451 |
IS 9103 (1999) |
Specification for Concrete Admixtures - |
- |
-
|
4134/ View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 9, Table- 2 (Dry material content ) |
- |
|
|
|
Clause 9, Table- 2 (Ash content) |
- |
|
|
|
Clause 9, Table- 2 (Relative density) |
- |
|
|
|
Clause 9, Table- 2 (Chloride ion content) |
- |
|
|
|
Clause 9, Table- 2 ( pH) |
- |
|
|
|
|
Complete
|
|
- |
- complete for chemical.; |
452 |
IS 2641 (1989) |
Electric welding accessories - Specification (First Revision) |
- |
-
|
- View breakup
Rs.3000/- for complete testing of product of electrode holders, Rs.1500/- for complete testing of product of return current clamps
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1 (Rated Current, IS 2641) |
- |
|
|
|
5.2.1 (Design and Construction, IS 2641) |
- |
|
|
|
5.2.2.1 (General requirements, IS 2641) |
- |
|
|
|
5.2.2.2 (General requirements, IS 2641) |
- |
|
|
|
5.2.2.3 (General requirements, IS 2641) |
- |
|
|
|
5.2.2.4 (General requirements, IS 2641) |
- |
|
|
|
5.2.2.5 (General requirements, IS 2641) |
- |
|
|
|
5.2.2.6 (General requirements, IS 2641) |
- |
|
|
|
5.2.2.7 (General requirements, IS 2641) |
- |
|
|
|
5.2.2.8 (General requirements, IS 2641) |
- |
|
|
|
5.2.2.9 (General requirements, IS 2641) |
- |
|
|
|
5.2.2.10 (General requirements, IS 2641) |
- |
|
|
|
5.2.2.11 (General requirements, IS 2641) |
- |
|
|
|
5.2.2.12 (General requirements, IS 2641) |
- |
|
|
|
5.2.2.13 (General requirements, IS 2641) |
- |
|
|
|
5.3.3 (Temperature Rise Test, IS 2641) |
- |
|
|
|
5.3.4 (Insulation resistance test, IS 2641) |
- |
|
|
|
5.3.5 (High Voltage Test, IS 2641) |
- |
|
|
|
5.3.6.1 (Test for Impact Strength-Impact test by vertical fall, IS 2641) |
- |
|
|
|
5.3.6.2 (Test for Impact Strength-Lateral impact strength, IS 2641) |
- |
|
|
|
5.3.7 (Test for Flammability and Resistance to Heat, IS 2641) |
- |
|
|
|
5.4 (Marking, IS 2641) |
- |
|
|
|
5.4 (Marking, IS 2641) |
- |
|
|
|
5.4 (Marking, IS 2641) |
- |
|
|
|
|
Complete
|
|
- |
- EXCLUDING Rs.3000/- for complete testing of product of electrode holders, Rs.1500/- for complete testing of product of return current clamps; |
453 |
IS 11552 (2020) |
Liquid Nitrogen Vessels of Capacity up to 75 Litres — Specification ( Second Revision ) |
- |
-
|
- View breakup
Rs. 3600/- + testing charges as per referred ISS (excluding leak tightness test, evaporation loss, performance test, vibration test and accessories).
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.2 (Construction) |
- |
|
|
|
5.1 (Water Capacity) |
- |
|
|
|
7 (Painting) |
- |
|
|
|
5.1 (Water Capacity) |
- |
|
|
|
|
Partial
|
|
- |
- - |
454 |
IS 2556 : Part 7 (1995) |
Vitreous sanitary appliances (Vitreous China) - specification: Part 7 specific requirements of accessories for sanitary appliances |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (DIMENSIONS-STOP END CHANNEL WITH OUTLET-Type A
) |
- |
|
|
|
4 (DIMENSIONS-PLAIN CHENNEL-Type B
) |
- |
|
|
|
4 (DIMENSIONS-PLAIN CHENNEL-Type A
) |
- |
|
|
|
4 (DIMENSIONS-PLAIN CHANNEL WITH SOCKET-Type B
) |
- |
|
|
|
4 (DIMENSIONS-PLAIN CHANNEL WITH SOCKET-Type A
) |
- |
|
|
|
4 (DIMENSIONS-PLAIN CHANNEL WITH SOCKET-Type B
) |
- |
|
|
|
4 (DIMENSIONS-FOOT REST
) |
- |
|
|
|
4 (DIMENSIONS-Traps for Long Pattern and Orilsa Pattern Pans
) |
- |
|
|
|
4 (DIMENSIONS-- Ovality permissible within the variation allowed for the dimensioN
) |
- |
|
|
|
4 (DIMENSIONS-- FLOOR TRAP) |
- |
|
|
|
4 (DIMENSIONS-TYPICAL ILLUSTRATION OF VITRIOUS SHOWER ROSH) |
- |
|
|
|
5 (CONSTRUCTION) |
- |
|
|
|
6 (FINISH) |
- |
|
|
|
7.1 (Performance Test) |
- |
|
|
|
7.2 (FLUSHING TESTS-Toilet Paper Test-IS 2556(P-3)) |
- |
|
|
|
|
Partial
|
|
- |
- - |
455 |
IS 12406 (2003) |
Medium density fibre boards for general purpose - Specification (First Revision) |
- |
-
|
- View breakup
Rs. 30007/- excluding Steady state formaldehyde emission value and linear expansion for length and width.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 4 ( Types) |
- |
|
|
|
Cl 7 (Finish) |
- |
|
|
|
Cl 8 (Dimensions & Tolerances) |
- |
|
|
|
Cl 11.4 (Test For Density) |
- |
|
|
|
Cl 11.6 (Test For water Absorption) |
- |
|
|
|
Cl 11.7.1 (Due To General Absorption) |
- |
|
|
|
Cl 11.7.2 (Due To Surfacel Absorption) |
- |
|
|
|
Cl 11.8 (Tesr For Modulus Of Elasticity & Mudulus Of Rupture) |
- |
|
|
|
Cl 11.9 (Test For Internal Bond) |
- |
|
|
|
Cl 11.10 (Test For Screw Withdrawal Strength) |
- |
|
|
|
|
Partial
|
|
- |
- IS Superseded by newer version; |
456 |
IS 369 (2019) |
Household electric direct - Acting room heaters - Performance requirements (Fourth Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6 of IS 302-2-30:2007 (Classification) |
- |
|
|
|
Cl.6 of IS 302-2-30:2007 (Classification) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.8 of IS 302-2-30:2007 &IS:302-1:2008 (Protection Against Access to Live Parts) |
- |
|
|
|
Cl.10 of IS 302-2-30:2007 &IS:302-1:2008 (Power Input and Current) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.13 of IS 302-2-30:2007 &IS:302-1:2008 (Leakage Current & Electric Strength at operating temp) |
- |
|
|
|
Cl.13 of IS 302-2-30:2007 &IS:302-1:2008 (Leakage Current & Electric Strength at operating temp) |
- |
|
|
|
Cl.15 of IS 302-2-30:2007 &IS:302-1:2008 (Moisture Resistance) |
- |
|
|
|
Cl.15 of IS 302-2-30:2007 &IS:302-1:2008 (Moisture Resistance) |
- |
|
|
|
Cl.16 of IS 302-2-30:2007 &IS:302-1:2008 (Leakage Current & Electric Strength ) |
- |
|
|
|
Cl.16 of IS 302-2-30:2007 &IS:302-1:2008 (Leakage Current & Electric Strength ) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.20 of IS 302-2-30:2007 &IS:302-1:2008 (Stability & Mechanical Hazards) |
- |
|
|
|
Cl.21 of IS 302-2-30:2007 &IS:302-1:2008 (Mechanical Strength) |
- |
|
|
|
Cl.21 of IS 302-2-30:2007 &IS:302-1:2008 (Mechanical Strength) |
- |
|
|
|
Cl.21 of IS 302-2-30:2007 &IS:302-1:2008 (Mechanical Strength) |
- |
|
|
|
Cl.21 of IS 302-2-30:2007 &IS:302-1:2008 (Mechanical Strength) |
- |
|
|
|
