| 12931 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 1997 (2008) |
Laboratory glassware - Burettes (Third Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 11 (Markings ) |
- |
|
|
|
| 5.1 (Class of Accuracy) |
- |
|
|
|
| 5.2 (Types) |
- |
|
|
|
| 8 (Construction) |
- |
|
|
|
| Table 2 (i) Scale length ) |
- |
|
|
|
| Table 3 ( ii) Overall length ) |
- |
|
|
|
| Table 4 (iii) Distance of Zero line from top of burette ) |
- |
|
|
|
| Table 5 (iv) Distance of lowest graduation line from the top of stopcock ) |
- |
|
|
|
| Table 6 (v) Length of tube of uniform bore below graduation line ) |
- |
|
|
|
| Table 7 (vi) Distance of end of jet from underside of stopcock ) |
- |
|
|
|
| 8.2 ( c) Top of burette ) |
- |
|
|
|
| 8.3 (d) Stopcock and similar devices) |
- |
|
|
|
| 8.4 (e) Stop Cock Leakage) |
- |
|
|
|
| 8.5 ( f) Delivery jet) |
- |
|
|
|
| 8.6 (g) Delivery time ) |
- |
|
|
|
| 8.6 (g) Delivery time ) |
- |
|
|
|
| 9 (Graduations, figuring and patterns ) |
- |
|
|
|
| 9.1 (a) Graduations patterns ) |
- |
|
|
|
| 9.2 (Position of graduation line) |
- |
|
|
|
| 9.3 (c) Marking of graduation lines ) |
- |
|
|
|
| 12 (. Visibility of graduation line) |
- |
|
|
|
|
- |
- Excluding Material and Accuracy test not available, |
| 12932 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 4985 (2000) |
Unplasticized pvc pipes for potable water supplies - Specification (Third Revision) |
- |
32825 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 11.2(Resistance to External Blows at 0°C) |
- |
1300 |
|
- |
| 11.1.1(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Plumbing pipes) |
- |
850 |
|
- |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Integral Sealing Ring
Sockets) |
- |
850 |
|
- |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)-for Integral Sealing Ring
Sockets) |
- |
5000 |
|
- |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)) |
- |
850 |
|
- |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)) |
- |
11000 |
|
- |
| 10.6(PHYSICAL AND CHEMICAL CHARACTERISTICS- Density) |
- |
500 |
|
- |
| 10.5(PHYSICAL AND CHEMICAL CHARACTERISTICS- Vicat Softening Temperature) |
- |
1100 |
|
- |
| 10.4(PHYSICAL AND CHEMICAL CHARACTERISTICS- Reversion Test) |
- |
900 |
|
- |
| 10.2(PHYSICAL AND CHEMICAL CHARACTERISTICS-Opacity) |
- |
575 |
|
- |
| 10.1.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
300 |
|
- |
| 9.1(PIPE ENDS) |
- |
0 |
|
- |
| 8(SEALING RINGS) |
- |
0 |
|
- |
| 7.2.1.2-Table 4(DIMENSIONS-Sockets for elastomeric sealing ring joints-Socket inner Diameter) |
- |
500 |
|
- |
| 7.2.1.2(a)-Table 5(DIMENSIONS-Sockets for elastomeric sealing ring joints-Minimum depth of engagement) |
- |
0 |
|
The test charges has already been taken in cl. no. 7.2.1.2-Table 4 |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Maximum)) |
- |
0 |
|
The test charges has already been taken in cl. no. 7.2.1.2-Table 4 |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Minimum)) |
- |
0 |
|
The test charges has already been taken in cl. no. 7.2.1.2-Table 4 |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Minimum Length) |
- |
0 |
|
The test charges has already been taken in cl. no. 7.2.1.2-Table 4 |
| 7.2.1(DIMENSIONS-Socket) |
- |
0 |
|
The test charges has already been taken in cl. no. 7.2.1.2-Table 4 |
| 7.1.2.1(DIMENSIONS-PIPE-Average Thickness) |
- |
0 |
|
The test charges has already been taken in cl. no. 7.2.1.2-Table 4 |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Maximum)) |
- |
0 |
|
The test charges has already been taken in cl. no. 7.2.1.2-Table 4 |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Minimum)) |
- |
0 |
|
The test charges has already been taken in cl. no. 7.2.1.2-Table 4 |
| 7.1.1.2(DIMENSIONS-PIPE-Ovality (Maximum)) |
- |
0 |
|
The test charges has already been taken in cl. no. 7.2.1.2-Table 4 |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Maximum)) |
- |
0 |
|
The test charges has already been taken in cl. no. 7.2.1.2-Table 4 |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Minimum)) |
- |
0 |
|
The test charges has already been taken in cl. no. 7.2.1.2-Table 4 |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. Variation) |
- |
0 |
|
The test charges has already been taken in cl. no. 7.2.1.2-Table 4 |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Mamimum)) |
- |
0 |
|
The test charges has already been taken in cl. no. 7.2.1.2-Table 4 |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Minimum)) |
- |
0 |
|
The test charges has already been taken in cl. no. 7.2.1.2-Table 4 |
| 7(DIMENSIONS-PIPE-Nominal Diameter) |
- |
0 |
|
The test charges has already been taken in cl. no. 7.2.1.2-Table 4 |
| Clause 10.7(Sulphated Ash Content) |
- |
950 |
|
- |
| 10.1(Colour) |
- |
0 |
|
- |
| D-2.1.2.4(Effect on Water Test) |
- |
3000 |
|
- |
| 7.2.1.1
Table3
(Angle of taper (Note-1)) |
- |
0 |
|
- |
| 10.1(Surface Finish) |
- |
0 |
|
- |
| 6.1.2(PVC Resin) |
- |
4100 |
|
VCM Content + K-Value |
|
31 Dec, 2026 |
- - |
| 12933 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 1065 : Part 2 (2019) |
Stable bleaching powder - Specification: Part 2 treatment of water intended for drinking |
- |
Rs. 7,024/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 5.3, Table-1, Sr.no. 1 (Available Chlorine) |
- |
|
|
|
| Cl. 5.3, Table-1, Sr.no. 2 (Stability, loss of Chlorine on the basis of initial available chlorine) |
- |
|
|
|
| Cl. 5.3, Table-1, Sr.no. 3 (Moisture ) |
- |
|
|
|
| Cl. 5.3, Table-1, Sr.no. 4 (Particle size(passing though 1.70 mm I.S. Sieve)) |
- |
|
|
|
| Clause 5.2 (Description) |
- |
|
|
|
| Clause 5.4 (Keeping Quality ) |
- |
|
|
|
|
- |
- Test facility not available for the following:
1. Pb, As, Cr , Mn ,Se,Hg,Cd |
| 12934 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 758 (1988) |
Specification for cotton gauze, absorbent, non-sterilized (fourth revision) |
- |
Rs 2400/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1,Table 1,Sr.No.vii
IS : 1390 (pH value) |
- |
|
|
|
| 3.1,Table 1,Sr.No.viii
IS : 1383 (Scouring Loss) |
- |
|
|
|
|
- |
- - |
| 12935 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 1993 (2018) |
Cold - Reduced tinmill products - Electrolytic tinplate (Fifth Revision) |
For all grades except for the tests mentioned in remarks |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 9.2 (Hardness requirement ) |
- |
|
|
|
| Cl 9.3 (Tensile requirement ) |
- |
|
|
|
| Cl 10.2.1 (Coils) |
- |
|
|
|
| Cl 10.2.2 (Coils) |
- |
|
|
|
| Cl 10.3.1 (Sheet) |
- |
|
|
|
| Cl 10.3.2 (Sheet) |
- |
|
|
|
| Cl 10.3.2.1 (Sheet) |
- |
|
|
|
| Cl 10.3.2.3 (Sheet) |
- |
|
|
|
| Annex-C (Sulphur) |
- |
|
|
|
| Annex-C (Phosphorus) |
- |
|
|
|
| Annex-C (Manganese) |
- |
|
|
|
| Annex-C (Nitrogen) |
- |
|
|
|
| Annex-C (Chromium) |
- |
|
|
|
| Annex-C (Molybdenum) |
- |
|
|
|
| Annex-C (Copper) |
- |
|
|
|
| Annex-C (Nickel) |
- |
|
|
|
| Cl 8 (Tin Coating mass ) |
- |
|
|
|
| Annex-C (Carbon ) |
- |
|
|
|
| Annex-C (Silicon) |
- |
|
|
|
|
- |
- Excluding Tin coating for individual sample, Si( optional test) |
| 12936 |
BIS, Bengaluru Branch Laboratory (BNBL)
| None
| IS 15644 (2006) |
Safety of electric toys |
Electric Toys excluding wheeled ride-on toys & Annex E |
7050.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.0 (Marking and instructions) |
- |
|
|
|
| 8.0 (Power Input) |
- |
|
|
|
| 9.0 (Heating and abnormal operation) |
- |
|
|
|
| 10.0 (Electrical strength at operating temperature) |
- |
|
|
|
| 11.1 (Moisture resistance) |
- |
|
|
|
| 7.0 (Marking and instructions) |
- |
|
|
|
| 8.0 (Power Input) |
- |
|
|
|
| 11.1 (Moisture resistance) |
- |
|
|
|
| 9.0 (Heating and abnormal operation) |
- |
|
|
|
| 11.1 (Moisture resistance) |
- |
|
|
|
| 9.0 (Heating and abnormal operation) |
- |
|
|
|
| 11.2 (Resistant to humidity) |
- |
|
|
|
| 9.0 (Heating and abnormal operation) |
- |
|
|
|
| 11.2 (Resistant to humidity) |
- |
|
|
|
| 9.0 (Heating and abnormal operation) |
- |
|
|
|
| 12.0 (Electric strength at room temperature) |
- |
|
|
|
| 9.0 (Heating and abnormal operation) |
- |
|
|
|
