1 |
IS 9997 (2023) |
ALUMINIUM ALLOY REDRAW RODS FOR ELECTRICAL PURPOSES - SPECIFICATION |
-- |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-5.1(General requirements) |
- |
500 |
|
- |
Cl-5.2(Redraw rods) |
- |
500 |
|
- |
Cl-6(Manufacture) |
- |
450 |
|
- |
Cl-7.1, Table-2 (i)(Silicon) |
- |
400 |
|
- |
Cl-7.1, Table-2 (ii)(Iron) |
- |
400 |
|
- |
Cl-7.1, Table-2 (iii)(Copper) |
- |
400 |
|
- |
Cl-7.1, Table-2 (iv)(Manganese) |
- |
400 |
|
- |
Cl-7.1, Table-2 (v)(Magnesium) |
- |
400 |
|
- |
Cl-7.1, Table-2 (vi)(Chromium) |
- |
400 |
|
- |
Cl-7.1, Table-2 (vii)(Zinc) |
- |
400 |
|
- |
Cl-7.1, Table-2 (viii)(Boron) |
- |
400 |
|
- |
Cl-7.1, Table-2 (ix)(Vanadium + Titanium) |
- |
400 |
|
- |
Cl-7.1, Table-2 (x)(Other each) |
- |
400 |
|
- |
Cl-7.1, Table-2 (xi)(Others total) |
- |
400 |
|
- |
Cl-7.1, Table-2 (xii)(Aluminium) |
- |
400 |
|
- |
Cl-8.1, Table-3(UTS (MPa)) |
- |
2000 |
|
- |
Cl-8.1, Table-3(Elongation (%) - On 250 mm gauge length) |
- |
1000 |
|
- |
Cl-8.1, Table-3(Resistivity (micro ohm.cm) at 20 oC) |
- |
1000 |
|
- |
Cl-8.1, Table-3(Conductivity (%) (IACS)) |
- |
1000 |
|
- |
Cl-9(Electrical resistivity) |
- |
2000 |
|
- |
Cl-10(Diameter and Permissible Variations) |
- |
650 |
|
- |
Cl-11(Joints) |
- |
400 |
|
- |
Cl-12(Finish and freedom from defects) |
- |
400 |
|
- |
Cl-16(Marking) |
- |
300 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f 03.03.2025 |
2 |
IS 7404 : Part 1 (1991) |
Paper covered copper conductors - Specification: Part 1 round conductors (First Revision) |
- |
-
|
12000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General test conditions ) |
- |
500 |
|
- |
5(Conductor ) |
- |
500 |
|
- |
5.1(Material ) |
- |
500 |
|
- |
5.2(Diameter ) |
- |
2500 |
|
- |
6.1(Grade of Paper) |
- |
500 |
|
- |
7(Application of paper ) |
- |
500 |
|
- |
8(Overall diameter and increase in diameter ) |
- |
2500 |
|
- |
8.1(Double Paper Covering Ordinary (0) and Fine (F)) |
- |
500 |
|
- |
8.2(Multiple Paper Covering Special (S)) |
- |
1000 |
|
- |
8.3(Measuring Equipment) |
- |
1500 |
|
- |
8.4(Measuring Method) |
- |
1000 |
|
- |
9(Packing and marking ) |
- |
500 |
|
- |
4(General test conditions ) |
- |
500 |
|
- |
5(Conductor ) |
- |
500 |
|
- |
5.1(Material ) |
- |
500 |
|
- |
5.2(Diameter ) |
- |
2500 |
|
- |
6.1(Grade of Paper) |
- |
500 |
|
- |
7(Application of paper ) |
- |
500 |
|
- |
8(Overall diameter and increase in diameter ) |
- |
2500 |
|
- |
8.1(Double Paper Covering Ordinary (0) and Fine (F)) |
- |
500 |
|
- |
8.2(Multiple Paper Covering Special (S)) |
- |
1000 |
|
- |
8.3(Measuring Equipment) |
- |
1500 |
|
- |
8.4(Measuring Method) |
- |
1000 |
|
- |
9(Packing and marking ) |
- |
500 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included.w.e.f.15.01.2025 |
3 |
IS 15884 (2024) |
ALTERNATING CURRENT DIRECT CONNECTED STATIC PREPAYMENT METERS FOR ACTIVE ENERGY CLASS 1 AND 2 SPECIFICATION |
-- |
-
|
600000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(GENERAL REQUIREMENTS) |
- |
5000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.2.1(Spring Hammer Test) |
- |
5000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.2.2(Shock Test) |
- |
25000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.2.3(Vibration Test) |
- |
25000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.2.4(Test of Resistance to Heat and Fire) |
- |
5000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.2.5(Tests of Protection against Penetration of Dust and Water) |
- |
15000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.3.1(Dry Heat Test) |
- |
15000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.3.2(Cold Test) |
- |
170000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.3.3(Damp Heat Cyclic Test) |
- |
22000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.1(Test of Power Consumption) |
- |
10000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.2(Test of influence of voltage dips and interruptions) |
- |
15000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.3(Test of Influence of Short-Time Overcurrent) |
- |
130000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.4(Test of Influence of Self-Heating) |
- |
5000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.5(Test of Influence of Heating) |
- |
7000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.6.2(Impulse voltage test) |
- |
7000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.6.3(a.c. voltage test) |
- |
7000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.6.4(Insulation resistance test) |
- |
5000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.5.2(Test of Immunity to Electrostatic Discharges) |
- |
15000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.5.3(Test of Immunity to Electromagnetic HF Fields) |
- |
80000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.5.4(Fast Transient Burst Test) |
- |
15000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.5.5(Radio Interference Measurement) |
- |
40000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.5.6(Surge Immunity Test) |
- |
20000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.6.2(Test of Influence Quantities) |
- |
10000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.6.3(Test of No-Load Condition) |
- |
10000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.6.4(Test of Starting Condition) |
- |
10000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.6.5(Test of Meter Constant) |
- |
12000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.6.6(Interpretation of Test Results) |
- |
15000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.7(Test of the Load Switch operation for payment function) |
- |
10000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.8(Test of Charging Functions) |
- |
5000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.9(Interruption and Restoration of the Load for Emergency Credit Facility (if applicable)) |
- |
10000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.10(Tests of the Load Switch operation at Different Voltages and Temperature) |
- |
14000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
6(FUNCTIONAL REQUIREMENTS) |
- |
14000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
4(GENERAL REQUIREMENTS) |
- |
5000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.2.1(Spring Hammer Test) |
- |
5000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.2.2(Shock Test) |
- |
25000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.2.3(Vibration Test) |
- |
25000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.2.4(Test of Resistance to Heat and Fire) |
- |
5000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.2.5(Tests of Protection against Penetration of Dust and Water) |
- |
15000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.3.1(Dry Heat Test) |
- |
15000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.3.2(Cold Test) |
- |
170000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.3.3(Damp Heat Cyclic Test) |
- |
22000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.1(Test of Power Consumption) |
- |
10000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.2(Test of influence of voltage dips and interruptions) |
- |
15000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.3(Test of Influence of Short-Time Overcurrent) |
- |
130000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.4(Test of Influence of Self-Heating) |
- |
5000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.5(Test of Influence of Heating) |
- |
7000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.6.2(Impulse voltage test) |
- |
7000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.6.3(a.c. voltage test) |
- |
7000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.6.4(Insulation resistance test) |
- |
5000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.5.2(Test of Immunity to Electrostatic Discharges) |
- |
15000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.5.3(Test of Immunity to Electromagnetic HF Fields) |
- |
80000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.5.4(Fast Transient Burst Test) |
- |
15000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.5.5(Radio Interference Measurement) |
- |
40000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.5.6(Surge Immunity Test) |
- |
20000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.6.2(Test of Influence Quantities) |
- |
10000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.6.3(Test of No-Load Condition) |
- |
10000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.6.4(Test of Starting Condition) |
- |
10000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.6.5(Test of Meter Constant) |
- |
12000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.6.6(Interpretation of Test Results) |
- |
15000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.7(Test of the Load Switch operation for payment function) |
- |
10000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.8(Test of Charging Functions) |
- |
5000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.9(Interruption and Restoration of the Load for Emergency Credit Facility (if applicable)) |
- |
10000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.10(Tests of the Load Switch operation at Different Voltages and Temperature) |
- |
14000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
6(FUNCTIONAL REQUIREMENTS) |
- |
14000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
4(GENERAL REQUIREMENTS) |
- |
5000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.2.1(Spring Hammer Test) |
- |
5000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.2.2(Shock Test) |
- |
25000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.2.3(Vibration Test) |
- |
25000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.2.4(Test of Resistance to Heat and Fire) |
- |
5000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.2.5(Tests of Protection against Penetration of Dust and Water) |
- |
15000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.3.1(Dry Heat Test) |
- |
15000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.3.2(Cold Test) |
- |
170000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.3.3(Damp Heat Cyclic Test) |
- |
22000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.1(Test of Power Consumption) |
- |
10000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.2(Test of influence of voltage dips and interruptions) |
- |
15000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.3(Test of Influence of Short-Time Overcurrent) |
- |
130000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.4(Test of Influence of Self-Heating) |
- |
5000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.5(Test of Influence of Heating) |
- |
7000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.6.2(Impulse voltage test) |
- |
7000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.6.3(a.c. voltage test) |
- |
7000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.4.6.4(Insulation resistance test) |
- |
5000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.5.2(Test of Immunity to Electrostatic Discharges) |
- |
15000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.5.3(Test of Immunity to Electromagnetic HF Fields) |
- |
80000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.5.4(Fast Transient Burst Test) |
- |
15000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.5.5(Radio Interference Measurement) |
- |
40000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.5.6(Surge Immunity Test) |
- |
20000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.6.2(Test of Influence Quantities) |
- |
10000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.6.3(Test of No-Load Condition) |
- |
10000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.6.4(Test of Starting Condition) |
- |
10000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.6.5(Test of Meter Constant) |
- |
12000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.6.6(Interpretation of Test Results) |
- |
15000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.7(Test of the Load Switch operation for payment function) |
- |
10000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.8(Test of Charging Functions) |
- |
5000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.9(Interruption and Restoration of the Load for Emergency Credit Facility (if applicable)) |
- |
10000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
5.10(Tests of the Load Switch operation at Different Voltages and Temperature) |
- |
14000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
6(FUNCTIONAL REQUIREMENTS) |
- |
14000 |
|
Complete Testing Charge = 350000/- for UC1
Complete Testing Charge = 600000/- for UC1 & UC2 |
|
Complete
|
|
31 Dec, 2026 |
- Included.w.e.f.15.01.2025 |
4 |
IS 17018 : Part 1 (2022) |
Solar Photovoltaic Water Pumping Systems Part 1 Centrifugal Pumps Specification |
- |
-
|
55000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.2.1(Observation) |
- |
100 |
|
- |
4.2.2(Observation) |
- |
100 |
|
- |
4.2.3(Provision for remote monitoring) |
- |
100 |
|
- |
4.3.1(STC Power (Wp)) |
- |
100 |
|
- |
4.3.2(Observation) |
- |
100 |
|
- |
4.3.3(Observation) |
- |
100 |
|
- |
4.3.4(Observation) |
- |
100 |
|
- |
4.3.5(Observation) |
- |
100 |
|
- |
4.3.6(Salt mist corrosion test) |
- |
100 |
|
VERIFICATION ONLY |
4.3.7(Observation) |
- |
100 |
|
- |
4.3.8(STC Power (Wp)) |
- |
100 |
|
- |
4.3.9(STC Power (Wp)) |
- |
100 |
|
- |
4.3.10(Solar Photo Voltaic (SPV) Array) |
- |
100 |
|
- |
4.4.1(Motor- Pump set) |
- |
100 |
|
- |
4.4.2(Observation) |
- |
100 |
|
- |
4.4.3(Motor- Pump set
Material) |
- |
100 |
|
- |
4.5.1(Observation) |
- |
100 |
|
- |
4.5.2(Observation) |
- |
100 |
|
- |
4.5.3(Observation) |
- |
100 |
|
- |
4.5.1(Module Mounting Structures and Tracking system) |
- |
100 |
|
- |
4.5.4(Design of MMS) |
- |
100 |
|
- |
4.6.1(SPV Pump Controller) |
- |
100 |
|
- |
4.6.2(Observation) |
- |
100 |
|
- |
4.6.3(Observation) |
- |
100 |
|
- |
4.6.4(Observation) |
- |
100 |
|
- |
6.2(Performance (with Sun simulator)) |
- |
100 |
|
- |
4.6.5(Observation) |
- |
100 |
|
- |
4.7.1(Earthling arrangement) |
- |
100 |
|
- |
4.7.4(Observation) |
- |
100 |
|
- |
6.1(Observation) |
- |
8000 |
|
- |
7.1(Litre/Wp, LPD, Head) |
- |
15000 |
|
- |
7.2(Observation) |
- |
3700 |
|
- |
7.2(Observation) |
- |
3700 |
|
- |
8.1.1(Observation) |
- |
100 |
|
- |
8.1.2(Observation) |
- |
100 |
|
- |
9(Observation) |
- |
100 |
|
- |
5(Litre, Litre/Wp) |
- |
25000 |
|
- |
6(TESTS FOR HYDRAULIC AND ELECTRICAL PERFORMANCE OF
PUMPSET) |
- |
100 |
|
- |
4.2.1(Observation) |
- |
100 |
|
- |
4.2.2(Observation) |
- |
100 |
|
- |
4.2.3(Provision for remote monitoring) |
- |
100 |
|
- |
4.3.1(STC Power (Wp)) |
- |
100 |
|
- |
4.3.2(Observation) |
- |
100 |
|
- |
4.3.3(Observation) |
- |
100 |
|
- |
4.3.4(Observation) |
- |
100 |
|
- |
4.3.5(Observation) |
- |
100 |
|
- |
4.3.6(Salt mist corrosion test) |
- |
100 |
|
VERIFICATION ONLY |
4.3.7(Observation) |
- |
100 |
|
- |
4.3.8(STC Power (Wp)) |
- |
100 |
|
- |
4.3.9(STC Power (Wp)) |
- |
100 |
|
- |
4.3.10(Solar Photo Voltaic (SPV) Array) |
- |
100 |
|
- |
4.4.1(Motor- Pump set) |
- |
100 |
|
- |
4.4.2(Observation) |
- |
100 |
|
- |
4.4.3(Motor- Pump set
Material) |
- |
100 |
|
- |
4.5.1(Observation) |
- |
100 |
|
- |
4.5.2(Observation) |
- |
100 |
|
- |
4.5.3(Observation) |
- |
100 |
|
- |
4.5.1(Module Mounting Structures and Tracking system) |
- |
100 |
|
- |
4.5.4(Design of MMS) |
- |
100 |
|
- |
4.6.1(SPV Pump Controller) |
- |
100 |
|
- |
4.6.2(Observation) |
- |
100 |
|
- |
4.6.3(Observation) |
- |
100 |
|
- |
4.6.4(Observation) |
- |
100 |
|
- |
6.2(Performance (with Sun simulator)) |
- |
100 |
|
- |
4.6.5(Observation) |
- |
100 |
|
- |
4.7.1(Earthling arrangement) |
- |
100 |
|
- |
4.7.4(Observation) |
- |
100 |
|
- |
6.1(Observation) |
- |
8000 |
|
- |
7.1(Litre/Wp, LPD, Head) |
- |
15000 |
|
- |
7.2(Observation) |
- |
3700 |
|
- |
7.2(Observation) |
- |
3700 |
|
- |
8.1.1(Observation) |
- |
100 |
|
- |
8.1.2(Observation) |
- |
100 |
|
- |
9(Observation) |
- |
100 |
|
- |
5(Litre, Litre/Wp) |
- |
25000 |
|
- |
6(TESTS FOR HYDRAULIC AND ELECTRICAL PERFORMANCE OF
PUMPSET) |
- |
100 |
|
- |
4.2.1(Observation) |
- |
- |
|
- |
4.2.2(Observation) |
- |
- |
|
- |
4.2.3(Provision for remote monitoring) |
- |
- |
|
- |
4.3.1(STC Power (Wp)) |
- |
- |
|
- |
4.3.2(Observation) |
- |
- |
|
- |
4.3.3(Observation) |
- |
- |
|
- |
4.3.4(Observation) |
- |
- |
|
- |
4.3.5(Observation) |
- |
- |
|
- |
4.3.6(Salt mist corrosion test) |
- |
- |
|
- |
4.3.7(Observation) |
- |
- |
|
- |
4.3.8(STC Power (Wp)) |
- |
- |
|
- |
4.3.9(STC Power (Wp)) |
- |
- |
|
- |
4.3.10(Solar Photo Voltaic (SPV) Array) |
- |
- |
|
- |
4.4.1(Motor- Pump set) |
- |
- |
|
- |
4.4.2(Observation) |
- |
- |
|
- |
4.4.3(Motor- Pump set
Material) |
- |
- |
|
- |
4.5.1(Observation) |
- |
- |
|
- |
4.5.2(Observation) |
- |
- |
|
- |
4.5.3(Observation) |
- |
- |
|
- |
4.5.1(Module Mounting Structures and Tracking system) |
- |
- |
|
- |
4.5.4(Design of MMS) |
- |
- |
|
- |
4.6.1(SPV Pump Controller) |
- |
- |
|
- |
4.6.2(Observation) |
- |
- |
|
- |
4.6.3(Observation) |
- |
- |
|
- |
4.6.4(Observation) |
- |
- |
|
- |
6.2(Performance (with Sun simulator)) |
- |
- |
|
- |
4.6.5(Observation) |
- |
- |
|
- |
4.7.1(Earthling arrangement) |
- |
- |
|
- |
4.7.4(Observation) |
- |
- |
|
- |
6.1(Observation) |
- |
- |
|
- |
7.1(Litre/Wp, LPD, Head) |
- |
- |
|
- |
7.2(Observation) |
- |
- |
|
- |
7.2(Observation) |
- |
- |
|
- |
8.1.1(Observation) |
- |
- |
|
- |
8.1.2(Observation) |
- |
- |
|
- |
9(Observation) |
- |
- |
|
- |
5(Litre, Litre/Wp) |
- |
- |
|
- |
6(TESTS FOR HYDRAULIC AND ELECTRICAL PERFORMANCE OF
PUMPSET) |
- |
- |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included.w.e.f.13.01.2025 |
5 |
IS 3854 (1997) |
Switches for domestic and similar purposes - Specification (Second Revision) |
- |
-
|
32000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8(Marking) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
8(Marking) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
8(Marking) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
8(Marking) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
8(Marking) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
8(Marking) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
8(Marking) |
- |
50 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
8(Marking) |
- |
50 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
8.9(Marking) |
- |
50 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
8(Marking) |
- |
25 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
6(Rating) |
- |
25 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
6(Rating) |
- |
25 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
7(Classification) |
- |
25 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
7(Classification) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
7(Classification) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
7(Classification) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
7(Classification) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
7(Classification) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
7(Classification) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
7(Classification) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
7(Classification) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
10(Protection against Electric Shock) |
- |
50 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
11.1(Provision for earthing) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12(Terminals) |
- |
50 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.2.1(Terminals) |
- |
50 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12(Terminals) |
- |
50 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.2.2(Connection of conductor) |
- |
50 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.2.3(Mechanical strength of terminals) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.2.3(Mechanical strength of terminals) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.2.4(Resistance to corrosion) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.2.4(Resistance to corrosion) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.2.5(Undue damage to conductor) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.2.7(Insertion of conductor) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.2.9(Locking against accidental loosening) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.2.11(Distance between screw and conductor) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.2.11(Distance between screw and conductor) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.2(Screwless terminals) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.3(Connectin of conductor) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.4(Material of terminals) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.5(Clamping) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.5(Clamping) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.7(v) Interconnection of conductors [Cl. 12.3.7]) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.7(v) Interconnection of conductors [Cl. 12.3.7]) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.11(vi) Electrical & Thermal Stresses [Cl 12.3.11]) |
- |
700 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.11(vi) Electrical & Thermal Stresses [Cl 12.3.11]) |
- |
700 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.12(vii) Deflection Stresses [Cl. 12.3.12]) |
- |
700 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.1(a) Insulating lining, barriers and the like [Cl 13.1]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.2(b) Construction of switch [Cl 13.2]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.2(i) Installation Test) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.3(c) Covers,cover plates and actuating members [Cl 13.3]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.4(d) Ordinary switches [Cl 13.4]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.5(e) Rotary switches [Cl 13.5]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.6(f) Screws and other means [Cl 13.6]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.7(g) Combination of switches or switches and socket outlets [Cl 13.7]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.8(h) Assessories combined with switches [Cl. 13.8]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.9(j) Switches other than ordinary switches [Cl. 13.9]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.9(j) Switches other than ordinary switches [Cl. 13.9]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.9(j) Switches other than ordinary switches [Cl. 13.9]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.9(j) Switches other than ordinary switches [Cl. 13.9]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.9(j) Switches other than ordinary switches [Cl. 13.9]) |
- |
50 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.9(j) Switches other than ordinary switches [Cl. 13.9]) |
- |
50 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.1(k) Switches to be installed in a box [Cl. 13.10]) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.11(l) Surface type switches other than ordinary switch [Cl. 13.11]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.12, 13.13, 13.14(m) Inlet opening [Cl. 13.12.13.13 & 13.14]) |
- |
300 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.15(q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
50 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.15(q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
50 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.15(q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
50 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.15(q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
50 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
14(Mechanism [Cl. 14]) |
- |
50 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
14.4(Mechanism) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
15.1(Resistance to Ageing, to Harmful Ingress of water and to Humidity [Cl. 15]: Resistance to Ageing, [Cl. 15.1]) |
- |
350 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
15.2(b)Resistance to Harmful ingress of water [Cl. 15.2]) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
15.2(b)Resistance to Harmful ingress of water [Cl. 15.2]) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
15.3(c) Resistance to Humidity [Cl. 15.3]) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
16.1(Insulation resistance [Cl. 16.1]) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
16.2( Electric Strength [Cl. 16.2]) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
17(Temperature- rise [Cl. 17]) |
- |
350 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
18(Marking and breaking Capacity[Cl. 18]) |
- |
350 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
18(Marking and breaking Capacity[Cl. 18]) |
- |
350 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
19(Normal Operation [Cl. 19] a) General & Operation) |
- |
700 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
19(b) Electric Strength) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
19(c)Temperature-rise ) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
14.3(d)Test for arcing and sparking [Cl 14.3]) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
19.2(Normal Operation (For AX type Switches) [Cl. 19.2]) |
- |
400 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
19.2(Normal Operation (For AX type Switches) [Cl. 19.2]) |
- |
400 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20(Mechanical Strength Test [Cl. 20]) |
- |
50 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
21(Resistance to Heat [Cl.21]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
21(Resistance to Heat [Cl.21]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
21(Resistance to Heat [Cl.21]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
22(Screw, Current Carrying Part And Connection [Cl.22]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
22.1(i) Screw & Nuts [Cl.22.1]) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
22.4(ii) Screw & rivets [Cl . 22.4]) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
22.3(iii) Electrical Connections [Cl.22.3]) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
22.5(iv) Current carrying part [Cl.22.5]) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
23.2(Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
23(Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
