
- |
| 4(Variation on elongation at break [Percentage]) |
- |
750 |
|
- |
| 4(Shrinkage test [Percentage]) |
- |
750 |
|
- |
| 4(After Shrinkage Cracks found.) |
- |
750 |
|
- |
| 4.5(High Voltage test [Water Immersion test] 3 KV for 1 Minute) |
- |
750 |
|
- |
| 4.1(Insulation Resistance test [ohm-cm] At 27 ºC) |
- |
750 |
|
- |
| 4.1([Insulation Resistance test [ohm-cm] At 90 ºC) |
- |
750 |
|
- |
| 5(The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
200 |
|
- |
| 6(The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
200 |
|
- |
| 6(a) Reference to this Indian Standard;) |
- |
200 |
|
- |
| 6(b) Manufacturer's name,brand name or trade-mark;) |
- |
200 |
|
- |
| 6(c) Size of conductor / maximum overall diameter,) |
- |
200 |
|
- |
| 6(d) Length of conductor on spool / reel /coil;) |
- |
200 |
|
- |
| 6(e) Number of lengths onspool / reel / coil (if more than one);) |
- |
200 |
|
- |
| 6(f) Country of Manufacturer Marking) |
- |
200 |
|
- |
| 6(g) Year of Manufacture.) |
- |
200 |
|
- |
| 6.2(BIS Certification Mark) |
- |
200 |
|
- |
| 4(i) Material) |
- |
750 |
|
- |
| 4(ii) Diameter [mm] Seperate wire:) |
- |
750 |
|
- |
| 4(ii) Diameter [mm] Wire taken from cable) |
- |
750 |
|
- |
| 4(iii) Annealing test [Percentage] on Seperate wire:) |
- |
750 |
|
- |
| 4([iii) Annealing test [Percentage] on Wire taken from cable:) |
- |
750 |
|
- |
| 4(d) Resistance test [Ohm/km corrected to 20°c]) |
- |
750 |
|
- |
| 4(a) Thickness of Polyster (mm)) |
- |
750 |
|
- |
| 4(b) Thickness of Polypropylene (mm)) |
- |
750 |
|
- |
| 4(c) Total thickness of Insulation(mm)) |
- |
750 |
|
- |
| 4(Application of insulation) |
- |
750 |
|
- |
| 4(Colour of Insuation) |
- |
750 |
|
- |
| 4(Overall diameter (mm)) |
- |
750 |
|
- |
| 4(Before ageing Tensile strength [N/mm²]) |
- |
750 |
|
- |
| 4(Before ageing Elongation at break [Percentage]) |
- |
750 |
|
- |
| 4(After ageing Tensile strength [N/mm²]) |
- |
750 |
|
- |
| 4(Variation on tensile strangth [Percentage]) |
- |
750 |
|
- |
| 4(After ageing Elongation at break [Percentage]) |
- |
750 |
|
- |
| 4(Variation on elongation at break [Percentage]) |
- |
750 |
|
- |
| 4(Shrinkage test [Percentage]) |
- |
750 |
|
- |
| 4(After Shrinkage Cracks found.) |
- |
750 |
|
- |
| 4(Water absorption test [Gravimetric] [mg/cm²]) |
- |
750 |
|
- |
| 4(Hot Deformation test [depth of indentation) [Percentage]) |
- |
750 |
|
- |
| 4(High Voltage test [Water Immersion test] 3 KV for 1 Minute) |
- |
750 |
|
- |
| 4(Insulation Resistance test [ohm-cm] At 27 ºC) |
- |
750 |
|
- |
| 4(Insulation Resistance test [ohm-cm] At 90 ºC) |
- |
750 |
|
- |
| 5.1(The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
200 |
|
5% discount for BIS |
| 6.1(The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
200 |
|
5% discount for BIS |
| 6.1(a) Reference to this Indian Standard;) |
- |
200 |
|
5% discount for BIS |
| 6.1(b) Manufacturer's name,brand name or trade-mark;) |
- |
200 |
|
5% discount for BIS |
| 6.1(c) Size of conductor / maximum overall diameter,) |