| 10.0 (Electrical strength at operating temperature) |
- |
|
|
|
| 13.0 (Mechanical strength) |
- |
|
|
|
| 10.0 (Electrical strength at operating temperature) |
- |
|
|
|
| 14.1 (Construction) |
- |
|
|
|
| 10.0 (Electrical strength at operating temperature) |
- |
|
|
|
| 14.1 (Construction) |
- |
|
|
|
| 10.0 (Electrical strength at operating temperature) |
- |
|
|
|
| 14.2 (Construction) |
- |
|
|
|
| 10.0 (Electrical strength at operating temperature) |
- |
|
|
|
| 14.3 (Construction) |
- |
|
|
|
| 14.4 (Construction) |
- |
|
|
|
| 10.0 (Electrical strength at operating temperature) |
- |
|
|
|
| 14.5 (Construction) |
- |
|
|
|
| 10.0 (Electrical strength at operating temperature) |
- |
|
|
|
| 14.5 (Construction) |
- |
|
|
|
| 11.1 (Moisture resistance) |
- |
|
|
|
| 14.6 (Construction) |
- |
|
|
|
| 11.1 (Moisture resistance) |
- |
|
|
|
| 14.6 (Construction) |
- |
|
|
|
| 14.7 (Construction) |
- |
|
|
|
| 11.1 (Moisture resistance) |
- |
|
|
|
| 14.7 (Construction) |
- |
|
|
|
| 14.8 (Construction) |
- |
|
|
|
| 11.1 (Moisture resistance) |
- |
|
|
|
| 11.2 (Resistant to humidity) |
- |
|
|
|
| 14.9 (Construction) |
- |
|
|
|
| 14.1 (Construction) |
- |
|
|
|
| 11.2 (Resistant to humidity) |
- |
|
|
|
| 14.1 (Construction) |
- |
|
|
|
| 14.11 (Construction) |
- |
|
|
|
| 12.0 (Electric strength at room temperature) |
- |
|
|
|
| 13.0 (Mechanical strength) |
- |
|
|
|
| 14.11 (Construction) |
- |
|
|
|
| 14.1 (Construction) |
- |
|
|
|
| 14.11 (Construction) |
- |
|
|
|
| 14.1 (Construction) |
- |
|
|
|
| 14.12 (Construction) |
- |
|
|
|
| 14.13 (Construction) |
- |
|
|
|
| 14.2 (Construction) |
- |
|
|
|
| 14.3 (Construction) |
- |
|
|
|
| 14.13 (Construction) |
- |
|
|
|
| 14.4 (Construction) |
- |
|
|
|
| 14.5 (Construction) |
- |
|
|
|
| 14.13 (Construction) |
- |
|
|
|
| 14.6 (Construction) |
- |
|
|
|
| 14.7 (Construction) |
- |
|
|
|
| 14.14 (Construction) |
- |
|
|
|
| 14.7 (Construction) |
- |
|
|
|
| 14.8 (Construction) |
- |
|
|
|
| 14.9 (Construction) |
- |
|
|
|
| 15.1 (Protection of cords and wires) |
- |
|
|
|
| 14.1 (Construction) |
- |
|
|
|
| 14.11 (Construction) |
- |
|
|
|
| 15.2 (Protection of cords and wires) |
- |
|
|
|
| 14.11 (Construction) |
- |
|
|
|
| 15.2 (Protection of cords and wires) |
- |
|
|
|
| 17 Table-1 (Screws and connections) |
- |
|
|
|
| 17 Table-1 (Nominal daimeter of screws made of insulating material) |
- |
|
|
|
| 18.0 (Clearance and creepage distance) |
- |
|
|
|
| 19.1 (Ball pressure test IEC 60695-10-2) |
- |
|
|
|
| 7.0 (Marking and instructions) |
- |
|
|
|
| 14.12 (Construction) |
- |
|
|
|
| 7.0 (Marking and instructions) |
- |
|
|
|
| 14.13 (Construction) |
- |
|
|
|
| 14.14 (Construction) |
- |
|
|
|
| 15.1 (Protection of cords and wires) |
- |
|
|
|
| 15.2 (Protection of cords and wires) |
- |
|
|
|
| 17 Table-1 (Screws and connections) |
- |
|
|
|
| 17 Table-1 (Nominal daimeter of screws made of insulating material) |
- |
|
|
|
| 18.0 (Clearance and creepage distance) |
- |
|
|
|
| 19.1 (Ball pressure test IEC 60695-10-2) |
- |
|
|
|
| 7.0 (Marking and instructions) |
- |
|
|
|
|
- |
- Exclusion
"(i) Components (Cl.16)
(ii) Radiation, toxicity and similar hazards (Cl.20)
(iii) Construction (Cl.14.15)
(iv) Wheeled ride-on toys
(v) Toys incorporating lasers and light-emitting diodes (Annex E) |
| 12937 |
Pulp and Paper Research Institute (PAPRI), Rayagada
| 5169006
| IS 11688 (1999) |
Newsprint - Specification (First Revision) |
Newsprint - Specification |
7360 View breakup
Rs.7360/- (5% discount to BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.6 of IS 11688(Colour) |
- |
0 |
|
- |
| 4.4.2 of IS 11688-1999(Size) |
- |
0 |
|
- |
| Amndendment 1 of 11688(Ream) |
- |
0 |
|
- |
| Clause 4.2 of IS 11688(Clause 6 of IS 1060 (part 1):1966)(Grammage) |
- |
920 |
|
5% Discount to BIS |
| Clause 4.3 of IS 11688(Clause 7 of IS 1060 (part 1):1966)(Thickness) |
- |
920 |
|
5% Discount to BIS |
| Table 1 of IS 11688 (Clause 13 of IS 1060 (part 2):1960)(Brightness) |
- |
920 |
|
5% Discount to BIS |
| Table 1 of IS 11688 (Clause 16 of IS 1060 (part 1):1966)(Opacity) |
- |
920 |
|
5% Discount to BIS |
| Table 1 of IS 11688 (Clause 3 of IS 9894 : 1981)(Smoothness (Top side)) |
- |
460 |
|
5% Discount to BIS |
| Table 1 of IS 11688 (Clause 3 of IS 9894 : 1981)(Smoothness (Wire side)) |
- |
460 |
|
5% Discount to BIS |
| Table 1 of IS 11688(Clause 13 of IS 4006 (part 1))(Porosity) |
- |
920 |
|
5% Discount to BIS |
| Table 1 of IS 11688 (Clause 12.7 of IS 1060 (part 1):1966)(Tear Index(CD)) |
- |
920 |
|
5% Discount to BIS |
| Table 1 of IS 11688 (Clause 12.4 of IS 1060 (part 1):1966)(Tensile Index(CD)) |
- |
460 |
|
5% Discount to BIS |
| Table 1 of IS 11688 (Clause 12.4 of IS 1060 (part 1):1966)(Tensile Index(MD)) |
- |
460 |
|
5% Discount to BIS |
|
13 Oct, 2027 |
- - |
| 12938 |
Pulp and Paper Research Institute (PAPRI), Rayagada
| 5169006
| IS 3303 (1997) |
Match paper for match box - Specification (Second Revision) |
Match Paper for Match Box - Specification |
3680 View breakup
Rs.3680/- (5% discount to BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.1 of IS 3303 (Clause 6 of IS 1060 (part 1):1966)(Substance) |
- |
920 |
|
5% Discount to BIS |
| Clause 4.3.1.1 of IS 3303 (Clause 12.7 of IS 1060 (part 1):1966)(Tear Index(MD)) |
- |
460 |
|
5% Discount to BIS |
| Clause 4.3.1.1 of IS 3303 (Clause 12.7 of IS 1060 (part 1):1966)(Tear Index(CD)) |
- |
460 |
|
5% Discount to BIS |
| Clause 4.3.1.1 of IS 3303(Clause 12.3 of IS 1060 (part 1):1966)(Tensile Index(MD)) |
- |
460 |
|
5% Discount to BIS |
| Clause 4.3.1.1 of IS 3303(Clause 12.3 of IS 1060 (part 1):1966)(Tensile Index(CD)) |
- |
460 |
|
5% Discount to BIS |
| Clause 4.3.1.1 of IS 3303 (Clause 13.2.2 of IS 1060 (part 1):1966)(Cobb 60) |
- |
920 |
|
5% Discount to BIS |
|
13 Oct, 2027 |
- - |
| 12939 |
Pulp and Paper Research Institute (PAPRI), Rayagada
| 5169006
| IS 3302 (1986) |
Specification for backing sheet for stencil (First Revision) |
Specification For Backing Sheet for Stencil |
4600 View breakup
Rs.4600/- (5% discount to BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 3 of IS 3302 (Clause 6 of IS 1060 (part 1):1966)(Substance) |
- |
920 |
|
5% Discount to BIS |
| Clause 3 of IS 3302 (Clause 12.5.1 of IS 1060 (part 1):1966)(Burst Index) |
- |
920 |
|
5% Discount to BIS |
| Clause 3 of IS 3302 (Clause 12.7 of IS 1060 (part 1):1966)(Tear Index) |
- |
920 |
|
5% Discount to BIS |
| Clause 3 of IS 3302 (Clause 12.3.1 of IS 1060 (part 1):1966)(Tensile Index(MD)) |
- |
460 |
|
5% Discount to BIS |
| Clause 3 of IS 3302 (Clause 12.3.1 of IS 1060 (part 1):1966)(Tensile Index(CD)) |
- |
460 |
|
5% Discount to BIS |
| Clause 3 of IS 3302 (Clause 13.2.3.3 of IS 1060 (part 1):1966)(Cobb 60) |
- |
920 |
|
5% Discount to BIS |
|
13 Oct, 2027 |
- - |
| 12940 |
BIS, Central Laboratory (CL)
| None
| IS 209 (1992) |
Zinc ingot - Specification (Fourth Revision) |
- |
Rs.8430/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause -6, 6.1, 6.2, Table-1 (ZINC) |
- |
|
|
|
| Clause -6, 6.1, 6.2, Table-1 (LEAD) |
- |
|
|
|
| Clause -6, 6.1, 6.2, Table-1 (CADMIUM) |
- |
|
|
|
| Clause -6, 6.1, 6.2, Table-1 (IRON) |
- |
|
|
|
| Clause -6, 6.1, 6.2, Table-1 (TIN) |
- |
|
|
|
| Clause -6, 6.1, 6.2, Table-1 (COPPER) |
- |
|
|
|
| Clause -6, 6.1, 6.2, Table-1 (THALLIUM) |
- |
|
|
|
| Clause -6, 6.1, 6.2, Table-1 (INDIUM) |
- |
|
|
|
| Clause -6, 6.1, 6.2, Table-1 (ALUMINIUM) |
- |
|
|
|
| Clause -6, 6.1, 6.2, Table-1 (TOTAL IMPURITIES) |
- |
|
|
|
| 7 (Free from defects) |
- |
|
|
|
| 8 (Mass) |
- |
|
|
|
|
- |
- Material Grade/ designation as per IS 209 may please be declared |
| 12941 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 1065 : Part 1 (2019) |
Stable bleaching powder - Specification: Part 1 household and industrial use (Third Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2 (Description) |
- |
|
|
|
| 5.2.1 (Description) |
- |
|
|
|
| 5.3 Table-1 i (Available chlorine) |
- |
|
|
|
| 5.3 Table-1 ii (Stability, loss of
Chlorine on the basis of
initial available chlorine ) |
- |
|
|
|
| 5.3 Table-1 iiii (Moisture, percent by
mass.
