1 |
IS 17550 : Part 3 (2025) |
Household Refrigerating Appliances - Characteristics and Methods Of Test Part 3 Energy Consumption and Volume (First Revision) |
Household Refrigerating Appliances |
155000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 4.1, Annex A(set up for energy consumption) |
- |
25000 |
|
- |
Clause 4.2, Annex B(Steady state power consumption) |
- |
25000 |
|
- |
Clause 4.3, Annex C(Defrost and Recovery Energy and Temperature Change) |
- |
25000 |
|
- |
Clause 4.4, Annex D(Defrost Frequency) |
- |
20500 |
|
- |
Clause 4.5, Annex E(Number of Test Points and Interpolation) |
- |
17500 |
|
- |
Clause 4.6, Annex G(Load Processing Efficiency) |
- |
17500 |
|
- |
Clause 4.7, Annex F(Specified Auxiliaries) |
- |
17500 |
|
- |
Clause 4.8, Annex H(Volume determination) |
- |
9500 |
|
- |
Clause 4.8.1, Annex H(Rated total volume) |
- |
9500 |
|
- |
Clause 5, 5.1, 5.2 Table 1(TARGET TEMPERATURES FOR ENERGY DETERMINATION) |
- |
0 |
|
- |
Clause 6, 6.1 to 6.8(DETERMINATION OF ENERGY CONSUMPTION) |
- |
25000 |
|
- |
|
19 Mar, 2026 |
- Included w.e.f.22.07.2025 |
2 |
IS 17681 (2022) |
Specification for Bottled water dispensers |
Bottled Water Dispensers |
230000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Construction) |
- |
1000 |
|
- |
4.1(General Design) |
- |
1000 |
|
- |
4.2(Materials) |
- |
1000 |
|
- |
4.3(Finish) |
- |
1000 |
|
- |
4.5(Hardware) |
- |
1000 |
|
- |
4.6(Disposal of Waste Water) |
- |
1000 |
|
- |
4.7(Hot Water Tank) |
- |
1000 |
|
- |
4.8(Hermetically Sealed Compressor) |
- |
1000 |
|
- |
4.9(Protective Guards) |
- |
1000 |
|
- |
5(Refrigeration System) |
- |
1000 |
|
- |
5.1(Pipes and Connections/Fitting) |
- |
1000 |
|
- |
5.2(Control of Operation) |
- |
1000 |
|
- |
6.1(General) |
- |
12500 |
|
- |
6.1(Protection against electric shock (Cl. 8 of IS 302-2-24)) |
- |
12500 |
|
- |
6.1(Power Input & Current (Cl. 10 of IS 302-2-24)) |
- |
12500 |
|
- |
6.1(Temperature Rise/ Heating (Cl. 11 of IS 302-2-24)) |
- |
12500 |
|
- |
6.1("Insulation Resistance and Electric Strength/ Leakage Current and Electric Strength
(Cl. 13 of IS 302-2-24)") |
- |
12500 |
|
- |
6.1("Moisture Resistance
(Cl. 15 of IS 302-2-24)") |
- |
12500 |
|
- |
6.1("Insulation resistance and electric strength
(After humidity treatment)
(Cl. 16 of IS 302-2-24)") |
- |
12500 |
|
- |
6.1("Provision For Earthing
(Cl. 27 of IS 302-2-24)") |
- |
12500 |
|
- |
6.1("Screws & Connections
(Cl. 28 of IS 302-2-24)") |
- |
12500 |
|
- |
6.2(Electrical Accessories) |
- |
1000 |
|
- |
6.3(Salt Mist Test) |
- |
21000 |
|
- |
7(Sound pressure level) |
- |
12500 |
|
- |
10.1(Cooling Capacity Test) |
- |
22500 |
|
- |
10.2(Maximum Operating Condition Test (Environmental)) |
- |
22500 |
|
- |
10.3(Maximum Operating Condition Test (Voltage)) |
- |
17500 |
|
- |
10.4(Heating Capacity Test) |
- |
27500 |
|
- |
10.5(Annual Energy Consumption Test) |
- |
27500 |
|
- |
10.6(Freeze-up Test) |
- |
27500 |
|
- |
10.7(Door Opening and Closing Test) |
- |
17500 |
|
- |
10.8(Door Seal Test) |
- |
5000 |
|
- |
10.9(Pull-down Test) |
- |
10000 |
|
- |
11(Marking and instruction) |
- |
2500 |
|
- |
4.4(Thermal Insulation) |
- |
1000 |
|
- |
|
19 Mar, 2026 |
- Included w.e.f.22.07.2025 |
3 |
IS 7872 (2020) |
Deep Freezers - Specification ( Second Revision ) |
Deep Freezers |
162500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
10.2.12(Temperature rise test) |
- |
10000 |
|
- |
10.2.11(Measurement ) |
- |
0 |
|
- |
10.2.10.1(Test packages and life time) |
- |
0 |
|
- |
10.2.10(Full load test) |
- |
0 |
|
- |
10.2.8(Earth resistance test ) |
- |
0 |
|
- |
10.2.7(Leakage current test ) |
- |
0 |
|
- |
10.2.6(Insulation resistance test) |
- |
0 |
|
- |
10.2.5(High voltage test) |
- |
0 |
|
- |
10.2.3(Thermal insulation test ) |
- |
5000 |
|
- |
10.2.2(Machanical strength of shelves and similar components) |
- |
4000 |
|
- |
10.2.1(Door seal test ) |
- |
4000 |
|
- |
9.2.2(Power consumption & percentage running time) |
- |
0 |
|
- |
9.2.1(Pull down time) |
- |
10000 |
|
- |
9.1(No load test) |
- |
0 |
|
- |
6.11(Volume measurement Water fill method) |
- |
0 |
|
- |
6(Measurement of freezer storage
capacity) |
- |
7500 |
|
- |
5.1(Sound level) |
- |
5000 |
|
- |
5.6(External surface condensation test) |
- |
5000 |
|
- |
5.5(Strength Pressure test for components) |
- |
5000 |
|
- |
4.8(Doors & Fittings) |
- |
5000 |
|
- |
13(Marking and Instruction) |
- |
1000 |
|
- |
11.7(Pressure Test) |
- |
5000 |
|
- |
11.6(Thermal Insulation Test ( External Condensation)) |
- |
5000 |
|
- |
11.5(Mechanical Strength of Shelves and Similar Components) |
- |
4000 |
|
- |
11.4(Door Seal Test) |
- |
4000 |
|
- |
11.3(Temperature Rise Test) |
- |
10000 |
|
- |
11.2(Energy Consumption Test) |
- |
22500 |
|
- |
11.1(No load Pull down Test) |
- |
10000 |
|
- |
8(Freezer Storage Capacity) |
- |
7500 |
|
- |
7(Sound Pressure Level) |
- |
5000 |
|
- |
6(Safety Requirements) |
- |
10000 |
|
- |
5.4.4(Fatigue Test) |
- |
5000 |
|
- |
5.4.3(Individual Strength - Pressure Test) |
- |
5000 |
|
- |
5.4.2(Individual Strength - Pressure Test) |
- |
5000 |
|
- |
4.8(Door and Fittings) |
- |
5000 |
|
- |
13(Marking and Instruction) |
- |
1000 |
|
- |
11.7(Pressure Test) |
- |
5000 |
|
- |
11.6(Thermal Insulation Test ( External Condensation)) |
- |
5000 |
|
- |
11.5(Mechanical Strength of Shelves and Similar Components) |
- |
4000 |
|
- |
11.4(Door Seal Test) |
- |
4000 |
|
- |
11.3(Temperature Rise Test) |
- |
10000 |
|
- |
11.2(Energy Consumption Test) |
- |
22500 |
|
- |
11.1(No load Pull down Test) |
- |
10000 |
|
- |
8(Freezer Storage Capacity) |
- |
7500 |
|
- |
7(Sound Pressure Level) |
- |
5000 |
|
- |
6(Safety Requirements) |
- |
71000 |
|
- |
5.4.4(Fatigue Test) |
- |
5000 |
|
- |
5.4.3(Individual Strength - Pressure Test) |
- |
5000 |
|
- |
5.4.2(Individual Strength - Pressure Test) |
- |
5000 |
|
- |
4.8(Door and Fittings) |
- |
5000 |
|
- |
5(Refrigeration system) |
- |
5000 |
|
- |
Cl-4.1(General Design) |
- |
5000 |
|
- |
Cl-4.2(Materials) |
- |
5000 |
|
- |
Cl-4.3(Finish) |
- |
5000 |
|
- |
Cl-4.4(Thermal Insulation) |
- |
4000 |
|
- |
Cl-4.5(Fittings) |
- |
5000 |
|
- |
Cl-4.6(Hardware) |
- |
5000 |
|
- |
Cl-4.7(Interior Fittings) |
- |
5000 |
|
- |
Cl-4.8(Doors and Fittings) |
- |
5000 |
|
- |
Cl-4.9(Disposal of Defrost / Condensate Water) |
- |
5000 |
|
- |
Cl-5.1(Construction) |
- |
5000 |
|
- |
Cl-5.2(Control of Operation) |
- |
5000 |
|
- |
Cl-5.3(Location of Components) |
- |
5000 |
|
- |
6.5(For flammable refrigerant the units should comply with
IS/IEC 60335-2-89) |
- |
500 |
|
- |
6.2(The compressor shall comply with the requirements
of IS 10617) |
- |
500 |
|
- |
|
19 Mar, 2026 |
- Included w.e.f.22.07.2025 |
4 |
IS 2167 (2024) |
Commercial Beverage Coolers - Classification, Requirements and Test Conditions (Third Revision) |
Commercial Beverage Coolers |
198000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-5.1(Classification according to temperature) |
- |
500 |
|
- |
Cl-5.2.1.1(Strength and rigidity) |
- |
1000 |
|
- |
Cl-5.2.1.2(Pipes and connections) |
- |
1000 |
|
- |
Cl-5.2.2(Materials) |
- |
1000 |
|
- |
Cl-5.2.3(Thermal insulation) |
- |
1000 |
|
- |
Cl-5.2.4(Refrigerating system) |
- |
1000 |
|
- |
Cl-5.2.5(Electrical components) |
- |
1000 |
|
- |
Cl-6.2.1(General) |
- |
0 |
|
- |
Cl-6.2.2(Seal test for doors and lids) |
- |
5000 |
|
- |
Cl-6.2.3(Test on durability of door and lid.) |
- |
50000 |
|
- |
Cl-6.2.4(Linear dimensions, areas and volumes) |
- |
1000 |
|
- |
Cl-6.3.2(Test room condition) |
- |
0 |
|
- |
Cl-6.3.3(M-can) |
- |
0 |
|
- |
Cl-6.3.4(Preparation of test commercial beverage cooler and general test procedures) |
- |
10000 |
|
- |
Cl-6.3.5(Loading the commercial beverage cooler) |
- |
10000 |
|
- |
Cl-6.3.6(Running in period) |
- |
5000 |
|
- |
Cl-6.3.7(Stable conditions) |
- |
10000 |
|
- |
Cl-6.3.8(Lighting and night-covers) |
- |
1000 |
|
- |
Cl-6.3.9(Power supply) |
- |
1000 |
|
- |
Cl-6.3.10(Testing several commercial beverage coolers in the same room) |
- |
0 |
|
- |
Cl-6.3.11(Test with M-cans) |
- |
40000 |
|
- |
Cl-6.3.12(Water vapour condensation test) |
- |
38000 |
|
- |
Cl-6.3.13(Calculation of specific energy consumption (SEC).) |
- |
5000 |
|
- |
Cl-6.3.14(Lighting test) |
- |
5000 |
|
- |
Cl-6.4(Test report) |
- |
5000 |
