| 91 |
IS 7872 (2020) |
Deep Freezers - Specification ( Second Revision ) |
Deep Freezers- Specification |
149500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.2.12(Temperature rise test) |
- |
10000 |
|
- |
| 10.2.11(Measurement ) |
- |
1000 |
|
- |
| 10.2.10.1(Test packages and life time) |
- |
1000 |
|
- |
| 10.2.10(Full load test) |
- |
1000 |
|
- |
| 10.2.8(Earth resistance test ) |
- |
5000 |
|
- |
| 10.2.7(Leakage current test ) |
- |
5000 |
|
- |
| 10.2.6(Insulation resistance test) |
- |
5000 |
|
- |
| 10.2.5(High voltage test) |
- |
5000 |
|
- |
| 10.2.3(Thermal insulation test ) |
- |
5000 |
|
- |
| 10.2.2(Machanical strength of shelves and similar components) |
- |
5000 |
|
- |
| 10.2.1(Door seal test ) |
- |
5000 |
|
- |
| 9.2.2(Power consumption & percentage running time) |
- |
5000 |
|
- |
| 9.2.1(Pull down time) |
- |
5000 |
|
- |
| 9.1(No load test) |
- |
5000 |
|
- |
| 6.11(Volume measurement Water fill method) |
- |
5000 |
|
- |
| 6(Measurement of freezer storage
capacity) |
- |
5000 |
|
- |
| 5.1(Sound level) |
- |
5000 |
|
- |
| 5.6(External surface condensation test) |
- |
5000 |
|
- |
| 5.5(Strength Pressure test for components) |
- |
5000 |
|
- |
| 4.8(Doors & Fittings) |
- |
5000 |
|
- |
| 13(Marking and Instruction) |
- |
1000 |
|
- |
| 11.7(Pressure Test) |
- |
10000 |
|
- |
| 11.6(Thermal Insulation Test ( External Condensation)) |
- |
10000 |
|
- |
| 11.5(Mechanical Strength of Shelves and Similar Components) |
- |
5000 |
|
- |
| 11.4(Door Seal Test) |
- |
5000 |
|
- |
| 11.3(Temperature Rise Test) |
- |
10000 |
|
- |
| 11.2(Energy Consumption Test) |
- |
10000 |
|
- |
| 11.1(No load Pull down Test) |
- |
10000 |
|
- |
| 8(Freezer Storage Capacity) |
- |
5000 |
|
- |
| 7(Sound Pressure Level) |
- |
2500 |
|
- |
| 6(Safety Requirements) |
- |
50000 |
|
- |
| 5.4.4(Fatigue Test) |
- |
10000 |
|
- |
| 5.4.3(Individual Strength - Pressure Test) |
- |
10000 |
|
- |
| 5.4.2(Individual Strength - Pressure Test) |
- |
10000 |
|
- |
| 4.8(Door and Fittings) |
- |
5000 |
|
- |
| 13(Marking and Instruction) |
- |
1000 |
|
- |
| 11.7(Pressure Test) |
- |
10000 |
|
- |
| 11.6(Thermal Insulation Test ( External Condensation)) |
- |
10000 |
|
- |
| 11.5(Mechanical Strength of Shelves and Similar Components) |
- |
5000 |
|
- |
| 11.4(Door Seal Test) |
- |
5000 |
|
- |
| 11.3(Temperature Rise Test) |
- |
10000 |
|
- |
| 11.2(Energy Consumption Test) |
- |
10000 |
|
- |
| 11.1(No load Pull down Test) |
- |
10000 |
|
- |
| 8(Freezer Storage Capacity) |
- |
5000 |
|
- |
| 7(Sound Pressure Level) |
- |
2500 |
|
- |
| 6(Safety Requirements) |
- |
50000 |
|
- |
| 5.4.4(Fatigue Test) |
- |
10000 |
|
- |
| 5.4.3(Individual Strength - Pressure Test) |
- |
10000 |
|
- |
| 5.4.2(Individual Strength - Pressure Test) |
- |
10000 |
|
- |
| 4.8(Door and Fittings) |
- |
5000 |
|
- |
| 5(Refrigeration system) |
- |
46500 |
|
- |
| Cl-4.1(General Design) |
- |
1000 |
|
- |
| Cl-4.2(Materials) |
- |
1000 |
|
- |
| Cl-4.3(Finish) |
- |
5000 |
|
- |
| Cl-4.4(Thermal Insulation) |
- |
1000 |
|
- |
| Cl-4.5(Fittings) |
- |
5000 |
|
- |
| Cl-4.6(Hardware) |
- |
1000 |
|
- |
| Cl-4.7(Interior Fittings) |
- |
5000 |
|
- |
| Cl-4.8(Doors and Fittings) |
- |
5000 |
|
- |
| Cl-4.9(Disposal of Defrost / Condensate Water) |
- |
1000 |
|
- |
| Cl-5.1(Construction) |
- |
500 |
|
- |
| Cl-5.2(Control of Operation) |
- |
500 |
|
- |
| Cl-5.3(Location of Components) |
- |
500 |
|
- |
| 6.5(For flammable refrigerant the units should comply with
IS/IEC 60335-2-89) |
- |
50000 |
|
- |
| 6.2(The compressor shall comply with the requirements
of IS 10617) |
- |
1000 |
|
- |
| 10.2.12(Temperature rise test) |
- |
0 |
|
- |
| 10.2.11(Measurement ) |
- |
0 |
|
- |
| 10.2.10.1(Test packages and life time) |
- |
0 |
|
- |