) |
- |
|
|
|
| 5.3 - Table 1 - Sl No - iv (Particle Size (passing through 1.70 mm
IS Sieve) - Annex D) |
- |
|
|
|
| Clause 5.4 (Keeping Quality ) |
- |
|
|
|
| Clause 5.3 Table 1 (Available Chlorine) |
- |
|
|
|
|
- |
- Test facility is complete |
| 12942 |
BIS, Central Laboratory (CL)
| None
| IS 1239 : Part 1 (2004) |
Steel Tubes, Tubulars and Other Wrought Steel Fittings : Part 1 Steel Tubes (BI-LINGUAL) |
- |
Rs. 9200/ View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause - 6.1.1, Table-1 ( CARBON) |
- |
|
|
|
| Clause - 6.1.1, Table-1 (SULPHUR) |
- |
|
|
|
| Clause - 6.1.1, Table-1 (PHOSPHURS) |
- |
|
|
|
| Clause - 6.1.1, Table-1 (MANGANESE) |
- |
|
|
|
| Clause - 6.1.1, Table-1 (SILICON) |
- |
|
|
|
| Clause - 6.1.1, Table-1 ( ALUMINIUM) |
- |
|
|
|
| Clause - 6.1.1, Table-1 (NITROGEN) |
- |
|
|
|
| Cl. 15 (Workmanship) |
- |
|
|
|
| Cl 10.1.1 (Manufacturing ) |
- |
|
|
|
| Cl 8 (Outer Diameter, Thickness & Mass) |
- |
|
|
|
| Cl. 14.1 (Tensile Strength) |
- |
|
|
|
| CL 08 & 09 ("1.Outer dia (04)
2.Thickness (08)") |
- |
|
|
|
| CL 08 & 09 (Minimum Outer dia (04)) |
- |
|
|
|
| CL 08 & 09 (Maximum Outer dia (04)) |
- |
|
|
|
|
- |
- Excluding i) Joint (Cl 10.1)
ii) Leak Proof Test (Cl 13) |
| 12943 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 9873 : Part 2 (2017) |
Safety of toys: Part 2 flammability (Third Revision) |
- |
Rs.2144/ View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2.3-5.3 (Toys to be worn on the head-Beards, moustaches, wigs, etc. made from hair, pile, or material that behaves in a similar manner to hair (e.g. free-hanging ribbons, paper, cloth strands, or other flowing elements), which protrude less than 50 mm and more than 5 mm from the surface of the toy-Duration of the flame after the removal of the test flame) |
- |
|
|
|
| 4.2.3-5.3 (Toys to be worn on the head-Beards, moustaches, wigs, etc. made from hair, pile, or material that behaves in a similar manner to hair (e.g. free-hanging ribbons, paper, cloth strands, or other flowing elements), which protrude less than 50 mm and more than 5 mm from the surface of the toy- maximum distance between the upper edge of the burnt area and the point of application of the test flame) |
- |
|
|
|
| 4.2.4-5.3 (Toys to be worn on the head-Full or partial moulded head masks-Duration of the flame after the removal of the test flame) |
- |
|
|
|
| 4.2.4-5.3 (Toys to be worn on the head-Full or partial moulded head masks-maximum distance between the upper edge of the burnt area and the point of application of the test flame) |
- |
|
|
|
|
- |
- Test facility is complete |
| 12944 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 9873 : Part 4 (2017) |
Safety of toys: Part 4 swings, slides and similar activity toys for indoor and outdoor family domestic use |
- |
Rs.5475/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5.2 (Stability of activity toys with a free height of fall of 600 mm or less) |
- |
|
|
|
| 4.7.1.1 and A.4.7. (Stability of swings and other activity toys with crossbeams) |
- |
|
|
|
| 4.4.1 (Head and neck entrapment) |
- |
|
|
|
| 4.7.3.2 (Toddler swings without a crossbeam) |
- |
|
|
|
| 4.7.4 (Impact from swing elements - swing elements shall not impart an average peak value of acceleration) |
- |
|
|
|
| 4.7.4 (Impact from swing elements - Average surface compression) |
- |
|
|
|
|
- |
- Test facility is complete |
| 12945 |
BIS, Central Laboratory (CL)
| None
| IS 15884 (2010) |
Alternating current direct connected static prepayment meters for active energy (Class 1 And 2) - Specification |
- |
Single phase energy meters-Rs. 16179/- • Three phase en View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1 (By Inspection) |
- |
|
|
|
| 4.1.2 (By Inspection) |
- |
|
|
|
| 4.1.3 (By Inspection) |
- |
|
|
|
| 4.1.4 (By Inspection) |
- |
|
|
|
| 4.2 (Mechanical Requirements) |
- |
|
|
|
| 4.2.1 (By Inspection) |
- |
|
|
|
| 4.2.2 (By Inspection) |
- |
|
|
|
| 4.2.3 (By Inspection) |
- |
|
|
|
| 4.2.4 (IS 13360 (Part 6/Sec 17) for a temperature of 135°C and a pressure of 1.8 MPa (Method A).) |
- |
|
|
|
| 4.2.4 (By Inspection) |
- |
|
|
|
| 4.2.4 (By Inspection) |
- |
|
|
|
| 4.2.5 (shall have a separate cover which can be sealed independently of the meter cover. The terminal cover shall enclose the actual terminals) |
- |
|
|
|
| 4.2.5 (The terminals their fixing screws, a suitable length of external insulated conductor and its insulation shall be enclosed by a cover with a provision for sealing. ) |
- |
|
|
|
| 4.2.5 (The fixing screws used on the terminal cover for fixing and sealing shall be held captive in the terminal cover.) |
- |
|
|
|
| 4.2.5 (When the meter is mounted on the meter board, no access to the terminals shall be possible without breaking the seal of the terminal cover.) |
- |
|
|
|
| 4.2.6 (By measurement) |
- |
|
|
|
| 4.2.6 (By measurement) |
- |
|
|
|
| 4.2.6 (By measurement) |
- |
|
|
|
| 4.2.6 (By measurement) |
- |
|
|
|
| 4.2.7 (Standard test fingure) |
- |
|
|
|
| 4.2.10 (Display of measured values) |
- |
|
|
|
| 4.2.10.1 (By inspection) |
- |
|
|
|
| 4.2.10.1 (By inspection) |
- |
|
|
|
| 4.2.10.1 (By inspection) |
- |
|
|
|
| 4.2.10.2 (By inspection) |
- |
|
|
|
| 4.2.10.3 (By measurement) |
- |
|
|
|
| 4.2.10.4 (By inspection) |
- |
|
|
|
| 4.2.10.5 (By inspection) |
- |
|
|
|
| 4.2.10.5 (By inspection) |
- |
|
|
|
| 4.2.10.5 (By inspection) |
- |
|
|
|
| 4.2.10.5 (By inspection) |
- |
|
|
|
| 4.2.10.5 (By inspection) |
- |
|
|
|
| 4.2.10.6 (By inspection) |
- |
|
|
|
| 4.2.10.7 (By inspection) |
- |
|
|
|
| 4.2.10.7 (By inspection) |
- |
|
|
|
| 4.2.10.8 (Fig. 4, annexure F) |
- |
|
|
|
| 4.2.10.9 (Fig. 5, annexure F) |
- |
|
|
|
| 4.2.11 (By inspection) |
- |
|
|
|
| 4.2.11.1 (By inspection) |
- |
|
|
|
| 4.2.11.1 (By inspection) |
- |
|
|
|
| 4.2.11.1 (By inspection) |
- |
|
|
|
| 4.2.11.1 (By inspection) |
- |
|
|
|
| 4.2.11.1 (By inspection) |
- |
|
|
|
| 4.2.11.1 (By inspection) |
- |
|
|
|
| 4.2.11.1 (By inspection) |
- |
|
|
|
| 4.2.11.1 (By inspection) |
- |
|
|
|
| 4.2.11.1 (By inspection) |
- |
|
|
|
| 4.2.11.1 (By inspection) |
- |
|
|
|
| 4.2.11.1 (By inspection) |
- |
|
|
|
| 4.2.11.1 (By inspection) |
- |
|
|
|
| 4.2.11.1 (By inspection) |
- |
|
|
|
| 4.2.11.1 (By inspection) |
- |
|
|
|
| 4.2.11.1 (By inspection) |
- |
|
|
|
| 4.2.11.1 (By inspection) |
- |
|
|
|
| 5.4.6 (As per IS 2071 (Part1)) |
- |
|
|
|
| 5.4.6.2 (6 KV, As per cl 12.7.6.2 of IS 13779) |
- |
|
|
|
| 5.4.6.2 (12.7.6.2 of IS 13779) |
- |
|
|
|
| 5.4.6.3 (Table 15, power source 500 VA) |
- |
|
|
|
| 5.4.6.4 (500±50V dc) |
- |
|
|
|
| 5.6 (As per cl 4.6) |
- |
|
|
|
| 4.6.1 (As per table 10 & 11, cl 5.6.1) |
- |
|
|
|
| 5.6.5 (As per cl 4.6.5) |
- |
|
|
|
| 5.6.4 (As per cl 4.6.3, Table 13) |
- |
|
|
|
| 5.6.3 (I= open circuit
V= 115% of rated voltage
test period 60 000/k minutes) |
- |
|
|
|
| 5.6.7 (Test shall be carried out at 0.05Ib and Ib at UPF load under reference conditions. Twenty error samples shall be taken at time-intervals of 30 minutes) |
- |
|
|
|
| 4.6.2 (As per table 12) |
- |
|
|
|
| 5.4 (As per 5.6.1) |
- |
|
|
|
| 5.4.1 (As per 4.4.1.1) |
- |
|
|
|
| 4.4.2 (Table 7) |
- |
|
|
|
| 5.4.2 (As per 4.4.2.1) |
- |
|
|
|
| 5.4.3 (Table 8, as per cl4.4.3) |
- |
|
|
|
| 5.4.4 (Table 9, and cl 4.4.4) |
- |
|
|
|
| 5.4.4 (Table 9, and cl 4.4.4) |
- |
|
|
|
| 5.4.5 (As per cl 4.4.5) |
- |
|
|
|
| 5.2 (Test of mechanical requirements) |
- |
|
|
|
| 5.2.3 (As per IS 9000 (Part 8)) |
- |
|
|
|
| 5.2.2 (As per IS 9000 (Part 7/Sec 1)) |
- |
|
|
|
| 5.2.1 (As per cl 12.3.3 of IS 13779) |
- |
|
|
|
| 5.2.5 (Protection against penetration of dust (IP5X)) |
- |
|
|
|
| 5.2.5 (As per IS 12063) |
- |
|
|
|
| 5.2.5 (500 V dc) |
- |
|
|
|
| 5.2.5 (Protection against penetration of water (IP1X)) |
- |
|
|
|
| 5.2.5 (As per IS 12063) |
- |
|
|
|
| 5.2.5 (500 V dc) |
- |
|
|
|
| 5.2.4 (As per IS 11000 (Part 2 / Sec1)) |
- |
|
|
|
| 4.6.3 (Limits of error due to Ambient temperature Variation) |
- |
|
|
|
| 5.8 (Test of Load Switch) |
- |
|
|
|
| 5.9 (Test of Consumption-Based charging function) |
- |
|
|
|
| 5.10 (Test of Time-Based charging function) |
- |
|
|
|
| 4.2.12.3 (Keypad Interface) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.4.6.2 and Table 12 of IS 15884:2010 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
|
- |
- The test facility not available for " (a) Test of power consumption test (b) Radio interference measurement (c) Fast transient bursttest (d)Test of immunity to electrostatic discharges (e) Test of immunity to electromagnetic HF field (f) Dry heat test (g)Cold test (h) Damp heat cycliclest (i) Vibration test (j) Shock lest " |
| 12946 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 4985 (2021) |
UNPLASTICIZED PVC PIPES FOR POTABLE WATER SUPPLIES SPECIFICATION Fourth Revision |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1.1.1 (DIMENSIONS-PIPE-Mean O.D. (Minimum)) |
- |
|
|
|
| 7.1.1.1 (DIMENSIONS-PIPE-Mean O.D. (Mamimum)) |
- |
|
|
|
| 7.1.1.2 (DIMENSIONS-PIPE-O.D. at any Point (Minimum)) |
- |
|
|
|
| 7.1.1.2 (DIMENSIONS-PIPE-O.D. at any Point (Maximum)) |
- |
|
|
|
| 7.1.2.1 (DIMENSIONS-PIPE-Thickness(Minimum)) |
- |
|
|
|
| 7.1.2.1 (DIMENSIONS-PIPE-Thickness(Maximum)) |
- |
|
|
|
| 7.1.2.1 (DIMENSIONS-PIPE-Average Thickness) |
- |
|
|
|
| Cl- 7.2 (Socket length (Take 4 reading & minimum will be reported)) |
- |
|
|
|
| 7.2.1.1-Table 3 (DIMENSIONS-Socket-Sockets for solvent cement jointing-Minimum Length) |
- |
|
|
|
| 7.2.1.2(a)-Table 5 (DIMENSIONS-Sockets for elastomeric sealing ring joints-Minimum depth of engagement) |
- |
|
|
|
| 7.2.1.2-Table 4 (DIMENSIONS-Sockets for elastomeric sealing ring joints-Socket inner Diameter) |