Cl.21 of IS 302-2-30:2007 &IS:302-1:2008 (Mechanical Strength) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.25 of IS 302-2-30:2007 &IS:302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25 of IS 302-2-30:2007 &IS:302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25 of IS 302-2-30:2007 &IS:302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25 of IS 302-2-30:2007 &IS:302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25 of IS 302-2-30:2007 &IS:302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25 of IS 302-2-30:2007 &IS:302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25 of IS 302-2-30:2007 &IS:302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25 of IS 302-2-30:2007 &IS:302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25 of IS 302-2-30:2007 &IS:302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25 of IS 302-2-30:2007 &IS:302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25 of IS 302-2-30:2007 &IS:302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25 of IS 302-2-30:2007 &IS:302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.26 of IS 302-2-30:2007 &IS:302-1:2008 (Terminal for External Conductors) |
- |
|
|
|
Cl.27 of IS 302-2-30:2007 &IS:302-1:2008 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 302-2-30:2007 &IS:302-1:2008 (Provision for Earthing) |
- |
|
|
|
Cl.28 of IS 302-2-30:2007 &IS:302-1:2008 (Screws and Connections) |
- |
|
|
|
Cl.29 of IS 302-2-30:2007 &IS:302-1:2008 (Clearances, Creepage Distances and Solid Insulation.) |
- |
|
|
|
Cl.29 of IS 302-2-30:2007 &IS:302-1:2008 (Clearances, Creepage Distances and Solid Insulation.) |
- |
|
|
|
Cl.30 of IS 302-2-30:2007 &IS:302-1:2008 (Resistance to Heat and Fire.) |
- |
|
|
|
Cl.30 of IS 302-2-30:2007 &IS:302-1:2008 (Resistance to Heat and Fire.) |
- |
|
|
|
Cl.31 of IS 302-2-30:2007 &IS:302-1:2008 (Resistance to Rusting) |
- |
|
|
|
Cl.7 of IS 369:2019 (Dimensions) |
- |
|
|
|
Cl.7 of IS 369:2019 (Dimensions) |
- |
|
|
|
Cl.7 of IS 369:2019 (Dimensions) |
- |
|
|
|
Cl.9 of IS 369:2019 (Temperature rises of surfaces surrounding the heater) |
- |
|
|
|
Cl.9 of IS 369:2019 (Temperature rises of surfaces surrounding the heater) |
- |
|
|
|
Cl.9 of IS 369:2019 (Temperature rises of surfaces surrounding the heater) |
- |
|
|
|
Cl.9 of IS 369:2019 (Temperature rises of surfaces surrounding the heater) |
- |
|
|
|
Cl.9 of IS 369:2019 (Temperature rises of surfaces surrounding the heater) |
- |
|
|
|
Cl.10 of IS 369:2019 (Warming-up time of the heater) |
- |
|
|
|
Cl.14 of IS 369:2019 (Inrush current) |
- |
|
|
|
|
Partial
|
|
- |
- - |
457 |
IS 8462 (1977) |
Specification for sterilizer, portable, vertical, pressure type |
- |
-
|
For sterilizers with painted steel stand Rs.9580/-. For View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7 (Heating Elements for Electrically Operated Sterilizer) |
- |
|
|
|
|
Complete
|
|
- |
- - |
458 |
IS 5022 (1989) |
Sterilizer, instruments, table model (Third Revision) |
- |
-
|
- View breakup
Rs. 1350/- + charges as per respective ISS (excluding thermostat and kerosene operation)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.2.1 (Electric Operation (IS 5022)) |
- |
|
|
|
8.2.1 (Electric Operation (IS 5022)) |
- |
|
|
|
8.2.1 (Electric Operation (IS 5022)) |
- |
|
|
|
8.2.2 (Electric Operation (IS 5022)) |
- |
|
|
|
8.2.3 (Heating Element (IS 4159)) |
- |
|
|
|
8.2.4 (Thermostat (IS 5022)) |
- |
|
|
|
4.1 (Design) |
- |
|
|
|
5.1, Table 1 (Length (IS 5022)) |
- |
|
|
|
5.1, Table 1 (Width (IS 5022)) |
- |
|
|
|
5.1, Table 1 (Working Depth (IS 5022)) |
- |
|
|
|
5.2 (Thickness of Body (IS 5022)) |
- |
|
|
|
5.2 ( Thickness of Lid (IS 5022)) |
- |
|
|
|
5.2 ( Thickness of Tray (IS 5022)) |
- |
|
|
|
5.2 ( Dia of Handle (IS 5022)) |
- |
|
|
|
5.2 (Thickness of Handle link - connecting the handle liver (IS 5022)) |
- |
|
|
|
5.2 (Thickness of Handle link - connecting the handle lid (IS 5022)) |
- |
|
|
|
6.1 (Construction (IS 5022)) |
- |
|
|
|
Clause - 3.1 (CARBON) |
- |
|
|
|
Clause - 3.1 (SULPHUR) |
- |
|
|
|
Clause - 3.1 (PHOSPHURS) |
- |
|
|
|
Clause - 3.1 (MANGANESE) |
- |
|
|
|
Clause - 3.1 (NITROGEN) |
- |
|
|
|
Clause - 3.1 (SILICON) |
- |
|
|
|
Clause - 3.1 (CHROMIUM) |
- |
|
|
|
Clause - 3.1 (NICKEL) |
- |
|
|
|
|
Partial
|
|
- |
- - |
459 |
IS 2556 : Part 15 (2004) |
Vitreous sanitary appliances (Vitreous China) - Specification: Part 15 specific requirements of universal water closets |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3 (General requirements-Application of Glazing-IS 2556 (Part 1)) |
- |
|
|
|
3 (General requirements-Application of Glazing-IS 2556 (Part 1)) |
- |
|
|
|
3 (General requirements-Application of Glazing-IS 2556 (Part 1)) |
- |
|
|
|
3 (General requirements-Permissible blemishes or defects (WC apns, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-General-Wavy finiah-IS 2556 (Part 1)) |
- |
|
|
|
3 (General requirements-Permissible blemishes or defects (WC apns, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-General-Warpage -IS 2556 (Part 1)) |
- |
|
|
|
3 (General requirements-Permissible blemishes or defects (WC apns, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-General-Discoloration-IS 2556 (Part 1)) |
- |
|
|
|
3 (General requirements-Permissible blemishes or defects (WC apns, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-·Flushing surface and horizontal face of WC pans,iDI lurfaco and horizontal tace of rima of we pans, Squatting pans bidets and urinals-Spots. blisters and pinholes-IS 2556 (Part 1)) |
- |
|
|
|
3 (General requirements-Permissible blemishes or defects (WC apns, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-Flushing surface and horizontal face of WC pans,iDI lurfaco and horizontal tace of rima of we pans, Squatting pans bidets and urinals-Bubbles and specks-IS 2556 (Part 1)) |
- |
|
|
|
3 (General requirements-Permissible blemishes or defects (WC apns, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-Visible surfaces other than above-Polishing Marks-IS 2556 (Part 1)) |
- |
|
|
|
3 (General requirements-Permissible blemishes or defects (WC apns, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-Visible surfaces other than above-Spots, blisters and
pinholes -IS 2556 (Part 1)) |
- |
|
|
|
3 (General requirements-Permissible blemishes or defects (WC apns, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-Visible surfaces other than above-Bubbles and specks -IS 2556 (Part 1)) |
- |
|
|
|
3 (General requirements-Permissible blemishes or defects (WC apns, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-Visible surfaces other than above-Polishing mark -IS 2556 (Part 1)) |
- |
|
|
|
3 (General requirements-Permissible blemishes or defects (Wash Basins, Laboratory sinks and drinking fountains)-General-Wavy finiah-IS 2556 (Part 1))) |