| 10.2.10(Full load test) |
- |
0 |
|
- |
| 10.2.8(Earth resistance test ) |
- |
0 |
|
- |
| 10.2.7(Leakage current test ) |
- |
0 |
|
- |
| 10.2.6(Insulation resistance test) |
- |
0 |
|
- |
| 10.2.5(High voltage test) |
- |
0 |
|
- |
| 10.2.3(Thermal insulation test ) |
- |
0 |
|
- |
| 10.2.2(Machanical strength of shelves and similar components) |
- |
0 |
|
- |
| 10.2.1(Door seal test ) |
- |
0 |
|
- |
| 9.2.2(Power consumption & percentage running time) |
- |
0 |
|
- |
| 9.2.1(Pull down time) |
- |
0 |
|
- |
| 9.1(No load test) |
- |
0 |
|
- |
| 6.11(Volume measurement Water fill method) |
- |
0 |
|
- |
| 6(Measurement of freezer storage
capacity) |
- |
0 |
|
- |
| 5.1(Sound level) |
- |
0 |
|
- |
| 5.6(External surface condensation test) |
- |
0 |
|
- |
| 5.5(Strength Pressure test for components) |
- |
0 |
|
- |
| 4.8(Doors & Fittings) |
- |
0 |
|
- |
| 13(Marking and Instruction) |
- |
0 |
|
- |
| 11.7(Pressure Test) |
- |
0 |
|
- |
| 11.6(Thermal Insulation Test ( External Condensation)) |
- |
0 |
|
- |
| 11.5(Mechanical Strength of Shelves and Similar Components) |
- |
0 |
|
- |
| 11.4(Door Seal Test) |
- |
0 |
|
- |
| 11.3(Temperature Rise Test) |
- |
0 |
|
- |
| 11.2(Energy Consumption Test) |
- |
0 |
|
- |
| 11.1(No load Pull down Test) |
- |
0 |
|
- |
| 8(Freezer Storage Capacity) |
- |
0 |
|
- |
| 7(Sound Pressure Level) |
- |
0 |
|
- |
| 6(Safety Requirements) |
- |
0 |
|
- |
| 5.4.4(Fatigue Test) |
- |
0 |
|
- |
| 5.4.3(Individual Strength - Pressure Test) |
- |
0 |
|
- |
| 5.4.2(Individual Strength - Pressure Test) |
- |
0 |
|
- |
| 4.8(Door and Fittings) |
- |
0 |
|
- |
| 13(Marking and Instruction) |
- |
0 |
|
- |
| 11.7(Pressure Test) |
- |
0 |
|
- |
| 11.6(Thermal Insulation Test ( External Condensation)) |
- |
0 |
|
- |
| 11.5(Mechanical Strength of Shelves and Similar Components) |
- |
0 |
|
- |
| 11.4(Door Seal Test) |
- |
0 |
|
- |
| 11.3(Temperature Rise Test) |
- |
0 |
|
- |
| 11.2(Energy Consumption Test) |
- |
0 |
|
- |
| 11.1(No load Pull down Test) |
- |
0 |
|
- |
| 8(Freezer Storage Capacity) |
- |
0 |
|
- |
| 7(Sound Pressure Level) |
- |
0 |
|
- |
| 6(Safety Requirements) |
- |
0 |
|
- |
| 5.4.4(Fatigue Test) |
- |
0 |
|
- |
| 5.4.3(Individual Strength - Pressure Test) |
- |
0 |
|
- |
| 5.4.2(Individual Strength - Pressure Test) |
- |
0 |
|
- |
| 4.8(Door and Fittings) |
- |
0 |
|
- |
| 5(Refrigeration system) |
- |
0 |
|
- |
| Cl-4.1(General Design) |
- |
0 |
|
- |
| Cl-4.2(Materials) |
- |
0 |
|
- |
| Cl-4.3(Finish) |
- |
0 |
|
- |
| Cl-4.4(Thermal Insulation) |
- |
0 |
|
- |
| Cl-4.5(Fittings) |
- |
0 |
|
- |
| Cl-4.6(Hardware) |
- |
0 |
|
- |
| Cl-4.7(Interior Fittings) |
- |
0 |
|
- |
| Cl-4.8(Doors and Fittings) |
- |
0 |
|
- |
| Cl-4.9(Disposal of Defrost / Condensate Water) |
- |
0 |
|
- |
| Cl-5.1(Construction) |
- |
0 |
|
- |
| Cl-5.2(Control of Operation) |
- |
0 |
|
- |
| Cl-5.3(Location of Components) |
- |
0 |
|
- |
| 6.5(For flammable refrigerant the units should comply with
IS/IEC 60335-2-89) |
- |
0 |
|
- |
| 6.2(The compressor shall comply with the requirements
of IS 10617) |
- |
0 |
|
- |
|
- |
- Included w.e.f 24.06.2025 |
| 92 |
IS 1474 (1959) |
Specification for commercial refrigerators |
Specification for Commercial Refrigerators |
284000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.5.8(Door Seal Test) |
- |
10000 |
|
- |
| 7.5.7(Test for Adequate Rating of Compressor Motor) |
- |
20000 |
|
- |
| 7.5.6(Rating Test) |
- |
20000 |
|
- |
| 7.5.5(Condensation Test) |
- |
15000 |
|
- |
| 7.5.4(Thermal Insulation Test) |
- |
10000 |
|
- |
| 7.5.3(Insulation Resistance Test (Assembly Test)) |
- |
10000 |
|
- |
| 7.5.1(Pressure Test) |
- |
15000 |
|
- |
| 3.7(Net volume) |
- |
5000 |
|
- |
| 3.6(Computation of shelf area) |
- |
5000 |
|
- |
