| 15481 |
BIS, Central Laboratory (CL)
| None
| IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Conductor - Material) |
- |
|
|
|
| 4.1 (Tensile test (for Al)-Before Stranding) |
- |
|
|
|
| 4.1 (Tensile test (for Al)- After Stranding) |
- |
|
|
|
| 4.1 (Annealing test (for copper)) |
- |
|
|
|
| 4.1 (Wrapping test (for Al)) |
- |
|
|
|
| 4.2 (Conductor resistance test) |
- |
|
|
|
| 5.1 (Insulation) |
- |
|
|
|
| 5.2 (Application ) |
- |
|
|
|
| 5.3 (Thickness of Insulation) |
- |
|
|
|
| 6.1 (Filler) |
- |
|
|
|
| 6.2 (Filler) |
- |
|
|
|
| 7 (Binder Tape) |
- |
|
|
|
| 8.1 (Sheath Material ) |
- |
|
|
|
| 8.3 (Thickness of Sheath) |
- |
|
|
|
| 9 (Overall dimensions) |
- |
|
|
|
| 9.1 (Ovality) |
- |
|
|
|
| 10.1 (HV (water immersion)) |
- |
|
|
|
| 10.2 (HV (room temperature)) |
- |
|
|
|
| 10.4 (Flammability test-Burning after flame removal) |
- |
|
|
|
| 10.4 (Flammability test- Unaffected portion) |
- |
|
|
|
| 10.9 (Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
|
|
|
| 10.11 (Per sulphate test (for tinned Cu cable only)) |
- |
|
|
|
| 11 (Identification) |
- |
|
|
|
| 11.1 (Durability) |
- |
|
|
|
| 11.2 (Legibility) |
- |
|
|
|
| 12 (CONSTRUCTION Core Identification) |
- |
|
|
|
| Table 1 iii) c) 1) (Tensile strength (Without ageing)) |
- |
|
|
|
| Table 1 iii) c) 1) (Elongation (Without ageing)) |
- |
|
|
|
| Table 1 iii) c) 2) (Loss of mass- Insulation ) |
- |
|
|
|
| Table 1 iii) c) 3) (Tensile strength (After ageing)) |
- |
|
|
|
| Table 1 iii) c) 3) (TS variation) |
- |
|
|
|
| Table 1 iii) c) 3) (Elongation (After ageing)) |
- |
|
|
|
| Table 1 iii) c) 3) (Elongation variation) |
- |
|
|
|
| Table 1 iii) c) 4) (Shrinkage-Insulation) |
- |
|
|
|
| Table 1 iii) c) 4) (Cracks Observed) |
- |
|
|
|
| Table 1 iii) c) 5) (Heat shock-Insulation ) |
- |
|
|
|
| Table 1 iii) c) 6) (Hot deformation - Indentation depth- Insulation) |
- |
|
|
|
| Table 1 iii) c) 7) (Thermal stability- Insulation ) |
- |
|
|
|
| Table 1 iii) c) 8) (Cold bend for insulation) |
- |
|
|
|
| Table 1 iii) c) 9) (Cold impact for insulation) |
- |
|
|
|
| Table 1 iii) d) 1) (Sheath -Tensile strength (Without ageing)) |
- |
|
|
|
| Table 1 iii) d) 1) (Sheath- Elongation (Without ageing)) |
- |
|
|
|
| Table 1 iii) d) 2) (Loss of mass- Sheath ) |
- |
|
|
|
| Table 1 iii) d) 3) (Sheath- Tensile strength (After ageing)) |
- |
|
|
|
| Table 1 iii) d) 3) (Sheath- TS variation) |
- |
|
|
|
| Table 1 iii) d) 3) (Sheath- Elongation (After ageing)) |
- |
|
|
|
| Table 1 iii) d) 3) (Sheath- Elongation variation) |
- |
|
|
|
| Table 1 iii) d) 4) (Shrinkage- Sheath ) |
- |
|
|
|
| Table 1 iii) d) 4) (Cracks Observed) |
- |
|
|
|
| Table 1 iii) d) 5) (Heat shock-Sheath ) |
- |
|
|
|
| Table 1 iii) d) 6) (Hot deformation -Indentation depth - Sheath ) |
- |
|
|
|
| Table 1 iii) d) 7) (Thermal stability- Sheath ) |
- |
|
|
|
| Table 1 iii) d) 8) (Cold bend for sheath) |
- |
|
|
|
| Table 1 iii) d) 9) (Cold impact for sheath) |
- |
|
|
|
| table 1 e) 3) (Volume Resistivity - Room temp ) |
- |
|
|
|
| table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
|
|
|
| table 1 e) 3) (IR constant- Room temp ) |
- |
|
|
|
| table 1 e) 3) (IR constant- max. Temp) |
- |
|
|
|
| Table 1 iii) c) 8) (Cold bend for insulation) |
- |
|
|
|
| Table 1 iii) c) 9) (Cold impact for insulation) |
- |
|
|
|
| Table 1 iii) d) 8) (Cold bend for sheath) |
- |
|
|
|
| Table 1 iii) d) 9) (Cold impact for sheath) |
- |
|
|
|
| Table 1 (Category Code) |
- |
|
|
|
| 10.11 (Persulphate Test ) |
- |
|
|
|
| 4.1 (Conductor - Material) |
- |
|
|
|
| 4.1 (Conductor - Material) |
- |
|
|
|
| 4.1 (Conductor - Material) |
- |
|
|
|
| 8 (SHEATH) |
- |
|
|
|
| 18 (SINGLE AND MULTICORE CIRCULAR PVC INSULATED
AND SHEATHED CABLES WITH RIGID CONDUCTOR (CLASS 1 AND CLASS 2) FOR GENERAL PURPOSE ) FOR MAXIMUM CONDUCTOR TEMPERATURE (70°C OR 85°C)) |
- |
|
|
|
| 4.1 (Material) |
- |
|
|
|
| (4.3 of IS 8130:2013) (Form of Conductor) |
- |
|
|
|
| ( 4.4.1 of IS 8130:2013) (Joints in Conductor) |
- |
|
|
|
| (4.4.2 of IS 8130:2013) (Joints in Conductor Solid Conductors (Aluminium Conductors only)) |
- |
|
|
|
| (Cl.6.1.1 of IS 8130:2013) (Solid Conductor (Class 1)) |
- |
|
|
|
| (Cl.6.1.2 of IS 8130:2013) (Solid Conductor (Class 1)) |
- |
|
|
|
| (Cl.6.1.3 of IS 8130:2013) (Solid Conductor (Class 1)) |
- |
|
|
|
| (6.2.1 of IS 8130:2013) (Stranded Circular Non-compacted Conductors (Class 2)) |
- |
|
|
|
| (6.2.2 of IS 8130:2013) (Stranded Circular Non-compacted Conductors (Class 2)) |
- |
|
|
|
| (6.2.3 of IS 8130:2013) (Stranded Circular Non-compacted Conductors (Class 2)) |
- |
|
|
|
| (6.3.1 of IS 8130:2013) (Stranded Compacted Circular Conductors and Shaped Conductors (Class 2)) |
- |
|
|
|
| (6.3.2 of IS 8130:2013) (Stranded Compacted Circular Conductors and Shaped Conductors (Class 2)) |
- |
|
|
|
| (6.3.3 of IS 8130:2013) (Stranded Compacted Circular Conductors and Shaped Conductors (Class 2)) |
- |
|
|
|
| ( 6.4.1 of IS 8130:2013) (Flexible Conductors (Class 5)) |