- |
200 |
|
5% discount for BIS |
| 6.1(e) Number of lengths onspool / reel / coil (if more than one);) |
- |
200 |
|
5% discount for BIS |
| 6.1(f) Country of Manufacturer) |
- |
200 |
|
5% discount for BIS |
| 6.1(g) Year of Manufacture.) |
- |
200 |
|
5% discount for BIS |
| 4(i) Material) |
- |
750 |
|
5% discount for BIS |
| 5(ii) Diameter [mm] Seperate wire:) |
- |
750 |
|
5% discount for BIS |
| 5(ii) Diameter [mm] Wire taken from cable:) |
- |
750 |
|
5% discount for BIS |
| 5(iii) Annealing test [Percentage] on Seperate wire:) |
- |
750 |
|
5% discount for BIS |
| 5(iii) Annealing test [Percentage] on Wire taken from cable:) |
- |
750 |
|
5% discount for BIS |
| 5(d) Resistance test [Ohm/km corrected to 20°c) |
- |
750 |
|
5% discount for BIS |
| 4.1, table 1 & 2(a) Thickness of Polyster (mm)) |
- |
750 |
|
5% discount for BIS |
| 4.1, table 1 & 3(b) Thickness of Polypropylene (mm)) |
- |
750 |
|
5% discount for BIS |
| 4.1, table 1 & 4(c) Total thickness of Insulation(mm)) |
- |
750 |
|
5% discount for BIS |
| 4.2(Application of insulation) |
- |
750 |
|
5% discount for BIS |
| 4.3(Colour of Insuation) |
- |
750 |
|
5% discount for BIS |
| 4.4(Overall diameter (mm)) |
- |
750 |
|
5% discount for BIS |
| 4(Before ageing Tensile strength [N/mm²]) |
- |
750 |
|
5% discount for BIS |
| 4(Before ageing Elongation at break [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(After ageing Tensile strength [N/mm²]) |
- |
750 |
|
5% discount for BIS |
| 4(Variation on tensile strangth [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(After ageing Elongation at break [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(Variation on elongation at break [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(Shrinkage test [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(After Shrinkage Cracks found.) |
- |
750 |
|
5% discount for BIS |
| 4.5(High Voltage test [Water Immersion test] 3 KV for 1 Minute) |
- |
750 |
|
5% discount for BIS |
| 4.1(Insulation Resistance test [ohm-cm] At 27 ºC) |
- |
750 |
|
5% discount for BIS |
| 4.1([Insulation Resistance test [ohm-cm] At 90 ºC) |
- |
750 |
|
5% discount for BIS |
| 5(The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
200 |
|
5% discount for BIS |
| 6(The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
200 |
|
5% discount for BIS |
| 6(a) Reference to this Indian Standard;) |
- |
200 |
|
5% discount for BIS |
| 6(b) Manufacturer's name,brand name or trade-mark;) |
- |
200 |
|
5% discount for BIS |
| 6(c) Size of conductor / maximum overall diameter,) |
- |
200 |
|
5% discount for BIS |
| 6(d) Length of conductor on spool / reel /coil;) |
- |
200 |
|
5% discount for BIS |
| 6(e) Number of lengths onspool / reel / coil (if more than one);) |
- |
200 |
|
5% discount for BIS |
| 6(f) Country of Manufacturer Marking) |
- |
200 |
|
5% discount for BIS |
| 6(g) Year of Manufacture.) |
- |
200 |
|
5% discount for BIS |
| 6.2(BIS Certification Mark) |
- |
200 |
|
5% discount for BIS |