|
- |
Cl-7(Marking) |
- |
2000 |
|
- |
|
19 Mar, 2026 |
- Included w.e.f 29.07.2025 |
5 |
IS 17550 : PART 3 (2021) |
Household Refrigerating Appliance- Characteristics and test methods Part 3 Energy Consumption and volume |
Household Refrigerating Appliances |
125000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
"Cl. No. 6 "("DETERMINATION OF ENERGY
CONSUMPTION") |
- |
20500 |
|
- |
"Cl. No.4.8 & Annex H "(Determination Of Volume) |
- |
5500 |
|
- |
"Cl. No. 6 "("DETERMINATION OF ENERGY
CONSUMPTION") |
- |
2050020 |
|
- |
"Cl. No. 6 "("DETERMINATION OF ENERGY
CONSUMPTION") |
- |
20500 |
|
- |
"Cl. No.4.8 & Annex H "(Determination Of Volume) |
- |
5500 |
|
- |
4.2(Steady State Power Consumption) |
- |
20000 |
|
- |
4.3(Defrost and Recovery Energy and temperature change) |
- |
20000 |
|
- |
4.4(Defrost Frequency) |
- |
20000 |
|
- |
4.5(Number of Test Points and Interpolations) |
- |
10000 |
|
- |
4.6(Load Processing Efficiency) |
- |
17000 |
|
- |
4.7(Specified Auxiliaries) |
- |
12000 |
|
- |
4.8(Volumn Determination) |
- |
5500 |
|
- |
6(Determination of Energy Consumption) |
- |
20500 |
|
- |
Annex B(Determination of Steady state Power & Temperature) |
- |
20000 |
|
- |
Annex C(Defrost and Recovery Energy and temperature change) |
- |
20000 |
|
- |
Annex D(Defrost Interval) |
- |
20000 |
|
- |
Annex E(Interpolation of Results) |
- |
10000 |
|
- |
Annex F(Energy Consumption of specified auxiliaries) |
- |
12000 |
|
- |
Annex G(Determination of Load Processing Efficiency) |
- |
17000 |
|
- |
Annex H(Determination of Volume) |
- |
5500 |
|
- |
|
19 Mar, 2026 |
- - |
6 |
IS 17550 : PART 2 (2021) |
Household Refrigerating Appliance- Characteristics and test methods Part 2 Performance requirements |
Household Refrigerating Appliances |
325000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. No. 6(Storage Test) |
- |
54000 |
|
- |
Cl. No. 7(Cooling Capacity Test) |
- |
39000 |
|
- |
Cl. No. 8(Freezing Capacity Test) |
- |
39000 |
|
- |
Cl. No. 9("Automatic Ice-Making
Capacity Test") |
- |
38000 |
|
- |
"Cl. No.4.6 & Annex A"(PULL-DOWN TEST) |
- |
40000 |
|
- |
Cl. No.4.6(b) & Annex B("Wine Storage
Appliances And
Compartments;
Storage Test") |
- |
38000 |
|
- |
Cl. No.4.6(C) & AnnexC("Temperature Rise
Test ") |
- |
39000 |
|
- |
Cl. No.4.6(d) & Annex D("Water Vapour Condensation
Test ") |
- |
38000 |
|
- |
Cl. No.4.6(d) & Annex D("Water Vapour Condensation
Test ") |
- |
38000 |
|
- |
Cl. No. 6(Storage Test) |
- |
54000 |
|
- |
Cl. No. 8(Freezing Capacity Test) |
- |
39000 |
|
- |
Cl. No. 9("Automatic Ice-Making
Capacity Test") |
- |
38000 |
|
- |
"Cl. No.4.6 & Annex A"(PULL-DOWN TEST) |
- |
40000 |
|
- |
Cl. No.4.6(b) & Annex B("Wine Storage
Appliances And
Compartments;
Storage Test") |
- |
38000 |
|
- |
Cl. No.4.6(C) & AnnexC("Temperature Rise
Test ") |
- |
39000 |
|
- |
Cl. No.4.6(d) & Annex D("Water Vapour Condensation
Test ") |
- |
38000 |
|
- |
4.2(Storage test) |
- |
54000 |
|
- |
4.3(Cooling capacity test) |
- |
39000 |
|
- |
4.5(Automatic ice-making capacity test) |
- |
38000 |
|
- |
4.6(Other Tests) |
- |
54000 |
|
- |
6(Storage test) |
- |
54000 |
|
- |
7(Cooling capacity test) |
- |
39000 |
|
- |
8(Freezing capacity test) |
- |
39000 |
|
- |
9(Automatic ice-making capacity test) |
- |
38000 |
|
- |
Annex A(Pull Down test) |
- |
40000 |
|
- |
Annex B(Storage test of wine storage appliances and compartments) |
- |
38000 |
|
- |
Annex C(Temperature Rise Test) |
- |
39000 |
|
- |
Annex D(Water Vapour Condensation Test) |
- |
38000 |
|
- |
4.4(Freezing Capacity Test) |
- |
39000 |
|
- |
5(General Test Conditions) |
- |
0 |
|
- |
|
19 Mar, 2026 |
- - |
7 |
IS 17550 : PART 1 (2021) |
HOUSEHOLD REFRIGERATING APPLIANCES CHARACTERISTICS AND TEST METHODS Part 1 General Requirements |
Household Refrigerating Appliances |
215000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
"Cl. No. 9 "(Testing The Air Tightness Of Door Or Lid Seal(S)) |
- |
5000 |
|
- |
"Cl. No.10 "(Testing The Opening Force Of Door(S) Or Lid(S)) |
- |
8000 |
|
- |
"Cl. No.11 "(Testing The Durability Of Hinges And Handles Of Door(S) And Lid(S)) |
- |
50000 |
|
- |
"Cl. No.12 "(Testing The Mechanical Strength Of Shelves And Similar Components) |
- |
12000 |
|
- |
"Cl. No.14 "(Ice-Making Test (If Applicable)) |
- |
30000 |
|
- |
"Cl. No.15 "(Test For Absence Of Odour And Taste) |
- |
50000 |
|
- |
"Cl. No.16 "(Safety Requirements) |
- |
43000 |
|
- |
"Cl. No. 9 "(Testing The Air Tightness Of Door Or Lid Seal(S)) |
- |
5000 |
|
- |
"Cl. No.10 "(Testing The Opening Force Of Door(S) Or Lid(S)) |
- |
8000 |
|
- |
"Cl. No.11 "(Testing The Durability Of Hinges And Handles Of Door(S) And Lid(S)) |
- |
50000 |
|
- |
"Cl. No.12 "(Testing The Mechanical Strength Of Shelves And Similar Components) |
- |
12000 |
|
- |
"Cl. No.14 "(Ice-Making Test (If Applicable)) |
- |
30000 |
|
- |
"Cl. No.15 "(Test For Absence Of Odour And Taste) |
- |
50000 |
|
- |
"Cl. No.16(a) "(Protection against acess to live parts) |
- |
5000 |
|
- |
"Cl. No.16(b) "(Power input and current) |
- |
10000 |
|
- |
"Cl. No.16(c) "(Heating) |
- |
10000 |
|
- |
"Cl. No.16(d) "(Leakage current and electric strength at operating temperature) |
- |
4000 |
|
- |
"Cl. No.16(e) "(Moisture resistance) |
- |
10000 |
|
- |
"Cl. No.16(f) "(Leakage current and electric strength) |
- |
4000 |
|
- |
"Cl. No.20.3(a) "("Production Routine Test
a)Leakage current test
") |
- |
4000 |
|
- |
"Cl. No.20.3(b) "(b) Earth continuity tesT) |
- |
4000 |
|
- |
"Cl. No.20.3(c) "(c) Electric strength) |
- |
4000 |
|
- |
"Cl. No.8.11 "(Thermostat function test) |
- |
500 |
|
- |
"Cl. No.5 "(Markings) |
- |
1000 |
|
- |
4(Classification) |
- |
100 |
|
- |
5(Marking) |
- |
1000 |
|
- |
6.2(Determination of Linear Dimensions) |
- |
500 |
|
- |
7(Instructions) |
- |
100 |
|
- |
8.2(Material and Finishes) |
- |
500 |
|
- |
8.3(Thermal Insulation and Air Tightness) |
- |
0 |
|
- |
8.4(Doors, Lids and Fittings) |
- |
0 |
|
- |
8.5(Shelves and Containers) |
- |
500 |
|
- |
8.6(Disposal of Defrost Water) |
- |
500 |
|
- |
8.7(Refrigerating System) |
- |
500 |
|
- |
8.8(Supply Cord) |
- |
500 |
|
- |
8.9(Compressor) |
- |
0 |
|
- |
8.10(Temperature Sensing Controls (Thermostat)) |
- |
0 |
|
- |
8.11(Temperature Sensing Controls (Thermostat) Setting) |
- |
500 |
|
- |
9(Testing the Air tightness of door or lid seal(s) before water vapour condensation test) |
- |
5000 |
|
- |
9(Testing the Air tightness of door or lid seal(s) after water vapour condensation test) |
- |
5000 |
|
- |
10(Testing the Opening force of door(s) or lid(s)) |
- |
8000 |
|
- |
11(Testing the Durability of hinges and handles of door(s) and lid(s)) |
- |
50000 |
|
- |
12(Testing the Mechanical strength of shelves and similar components) |
- |
12000 |
|
- |
13(Water-vapour condensation test) |
- |
38000 |
|
- |
14(Ice-making test (if applicable)) |
- |
30000 |
|
- |
15(Test for absence of odour and taste) |
- |
50000 |
|
- |
16(a)(Protection against access to live parts) |
- |
5000 |
|
- |
16(b)(Power input and current) |
- |
10000 |
|
- |
16 (c(Heating) |
- |
10000 |
|
- |
16(d)(Leakage current and electric strength at operating temperature) |
- |
4000 |
|
- |
16(e)(Moisture resistance) |
- |
10000 |
|
- |
16(f)(Leakage current and electric strength (high voltage after humidity)) |
- |
4000 |
|
- |
17(Packing) |
- |
100 |
|
- |
18(Designation) |
- |
100 |
|
- |
19(Instructions for Use and Maintenance) |
- |
100 |
|
- |
20.3 (a)(Leakage Current Test) |
- |
4000 |
|
- |
20.3 (b)(Earth Continuity Test) |
- |
4000 |
|
- |
20.3 (c(Electric Strength Test) |
- |
4000 |
|
- |
|
19 Mar, 2026 |
- - |
8 |
IS 17550 : Part 1 (2024) |
Household Refrigerating Appliances - Characteristics and Test Methods Part 1 General Requirements (First Revision) |
Household Refrigerating Appliances |
215000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(MARKING) |
- |
1000 |
|
- |
8(MATERIALS, DESIGN, AND MANUFACTURE) |
- |
3000 |
|
- |
9(Testing The Air Tightness Of Door Or Lid Seal(S)) |
- |
5000 |
|
- |
10(Testing The Opening Force Of Door(S) Or Lid(S)) |
- |
8000 |
|
- |
11(Testing The Durability Of Hinges And Handles Of Door(S) And Lid(S) |
- |
50000 |
|
- |
12(Testing The Mechanical Strength Of Shelves And Similar Components) |
- |
12000 |
|
- |
14(Ice-Making Test (If Applicable)) |