- |
|
|
|
| (6.4.2 of IS 8130:2013) (Flexible Conductors (Class 5)) |
- |
|
|
|
| ( 6.4.3 of IS 8130:2013) (Flexible Conductors (Class 5)) |
- |
|
|
|
| Cl.19.1.4 (Assembly of Cores) |
- |
|
|
|
| Cl. 8.2 (Application of Sheath) |
- |
|
|
|
|
- |
- Test facility not available for FR, FR-LSH category. |
| 15482 |
BIS, Central Laboratory (CL)
| None
| IS 269 (2015) |
Ordinary portland cement - Specification (Sixth Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1 Table-2 viii (Alkali content) |
- |
|
|
|
| 6.1 Table-2 vii (Chloride content) |
- |
|
|
|
| 6.1 Table-2 vi (Loss on ignition) |
- |
|
|
|
| 6.1 Table-2 v (Total Sulphur Content calculated as Sulphuric Anhydride) |
- |
|
|
|
| 6.1 Table-2 iv (Magnesia) |
- |
|
|
|
| 6 - Table - 1 i (Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
| 6.1 Table-2 iii. (Insoluble residue) |
- |
|
|
|
| 6.1 Table-2 ii. (Ratio of percentage of alumina to that of iron oxide) |
- |
|
|
|
| 6.1 Table-2 viii (Alkali content) |
- |
|
|
|
| 6.1 Table-2 vii (Chloride content) |
- |
|
|
|
| 6.1 Table-2 vi (Loss on ignition) |
- |
|
|
|
| 6.1 Table-2 v (Total Sulphur Content calculated as Sulphuric Anhydride) |
- |
|
|
|
| 6.1 Table-2 iv (Magnesia) |
- |
|
|
|
| 6 - Table - 1 i (Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
| 6.1 Table-2 iii. (Insoluble residue) |
- |
|
|
|
| 6.1 Table-2 ii. (Ratio of percentage of alumina to that of iron oxide) |
- |
|
|
|
| 7 Table-3 iv c (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 Table-3 iv b (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 Table-3 iv a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 Table-3 iii b (Setting Time Final) |
- |
|
|
|
| 7 Table-3 iii a (Setting Time Initial) |
- |
|
|
|
| 7 Table-3 ii b (Expansion by Autoclave) |
- |
|
|
|
| 7 Table-3 ii a (Expansion by Le Chatelier) |
- |
|
|
|
| 7 Table-3 i. (Fineness) |
- |
|
|
|
|
- |
- Excluding Table 2,Clause 6.1 ,sl. no.(viii) , alkali content; |
| 15483 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 269 (2015) |
Ordinary portland cement - Specification (Sixth Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 Table-3 i. (Fineness) |
- |
|
|
|
| 7 Table-3 i. (Fineness) |
- |
|
|
|
| 7 Table-3 ii a (Expansion by Le Chatelier) |
- |
|
|
|
| 7 Table-3 ii b (Expansion by Autoclave) |
- |
|
|
|
| 7 Table-3 iii a (Setting Time Initial) |
- |
|
|
|
| 7 Table-3 iii b (Setting Time Final) |
- |
|
|
|
| 7 Table-3 iv a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 Table-3 iv b (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 Table-3 iv c (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.1 Table-2 vi (Loss on ignition) |
- |
|
|
|
| 6.1 Table-2 viii (Alkali content) |
- |
|
|
|
| 6.1 Table-2 vii (Chloride content) |
- |
|
|
|
| 6.1 Table-2 v (Total Sulphur Content calculated as Sulphuric Anhydride) |
- |
|
|
|
| 6.1 Table-2 iv (Magnesia) |
- |
|
|
|
| 6.1 Table-2 iii. (Insoluble residue) |
- |
|
|
|
| 6.1 Table-2 ii. (Ratio of percentage of alumina to that of iron oxide) |
- |
|
|
|
| 6 - Table - 1 i (Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
|
- |
- Test Facility is complete for Chemical.
Test Facility is complete except Transverse Strength Test |
| 15484 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 12818 (2010) |
Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) |
- |
Rs.6450.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.6 (Vicat Softening Temperature
IS 12235 (Part 2).) |
- |
|
|
|
| 9.3 (Density
IS 12235 (Part 14)) |
- |
|
|
|
| 9.1 ( Visual Appearance) |
- |
|
|
|
| 7.2 and Table 5, 6 & 7
Fig 1B (Wall thickness, Min) |
- |
|
|
|
| 7.1, 7.2 and Table 5, 6 & 7 Fig 1B (Mean outside dia over connection,mm (Take 4 reading and maximum valu reported)) |
- |
|
|
|
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B (Outer Diameter at any point ) |
- |
|
|
|
| 7.2 and Table 5, 6 & 7
Fig 1B (Mean Outer Diameter of Pipe, Min) |
- |
|
|
|
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B (Mean Outer Diameter of Pipe) |
- |
|
|
|
| 7.2 and Table 5, 6 & 7
Fig 1B (Mean Outer Diameter of Pipe , Max) |
- |
|
|
|
| 7.1, 7.2 and Table 5, 6 & 7 Fig 1B (Outer Diameter at any point , Min) |
- |
|
|
|
| 8.4 (Sealing rings - Hardness) |
- |
|
|
|
| 9.1 ( Visual Appearance) |
- |
|
|
|
| 5 (COLOUR) |
- |
|
|
|
| 8.4.1 and Table 13
Fig 3B & 4B (Dimensions of sealing elements) |
- |
|
|
|
| 7.4 Table 8 & 9
Fig 1 (Effective length, l2) |
- |
|
|
|
| 7.4 Table 8 & 9
Fig 1 (Segmental length, l3) |
- |
|
|
|
| 7.4 Table 8 & 9 Fig 1 (Segmental length,mm for socket (average of 4.0)) |
- |
|
|
|
| 7.4 Table 8 & 9 Fig 1 (Segmental length for Spigot (average of 4.0)) |
- |
|
|
|
| 7.3.1 (No.of Ribs) |
- |
|
|
|
| 7.3.2 (Rib height) |
- |
|
|
|
|
- |
- " 6 mts, 2 Gaskets and 5 Hardness button
Excluding Excl. Tensile test, reistance to external blows at 0°C , Effect on Water, thread gauges |
| 15485 |
BIS, Central Laboratory (CL)
| None
| IS 14151 : Part 2 (2008) |
