| 12721 |
ABSOLUTE TESTING SERVICES, FARIDABAD
| 8174526
| IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
- |
23100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
3500 |
|
- |
| 7.0(Marking and instructions) |
- |
3500 |
|
- |
| 8.0(Protection against access to live part test) |
- |
3500 |
|
- |
| 10.0(Power Input and current test) |
- |
3500 |
|
- |
| 11.0(Heating test) |
- |
3500 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
3500 |
|
- |
| 14.0(Transient voltages) |
- |
3500 |
|
- |
| 15.0(Moisture Resistance) |
- |
3500 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
3500 |
|
- |
| 19.0(Abnormal Operations) |
- |
3500 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
3500 |
|
- |
| 21.0(Mechanical Strength) |
- |
3500 |
|
- |
| 22.0(Construction verification related tests) |
- |
3500 |
|
- |
| 23.0(Internal wiring) |
- |
3500 |
|
- |
| 24.0(Components) |
- |
3500 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
3500 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
3500 |
|
- |
| 27.0(Provision for Earthing) |
- |
3500 |
|
- |
| 28.0(Screws and connections) |
- |
3500 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
3500 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
3500 |
|
- |
| 31.0(Resistance to rusting) |
- |
3500 |
|
- |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
3500 |
|
- |
| 4(General Requirements) |
- |
3500 |
|
- |
| 5(General condition for the tests) |
- |
3500 |
|
- |
|
13 Nov, 2029 |
- Exclusion: Cl. 32.0 (Radiation, Toxicity and Similar hazards), Cl. 19.11.4.1 (Electrostatic discharges), Cl. 19.11.4.2 (Radiated fields), Cl. 19.11.4.3 (Fast transient bursts), Cl. 19.11.4.4 (Surge immunity test), CL. 19.11.4.5 (Immunity to conducted discharges), Cl. 19.11.4.6 (Class 3 Voltage dips and interruptions), Cl. 19.11.4.7 (Harmonics) |
| 12722 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 302 : Part 2 : Sec 206 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 206 electric coffee makers |
- |
26500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Rating) |
- |
2000 |
|
- |
| 6(Classification) |
- |
2000 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
2000 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
5000 |
|
- |
| 10(Input) |
- |
5000 |
|
- |
| 11(Temperature Rise/Heating) |
- |
5000 |
|
- |
| 12(Operation under overload conditions of appliances with heating elements) |
- |
5000 |
|
- |
| 13(Electrical insulation and Leakage Current at Operating Temperature) |
- |
5000 |
|
- |
| 14(Radio and television interference suppression/ Transient Overvoltages) |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 16(Insulation resistance and Electric Strength (After humidity treatment)) |
- |
5000 |
|
- |
| 17(Overload Protection) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
10000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal wiring) |
- |
5000 |
|
- |
| 24(Component) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 28(Screws & Connection) |
- |
5000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
5000 |
|
- |
| 30(Resistance to Heat, Fire and Tracking) |
- |
5000 |
|
- |
| 31(Resistance to Rusting) |
- |
5000 |
|
- |
| 32(Radiation hazards) |
- |
5000 |
|
- |
| 5(Rating) |
- |
2000 |
|
- |
| 6(Classification) |
- |
2000 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
2000 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
5000 |
|
- |
| 10(Input) |
- |
5000 |
|
- |
| 11(Temperature Rise/Heating) |
- |
5000 |
|
- |
| 12(Operation under overload conditions of appliances with heating elements) |
- |
5000 |
|
- |
| 13(Electrical insulation and Leakage Current at Operating Temperature) |
- |
5000 |
|
- |
| 14(Radio and television interference suppression/ Transient Overvoltages) |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 16(Insulation resistance and Electric Strength (After humidity treatment)) |
- |
5000 |
|
- |
| 17(Overload Protection) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
10000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal wiring) |
- |
5000 |
|
- |
| 24(Component) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 28(Screws & Connection) |
- |
5000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
5000 |
|
- |
| 30(Resistance to Heat, Fire and Tracking) |
- |
5000 |
|
- |
| 31(Resistance to Rusting) |
- |
5000 |
|
- |
| 32(Radiation hazards) |
- |
5000 |
|
- |
| 5(Rating) |
- |
2000 |
|
- |
| 6(Classification) |
- |
2000 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
2000 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
5000 |
|
- |
| 10(Input) |
- |
5000 |
|
- |
| 11(Temperature Rise/Heating) |
- |
5000 |
|
- |
| 12(Operation under overload conditions of appliances with heating elements) |
- |
5000 |
|
- |
| 13(Electrical insulation and Leakage Current at Operating Temperature) |
- |
5000 |
|
- |
| 14(Radio and television interference suppression/ Transient Overvoltages) |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 16(Insulation resistance and Electric Strength (After humidity treatment)) |
- |
5000 |
|
- |
| 17(Overload Protection) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
10000 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal wiring) |
- |
5000 |
|
- |
| 24(Component) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 28(Screws & Connection) |
- |
5000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
5000 |
|
- |
| 30(Resistance to Heat, Fire and Tracking) |
- |
5000 |
|
- |
| 31(Resistance to Rusting) |
- |
5000 |
|
- |
| 32(Radiation hazards) |
- |
5000 |
|
- |
| 5(Rating) |
- |
2000 |
|
- |
| 6(Classification) |
- |
2000 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
2000 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
5000 |
|
- |
| 10(Input) |
- |
5000 |
|
- |
| 11(Temperature Rise/Heating) |
- |
5000 |
|
- |
| 12(Operation under overload conditions of appliances with heating elements) |
- |
5000 |
|
- |
| 13(Electrical insulation and Leakage Current at Operating Temperature) |
- |
5000 |
|
- |
| 14(Radio and television interference suppression/ Transient Overvoltages) |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 16(Insulation resistance and Electric Strength (After humidity treatment)) |
- |
5000 |
|
- |
| 17(Overload Protection) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
10000 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal wiring) |
- |
5000 |
|
- |
| 24(Component) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 28(Screws & Connection) |
- |
5000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
5000 |
|
- |
| 30(Resistance to Heat, Fire and Tracking) |
- |
5000 |
|
- |
| 31(Resistance to Rusting) |
- |
5000 |
|
- |
| 32(Radiation hazards) |
- |
5000 |
|
- |
|
14 Nov, 2027 |
- Exclusion: 19.11.4.1 (Electrostatic discharges)
19.11.4.2 (Radiated fields)
19.11.4.3 (Fast transient bursts)
19.11.4.4 (Surge immunity test)
19.11.4.5 (Immunity to conducted discharges)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.7 (Harmonics) |
| 12723 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 302 : Part 2 : Sec 45 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 45 electric heating tools |
- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Rating) |
- |
2000 |
|
- |
| 6(Classification) |
- |
2000 |
|
- |
| 7(Marking) |
- |
2000 |
|
- |
| 8(Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
5000 |
|
- |
| 10("Power Input
& Current") |
- |
5000 |
|
- |
| 11(Temperature Rise/ Heating) |
- |
5000 |
|
- |
| 12(Operation Under Overload Condition) |
- |
5000 |
|
- |
| 13(Electric Insulation at Operating Temperature) |
- |
5000 |
|
- |
| 14("Radio and Television Interference Suppression / Transient Over Voltage
") |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 16(Insulation Resistance and Electric Strength/ Leakage Current and Electric Strength (After Humidity Treatment)) |
- |
5000 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal Wiring) |
- |
5000 |
|
- |
| 24(Components) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cords) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 28(Screws & Connections) |
- |
5000 |
|
- |
| 29(Creepage Distances & Clearances) |
- |
5000 |
|
- |
| 30(Resistance to Heat, Fire and Tracking) |
- |
5000 |
|
- |
| 31(Radiation hazards) |
- |
0 |
|
- |
| XXV of Table 101(Resistance to Rusting) |
- |
10000 |
|
- |
| 5(Rating) |
- |
2000 |
|
- |
| 6(Classification) |
- |
2000 |
|
- |
| 7(Marking) |
- |
2000 |
|
- |
| 8(Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
5000 |
|
- |
| 10("Power Input
& Current") |
- |
5000 |
|
- |
| 11(Temperature Rise/ Heating) |
- |
5000 |
|
- |
| 12(Operation Under Overload Condition) |
- |
5000 |
|
- |
| 13(Electric Insulation at Operating Temperature) |
- |
5000 |
|
- |
| 14("Radio and Television Interference Suppression / Transient Over Voltage
") |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 16(Insulation Resistance and Electric Strength/ Leakage Current and Electric Strength (After Humidity Treatment)) |
- |
5000 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal Wiring) |
- |
5000 |
|
- |
| 24(Components) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cords) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 28(Screws & Connections) |
- |
5000 |
|
- |
| 29(Creepage Distances & Clearances) |
- |
5000 |
|
- |
| 30(Resistance to Heat, Fire and Tracking) |
- |
5000 |
|
- |
| 31(Radiation hazards) |
- |
0 |
|
- |
| XXV of Table 101(Resistance to Rusting) |
- |
10000 |
|
- |
| 5(Rating) |
- |
2000 |
|
- |
| 6(Classification) |
- |
2000 |
|
- |
| 7(Marking) |
- |
2000 |
|
- |
| 8(Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
5000 |
|
- |
| 10("Power Input
& Current") |
- |
5000 |
|
- |
| 11(Temperature Rise/ Heating) |
- |
5000 |
|
- |
| 12(Operation Under Overload Condition) |
- |
5000 |
|
- |
| 13(Electric Insulation at Operating Temperature) |
- |
5000 |
|
- |
| 14("Radio and Television Interference Suppression / Transient Over Voltage
") |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 16(Insulation Resistance and Electric Strength/ Leakage Current and Electric Strength (After Humidity Treatment)) |
- |
5000 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal Wiring) |
- |
5000 |
|
- |
| 24(Components) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cords) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 28(Screws & Connections) |
- |
5000 |
|
- |
| 29(Creepage Distances & Clearances) |
- |
5000 |
|
- |
| 30(Resistance to Heat, Fire and Tracking) |
- |
5000 |
|
- |
| 31(Radiation hazards) |
- |
0 |
|
- |
| XXV of Table 101(Resistance to Rusting) |
- |
10000 |
|
- |
| 5(Rating) |
- |
2000 |
|
- |
| 6(Classification) |
- |
2000 |
|
- |
| 7(Marking) |
- |
2000 |
|
- |
| 8(Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
5000 |
|
- |
| 10("Power Input
& Current") |
- |
5000 |
|
- |
| 11(Temperature Rise/ Heating) |
- |
5000 |
|
- |
| 12(Operation Under Overload Condition) |
- |
5000 |
|
- |
| 13(Electric Insulation at Operating Temperature) |
- |
5000 |
|
- |
| 14("Radio and Television Interference Suppression / Transient Over Voltage
") |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 16(Insulation Resistance and Electric Strength/ Leakage Current and Electric Strength (After Humidity Treatment)) |
- |
5000 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal Wiring) |
- |
5000 |
|
- |
| 24(Components) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cords) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 28(Screws & Connections) |
- |
5000 |
|
- |
| 29(Creepage Distances & Clearances) |
- |
5000 |
|
- |
| 30(Resistance to Heat, Fire and Tracking) |
- |
5000 |
|
- |
| 31(Radiation hazards) |
- |
0 |
|
- |
| XXV of Table 101(Resistance to Rusting) |
- |
10000 |
|
- |
| 4(General Requirement) |
- |
2000 |
|
- |
|
14 Nov, 2027 |
- Exclusion: 19.11.4.1 (Electrostatic discharges)
19.11.4.2 (Radiated fields)
19.11.4.3 (Fast transient bursts)
19.11.4.4 (Surge immunity test)
19.11.4.5 (Immunity to conducted discharges)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.7 (Harmonics) |
| 12724 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 302 : Part 2 : Sec 35 (2017) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 35 electric instantaneous water heaters (Second Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.32(Verification) |
- |
5000 |
|
- |
| Cl.31(Verification) |
- |
5000 |
|
- |
| Cl.30(Verification) |
- |
5000 |
|
- |
| CL.29(Verification) |
- |
5000 |
|
- |
| Cl.28(Verification) |
- |
5000 |
|
- |
| Cl.27(Verification) |
- |
5000 |
|
- |
| Cl.26(Verification) |
- |
5000 |
|
- |
| Cl.25(Verification) |
- |
5000 |
|
- |
| Cl.24(Verification) |
- |
5000 |
|
- |
| Cl.23(Verification) |
- |
5000 |
|
- |
| Cl.22(Verification) |
- |
5000 |
|
- |
| Cl.21(Verification) |
- |
5000 |
|
- |
| Cl.20(Verification) |
- |
5000 |
|
- |
| Cl.19(Verification) |
- |
5000 |
|
- |
| Cl.17(Verification) |
- |
5000 |
|
- |
| Cl. 16(Verification) |
- |
5000 |
|
- |
| Cl.15(Verification) |
- |
10000 |
|
- |
| Cl.14(Verification) |
- |
0 |
|
- |
| Cl.13(Verification) |
- |
5000 |
|
- |
| Cl.11(Verification) |
- |
5000 |
|
- |
| Cl.10(Verification) |
- |
5000 |
|
- |
| Cl.8(Verification) |
- |
2000 |
|
- |
| Cl. 7(Verification) |
- |
2000 |
|
- |
| Cl. 7(Verification) |
- |
2000 |
|
- |
| Cl. 32
IS 302-2-35(Radiation, Toxicity and similar hazards) |
- |
5000 |
|
- |
| Cl. 31
IS 302-2-35(Resistance to Rusting) |
- |
5000 |
|
- |
| Cl. 30
IS 302-2-35(Resistance to Heat Fire & Tracking ) |
- |
5000 |
|
- |
| Cl. 29
IS 302-2-35(Clearances, Creepage Distances & Solid insulation ) |
- |
5000 |
|
- |
| Cl. 28
IS 302-2-35(Screws & Connections) |
- |
5000 |
|
- |
| Cl. 27
IS 302-2-35(Provision for Earthing ) |
- |
5000 |
|
- |
| Cl. 26
IS 302-2-35(Terminals for External conductors ) |
- |
5000 |
|
- |
| Cl. 25
IS 302-2-35(Supply Connection & External Flexible Cords) |
- |
5000 |
|
- |
| Cl. 24
IS 302-2-35(Components) |
- |
5000 |
|
- |
| Cl. 23
IS 302-2-35(Internal Wiring) |
- |
5000 |
|
- |
| Cl. 22
IS 302-2-35(Construction ) |
- |
5000 |
|
- |
| Cl. 21
IS 302-2-35(Mechanical strength) |
- |
5000 |
|
- |
| Cl. 20
IS 302-2-35(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| Cl. 19
IS 302-2-35(Abnormal Operation ) |
- |
5000 |
|
- |
| Cl. 18
IS 302-2-35(Endurance) |
- |
0 |
|
- |
| Cl. 17
IS 302-2-35(Overload Protection of Transformers and Associated Circuit) |
- |
5000 |
|
- |
| Cl. 16
IS 302-2-35(Leakage Current & Electric Strength at Operating Temperature (After Humidity Treatment)) |
- |
5000 |
|
- |
| Cl. 15
IS 302-2-35(Moisture Resistance Test ) |
- |
10000 |
|
- |
| Cl. 14
IS 302-2-35(Radio and television interference suppression / Transient over voltages) |
- |
0 |
|
- |
| Cl. 13
IS 302-2-35(Leakage Current & Electric Strength at Operating Temperature) |
- |
5000 |
|
- |
| Cl. 11
IS 302-2-35(Heating) |
- |
5000 |
|
- |
| Cl. 10
IS 302-2-35(Power Input and Current ) |
- |
5000 |
|
- |
| Cl. 9
IS 302-2-35(Starting of motor operated appliances) |
- |
0 |
|
- |
| Cl. 8
IS 302-2-35(Protection against access to live parts) |
- |
2000 |
|
- |
| Cl. 7
IS 302-2-35(Marking and Instruction) |
- |
2000 |
|
- |
| Cl. 6
IS 302-2-35(Classification) |
- |
2000 |
|
- |
| Cl. 32
IS 302-2-35(Radiation, Toxicity and similar hazards) |
- |
5000 |
|
- |
| Cl. 31
IS 302-2-35(Resistance to Rusting) |
- |
5000 |
|
- |
| Cl. 30
IS 302-2-35(Resistance to Heat Fire & Tracking ) |
- |
5000 |
|
- |
| Cl. 29
IS 302-2-35(Clearances, Creepage Distances & Solid insulation ) |
- |
5000 |
|
- |
| Cl. 28
IS 302-2-35(Screws & Connections) |
- |
5000 |
|
- |
| Cl. 27
IS 302-2-35(Provision for Earthing ) |
- |
5000 |
|
- |
| Cl. 26
IS 302-2-35(Terminals for External conductors ) |
- |
5000 |
|
- |
| Cl. 25
IS 302-2-35(Supply Connection & External Flexible Cords) |
- |
5000 |
|
- |
| Cl. 24
IS 302-2-35(Components) |
- |
5000 |
|
- |
| Cl. 23
IS 302-2-35(Internal Wiring) |
- |
5000 |
|
- |
| Cl. 22
IS 302-2-35(Construction ) |
- |
5000 |
|
- |
| Cl. 21
IS 302-2-35(Mechanical strength) |
- |
5000 |
|
- |
| Cl. 20
IS 302-2-35(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| Cl. 19
IS 302-2-35(Abnormal Operation ) |
- |
5000 |
|
- |
| Cl. 18
IS 302-2-35(Endurance) |
- |
0 |
|
- |
| Cl. 17
IS 302-2-35(Overload Protection of Transformers and Associated Circuit) |
- |
5000 |
|
- |
| Cl. 16
IS 302-2-35(Leakage Current & Electric Strength at Operating Temperature (After Humidity Treatment)) |
- |
5000 |
|
- |
| Cl. 15
IS 302-2-35(Moisture Resistance Test ) |
- |
5000 |
|
- |
| Cl. 14