| 4(i) Material) |
- |
750 |
|
5% discount for BIS |
| 4(ii) Diameter [mm] Seperate wire:) |
- |
750 |
|
5% discount for BIS |
| 4(ii) Diameter [mm] Wire taken from cable) |
- |
750 |
|
5% discount for BIS |
| 4(iii) Annealing test [Percentage] on Seperate wire:) |
- |
750 |
|
5% discount for BIS |
| 4([iii) Annealing test [Percentage] on Wire taken from cable:) |
- |
750 |
|
5% discount for BIS |
| 4(d) Resistance test [Ohm/km corrected to 20°c]) |
- |
750 |
|
5% discount for BIS |
| 4(a) Thickness of Polyster (mm)) |
- |
750 |
|
5% discount for BIS |
| 4(b) Thickness of Polypropylene (mm)) |
- |
750 |
|
5% discount for BIS |
| 4(c) Total thickness of Insulation(mm)) |
- |
750 |
|
5% discount for BIS |
| 4(Application of insulation) |
- |
750 |
|
5% discount for BIS |
| 4(Colour of Insuation) |
- |
750 |
|
5% discount for BIS |
| 4(Overall diameter (mm)) |
- |
750 |
|
5% discount for BIS |
| 4(Before ageing Tensile strength [N/mm²]) |
- |
750 |
|
5% discount for BIS |
| 4(Before ageing Elongation at break [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(After ageing Tensile strength [N/mm²]) |
- |
750 |
|
5% discount for BIS |
| 4(Variation on tensile strangth [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(After ageing Elongation at break [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(Variation on elongation at break [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(Shrinkage test [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(After Shrinkage Cracks found.) |
- |
750 |
|
5% discount for BIS |
| 4(Water absorption test [Gravimetric] [mg/cm²]) |
- |
750 |
|
5% discount for BIS |
| 4(Hot Deformation test [depth of indentation) [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(High Voltage test [Water Immersion test] 3 KV for 1 Minute) |
- |
750 |
|
5% discount for BIS |
| 4(Insulation Resistance test [ohm-cm] At 27 ºC) |
- |
750 |
|
5% discount for BIS |
| 4(Insulation Resistance test [ohm-cm] At 90 ºC) |
- |
750 |
|
5% discount for BIS |
| 4.1(Heat Shock Test - No cracks found) |
- |
600 |
|
5% discount for BIS |
|
19 Mar, 2026 |
- Included w.e.f 13.05.2020 |
| 12623 |
DELHI TEST HOUSE, Azadhpur
| 8131406
| IS 14309 (1995) |
Blended edible vegetable oils specification |
- |
9500 View breakup
Rs.9500.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table-1(Moisture and volatile matter percent by mass, Max type1) |
- |
750 |
|
N.A. |
| Table-1(Acid value, mx type 1) |
- |
500 |
|
N.A. |
| Table-1(Unsaponifiable matter, percent by mass, MaX type1) |
- |
500 |
|
N.A. |
| Table-1(Flash point, Pen&y-Martens type1) |
- |
400 |
|
N.A. |
|
17 Jun, 2027 |
- - |
| 12624 |
National Test House (NR) - NTH, Ghaziabad
| 8101304
| IS 1328 (1996) |
Veneered Decorative Plywood -Specification |
BWR/MR/TYPE I/TYPE II |
5000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Grade - For BWR) |
- |
0 |
|
- |
| 4.1(Grade - For MR) |
- |
0 |
|
- |
| 4.2(Type - For Type 1) |
- |
0 |
|
- |
| 4.2(Type - For Type 2) |
- |
0 |
|
- |