- |
30000 |
|
- |
15(Test For Absence Of Odour And Taste) |
- |
50000 |
|
- |
16(Safety Requirements) |
- |
43000 |
|
- |
|
19 Mar, 2026 |
- - |
9 |
IS 17550 : Part 2 (2024) |
Household Refrigerating Appliances - Characteristics and Test Methods Part 2 Performance Requirements (First Revision) |
Household Refrigerating Appliances |
325000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Storage Test) |
- |
54000 |
|
- |
7(Cooling Capacity Test) |
- |
39000 |
|
- |
8(Freezing Capacity Test) |
- |
39000 |
|
- |
9("Automatic Ice-Making
Capacity Test") |
- |
38000 |
|
- |
Cl. No.4.6 & Annex A(PULL-DOWN TEST) |
- |
40000 |
|
- |
Cl. No.4.6(b) & Annex B("Wine Storage
Appliances And
Compartments;
Storage Test") |
- |
38000 |
|
- |
Cl. No.4.6(C) & AnnexC("Temperature Rise
Test ") |
- |
39000 |
|
- |
Cl. No.4.6(d) & Annex D("Water Vapour Condensation
Test ") |
- |
38000 |
|
- |
|
19 Mar, 2026 |
- - |
10 |
IS 18801 (2023) |
Refrigerated storage cabinets and counters for professional use Performance and energy consumption |
Refrigerated Storage Cabinets and Counters for professional use |
273000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-4.1(Condensate drainage) |
- |
0 |
|
- |
Cl-4.2.1(Classification according to temperature) |
- |
0 |
|
- |
Cl-4.2.2(Defrosting) |
- |
0 |
|
- |
Cl-4.2.3(Electrical energy consumption) |
- |
0 |
|
- |
Cl-5.1(General) |
- |
0 |
|
- |
Cl-5.2(Tests outside test room) |
- |
0 |
|
- |
Cl-5.3.2(Tests inside test room- Test conditions) |
- |
0 |
|
- |
Cl-5.3.3(Tests inside test room- Preparation of test cabinet) |
- |
0 |
|
- |
Cl-5.3.4(Tests inside test room- Temperature test) |
- |
60000 |
|
- |
Cl-5.3.5(Tests inside test room- Electrical energy consumption test.) |
- |
175000 |
|
- |
Cl-6.1(Calculation of net volume.) |
- |
5000 |
|
- |
Cl-6.2(Load line and cabinet label marking durability) |
- |
500 |
|
- |
Cl-6.3(Tests outside test room — Linear dimensions, areas and volumes) |
- |
5000 |
|
- |
Cl-4.1(Condensate drainage) |
- |
- |
|
- |
Cl-4.2.1(Classification according to temperature) |
- |
- |
|
- |
Cl-4.2.2(Defrosting) |
- |
- |
|
- |
Cl-4.2.3(Electrical energy consumption) |
- |
- |
|
- |
Cl-5.1(General) |
- |
- |
|
- |
Cl-5.2(Tests outside test room) |
- |
- |
|
- |
Cl-5.3.2(Tests inside test room- Test conditions) |
- |
- |
|
- |
Cl-5.3.3(Tests inside test room- Preparation of test cabinet) |
- |
- |
|
- |
Cl-5.3.4(Tests inside test room- Temperature test) |
- |
- |
|
- |
Cl-5.3.5(Tests inside test room- Electrical energy consumption test.) |
- |
- |
|
- |
Cl-6.1(Calculation of net volume.) |
- |
- |
|
- |
Cl-6.2(Load line and cabinet label marking durability) |
- |
- |
|
- |
Cl-6.3(Tests outside test room — Linear dimensions, areas and volumes) |
- |
- |
|
- |
|
19 Mar, 2026 |
- - |
11 |
IS 18802 (2023) |
Blast chiller and freezer cabinets for professional use Classification requirements and test conditions |
Blast Chiller and Freezer Cabinets for Professional use --- Classification, Requirements and Test Conditions |
240000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-4.1(Reference temperature and time of test food) |
- |
0 |
|
Nil |
Cl-4.2(Test time) |
- |
0 |
|
Nil |
Cl-5.1(Test room) |
- |
0 |
|
Nil |
Cl-5.2(Blast cabinet selection, installation and positioning within the test room) |
- |
0 |
|
Nil |
Cl-5.3(Blast cabinet operation) |
- |
0 |
|
Nil |
Cl-5.4(Power supply) |
- |
0 |
|
Nil |
Cl-5.5(Instruments, measuring equipment and measuring accuracy) |
- |
0 |
|
Nil |
Cl-5.6.1(Test food) |
- |
150000 |
|
Nil |
Cl-5.6.2(Test pan loading) |
- |
0 |
|
Nil |
Cl-5.6.3(M-pans) |
- |
0 |
|
Nil |
Cl-5.6.4(Blast cabinet loading) |
- |
0 |
|
Nil |
Cl-5.7(Temperature recording) |
- |
0 |
|
Nil |
Cl-6(Test procedure for total energy measurement) |
- |
90000 |
|
Nil |
|
19 Mar, 2026 |
- - |
12 |
IS/IEC 61730 : PART 2 (2016) |
Photovoltaic (PV) module safety qualification: Part 2 requirements for testing (First Revision) |
Photovoltaic (PV) Module |
847500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 10.2(Visual inspection MST 01) |
- |
7500 |
|
- |
Clause 10.3(Performance at STC MST 02) |
- |
7500 |
|
- |
Clause 10.4(Maximum powerdetermination MST 03) |
- |
12500 |
|
- |
Clause 10.5(Insulation thickness test MST 04) |
- |
15000 |
|
- |
Clause 10.6(Durability of markings MST 05) |
- |
15000 |
|
- |
Clause 10.7(Sharp edge test MST 06) |
- |
15000 |
|
- |
Clause 10.8(Bypass diode functionality test MST 07) |
- |
15000 |
|
- |
Clause 10.9(Accessibility test MST 11) |
- |
15000 |
|
- |
Clause 10.10(Cut susceptibility test MST 12) |
- |
15000 |
|
- |
Clause 10.11(Continuity test of equipotential bonding MST 13) |
- |
20000 |
|
- |
Clause 10.12(Impulse voltage test MST 14) |
- |
22500 |
|
- |
Clause 10.13(Insulation test MST 16) |
- |
25000 |
|
- |
Clause 10.14(Wet leakage current test MST 17) |
- |
15000 |
|
- |
Clause 10.15(Temperature test MST 21) |
- |
45000 |
|
- |
Clause 10.16(Hot-spot endurance test MST 22) |
- |
22500 |
|
- |
Clause 10.17(Fire test MST 23) |
- |
175000 |
|
- |
Clause 10.18(Ignitability test MST 24) |
- |
12500 |
|
- |
Clause 10.19(Bypass diode thermal test MST 25) |
- |
12500 |
|
- |
Clause 10.20(Reverse current overload test MST 26) |
- |
55000 |
|
- |
Clause 10.21(Module breakage test MST 32) |
- |
27500 |
|
- |
Clause 10.22(Screw connections test MST 33) |
- |
32500 |
|
- |
Clause 10.23(Static mechanical load test MST 34) |
- |
12500 |
|
- |
Clause 10.24(Peel test MST 35) |
- |
12500 |
|
- |
Clause 10.25(Lap shear strength test MST 36) |
- |
5000 |
|
- |
Clause 10.26(Materials creep test MST 37) |
- |
12500 |
|
- |
Clause 10.27(Robustness of terminations test MST 42) |
- |
12500 |
|
- |
Clause 10.28(Thermal cycling test MST 51) |
- |
17500 |
|
- |
Clause 10.29(Humidity freeze test MST 52) |
- |
55000 |
|
- |
Clause 10.30(Damp heat test MST 53) |
- |
40000 |
|
- |
Clause 10.31(UV test MST 54) |
- |
27500 |
|
- |
Clause 10.32(Cold conditioning MST 55) |
- |
40000 |
|
- |
Clause 10.33(Dry heat conditioning MST 56) |
- |
30000 |
|
- |
|
19 Mar, 2026 |
- - |
13 |
IS 8448 (1989) |
Automatic line voltage correctors (Step Type) for domestic use - Specification (First Revision) |
Automatic line voltage correctors (Step Type) for domestic use |
54000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(Cooling) |
- |
0 |
|
- |
5.1(RATINGS : Rated kVA
) |
- |
100 |
|
- |
5.2.1(Rated Voltage : Input Voltage Range
) |
- |
100 |
|
- |
5.2.2(Rated Voltage : Output Voltage Range) |
- |
100 |
|
- |
6.1(CONSTRUCTION) |
- |
150 |
|
- |
6.2(CONSTRUCTION) |
- |
150 |
|
- |
6.3(CONSTRUCTION) |
- |
150 |
|
- |
6.4(CONSTRUCTION) |
- |
150 |
|
- |
6.5(CONSTRUCTION) |
- |
150 |
|
- |
6.6(CONSTRUCTION) |
- |
150 |
|
- |
6.7(CONSTRUCTION) |
- |
150 |
|
- |
8 of IS 302:1979( SAFETY REQUIREMENTS : Protection Against Electric Shock) |
- |
22500 |
|
- |
13.2 of IS 302:1979( SAFETY REQUIREMENTS : Leakage Current) |
- |
22500 |
|
- |
20.1 of IS 302:1979( SAFETY REQUIREMENTS : Stability ) |
- |
22500 |
|
- |
21 of IS 302:1979( SAFETY REQUIREMENTS : Mechanical Strength) |
- |
22500 |
|
- |
27 of IS 302:1979( SAFETY REQUIREMENTS : Provision for Earthing ) |
- |
22500 |
|
- |
28 of IS 302:1979( SAFETY REQUIREMENTS : Screws and Connections ) |
- |
22500 |
|
- |
29 of IS 302:1979( SAFETY REQUIREMENTS : Clearances ) |
- |
22500 |
|
- |
8.1(LIMITS OF TEMPERATURE-RISE ) |
- |
0 |
|
- |
8.2(LIMITS OF TEMPERATURE-RISE ) |
- |
0 |
|
- |
9.1( PERFORMANCE-REQUIREMENTS ) |
- |
2500 |
|
- |
10.1(TERMINAL MARKING ) |
- |
150 |
|
- |
11.1( MARKING : Rating Plate ) |
- |
100 |
|
- |
11.1( MARKING : Manufacturer’s name and country of manufacture) |
- |
100 |
|
- |
11.1( MARKING : Manufacturer’s serial number land type number) |
- |
100 |
|
- |
11.1( MARKING : Rated input voltage range) |
- |
100 |
|
- |
11.1( MARKING :Rated output voltage) |
- |
100 |
|
- |
11.1( MARKING : Rated frequency ) |
- |
100 |
|
- |
11.1( MARKING : Rated output current) |
- |
100 |
|
- |
11.1( MARKING : Rated kVA) |
- |
100 |
|
- |
11.1( MARKING : Class of insulation.) |
- |
100 |
|
- |
12.2(TESTS : Physical examination) |
- |
150 |
|
- |
12.3(TESTS : Output voltage ) |
- |
2500 |
|
- |
12.4(TESTS : Insulation resistance) |
- |
2500 |
|
- |
12.5(TESTS : High voltage) |
- |
2500 |
|
- |
12.6(TESTS : No-load current) |
- |
5000 |
|
- |