- |
|
|
|
| 10.1 (PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
|
|
|
| 10.2 (PHYSICAL AND CHEMICAL CHARACTERISTICS-Opacity) |
- |
|
|
|
| 10.4 (PHYSICAL AND CHEMICAL CHARACTERISTICS- Reversion Test) |
- |
|
|
|
| 10.5 (PHYSICAL AND CHEMICAL CHARACTERISTICS- Vicat Softening Temperature) |
- |
|
|
|
| 10.6 (PHYSICAL AND CHEMICAL CHARACTERISTICS- Density) |
- |
|
|
|
| 11.1-Table 6 (MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)) |
- |
|
|
|
| 11.1-Table 7 (MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Integral Sealing Ring Sockets) |
- |
|
|
|
| 11.1.1 (MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Plumbing pipes) |
- |
|
|
|
| 11.2 (Resistance to External Blows at 0°C) |
- |
|
|
|
| 7.1.3 (mean outside diameter, outside diameter at
any point, and wall thickness of plumbing pipes) |
- |
|
|
|
| 10.7 (Sulphated Ash Content) |
- |
|
|
|
| 10.3 (Effect on Water Test) |
- |
|
|
|
|
- |
- The following test facilities are not available:
(1) For sizes above 250 mm
(2) Long Term Hydrostatic (Type Test) |
| 12947 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 9873 : Part 1 (2019) |
Safety of toys: Part 1 safety aspects related to mechanical and physical properties (Fourth Revision) |
- |
16,189 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.35.3 - 5.39 (Jaw entrapment in handles and steering wheels-jaw entrapment test) |
- |
|
|
|
| 4.24(b) - 5.18 (Toys containing a heat source-rise in temperature of handles, knobs and similar parts which are likely to be touched by hand-(Parts made of metals)) |
- |
|
|
|
| 4.24(b) - 5.18 (Toys containing a heat source-rise in temperature of handles, knobs and similar parts which are likely to be touched by hand(Parts made of Plastic or wood )) |
- |
|
|
|
| 4.24(b) - 5.18 (Toys containing a heat source-rise in temperature of handles, knobs and similar parts which are likely to be touched by hand(Parts made of glass or porcelain)) |
- |
|
|
|
| 4.24(c) - 5.18 (Toys containing a heat source- rise in temperature of other accessible parts of the toy(Parts made of metals)) |
- |
|
|
|
| 4.24(c) - 5.18 (Toys containing a heat source- rise in temperature of other accessible parts of the toy( Parts made of other materials)) |
- |
|
|
|
| 4.18.4.3 - 5.15.1.3.3 (Projectile toys-Projectile toys without stored energy-Arrows (e.g. bow and arrow set)-kinetic energy per area) |
- |
|
|
|
| 4.18.3(b) - 5.15.1.3.3 (Projectile toys-Projectile toys with stored energy-determination of kinetic energy per area of contact) |
- |
|
|
|
| 4.31.2(a) - 5.32 (Magnets and magnetic components-All other toys with magnets and magnetic components-magnetic flux index) |
- |
|
|
|
| 4.31.2(a) - 5.32 (Magnets and magnetic components-All other toys with magnets and magnetic components-small parts test) |
- |
|
|
|
| 4.4.1 - 5.2 (Small parts-For children under 36 months) |
- |
|
|
|
| 4.4.2 - 5.2 (Small parts-For children 36 months and over but under 72 months
) |
- |
|
|
|
| 4.5.1.2 - 5.3 (Shape, size and strength of certain toys-Squeeze toys, rattles, and certain other toys and components of toys-Test for shape and size of certain toys) |
- |
|
|
|
| 4.5.1.4 - 5.3 (Shape, size and strength of certain toys-Toy fasteners (e.g. nails, bolts, screws, and pegs) with nearly spherical, hemispherical,
or dome-shaped ends intended for children 18 months and over but under 48 months-Test for shape and size of certain toys) |
- |
|
|
|
| 4.5.4 - 5.6 (Shape, size and strength of certain toys- Pre-school play figures-Test for pre-school play figures) |
- |
|
|
|
| 4.5.2 - 5.4 (Shape, size and strength of certain toys-Small balls-Small balls test) |
- |
|
|
|
| 4.5.3 - 5.5 (Shape, size and strength of certain toys-Pompoms-Test for pompoms) |
- |
|
|
|
| 4.11.4(a) - 5.11.4.2 (Cords-Fixed loops and nooses intended for children under 36 months-Test for fixed loops and nooses-Elastic materials) |
- |
|
|
|
| 4.31.2(c ) - 5.31 - 5.24.2 - 5.24.3 - 5.24.5 - 5.24.6.1 - 5.24.6.2 - 5.33 - 5.31 - 5.32 (Magnets and magnetic components-All other toys with magnets and magnetic components-magnetic flux index After Following tests:
-tension test for magnets;
-drop test/tip over test for large and bulky toys;
-torque test;
-tension test, general procedure;
-tension test for seams in soft-filled (stuffed) toys, beanbag-type toys and other similar filled toys, if applicable;
-impact test for magnets;
-compression test;
-tension test for magnets;) |
- |
|
|
|
| 9873 (Part - 3) 4.1 - Table 1 (Selenium (Se) - Cl 7,8,9 ) |
- |
|
|
|
| 9873 (Part - 3) 4.1 - Table 1 (Mercury (Hg) - Cl 7,8,9 ) |
- |
|
|
|
| 9873 (Part - 3) 4.1 - Table 1 (Lead (Pb) - Cl 7,8,9 ) |
- |
|
|
|
| 9873 (Part - 3) 4.1 - Table 1 (Chromium (Cr) - Cl 7,8,9 ) |
- |
|
|
|
| 9873 (Part - 3) 4.1 - Table 1 (Cadmium (Cd) - Cl 7,8,9) |
- |
|
|
|
| 9873 (Part - 3) 4.1 - Table 1 (Barium (Ba) - Cl 7,8,9 ) |
- |
|
|
|
| 9873 (Part - 3) 4.1 - Table 1 (Arsenic (As) - Cl 7,8,9 ) |
- |
|
|
|
| 9873 (Part - 3) 4.1 - Table 1 (Antimony (Sb) - Cl 7,8,9) |
- |
|
|
|
| 9873 (Part - 9) 3 (Vinyl in any part of the toy or childcare article that can be placed in mouth of a child under 4 years of age - a) Di-iso-Nonyl Phthalate (DINP), b) Di-iso-Decyl Phthalate (DIDP), c) Di-n-Octyl Phthalate (DNOP) - IS 9873 Part 6) |
- |
|
|
|
| 9873 (Part - 9) 3 (Vinyl in toys or childcare articles - a) Bis-(2-ethlyhexyl) Phthalates (DEHP), b) Di-Butyl phthalate (DBP), c) Benzyl butyl Phthalate (BBP) - IS 9873 Part 6) |
- |
|
|
|
| 9874 (Part - 4) 4.7.3.1 (Swings intended for children under 36 months) |
- |
|
|
|
| 9874 (Part - 4) 4.8 (Seesaws - The sitting or standing position of the seesaw may swing out of the horizontal) |
- |
|
|
|
|
- |
- Test facility is complete, except phthalates. |
| 12948 |
Pulp and Paper Research Institute (PAPRI), Rayagada
| 5169006
| IS 1848 : Part 2 (2018) |
Writing and printing papers - Specification: Part 2 air mail/manifold, cartridge drawing and cartridge white, duplicating absorbent and duplicating semi - Absorbent and poster machine glazed types (Fifth Revision) |
Writing and Printing Papers-Specification |
10120 View breakup
Rs.10120/- (5% discount to BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2(Substance) |
- |
920 |
|
5% Discount to BIS |
| 4.3(Thickness) |
- |
920 |
|
5% Discount to BIS |
| 4.5(pH) |
- |
920 |
|
5% Discount to BIS |
| 4.6 Table 1 S. No. i)(Manifold CD) |
- |
460 |
|
5% Discount to BIS |
| 4.6 Table 1 ( Manifold MD) |
- |
460 |
|
5% Discount to BIS |
| 4.6 Table 1 (Brightness) |
- |
920 |
|
5% Discount to BIS |
| 4.6 Table 1 (Opacity) |
- |
920 |
|
5% Discount to BIS |
| 4.6 Table 1 (One Minute Cobb Test) |
- |
920 |
|
5% Discount to BIS |
| 4.6 Table 1 (Double Fold CD) |
- |
460 |
|
5% Discount to BIS |
| 4.6 Table 1 (Double Fold MD) |
- |
460 |
|
5% Discount to BIS |
| 4.6 Table 1 (Gloss) |
- |
920 |
|
5% Discount to BIS |
| 4.6 Table 1 (Smoothness) |
- |
920 |
|
5% Discount to BIS |
| 4.6 Table 1 (Tear Index CD) |
- |
460 |
|
5% Discount to BIS |
| 4.6 Table 1(Tear Index MD) |
- |
460 |
|
5% Discount to BIS |
| 4.1(Mechanical pulp for furnish) |
- |
0 |
|
- |
| 4.8.2 (pulp made from materials other than bamboo, hardwoods, softwoods and reed.) |
- |
0 |
|
- |
| 4.8.2(Recycled paper and paper board must be made from waste paper.) |
- |
0 |
|
- |
|
13 Oct, 2027 |
- - |
| 12949 |
Pulp and Paper Research Institute (PAPRI), Rayagada
| 5169006
| IS 1848 : Part 1 (2018) |
Writing and printing papers - Specification: Part 1 account book, azure lead, bond, cream laid and cream wove/printing white/printing coloured/printing offset, printing maplitho, printing white super calendered and typewriting types (Fifth Revision) |
Writing and Printing Papers - Specification |
11620 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.4.2(Substance, Ref IS 1763) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.5(pH) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. i(Tensile index, Account book-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. i(Tensile index, Account book-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. i(Brightness ISO, Account book) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. i(Opacity, Account book) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. i(One minute cobb test, Account book) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. i(Double fold, Account book-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. i(Double fold, Account book-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. i(Gloss, Account book) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. i(Wax pick, Account book) |
- |
1500 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. i(Smoothness(Bendtsen),Account book) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. i(Tear index, Account book-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. i(Tear index, Account book-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. ii(Tensile index, Azure laid-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. ii(Tensile index, Azure laid-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. ii(Brightness ISO, Azure laid) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. ii(Opacity,Azure laid) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. ii(One minute cobb test, Azure laid) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. ii(Double fold, Azure laid-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. ii(Double fold, Azure laid-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. ii(Gloss, Azure laid) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. ii(Wax pick, Azure laid) |
- |