23(Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
24.1.1(Resistance to Abnormal Heat & Fire [Cl.24.1] [Glow Wire Test] [Cl.24.1.1]) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
24.2(Resistance to tracking [For Switch other than ordinary] [Cl.24.2]) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
24.2(Resistance to tracking [For Switch other than ordinary] [Cl.24.2]) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
25 of IS 3854 : 1997(Resistance to rusting) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
11.3(Provision for earthing) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
11.2(Provision for earthing) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.9(Screwless terminal fixing) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.8(Screwless terminals design) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.1(Screwless terminals) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
14.6(Mechanism) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
14.5(Mechanism) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
16.3(Flash test) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.8(Mechanical Strength Test) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.7(Mechanical Strength Test) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.6(Mechanical Strength Test) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.5(Mechanical Strength Test) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.4(Mechanical Strength Test) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.3(Mechanical Strength Test) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.2(Mechanical Strength Test) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.1(Mechanical Strength Test) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
21.2(Resistance to Heat) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
21.1(Resistance to Heat) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
24.1(Resistance of insulating material to abnormal heat, to fire and to tracking
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
24(Resistance of insulating material to abnormal heat, to fire and to tracking
) |
- |
50 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
23.2(Creepage distances,
clearances & distance through
sealing compound
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
23.1(Creepage distances,
clearances & distance through
sealing compound
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
22.7(Screws, current
carrying parts and connections
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
22.6(Screws, current
carrying parts and connections
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
22.5(Screws, current
carrying parts and connections
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
22.4(Screws, current
carrying parts and connections
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
22.3(Screws, current
carrying parts and connections
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
22.2(Screws, current
carrying parts and connections
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
22.1(Screws, current
carrying parts and connections
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
22.2(Measurement and manual test) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
22.6(Inspection and chemical analysis) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
21.3(Resistance to heat
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
21.2(Resistance to heat
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
21.1(Resistance to heat
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.9(Mechanical
strength
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.8(Mechanical
strength
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.7(Mechanical
strength
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.6 & 24.4.2(Mechanical
strength
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.6 & 24.4.1(Mechanical
strength
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.5 & 24.4.2(Mechanical
strength
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.5 & 24.4.1(Mechanical
strength
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.4.2(Mechanical
strength
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.4.1(Mechanical
strength
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.4(Mechanical
strength
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.3(Mechanical
strength
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
20.2(Mechanical
strength
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
19.2(Normal operation) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
19.1(Normal operation) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
18.2(Making and breaking capacity ) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
18.1(Making and breaking capacity ) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
16.3(Insulation
resistance and electric strength
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
16(Insulation
resistance and electric strength
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
15.3(Resistance to ageing, to harmful ingress of water and to humidity
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
15.2.3(Resistance to ageing, to harmful ingress of water and to humidity
) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
15.2.2(Resistance to ageing, to harmful ingress of water and to humidity
) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
15.2.1(Resistance to ageing, to harmful ingress of water and to humidity
) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
15.2(Resistance to ageing, to harmful ingress of water and to humidity
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
15.1(Resistance to ageing, to harmful ingress of water and to humidity
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
15(Resistance to ageing, to harmful ingress of water and to humidity
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
14.6(Mechanism) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
14.5(Mechanism) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
14.4(Mechanism) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
14.3(Mechanism) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
14.2(Mechanism) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
14.1(Mechanism) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.15.2(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.15.1(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.15(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.14(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.13(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.12(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.11(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.1(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.9(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.8(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.7(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.6(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.5(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.4(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.3.3(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.3.2(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.3.1(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.3(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.2(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.1(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13(Constructional
requirements
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.12(Terminals) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.11.b(Terminals) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.11.a(Terminals) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.10(Terminals) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.9(Terminals) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.8(Terminals) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.6(Terminals) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.1(Terminals) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3(Terminals) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.2.12(Terminals) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.2.10(Terminals) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.2.8(Terminals) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.2.10(Terminals) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.2.8(Terminals) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.2.6(Terminals) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.2(Terminals) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.1(Terminals) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
11.4(Provision for earthing) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
11.3(Provision for earthing) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
11.2(Provision for earthing) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
11.1(Provision for earthing) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
10.7(Protection against electric shock
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
10.6(Protection against electric shock
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
10.5(Protection against electric shock
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
10.4(Protection against electric shock
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
10.3.2(Protection against electric shock
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
10.3.1(Protection against electric shock
) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
10.3(Protection against electric shock
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
10.2(Protection against electric shock
) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
10.1(Protection against electric shock
) |
- |
200 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
8.1(Marking) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
8.8(Marking) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
8.7(Marking) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
8.6(Marking) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
8.5(Marking) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
8.4(Marking) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
8.3(Marking) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
8.1(Marking) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
7.2(Classification) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
7.1.8(Classification) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
7.1.7(Classification) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
7.1.6(Classification) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
7.1.5(Classification) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
7.1.4(Classification) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
7.1.3(Classification) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
7.1.2(Classification) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
7.1.1(Classification) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
7.1(Classification) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
6.2(Ratings) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
6.1(Ratings) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
6(Ratings) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
25(Resistance to Rusting) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.2.6(Terminals, Qualitative) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.1(Terminals, Qualitative) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.6(Terminals, Qualitative) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
12.3.10(Terminals, Qualitative) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
13.12(Qualitative) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
14(Mechanism) |
- |
100 |
|
For BIS Samples 1.5 times of BIS Testing Charges and Others Upto 10Amp = 10000Rs, Above 10Amp upto 20Amp = 15000Rs, Above 20Amp upto & including 32Amp= 20000Rs,Above 32Amp = 32000Rs |
|
Complete
|
|
31 Dec, 2026 |
- - |
6 |
IS 17048 (2018) |
Halogen free flame retardant (HFFR) cables for working voltages up to and including 1 100 Volts - Specification |
- |
-
|
180000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1.1 a) (Conductor : Material ) |
- |
250.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.1.1 b) (Material : Seperator tape ) |
- |
250.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.1.1 d) , 11.1, 12.1, 13.1,14.1(Class of conductor ) |
- |
250.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.1.1 e) (Shape of conductor ) |
- |
500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.1.1 f) (Nominal size of conductor ) |
- |
500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.2.1, 11.2, 12.2, 13.2, 14.2(Insulation : Material ) |
- |
250.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.2.2, 11.2, 12.2, 13.2, 14.2(Insulation : Application ) |
- |
250.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.2.3,11.2, 12.2, 13.2(Thickness of insulation - Avearge : IS 10810 ( Part 6 )) |
- |
2500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.2.3, 11.2, 12.2, 13.2, 14.2(Thickness of insulation - miniumum : IS 10810 ( Part 6 )) |
- |
1500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.2.4(Insulation : Tensile stregth ( Before ageing)-IS 10810 (Part 7) ) |
- |
3000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.2.4(Insulation : Elongation ( Before ageing) -IS 10810 (Part 7)) |
- |
1500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.2.4(Insulation : Tensile stregth ( After ageing) - IS 10810 (Part 7) ) |
- |
3000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.2.5(Insulation : Tensile stregth variation ( After ageing) - IS 10810 (Part 7) ) |
- |
2500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.2.4(Insulation : Elongation (after ageing) - IS 10810 (Part 7) ) |
- |
2500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.2.5(Insulation : Elongation variation (after ageing) - IS 10810 (Part 7) ) |
- |
1500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.3(Fillers) |
- |
500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.4(Binder Tape) |
- |
500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.5.1,13.4, 14.4(Sheath : Compound ) |
- |
500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.5.2, 13.4, 14.4(Sheath : Application) |
- |
500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.5.3,13.4, 14.4(Thickness of sheath - Average : IS 10810 (Part 6)) |
- |
2000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.5.3,13.4, 14.4(Thickness of sheath - Minimum : IS 10810 (Part 6)) |
- |
500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.5.4, 13.4(Sheath : Tensile stregth ( Before ageing)-IS 10810 (Part 7) ) |
- |
1500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.5.4,13.4(Sheath : Elongation ( Before ageing) -IS 10810 (Part 7)) |
- |
1500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.5.4, 13.4, 14.4(Sheath : Tensile stregth ( After ageing) - IS 10810 (Part 7) ) |
- |
1500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.5.5, 13.4, 14.4(Sheath : Tensile stregth variation ( After ageing) - IS 10810 (Part 7) ) |
- |
1500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.5.4, 13.4, 14.4(Sheath : Elongation (after ageing) - IS 10810 (Part 7) ) |
- |
1500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.5.5, 11.3, 12.3, 13.6, 14.6(Overall Dimensions) |
- |
1000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.5.5.1, 11.3, 12.3,13.5, 14.5(Ovality) |
- |
1000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.5.6, 13.4(Colour of Sheath) |
- |
500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.1(High Voltage Test (at Room Temperature)) |
- |
10000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.3(Flammability Test- IS 10810 (Part 53).) |
- |
2000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.4(Oxygen Index Test- IS 10810 (Part 58)) |
- |
5000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.5(Temperature Index-IS 10810 (Part 64).) |
- |
5000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.6(Smoke Density-IS 10810 (Part 63).) |
- |
5000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.7(Assessment of Halogen- Table 1 of Annex D) |
- |
10000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.1(Persulphate Test- IS 10810 (Part 4).) |
- |
3000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.11(Flame Retardant Test- IS 10810 (Part 61),) |
- |
7000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.12(Hot Set Test- IS 10810 (Part 30).) |
- |
3000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.12(Permanent Set - IS 10810 (Part 30).) |
- |
1000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.13(Water Immersion Test (Effect of Water on Sheath) : Tensile strength -IS 10810 (Part 7).) |
- |
5000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.13(Water Immersion Test (Effect of Water on Sheath) : Elogation -IS 10810 (Part 7).) |
- |
5000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.14(Ozone Resistance Test -IS 10810 (Part 13 )) |
- |
12000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.15(Cold Bend Test-IS 10810 (Part 20).) |
- |
1500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.16(Cold Impact Test- IS 10810 (Part 21).) |
- |
1500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
6.1, Table 1(CORE IDENTIFICATION) |
- |
500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
6.2(Core Identification by Numbers) |
- |
500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
6.2.1(Preferred Arrangement of Marking) |
- |
500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
6.2.2(Durability) |
- |
500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
7.0(CABLE CODE) |
- |
150.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
9.0( IDENTIFICATION) |
- |
150.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
10.1(Packing ) |
- |
150.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
10.2(marking) |
- |
150.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
10.2.1(Standards marking) |
- |
150.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
13.3, 14.3(assembly of cores ) |
- |
150.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
6.1(General Requirements) |
- |
150.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
6.1.1(Colour Combination Green Yellow) |
- |
150.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
12.1(Conductor) |
- |
150.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
12.2, Table 4(insulation) |
- |
150.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
Table 2 ,( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )(Insulation Resistance) |
- |
2500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
"Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Conductor Resistance) |
- |
2500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
Table 2 , Clause .5.13(Water immersion test (Effect of water on sheath) - TS Variation of Sheath) |
- |
10000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
Table 2 , Clause 5.13(Water immersion test (Effect of water on sheath) - Elongation Variation of Sheath) |
- |
2500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
"Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Hot Deformation) |
- |
2500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
Table 2, III.a.ii(Annealing test (for Cu,
before stranding)) |
- |
2500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
Table 2, II.a, b(Wrapping test before
stranding (for Al)) |
- |
1500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
Table 4(Copper Purity test) |
- |
2500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.3.1 (e)(Fluorine content test (Fillers)) |
- |
7000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.3.1 (d)(Presence of fluorine test (Fillers)) |
- |
7000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.3.1 (c)(Conductivity test (Fillers)) |
- |
500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.3.1 (b)(pH test (Fillers)) |
- |
2500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
4.3.1 (a)(HCl test (Fillers)) |
- |
2500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.7 (a)(HCl test (Assessment of halogen test)) |
- |
5000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.7 (b)(pH test (Assessment of halogen test)) |
- |
2500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.7 (c)(Conductivity test (Assessment of halogen test)) |
- |
2500.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.7 (d)(Presence of fluorine test (Assessment of halogen test)) |
- |
5000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
5.7 (e)(Fluorine content test (Assessment of halogen test)) |
- |
5000.00 |
|
single core(HFFR)insulated(unsheathed)cables Rs. 93K for cat. 01&02,Rs 85K for cat. 03&04.single core(HFFR)insulated & sheathed cables Rs 1,60,000 for cat. 01&02,Rs 1,50,000 for cat. 03&04.Multi core(HFFR)insulated & sheathed cable Rs 1,80,800 (all core) |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 13.06.2024 |
7 |
IS 16444 : Part 2 (2017) |
AC static transformer operated watthour and var - Hour smart meters, class 0.2 S, 0.5 S and 1.0 S: Part 2 specification transformer operated smart meters |
- |
-
|
210000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.10.6((9.5 of IS 14697 ) Insulation Requirement ) |
- |
1000 |
|
- |
6.10.6((9.5 of IS 14697 ) Insulation Rtequirement ) |
- |
1000 |
|
- |
6.10.6((9.5 of IS 14697 ) Insulation Rtequirement ) |
- |
1000 |
|
- |
6.10.6((9.5 of IS 14697 ) Insulation Rtequirement ) |
- |
1000 |
|
- |
6.12(Test on limits of error) |
- |
5500 |
|
- |
6.12(Test of meter constant) |
- |
1000 |
|
- |
6.12(Test of starting condition) |
- |
2000 |
|
- |
6.12(Test of no-load condition) |
- |
1000 |
|
- |
6.12((11 of IS 14697 ) Accuracy Requirement ) |
- |
1000 |
|
- |
6.12(Test of ambient temperature influence) |
- |
2000 |
|
- |
6.12(Test of repeatability of error) |
- |
3000 |
|
- |
6.12(Test of influence quantities) |
- |
2000 |
|
- |
6.12(Voltage Variation) |
- |
1000 |
|
- |
6.12(Frequency Variation) |
- |
1000 |
|
- |
6.12(Waveform 10% of 3rd Harmonics) |
- |
500 |
|
- |
6.12(Reversed Phase Sequence) |
- |
500 |
|
- |
6.12(Voltage Unbalanced) |
- |
500 |
|
- |
6.12(Continuous Magnetic Induction of External Origin 67 milli Tesla) |
- |
500 |
|
- |
6.12(Continuous Magnetic Induction of External Origin 0.2 Tesla) |
- |
500 |
|
- |
6.12(Magnetic induction of External Origin 0.5mT) |
- |
1000 |
|
- |
6.12(Abnormal Magnetic Induction of External Origin 10mT) |
- |
500 |
|
- |
6.12(Operation of Accessories) |
- |
500 |
|
- |
6.10.1(Test of power consumption) |
- |
1500 |
|
- |
6.10.2(Test of influence of supply voltage) |
- |
1500 |
|
- |
6.10.3(Test of influence of short time over currents) |
- |
1500 |
|
- |
6.10.4(Test of influence of self-heating) |
- |
2000 |
|
- |
6.10.5(Test of influence of heating) |
- |
2000 |
|
- |
6.10.7(Test of immunity to earth/phase fault) |
- |
2000 |
|
- |
6.11(Electromagnetic Compatibility) |
- |
5000 |
|
- |
6.11(Radio interference measurement) |
- |
20000 |
|
- |
6.11(Fast transient burst test) |
- |
20000 |
|
- |
6.11(Test of immunity to electrostatic discharge) |
- |
20000 |
|
- |
6.11(Test of immunity to electromagnetic HF field) |
- |
25000 |
|
- |
6.11(Surge Immunity test) |
- |
10000 |
|
- |
9.3(Test of Display) |
- |
1000 |
|
- |
6.9(Climatic Codition) |
- |
1000 |
|
- |
6.9(Dry heat test) |
- |
4000 |
|
- |
6.9(Cold test) |
- |
3000 |
|
- |
6.9(Damp heat cyclic test) |
- |
4000 |
|
- |
6.5(Mechanical Requirement) |
- |
2000 |
|
- |
6.5(Vibration test) |
- |
5000 |
|
- |
6.5(Shock test) |
- |
2000 |
|
- |
6.5(Spring hammer test) |
- |
1000 |
|
- |
6.5(Test of protection against penetration of dust and water) |
- |
2500 |
|
- |
6.1(Electrical Requirments) |
- |
500 |
|
- |
6.1(Electrical Requirments) |
- |
500 |
|
- |
6.1(Electrical Requirments) |
- |
500 |
|
- |
6.2(General constructional Requirement) |
- |
500 |
|
- |
6.2(General constructional Requirement) |
- |
500 |
|
- |
6.3(Measurement ( 6.6 of IS 14697)) |
- |
500 |
|
- |
6.6(Display of measured values) |
- |
500 |
|
- |
6.3(Clearance and creepage distances) |
- |
1000 |
|
- |
6.7(Output device) |
- |
500 |
|
- |
6.8(Inspection ) |
- |
500 |
|
- |
6.8.1(Additional information) |
- |
1000 |
|
- |
6.8(Marking of meters
Name plate) |
- |
500 |
|
- |
6.8(BIS Standard Mark) |
- |
500 |
|
- |
6.8(Connection diagrams and terminal marking) |
- |
500 |
|
- |
10.0(Smart Meter Functional Requirements) |
- |
500 |
|
- |
7, 9.4(Data Exchange for Electricity Meter Reading, Tariff and Load Control Companion Specification
(The requirement as per IS 15959 : Part 1 & Part 3 shall apply)) |
- |
500 |
|
- |
8, 9.5(Smart Meter Communicability) |
- |
500 |
|
- |
6.2(Communication module) |
- |
500 |
|
- |
6.4(Test of resistance to heat and fire) |
- |
1000 |
|
- |
Note b of Table 1(Access and data read test) |
- |
500 |
|
- |
Note a of Table 1(Accuracy of the meter at pre-defined points) |
- |
500 |
|
- |
6.10.6(Insulation test) |
- |
1000 |
|
- |
6.10.6(ac high voltage test) |
- |
1500 |
|
- |
6.10.6(Impulse voltage test) |
- |
2000 |
|
- |
6.2.2(Insulating encased meter) |
- |
50 |
|
- |
6.2.2(Terminal Cover(s)) |
- |
50 |
|
- |
6.2.1(Heat Deflection Test) |
- |
500 |
|
- |
6.2.1(Terminals, terminal block and protective earth terminal) |
- |
500 |
|
- |
6.2(Window) |
- |
50 |
|
- |
6.2(Meter case) |
- |
50 |
|
- |
6.10.7((9.6 of IS 14697 ) Insulation Rtequirement ) |
- |
1000 |
|
- |
9.3(Measurement) |
- |
500 |
|
- |
6.8(Inspection ( 7 of IS 14697) ) |
- |
50 |
|
- |
6.7(Inspection ( 6.11 of IS 14697)) |
- |
50 |
|
- |
6.6(Inspection ( 6.10 of IS 14697)) |
- |
50 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 28-04-2022. |
8 |
IS 16444 (2015) |
AC static direct connected watthour smart meter class 1 and 2 - Specification |
- |
-
|
212000.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.10.6(Impulse voltage test) |
- |
3000 |
|
- |
6.10.6(ac high voltage test) |
- |
2500 |
|
- |
6.10.6(Insulation resistance test) |
- |
2000 |
|
- |
6.12(Test on limits of error due to variation of the current) |
- |
5000 |
|
- |
6.12(Test of meter constant) |
- |
1000 |
|
- |
6.12(Test of starting condition) |
- |
2000 |
|
- |
6.12(Test of no-load condition) |
- |
1000 |
|
- |
6.12(Test of ambient temperature influence) |
- |
2000 |
|
- |
6.12(Test of repeatability of error ) |
- |
3000 |
|
- |
6.12(Test of influence quantities) |
- |
2000 |
|
- |
6.12(Voltage Variation) |
- |
500 |
|
- |
6.12(Frequency Variation) |
- |
500 |