- |
|
|
|
3 (General requirements-Permissible blemishes or defects (Wash Basins, Laboratory sinks and drinking fountains)-General-Warpages-IS 2556 (Part 1))) |
- |
|
|
|
3 (General requirements-Permissible blemishes or defects (Wash Basins, Laboratory sinks and drinking fountains)-General-Dislocations-IS 2556 (Part 1))) |
- |
|
|
|
3 (General requirements-Permissible blemishes or defects (Wash Basins, Laboratory sinks and drinking fountains)-Service space top of slab inside of bowl, front of fascis-Spots, blisters and pinholes-IS 2556 (Part 1))) |
- |
|
|
|
3 (General requirements-Permissible blemishes or defects (Wash Basins, Laboratory sinks and drinking fountains)-Service space top of slab inside of bowl, front of fascis-Polishing marks-IS 2556 (Part 1))) |
- |
|
|
|
3 (General requirements-Permissible blemishes or defects (Wash Basins, Laboratory sinks and drinking fountains)-Face of intrnal, back and side-Polishing marks-IS 2556 (Part 1))) |
- |
|
|
|
3 (General requirements-Permissible blemishes or defects (Wash Basins, Laboratory sinks and drinking fountains)-Face of intrnal, back and side-Spots, blisters and pinholes-IS 2556 (Part 1))) |
- |
|
|
|
3 (General requirements-Permissible blemishes or defects (Flushing cisterns, Auto cisterns and covers)-Visual surface-wavy finish-IS 2556 (Part 1))) |
- |
|
|
|
3 (General requirements-Thickness
IS 2556 (Part 1)) |
- |
|
|
|
3 (General requirements-PERFORMANCE REQUIllEMENTS-WARPAGE IS 2556 (Part 1)) |
- |
|
|
|
3 (General requirements-PERFORMANCE REQUIllEMENTS-WATER ABSORBTION - Individual IS 2556 (Part 1)) |
- |
|
|
|
4 (SIZES) |
- |
|
|
|
5.1-table 1 (DIMENSIONS AND TOLERANCES-L) |
- |
|
|
|
5.1-table 1 (DIMENSIONS AND TOLERANCES-W) |
- |
|
|
|
5.1-table 1 (DIMENSIONS AND TOLERANCES-H) |
- |
|
|
|
5.1-table 1 (DIMENSIONS AND TOLERANCES-W1) |
- |
|
|
|
5.1-table 1 (DIMENSIONS AND TOLERANCES-L2) |
- |
|
|
|
5.1-table 1 (DIMENSIONS AND TOLERANCES-L1) |
- |
|
|
|
5.1-table 1 (DIMENSIONS AND TOLERANCES-L3) |
- |
|
|
|
5.1-table 1 (DIMENSIONS AND TOLERANCES-T) |
- |
|
|
|
5.1-table 1 (DIMENSIONS AND TOLERANCES-D) |
- |
|
|
|
5.1-Table 2 (DIMENSIONS AND TOLERANCES-Connecting Dimensions-h1) |
- |
|
|
|
5.1-Table 2 (DIMENSIONS AND TOLERANCES-Connecting Dimensions-h2) |
- |
|
|
|
5.1-Table 2 (DIMENSIONS AND TOLERANCES-Connecting Dimensions-h3) |
- |
|
|
|
5.1-Table 2 (DIMENSIONS AND TOLERANCES-Connecting Dimensions-d1) |
- |
|
|
|
5.1-Table 2 (DIMENSIONS AND TOLERANCES-Connecting Dimensions-d2) |
- |
|
|
|
5.1-Table 2 (DIMENSIONS AND TOLERANCES-Connecting Dimensions-d3) |
- |
|
|
|
5.1-Table 2 (DIMENSIONS AND TOLERANCES-Connecting Dimensions-A) |
- |
|
|
|
5.1-Table 2 (DIMENSIONS AND TOLERANCES-Connecting Dimensions-B) |
- |
|
|
|
5.1-Table 2 (DIMENSIONS AND TOLERANCES-Connecting Dimensions-d4) |
- |
|
|
|
5.1-Table 2 (DIMENSIONS AND TOLERANCES-Connecting Dimensions-d5/2) |
- |
|
|
|
5.1-Table 2 (DIMENSIONS AND TOLERANCES-Connecting Dimensions-n) |
- |
|
|
|
5.1-Table 2 (DIMENSIONS AND TOLERANCES-Connecting Dimensions-M) |
- |
|
|
|
5.1-Table 2 (DIMENSIONS AND TOLERANCES-Connecting Dimensions-θ1) |
- |
|
|
|
5.1-Table 2 (DIMENSIONS AND TOLERANCES-Connecting Dimensions-θ2) |
- |
|
|
|
6.1 (CONSTRUCTION-closet) |
- |
|
|
|
6.1 (CONSTRUCTION-closet) |
- |
|
|
|
6.1 (CONSTRUCTION) |
- |
|
|
|
6.3-Table 3 (CONSTRUCTION-Dimensions of Two Piece Bend-d1) |
- |
|
|
|
6.3-Table 3 (CONSTRUCTION-Dimensions of Two Piece Bend-d2) |
- |
|
|
|
6.3-Table 3 (CONSTRUCTION-Dimensions of Two Piece Bend-d6) |
- |
|
|
|
6.3-Table 3 (CONSTRUCTION-Dimensions of Two Piece Bend-f) |
- |
|
|
|
6.3-Table 3 (CONSTRUCTION-Dimensions of Two Piece Bend-h) |
- |
|
|
|
7 (FINISH) |
- |
|
|
|
7 (FINISH) |
- |
|
|
|
9 (Load Bearing Test) |
- |
|
|
|
|
Partial
|
|
- |
- - |
460 |
IS 2556 : Part 2 (2004) |
Vitreous sanitary appliances (Vitreous China) - specification: Part 2 specific requirements of washdown water closets |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3 (General requirements-Permissible blemishes or defects (WC apns, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-General-Wavy finiah-IS 2556 (Part 1)) |
- |
|
|
|
4 (PATTERNS) |
- |
|
|
|
5 and Table 1
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - A) |
- |
|
|
|
5 and Table 1
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - H) |
- |
|
|
|
5 and Table 1
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - J) |
- |
|
|
|
5 and Table 1
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - K) |
- |
|
|
|
5 and Table 1
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - L) |
- |
|
|
|
5 and Table 1
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - O) |
- |
|
|
|
5 and Table 1
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - P) |
- |
|
|
|
5 and Table 1
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - Q) |
- |
|
|
|
5 and Table 1
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - S) |
- |
|
|
|
5 and Table 1
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - T) |
- |
|
|
|
5 and Table 1
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - W1) |
- |
|
|
|
5 and Table 1
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - W2) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - B) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - C1) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - C2) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - D) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - D1) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - D2) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - E) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - F) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - G) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - G1) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - G2) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - G3) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - M) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - N) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - R) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - R1) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - Ɵ) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - X) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - Y) |
- |
|
|
|
5 and Table 2
Fig. 1, 2 , 3 & 4 (DIMENSIONS AND TOLERANCES - Y1) |
- |
|
|
|
6.1 (CONSTRUCTION) |
- |
|