1500 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. ii(Smoothness(Bendtsen),Azure laid) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. ii(Tear index, Azure laid-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. ii(Tear index, Azure laid-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iii(Tensile index, Bond-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iii(Tensile index, Bond-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iii(Brightness ISO, Bond) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iii(Opacity, Bond) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iii(One minute cobb test, Bond) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iii(Double fold, Bond-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iii(Double fold, Bond-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iii(Gloss, Bond) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iii(Wax pick, Bond) |
- |
1500 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iii(Smoothness(Bendtsen),Bond) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iii(Tear index, Bond-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iii(Tear index, Bond-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iv(Tensile index, Cream laid and cream wove/printing white/printing coloured/printing offset-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iv(Tensile index, Cream laid and cream wove/printing white/printing coloured/printing offset-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iv(Brightness ISO, Cream laid and cream wove/printing white/printing coloured/printing offset) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iv(Opacity, Cream laid and cream wove/printing white/printing coloured/printing offset) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iv(One minute cobb test, Cream laid and cream wove/printing white/printing coloured/printing offset) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iv(Double fold, Cream laid and cream wove/printing white/printing coloured/printing offset-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iv(Double fold, Cream laid and cream wove/printing white/printing coloured/printing offset-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iv(Gloss, Cream laid and cream wove/printing white/printing coloured/printing offset) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iv(Wax pick, Cream laid and cream wove/printing white/printing coloured/printing offset) |
- |
1500 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iv(Smoothness bendtsen, Cream laid and cream wove/printing white/printing coloured/printing offset) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iv(Tear index, Cream laid and cream wove/printing white/printing coloured/printing offset-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. iv(Tear index, Cream laid and cream wove/printing white/printing coloured/printing offset-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. v(Tensile index, Printing Maplitho-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. v(Tensile index, Printing Maplitho-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. v(Brightness ISO, Printing Maplitho) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. v(Opacity, Printing Maplitho) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. v(One minute cobb test, Printing Maplitho) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. v(Double fold, Printing Maplitho-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. v(Double fold, Printing Maplitho-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. v(Gloss, Printing Maplitho) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. v(Wax pick, Printing Maplitho) |
- |
1500 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. v(Smoothness bendtsen, Printing Maplitho) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. v(Tear index, Printing Maplitho-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. v(Tear index, Printing Maplitho-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vi(Tensile index, Printing White Super Calendered-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vi(Tensile index, Printing White Super Calendered-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vi(Brightness ISO, Printing White Super Calendered) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vi(Opacity, Printing White Super Calendered) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vi(One minute cobb test, Printing White Super Calendered) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vi(Double fold, Printing White Super Calendered-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vi(Double fold, Printing White Super Calendered-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vi(Gloss, Printing White Super Calendered) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vi(Wax pick, Printing White Super Calendered) |
- |
1500 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vi(Smoothness bendtsen, Printing White Super Calendered) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vi(Tear index, Printing White Super Calendered-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vi(Tear index, Printing White Super Calendered-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vi(Tensile index, Typewriting-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vii(Tensile index, Typewriting-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vii(Brightness ISO, Typewriting) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vii(Opacity, Typewriting) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vii(One minute cobb test, Typewriting) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vii(Double fold, Typewriting-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vii(Double fold, Typewriting-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vii(Gloss, Typewriting) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vii(Wax pick, Typewriting) |
- |
1500 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vii(Smoothness bendtsen, Typewriting) |
- |
920 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vii(Tear index, Typewriting-CD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vii(Tear index, Typewriting-MD) |
- |
460 |
|
5% discount to BIS |
| Cl. 4.6,4.7,6.2, Table No. 1, Sl no. vii(Tear index, Typewriting-MD) |
- |
460 |
|
5% discount to BIS |
|
13 Oct, 2027 |
- - |
| 12950 |
Pulp and Paper Research Institute (PAPRI), Rayagada
| 5169006
| IS 6956 (2001) |
Cover paper - Specification (First Revision) |
Cover Paper |
10700 View breakup
Rs.9780/- (5% discount to BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.3(Grarnmage-As per 6 of IS 1060 (Part 1)-Further a mean of 10 test results shall not
vary from nominal grarnmage by more than ±4 percent.) |
- |
920 |
|
5% Discount to BIS |
| 4.3(Grarnmage-As per 6 of IS 1060 (Part 1)- no single test result shall vary by more than *6 percent from nominal) |
- |
920 |
|
5% Discount to BIS |
| 4.2,Table1 (One minute Cobb test (Test method Column 4 and 5 of table1)) |
- |
920 |
|
5% Discount to BIS |
| 4.2,Table1 (Smoothness (Bendtsen)-(Test method Column 4 and 5 of table1)) |
- |
920 |
|
5% Discount to BIS |
| 4.2,Table1 (Burst Index-(Test method Column 4 and 5 of table1)) |
- |
920 |
|
5% Discount to BIS |
| 4.2,Table1 (Ph(Test method Column 4 and 5 of table1)) |
- |
920 |
|
5% Discount to BIS |
| 4.2,Table1 (Folding endurance-MD-(Test method Column 4 and 5 of table1)) |
- |
460 |
|
5% Discount to BIS |
| 4.2,Table1 (Folding endurance-CD-(Test method Column 4 and 5 of table1)) |
- |
460 |
|
5% Discount to BIS |
| 4.2,Table1 (Tensile Index-CD(Test method Column 4 and 5 of table1)) |
- |
460 |
|
5% Discount to BIS |
| 4.2,Table1 (Tensile Index-MD(Test method Column 4 and 5 of table1)) |
- |
460 |
|
5% Discount to BIS |
| 4.2,Table1 (Brightness(For white paper only) -(Test method Column 4 and 5 of table1)) |
- |
920 |
|
5% Discount to BIS |
| 4.2,Table1 (Opacity, (Test method Column 4 and 5 of table1)) |
- |
920 |
|
5% Discount to BIS |
| 4.2,Table1 (Bending stiffness index,-CD-(Test method Column 4 and 5 of table1)) |
- |
460 |
|
5% Discount to BIS |
| 4.2,Table1 (Bending stiffness index,-MD-(Test method Column 4 and 5 of table1)) |
- |
460 |
|
5% Discount to BIS |
| 4.2,Table1 (Wax pick-(Test method Column 4 and 5 of table1)) |
- |
1500 |
|
5% Discount to BIS |
|
13 Oct, 2027 |
- - |
| 12951 |
Central Institute of Mining & Fuel Research (CSIR-CIMFR), Dhanbad
| 5127821
| IS/IEC 60079 : Part 1 (2014) |
Explosive Atmospheres - Part 1 : Equipment Protection by Flameproof Enclosures "d" |
- |
71560 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 15.2.1(Tests of ability of the enclosure to withstand pressure) |
- |
10890 |
|
Test Charges vary according to the volume of the enclosure and the Test Gas(Gas group). |
| 15.2.2(Determination of explosion pressure (reference pressure)) |
- |
8470 |
|
Test Charges vary according to the volume of the enclosure and the Test Gas(Gas group). |
| 15.2.3.2(Overpressure test – First method (static)) |
- |
2420 |
|
Test Charges vary according to the volume of the enclosure and the Test Gas(Gas group). |
| C.3.1(Observation) |
- |
41310 |
|
- |
| 15.3.1(Test for non-transmission of an internal ignition) |
- |
8470 |
|
- |
| C.3.3.2(Pressure) |
- |
8470 |
|
- |
| C.3.4.3(Pressure) |
- |
8470 |
|
- |
|
- |
- - |
| 12952 |
Pulp and Paper Research Institute (PAPRI), Rayagada
| 5169006
| IS 14490 (2018) |
Plain copier paper - Specification (First Revision) |
Plain Copier paper |
11620 View breakup
Rs.11620/- (5% discount to BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 5.5, Table 1, Sl. No. (vii), (a)(Tensile Index (CD)) |