IS 302-2-35(Radio and television interference suppression / Transient over voltages) |
- |
0 |
|
- |
| Cl. 13
IS 302-2-35(Leakage Current & Electric Strength at Operating Temperature) |
- |
5000 |
|
- |
| Cl. 11
IS 302-2-35(Heating) |
- |
5000 |
|
- |
| Cl. 10
IS 302-2-35(Power Input and Current ) |
- |
5000 |
|
- |
| Cl. 9
IS 302-2-35(Starting of motor operated appliances) |
- |
0 |
|
- |
| Cl. 8
IS 302-2-35(Protection against access to live parts) |
- |
2000 |
|
- |
| Cl. 7
IS 302-2-35(Marking and Instruction) |
- |
2000 |
|
- |
| Cl. 6
IS 302-2-35(Classification) |
- |
2000 |
|
- |
| Cl. 32
IS 302-2-35(Radiation, Toxicity and similar hazards) |
- |
5000 |
|
- |
| Cl. 31
IS 302-2-35(Resistance to Rusting) |
- |
5000 |
|
- |
| Cl. 30
IS 302-2-35(Resistance to Heat Fire & Tracking ) |
- |
5000 |
|
- |
| Cl. 29
IS 302-2-35(Clearances, Creepage Distances & Solid insulation ) |
- |
5000 |
|
- |
| Cl. 28
IS 302-2-35(Screws & Connections) |
- |
5000 |
|
- |
| Cl. 27
IS 302-2-35(Provision for Earthing ) |
- |
5000 |
|
- |
| Cl. 26
IS 302-2-35(Terminals for External conductors ) |
- |
5000 |
|
- |
| Cl. 25
IS 302-2-35(Supply Connection & External Flexible Cords) |
- |
5000 |
|
- |
| Cl. 24
IS 302-2-35(Components) |
- |
5000 |
|
- |
| Cl. 23
IS 302-2-35(Internal Wiring) |
- |
5000 |
|
- |
| Cl. 22
IS 302-2-35(Construction ) |
- |
5000 |
|
- |
| Cl. 21
IS 302-2-35(Mechanical strength) |
- |
5000 |
|
- |
| Cl. 20
IS 302-2-35(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| Cl. 19
IS 302-2-35(Abnormal Operation ) |
- |
5000 |
|
- |
| Cl. 18
IS 302-2-35(Endurance) |
- |
0 |
|
- |
| Cl. 17
IS 302-2-35(Overload Protection of Transformers and Associated Circuit) |
- |
5000 |
|
- |
| Cl. 16
IS 302-2-35(Leakage Current & Electric Strength at Operating Temperature (After Humidity Treatment)) |
- |
5000 |
|
- |
| Cl. 15
IS 302-2-35(Moisture Resistance Test ) |
- |
5000 |
|
- |
| Cl. 14
IS 302-2-35(Radio and television interference suppression / Transient over voltages) |
- |
0 |
|
- |
| Cl. 13
IS 302-2-35(Leakage Current & Electric Strength at Operating Temperature) |
- |
5000 |
|
- |
| Cl. 11
IS 302-2-35(Heating) |
- |
5000 |
|
- |
| Cl. 10
IS 302-2-35(Power Input and Current ) |
- |
5000 |
|
- |
| Cl. 9
IS 302-2-35(Starting of motor operated appliances) |
- |
0 |
|
- |
| Cl. 8
IS 302-2-35(Protection against access to live parts) |
- |
2000 |
|
- |
| Cl. 7
IS 302-2-35(Marking and Instruction) |
- |
2000 |
|
- |
| Cl. 6
IS 302-2-35(Classification) |
- |
2000 |
|
- |
| Cl. 32
IS 302-2-35(Radiation, Toxicity and similar hazards) |
- |
5000 |
|
- |
| Cl. 31
IS 302-2-35(Resistance to Rusting) |
- |
5000 |
|
- |
| Cl. 30
IS 302-2-35(Resistance to Heat Fire & Tracking ) |
- |
5000 |
|
- |
| Cl. 29
IS 302-2-35(Clearances, Creepage Distances & Solid insulation ) |
- |
5000 |
|
- |
| Cl. 28
IS 302-2-35(Screws & Connections) |
- |
5000 |
|
- |
| Cl. 27
IS 302-2-35(Provision for Earthing ) |
- |
5000 |
|
- |
| Cl. 26
IS 302-2-35(Terminals for External conductors ) |
- |
5000 |
|
- |
| Cl. 25
IS 302-2-35(Supply Connection & External Flexible Cords) |
- |
5000 |
|
- |
| Cl. 24
IS 302-2-35(Components) |
- |
5000 |
|
- |
| Cl. 23
IS 302-2-35(Internal Wiring) |
- |
5000 |
|
- |
| Cl. 22
IS 302-2-35(Construction ) |
- |
5000 |
|
- |
| Cl. 21
IS 302-2-35(Mechanical strength) |
- |
5000 |
|
- |
| Cl. 20
IS 302-2-35(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| Cl. 19
IS 302-2-35(Abnormal Operation ) |
- |
5000 |
|
- |
| Cl. 18
IS 302-2-35(Endurance) |
- |
0 |
|
- |
| Cl. 17
IS 302-2-35(Overload Protection of Transformers and Associated Circuit) |
- |
5000 |
|
- |
| Cl. 16
IS 302-2-35(Leakage Current & Electric Strength at Operating Temperature (After Humidity Treatment)) |
- |
5000 |
|
- |
| Cl. 15
IS 302-2-35(Moisture Resistance Test ) |
- |
10000 |
|
- |
| Cl. 14
IS 302-2-35(Radio and television interference suppression / Transient over voltages) |
- |
0 |
|
- |
| Cl. 13
IS 302-2-35(Leakage Current & Electric Strength at Operating Temperature) |
- |
5000 |
|
- |
| Cl. 11
IS 302-2-35(Heating) |
- |
5000 |
|
- |
| Cl. 10
IS 302-2-35(Power Input and Current ) |
- |
5000 |
|
- |
| Cl. 9
IS 302-2-35(Starting of motor operated appliances) |
- |
0 |
|
- |
| Cl. 8
IS 302-2-35(Protection against access to live parts) |
- |
2000 |
|
- |
| Cl. 7
IS 302-2-35(Marking and Instruction) |
- |
2000 |
|
- |
| Cl. 6
IS 302-2-35(Classification) |
- |
2000 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
2000 |
|
- |
| 4(GENERAL REQUIREMENT) |
- |
2000 |
|
- |
|
14 Nov, 2027 |
- Exclusion: 19.11.4.1 (Electrostatic discharges)
19.11.4.2 (Radiated fields)
19.11.4.3 (Fast transient bursts)
19.11.4.4 (Surge immunity test)
19.11.4.5 (Immunity to conducted discharges)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.7 (Harmonics) |
| 12725 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 302 : Part 2 : Sec 23 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 23 appliances for skin or hair care (First Revision) |
- |
24500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification) |
- |
2000 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
2000 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 10(Power Input
& Current) |
- |
5000 |
|
- |
| 11(Temperature Rise/Heating) |
- |
5000 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
5000 |
|
- |
| 14(Transient Over Voltage) |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
5000 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal wiring) |
- |
5000 |
|
- |
| 24(Component) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 28(Screws & Connection) |
- |
5000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
5000 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
5000 |
|
- |
| 31(Resistance to Rusting) |
- |
5000 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
5000 |
|
- |
| 6(Classification) |
- |
2000 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
2000 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 10(Power Input
& Current) |
- |
5000 |
|
- |
| 11(Temperature Rise/Heating) |
- |
5000 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
5000 |
|
- |
| 14(Transient Over Voltage) |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
5000 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal wiring) |
- |
5000 |
|
- |
| 24(Component) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 28(Screws & Connection) |
- |
5000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
5000 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
5000 |
|
- |
| 31(Resistance to Rusting) |
- |
5000 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
5000 |
|
- |
| 6(Classification) |
- |
2000 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
2000 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 10(Power Input
& Current) |
- |
5000 |
|
- |
| 11(Temperature Rise/Heating) |
- |
5000 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
5000 |
|
- |
| 14(Transient Over Voltage) |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
5000 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal wiring) |
- |
5000 |
|
- |
| 24(Component) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 28(Screws & Connection) |
- |
5000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
5000 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
5000 |
|
- |
| 31(Resistance to Rusting) |
- |
5000 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
5000 |
|
- |
| 22.32(CONSTRUCTION) |
- |
5000 |
|
- |
|
14 Nov, 2027 |
- - |
| 12726 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
- |
16500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
2000 |
|
- |
| 7(Marking and instructions) |
- |
2000 |
|
- |
| 8(Protection against live parts) |
- |
2000 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
5000 |
|
- |
| 11(HEATING) |
- |
5000 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
5000 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
5000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
10000 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
5000 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
5000 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
5000 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
5000 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
5000 |
|
- |
| 22(CONSTRUCTION) |
- |
5000 |
|
- |
| 23(INTERNAL WIRING) |
- |
5000 |
|
- |
| 24(COMPONENTS) |
- |
5000 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
5000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
5000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
5000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
5000 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
5000 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
5000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
5000 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
5000 |
|
- |
| 22.16(Automatic cord reel) |
- |
5000 |
|
- |
| 22.32(Oxygen bomb for rubber material) |
- |
5000 |
|
- |
| 22.47(Water pressure inlet) |
- |
5000 |
|
- |
| 22.106(Interlocks) |
- |
5000 |
|
- |
| 22.3(Flexing test) |
- |
5000 |
|
- |
| 24(Components) |
- |
5000 |
|
- |
| 4(General requirements) |
- |
2000 |
|
- |
| 5(General Conditions of tests) |
- |
2000 |
|
- |
| 6.0(Classification) |
- |
2000 |
|
- |
| 7(Marking and instructions) |
- |
2000 |
|
- |
| 8(Protection against live parts) |
- |
2000 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
5000 |
|
- |
| 11(HEATING) |
- |
5000 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
5000 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
5000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
10000 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
5000 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
5000 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
5000 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
5000 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
5000 |
|
- |
| 22(CONSTRUCTION) |
- |
5000 |
|
- |
| 23(INTERNAL WIRING) |
- |
5000 |
|
- |
| 24(COMPONENTS) |
- |
5000 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
5000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
5000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
5000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
5000 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
5000 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
5000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
5000 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
5000 |
|
- |
| 22.16(Automatic cord reel) |
- |
5000 |
|
- |
| 22.32(Oxygen bomb for rubber material) |
- |
5000 |
|
- |
| 22.47(Water pressure inlet) |
- |
5000 |
|
- |
| 22.106(Interlocks) |
- |
5000 |
|
- |
| 22.3(Flexing test) |
- |
5000 |
|
- |
| 24(Components) |
- |
5000 |
|
- |
| 4(General requirements) |
- |
2000 |
|
- |
| 5(General Conditions of tests) |
- |
2000 |
|
- |
| 6.0(Classification) |
- |
2000 |
|
- |
| 7(Marking and instructions) |
- |
2000 |
|
- |
| 8(Protection against live parts) |
- |
2000 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
5000 |
|
- |
| 11(HEATING) |
- |
5000 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
5000 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
5000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
10000 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
5000 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
5000 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
5000 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
5000 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
5000 |
|
- |
| 22(CONSTRUCTION) |
- |
5000 |
|
- |
| 23(INTERNAL WIRING) |
- |
5000 |
|
- |
| 24(COMPONENTS) |
- |
5000 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
5000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
5000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
5000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
5000 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
5000 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
5000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
5000 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
5000 |
|
- |
| 22.16(Automatic cord reel) |
- |
5000 |
|
- |
| 22.32(Oxygen bomb for rubber material) |
- |
5000 |
|
- |
| 22.47(Water pressure inlet) |
- |
5000 |
|
- |
| 22.106(Interlocks) |
- |
5000 |
|
- |
| 22.3(Flexing test) |
- |
5000 |
|
- |
| 24(Components) |
- |
5000 |
|
- |
| 4(General requirements) |
- |
2000 |
|
- |
| 5(General Conditions of tests) |
- |
2000 |
|
- |
| 6.0(Classification) |
- |
2000 |
|
- |
| 7(Marking and instructions) |
- |
2000 |
|
- |
| 8(Protection against live parts) |
- |
2000 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
5000 |
|
- |
| 11(HEATING) |
- |
5000 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
5000 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
5000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
10000 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
5000 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
5000 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
5000 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
5000 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
5000 |
|
- |
| 22(CONSTRUCTION) |
- |
5000 |
|
- |
| 23(INTERNAL WIRING) |
- |
5000 |
|
- |
| 24(COMPONENTS) |
- |
5000 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
5000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
5000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
5000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
5000 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
5000 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
5000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
5000 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
5000 |
|
- |
| 24(Components) |
- |
5000 |
|
- |
| 4(General requirements) |
- |
2000 |
|
- |
| 5(General Conditions of tests) |
- |
2000 |
|
- |
|
14 Nov, 2027 |
- Exclusion: 19.11.4.1 (Electrostatic discharges)
19.11.4.2 (Radiated fields)
19.11.4.3 (Fast transient bursts)
19.11.4.4 (Surge immunity test)
19.11.4.5 (Immunity to conducted discharges)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.7 (Harmonics)
22.16 (Automatic cord reel)
22.32 (Oxygen bomb for rubber material)
22.47 (Water pressure inlet)
22.106 (Interlocks)
22.3 (Flexing test) |
| 12727 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 302 : Part 2 : Sec 13 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 13 frying pans, deep fat fryers and similar appliances |
- |
24000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32(Radiation ,Toxicity and similar hazards) |
- |
5000 |
|
- |
| 31(Resistance to Rusting) |
- |
5000 |
|
- |
| 30(Resistance to Heat, Fire and Tracking) |
- |
5000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
5000 |
|
- |
| 28(Screws & Connections) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
5000 |
|
- |
| 24(Components) |
- |
5000 |
|
- |
| 23(Internal wiring) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
5000 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 14(Transient Over Voltage) |
- |
5000 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
5000 |
|
- |
| 11(Temperature Rise/Heating) |
- |
5000 |
|
- |
| 10(Power Input) |
- |
5000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
2000 |
|
- |
| 6(Classification) |
- |
2000 |
|
- |
| 5(Rating) |
- |
2000 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
5000 |
|
- |
| 31(Resistance to Rusting) |
- |
5000 |
|
- |
| 30(Resistance to Heat, Fire and Tracking) |
- |
5000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
5000 |
|
- |
| 28(Screws & Connections) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
5000 |
|
- |
| 24(Components) |
- |
5000 |
|
- |
| 23(Internal wiring) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
5000 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 14(Transient Over Voltage) |
- |
5000 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
5000 |
|
- |
| 11(Temperature Rise/Heating) |
- |
5000 |
|
- |
| 10(Power Input) |
- |
5000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
2000 |
|
- |
| 6(Classification) |
- |
2000 |
|
- |
| 5(Rating) |
- |
2000 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
5000 |
|
- |
| 31(Resistance to Rusting) |
- |
5000 |
|
- |
| 30(Resistance to Heat, Fire and Tracking) |
- |
5000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
5000 |
|
- |
| 28(Screws & Connections) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