|
|
6.1 (CONSTRUCTION) |
- |
|
|
|
6.1 (CONSTRUCTION) |
- |
|
|
|
6.2 (CONSTRUCTION) |
- |
|
|
|
6.3 (CONSTRUCTION) |
- |
|
|
|
6.4 (CONSTRUCTION) |
- |
|
|
|
7 (FINISH) |
- |
|
|
|
|
Partial
|
|
- |
- - |
461 |
IS 7098 : Part 2 (2011) |
Crosslinked polyethylene insulated thermoplastic sheathed cables - Specification: Part 2 for working voltages from 3.3 kV up to and including 33 kV (Second Revision) |
- |
-
|
Rs. 33750/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (CONDUCTOR) |
- |
|
|
|
4.1.1 (CONDUCTOR) |
- |
|
|
|
5 (INSULATION) |
- |
|
|
|
6 (SCREENING) |
- |
|
|
|
6.1.1 (SCREENING : - Non-metallic — Semiconducting Compound) |
- |
|
|
|
6.1.2 (SCREENING : - Non-magnetic Metallic Tape for Single Core Unscreened and Unarmoured Cables) |
- |
|
|
|
7 (FILLERS AND INNER SHEATH) |
- |
|
|
|
8.1 (ARMOURING) |
- |
|
|
|
8.2 (ARMOURING) |
- |
|
|
|
9 (OUTER SHEATH ) |
- |
|
|
|
10.1 (CONDUCTOR) |
- |
|
|
|
10.2 (CONDUCTOR) |
- |
|
|
|
11 (CONDUCTOR SCREENING) |
- |
|
|
|
12.1 (INSULATION) |
- |
|
|
|
12.2 (INSULATION : Thickness of Insulation) |
- |
|
|
|
12.3 (INSULATION : Tolerance on Thickness of Insulation) |
- |
|
|
|
12.4 (Eccentricity and Ovality) |
- |
|
|
|
12.5 (INSULATION : Application of Insulation) |
- |
|
|
|
13.1 (INSULATION SCREENING) |
- |
|
|
|
13.2 (INSULATION SCREENING) |
- |
|
|
|
13.3 (INSULATION SCREENING) |
- |
|
|
|
13.4 (INSULATION SCREENING) |
- |
|
|
|
14.1 (CORE IDENTIFICATION) |
- |
|
|
|
15.1 (LAVING UP OF CORES) |
- |
|
|
|
16.1 (INNER SHEATH (COMMON COVERING)) |
- |
|
|
|
16.2 (INNER SHEATH (COMMON COVERING)) |
- |
|
|
|
16.2.1 (INNER SHEATH (COMMON COVERING)) |
- |
|
|
|
16.3 (INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
|
|
|
17.1 (ARMOURING : Application ) |
- |
|
|
|
17.1.1 (ARMOURING ) |
- |
|
|
|
17.1.2 (ARMOURING ) |
- |
|
|
|
17.1.3 (ARMOURING ) |
- |
|
|
|
17.2 (ARMOURING : Type of armour ) |
- |
|
|
|
17.2.1 (ARMOURING : Type of armour ) |
- |
|
|
|
17.2 (ARMOURING : Coverage ) |
- |
|
|
|
17.3 (ARMOURING : Dimension ) |
- |
|
|
|
17.4 (ARMOURING : Joints) |
- |
|
|
|
16.4 (ARMOURING : Resistance) |
- |
|
|
|
18.1 (OUTER SHEATH) |
- |
|
|
|
18.2 (OUTER SHEATH: Colour) |
- |
|
|
|
18.3 (Thicknes of outer sheath : average ) |
- |
|
|
|
18.3 (Thicknes of outer sheath : minimum ) |
- |
|
|
|
19.1 i) a) (Annealing test (for copper)) |
- |
|
|
|
19.1 i) b) (Tensile test (for aluminium) - Before stranding ) |
- |
|
|
|
19.1 i) b) (Tensile test (for aluminium) - After stranding ) |
- |
|
|
|
19.1 i) c) (Wrapping test ( for aluminium)) |
- |
|
|
|
19.1 i) d) (Resistance test - Main conductor ) |
- |
|
|
|
19.1 i) d) (Resistance test - Neutral conductor ) |
- |
|
|
|
19.1 iii) a) (Phyaical tests for insulation : Tensile Test) |
- |
|
|
|
19.1 iii) a) (Phyaical tests for insulation : Elongation ) |
- |
|
|
|
19.1 iii) b) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
|
|
|
19.1 iii) b) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
|
|
|
19.1 iii) d) (Phyaical tests for insulation : Hot set ) |
- |
|
|
|
19.1 iii) d) (Phyaical tests for insulation : Permanent set ) |
- |
|
|
|
19.1 iii) e) (Phyaical tests for insulation : Shrinkage ) |
- |
|
|
|
19.1 vi) a) (Physical tests for outer sheath : Tensile stregth ) |
- |
|
|
|
19.1 vi) a) (Physical tests for outer sheath : Elongation ) |
- |
|
|
|
19.1 vi) b) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
|
|
|
19.1 vi) b) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
|
|
|
19.1 vi) b) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
|
|
|
19.1 vi) b) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
|
|
|
19.1 vi) c) (Phyaical tests for Sheath : Shrinkage ) |
- |
|
|
|
19.1 vi) c) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
|
|
|
19.1 vi) d) (Sheath : Hot deformation) |
- |
|
|
|
19.1 vi) e) (Loss of massIn air oven) |
- |
|
|
|
19.1 vi) f) (Sheath : Heat shock test) |
- |
|
|
|
19.1 vi) g) (Sheath : Thermalstability) |
- |
|
|
|
19.1 xi) (Insulation resistance test : volume resistivity ) |
- |
|
|
|
20.8 (Flammability test) |
- |
|
|
|
20.7 (High voltage test) |
- |
|
|
|
21.1 (IDENTIFICATION : Manufacturer's Identification) |
- |
|
|
|
21.2 (IDENTIFICATION : Cable Identification) |
- |
|
|
|
21.3 (IDENTIFICATION : Cable Code) |
- |
|
|
|
Cl. 8 (Conductor) |
- |
|
|
|
Cl. 8 (Conductor) |
- |
|
|
|
Cl. 8 (Conductor) |
- |
|
|
|
Cl.8 & 17 (Armouring) |
- |
|
|
|
Cl.8 & 17 (Armouring : Tensile Strength) |
- |
|
|
|
Cl.8 & 17 (Armouring : Elongation) |
- |
|
|
|
Cl.8 & 17 (Armouring : Torsion Test (For Round Steel Wire Only)) |
- |
|
|
|
Cl.8 & 17 (Armouring: Winding Test ( For formed steel wire only)) |
- |
|
|
|
Cl.8 & 17 (Armouring : Application) |
- |
|
|
|
Cl.8 & 17 (Armouring : Uniformity of Zinc Coating) |
- |
|
|
|
Cl.8 & 17 (Armouring: Mass of Zinc Coating) |
- |
|
|
|
Cl.8 & 17 (Armouring : Resistivity Test) |
- |
|
|
|
Cl.8 & 17 (Armouring: Cold Impact Test (For outer Sheath)) |
- |
|
|
|
Cl. 13.5.1 and Table 7 (Armouring: Resistance Test for Armouring (Other than Mining Cables)) |
- |
|
|
|
|
Partial
|
|
- |
- EXCLUDING 1. Category C1/ C2 & 2.Thermal aging test for complete cable 19.9. 3. Partial discharge test 19.2 4. Bending test 19.3. 5. Dielectric power factor test: 19.4. a) As a function of voltage b) As a function of temperature 6. Insulation resistance (volume resistivity) test Table 1 43 7. Heat cycle test 19.5 49. 8. Impulse withstand test 19.6. 9.High voltage test |
462 |
IS 3831 (1979) |
Specification for sterilizer, shallow (Dressing Drum) |
- |
-
|
Rs 1200/- + Materials as per respective ISS View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
2 (Thickness of Body) |
- |
|
|
|
2 (Thickness of Lid) |
- |
|
|
|
2 (Thickness of Belt) |
- |
|
|
|
2 (Thickness of Hasp) |
- |
|
|
|
2 (Dia of Hinge Wire) |
- |
|
|
|
2 (Dia of Chain) |
- |
|
|
|
2 (Thickness of Clamp) |
- |
|
|
|
2 ( Dia of Handle) |
- |
|
|
|
3 & Fig 1 (Shape and Dimensions, A) |
- |
|
|
|
3 & Fig 1 (Shape and Dimensions, B) |
- |
|
|
|
3 & Fig 1 (Shape and Dimensions, C) |
- |
|
|
|
3 & Fig 1 (Shape and Dimensions, D) |
- |
|
|
|
3 & Fig 1 (Shape and Dimensions, E) |
- |
|
|
|
3 & Fig 1 (Shape and Dimension, Overall Dia) |
- |
|
|
|
3 & Fig 1 (Shape and Dimension, Overall Height) |
- |
|
|
|
3 & Fig 1 (Shape and Dimensions, N) |
- |
|
|
|
4.9.1 (Workmanship & Finish) |
- |
|
|
|
4.11 (Workmanship & Finish) |
- |
|
|
|
4.10 (Workmanship & Finish) |