- |
0 |
|
- |
| Cl. 5.5, Table 1, Sl. No. (vii), (a)(Tensile Index (CD)) |
- |
920 |
|
5% Discount to BIS |
| Cl. 5.5, Table 1, Sl. No. (vii), (a)(Tensile Index (CD)) |
- |
920 |
|
5% Discount to BIS |
| Cl. 5.5, Table 1, Sl. No. (vii), (a)(Tensile Index (CD)) |
- |
920 |
|
5% Discount to BIS |
| Cl. 5.5, Table 1, Sl. No. (vii), (a)(Tensile Index (CD)) |
- |
920 |
|
5% Discount to BIS |
| Cl. 5.5, Table 1, Sl. No. (vii), (a)(Tensile Index (CD)) |
- |
920 |
|
5% Discount to BIS |
| Cl. 5.5, Table 1, Sl. No. (vii), (a)(Tensile Index (CD)) |
- |
920 |
|
5% Discount to BIS |
| Cl. 5.5, Table 1, Sl. No. (vii), (a)(Tensile Index (CD)) |
- |
920 |
|
5% Discount to BIS |
| Cl. 5.5, Table 1, Sl. No. (vii), (a)(Tensile Index (CD)) |
- |
920 |
|
5% Discount to BIS |
| Cl. 5.5, Table 1, Sl. No. (vii), (a)(Tensile Index (CD)) |
- |
1500 |
|
5% Discount to BIS |
| Cl. 5.5, Table 1, Sl. No. (vii), (a)(Tensile Index (CD)) |
- |
460 |
|
5% Discount to BIS |
| Cl. 5.5, Table 1, Sl. No. (vii), (a)(Tensile Index (CD)) |
- |
460 |
|
5% Discount to BIS |
| Cl. 5.5, Table 1, Sl. No. (vii), (a)(Tensile Index (CD)) |
- |
460 |
|
5% Discount to BIS |
| Cl. 5.5, Table 1, Sl. No. (vii), (a)(Tensile Index (CD)) |
- |
460 |
|
5% Discount to BIS |
| Cl. 5.5, Table 1, Sl. No. (vii), (a)(Tensile Index (CD)) |
- |
460 |
|
5% Discount to BIS |
| Cl. 5.5, Table 1, Sl. No. (vii), (a)(Tensile Index (CD)) |
- |
460 |
|
5% Discount to BIS |
|
13 Oct, 2027 |
- - |
| 12953 |
POWERONIC TEST & RESEARCH CENTRE PRIVATE LIMITED, GREATER NOIDA
| 8170206
| IS 302 : Part 2 : Sec 30 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 30 room heaters (First Revision) |
Room Heater |
17000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.8 & IS:302-1:2008(Protection Against Access to Live Parts) |
- |
500 |
|
- |
| Cl.10 & IS:302-1:2008(Power Input and Current) |
- |
300 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.13 & IS:302-1:2008(Leakage Current & Electric Strength at operating temp. ) |
- |
500 |
|
- |
| Cl.14 & IS:302-1:2008(Transient Over Voltages) |
- |
500 |
|
- |
| Cl.15 & IS: 302-1:2008(Moisture Resistance
) |
- |
500 |
|
- |
| Cl.15.3 of IS 302-1:200(Moisture Resistance
) |
- |
500 |
|
- |
| Cl.16 & IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
500 |
|
- |
| Cl.17 & IS:302-1:2008(Over load Protection of Transformers and Associated Circuits ) |
- |
500 |
|
- |
| Cl.18 (Endurance. ) |
- |
1000 |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.102(Abnormal Operation.) |
- |
0 |
|
- |
| Cl.19.103(Abnormal Operation.) |
- |
0 |
|
- |
| Cl.19.104(Abnormal Operation.) |
- |
0 |
|
- |
| Cl.19.105(Abnormal Operation.) |
- |
0 |
|
- |
| Cl.19.106(Abnormal Operation.) |
- |
0 |
|
- |
| Cl.19.107(Abnormal Operation.) |
- |
0 |
|
- |
| Table 8 of IS 302-1:2008(Abnormal Operation.) |
- |
0 |
|
- |
| Cl.19.108(Abnormal Operation.) |
- |
0 |
|
- |
| Cl.19.109(Abnormal Operation.) |
- |
0 |
|
- |
| Cl.19.110(Abnormal Operation.) |
- |
0 |
|
- |
| Cl.19.111(Abnormal Operation.) |
- |
0 |
|
- |
| Cl.19.112(Abnormal Operation.) |
- |
0 |
|
- |
| Cl.19.113(Abnormal Operation.) |
- |
0 |
|
- |
| Cl.19.114(Abnormal Operation.) |
- |
0 |
|
- |
| Cl.20 & IS:302-1:2008(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| Cl.21 & IS:302-1:2008)(Mechanical Strength.) |
- |
250 |
|
- |
| Cl.21.2 of IS 302-1:2008(Mechanical Strength.) |
- |
250 |
|
- |
| Cl.21.103(Mechanical Strength.) |
- |
250 |
|
- |
| Cl.22.1 of IS 302-1:2008(Construction) |
- |
50 |
|
- |
| Cl.22.5 of IS 302-1:2008(Construction) |
- |
50 |
|
- |
| Cl.22.6 of IS 302-1:2008(Construction) |
- |
50 |
|
- |
| Cl.22.7 of IS 302-1:2008(Construction) |
- |
50 |
|
- |
| Cl.22.8 of IS 302-1:2008(Construction) |
- |
50 |
|
- |
| Cl.22.9 of IS 302-1:2008(Construction) |
- |
50 |
|
- |
| Cl.22.11(Construction) |
- |
50 |
|
- |
| Cl.22.12 of IS 302-1:2008(Construction) |
- |
50 |
|
- |
| Cl.22.13 of IS 302-1:2008(Construction) |
- |
50 |
|
- |
| Cl.22.14 of IS 302-1:2008(Construction) |
- |
50 |
|
- |
| Cl.22.15 of IS 302-1:2008(Construction) |
- |
50 |
|
- |
| Cl.22.18 of IS 302-1:2008(Construction) |
- |
50 |
|
- |
| Cl.22.20 of IS 302-1:2008(Construction) |
- |
50 |
|
- |
| Cl.22.21 of IS 302-1:2008(Construction) |
- |
50 |
|
- |
| Cl.23 & IS:302-1:2008(Internal Wiring
) |
- |
250 |
|
- |
| Cl.23.4 & Cl.29 of 302-1:2008(Internal Wiring
) |
- |
250 |
|
- |
| Cl.23.5 of 302-1:2008(Internal Wiring
) |
- |
250 |
|
- |
| Cl.23.7 of 302-1:2008(Internal Wiring
) |
- |
250 |
|
- |
| Cl.24.1 of 302-1:2008(Component) |
- |
50 |
|
- |
| Cl.24.1.3 (Component) |
- |
50 |
|
- |
| C.24.1.4(Component) |
- |
50 |
|
- |
| Cl.24.10(Component) |
- |
50 |
|
- |
| C.24.2 of 302-1:2008(Component) |
- |
50 |
|
- |
| Cl.25.1 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
50 |
|
- |
| Cl. 25.2 of IS 3021:2008(Supply Connection and External Flexible Cords ) |
- |
100 |
|
- |
| Cl. 25.3 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
100 |
|
- |
| Cl. 25.4 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
100 |
|
- |
| Cl.25.5 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
100 |
|
- |
| Cl.25.6 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
100 |
|
- |
| Cl.25.7.(Supply Connection and External Flexible Cords ) |
- |
100 |
|
- |
| Cl.25.8(Supply Connection and External Flexible Cords ) |
- |
100 |
|
- |
| Cl. 25.9(Supply Connection and External Flexible Cords ) |
- |
100 |
|
- |
| Cl.25.10 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
100 |
|
- |
| Cl. 25.11(Supply Connection and External Flexible Cords ) |
- |
100 |
|
- |
| Cl. 25.12(Supply Connection and External Flexible Cords ) |
- |
100 |
|
- |
| Cl. 25.13(Supply Connection and External Flexible Cords ) |
- |
100 |
|
- |
| Cl.25.14 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
100 |
|
- |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
100 |
|
- |
| Cl.25.17 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
100 |
|
- |
| Cl.25.18(Supply Connection and External Flexible Cords ) |
- |
100 |
|
- |
| Cl.25.20(Supply Connection and External Flexible Cords ) |
- |
100 |
|
- |
| Cl.26.1 of IS 302-1:2008(Terminal for External Conductors
) |
- |
250 |
|
- |
| Cl.26.10 of IS 302-1:2008(Terminal for External Conductors
) |
- |
250 |
|
- |
| Cl.26.11 of IS 302-1:2008(Terminal for External Conductors
) |
- |
250 |
|
- |
| Cl.27.1 of 302-1:2008(Provision for Earthing.) |
- |
200 |
|
- |
| Cl.27.5 of 302-1:2008(Provision for Earthing.) |
- |
50 |
|
- |
| Cl.28 of 302-1:2008(Screws and Connections.) |
- |
250 |
|
- |
| Cl.29 & IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation) |
- |
500 |
|
- |
| Cl.30 & IS:302-1:2008(Resistance to Heat and Fire) |
- |
2000 |
|
- |
| Cl.30.2 of 302-1:2008(Resistance to Heat and Fire : Resistance to fire) |
- |
0 |
|
- |
| Cl.31 of IS:302-1:2008(Resistance to Rusting.) |
- |
1000 |
|
- |
| Cl.30.1 of IS:302-1:2008(Resistance to Heat and Fire: Resistance to heat. ) |
- |
0 |
|
- |
| Cl.31 & IS:302-1:2008(Resistance to Rusting.) |
- |
0 |
|
- |
| Cl.32 & IS:302-1:2008(Radition,Toxicity and similar Hazards.) |
- |
1000 |
|
- |
| Cl.6 (Classification) |
- |
250 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
250 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
|
11 Apr, 2028 |
- EXCLUSIONS: EMI/EMC tests (Electrostatic discharges,
radiant fields, fast transient bursts, voltage surges, injected
current, voltage dip and interruption, mains signals)
(Cl.19.11.4.1 to 19.11.4.7), Components (Capacitors for
radio interference suppression, isolating transformer,
coupler) (Cl.24.1.1, 24.1.2, 24.1.5 |
| 12954 |
POWERONIC TEST & RESEARCH CENTRE PRIVATE LIMITED, GREATER NOIDA
| 8170206
| IS 302 : Part 2 : Sec 14 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision) |
Electric kitchen Machines |
14500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
500 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
500 |
|
- |
| 11(Heating, IS 302-1) |
- |
1000 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
- |
| 14(Transient Over Voltages, IS 302-1) |
- |
500 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
500 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
500 |
|
- |
| 19.7(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
50 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
50 |
|
- |
| 20.103(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.104(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.105(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.106(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.107(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.108(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.109(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.110(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.111(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.113(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.114(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.115(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 20.116(Stability & Mechanical Hazards) |
- |
50 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
250 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
250 |
|
- |
| 22.101(Construction) |
- |
500 |
|
- |
| 22.102(Construction) |
- |
500 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
| 23.10(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
| 24.1(Components, IS 302-1) |
- |
250 |
|
- |
| 24.2(Components, IS 302-1) |
- |
250 |
|
- |
| 24.5(Components, IS 302-1) |
- |
250 |
|
- |
| 24.6(Components, IS 302-1) |
- |
250 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1 |
|
