S.No. Lab Name Osl Code Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
15421 BIS, Northern Regional Laboratory (NRL) None IS 1011 (2002) Biscuits - Specification (Fourth Revision) - Rs.3280/- View breakup
-
- -
Test facility is complete
15422 BIS, Southern Regional Laboratory (SRL) None IS 1029 (1970) Specification for hot-rolled steel strip (Baling) (First Revision) - Rs.750/- View breakup
-
- -
" 0.5 sq.m Excluding except tensile, bend test and chemical tests
15423 BIS, Southern Regional Laboratory (SRL) None IS 1079 (2017) Hot rolled carbon steel sheet, plate and strip - Specification (Seventh Revision) - - View breakup
-
- -
" 2x0.5 mt " Excluding Excl cupping test, Bend test (as lower sizes of manderls is not available), Strain aging test and chemical requirements
15424 BIS, Eastern Regional Laboratory (ERL) None IS 16208 (2015) Textiles - High density polyethylene (HDPE)/polypropylene (PP) woven sacks for packaging 10 kg, 15 kg, 20 kg, 25 kg and 30 kg foodgrains - Specification all varieties. Rs.19750/- (including all parameters), Rs.10450/- (excl View breakup
-
- -
Complete.
15425 MSME TESTING CENTRE (WR), MUMBAI 7119404 IS 7231 (1994) plastic flushing cisterns for waterclosets and urinals Discharge capacity from 5liter to 10liter 10500 View breakup
Rs.10,500/- + taxes
- -
-
15426 BIS, Southern Regional Laboratory (SRL) None IS 1011 (2002) Biscuits - Specification (Fourth Revision) - Rs.3280/- View breakup
-
- -
" 3 x 100 g Excluding determination acidity of extractable fat
15427 BIS, Central Laboratory (CL) None IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) - 25780 View breakup
-
- -
Microalloying element/type of killing (element)/any other element to be declared; Excluding -; Pull out test,
15428 BIS, Eastern Regional Laboratory (ERL) None IS 1061 (2025) Disinfectant Fluids, Phenolic Type - Specification ( Sixth Revision ) Class, Grade and Type to be declared - View breakup
22,151/- for Gr 1A,2A,3A and 16,151/- for Gr 1,2,3 for Disinfectant-cum-De-odorizing fluids and 16,551/- for Gr 1A,2A,3A and 10,551/- for Gr 1,2,3 for other classes
- -
Except cl 4.2.4 Description (Disinfectant-cum-De-odourizing Fluids), cl 4.8.1 Volatile Matter, cl 4.8.2 The material shall not be less than 40 percent (v/v) steam volatile oil when determined by the steam distillation, cl 4.8.3 Odour, cl 4.8.4 Persistance of Odour, cl 4.8.5 Flash Point (Abel), cl 4.6/4.2.4 Stability on storage [Description (Disinfectant-cum-De-odourizing Fluids)], cl 4.6/4.8.1 Stability on storage [Volatile Matter], cl 4.6/4.8.2 Stability on storage [The material shall not be less than 40 percent (v/v) steam volatile oil when determined by the steam distillation], cl 4.6/4.8.3 Stability on storage [Odour], cl 4.6/4.8.4 Stability on storage [Persistance of Odour], cl 4.6/4.8.5 Stability on storage [Flash Point (Abel)].
15429 MSME TESTING CENTRE (WR), MUMBAI 7119404 IS 12592 (2002) Precast concrete manhole cover and frame - Specification (First Revision) LD-2.5, MD-10,HD-20, EHD-35 9000.00 View breakup
Complete test charges
- -
-
15430 BIS, Southern Regional Laboratory (SRL) None IS 1417 (2016) Gold and gold alloys, jewellery/ artefacts - Fineness and marking - Specification (Fourth Revision) Yellow Gold Alloy Jewellery- 9K (375), 14K (585), 18K (750), 20K (833), 22K (916), 23K (958), 995 and 999 Rs.1800.00 View breakup
-
- -
Min 1.5 g sample for 9K gold jewellery without any stone/lacquer etc; Min. 1g sample for other grades of jewellery without any stone/lacquer etc
15431 BIS, Southern Regional Laboratory (SRL) None IS 17423 (2020) Medical textiles – Coveralls for COVID 19 – Specification - Rs.3650/- View breakup
-
- -
-
15432 BIS, Eastern Regional Laboratory (ERL) None IS 10631 (1983) Specification for stainless steel for welding electrode core wire All - View breakup
-
- -
Size and designation to be declared.
15433 BIS, Eastern Regional Laboratory (ERL) None IS 16353 (2015) Portland Cement Clinker - Specification - Rs. 5700/ View breakup
-
- -
Chem-Declaration for chloride regarding end use of cement (as per Table 1), Confirmation required for testing Alkali Content. Sample quantity- For physical tests 8 kg clinker ground with gypsum as per Cl 6.1, for chemical tests 2 kg clinker is to be provided.