|
- |
6.12(Waveform 10% of 3rd Harmonics) |
- |
500 |
|
- |
6.12(Reversed Phase Sequence) |
- |
500 |
|
- |
6.12(Voltage Unbalanced) |
- |
500 |
|
- |
6.12(DC & Even Harmonics in the ac current circuit) |
- |
500 |
|
- |
6.12(Continuous Magnetic Induction of External Origin 67 milli Tesla) |
- |
500 |
|
- |
6.12(Continuous Magnetic Induction of External Origin 0.2 Tesla) |
- |
500 |
|
- |
6.12(Magnetic induction of External Origin 0.5mT) |
- |
500 |
|
- |
6.12(Abnormal Magnetic Induction of External Origin 10mT) |
- |
500 |
|
- |
6.12(Operation of Accessories) |
- |
500 |
|
- |
6.10.1(Test of power consumption) |
- |
500 |
|
- |
6.10.1(Test of influence of supply voltage) |
- |
500 |
|
- |
6.10.1(Test of influence of short time over currents) |
- |
500 |
|
- |
6.10.4(Test of influence of self-heating) |
- |
500 |
|
- |
6.10.5(Test of influence of heating) |
- |
500 |
|
- |
6.10.7(Test of influence of immunity to earth fault) |
- |
500 |
|
- |
6.11(Radio interference measurement) |
- |
35000 |
|
- |
6.11(Fast transient burst test) |
- |
20000 |
|
- |
6.11(Test of immunity to electrostatic discharge) |
- |
20000 |
|
- |
6.11(Test of immunity to electromagnetic HF field) |
- |
35000 |
|
- |
6.11(Surge Immunity test) |
- |
15000 |
|
- |
6.9(Dry heat test) |
- |
5000 |
|
- |
6.9(Cold test) |
- |
4000 |
|
- |
6.9(Damp heat cyclic test) |
- |
5000 |
|
- |
6.5(Test of resistance to heat and fire) |
- |
1000 |
|
- |
6.5(Vibration test) |
- |
2000 |
|
- |
6.5(Shock test) |
- |
2000 |
|
- |
6.5(Spring Hammer test) |
- |
3500 |
|
- |
6.5(Protection against penetration of dust and water) |
- |
1000 |
|
- |
12.4 of IS 13779(Testof Resistance to Heat and Fire
) |
- |
1000 |
|
- |
6.2(General constructional Requirement) |
- |
1000 |
|
- |
6.2(General constructional Requirement) |
- |
1000 |
|
- |
6.2.2(Insulating encased meter) |
- |
500 |
|
- |
6.2.2(Terminal Cover(s)) |
- |
500 |
|
- |
6.2.1(Heat Deflection Test) |
- |
500 |
|
- |
6.2.1(Terminals, terminal block and protective earth ter-minal) |
- |
500 |
|
- |
6.2(Communication module
Load switch) |
- |
500 |
|
- |
6.2(Window) |
- |
500 |
|
- |
6.2(Meter case) |
- |
500 |
|
- |
6.2(General and constructional requirements) |
- |
500 |
|
- |
6.3(Measurement) |
- |
500 |
|
- |
6.6(Display of measured values) |
- |
500 |
|
- |
6.7(Output device) |
- |
500 |
|
- |
6.8(BIS Standard Mark) |
- |
500 |
|
- |
6.8(Marking of smart meters
Name plate) |
- |
500 |
|
- |
cl. 7.1 a) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
500 |
|
- |
cl. 7.1 b) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
500 |
|
- |
cl. 7.1 c) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
500 |
|
- |
cl. 7.1 d) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
500 |
|
- |
cl. 7.1 e) of of IS 13779(MARKING OF METERS : Name Plate
) |
- |
500 |
|
- |
cl. 7.1 f) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
500 |
|
- |
cl. 7.1 g) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
500 |
|
- |
cl. 7.1 h) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
500 |
|
- |
cl. 7.1 j) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
500 |
|
- |
cl. 7.1 k) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
500 |
|
- |
cl. 7.1 m) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
500 |
|
- |
cl. 7.1 p) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
500 |
|
- |
cl. 7.1 n) of IS 13779(MARKING OF METERS : Name Plate
) |
- |
500 |
|
- |
7.2, 10.4(Performance Requirements for Load Switching (UC1)) |
- |
500 |
|
- |
7.2, 10.4(Dielectric strength (G-8)) |
- |
500 |
|
- |
7.2, 10.4(Minimum switched current (G-7)) |
- |
500 |
|
- |
7.2, 10.4(Short circuit current carrying capacity (G-6)) |
- |
500 |
|
- |
7.2, 10.4(Fault current making capacity (G-5)) |
- |
500 |
|
- |
7.2, 10.4(Line to load voltage surge withstand (G-4)) |
- |
500 |
|
- |
8.0(Data Exchange for Electricity Meter Reading,
Tariff and Load Control Companion Specification (Verification up to two Port)) |
- |
500 |
|
- |
9, 10.6(Test of Smart Meter Communicability) |
- |
500 |
|
- |
10.3(Test of Display) |
- |
500 |
|
- |
10.3(Inspection) |
- |
500 |
|
- |
10.4(Test for Load Switch) |
- |
5000 |
|
- |
10.5(Test for Data Exchange Protocol) |
- |
500 |
|
- |
10.6.2(Test for Smart meter communicability ) |
- |
500 |
|
- |
11(Smart Meter Functional Requirement) |
- |
100 |
|
- |
cl. 11.1 of IS 13779(Limits of Error Due to Variation of tile Current) |
- |
100 |
|
- |
cl. 11.2 of IS 13779(Limits of Error Due to Other Influence Quantities (Voltage-Variation, Frequency Variation,
Phase-Sequence, Wave Form, Voltage-Unba.ance)) |
- |
100 |
|
- |
cl. 11.3 of IS 13779(Limits of Error Due to Ambien! Temperature
Variation
) |
- |
100 |
|
- |
cl. 11.4 of IS 13779(Starting and Running w'th No-Load) |
- |
100 |
|
- |
cl. 11.5 of IS 13779(Starting Current) |
- |
100 |
|
- |
cl. 11.6 of IS 13779(Meter Constant) |
- |
100 |
|
- |
cl. 12.7.6.3 of IS 13779(ac Voltage test) |
- |
1000 |
|
- |
cl. 12.7.6.4 of IS 13779(Insulation resistance test) |
- |
500 |
|
- |
12.10.1 a) of IS 13779(Testof Accuracy Requirements : General Test Conditions
) |
- |
500 |
|
- |
12.10.1 b) of IS 13779(Testof Accuracy Requirements : General Test Conditions
) |
- |
500 |
|
- |
12.10.1 c) of IS 13779(Testof Accuracy Requirements : General Test Conditions
) |
- |
500 |
|
- |
12.10.1 d) of IS 13779(Testof Accuracy Requirements : General Test Conditions
) |
- |
500 |
|
- |
12.10.1 e) of IS 13779(Testof Accuracy Requirements : General Test Conditions
) |
- |
500 |
|
- |
12.10.1 f) of IS 13779(Testof Accuracy Requirements : General Test Conditions
) |
- |
500 |
|
- |
cl 11.1 of IS 13779(Limits of Error and Interpretation or Test Results) |
- |
500 |
|
- |
12.16 a) of IS 13779(Limits of Error and Interpretation or Test
Results) |
- |
500 |
|
- |
12.16 b) of IS 13779(Limits of Error and Interpretation or Test
Results) |
- |
500 |
|
- |
12.16 c) of IS 13779(Limits of Error and Interpretation or Test
Results) |
- |
500 |
|
- |
12.15 of IS 13779(Test of Meter Constant/Registration) |
- |
500 |
|
- |
12.14 of IS 13779(Test of Starting Conditions) |
- |
500 |
|
- |
12.13 of IS 13779(Test of No-Load Condition) |
- |
500 |
|
- |
12.12 of IS 13779(Test ofAmbient Temperature Influence) |
- |
500 |
|
- |
12.17 of IS 13779(Repeatability of Error Test
) |
- |
500 |
|
- |
12.11 of IS 13779(Test of Iniluence Quantities) |
- |
500 |
|
- |
12.7.1 of IS 13779(Test of Power Consumption) |
- |
500 |
|
- |
12.7.2 of IS 13779(Test of Influence of Supply Voltage) |
- |
500 |
|
- |
12.7.3 of IS 13779( Test of Influence of Short-time Overcurrents) |
- |
1000 |
|
- |
12.7.4 of IS 13779(Test of Influence of Self-Heating) |
- |
500 |
|
- |
12.7.5 of IS 13779(Test of Influence of Heating) |
- |
500 |
|
- |
12.8 of IS 13779(TestorImmunity to Earth Fault) |
- |
500 |
|
- |
12.9.2 of IS 13779(Test for Immunity to Electrostatic Discharge
(ESD)) |
- |
2000 |
|
- |
12.9.3 of IS 13779(Test for Immunity to EIectromagnetic HF Fields) |
- |
20000 |
|
- |
12.9.4 of IS 13779(FastTransient BurstTest) |
- |
20000 |
|
- |
12.9.5 of IS 13779(Radio Interference Measurement) |
- |
20000 |
|
- |
12.6.1 of IS 13779(Dry Heat Test) |
- |
500 |
|
- |
12.6.2 of IS 13779(Cold Test) |
- |
500 |
|
- |
12.6.3 of IS 13779( Damp Heat Cycle Test) |
- |
1500 |
|
- |
4.4.2.1 of IS 15844(Voltage range) |
- |
500 |
|
- |
4.4.2.2 of IS 15844( Specified operating range
) |
- |
500 |
|
- |
4.4.2.3 of IS 15844(Extended operating range) |
- |
500 |
|
- |
4.4.2.4 of IS 15844( Limit range of operation) |
- |
500 |
|
- |
4.4.2.5 of IS 15844(Withstand range) |
- |
500 |
|
- |
4.4.2.6 of IS 15844(Abnormal voltage conditions) |
- |
500 |
|
- |
4.4.2.7 of IS 15844(Voltage dips and short interruptions) |
- |
500 |
|
- |
4.4.3 of IS 15844(Influence of Short-Time Overcurrents) |
- |
500 |
|
- |
4.4.4 of IS 15844(Influence of Self-Heating) |
- |
500 |
|
- |
4.4.5 of IS 15844(Influence of Heating) |
- |
500 |
|
- |
4.4.6 of IS 15844(Insulation) |
- |
500 |
|
- |
6.3(Clearance and creepage distances) |
- |
500 |
|
- |
11.0(Smart meter functional requirements) |
- |
500 |
|
- |
7.2, 10.4(Electrical endurance (G-3)) |
- |
500 |
|
- |
7.2, 10.4(Normal operation (G-2)) |
- |
500 |
|
- |
Note 1c of Table 1(Remote disconnect/connect) |
- |
500 |
|
- |
Note 1b of Table 1(Access and data read test) |
- |
500 |
|
- |
Note 1a of Table 1(Accuracy of the meter at pre-defined points) |
- |
500 |
|
- |
6.8(Connection diagrams and terminal marking) |
- |
1000 |
|
- |
Table 1 (Note 1)(Schedule of type tests) |
- |
500 |
|
- |
Table 1 (Note 1)(Schedule of type tests) |
- |
600 |
|
- |
6.11(Electromagnetic Compatibility) |
- |
700 |
|
- |
6.8(Inspection) |
- |
600 |
|
- |
6.7(Inspection) |
- |
600 |
|
- |
6.6(Inspection) |
- |
60 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 28-04-2022. |
9 |
IS 15884 (2010) |
Alternating current direct connected static prepayment meters for active energy (Class 1 And 2) - Specification |
- |
-
|
240000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.2(Test of mechanical requirements) |
- |
500 |
|
- |
5.2.1(As per cl 12.3.3 of IS 13779) |
- |
1000 |
|
- |
5.2.2(As per IS 9000 (Part 7/Sec 1)) |
- |
4000 |
|
- |
5.2.3(As per IS 9000 (Part 8)) |
- |
4000 |
|
- |
5.2.4(As per IS 11000 (Part 2 / Sec1)) |
- |
3000 |
|
- |
5.2.5(Protection against penetration of dust (IP5X)) |
- |
500 |
|
- |
5.2.5(Protection against penetration of water (IP1X)) |
- |
500 |
|
- |
5.2.5(500 V dc) |
- |
500 |
|
- |
5.2.5(As per IS 12063) |
- |
500 |
|
- |
5.3(Tests of Climatic Influences) |
- |
500 |
|
- |
5.3.1(according to IS 9000
(Part 3/ Sec 1 to 5)) |
- |
500 |
|
- |
5.3.2(according to IS 9000
(Part 2/Sec 1 to 4)) |
- |
4000 |
|
- |
5.3.3(according to IS 9000 (Part 5/Sec 1 and 2)) |
- |
1500 |
|
- |
5.3.3(As per cl 5.4.6) |
- |
1500 |
|
- |
5.3.3(Visual examination) |
- |
1000 |
|
- |
5.4(As per 5.6.1) |
- |
500 |
|
- |
5.4.1(As per 4.4.1.1) |
- |
1500 |
|
- |
5.4.2(As per 4.4.2.1) |
- |
1500 |
|
- |
5.4.3(Table 8, as per cl4.4.3) |
- |
3000 |
|
- |
5.4.4(Table 9, and cl 4.4.4) |
- |
2000 |
|
- |
5.4.5(As per cl 4.4.5) |
- |
2000 |
|
- |
5.4.6(As per IS 2071 (Part1)) |
- |
500 |
|
- |
5.4.6.2(6 KV, As per cl 12.7.6.2 of IS 13779) |
- |
500 |
|
- |
5.4.6.2(12.7.6.2 of IS 13779) |
- |
2500 |
|
- |
5.4.6.3(Table 15, power source 500 VA) |
- |
2500 |
|
- |
5.4.6.4(500±50V dc) |
- |
2000 |
|
- |
5.5(Test of electromagnetic compatibility) |
- |
5000 |
|
- |
5.5.2(according to IS 14700 (Part 4/Sec 2)) |
- |
10000 |
|
- |
5.5.2(the load switch shall not
operate during the tests.) |
- |
5000 |
|
- |
5.5.3(Table 12 &
IS 14700 (Part 4/Sec 3)) |
- |
35000 |
|
- |
5.5.4(according to IS 14700
(Part 4/Sec 4)) |
- |
20000 |
|
- |
5.5.5(according to IEC 62052-11) |
- |
35000 |
|
- |
5.5.6(Surge Immunity Test) |
- |
10000 |
|
- |
5.5.6(according to IEC 61000-
4-5) |
- |
10000 |
|
- |
5.6(As per cl 4.6) |
- |
5000 |
|
- |
4.6.1(As per table 10 & 11, cl 5.6.1) |
- |
12000 |
|
- |
5.6.3(I= open circuit
V= 115% of rated voltage
test period 60 000/k minutes) |
- |
1000 |
|
- |
5.6.4(As per cl 4.6.3, Table 13) |
- |
1000 |
|
- |
5.6.5(As per cl 4.6.5) |
- |
2000 |
|
- |
5.6.7(Test shall be carried out at 0.05Ib and Ib at UPF load under reference conditions. Twenty error samples shall be taken at time-intervals of 30 minutes) |
- |
3000 |
|
- |
5.8(Test of Load Switch) |
- |
15000 |
|
- |
5.9(Test of Consumption-Based charging function) |
- |
5000 |
|
- |
5.10(Test of Time-Based charging function) |
- |
5000 |
|
- |
6(Functional Requirements) |
- |
500 |
|
- |
Annexure A(Functional Performance) |
- |
500 |
|
- |
4(General Requirements) |
- |
500 |
|
- |
4.1.1(By Inspection) |
- |
500 |
|
- |
4.1.2(By Inspection) |
- |
500 |
|
- |
4.1.3(By Inspection) |
- |
500 |
|
- |
4.1.4(By Inspection) |
- |
500 |
|
- |
4.2(Mechanical Requirements) |
- |
500 |
|
- |
4.2.1(By Inspection) |
- |
500 |
|
- |
4.2.2(By Inspection) |
- |
500 |
|
- |
4.2.2(By Inspection) |
- |
500 |
|
- |
4.2.3(By Inspection) |
- |
500 |
|
- |
4.2.4(IS 13360 (Part 6/Sec 17) for a temperature of 135°C and a pressure of 1.8 MPa (Method A).) |
- |
500 |
|
- |
4.2.4(By inserting copper conductor of appropriate size) |
- |
500 |
|
- |
4.2.4(By Inspection) |
- |
500 |
|
- |
4.2.5(shall have a separate cover which can be sealed independently of the meter cover. The terminal cover shall enclose the actual terminals) |
- |
200 |
|
- |
4.2.5(The terminals their fixing screws, a suitable length of external insulated conductor and its insulation shall be enclosed by a cover with a provision for sealing. ) |
- |
200 |
|
- |
4.2.5(The fixing screws used on the terminal cover for fixing and sealing shall be held captive in the terminal cover.) |
- |
200 |
|
- |
4.2.5(When the meter is mounted on the meter board, no access to the terminals shall be possible without breaking the seal of the terminal cover.) |
- |
200 |
|
- |
4.2.6(By measurement) |
- |
1000 |
|
- |
4.2.7(Standard test fingure) |
- |
1000 |
|
- |
4.2.10(Display of measured values) |
- |
500 |
|
- |
4.2.10.1(By inspection) |
- |
500 |
|
- |
4.2.10.2(By inspection) |
- |
500 |
|
- |
4.2.10.3(By measurement) |
- |
500 |
|
- |
4.2.10.4(By inspection) |
- |
500 |
|
- |
4.2.10.5(By inspection) |
- |
500 |
|
- |
4.2.10.6(By inspection) |
- |
500 |
|
- |
4.2.10.7(By inspection) |
- |
500 |
|
- |
4.2.10.8(Fig. 4, annexure F) |
- |
500 |
|
- |
4.2.10.9(Fig. 5, annexure F) |
- |
500 |
|
- |
4.2.11(By inspection) |
- |
500 |
|
- |
4.2.11.1(By inspection) |
- |
500 |
|
- |
4.2.12(Test on Token Carrier Interface) |
- |
500 |
|
- |
4.6.3(Limits of error due to Ambient temperature Variation) |
- |
500 |
|
- |
4.6.6.2.2(Performance requirement for load switching Utilization category UC2
(Annex G.)) |
- |
1500 |
|
- |
4.6.6.2.2 & G2(Normal operation) |
- |
2000 |
|
- |
4.6.6.2.2 & G3(Electrical endurance) |
- |
2000 |
|
- |
4.6.6.2.2 & G4(Line to load voltage surge withstand) |
- |
1500 |
|
- |
4.6.6.2.2 & G5(Fault current making capacity) |
- |
1500 |
|
- |
4.6.6.2.2 & G6(Short circuit current carrying capacity) |
- |
2000 |
|
- |
4.6.6.2.2 & G7(Minimum switched current) |
- |
2000 |
|
- |
4.6.6.2.2 & G8(Dielectric strength) |
- |
1500 |
|
- |
3.12.6, 4.6.6.2.1 & 5.1.7(Load Switching Capability (UC1)) |
- |
1500 |
|
- |
4.2.10.8(General requirements-
Mechanical and electrical characteristics) |
- |
1000 |
|
- |
4.2.10.9(General requirements-
Optical characteristics) |
- |
1000 |
|
- |
4.2.12.3(Keypad Interface) |
- |
50 |
|
- |
4.6.6.2 , annexure G -8(Performance requirements for Prepayment Meters with Load switching utilization category UC2 and UC3) |
- |
1500 |
|
- |
4.6.6.2 , annexure G -7(Performance requirements for Prepayment Meters with Load switching utilization category UC2 and UC3) |
- |
1500 |
|
- |
4.6.6.2 , annexure G -6(Performance requirements for Prepayment Meters with Load switching utilization category UC2 and UC3) |
- |
1500 |
|
- |
4.6.6.2 , annexure G -5(Performance requirements for Prepayment Meters with Load switching utilization category UC2 and UC3) |
- |
1500 |
|
- |
4.6.6.2 , annexure G -4(Performance requirements for Prepayment Meters with Load switching utilization category UC2 and UC3) |
- |
1500 |
|
- |
4.6.6.2 , annexure G -3(Performance requirements for Prepayment Meters with Load switching utilization category UC2 and UC3) |
- |
2000 |
|
- |
4.6.6.2 , annexure G -2(Performance requirements for Prepayment Meters with Load switching utilization category UC2 and UC3) |
- |
2000 |
|
- |
4.6.6.2 .1(Load switching capability) |
- |
2000 |
|
- |
4.6.6.1 , annexure D - 4.3(Test of crystal Controlled Clocks in Payment Meters) |
- |
2000 |
|
- |
4.6.6.1 , annexure D - 4.2(Test of crystal Controlled Clocks in Payment Meters) |
- |
2000 |
|
- |
4.6.6.1 , annexure D - 4.1(Test of crystal Controlled Clocks in Payment Meters) |
- |
1500 |
|
- |
4.6.6.1 , annexure D - 3.2.3(Test of crystal Controlled Clocks in Payment Meters) |
- |
1500 |
|
- |
4.6.6.1 ,annexure D - 3.2.2(Test of crystal Controlled Clocks in Payment Meters) |
- |
1500 |
|
- |
4.6.6.1 ,annexure D - 3.2.1(Test of crystal Controlled Clocks in Payment Meters) |
- |
1500 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 28-04-2022. |
10 |
IS 14494 (2019) |
Elastomer insulated flexible cables for use in mines - Specification (First Revision) |
- |
-
|
200000 View breakup
For BIS Samples: 1.5 times of BIS Testing Charges and other for 1.1kV- Rs.55,000/- 3.3kV- Rs.70,000/- 3.8/6.6kV- Rs.75,000.00/- 6.35/11kV- Rs.2,00,000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Table 33(a)(Annealing test) |
- |
2000 |
|
For 1.1 kV - 55000.00/-
3.3 kV - 70000.00/-
3.8/6.6 kV – 75000.00/-
6.35/11 kV – 200000/- |
Table 33(a)(Conductor resistance test) |
- |
2500 |
|
- |
5(INSULATION) |
- |
500 |
|
- |
7.1(TAPE : Proofed Tape) |
- |
500 |
|
- |
7.2(TAPE : Polyethylene Terephalate (PETP) or
Polypropylene Base Tape) |
- |
500 |
|
- |
7.3(TAPE ) |
- |
500 |
|
- |
8(CENTRE) |
- |
500 |
|
- |
9.1(FILLERS) |
- |
500 |
|
- |
9.2(FILLERS) |
- |
500 |
|
- |
11.1(ARMOUR) |
- |
500 |
|
- |
11.2(ARMOUR) |
- |
500 |
|
- |
11.2 a)(ARMOURING: Tensile Strength) |
- |
500 |
|
- |
11.2 b)(ARMOURING: Elongation ) |
- |
500 |
|
- |
11.2 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
1250 |
|
- |
11.2 d)(ARMOURING: Uniformity of zinc coating) |
- |
2250 |
|
- |
11.2 e)(ARMOURING: Mass of zinc coating ) |
- |
2250 |
|
- |
12.1(SHEATH : Inner Sheath) |
- |
500 |
|
- |
12.2(SHEATH : Outer Sheath) |
- |
500 |
|
- |
17.1(INSULATION SCREEN) |
- |
500 |
|
- |
17.2(INSULATION SCREEN) |
- |
500 |
|
- |
17.3(INSULATION SCREEN) |
- |
500 |
|
- |
17.4(INSULATION SCREEN) |
- |
500 |
|
- |
18(PROTECTIVE SCREEN) |
- |
500 |
|
- |
27.8(Flammability Test) |
- |
1500 |
|
- |
13.1(REINFORCEMENT MATERIAL : Tape) |
- |
1000 |
|
- |
Table 33(d)(Hot set on Insulation) |
- |
3500 |
|
- |
Table 33(f)(Insulation resistance) |
- |
3500 |
|
- |
Table 33(h), Cl. No. 27.2(Partial discharge test) |
- |
30000 |
|
- |
21.1(LAYING UP OF CORES) |
- |
500 |
|
- |
21.2(LAYING UP OF CORES) |
- |
500 |
|
- |
21.3(LAYING UP OF CORES) |
- |
500 |
|
- |
21.4(LAYING UP OF CORES) |
- |
500 |
|
- |
23.1(ARMOURING) |
- |
500 |
|
- |
23.2(ARMOURING) |
- |
500 |
|
- |
23.3(ARMOURING) |
- |
500 |
|
- |
23.4(ARMOURING) |
- |
500 |
|
- |
Table 33(d)(Elongation at break on Insulation) |
- |
2500 |
|
- |
Table 33(e)(Elongation at break on Sheath) |
- |
2500 |
|
- |
13.2(REINFORCEMENT MATERIAL : Cord/Yarns) |
- |
500 |
|
- |
Table 33(e)(Oil resistance - Elongation on sheath) |
- |
4000 |
|
- |
Table 33(e)(Oil resistance - Tensile strength on sheath) |
- |
4000 |
|
- |
Table 33(e)(Tear resistance on sheath) |
- |
4000 |
|
- |
Table 33(d)(Ozone resistance on Insulation) |
- |
15000 |
|
- |
5.2(Pilot and Earth Cores) |
- |
500 |
|
- |
10(CRADLE SEPARATOR) |
- |
500 |
|
- |
16.1(INSULATION) |
- |
500 |
|
- |
16.2(INSULATION : Thickness of Insulation) |
- |
2500 |
|
- |
16.3(INSULATION : Tolerance on Insulation Thickness) |
- |
2500 |
|
- |
16.4(INSULATION : Application of Insulation) |
- |
500 |
|
- |
16.5(INSULATION) |
- |
500 |
|
- |
28(IDENTIFICATION) |
- |
500 |
|
- |
29.1(PACKING AND MARKING) |
- |
750 |
|
- |
29.2(PACKING AND MARKING) |
- |
750 |
|
- |
14.1(CONSTRUCTION : CONDUCTOR) |
- |
500 |
|
- |
14.2(CONSTRUCTION : CONDUCTOR) |
- |
500 |
|
- |
14.3(CONSTRUCTION : CONDUCTOR) |
- |
500 |
|
- |
14.4(CONSTRUCTION : CONDUCTOR) |
- |
500 |
|
- |
Table 33(j), Cl. No. 27.4(Dielectric Power Factor (as a function of Voltage)) |
- |
30000 |
|
- |
Table 33(n), Cl. No. 27.7(High Voltage test for 4 hrs.) |
- |
15000 |
|
- |
Table 33®, Annex E(Electric tset on semi-conducting screen) |
- |
12000 |
|
- |
27.2(Bending test followed by partial discharge test;) |
- |
12000 |
|
- |
27.4(Dielectric power factor test) |
- |
30000 |
|
- |
27.5(Heating cycle test followed by partial discharge test;) |
- |
25000 |
|
- |
27.6(Impulse voltage test; and) |
- |
1250 |
|
- |
4(CONDUCTOR) |
- |
500 |
|
- |
5.1(Power Cores) |
- |
500 |
|
- |
6(SEMI-CONDUCTING COMPOUND) |
- |
500 |
|
- |
15(CONDUCTOR SCREENING) |
- |
500 |
|
- |
19.1(Individual Core Screen) |
- |
500 |
|
- |
19.2(Collective Screen) |
- |
500 |
|
- |
20.1(CORE IDENTIFICATION) |
- |
500 |
|
- |
20.2(Colour Scheme for Identification) |
- |
500 |
|
- |
20.3(Scheme for Identification by Numbering) |
- |
500 |
|
- |
22.1(INNER SHEATH) |
- |
500 |
|
- |
22.2(Thickness of Inner Sheath) |
- |
2500 |
|
- |
22.3(INNER SHEATH) |
- |
500 |
|
- |
24.1(OUTER SHEATH) |
- |
500 |
|
- |
24.2(Thickness of Outer Sheath) |
- |
2500 |
|
- |
24.3(Tolerance on Thickness of Outer Sheath) |
- |
2500 |
|
- |
24.4(OUTER SHEATH) |
- |
500 |
|
- |
25.1(CABLE CONSTRUCTION AND DIMENSIONS) |
- |
1500 |
|
- |
27.9(Water Absorption Test) |
- |
5000 |
|
- |
30(BIS CERTIFICATION MARKING) |
- |
500 |
|
- |
Table 33(e)(Permanent set on Sheath) |
- |
500 |
|
- |
Table 33(e)(Hot set on Sheath) |
- |
3500 |
|
- |
Table 33(e)(Ageing in air bomb - Elongation on Sheath) |
- |
4500 |
|
- |
Table 33(e)(Ageing in air bomb - Tensile strength on Sheath) |
- |
4500 |
|
- |
Table 33(e)(Tensile strength on Sheath) |
- |
2500 |
|
- |
Table 33(d)(Permanent set on Insulation) |
- |
500 |
|
- |
Table 33(d)(Ageing in air bomb - Elongation on Insulation) |
- |
4500 |
|
- |
Table 33(d)(Ageing in air bomb - Tensile strength on Insulation) |
- |
4500 |
|
- |
Table 33(d)(Ageing in air oven - Elongation on Insulation) |
- |
4000 |
|
- |
Table 33(d)(Ageing in air oven - Tensile strength on Insulation) |
- |
4000 |
|
- |
Table 33(d)(Tensile strength on Insulation) |
- |
2500 |
|
- |
Table 33(c)(Resistivity of steel wire) |
- |
500 |
|
- |
Table 33(b)(Diameter of armour wire) |
- |
500 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 28-04-2022. |
11 |
IS 14220 (2018) |
Openwell submersible pumpsets - Specification (First Revision) |
- |
-
|
20000 View breakup
For BIS Samples: 1.5 times of BIS Testing Charges and other upto 15 Kw Rs.15,000/- Each Additional Kw Rs.1,000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1(Design Features) |
- |
100 |
|
Upto 15 kW : 15000 Rs
16 to 20 kW - 20000 Rs |
8.1.1(Design Features) |
- |
100 |
|
- |
8.1.4(Design Features) |
- |
100 |
|
- |
8.1.5(Design Features) |
- |
100 |
|
- |
8.1.5(Design Features) |
- |
100 |
|
- |
8.1.7(Design Features) |
- |
100 |
|
- |
9(Efficiency) |
- |
500 |
|
- |
10(Performance
(Cl 17.1 of IS 5120)) |
- |
100 |
|
- |
10(Suction and Delivery Ends
(Cl 17.2 of IS 5120)) |
- |
100 |
|
- |
10(Suction and Delivery Ends
(Cl 17.2.1 of IS 5120)) |
- |
100 |
|
- |
10(Fluid Passages
(Cl 17.3 of IS 5120)) |
- |
100 |
|
- |
10(Draining Plugrs
(Cl 17.4 of IS 5120)) |
- |
100 |
|
- |
10(Lantern Ring
(Cl 17.5 of IS 5120)) |
- |
100 |
|
- |
10(Casing
(Cl 17.6 of IS 5120)) |
- |
100 |
|
- |
10(Impeller
(Cl 17.7 of IS 5120)) |
- |
100 |
|
- |
10(Shaft
(Cl 17.8 of IS 5120)) |
- |
100 |
|
- |
10(Shaft Couplings
(Cl 17.9 of IS 5120)) |
- |
100 |
|
- |
10(Bearings
(Cl 17.10 of IS 5120)) |
- |
100 |
|
- |
10(Bearings
(Cl 17.10.1 of IS 5120)) |
- |
100 |
|
- |
10(Bearings
(Cl 17.10.2 of IS 5120)) |
- |
100 |
|
- |
10( Stuffing Boxes
(Cl 17.11 of IS 5120)) |
- |
100 |
|
- |
10(Base Plates
(Cl 17.12 of IS 5120)) |
- |
100 |
|
- |
10(Prime Mover
(Cl 17.13 of IS 5120)) |
- |
100 |
|
- |
10(Name Plate
(Cl 17.14 of IS 5120)) |
- |
100 |
|
- |
10(Name Plate
(Cl 17.14 of IS 5120)) |
- |
100 |
|
- |
10(Name Plate
(Cl 17.14 of IS 5120)) |
- |
100 |
|
- |
10(Name Plate
(Cl 17.14.1 of IS 5120)) |
- |
100 |
|
- |
10.2(Casing) |
- |
100 |
|
- |
10.3(Impeller) |
- |
100 |
|
- |
10.4.1(Shaft) |
- |
100 |
|
- |
10.4.2(Shaft) |
- |
100 |
|
- |
10.5.1(Balancing) |
- |
100 |
|
- |
10.5.2(Balancing) |
- |
100 |
|
- |
10.5.3(Balancing) |
- |
100 |
|
- |
10.5.4(Balancing) |
- |
100 |
|
- |
10.6.1( Provision for Earthing) |
- |
100 |
|
- |
10.6.2( Provision for Earthing) |
- |
100 |
|
- |
10.6.3( Provision for Earthing) |
- |
100 |
|
- |
10.6.4( Provision for Earthing) |
- |
100 |
|
- |
10.7.1(Terminal Marking and Direction of Rotation) |
- |
500 |
|
- |
10.7.2(Terminal Marking and Direction of Rotation) |
- |
500 |
|
- |
10.7.3(Terminal Marking and Direction of Rotation) |
- |
500 |
|
- |
15.2(Laboratory Tests
Cl.8 of IS 11346-2002
Rate of flow and head
Cl.8 of IS 11346-2002) |
- |
1200 |
|
- |
15.2(Laboratory Tests
Cl.8 of IS 11346-2002
Efficiency
Cl.8.3 of IS 11346-2002) |
- |
1200 |
|
- |
15.5(Hydrostatic Pressure Test) |
- |
1200 |
|
- |
16.1.1( Guarantee of Performance) |
- |
3000 |
|
- |
16.1.2( Guarantee of Performance) |
- |
3000 |
|
- |
16.1.3( Guarantee of Performance) |
- |
3000 |
|
- |
16.1.4( Guarantee of Performance) |
- |
3000 |
|
- |
16.1.5( Guarantee of Performance) |
- |
3000 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1.3(Marking) |
- |
500 |
|
- |
7(Constructional features) |
- |
100 |
|
- |
7.1(It is recognized that a number of materials of construction are available to meet the needs for pumps handling clear, cold water.) |
- |
100 |
|
- |
7.2(Gaskets, seals and packings used for clear, cold water pumps shall conform to the applicable requirements specified in 5.2 of IS 5120.) |
- |
100 |
|
- |
7.3(The motor shall be provided with a breathing attachment like bellows, diaphragm etc; to compensate the volumetric variation of
water inside the motor due to change in the temperature.) |
- |
100 |
|
- |
7.4(The motor shall be protected from ingress of well water, sand and other foreign matter by means of cable glands, rubber seals etc.) |
- |
100 |
|
- |
7.5(All materials and components for the motor shall be suitable for application in respect of resistance and mechanical performance
to protect it) |
- |
100 |
|
- |
7.6(The rotor of the wet type open well submersible motor and rotor in water filled designed motor shall be provided with suitable coating
from corrosion under water. However if suitable anticorrosion additive is added in the water, no separate protection on
rotors is necessary.) |
- |
100 |
|
- |
8(Design Features) |
- |
100 |
|
- |
8.1.2(The multi-stage pump shaft may be guided through bearings, the bearings may be provided in stage casing, suction housing and
discharge casing, while in case of intermediate bearings, suitable positions may be selected in the overall span.) |
- |
100 |
|
- |
8.1.3(The pump may be equipped with replaceable bearing and wearing ring, wherever provided.) |
- |
100 |
|
- |
8.1.4(The strainer on the suction shall offer the best compromise amongst restraining large solids from entering the pump and containing
the suction losses to the minimum.) |
- |
100 |
|
- |
8.1.5(The pump shall be capable to give discharge without overloading the prime mover within the permissible current at rated voltage
and supply frequency at minimum +5 percent and minimum –15 percent of the guaranteed duty point head up to 30 m.