| 7.1.1(Requirements - Open splits, checks or open joints - For Type 1 - Cl. 7.1.1) |
- |
250 |
|
- |
| 7.2.1(Requirements - Open splits, checks or open joints - For Type 2 - Cl. 7.2.1) |
- |
250 |
|
- |
| 7.1.2(Requirements - Other defects - For Type 1 - Cl. 7.1.2) |
- |
250 |
|
- |
| 7.2.2(Requirements - Other defects - For Type 2 - Cl. 7.2.2.) |
- |
250 |
|
- |
| 7.1.3(Requirements - Other Charcteristics and Manufacturing Defects - For Type 1 - Cl. 7.1.3) |
- |
250 |
|
- |
| 7.2.3(Requirements - Other Charcteristics and Manufacturing Defects - For Type 2 - Cl. 7.2.3) |
- |
250 |
|
- |
| 8(Dimensions & Tolerances - Length - Cl. 8) |
- |
250 |
|
- |
| 8(Dimensions & Tolerances - Width - Cl. 8) |
- |
250 |
|
- |
| 8(Dimensions & Tolerances - Thickness - Cl. 8) |
- |
250 |
|
- |
| 8(Dimensions & Tolerances - Edge Straightness - Annexure C) |
- |
250 |
|
- |
| 8(Dimensions & Tolerances - Squareness - Annexure C) |
- |
250 |
|
- |
| 9(Finish - Cl. 9.1, 8.3) |
- |
0 |
|
- |
| 9(Finish - Cl. 9.2, 8.3) |
- |
0 |
|
- |
| 11(Tests - Moisture Content - Part 1 of IS 1734) |
- |
1000 |
|
- |
| 11(Tests - Water Resistance Test - Cl. 11.1.2.1 [for MR Grade]) |
- |
2000 |
|
- |
| 11(Tests - Water Resistance Test - Cl. 11.1.2.2 [for BWR Grade]) |
- |
2000 |
|
- |
|
26 Oct, 2025 |
- - |
| 12625 |
National Test House (NR) - NTH, Ghaziabad
| 8101304
| IS 14333 (1996) |
High Density Polyethylene Pipe For Sewerage - |
- |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.2(Reversion) |
- |
1000 |
|
- |
| 8.1(Hydraulic characteristics) |
- |
5000 |
|
- |
| 8.3(Density) |
- |
1500 |
|
- |
| 8.4(Melt Flow Rate) |
- |
1000 |
|
- |
| Cl. 8.5, IS 2530-1963, Cl. 10(Cabon Black Content) |
- |
1000 |
|
- |
| 6(Dimensions of pipes) |
- |
500 |
|
- |
| 10(Marking) |
- |
500 |
|
- |
| 3(Designation) |
- |
500 |
|
- |
| 4(Colour) |
- |
500 |
|
- |
| Cl. 8.5, IS 2530-1963, Cl. 16(Carbon Black Dispersion) |
- |
500 |
|
- |
|
26 Oct, 2025 |
- - |
| 12626 |
National Test House (NR) - NTH, Ghaziabad
| 8101304
| IS 3854 (1997) |
Switches for domestic and similar purposes - Specification (Second Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8(Marking) |
- |
1000 |
|
- |
| 8.9(Marking) |
- |
500 |
|
- |
| 6(Rating) |
- |
500 |
|
- |
| 7(Classification) |
- |
500 |
|
- |
| 10(Protection against Electric Shock) |
- |
500 |
|
- |
| 11.1(Provision for earthing) |
- |
500 |
|
- |
| 12(Terminals) |
- |
500 |
|
- |
| 12.2.2(Connection of conductor) |
- |
500 |
|
- |
| 12.2.3(Mechanical strength of terminals) |
- |
500 |
|
- |
|
26 Oct, 2025 |
- - |
| 12627 |
NATIONAL TEST HOUSE (SOUTHERN REGION) - NTH, CHENNAI
| 6122704
| IS 3854 (1997) |
Switches for domestic and similar purposes - Specification (Second Revision) |
- |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Rating) |
- |
500 |
|
- |
| 6(Rating) |
- |
500 |
|
- |
| 7(Classification) |
- |
500 |
|
- |
| 7(Classification) |
- |
500 |
|
- |
| 7(Classification) |
- |
500 |
|
- |
| 8(Marking) |
- |
500 |
|
- |
| 8(Marking) |
- |
500 |
|
- |
| 8(Marking) |