15434 BIS, Southern Regional Laboratory (SRL) None IS 15354 : Part 1 (2018) Single - Use medical examination gloves: Part 1 specification for gloves made from rubber latex or rubber solution (First Revision) - - View breakup
-
- -
" Mech - 10 pairs
15435 BIS, Southern Regional Laboratory (SRL) None IS 10748 (2004) Hot - Rolled steel strip for welded tubes and pipes - Specification (Second Revision) - - View breakup
-
- -
" 0.5 sq.m Chemical Facility is available Quantity: 5 Pieces of 5cm X 5cm Excluding Bend test not available(Prepared test pieces are required for Tensile Test)
15436 BIS, Southern Regional Laboratory (SRL) None IS 3074 (2013) Steel tubes for automotive purposes - Specification (Third Revision) - 4200 View breakup
-
- -
" 2 mt + 50gm Excluding except LEAK TIGHTNESS TEST,chemical tests
15437 BIS, Southern Regional Laboratory (SRL) None IS 963 (1958) Specification for chrome molybdenum steel bars and rods for aircraft purposes - - View breakup
-
- -
" mech - 2 x 500 mm " Excluding except Hardenability, Grain size, Decarburization and Chemical tests
15438 BIS, Bengaluru Branch Laboratory (BNBL) None IS 398 : Part 1 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) All Rs.1600/- for 7 strands, Rs.3750/- for 19 strands View breakup
-
- -
Complete
15439 BIS, Southern Regional Laboratory (SRL) None IS 13428 (2005) Packaged natural mineral water specification (Second Revision) - 19200 View breakup
-
- -
" 48x500ml; 24x1 ltr; 6x2ltr; 4x5 ltr; 2x20ltr Excluding ex.for radio active residues , CN,mbas,Phenolic compounds
15440 BIS, Eastern Regional Laboratory (ERL) None IS 7098 : Part 1 (1988) Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) complete cat 01(except water absorption above 25sqmm) 26250 View breakup
-
- -
Elec-For cat.-01: Up to 240 sq mm all tests can be carried out (except water absorption). However, facility not available for Loss of mass above 1.2 mm thickness, Tensile & Elongation above 2.0 mm thickness and Water absorption test above 25 sq.mm cable. All facilities available for C1 & C2- except additional tests
15441 BIS, Guwahati Branch Laboratory (GBL) None IS 277 (2018) Galvanized steel strips and sheets (Plain And Corrugated) - Specification (Seventh Revision) - - View breakup
-
- -
Qty. required Mech - 2 nos. of 0.5 m x 0.5 m Chem - 5 Pcs of 5 cm x 5 cm i. Table-1, Clause 5.1 Chemical Analysis test facility not available. ii. Bend test facility not available. iii) Retain as partial
15442 BIS, Guwahati Branch Laboratory (GBL) None IS 2098 (1997) Asbestos cement building boards - Specification (First Revision) - 3300.00 View breakup
-
- -
Qty. required 2 Sheets (Full size)
15443 BIS, Bengaluru Branch Laboratory (BNBL) None IS 1507 (1977) Specification for copper oxychloride water dispersible powder concentrates - Rs 2700/- View breakup
-
- -
Complete for chemical section.
15444 BIS, Guwahati Branch Laboratory (GBL) None IS 1626 : Part 3 (1994) Asbestos Cement Building types and Pipe Fittings, Gutters and Gutter Fittings and Roofing Fittings - Part 3 : Roofing Fittings - Rs.3300.00 View breakup
-
- -
Qty. required One Pair (One Inner & One Outer)
15445 BIS, Bengaluru Branch Laboratory (BNBL) None IS 1011 (2002) Biscuits - Specification (Fourth Revision) - 3280 View breakup
-
- -
Complete for chemical section.
15446 BIS, Guwahati Branch Laboratory (GBL) None IS 1328 (1996) Veneered Decorative Plywood -Specification - - View breakup
-
- -
Qty. required 1 Nos
15447 BIS, Eastern Regional Laboratory (ERL) None IS 3074 (2013) Steel tubes for automotive purposes - Specification (Third Revision) All grades except for the tests mentioned in remarks 4200 View breakup
-
- -
Facility not available for leak tightness test. Grade designation, type, class, condition to be declared. Chem- Complete for CDS but Partial for ERW,CEW (facility not available for micro alloying elements)
15448 BIS, Bengaluru Branch Laboratory (BNBL) None IS 12701 (1996) Rotational moulded polyethylene water storage tanks - specification (First Revision) - 6900 View breakup
-
- -
Excluding: Available up to 3000 L capacity and except for Cl No 4.1 (Material) , 4.2(anti-oxidants), 4.2.1(density of resin), 4.2.2(melt flow rate), 4.3 (Reworked material).
15449 BIS, Patna Branch Laboratory (PBL) None IS 9295 (1983) Specification for steel tubes for idlers for belt conveyors (First Revision) - Rs 5100/- View breakup
-
- -
All test facilities are available as per the IS except i. Hardness Test (Clause 10)
15450 BIS, Patna Branch Laboratory (PBL) None IS 5986 (2017) Hot rolled steel sheet, plate and strip for forming and flanging purposes - Specification (Fourth Revision) - - View breakup
-
- -
All test facilities are available as per the IS except- i) Hole Expansion Ratio Test (Clause 11) and ii. Impact Test (Clause 10) facility is out of order