- |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
500 |
|
- |
| 27(Provision for Earthing, IS 302-1) |
- |
100 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
100 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
100 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
100 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
100 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
500 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
250 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
250 |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
500 |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
500 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
500 |
|
- |
| 32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
1500 |
|
- |
|
11 Apr, 2028 |
- EXCLUSIONS: EMI/EMC tests (Electrostatic discharges,
radiant fields, fast transient bursts, voltage surges, injected
current, voltage dip and interruption, mains signals)
(Cl.19.11.4.1 to 19.11.4.7), Components (Capacitors for
radio interference suppression, isolating transformer,
coupler) (Cl.24.1.1, 24.1.2, 24.1.5) |
| 12955 |
POWERONIC TEST & RESEARCH CENTRE PRIVATE LIMITED, GREATER NOIDA
| 8170206
| IS 3854 (1997) |
Switches for domestic and similar purposes - Specification (Second Revision) |
rated voltage not exceeding 440 V and rated current not |
10500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Rating) |
- |
500 |
|
- |
| 6(Rating) |
- |
500 |
|
- |
| 7(Classification) |
- |
500 |
|
- |
| 8.2(Marking) |
- |
100 |
|
- |
| 8.3(Marking) |
- |
100 |
|
- |
| 8.4(Marking) |
- |
100 |
|
- |
| 8.5(Marking) |
- |
150 |
|
- |
| 8.6(Marking) |
- |
150 |
|
- |
| 8.7(Marking) |
- |
150 |
|
- |
| 8.8(Marking) |
- |
150 |
|
- |
| 10(Protection against Electric Shock) |
- |
1000 |
|
- |
| 11.1(Provision for earthing) |
- |
1000 |
|
- |
| 12(Terminals) |
- |
100 |
|
- |
| 12.2.1(Terminals) |
- |
100 |
|
- |
| 12.2.2(Connection of conductor) |
- |
500 |
|
- |
| 12.2.3(Mechanical strength of terminals) |
- |
500 |
|
- |
| 12.2.4(Resistance to corrosion) |
- |
500 |
|
- |
| 12.2.5(Undue damage to conductor) |
- |
500 |
|
- |
| 12.2.7(Insertion of conductor) |
- |
100 |
|
- |
| 12.2.9(Locking against accidental loosening) |
- |
100 |
|
- |
| 12.2.11(Distance between screw and conductor) |
- |
100 |
|
- |
| 12.3.2(Screwless terminals) |
- |
100 |
|
- |
| 12.3.3(Connectin of conductor) |
- |
100 |
|
- |
| 12.3.4(Material of terminals) |
- |
100 |
|
- |
| 12.3.5(Clamping) |
- |
100 |
|
- |
| 12.3.7(v) Interconnection of conductors [Cl. 12.3.7]) |
- |
100 |
|
- |
| 12.3.11(vi) Electrical & Thermal Stresses [Cl 12.3.11]) |
- |
1000 |
|
- |
| 12.3.12(vii) Deflection Stresses [Cl. 12.3.12]) |
- |
150 |
|
- |
| 13.1(a) Insulating lining, barriers and the like [Cl 13.1]) |
- |
100 |
|
- |
| 13.2(b) Construction of switch [Cl 13.2]) |
- |
100 |
|
- |
| 13.2(i) Installation Test) |
- |
100 |
|
- |
| 13.3(c) Covers,cover plates and actuating members [Cl 13.3]) |
- |
100 |
|
- |
| 13.4(d) Ordinary switches [Cl 13.4]) |
- |
100 |
|
- |
| 13.5(e) Rotary switches [Cl 13.5]) |
- |
100 |
|
- |
| 13.6(f) Screws and other means [Cl 13.6]) |
- |
100 |
|
- |
| 13.7(g) Combination of switches or switches and socket outlets [Cl 13.7]) |
- |
100 |
|
- |
| 13.8(h) Assessories combined with switches [Cl. 13.8]) |
- |
100 |
|
- |
| 13.9(j) Switches other than ordinary switches [Cl. 13.9]) |
- |
100 |
|
- |
| 13.1(k) Switches to be installed in a box [Cl. 13.10]) |
- |
100 |
|
- |
| 13.11(l) Surface type switches other than ordinary switch [Cl. 13.11]) |
- |
100 |
|
- |
| 13.12, 13.13, 13.14(m) Inlet opening [Cl. 13.12.13.13 & 13.14]) |
- |
100 |
|
- |
| 13.15(q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
100 |
|
- |
| 14.4(Mechanism) |
- |
100 |
|
- |
| 15.1(Resistance to Ageing, to Harmful Ingress of water and to Humidity [Cl. 15]: Resistance to Ageing, [Cl. 15.1]) |
- |
100 |
|
- |
| 15.2(b)Resistance to Harmful ingress of water [Cl. 15.2]) |
- |
100 |
|
- |
| 15.3(c) Resistance to Humidity [Cl. 15.3]) |
- |
100 |
|
- |
| 16.1(Insulation resistance [Cl. 16.1]) |
- |
100 |
|
- |
| 16.2( Electric Strength [Cl. 16.2]) |
- |
100 |
|
- |
| 16.3(Insulation
resistance and electric strength
) |
- |
100 |
|
- |
| 17(Temperature- rise [Cl. 17]) |
- |
100 |
|
- |
| 18(Marking and breaking Capacity[Cl. 18]) |
- |
100 |
|
- |
| 19(Normal Operation [Cl. 19] a) General & Operation) |
- |
100 |
|
- |
| 19(b) Electric Strength) |
- |
100 |
|
- |
| 19(c)Temperature-rise ) |
- |
10 |
|
- |
| 20(Mechanical Strength Test [Cl. 20]) |
- |
10 |
|
- |
| 21(Resistance to Heat [Cl.21]) |
- |
10 |
|
- |
| 22(Screw, Current Carrying Part And Connection [Cl.22]) |
- |
10 |
|
- |
| 22.1(i) Screw & Nuts [Cl.22.1]) |
- |
10 |
|
- |
| 22.4(ii) Screw & rivets [Cl . 22.4]) |
- |
10 |
|
- |
| 22.3(iii) Electrical Connections [Cl.22.3]) |
- |
10 |
|
- |
| 22.5(iv) Current carrying part [Cl.22.5]) |
- |
10 |
|
- |
| 23.1(Creepage distances,
clearances & distance through
sealing compound
) |
- |
10 |
|
- |
| 24.1.1(Resistance to Abnormal Heat & Fire [Cl.24.1] [Glow Wire Test] [Cl.24.1.1]) |
- |
500 |
|
- |
| 24.2(Resistance to tracking [For Switch other than ordinary] [Cl.24.2]) |
- |
500 |
|
- |
| 19.2(Normal operation) |
- |
10 |
|
- |
| 25 of IS 3854 : 1997(Resistance to rusting) |
- |
500 |
|
- |
|
11 Apr, 2028 |
- - |
| 12956 |
POWERONIC TEST & RESEARCH CENTRE PRIVATE LIMITED, GREATER NOIDA
| 8170206
| IS 1293 (2019) |
Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) |
up to 250 v and rated current up to including 16 Amp |
17500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Ratings) |
- |
10 |
|
- |
| 7.1.1(Accessories Classification) |
- |
10 |
|
- |
| 7.1.2(Accessories Classification) |
- |
10 |
|
- |
| 7.1.3(Accessories Classification) |
- |
10 |
|
- |
| 7.1.4(Accessories Classification) |
- |
10 |
|
- |
| 7.1.5(Accessories Classification) |
- |
10 |
|
- |
| 8.1(MARKING) |
- |
10 |
|
- |
| 8.8(MARKING) |
- |
10 |
|
- |
| 8.9(MARKING) |
- |
10 |
|
- |
| 9.1(CHECKING OF DIMENSIONS) |
- |
10 |
|
- |
| 9.2(CHECKING OF DIMENSIONS) |
- |
10 |
|
- |
| 10.1(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
250 |
|
- |
| 10.1(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
250 |
|
- |
| 10.3(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
10 |
|
- |
| 10.4(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
10 |
|
- |
| 10.5(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
10 |
|
- |
| 10.6(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
10 |
|
- |
| 10.7(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
10 |
|
- |
| 11.1(PROVISIONS FOR EARTHING) |
- |
10 |
|
- |
| 11.2(PROVISIONS FOR EARTHING) |
- |
10 |
|
- |
| 12.1.1(TERMINALS) |
- |
10 |
|
- |
| 12.1.2(TERMINALS) |
- |
10 |
|
- |
| 12.2.2(TERMINALS) |
- |
10 |
|
- |
| 12.2.3(TERMINALS) |
- |
10 |
|
- |
| 12.2.4(TERMINALS) |
- |
10 |
|
- |
| 12.2.5(TERMINALS) |
- |
10 |
|
- |
| 12.2.6(TERMINALS) |
- |
10 |
|
- |
| 12.2.7(TERMINALS) |
- |
10 |
|
- |
| 12.2.8(TERMINALS) |
- |
10 |
|
- |
| 12.3.9(TERMINALS) |
- |
10 |
|
- |
| 12.3.10(TERMINALS) |
- |
10 |
|
- |
| 12.3.11(TERMINALS) |
- |
10 |
|
- |
| 12.3.12(TERMINALS) |
- |
10 |
|
- |
| 13.1(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.2(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.3(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.4(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.5(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.6(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.7(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.8(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.9(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.1(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.11(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.12(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.13(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.15(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.16(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.17(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.18(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.19(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.21(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.22(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 13.23(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
10 |
|
- |
| 14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.3(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.4(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.5(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.16(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.7(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.8(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.9(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.11(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.12(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.13(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.14(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.15(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.17(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.18(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.19(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.21(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.22(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.23(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.24(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.25(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 14.26(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
10 |
|
- |
| 15(INTERLOCKED SOCKET-OUTLETS) |