Above 30 m, the pump shall be capable to give discharge without overloading the prime mover within the permissible current at rated
voltage and supply frequency at minimum +10 percent and minimum –25 percent of the guaranteed duty point head.) |
- |
100 |
|
- |
12(Cable) |
- |
200 |
|
- |
12.1(Flat/Round cables as per IS694 shall be used) |
- |
200 |
|
- |
12.1.2(The size of the conductor shall be adequate and suitable for contineous use under water and in air.
the length of the cable shall be minimum 2 m externallly unless otherwise specified by the customer) |
- |
200 |
|
- |
12.1.3(The size and of the cable should be suitably selected so that the voltage drop between control panel and the mptor terminal does
not exeed three percent of the rated voltage) |
- |
200 |
|
- |
12.1.4(In case a joint is required to be made between the lead cable supplied with the motor and the user’s cable, a detailed procedure to
make water tight joining shall be supplied by the motor manufacturer.) |
- |
200 |
|
- |
12.1.5(If four core cable is used, the fourth core is to be used for earthing.) |
- |
200 |
|
- |
14.10.1(Type test) |
- |
500 |
|
- |
14.10.1(a)(Insulation Resistance test) |
- |
500 |
|
- |
14.10.1(b)(High Voltage test) |
- |
1000 |
|
- |
14.10.1(c)(Measurement of stator resistance) |
- |
750 |
|
- |
14.10.1(d)(No load test at rated voltage) |
- |
1000 |
|
- |
14.10.1(e)(Reduced voltage running up test at no load) |
- |
1000 |
|
- |
14.10.1(f)(Locked rotor) |
- |
750 |
|
- |
14.10.1(g)(Breakaway (starting) torque) |
- |
750 |
|
- |
14.10.1(h)(Leakage current test;) |
- |
750 |
|
- |
14.10.1(j)(Temperature rise test at rated voltage) |
- |
750 |
|
- |
14.10.1(k)(Temperature rise test at reduced voltage) |
- |
750 |
|
- |
16.1(Guarntee of Performance) |
- |
3000 |
|
- |
16.1.1(The pumpset shall be guaranteed for their performance of the nominal volume rate of flow and the nominal head at the guaranteed
duty point. The overall efficiency of the pumpset shall be guaranteed at the declared duty point only.) |
- |
3000 |
|
- |
16.1.2(The guarantee shall be deemed to have been met with, if the measured values of head, volume rate of flow and overall efficiency
are within the indicated in IS 11346 limits) |
- |
3000 |
|
- |
16.1.3(Open well submersible motor shall not get overloaded in the specified operating head range at rated voltage and supply frequency.) |
- |
3000 |
|
- |
16.1.4(The pump shall be tested for the operating head range as per 8.1.5.) |
- |
3000 |
|
- |
16.1.5(The overloading of motor is that condition when maximum current drawn by the motor exceeds the limit of 1.07 times of the rated
motor current) |
- |
3000 |
|
- |
16.1.6(The tolerance shall apply to guaranteed duty point only.) |
- |
3000 |
|
- |
16.1.7(Performance at rated voltage and supply frequency is actual performance of the set. This is better than performance at rated speed,
since in the entire operating head range speed of motor is higher than rated speed, as motor is running in under loaded condition.) |
- |
750 |
|
- |
16.1.8(The manufacturer shall specify the minimum submergence of pump unit at duty point.) |
- |
750 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
18.1(Marking) |
- |
500 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 28-04-2022. |
12 |
IS 13779 (2020) |
ac STATIC WATTHOUR METERS CLASS 1 AND 2-Specefication |
- |
-
|
125000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12.7.6.2(Impulse voltage test) |
- |
1000 |
|
- |
12.7.6.2(Impulse voltage tests for circuits and between the circuits) |
- |
1000 |
|
- |
12.7.6.2(Impulse voltage test of electric circuits relative to earth) |
- |
500 |
|
- |
12.7.6.3(ac high voltage test) |
- |
2000 |
|
- |
12.7.6.4(Insulation resistance test) |
- |
1000 |
|
- |
11.1(Test on limits of error due to variation of current) |
- |
1000 |
|
- |
12.15 & 11.6(Test of meter constant) |
- |
1000 |
|
- |
12.14 & 11.5(Test of starting condition) |
- |
750 |
|
- |
12.13 & 11.4(Test of no-load condition) |
- |
750 |
|
- |
12.12 & 11.3(Test of ambient temperature influence) |
- |
2000 |
|
- |
12.16 & 11.7(Test of repeatability of error) |
- |
1000 |
|
- |
11.2(Test on limits of error due to other influence quantities) |
- |
1500 |
|
- |
12.7.1(Test of power consumption) |
- |
750 |
|
- |
12.7.2(Test of influence of supply voltage) |
- |
750 |
|
- |
12.7.2(Voltage interruptions of Vref=100% Interruption time: 1sec Number of interruptions: 3 Restoring time between interruptions: 50msec.) |
- |
750 |
|
- |
12.7.3(Test of influence of short time over currents) |
- |
1500 |
|
- |
12.7.4(Test of Influence of self heating) |
- |
1000 |
|
- |
12.7.5(Test of influence of heating) |
- |
1000 |
|
- |
12.8(Test of immunity to earth/phase fault) |
- |
1500 |
|
- |
12.9.6(Radio Interference Measurement) |
- |
1000 |
|
- |
12.9.4(Fast transient burst test) |
- |
17000 |
|
- |
12.9.5(Surge Immunity Test) |
- |
22000 |
|
- |
12.9.2(Test of Immunity to electrostatic discharge) |
- |
20000 |
|
- |
12.9.3(Test of Immunity to electromagnetic HF field) |
- |
22000 |
|
- |
12.6.1(Dry heat test) |
- |
2000 |
|
- |
12.6.2(Cold test) |
- |
3000 |
|
- |
12.6.3(Damp heat cyclic test) |
- |
3500 |
|
- |
12.3.1(Shock test) |
- |
2000 |
|
- |
12.3.2(Vibration test) |
- |
2000 |
|
- |
12.3.3(Spring hammer test) |
- |
1000 |
|
- |
12.5(Test of protection against penetration of dust and water) |
- |
1500 |
|
- |
12.4(Test of resistance to heat and fire) |
- |
2000 |
|
- |
4(Classification) |
- |
500 |
|
- |
5.1(Standard Reference Voltages) |
- |
100 |
|
- |
5.2(Standard Basic Currents) |
- |
100 |
|
- |
5.3(Rated Maximum Current) |
- |
100 |
|
- |
5.4(Standard Frequency) |
- |
100 |
|
- |
6.1(General) |
- |
300 |
|
- |
6.2(Meter Case) |
- |
300 |
|
- |
6.3(Window) |
- |
200 |
|
- |
6.4(Terminals, terminal block and protective earth terminal) |
- |
300 |
|
- |
6.5(Terminals covers and Extended Terminal Cover) |
- |
300 |
|
- |
6.6(Clearance and creepage distances) |
- |
1000 |
|
- |
6.7(Insulating encased meter) |
- |
300 |
|
- |
6.10(Display of measured values) |
- |
500 |
|
- |
6.11(Output device) |
- |
500 |
|
- |
7.1(Name Plate) |
- |
150 |
|
- |
7.2(Connection diagrams and terminal marking) |
- |
150 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 28-04-2022. |
13 |
IS 12615 (2018) |
Line operated three phase AC motors (IE Code) "Efficiency classes and performance specification" (Third Revision) |
- |
-
|
20250 View breakup
For BIS Samples:1.5 times of BIS Testing Charges and other upto 11Kw Rs.20,250/- Each Additional Kw Rs.1,000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.0(Earthing) |
- |
100 |
|
UPTO 10 kW : 15000 RS
11 kW TO 20 kW : 20250 RS |
9.0(Terminal Marking) |
- |
100 |
|
- |
11.0(DUTY AND RATING) |
- |
100 |
|
- |
Cl. 12.2(Pull up test) |
- |
100 |
|
- |
Cl. 15.2(rating) |
- |
750 |
|
- |
15.3.2(Marking) |
- |
750 |
|
- |
16.1.1(Insulation Resistance Test) |
- |
750 |
|
- |
16.1.2(Measurement of Resistance of Windings of Stator) |
- |
750 |
|
- |
16.1.3(No Load Test) |
- |
750 |
|
- |
16.1.4(Locked Rotor Readings of Voltage, Current and Power Input at a Suitable Reduced Voltage) |
- |
750 |
|
- |
16.1.5(5 Reduced Voltage Running up Test at no-load (for squirrel cage motor up to 37 kW only)) |
- |
750 |
|
- |
16.1.6(High Voltage Test) |
- |
750 |
|
- |
16.2.1(Dimensions) |
- |
250 |
|
- |
16.2.2(Locked Rotor Test) |
- |
500 |
|
- |
16.2.2.1(Locked Rotor Test) |
- |
100 |
|
- |
16.2.2.2(Locked Rotor Test) |
- |
100 |
|
- |
16.2.2.2.1(Locked Rotor Test) |
- |
100 |
|
- |
16.2.2.3(Determination of starting characteristics
-locked rotor current) |
- |
100 |
|
- |
16.2.2.3.1(Direct proportion method) |
- |
100 |
|
- |
16.2.3(Full Load Test to Determine Efficiency, Power Factor and Slip) |
- |
1250 |
|
- |
16.2.4(Temperature Rise Test) |
- |
750 |
|
- |
16.2.5(Momentary Overload Test) |
- |
750 |
|
- |
16.3.1( Test for Vibration Severity of Motor) |
- |
500 |
|
- |
16.3.2( Test for Noise Levels of Motor) |
- |
500 |
|
- |
16.3.3( Test for Degree of Protection by Enclosure) |
- |
750 |
|
- |
16.3.4(Over Speed Test) |
- |
500 |
|
- |
16.3.5( Temperature Rise Test at Limiting Values of
Voltage and Frequency Variation) |
- |
500 |
|
- |
18.3(Marking) |
- |
250 |
|
- |
Cl. 18.1(Marking and labelling) |
- |
250 |
|
- |
Cl. 18.2(Marking and labelling) |
- |
250 |
|
- |
Cl. 9(Terminal marking) |
- |
500 |
|
- |
Cl. 16.2.5(Momentary overload test) |
- |
500 |
|
- |
16.1.1(Insulation Resistance Test) |
- |
500 |
|
- |
Cl. 18.3(BIS Certification Marking) |
- |
500 |
|
- |
12.2(Pull up torque) |
- |
100 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 28-04-2022. |
14 |
IS 9968 : Part 1 (1988) |
Specification for elastomer insulatedcables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
-
|
12000 View breakup
Single core Rs.12,000/- additional each extra core Rs.1,500/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21. (a)(Persulphate tests (for copper)) |
- |
500 |
|
- |
21.1( Tensile strength ) |
- |
250 |
|
- |
22.1( Elongation) |
- |
250 |
|
- |
21.1(type test : Ageing In air oven) |
- |
250 |
|
- |
21.1(type test : Ageing in air bomb) |
- |
250 |
|
- |
21.1(type test : Ageing In oxygen
bomb) |
- |
250 |
|
- |
21.1(type test : Hot set elongation) |
- |
250 |
|
- |
21.1(type test : Tear resistance ) |
- |
250 |
|
- |
22.2(type test :Insulauon resistance High voltage (water immersron ) test) |
- |
250 |
|
- |
22.2(type test : Flammability test
( applicable to cables
finished With SE 3 and
SE 4 sheaths only)
) |
- |
250 |
|
- |
21. (b)(Annealing Test (for coper)) |
- |
500 |
|
- |
21. (e)(Conductor Resistance ) |
- |
500 |
|
- |
3.1( Copper Cooduetor) |
- |
250 |
|
- |
3.2(Aluminium conductor) |
- |
250 |
|
- |
4.1(INSULATION : lnsulation for General Service) |
- |
500 |
|
- |
4.2(INSULATION : Heat Resisting insulation) |
- |
500 |
|
- |
4.3(INSULATION : Silicone Rubber Insulation) |
- |
500 |
|
- |
5.1(TAPE : Proofed Tape) |
- |
200 |
|
- |
5.2(TAPE : 2 Polyethyl_ Terephthalate ( PETP ) Tape or
Plastic: Tape or Any Other SlIIitable Tape ) |
- |
200 |
|
- |
5.3(TAPE : Giass Tape) |
- |
200 |
|
- |
6.1(FILLERS : ) |
- |
200 |
|
- |
7.1(BRAID : Textile Braid) |
- |
200 |
|
- |
7.2(BRAID : Glass Braid ) |
- |
100 |
|
- |
8.1(SHEATH : General Service Insulated Cables and Flexible
Cords) |
- |
100 |
|
- |
8.2(SHEATH :Heat Resisting Insulated Cables) |
- |
100 |
|
- |
9.1(PresenRtive Compound) |
- |
100 |
|
- |
9.2(Varnish) |
- |
100 |
|
- |
10( Conductor ) |
- |
500 |
|
- |
11(Separator tape) |
- |
200 |
|
- |
12.2(Insulation : Thickness of Insufatien) |
- |
200 |
|
- |
12.4(Insulation : Allplication of Insulation) |
- |
200 |
|
- |
13(CORE IDENTiFICATlON) |
- |
200 |
|
- |
14(Tape) |
- |
200 |
|
- |
15(BRAIDING) |
- |
200 |
|
- |
16(COMPOUNDING AND VARNISHING) |
- |
100 |
|
- |
17(LAYING UP OF CORES) |
- |
100 |
|
- |
18( Binder tape) |
- |
100 |
|
- |
19.2(Sheath : Thickness of Sheath) |
- |
100 |
|
- |
19.4( Sheath :Colour) |
- |
100 |
|
- |
20( Overall diameter) |
- |
100 |
|
- |
21. (c)( Tensile Test (for aluminium)) |
- |
100 |
|
- |
21. (d)( Wrapping Test (for aluminium)) |
- |
200 |
|
- |
21(Water absorption test) |
- |
500 |
|
- |
23(identification) |
- |
200 |
|
- |
Cl No. 4.1(Ageing in oxygen bomb - Elongation) |
- |
200 |
|
- |
Cl No. 4.1(Ageing in oxygen bomb - Tensile strength ) |
- |
200 |
|
- |
Cl No. 4.1(Ageing in air bomb - Elongation) |
- |
200 |
|
- |
Cl No. 4.1(Ageing in air bomb - Tensile strength ) |
- |
200 |
|
- |
Cl No. 4.1(Ageing in air oven - Elongation) |
- |
200 |
|
- |
Cl No. 4.1(Ageing in air oven - Tensile strength ) |
- |
200 |
|
- |
Cl No. 22.2(High Voltage Test (Water Immersion)) |
- |
200 |
|
- |
Cl No. 4.1(Insulation resistance) |
- |
200 |
|
- |
Cl No. 23.1, 23.2(Identification) |
- |
200 |
|
- |
Cl No. 22.2.2/22.2.3(High Voltage Test / Spark test) |
- |
500 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 28-04-2022. |
15 |
IS 1293 (2019) |
Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) |
- |
-
|
16500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Ratings) |
- |
50.00 |
|
- |
7.1.1(Accessories Classification) |
- |
50.00 |
|
- |
7.1.2(Accessories Classification) |
- |
50.00 |
|
- |
7.1.3(Accessories Classification) |
- |
50.00 |
|
- |
7.1.4(Accessories Classification) |
- |
50.00 |
|
- |
7.1.5(Accessories Classification) |
- |
50.00 |
|
- |
7.2.1(Socket-Outlets Classification) |
- |
50.00 |
|
- |
7.2.2(Socket-Outlets Classification) |
- |
50.00 |
|
- |
7.2.3(Socket-Outlets Classification) |
- |
50.00 |
|
- |
7.2.4(Socket-Outlets Classification) |
- |
50.00 |
|
- |
7.3(Plug Classification) |
- |
50.00 |
|
- |
8.1(MARKING) |
- |
50.00 |
|
- |
8.8(MARKING) |
- |
50.00 |
|
- |
8.9(MARKING) |
- |
50.00 |
|
- |
9.1(CHECKING OF DIMENSIONS) |
- |
100.00 |
|
- |
9.2(CHECKING OF DIMENSIONS) |
- |
100.00 |
|
- |
10.1(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
50.00 |
|
- |
10.3(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
50.00 |
|
- |
10.4(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
50.00 |
|
- |
10.5(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
50.00 |
|
- |
10.6(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
50.00 |
|
- |
10.7(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
50.00 |
|
-- |
11.1(PROVISIONS FOR EARTHING) |
- |
1000 |
|
- |
11.2(PROVISIONS FOR EARTHING) |
- |
1000 |
|
- |
11.3(PROVISIONS FOR EARTHING) |
- |
50.00 |
|
- |
11.4(PROVISIONS FOR EARTHING) |
- |
50.00 |
|
- |
11.5(PROVISIONS FOR EARTHING) |
- |
50.00 |
|
- |
11.6(PROVISIONS FOR EARTHING) |
- |
50.00 |
|
- |
12.1.1(TERMINALS) |
- |
50.00 |
|
- |
12.1.2(TERMINALS) |
- |
50.00 |
|
- |
12.2.1(TERMINALS) |
- |
50.00 |
|
- |
12.2.2(TERMINALS) |
- |
50.00 |
|
- |
12.2.3(TERMINALS) |
- |
50.00 |
|
- |
12.2.4(TERMINALS) |
- |
50.00 |
|
- |
12.2.5(TERMINALS) |
- |
50.00 |
|
- |
12.2.6(TERMINALS) |
- |
100.00 |
|
- |
12.2.7(TERMINALS) |
- |
100.00 |
|
- |
12.2.8(TERMINALS) |
- |
100.00 |
|
- |
12.2.9(TERMINALS) |
- |
100.00 |
|
- |
12.2.10(TERMINALS) |
- |
100.00 |
|
- |
12.2.11(TERMINALS) |
- |
50.00 |
|
- |
12.3.1(TERMINALS) |
- |
50.00 |
|
- |
12.3.2(TERMINALS) |
- |
50.00 |
|
- |
12.3.3(TERMINALS) |
- |
50.00 |
|
- |
12.3.4(TERMINALS) |
- |
50.00 |
|
- |
12.3.5(TERMINALS) |
- |
50.00 |
|
- |
12.3.6(TERMINALS) |
- |
50.00 |
|
- |
12.3.7(TERMINALS) |
- |
50.00 |
|
- |
12.3.8(TERMINALS) |
- |
50.00 |
|
- |
12.3.9(TERMINALS) |
- |
100.00 |
|
- |
12.3.10(TERMINALS) |
- |
200.00 |
|
- |
12.3.11(TERMINALS) |
- |
200.00 |
|
- |
12.3.12(TERMINALS) |
- |
100.00 |
|
- |
13.1(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.2(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.3(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.4(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.5(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.6(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.7(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.8(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.9(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.11(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.12(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.13(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.14(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.15(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.16(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.17(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.18(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.19(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.21(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.22(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.23(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.3(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.4(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.5(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.6(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.7(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.8(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.9(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.11(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.12(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.13(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.14(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.15(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.16(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.17(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.18(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.19(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.21(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.22(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.23(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.23.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.23.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.24(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.25(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.26(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