| 3.5(Volume of fixed shelves and partitions) |
- |
5000 |
|
- |
| 3.3(Volume of evaporator space) |
- |
5000 |
|
- |
| 3.3.1(Gross Volume) |
- |
5000 |
|
- |
| Cl. 3.4(1474) |
- |
5000 |
|
- |
| Cl. 4.1(1474) |
- |
4000 |
|
- |
| Cl. 4.2(1474) |
- |
4000 |
|
- |
| Cl. 4.3(1474) |
- |
4000 |
|
- |
| Cl. 4.4(1474) |
- |
4000 |
|
- |
| Cl. 4.5(1474) |
- |
3000 |
|
- |
| Cl. 4.6(1474) |
- |
3000 |
|
- |
| Cl. 4.7(1474) |
- |
5000 |
|
- |
| Cl. 4.8(1474) |
- |
6000 |
|
- |
| Cl. 4.9(1474) |
- |
6000 |
|
- |
| Cl. 4.10(1474) |
- |
3000 |
|
- |
| Cl. 4.11(1474
Shelves) |
- |
3000 |
|
- |
| Cl. 4.12(1474) |
- |
3000 |
|
- |
| Cl. 4.13(1474) |
- |
6000 |
|
- |
| Cl. 5.1(1474) |
- |
8000 |
|
- |
| Cl. 5.2(1474) |
- |
6000 |
|
- |
| Cl. 5.3(1474) |
- |
10000 |
|
- |
| Cl. 5.4(1474) |
- |
5000 |
|
- |
| Cl. 5.5(1474) |
- |
5000 |
|
- |
| Cl. 6.1(1474) |
- |
4000 |
|
- |
| Cl. 6.2(1474) |
- |
4000 |
|
- |
| Cl. 6.3(1474) |
- |
4000 |
|
- |
| Cl. 6.4(1474) |
- |
4000 |
|
- |
| Cl. 6.5(1474) |
- |
5000 |
|
- |
| Cl. -6.6(1474) |
- |
5000 |
|
- |
| Cl. -7.5.2(1474) |
- |
10000 |
|
- |
| Cl. 9, 9.1-9.3 of IS:1474:1959(1474) |
- |
5000 |
|
- |
| Cl-3.1(Inside Dimensions) |
- |
5000 |
|
- |
| Cl-3.2(Dinzengions of the Evaporator Space) |
- |
5000 |
|
- |
| 3.1(Inside Dimensions
3.1.1(Inside Depth),
3.1.2(Inside Width),
3.1.3(Inside Height),
3.1.4(Internal Doors)) |
- |
5000 |
|
- |
| 3.2(Dimensions of the Evaporator Space) |
- |
5000 |
|
- |
|
- |
- Included w.e.f 19.06.2025 |
| 93 |
IS 11328 (2022) |
Self-contained Automatic Ice Makers Specification (First Revision) |
Self-Contained Automatic Ice Makers |
23900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.1(Construction) |
- |
2000 |
|
- |
| Cl-5.2(Water Condensation) |
- |
2000 |
|
- |
| Cl-5.3(Safety Features in Design) |
- |
2000 |
|
- |
| Cl-5.4(Control of Operation) |
- |
2000 |
|
- |
| Cl-5.5(Location of the Components) |
- |
2000 |
|
- |
| Cl-6.1(Motors) |
- |
2000 |
|
- |
| Cl-6.3(Motor Starters, Relays, Thermostat, Controls, etc) |
- |
2000 |
|
- |
| Cl-6.4(Wiring) |
- |
2000 |
|
- |
| Cl-6.5(Electrical Accessories) |
- |
2000 |
|
- |
| Cl-6.6(Earth Connection) |
- |
2000 |
|
- |
| Cl-7.1(General Requirements for Tests) |
- |
2000 |
|
- |
| Cl-7.2(Ice Weighing Instruments) |
- |
2000 |
|
- |
| Cl-7.3(Type Tests) |
- |
5000 |
|
- |
| Cl-7.4(Routine Tests) |
- |
3000 |
|
- |
| Cl-7.5(Acceptance Tests) |
- |
5000 |
|
- |
| Cl-7.6(Test Procedure) |
- |
5000 |
|
- |
| Cl-8(Marking) |
- |
500 |
|
- |
|
- |
- Included w.e.f 19.06.2025 |
| 94 |
IS 9995 (1981) |
Specification for visor for non-metal police and firemen's helmets |
Specification for Visor for Non-Metal Police and Firemen’s Helmets |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Visor Screen) |
- |
9600 |
|
Except Appendix A-1.4 Compressive Strength, Appendix A-1.5 Impact Strength, Appendix A-1.8 Rockwell Hardness test facility not available. |
| 4(Construction) |
- |
500 |
|
- |
| 5(Workmanship and Finish) |
- |
500 |
|
- |
| 6(Mass) |
- |
500 |
|
- |
| 8(Marking) |
- |
500 |
|
- |
|
- |
- Included w.e.f 17.06.2025
Exclusion: Appendix A-1.4 Compressive Strength, Appendix A-1.5 Impact Strength, Appendix A-1.8 Rockwell Hardness |
| 95 |
IS 2745 (1983) |
Specification for non - Metal helmet for firemen and civil defence personnel (Second Revision) |
- |
16700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 3(Shell, Protective padding, Retention System & Neck protector) |
- |
4000 |
|
- |
| Cl 4.1(Size Of Helmet) |
- |
900 |
|
- |
| Cl 5( Shell, Protective Padding, Brim, Head band, Chin Strap, Cradle, Neck Protector & Visor) |
- |
14000 |
|
Appendix A-1.4 of IS 9995:1981 Compressive Strength, Appendix A-1.5 of IS 9995:1981 Impact Strength, Appendix A-1.8 of IS 9995:1981 Rockwell Hardness
test facility not available. |