- |
|
|
|
4.9 (Workmanship & Finish) |
- |
|
|
|
4.8 (Workmanship & Finish) |
- |
|
|
|
4.7 (Workmanship & Finish) |
- |
|
|
|
4.6 (Workmanship & Finish) |
- |
|
|
|
4.5 (Workmanship & Finish) |
- |
|
|
|
4.4 (Workmanship & Finish) |
- |
|
|
|
4.3 (Workmanship & Finish) |
- |
|
|
|
4.2 (Workmanship & Finish) |
- |
|
|
|
4.1 (Workmanship & Finish) |
- |
|
|
|
4 (Workmanship & Finish) |
- |
|
|
|
5 (Finish) |
- |
|
|
|
5 (Test) |
- |
|
|
|
Clause - 2 (CARBON) |
- |
|
|
|
Clause - 2 (SULPHUR) |
- |
|
|
|
Clause - 2 (PHOSPHURS) |
- |
|
|
|
Clause - 2 (MANGANESE) |
- |
|
|
|
Clause - 2 (NITROGEN) |
- |
|
|
|
Clause - 2 (SILICON) |
- |
|
|
|
Clause - 2 (CHROMIUM) |
- |
|
|
|
Clause - 2 (NICKEL) |
- |
|
|
|
|
Partial
|
|
- |
- - |
463 |
IS 3575 (1993) |
Bitumen drums - Specification (Third Revision) |
- |
-
|
- View breakup
Rs. 1800/- and Material testing charges as per relevant referred Iss
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (Dimensions Drums (Figure 1)) |
- |
|
|
|
4.1 (Dimensions Drums (Figure 1)) |
- |
|
|
|
4.1 (Dimensions Drums (Figure 1)) |
- |
|
|
|
4.1 (Dimensions Drums (Figure 1)) |
- |
|
|
|
4.1 (Dimensions Drums (Figure 1)) |
- |
|
|
|
4.1 (Dimensions Closure (Figure 2)) |
- |
|
|
|
4.1 (Dimensions Closure (Figure 2)) |
- |
|
|
|
4.1 (Dimensions Closure (Figure 2)) |
- |
|
|
|
4.1 (Dimensions Closure (Figure 2)) |
- |
|
|
|
6.1 (Construction) |
- |
|
|
|
6.2 (Construction) |
- |
|
|
|
6.3 (Construction) |
- |
|
|
|
6.4 (Construction) |
- |
|
|
|
6.5 (Closure) |
- |
|
|
|
7.1 (Finish) |
- |
|
|
|
7.2 (Finish) |
- |
|
|
|
8 (Air Pressure Test) |
- |
|
|
|
|
Partial
|
|
- |
- EXCLUDING 8 Air Pressure Test; |
464 |
IS 1825 (1983) |
Specification for aluminium alloy milk cans (Second Revision) |
- |
-
|
Rs 4800.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 Fig. 1 (Dimensions & Shape) |
- |
|
|
|
8 (a) Rated Capacity) |
- |
|
|
|
8 (c) Batch OR Code No.) |
- |
|
|
|
4 Fig. 1 (A) |
- |
|
|
|
4 Fig. 1 (B) |
- |
|
|
|
4 Fig. 1 (C ) |
- |
|
|
|
4 Fig. 1 (D) |
- |
|
|
|
4 Fig. 1 (E) |
- |
|
|
|
4 Fig. 1 (F) |
- |
|
|
|
4 Fig. 1 (G) |
- |
|
|
|
4 Fig. 1 (H) |
- |
|
|
|
4 Fig. 1 (HANDLE ) |
- |
|
|
|
5 (a)Transport cans shall consist of a body, bottom band) |
- |
|
|
|
5 (c) Mode of Shaping) |
- |
|
|
|
5 (i) If the thickness at shoulder is less than 2.5 mm a ) |
- |
|
|
|
5 (ii) Brinell Hardness 85 HB Min.) |
- |
|
|
|
5 (d) BOTTOM BAND- It shall be shrunk fit with a ) |
- |
|
|
|
5 (proper locking arrangement on the body. This shall) |
- |
|
|
|
5 (be followed by brazing or welding all round.) |
- |
|
|
|
5 (e) HANDLES (as per Cl 5.6)) |
- |
|
|
|
5 (g)Workmanship and Finish- All brazing or welding shall ) |
- |
|
|
|
5 (h) Mass 6.5 Kg. Min.) |
- |
|
|
|
7 (i) Air Pressure Test (Cl 7.1)) |
- |
|
|
|
7 (ii) Drop Test (Cl 7.2)) |
- |
|
|
|
7 (iii) The cans when filled with water and inverted shall not show any profuse leakage through lids. ) |
- |
|
|
|
|
Partial
|
|
- |
- EXCLUDING 7.2 Drop Test,; |
465 |
IS 458 (2003) |
Precast concrete pipes(With And Without Reinforcement) - Specification (Fourth Revision) |
- |
-
|
- View breakup
Rs.4200/- (excl. Split tensile strength test, Hydrostatic test, Three edge bearing test and test for aggregates) and testing charges as per relevant referred Iss
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8 &8.1,Table 1,i (Internal diameter of pipes.) |
- |
|
|
|
8 &8.1,Table 1,ii (Collar Dimension.) |
- |
|
|
|
8 &8.1,Table 1,iii (Minimum Length of Collar) |
- |
|
|
|
8 &8.1,Table 2,i (Internal diameter of pipes.) |
- |
|
|
|
8 &8.1,Table 2,ii (Barrel Wall Thickness) |
- |
|
|
|
8 &8.1,Table 2,iii (Reinforcement) |
- |
|
|
|
8 &8.1,Table 3,i (Internal diameter of pipes.) |
- |
|
|
|
8 &8.1,Table 3,ii (Barrel Wall Thickness) |
- |
|
|
|
8 &8.1,Table 3,iii (Reinforcement) |
- |
|
|
|
8 &8.1,Table 4,i (Internal diameter of pipes.) |
- |
|
|
|
8 &8.1,Table 4,ii (Minimum Barrel Wall Thickness) |
- |
|
|
|
|
Partial
|
|
- |
- - |
466 |
IS 1784 (2020) |
Screwed Closures for Drums — Specification ( Fourth Revision ) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (Materials) |
- |
|
|
|
5.1 (Manufacture-Bungs) |
- |
|
|
|
5.1 (Manufacture-Bungs) |
- |
|
|
|
5.1 (Manufacture-Bungs) |
- |
|
|
|
5.2 (Manufacture-Flange) |
- |
|
|
|
5.3 (Manufacture-Capseal ) |
- |
|
|
|
5.4 (Manufacture-Tag Ring) |
- |
|
|
|
6 (Dimensions-Steel flange- d1) |
- |
|
|
|
6 (Dimensions-Steel flange- d2) |
- |
|
|
|
6 (Dimensions-Steel flange- d3) |
- |
|
|
|
6 (Dimensions-Steel flange- d4) |
- |
|
|
|
6 (Dimensions-Steel flange- h1) |
- |
|
|
|
6 (Dimensions-Steel flange- s1) |
- |
|
|
|
6 (Dimensions-Steel flange- t1) |
- |
|
|
|
6 (Dimensions-Flange Gasket- wd) |
- |
|
|
|
6 (Dimensions-Flange Gasket-ww) |
- |
|
|
|
6 (Dimensions-Flange Gasket-wt) |
- |
|
|
|
6 (Dimensions-Steel Bung- d1) |
- |
|
|
|
6 (Dimensions-Steel Bung- p1) |
- |
|
|
|
6 (Dimensions-Steel Bung- p2) |
- |
|
|
|
6 (Dimensions-Steel Bung- p3) |
- |
|
|
|
6 (Dimensions- Bung Gasket- wd) |
- |
|
|
|
6 (Dimensions-Flange Gasket-ww) |
- |
|
|
|
6 (Dimensions-Flange Gasket-wt) |
- |
|
|
|
6 (Dimensions-Capseals- d1) |
- |
|
|
|
6 (Dimensions-Capseals- d2) |
- |
|
|
|
6 (Dimensions-Capseals- h1) |
- |
|
|
|
6 (Dimensions-Capseals- h2) |
- |
|
|
|
6 (Dimensions-Capseals- w1) |
- |
|
|
|
6 (Dimensions-Tag Ring- d1) |
- |
|
|
|
6 (Dimensions-Tag Ring- d2) |
- |
|
|
|
6 (Dimensions-Tag Ring- d3) |
- |
|
|
|
6 (Dimensions-Tag Ring- d4) |
- |
|
|
|
6 (Dimensions-Tag Ring- d5) |
- |
|
|
|
6 (Dimensions-Tag Ring- h1) |
- |
|
|
|
6 (Dimensions-Zinc Bung- d1) |
- |
|
|
|
6 (Dimensions-Zinc Bung- d2) |
- |
|
|
|
6 (Dimensions-Zinc Bung- d3) |
- |
|
|
|
6 (Dimensions-Zinc Bung- p1) |
- |
|
|
|
6 (Dimesnsions) |
- |
|
|
|
7 (Finish) |
- |
|
|
|
8.1 (Interchangeability) |
- |
|
|
|
8.2 (Air Pressure Test) |
- |
|
|
|
8.3.1 (Torque Test for Steel Bungs) |
- |
|
|
|
8.3.2 (Torque Test for Steel Bungs) |
- |
|
|
|
4 (Materials) |
- |
|
|
|
|
Partial
|
|
- |
- excluding 5.1.1 Thread Measurement, 8.2 Air Pressure Test, 8.3 Torque Test for Steel Bungs, 8.4 Curling Test for Flanges; |
467 |
IS 12640 : Part 2 (2016) |
Residual current operated circuit - Breakers with integral overcurrent protection for household and similar uses (Rcbos): Part 2 general rules |
- |
-
|
Rs. 10458.00 View breakup
Rs. 10458.00 (only for seq. A&B for Cl. 6, 8.1.2, 8.1.3, 9.3, 9.4, 9.5, 9.6, 9.7, 9.8, 9.13 & 9.14).