Irrigation equipment - Sprinkler pipes - Specification: Part 2 quick coupled polyethylene pipes and fittings (Second Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.2.1 (Visual and Workmanship Requirement) |
- |
|
|
|
| 4.2.7 (1 Dimensions of Quick Coupled Pipes and Fittings) |
- |
|
|
|
|
- |
- - |
| 15486 |
BIS, Central Laboratory (CL)
| None
| IS 1489 (Part 1) (2015) |
Portland pozzolana cement - Specification: Part 1 fly Ash Based |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 - Table - 1 v (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 iv (Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 i (Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 iii (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 ii (Magnesia - Cl 7.2 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 vi ( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
|
|
|
| 7 -Table 2- vi (Drying Shrinkage- IS 4031 Part 10) |
- |
|
|
|
| 7 -Table 2- iv- c (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 -Table 2- iv- b (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 -Table 2- iv- a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 -Table 2-iii- b (Setting Time Final- 4031 Part 5) |
- |
|
|
|
| 7 -Table 2- iii- a (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
| 7 -Table 2- ii- b (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
| 7 -Table 2- ii- a (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
| 7 -Table 2- i (Fineness 4031 Part 2) |
- |
|
|
|
|
- |
- Excluding Table 1,Clause 6 ,sl. no.(vi) , alkali content; |
| 15487 |
BIS, Central Laboratory (CL)
| None
| IS 4985 (2021) |
UNPLASTICIZED PVC PIPES FOR POTABLE WATER SUPPLIES SPECIFICATION Fourth Revision |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.1 (Colour) |
- |
|
|
|
| 10.1 (Surface Finish) |
- |
|
|
|
| 7.2.1.1 Table3 (Angle of taper (Note-1)) |
- |
|
|
|
| 5 (CLASSIFICATION OF PIPES) |
- |
|
|
|
| 7.1.1.1 (DIMENSIONS-PIPE-Mean O.D. (Minimum)) |
- |
|
|
|
| 7.1.1.1 (DIMENSIONS-PIPE-Mean O.D. (Mamimum)) |
- |
|
|
|
| 7.1.1.1 (DIMENSIONS-PIPE-Mean O.D. Variation) |
- |
|
|
|
| 7.1.1.2 (DIMENSIONS-PIPE-O.D. at any Point (Minimum)) |
- |
|
|
|
| 7.1.1.2 (DIMENSIONS-PIPE-O.D. at any Point (Maximum)) |
- |
|
|
|
| 7.1.1.2 (DIMENSIONS-PIPE-Ovality (Maximum)) |
- |
|
|
|
| 7.1.2.1 (DIMENSIONS-PIPE-Thickness(Minimum)) |
- |
|
|
|
| 7.1.2.1 (DIMENSIONS-PIPE-Thickness(Maximum)) |
- |
|
|
|
| 7.1.2.1 (DIMENSIONS-PIPE-Average Thickness) |
- |
|
|
|
| Cl- 7.2 (Socket length (Take 4 reading & minimum will be reported)) |
- |
|
|
|
| 7.2.1 (DIMENSIONS-Socket) |
- |
|
|
|
| 7.2.1.1-Table 3 (DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Minimum)) |
- |
|
|
|
| 7.2.1.1-Table 3 (DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Maximum)) |
- |
|
|
|
| 7.2.1.2(a)-Table 5 (DIMENSIONS-Sockets for elastomeric sealing ring joints-Minimum depth of engagement) |
- |
|
|
|
| 10.7 (Sulphated Ash Content) |
- |
|
|
|
| 7.2.1.2-Table 4 (DIMENSIONS-Sockets for elastomeric sealing ring joints-Socket inner Diameter) |
- |
|
|
|
| 8 (SEALING RINGS) |
- |
|
|
|
| 9.1 (PIPE ENDS) |
- |
|
|
|
| 10.1 (PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
|
|
|
| 10.1.1 (PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
|
|
|
| 10.2 (PHYSICAL AND CHEMICAL CHARACTERISTICS-Opacity) |
- |
|
|
|
| 10.4 (PHYSICAL AND CHEMICAL CHARACTERISTICS- Reversion Test) |
- |
|
|
|
| 10.5 (PHYSICAL AND CHEMICAL CHARACTERISTICS- Vicat Softening Temperature) |
- |
|
|
|
| 10.6 (PHYSICAL AND CHEMICAL CHARACTERISTICS- Density) |
- |
|
|
|
| 11.1-Table 6 (MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)) |
- |
|
|
|
| 11.1-Table 6 (MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)) |
- |
|
|
|
| 11.2 (Resistance to External Blows at 0°C) |
- |
|
|
|
| 13.1 (Marking) |
- |
|
|
|
| cL-13.1.1 (Marking) |
- |
|
|
|
| Cl-13.1.2 (Marking) |
- |
|
|
|
|
- |
- Excluding Effect on water |
| 15488 |
BIS, Central Laboratory (CL)
| None
| IS 4984 (2016) |
Polyethylene pipes for water supply - Specification (Fifth Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 8.3 (Carbon Black Content) |
- |
|
|
|
| Cl-7.4 (Mean Outside Diameter (For upto 50 mm take 8 reading, above 50mm take 6 reading & average will be reported)) |
- |
|
|
|
| 8.2 (Longitudinal Reversion Test) |
- |
|
|
|
| Cl 8.3 (Carbon Black Dispersion) |
- |
|
|
|
| 8.7 (Density) |
- |
|
|
|
| 8.4 ( Melt Flow Rate) |
- |
|
|
|
| 7.4.1.2 (Ovality) |
- |
|
|
|
| 7.2 (Length) |
- |
|
|
|
| 6.2 (Colour) |
- |
|
|
|
| 6.2.1 (6.1.1 Identification Stripes) |
- |
|
|
|
|
- |
- Excluding Oxidation induction , overall migration, Cl 8.7 density, Cl 7.4.1.2 ovality Cl 8.8 Tensile,Cl 8.9 Elongation at Break; |
| 15489 |
BIS, Central Laboratory (CL)
| None
| IS 2202 : Part 1 (2023) |
WOODEN FLUSH DOOR SHUTTERS SOLID CORE TYPE SPECIFICATION PART 1 PLYWOOD FACE PANELS Seventh Revision |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 (GRADE) |
- |
|
|
|
| 4 (Grade, Type and Construction) |
- |
|
|
|