| Cl 6(Workmanship & Finish) |
- |
600 |
|
- |
| Cl 7(Mass) |
- |
500 |
|
- |
| Cl 9(Shock absorption test, Penitration resistance, Strength of Retention system, Electrical resistance, Water Absorption & Flammability resistance) |
- |
8000 |
|
- |
| Cl 9(Shock absorption test, Penitration resistance, Strength of Retention system, Electrical resistance, Water Absorption & Flammability resistance) |
- |
8000 |
|
- |
| Cl 7(Mass) |
- |
500 |
|
- |
| Cl 6(Workmanship & Finish) |
- |
600 |
|
- |
| Cl 5( Shell, Protective Padding, Brim, Head band, Chin Strap, Cradle, Neck Protector & Visor) |
- |
14000 |
|
- |
| Cl 4.1(Size Of Helmet) |
- |
900 |
|
- |
| Cl 3(Shell, Protective padding, Retention System & Neck protector) |
- |
4000 |
|
- |
|
- |
- Included w.e.f.27.06.2025
Exclusion
Excluding 5.3.5 visior. |
| 96 |
IS 9562 (1980) |
Specification for non - Metal helmet for police force |
Specification for non metal helmet for police force |
16000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 3(Shell, Protective padding & Retention System) |
- |
3000 |
|
- |
| Cl 4.1(Size Of Helmet) |
- |
1000 |
|
- |
| Cl 5( Shell, Protective Padding, Brim, Head band, Chin Strap, Cradle, Neck Protector & Visor) |
- |
14000 |
|
Excluding Appendix A-1.8 of IS 9995:1981 Rockwell Hardness, Appendix A-1.5 of IS 9995:1981 Impact Strength, Appendix A-1.4 of IS 9995:1981 Compressive Strength this test facility not available |
| Cl 6(Workmanship & Finish) |
- |
600 |
|
- |
| Cl 7(Mass) |
- |
500 |
|
- |
| Cl 9(Shock absorption test, Penitration resistance, Strength of Retention system, Rigidity test, Water Absorption, Flammability resistance & Firing Test) |
- |
8000 |
|
Excluding Cl. 9.7 Firing Test facility not available. |
| Cl 9(Shock absorption test, Penitration resistance, Strength of Retention system, Rigidity test, Water Absorption, Flammability resistance & Firing Test) |
- |
8000 |
|
Excluding Cl. 9.7 Firing Test facility not available. |
| Cl 7(Mass) |
- |
500 |
|
- |
| Cl 6(Workmanship & Finish) |
- |
600 |
|
- |
| Cl 5( Shell, Protective Padding, Brim, Head band, Chin Strap, Cradle, Neck Protector & Visor) |
- |
14000 |
|
Excluding Appendix A-1.8 of IS 9995:1981 Rockwell Hardness, Appendix A-1.5 of IS 9995:1981 Impact Strength, Appendix A-1.4 of IS 9995:1981 Compressive Strength this test facility not available |
| Cl 4.1(Size Of Helmet) |
- |
900 |
|
- |
| Cl 3(Shell, Protective padding & Retention System) |
- |
3000 |
|
- |
| Cl 3(Shell, Protective padding & Retention System) |
- |
0 |
|
- |
| Cl 4.1(Size Of Helmet) |
- |
0 |
|
- |
| Cl 5( Shell, Protective Padding, Brim, Head band, Chin Strap, Cradle, Neck Protector & Visor) |
- |
0 |
|
- |
| Cl 6(Workmanship & Finish) |
- |
0 |
|
- |
| Cl 7(Mass) |
- |
0 |
|
- |
| Cl 9(Shock absorption test, Penitration resistance, Strength of Retention system, Rigidity test, Water Absorption, Flammability resistance & Firing Test) |
- |
0 |
|
- |
| Cl 9(Shock absorption test, Penitration resistance, Strength of Retention system, Rigidity test, Water Absorption, Flammability resistance & Firing Test) |
- |
0 |
|
- |
| Cl 7(Mass) |
- |
0 |
|
- |
| Cl 6(Workmanship & Finish) |
- |
0 |
|
- |
| Cl 5( Shell, Protective Padding, Brim, Head band, Chin Strap, Cradle, Neck Protector & Visor) |
- |
0 |
|
- |
| Cl 4.1(Size Of Helmet) |
- |
0 |
|
- |
| Cl 3(Shell, Protective padding & Retention System) |
- |
0 |
|
- |
|
- |
- Included w.e.f 17.06.2025
Exclusion: Cl. 9.7 Firing Test, Appendix A-1.4 Compressive Strength, Appendix A-1.5 Impact Strength, Appendix A-1.8 Rockwell Hardness |
| 97 |
IS 17681 (2022) |
Specification for Bottled water dispensers |
- |
210000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Construction) |
- |
6300 |
|
- |
| 4.1(General Design) |
- |
700 |
|
- |