15(INTERLOCKED SOCKET-OUTLETS) |
- |
200.00 |
|
- |
16.1(RESISTANCE TO AGEING,) |
- |
200.00 |
|
- |
17.1(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
200.00 |
|
- |
17.2(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
200.00 |
|
- |
17.3(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
200.00 |
|
- |
18(OPERATION OF EARTHING CONTACTS) |
- |
100.00 |
|
- |
19(TEMPERATURE RISE) |
- |
200.00 |
|
- |
20(BREAKING CAPACITY) |
- |
100.00 |
|
- |
21(NORMAL OPERATION) |
- |
300.00 |
|
- |
22.1(Verification of the Maximum Withdrawal Force) |
- |
50.00 |
|
- |
22.2(Verification of Minimum Withdrawal Force) |
- |
50.00 |
|
- |
23.1(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
100.00 |
|
- |
23.3(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
100.00 |
|
- |
24.1(MECHANICAL STRENGTH
For all kinds of fixed socket-outlets
) |
- |
100.00 |
|
- |
24.1(MECHANICAL STRENGTH
For portable multiple and combined socket outlets
with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
100.00 |
|
- |
24.1(MECHANICAL STRENGTH
For surface mounting boxes) |
- |
150.00 |
|
- |
24.2(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
150.00 |
|
- |
24.2(MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
150.00 |
|
- |
24.2(MECHANICAL STRENGTH
For plug
1) with enclosures, covers and bodies other than elastomeric or thermoplastic material) |
- |
150.00 |
|
- |
24.2(MECHANICAL STRENGTH
For plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
150.00 |
|
- |
24.3(MECHANICAL STRENGTH
for fixed socket-outlets with a main part intended to be mounted directly on a surface) |
- |
100.00 |
|
- |
24.4(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
100.00 |
|
- |
24.4(MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
100.00 |
|
- |
24.4(MECHANICAL STRENGTH
For Plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
100.00 |
|
- |
24.5(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
100.00 |
|
- |
24.5(MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
100.00 |
|
- |
24.5(MECHANICAL STRENGTH
For Plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
100.00 |
|
- |
24.6(MECHANICAL STRENGTH
For screwed glands of accessories having an IP code higher than IP20) |
- |
100.00 |
|
- |
24.7(MECHANICAL STRENGTH
For plug pins provided with insulating sleeves) |
- |
100.00 |
|
- |
24.8(MECHANICAL STRENGTH
For shuttered socket-outlets) |
- |
100.00 |
|
- |
24.9(MECHANICAL STRENGTH
For portable multiple and combined socket outlets
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
100.00 |
|
- |
24.1(MECHANICAL STRENGTH
For Plug
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
100.00 |
|
- |
24.1(MECHANICAL STRENGTH
For Plug
(1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
100.00 |
|
- |
24.11(MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
50.00 |
|
- |
24.12(MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
50.00 |
|
- |
24.13(MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
150.00 |
|
- |
24.14.1(MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
150.00 |
|
- |
24.14.2(MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
150.00 |
|
- |
24.14.3(MECHANICAL STRENGTH
For plugs and portable socket-outlets) |
- |
150.00 |
|
- |
24.15(MECHANICAL STRENGTH
) |
- |
50.00 |
|
- |
24.16(MECHANICAL STRENGTH
) |
- |
50.00 |
|
- |
24.16(MECHANICAL STRENGTH
For shroud of portable socket-outlets) |
- |
50.00 |
|
- |
25.1(RESISTANCE TO HEAT
Accessories and surface mounting boxes) |
- |
50.00 |
|
- |
25.2(RESISTANCE TO HEAT
Parts of insulating material necessary to retain
current-carrying parts of the earthing circuit in position,
as well as parts of the front surface zone of thermoplastic material) |
- |
100.00 |
|
- |
25.3(RESISTANCE TO HEAT
Parts of insulating material not necessary to retain current-carrying parts and parts of the earthing circuit in position, even though they are in contact with them) |
- |
100.00 |
|
- |
25.4(RESISTANCE TO HEAT
) |
- |
100.00 |
|
- |
26.1(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100.00 |
|
- |
26.2(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100.00 |
|
- |
26.3(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100.00 |
|
- |
26.4(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100.00 |
|
- |
26.5(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100.00 |
|
- |
26.6(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100.00 |
|
- |
26.7(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100.00 |
|
- |
27.1(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
100.00 |
|
- |
27.2(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
50.00 |
|
- |
27.3(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
50.00 |
|
- |
28.1.1(Resistance to Abnormal Heat and to Fire
Glow-Wire Test) |
- |
100.00 |
|
- |
28.1.2(Resistance to Abnormal Heat and to Fire
for plugs with pins provided with insulating sleeves) |
- |
100.00 |
|
- |
28.2(Resistance to Tracking
For accessories other than IP code higher than IPX0 parts of insulating material retaining live parts in position) |
- |
200.00 |
|
- |
29(RESISTANCE TO RUSTING) |
- |
100.00 |
|
- |
30.1(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Pressure Test at High Temperature) |
- |
100.00 |
|
- |
30.2(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Static Damp Heat Test) |
- |
100.00 |
|
- |
30.3(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Tests at Low Temperature) |
- |
100.00 |
|
- |
30.4(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Impact Test at Low Temperature) |
- |
100.00 |
|
- |
13.2(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
16.2(RESISTANCE TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
100.00 |
|
- |
16.3(Resistance to Humidity) |
- |
100.00 |
|
- |
23.4(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
50.00 |
|
- |
8.7(Marking) |
- |
50.00 |
|
- |
8.6(Marking) |
- |
50.00 |
|
- |
8.5(Marking) |
- |
50.00 |
|
- |
8.4(Marking) |
- |
50.00 |
|
- |
8.3(Marking) |
- |
50.00 |
|
- |
8.2(Marking) |
- |
50.00 |
|
- |
10.2(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
50.00 |
|
- |
23.2(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
50.00 |
|
- |
24.17(MECHANICAL STRENGTH) |
- |
50.00 |
|
- |
24.18(MECHANICAL STRENGTH) |
- |
50.00 |
|
- |
24.19(MECHANICAL STRENGTH) |
- |
50.00 |
|
- |
28.1(RESISTANCE OF INSULATING MATERIAL TO ABNORMAL HEAT, TO FIRE AND TO TRACKING) |
- |
50.00 |
|
- |
27(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
100.00 |
|
- |
26(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100.00 |
|
- |
25(RESISTANCE TO HEAT) |
- |
100.00 |
|
- |
24.14(MECHANICAL STRENGTH) |
- |
100.00 |
|
- |
24(MECHANICAL STRENGTH) |
- |
100.00 |
|
- |
23(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
100.00 |
|
- |
22.1.2(FORCE NECESSARY TO WITHDRAW THE PLUG) |
- |
100.00 |
|
- |
22.1.1(FORCE NECESSARY TO WITHDRAW THE PLUG) |
- |
100.00 |
|
- |
19.3(TEMPERATURE RISE) |
- |
100.00 |
|
- |
19.2(TEMPERATURE RISE) |
- |
100.00 |
|
- |
19.1(TEMPERATURE RISE) |
- |
100.00 |
|
- |
17.1.2(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
100.00 |
|
- |
17.1.1(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
100.00 |
|
- |
16.2.2(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
100.00 |
|
- |
16.2.1.2(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
100.00 |
|
- |
16.2.1.1(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
100.00 |
|
- |
16.2.1(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
100.00 |
|
- |
16(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
50.00 |
|
- |
14.10.3(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.10.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.10.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
13.7.3 (CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.7.2 (CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.7.1(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
12.3.11 (b)(TERMINALS) |
- |
100.00 |
|
- |
12.3.11 (a)(TERMINALS) |
- |
100.00 |
|
- |
10.2.2(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
50.00 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 28-04-2022 |
16 |
IS 14697 (2021) |
ac STATIC TRANSFORMER OPERATED WATTHOUR METERS CLASS 02 S AND 05 S AND VAR-HOUR METERS CLASS 02 S 05 S AND 10 S - SPECIFICATION First Revision |
- |
-
|
125000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9.5 & 12.7.6.2(Impulse voltage test) |
- |
2500 |
|
- |
9.5 & 12.7.6.3(a.c. voltage test) |
- |
2000 |
|
- |
12.7.6.4(Insulation resistance test) |
- |
1000 |
|
- |
11.1(Limits of Error Due to Variation of the Current) |
- |
1000 |
|
- |
12.15(Interpretation of Test Results) |
- |
1000 |
|
- |
11.6 & 12.14(Meter Constant) |
- |
1000 |
|
- |
12.13 & 11.5(Starting Current) |
- |
750 |
|
- |
11.4.2 & 12.12(Running with No-Load) |
- |
750 |
|
- |
11.3 & 12.11(Limits of Error Due to Ambient Temperature Variation) |
- |
2000 |
|
- |
11.7 & 12.16(Repeatability of Error Test) |
- |
1500 |
|
- |
9.1 & 12.7.1(Power Consumption) |
- |
750 |
|
- |
9.2.2 & 12.7.2(Influence of Supply Voltage) |
- |
750 |
|
- |
9.2.3 & 12.7.3(Short Time Over Current) |
- |
1500 |
|
- |
9.3 & 12.7.4(Influence of Self-heating) |
- |
1000 |
|
- |
9.4 & 12.7.5(Influence of Heating) |
- |
1000 |
|
- |
"12.8.2("Test for Immunity to Electrostatic Discharge (ESD)
") |
- |
22000 |
|
- |
"12.8.3(Test for Immunity to Electromagnetic HF Fields) |
- |
22000 |
|
- |
"12.8.4(Fast Transient Burst Test) |
- |
17000 |
|
- |
"12.8.5(Surge Immunity Test) |
- |
22000 |
|
- |
"12.8.6(Radio Interference Measurement) |
- |
5000 |
|
- |
12.6.1(Dry heat test) |
- |
2000 |
|
- |
12.6.2(Cold Test) |
- |
3000 |
|
- |
12.6.3(Damp Heat Cycle Test) |
- |
3500 |
|
- |
12.3.1(Shock test) |
- |
2000 |
|
- |
12.3.2(Vibration test) |
- |
2000 |
|
- |
12.3.3(Spring hammer test) |
- |
1000 |
|
- |
12.5(Protection against penetration of dust and water) |
- |
1500 |
|
- |
12.4(Test of resistance to heat and fire) |
- |
2000 |
|
- |
6.1(General) |
- |
300 |
|
- |
6.2(Meter Case) |
- |
300 |
|
- |
6.3(Window) |
- |
200 |
|
- |
6.4(Terminals, Terminals Block(s) and Protective Earth Terminal) |
- |
300 |
|
- |
6.5(Terminal Cover(s)) |
- |
300 |
|
- |
6.10(Display of Measured Values) |
- |
500 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 28-04-2022. |
17 |
IS/IEC 60669 : Part 2 : Sec 1 (2008) |
Switches for Household and Similar Fixed Electrical Installations Part 2 Particular Requirements Section 1 Electronic Switches |
- |
-
|
140000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Classification) |
- |
500 |
|
- |
8(Marking) |
- |
500 |
|
- |
9(Checking
Dimension) |
- |
500 |
|
- |
10(Protection against
Access to Live Parts) |
- |
1500 |
|
- |
11(Provision for
earthing) |
- |
1000 |
|
- |
12(Terminals) |
- |
2000 |
|
- |
13(Constructional
Requirements) |
- |
1000 |
|
- |
14(Mechanism) |
- |
1000 |
|
- |
15(Resistance to
ageing, protection
provided by enclosures of switches, and resistance to humidity ) |
- |
2000 |
|
- |
16(Insulation resistance
& Electric Strength) |
- |
1000 |
|
- |
17(Temperature
Rise) |
- |
1500 |
|
- |
18(Making and
breaking capacity) |
- |
500 |
|
- |
19(Normal
Operation) |
- |
15000 |
|
- |
20(Mechanical
Strength) |
- |
1000 |
|
- |
21(Resistance to
heat) |
- |
1000 |
|
- |
22(Screws, current
-carrying parts and connections) |
- |
1000 |
|
- |
23(Creepage
distances, clearances and distance through sealing compound) |
- |
1000 |
|
- |
24(Resistance of
insulating material to abnormal heat to fire and to tracking) |
- |
2500 |
|
- |
25(Resistance to
rusting) |
- |
1000 |
|
- |
26(EMC
Requirements) |
- |
84000 |
|
- |
101(Abnormal
Conditions) |
- |
2500 |
|
- |
102(Components) |
- |
2500 |
|
- |
CL. 10(Protection against electric shock test) |
- |
1500 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 28-04-2022. |
18 |
IS 8034 (2018) |
Submersible pumpsets - Specification (Third Revision) |
- |
-
|
14100 View breakup
For BIS Samples: 1.5 times of BIS Testing Charges and other upto 15 Kw Rs.15,000/- each additional Kw Rs.1000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1 (a)(Constructional Features) |
- |
150 |
|
- |
6.1 (b)(Constructional Features) |
- |
150 |
|
- |
6.1 (c)(Constructional Features) |
- |
100 |
|
- |
6.1 (d)(Constructional Features) |
- |
150 |
|
- |
6.1 (e)(Constructional Features) |
- |
150 |
|
- |
6.1 (f)(Constructional Features) |
- |
150 |
|
- |
6.2 (a)(Material of construction Part Sub Assembly
Shaft Sleeve) |
- |
150 |
|
- |
6.2 (b)(Material of construction Part Sub Assembly
Casing wear ring
(if provided)) |
- |
150 |
|
- |
6.2 (c)(Material of construction Part Sub Assembly
Bush) |
- |
150 |
|
- |
6.2 (d)(Material of construction Part Sub Assembly
Discharge casing
(if provided)) |
- |
150 |
|
- |
6.2 (e)(Material of construction Part Sub Assembly
Impeller) |
- |
150 |
|
- |
6.2 (f)(Material of construction Part Sub Assembly
Pump Bowl/Diffuser) |
- |
150 |
|
- |
6.2 (g)(Material of construction Part Sub Assembly
Pump Shaft) |
- |
150 |
|
- |
6.2 (h)(Material of construction Part Sub Assembly
Suction Casing) |
- |
150 |
|
- |
6.2.2.1(Gaskets, Seals and Packings) |
- |
150 |
|
- |
6.2.2.2(Gaskets, Seals and Packings) |
- |
150 |
|
- |
6.2.3(Gaskets, Seals and Packings) |
- |
150 |
|
- |
6.2.4(Gaskets, Seals and Packings) |
- |
150 |
|
- |
6.2.5(Gaskets, Seals and Packings) |
- |
150 |
|
- |
7.1.1(Design features:
Typical design features 0f components of pump) |
- |
150 |
|
- |
7.1.2(Design features:
Typical design features 0f components of pump) |
- |
150 |
|
- |
7.1.3(Design features:
Typical design features 0f components of pump) |
- |
150 |
|
- |
7.1.4(Design features:
Typical design features 0f components of pump) |
- |
150 |
|
- |
7.1.5(Design features:
Typical design features 0f components of pump) |
- |
150 |
|
- |
7.1.6(Design features:
Typical design features 0f components of pump) |
- |
150 |
|
- |
8.1(General Requirements) |
- |
150 |
|
- |
8.2(Casing) |
- |
150 |
|
- |
8.3(Impeller) |
- |
150 |
|
- |
8.4.1(Shaft) |
- |
150 |
|
- |
8.4.2(Shaft) |
- |
150 |
|
- |
8.5.1(Balancing) |
- |
150 |
|
- |
8.5.2(Balancing) |
- |
150 |
|
- |
8.7.1(Direction of Rotation) |
- |
150 |
|
- |
8.7.2(Direction of Rotation) |
- |
150 |
|
- |
8.8(Terminal Marking) |
- |
150 |
|
- |
8.9.1(Typical Installation) |
- |
200 |
|
- |
8.9.3(Typical Installation) |
- |
200 |
|
- |
8.9.4c(Earthing) |
- |
500 |
|
- |
9.10 (a)(Insulation Resistance test) |
- |
750 |
|
- |
9.10 (b)(High Voltage test) |
- |
750 |
|
- |
9.10 (c)(Measurement of Stator Resistance) |
- |
750 |
|
- |
9.10 (d)(No Load Test at Rated Voltage) |
- |
750 |
|
- |
9.10 (e)(Reduced voltage Running up test) |
- |
150 |
|
- |
9.10 (f) & (g)(Locked Rotor Test) |
- |
150 |
|
- |
9.10 (h)(Leakage current test) |
- |
150 |
|
- |
9.10 (j)(Temperature Rise Test at Rated Voltage) |
- |
150 |
|
- |
9.10 (k)(Temperature rise test at reduced voltage) |
- |
150 |
|
- |
10.3(Hydrostatic Pressure Test) |
- |
500 |
|
- |
11.1.1(Guarantee of Performance) |
- |
300 |
|
- |
11.1.2(Guarantee of Performance) |
- |
150 |
|
- |
11.1.3(Guarantee of Performance) |
- |
150 |
|
- |
11.1.4(Guarantee of Performance) |
- |
150 |
|
- |
11.1.5(Guarantee of Performance) |
- |
150 |
|
- |
14(Marking) |
- |
150 |
|
- |
8.7(Direction of Rotation) |
- |
150 |
|
- |
8.9(Typical installation) |
- |
150 |
|
- |
8.9.4.1(Earthing of the motor shall be done as per IS 9283 in accordance with the relevant provisions of IS 3043.) |
- |
300 |
|
- |
8.9.4.2(In case of PVC pipes used as discharge pipe, a separate non corrosive, low resistance conductor from motor earth terminal to control
panel earth terminal shall be provided for earthing.) |
- |
400 |
|
- |
8.9.4.3(In case non corrosive GI pipes and clamps are used for the purpose of earthing the motor, earthing connection may be made to
the discharge pipe clamp and to the control panel earth terminal) |
- |
200 |
|
- |
8.6(Submersible cable) |
- |
200 |
|
- |
8.6.1(Flat/Round cables as per IS694 shall be used) |
- |
200 |
|
- |
8.6.2(The size of the conductor shall be adequate and suitable for contineous use under water and in air.
