15451 BIS, Northern Regional Laboratory (NRL) None IS 13334 : Part 1 (2014) Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) - 10430/- View breakup
-
- -
Testing Facility is complete
15452 BIS, Southern Regional Laboratory (SRL) None IS 14255 (1995) Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification - - View breakup
-
- -
" 15m Excluding 1.)Complete for XLPE Insulation ; 2.)Except Carbon black test , Melt flow index , Vicat softening point , Environmental stress cracking test for PE insulation, Except C1 & C2 Category
15453 BIS, Southern Regional Laboratory (SRL) None IS 9537 : Part 3 (1983) Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials - Please check remarks View breakup
-
- -
6x3m
15454 BIS, Southern Regional Laboratory (SRL) None IS 12045 (1987) Specification for alloys used in electrical resistance metallic heating elements - - View breakup
-
- -
" mech - 2 x 500 mm Excluding except Chemical tests
15455 BIS, Northern Regional Laboratory (NRL) None IS 8783 : Part 4 : Sec 1 (1995) Winding wires for submersible motors - Specification: Part 4 specification for indmdual wires: Sec 1 HR PVC insulated wires (First Revision) - 9300/- View breakup
-
- -
Test facility is complete
15456 BIS, Eastern Regional Laboratory (ERL) None IS 12367 (1988) Specification for cold - Rolled carbon steel strips/coils for manufacture of welded tubes All grades/varieties - View breakup
-
- -
Grade to be declared. Chem- Facility not available for Al, V, Nb, Ti, B & Mo. Type of killing and grade to be declared
15457 BIS, Eastern Regional Laboratory (ERL) None IS 1239 : Part 2 (2011) Steel tubes, tubulars and other steel fittings - Specification: Part 2 steel pipe fittings (Fifth Revision) All types/sizes (pl see remarks) 3400 View breakup
-
- -
Mech- Facility not available for Cl 11.1 (Hydrostatic or pneumatic), Taper screw plug test (Cl 11.2.2). Method of manufacture, type and size designation to be declared.
15458 BIS, Southern Regional Laboratory (SRL) None IS 398 : Part 5 (1992) Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) - 11400 View breakup
-
- -
" 5 m Excluding Except surface, carona & Radio Interference Test
15459 BIS, Southern Regional Laboratory (SRL) None IS 11952 (1986) Specification for steels for piston pins (Gudgeon Pins) - - View breakup
-
- -
" mech - 2 x 500 mm Excluding except inclusions test, magnetic particle test, Grain size, hardenability, surface defects and Chemical tests
15460 BIS, Southern Regional Laboratory (SRL) None IS 1785 : Part 2 (1983) Specification for plain hard drawn steel wire for prestressed concrete: Part 2 as - Drawn wire (First Revision) - Rs 3000/- View breakup
-
- -
" 2mtl. Excluding Except proof load, ductility, stress relaxation & reverse bend test
15461 BIS, Central Laboratory (CL) None IS 1079 (2017) Hot rolled carbon steel sheet, plate and strip - Specification (Seventh Revision) - - View breakup
-
- -
Grade/Designation, Quality type of killing and declaration regarding micro alloying elements addition may please be declared. Sample size- 5 pcs of 5 cm x 5 cm having dia> 3mm and thickness >0.8 mm;
15462 BIS, Southern Regional Laboratory (SRL) None IS 1159 (1981) Specification for baking powder (First Revision) - Rs.2100/- View breakup
-
- -
" 500 g
15463 BIS, Central Laboratory (CL) None IS 3854 (1997) Switches for domestic and similar purposes - Specification (Second Revision) - - View breakup
6A Screw type terminals-Rs.4900/-, 6A Screwless type terminals-Rs.5850/- ,10A Screw type terminals-Rs.5050/-, 10A Screwless type terminals-Rs.6400/-, 16A Screw type terminals-Rs.5850/-, 16A Screwless type terminals-Rs.7900/-, 20A-Rs.5250/-, 25A-Rs.5900/-, 32A-Rs.6250/-, 40A-Rs.6550/-, 63A-Rs.6200/-
- -
-
15464 BIS, Central Laboratory (CL) None IS 1489 : Part 2 (2015) Portland - Pozzolana cement - Specification: Part 2 calcined clay based - Rs.8420/- View breakup
-
- -
Excluding Table 1,Clause 6.1 ,sl. no.(vi) , alkali content;