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1.3 (Clearances and creepage distances (internal parts)) |
- |
|
|
|
|
Partial
|
|
- |
- Facility available for seq. A&B except cl. 9.7.5, 9.7.6, 9.7.7, 9.11, 9.22, 9.23. No TF available for seq C, D, D1, E0, E, F0 |
468 |
IS 10228 (1982) |
Specification for school bag |
- |
-
|
Rs 2700/- + charges as per relevant ISS View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1 ( Dimensions-A) |
- |
|
|
|
3.1 (Dimensions-B) |
- |
|
|
|
3.1 (Dimensions-B1) |
- |
|
|
|
3.1 (Dimensions-C1) |
- |
|
|
|
3.1 (Dimensions-C2) |
- |
|
|
|
3.1 (Dimensions-C3) |
- |
|
|
|
3.1 (Dimensions-D) |
- |
|
|
|
3.1 (Dimensions-E) |
- |
|
|
|
3.1 (Dimensions-F) |
- |
|
|
|
3.1 (Dimensions-G) |
- |
|
|
|
3.1 (Dimensions-H) |
- |
|
|
|
3.1 (Dimensions-J) |
- |
|
|
|
3.1 (Dimensions-K) |
- |
|
|
|
3.1.1 (The length of back strap) |
- |
|
|
|
3.1.2 (The length of side strap) |
- |
|
|
|
5.1 (Manufacture, Workmanship & Finish) |
- |
|
|
|
5.2 (Manufacture, Workmanship & Finish) |
- |
|
|
|
5.3 (Manufacture, Workmanship & Finish) |
- |
|
|
|
5.4 (Manufacture, Workmanship & Finish) |
- |
|
|
|
5.4 (Manufacture, Workmanship & Finish) |
- |
|
|
|
5.5 (Manufacture, Workmanship & Finish) |
- |
|
|
|
5.5 (Manufacture, Workmanship & Finish) |
- |
|
|
|
5.6 (Manufacture, Workmanship & Finish) |
- |
|
|
|
7.1 ( Drop Test) |
- |
|
|
|
7.2 (Handle snatch test) |
- |
|
|
|
|
Complete
|
|
- |
- - |
469 |
IS 2465 (1984) |
Specification for cables for motor vehicles (Second Revision) |
- |
-
|
Single core PVC Insulated Unsheathed: Rs. 11030/- View breakup
Single core PVC Insulated Sheathed: 75 % additional for sheath. Multi core with PVC Sheath: 75% additional for each additional core. Round and flat tinned copper braids without further covering for earthing: Rs. 1115/- Above charges are excluding Material tests, Ageing in oxygen bomb, Capacitance test, Ozone resistance test, Effect of heat on flexibility, Effect of oils, Effect of lubricating oil, brake fluid, diesel and petrol, Effect of cooling on flexibility.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1 (Insulation) |
- |
|
|
|
7.3 (Insulation) |
- |
|
|
|
8 (Core Identification) |
- |
|
|
|
9 (Laying up of cores) |
- |
|
|
|
10.1.1 (Sheathing ) |
- |
|
|
|
10.2 (Sheathing ) |
- |
|
|
|
3 & 6 (Flexibility class) |
- |
|
|
|
3 & 6 (Construction) |
- |
|
|
|
3 & 6 (Diameter of wire(mm)) |
- |
|
|
|
3 & 6 (Annealing test) |
- |
|
|
|
3 & 6 (Conductor resistance Test (ohm/km at 20˚c)) |
- |
|
|
|
3 & 6 (Annealing test) |
- |
|
|
|
3 & 6 (Construction) |
- |
|
|
|
3 & 6 (Persulphate Test) |
- |
|
|
|
3 & 6 (Construction) |
- |
|
|
|
7.2, 10.3, 11 (Dimensions & thickness ) |
- |
|
|
|
7.2, 10.3, 11 (Dimensions & thickness ) |
- |
|
|
|
7.2, 10.3, 11 (Overall Dimension (mm)) |
- |
|
|
|
4.2 & 12.1 (Without Ageing For Insulation
Tensile Strength (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (f), 1 (elongation at break (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (f), 1 (Tensile Strength at break (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (e), 1 (elongation test at break) |
- |
|
|
|
4.2 & 12.1, (e), 2 (After Ageing in air oven) |
- |
|
|
|
4.2 & 12.1, (e), 1 (elongation test at break) |
- |
|
|
|
4.2 & 12.1, (f), 1 (elongation at break (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (f), 1 (Tensile Strength at break (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (e), 3 (Loss of mass test (mg/cm²) of Sheath) |
- |
|
|
|
4.2 & 12.1, (f), 1 (Tensile Strength at break (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (e), 3 (Loss of mass test (mg/cm²) of Sheath) |
- |
|
|
|
4.2 & 12.1, (f), 1 (Tensile Strength at break (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (f), 1 (elongation at break (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (f), 1 (Tensile Strength at break (N/mm²)) |
- |
|
|
|
4.2 & 12.1 (Without Ageing For Insulation
Tensile Strength (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (f), 1 (elongation at break (N/mm²)) |
- |
|
|
|
14 (High Voltage Test) |
- |
|
|
|
23.1 (Manufacturer's Identification) |
- |
|
|
|
23.1 (Manufacturer's Identification) |
- |
|
|
|
24.1 (PACKING AND MARKING) |
- |
|
|
|
24.2 (PACKING AND MARKING) |
- |
|
|
|
24.2.1 (PACKING AND MARKING) |
- |
|
|
|
4.2 & 12.1, (f), 3 (Ageing in oxygen bomb) |
- |
|
|
|
20.3 (EFFECT OF LUBRICATING OIL) |
- |
|
|
|
20.3 (EFFECT OF LUBRICATING OIL) |
- |
|
|
|
20.3 (EFFECT OF BRAKE FLUID) |
- |
|
|
|
20.3 (EFFECT OF BRAKE FLUID) |
- |
|
|
|
20.3 (EFFECT OF DIESEL) |
- |
|
|
|
20.3 (EFFECT OF DIESEL) |
- |
|
|
|
20.3 (Increase in average diameter %) |
- |
|
|
|
20.3 (Wrapping test) |
- |
|
|
|
22.1 (FLAMMABILITY TEST) |
- |
|
|
|
22.1 (FLAMMABILITY TEST) |
- |
|
|
|
CL.12.1 (e) 2 (Tensile Strength After Ageing) |
- |
|
|
|
CL.12.1 (e) 2 (Elongation After Ageing) |
- |
|
|
|
CL.12.1 (e) 2 (Tensile Strength Variation) |
- |
|
|
|
CL.12.1 (e) 2 (Elongation Variation) |
- |
|
|
|
CL.12.1 (e) 2 (Elongation Variation) |
- |
|
|
|
Cl.12 (e) 5 (Heat shock test) |
- |
|
|
|
Cl.12 (e) 4 (Hot Deformation Test) |
- |
|
|
|
Cl.12 (e) 6 (Shrinkage Test) |
- |
|
|
|
Cl.12 (e) 6 (Shrinkage Test (Cracks Observed)) |
- |
|
|
|
Cl. 12.1 (e) 3 (Loss of Mass Insulation) |
- |
|
|
|
|
Partial
|
|
- |
- TF Partial for Ignition cables of elastomer and PVC insulation; TF not avail. for High Voltage, Capacitance, Ozone resistance, Effect of heating on flexibility, Effect of Oil tests & Effect of cooling on flexibility (optional) |
470 |
IS 6149 (1984) |
Specification for single - Ended open - Jaw adjustable wrenches (First Revision) |
- |
-
|
- View breakup
Rs.2100/- and material testing charges as per relevant referred ISs.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
2 (Type) |
- |
|
|
|
3 (Grades) |
- |
|
|
|
4 Table-1 (Dimensions- Nominal Size) |
- |
|
|
|
4 Table-1 (Dimensions- l) |
- |
|
|
|
4 Table-1 (Dimensions- s) |
- |
|
|
|
4 Table-1 (Dimensions- a) |
- |
|
|
|
4 Table-1 (Dimensions- b) |
- |
|
|
|
4 Table-1 (Dimensions- t) |
- |
|
|
|
4 Table-1 (Dimensions- d) |
- |
|
|
|
4 Table-1 (Dimensions- Opening of adjustable jaws) |
- |
|
|
|
6 (Hardness- Frame, handle and Jaw) |
- |
|
|
|
6 (Hardness- Worm) |
- |
|
|
|
6 (Hardness- Worm pin) |
- |
|
|
|
7 (Manufacture,Workmanship & Finish) |
- |
|
|
|
8 (Longitudinal Play of Adjustable Jaw) |
- |
|
|
|
8 (Transverse Play of Adjustable Jaw) |
- |
|
|
|
8 (Torque) |
- |
|
|
|
|
Partial
|
|
- |
- - |
471 |