- |
500 |
|
- |
| 8(Marking) |
- |
500 |
|
- |
| 8(Marking) |
- |
500 |
|
- |
| 10(Protection against Electric Shock) |
- |
1000 |
|
- |
| 11.1(Provision for earthing) |
- |
500 |
|
- |
| 12(Terminals) |
- |
500 |
|
- |
| 12.2.2(Connection of conductor) |
- |
500 |
|
- |
| 12.2.3(Mechanical strength of terminals) |
- |
500 |
|
- |
| 12.2.4(Resistance to corrosion) |
- |
1000 |
|
- |
| 12.2.5(Undue damage to conductor) |
- |
500 |
|
- |
| 12.2.7(Insertion of conductor) |
- |
500 |
|
- |
| 13.2(b) Construction of switch [Cl 13.2]) |
- |
500 |
|
- |
| 13.3(c) Covers,cover plates and actuating members [Cl 13.3]) |
- |
500 |
|
- |
| 14(Mechanism [Cl. 14]) |
- |
1000 |
|
- |
| 15.1(Resistance to Ageing, to Harmful Ingress of water and to Humidity [Cl. 15]: Resistance to Ageing, [Cl. 15.1]) |
- |
1000 |
|
- |
| 16.1(Insulation resistance [Cl. 16.1]) |
- |
1000 |
|
- |
| 16.2( Electric Strength [Cl. 16.2]) |
- |
1000 |
|
- |
| 17(Temperature- rise [Cl. 17]) |
- |
1500 |
|
- |
| 18(Marking and breaking Capacity[Cl. 18]) |
- |
1500 |
|
- |
| 18(Marking and breaking Capacity[Cl. 18]) |
- |
1500 |
|
- |
| 19(Normal Operation [Cl. 19] a) General & Operation) |
- |
1000 |
|
- |
| 20(Mechanical Strength Test [Cl. 20]) |
- |
1000 |
|
- |
| 21(Resistance to Heat [Cl.21]) |
- |
1500 |
|
- |
| 22(Screw, Current Carrying Part And Connection [Cl.22]) |
- |
1000 |
|
- |
| 23.2(Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
500 |
|
- |
| 23(Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
1000 |
|
- |
| 19.2(Normal Operation (For AX type Switches) [Cl. 19.2]) |
- |
1500 |
|
- |
| 24.1.1(Resistance to Abnormal Heat & Fire [Cl.24.1] [Glow Wire Test] [Cl.24.1.1]) |
- |
1000 |
|
- |
| 25(Resistance to Rusting) |
- |
1000 |
|
- |
|
28 Nov, 2028 |
- - |
| 12628 |
CIPET, Hyderabad
| 6111634
| IS 14482 (1997) |
Irrigation equipment - Polyethylene micro tubes for drip irrigation - Specification |
- |
- View breakup
Rs.4725/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
23 Feb, 2027 |
- Testing charges has been fixed for a period of two years w.e.f. 29.01.2019 i.e. up to 28.01.2021 |
| 12629 |
DELHI TEST HOUSE, Azadhpur
| 8131406
| IS 14542 (1998) |
Partly skimmed milk powder specification |
- |
4200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table 1(i)(Moisture Type I (IS 11623)) |
- |
500 |
|
- |
| Table 1(i)(Moisture Type II (IS 11623)) |
- |
500 |
|
- |
| Table 1(ii)(Total solids (milk solids and added salts) Type I (IS 11623)) |
- |
400 |
|
- |
| Table 1(ii)(Total solids (milk solids and added salts) Type II (IS 11623)) |
- |
400 |
|
- |
| Table 1(iii)(Milk fat, Type I (IS I1722)) |
- |
400 |
|
- |
| Table 1(iii)(Milk fat, Type II (IS I1722)) |
- |
400 |
|
- |
| Table 1(iv)(Insolubility index, a) Roller dried Type I (IS 12759)) |
- |
400 |
|
- |
| Table 1(iv)(Insolubility index, a) Roller dried Type II (IS 12759)) |
- |
400 |
|
- |
| Table 1(iv)(Insolubility index, b) Spray dried Type I (IS 12759)) |
- |
400 |
|
- |
| Table 1(iv)(Insolubility index, b) Spray dried Type II (IS 12759)) |