5000 |
|
- |
| 24(Components) |
- |
5000 |
|
- |
| 23(Internal wiring) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
5000 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 14(Transient Over Voltage) |
- |
5000 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
5000 |
|
- |
| 11(Temperature Rise/Heating) |
- |
5000 |
|
- |
| 10(Power Input) |
- |
5000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
2000 |
|
- |
| 6(Classification) |
- |
2000 |
|
- |
| 5(Rating) |
- |
2000 |
|
- |
|
14 Nov, 2027 |
- Exclusion: 19.11.4.1 (Electrostatic discharges)
19.11.4.2 (Radiated fields)
19.11.4.3 (Fast transient bursts)
19.11.4.4 (Surge immunity test)
19.11.4.5 (Immunity to conducted discharges)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.7 (Harmonics) |
| 12728 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 302 : Part 2 : Sec 8 (1994) |
Safety of household and similar electrical appliances : part 2 particular requirements, section 8 electrical shavers hair, clippers and similar appliances |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Rating) |
- |
2000 |
|
- |
| 6(Classification) |
- |
2000 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
2000 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
2000 |
|
- |
| 10(Power Input
& Current) |
- |
5000 |
|
- |
| 11(Temperature Rise/Heating) |
- |
5000 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
5000 |
|
- |
| 14(Radio and Television Interference Suppression/ Transient Over Voltage) |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
5000 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal wiring) |
- |
5000 |
|
- |
| 24(Component) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 28(Screws & Connection) |
- |
5000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
5000 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
5000 |
|
- |
| 31(Resistance to Rusting) |
- |
5000 |
|
- |
| 5(Rating) |
- |
2000 |
|
- |
| 6(Classification) |
- |
2000 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
2000 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
2000 |
|
- |
| 10(Power Input
& Current) |
- |
5000 |
|
- |
| 11(Temperature Rise/Heating) |
- |
5000 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
5000 |
|
- |
| 14(Radio and Television Interference Suppression/ Transient Over Voltage) |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
5000 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal wiring) |
- |
5000 |
|
- |
| 24(Component) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 28(Screws & Connection) |
- |
5000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
5000 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
5000 |
|
- |
| 31(Resistance to Rusting) |
- |
5000 |
|
- |
| 5(Rating) |
- |
2000 |
|
- |
| 6(Classification) |
- |
2000 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
2000 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
2000 |
|
- |
| 10(Power Input
& Current) |
- |
5000 |
|
- |
| 11(Temperature Rise/Heating) |
- |
5000 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
5000 |
|
- |
| 14(Radio and Television Interference Suppression/ Transient Over Voltage) |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
5000 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal wiring) |
- |
5000 |
|
- |
| 24(Component) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 28(Screws & Connection) |
- |
5000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
5000 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
5000 |
|
- |
| 31(Resistance to Rusting) |
- |
5000 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
0 |
|
- |
| 5(Rating) |
- |
2000 |
|
- |
| 6(Classification) |
- |
2000 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
2000 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
2000 |
|
- |
| 10(Power Input
& Current) |
- |
5000 |
|
- |
| 11(Temperature Rise/Heating) |
- |
5000 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
5000 |
|
- |
| 14(Radio and Television Interference Suppression/ Transient Over Voltage) |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
5000 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal wiring) |
- |
5000 |
|
- |
| 24(Component) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 28(Screws & Connection) |
- |
5000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
5000 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
5000 |
|
- |
| 31(Resistance to Rusting) |
- |
5000 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
0 |
|
- |
|
14 Nov, 2027 |
- Cl.19.11.4.1 to Cl.19.11.4.7 (EMI/EMC) |
| 12729 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 302 : Part 2 : Sec 7 (2010) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 7 domestic electric clothes washing machines (First Revision) |
- |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification) |
- |
2000 |
|
- |
| 7(Marking) |
- |
2000 |
|
- |
| 8(Protection against access to live parts) |
- |
2000 |
|
- |
| 9(Starting of Motor operated appliances) |
- |
0 |
|
- |
| 10(Power Input
& Current
) |
- |
5000 |
|
- |
| 11(Temperature Rise/ Heating) |
- |
5000 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
5000 |
|
- |
| 14(Transient Over Voltage) |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
5000 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
10000 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal wiring) |
- |
5000 |
|
- |
| 24(Components) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cords) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 28(Screws & Connections) |
- |
5000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
5000 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
5000 |
|
- |
| 31(Resistance to Rusting) |
- |
2000 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
2000 |
|
- |
| 6(Classification) |
- |
2000 |
|
- |
| 7(Marking) |
- |
2000 |
|
- |
| 8(Protection against access to live parts) |
- |
2000 |
|
- |
| 9(Starting of Motor operated appliances) |
- |
0 |
|
- |
| 10(Power Input
& Current
) |
- |
5000 |
|
- |
| 11(Temperature Rise/ Heating) |
- |
5000 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
5000 |
|
- |
| 14(Transient Over Voltage) |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
5000 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
10000 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal wiring) |
- |
5000 |
|
- |
| 24(Components) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cords) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 28(Screws & Connections) |
- |
5000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
5000 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
5000 |
|
- |
| 31(Resistance to Rusting) |
- |
2000 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
2000 |
|
- |
| 6(Classification) |
- |
2000 |
|
- |
| 7(Marking) |
- |
2000 |
|
- |
| 8(Protection against access to live parts) |
- |
2000 |
|
- |
| 9(Starting of Motor operated appliances) |
- |
0 |
|
- |
| 10(Power Input
& Current
) |
- |
5000 |
|
- |
| 11(Temperature Rise/ Heating) |
- |
5000 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
5000 |
|
- |
| 14(Transient Over Voltage) |
- |
5000 |
|
- |
| 15(Moisture Resistance) |
- |
10000 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
5000 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
10000 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal wiring) |
- |
5000 |
|
- |
| 24(Components) |
- |
5000 |
|
- |
| 25(Supply Connection & External Flexible Cords) |
- |
5000 |
|
- |
| 26(Terminals For External Conductors) |
- |
5000 |
|
- |
| 27(Provision For Earthing) |
- |
5000 |
|
- |
| 28(Screws & Connections) |
- |
5000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
5000 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
5000 |
|
- |
| 31(Resistance to Rusting) |
- |
2000 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
2000 |
|
- |
| 4(GENERAL REQUIREMENTS) |
- |
2000 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
2000 |
|
- |
|
14 Nov, 2027 |
- Exclusion: 19.11.4.1 (Electrostatic discharges)
19.11.4.2 (Radiated fields)
19.11.4.3 (Fast transient bursts)
19.11.4.4 (Surge immunity test)
19.11.4.5 (Immunity to conducted discharges)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.7 (Harmonics) |
| 12730 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Requirements) |
- |
2000 |
|
- |
| 5(General condition for the tests) |
- |
2000 |
|
- |
| 6.0(Classification) |
- |
2000 |
|
- |
| 7.0(Marking and instructions) |
- |
2000 |
|
- |
| 8.0(Protection against access to live part test) |
- |
2000 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
0 |
|
- |
| 10.0(Power Input and current test) |
- |
5000 |
|
- |
| 11.0(Heating test) |
- |
5000 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
5000 |
|
- |
| 14.0(Transient voltages) |
- |
5000 |
|
- |
| 15.0(Moisture Resistance) |
- |
10000 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
5000 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
5000 |
|
- |
| 18.0(Endurance test) |
- |
0 |
|
- |
| 19.0(Abnormal Operations) |
- |
5000 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
5000 |
|
- |
| 21.0(Mechanical Strength) |
- |
5000 |
|
- |
| 22.0(Construction verification related tests) |
- |
5000 |
|
- |
| 23.0(Internal wiring) |
- |
5000 |
|
- |
| 24.0(Components) |
- |
5000 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
5000 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
5000 |
|
- |
| 27.0(Provision for Earthing) |
- |
5000 |
|
- |
| 28.0(Screws and connections) |
- |
5000 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
5000 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
5000 |
|
- |
| 31.0(Resistance to rusting) |
- |
2000 |
|
- |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
5000 |
|
- |
| 4(General Requirements) |
- |
2000 |
|
- |
| 5(General condition for the tests) |
- |
2000 |
|
- |
| 6.0(Classification) |
- |
2000 |
|
- |
| 7.0(Marking and instructions) |
- |
2000 |
|
- |
| 8.0(Protection against access to live part test) |
- |
2000 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
0 |
|
- |
| 10.0(Power Input and current test) |
- |
5000 |
|
- |
| 11.0(Heating test) |
- |
5000 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
5000 |
|
- |
| 14.0(Transient voltages) |
- |
5000 |
|
- |
| 15.0(Moisture Resistance) |
- |
10000 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
5000 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
5000 |
|
- |
| 18.0(Endurance test) |
- |
0 |
|
- |
| 19.0(Abnormal Operations) |
- |
5000 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
5000 |
|
- |
| 21.0(Mechanical Strength) |
- |
5000 |
|
- |
| 22.0(Construction verification related tests) |
- |
5000 |
|
- |
| 23.0(Internal wiring) |
- |
5000 |
|
- |
| 24.0(Components) |
- |
5000 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
5000 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
5000 |
|
- |
| 27.0(Provision for Earthing) |
- |
5000 |
|
- |
| 28.0(Screws and connections) |
- |
5000 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
5000 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
5000 |
|
- |
| 31.0(Resistance to rusting) |
- |
2000 |
|
- |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
5000 |
|
- |
| 4(General Requirements) |
- |
2000 |
|
- |
| 5(General condition for the tests) |
- |
2000 |
|
- |
| 6.0(Classification) |
- |
2000 |
|
- |
| 7.0(Marking and instructions) |
- |
2000 |
|
- |
| 8.0(Protection against access to live part test) |
- |
2000 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
0 |
|
- |
| 10.0(Power Input and current test) |
- |
5000 |
|
- |
| 11.0(Heating test) |
- |
5000 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
5000 |
|
- |
| 14.0(Transient voltages) |
- |
5000 |
|
- |
| 15.0(Moisture Resistance) |
- |
10000 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
5000 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
5000 |
|
- |
| 18.0(Endurance test) |
- |
0 |
|
- |
| 19.0(Abnormal Operations) |
- |
5000 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
5000 |
|
- |
| 21.0(Mechanical Strength) |
- |
5000 |
|
- |
| 22.0(Construction verification related tests) |
- |
5000 |
|
- |
| 23.0(Internal wiring) |
- |
5000 |
|
- |
| 24.0(Components) |
- |
5000 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
5000 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
5000 |
|
- |
| 27.0(Provision for Earthing) |
- |
5000 |
|
- |
| 28.0(Screws and connections) |
- |
5000 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
5000 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
5000 |
|
- |
| 31.0(Resistance to rusting) |
- |
5000 |
|
- |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
5000 |
|
- |
|
14 Nov, 2027 |
- Exclusion: 19.11.4.1 (Electrostatic discharges)
19.11.4.2 (Radiated fields)
19.11.4.3 (Fast transient bursts)
19.11.4.4 (Surge immunity test)
19.11.4.5 (Immunity to conducted discharges)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.7 (Harmonics) |
| 12731 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 320 (1980) |
Specification for high tensile brass rods and sections (Other Than Forging Stock) (Second Revision) |
- |
6500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Tin Is 3685:1966/BS EN 15079:2015) |
- |
4500 |
|
For Complete Chemical Test |
| 4(Lead IS 3685:1966/BS EN 15079:2015) |
- |
4500 |
|
For Complete Chemical Test |
| 4(Iron IS 3685:1966/BS EN 15079:2015) |
- |
4500 |
|
For Complete Chemical Test |
| 4(Manganese IS 3685:1966/BS EN 15079:2015) |
- |
4500 |
|
For Complete Chemical Test |
| 4(Aluminium IS 3685:1966/BS EN 15079:2015) |
- |
4500 |
|
For Complete Chemical Test |
| 4(Antimony IS 3685:1966/BS EN 15079:2015) |
- |
4500 |
|
For Complete Chemical Test |
| 4(Zinc IS 3685:1966/BS EN 15079:2015) |
- |
4500 |
|
For Complete Chemical Test |
| 6(Tensile Test IS 2654:1964) |
- |
2000 |
|
For Complete Mechanical Test |
| 6.2(Mercurous Nitrate Test IS 2305:1962) |
- |
4500 |
|
For Complete Chemical Test |
| 8(Size and Tolerance IS 2826:1980) |
- |
2000 |
|
For Complete Mechanical Test |
| 4(Tin Is 3685:1966/BS EN 15079:2015) |
- |
0 |
|
- |
| 4(Lead IS 3685:1966/BS EN 15079:2015) |
- |
0 |
|
- |
| 4(Iron IS 3685:1966/BS EN 15079:2015) |
- |
0 |
|
- |
| 4(Manganese IS 3685:1966/BS EN 15079:2015) |
- |
0 |
|
- |
| 4(Aluminium IS 3685:1966/BS EN 15079:2015) |
- |
0 |
|
- |
| 4(Antimony IS 3685:1966/BS EN 15079:2015) |
- |
0 |
|
- |
| 4(Zinc IS 3685:1966/BS EN 15079:2015) |
- |
0 |
|
- |
| 6(Tensile Test IS 2654:1964) |
- |
0 |
|
- |
| 6.2(Mercurous Nitrate Test IS 2305:1962) |
- |
0 |
|
- |
| 8(Size and Tolerance IS 2826:1980) |
- |
0 |
|
- |
|
04 Dec, 2028 |
- Included w.e.f. 06-07-2023. |
| 12732 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 6911 (2017) |
Stainless steel plate, sheet and strip - Specification (Second Revision) |
- |
17000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.1,Table 4&Table 6(Tensile Test - IS 1608(Pt -1)) |
- |
5000 |
|
For Complete Cl 10 |
| 10.2,Table 4&Table 5(Hardness Test- IS 1500(Pt -1),IS 1501 (Pt-1),IS 1586 (Pt -1)) |
- |
5000 |
|
For Complete Cl 10 |
| 17(Dimension and tolerance) |
- |
3000 |
|
For Complete Cl 17 |
| 10.3(Bend Test - IS 1599) |
- |
5000 |
|
For Complete Cl 10 |
| 12(Corrosion resistance) |
- |
5000 |
|
For Complete Cl 12 |
| 10.1,Table 4&Table 6(Tensile Test - IS 1608(Pt -1)) |
- |
0 |
|
- |
| 10.2,Table 4&Table 5(Hardness Test- IS 1500(Pt -1),IS 1501 (Pt-1),IS 1586 (Pt -1)) |
- |
0 |
|
- |
| 17(Dimension and tolerance) |
- |
0 |
|
- |
| 10.3(Bend Test - IS 1599) |
- |
0 |
|
- |
| 12(Corrosion resistance) |
- |
0 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
4000 |
|
For complete chemical test |
| Cl. 7.1 & 7.2 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
4000 |
|
For complete chemical test |
| Cl. 7.1 & 7.2 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
4000 |
|
For complete chemical test |
| Cl. 7.1 & 7.2 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
4000 |
|
For complete chemical test |
| Cl. 7.1 & 7.2 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
4000 |
|
For complete chemical test |
| Cl. 7.1 & 7.2 Table 1(Molybdenum -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
4000 |
|
For complete chemical test |
| Cl. 7.1 & 7.2 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
4000 |
|
For complete chemical test |
| Cl. 7.1 & 7.2 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
4000 |
|
For complete chemical test |
| Cl. 7.1 & 7.2 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