7.1(TESTS : Protection against electric shock) |
- |
22500 |
|
- |
7.3(TESTS : Stability ) |
- |
22500 |
|
- |
7.4(TESTS : Mechanical strength ) |
- |
22500 |
|
- |
7.5(TESTS : Provision for earthing ) |
- |
22500 |
|
- |
7.6(TESTS : Screws and connections ) |
- |
22500 |
|
- |
12.7.1( Temperature-rise : Measurment of Temperature of colling Air) |
- |
22500 |
|
- |
12.7.2(Temperature-rise : Determination of Winding Temperature ) |
- |
22500 |
|
- |
12.7.3(Temperature-rise : Duration of Test of Temperature Rise ) |
- |
22500 |
|
- |
12.7.4(Temperature-rise : Leading) |
- |
22500 |
|
- |
12.7(Temperature-rise : Temperature Correction for Cooling of Transformer after Shut Down ) |
- |
22500 |
|
- |
7.2(TESTS : Leakage current ) |
- |
22500 |
|
- |
7.7(TESTS : Creepage distances ) |
- |
22500 |
|
- |
7.7(TESTS : clearances ) |
- |
22500 |
|
- |
12.8(TESTS : Induced voltage ) |
- |
22500 |
|
- |
12.9(TESTS : Damp heat ) |
- |
12500 |
|
- |
12.1(TESTS : Stability test for relay operation) |
- |
5500 |
|
- |
12.11(TESTS : Test for continuous operation ) |
- |
12500 |
|
- |
Clause 4(Cooling) |
- |
0 |
|
- |
Clause 5(Rating) |
- |
100 |
|
- |
Clause 6(Construction) |
- |
150 |
|
- |
Clause 7.1(Protection Against
Electric Shock) |
- |
22500 |
|
- |
Clause 7.2(Leakage Current) |
- |
22500 |
|
- |
Clause 7.3(Stability) |
- |
22500 |
|
- |
Clause 7.4(Mechanical Strength) |
- |
22500 |
|
- |
Clause 7.5(Provision for Earthing) |
- |
22500 |
|
- |
Clause 7.6(Screws and Connections) |
- |
22500 |
|
- |
Clause 7.7(Creepage Distances
and Clearances) |
- |
22500 |
|
- |
Clause 8(Limits Of Temperature
rise) |
- |
7500 |
|
- |
Clause 9(Performance Requirement) |
- |
5000 |
|
- |
Clause 10(Terminal Marking) |
- |
150 |
|
- |
Clause 11(Marking) |
- |
100 |
|
- |
Clause 12.1(Classification of Tests) |
- |
0 |
|
- |
Clause 12.2(Physical Examination) |
- |
150 |
|
- |
Clause 12.3(Output Voltage Test) |
- |
2500 |
|
- |
Clause 12.4(Insulation Resistance
Test) |
- |
2500 |
|
- |
Clause 12.5(High Voltage Test) |
- |
2500 |
|
- |
Clause 12.6(No Load Current Test) |
- |
5000 |
|
- |
Clause 12.7(Temperature-Rise Test) |
- |
7500 |
|
- |
Clause 12.8(Induced Voltage Test) |
- |
5000 |
|
- |
Clause 12.9(Damp Heat Test) |
- |
12500 |
|
- |
Clause 12.10(Stability Test for
Relay Operation) |
- |
5500 |
|
- |
29 of IS 302:1979( SAFETY REQUIREMENTS : Creepage Distances) |
- |
500 |
|
- |
Clause 12.11(Test for Continuous
Operation) |
- |
12500 |
|
- |
|
19 Mar, 2026 |
- Included w.e.f 28.04.2025 |
14 |
IS 16543 (2024) |
All-glass evacuated solar collector tubes - Specification (First revision) |
All-Glass Evacuated Solar Collector Tubes |
14100 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 4.1(Structure of All-Glass Evacuated Solar Collector Tube) |
- |
1000 |
|
- |
Cl 4.2 & table 1(Outer Diameter of Cover Glass Tube) |
- |
1000 |
|
- |
Cl 4.2 & table 1(Outer Diameter of Inner Glass Tube Including Coating) |
- |
1000 |
|
- |
Cl 4.2 & table 1(The Thickness of Cover and Inner Glass Tube) |
- |
1000 |
|
- |
Cl 4.2 & table 1(Tube Length) |
- |
1000 |
|
- |
Cl 4.2 & table 1(Sealed off Part Length) |
- |
1000 |
|
- |
Cl 4.3(Absorber Area for Different Tube Sizes) |
- |
1000 |
|
- |
Cl 4.4(Solar Selective Absorbing Coating) |
- |
1000 |
|
- |
Cl 4.5(Calculation for Number of Tubes for The Heating System) |
- |
1000 |
|
- |
Cl 5.1.1(Transmittance ratio ( material)) |
- |
1000 |
|
- |
Cl 5.1.2(Bubble & crack (material)) |
- |
1000 |
|
- |
Cl 5.1.3(Knots (material)) |
- |
1000 |
|
- |
Cl 5.1.4(Solar absorbing ratio (material)) |
- |
1000 |
|
- |
Cl 5.2.1(Scratch length and visibility) |
- |
1000 |
|
- |
Cl 5.2.2(Appearance of selective coating) |
- |
1000 |
|
- |
Cl 5.2.3(Colour fading area) |
- |
1000 |
|
- |
Cl 5.2.4(Strut member) |
- |
1000 |
|
- |
Cl 5.2.5(The inner and cover tube at the open end) |
- |
1000 |
|
- |
Cl 5.2.6(Length of an all-glass evacuated solar collector tube) |
- |
1000 |
|
- |
Cl 5.2.7(Bending of the all-glass evacuated solar collector tube) |
- |
1000 |
|
- |
Cl 5.2.8(Cross-section of the open end) |
- |
1000 |
|
- |
Cl 5.2.9(Sealed end) |
- |
1000 |
|
- |
Cl 7.2.2(Uniformity) |
- |
1000 |
|
- |
Cl 7.4(Stagnation Performance Parameter Test) |
- |
1000 |
|
- |
Cl 7.5(Stagnation Solar Irradiation Test) |
- |
1000 |
|
- |
Cl 7.6(Average Heat Loss Coefficient Test) |
- |
2000 |
|
- |
Cl 7.7(Vacuum Performance Test) |
- |
1000 |
|
- |
Cl 7.8(Resistance to Thermal Shock Test) |
- |
1000 |
|
- |
Cl 7.9(Resistance to Impact Test) |
- |
1000 |
|
- |
Cl 7.10(0 Resistance to Internal Pressure Test) |
- |
1000 |
|
- |
Cl 7.11(Absorptivity and Emissivity Test of the Selective Coating) |
- |
2000 |
|
- |
Cl 9(Marking) |
- |
50 |
|
- |
|
19 Mar, 2026 |
- Included w.e.f 02.06.2025 |
15 |
IS 12933 : Part 2 (2003) |
Solar flat plate collector - Specification: Part 2 components (Second Revision) |
Solar Flat Plate Collector |
4400 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12.1.1(Thermal Shock Test) |
- |
500 |
|
- |
11(MATERIALS) |
- |
500 |
|
- |
10(BACK AND SIDE INSULATION) |
- |
500 |
|
- |
9.2.2(Bonding Between Riser and Sheet) |
- |
500 |
|
- |
9.2.1(Static Pressure Leakage Test) |
- |
500 |
|
- |
9.1.4(Temperature Test) |
- |
500 |
|
- |
8(FABRICATION) |
- |
500 |
|
- |
7(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
5.1(Transmittance Test) |
- |
500 |
|
- |
|
19 Mar, 2026 |
- Included w.e.f 02.06.2025 |
16 |
IS 12933 : Part 1 (2003) |
Solar flat plate collector - Specification: Part 1 requirements (Second Revision) |
Solar Flat Plate Collector |
32500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Components: The various components of solar flat plate collector shall be as specified in IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Components: The various components of solar flat plate collector shall be as specified in IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Components: The various components of solar flat plate collector shall be as specified in IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Components: The various components of solar flat plate collector shall be as specified in IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Components: The various components of solar flat plate collector shall be as specified in IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Components: The various components of solar flat plate collector shall be as specified in IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Components: The various components of solar flat plate collector shall be as specified in IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Components: The various components of solar flat plate collector shall be as specified in IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Components: The various components of solar flat plate collector shall be as specified in IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Components: The various components of solar flat plate collector shall be as specified in IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Components: The various components of solar flat plate collector shall be as specified in IS 12933 (Part 2)) |
- |
1500 |
|
- |
7.1.1(Static Pressure Leakage Test) |
- |
1000 |
|
- |
7.2.1(Outdoor No Flow Exposure Test ) |
- |
2000 |
|
- |
7.2.2(External Thermal Shock Test ) |
- |
2000 |
|
- |
7.2.2(Internal Thermal Shock Test ) |
- |
2000 |
|
- |
7.2.4(Rain Penetration Test) |
- |
2000 |
|
- |
7.2.5(Impact Resistance Test) |
- |
1000 |
|
- |
7.2.6(Thermal Efficiency Test) |
- |
15000 |
|
- |
7.2.7(Determination of the Time Constant ) |
- |
2500 |
|
- |
7.2.8(Incident Angle Modifier Test) |
- |
2500 |
|
- |
7.2.8(Incident Angle Modifier Test) |
- |
2500 |
|
- |