| 7.3.2 (CONSTRUCTION-Stiles and Rails) |
- |
|
|
|
| 11.1 (Dimensions - Height) |
- |
|
|
|
| 11.1 (Dimensions - Width) |
- |
|
|
|
| 11.1 (Dimensions - Thickness) |
- |
|
|
|
| 11.1 (Dimensions - Variation in thickness) |
- |
|
|
|
| 11.12 (End immersion test) |
- |
|
|
|
| 11.1 (Dimensions - Squareness) |
- |
|
|
|
| 9.1 (Workmanship & Finish) |
- |
|
|
|
| 9.2 (Workmanship & Finish) |
- |
|
|
|
| 9.3 (Workmanship & Finish) |
- |
|
|
|
| 11.2 (General Flatness Test) |
- |
|
|
|
| 11.3 (Local Planeness Test) |
- |
|
|
|
| Clause 11.4 (Impact Indentation Test) |
- |
|
|
|
| 11.5 (Flexure Test) |
- |
|
|
|
| 11.6 (Edge Loading Test) |
- |
|
|
|
| 11.7.1 (Shock Resistance Test) |
- |
|
|
|
| 11.7.2 (Shock Resistance Test) |
- |
|
|
|
| Clause 11.8 (Buckling Resistance Test) |
- |
|
|
|
| Clause 11.9 (Slamming Test) |
- |
|
|
|
| Clause 11.10 (Misuse Test) |
- |
|
|
|
| Clause 11.11 (Varying Humidity Test) |
- |
|
|
|
| 11.13 (Knife Test) |
- |
|
|
|
| Clause 11.14 (Glue Adhesion Test) |
- |
|
|
|
| Clause 11.15 (Screw Withdrawal
Resistance Test) |
- |
|
|
|
| 7.3.3 (CONSTRUCTION-Stiles and Rails) |
- |
|
|
|
|
- |
- Excluding Test facility not available for Cl 11.2, 11.4, 11.6, 11.8, 11.9; |
| 15490 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 6003 (2010) |
Indented Wire For--Prestressed Concrete ” |
- |
Rs.4110/- excl. relaxation test View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5.1 (Diameter) |
- |
|
|
|
| Cl 6.1.2 (Weight) |
- |
|
|
|
| Cl 7.1 (Tensile Test On UTM) |
- |
|
|
|
| Cl 7.2 (Tensile Test On UTM) |
- |
|
|
|
| Cl 7.3 (Reverse Bend Test) |
- |
|
|
|
| Cl 7.4 (Tensile Test On UTM) |
- |
|
|
|
| Cl 7.5 (Load ) |
- |
|
|
|
| 4.1.1 (Phosphorus %) |
- |
|
|
|
| 4.1.1 (Sulphur %) |
- |
|
|
|
|
- |
- All test facilities are available as per IS except i. Proof Stress (Clause 7.2) ii. Relaxation (Clause 7.5) |
| 15491 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 7224 (2006) |
Iodized salt, vacuum evaporated iodized salt and refined iodized salt - Specification (Second Revision) |
- |
Rs7440/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.2 (Particle Size) |
- |
|
|
|
| Clause 4.3 Table 1 (Moisture content) |
- |
|
|
|
| Clause 4.3 Table 1 (water insoluble matter) |
- |
|
|
|
| Clause 4.3 Table 1 (Chloride Content(as Nacl)) |
- |
|
|
|
| Clause 4.3 Table 1 (Matter soluble in water other than sodium chloride) |
- |
|
|
|
| Clause 4.3 Table 1 (Calcium (as Ca)) |
- |
|
|
|
| Clause 4.3 Table 1 (Magnesium (as mg)) |
- |
|
|
|
| Clause 4.3 Table 1 (Sulphate (as SO4 ),) |
- |
|
|
|
| Clause 4.3 Table 1 (Iodine content, a) Manufacturers Level ) |
- |
|
|
|
| Clause 4.3 Table 1 (Alkalinity (as Na2CO3),) |
- |
|
|
|
| Clause 4.3 Table 1 (Iron(as Fe)) |
- |
|
|
|
| Clause no4.1 (Description) |
- |
|
|
|
| Clause 4.3 Table 1 (Arsenic(as As)) |
- |
|
|
|
|
- |
- Complete except Lead. |
| 15492 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 277 (2018) |
Galvanized steel strips and sheets (Plain And Corrugated) - Specification (Seventh Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8.2 (Press) |
- |
|
|
|
| Cl 13 (Weight) |
- |
|
|
|
| Cl. 14 & Cl. 15 (Pitch of corrugation (average of 4)) |
- |
|
|
|
| Cl. 14 & Cl. 15 (Depth of corrugation (average of 4)) |
- |
|
|
|
| Cl. 14 & Cl. 15 (Cl. 14 & Cl 15 (Number of Corrugation)) |
- |
|
|
|
| Cl. 14 & Cl. 15 (Cl. 14 & Cl 15 (Difference between Diagonal)) |
- |
|
|
|
| Cl. 14 & Cl. 15 (Cl. 14 & Cl. 15 (Thickness)) |
- |
|
|
|
| Cl. 14 (Cl. 14 & Cl 15 (Width)) |
- |
|
|
|
| Cl. 14 (Cl. 14 & Cl 15 (Length)) |
- |
|
|
|
| Cl.12 (Freedom from defects) |
- |
|
|
|
| Cl. 8.1 (Cl. 8.1 (Percentage Elongation )) |
- |
|
|
|
| Cl. 8.1 (Cl. 8.1 (Yield Stress)) |
- |
|
|
|
| Cl. 8.1 (Cl. 8.1 (Tensile Strength)) |
- |
|
|
|
| 5.1 (carbon) |
- |
|
|
|
| 5.1 (manganese) |
- |
|
|
|
| 5.1 (phosphorus) |
- |
|
|
|
| 5.1 (sulphur) |
- |
|
|
|
| 7.4 (Mass of Coating: Single Spot Test) |
- |
|
|
|
| 7.4 (Mass of Coating: Triple Spot Test) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS. |
| 15493 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 11513 (2017) |
Hot rolled carbon steel strip for cold rolling purposes - Specification (Second Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8 (Workmanship) |
- |
|
|
|
| Cl 9 (Length, Width, Thickness, Crown, Edge Camber & Difference in Thickness Across Width ) |
- |
|
|
|
| 6.1 (Carbon %) |
- |
|
|
|
| 6.1 (Manganese %) |
- |
|
|
|
| 6.1 (Phosphorus %) |
- |
|
|
|
| 6.1 (Sulphur %) |
- |
|
|
|
| 6.1 (Silicon %) |
- |
|
|
|
| 6.1 ( Nitrogen%) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS except i. Size upto 1500 mm Width |
| 15494 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 9825 (2003) |
Chlorine tablets - Specification (Second Revision) |
- |
Rs.4330/ View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.4.2 (Description) |
- |
|
|
|
| Cl.4.3 (Size (Mass of tablet)) |
- |
|
|
|
| Cl.4.3 (Available Chlorine (Annex A)) |
- |
|
|
|
| Cl.4.4 (Moisture (Annex B)) |
- |
|