15465 BIS, Southern Regional Laboratory (SRL) None IS 1785 : Part 1 (1983) Specification for plain hard - Drawn steel wire for prestressed concrete: Part 1 cold drawn stress - Relieved wire (Second Revision) - Rs. 27300.00 (Complete testing charges) Rs. 9300.00 (F View breakup
-
- -
" 2mt.+2m " Excluding Except proof load, ductility, stress relaxation & reverse bend test
15466 BIS, Central Laboratory (CL) None IS 1293 (2019) Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) - - View breakup
-
- -
-
15467 BIS, Southern Regional Laboratory (SRL) None IS 398 : Part 2 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) - - View breakup
-
- -
" 5 m Excluding 1.)Complete upto 100 sq mm 2.)Except surface condition test, ultimate breaking load test on stranded conductor above 100 sqmm & stress strain test on conductor
15468 BIS, Eastern Regional Laboratory (ERL) None IS 5950 (1984) Specification for shot firing cables (For Use Other Than In Shafts) (First Revision) all sizes/varieties Rs 11030/- View breakup
-
- -
Complete
15469 BIS, Northern Regional Laboratory (NRL) None IS 1703 (2000) Water Fittings - Copper Alloy Float Valves (Horizontal Plunger Type) - - Rs. 4800/-and testing charges as per referred ISs View breakup
-
- -
Except shut off and mechanical strength test, Facility for chemical testing is not available
15470 BIS, Central Laboratory (CL) None IS 12818 (2010) Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) - Rs.6450.00 View breakup
-
- -
Excluding Test facility not avaialble for Cl 9.4 Resistance to External Blows ,9.7 Effect on Water;
15471 BIS, Central Laboratory (CL) None IS 2029 (1998) Ring wrenches (Spanners) - Specification (Fourth Revision) - Rs.3700/- View breakup
-
- -
Grade designation of material as per relevant IS may please declared.; Excluding -; torque test
15472 BIS, Southern Regional Laboratory (SRL) None IS 11947 (1987) Specification for soft magnetic iron rods, bars, flats and sections - - View breakup
-
- -
" mech - 2 x 500 mm Excluding except bend test and chemical tests
15473 BIS, Southern Regional Laboratory (SRL) None IS 12146 (1987) Specification for carbon manganese steel forgings for pressure vessels - - View breakup
-
- -
" mech - 100 gm drillings " Excluding except ultrasonic test and Chemical tests
15474 BIS, Southern Regional Laboratory (SRL) None IS 14542 (1998) Partly skimmed milk powder specification - - View breakup
-
- -
" 2 x 500 g "
15475 BIS, Southern Regional Laboratory (SRL) None IS 4505 (2015) Sodium formaldehyde sulphoxylate - Specification (First Revision) - - View breakup
-
- -
" 500 g x 2 1 pack for keeping quality test as per clause 5 "
15476 BIS, Northern Regional Laboratory (NRL) None IS 398 : Part 4 (1994) Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) - Please see remarks View breakup
-
- -
Test facility is complete
15477 BIS, Northern Regional Laboratory (NRL) None IS 1673 (1984) Spectfication for mild steel wire, cold heading quality (Second Revision) - - View breakup
-
- -
-
15478 BIS, Southern Regional Laboratory (SRL) None IS 336 (1973) Specification for ether - - View breakup
-
- -
" 500 ml x 2 Excluding except distillation range, relative density
15479 BIS, Eastern Regional Laboratory (ERL) None IS 14255 (1995) Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification complete for Cat 01(Except melt flow, vicat, bending) - View breakup
-
- -
Facility not available for breaking load of messenger conductor, Carbon Black test, Vicat Test, Environmental stress cracking for PE insulation. For XLPE water absorption test facility available upto 25 sq.mm. (Facility for nominal area of conductor, Tensile & Elongation above 2.0 mm thickness is not available). 5 mtr Aluminium wire before stranding to be provided additionally.
15480 BIS, Southern Regional Laboratory (SRL) None IS 1161 (2014) Steel tubes for structural purposes - Specification (Fifth Revision) - 5725 View breakup
-
- -
" mech - 1.5 m Chemical Facility is available Quantity: 5 Pieces of 5cm X 5cm Excluding except cold bend test