4(Cover Plate, Material ( Cl. 4 of IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Cover Plate, Material ( Cl. 4 of IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Cover Plate, Material ( Cl. 4 of IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Collector box, Material (Cl.6.1 of IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Collector box, i) Aluminium: a) Channel section for sides (Cl.6.2 of IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Collector box, i) Aluminium: b) Sheet for bottom (Cl.6.2 of IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Collector box, i) Aluminium: c) Support for glass retaining, (Cl.6.2 of IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Collector box, i) Aluminium: d) Sheet for entire body(Cl.6.2 of IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Collector box,ii) Fibre glass (Cl.6.2 of IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Collector box, iii) Galvanized/stainless steel sheet (Cl.6.2 of IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Collector box, iv) CRCA/HRC (Cl.6.2 of IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Absorber (Cl.9.1.3 of IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Absorber -Temperature test (Cl.9.1.4 of IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Riser and Headers- Static Pressure Leakage Test ( Cl. 9.2.1 of IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Bonding Between Riser and Sheet ( Cl. 9.2.2.1 of IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Bonding Between Riser and Sheet ( Cl. 9.2.2.2 of IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Collector Box Insulation- Back and Side Insulation ( Cl. 10.1 of IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Collector Box Insulation- Back and Side Insulation ( Cl. 10.2 of IS 12933 (Part 2)) |
- |
1500 |
|
- |
4(Workmanship and Finish (Cl.7.1 of IS 12933 (Part 2)) |
- |
50 |
|
- |
4(Gaskets and Grommets- Materials ( Cl. 11.1 of IS 12933 (Part 2)) |
- |
50 |
|
- |
4(Gaskets and Grommets- Materials ( Cl.11.2 of IS 12933 (Part 2)) |
- |
50 |
|
- |
4(Thermal shock Test -Gaskets and Grommets (Cl.12.1 of IS 12933 (Part 2)) |
- |
50 |
|
- |
5(Shape and Dimensions) |
- |
500 |
|
- |
6.1(Assembley and Workmanship) |
- |
350 |
|
- |
6.2(Assembley and Workmanship) |
- |
350 |
|
- |
6.3(Assembley and Workmanship) |
- |
350 |
|
- |
6.4(Assembley and Workmanship) |
- |
350 |
|
- |
4(Workmanship and Finish, b) Electroplated zinc coating (Cl.7.2 of IS 12933 (Part 2)) |
- |
50 |
|
- |
4(Workmanship and Finish, b) Electroplated zinc coating (Cl.7.2 of IS 12933 (Part 2)) |
- |
50 |
|
- |
4(Workmanship and Finish, c) Powder coating (Cl.7.2 of IS 12933 (Part 2)) |
- |
50 |
|
- |
4(Workmanship and Finish, c) Powder coating (Cl.7.2 of IS 12933 (Part 2)) |
- |
50 |
|
- |
4(Fabrication - Aluminium Box (Cl.8.1 of IS 12933 (Part 2)) |
- |
50 |
|
- |
4(Fabrication - Fibre glass boxes (Cl.8.2 of IS 12933 (Part 2)) |
- |
50 |
|
- |
4(Fabrication- Al/CRCA/HRC//Galvanised steel /any other material (Cl.8.3 of IS 12933 (Part 2)) |
- |
50 |
|
- |
4(Absorber (Cl.9.1 of IS 12933 (Part 2)) |
- |
50 |
|
- |
4(Absorber (Cl.9.1.1 of IS 12933 (Part 2)) |
- |
50 |
|
- |
4(Absorber (Cl.9.1.2 of IS 12933 (Part 2)) |
- |
50 |
|
- |
5(SHAPE AND DIMENSIONS) |
- |
500 |
|
- |
|
19 Mar, 2026 |
- Included w.e.f 02.06.2025 |
17 |
IS 16542 (2016) |
Direct insertion type storage water tank for all glass evacuated tubes solar collector - Specification |
Direct insertion type storage water tank for all glass evacuated tubes solar collector |
9500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.3(Ideal Heating Test) |
- |
2000 |
|
- |
8.2(Leakage Test) |
- |
500 |
|
- |
8.4(Integral Test) |
- |
2000 |
|
- |
8.5(Performance Test) |
- |
2000 |
|
- |
7.6(Thermal Shock Test for Inner Sealing) |
- |
500 |
|
- |
7.7(Thermal Shock Test for outer Sealing) |
- |
500 |
|
- |
6(GENERAL REQUIREMENTS) |
- |
0 |
|
- |
8.1(Measurement of Storage Water Tank Capacity) |
- |
500 |
|
- |
|
19 Mar, 2026 |
- Included w.e.f 02.06.2025 |
18 |
IS 16544 (2016) |
All glass evacuated tubes solar water heating system |
All Glass Evacuated Tubes Solar Water Heating System |
74100 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1(Pre-Conditioning Test) |
- |
10000 |
|
- |
6.2.1 (Annex - B)(Exterior Test) |
- |
10000 |
|
- |
6.2.2 (Annex - C)(Leakage Test) |
- |
6000 |
|
- |
6.2.3 (Annex - D)(Stagnation Test) |
- |
6000 |
|
- |
6.2.4 (Annex - E)(External Thermal Shock Test) |
- |
6000 |
|
- |
6.2.5 (Annex - F)(Internal Thermal Shock Test) |
- |
10000 |
|
- |
6.2.6(Thermal Performance Test) |
- |
10000 |
|
- |
6.2.7() |
- |
10000 |
|
- |
5(General Requirements) |
- |
5000 |
|
- |
6.1(Pre-Conditioning Test) |
- |
0 |
|
- |
6.2.1 (Annex - B)(Exterior Test) |
- |
0 |
|
- |
6.2.2 (Annex - C)(Leakage Test) |
- |
0 |
|
- |
6.2.3 (Annex - D)(Stagnation Test) |
- |
0 |
|
- |
6.2.4 (Annex - E)(External Thermal Shock Test) |
- |
0 |
|
- |
6.2.5 (Annex - F)(Internal Thermal Shock Test) |
- |
0 |
|
- |
6.2.6(Thermal Performance Test) |
- |
0 |
|
- |
6.2.7() |
- |
0 |
|
- |
5(General Requirements) |
- |
0 |
|
- |
|
19 Mar, 2026 |
- Included w.e.f 02.06.2025 |
19 |
IS 9567 (2001) |
Tin or tin - Lead coated copper wire - Specificaiton (First Revision) |
Tin or Tin-lead Coated Copper Wire |
20000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.2(Resistivity) |
- |
5000 |
|
- |
4.4(Diameter of Coated Wire) |
- |
500 |
|
- |
5(Packing and Marking) |
- |
250 |
|
- |
6.3.1(Resistance Test) |
- |
5000 |
|
- |
6.4.1(Measurement of Diameter) |
- |
250 |
|
- |
6.4.2(Elongation and Breaking Strength Test) |
- |
7500 |
|
- |
6.4.3(Bend Test) |
- |
1500 |
|
- |
|
19 Mar, 2026 |
- Included w.e.f 28.04.2025
Excluding chemical tests |
20 |
IS 14286 : Part 1 (2023) |
Terrestrial Photovoltaic PV Modules Design Qualification and Type Approval Part 1: Test Requirements (Third Revision) |
Terrestrial Photovoltaic PV Modules |
1502500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(Visual inspection (MQT 01)) |
- |
7000 |
|
- |
4.2(Maximum power determination (MQT 02)) |
- |
7000 |
|
- |
4.3(Insulation test (MQT 03)) |
- |
20000 |
|
- |
4.4(Measurement of temperature coefficients (MQT 04)) |
- |
110000 |
|
- |
4.5(Placeholder section, formerly NMOT) |
- |
0 |
|
- |
4.6(Performance at STC (MQT 06.1)) |
- |
7500 |
|
- |
4.7(Performance at low irradiance (MQT 07)) |
- |
10000 |
|
- |
4.8(Outdoor exposure test (MQT 08)) |
- |
50000 |
|
- |
4.9(Hot-spot endurance test (MQT 09)) |
- |
125000 |
|
- |
4.10(UV preconditioning test (MQT 10)) |
- |
125000 |
|
- |
4.11(Thermal cycling test (MQT 11)) |
- |
160000 |
|
- |
4.12(2 Humidity-freeze test (MQT 12)) |
- |
80000 |
|
- |
4.13(Damp heat test (MQT 13)) |
- |
160000 |
|
- |
4.14(Robustness of terminations (MQT 14)) |
- |
15000 |
|
- |
4.15(5 Wet leakage current test (MQT 15)) |
- |
25000 |
|
- |
4.16(Static mechanical load test (MQT 16)) |
- |
50000 |
|
- |
4.17(Hail test (MQT 17)) |
- |
50000 |
|
- |
4.18(Bypass diode testing (MQT 18)) |
- |
75000 |
|
- |
4.19(Stabilization (MQT 19)) |
- |
95000 |
|
- |
4.20(Cyclic (dynamic) mechanical load test (MQT 20)) |
- |
95000 |
|
- |
4.21(Potential induced degradation test (MQT 21)) |
- |
175000 |
|
- |
4.22(Bending test (MQT 22)) |
- |
60000 |
|
- |
|
19 Mar, 2026 |
- Included w.e.f 05.03.2025 |
21 |
IS 1258 (2024) |
Bayonet lampholders (Fifth Revision) |
Bayonet lampholders |
14500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General requirements) |
- |
0 |
|
- |
6(Standard ratings) |
- |
50 |
|
- |
7(Classification) |
- |
50 |
|
- |
8(Marking) |
- |
100 |
|
- |
9(Dimensions) |
- |
200 |
|
- |
10(Protection against electric shock) |
- |
750 |
|
- |
11(Terminals) |
- |
500 |
|
- |
12(Provision for earthing) |
- |
750 |
|
- |
13(Construction) |
- |
500 |
|
- |
14(Switched lampholders) |
- |
1000 |
|
- |
15(Moisture resistance, insulation resistance and electrical strength) |
- |
1500 |
|
- |
16(Mechanical strength) |
- |
1250 |
|
- |
17(Screws, current-carrying parts and connections) |
- |
750 |
|
- |
18(Creepage distances and clearances) |
- |
600 |
|
- |
19(General resistance to heat) |
- |
1250 |
|
- |
20(Resistance to heat, fire and tracking) |
- |
2250 |
|
- |
21(Resistance to excessive residual stresses (season cracking) and to rusting) |
- |
3000 |
|
- |
Annex A(Season cracking/corrosion test) |
- |
500 |
|
- |
12.4(Thermal tests) |
- |
750 |
|
- |
9.1(Lampholder dimensions) |
- |
200 |
|
- |
11.2(Terminals) |
- |
500 |
|
- |
12.3(Provision for earthing) |
- |
750 |
|
- |
13.1(Construction) |
- |
500 |
|
- |
13.8(Construction) |
- |
500 |
|
- |
14.4(Switched lampholders) |
- |
1000 |
|
- |
15.1(Moisture resistance, insulation resistance and electrical strength) |
- |
1500 |
|
- |
16.7(Mechanical strength) |
- |
1250 |
|
- |
16.8(Mechanical strength) |
- |
1250 |
|
- |
