Search by IS Number
Reset
14118 Results
S.No. Lab Name Osl Code Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
13651 BIS, Eastern Regional Laboratory (ERL) None IS 204 : Part 1 (1991) Tower bolts - Specification: Part 1 ferrous metals (Fifth Revision) All grades (except tests mentioned in remarks) Rs.2100.00. View breakup
-
- -
Chem-Facility not available for micro alloying elements, for cast iron- facility not available for Sulphur
13652 BIS, Central Laboratory (CL) None IS 8446 (1991) Pesticide - Carbendazim (MBC) WP - Specification (First Revision) - Rs 4700/- View breakup
-
- -
-
13653 BIS, Western Regional Laboratory (WRL) None IS 7887 (1992) Mild steel wire rod for general engineering purposes - Specification (First Revision) - Rs.7200/- View breakup
-
- -
Test facilities are not available for the following: 1. Chemical composition (Al)
13654 BIS, Central Laboratory (CL) None IS 3074 (2013) Steel tubes for automotive purposes - Specification (Third Revision) - 4200 View breakup
Rs.3750/- for CDS-1, CDS-2, CDS-3, CDS-4, CDS-5, Rs.4720/- for CDS-6, Rs.6750/- for CDS-7 & CDS-8, Rs.6750/- for CDS-9. Rs.3750/- for ERW/HFIW (ERW-1, ERW-2, ERW-3). Rs.4200/- for Mechanical testing charges.
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm; Excluding -; Leak tightness Test (Cl 23)
13655 BIS, Western Regional Laboratory (WRL) None IS 7834 : Part 3 (1987) injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 3 Specific requirements for 90 degree elbows - Rs.2700/- View breakup
-
- -
The following test facilities are not available: 6.3 Effect on water
13656 BIS, Eastern Regional Laboratory (ERL) None IS 9962 (1981) Specification for steel wire for needles all size and grade - View breakup
-
- -
Grade,size and finish to be declared
13657 BIS, Western Regional Laboratory (WRL) None IS 7834 : Part 1 (1987) injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 1 General requirements - Rs.2400/- View breakup
-
- -
The following test facilities are not available: 6.3 Effect on water
13658 BIS, Northern Regional Laboratory (NRL) None IS 5312 : Part 1 (2004) Swing Check Type Reflux (Non-Return] Valves for Water Works Purposes - Part 1 : Single-Door Pattern - Rs 5700/- View breakup
-
- -
All test excluding HST for size above 300 mm, Facility for chemical testing is not available
13659 BIS, Northern Regional Laboratory (NRL) None IS 781 (1984) Specification for cast copper alloy screw down bib taps and stop valves for water services (Third Revision) - Rs.2700/- View breakup
-
- -
Facility for chemical testing is not available
13660 BIS, Western Regional Laboratory (WRL) None IS 15490 (2017) Seamless steel cylinders for on - Board storage of compressed natural gas as a fuel for automotive vehicles - Specification (First Revision) - 16297 View breakup
-
- -
Test facilities are not available for the following: 1. Cr, Ni, Mo, V, Al, N, B, Zr 2.Pressure cycling Test 3. Base check 4. Hydrostatic Stretch Test 5. Leakage Test 6.Neck threads 7. Surface Defects 8. Verticality 9. Hydraulic Bursting Test 10. Sulphide Stress Cracking Resistance Test 11 Ultrasonic testing 12 Leakage before breakage test 13 Bonfire test Remark: Prepared piece for tensile (2 nos), bend (4 nos) and impact (3 nos)
13661 BIS, Western Regional Laboratory (WRL) None IS 7285 : Part 1 (2018) Refillable seamless steel gas cylinders - Specification: Part 1 normalized steel cylinders (Fourth Revision) - - View breakup
-
- -
Test facilities are not available for the following: 1. Cr, Ni, Mo, V, Al, N, B, Zr 2.Pressure cycling Test 3. Base check 4. Hydrostatic Stretch Test 5. Leakage Test 6.Neck threads 7. Surface Defects 8. Verticality 9. Hydraulic Bursting Test 10. Sulphide Stress Cracking Resistance Test 11 Ultrasonic testing Remark: Prepared piece for tensile (2 nos), bend (4 nos) and impact (3 nos)
13662 BIS, Central Laboratory (CL) None IS 3039 (1988) Specification for structural steel for construction of hulls of ships (Second Revision) - - View breakup
-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
13663 BIS, Western Regional Laboratory (WRL) None IS 7142 (1995) Welded low carbon steel cylinders for low pressure liquifiable gases not exceeding 5 litre water capacity - Specification (First Revision) - Rs. 9552/- View breakup
-
- -
Test facilities are not available for the following: 1. Thread gauges
13664 BIS, Western Regional Laboratory (WRL) None IS 7092 : Part 2 (1987) Specification for aluminium alloy tube for irrigation purposes: Part 2 extruded tube (Second Revision) - Rs 11230/- View breakup
-
- -
" 1. Tensile Test 2. Hydrostatic Machine "