| 4.2(Materials) |
- |
700 |
|
- |
| 4.3(Finish) |
- |
700 |
|
- |
| 4.4(Thermal Insulation) |
- |
700 |
|
- |
| 4.5(Hardware) |
- |
700 |
|
- |
| 4.6(Disposal of Waste Water) |
- |
700 |
|
- |
| 4.7(Hot Water Tank) |
- |
700 |
|
- |
| 4.8(Hermetically Sealed Compressor) |
- |
700 |
|
- |
| 4.9(Protective Guards) |
- |
700 |
|
- |
| 5(Refrigeration System) |
- |
1000 |
|
- |
| 5.1(Pipes and Connections/Fitting) |
- |
500 |
|
- |
| 5.2(Control of Operation) |
- |
500 |
|
- |
| 6.1(General) |
- |
30700 |
|
- |
| 6.1(Protection against electric shock (Cl. 8 of IS 302-2-24)) |
- |
2000 |
|
- |
| 6.1(Power Input & Current (Cl. 10 of IS 302-2-24)) |
- |
3000 |
|
- |
| 6.1(Temperature Rise/ Heating (Cl. 11 of IS 302-2-24)) |
- |
5000 |
|
- |
| 6.1("Insulation Resistance and Electric Strength/ Leakage Current and Electric Strength
(Cl. 13 of IS 302-2-24)") |
- |
6000 |
|
- |
| 6.1("Moisture Resistance
(Cl. 15 of IS 302-2-24)") |
- |
3500 |
|
- |
| 6.1("Insulation resistance and electric strength
(After humidity treatment)
(Cl. 16 of IS 302-2-24)") |
- |
4000 |
|
- |
| 6.1("Provision For Earthing
(Cl. 27 of IS 302-2-24)") |
- |
4000 |
|
- |
| 6.2(Electrical Accessories) |
- |
1500 |
|
- |
| 6.3(Salt Mist Test) |
- |
20000 |
|
- |
| 7(Sound pressure level) |
- |
14300 |
|
- |
| 10.1(Cooling Capacity Test) |
- |
22000 |
|
- |
| 10.2(Maximum Operating Condition Test (Environmental)) |
- |
15000 |
|
- |
| 10.3(Maximum Operating Condition Test (Voltage)) |
- |
15000 |
|
- |
| 10.4(Heating Capacity Test) |
- |
15000 |
|
- |
| 10.5(Annual Energy Consumption Test) |
- |
30000 |
|
- |
| 10.6(Freeze-up Test) |
- |
20000 |
|
- |
| 10.7(Door Opening and Closing Test) |
- |
8000 |
|
- |
| 10.8(Door Seal Test) |
- |
2000 |
|
- |
| 10.9(Pull-down Test) |
- |
8000 |
|
- |
| 11(Marking and instruction) |
- |
1000 |
|
- |
| 6.1("Screws & Connections
(Cl. 28 of IS 302-2-24)") |
- |
3000 |
|
- |
|
- |
- Included w.e.f 21.05.2025 |
| 98 |
IS 17550 : PART 1 (2021) |
HOUSEHOLD REFRIGERATING APPLIANCES CHARACTERISTICS AND TEST METHODS Part 1 General Requirements |
- |
200000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| "Cl. No. 9 "(Testing The Air Tightness Of Door Or Lid Seal(S)) |
- |
6600 |
|
- |
| "Cl. No.10 "(Testing The Opening Force Of Door(S) Or Lid(S)) |
- |
9500 |
|
- |
| "Cl. No.11 "(Testing The Durability Of Hinges And Handles Of Door(S) And Lid(S)) |
- |
38000 |
|
- |
| "Cl. No.12 "(Testing The Mechanical Strength Of Shelves And Similar Components) |
- |
12000 |
|
- |
| "Cl. No.14 "(Ice-Making Test (If Applicable)) |
- |
19000 |
|
- |
| "Cl. No.15 "(Test For Absence Of Odour And Taste) |
- |
42000 |
|
- |
| "Cl. No.16 "(Safety Requirements) |
- |
42400 |
|
- |
| "Cl. No. 9 "(Testing The Air Tightness Of Door Or Lid Seal(S)) |
- |
0 |
|
Repeat Test |
| "Cl. No.10 "(Testing The Opening Force Of Door(S) Or Lid(S)) |
- |
0 |
|
Repeat Test |
| "Cl. No.11 "(Testing The Durability Of Hinges And Handles Of Door(S) And Lid(S)) |
- |
0 |
|
Repeat Test |
| "Cl. No.12 "(Testing The Mechanical Strength Of Shelves And Similar Components) |
- |
0 |
|
Repeat Test |
| "Cl. No.14 "(Ice-Making Test (If Applicable)) |
- |
0 |
|
Repeat Test |
| "Cl. No.15 "(Test For Absence Of Odour And Taste) |
- |
0 |
|
Repeat Test |
| "Cl. No.16(a) "(Protection against acess to live parts) |
- |
5000 |
|
- |
| "Cl. No.16(b) "(Power input and current) |
- |
9000 |
|
- |
| "Cl. No.16(c) "(Heating) |
- |
7000 |
|
- |
| "Cl. No.16(d) "(Leakage current and electric strength at operating temperature) |
- |
5700 |
|
- |
| "Cl. No.16(e) "(Moisture resistance) |
- |
10000 |
|
- |
| "Cl. No.16(f) "(Leakage current and electric strength) |
- |
5700 |
|
- |
| "Cl. No.20.3(a) "("Production Routine Test
a)Leakage current test
") |
- |
2800 |
|
- |