the length of the cable shall be minimum 2 m externallly unless otherwise specified by the customer) |
- |
200 |
|
- |
8.6.3(The size and of the cable should be suitably selected so that the voltage drop between control panel and the mptor terminal does not
exeed three percent of the rated voltage) |
- |
300 |
|
- |
8.6.4(In case a joint is required to be made between the lead cable supplied with the motor and the user’s cable, a detailed procedure to
make water tight joining shall be supplied by the motor manufacturer.) |
- |
300 |
|
- |
7.1.10(Voltage & Frequency variation) |
- |
300 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 28-04-2022. |
19 |
IS 8784 (1987) |
Specification for thermocouple compensating cables (Second Revision) |
- |
-
|
21750 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(Type of thermocouple) |
- |
100 |
|
- |
4.1(Conductor) |
- |
100 |
|
- |
5(INSULATION AND SHEATH) |
- |
100 |
|
- |
7(SHIELDING) |
- |
100 |
|
- |
8.1(NOISE REDUCTION: Drain Wire) |
- |
100 |
|
- |
8.2(NOISE REDUCTION) |
- |
100 |
|
- |
9.1(DIMENSION : Single Wire) |
- |
100 |
|
- |
9.1.1(DIMENSION : Single Wire (Tolerances)) |
- |
100 |
|
- |
9.1.2(DIMENSION : Single Wire (Ovality)) |
- |
100 |
|
- |
9.2.1(Thickness of Insulation ) |
- |
100 |
|
- |
9.2.2(Thickness of Sheath ) |
- |
100 |
|
- |
9.3(Dimension of cable ) |
- |
100 |
|
- |
10.1(Colour Code ) |
- |
100 |
|
- |
12.1(INFORMATION TO BE SUPPLIED BY THE MANUFACTURER) |
- |
100 |
|
- |
11.1(ENVIRONMENTS FOR USE OF DIFFERENT THERMOCOUPLE
COMPENSATING CABLES) |
- |
100 |
|
- |
13.1(PACKING AND MARKING) |
- |
100 |
|
- |
13.2(PACKING AND MARKING) |
- |
100 |
|
- |
13.2.1(Standard Mark) |
- |
100 |
|
- |
14.2(Thermal emf Test ) |
- |
7000 |
|
- |
14.3(Resistance Test) |
- |
1300 |
|
- |
14.4.1( Thickness of Insulation) |
- |
500 |
|
- |
14.4.2.1( Thickness of Sheath : Round ) |
- |
500 |
|
- |
14.4.2.2( Thickness of Sheath : Oval ) |
- |
200 |
|
- |
14.5(Insulation Resistance Test :Volume resistivity ( Before High Voltage test )) |
- |
1000 |
|
- |
15.5(Insulation Resistance Test :Insulation resistance constant ( Before High Voltage test )) |
- |
500 |
|
- |
14.5(Insulation Resistance Test: Volume resistivity ( After High Voltage test )) |
- |
1000 |
|
- |
14.6(Drain Wire Continuity Test ) |
- |
500 |
|
- |
14.7(H.V. Test ) |
- |
2000 |
|
- |
14.8(Heat Shock Test) |
- |
1000 |
|
- |
6(ARMOURING) |
- |
6000 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 28-04-2022. |
20 |
IS 5950 (1984) |
Specification for shot firing cables (For Use Other Than In Shafts) (First Revision) |
- |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
11.1(Manufacturer’s Identification) |
- |
100 |
|
- |
11.2(Cable Code) |
- |
100 |
|
- |
3.1(Conductor : Material -IS : 8130-2013) |
- |
200 |
|
- |
4.1(Insulation : Material -IS : 5831-1984) |
- |
200 |
|
- |
7.1(Insulation : Application ) |
- |
200 |
|
- |
7.2(Thickness of Insulation - average ) |
- |
50 |
|
- |
7.2(Thickness of Insulation - Min. ) |
- |
50 |
|
- |
7.3(Colour of Insulation) |
- |
50 |
|
- |
5.1(Sheath : materail IS : 5831-1984) |
- |
50 |
|
- |
8.1, 9.1 (c)(Nominal radial thickness of sheath) |
- |
50 |
|
- |
8.2(Thickness of Sheath) |
- |
50 |
|
- |
8.2(Thickness of Sheath - min.) |
- |
50 |
|
- |
8.3(Colour of Sheath) |
- |
50 |
|
- |
9.1 a)(Annealing test) |
- |
750 |
|
- |
9.1 b)(Conductor resistance test) |
- |
750 |
|
- |
9.1 d) i)(Insulation : Tensile strength) |
- |
250 |
|
- |
9.1 d) i)(Insulation : elongation at break) |
- |
750 |
|
- |
9.1 d) i)(Sheath : Tensile strength) |
- |
500 |
|
- |
9.1 d) ii)(Ageing in air oven - Insulation : Tensile strength) |
- |
250 |
|
- |
9.1 d) ii)(Ageing in air oven - Insulation : Tensile strength Variation) |
- |
250 |
|
- |
9.1 d) ii)(Ageing in air oven - Insulation : elongation at break) |
- |
250 |
|
- |
9.1 d) ii)(Ageing in air oven - Insulation : elongation variation at break) |
- |
250 |
|
- |
9.1 d) ii)(Ageing in air oven - Sheath : Tensile strength) |
- |
250 |
|
- |
9.1 d) ii)(Ageing in air oven - Sheath : Tensile strength variation ) |
- |
500 |
|
- |
9.1 d) ii)(Ageing in air oven - Sheath : elongation at break) |
- |
500 |
|
- |
9.1 d) ii)(Ageing in air oven - Sheath : elongation variation at break) |
- |
250 |
|
- |
9.1 d) iii )(Loss of mass test - insulation ) |
- |
500 |
|
- |
9.1 d) iii )(Loss of mass test - Sheath ) |
- |
500 |
|
- |
9.1 d) iv )(Hot deformation - insulation ) |
- |
500 |
|
- |
9.1 d) iv )(Hot deformation - sheath ) |
- |
500 |
|
- |
9.1 d) v )(Heat shock - insulation ) |
- |
250 |
|
- |
9.1 d) v )(Heat shock - Sheath ) |
- |
250 |
|
- |
9.1 d) vi )(Shrinkage - insulation ) |
- |
100 |
|
- |
9.1 d) vi )(Shrinkage : Crack observed - insulation ) |
- |
100 |
|
- |
9.1 d) vi )(Shrinkage - Sheath ) |
- |
150 |
|
- |
9.1 d) vi )(Shrinkage: Crack observed - Sheath ) |
- |
100 |
|
- |
10.2(Voltage test ) |
- |
700 |
|
- |
9.1 f)(Insulation resistance test: Volume resistivity ) |
- |
500 |
|
- |
9.1 f)(Insulation resistance test : IR constant) |
- |
500 |
|
- |
10.4(Flammability Test ) |
- |
450 |
|
- |
12.1(packing ) |
- |
50 |
|
- |
12.2(Marking ) |
- |
50 |
|
- |
12.2.1(Standard marks ) |
- |
50 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 28-04-2022. |
21 |
IS 1293 (2005) |
Plugs and socket- outlets of rated voltage up to and including 250 volts and rated current up to 16 amperes |
- |
-
|
15000 View breakup
For BIS Sample: 1.5 times of BIS testing charges, for others: Rs.10,000/- upto 10A, Rs.15,000/- above 10A
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(RATINGS) |
- |
25.00 |
|
- |
6.1(RATINGS) |
- |
25.00 |
|
- |
6.2(RATINGS) |
- |
25.00 |
|
- |
7(CLASSIFICATION) |
- |
25.00 |
|
- |
7.1(CLASSIFICATION) |
- |
25.00 |
|
- |
7.1.1 (CLASSIFICATION) |
- |
25.00 |
|
- |
7.1.2(CLASSIFICATION) |
- |
25.00 |
|
- |
7.1.3 (CLASSIFICATION) |
- |
25.00 |
|
- |
7.1.4(CLASSIFICATION) |
- |
25.00 |
|
- |
7.2(CLASSIFICATION) |
- |
25.00 |
|
- |
7.2.1(CLASSIFICATION) |
- |
25.00 |
|
- |
7.2.2 (CLASSIFICATION) |
- |
25.00 |
|
- |
7.2.3(CLASSIFICATION) |
- |
25.00 |
|
- |
7.2.4(CLASSIFICATION) |
- |
25.00 |
|
- |
7.2.5(CLASSIFICATION) |
- |
25.00 |
|
- |
7.3(CLASSIFICATION) |
- |
25.00 |
|
- |
8.1(MARKING) |
- |
50.00 |
|
- |
8.2(MARKING) |
- |
50.00 |
|
- |
8.3(MARKING) |
- |
50.00 |
|
- |
8.4(MARKING) |
- |
50.00 |
|
- |
8.5(MARKING) |
- |
50.00 |
|
- |
8.6(MARKING) |
- |
50.00 |
|
- |
8.7(MARKING) |
- |
50.00 |
|
- |
8.8(MARKING) |
- |
50.00 |
|
- |
9.1(CHECKING OF DIMENSIONS) |
- |
50 |
|
- |
9.2(CHECKING OF DIMENSIONS) |
- |
50 |
|
- |
9.3(CHECKING OF DIMENSIONS) |
- |
50 |
|
- |
10(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
50 |
|
- |
10.2(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
50 |
|
- |
10.2.1(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
50.00 |
|
- |
10.2.2(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
50 |
|
- |
10.3(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
50.00 |
|
- |
10.5(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
50 |
|
- |
10.6(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
50 |
|
- |
10.7(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
50 |
|
- |
11(PROVISION FOR EARTHING) |
- |
100 |
|
- |
11.1(PROVISION FOR EARTHING) |
- |
50.00 |
|
- |
11.2(PROVISION FOR EARTHING) |
- |
50.00 |
|
- |
11.3(PROVISION FOR EARTHING) |
- |
50.00 |
|
- |
11.4(PROVISION FOR EARTHING) |
- |
50.00 |
|
- |
11.5(PROVISION FOR EARTHING) |
- |
50.00 |
|
- |
12(TERMINALS) |
- |
50 |
|
- |
12.1.1(TERMINALS) |
- |
50 |
|
- |
12.1.2(TERMINALS) |
- |
50 |
|
- |
12.2(TERMINALS) |
- |
50 |
|
- |
12.2.1(TERMINALS) |
- |
50 |
|
- |
12.2.2(TERMINALS) |
- |
50 |
|
- |
12.2.3(TERMINALS) |
- |
50 |
|
- |
12.2.4(TERMINALS) |
- |
50 |
|
- |
12.2.5(TERMINALS) |
- |
50 |
|
- |
12.2.6(TERMINALS) |
- |
50 |
|
- |
12.2.7(TERMINALS) |
- |
50 |
|
- |
12.2.8(TERMINALS) |
- |
50 |
|
- |
12.2.9(TERMINALS) |
- |
50 |
|
- |
12.2.10(TERMINALS) |
- |
50 |
|
- |
12.2.11(TERMINALS) |
- |
50 |
|
- |
12.3(TERMINALS) |
- |
50 |
|
- |
12.3.1(TERMINALS) |
- |
50 |
|
- |
12.3.2(TERMINALS) |
- |
50 |
|
- |
12.3.3(TERMINALS) |
- |
50 |
|
- |
12.3.4(TERMINALS) |
- |
50 |
|
- |
12.3.5(TERMINALS) |
- |
50 |
|
- |
12.3.6(TERMINALS) |
- |
50 |
|
- |
12.3.7(TERMINALS) |
- |
50 |
|
- |
12.3.8(TERMINALS) |
- |
50 |
|
- |
12.3.9(TERMINALS) |
- |
50 |
|
- |
12.3.10(TERMINALS) |
- |
50 |
|
- |
12.3.11 (a)(TERMINALS) |
- |
50 |
|
- |
12.3.11 (b)(TERMINALS) |
- |
50 |
|
- |
12.3.12 (TERMINALS) |
- |
50 |
|
- |
13.1(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
13.2(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
13.3(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
13.4(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
13.5(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
13.9(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
13.16(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
13.14(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
13.17(Construction of fixed Socket Outlets) |
- |
50 |
|
- |
14(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
14.3(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
14.4(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
14.5(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
14.6(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
14.7(Construction of Plugs & Portables socket outlet ) |
- |
50 |
|
- |
14.8(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
- |
14.9(Construction of Plugs & Portables socket outlet ) |
- |
50 |
|
- |
15.0(Interlocked socket-outlets) |
- |
300 |
|
- |
16.1(Resistance to Ageing ) |
- |
350.00 |
|
- |
16.2(Resistance to Harmful Ingress of Water) |
- |
150.00 |
|
- |
16.3(Resistance to humidity) |
- |
150.00 |
|
- |
17(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
350.00 |
|
- |
17.1.1(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
350.00 |
|
- |
17.1.2(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
200 |
|
- |
17.3(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
100 |
|
- |
18.0(Operation of Earthing Contacts) |
- |
200.00 |
|
- |
19(TEMPERATURE RISE) |
- |
350.00 |
|
- |
20.0(Making & Breaking Capacity) |
- |
350.00 |
|
- |
21.0(Normal Operation) |
- |
150 |
|
- |
21(NORMAL OPERATION) |
- |
150 |
|
- |
22(FORCE NECESSARY TO WITHDRAW THE PLUG) |
- |
100 |
|
- |
22.1(Verification of Max withdrawal force) |
- |
100 |
|
- |
22.2(Verification of Minimum withdrawal force) |
- |
100 |
|
- |
23(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
100 |
|
- |
23.1(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
100 |
|
- |
23.2(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
100 |
|
- |
23.3(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
100 |
|
- |
23.4(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
100 |
|
- |
24(MECHANICAL STRENGTH) |
- |
100 |
|
- |
24.1(a) Mechanical Strength
) |
- |
100 |
|
- |
24.3(a) For surface type socket outlet) |
- |
100 |
|
- |
24.6(b) For screwed glands of accessories other than ordinary) |
- |
100 |
|
- |
24.8(c) For shuttered socket-outlets ) |
- |
100 |
|
- |
24.14.1(e)Verification of the Non-removal of Covers or Cover-Plates ) |
- |
100 |
|
- |
24.14.2(f)Verification of the Removal of Covers or Cover-Plates ) |
- |
100 |
|
- |
25.1(Resistance to heat) |
- |
200 |
|
- |
25.2(Resistance to heat) |
- |
200 |
|
- |
25.3(Resistance to heat) |
- |
100 |
|
- |
25.4(Resistance to heat) |
- |
100 |
|
- |
26(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
26.1(Screws, current carrying parts and connections) |
- |
100 |
|
- |
26.2(Screws, current carrying parts and connections) |
- |
100 |
|
- |
26.3(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
26.4(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
26.5(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
26.6(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
- |
26.7(Screws, current carrying parts and connections) |
- |
100 |
|
- |
27(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
100 |
|
- |
27.1(Creepage distances, clearances and distances through sealing compound ) |
- |
100 |
|
- |
27.2(Creepage distances, clearances and distances through sealing compound ) |
- |
100 |
|
- |
27.3(Creepage distances, clearances and distances through sealing compound ) |
- |
100 |
|
- |
28.1.2(Addiitional tests for plugs with pins provided with insulating sleeves) |
- |
200 |
|
- |
28.1.1(Glow-Wire Test ) |
- |
200 |
|
- |
28.2(Resistance to Tracking) |
- |
200 |
|
- |
28.1(RESISTANCE OF INSULATING MATERIAL TO ABNORMAL HEAT, TO FIRE AND TO TRACKING) |
- |
100 |
|
- |
29.0(Resistance to Rusting) |
- |
500 |
|
- |
30(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES) |
- |
100 |
|
- |
30.1(Addiitional tests on pins provided with insulating sleeves - Pressure Test at High Temperature) |
- |
100 |
|
- |
30.2(Addiitional tests on pins provided with insulating sleeves - Static Damp Heat Test) |
- |
100 |
|
- |
30.3(Addiitional tests on pins provided with insulating sleeves - Impact Test at Low Temperature) |
- |
100 |
|
- |
30.4(Addiitional tests on pins provided with insulating sleeves - Tests at Low Temperature) |
- |
100 |
|
- |
10.1(Protection against Electric Shock) |
- |
100.00 |
|
- |
10.4(Protection against Electric Shock) |
- |
50.00 |
|
- |
13.7(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.7.1(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.7.2 (CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.7.3 (CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.8(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.11(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.12(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.13(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.15(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.18(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.19(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.2(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.21(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.22(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.23(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
50.00 |
|
- |
13.1(Construction of fixed Socket Outlets) |
- |
50.00 |
|
- |
14.1(Construction of Plugs & Portables socket outlet ) |
- |
50.00 |
|
- |
14.11(Construction of Plugs & Portables socket outlet ) |
- |
50.00 |
|
- |
14.12(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.13(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.14(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.15(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.16(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.17(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.18(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.19(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.21(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.22(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.23(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.23.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.23.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.24(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
14.25(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50.00 |
|
- |
16.2.1(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
50.00 |
|
- |
16.2.2(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
50.00 |
|
- |
16.2.3(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
50.00 |
|
- |
16.2.4(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
50.00 |
|
- |
17.2(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
100.00 |
|
- |
24.2(For Portable single socket outlets/ plugs) |
- |
50.00 |
|
- |
24.4(For Portable socket outlets/ plugs) |
- |
50.00 |
|
- |
24.5(For Portable single socket outlets/ plugs) |
- |
50.00 |
|
- |
24.7(For plug pins provided with insulating sleeves) |
- |
50.00 |
|
- |
24.9(MECHANICAL STRENGTH) |
- |
50.00 |
|
- |
24.1(For plugs) |
- |
50.00 |
|
- |
24.11(For portable socket outlets having means for suspension on a wall) |
- |
50.00 |
|
- |
24.12(For portable socket outlets having means for suspension on a wall) |
- |
50.00 |
|
- |
24.13(MECHANICAL STRENGTH) |
- |
50.00 |
|
- |
24.15(Verification of the Removal of Covers or Cover-Plates ) |
- |
50.00 |
|
- |
24.16(Verification of the Removal of Covers or Cover-Plates ) |
- |
50.00 |
|
- |
24.17(Verification of the Removal of Covers or Cover-Plates ) |
- |
50.00 |
|
- |
24.18(Verification of the Removal of Covers or Cover-Plates ) |
- |
50.00 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 28-04-2022 |
22 |
IS 9997 (1991) |
Aluminium alloy redraw rods for electrical purposes - Specification (First Revision) |
- |
-
|
10000 View breakup
For BIS Samples – 1.5 times the BIS testing charges.
For others : Rs. 10,000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 6.1(Silicon) |
- |
444.44 |
|
- |
Cl 6.1(Magnesium) |
- |
444.44 |
|
- |
Cl 6.1(Iron) |
- |
444.44 |
|
- |
Cl 6.1(Copper) |
- |
444.44 |
|
- |
Cl 6.1(Manganese) |
- |
444.44 |
|
- |
Cl 6.1(Chromium) |
- |
444.44 |
|
- |
Cl 6.1(Zinc) |
- |
444.44 |
|
- |
Cl 6.1(Boron) |
- |
444.44 |
|
- |
Cl 6.1(Aluminium) |
- |
444.44 |
|
- |
Cl.7("Mechanical properties
Tensile Strength
") |
- |
750 |
|
- |
Cl.7(Elongation) |
- |
750 |
|
- |
Cl.8("Electrical Resistivity
Resistivity
") |
- |
1000 |
|
- |
Cl.8(Conductivity) |
- |
1000 |
|
- |
Cl.9(Dimension and permissible variation) |
- |
1500 |
|
- |
Cl.11(Freedom from defects) |
- |
1000 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 10.05.2019 |
23 |
IS 9968 : Part 2 (2002) |
Specification for elastomer - Insulated cables: Part 2 for working voltages from 3.3 kV up to and including 33 kV (First Revision) |
33 KV |
-
|
185000 View breakup
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,85,000/- for single core Rs.2,40,000/- for three core
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 61,500/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(CONDUCTORS: Cables for Fixed Installation) |
- |
20 |
|
Rs. 185000.00 For single core Rs.240000.00 for three core |
4.2(CONDUCTORS:Flexible Cables) |
- |
20 |
|
- |
5(INSULATION) |
- |
20 |
|
- |
6(SEMICONDUCTING COMPOUND) |
- |
20 |
|
- |
7.1(Proofed Tape) |
- |
20 |
|
- |
7.1(Proofed Tape: Thickness) |
- |
20 |
|
- |
7.2(Polyethylene Terephthalate ( P E T P ) or
Polypropylene Base Tape : Thickness) |
- |
20 |
|
- |
7.3(Tape ) |
- |
20 |
|
- |
8(SCREENING) |
- |
20 |
|
- |
9(CENTRE AND FILLERS) |
- |
20 |
|
- |
10(ARMOUR) |
- |
50 |
|
- |
11.1(Inner Sheath) |
- |
20 |
|
- |
11.2(Outer Sheath) |
- |
20 |
|
- |
12.1(Tapes) |
- |
20 |
|
- |
12.2(Cords and Yarns) |
- |
20 |
|
- |
13.1 & 13.2(CONSTRUCTION:CONDUCTORS-Cables for Fixed Installations/Flexible Cables) |
- |
20 |
|
- |
13.3(Earthing Conductor) |
- |
50 |
|
- |
13.3.1(Earthing Conductor) |
- |
30 |
|
- |
13.4(Separator Tape) |
- |
20 |
|
- |
14(CONDUCTOR SCREENING) |
- |
20 |
|
- |
15.1(INSULATION : Application) |
- |
20 |
|
- |
15.2(Thickness of Insulation) |
- |
500 |
|
- |
15.3(Tolerance on Thickness of Insulation) |
- |
500 |
|
- |
16.1(INSULATION SCREENING : Application) |
- |
20 |
|
- |
16.2(INSULATION SCREENING : Parts ) |
- |
20 |
|
- |
16.3(INSULATION SCREENING : Non Metallic Parts ) |
- |
20 |
|
- |
16.4(INSULATION SCREENING : Metallic Parts ) |
- |
20 |
|
- |
17(CORE IDENTIFICATION) |
- |
20 |
|
- |
17(CORE IDENTIFICATION: Unscreed cable ) |
- |
50 |
|
- |
18.1(LAYING UP OF CORES) |
- |
50 |
|
- |
18.2(LAYING UP OF CORES : Flexible cable) |
- |
50 |
|
- |
18.3(LAYING UP OF CORES : Binder Tape) |
- |
50 |
|
- |
19.1(Inner Sheath : Application) |
- |
50 |
|
- |
19.2(Thickness of Inner Sheath) |
- |
500 |
|
- |
19.3(Inner Sheath : proofed tape) |
- |
30 |
|
- |
20.1(ARMOURING: Application) |
- |
30 |
|
- |
20.2(Type of Armour) |
- |
50 |
|
- |
20.2 1.2(Direction of lay of armour) |
- |
20 |
|
- |
20.2 1.3(Joint in armour) |
- |
20 |
|
- |
20.2.2(Filling Factot ) |
- |
20 |
|
- |
20.2.2(Diameter of braiding) |
- |
20 |
|
- |
20.2.2.1(Braiding material) |
- |
20 |
|
- |
20.3(Substitution of the galvanized steel wires/formed) |
- |
20 |
|
- |
21.1(OUTER SHEATH) |
- |
250 |
|
- |
21.2(Coulor of Outer sheath) |
- |
250 |
|
- |
21.3(Thickness of Outer Sheat: Average) |
- |
250 |
|
- |
21.3(Thickness of Outer Sheat: Minimum) |
- |
250 |
|
- |
22.1 a)1)(Annealing test
(for copper) - IS 10810: Part 1) |
- |
1000 |
|
- |
22.1 a)2)(Tensile test
(for aluminium) -IS 10810: Part 2) |
- |
1500 |
|
- |
22.1 a)3)(Wrapping Test
(for aluminium) - IS 10810: Part 3) |
- |
1000 |
|
- |
22.1 a)4)(Conductor resistance
test) |
- |
2500 |
|
- |
22.1 a)5)(Persulphate test
(tinned copper
conductor)- IS 10810: Part 4) |
- |
2500 |
|
- |
22.1 b)1)(Test for Galvanized Steel
Wires/Formed Wires
1) Dimensions -IS 10810: Part 36) |
- |
1500 |
|
- |
22.1 b)2)i)(Test for Galvanized Steel
Wires/Formed Wires
2) Tensile Strentgh -IS 10810: Part 37) |
- |
1250 |
|
- |
22.1 b)2)ii)(Test for Galvanized Steel
Wires/Formed Wires
2) Elongation at break -IS 10810: Part 37) |
- |
1250 |
|
- |
22.1 b)2)iii)(Test for Galvanized Steel
Wires/Formed Wires
3) Torsion (for round
wires only) -IS 10810: Part 38) |
- |
1000 |
|
- |
22.1 b)2)iv)(Test for Galvanized Steel
Wires/Formed Wires
4) Winding (for strips
only) -IS 10810: Part 39) |
- |
1000 |
|
- |
22.1 b)2)v)(Test for Galvanized Steel
Wires/Formed Wires
5) Zinc coating : Uniformity-IS 10810: Part 40) |
- |
500 |
|
- |
22.1 b)2)vi)(Test for Galvanized Steel
Wires/Formed Wires
5) Zinc coating : Mass -IS 10810: Part 41) |
- |
500 |
|
- |
22.1 b)2) vii) (Resistivity - IS 10810: Part 42) |
- |
1000 |
|
- |
22.1 c)2)(Physical Tests for
Insulation : Tensile Strenth - IS 10810: Part 7) |
- |
500 |
|
- |
22.1 c)2)(Physical Tests for
Insulation : Elongation - IS 10810: Part 7) |
- |
500 |
|
- |
22.1 c)2)(Physical Tests for
Sheath : Tensile Strenth - IS 10810: Part 7) |
- |
500 |
|
- |
22.1 c)2)(Physical Tests for
Sheath : Elongation - IS 10810: Part 7) |
- |
500 |
|
- |
22.1 c)3)(Physical Tests for
Insulation ( Ageing in air oven): Tensile Strenth - IS 10810: Part 11) |
- |
800 |
|
- |
22.1 c)3)(Physical Tests for
Insulation ( Ageing in air oven): Tensile Strenth Variation - IS 10810: Part 12) |
- |
800 |
|
- |
22.1 c)3)(Physical Tests for
Insulation( Ageing in air oven) : Elongation - IS 10810: Part 11) |
- |
800 |
|
- |
22.1 c)3)(Physical Tests for
Insulation( Ageing in air oven) : Elongation variation - IS 10810: Part 12) |
- |
800 |
|
- |
22.1 c)3)(Physical Tests for
Sheath( Ageing in air oven) : Tensile Strenth - IS 10810: Part 11) |
- |
800 |
|
- |
22.1 c)3)(Physical Tests for
Sheath( Ageing in air oven) : Tensile Strenth variation - IS 10810: Part 12) |
- |
800 |
|
- |
22.1 c)3)(Physical Tests for
Sheath ( Ageing in air oven): Elongation - IS 10810: Part 11) |
- |
800 |
|
- |
22.1 c)3)(Physical Tests for
Sheath ( Ageing in air oven): Elongation variation - IS 10810: Part 12) |
- |
800 |
|
- |
22.1 c)4)(Physical Tests for