21.2(Resistance to excessive residual stresses (season cracking) and to rusting) |
- |
3000 |
|
- |
4(General requirements) |
- |
0 |
|
- |
6(Standard ratings) |
- |
0 |
|
- |
7(Classification) |
- |
0 |
|
- |
8(Marking) |
- |
0 |
|
- |
9(Dimensions) |
- |
0 |
|
- |
10(Protection against electric shock) |
- |
0 |
|
- |
11(Terminals) |
- |
0 |
|
- |
12(Provision for earthing) |
- |
0 |
|
- |
13(Construction) |
- |
0 |
|
- |
14(Switched lampholders) |
- |
0 |
|
- |
15(Moisture resistance, insulation resistance and electrical strength) |
- |
0 |
|
- |
16(Mechanical strength) |
- |
0 |
|
- |
17(Screws, current-carrying parts and connections) |
- |
0 |
|
- |
18(Creepage distances and clearances) |
- |
0 |
|
- |
19(General resistance to heat) |
- |
0 |
|
- |
20(Resistance to heat, fire and tracking) |
- |
0 |
|
- |
21(Resistance to excessive residual stresses (season cracking) and to rusting) |
- |
0 |
|
- |
Annex A(Season cracking/corrosion test) |
- |
0 |
|
- |
12.4(Thermal tests) |
- |
0 |
|
- |
9.1(Lampholder dimensions) |
- |
0 |
|
- |
11.2(Terminals) |
- |
0 |
|
- |
12.3(Provision for earthing) |
- |
0 |
|
- |
13.1(Construction) |
- |
0 |
|
- |
13.8(Construction) |
- |
0 |
|
- |
14.4(Switched lampholders) |
- |
0 |
|
- |
15.1(Moisture resistance, insulation resistance and electrical strength) |
- |
0 |
|
- |
16.7(Mechanical strength) |
- |
0 |
|
- |
16.8(Mechanical strength) |
- |
0 |
|
- |
21.2(Resistance to excessive residual stresses (season cracking) and to rusting) |
- |
0 |
|
- |
|
19 Mar, 2026 |
- Included.w.e.f.27.01.2025 |
22 |
IS 9815 : Part 1 (1994) |
Servo - Motor operated automatic line voltage correctors: Part 1 correctors for single - Phase applications - Specification (Second Revision) |
Servo - Motor operated automatic line voltage correctors |
95000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 4(Service Conditions) |
- |
0 |
|
- |
Clause 5(Rating) |
- |
0 |
|
- |
Clause 6(Construction) |
- |
0 |
|
- |
Clause 7.1(Insulation) |
- |
7000 |
|
- |
Clause 7.2(Provision for
Earthing) |
- |
7000 |
|
- |
Clause 7.3(Leakage Current Under Normal Operating Conditions) |
- |
7000 |
|
- |
Clause 8.1(Temperature-rise ) |
- |
17000 |
|
- |
Clause 9(Performance Requirement) |
- |
3000 |
|
- |
Clause 10(Marking) |
- |
0 |
|
- |
Clause 11.1(Type Test) |
- |
95000 |
|
- |
Clause 11.2(Acceptance Tests) |
- |
25500 |
|
- |
Clause 11.3(Routine Tests) |
- |
20500 |
|
- |
Clause 11.4(Insulation Resistance
Test) |
- |
7000 |
|
- |
Clause 11.5(High Voltage Test) |
- |
7000 |
|
- |
Clause 11.6(Output Voltage Test) |
- |
3500 |
|
- |
Clause 11.7(No-Load Current Test) |
- |
3500 |
|
- |
Clause 11.8(No-Load Loss Test) |
- |
3500 |
|
- |
Clause 11.9(Load Loss Test
and Efficiency) |
- |
10000 |
|
- |
Clause 11.10(Induced Voltage Test) |
- |
5000 |
|
- |
Clause 11.11(Test for Continuous
Operation) |
- |
15000 |
|
- |
Clause 11.12(Temperature-Rise Test) |
- |
17000 |
|
- |
Clause 11.13(Test for Rate of
Correction) |
- |
3500 |
|
- |
Clause 11.14(Locked Rotor Test
For Servo-Motor) |
- |
9000 |
|
- |
Clause 11.15(Damp Heat Test) |
- |
22000 |
|
- |
Clause 4(Service Conditions) |
- |
0 |
|
- |
Clause 5(Rating) |
- |
0 |
|
- |
Clause 6(Construction) |
- |
0 |
|
- |
Clause 7.1(Insulation) |
- |
0 |
|
- |
Clause 7.2(Provision for
Earthing) |
- |
0 |
|
- |
Clause 7.3(Leakage Current Under Normal Operating Conditions) |
- |
0 |
|
- |
Clause 8.1(Temperature-rise ) |
- |
0 |
|
- |
Clause 9(Performance Requirement) |
- |
0 |
|
- |
Clause 10(Marking) |
- |
0 |
|
- |
Clause 11.1(Type Test) |
- |
0 |
|
- |
Clause 11.2(Acceptance Tests) |
- |
0 |
|
- |
Clause 11.3(Routine Tests) |
- |
0 |
|
- |
Clause 11.4(Insulation Resistance
Test) |
- |
0 |
|
- |
Clause 11.5(High Voltage Test) |
- |
0 |
|
- |
Clause 11.6(Output Voltage Test) |
- |
0 |
|
- |
Clause 11.7(No-Load Current Test) |
- |
0 |
|
- |
Clause 11.8(No-Load Loss Test) |
- |
0 |
|
- |
Clause 11.9(Load Loss Test
and Efficiency) |
- |
0 |
|
- |
Clause 11.10(Induced Voltage Test) |
- |
0 |
|
- |
Clause 11.11(Test for Continuous
Operation) |
- |
0 |
|
- |
Clause 11.12(Temperature-Rise Test) |
- |
0 |
|
- |
Clause 11.13(Test for Rate of
Correction) |
- |
0 |
|
- |
Clause 11.14(Locked Rotor Test
For Servo-Motor) |
- |
0 |
|
- |
Clause 11.15(Damp Heat Test) |
- |
0 |
|
- |
Clause 4(Service Conditions) |
- |
0 |
|
- |
Clause 5(Rating) |
- |
0 |
|
- |
Clause 6(Construction) |
- |
0 |
|
- |
Clause 7.1(Insulation) |
- |
0 |
|
- |
Clause 7.2(Provision for
Earthing) |
- |
0 |
|
- |
Clause 7.3(Leakage Current Under Normal Operating Conditions) |
- |
0 |
|
- |
Clause 8.1(Temperature-rise ) |
- |
0 |
|
- |
Clause 9(Performance Requirement) |
- |
0 |
|
- |
Clause 10(Marking) |
- |
0 |
|
- |
Clause 11.1(Type Test) |
- |
0 |
|
- |
Clause 11.2(Acceptance Tests) |
- |
0 |
|
- |
Clause 11.3(Routine Tests) |
- |
0 |
|
- |
Clause 11.4(Insulation Resistance
Test) |
- |
0 |
|
- |
Clause 11.5(High Voltage Test) |
- |
0 |
|
- |
Clause 11.6(Output Voltage Test) |
- |
0 |
|
- |
Clause 11.7(No-Load Current Test) |
- |
0 |
|
- |
Clause 11.8(No-Load Loss Test) |
- |
0 |
|
- |
Clause 11.9(Load Loss Test
and Efficiency) |
- |
0 |
|
- |
Clause 11.10(Induced Voltage Test) |
- |
0 |
|
- |
Clause 11.11(Test for Continuous
Operation) |
- |
0 |
|
- |
Clause 11.12(Temperature-Rise Test) |
- |
0 |
|
- |
Clause 11.13(Test for Rate of
Correction) |
- |
0 |
|
- |
Clause 11.14(Locked Rotor Test
For Servo-Motor) |
- |
0 |
|
- |
Clause 11.15(Damp Heat Test) |
- |
0 |
|
- |
|
19 Mar, 2026 |
- Included .w.e.f.11.02.2025 |
23 |
IS 302 : Part 1 (2024) |
Household and Similar Electrical Appliances â Safety Part 1 General Requirements (Seventh Revision) |
Household and Similar Electrical Appliances |
225000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12(Charging of metal-ion batteries) |
- |
7500 |
|
- |
6(Classification) |
- |
500 |
|
- |
5(General conditions for the tests) |
- |
1000 |
|
- |
19.11.4.7(Harmonics) |
- |
150000 |
|
- |
19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
150000 |
|
- |
19.11.4.5(Immunity to conducted discharges) |
- |
150000 |
|
- |
19.11.4.4(Surge immunity test) |
- |
150000 |
|
- |
19.11.4.3(Fast transient bursts) |
- |
150000 |
|
- |
19.11.4.2(Radiated fields) |
- |
150000 |
|
- |
19.11.4.1(Electrostatic discharges) |
- |
150000 |
|
- |
11.8(Temperature rise) |
- |
4000 |
|
- |
11.7(Duration corresponding) |
- |
4000 |
|
- |
11.6(Combined appliances) |
- |
4000 |
|
- |
11.5(Motor-operated appliances) |
- |
4000 |
|
- |
11.4(Heating appliances) |
- |
4000 |
|
- |
8.1.5(Live parts of built-in appliances) |
- |
2500 |
|
- |
18(Endurance) |
- |
0 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
2500 |
|
- |
16(Leakage current and electric strength) |
- |
2000 |
|
- |
4(General requirement) |
- |
500 |
|
- |
32(Radiation Toxicity and Similar Hazards) |
- |
2000 |
|
- |
31(Resistance to Rusting) |
- |
2500 |
|
- |
30.2(Needle Flame Test) |
- |
4500 |
|
- |
30.2(Glow Wire Test) |
- |
4500 |
|
- |
30.1(Ball pressure test) |
- |
4500 |
|
- |
29(clearance, creepage distances and solid insulation) |
- |
2500 |
|
- |
28(Screw test and connections) |
- |
2000 |
|
- |
27(Provision for earthing) |
- |
2000 |
|
- |
26(Terminals for external conductors) |
- |
2500 |
|
- |
25(Supply connection and external flexible cords) |
- |
3500 |
|
- |
23(Internal wiring) |
- |
3000 |
|
- |
22(Construction) |
- |
10000 |
|
- |
21(Mechanical Strength) |
- |
3000 |
|
- |
20(Stability and mechanical hazards) |
- |
3000 |
|
- |
19(Abnormal Operation) |
- |
150000 |
|
- |
18(Endurance) |
- |
0 |
|
- |
17(Over Load Protection of Transformers and associated circuits) |
- |
2500 |
|
- |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
2000 |
|
- |
16.2(Leakage Current (after Clause 15)) |
- |
2000 |
|
- |
16.1(General) |
- |
2000 |
|
- |
16.0(General) |
- |
2000 |
|
- |
15.3(Humidity Test) |
- |
6000 |
|
- |
15.2(Spillage Test) |
- |
6000 |
|
- |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
6000 |
|
- |
15.0(Moisture resistance) |
- |
6000 |
|
- |
14(Transient Over Voltages) |
- |
2000 |
|
- |
13.3(Electric Strength at operating temperature) |
- |
2000 |
|
- |
13.2(Leakage current at operating temperature) |
- |
2000 |
|
- |
13(Leakage current and electric strength at operating temperature) |
- |
2000 |
|
- |
11.3(Heating) |
- |
4000 |
|
- |
11.2(General) |