| "Cl. No.20.3(b) "(b) Earth continuity tesT) |
- |
2800 |
|
- |
| "Cl. No.20.3(c) "(c) Electric strength) |
- |
2800 |
|
- |
| "Cl. No.8.11 "(Thermostat function test) |
- |
500 |
|
- |
| "Cl. No.5 "(Markings) |
- |
2400 |
|
- |
| 4(Classification) |
- |
500 |
|
- |
| 5(Marking) |
- |
0 |
|
Repeat Test |
| 6.2(Determination of Linear Dimensions) |
- |
1000 |
|
- |
| 7(Instructions) |
- |
500 |
|
- |
| 8.2(Material and Finishes) |
- |
500 |
|
- |
| 8.3(Thermal Insulation and Air Tightness) |
- |
500 |
|
- |
| 8.4(Doors, Lids and Fittings) |
- |
500 |
|
- |
| 8.5(Shelves and Containers) |
- |
500 |
|
- |
| 8.6(Disposal of Defrost Water) |
- |
500 |
|
- |
| 8.7(Refrigerating System) |
- |
500 |
|
- |
| 8.8(Supply Cord) |
- |
500 |
|
- |
| 8.9(Compressor) |
- |
500 |
|
- |
| 8.10(Temperature Sensing Controls (Thermostat)) |
- |
500 |
|
- |
| 8.11(Temperature Sensing Controls (Thermostat) Setting) |
- |
0 |
|
Repeat Test |
| 9(Testing the Air tightness of door or lid seal(s) before water vapour condensation test) |
- |
0 |
|
Repeat Test |
| 9(Testing the Air tightness of door or lid seal(s) after water vapour condensation test) |
- |
0 |
|
Repeat Test |
| 10(Testing the Opening force of door(s) or lid(s)) |
- |
0 |
|
Repeat Test |
| 11(Testing the Durability of hinges and handles of door(s) and lid(s)) |
- |
0 |
|
Repeat Test |
| 12(Testing the Mechanical strength of shelves and similar components) |
- |
0 |
|
Repeat Test |
| 13(Water-vapour condensation test) |
- |
6000 |
|
- |
| 14(Ice-making test (if applicable)) |
- |
0 |
|
Repeat Test |
| 15(Test for absence of odour and taste) |
- |
0 |
|
Repeat Test |
| 16(a)(Protection against access to live parts) |
- |
0 |
|
Repeated Test |
| 16(b)(Power input and current) |
- |
0 |
|
Repeated Test |
| 16 (c(Heating) |
- |
0 |
|
Repeated Test |
| 16(d)(Leakage current and electric strength at operating temperature) |
- |
0 |
|
Repeated Test |
| 16(e)(Moisture resistance) |
- |
0 |
|
Repeated Test |
| 16(f)(Leakage current and electric strength (high voltage after humidity)) |
- |
0 |
|
Repeated Test |
| 17(Packing) |
- |
1000 |
|
- |
| 18(Designation) |
- |
1000 |
|
- |
| 19(Instructions for Use and Maintenance) |
- |
4700 |
|
- |
| 20.3 (a)(Leakage Current Test) |
- |
0 |
|
Repeat Test |
| 20.3 (b)(Earth Continuity Test) |
- |
0 |
|
Repeat Test |
| 20.3 (c(Electric Strength Test) |
- |
0 |
|
Repeat Test |
|
- |
- Included w.e.f 21.05.2025 |
| 99 |
IS 2925 (1984) |
Specification for industrial safety helmets (Second Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Shell) |
- |
500 |
|
- |
| 3.2(Harness) |
- |
200 |
|
- |
| 3.3(Metal Parts) |
- |
2000 |
|
- |
| 4.1(Sizes) |
- |
500 |
|
- |
| 5.1(Shell) |
- |
100 |
|
- |
| 5.2(Harness) |
- |
1000 |
|
- |
| 5.3(Chin Strap or Nape Strap) |
- |
2000 |
|
- |
| 5.4(Lamp Bracket) |
- |
1000 |
|
- |
| 5.5(Cable Clip) |
- |
1000 |
|
- |
| 6.1(Workmanship & Finish) |
- |
100 |
|
- |
| 7.1(Mass) |
- |
500 |
|
- |
| 8.1(Shock Absorption Resistance) |
- |
1000 |
|
- |
| 8.2(Penetration Resistance) |
- |
1000 |
|
- |
| 8.3(Flamability Resistance) |
- |
1000 |
|
- |
| 8.4(Electrical Resistance) |
- |
1000 |
|
- |
| 8.5(Water Absorption) |
- |
1000 |
|
- |
| 8.6(Heat Resistance) |
- |
1000 |
|
- |
| 3.1(Shell) |
- |
0 |
|
Repeated Test |
| 3.2(Harness) |
- |
0 |
|
Repeated Test |
| 3.3(Metal Parts) |
- |
0 |
|
Repeated Test |
| 4.1(Sizes) |
- |
0 |
|
Repeated Test |
| 5.1(Shell) |
- |
0 |
|
Repeated Test |
| 5.2(Harness) |
- |
0 |
|
Repeated Test |
| 5.3(Chin Strap or Nape Strap) |
- |
0 |
|
Repeated Test |
| 5.4(Lamp Bracket) |
- |
0 |
|
Repeated Test |
| 5.5(Cable Clip) |
- |
0 |
|
Repeated Test |
| 6.1(Workmanship & Finish) |
- |
0 |
|
Repeated Test |
| 7.1(Mass) |
- |
0 |
|
Repeated Test |
| 8.1(Shock Absorption Resistance) |
- |
0 |
|
Repeated Test |