IS 302 : Part 2 : Sec 201 (2008) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 201 electric immersion water heaters (First Revision) |
- |
-
|
Rs 6900/ View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6 of IS 302-‐2-‐201:2008 (Classification) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.8 of IS 302‐2-201: 2008 (Protection Against Access to Live Parts) |
- |
|
|
|
Cl.10 of IS 302‐2‐201:2008 (Power Input and Current ) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.13 of IS 302-2-201: 2008 (Leakage Current & Electric Strength at Operating Temperature) |
- |
|
|
|
Cl.15 of IS 302-2-201:2008 (Moisture Resistance ) |
- |
|
|
|
Cl.15 of IS 302-2-201:2008 (Moisture Resistance ) |
- |
|
|
|
Cl.16 of IS 302-2-201:2008 (Leakage Current & Electric Strength) |
- |
|
|
|
Cl.19 of IS 302‐2-201: 2008 (Abnormal Operation ) |
- |
|
|
|
Cl.19 of IS 302‐2-201: 2008 (Abnormal Operation ) |
- |
|
|
|
Cl.19 of IS 302‐2-201: 2008 (Abnormal Operation ) |
- |
|
|
|
Cl.19 of IS 302‐2-201: 2008 (Abnormal Operation ) |
- |
|
|
|
Cl.20 of IS 302-2-201: 2008 (Stability & Mechanical Hazards) |
- |
|
|
|
Cl.21 of IS 302-2-201: 2008 (Mechanical Strength ) |
- |
|
|
|
Cl.21 of IS 302-2-201: 2008 (Mechanical Strength ) |
- |
|
|
|
Cl.21 of IS 302-2-201: 2008 (Mechanical Strength ) |
- |
|
|
|
Cl.22 of IS 302-2-201: 2008 (Construction) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.26 of IS 302-2-201: 2008 (Terminals for External Conductors) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.28 of IS 302-2-201: 2008 (Screws & Connections ) |
- |
|
|
|
Cl.29 of IS 302-2‐201:2008 (Clearances, Creepage Distances and Solid Insulation ) |
- |
|
|
|
Cl.30 of IS 302-2‐201:2008 (Resistance to Heat and Fire ) |
- |
|
|
|
Cl.31 of IS 302-2-201:2008 (Resistance of Rusting ) |
- |
|
|
|
Cl.32 of IS 302-2-201:2008 (Radiation, Toxicity and Similar Hazards) |
- |
|
|
|
|
Partial
|
|
- |
- Exclusion electronic circuit type appliances(Cl.19.11 of IS 302 part 1) |
472 |
IS 4508 (1992) |
Open ended slugging wrenches (Spanners) - specification (First Revision) |
- |
-
|
Rs.1550.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3 (Dimensions- s) |
- |
|
|
|
3 (Dimensions- a) |
- |
|
|
|
3 (Dimensions- b) |
- |
|
|
|
3 (Dimensions- l) |
- |
|
|
|
5 (Hardness) |
- |
|
|
|
6 (Workmanship and Finish) |
- |
|
|
|
7 (PRESERVATION AND PACKING) |
- |
|
|
|
9 (Designation) |
- |
|
|
|
|
Complete
|
|
- |
- Sample size shall be minimum dia> 3mm and thickness > 0.8 mm; |
473 |
IS 12640 : Part 1 (2016) |
Residual current operated circuitBreakers without integral overcurrent protection for household and similar uses (Rccbs): Part 1 general rules (Second Revision) |
- |
-
|
Rs. 10458.00 View breakup
Rs. 10458.00 (only for seq. A&B for Cl. 6, 8.1.2, 8.1.3, 9.3, 9.4, 9.5, 9.6, 9.7, 9.8, 9.13 & 9.14).
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
6 (Marking) |
- |
|
|
|
8.1.1 (General) |
- |
|
|
|
8.1.2 (Mechanism) |
- |
|
|
|
8.1.2 (Mechanism) |
- |
|
|
|
8.1.2 (Mechanism) |
- |
|
|
|
8.1.2 (Mechanism) |
- |
|
|
|
8.1.2 (Mechanism) |
- |
|
|
|
8.1.2 (Mechanism) |
- |
|
|
|
8.1.2 (Mechanism) |
- |
|
|
|
8.1.3 i) (Clearance ) |
- |
|
|
|
8.1.3 (Creepage distances) |
- |
|
|
|
9.4 (Test of reliability of screws, current carrying parts and connections ) |
- |
|
|
|
9.5 (Test of reliability of terminals
for external conductors) |
- |
|
|
|
9.6 (Protection against electric shock) |
- |
|
|
|
9.13 (Test of resistance to heat) |
- |
|
|
|
9.7.1 (Dielectric Properties : Resistance to humidity) |
- |
|
|
|
9.7.2 (Insulation resistance of main circuit) |
- |
|
|
|
9.7.1 (Dielectric Properties : Resistance to humidity) |
- |
|
|
|
9.8 (Test of Temperature rise) |
- |
|
|
|
|
Partial
|
|
- |
- Testing facility not available for 1. Trip free mechanism, 2. Resistance of insulation against impulse voltage, 3. Reliability at 40 °C 4. Aging of electric components, 5. Mechanical and electrical endurance 6. Test sequence D 7. Test sequence E 8. Test sequence F, 9. Test sequence G, 10. Verification of the suitability of RCCB for use in IT system |
474 |
IS 1258 (2005) |
Bayonet lamp holders (Fourth Revision) |
- |
-
|
- View breakup
"Hence complete testing charges for the products are: 23 X 300 +830 X 9 = Rs.14370/-for Ordinary lamp holder,
Rs.3150/-additional testing charges for Drip proof lamp holder,
Rs.1200.00 additional testing charges for Switched lamp holder,
Rs.610.00 additional testing charges for Tracking test on other than ordinary lamp holder.
Rs 1200.00additional testing charges for T1, T2 marked lamp holder."
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1 (Marking ) |
- |
|
|
|
8.2 (Marking ) |
- |
|
|
|
8.3 (Marking ) |
- |
|
|
|
8.4 (Marking ) |
- |
|
|
|
8.5 (Marking ) |
- |
|
|
|
8.6 (Marking ) |
- |
|
|
|
8.7 (Marking ) |
- |
|
|
|
8.8 (Marking ) |
- |
|
|
|
6 (Rating ) |
- |
|
|
|
6 (Rating ) |
- |
|
|
|
7 (Classification) |
- |
|
|
|
7.2 (Classification) |
- |
|
|
|
7.3 (Classification) |
- |
|
|
|
7.4 (Classification) |
- |
|
|
|
7.5 (Classification) |
- |
|
|
|
7.6 (Classification) |
- |
|
|
|
9.1 (Dimensions) |
- |
|
|
|
9.1 (Dimensions) |
- |
|
|
|
9.1 (Dimensions) |
- |
|
|
|
9.1 (Dimensions) |
- |
|
|
|
9.1 (Dimensions) |
- |
|
|
|
9.1 (Dimensions) |
- |
|
|
|
9.1 (Dimensions) |
- |
|
|
|
9.1 (Dimensions) |
- |
|
|
|
9.2 (Dimensions) |
- |
|
|
|
9.3 (Dimensions) |
- |
|
|
|
10 (Protection against electric shock ) |
- |
|
|
|
11.1 (Terminals) |
- |
|
|
|
11.2 (Terminals) |
- |
|
|
|
11.3 (Terminals) |
- |
|
|
|
11.4 (Terminals) |
- |
|
|
|
12 (Provision for Earthing) |
- |
|
|
|
13.1 (Construction) |
- |
|
|
|
13.1 (Construction) |
- |
|
|
|
13.1 (Construction) |
- |
|
|
|
13.2 (Construction (Data Sheet No 7005-10& 7006-15A)) |
- |
|
|
|
13.3 (Construction ) |
- |
|
|
|
13.4 (Construction ) |
- |
|
|
|
13.5 (Construction) |
- |
|
|
|
13.2 ,13.6 & 13.7 (Construction) |
- |
|
|
|
13.2 ,13.6 & 13.8 (Construction) |
- |
|
|
|
13.11 (Construction) |
- |
|
|
|
14 (Construction) |
- |
|
|
|
15.1 (Moisture Resistance, Insulation Resistance and Electric Strength) |
- |
|
|
|
15.2 (Moisture Resistance, Insulation Resistance and Electric Strength) |
- |
|
|
|
15.3 (Moisture Resistance, Insulation Resistance and Electric Strength) |
- |
|
|
|
16.1 (Mechanical Strength) |
- |
|
|
|
16.1 (Mechanical Strength) |
- |
|
|
|
16.2 (Mechanical Strength) |
- |
|
|
|
16.3 (Mechanical Strength) |
- |
|
|
|
16.4 (Mechanical Strength) |
- |
|
|
|
16.5 (Mechanical Strength) |
- |
|
|
|
16.6 & Table - 6 (Mechanical Strength) |