|
|
| Cl.4.4 (Shelf Life (Annex A)) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS |
| 15495 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 1011 (2002) |
Biscuits - Specification (Fourth Revision) |
- |
Rs.3280/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1 (General Requirement) |
- |
|
|
|
| 6.3 Table 2 i (Moisture) |
- |
|
|
|
| 6.3 Table 2 ii (Acid insoluble ash (on dry basis)) |
- |
|
|
|
| 6.3 Table 2 iii (Acidity of extracted fat (as oleic acid)) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS |
| 15496 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 1759 (1986) |
Specification for powrahs (Second Revision) |
- |
Rs.2100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.1 (Shapes) |
- |
|
|
|
| 2.1 (Dimensions of Powrah-A) |
- |
|
|
|
| 2.1 (Dimensions of Powrah-B) |
- |
|
|
|
| 2.1 (Dimensions of Powrah-C) |
- |
|
|
|
| 2.1 (Dimensions of Powrah-D) |
- |
|
|
|
| 2.1 (Dimensions of Powrah-E) |
- |
|
|
|
| 2.1 (Dimensions of Powrah-F) |
- |
|
|
|
| 2.1 (Dimensions of Powrah-G) |
- |
|
|
|
| 2 Fig 11 (Dimensions of Eye-H) |
- |
|
|
|
| 2 Fig 11 (Dimensions of Eye-J) |
- |
|
|
|
| 2 Fig 11 (Dimensions of Eye-K) |
- |
|
|
|
| 2 Fig 11 (Dimensions of Eye-L) |
- |
|
|
|
| 2 Fig 11 (Dimensions of Eye-M) |
- |
|
|
|
| 2.3 (Blade thickness) |
- |
|
|
|
| 4 (Mass) |
- |
|
|
|
| 5.2 (Hardness) |
- |
|
|
|
| 6.1 (Workmanship & Finish) |
- |
|
|
|
| 6.1 (Workmanship & Finish) |
- |
|
|
|
| 6.1 (Workmanship & Finish) |
- |
|
|
|
| 6.1 (Workmanship & Finish) |
- |
|
|
|
| 6.2 (Workmanship & Finish) |
- |
|
|
|
| 7.1 (Preservative Treatment) |
- |
|
|
|
| 7.2 (Preservative Treatment) |
- |
|
|
|
| 10.1 (Drop test) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS except- i. Hardness Test (Clause 5.2) |
| 15497 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 278 (2009) |
Galvanized steel barbed wire for fencing - Specification (Fourth Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 (Type A/Type B) |
- |
|
|
|
| 5 Table-1 (Sizes Diameter of Line wire) |
- |
|
|
|
| 5 Table-1 (Sizes Diamater of Point wire) |
- |
|
|
|
| 5 Table-1 (Sizes Mass of Completed barbed wire) |
- |
|
|
|
| 5 Table-1 (Sizes Distance between two barbs) |
- |
|
|
|
| 5 Table-1 (Sizes No. of Lays between the two consequtive barbs) |
- |
|
|
|
| 7.1 (Manufacture) |
- |
|
|
|
| 7.2 (Manufacture) |
- |
|
|
|
| 7.2 (Manufacture) |
- |
|
|
|
| 7.3 (Manufacture) |
- |
|
|
|
| 8 (CHROMATING) |
- |
|
|
|
| 9.1 (Freedom from defects) |
- |
|
|
|
| 9.2 (Freedom from defects) |
- |
|
|
|
| 9.2 (Freedom from defects) |
- |
|
|
|
| 9.2 (Freedom from defects) |
- |
|
|
|
| 12.1 (Tensile Strength) |
- |
|
|
|
| 12.1 (Breaking load) |
- |
|
|
|
| 12.2.1 (Mass of zinc coating (line wire)) |
- |
|
|
|
| 12.2.2 (Mass of zinc coating (point wire)) |
- |
|
|
|
| 12.2 (Uniformity of zinc coating) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS. |
| 15498 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 1239 : Part 1 (2004) |
Steel tubes, tubulars and other wrought steel fittings - Specification: Part 1 steel tubes (Sixth Revision) |
- |
9200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 10.1 (Manufacturing ) |
- |
|
|
|
| Cl 10.1.1 (Manufacturing ) |
- |
|
|
|
| 7, 6.1.1 (CARBON) |
- |
|
|
|
| 7, 6.1.1 (SULPHUR) |
- |
|
|
|
| 7, 6.1.1 (PHOSPHURS) |
- |
|
|
|
| 7, 6.1.1 (MANGANESE) |
- |
|
|
|
| 12 AND AS PER IS 4736 (UNIFORMITY OF ZINC COATING) |
- |
|
|
|
| 12 AND AS PER IS 4736 (MASS OF ZINC COATING) |
- |
|
|
|
| Cl. 14.1 (Tensile Strength) |
- |
|
|
|
| Clause 14.1.1 (Elongation Percent) |
- |
|
|
|
| Cl. 14.2 (Bend Test (uto and including 50 mm NB)) |
- |
|
|
|
| Cl. 14.3 (Flattening test (Over 50 mm NB)) |
- |
|
|
|
| Cl. 15 (Workmanship) |
- |
|
|
|
| Cl. 8 Table 3,4 & 5 (Outside Diameter) |
- |
|
|
|
| Cl. 8, 9 Table 3,4 & 5 (Thickness) |
- |
|
|
|
| Cl. 8, 9 Table 3,4 & 5 (Mass of Tube) |
- |
|
|
|
| Cl. 6.5 (Height of Internal Fin) |
- |
|
|
|
| Cl. 3.3, 10.2 (Plain End) |
- |
|
|
|
| Clause 8.1 (Table3,4,5) (Nominal Bore) |
- |
|
|
|
| Clause 11.1 (Random Length) |
- |
|
|
|
| Clause 11.2 (Exact Length) |
- |
|
|
|
| Clause 11.3 (Approximate Length) |
- |
|
|
|
|
- |
- "Except Leak Proof Test
(The Hydrostatic Test has to be carried out at the manufacturers' end only. )"
*- The exact sample type, size and quantity may be ascertained from the latest product manual issued by BIS. |
| 15499 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 7887 (1992) |
Mild steel wire rod for general engineering purposes - Specification (First Revision) |
- |
Rs.7200/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8 (Workmanship) |
- |
|
|
|
| Cl 9 (Nominal Diameter & Out Of Shape) |
- |
|
|
|
| 6.1 (Carbon %) |
- |
|
|
|
| 6.1 (Manganese %) |
- |
|
|
|
| 6.1 (Phosphorus %) |
- |
|
|
|
| 6.1 (Sulphur %) |
- |
|
|
|
| 6.1 (Silicon %) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS. |
| 15500 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 8249 (2019) |