| 8.2(Penetration Resistance) |
- |
0 |
|
Repeated Test |
| 8.3(Flamability Resistance) |
- |
0 |
|
Repeated Test |
| 8.4(Electrical Resistance) |
- |
0 |
|
Repeated Test |
| 8.5(Water Absorption) |
- |
0 |
|
Repeated Test |
| 8.6(Heat Resistance) |
- |
0 |
|
Repeated Test |
| 5.2.1(Head Band) |
- |
1000 |
|
- |
| 5.3.1(Chin Strap) |
- |
1000 |
|
- |
| 5.3.2(Nape Strap) |
- |
1000 |
|
- |
|
- |
- - |
| 100 |
IS 17550 : PART 3 (2021) |
Household Refrigerating Appliance- Characteristics and test methods Part 3 Energy Consumption and volume |
- |
105000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| "Cl. No. 6 "("DETERMINATION OF ENERGY
CONSUMPTION") |
- |
7000 |
|
- |
| "Cl. No.4.8 & Annex H "(Determination Of Volume) |
- |
14000 |
|
- |
| "Cl. No. 6 "("DETERMINATION OF ENERGY
CONSUMPTION") |
- |
0 |
|
Repeat Test |
| "Cl. No. 6 "("DETERMINATION OF ENERGY
CONSUMPTION") |
- |
0 |
|
Repeat Test |
| 4.3(Defrost and Recovery Energy and temperature change) |
- |
14000 |
|
- |
| 4.4(Defrost Frequency) |
- |
14000 |
|
- |
| 4.5(Number of Test Points and Interpolations) |
- |
14000 |
|
- |
| 4.6(Load Processing Efficiency) |
- |
14000 |
|
- |
| 4.7(Specified Auxiliaries) |
- |
14000 |
|
- |
| 4.8(Volumn Determination) |
- |
0 |
|
Repeat Test |
| 6(Determination of Energy Consumption) |
- |
0 |
|
Repeat Test |
| Annex B(Determination of Steady state Power & Temperature) |
- |
14000 |
|
- |
| Annex C(Defrost and Recovery Energy and temperature change) |
- |
14000 |
|
- |
| Annex D(Defrost Interval) |
- |
14000 |
|
- |
| Annex E(Interpolation of Results) |
- |
14000 |
|
- |
| Annex F(Energy Consumption of specified auxiliaries) |
- |
14000 |
|
- |
| Annex G(Determination of Load Processing Efficiency) |
- |
14000 |
|
- |
| Annex H(Determination of Volume) |
- |
14000 |
|
- |
| "Cl. No.4.8 & Annex H "(Determination Of Volume) |
- |
0 |
|
Repeat Test |
| 4.2(Steady State Power Consumption) |
- |
14000 |
|
- |
|
- |
- Included w.e.f 21.05.2025 |
| 101 |
IS 17550 : PART 2 (2021) |
Household Refrigerating Appliance- Characteristics and test methods Part 2 Performance requirements |
- |
300000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. No. 6(Storage Test) |
- |
10000 |
|
- |
| Cl. No. 7(Cooling Capacity Test) |
- |
45000 |
|
- |
| Cl. No. 8(Freezing Capacity Test) |
- |
45000 |
|
- |
| Cl. No. 9("Automatic Ice-Making
Capacity Test") |
- |
45000 |
|
- |
| "Cl. No.4.6 & Annex A"(PULL-DOWN TEST) |
- |
35000 |
|
- |
| Cl. No.4.6(b) & Annex B("Wine Storage
Appliances And
Compartments;
Storage Test") |
- |
34000 |
|
- |
| Cl. No.4.6(C) & AnnexC("Temperature Rise
Test ") |
- |
45000 |
|
- |
| Cl. No.4.6(d) & Annex D("Water Vapour Condensation
Test ") |
- |
40000 |
|
- |
| Cl. No.4.6(d) & Annex D("Water Vapour Condensation
Test ") |
- |
0 |
|
Repeat Test |
| Cl. No. 6(Storage Test) |
- |
0 |
|
Repeat Test |
| Cl. No. 8(Freezing Capacity Test) |
- |
0 |
|
Repeat Test |
| Cl. No. 9("Automatic Ice-Making
Capacity Test") |
- |
0 |
|
Repeat Test |
| "Cl. No.4.6 & Annex A"(PULL-DOWN TEST) |
- |
0 |
|
Repeat Test |
| Cl. No.4.6(b) & Annex B("Wine Storage
Appliances And
Compartments;
Storage Test") |
- |
0 |
|
Repeat Test |
| Cl. No.4.6(C) & AnnexC("Temperature Rise
Test ") |
- |
0 |
|
Repeat Test |
| Cl. No.4.6(d) & Annex D("Water Vapour Condensation
Test ") |
- |
0 |
|
Repeat Test |
| 4.2(Storage test) |
- |
10000 |
|
- |
| 4.3(Cooling capacity test) |
- |
45000 |
|
- |
| 4.5(Automatic ice-making capacity test) |
- |
45000 |
|
- |
| 4.6(Other Tests) |
- |
154000 |
|
- |
| 6(Storage test) |
- |
0 |
|
Repeat Test |
| 7(Cooling capacity test) |
- |
0 |
|
Repeat Test |
| 8(Freezing capacity test) |
- |
0 |
|
Repeat Test |
| 9(Automatic ice-making capacity test) |
- |
0 |
|
Repeat Test |
| Annex A(Pull Down test) |
- |