4000 |
|
For complete chemical test |
| Cl. 7.1 & 7.2 Table 1(Copper -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
4000 |
|
For complete chemical test |
| Cl. 7.1 & 7.2 Table 1(Titanium-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
4000 |
|
For complete chemical test |
| Cl. 7.1 & 7.2 Table 1(Niobium-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
4000 |
|
For complete chemical test |
|
04 Dec, 2028 |
- Included w.e.f. 06-07-2023. |
| 12733 |
Eureka Analytical Services Private Limited, Bengaluru
| 6171206
| IS 11536 (2022) |
Processed Cereal Based Complementary Foods ? Specification ( Third Revision ) |
IS 11536 |
52000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.10,Table 2 ,Sl No i)(Aerobic plate count) |
- |
350 |
|
- |
| Clause 4.10,Table 2 ,Sl No ii)(Coliform Count) |
- |
350 |
|
- |
| Clause 4.10,Table 2 ,Sl No iii)(Staphylococcus aureus (Coagulase positive)) |
- |
550 |
|
- |
| Clause 4.10,Table 2 ,Sl No iv)(Yeast and mould count) |
- |
450 |
|
- |
| Clause 4.10,Table 2 ,Sl No v)(Salmonella sp.) |
- |
550 |
|
- |
| "4.10 Table 2 (vi) "(Listeria monocytogenes-IS 14988 (Part 1)) |
- |
550 |
|
- |
| "4.10 Table 2 (vii) "(Bacillus cereus-IS 5887 (Part 6)) |
- |
550 |
|
- |
| Clause 4.10,Table 2 ,Sl No viii)(Sulphite reducing clostridia) |
- |
550 |
|
- |
| Clause 4.10,Table 2 ,Sl No ix)(Escherichia coli) |
- |
350 |
|
- |
| 4.13, Table 3 (i)(Lead - IS 12074 or AOAC 2015.01) |
- |
425 |
|
- |
| 4.13, Table 3 (iii)(Arsenic - IS 11124 or AOAC 2015.01) |
- |
425 |
|
- |
| 4.13, Table 3 (v)(Cadimum - 15 of IS 1699 or AOAC 2015.01) |
- |
425 |
|
- |
| 4.6(Sodium-IS 12760) |
- |
425 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No i)(Moisture) |
- |
300 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No ii)(Total Protein) |
- |
550 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No iii)(Total Fat) |
- |
550 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No iV)(Total Carbohydrates) |
- |
200 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No v)(Total Ash) |
- |
350 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No vi)(Acid insoluble ash in dilute hydrochloric acid) |
- |
550 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No vii)(Iron) |
- |
425 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No viii)(Vitamin A (as Retinol equivalent RE)) |
- |
2000 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xi)(Crude fibre (on dry basis)) |
- |
425 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No ix)(Vitamin C) |
- |
1500 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xii)(Thiamine) |
- |
2500 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xiii)(Riboflavin) |
- |
2200 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xiv)(Niacin equivalent) |
- |
2200 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xv)(Pantothenic acid) |
- |
2300 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xvi)(Pyridoxine) |
- |
2500 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xvii)(Biotine) |
- |
3200 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xviii)(Dietary folate equivalent (DFE)2)) |
- |
3200 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xix)(Vitamin B12) |
- |
3200 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xx)(Zinc) |
- |
425 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xxi)(Choline) |
- |
2500 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xxii)(Inositol) |
- |
3000 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xxiii)(Selenium) |
- |
300 |
|
- |
| Clause 4.13,Table 3 ,Sl No ii)(Copper) |
- |
425 |
|
- |
| Clause 4.13,Table 3 ,Sl No iv)(Tin) |
- |
425 |
|
- |
| Clause 4.13,Table 3 ,Sl No vi)(Melamine) |
- |
2500 |
|
- |
| Clause 4.13,Table 3 ,Sl No vii)(Total aflatoxin) |
- |
3000 |
|
- |
| Clause 4.13,Table 3 ,Sl No viii)(Aflatoxin B1) |
- |
3000 |
|
- |
| 4.1(Description- IS 11536) |
- |
100 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No x)(Vitamon D) |
- |
3500 |
|
- |
| Clause 4.10,Table 2 ,Sl No i)(Aerobic plate count) |
- |
350 |
|
- |
| Clause 4.10,Table 2 ,Sl No ii)(Coliform Count) |
- |
350 |
|
- |
| Clause 4.10,Table 2 ,Sl No iii)(Staphylococcus aureus (Coagulase positive)) |
- |
550 |
|
- |
| Clause 4.10,Table 2 ,Sl No iv)(Yeast and mould count) |
- |
450 |
|
- |
| Clause 4.10,Table 2 ,Sl No v)(Salmonella sp.) |
- |
550 |
|
- |
| "4.10 Table 2 (vi) "(Listeria monocytogenes-IS 14988 (Part 1)) |
- |
550 |
|
- |
| "4.10 Table 2 (vii) "(Bacillus cereus-IS 5887 (Part 6)) |
- |
550 |
|
- |
| Clause 4.10,Table 2 ,Sl No viii)(Sulphite reducing clostridia) |
- |
550 |
|
- |
| Clause 4.10,Table 2 ,Sl No ix)(Escherichia coli) |
- |
350 |
|
- |
| 4.13, Table 3 (i)(Lead - IS 12074 or AOAC 2015.01) |
- |
425 |
|
- |
| 4.13, Table 3 (iii)(Arsenic - IS 11124 or AOAC 2015.01) |
- |
425 |
|
- |
| 4.13, Table 3 (v)(Cadimum - 15 of IS 1699 or AOAC 2015.01) |
- |
425 |
|
- |
| 4.6(Sodium-IS 12760) |
- |
425 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No i)(Moisture) |
- |
300 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No ii)(Total Protein) |
- |
550 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No iii)(Total Fat) |
- |
500 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No iV)(Total Carbohydrates) |
- |
200 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No v)(Total Ash) |
- |
350 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No vi)(Acid insoluble ash in dilute hydrochloric acid) |
- |
550 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No vii)(Iron) |
- |
425 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No viii)(Vitamin A (as Retinol equivalent RE)) |
- |
2000 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xi)(Crude fibre (on dry basis)) |
- |
425 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No ix)(Vitamin C) |
- |
1500 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xii)(Thiamine) |
- |
2500 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xiii)(Riboflavin) |
- |
2200 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xiv)(Niacin equivalent) |
- |
2200 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xv)(Pantothenic acid) |
- |
2300 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xvi)(Pyridoxine) |
- |
2500 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xvii)(Biotine) |
- |
3200 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xviii)(Dietary folate equivalent (DFE)2)) |
- |
3200 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xix)(Vitamin B12) |
- |
3200 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xx)(Zinc) |
- |
425 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xxi)(Choline) |
- |
2500 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xxii)(Inositol) |
- |
3000 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No xxiii)(Selenium) |
- |
425 |
|
- |
| Clause 4.13,Table 3 ,Sl No ii)(Copper) |
- |
425 |
|
- |
| Clause 4.13,Table 3 ,Sl No iv)(Tin) |
- |
425 |
|
- |
| Clause 4.13,Table 3 ,Sl No vi)(Melamine) |
- |
2500 |
|
- |
| Clause 4.13,Table 3 ,Sl No vii)(Total aflatoxin) |
- |
3000 |
|
- |
| Clause 4.13,Table 3 ,Sl No viii)(Aflatoxin B1) |
- |
3000 |
|
- |
| 4.1(Description- IS 11536) |
- |
100 |
|
- |
| Clause 4.7.2 and 4.10,Table 1 ,Sl No x)(Vitamon D) |
- |
3500 |
|
- |
|
02 Aug, 2028 |
- Revised Version of IS 11536:2022. Included w.e.f. 17.02.2023 |
| 12734 |
SWASTIK ELECTRONICS TESTING CENTRE (OPC) PVT. LTD., GHAZIABAD
| 8163826
| IS 16333 : Part 3 (2022) |
Mobile phone handsets: Part 3 Indian language support for mobile phone handsets - Specific requirements(Second Revision) |
-- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Inputting of text) |
- |
7000 |
|
- |
| 5.2(Message Readability) |
- |
7000 |
|
- |
| 6(Marking) |
- |
1000 |
|
- |
|
15 May, 2028 |
- Revised Version of IS 16333(Part-3):2022. Included w.e.f. 17.05.2023 |
| 12735 |
Central Institute of Petrochemicals Engineering & Technology (CIPET), Chandrapur
| 7173804
| IS 13488 (2008) |
Irrigation equipment - Emitting pipe systems - Specification (First Revision) |
OD up to 25 mm & Class 1 to 4 |
14219 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.2 (Ref. Cl 4.1.c.i of IS 12786 : 1989)(Density) |
- |
1125 |
|
500 for testing & 625 for sheet preparation. |
| 5.1.2 (Ref. Cl 4.1.c & 4.2.a of IS 12786 : 1989)(Carbon Black content - IS 2530 : 1963) |
- |
925 |
|
- |
| 5.1.2 (Ref. Cl 4.2.b of IS 12786 : 1989)(The dispersion of Carbon Black content shall be satisfactory - IS 2530 : 1963) |
- |
700 |
|
- |
| 5.1.2 (Ref. Cl 4.1.c.iii of IS 12786 : 1989)(Volatile matter - Annex B of IS 12786:1989) |
- |
700 |
|
- |
| 6.3(General) |
- |
300 |
|
- |
| 8.1.2(Uniformity of Emission Rate for Unregulated Emitting Pipes) |
- |
1000 |
|
- |
| 8.3.1(Wall Thickness ofEmitting Pipe) |
- |
250 |
|
- |
| 8.1.3(Uniformity of Emission Rate for Regulated Emitting Pipes) |
- |
1000 |
|
- |
| 8.2(Emission Rate of Emitting Unit as a Function of Inlet Pressure) |
- |
1000 |
|
- |
| 8.2.1(Unregu/Qt~d Emining Pipe) |
- |
1000 |
|
- |
| 8.2.2(Regulated Emitting Pipes) |
- |
1000 |
|
- |
| 8.3.3(Flow Paths in Emitting Unit) |
- |
400 |
|
- |
| 8.3.4(Spacing ofEmitter Units) |
- |
400 |
|
- |
| 8.4.1(Resistance to Hydrostatic Pressure at Ambient Temperature) |
- |
1000 |
|
- |
| 8.4.2(Resistance to Hydrostatic Pressure at Elevated Temperature) |
- |
1600 |
|
- |
| 8.5(Resistance to Tension at Elevated Temperature) |
- |
1100 |
|
- |
| 8.6(Resistance to Pull Out of Joints Between Fitting and Emitting
IS 13479) |
- |
400 |
|
- |
| 8.7.1(Resistance of PE Emitting Pipe to
Environmental Stress Cracking -Acceptance Test
Annex D of IS 12786) |
- |
1200 |
|
- |
| 8.7.2(Resistance of PE Emitting Pipe to
Environmental Stress Cracking - Type Test
Annex D of IS 12786) |
- |
1600 |
|
- |
| 9.1(DESIGNATION - Non regulated Emitting Pipe) |
- |
300 |
|
- |
| 9.2(DESIGNATION - Regulated Emitting Pipe) |
- |
300 |
|
- |
| 8.3.2(Inside Diameter ofEmitting Pipe) |
- |
250 |
|
- |
| 8.8(Determination of Emitting Unit Exponent) |
- |
600 |
|
- |
| 5.1(Materials - shall be resistant to fertilizers and
chemicals commonly employed in irrigation, and shall
be suitable for use with water at temperatures up to
60°C and at pressures designed for the emitting pipe) |
- |
300 |
|
- |
|
10 Sep, 2029 |
- Exclusion: Cl. 5.1.2 (Potyethylene - higher olefins constituent, Potyethylene - anti-oxidant, Density, Toluene extract - Annex A) |
| 12736 |
ABSOLUTE TESTING SERVICES, FARIDABAD
| 8174526
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.5(Components) |
- |
5500 |
|
- |
| 1.6(Power interface .) |
- |
5500 |
|
- |
| 1.7(Markings and instructions) |
- |
5500 |
|
- |
| 2.1(Protection from electric shock and energy hazards) |
- |
5500 |
|
- |
| 2.2(SELV circuits) |
- |
5500 |
|
- |
| 2.3(TNV circuits) |
- |
5500 |
|
- |
| 2.4(Limited current circuits) |
- |
5500 |
|
- |
| 2.5(Limited power sources .) |
- |
5500 |
|
- |
| 2.6(Provisions for earthing and bonding) |
- |
5500 |
|
- |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
5500 |
|
- |
| 2.8(Safety interlocks) |
- |
5500 |
|
- |
| 2.9(Electrical insulation) |
- |
5500 |
|
- |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
5500 |
|
- |
| 3.1(General) |
- |
5500 |
|
- |
| 3.2(Connection to a mains supply) |
- |
5500 |
|
- |
| 3.3(Wiring terminals for connection of external conductors) |
- |
5500 |
|
- |
| 3.4(Disconnection from the mains supply) |
- |
5500 |
|
- |
| 3.5(Interconnection of equipment) |
- |
5500 |
|
- |
| 4.1(Stability) |
- |
5500 |
|
- |
| 4.2(Mechanical strength) |
- |
5500 |
|
- |
| 4.3(Design and construction) |
- |
5500 |
|
- |
| 4.4(Protection against hazardous moving parts) |
- |
5500 |
|
- |
| 4.5(Thermal requirements) |
- |
5500 |
|
- |
| 4.6(Openings in enclosures) |
- |
5500 |
|
- |
| 4.7(Resistance to fire) |
- |
5500 |
|
- |
| 5.1(Touch current and protective conductor curren) |
- |
5500 |
|
- |
| 5.2(Electric strength) |
- |
5500 |
|
- |
| 5.3(Abnormal operating and fault conditions) |
- |
5500 |
|
- |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
5500 |
|
- |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
5500 |
|
- |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
5500 |
|
- |
| 7.1(General) |
- |
5500 |
|
- |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
5500 |
|
- |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
5500 |
|
- |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
5500 |
|
- |
| 1.5(Components) |
- |
5500 |
|
- |
| 2.8.2/2.8.5(Interlock switches) |
- |
5500 |
|
- |
| 2.8.7(Switches and Relay) |
- |
5500 |
|
- |
| 2.10.4.2(Material Group and Comparative Tracking Index) |
- |
5500 |
|
- |
| 2.10.5.3(Insulating Compound as Solid Insulation) |
- |
5500 |
|
- |
| 2.10.5.4(Opto-coupler) |
- |
5500 |
|
- |
| 2.10.5.6(Thin sheet materials) |
- |
5500 |
|
- |
| 2.10.5.11(SMPS Transformer and Inductor) |
- |
5500 |
|
- |
| 2.10.5.12(Wires in wound components) |
- |
5500 |
|
- |
| 2.10.5.13(Winding wire) |
- |
5500 |
|
- |
| 2.10.5.14(Additional insulation in wound components) |
- |
5500 |
|
- |
| 2.10.6(PCB material) |
- |
5500 |
|
- |
| 2.10.8.2(Thermal conditioning (thermal ageing)) |
- |
5500 |
|
- |
| 2.10.8.4(Abrasion resistance test) |
- |
5500 |
|
- |
| 2.10.9(Thermal Cycling) |
- |
5500 |
|
- |
| 2.10.10(Test for Pollution Degree 1 environment and for insulating compound) |
- |
5500 |
|
- |
| 2.10.11(Tests for semiconductor devices and for cemented joints) |
- |
5500 |
|
- |
| 2.10.12(Enclosed and sealed parts) |
- |
5500 |
|
- |
| 3.1.4(Internal wire) |
- |
5500 |
|
- |
| 3.2.4(Appliance inlet /connector) |
- |
5500 |
|
- |
| 3.2.5(Non re-wirable plug with PVC sheathed cable) |
- |
5500 |
|
- |
| 4.2.8(Cathode Ray Tubes) |
- |
5500 |
|
- |
| 4.3.8(Batteries) |
- |
5500 |
|
- |
| 4.3.10(Dust, powders, liquids and gases) |
- |
5500 |
|
- |
| 4.3.11(Containers for liquids or gases) |
- |
5500 |
|
- |
| 4.3.12(Flammable liquids) |
- |
5500 |
|
- |
| 4.3.13.2(Ionizing radiation) |
- |
5500 |
|
- |
| 4.3.13.3/ Annex Y(Effect of UV radiation on material/Ultraviolet conditioning test) |
- |
5500 |
|
- |
| 4.3.13.4(Human exposure to ultraviolet (UV) radiation) |
- |
5500 |
|
- |
| 4.3.13.5(LED, laser class) |
- |
5500 |
|
- |
| Annex A3(Hot flaming oil test) |
- |
5500 |
|
- |
| Annex U(Insulating winding wires for use without interleaved insulation) |
- |
5500 |
|
- |
| Annex CC(Evaluation of integrated circuit (IC) current limiters) |
- |
5500 |
|
- |
| Annex K(Thermal Control) |
- |
5500 |
|
- |
| Annex Q(Voltage Dependent Resistors) |
- |
5500 |
|
- |
| Annex B(Motor tests under abnormal conditions) |
- |
5500 |
|
- |
| Annex C(Transformers) |
- |
5500 |
|
- |
| Annex DD(Requirements for the mounting means of a rack mounted equipment) |
- |
5500 |
|
- |
| Annex EE(Household and home/ office document/ media shredders) |
- |
5500 |
|
- |
|
13 Nov, 2029 |
- Exclusion: Cl. 4.3.13.2 (Ionizing radiation), Cl. 4.3.13.3/ Annex Y (Effect of UV radiation on material/Ultraviolet conditioning test), Cl. 4.3.13.4 (Human exposure to ultraviolet (UV) radiation), Cl. 4.3.13.5 (LED, laser class), Cl. 1.5 (Components), Cl. 4.3.11 (Containers for liquids or gases), Cl. 4.2.8 (Cathode Ray Tubes) |
| 12737 |
BIS, Central Laboratory (CL)
| None
| IS 208 (2020) |
Door Handles - Specification ( Sixth Revision ) |
- |
Rs.2100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.2 (Tolerance) |
- |
|
|
|
| 5.1 (MANUFACTURE- General) |
- |
|
|
|
| 6.1 Table2A & 2B and Fig 1,2,3,4 (DIMENSIONS - Size 1. No. in each Lug 2. No. in a plate when a continious plate is used 3. Size Designation of Counter-sunk Head Wood Screws (as per IS 6760: 1972)) |
- |
|
|
|
| 6.1 Table2A & 2B and Fig 1,2,3,4 (DIMENSIONS - Size (A,B,C,D,E,F,G,H,I)) |
- |
|
|
|
| 4.2 -Table 1- viii (Ref. Cl 4.1, Table 1 of IS 742 : 1981) (Chemical composition - Zinc- IS 2600:1964) |
- |
|
|
|
| 4.2 -Table 1- viii (Ref. Cl 4.1, Table 1 of IS 742 : 1981) (Chemical composition - Impurities-Nickel- IS 2600:1964) |
- |
|
|
|
| 4.2 -Table 1- viii (Ref. Cl 4.1, Table 1 of IS 742 : 1981) (Chemical composition - Impurities-Thallium and Indium- IS 2600:1964) |
- |
|
|
|
| 4.2 -Table 1- viii (Ref. Cl 4.1, Table 1 of IS 742 : 1981) (Chemical composition - Impurities-Tin- IS 2600:1964) |
- |
|
|
|
| 4.2 -Table 1- viii (Ref. Cl 4.1, Table 1 of IS 742 : 1981) (Chemical composition - Impurities-Cadmium- IS 2600:1964) |
- |
|
|
|
|
- |
- Test facility is available for material test only as per Table 1. Grade of material as per Table 1 may please be declared. Sample dia > 3mm or thickness > 0.8 mm can only be tested, Sample size 5 pcs 5x5 cm.