- |
4000 |
|
- |
11.1(General) |
- |
4000 |
|
- |
10.2(Current input) |
- |
3000 |
|
- |
10.1(Power input) |
- |
3000 |
|
- |
9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
8.1.4(Protection against live parts against protective impedance) |
- |
2500 |
|
- |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
2500 |
|
- |
8.1.2(Protection against live parts in openings) |
- |
2500 |
|
- |
8.1.1(Protection against live parts in all positions) |
- |
2500 |
|
- |
7(Marking and instructions) |
- |
1000 |
|
- |
A.2(Earth continuity test) |
- |
2000 |
|
- |
Annex C(Ageing test on motors) |
- |
22500 |
|
- |
Annex D(Thermal motor protectors) |
- |
1500 |
|
- |
15.2(Moisture resistance) |
- |
6000 |
|
- |
19.17(Abnormal operation) |
- |
150000 |
|
- |
20.1(Stability and mechanical hazards) |
- |
3000 |
|
- |
21.2(Mechanical strength) |
- |
3000 |
|
- |
21.3(Mechanical strength) |
- |
3000 |
|
- |
22.5(Construction) |
- |
10000 |
|
- |
22.6(Construction) |
- |
10000 |
|
- |
22.11(Construction) |
- |
10000 |
|
- |
22.16(Construction) |
- |
10000 |
|
- |
23.3(Internal wiring) |
- |
3000 |
|
- |
25(Supply connection and external flexible cords) |
- |
3500 |
|
- |
25.7(Supply connection and external flexible cords) |
- |
3500 |
|
- |
25.14(Supply connection and external flexible cords) |
- |
3500 |
|
- |
25.15(Supply connection and external flexible cords) |
- |
3500 |
|
- |
26.5(Terminals for external conductors) |
- |
2500 |
|
- |
27.5(Provision for earthing) |
- |
2000 |
|
- |
28.1(Screws and connections) |
- |
2000 |
|
- |
B.22.1(Construction) |
- |
10000 |
|
- |
B.22.3(Construction) |
- |
10000 |
|
- |
B.22.4(Construction) |
- |
10000 |
|
- |
B.22.5(Construction) |
- |
10000 |
|
- |
|
19 Mar, 2026 |
- Included w.e.f.30.06.2025
exclusion
Cl 24 (Components)
Cl 22.32 (Construction)
Cl 22.42 (Construction) |
24 |
IS/IEC 60947 : Part 5 : Sec 1 (2016) |
Low-Voltage Switchgear And Control Gear : Part 5-1 Control Circuit Devices And Switching Elements Electromechanical Control Circuit Devices |
Control Circuit Devices And Switching Elements Electromechanical Control Circuit Devices |
850000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.3.2.4(Electrostatic discharges) |
- |
75000 |
|
- |
7.3.2.5(Radiated radio-frequency electromagnetic fields) |
- |
100000 |
|
- |
7.3.2.6(Electrical fast transients/bursts) |
- |
75000 |
|
- |
7.3.2.7(Surges) |
- |
75000 |
|
- |
7.3.2.8(Conducted disturbances induced by radio-frequency fields) |
- |
150000 |
|
- |
7.3.2.9(Power-frequency magnetic fields) |
- |
75000 |
|
- |
7.3.2.10(Voltage dips and interruptions) |
- |
75000 |
|
- |
7.3.2.11(Harmonics in the supply) |
- |
75000 |
|
- |
7.3.3(Emission) |
- |
300000 |
|
- |
|
19 Mar, 2026 |
- Included w.e.f.30.06.2025
Only for EMI/EMC Testing. |
25 |
IS/IEC 60947 : Part 4 : Sec 1 (2018) |
Low-Voltage switchgear and controlgear : Part 4-1 Contactors and motor starters electromechanical contactors and motor-Starters |
Contactors and motor starters electromechanical contactors and motor-Starters |
850000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.3(Electromagnetic compatibility (EMC)) |
- |
850000 |
|
- |
8.3.2(Immunity) |
- |
550000 |
|
- |
8.3.3(Emission) |
- |
300000 |
|
- |
9.4.2(Immunity) |
- |
550000 |
|
- |
9.4.2.2(Electrostatic discharge) |
- |
75000 |
|
- |
9.4.2.3(Radiated radio-frequency electromagnetic field) |
- |
100000 |
|
- |
9.4.2.4(Conducted disturbances induced by radio-frequency fields) |
- |
150000 |
|
- |
9.4.2.5(Electrical fast transient/bursts) |
- |
75000 |
|
- |
9.4.2.6(Surges) |
- |
75000 |
|
- |
9.4.2.7(Power frequency magnetic field) |
- |
75000 |
|
- |
9.4.2.8(Voltage dips and short-time interruptions) |
- |
75000 |
|
- |
9.4.2.9(Harmonics in the supply) |
- |
75000 |
|
- |
9.4.3(Emission) |
- |
300000 |
|
- |
|
19 Mar, 2026 |
- Included .w.e.f.30.06.2025
Only for EMI/EMC testing. |
26 |
IS/IEC 60947 : PART 3 (2020) |
Low-Voltage Switchgear and Controlgear: Part 3 Switches Disconnectors Switch-Disconnectors and Fuse-Combination Units |
Switches Disconnectors Switch-Disconnectors And Fuse-Combination Units |
850000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9.4.2(Immunity) |
- |
550000 |
|
- |
9.4.3(Emission) |
- |
300000 |
|
- |
|
19 Mar, 2026 |
- Included w.e.f.30.06.2025
Only For EMI/EMC Testing |
27 |
IS/IEC 60947 : Part 2 (2016) |
Low - Voltage switchgear and controlgear: Part 2 circuit - Breakers (First Revision) |
125 |
850000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.3 Annexure J Table J.1(Electrostatic discharges) |
- |
75000 |
|
- |
7.3 Annexure J Table J.1("Radiated radio-frequency electromagnetic fields") |
- |
100000 |
|
- |
7.3 Annexure J Table J.1("Electrical fast transients/bursts") |
- |
75000 |
|
- |
7.3 Annexure J Table J.1("Radiated radio-frequency electromagnetic fields") |
- |
0 |
|
- |
7.3 Annexure J Table J.1(Surges) |
- |
75000 |
|
- |
7.3 Annexure J Table J.1("Conducted disturbances induced by radio frequency fields") |
- |
150000 |
|
- |
7.3 Annexure J Table J.1("Voltage dips and interruptions") |
- |
75000 |
|
- |
7.3 Annexure J Table J.3("Conducted RF disturbances 150 kHz to 30 MHz") |
- |
150000 |
|
- |
7.3 Annexure J Table J.3("Radiated RF disturbances 30 MHz to 1 000 MHz") |
- |
150000 |
|
- |
|
19 Mar, 2026 |
- Included w.e.f.30.06.2025
Only For EMI/EMC Testing. |
28 |
IS 13730 : Part 0 : Sec 1 (2018) |
Specifications for particular types of winding wires: Part 0 general requirements: Sec 1 enamelled round copper wire (Second Revision) |
Enamelled Round Copper Wire |
195000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Dimensions) |
- |
2500 |
|
- |
4.1(Conductor diameter) |
- |
2500 |
|
- |
4.2(Out of roundness of conductor) |
- |
2500 |
|
- |
4.3(Minimum increase in diameter due to
the insulation and the bonding layer) |
- |
2500 |
|
- |
4.4(Maximum overall diameter) |
- |
2500 |
|
- |
5(Electrical resistance) |
- |
5000 |
|
- |
6(Elongation) |
- |
5000 |
|
- |
7(Springiness) |
- |
5000 |
|
- |
8.1(Mandrel winding test) |
- |
5000 |
|
- |
8.2(Stretching test) |
- |
5000 |
|
- |
8.3(Jerk test) |
- |
5000 |
|
- |
8.4(Peel test) |
- |
5000 |
|
- |
9(Heat shock) |
- |
10000 |
|
- |
10(Cut-through) |
- |
7500 |
|
- |
11(Resistance to abrasion) |
- |
7500 |
|
- |
12(Resistance to solvents) |
- |
7500 |
|
- |
13(Breakdown voltage) |
- |
9500 |
|
- |
13.1(General) |
- |
0 |
|
- |
13.2(Nominal conductor diameters
up to and including 0,100 mm) |
- |
2500 |
|
- |
13.3(Nominal conductor diameters over
0,100 mm up to and including 2,500 mm) |
- |
2500 |
|
- |
13.4(Nominal conductor diameters over 2,500 mm) |
- |
2500 |
|
- |
14(Continuity of insulation) |
- |
7500 |
|
- |
15(Temperature index) |
- |
100000 |
|
- |
16(Resistance to refrigerants) |
- |
2500 |
|
- |
17(Solderability) |
- |
2500 |
|
- |
18(Heat or solvent bonding) |
- |
2500 |
|
- |
19(Dielectric dissipation factor) |
- |
2500 |
|
- |
20(Resistance to transformer oil) |
- |
2500 |
|
- |
21(Loss of mass) |
- |
2500 |
|
- |
23(Pin hole test) |
- |
7500 |
|
- |
30(Packaging) |
- |
500 |
|
- |
4(Dimensions) |
- |
0 |
|
- |
4.1(Conductor diameter) |
- |
0 |
|
- |
4.2(Out of roundness of conductor) |
- |
0 |
|
- |
4.3(Minimum increase in diameter due to
the insulation and the bonding layer) |
- |
0 |
|
- |
4.4(Maximum overall diameter) |
- |
0 |
|
- |
5(Electrical resistance) |
- |
0 |
|
- |
6(Elongation) |
- |
0 |
|
- |
7(Springiness) |
- |
0 |
|
- |
8.1(Mandrel winding test) |
- |
0 |
|
- |
8.2(Stretching test) |
- |
0 |
|
- |
8.3(Jerk test) |
- |
0 |
|
- |
8.4(Peel test) |
- |
0 |
|
- |
9(Heat shock) |
- |
0 |
|
- |
10(Cut-through) |
- |
0 |
|
- |
11(Resistance to abrasion) |
- |
0 |
|
- |
12(Resistance to solvents) |
- |
0 |
|
- |
13(Breakdown voltage) |
- |
0 |
|
- |
13.1(General) |
- |
0 |
|
- |
13.2(Nominal conductor diameters
up to and including 0,100 mm) |
- |
0 |
|
- |
13.3(Nominal conductor diameters over
0,100 mm up to and including 2,500 mm) |
- |
0 |
|
- |
13.4(Nominal conductor diameters over 2,500 mm) |
- |
0 |
|
- |
14(Continuity of insulation) |
- |
0 |
|
- |
15(Temperature index) |
- |
0 |
|
- |
16(Resistance to refrigerants) |
- |
0 |
|
- |
17(Solderability) |
- |
0 |
|
- |
18(Heat or solvent bonding) |
- |
0 |
|
- |
19(Dielectric dissipation factor) |
- |
0 |
|
- |
20(Resistance to transformer oil) |