35000 |
|
- |
| Annex B(Storage test of wine storage appliances and compartments) |
- |
34000 |
|
- |
| Annex C(Temperature Rise Test) |
- |
45000 |
|
- |
| Annex D(Water Vapour Condensation Test) |
- |
40000 |
|
- |
| 4.4(Freezing Capacity Test) |
- |
45000 |
|
- |
| 5(General Test Conditions) |
- |
1000 |
|
- |
|
- |
- Included w.e.f 21.05.2025 |
| 102 |
IS 302 : Part 2 : Sec 7 (2024) |
Safety of Household And Similar Electrical Appliances Part 2 Particular Requirements Section 7: Domestic Electric Clothes Washing Machines |
- |
46000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(GENERAL REQUIREMENT) |
- |
200 |
|
- |
| 6(CLASSIFICATION) |
- |
200 |
|
- |
| 7(MARKING AND INSTRUCTIONS) |
- |
500 |
|
- |
| 8(PROTECTION AGAINST ACCESS TO LIVE PARTS) |
- |
1000 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
1000 |
|
- |
| 11(HEATING) |
- |
1500 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1000 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
1500 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
3000 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
10000 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
1000 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
| 22(CONSTRUCTION) |
- |
1500 |
|
- |
| 23(INTERNAL WIRING) |
- |
1500 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
2000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
1000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
2000 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
1500 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
1600 |
|
- |
| 19.13(ABNORMAL OPERATION) |
- |
5000 |
|
- |
| 19.101(Abnormal Operation) |
- |
5000 |
|
- |
| 19.102(Abnormal Operation) |
- |
5000 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1000 |
|
- |
| 17("OVERLOAD PROTECTION OF
TRANSFORMERS AND ASSOCIATED CIRCUITS ") |
- |
2000 |
|
- |
| 17("OVERLOAD PROTECTION OF
TRANSFORMERS AND ASSOCIATED CIRCUITS ") |
- |
0 |
|
Repeat Test |
| 18(ENDURANCE) |
- |
2000 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
16000 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
10000 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
10000 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
10000 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
10000 |
|
- |
| 19.11.4.7(Harmonics) |
- |
10000 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
10000 |
|
- |
|
- |
- Included w.e.f 21.05.2025
Exclusion: Cl 19.11.4 (EMI/EMC tests) |
| 103 |
IS 9973 (1981) |
Specification for visor for scooter helmets |
- |
6700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Impact resistance) |
- |
300 |
|
- |
| 5.2(Penetration resistance) |
- |
400 |
|
- |
| 5.3(Flammability) |
- |
600 |
|
- |
| 5.4.1(Distortion) |
- |
200 |
|
- |
| 5.4.2(Spherical&Cylindral error) |
- |
900 |
|
- |
| 5.4.3(Prismatic Error) |
- |
900 |
|
- |
| 5.4.4(Diffuse transmittance) |
- |
800 |
|
- |
| 5.4.5(Light transmission) |
- |
800 |
|
- |
| 5.5(Field of Vision) |
- |
800 |
|
- |
| 7.0(Mass) |
- |
300 |
|
- |
| 5.1(Impact resistance) |
- |
0 |
|
Repeated Test |
| 5.2(Penetration resistance) |
- |
0 |
|
Repeated Test |
| 5.3(Flammability) |
- |
0 |
|
Repeated Test |
| 5.4.1(Distortion) |
- |
0 |
|
Repeated Test |
| 5.4.2(Spherical&Cylindral error) |
- |
0 |
|
Repeated Test |
| 5.4.3(Prismatic Error) |
- |
0 |
|
Repeated Test |
| 5.4.4(Diffuse transmittance) |
- |
0 |
|
Repeated Test |
| 5.4.5(Light transmission) |
- |
0 |
|
Repeated Test |
| 5.5(Field of Vision) |
- |
0 |
|
Repeated Test |
| 7.1(Mass) |
- |
0 |
|
Repeated Test |
| 3(Materials) |
- |
200 |
|
- |
| 4(Design) |
- |
200 |
|
- |
| 6.1(Workmanship and Finish) |
- |
100 |
|
- |
| 5.2.2(Cradle) |
- |
0 |
|
This clause Number is not mentioned in the standard. |
|
- |
- - |