Zinc sulphate heptahydrate, agricultural grade - Specification (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| (Clauses 3.2 and 6.2) Table 1 (Matter insoluble in water) |
- |
|
|
|
| (Clauses 3.2 and 6.2) Table 1 (Zinc (as Zn)) |
- |
|
|
|
| (Clauses 3.2 and 6.2) Table 1 (Lead (as Pb)) |
- |
|
|
|
| (Clauses 3.2 and 6.2) Table 1 (Copper (as Cu)) |
- |
|
|
|
| (Clauses 3.2 and 6.2) Table 1 (Magnesium (as Mg)) |
- |
|
|
|
| (Clauses 3.2 and 6.2) Table 1 (pH) |
- |
|
|
|
| (Clauses 3.2 and 6.2) Table 1 (Cadmium (as Cd)) |
- |
|
|
|
| (Clauses 3.2 and 6.2) Table 1 (Arsenic (as As)) |
- |
|
|
|
| (Clauses 3.2 and 6.2) Table 1 (Sulphur (as S)) |
- |
|
|
|
|
- |
- - |
| 15501 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 1341 (2018) |
Steel Butt Hinges - Specification (Sixth Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3 Tables 2 to 9 (Types) |
- |
|
|
|
| 5.1 Tables 2 to 9 (2) (Size of Hinge) |
- |
|
|
|
| 5.1 Tables 2 to 9 (3) (Length A) |
- |
|
|
|
| 5.1 Tables 2 to 9 (4) (Breadth B) |
- |
|
|
|
| 5.1 Tables 2 to 9 (4) (Breadth B1) |
- |
|
|
|
| 5.1 Tables 2 to 9 (4) (Breadth B2) |
- |
|
|
|
| 5.1 Tables 2 to 9 (5) (Thickness of Flap C) |
- |
|
|
|
| 5.1 Tables 2 to 9 (6) (Diameter of Hinge Pin D) |
- |
|
|
|
| 5.1 Tables 2 to 9 (7) (Number of Knuckles) |
- |
|
|
|
| 5.1 Tables 2 to 9 (8) (Number of Screw Holes) |
- |
|
|
|
| 5.1 Tables 2 to 9 (9) (Holes for Screw No.) |
- |
|
|
|
| 6.1 (General) |
- |
|
|
|
| 6.1 (General) |
- |
|
|
|
| 6.2.1 (Knuckles) |
- |
|
|
|
| 6.3 (Pins) |
- |
|
|
|
| 6.4 (Screw Holes) |
- |
|
|
|
| 6.4.2 (Position of Holes) |
- |
|
|
|
| 6.4.2 (X) |
- |
|
|
|
| 6.4.2 (Y) |
- |
|
|
|
| 6.4.2 (Z) |
- |
|
|
|
| 6.4.2.1 (Position of Holes) |
- |
|
|
|
| 7 (Finish) |
- |
|
|
|
| TABLE-1 (Clause-4) ( CARBON) |
- |
|
|
|
| TABLE-1 (Clause-4) (SULPHUR) |
- |
|
|
|
| TABLE-1 (Clause-4) (PHOSPHURS) |
- |
|
|
|
| TABLE-1 (Clause-4) (MANGANESE) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS. |
| 15502 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 1328 (2025) |
Veneered Decorative Plywood - Specification ( Fourth Revision ) |
- |
Please see remarks View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 4.1 (Grades) |
- |
|
|
|
| Cl 7.1 (Surface Requirements- For Type 1) |
- |
|
|
|
| Cl 8.1 (Dimensions (Length and Width)) |
- |
|
|
|
| Cl 8.2 (Dimensions (Thickness)) |
- |
|
|
|
| Cl 8.3 (Squareness and Edge Straightness as Per Annex B) |
- |
|
|
|
| Cl 11.3 (Moisture Content) |
- |
|
|
|
| Cl 11.4.1(a) (Water Resistance Test( For MR Grade)) |
- |
|
|
|
| Cl 11.5 (Formaldehyde Content Test) |
- |
|
|
|
|
- |
- Complete except optional test |
| 15503 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 12330 (1988) |
Specificatioon for sulphate resisting Portland cement |
- |
Rs.12900/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 - Table - 1 i (Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
| 4.1 - Table - 1 ii (Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
|
|
|
| 4.1 - Table - 1 iii (Magnesia - Cl 4.8 of IS 4032:1985) |
- |
|
|
|
| 4.1 - Table - 1 iv (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
|
|
|
| 4.1 - Table - 1 v (Tricalcium aluminate (C3A) - Cl 4 of IS 4032:1985) |
- |
|
|
|
| 4.1 - Table - 1 vi (Tetracalcium alumino ferrite phase plus twice the tricalcium aluminate ( C4AF + 2C3A ) - Cl 4 of IS 4032:1985) |
- |
|
|
|
| 4.1 - Table - 1 vii (Total loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
|
|
|
| 5.1 (Fineness 4031 Part 2) |
- |
|
|
|
| 5.2.1 (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
| 5.2.1.1 (Expansion after aeration - 4031 Part 3) |
- |
|
|
|
| 5.2.1 (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
| 5.2.1.1 (Expansion after aeration- 4031 Part 3) |
- |
|
|
|
| 5.3 a) (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
| 5.3 b) (Setting Time Final- 4031 Part 5) |
- |
|
|
|
| 5.5 i) (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
| 5.5 ii) (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
| 5.5 iii) (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
|
- |
- Except Fineness (0 ) |
| 15504 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 10228 (1982) |
Specification for school bag |
- |
Rs 2700/- + charges as per relevant ISS View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1 ( Dimensions-A) |
- |
|
|
|
| 3.1 (Dimensions-B) |
- |
|
|
|
| 3.1 (Dimensions-B1) |
- |
|
|
|
| 3.1 (Dimensions-C1) |
- |
|
|
|
| 3.1 (Dimensions-C2) |
- |
|
|
|
| 3.1 (Dimensions-C3) |
- |
|
|
|
| 3.1 (Dimensions-D) |
- |
|
|
|
| 3.1 (Dimensions-E) |
- |
|
|
|
| 3.1 (Dimensions-F) |
- |
|
|
|
| 3.1 (Dimensions-G) |
- |
|
|
|
| 3.1 (Dimensions-H) |
- |
|
|
|
| 3.1 (Dimensions-J) |
- |
|
|
|
| 3.1 (Dimensions-K) |
- |
|
|
|
| 3.1.1 (The length of back strap) |
- |
|
|
|
| 3.1.2 (The length of side strap) |
- |
|
|
|
| 5.1 (Manufacture, Workmanship & Finish) |
- |
|
|
|
| 5.2 (Manufacture, Workmanship & Finish) |
- |
|
|
|
| 5.3 (Manufacture, Workmanship & Finish) |
- |
|
|
|