Insulation ( Ageing in air bomb): Tensile Strenth variation - IS 10810: Part 56) |
- |
800 |
|
- |
22.1 c)4)(Physical Tests for
Insulation( Ageing in air bomb) : Elongation variation - IS 10810: Part 56) |
- |
800 |
|
- |
22.1 c)4)(Physical Tests for
Sheath(Ageing in air bomb) : Tensile Strenth variation - IS 10810: Part 56) |
- |
800 |
|
- |
22.1 c)4)(Physical Tests for
Sheath ( Ageing in air bomb): Elongation variation - IS 10810: Part 56) |
- |
800 |
|
- |
22.1 c)5)(Physical Tests for
Insulation :Hot set Elongation - IS 10810: Part 30) |
- |
750 |
|
- |
22.1 c)5)(Physical Tests for
Insulation :Permanent set - IS 10810: Part 30) |
- |
750 |
|
- |
22.1 c)5)(Physical Tests for
Sheath :Hot set Elongation - IS 10810: Part 30) |
- |
750 |
|
- |
22.1 c)5)(Physical Tests for
Sheath :Permanent set - IS 10810: Part 30) |
- |
750 |
|
- |
22.1 c)6)(Physical Tests for
Sheath(Oil resistance test) : Tensile Strenth Variation - IS 10810: Part 31) |
- |
1500 |
|
- |
22.1 c)6)(Physical Tests for
Sheath ( Oil resistance test): Elongation Variation - IS 10810: Part 31) |
- |
1500 |
|
- |
22.1 c)7)(Tear Resistance test - IS 10810: Part 17) |
- |
2000 |
|
- |
22.1 c)8)(Shrinkage : Insulation - IS 10810: Part 12) |
- |
250 |
|
- |
22.1 c)8)(Shrinkage test- Crack observed : Insulation - IS 10810: Part 13) |
- |
250 |
|
- |
22.1 c)8)(Shrinkage test : Sheath - IS 10810: Part 12) |
- |
250 |
|
- |
22.1 c)9)(Hot deformation test : Insulation - IS 10810: Part 15) |
- |
350 |
|
- |
22.1 c)9)(Hot deformation test : Sheath - IS 10810: Part 15) |
- |
350 |
|
- |
22.1 c)10)(Loss of mass in air
oven : Insulation - IS 10810: Part 10) |
- |
1500 |
|
- |
22.1 c)10)(Loss of mass in air
oven : Sheath - IS 10810: Part 10) |
- |
1500 |
|
- |
22.1 c)11)(Heat shock : Insulation - IS 10810: Part 14) |
- |
250 |
|
- |
22.1 c)11)(Heat shock : Sheath - IS 10810: Part 14) |
- |
250 |
|
- |
22.1 c)12)(Thermal stability : Insulation - IS 10810: Part 60) |
- |
350 |
|
- |
22.1 c)12)(Thermal stability : Sheath - IS 10810: Part 60) |
- |
350 |
|
- |
22.1 d)(Insulation Resistance Test: Volume resistivity ) |
- |
500 |
|
- |
22.1 d)(Insulation Resistance Test: Insulation resistance constant ) |
- |
500 |
|
- |
22.1 e)(Partial Discharge Test) |
- |
32000 |
|
- |
22.1 f)(Bending Test Followed by
Partial Discharge Test) |
- |
500 |
|
- |
22.1 g)(Dielectric Power Factor
Test
1) As a function of Voltage) |
- |
16000 |
|
- |
22.1 g)(Dielectric Power Factor
Test
1) As a function of
temperature) |
- |
16000 |
|
- |
22.1 h)(Heating Cycle Test) |
- |
32000 |
|
- |
22.1 j)(Impulse Withstand Test) |
- |
35000 |
|
- |
22.1 k)(High Voltage Test
for Four Hours) |
- |
5000 |
|
- |
22.1 m)(Water Absorption Test - IS 10810: Part 28) |
- |
3000 |
|
- |
22.1 n)(Flammability) |
- |
1000 |
|
- |
24.1(Manufacturer's Identification) |
- |
20 |
|
- |
24.2(Voltage Identification) |
- |
20 |
|
- |
24.3(Cable Code) |
- |
30 |
|
- |
25.2.1(Marking on drum ) |
- |
20 |
|
- |
25.2.2(BIS Certification Marking) |
- |
20 |
|
- |
22.4 (a)(Ozone Resistance Test) |
- |
2000 |
|
- |
22.4 (b)(Cold impacts test for PVC sheath) |
- |
1000 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 10.05.2019
Excluding:
Cl. 22.4a) Ozone Resistance Test ( Optional test) |
24 |
IS 16018 (2012) |
Wheeled fire extinguishers - Performance and construction - Specification |
- |
-
|
133550 View breakup
For BIS Samples – 1.5 times the BIS testing charges. For others :
Rs.40000/- (except fire performance test) Fire Performance test: Rs.12000/- for 1A Class, Rs.15000/- for 2A Class, Rs.16000/- for 3A Class, Rs.25000/- for 4A Class, Rs.30000/- for 6A Class, Rs.33000/- for 10A Class, Rs.47000/- for 15A Class, Rs.68000/- for 20A Class, Rs.4500/- for 8B Class, Rs.6000/- for 13B Class, Rs.9000/- for 21B Class, Rs.12000/- for 34B Class, Rs.32000/- for 55 B Class, Rs.36500/- for 70 B Class, Rs.46000/- for 89 B Class, Rs.51500/- for 113 B Class, Rs.61000/- for 144B Class, Rs.65500/- for 183B Class, Rs.76000/- for 233B Class, - Rs. 18,000/-.for Electrical Conductivity of extinguisher Discharge Rs. 2000/- Fill density and filling tolerances For Extinguisher Media of: IS 14609 ,Rs.14500/- IS 4308, Rs.8500/- IS 4989, Rs.20000/- IS 4989(Part 4), Rs.26500/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 4(Types of Wheeled Fire Extinguishers) |
- |
250 |
|
- |
Cl 5.3(Fill Density) |
- |
500 |
|
- |
Cl 5.4(Filling Tolerance) |
- |
500 |
|
- |
Cl 5.5.1(Nominal Charge) |
- |
500 |
|
- |
Cl 6.1(Operating Temperature) |
- |
500 |
|
- |
Cl 6.2.1(Effective Discharge Time) |
- |
750 |
|
- |
Cl 6.2.2(Bulk Range) |
- |
750 |
|
- |
Cl 6.3(Resistance To Temperature Changes) |
- |
3000 |
|
- |
Cl 6.5(Intermittent Discharge Test) |
- |
1250 |
|
- |
Cl 7.6(Resistance to Corrosion) |
- |
6000 |
|
- |
Cl 7.8(Intermittent Discharge Test) |
- |
0 |
|
- |
Cl 8.1(Rating Sutability for Various Classes of Fire) |
- |
76000 |
|
Rs. 57550/- except fire performance test
fire performance test 12K for 1A
15K=2A
16K=3A
25K=4A
30K=6A
33K=10A
47K=15A
68K=20A
4500=8B
6K =13B
9K=21B
12K=34B
32K=55B
365K=70B
46K=89B
515K =113B
61K=144B
655K=183B
76K=233B Class |
Cl 9.1.1(Pressure Cycling Test) |
- |
0 |
|
- |
Cl 9.2(Low Pressure Extinguishers) |
- |
1000 |
|
- |
Cl 9.2.5(Welded Low Carbon Steel Cylinder) |
- |
1000 |
|
- |
Cl 9.2.6(Stainless Steel Cylinder) |
- |
1000 |
|
- |
Cl 9.2.7(Aluminium Cylinder) |
- |
1000 |
|
- |
Cl 9.3(Carrying Handle) |
- |
500 |
|
- |
Cl 9.5(Caps, Valves and Closures) |
- |
500 |
|
- |
Cl 9.8.6(Test for Exposure to Extinguishing Medium) |
- |
2500 |
|
- |
Cl 9.9(Hose Assemblies) |
- |
500 |
|
- |
Cl 9.11(Safety Locking Devices) |
- |
500 |
|
- |
Cl 9.13(Water Based Extinguishers) |
- |
1000 |
|
- |
Cl 9.12.1(General ) |
- |
500 |
|
- |
Cl 10.1(Colour) |
- |
250 |
|
- |
Clause 8.4.1.1(Sulphur) |
- |
500 |
|
- |
Clause 8.4.1.1(Phosphorus) |
- |
500 |
|
- |
Clause 8.4.1.1(Carbon) |
- |
500 |
|
- |
Clause 8.4.2.2(Carbon) |
- |
500 |
|
- |
Cl 9.1(High Pressure Extinguishers) |
- |
1000 |
|
- |
Cl 9.8.5(Normally Non Pressurized Components) |
- |
500 |
|
- |
6.6.1(External Corrosion Test) |
- |
0 |
|
- |
8.18.1(Carriage Assembly) |
- |
750 |
|
- |
8.7.1(Caps valves and closure) |
- |
500 |
|
- |
8.11.1(Requirement of the Discharge Assemblies) |
- |
1050 |
|
- |
8.15(Safety Locking Devices) |
- |
1000 |
|
- |
8.17(Dip tubes and Filters for water based Extinguisher) |
- |
1000 |
|
- |
Cl no 8.1(16018 :2012) |
- |
1500 |
|
- |
9.1(Colour) |
- |
250 |
|
- |
8.2(High Pressure Cylinder) |
- |
1000 |
|
- |
6.6.2(Internal Corrosion Test) |
- |
2500 |
|
- |
6.7.1(Observation of Durability Test after Nozzle Drop Test and Displaced Test) |
- |
1000 |
|
- |
6.7.2(Durability test of trailer mounted fire extinguisher) |
- |
2000 |
|
- |
8.3.2(Deformation Test) |
- |
1500 |
|
- |
8.6(Minimum wall thickness of the cylinder) |
- |
1000 |
|
- |
6.4(Retention of charge) |
- |
1000 |
|
- |
8.14(Method of operation for gas cartridge type extinguishers) |
- |
1000 |
|
- |
8.14(Method of operation for carbon dioxide extinguishers) |
- |
1000 |
|
- |
Cl no 6.8(16018 :2012) |
- |
18000 |
|
only for Water and foam type fire extinguisher (Electrical Conductivity Test) |
8.13.1(Horn of carbon dioxide extinguisher) |
- |
1000 |
|
- |
8.12(Control valve test) |
- |
1000 |
|
- |
8.8(Safety and Anti-overfill devices) |
- |
750 |
|
- |
8.3.1(Burst Test) |
- |
1000 |
|
- |
8.13.3(Load test on discharge horn) |
- |
1000 |
|
- |
8.9.2(Leakage Test) |
- |
1000 |
|
- |
Cl no 7.1(16018 :2012) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
8.3.3(Pressure cycling Test) |
- |
2500 |
|
- |
Cl no 8.3(16018 :2012) |
- |
250 |
|
- |
7.3(Class B and Class C Fire Tests) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
Cl-7.2 (Amendment -1)(Class A, Class B and Class C Fire Test) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
7.2(Class 'A' Fire Test 1A) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
7.2(Class 'A' Fire Test 2A) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
7.2(Class 'A' Fire Test 3A) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
7.2(Class 'A' Fire Test 4A) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
7.2(Class 'A' Fire Test 6A) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
7.2(Class 'A' Fire Test 10A) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
7.2(Class 'A' Fire Test 15A) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
7.2(Class 'A' Fire Test 20A) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
7.2(Class 'B' Fire Test 8B) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
7.2(Class 'B' Fire Test 13B) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
7.2(Class 'B' Fire Test 21B) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
7.2(Class 'B' Fire Test 34B) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
7.2(Class 'B' Fire Test 55B) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
7.2(Class 'B' Fire Test 70B) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
7.2(Class 'B' Fire Test 89B) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
7.2(Class 'B' Fire Test 113B) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
7.2(Class 'B' Fire Test 144B) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
7.2(Class 'B' Fire Test 183B) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
7.2(Class 'B' Fire Test 233B) |
- |
76000 |
|
performance test 12K for 1A,15K for 2A,16K for 3A ,25K for 4A,30K for 6A,33K for 10A,47K for 15A,68K for20A,4500 for8B,6K for 13B,9K for 21B,12K for 34B,32K for 55B,365K for 70B,46Kfor 89B,515K for 113B,61K for 144B,655K for 183B 76K for 233B CLASS |
8.18.3(Hose Retaining Unit) |
- |
100 |
|
- |
8.18.2(Mobility) |
- |
100 |
|
- |
8.16(Pressure gauges for low pressure extinguishers) |
- |
100 |
|
- |
8.13.2(Requirement to prevent loosening or detachment) |
- |
100 |
|
- |
8.11.3(Requirement of burst pressure of hose assemblies for carbon dioxide fire extinguishers) |
- |
100 |
|
- |
8.11.3(Requirement of burst pressure of hose assemblies for except carbon dioxide fire extinguishers) |
- |
250 |
|
- |
8.11.2(Requirement of hose and coupling system) |
- |
250 |
|
- |
8.7.6(Requirement of edges and surfaces) |
- |
250 |
|
- |
8.7.5(Requirement of burst test of cap,valve and closure) |
- |
250 |
|
- |
8.7.4(Requirement of collar) |
- |
250 |
|
- |
8.7.3(Requirement of filling opening diameter) |
- |
250 |
|
- |
8.7.2(Requirement of threaded connections on cylinder) |
- |
250 |
|
- |
8.1.7(Drain Plug) |
- |
1500 |
|
- |
8.1.6(Thread of Plastic Components) |
- |
1500 |
|
- |
8.1.4(Construction Requirement) |
- |
1500 |
|
- |
8.1.3(Requirement of Welding) |
- |
1500 |
|
- |
8.1.2(Leakage Observation during conditioning Test) |
- |
1500 |
|
- |
5.5.2(Gross Mass) |
- |
250 |
|
- |
6.7.4(Displaced Test) |
- |
250 |
|
- |
6.7.3(Nozzle Drop Test) |
- |
250 |
|
- |
3.16 and 8.1.1(Determination of maximum service pressure) |
- |
250 |
|
- |
3.19 and 8.3(Determination of Service Pressure) |
- |
250 |
|
- |
Cl no 4(16018 :2012) |
- |
250 |
|
- |
Cl no 5.3(16018 :2012) |
- |
500 |
|
- |
Cl no 5.4(16018 :2012) |
- |
500 |
|
- |
Cl no 5.5.1(16018 :2012) |
- |
500 |
|
- |
Cl no 5.5.2(16018 :2012) |
- |
250 |
|
- |
Cl no 6.1(16018 :2012) |
- |
500 |
|
- |
Cl no 6.2.1 & 6.2.1.1(16018 :2012) |
- |
750 |
|
- |
Cl no 6.2.2 & 6.2.2.1(16018 :2012) |
- |
750 |
|
- |
Cl no 6.3 & 6.3.1(16018 :2012) |
- |
4000 |
|
- |
Cl no 6.4(16018 :2012) |
- |
1000 |
|
- |
Cl no 6.5(16018 :2012) |
- |
1250 |
|
- |
Cl no 6.6.1(16018 :2012) |
- |
7500 |
|
- |
Cl no 6.6.2(16018 :2012) |
- |
2500 |
|
- |
Cl no 6.7(16018 :2012) |
- |
250 |
|
- |
Cl no 8.2(16018 :2012) |
- |
1000 |
|
- |
Cl no 8.3.1(16018 :2012 Burst test) |
- |
1000 |
|
- |
Cl no 8.3.2(16018 :2012) |
- |
1500 |
|
- |
Cl no 8.4.1(Welded low carbon steel) |
- |
500 |
|
- |
Cl no 8.4.2.2(16018 :2012) |
- |
500 |
|
- |
Cl no 8.6(16018 :2012) |
- |
1000 |
|
- |
Cl no 8.7(16018 :2012) |
- |
250 |
|
- |
Cl no 8.7.2(16018 :2012) |
- |
250 |
|
- |
Cl no 8.7.4(16018 :2012) |
- |
250 |
|
- |
Cl no 8.7.5(16018 :2012) |
- |
250 |
|
- |
Cl no 8.7.6(16018 :2012) |
- |
250 |
|
- |
Cl no 8.8.1(16018 :2012) |
- |
250 |
|
- |
Cl no 8.8.2(16018 :2012) |
- |
250 |
|
- |
Cl no 8.9.2(16018 :2012) |
- |
1000 |
|
- |
Cl no 8.12(16018 :2012) |
- |
1000 |
|
- |
Cl no 8.15(16018 :2012) |
- |
1000 |
|
- |
Cl no 8.14(16018 :2012) |
- |
1000 |
|
- |
Cl no 8.17(16018 :2012) |
- |
1000 |
|
- |
Cl no 8.18.1(16018 :2012) |
- |
750 |
|
- |
Cl no 8.18.2(16018 :2012) |
- |
250 |
|
- |
Cl no 8.18.3(16018 :2012) |
- |
250 |
|
- |
Cl no 9.1(16018 :2012) |
- |
1000 |
|
- |
Cl no 9.2(16018 :2012) |
- |
1000 |
|
- |
Cl no 8.4.2(16018 :2012) |
- |
500 |
|
- |
Cl no 8.11.1 to 8.11.3(Discharge assembly) |
- |
1050 |
|
- |
cl-8.9.1(Low pressure cylinder) |
- |
250 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Stainless steel cylinder (Cl. 8.4.2), CO2 cylinders (Cl. 8.4.3), Aluminium cylinder (Cl. 8.5), Class D Fire test (Cl. 7.3), Requirement for plastic components (Cl. 8.10), Pressure gauges for low pressure extinguisher (Cl. 8.16), Gasket and O-rings (Cl. 8.19) |
25 |
IS 1534 : Part 1 (1977) |
Ballasts for fluorescent lamps:Part 1 For switch start circuits |
- |
-
|
20000 View breakup
For BIS Samples – 1.5 times the BIS testing charges.
For others : 20,000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3(General Design, Construction and workmanship) |
- |
500 |
|
ok |
4(Terminals For External Wiring) |
- |
2000 |
|
ok |
5(Screws, Current-Carrying Parts And Connections) |
- |
2000 |
|
ok |
6(Provision For Earthing) |
- |
1000 |
|
ok |
7(Creepage Distances and Clearances) |
- |
500 |
|
ok |
8(Marking) |
- |
500 |
|
ok |
9.4(Visual Examination) |
- |
2500 |
|
ok |
9.5(Protection against Accidental Contacts and Electric Shock) |
- |
750 |
|
ok |
9.6(Voltage Across Capacitors) |
- |
500 |
|
ok |
9.7(Moisture Resistance and Insulation) |
- |
2000 |
|
ok |
9.8(Test for Thermal Endurance Of Windings) |
- |
2000 |
|
ok |
9.9(Test For Limitations Of Ballast Heating) |
- |
1000 |
|
ok |
9.1(Test for Mechanical Strength) |
- |
750 |
|
ok |
9.11(Resistance To Heat) |
- |
1000 |
|
ok |
9.12(Resistance To Corrosion) |
- |
500 |
|
ok |
9.13(Performance) |
- |
3000 |
|
ok |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 10.05.2019 |
26 |
IS 1554 : Part 2 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 2 for working voltages from 3.3 kV up to and including 11 kV (Second Revision) |
11 kv |
-
|
175000 View breakup
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,15,000/- for type test of three core cable Rs. 9000/- for additional test for C1(FR) Rs. 13000/- for additional test for C2(FR-LSH) Rs. 1200/- for copper purity
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(CONDUCTOR) |
- |
30 |
|
Rs 175000 for type test of single core Rs 215000 for type test of three core Rs.9000 for additional test for C1 (FR) Rs.13000 For Additional Test For C2 (FR-LSH) Rs.1200 for copper purity test. |
3.1.1(CONDUCTOR) |
- |
30 |
|
- |
4.1(INSULATION) |
- |
30 |
|
- |
5.1(SCREENING) |
- |
30 |
|
- |
5.1.1(Non-magnetic Metallic Tape for SingleCore Unscreened and Unarmoured Cables) |
- |
50 |
|
- |
6.1(FILLERS AND INNER SHEATH) |
- |
30 |
|
- |
6.2(FILLERS AND INNER SHEATH) |
- |
30 |
|
- |
7.1(ARMOURING) |
- |
30 |
|
- |
7.2(ARMOURING) |
- |
30 |
|
- |
8.1(OUTER SHEATH) |
- |
30 |
|
- |
9.1(CONDUCTOR) |
- |
30 |
|
- |
9.2(CONDUCTOR) |
- |
30 |
|
- |
10.1(CONDUCTOR SCREENING) |
- |
30 |
|
- |
11.1(INSULATION) |
- |
30 |
|
- |
11.2(INSULATION : Thickness of Insulation) |
- |
30 |
|
- |
11.3(INSULATION : Tolerance on Thickness of Insulation) |
- |
30 |
|
- |
11.4(INSULATION : Application of Insulation) |
- |
30 |
|
- |
12.1(INSULATION SCREENING) |
- |
30 |
|
- |
12.2(INSULATION SCREENING) |
- |
30 |
|
- |
12.4(INSULATION SCREENING) |
- |
30 |
|
- |
13.1(CORE IDENTIFICATION) |
- |
30 |
|
- |
13.1.1(CORE IDENTIFICATION) |
- |
30 |
|
- |
14.1(LAYING UP OF CORES) |
- |
30 |
|
- |
15.1(INNER SHEATH (COMMON COVERING)) |
- |
500 |
|
- |
15.2(INNER SHEATH (COMMON COVERING)) |
- |
500 |
|
- |
15.3(INNER SHEATH (COMMON COVERING)) |
- |
500 |
|
- |
15.4(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
500 |
|
- |
15.4.1(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
500 |
|
- |
16.1.1(ARMOURING : Application) |
- |
30 |
|
- |
16.1.2(ARMOURING : Application) |
- |
30 |
|
- |
16.1.3(ARMOURING : Direction of lay ) |
- |
30 |
|
- |
16.1.4(ARMOURING : Application) |
- |
30 |
|
- |
16.2.1(ARMOURING : Type of Armour) |
- |
30 |
|
- |
16.2.2(ARMOURING : Type of Armour) |
- |
30 |
|
- |
16.3(Armouring : Dimensions -Wire Diameter) |
- |
1000 |
|
- |
16.3(Armouring : Dimensions -Formed wire ) |
- |
1000 |
|
- |
16.4(ARMOURING : Joints) |
- |
30 |
|
- |
16.5(ARMOURING : Resistance) |
- |
1000 |
|
- |
13.6 a)(ARMOURING: Tensile Strength) |
- |
750 |
|
- |
13.6 b)(ARMOURING: Elongation ) |
- |
750 |
|
- |
13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
500 |
|
- |
13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
500 |
|
- |
13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
500 |
|
- |
13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
500 |
|
- |
13.6 g)(ARMOURING: Resistivity) |
- |
1000 |
|
- |
17.1(OUTER SHEATH) |
- |
30 |
|
- |
17.2(OUTER SHEATH : colour ) |
- |
30 |
|
- |
17.3.1(Thickness of Outer Sheath : Unarmoured Cables) |
- |
500 |
|
- |
17.3.2(Thickness of Outer Sheath : Armoured Cables) |
- |
500 |
|
- |
18.1 a) 1)(Tests on Conductor : Annealing test (for copper)) |
- |
1000 |
|
- |
18.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
500 |
|
- |
18.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
500 |
|
- |
18.1 a) 3)(Tests on Conductor : Wrapping test ( for aluminium)) |
- |
500 |
|
- |
18.1 a)4)(Tests on conductor : Conductor resistance test - Main conductor ) |
- |
750 |
|
- |
18.1 a)4)(Resistance test - Neutral conductor ) |
- |
750 |
|
- |
18.1 d) 1)(Phyaical tests for insulation : Tensile Test) |
- |
750 |
|
- |
18.1 d) 1)(Phyaical tests for insulation : Elongation ) |
- |
750 |
|
- |
18.1 d) 1)(Physical tests for sheath : Tensile stregth ) |
- |
750 |
|
- |
18.1 d) 1)(Physical tests for sheath : Elongation ) |
- |
750 |
|
- |
18.1 d) 2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
1250 |
|
- |
18.1 d) 2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
1250 |
|
- |
18.1 d) 2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
1250 |
|
- |
18.1 d) 2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
1250 |
|
- |
18.1 d) 2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
1250 |
|
- |
18.1 d) 2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
1250 |
|
- |
18.1 d) 2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
1250 |
|
- |
18.1 d) 2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
1250 |
|
- |
18.1 d) 3)(Phyaical tests for insulation : Shrinkage ) |
- |
500 |
|
- |
18.1 d) 3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
500 |
|
- |
18.1 d) 3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
500 |
|
- |
18.1 d) 3)(Phyaical tests for Sheath : Shrinkage ) |
- |
500 |
|
- |
18.1 d) 4)(Hot deformation : Insulation ) |
- |
750 |
|
- |
18.1 d) 4)(Hot deformation : Sheath ) |
- |
750 |
|
- |
18.1 d) 5)( Loss of mass in air oven- Insulation ) |
- |
1500 |
|
- |
18.1 d) 5)( Loss of mass in air oven- sheath ) |
- |
1500 |
|
- |
18.1 d) 6)(Heat shock test- Insulation ) |
- |
250 |
|
- |
18.1 d) 6)(Heat shock test- sheath ) |
- |
250 |
|
- |
18.1 d) 7)(Thermal stability- insulation ) |
- |
750 |
|
- |
18.1 d) 7)(Thermal stability- Sheath ) |
- |
750 |
|
- |
18.1 d) 8)(Water absorption (gravimetric)(for insulation, where applicable)) |
- |
2000 |
|
- |
18.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
1000 |
|
- |
18.1 e)(Insulation resistance test : IR Constant ) |
- |
1000 |
|
- |
19.2(Partial discharge test) |
- |
27000 |
|
- |
19.3(Bending test) |
- |
500 |
|
- |
19.4(Dielectric power factor test) |
- |
9500 |
|
- |
19.4(Dielectric power factor test) |
- |
9500 |
|
- |
19.5(Heating cycle test) |
- |
27000 |
|
- |
19.6(Impulse withstand test) |
- |
32000 |
|
- |
19.7(High voltage test) |
- |
4000 |
|
- |
19.8(Flammability test) |
- |
750 |
|
- |
19.9(Oxygen Index Test) |
- |
3000 |
|
- |
19.10(Flame Retardance Test on Single Cables) |
- |
1500 |
|
- |
19.11(Flame Retardance Test on Bunched Cables) |
- |
3000 |
|
- |
19.13(Test for Halogen Acid Gas Evolution) |
- |
3000 |
|
- |
19.14(Temperature Index) |
- |
3000 |
|
- |
18.4(Optional Test : Cold Impact ) |
- |
500 |
|
- |
20.1(IDENTIFICATION : Manufacturer's Identification) |
- |
20 |
|
- |
20.2(IDENTIFICATION : Cable Identification) |
- |
20 |
|
- |
20.3(IDENTIFICATION : Cable Code) |
- |
20 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 10.05.2019 |
27 |
IS 12592 (2002) |
Precast concrete manhole cover and frame - Specification (First Revision) |
- |
-
|
15800 View breakup
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 10,000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3(Grade) |
- |
250 |
|
- |
3(Type/Shape of Cover) |
- |
250 |
|
- |
4.4(Reinforcement) |
- |
2000 |
|
- |
4.5(Steel Fibres - Diameter / equivalent diameterofsteel tibres) |
- |
500 |
|
- |
4.5(Steel Fibres - The aspect ratio of the tibres) |
- |
500 |
|
- |
5.2 and Table 1(Dimensions of Frame - A) |
- |
300 |
|
- |
5.2 and Table 1(Dimensions of Frame - B) |
- |
300 |
|
- |
5.2 and Table 1(Dimensions of Frame - C) |
- |
300 |
|
- |
5.2 and Table 1(Dimensions of Frame - D) |
- |
300 |
|
- |
5.2 and Table 1(Dimensions of Frame - E) |
- |
300 |
|
- |
5.2 and Table 1(Dimensions of Frame - F) |
- |
300 |
|
- |
5.2(Dimensions of cover- Diameter) |
- |
300 |
|
- |
5.2(Clearance at top between the frame and the cover all round the periphery) |
- |
300 |
|
- |
5.2(Top surface ofthe frame and cover is in level) |
- |
300 |
|
- |
5.2 and Fig 1(Distance of housing from the edge) |
- |
300 |
|
- |
5.2 and Fig 1(Clear cover to reinforcement) |
- |
300 |
|
- |
5.2(Suitable taper matching with taper given for the frame shall be provided to the periphery of the cover) |
- |
350 |
|
- |
7.4.1(Edge Protection and Finishing - Frame) |
- |
500 |
|
- |
7.4.1(Edge Protection and Finishing - Frame) |
- |
350 |
|
- |
7.4.1(Edge Protection and Finishing - Frame) |
- |
350 |
|
- |
7.4.1(Edge Protection and Finishing - Frame) |
- |
350 |
|
- |
7.4.2(Edge Protection and Finishing - Cover) |
- |
500 |
|
- |
7.4.2(Edge Protection and Finishing - Cover) |
- |
350 |
|
- |
7.4.2(Edge Protection and Finishing - Cover) |
- |
350 |
|
- |
7.4.2(Edge Protection and Finishing - Cover) |
- |
350 |
|
- |
8(LIFTING HOOKS) |
- |
1000 |
|
- |
8(LIFTING HOOKS) |
- |
1000 |
|
- |
9.1(General) |
- |
250 |
|
- |
9.3 and Table and
Annex C(Load Test) |
- |
6400 |
|
- |
4.4(Reinforcement) |
- |
500 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Up to dimension 760 mm only |
28 |
IS 15683 (2018) |
Portable Fire Extinguishers — Performance and Construction — Specification ( First Revision ) |
- |
-
|
99700 View breakup
For BIS Samples – 1.5 times the BIS testing charges.