Excluding Coating test; Cl.8.2 Corrosion Test & Cl.8.3 Anodizing Test |
| 12738 |
Arbro Pharmaceuticals Private Limited
| 8116816
| IS 17945 (2022) |
FOOD FOR SPECIAL MEDICAL PURPOSE INTENDED FOR INFANTS � SPECIFICATION |
- |
101500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Description - IS 17945) |
- |
0 |
|
NA |
| 5.4(Scorched Particles - IS 13500) |
- |
600 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Carotenes (Optional Parameter) - IS 17671 or ILL/STP/INST/050) |
- |
1800 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Amino acid (Optional Parameter)-AOAC 2018.06 or ILL/STP/INST/028) |
- |
12000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Non Protein Nitrogen(Optional Parameter)-ISO 8968-4) |
- |
600 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Nucleotides (Optional Parameter)-IS 16641 or ILL/STP/INST/051) |
- |
10000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(L-Carnitine (Optional Parameter)-IS 17668 or ILL/STP/INST/051) |
- |
3000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Lactalbumin (Optional Parameter) -Any validated International Method or ILL/STP/INST/051) |
- |
2000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Lactoferrin(Optional Parameter) - Any Validated International Method or ILL/STP/INST/051) |
- |
2000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Lysozyme (Optional Parameter)-ISO 27105 or ILL/STP/INST/050) |
- |
2000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Glucosamine (Optional Parameter) - Any Validated International Method or ILL/STP/INST/050) |
- |
2000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Inositol (Optional Parameter)- IS 16649 or any validated international method or ILL/STP/INST/047) |
- |
3000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Citric acid (Optional Parameter)-IS 12757 or ILL/STP/INST/037) |
- |
1800 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Cholesterol (Optional Parameter)-Any Validated International Method or ILL/STP/INST/025) |
- |
1000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Fucose (Optional Parameter)-Any Validated International Method or ILL/STP/INST/053) |
- |
1800 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Lipid phosphorous (Optional Parameter)-AOAC 923.07) |
- |
1000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Prostaglandins (Optional Parameter)-Any Validated International Method or ILL/STP/INST/051) |
- |
2000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Taurine (Optional Parameter)-AOAC 2018.06 or AOAC 997.05 or ILL/STP/INST/028) |
- |
3000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Molybdenum (Optional Parameter) - ISO 20649 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Chromium (Optional Parameter)-ISO 20649 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.11,Table 1(i)(Energy - IS 17945) |
- |
600 |
|
15% Discount |
| 5.11,Table 1(ii)(Total Protein - IS 7219) |
- |
550 |
|
15% Discount |
| 5.11,Table 1(iii)((a)Total Fat - IS 11721) |
- |
550 |
|
15% Discount |
| 5.11,Table 1(iii)((b)Linoleic acid -Annex B of IS 14433 or ISO 16958 or ILL/STP/INST/026) |
- |
400 |
|
15% Discount |
| 5.11,Table 1(iii)((c)alpha Linoleic acid Annex B of IS 14433 or ISO 16958 or ILL/STP/INST/026) |
- |
400 |
|
15% Discount |
| 5.11,Table 1(iv)(Docosahexaaenoic (DHA) - ISO 16958 or ILL/STP/INST/026) |
- |
1000 |
|
15% Discount |
| 5.11,Table 1(v)(Eicosapentaenoic acid (EPA) - IS 14433 or ISO or ILL/STP/INST/026) |
- |
1000 |
|
15% Discount |
| 5.11,Table 1(vi)(Arachidonic acid(ARA) ISO 16958 or ILL/STP/INST/026) |
- |
1000 |
|
15% Discount |
| 5.11,Table 1(vii)(Carbohydrate -Annex C of IS 1656) |
- |
400 |
|
15% Discount |
| 5.11,Table 1(viii)(Sodium-IS 12760 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.11,Table 1(ix)(Potassium - IS 12760 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.11,Table 1(x)(Calcium -IS 12760 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.11,Table 1(xi)(Phosphate - IS 12756 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.11,Table 1(xii)(Chloride - IS 11763 or AOAC 2013.03) |
- |
500 |
|
15% Discount |
| 5.11,Table 1(xiii)(Magnesium -IS 12760 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.11,Table 1(xiv)(Iron - ISO 15151 or ISO 21424 or AOAC 985.35 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.11,Table 1(xv)(Zinc- 15 of IS 1699 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.11,Table 1(xvi)(Copper - 15 of IS 1699 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.11,Table 1(xvii)(Selenium -IS 15303 or ISO 15151 or ISO 20649 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.11,Table 1(xviii)(Manganese - ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.11,Table 1(xix)(Iodine- IS 17379 or ILL/STP/INST/ICP/001) |
- |
800 |
|
- |
| 5.7, Table 1 (xx)(Chromium -ISO 20649 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.7, Table 1 (xxi)(Molybdenum - ISO 20649 or ILL/STP/INST/ICP/001) |
- |
500 |
|
- |
| 5.11,Table 1(xxii)(Thiamine - IS 17669 or ILL/STP/INST/013) |
- |
834 |
|
15% Discount |
| 5.11,Table 1(xxiii)(Riboflavin - IS 17669 or ILL/STP/INST/013) |
- |
834 |
|
15% Discount |
| 5.11,Table 1(xxiv)(Niacin Equivalent - IS17669 or ILL/STP/INST/013) |
- |
834 |
|
15% Discount |
| 5.11,Table 1(xxv)(Pantothenic acid - IS 16642 or ILL/STP/INST/014) |
- |
1800 |
|
15% Discount |
| 5.11,Table 1(xxvi)(Pyridoxine - IS17669 or ILL/STP/INST/013) |
- |
1800 |
|
15% Discount |
| 5.11,Table 1(xxvii)(Cobalamin - IS 16640 or AOAC 2014.02 or AOAC 2013.19 or ILL/STP/INST/013) |
- |
2500 |
|
15% Discount |
| 5.11,Table 1(xxviii)(Folic Acid - AOAC 2013.13 or ILL/STP/INST/013) |
- |
3500 |
|
15% Discount |
| 5.11,Table 1(xxix)(L-Ascorbic Acid (Vitamin C) - 5838 or IS 17176 or ILL/STP/INST/HPLC/022) |
- |
800 |
|
15% Discount |
| 5.11,Table 1(xxx)(Biotin - IS 17670 or ILL/STP/INST/015) |
- |
2500 |
|
15% Discount |
| 5.11,Table 1(xxxi)(Vitamin A (as retinol equivalent RE) -IS 16639 or ILL/STP/INST/011) |
- |
1800 |
|
15% Discount |
| 5.11,Table 1(xxxii)(Vitamin D - IS 17177 or ILL/STP/INST/012) |
- |
2500 |
|
15% Discount |
| 5.11,Table 1(xxxiii)(Vitamin E (as alpha tocopherol equivalent)only for type II - IS 16639 or ILL/STP/INST/011) |
- |
2500 |
|
15% Discount |
| 5.11,Table 1(xxxiv)(Vitamin K - IS 21446 or ILL/STP/INST/011) |
- |
2500 |
|
15% Discount |
| 5.11,Table 1(xxxv)(Choline - IS 17668 or ILL/STP/INST/016) |
- |
1800 |
|
15% Discount |
| 5.7, Table 1 (xxxvi)(Inositol- IS 16649 or ILL/STP/INST/047) |
- |
2200 |
|
15% Discount |
| "5.12 Table 2 (i) "(Aerobic plate count-IS 5402 (Part 1)) |
- |
500 |
|
15% Discount |
| "5.12 Table 2 (ii)"(Staphylococcuus aureus-IS 5887 (Part 8/Sec-1)) |
- |
500 |
|
15% Discount |
| "5.12 Table 2 (iii)"(Yeast & mould count-IS 5403) |
- |
500 |
|
15% Discount |
| "5.12 Table 2 (iv)"(Salmonella sp.-IS 5887 (Part 3)) |
- |
500 |
|
15% Discount |
| "5.12 Table 2 (v)"(Listeria monocytogenes-IS 14988 (Part 1)) |
- |
700 |
|
15% Discount |
| v(Bacillus cereus-IS 5887 (Part 6)) |
- |
500 |
|
15% Discount |
| "5.12 Table 2 (vii)"(Sulphite reducing clostridia-ISO 15213) |
- |
500 |
|
15% Discount |
| "5.12 Table 2 (viii)"(Enterobacteriacae-is 17112(p-1)) |
- |
500 |
|
15% Discount |
| "5.12 Table 2 (ix)"(Enterobacter Sakazakii(Cronobacter spp.)-ISO 22964) |
- |
500 |
|
15% Discount |
| 5.14(Lead - IS 12074 or AOAC 2015.01 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.14(Arsenic - IS 11124 or AOAC 2015.01 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.14(Tin - ISO 14377 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.14(Cadmium - 15 of IS 1699 or AOAC 2015.01 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.14(Melamine -IS 16195 or ILL/STP/INST/LC/007) |
- |
1800 |
|
15% Discount |
| 5.16 & 5.16.1.5(Optional Requirement for ECO MARK Vibrio cholerae & Vibrio parahaemolyticus IS 5887 Part-5) |
- |
500 |
|
15% Discount |
| 5.1(Description - IS 17945) |
- |
0 |
|
15% Discount |
| 5.4(Scorched Particles - IS 13500) |
- |
600 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Carotenes (Optional Parameter) - IS 17671 or ILL/STP/INST/050) |
- |
1800 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Amino acid (Optional Parameter)-AOAC 2018.06 or ILL/STP/INST/028) |
- |
12000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Non Protein Nitrogen(Optional Parameter)-ISO 8968-4) |
- |
600 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Nucleotides (Optional Parameter)-IS 16641 or ILL/STP/INST/051) |
- |
10000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(L-Carnitine (Optional Parameter)-IS 17668 or ILL/STP/INST/051) |
- |
3000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Lactalbumin (Optional Parameter) -Any validated International Method or ILL/STP/INST/051) |
- |
2000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Lactoferrin(Optional Parameter) - Any Validated International Method or ILL/STP/INST/051) |
- |
2000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Lysozyme (Optional Parameter)-ISO 27105 or ILL/STP/INST/050) |
- |
2000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Glucosamine (Optional Parameter) - Any Validated International Method or ILL/STP/INST/050) |
- |
2000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Inositol (Optional Parameter)- IS 16649 or any validated international method or ILL/STP/INST/047) |
- |
3000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Citric acid (Optional Parameter)-IS 12757 or ILL/STP/INST/037) |
- |
1800 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Cholesterol (Optional Parameter)-Any Validated International Method or ILL/STP/INST/025) |
- |
1000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Fucose (Optional Parameter)-Any Validated International Method or ILL/STP/INST/053) |
- |
1800 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Lipid phosphorous (Optional Parameter)-AOAC 923.07) |
- |
1000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Prostaglandins (Optional Parameter)-Any Validated International Method or ILL/STP/INST/051) |
- |
2000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Taurine (Optional Parameter)-AOAC 2018.06 or AOAC 997.05 or ILL/STP/INST/028) |
- |
3000 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Molybdenum (Optional Parameter) - ISO 20649 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| Clause 5.6 (as per details of table 1, clause 5.7 of IS 14433:2022)(Chromium (Optional Parameter)-ISO 20649 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.11,Table 1(i)(Energy - IS 17945) |
- |
600 |
|
15% Discount |
| 5.11,Table 1(ii)(Total Protein - IS 7219) |
- |
550 |
|
15% Discount |
| 5.11,Table 1(iii)((a)Total Fat - IS 11721) |
- |
550 |
|
15% Discount |
| 5.11,Table 1(iii)((b)Linoleic acid -Annex B of IS 14433 or ISO 16958 or ILL/STP/INST/026) |
- |
400 |
|
15% Discount |
| 5.11,Table 1(iii)((c)alpha Linoleic acid Annex B of IS 14433 or ISO 16958 or ILL/STP/INST/026) |
- |
400 |
|
15% Discount |
| 5.11,Table 1(iv)(Docosahexaaenoic (DHA) - ISO 16958 or ILL/STP/INST/026) |
- |
1000 |
|
15% Discount |
| 5.11,Table 1(v)(Eicosapentaenoic acid (EPA) - IS 14433 or ISO or ILL/STP/INST/026) |
- |
1000 |
|
15% Discount |
| 5.11,Table 1(vi)(Arachidonic acid(ARA) ISO 16958 or ILL/STP/INST/026) |
- |
1000 |
|
15% Discount |
| 5.11,Table 1(vii)(Carbohydrate -Annex C of IS 1656) |
- |
400 |
|
15% Discount |
| 5.11,Table 1(viii)(Sodium-IS 12760 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.11,Table 1(ix)(Potassium - IS 12760 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.11,Table 1(x)(Calcium -IS 12760 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.11,Table 1(xi)(Phosphate - IS 12756 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.11,Table 1(xii)(Chloride - IS 11763 or AOAC 2013.03) |
- |
500 |
|
15% Discount |
| 5.11,Table 1(xiii)(Magnesium -IS 12760 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.11,Table 1(xiv)(Iron - ISO 15151 or ISO 21424 or AOAC 985.35 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.11,Table 1(xv)(Zinc- 15 of IS 1699 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.11,Table 1(xvi)(Copper - 15 of IS 1699 or ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.11,Table 1(xvii)(Selenium -IS 15303 or ISO 15151 or ISO 20649 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.11,Table 1(xviii)(Manganese - ISO 15151 or ISO 21424 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.11,Table 1(xix)(Iodine- IS 17379 or ILL/STP/INST/ICP/001) |
- |
800 |
|
15% Discount |
| 5.7, Table 1 (xx)(Chromium -ISO 20649 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.7, Table 1 (xxi)(Molybdenum - ISO 20649 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.11,Table 1(xxii)(Thiamine - IS 17669 or ILL/STP/INST/013) |
- |
834 |
|
15% Discount |
| 5.11,Table 1(xxiii)(Riboflavin - IS 17669 or ILL/STP/INST/013) |
- |
834 |
|
15% Discount |
| 5.11,Table 1(xxiv)(Niacin Equivalent - IS17669 or ILL/STP/INST/013) |
- |
834 |
|
15% Discount |
| 5.11,Table 1(xxv)(Pantothenic acid - IS 16642 or ILL/STP/INST/014) |
- |
1800 |
|
15% Discount |
| 5.11,Table 1(xxvi)(Pyridoxine - IS17669 or ILL/STP/INST/013) |
- |
1800 |
|
15% Discount |
| 5.11,Table 1(xxvii)(Cobalamin - IS 16640 or AOAC 2014.02 or AOAC 2013.19 or ILL/STP/INST/013) |
- |
2500 |
|
15% Discount |
| 5.11,Table 1(xxviii)(Folic Acid - AOAC 2013.13 or ILL/STP/INST/013) |
- |
3500 |
|
15% Discount |
| 5.11,Table 1(xxix)(L-Ascorbic Acid (Vitamin C) - 5838 or IS 17176 or ILL/STP/INST/HPLC/022) |
- |
800 |
|
15% Discount |
| 5.11,Table 1(xxx)(Biotin - IS 17670 or ILL/STP/INST/015) |
- |
2500 |
|
15% Discount |
| 5.11,Table 1(xxxi)(Vitamin A (as retinol equivalent RE) -IS 16639 or ILL/STP/INST/011) |
- |
1800 |
|
15% Discount |
| 5.11,Table 1(xxxii)(Vitamin D - IS 17177 or ILL/STP/INST/012) |
- |
2500 |
|
15% Discount |
| 5.11,Table 1(xxxiii)(Vitamin E (as alpha tocopherol equivalent)only for type II - IS 16639 or ILL/STP/INST/011) |
- |
2500 |
|
15% Discount |
| 5.11,Table 1(xxxiv)(Vitamin K - IS 21446 or ILL/STP/INST/011) |
- |
2500 |
|
15% Discount |
| 5.11,Table 1(xxxv)(Choline - IS 17668 or ILL/STP/INST/016) |
- |
1800 |
|
15% Discount |
| 5.7, Table 1 (xxxvi)(Inositol- IS 16649 or ILL/STP/INST/047) |
- |
2200 |
|
15% Discount |
| "5.12 Table 2 (i) "(Aerobic plate count-IS 5402 (Part 1)) |
- |
500 |
|
15% Discount |
| "5.12 Table 2 (ii)"(Staphylococcuus aureus-IS 5887 (Part 8/Sec-1)) |
- |
500 |
|
15% Discount |
| "5.12 Table 2 (iii)"(Yeast & mould count-IS 5403) |
- |
500 |
|
15% Discount |
| "5.12 Table 2 (iv)"(Salmonella sp.-IS 5887 (Part 3)) |
- |
500 |
|
15% Discount |
| "5.12 Table 2 (v)"(Listeria monocytogenes-IS 14988 (Part 1)) |
- |
700 |
|
15% Discount |
| v(Bacillus cereus-IS 5887 (Part 6)) |
- |
500 |
|
15% Discount |
| "5.12 Table 2 (vii)"(Sulphite reducing clostridia-ISO 15213) |
- |
500 |
|
15% Discount |
| "5.12 Table 2 (viii)"(Enterobacteriacae-is 17112(p-1)) |
- |
500 |
|
15% Discount |
| "5.12 Table 2 (ix)"(Enterobacter Sakazakii(Cronobacter spp.)-ISO 22964) |
- |
500 |
|
15% Discount |
| 5.14(Lead - IS 12074 or AOAC 2015.01 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.14(Arsenic - IS 11124 or AOAC 2015.01 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.14(Tin - ISO 14377 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.14(Cadmium - 15 of IS 1699 or AOAC 2015.01 or ILL/STP/INST/ICP/001) |
- |
500 |
|
15% Discount |
| 5.14(Melamine -IS 16195 or ILL/STP/INST/LC/007) |
- |
2500 |
|
15% Discount |
| 5.16 & 5.16.1.5(Optional Requirement for ECO MARK Vibrio cholerae & Vibrio parahaemolyticus IS 5887 Part-5) |
- |
1000 |
|
15% Discount |
|
14 Jan, 2029 |
- Included w.e.f. 07.12.2023 |
| 12739 |
DELHI TEST HOUSE (A Unit of Delhii Test House Global LLP), Azadpur
| 8131406
| IS 14333 (2022) |
Polyethylene Pipes for Sewerage and Industrial Chemicals and Effluent � Specification (First Revision) |
- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2.1,T2("Base Density
(At 27°C Temp.)-IS 7328:2020 ") |
- |
1000 |
|
- |
| 5.2.1,T2(Melt Flow Rate (At 190°C /5kg)-IS 2530:1963) |
- |
1000 |
|
- |
| 5.2.1,T2(Thermal Stability(Oxidation Induction Time)-IS 4984:2016(Annexure-B)) |
- |
1000 |
|
- |
| 5.2.1,T2("Volatile Matter- IS 4984:2016
(Annexure-C)") |
- |
1000 |
|
- |
| 5.2.1,T2("Water Content-IS 4984:2016
(Annexure-D)") |
- |
1000 |
|
- |
| 5.3(Loading of Carbon Black - IS 2530:1963) |
- |
500 |
|
- |
| 5.3(Ash content- Any Method) |
- |
1000 |
|
- |
| 5.4(Antioxidant - Any Method) |
- |
1000 |
|
- |
| 6.2(Colour- IS 14333-2022) |
- |
200 |
|
- |
| 7.1(Visual Appearance- IS 14333-2022) |
- |
200 |
|
- |
| 7.2(Length- IS 14333-2022) |
- |
100 |
|
- |
| 7.4,T3 of IS 4984(Outside Diameter-IS 4984-2016) |
- |
200 |
|
- |
| 7.4,T4 of IS 4984(wall Thickness-IS 4984-2016) |
- |
200 |
|
- |
| 7.4,T3 of IS 4984(Ovality-IS 4984-2016) |
- |
200 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 27 oC , Test Period - 100 hrs.-IS 4984-2016 (Annexure-E)) |
- |
1500 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
1000 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 165 hrs.-IS 4984-2016 (Annexure-E)) |
- |
3000 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 1000 hrs.-IS 4984-2016 (Annexure-E)) |
- |
10000 |
|
- |
| 8.2("Longitudinal Reversion Test - IS 4984-2016