| 5.4 (Manufacture, Workmanship & Finish) |
- |
|
|
|
| 5.5 (Manufacture, Workmanship & Finish) |
- |
|
|
|
| 5.6 (Manufacture, Workmanship & Finish) |
- |
|
|
|
| 7.1 ( Drop Test) |
- |
|
|
|
| 7.2 (Handle snatch test) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS |
| 15505 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 1417 (2016) |
Gold and gold alloys, jewellery/ artefacts - Fineness and marking - Specification (Fourth Revision) |
9K375, 14K585, 18K750, 20K833, 22K916, 23K958) and Gold Alloy/ Bullion (24KS995, 24KF999) |
Rs.1800.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Fineness/ Gold Content in parts per thousand, percent) |
- |
|
|
|
| 4.1.1 (b) (Cadmium, Percent) |
- |
|
|
|
| 4.1.1 (b) (Each of Platinum Group Metals, Percent) |
- |
|
|
|
| 4.1.1 © (Presence of Iridium, Ruthenium & Cadmium) |
- |
|
|
|
| 4.1 (Fineness/ Gold Content in parts per thousand, percent) |
- |
|
|
|
| 4.1 (Fineness/ Gold Content in parts per thousand, percent) |
- |
|
|
|
|
- |
- Yellow Gold Alloy Jewellery - (9K375, 14K585, 18K750, 20K833, 22K916, 23K958) and Gold Alloy/ Bullion (24KS995, 24KF999)
Min sample quantity for 9K - 1.5 gram and for other grade as per guidelines. |
| 15506 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 13428 (2005) |
Packaged natural mineral water specification (Second Revision) |
- |
19200 View breakup
All except Radio Active Residues (RAR)- Rs 19200.00, All except Pesticide Residues (PRs) & RARs- Rs. 13900.00, All except Micro, PRs & RARs- Rs. 8750.00, Only Micro- Rs. 5900.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1.1 (Escherichia coli(or thermotolerant bacteria)) |
- |
|
|
|
| 6.1.2 (Coliform , bacteria) |
- |
|
|
|
| 6.1.3 (Faecal Streptococci ) |
- |
|
|
|
| 6.1.3 (Staphylococcus Aureus) |
- |
|
|
|
| 6.1.4 (Sulphite Reducing Anaerobes ) |
- |
|
|
|
| 6.1.5 (Pseudomonas Aeruginosa ) |
- |
|
|
|
| 6.1.6 (Yeast and Mould ) |
- |
|
|
|
| 6.1.7 (Salmonella ) |
- |
|
|
|
| 6.1.7 (Shigella) |
- |
|
|
|
| 6.1.8 (Vibrio cholera ) |
- |
|
|
|
| 6.1.8 (Vibrio parahemolyticus) |
- |
|
|
|
| 6.2 Table-1 i (Colour) |
- |
|
|
|
| 6.2 Table-1 ii (Odour) |
- |
|
|
|
| 6.2 Table-1 iii (Taste) |
- |
|
|
|
| 6.2 Table-1 iv (Turbidity) |
- |
|
|
|
| 6.2 Table-1 v (Total dissolved solids) |
- |
|
|
|
| 6.2 Table-1 vi (pH) |
- |
|
|
|
| 6.2 Table-2 i (Nitrate (as NO3)) |
- |
|
|
|
| 6.2 Table-2 ii (Nitrite (as NO2)) |
- |
|
|
|
| 6.2 Table-2 iii (Sulphide (as H2S)) |
- |
|
|
|
| 6.2 Table-2 iv (Manganese (as Mn)) |
- |
|
|
|
| 6.2 Table-2 v (Copper (as Cu)) |
- |
|
|
|
| 6.2 Table-2 vi (Zinc (as Zn)) |
- |
|
|
|
| 6.2 Table-2 vii (Flouride (as F)) |
- |
|
|
|
| 6.2 Table-2 viii (Barium (as Ba)) |
- |
|
|
|
| 6.2 Table-2 x (Borates (as B)) |
- |
|
|
|
| 6.2 Table-2 xii (Chloride (as Cl)) |
- |
|
|
|
| 6.2 Table-2 xiii (Sulphate (as SO4),) |
- |
|
|
|
| 6.2 Table-2 xiv (Magnesium (as Mg)) |
- |
|
|
|
| 6.2 Table-2 xii (Chloride (as Cl)) |
- |
|
|
|
| 6.2 Table-2 xv (Calcium (as Ca)) |
- |
|
|
|
| 6.2 Table-2 xvi (Sodium (as Na)) |
- |
|
|
|
| 6.2 Table-2 xvii (Alkalinity (as HCO3)) |
- |
|
|
|
| 6.2 Table-2 xviii (Selenium (as Se)) |
- |
|
|
|
| 6.2 Table-2 xix (Mineral Oil) |
- |
|
|
|
| 6.2 Table-2 xx (Phenolic compounds (as C6H5OH)) |
- |
|
|
|
| 6.2 Table-2 xxi (Anionic surface active agents (as MBAS)) |
- |
|
|
|
|
- |
- Excluding Cyanide, Radio Active Elements |
| 15507 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 1786 (2008) |
High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) |
- |
25780 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 7.2 (Weight) |
- |
|
|
|
| Cl 9.4 (Load In Other Direction From Bend) |
- |
|
|
|
| Cl 9.3 (Load In One Direction) |
- |
|
|
|
| Cl 9.4 (Load In Other Direction From Bend) |
- |
|
|
|
| Cl 5 (Deformations and Surface Characteristics) |
- |
|
|
|
| 4.1 (Carbon %) |
- |
|
|
|
| 4.1 (Sulphur %) |
- |
|
|
|
| 4.1 (Silicon %) |
- |
|
|
|
| 4.1 (Manganese %) |
- |
|
|
|
| 4.1 (Phosphorus %) |
- |
|
|
|
| 4.1 ( Nitrogen%) |
- |
|
|
|
| 4.1 (Sulphur and phosphorous) |
- |
|
|
|
| 4.1 (CE) |
- |
|
|
|
| Cl. 8.1 Table 3 (Tensile Strength (TS)) |
- |
|
|
|
| Cl. 8.1 Table 3 (Yield Stress (YS)) |
- |
|
|
|
| Cl. 8.1 Table 3 (Elongation, percentage) |
- |
|
|
|
| Cl. 8.1 Table 3 (TS/YS ratio) |
- |
|
|
|
|
- |
- Except Pull out test, Microalloying Elements |
| 15508 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 1161 (2014) |
Steel tubes for structural purposes - Specification (Fifth Revision) |
- |
5725 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 7 (Workmanship) |
- |
|
|
|
| Cl 13 (Workmanship) |
- |
|
|
|
| 8 AND AS PER IS 4736 (UNIFORMITY OF ZINC COATING) |
- |
|
|
|
| 8 AND AS PER IS 4736 (MASS OF ZINC COATING) |
- |
|
|
|
| 5 AND AS PER IS 10748 (CARBON EQUIVALENT) |
- |
|
|
|
| 5 AND AS PER IS 10748 (CARBON) |
- |
|
|
|
| Clause - 5.1, Table-3 (SILICON) |
- |
|
|
|
| Clause - 5.1, Table-3 (NITROGEN) |
- |
|
|
|
| Clause - 5.1, Table-3 (MANGANESE) |
- |
|
|
|
| Clause - 5.1, Table-3 (PHOSPHURS) |
- |
|