- |
400 |
|
- |
| Table 1(v)(Total ash Type I (Annex B of IS 14433 - Part 1)) |
- |
500 |
|
- |
| Table 1(v)(Total ash Type II (Annex B of IS 14433 - Part 1)) |
- |
500 |
|
- |
| Table 1(vi)(Titratable acidity (as lactic acid) Type I (IS 11766)) |
- |
400 |
|
- |
| Table 1(vi)(Titratable acidity (as lactic acid) Type II (IS 11766)) |
- |
400 |
|
- |
| Cl 6.4(Flavour and Taste (IS 10030)) |
- |
200 |
|
- |
| Cl 6.6.1(Bacterial Count (IS 5402)) |
- |
500 |
|
- |
| Cl 6.6.2(Coliform Count ((IS 5402)) |
- |
500 |
|
- |
|
17 Jun, 2027 |
- - |
| 12630 |
NATIONAL TEST HOUSE (SOUTHERN REGION) - NTH, CHENNAI
| 6122704
| IS 371 (1999) |
Ceiling roses - Specification (Third Revision) |
- |
5000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9(Marking) |
- |
100 |
|
- |
| 10.1(Dimentions) |
- |
100 |
|
- |
| 10.2(Dimentions) |
- |
100 |
|
- |
| 10.2(Dimentions) |
- |
100 |
|
- |
| 11.1(Accessibility of live parts ) |
- |
500 |
|
- |
| 11.2(Accessibility of live parts ) |
- |
100 |
|
- |
| 11.3(Accessibility of live parts ) |
- |
100 |
|
- |
| 11.4(Accessibility of live parts ) |
- |
100 |
|
- |
| 12.1(Provision for Earthing) |
- |
500 |
|
- |
| 12.2(Provision for Earthing) |
- |
100 |
|
- |
| 13.1(Terminals) |
- |
100 |
|
- |
| 13.2(Terminals) |
- |
100 |
|
- |
| 13.3(Terminals) |
- |
100 |
|
- |
| 13.4(Terminals) |
- |
100 |
|
- |
| 13.5(Terminals) |
- |
100 |
|
- |
| 13.6(Terminals) |
- |
100 |
|
- |
| 13.7(Terminals) |
- |
100 |
|
- |
| 13.8.1(Terminals) |
- |
100 |
|
- |
| 13.8.2(Terminals) |
- |
100 |
|
- |
| 13.8.3(Terminals) |
- |
100 |
|
- |
| 14.1(Construction) |
- |
500 |
|
- |
| 14.2(Construction) |
- |
100 |
|
- |
| 14.3(Construction) |
- |
100 |
|
- |
| 14.4(Construction) |
- |
100 |
|
- |
| 15.1(RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
1000 |
|
- |
| 15.2(RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
500 |
|
- |
| 15.3(RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
500 |
|
- |
| 15.4(RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
500 |
|
- |
| 15.5(RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
500 |
|
- |
| 15.6(RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
500 |
|
- |
| 15.7(RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
500 |
|
- |
| 16(Temperature Rise Test) |
- |
1000 |
|
- |
| 17(Temperature Rise Test) |
- |
1000 |
|
- |
| 18(Resistance to heat) |
- |
1000 |
|
- |
| 19(Resistance to abnormal heat fire and tracking) |
- |
1000 |
|
- |
| 19.3(Resistance to abnormal heat fire and tracking) |
- |
500 |
|
- |
| 20.1(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
500 |
|
- |
| 20.2(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
500 |
|
- |
| 20.3(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
500 |
|
- |
| 21.1(CREEPAGE DISTANCE AND CLEARANCES) |
- |
500 |
|
- |
| 22.1(Resistance to Excessive residual Stress and to Rusting ) |
- |
500 |
|
- |
| 22.1(Resistance to Excessive residual Stress and to Rusting ) |
- |
500 |
|
- |
|
28 Nov, 2028 |
- - |