- |
100 |
|
- |
| 16.1(RESISTANCE TO AGEING,) |
- |
250 |
|
- |
| 16.2(RESISTANCE TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
250 |
|
- |
| 16.3(Resistance to Humidity) |
- |
250 |
|
- |
| 17.1(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
250 |
|
- |
| 17.2(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
350 |
|
- |
| 17.3(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
400 |
|
- |
| 18(OPERATION OF EARTHING CONTACTS) |
- |
500 |
|
- |
| 19(TEMPERATURE RISE) |
- |
500 |
|
- |
| 20(BREAKING CAPACITY) |
- |
500 |
|
- |
| 21(NORMAL OPERATION) |
- |
500 |
|
- |
| 22.1(Verification of the Maximum Withdrawal Force) |
- |
250 |
|
- |
| 22.2(Verification of Minimum Withdrawal Force) |
- |
250 |
|
- |
| 23.1(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
350 |
|
- |
| 23.3(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
350 |
|
- |
| 23.4(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
300 |
|
- |
| 24.1(MECHANICAL STRENGTH
For all kinds of fixed socket-outlets
) |
- |
100 |
|
- |
| 24.1(MECHANICAL STRENGTH
For portable multiple and combined socket outlets
with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
100 |
|
- |
| 24.1(MECHANICAL STRENGTH
For surface mounting boxes) |
- |
100 |
|
- |
| 24.2(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
100 |
|
- |
| 24.2(MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
100 |
|
- |
| 24.2(MECHANICAL STRENGTH
For plug
1) with enclosures, covers and bodies other than elastomeric or thermoplastic material) |
- |
200 |
|
- |
| 24.2(MECHANICAL STRENGTH
For plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
200 |
|
- |
| 24.3(MECHANICAL STRENGTH
for fixed socket-outlets with a main part intended to be mounted directly on a surface) |
- |
200 |
|
- |
| 24.4(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
200 |
|
- |
| 24.4(MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
200 |
|
- |
| 24.4(MECHANICAL STRENGTH
For Plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
10 |
|
- |
| 24.5(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
100 |
|
- |
| 24.5(MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
100 |
|
- |
| 24.5(MECHANICAL STRENGTH
For Plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
100 |
|
- |
| 24.6(MECHANICAL STRENGTH
For screwed glands of accessories having an IP code higher than IP20) |
- |
100 |
|
- |
| 24.7(MECHANICAL STRENGTH
For plug pins provided with insulating sleeves) |
- |
100 |
|
- |
| 24.8(MECHANICAL STRENGTH
For shuttered socket-outlets) |
- |
100 |
|
- |
| 24.9(MECHANICAL STRENGTH
For portable multiple and combined socket outlets
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
100 |
|
- |
| 24.9(MECHANICAL STRENGTH
For portable multiple and combined socket outlets
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
100 |
|
- |
| 24.1(MECHANICAL STRENGTH
For Plug
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
100 |
|
- |
| 24.1(MECHANICAL STRENGTH
For Plug
(1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
100 |
|
- |
| 24.11(MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
100 |
|
- |
| 24.12(MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
100 |
|
- |
| 24.13(MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
100 |
|
- |
| 24.14.1(MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
100 |
|
- |
| 24.14.2(MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
100 |
|
- |
| 24.14.3(MECHANICAL STRENGTH
For plugs and portable socket-outlets) |
- |
100 |
|
- |
| 25.1(RESISTANCE TO HEAT
Accessories and surface mounting boxes) |
- |
100 |
|
- |
| 25.2(RESISTANCE TO HEAT
Parts of insulating material necessary to retain
current-carrying parts of the earthing circuit in position,
as well as parts of the front surface zone of thermoplastic material) |
- |
100 |
|
- |
| 25.3(RESISTANCE TO HEAT
Parts of insulating material not necessary to retain current-carrying parts and parts of the earthing circuit in position, even though they are in contact with them) |
- |
250 |
|
- |
| 25.4(RESISTANCE TO HEAT
) |
- |
250 |
|
- |
| 26.2(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
10 |
|
- |
| 26.1(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
| 26.3(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
| 26.4(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
| 26.5(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
| 26.6(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
300 |
|
- |
| 26.7(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
200 |
|
- |
| 27.1(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
250 |
|
- |
| 27.2(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
2 |
|
- |
| 27.3(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
50 |
|
- |
| 28.1.1(Resistance to Abnormal Heat and to Fire
Glow-Wire Test) |
- |
3000 |
|
- |
| 28.1.2(Resistance to Abnormal Heat and to Fire
for plugs with pins provided with insulating sleeves) |
- |
1000 |
|
- |
| 28.2(Resistance to Tracking
For accessories other than IP code higher than IPX0 parts of insulating material retaining live parts in position) |
- |
1000 |
|
- |
| 29(RESISTANCE TO RUSTING) |
- |
1000 |
|
- |
| 30.1(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Pressure Test at High Temperature) |
- |
250 |
|
- |
| 30.2(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Static Damp Heat Test) |
- |
250 |
|
- |
| 30.3(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Tests at Low Temperature) |
- |
250 |
|
- |
| 30.4(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Impact Test at Low Temperature) |
- |
250 |
|
- |
|
11 Apr, 2028 |
- - |
| 12957 |
BIS, Central Laboratory (CL)
| None
| IS 10805 (1986) |
Specification for foot - Valves, reflux valves or non - Return valves and bore valves to be used in suction lines of agricultural pumping systems (First Revision) |
- |
Rs.4500.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| (Cl. 2 Table 1) (Nominal Size) |
- |
|
|
|
| (Cl. 2 Table 1) (Dimensions) |
- |
|
|
|
| (Cl. 2 Table 1) (Dimensions) |
- |
|
|
|
| (Cl. 4) (Requirements) |
- |
|
|
|
| (Cl. 4) (Requirements) |
- |
|
|
|
| (Cl. 5) (Coating) |
- |
|
|
|
| 6.1.1 (Seat test) |
- |
|
|
|
| 6.1.2 (Housing test) |
- |
|
|
|
| 6.2 (K-Value Test for Foot-Valves and Bore Valves) |
- |
|
|
|
| (Cl. 4) (Requirements) |
- |
|
|
|
|
- |
- Excluding K value and thread checking facility |
| 12958 |
POWERONIC TEST & RESEARCH CENTRE PRIVATE LIMITED, GREATER NOIDA
| 8170206
| IS 9857 (1990) |
Welding cables - Specification (First Revision) |
450/750 Volts |
17000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.1 a) 1)(Annealing test - IS 10810: Part 1) |
- |
500 |
|
- |
| 10.1 a) 2)(Conductor resistance tes - IS 10810 : Part 5) |
- |
500 |
|
- |
| Table 1 (Thickness of covering) |
- |
500 |
|
- |
| 10.1 c) 1)(Physical tests for
covering : Tensile strength ) |
- |
500 |
|
- |
| 10.1 c) 1)(Physical tests for
covering : Elongation at break ) |
- |
500 |
|
- |
| 10.1 c) 2)(Physical tests for
covering - Ageing in Air oven : Tensile strength ) |
- |
500 |
|
- |
| 10.1 c) 2)(Physical tests for
covering -Ageing in Air oven : Elongation at break ) |
- |
500 |
|
- |
| 10.1 c) 2)(Physical tests for
covering - Ageing in Air oven : Tensile strength variation) |
- |
500 |
|
- |
| 10.1 c) 2)(Physical tests for
covering -Ageing in Air oven : Elongation variation at break ) |
- |
500 |
|
- |
| Table 2(Ageing in air bomb - Elongation) |
- |
1000 |
|
- |
| Table 2(Ageing in air bomb - Tensile strength ) |
- |
1000 |
|
- |
| Table 2(Oil resistance - Elongation) |
- |
1000 |
|
- |
| Table 2(Oil resistance - Tensile strength ) |
- |
1000 |
|
- |
| 10.1 c) 4)(Physical tests for
covering - Oil Resistance : Tensile strength variation ) |
- |
1000 |
|
- |
| 10.1 c) 4)(Physical tests for
covering - Oil Resistance : Elongation variation at break ) |
- |
1000 |
|
- |
| 10.1 c) 5)(Hot set test ) |
- |
500 |
|
- |
| 11.1(High Voltage Test ( Water Immersion
Test )) |
- |
2000 |
|
- |
| 11.3(Static Flexibility Test) |
- |
500 |
|
- |
| 11.4(Flammability Test) |
- |
2000 |
|
- |
| 4(Conductor : Material ) |
- |
0 |
|
- |
| 5(SEPARATOR) |
- |
0 |
|
- |
| 6(COVERING) |
- |
0 |
|
- |
| 7(CONDUCTOR : CONSTRUCTION ) |
- |
0 |
|
- |
| 8(S E P A R A T O R) |
- |
0 |
|
- |
| 9.1(C O V E R I N G : Application ) |
- |
0 |
|
- |
| 9.2(T h i c k n e s s o f C o v e r i n g) |
- |
0 |
|
- |
| 9.3(T o l e r a n c e on Thickness o f C o v e r i n g) |
- |
0 |
|
- |
| 9.4(A p p l i c a t i o n of C o v e r i n g) |
- |
0 |
|
- |
| 9.5(Colour of C o v e r i n g) |
- |
0 |
|
- |
| 12.1(Manufacturer's Identification) |
- |
0 |
|
- |
| 12.2(Cable Identification) |
- |
0 |
|
- |
| 12.3(Cable Code) |
- |
0 |
|
- |
| 13.2(Marking) |
- |
0 |
|
- |
| Table 4(Copper purity test) |
- |
1500 |
|
- |
|
11 Apr, 2028 |
- - |
| 12959 |
Central Power Research Institute (CPRI), Bangalore
| 6101024
| IS 13340 (1993) |
Power capacitors of self-Healing type for AC power systems having rated voltage up to 650 V - Specification |
- |
1100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 18.1(AC VOLTAGE TEST BETWEEN
TERMINALS
: Routiue Test) |
- |
1100 |
|
Test charges are dependent on the kvar of the test sample |
| 19.1(Voltage test between terminals and container : routine test) |
- |
850 |
|
- |
|
31 Dec, 2026 |
- - |
| 12960 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 412 (1975) |
Specification for expanded metal steel sheets for general purposes (Second Revision) |
- |
675 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 3.2 (Sulphur) |
- |
|
|
|
| Cl. 3.2 (Phosphorus) |
- |
|
|
|
| Cl. 3.2 (Nitrogen) |
- |
|
|
|
|
- |
- Test facility is complete |