(Annexure-F)") |
- |
1000 |
|
- |
| 8.3(Carbon black content Dispersion- IS 2530-1963) |
- |
1000 |
|
- |
| 8.4(Melt Flow rate(Temperature - 190oC,Mass 5kg)-IS 2530-1963) |
- |
1000 |
|
- |
| 8.6(Density-IS 7328:2020) |
- |
1000 |
|
- |
| 8.7("Tensile Strength for Butt Fusion - IS 4984-2016
(Annexure-G)") |
- |
1500 |
|
- |
| 8.9(Slow Crack Growth Rate{Internal Pressure creep Rupture test, Temperature - 80±1 oC , Test Pressure – 0.80MPa, Test Period - 500 hrs.-IS 4984-2016 (Annexure-E &J)) |
- |
4000 |
|
- |
| 8.8,T5("Tensile - IS 4984-2016
(Annexure-H)") |
- |
1000 |
|
- |
| 8.8,T5("Elongation -IS 4984-2016
(Annexure-H)") |
- |
500 |
|
- |
| 8.5(Oxidation Induction Time -IS 4984:2016(Annexure-B)) |
- |
2000 |
|
- |
| 5.2.1,T2("Base Density
(At 27°C Temp.)-IS 7328:2020 ") |
- |
1000 |
|
- |
| 5.2.1,T2(Melt Flow Rate (At 190°C /5kg)-IS 2530:1963) |
- |
1000 |
|
- |
| 5.2.1,T2(Thermal Stability(Oxidation Induction Time)-IS 4984:2016(Annexure-B)) |
- |
1000 |
|
- |
| 5.2.1,T2("Volatile Matter- IS 4984:2016
(Annexure-C)") |
- |
1000 |
|
- |
| 5.2.1,T2("Water Content-IS 4984:2016
(Annexure-D)") |
- |
1000 |
|
- |
| 5.3(Loading of Carbon Black - IS 2530:1963) |
- |
1000 |
|
- |
| 5.3(Ash content- Any Method) |
- |
1000 |
|
- |
| 5.4(Antioxidant - Any Method) |
- |
2000 |
|
- |
| 6.2(Colour- IS 14333-2022) |
- |
200 |
|
- |
| 7.1(Visual Appearance- IS 14333-2022) |
- |
200 |
|
- |
| 7.2(Length- IS 14333-2022) |
- |
100 |
|
- |
| 7.4,T3 of IS 4984(Outside Diameter-IS 4984-2016) |
- |
500 |
|
- |
| 7.4,T4 of IS 4984(wall Thickness-IS 4984-2016) |
- |
100 |
|
- |
| 7.4,T3 of IS 4984(Ovality-IS 4984-2016) |
- |
100 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 27 oC , Test Period - 100 hrs.-IS 4984-2016 (Annexure-E)) |
- |
1000 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
1500 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 165 hrs.-IS 4984-2016 (Annexure-E)) |
- |
3000 |
|
- |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 1000 hrs.-IS 4984-2016 (Annexure-E)) |
- |
3000 |
|
- |
| 8.2("Longitudinal Reversion Test - IS 4984-2016
(Annexure-F)") |
- |
1000 |
|
- |
| 8.3(Carbon black content Dispersion- IS 2530-1963) |
- |
1000 |
|
- |
| 8.4(Melt Flow rate(Temperature - 190oC,Mass 5kg)-IS 2530-1963) |
- |
1000 |
|
- |
| 8.6(Density-IS 7328:2020) |
- |
1000 |
|
- |
| 8.7("Tensile Strength for Butt Fusion - IS 4984-2016
(Annexure-G)") |
- |
1100 |
|
- |
| 8.9(Slow Crack Growth Rate{Internal Pressure creep Rupture test, Temperature - 80±1 oC , Test Pressure – 0.80MPa, Test Period - 500 hrs.-IS 4984-2016 (Annexure-E &J)) |
- |
3500 |
|
- |
| 8.8,T5("Tensile - IS 4984-2016
(Annexure-H)") |
- |
1100 |
|
- |
| 8.8,T5("Elongation -IS 4984-2016
(Annexure-H)") |
- |
500 |
|
- |
| 8.5(Oxidation Induction Time -IS 4984:2016(Annexure-B)) |
- |
2000 |
|
- |
|
17 Jun, 2027 |
- Revised Version of IS 14333:2022. Included w.e.f. 24.03.2023 |
| 12740 |
Arbro Pharmaceuticals Private Limited
| 8116816
| IS 16240 (2015) |
Reverse osmosis (RO) based point-of-use (POU) water treatment system - Specification |
- |
87200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.3.1(TDS Reduction (IS 3025 Part 16)) |
- |
1200 |
|
300 RS PER ANALYSIS FOR 4 TIME TESTING
(15% DISCOUNT) |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Arsenic (IS 025 Part 37)) |
- |
2000 |
|
500 RS PER ANALYSIS FOR 4 TIME TESTING
(15% DISCOUNT) |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Cadmium (IS 025 Part 41)) |
- |
2000 |
|
500 RS PER ANALYSIS FOR 4 TIME TESTING
(15% DISCOUNT) |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Chromium (IS 025 Part 52)) |
- |
2000 |
|
500 RS PER ANALYSIS FOR 4 TIME TESTING
(15% DISCOUNT) |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Copper (IS 025 Part 42)) |
- |
2000 |
|
500 RS PER ANALYSIS FOR 4 TIME TESTING
(15% DISCOUNT) |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Fluoride (IS 025 Part 60)) |
- |
2000 |
|
500 RS PER ANALYSIS FOR 4 TIME TESTING
(15% DISCOUNT) |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Lead (IS 025 Part 47)) |
- |
2000 |
|
500 RS PER ANALYSIS FOR 4 TIME TESTING
(15% DISCOUNT) |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Mercury (IS 025 Part 48)) |
- |
2000 |
|
500 RS PER ANALYSIS FOR 4 TIME TESTING
(15% DISCOUNT) |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Nitrate (IS 025 Part 34)) |
- |
4000 |
|
1000 RS PER ANALYSIS FOR 4 TIME TESTING
(15% DISCOUNT) |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Iron (IS 025 Part 53)) |
- |
2000 |
|
500 RS PER ANALYSIS FOR 4 TIME TESTING
(15% DISCOUNT) |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Pesticides Total (IS 10500)) |
- |
24000 |
|
6000 RS PER ANALYSIS FOR 4 TIME TESTING
(15% DISCOUNT) |
| Table 1 Cl.6.3.3 and Cl.6.3.4(E.coli (IS 10500)) |
- |
60000 |
|
15000 RS PER ANALYSIS FOR 4 TIME TESTING (ALL MICRO PARAMETER PRICE 60000 FOR 4 TIMES TESTING)
(15% DISCOUNT) |
| Table 1 Cl.6.3.3 and Cl.6.3.4(MS2 (IS 10500)) |
- |
60000 |
|
15000 RS PER ANALYSIS FOR 4 TIMES TESTING (ALL MICRO PARAMETER PRICE 60000 FOR 4 TIMES TESTING)
(15% DISCOUNT) |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Cryptosporidium (IS 10500)) |
- |
60000 |
|
15000 RS PER ANALYSIS FOR 4 TIME TESTING (ALL MICRO PARAMETER PRICE 60000 FOR 4 TIMES TESTING)
(15% DISCOUNT) |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Giardia lamblia (IS 10500)) |
- |
60000 |
|
15000 RS PER ANALYSIS FOR 4 TIME TESTING (ALL MICRO PARAMETER PRICE 60000 RS FOR 4 TIMES TESTING)
(15% DISCOUNT) |
| 6.3.1(TDS Reduction (IS 3025 Part 16)) |
- |
- |
|
- |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Arsenic (IS 025 Part 37)) |
- |
- |
|
- |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Cadmium (IS 025 Part 41)) |
- |
- |
|
- |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Chromium (IS 025 Part 52)) |
- |
- |
|
- |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Copper (IS 025 Part 42)) |
- |
- |
|
- |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Fluoride (IS 025 Part 60)) |
- |
- |
|
- |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Lead (IS 025 Part 47)) |
- |
- |
|
- |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Mercury (IS 025 Part 48)) |
- |
- |
|
- |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Nitrate (IS 025 Part 34)) |
- |
- |
|
- |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Iron (IS 025 Part 53)) |
- |
- |
|
- |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Pesticides Total (IS 10500)) |
- |
- |
|
- |
| Table 1 Cl.6.3.3 and Cl.6.3.4(E.coli (IS 10500)) |
- |
- |
|
- |
| Table 1 Cl.6.3.3 and Cl.6.3.4(MS2 (IS 10500)) |
- |
- |
|
- |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Cryptosporidium (IS 10500)) |
- |
- |
|
- |
| Table 1 Cl.6.3.3 and Cl.6.3.4(Giardia lamblia (IS 10500)) |
- |
- |
|
- |
|
14 Jan, 2029 |
- Included w.e.f. 30.01.2023.
Exclusion: Overall migration limit (Cl.5.1), Pneumatic test (Cl.7), Hydrostatic test (Cl.6.7), Electrical safety (Cl.6.5) & Table 1 (xiii) Cryptosporidium Parvum and (xiv) Giardia lamblia. |
| 12741 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 2080 (2021) |
Specification for stabilized hydrogen peroxide First Revision |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Description - IS 2080:2021) |
- |
|
|
|
| 4.2 (Strength - IS 2080:2021) |
- |
|
|
|
| 4.4/Table 1 (i) (Acidity (as H2SO4) - IS 2080:2021) |
- |
|
|
|
| 4.4/Table 1 (ii) (Residue on Evaporation - IS 2080:2021) |
- |
|
|
|
| 4.4/Table 1 (iv) (Iron (as Fe) - IS 2080:2021) |
- |
|
|
|
| 4.4/Table 1 (v) (Copper (as Cu) - IS 2080:2021) |
- |
|
|
|
| 4.4/Table 1 (vi) (Lead (as Pb) - IS 2080:2021) |
- |
|
|
|
| 4.4/Table 1 (vii) (Arsenic (as As2O3) - IS 2080:2021) |
- |
|
|
|
| 4.4/Table 1 (iii) (Residue on Ignition - IS 2080:2021) |
- |
|
|
|
|
- |
- - |
| 12742 |
Bharat Test House Pvt. Ltd. 1668 Sonipat
| 9168306
| IS 2494 : Part 1 (1994) |
V - Belts - Endless V - Belts for industrial purposes: Part 1 general purpose - Specification (Second Revision) |
- |
4250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 11.0(Marking) |
- |
250 |
|
- |
| 10.1(Elongation) |
- |
875 |
|
- |
| 10.1(Tensile Strength) |
- |
875 |
|
- |
| 7.2.2(Matched Belts - Code) |
- |
250 |
|
- |
| 7.1(Belt Pitch Length) |
- |
500 |
|
- |
| 6.0(Designation) |
- |
250 |
|
- |
| 5 Table 2B(Cross sectional dimension) |
- |
100 |
|
- |
| 5 Table 2A(Cross sectional dimension) |
- |
100 |
|
- |
| 5 Table 1(Cross sectional dimension) |
- |
100 |
|
- |
| 4.1(Material and Workmanship) |
- |
250 |
|
- |
| 7.2(Test Matched Belts) |
- |
250 |
|
- |
| Clause 5 Table 1(Nominal Pitch Width (Wp)) |
- |
100 |
|
- |
| Clause 5 Table 1(Nominal Height (T)) |
- |
100 |
|
- |
| Clause 5 Table 1(Nominal Pitch Width (W)) |
- |
100 |
|
- |
| Clause 5 Table 1(Nominal Included Angle (A)) |
- |
150 |
|
- |
|
26 Jul, 2027 |
- - |
| 12743 |
AADCO TESTING & RESEARCH LABORATORY PVT LTD (F28), GHAZIABAD
| 8141606
| IS 383 (2016) |
Coarse and Fine Aggregate for Concrete - Specification (Third Revision) |
All Sizes |
6000 View breakup
Rs.6000/- for Mechanical
(10% discount to BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1-Table 7(i)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 80 mm sieve ) |
- |
100 |
|
- |
| 6.1-Table 7(ii)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 63 mm sieve ) |
- |
100 |
|
- |
| 6.1-Table 7(iii)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 40 mm sieve ) |
- |
100 |
|
- |
| 6.1-Table 7(iv)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 20 mm sieve ) |
- |
100 |
|
- |
| 6.1-Table 7(v)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 16 mm sieve ) |
- |
100 |
|
- |
| 6.2-Table 7(vi)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 12.5 mm sieve) |
- |
100 |
|
- |
| 6.1-Table 7(vii)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 10 mm sieve ) |
- |
100 |
|
- |
| 6.1-Table 7(viii)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 4.75 mm sieve ) |
- |
100 |
|
- |
| 6.1-Table 7(ix)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 2.36 mm sieve ) |
- |
100 |
|
- |
| 6.2-Table 7(i)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 80 mm sieve) |
- |
100 |
|
- |
| 6.2-Table 7(ii)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 63 mm sieve) |
- |
100 |
|
- |
| 6.2-Table 7(iii)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 40 mm sieve) |
- |
100 |
|
- |
| 6.2-Table 7(iv)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 20 mm sieve) |
- |
100 |
|
- |
| 6.2-Table 7(v)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 16 mm sieve) |
- |
100 |
|
- |
| 6.2-Table 7(vii)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 10 mm sieve) |
- |
100 |
|
- |
| 6.2-Table 7(viii)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 4.75 mm sieve) |
- |
100 |
|
- |
| 6.2-Table 7(ix)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 2.36 mm sieve) |
- |
100 |
|
- |
| 6.3-Table 9(i)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 10mm Sieve ) |
- |
100 |
|
- |
| 6.3-Table 9(ii)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 4.75mm Sieve ) |
- |
100 |
|
- |
| 6.3-Table 9(iii)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 2.36mm Sieve ) |
- |
100 |
|
- |
| 6.3-Table 9(iv)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 1.18mm Sieve ) |
- |
100 |
|
- |
| 6.3-Table 9(v)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 600µm Sieve ) |
- |
100 |
|
- |
| 6.3-Table 9(vi)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 300µm Sieve ) |
- |
100 |
|
- |
| 6.3-Table 9(vii)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 150µm Sieve ) |
- |
100 |
|
- |
| 6.4-Table 10(i)(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Percentage Passing through 80mm Sieve ) |
- |
100 |
|
- |
| 6.4-Table 10(ii)(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Percentage Passing through 40mm Sieve ) |
- |
100 |
|
- |
| 6.4-Table 10(iii)(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Percentage Passing through 20mm Sieve ) |
- |
100 |
|
- |
| 6.4-Table 10(iv)(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Percentage Passing through 4.75mm Sieve ) |
- |
100 |
|
- |
| 6.4-Table 10(v)(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Percentage Passing through 600µm Sieve ) |
- |
100 |
|
- |
| 6.4-Table 10(vi)(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Percentage Passing through 150µm Sieve ) |
- |
100 |
|
- |
| 5.4.1 (a)(mechanical properties- Aggregate Crushing Value/Ten Percent Fines Value) |
- |
2000 |
|
- |
| 5.4.1 (b)(mechanical properties- Aggregate Crushing Value/Ten Percent Fines Value) |
- |
2000 |
|
- |
| 5.4.2(a)(Â Â Aggregates Impact Value) |
- |
1000 |
|
- |
| 5.4.2(b)(Â Â Aggregates Impact Value) |
- |
1000 |
|
- |
| 5.4.3(a)( Aggregate Abrasion Value) |
- |
1000 |
|
- |
| 5.4.3(b)( Aggregate Abrasion Value) |
- |
1000 |
|
- |
| 5.5-IS: 2386 (P-5)(Soundness (coarse aggregate)) |
- |
1000 |
|
- |
| 5.5-IS: 2386 (P-5)(Soundness (fine aggregate)) |
- |
1000 |
|
- |
| 5.6-IS: 2386 (P-7)(Alkali Aggregate Reaction (fine aggregate)) |
- |
1000 |
|
- |
| 5.6-IS: 2386 (P-7)(Alkali Aggregate Reaction (coarse aggregate)) |
- |
1000 |
|
- |
|
26 Jul, 2027 |
- Exclusion: Petrography (cl.5.2.1, Table-2 & Note-2) |
| 12744 |
National Test House (NTH), Alipore, Kolkata-700027
| 5123904
| IS 6419 (1996) |
Welding rods and bare electrodes for gas shielded arc welding of structural steel - Specification (First Revision) |
- |
18500 View breakup
Chemical Test of Wire/Weld Rs. 5,000/- each
Mechanical Test Rs. Rs.15,000/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Diameter) |
- |
500 |
|
- |
| 6(Reels for Wire) |
- |
500 |
|
- |
| 7(Reeling Condition) |
- |
500 |
|
- |
| 8(Dimension of Spools, Rims & Coils) |
- |
500 |
|
- |
| 9(Lengthof Rods) |
- |
500 |
|
- |
| 10.1(Finish) |
- |
500 |
|
- |
| 10.2.1 Table 5(Tensile Strength-IS 1608(P-1)) |
- |
1000 |
|
- |
| 10.2.2 Table 6(Cast- As per Cl.10.2.2 ) |
- |
500 |
|
- |
| 10.2.3 Table 6(Helix- As per Cl.10.2.3 ) |
- |
500 |
|
- |
| 14.1 Table 7(Carbon-Relevant parts of IS 228) |
- |
500 |
|
- |
| 14.1 Table 7(Manganese-Relevant parts of IS 228) |
- |
500 |
|
- |
| 14.1 Table 7(Silicon-Relevant parts of IS 228) |
- |
500 |
|
- |
| 14.1 Table 7(Phosphorous-Relevant parts of IS 228) |
- |
500 |
|
- |
| 14.1 Table 7(Sulphur-Relevant parts of IS 228) |
- |
500 |
|
- |
| 14.1 Table 7(Nickel-Relevant parts of IS 228) |
- |
500 |
|
- |
| 14.1 Table 7(Chromium-Relevant parts of IS 228) |
- |
500 |
|
- |
| 14.1 Table 7(Molybdenum-Relevant parts of IS 228) |
- |
500 |
|
- |
| 14.1 Table 7(Vanadium-Relevant parts of IS 228) |
- |
500 |
|
- |
| 14.1 Table 7(Copper-Relevant parts of IS 228) |
- |
500 |
|
- |
| 14.1 Table 7(Mo+Ni+Cr-Relevant parts of IS 228) |
- |
500 |
|
- |
| 10.2.1(Welding rods and bare electrodes for gas shielded arc welding of structural steel) |
- |
1000 |
|
- |
| 14.2(Soundness test) |
- |
1000 |
|
- |
| 14.3.2(UTS) |
- |
1000 |
|
- |
| 14.3.2(Yield Stress) |
- |
1000 |
|
- |
| 14.3.2(% of Elongation) |
- |
1000 |
|
- |
| 14.3.3(Impact Test) |
- |
3000 |
|
- |
| 5(Diameter) |
- |
- |
|
- |
| 6(Reels for Wire) |
- |
- |
|
- |
| 7(Reeling Condition) |
- |
- |
|
- |
| 8(Dimension of Spools, Rims & Coils) |
- |
- |
|
- |
| 9(Lengthof Rods) |
- |
- |
|
- |
| 10.1(Finish) |
- |
- |
|
- |
| 10.2.1 Table 5(Tensile Strength-IS 1608(P-1)) |
- |
- |
|
- |
| 10.2.2 Table 6(Cast- As per Cl.10.2.2 ) |
- |
- |
|
- |
| 10.2.3 Table 6(Helix- As per Cl.10.2.3 ) |
- |
- |
|
- |
| 14.1 Table 7(Carbon-Relevant parts of IS 228) |
- |
- |
|
- |
| 14.1 Table 7(Manganese-Relevant parts of IS 228) |
- |
- |
|
- |
| 14.1 Table 7(Silicon-Relevant parts of IS 228) |
- |
- |
|
- |
| 14.1 Table 7(Phosphorous-Relevant parts of IS 228) |
- |
- |
|
- |
| 14.1 Table 7(Sulphur-Relevant parts of IS 228) |
- |
- |
|
- |
| 14.1 Table 7(Nickel-Relevant parts of IS 228) |
- |
- |
|
- |
| 14.1 Table 7(Chromium-Relevant parts of IS 228) |
- |
- |
|
- |
| 14.1 Table 7(Molybdenum-Relevant parts of IS 228) |
- |
- |
|
- |
| 14.1 Table 7(Vanadium-Relevant parts of IS 228) |
- |
- |
|
- |
| 14.1 Table 7(Copper-Relevant parts of IS 228) |
- |
- |
|
- |
| 14.1 Table 7(Mo+Ni+Cr-Relevant parts of IS 228) |
- |
- |
|
- |
| 10.2.1(Welding rods and bare electrodes for gas shielded arc welding of structural steel) |
- |
- |
|
- |
| 14.2(Soundness test) |
- |
- |
|
- |
| 14.3.2(UTS) |
- |
- |
|
- |
| 14.3.2(Yield Stress) |
- |
- |
|
- |
| 14.3.2(% of Elongation) |
- |
- |
|
- |
| 14.3.3(Impact Test) |
- |
- |
|
- |
|
08 Apr, 2027 |
- Included w.e.f. 04.01.2024 |
| 12745 |
BIS, Guwahati Branch Laboratory (GBL)
| None
| IS 2202 : Part 1 (2023) |
WOODEN FLUSH DOOR SHUTTERS SOLID CORE TYPE SPECIFICATION PART 1 PLYWOOD FACE PANELS Seventh Revision |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.1 (Workmanship & Finish) |
- |
|
|
|
| 9.2 (Workmanship & Finish) |
- |
|
|
|
| 9.3 (Workmanship & Finish) |
- |
|
|
|
| 11.1 (Dimensions - Height) |
- |
|
|
|
| 11.1 (Dimensions - Width) |
- |
|
|
|
| 11.1 (Dimensions - Thickness) |
- |
|
|
|
| 11.1 (Dimensions - Variation in thickness) |
- |
|
|
|
| 11.1 (Dimensions - Squareness) |
- |
|
|
|
| 11.12 (End immersion test) |
- |
|
|
|
| 11.13 (Knife Test) |
- |
|
|
|
| 11.14 (Glue Adhesion Test) |
- |
|
|
|
|
- |
- i) Qty. required 1 Nos.