|
|
| Clause - 5.1, Table-3 (SULPHUR) |
- |
|
|
|
| Clause - 5.1, Table-3 ( CARBON) |
- |
|
|
|
| 9 (Straightness) |
- |
|
|
|
| 10 (Lengths) |
- |
|
|
|
| Clause 11.2, Table -2 (Elongation) |
- |
|
|
|
| Clause 11.2, Table -2 (Yield Strength) |
- |
|
|
|
| Cl 11.3.1 (Flattening test (over 50 mm NB)) |
- |
|
|
|
| Cl 11.3.1 (Cold bend test (upto & including 50 mm NB)) |
- |
|
|
|
| Cl. 6 , 6.2 Table 1 (Thickness) |
- |
|
|
|
| Cl. 6 , 6.2 Table 1 (Weight) |
- |
|
|
|
| Cl 11 (Tensile Test, Flattening Test & Cold Bend Test) |
- |
|
|
|
| Cl 6 (Outer Diameter, Thickness & Mass) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS except- i. Size upto 219.1 mm OD |
| 15509 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 455 (2015) |
Portland slag cement - Specification |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 - Table - 1 i (Insoluble residue - Cl 6.9 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 ii (Magnesia - Cl 6.8 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 iii (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 6.11 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 v (Loss on ignition - Cl 6.2 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 vi (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
| 7 Table 1 iv c (Compretsive Strenqth 672 ± 4 hr
IS 4031(Part 6)) |
- |
|
|
|
| 7 Table 1 iv b (Compretsive Strenqth 168 ± 2 hr
IS 4031(Part 6)) |
- |
|
|
|
| 7 Table 1 iv a (Compretsive Strenqth .72 ± 1 hr
IS 4031(Part 6)) |
- |
|
|
|
| 7 Table 1 iii b (Setting Time ( by Vicat Apparatus ), Final
IS 4031(Part 5)) |
- |
|
|
|
| 7 Table 1 iii a (Setting Time ( by Vicat Apparatus ),Initial
IS 4031(Part 5)) |
- |
|
|
|
| 7 Table 1 ii b (Soundness, Autoclave expansion
IS 4031(Part 3) ) |
- |
|
|
|
| 7 Table 1 ii a (Soundness, Le-Chate1ier expansion
IS 4031(Part 3) ) |
- |
|
|
|
|
- |
- " 8 kg+300gm
Excluding Except for Transverse strength (Optional test), Requirement for testing Alkali Content may be specifically mentioned. |
| 15510 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 13592 (2013) |
Unplasticized Polyvinyl Chloride (PVC-U) Pipes for Soil and Waste Discharge System Inside and Outside Buiildings Including Ventilation and Rainwater System |
- |
9000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.5 (Surface colour of the pipes shall be dark shade of grey) |
- |
|
|
|
| Cl.7.1 (Mean out side Diameter (For less than or equal to 40 mm- Average of 8 , For higher diameters up to 110 mm average of 6)) |
- |
|
|
|
| Cl.7.1 (Outside Diameter at any point (Take 8 reading reported minimum, maximum)) |
- |
|
|
|
| Cl.7.1 (Wall thickness "minimum,maximum" (Take 8 reading)) |
- |
|
|
|
| Cl.7.2 (Pipes shall be supplied in nominal lengths of 2, 3, 4 or
6 metres either plain or with socket for solvent
cementing/grooved socket. Tolerances on specified
length shall be + 10 mm and – 0 mm.The nominal length of the pipe with socket for solvent
cementing/grooved socket shall be as given in Fig. 1.) |
- |
|
|
|
| Cl.7.3.1 (Minimum wall thickness of socket on pipes shall
be as given in Table 2 read with Fig. 2 and Fig. 3.) |
- |
|
|
|
| Cl.7.3.2 (Dimensions of sockets for solvent cementing and
grooved sockets of pipes shall be as given in Tables 3
and 4 respectively, read with Fig. 2 and 3.) |
- |
|
|
|
| Cl.8.1 (The internal and external surface of the pipes shall be
smooth and clean, and free from grooving and other
defects. The end shall be clearly cut and shall be square
with the axis of the pipe. The end may be chamfered
on the plain side.) |
- |
|
|
|
| Cl.8.2 (When tested by the method described in IS 12235
(Part 5), a length of pipe sample of 200 ± 20 mm shall
not alter in length by more than 5 percent. In the case
of socket ended pipes, this test shall be carried out on
the plain portion of pipe taken at least 100 mm away
from the root of the socket.) |
- |
|
|
|
| Cl8.3 (This test shall be carried out for socket end pipes only.
When tested by the method described in IS 12235
(Part 6), the test specimens shall not show blisters,
excessive delamination or cracking or signs of weld
line splitting.) |
- |
|
|
|
| Cl.10.2 (When determined in accordance with the method
described in IS 12235 (Part 13), the tensile strength at
break shall not be less than 45 MPa.) |
- |
|
|
|
| Cl.10.3 (The axial shrinkage shall not exceed 2 percent when
determined in accordance with Annex B.) |
- |
|
|
|
| Cl.8.4 (When determined in accordance with IS 12235 (Part 2),
the vicat softening temperature of the specimen shall
not be less than 79°C.) |
- |
|
|
|
| Cl. 9, IS 12235 Part 7 (Resistance to Sulphuric Acid) |
- |
|
|
|
| Cl.10.1 (When tested by method prescribed in IS 12235 (Part 9),the pipe shall have a true impact rate of not more than
10 percent. Mass of striker and height of fall shall be
as per Annex A.) |
- |
|
|
|
| Cl. 12, IS 12235 Part 11 (Resistance to Di-Chloro-Methane) |
- |
|
|
|
|
- |
- Complete except effect on Water.
"Except Water Tightness Of Joint