13665 BIS, Western Regional Laboratory (WRL) None IS 6603 (2001) Stainless steel bars and flats - Specification (First Revision) - - View breakup
-
- -
Test facilities are not available for the following: 1. Ti, Nb, Mo, Cu 2. Corrosion resistance Remark: Prepared piece of impact (3 nos)
13666 BIS, Central Laboratory (CL) None IS 2831 (2012) Carbon steel cast billet ingots, billets, blooms and slabs for re-rolling into structural steel (Ordinary Quality) - Specification (Fourth Revision) - Rs. 4500/- View breakup
Excluding Macro examination and Sulphur print
- -
"Grade designation to be declared. Microalloying element/type of killing (element)/any other element to be declared. Sample size shall be minimum dia> 3mm and thickness > 0.8 mm; "
13667 BIS, Western Regional Laboratory (WRL) None IS 6529 (1996) Stainless steel blooms, billets and slabs for forging - Specification (First Revision) - - View breakup
-
- -
Test facilities are not available for the following: 1. Ni, Cr, Mo, Ti, Nb, N 2. Corrosion Test
13668 BIS, Northern Regional Laboratory (NRL) None IS 6006 (2014) Uncoated stress relieved strand for prestressed concrete - Specification (Second Revision) - Rs 4035/- Excluding Proof Stress and Relaxation Test View breakup
-
- -
Test Facility Complete for Chemical Except Stress relaxation test, Proof stress
13669 BIS, Northern Regional Laboratory (NRL) None IS 3575 (1993) Bitumen drums - Specification (Third Revision) - Please see remarks. View breakup
Rs. 1800/- and Material testing charges as per relevant referred Iss
- -
Except air pressure test and Microalloying elements
13670 BIS, Western Regional Laboratory (WRL) None IS 14333 (1996) High Density Polyethylene Pipe For Sewerage - - 3900 View breakup
-
- -
The following test facilities are not available: (1)Internal Pressure creep rupture test (2)Tensile Strength for Butt-fusion (3) Slow Crack Growth rate test (4) Depth of strip (5) Overall Migration (7) Carbon Black content (8) For Size above 250 mm
13671 BIS, Western Regional Laboratory (WRL) None IS 6240 (2008) Hot rolled steel plate (Up To 6 Mm) sheet and strip for the manufacture of low pressure liquefiable gas cylinders (Fourth Revision) - 9710 View breakup
Rs.9710/- excluding Erichsen cupping test.
- -
Test facilities are not available for the following: 1. Al, N, Micro alloying element 2. Erichsen Cuppling Machine
13672 BIS, Western Regional Laboratory (WRL) None IS 11513 (2017) Hot rolled carbon steel strip for cold rolling purposes - Specification (Second Revision) - - View breakup
-
- -
Test facilities are not available for the following: 1. Micro alloy, N, Al, Cu, Cr, Mo, Ni
13673 BIS, Northern Regional Laboratory (NRL) None IS 6911 (2017) Stainless steel plate, sheet and strip - Specification (Second Revision) - - View breakup
-
- -
Facility for chemical testing is not available, Erichsen Cupping(Cl11), Corrosion(Cl 12), Proof stress
13674 BIS, Western Regional Laboratory (WRL) None IS 4923 (2017) Hollow steel sections for structural use - Specification (Third Revision) - - View breakup
-
- -
Test facilities are not available for the following: 1. Cu
13675 BIS, Central Laboratory (CL) None IS 7231 (1994) plastic flushing cisterns for waterclosets and urinals - Rs.8100/- View breakup
-
- -
-
13676 BIS, Western Regional Laboratory (WRL) None IS 4270 (2001) Steel tubes used for water wells specification (Third Revision) - Rs.7500/- View breakup
-
- -
Except Hydrostatic test (Cl.8)
13677 BIS, Northern Regional Laboratory (NRL) None IS 903 (1993) Specification for Fire Hose Delivery Couplings, Branch Pipe, Nozzles And Nozzle Spanner - Specificaion - Rs 3600/ View breakup
-
- -
Facility for chemical testing is not available
13678 BIS, Northern Regional Laboratory (NRL) None IS 3502 (2009) Steel chequered plates (Third Revision) - 2985 View breakup
-
- -
-
13679 BIS, Western Regional Laboratory (WRL) None IS 10748 (2004) Hot - Rolled steel strip for welded tubes and pipes - Specification (Second Revision) - Please see remarks View breakup
i) For grade 1,2&3 = 3716 /-, Rounded off to Rs.3750/- ii) For grade 4,5 & 6 including Micro alloying elements = 6728/-, Rounded off to Rs.6750/- Remarks: Testing chargesfor each of the elements other than Table-1 (Silicon, Aluminum, Nitrogen etc.) will be Rs.1004/-
- -
Test facilities are not available for the following: 1. V, Nb, Ti, Al, Nitrogen, Mn, Cr, Mo, V, Ni, Cu
13680 BIS, Northern Regional Laboratory (NRL) None IS 1038 (1983) Specification For Steel Doors, Windows And Ventilators - 3000 View breakup
Hence complete testing charges for the product are Rs.3000.00
- -
Complete

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.

Contact for any query/support: supportlims@bis.gov.in