ii) Except "Cl-11.4 (Impact Indentation Test),
Cl-11.5 (Flexure Test),
Cl-11.6 (Edge Loading Test),
Cl-11.7 (Shock Resistance Test),
Cl-11.8 (Buckling Resistance Test),
Cl-11.9 (Slamming Test),
Cl-11.10 (Misuse Test)" |
| 12746 |
LABORATORY, TEXTILES COMMITTEE, MUMBAI
| 7149904
| IS 1 (1968) |
Specification for the national flag of India (Cotton khadi) (second revision) |
- |
15900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2.2
Table 3 i)
IS 1963(Ends/dm) |
- |
100 |
|
Excluding GST |
| 3.2.2
Table 3 ii)
IS 1963(Picks/dm) |
- |
100 |
|
Excluding GST |
| 3.1.2.3
Table 2 iii)
IS 2977( Dimensional changes) |
- |
300 |
|
Excluding GST |
| 3.1.2
Table 1 iii)
IS 1964(Weight) |
- |
200 |
|
Excluding GST |
| 3.1.2.3
Table 2 i)b
IS 765(Washing) |
- |
400 |
|
Excluding GST |
| 3.1.2.3
Table 2 i)a
IS 686/IS 2454(The colour fastness ratings and other requirements of hunting are given in Table 2:
Colour fastness to :
l.ight) |
- |
3000 |
|
Excluding GST |
| 3.1.2.3
Table 2 ii)
Cold Method of IS 1390(pH Value) |
- |
300 |
|
Excluding GST |
| 5,5.1 b(The number of stitches shall not be less than
4 per cm) |
- |
200 |
|
Excluding GST |
| 3.1
3.1.1(Cotton Khadi Bunting :
Yarn -“The yarn used for the manufacture of bunting shall be hand_ spun from clean-carded cotton. The approximate count of yarn for warp and weft shall he 30 tex x 2 (or Nm 33/2 ).) |
- |
200 |
|
Excluding GST |
| 3.1.2
Table 1 iv)b
IS 1969(Weft) |
- |
550 |
|
Excluding GST |
| 3.2
3.2.1(Cotton Khadi Duck :- used for the sleeve of the flag.
Yarn -The yarn used in the manufacture of duck shall be handspun from clean carded cotton. The approximate count of yarn for warpand weft shall be 38 tex x 3 (or Nm 26/3).) |
- |
200 |
|
Excluding GST |
| 3.1.2
Table 1 iv)a
IS 1969( Breaking load on 50 x 200 mm strips:
Wrap) |
- |
550 |
|
Excluding GST |
|
3.2.2
Table 3 (REQUIREMENTS OF COTTON KHADI DUCK :-) |
- |
950 |
|
Excluding GST |
| 3.4
3.4.1,Table 4 i)(Hemp Cordage
The cordages of various sizes shall conform to the requirements
given in Table 4.
Size ) |
- |
1700 |
|
Excluding GST |
| 3.5,3.5.1(Wooden Toggles) |
- |
375 |
|
Excluding GST |
| 4,4.1
Table 5
Fig. 2 & 3(Dimensions of
Flag
) |
- |
375 |
|
Excluding GST |
| 4.3.1
Table 6
Fig. 4.(Dimensions of the Asoka Chakra ) |
- |
300 |
|
Excluding GST |
| 3.1.2
Table 1 i)
IS 1963(Ends/dm) |
- |
100 |
|
Excluding GST |
| 3.1.2
Table 1 ii)
IS 1963(Picks/dm) |
- |
100 |
|
Excluding GST |
| 3.1.2
Table 1 iv)b
IS 1969(Weft) |
- |
550 |
|
Excluding GST |
| 3.2.2
Table 3 iii)
IS 1964(Weight) |
- |
200 |
|
Excluding GST |
| 3.2.2
Table 3 iv)a
IS 1969( Breaking load on 50 x 200 mm strips:
Wrap) |
- |
550 |
|
Excluding GST |
| 3.2.2
Table 3 iv)b
IS 1969(Weft) |
- |
550 |
|
Excluding GST |
| 3.3,3.3.1
IS 1720(Sewing Threads
) |
- |
800 |
|
Excluding GST |
| 3.3,3.3.2
IS 1720(Sewing Threads) |
- |
800 |
|
Excluding GST |
| 3.4
3.4.1,Table 4 ii)(No of Strands) |
- |
200 |
|
Excluding GST |
| 3.4
3.4.1,Table 4 iii)(Linear Density) |
- |
250 |
|
Excluding GST |
| 3.4
3.4.1,Table 4 iv)
Appendix A.(Breaking load) |
- |
1250 |
|
Excluding GST |
| 3.5.2
Table 5
Fig.1(Wooden Toggle
P) |
- |
375 |
|
Excluding GST |
| 4.3.1
Table 6
Fig. 4.(Dimensions of the Asoka Chakra ) |
- |
375 |
|
Excluding GST |
|
- |
- - |
| 12747 |
Testtex India Laboratories Pvt. Ltd., Mumbai
| 7126506
| IS 5470 (2002) |
Dicalcium phosphate, animal feed grade - Specification (First Revision) |
Animal Feed Grade |
7000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.0(Description) |
- |
200 |
|
Total Testing Charges Rs 7000 (Discount 10 % for BIS) |
| 4.4 Table 1(Moisture) |
- |
500 |
|
- |
| 4.4 Table 1(Calcium ( as Ca )) |
- |
500 |
|
- |
| 4.4 Table 1(Phosphorus ( as P )) |
- |
500 |
|
- |
| 4.4 Table 1(Fluorine ( as F )) |
- |
1500 |
|
- |
| 4.4 Table 1(Acid insoluble ash) |
- |
500 |
|
- |
| 4.4 Table 1(Lead ( as Pb )) |
- |
500 |
|
- |
| 4.4 Table 1(Arsenic ( as As2O3 )) |
- |
500 |
|
- |
| 4.4 Table 1(Total ash) |
- |
500 |
|
- |
| 4.4 Table 1(Presence of proteinous/organic impurities) |
- |
500 |
|
- |
| 4.1(Sieve Test) |
- |
300 |
|
- |
| 4.2(Microbial Parameter) |
- |
1000 |
|
Clostridium spp |
|
08 Apr, 2028 |
- Included w.e.f. 28.08.2023
Exclusion: Cl.4.2 (Microbial Parameter) |
| 12748 |
Testtex India Laboratories Pvt. Ltd., Mumbai
| 7126506
| IS 1166 (2022) |
SWEETENED CONDENSED MILK, SWEETENED CONDENSED PARTLY SKIMMED MILK, SWEETENED CONDENSED SKIMMED MILK AND SWEETENED CONDENSD HIGH FAT MILK- SPECIFICATION (Third Revision of IS 1166) |
- |
33100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.8(2,4-Dichlorophenoxy Acetic acid) |
- |
0 |
|
Total Testting Charges Rs 33,100 including Pesticide Residues, Antibiotics and Veterinary Drugs (Rs 8,000/ for Pesticide Residues only and Rs12,000/ for Veterinary Drugs). |
| 4.8(Acephate (expressed as mixture of Methamidophos and acephate)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 10,000 |
| 4.8(Acetamiprid) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Azoxystrobin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Sum of benomyl & carbendazim expressed as carbendazim)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Bifenthrin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Bitertanol) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Buprofezin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Carbaryl) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Carbendazim) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Carbofuran (sum of carbofuran & 3-hydroxy carbofuran expressedas carbofuran)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Chlorantraniliprole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Chlorothalonil) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Chlorpyriphos) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Chlothianidin (Chlothianidin & its metabolite Thiazolymethylguanidine(TMG) ,Thiazolymethylurea(TZMU),Methylnitroguanidine(MNG)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Cypermethrin (sum of isomers) (Fat soluble residue)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Deltamethrin (Decamethrin)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Dichlorvos (DDVP) (content of dichloroacetaldehyde (D.C.A.)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Difenoconazole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Dimethoate) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Dinotefuron) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Mancozeb) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(metiram as CS2) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Edifenphos) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Emamectin Benzoate) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Ethion (Residues to be determined as ethion & its oxygen analogue and expressed as ethion)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Ethofenprox (Etofenprox)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Fenpropathrin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Fenvalerate (fat soluble residue)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Fipronil) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Flubendiamide) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Flusilazole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Glufosinate Ammonium) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Imidacloprid) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Indoxacarb) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Kresoxim Methyl) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Methomyl) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Metolachlor) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Monocrotophos) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Oxydemeton-Methyl) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Paraquat dichloride (Determined as Paraquatcations)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 10,000 |
| 4.8(Penconazole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Phenthoate) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Phorate (sum of phorate,its oxygen analogue and their sulphoxides & sulphones, expressed as Phorate)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Pirimiphos-methyl) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Propiconazole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Pyraclostrobin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Tebuconazole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Thiacloprid) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Thiophanate-Methyl) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Thiamethoxam) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Triadimefon) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Trichlorfon) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide residue Rs 8,000 |
| 4.8(Ampicillin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Apramycin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Albendazole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Chlotetracycline/Oxytetracycline/Tetracycline) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Ceftiofur) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Cefphactril) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Doramectin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Diminazene) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Flunixin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Febantel/Fenbendazole/Oxyfendazole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Ivermectin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 15,000 |
| 4.8(Lincomycin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Monensin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Meloxicam) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Neomycin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Oxyclozanide) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Parbendazole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Spectinomycin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Sulfadiazine) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Sulfanilamide) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Sulfaquinoxaline) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Sulfa Chloropyrazine) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Thiabendazole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Trimethoprim) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Tylosin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Virginiamycin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.9,Table 3(i)(Lead -IS 12074) |
- |
400 |
|
- |
| 4.9,Table 3(ii)(Arsenic - IS 11124) |
- |
400 |
|
- |
| 4.9,Table 3(iii)(Aflatoxin M1 - ISO 14501 or ISO 14674 or any other international validated method) |
- |
2000 |
|
- |
| 4.9,Table 3(iv)(Melamine - IS 16195) |
- |
2500 |
|
- |
| 4.2(Taste , Flavour,Colour & Odour. Free from rancid , fruity , moldy , tallowy , cooked , sour, sandy and any other objectionable odour and taste -IS 1166) |
- |
200 |
|
- |
| (Clause 4.6)(Measurement of size and count of lactose crystals) |
- |
700 |
|
- |
| ( Clauses 4.1 and 4.7) Tabel 1 (iii)(Milk solid not fat) |
- |
300 |
|
- |
| ( Clauses 4.1 and 4.7) Tabel 1 (ii)(Milk Fat) |
- |
300 |
|
- |
| ( Clauses 4.1 and 4.7) Tabel 1 (v)(Accelerated storage test) |
- |
300 |
|
- |
| 4.8(Pesticide Residues) |
- |
8000 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Antibiotic and Veterinary drug residues) |
- |
12000 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| "4.7 Table 2 (i) "(Aerobic plate count-IS 5402 (Part 1)) |
- |
400 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| (Clause 4.7) Tabel 2 (ii)(Coliform count) |
- |
400 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| (Clause 4.7) Tabel 2 (iii)(Staphylococcus Aureus (Coagulates positive)) |
- |
400 |
|
- |
| (Clause 4.7) Tabel 2 (iv)(Yeast and mould count) |
- |
400 |
|
- |
| (Clause 4.7) Tabel 2 (v)(Salmonella) |
- |
600 |
|
- |
| (Clause 4.7) Tabel 2 (vi)(Listeria monocytogens) |
- |
600 |
|
- |
| (Clause 4.7) Tabel 2 (vii)(E Coli) |
- |
400 |
|
- |
| 4.8(2,4-Dichlorophenoxy Acetic acid) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Acephate (expressed as mixture of Methamidophos and acephate)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Acetamiprid) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Azoxystrobin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Sum of benomyl & carbendazim expressed as carbendazim)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Bifenthrin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Bitertanol) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Buprofezin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Carbaryl) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Carbendazim) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Carbofuran (sum of carbofuran & 3-hydroxy carbofuran expressedas carbofuran)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Chlorantraniliprole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Chlorothalonil) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Chlorpyriphos) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Chlothianidin (Chlothianidin & its metabolite Thiazolymethylguanidine(TMG) ,Thiazolymethylurea(TZMU),Methylnitroguanidine(MNG)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Cypermethrin (sum of isomers) (Fat soluble residue)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Deltamethrin (Decamethrin)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Dichlorvos (DDVP) (content of dichloroacetaldehyde (D.C.A.)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Difenoconazole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Dimethoate) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Dinotefuron) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Mancozeb) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(metiram as CS2) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Edifenphos) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Emamectin Benzoate) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Ethion (Residues to be determined as ethion & its oxygen analogue and expressed as ethion)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Ethofenprox (Etofenprox)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Fenpropathrin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Fenvalerate (fat soluble residue)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Fipronil) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Flubendiamide) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Flusilazole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Glufosinate Ammonium) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Imidacloprid) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Indoxacarb) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Kresoxim Methyl) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Methomyl) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Metolachlor) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Monocrotophos) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Oxydemeton-Methyl) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Paraquat dichloride (Determined as Paraquatcations)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Penconazole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Phenthoate) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Phorate (sum of phorate,its oxygen analogue and their sulphoxides & sulphones, expressed as Phorate)) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Pirimiphos-methyl) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Propiconazole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Pyraclostrobin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Tebuconazole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Thiacloprid) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Thiophanate-Methyl) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Thiamethoxam) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Triadimefon) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Trichlorfon) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Pesticide Residue Rs 8,000 |