- |
0 |
|
- |
21(Loss of mass) |
- |
0 |
|
- |
23(Pin hole test) |
- |
0 |
|
- |
30(Packaging) |
- |
0 |
|
- |
|
19 Mar, 2026 |
- Included w.e.f 15.01.2025 |
29 |
IS 15884 (2024) |
ALTERNATING CURRENT DIRECT CONNECTED STATIC PREPAYMENT METERS FOR ACTIVE ENERGY CLASS 1 AND 2 SPECIFICATION |
Alternating Current Direct Connected Static Prepayment Meters for Active Energy of Class 1 and 2 |
253500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(GENERAL REQUIREMENTS) |
- |
0 |
|
- |
5.2.1(Spring Hammer Test) |
- |
5833 |
|
- |
5.2.2(Shock Test) |
- |
5833 |
|
- |
5.2.3(Vibration Test) |
- |
5833 |
|
- |
5.2.4(Test of Resistance to Heat and Fire) |
- |
5000 |
|
- |
5.2.5(Tests of Protection against Penetration of Dust and Water) |
- |
7500 |
|
- |
5.3.1(Dry Heat Test) |
- |
7500 |
|
- |
5.3.2(Cold Test) |
- |
7500 |
|
- |
5.3.3(Damp Heat Cyclic Test) |
- |
7500 |
|
- |
5.4.1(Test of Power Consumption) |
- |
10000 |
|
- |
5.4.2(Test of influence of voltage dips and interruptions) |
- |
10000 |
|
- |
5.4.3(Test of Influence of Short-Time Overcurrent) |
- |
12500 |
|
- |
5.4.4(Test of Influence of Self-Heating) |
- |
12500 |
|
- |
5.4.5(Test of Influence of Heating) |
- |
10000 |
|
- |
5.4.6.2(Impulse voltage test) |
- |
5833 |
|
- |
5.4.6.3(a.c. voltage test) |
- |
5833 |
|
- |
5.4.6.4(Insulation resistance test) |
- |
5833 |
|
- |
5.5.2(Test of Immunity to Electrostatic Discharges) |
- |
50000 |
|
- |
5.5.3(Test of Immunity to Electromagnetic HF Fields) |
- |
50000 |
|
- |
5.5.4(Fast Transient Burst Test) |
- |
50000 |
|
- |
5.5.5(Radio Interference Measurement) |
- |
50000 |
|
- |
5.5.6(Surge Immunity Test) |
- |
50000 |
|
- |
5.6.2(Test of Influence Quantities) |
- |
2500 |
|
- |
5.6.3(Test of No-Load Condition) |
- |
2500 |
|
- |
5.6.4(Test of Starting Condition) |
- |
2500 |
|
- |
5.6.5(Test of Meter Constant) |
- |
2500 |
|
- |
5.6.6(Interpretation of Test Results) |
- |
2500 |
|
- |
5.7(Test of the Load Switch operation for payment function) |
- |
5000 |
|
- |
5.8(Test of Charging Functions) |
- |
7500 |
|
- |
5.9(Interruption and Restoration of the Load for Emergency Credit Facility (if applicable)) |
- |
7500 |
|
- |
5.10(Tests of the Load Switch operation at Different Voltages and Temperature) |
- |
15000 |
|
- |
6(FUNCTIONAL REQUIREMENTS) |
- |
10000 |
|
- |
|
19 Mar, 2026 |
- Included w.e.f 02.01.2025 |
30 |
IS 14900 (2018) |
Transparent float glass - Specification (First Revision) |
Transparent Float Glass |
575000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 4.1(A glass shall be deemed to be manufactured using float glass technology if the tin side of the glass can be identified by the UV light test as prescribed in Annex A.) |
- |
3200 |
|
- |
Cl.4.2 ( Annexure B Table 1)(The minimum value for visual light transmission for a flat, transparent clear float glass, when measured as per Annex B, shall be as prescribed in Table 1) |
- |
1900 |
|
- |
Cl.4.3.1 (Table 2)(Float glass thickness shall be measured with micrometer or calipers, which is graduated to 0.01 mm or with a measuring instrument having an equivalent accuracy. The tolerances on thickness shall be as specified in Table 2.) |
- |
2100 |
|
- |
Cl.4.3.2.1(the finished pane shall not be larger than a prescribed rectangle of dimensions (W + v, L + v), or smaller than a prescribed rectangle of dimensions (W – v, L – v), where v is the maximum tolerance on nominal dimensions. The corresponding sides of the prescribed rectangles shall be parallel to each other and these rectangles shall have a common centre (see Fig.1).) |
- |
2000 |
|
- |
Cl.4.3.2.2(The length and width of the glass on cut sizes shall be measured with a steel scale (tape) which is graduated to 1 mm. The measurement shall be made on adjacent two sides. The tolerances on nominal dimensions length L, and width W, shall be ± 5mm.) |
- |
2000 |
|
- |
Cl.4.3.3(The tolerances on diagonals shall be as specified in Table 3.) |
- |
2000 |
|
- |
Cl.4.4 (Annex C Table 8)(The glass shall be viewed under the conditions of observation as described in Annex C, and the angle at which there is no optical distortion shall be noted. This angle shall not be less than the appropriate critical viewing angle (see Table 8).) |
- |
2000 |
|
- |
Cl.4.5.1(see Table 4(Spot faults are categorized based on their size (see Table 4). Determination of spot faults shall be done in accordance with Annex D. The maximum permissible number of the different categories of spot faults shall be as per Tables 5 and 6.) |
- |
3000 |
|
- |
Cl.4.5.2(Annexure E)(There shall be no reams, strings and lines distinguished visually when tested in accordance with Annex E.) |
- |
3500 |
|
- |
Cl.4.5.3(Annexure E)(There shall not be any linear/extended faults when tested in accordance with Annex E.) |
- |
0 |
|
- |
Cl.4.6(Fig.2)(Defects in shape such as chipping of cut side, shelling, protrusion, slicing off, corners on/off, etc as shown in Fig. 2 shall be such that the deviation from the cutting line when viewing perpendicularly to the surface of plate glass is not more than the nominal value of thickness of glass or 10 mm, whichever is smaller.) |
- |
2800 |
|
- |
Cl.4.7 (Annexure F)(Material may be tested for bloom freedom as per Annex F whenever required by the purchaser.) |
- |
550000 |
|
- |
4.3.1(Thickness) |
- |
2100 |
|
- |
4.3.1(Thickness test) |
- |
2100 |
|
- |
4.3.1(Thickness test) |
- |
2100 |
|
- |
Cl 4.1(A glass shall be deemed to be manufactured using float glass technology if the tin side of the glass can be identified by the UV light test as prescribed in Annex A.) |
- |
0 |
|
- |
Cl.4.2 ( Annexure B Table 1)(The minimum value for visual light transmission for a flat, transparent clear float glass, when measured as per Annex B, shall be as prescribed in Table 1) |
- |
0 |
|
- |
Cl.4.3.1 (Table 2)(Float glass thickness shall be measured with micrometer or calipers, which is graduated to 0.01 mm or with a measuring instrument having an equivalent accuracy. The tolerances on thickness shall be as specified in Table 2.) |
- |
0 |
|
- |
Cl.4.3.2.1(the finished pane shall not be larger than a prescribed rectangle of dimensions (W + v, L + v), or smaller than a prescribed rectangle of dimensions (W – v, L – v), where v is the maximum tolerance on nominal dimensions. The corresponding sides of the prescribed rectangles shall be parallel to each other and these rectangles shall have a common centre (see Fig.1).) |
- |
0 |
|
- |
Cl.4.3.2.2(The length and width of the glass on cut sizes shall be measured with a steel scale (tape) which is graduated to 1 mm. The measurement shall be made on adjacent two sides. The tolerances on nominal dimensions length L, and width W, shall be ± 5mm.) |
- |
0 |
|
- |
Cl.4.3.3(The tolerances on diagonals shall be as specified in Table 3.) |
- |
0 |
|
- |
Cl.4.4 (Annex C Table 8)(The glass shall be viewed under the conditions of observation as described in Annex C, and the angle at which there is no optical distortion shall be noted. This angle shall not be less than the appropriate critical viewing angle (see Table 8).) |
- |
0 |
|
- |
Cl.4.5.1(see Table 4(Spot faults are categorized based on their size (see Table 4). Determination of spot faults shall be done in accordance with Annex D. The maximum permissible number of the different categories of spot faults shall be as per Tables 5 and 6.) |
- |
0 |
|
- |
Cl.4.5.2(Annexure E)(There shall be no reams, strings and lines distinguished visually when tested in accordance with Annex E.) |
- |
0 |
|
- |
Cl.4.5.3(Annexure E)(There shall not be any linear/extended faults when tested in accordance with Annex E.) |
- |
0 |
|
- |
Cl.4.6(Fig.2)(Defects in shape such as chipping of cut side, shelling, protrusion, slicing off, corners on/off, etc as shown in Fig. 2 shall be such that the deviation from the cutting line when viewing perpendicularly to the surface of plate glass is not more than the nominal value of thickness of glass or 10 mm, whichever is smaller.) |
- |
0 |
|
- |
Cl.4.7 (Annexure F)(Material may be tested for bloom freedom as per Annex F whenever required by the purchaser.) |
- |
0 |
|
- |
4.3.1(Thickness) |
- |
0 |
|
- |
4.3.1(Thickness test) |
- |
0 |
|
- |
4.3.1(Thickness test) |
- |
0 |
|
- |
|
19 Mar, 2026 |
- Included w.e.f 17.03.2025 |