Rs.23700/- (except fire performance test) Fire Performance test: Rs.9000/- for 1A Class Rs.11000/- for 2A Class Rs.12000/- for 3A Class Rs.16000/- for 4A Class Rs.27500/- for 6A Class Rs.33000/- for 10A Class Rs.46000/- for 15A Class Rs.66000/- for 20A Class Rs.3000/- for 8B Class Rs.4000/- for 13B Class Rs.5000/- for 21B Class Rs.6000/- for 34B Class Rs.32000/- for 55 B Class Rs.36000/- for 70 B Class Rs.46000/- for 89 B Class Rs.51000/- for 113 B Class Rs.60000/- for 144B Class Rs.65000/- for 183B Class Rs.75000/- for 233B Class Rs.2000/- for 5F Class Rs.6000/- for 15F Class Rs.10000/- for 25F Class Rs.20000/- for 75F Class Splash Test : Rs.1500/- for 5F Class Rs.4500/- for 15A Class Rs.7500/- for 25F Class Rs.15000/- for 75F Class Electrical conductivity test- Rs. 15,000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 5.3.1(Filling Requirements) |
- |
750 |
|
- |
Cl. 5.3.2(Filling Requirements) |
- |
750 |
|
- |
Cl. 5.3.2(Filling Requirements) |
- |
750 |
|
- |
Cl. 5.3.2(Filling Requirements) |
- |
750 |
|
- |
Cl. 5.3.2(Filling Requirements) |
- |
750 |
|
- |
Cl. 5.3.2(Filling Requirements) |
- |
750 |
|
- |
Cl. 5.3.2(Filling Requirements) |
- |
750 |
|
- |
Cl. 5.3.3(Capacities) |
- |
250 |
|
- |
Cl. 5.3.3(Capacities) |
- |
250 |
|
- |
Cl. 5.3.3(Capacities) |
- |
250 |
|
- |
Cl. 5.3.3(Capacities) |
- |
250 |
|
- |
Cl. 5.3.3(Capacities) |
- |
250 |
|
- |
Cl. 5.3.3(Capacities) |
- |
250 |
|
- |
Cl. 6(PRESSURE REQUIREMENTS FOR LOW PRESSURE EXTINGUISHERS) |
- |
1500 |
|
- |
Cl. 7.1(GENERAL OPERATING PERFORMANCE REQUIREMENTS) |
- |
250 |
|
- |
Cl. 6(PRESSURE REQUIREMENTS FOR LOW PRESSURE EXTINGUISHERS) |
- |
1500 |
|
- |
Cl. 7.2 - Table 1(GENERAL OPERATING PERFORMANCE REQUIREMENTS) |
- |
500 |
|
- |
Cl. 7.2 - Table 1(GENERAL OPERATING PERFORMANCE REQUIREMENTS) |
- |
500 |
|
- |
Cl. 7.3(Resistance to Temperature changes) |
- |
1500 |
|
- |
Cl 7.4.3( Leakage Test) |
- |
500 |
|
- |
Cl 7.5.1(Impact Resistance Test) |
- |
750 |
|
- |
Cl 7.5.2(Vibration Resistance Test) |
- |
1000 |
|
- |
Cl 7.6(Resistance to Corrosion) |
- |
2000 |
|
- |
Cl 7.7(Tapping Test) |
- |
750 |
|
- |
Cl 7.8(Intermittent Discharge Test) |
- |
750 |
|
- |
Cl 8.1(Rating Suitability for the Various Classes of Fire) |
- |
750 |
|
24700 Rs Except Fire Test
Fire Performance Test:
9000 -1A 11000 - 2A 12000 - 3A 16000 -4A 27500 -6A 33000 -10A 46000 -15A 66000 -20A
3000 -8B 4000 -13B 5000 -21B 6000 -34B 32000 -55B 36000 -70B 46000 -89B 51000 113B 60000 -144B 65000 -183B 75000 -233B |
Cl 8.6(Electrical Conductivity of Extinguisher Discharge) |
- |
15000 |
|
- |
Cl 9.2.2(Burst Test) |
- |
750 |
|
- |
Cl 9.2.3(Crushing Test) |
- |
700 |
|
- |
Cl 9.2.4(Pressure Cycling Test) |
- |
1000 |
|
- |
Cl 9.2.5(Welded Low Carbon Steel Cylinder) |
- |
500 |
|
- |
Cl 9.2.6(Stainless Steel Cylinders) |
- |
500 |
|
- |
Cl 9.3(Carrying Handle) |
- |
500 |
|
- |
Cl 9.4(Mounting) |
- |
500 |
|
- |
Cl 9.5(Caps, Valves and Closures) |
- |
750 |
|
- |
Cl 9.8(Hose Assemblies) |
- |
1000 |
|
- |
Cl 9.2.7(Aluminium Cylinders) |
- |
500 |
|
- |
Cl 9.7.1(Requirements for Plastics Components) |
- |
500 |
|
- |
Cl 9.7.2(Requirements for Plastics Components) |
- |
500 |
|
- |
Cl 9.7.3(Requirements for Plastics Components) |
- |
500 |
|
- |
Cl 9.8(Hose Assemblies) |
- |
1000 |
|
- |
Cl 9.9 - Table 10(Method of Operation) |
- |
750 |
|
- |
Cl 9.10(Safety-Locking Devices) |
- |
750 |
|
- |
Cl 9.12(Dip-Tubes and Filters — Water-Based Extinguishers) |
- |
500 |
|
- |
Cl 9.13(Horn Test for Carbon Dioxide (CO2) Extinguishers) |
- |
1000 |
|
- |
Cl 9.14(Requirements for Extinguishants Filled in the Extinguisher) |
- |
2000 |
|
- |
Cl 10(MARKING AND COLOUR) |
- |
250 |
|
- |
Cl 7.8(Intermittent Discharge Test) |
- |
750 |
|
- |
Cl 9(CONSTRUCTION REQUIREMENTS) |
- |
250 |
|
- |
9.1(General Requirements of High Pressure Extinguisher) |
- |
1000 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Class D Fire test (Cl. 8.1.4 & 8.5), High pressure extinguisher (Cl. 9.1), Requirements for Pressure gauges and indicators for low pressure extinguishers (Cl. 9.11) |
29 |
IS 7098 : Part 2 (2011) |
Crosslinked polyethylene insulated thermoplastic sheathed cables - Specification: Part 2 for working voltages from 3.3 kV up to and including 33 kV (Second Revision) |
33 KV |
-
|
175000 View breakup
for BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,15,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 13000/- for additional test for C2(FR-LSH) Rs. 1200/- for copper purity
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(CONDUCTOR) |
- |
30 |
|
RS 175000 for type test of single core cable Rs 215000 for type test of three core cable Rs. 9000 for additional test for C1 (FR) Rs. 13000 For Additional Test For C2 (FR-LSH) Rs. 1200 for cupper purity |
4.1.1(CONDUCTOR) |
- |
30 |
|
- |
5(INSULATION) |
- |
30 |
|
- |
6(SCREENING) |
- |
30 |
|
- |
6.1.1(SCREENING : - Non-metallic — Semiconducting Compound) |
- |
30 |
|
- |
6.1.2(SCREENING : - Non-magnetic Metallic Tape for Single Core Unscreened and Unarmoured Cables) |
- |
30 |
|
- |
7(FILLERS AND INNER SHEATH) |
- |
30 |
|
- |
8.1(ARMOURING) |
- |
30 |
|
- |
8.2(ARMOURING) |
- |
30 |
|
- |
9(OUTER SHEATH ) |
- |
30 |
|
- |
10.1(CONDUCTOR) |
- |
30 |
|
- |
10.2(CONDUCTOR) |
- |
30 |
|
- |
11(CONDUCTOR SCREENING) |
- |
30 |
|
- |
12.1(INSULATION) |
- |
30 |
|
- |
12.2(INSULATION : Thickness of Insulation) |
- |
500 |
|
- |
12.3(INSULATION : Tolerance on Thickness of Insulation) |
- |
500 |
|
- |
12.4(Eccentricity and Ovality) |
- |
500 |
|
- |
12.5(INSULATION : Application of Insulation) |
- |
30 |
|
- |
13.1(INSULATION SCREENING) |
- |
30 |
|
- |
13.2(INSULATION SCREENING) |
- |
30 |
|
- |
13.3(INSULATION SCREENING) |
- |
30 |
|
- |
14.1(CORE IDENTIFICATION) |
- |
30 |
|
- |
14.1.1(CORE IDENTIFICATION) |
- |
30 |
|
- |
15.1(LAVING UP OF CORES) |
- |
30 |
|
- |
16.1(INNER SHEATH (COMMON COVERING)) |
- |
500 |
|
- |
16.2(INNER SHEATH (COMMON COVERING)) |
- |
500 |
|
- |
16.2.1(INNER SHEATH (COMMON COVERING)) |
- |
500 |
|
- |
16.3(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
500 |
|
- |
16.3.1(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
500 |
|
- |
17.1(ARMOURING : Application ) |
- |
30 |
|
- |
17.1.3(ARMOURING ) |
- |
30 |
|
- |
17.2(ARMOURING : Type of armour ) |
- |
30 |
|
- |
17.2.1(ARMOURING : Type of armour ) |
- |
30 |
|
- |
17.2(ARMOURING : Coverage ) |
- |
500 |
|
- |
17.3(ARMOURING : Dimension ) |
- |
1000 |
|
- |
17.4(ARMOURING : Joints) |
- |
30 |
|
- |
16.4(ARMOURING : Resistance) |
- |
500 |
|
- |
18.1(OUTER SHEATH) |
- |
30 |
|
- |
18.2(OUTER SHEATH: Colour) |
- |
30 |
|
- |
18.3(Thicknes of outer sheath : average ) |
- |
500 |
|
- |
18.3(Thicknes of outer sheath : minimum ) |
- |
500 |
|
- |
19.1 i) a)(Annealing test (for copper)) |
- |
1000 |
|
- |
19.1 i) b)(Tensile test (for aluminium) - Before stranding ) |
- |
750 |
|
- |
19.1 i) b)(Tensile test (for aluminium) - After stranding ) |
- |
750 |
|
- |
19.1 i) c)(Wrapping test ( for aluminium)) |
- |
500 |
|
- |
19.1 i) d)(Resistance test - Main conductor ) |
- |
500 |
|
- |
19.1 i) d)(Resistance test - Neutral conductor ) |
- |
500 |
|
- |
19.1 iii) a)(Phyaical tests for insulation : Tensile Test) |
- |
750 |
|
- |
19.1 iii) a)(Phyaical tests for insulation : Elongation ) |
- |
750 |
|
- |
19.1 iii) b)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
750 |
|
- |
19.1 iii) b)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
750 |
|
- |
19.1 iii) c)(Degree of cross linking ) |
- |
30 |
|
- |
19.1 iii) d)(Phyaical tests for insulation : Hot set ) |
- |
1000 |
|
- |
19.1 iii) d)(Phyaical tests for insulation : Permanent set ) |
- |
1000 |
|
- |
19.1 iii) e)(Phyaical tests for insulation : Shrinkage ) |
- |
500 |
|
- |
19.1 iii) e)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
500 |
|
- |
19.1 iii) f)(Insulation: Waterabsorption(gravimetric)) |
- |
2000 |
|
- |
19.1 v) a)(Test for strippability of semiconducting strippable insulation screen
(when applicable)) |
- |
1000 |
|
- |
19.1 v) b)(Volume resistivity) |
- |
1000 |
|
- |
19.1 vi) a)(Physical tests for outer sheath : Tensile stregth ) |
- |
750 |
|
- |
19.1 vi) a)(Physical tests for outer sheath : Elongation ) |
- |
750 |
|
- |
19.1 vi) b)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
750 |
|
- |
19.1 vi) b)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
750 |
|
- |
19.1 vi) b)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
750 |
|
- |
19.1 vi) b)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
750 |
|
- |
19.1 vi) c)(Phyaical tests for Sheath : Shrinkage ) |
- |
500 |
|
- |
19.1 vi) c)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
500 |
|
- |
19.1 vi) d)(Sheath : Hot deformation) |
- |
750 |
|
- |
19.1 vi) e)(Loss of massIn air oven) |
- |
2000 |
|
- |
19.1 vi) f)(Sheath : Heat shock test) |
- |
500 |
|
- |
19.1 vi) g)(Sheath : Thermalstability) |
- |
500 |
|
- |
19.1 vi) h)(Carbon black content of polythene
sheath ) |
- |
1500 |
|
- |
19.1 vii)(Thermal ageing test for complete cable - Tensile stregth ) |
- |
750 |
|
- |
19.1 vii)(Thermal ageing test for complete cable- Elogation ) |
- |
750 |
|
- |
19.1 vii)(Thermal ageing test for complete cable- Resistivity ) |
- |
750 |
|
- |
19.1 xi)(Insulation resistance test : volume resistivity ) |
- |
1000 |
|
- |
20.2(Partial discharge test) |
- |
25000 |
|
- |
20.3(Bending test) |
- |
500 |
|
- |
20.4(Dielectric power factor test : As a function of voltage) |
- |
10000 |
|
- |
20.4(Dielectric power factor test : As a function of temperature) |
- |
10000 |
|
- |
20.5(Heating Cycle Test) |
- |
25000 |
|
- |
20.6(Impulse withstand test
(Rated voltage, kV 3.8/6.6
Impulse voltage, kV 60)) |
- |
30000 |
|
- |
20.7(High voltage test) |
- |
30000 |
|
- |
20.8(Flammability test) |
- |
750 |
|
- |
20.1(Oxygen Index Test) |
- |
2500 |
|
- |
20.11(Flame Retardance Test on Single Cables) |
- |
1500 |
|
- |
20.12(Flame Retardance Test on Bunched Cables) |
- |
2000 |
|
- |
20.13(Test for Halogen Acid Gas Evolution) |
- |
2000 |
|
- |
20.14( Test for Smoke Density) |
- |
2000 |
|
- |
20.15(Temperature Index) |
- |
2000 |
|
- |
21.1(IDENTIFICATION : Manufacturer's Identification) |
- |
30 |
|
- |
21.2(IDENTIFICATION : Cable Identification) |
- |
30 |
|
- |
21.3(IDENTIFICATION : Cable Code) |
- |
30 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 10.05.2019 |
30 |
IS 4989 (2018) |
Foam concentrate for producing mechanical foam for fire fighting - Specification (Fourth Revision) |
- |
-
|
34500 View breakup
For BIS Samples – 1.5 times the BIS testing charges. For others Rs. 10,250/- except Fire tests For fire test :Rs. 22,000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 4.1, Table 1, Sr. No. 1 (Visual Examination ) |
- |
0 |
|
- |
Cl. 4.1, Table 1, Sr. No. 2(Freezing and thrawing) |
- |
0 |
|
- |
Cl. 4.1, Table 1, Sr. No. 3(pH (Original Sample)) |
- |
0 |
|
- |
Cl. 4.1, Table 1, Sr. No. 3(pH (ageing Sample)) |
- |
0 |
|
- |
Cl. 4.1, Table 1, Sr. No. 4(Miscibility with distilled water) |
- |
0 |
|
- |
Cl. 4.1, Table 1, Sr. No. 5(Viscosity) |
- |
0 |
|
- |
Cl. 4.1, Table 1, Sr. No. 6(pour point) |
- |
0 |
|
- |
Cl. 4.1, Table 1, Sr. No. 7(Sludge content) |
- |
0 |
|
- |
Cl. 4.1, Table 1, Sr. No. 8(Surface tension) |
- |
0 |
|
- |
Cl. 4.1, Table 1, Sr. No. 10(spreading coefficient) |
- |
0 |
|
- |
Clause No. 4.2, Sr. No. I of Table 2, Annex-J(Expansion) |
- |
1000.00 |
|
- |
Clause No. 4.2, Sr. No. II of Table 2, Annex-J(25% Drainage Time) |
- |
1000.00 |
|
- |
Clause No. 4.2, Sr. No. III(a) of Table 2, Annex-K(Fire Control Time for Hydrocarbon Fires (Non Polar) with potable water) |
- |
22000.00 |
|
With single fire test only. for other additional charges will be added as 22000.00 per fire test. |
Clause No. 4.2, Sr. No. III(b) of Table 2, Annex-K(Fire Extinction Time for Hydrocarbon Fires (Non Polar) with potable water) |
- |
22000.00 |
|
With single fire test only. for other additional charges will be added as 22000.00 per fire test. |
Clause No. 4.2, Sr. No. III(c) of Table 2, Annex-K(Sealability/Film forming for Hydrocarbon Fires (Non Polar) with potable water) |
- |
22000.00 |
|
With single fire test only. for other additional charges will be added as 22000.00 per fire test. |
Clause No. 4.2, Sr. No. III(d) of Table 2, Annex-K(Burn Back for Hydrocarbon Fires (Non Polar) with potable water) |
- |
22000.00 |
|
With single fire test only. for other additional charges will be added as 22000.00 per fire test. |
Clause No. 4.2, Sr. No. III(a) of Table 2, Annex-K(Fire Control Time for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
22000.00 |
|
12500 Rs. Except Fire Test
single fire test : 22000.00 Rs
Double fire test : 44000.00 Rs
Triple fire test : 66000.00 Rs
Fourth Time fire test : 88000.00 Rs |
Clause No. 4.2, Sr. No. III(b) of Table 2, Annex-K(Fire Extinction Time for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
22000.00 |
|
With single fire test only. for other additional charges will be added as 22000.00 per fire test. |
Clause No. 4.2, Sr. No. III(c) of Table 2, Annex-K(Sealability/Film forming for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
22000.00 |
|
With single fire test only. for other additional charges will be added as 22000.00 per fire test. |
Clause No. 4.2, Sr. No. III(d) of Table 2, Annex-K(Burn Back for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
22000.00 |
|
With single fire test only. for other additional charges will be added as 22000.00 per fire test. |
Clause No. 4.2, Sr. No. IV(a) of Table 2, Annex-M(Fire Control Time for Polar Solvent Fire) |
- |
22000.00 |
|
With single fire test only. for other additional charges will be added as 22000.00 per fire test. |
Clause No. 4.2, Sr. No. IV(b) of Table 2, Annex-M(Fire Extinction Time Polar Solvent Fire) |
- |
22000.00 |
|
With single fire test only. for other additional charges will be added as 22000.00 per fire test. |
Clause No. 4.2, Sr. No. IV(c) of Table 2, Annex-M(Sealability/Film forming for Polar Solvent Fires) |
- |
22000.00 |
|
With single fire test only. for other additional charges will be added as 22000.00 per fire test. |
Clause No. 4.2, Sr. No. IV(d) of Table 2, Annex-M(Burn Back for Polar Solvent Fires) |
- |
22000.00 |
|
With single fire test only. for other additional charges will be added as 22000.00 per fire test. |
Clause No. 4.2, Sr. No. IV(a) of Table 2, Annex-M(Fire Control Time for Polar Solvent Fire with synthetic sea water) |
- |
22000.00 |
|
With single fire test only. for other additional charges will be added as 22000.00 per fire test. |
Clause No. 4.2, Sr. No. IV(b) of Table 2, Annex-M(Fire Extinction Time Polar Solvent Fire with synthetic sea water) |
- |
22000.00 |
|
With single fire test only. for other additional charges will be added as 22000.00 per fire test. |
Clause No. 4.2, Sr. No. IV(c) of Table 2, Annex-M(Sealability/Film forming for Polar Solvent Fires with synthetic sea water) |
- |
22000.00 |
|
With single fire test only. for other additional charges will be added as 22000.00 per fire test. |
Clause No. 4.2, Sr. No. IV(d) of Table 2, Annex-M(Burn Back for Polar Solvent Fires with synthetic sea water) |
- |
22000.00 |
|
With single fire test only. for other additional charges will be added as 22000.00 per fire test. |
Clause No. 4.2, Sr. No. IV of Table 1, Annex-C(Specific Gravity of original sample) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. IV of Table 1, Annex-C(Specific Gravity of aged sample) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. I of Table 1, Annex-A-1(Visual Examination) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. II of Table 1, Annex-A-2(Freezing and thawing) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. III of Table 1, Annex-B(pH of original sample) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. III of Table 1, Annex-B(pH of aged sample) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. V of Table 1, Annex-D(Misciblity with distilled water) |
- |
1000 |
|
- |
Clause No. 4.2, Sr. No. VI of Table 1, using viscosity meter see sl No. (iv) of table 2 of IS 1206 (Part 3)(Viscosity (Kinematic)) |
- |
1200 |
|
- |
Clause No. 4.2, Sr. No. VII of Table 1, Annex-E(Pour Point) |
- |
1000 |
|
- |
Clause No. 4.2, Sr. No. VIII of Table 1, Annex-F(Sludge Content for Original Sample) |
- |
1000 |
|
- |
Clause No. 4.2, Sr. No. IX of Table 1, Annex-G(Surface Tension) |
- |
1500 |
|
- |
Clause No. 4.2, Sr. No. X of Table 1, Annex-G(Spreading Coefficient) |
- |
1800 |
|
- |
Clause No. 4.2, Sr. No. VIII of Table 1, Annex-F(Sludge Content for Aged Sample) |
- |
1000 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 10.05.2019 |