| 4.8(Ampicillin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Apramycin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Albendazole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Chlotetracycline/Oxytetracycline/Tetracycline) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Ceftiofur) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Cefphactril) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Doramectin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Diminazene) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Flunixin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Febantel/Fenbendazole/Oxyfendazole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Ivermectin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Lincomycin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Monensin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Meloxicam) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Neomycin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Oxyclozanide) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Parbendazole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Spectinomycin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Sulfadiazine) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Sulfanilamide) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Sulfaquinoxaline) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Sulfa Chloropyrazine) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Thiabendazole) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Trimethoprim) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.8(Tylosin) |
- |
0 |
|
- |
| 4.8(Virginiamycin) |
- |
0 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.9,Table 3(i)(Lead -IS 12074) |
- |
400 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| 4.9,Table 3(ii)(Arsenic - IS 11124) |
- |
400 |
|
- |
| 4.9,Table 3(iii)(Aflatoxin M1 - ISO 14501 or ISO 14674 or any other international validated method) |
- |
2000 |
|
- |
| 4.9,Table 3(iv)(Melamine - IS 16195) |
- |
2500 |
|
- |
| 4.2(Taste , Flavour,Colour & Odour. Free from rancid , fruity , moldy , tallowy , cooked , sour, sandy and any other objectionable odour and taste -IS 1166) |
- |
250 |
|
- |
| (Clause 4.6)(Measurement of size and count of lactose crystals) |
- |
700 |
|
- |
| ( Clauses 4.1 and 4.7) Tabel 1 (iii)(Milk solid not fat) |
- |
400 |
|
- |
| ( Clauses 4.1 and 4.7) Tabel 1 (ii)(Milk Fat) |
- |
400 |
|
- |
| ( Clauses 4.1 and 4.7) Tabel 1 (v)(Accelerated storage test) |
- |
300 |
|
- |
| 4.8(Pesticide Residues) |
- |
8000 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 8,000 |
| 4.8(Antibiotic and Veterinary drug residues) |
- |
12000 |
|
Clause no. 4.8, Combined testing charges for Antibiotic and veterinary drug residue Rs 12,000 |
| "4.7 Table 2 (i) "(Aerobic plate count-IS 5402 (Part 1)) |
- |
400 |
|
- |
| (Clause 4.7) Tabel 2 (ii)(Coliform count) |
- |
400 |
|
- |
| (Clause 4.7) Tabel 2 (iii)(Staphylococcus Aureus (Coagulates positive)) |
- |
400 |
|
- |
| (Clause 4.7) Tabel 2 (iv)(Yeast and mould count) |
- |
400 |
|
- |
| (Clause 4.7) Tabel 2 (v)(Salmonella) |
- |
500 |
|
- |
| (Clause 4.7) Tabel 2 (vi)(Listeria monocytogens) |
- |
600 |
|
- |
| (Clause 4.7) Tabel 2 (vii)(E Coli) |
- |
400 |
|
- |
| 4.8(2,4-Dichlorophenoxy Acetic acid) |
- |
0 |
|
- |
| 4.8(Acephate (expressed as mixture of Methamidophos and acephate)) |
- |
0 |
|
- |
| 4.8(Acetamiprid) |
- |
0 |
|
- |
| 4.8(Azoxystrobin) |
- |
0 |
|
- |
| 4.8(Sum of benomyl & carbendazim expressed as carbendazim)) |
- |
0 |
|
- |
| 4.8(Bifenthrin) |
- |
0 |
|
- |
| 4.8(Bitertanol) |
- |
0 |
|
- |
| 4.8(Buprofezin) |
- |
0 |
|
- |
| 4.8(Carbaryl) |
- |
0 |
|
- |
| 4.8(Carbendazim) |
- |
0 |
|
- |
| 4.8(Carbofuran (sum of carbofuran & 3-hydroxy carbofuran expressedas carbofuran)) |
- |
0 |
|
- |
| 4.8(Chlorantraniliprole) |
- |
0 |
|
- |
| 4.8(Chlorothalonil) |
- |
0 |
|
- |
| 4.8(Chlorpyriphos) |
- |
0 |
|
- |
| 4.8(Chlothianidin (Chlothianidin & its metabolite Thiazolymethylguanidine(TMG) ,Thiazolymethylurea(TZMU),Methylnitroguanidine(MNG)) |
- |
0 |
|
- |
| 4.8(Cypermethrin (sum of isomers) (Fat soluble residue)) |
- |
0 |
|
- |
| 4.8(Deltamethrin (Decamethrin)) |
- |
0 |
|
- |
| 4.8(Dichlorvos (DDVP) (content of dichloroacetaldehyde (D.C.A.)) |
- |
0 |
|
- |
| 4.8(Difenoconazole) |
- |
0 |
|
- |
| 4.8(Dimethoate) |
- |
0 |
|
- |
| 4.8(Dinotefuron) |
- |
0 |
|
- |
| 4.8(Mancozeb) |
- |
0 |
|
- |
| 4.8(metiram as CS2) |
- |
0 |
|
- |
| 4.8(Edifenphos) |
- |
0 |
|
- |
| 4.8(Emamectin Benzoate) |
- |
0 |
|
- |
| 4.8(Ethion (Residues to be determined as ethion & its oxygen analogue and expressed as ethion)) |
- |
0 |
|
- |
| 4.8(Ethofenprox (Etofenprox)) |
- |
0 |
|
- |
| 4.8(Fenpropathrin) |
- |
0 |
|
- |
| 4.8(Fenvalerate (fat soluble residue)) |
- |
0 |
|
- |
| 4.8(Fipronil) |
- |
0 |
|
- |
| 4.8(Flubendiamide) |
- |
0 |
|
- |
| 4.8(Flusilazole) |
- |
0 |
|
- |
| 4.8(Glufosinate Ammonium) |
- |
0 |
|
- |
| 4.8(Imidacloprid) |
- |
0 |
|
- |
| 4.8(Indoxacarb) |
- |
0 |
|
- |
| 4.8(Kresoxim Methyl) |
- |
0 |
|
- |
| 4.8(Methomyl) |
- |
0 |
|
- |
| 4.8(Metolachlor) |
- |
0 |
|
- |
| 4.8(Monocrotophos) |
- |
0 |
|
- |
| 4.8(Oxydemeton-Methyl) |
- |
0 |
|
- |
| 4.8(Paraquat dichloride (Determined as Paraquatcations)) |
- |
0 |
|
- |
| 4.8(Penconazole) |
- |
0 |
|
- |
| 4.8(Phenthoate) |
- |
0 |
|
- |
| 4.8(Phorate (sum of phorate,its oxygen analogue and their sulphoxides & sulphones, expressed as Phorate)) |
- |
0 |
|
- |
| 4.8(Pirimiphos-methyl) |
- |
0 |
|
- |
| 4.8(Propiconazole) |
- |
0 |
|
- |
| 4.8(Pyraclostrobin) |
- |
0 |
|
- |
| 4.8(Tebuconazole) |
- |
0 |
|
- |
| 4.8(Thiacloprid) |
- |
0 |
|
- |
| 4.8(Thiophanate-Methyl) |
- |
0 |
|
- |
| 4.8(Thiamethoxam) |
- |
0 |
|
- |
| 4.8(Triadimefon) |
- |
0 |
|
- |
| 4.8(Trichlorfon) |
- |
0 |
|
- |
| 4.8(Ampicillin) |
- |
0 |
|
- |
| 4.8(Apramycin) |
- |
0 |
|
- |
| 4.8(Albendazole) |
- |
0 |
|
- |
| 4.8(Chlotetracycline/Oxytetracycline/Tetracycline) |
- |
0 |
|
- |
| 4.8(Ceftiofur) |
- |
0 |
|
- |
| 4.8(Cefphactril) |
- |
0 |
|
- |
| 4.8(Doramectin) |
- |
0 |
|
- |
| 4.8(Diminazene) |
- |
0 |
|
- |
| 4.8(Flunixin) |
- |
0 |
|
- |
| 4.8(Febantel/Fenbendazole/Oxyfendazole) |
- |
0 |
|
- |
| 4.8(Ivermectin) |
- |
0 |
|
- |
| 4.8(Lincomycin) |
- |
0 |
|
- |
| 4.8(Monensin) |
- |
0 |
|
- |
| 4.8(Meloxicam) |
- |
0 |
|
- |
| 4.8(Neomycin) |
- |
0 |
|
- |
| 4.8(Oxyclozanide) |
- |
0 |
|
- |
| 4.8(Parbendazole) |
- |
0 |
|
- |
| 4.8(Spectinomycin) |
- |
0 |
|
- |
| 4.8(Sulfadiazine) |
- |
0 |
|
- |
| 4.8(Sulfanilamide) |
- |
0 |
|
- |
| 4.8(Sulfaquinoxaline) |
- |
0 |
|
- |
| 4.8(Sulfa Chloropyrazine) |
- |
0 |
|
- |
| 4.8(Thiabendazole) |
- |
0 |
|
- |
| 4.8(Trimethoprim) |
- |
0 |
|
- |
| 4.8(Tylosin) |
- |
0 |
|
- |
| 4.8(Virginiamycin) |
- |
0 |
|
- |
| 4.9,Table 3(i)(Lead -IS 12074) |
- |
400 |
|
- |
| 4.9,Table 3(ii)(Arsenic - IS 11124) |
- |
400 |
|
- |
| 4.9,Table 3(iii)(Aflatoxin M1 - ISO 14501 or ISO 14674 or any other international validated method) |
- |
2000 |
|
- |
| 4.9,Table 3(iv)(Melamine - IS 16195) |
- |
2500 |
|
- |
| 4.2(Taste , Flavour,Colour & Odour. Free from rancid , fruity , moldy , tallowy , cooked , sour, sandy and any other objectionable odour and taste -IS 1166) |
- |
250 |
|
- |
| (Clause 4.6)(Measurement of size and count of lactose crystals) |
- |
700 |
|
- |
| ( Clauses 4.1 and 4.7) Tabel 1 (iii)(Milk solid not fat) |
- |
400 |
|
- |
| ( Clauses 4.1 and 4.7) Tabel 1 (ii)(Milk Fat) |
- |
400 |
|
- |
| ( Clauses 4.1 and 4.7) Tabel 1 (v)(Accelerated storage test) |
- |
300 |
|
- |
| 4.8(Pesticide Residues) |
- |
8000 |
|
- |
| 4.8(Antibiotic and Veterinary drug residues) |
- |
1200 |
|
- |
| "4.7 Table 2 (i) "(Aerobic plate count-IS 5402 (Part 1)) |
- |
400 |
|
- |
| (Clause 4.7) Tabel 2 (ii)(Coliform count) |
- |
400 |
|
- |
| (Clause 4.7) Tabel 2 (iii)(Staphylococcus Aureus (Coagulates positive)) |
- |
400 |
|
- |
| (Clause 4.7) Tabel 2 (iv)(Yeast and mould count) |
- |
400 |
|
- |
| (Clause 4.7) Tabel 2 (v)(Salmonella) |
- |
500 |
|
- |
| (Clause 4.7) Tabel 2 (vi)(Listeria monocytogens) |
- |
600 |
|
- |
| (Clause 4.7) Tabel 2 (vii)(E Coli) |
- |
400 |
|
- |
|
08 Apr, 2028 |
- Included w.e.f. 28.08.2023 |
| 12749 |
Hi Physix Laboratory India Private Limited, Pune
| 7126926
| IS 16444 (2015) |
AC static direct connected watthour smart meter class 1 and 2 - Specification |
Single Phase and Three Phase |
600000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.8(Marking of smart meters
Name plate) |
- |
1000 |
|
- |
| 6.3(Clearance and creepage distances) |
- |
1000 |
|
- |
| 11.0(Smart meter functional requirements) |
- |
5000 |
|
- |
| 9, 10.6(Test of Smart Meter Communicability) |
- |
10000 |
|
- |
| 10.3(Test of Display) |
- |
2000 |
|
- |
| 10.5(Test for Data Exchange Protocol) |
- |
80000 |
|
- |
| 7.2, 10.4(Performance Requirements for Load Switching (UC1)) |
- |
185000 |
|
For Three Phase and Rs-95000/- for Single Phase |
| 7.2, 10.4(Dielectric strength (G-8)) |
- |
7500 |
|
- |
| 7.2, 10.4(Minimum switched current (G-7)) |
- |
7500 |
|
- |
| 7.2, 10.4(Short circuit current carrying capacity (G-6)) |
- |
35000 |
|
For Three Phase and Rs-30000/- for Single Phase |
| 7.2, 10.4(Line to load voltage surge withstand (G-4)) |
- |
10000 |
|
- |
| 7.2, 10.4(Electrical endurance (G-3)) |
- |
130000 |
|
For Three Phase and Rs-105000/- for Single Phase |
| 7.2, 10.4(Normal operation (G-2)) |
- |
10000 |
|
- |
| 6.5(Test of resistance to heat and fire) |
- |
3000 |
|
- |
| 6.5(Protection against penetration of dust and water) |
- |
5000 |
|
- |
| 6.5(Spring Hammer test) |
- |
1000 |
|
- |
| 6.5(Shock test) |
- |
8000 |
|
- |
| 6.5(Vibration test) |
- |
10000 |
|
- |
| 6.9(Damp heat cyclic test) |
- |
10000 |
|
- |
| 6.9(Cold test) |
- |
10000 |
|
- |
| 6.9(Dry heat test) |
- |
8000 |
|
- |
| 6.11(Surge Immunity test) |
- |
10000 |
|
- |
| 6.11(Test of immunity to electromagnetic HF field) |
- |
48000 |
|
- |
| 6.11(Test of immunity to electrostatic discharge) |
- |
10000 |
|
- |
| 6.11(Fast transient burst test) |
- |
12000 |
|
- |
| 6.11(Radio interference measurement) |
- |
55000 |
|
For Three Phase and Rs-52000/- for Single Phase |
| 6.10.7(Test of influence of immunity to earth fault) |
- |
5000 |
|
- |
| 6.10.5(Test of influence of heating) |
- |
2000 |
|
- |
| 6.10.4(Test of influence of self-heating) |
- |
3000 |
|
- |
| 6.10.3(Test of influence of short time over currents) |
- |
8000 |
|
- |
| 6.10.2(Test of influence of supply voltage) |
- |
2000 |
|
- |
| 6.10.1(Test of power consumption) |
- |
1000 |
|
- |
| 6.12(Test of influence quantities) |
- |
20000 |
|
- |
| 6.12(Test of repeatability of error ) |
- |
3000 |
|
- |
| 6.12(Test of ambient temperature influence) |
- |
2000 |
|
- |
| 6.12(Test of no-load condition) |
- |
2000 |
|
- |
| 6.12(Test of starting condition) |
- |
2000 |
|
- |
| 6.12(Test of meter constant) |
- |
3000 |
|
For Three Phase and Rs-2000/- for Single Phase |
| 6.12(Test on limits of error due to variation of the current) |
- |
4000 |
|
For Three Phase and Rs-3000/- for Single Phase |
| 6.10.6(Insulation resistance test) |
- |
1000 |
|
- |
| 6.10.6(ac high voltage test) |
- |
2000 |
|
- |
| 6.10.6(Impulse voltage test) |
- |
5000 |
|
- |
| 6.2(General and constructional requirements) |
- |
6000 |
|
- |
| 6.6(Display of measured values) |
- |
1000 |
|
- |
| 6.7(Output device) |
- |
3000 |
|
- |
| cl 11.1 of IS 13779(Limits of Error and Interpretation or Test Results) |
- |
1000 |
|
- |
| 7.2, 10.4(Fault current making capacity (G-5)) |
- |
35000 |
|
For Three Phase and Rs-30000/- for Single Phase |
|
20 Jun, 2028 |
- Included w.e.f. 02.08.2023. Exclusion: 1. Cl.10.5 (Data exchange protocol (Granted for only six months up to 02.08.2024))
2. Cl.11 (Functional requirements (Granted for only six months up to 02.08.2024))
3. Cl.10.6.1 (The modules for WAN/NAN/HD
4. Cl.10.6.2 (Tests for smart meter communicability (Granted for only six months up to 02.08.2024)) |
| 12750 |
Hi Physix Laboratory India Private Limited, Pune
| 7126926
| IS 16444 : Part 2 (2017) |
AC static transformer operated watthour and var - Hour smart meters, class 0.2 S, 0.5 S and 1.0 S: Part 2 specification transformer operated smart meters |
Single Phase and Three Phase |
300000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.8(Marking of meters
Name plate) |
- |
1000 |
|
For Single and Three Phase |
| 6.3(Clearance and creepage distances) |
- |
1000 |
|
For Single and Three Phase |
| 10.0(Smart Meter Functional Requirements) |
- |
5000 |
|
For Single and Three Phase |
| 8, 9.5(Smart Meter Communicability) |
- |
10000 |
|
For Single and Three Phase |
| 9.3(Test of Display) |
- |
1000 |
|
For Single and Three Phase |
| 7, 9.4(Data Exchange for Electricity Meter Reading, Tariff and Load Control Companion Specification
(The requirement as per IS 15959 : Part 1 & Part 3 shall apply)) |
- |
80000 |
|
For Single and Three Phase |
| 6.4(Test of resistance to heat and fire) |
- |
2000 |
|
For Single and Three Phase |
| 6.5(Test of protection against penetration of dust and water) |
- |
5000 |
|
For Single and Three Phase |
| 6.5(Spring hammer test) |
- |
1000 |
|
For Single and Three Phase |
| 6.5(Shock test) |
- |
7500 |
|
For Single and Three Phase |
| 6.5(Vibration test) |
- |
9500 |
|
For Single and Three Phase |
| 6.9(Damp heat cyclic test) |
- |
10000 |
|
For Single and Three Phase |
| 6.9(Cold test) |
- |
10000 |
|
For Single and Three Phase |
| 6.9(Dry heat test) |
- |
8000 |
|
For Single and Three Phase |
| 6.11(Surge Immunity test) |
- |
8000 |
|
For Single and Three Phase |
| 6.11(Test of immunity to electromagnetic HF field) |
- |
35000 |
|
For Single and Three Phase |
| 6.11(Test of immunity to electrostatic discharge) |
- |
10000 |
|
For Single and Three Phase |
| 6.11(Fast transient burst test) |
- |
10000 |
|
For Single and Three Phase |
| 6.11(Radio interference measurement) |
- |
35000 |
|
for Three Phase and Rs-30000 for Single Phase |
| 6.10.7(Test of immunity to earth/phase fault) |
- |
4000 |
|
For Single and Three Phase |
| 6.10.5(Test of influence of heating) |
- |
2000 |
|
For Single and Three Phase |
| 6.10.4(Test of influence of self-heating) |
- |
3000 |
|
For Single and Three Phase |
| 6.10.3(Test of influence of short time over currents) |
- |
3000 |
|
For Single and Three Phase |
| 6.10.2(Test of influence of supply voltage) |
- |
2000 |
|
For Single and Three Phase |
| 6.10.1(Test of power consumption) |
- |
1000 |
|
For Single and Three Phase |
| 6.12(Test of influence quantities) |
- |
8000 |
|
For Single and Three Phase |
| 6.12(Test of repeatability of error) |
- |
4000 |
|
For Single and Three Phase |
| 6.12(Test of ambient temperature influence) |
- |
2000 |
|
For Single and Three Phase |
| 6.12(Test of no-load condition) |
- |
2000 |
|
for Three Phase and Rs-1500 for Single Phase |
| 6.12(Test of starting condition) |
- |
2000 |
|
for Three Phase and Rs-1500 for Single Phase |
| 6.12(Test of meter constant) |
- |
2000 |
|
For Single and Three Phase |
| 6.12(Test on limits of error) |
- |
3000 |
|
For Single and Three Phase |
| 6.10.6(Insulation test) |
- |
1000 |
|
For Single and Three Phase |
| 6.10.6(ac high voltage test) |
- |
1000 |
|
For Single and Three Phase |
| 6.10.6(Impulse voltage test) |
- |
3000 |
|
For Single and Three Phase |
| 6.7(Output device) |
- |
3000 |
|
For Single and Three Phase |
| 6.6(Display of measured values) |
- |
1000 |
|
For Single and Three Phase |
| 6.2.2(Terminal Cover(s)) |
- |
1000 |
|
For Single and Three Phase |
| 6.2(General Constructional requirements) |
- |
0 |
|
Already included |
| 6.2.1(Terminals, terminal block and protective earth terminal) |
- |
2000 |
|
For Single and Three Phase |
| 6.1(Electrical Requirments) |
- |
1000 |
|
For Single and Three Phase |
| 6.8(Marking of meters
Name plate) |
- |
- |
|
- |
| 6.3(Clearance and creepage distances) |
- |
- |
|
- |
| 6.1(Electrical Requirments) |
- |
- |
|
- |
|
20 Jun, 2028 |
- Included w.e.f. 02.08.2023. Exclusion: Cl.9.4 (Data exchange protocol (Granted for only six months up to 02.08.2024))
2. Cl.10 (Functional requirements (Granted for only six months up to 02.08.2024))
3. Cl.9.5.1 (The modules for WAN/NAN/HD
4 Cl.9.5.2 (Test for smart meter communicability (Granted for only six months up to 02.08.2024)) |