1.5(Components) |
- |
0 |
|
N/A |
1.6(Power interface .) |
- |
5900 |
|
Cl.1.6
Power interface
& Cl.1.6.1 AC Power Distribution System
500
Cl.1.6.2
Input Current 5000
Cl.1.6.3
Voltage limit of hand-held Equipment
200
Cl.1.6.4
Neutral Conductor 200 |
1.7(Markings and instructions) |
- |
1100 |
|
i) Cl.1.7 to xv) Cl.1.7.14 |
2.1(Protection from electric shock and energy hazards) |
- |
2400 |
|
Cl. 2 to Cl.2.1.3 |
2.2(SELV circuits) |
- |
200 |
|
Cl.2.2, Cl.2.2.1, Cl.2.2.2, Cl.2.2.3, & Cl.2.2.4,
SELV Circuits 200 |
2.3(TNV circuits) |
- |
200 |
|
N/A |
2.4(Limited current circuits) |
- |
1000 |
|
Cl.2.4, Cl.2.4.1, Cl.2.4.2, & Cl.2.4.3, Limited Current circuits 1000 |
2.5(Limited power sources .) |
- |
1000 |
|
Cl.2.5,
Limited power sources 1000 |
2.6(Provisions for earthing and bonding) |
- |
3200 |
|
Cl.2.6 to Cl.2.6.5.8 |
2.7(Overcurrent and earth fault protection in primary circuits) |
- |
1400 |
|
Cl.2.7 to Cl.2.7.6 |
2.8(Safety interlocks) |
- |
200 |
|
N/A |
2.9(Electrical insulation) |
- |
800 |
|
Cl.2.9
Electric insulation 200
Cl.2.9.1 & Cl.2.9.2
Properties of Insulating materials, Humidity Conditioning. 200
Cl.2.9.3
Grade of insulation 200
Cl.2.9.4
Separation from Hazardous voltages 200 |
2.10(Clearances, creepage distances and distances through insulation) |
- |
5800 |
|
Cl.2.10 to Cl.2.10.10 |
3.1(General) |
- |
1400 |
|
Cl.3,Cl.3.1,Cl.3.1.1,&Cl.3.1.1 to Cl.3.1.10 |
3.2(Connection to a mains supply) |
- |
1600 |
|
Cl. 3.2, Cl.3.2.1,& Cl.3.2..1.1,Cl.3.2.1.2 to Cl.3.2.9 |
3.3(Wiring terminals for connection of external conductors) |
- |
600 |
|
Cl.3.3 to Cl.3.3.8 |
3.4(Disconnection from the mains supply) |
- |
200 |
|
Cl.3.4
, Disconnection from the mains supply 200 |
3.5(Interconnection of equipment) |
- |
200 |
|
Cl.3.5
Interconnection of Equipments 200 |
4.1(Stability) |
- |
200 |
|
Cl.4
Physical Requirements, Cl.4.1
Stability 200 |
4.2(Mechanical strength) |
- |
1000 |
|
Cl.4.2 to Cl.4.2.10 |
4.3(Design and construction) |
- |
1400 |
|
Cl.4.3 to Cl.4.3.13.5 |
4.4(Protection against hazardous moving parts) |
- |
200 |
|
Cl.4.4
Protection against Hazardous Moving Parts 200 |
4.5(Thermal requirements) |
- |
400 |
|
Cl.4.5
Cl.4.5.1
Cl.4.5.2
Cl.4.5.3
Cl.4.5. Thermal Requirements
General
Temperature Test
Temperature limits for Materials
4 Touch Temperature Limits 200
Cl.4.5.5
Resistance to abnormal Heat 200 |
4.6(Openings in enclosures) |
- |
600 |
|
Cl.4.6,Cl.4.6.1, & Cl.4.6.3 Openings in enclosures 200
Cl.4.6.4
Openings in transportable equipment 200
Cl.4.6.5
Adhesives for constructional purposes 200 |
4.7(Resistance to fire) |
- |
1800 |
|
Cl.4.7 to Cl.4.7.3.6 |
5.1(Touch current and protective conductor curren) |
- |
200 |
|
Cl.5, & Cl.5.1
Electrical Requirements and simulated abnormal conditions
& Touch current and protective conductor current
& Annex D 200 |
5.2(Electric strength) |
- |
1000 |
|
Cl.5.2
Electric Strength Test 1000 |
5.3(Abnormal operating and fault conditions) |
- |
1200 |
|
Cl.5.3, Cl.5.3.1 to Cl.5.3.9.2 |
6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
2500 |
|
Cl.6.0 to Cl.6.1.2.2 |
6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
600 |
|
Cl.6.2 to Cl.6.2.2.2 & Cl.6.2.2.3 |
6.3(Protection of the telecommunication wiring system from overheating) |
- |
200 |
|
Cl.6.3
Protection of the telecommunication wiring system from overheating 200 |
7.1(General) |
- |
200 |
|
Cl.7,& Cl.7.1
Connection to cable distribution system,& General 200 |
7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
200 |
|
Cl.7.2
Protection of cable distribution system service persons, and user of other equipment connected to the system ,from hazardous voltage in the equipment 200 |
7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
200 |
|
Cl.7.3
Protection of equipment users from over voltages on the cable distribution system
200 |
7.4(Insulation between primary circuits and cable distribution systems) |
- |
400 |
|
Cl.7.4 & Cl.7.4.1
Insulation between primary circuits and cable distribution system and General 200
Cl.7.4.2
Voltage Surge Test 200
Cl.7.4.3
Impulse Test 200 |
4.2.8(Cathode Ray Tubes) |
- |
100 |
|
Ok |
4.3.10(Dust, powders, liquids and gases) |
- |
100 |
|
Ok |
4.3.11(Containers for liquids or gases) |
- |
100 |
|
Ok |
4.3.12(Flammable liquids) |
- |
100 |
|
Ok |
4.6.2(Bottoms of fire enclosures) |
- |
100 |
|
Ok |