- |
|
|
|
16.7 (Mechanical Strength) |
- |
|
|
|
16.8 (Mechanical Strength) |
- |
|
|
|
17 (Screws,current-carrying parts and connections) |
- |
|
|
|
18 (Creepage distances and Clearances) |
- |
|
|
|
18.1, Table 8 (Creepage distances and Clearances) |
- |
|
|
|
18.1, Table 8 (Creepage distances and Clearances) |
- |
|
|
|
18.1, Table 8 (Creepage distances and Clearances) |
- |
|
|
|
19.1 (General resistance to heat) |
- |
|
|
|
19.2 (General resistance to heat) |
- |
|
|
|
19.3 (General resistance to heat) |
- |
|
|
|
19.4 (Resistance to heat test) |
- |
|
|
|
20.1 (Resistance to heat, fire and tracking) |
- |
|
|
|
20.3 (Resistance to heat, fire and tracking) |
- |
|
|
|
20.4 (Resistance to heat, fire and tracking) |
- |
|
|
|
20.5 (Resistance to tracking) |
- |
|
|
|
21.1 (Resistance to excessive residual stresses and to rusting) |
- |
|
|
|
|
Partial
|
|
- |
- Testing facility not available for Mechanical strength test on matel plate lamp holder. |
475 |
IS 14899 (2014) |
Liquefied petroleum gas (LPG) containers for automotive use - Specification (First Revision) |
- |
-
|
- View breakup
Rs. 21363/- (excluding Out of roundness, Hardness test, Pneumatic test, Radiographic examination, Bonfire test, Crash test and Strength assessment) + testing charges as per referred ISS.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
10.1.5 (Inner surface in tension) |
- |
|
|
|
10.1.5 (Outer surface in tension) |
- |
|
|
|
10.1.6 (Macroscopic Examination On Circumferential Weld ) |
- |
|
|
|
10.1.6 (Macroscopic Examination On longitudinal Weld) |
- |
|
|
|
10.1.6.1 (Macroscopic Examination, m1,Through valve boss ) |
- |
|
|
|
10.1.6.1 (Macroscopic Examination, m2,Through valve plate welds) |
- |
|
|
|
10.1.8 (Water Capacity) |
- |
|
|
|
10.2.1 (Hydrostatic stretch test) |
- |
|
|
|
10.2.2 (Burst test) |
- |
|
|
|
10.2.3.2 (Change in volume,) |
- |
|
|
|
10.2.3.3 (shall not cause any fragmentation ) |
- |
|
|
|
10.3 (Hydrostatic Test,3 MPa for 60 seconds ) |
- |
|
|
|
10.6.2 (Fatigue Test) |
- |
|
|
|
11 (Surface coating and colour) |
- |
|
|
|
10.1 (Macroscopic Examination) |
- |
|
|
|
10.3 (Hydrostatic Test,3 MPa for 60 seconds ) |
- |
|
|
|
|
Partial
|
|
- |
- Excluding -; Circumferential Weld (Cl 7.2.2.2),Out of Roundness (Cl 7.3)Hydrostatic Stretch Test (Cl 10.2.1)Pneumatic Leakage Test (Cl 10.4)Bonfire Test (Cl 10.6.1)Radiographic Examination (Cl 10.5.1)Radiographic Examination (Cl 10.5.1)Bonfire Test (Cl 10.6.1)Fatigue Test (Cl 10.6.2)Crash Test (Cl 10.6.3)Strength Assessment (Cl 10.6.4) |
476 |
IS 8978 (1992) |
Specification for electric instantaneous water heaters (Second Revision) |
- |
-
|
Rs.15030/ View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6 of IS 302-2-35:2017 (Classification) |
- |
|
|
|
Cl.6 of IS 302-2-35:2017 (Classification) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.8 of IS 302-2-35:2017 (Protection Against Access To Live Parts) |
- |
|
|
|
Cl.10 of IS 302-2- 35:2011 (Power Input & Current ) |
- |
|
|
|
Cl.11 of 302-2-35:2017 (Heating) |
- |
|
|
|
Cl.11 of 302-2-35:2017 (Heating) |
- |
|
|
|
Cl.11 of 302-2-35:2017 (Heating) |
- |
|
|
|
Cl.11 of 302-2-35:2017 (Heating) |
- |
|
|
|
Cl.13 of IS 302-2-35:2017 (Leakage Current & Electrical Strength at Operating Temperature ) |
- |
|
|
|
Cl.13 of IS 302-2-35:2017 (Leakage Current & Electrical Strength at Operating Temperature ) |
- |
|
|
|
Cl.15 of IS 302-2-35-2011 (Moisture Resistance ) |
- |
|
|
|
Cl.15 of IS 302-2-35-2011 (Moisture Resistance ) |
- |
|
|
|
Cl.16 of IS 302-2-35:2011 (Leakage Current and Electric Strength) |
- |
|
|
|
Cl.16 of IS 302-2-35:2011 (Leakage Current and Electric Strength) |
- |
|
|
|
Cl.19 of IS 302-2-35:2017 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-35:2017 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-35:2017 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-35:2017 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-35:2017 (Abnormal Operation) |
- |
|
|
|
Cl.20 of IS 302-2-35-2011 (Stability & Mechanical Hazards
) |
- |
|
|
|
Cl.21.1 of IS 302-2-35-2011 (Mechanical strength) |
- |
|
|
|
Cl. 21.2 of IS 302-1:2008 (Mechanical strength) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.27 of IS 302-2-35:2017 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 302-2-35:2017 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 302-2-35:2017 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 302-2-35:2017 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 302-2-35:2017 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 302-2-35:2017 (Provision for Earthing) |
- |
|
|
|
Cl.28 of IS 302-2-35:2017 (Screws and Connections
) |
- |
|
|
|
Cl.29 of IS 302-2-35:2017 (Clearances, Creepage Distances and Solid Insulation) |
- |
|
|
|
Cl.29 of IS 302-2-35:2017 (Clearances, Creepage Distances and Solid Insulation) |
- |
|
|
|
Cl.30 of IS 302-2-35: 2011 (Resistance to Heat and Fire) |
- |
|
|
|
Cl.30 of IS 302-2-35: 2011 (Resistance to Heat and Fire) |
- |
|
|
|
Cl.31 of IS 302-2-35: 2011 (Resistance to Rusting
) |
- |
|
|
|
Cl.32 of IS 302-2-35: 2011 (Radiation, Toxicity and Similar Hazards
) |
- |
|
|
|
Cl.10 of IS 8978 : 1992 (Finish) |
- |
|
|
|
Cl.11 of IS 8978 : 1992 (Operation of flow switch) |
- |
|
|
|
Cl.12 of IS 8978 : 1992 (Endurance) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7.1 of IS 302-2-35:2017 (Marking : rated pressure) |
- |
|
|
|
Cl.7.101 of IS 302-2-35:2017 (Marking : Woter inlet and outlet idetification) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.23 of IS 302-2-35-2011 (Internal Wiring) |
- |
|
|
|
Cl.24 of IS 302-2-35:2017 (Component
) |
- |
|
|
|
Cl.25.8 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords : Resistance of supply cord ) |
- |
|
|
|
Cl.27.5 of IS 302-2-35:2017 (Provision for Earthing : ECR ) |
- |
|
|
|
|
Partial
|
|
- |
- Complete except electronic circuit type appliances(IS 302-2-21, IS 302-1) |
477 |
IS 14846 (2000) |
Sluice valve for water works purposes (50 To 1200 mm size) - specification |
- |
-
|
complete testing charges for the product are Rs.5700.00 View breakup
complete testing charges for the product are Rs.5700.00
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (Nominal Pressures) |
- |
|
|
|
5.1 (Nominal Sizes) |
- |
|
|
|
5.1.1 (Actual Bore) |
- |
|
|
|
7.2.2 (Manufacture - Bodies and Bonnets) |
- |
|
|
|
7.2.3 (Manufacture) |
- |
|
|
|
7.2.4 (Manufacture) |
- |
|
|
|
7.3 Table 3A 1 (Flanges) |
- |
|
|
|
7.3 Table 3A 2 (Flanges) |
- |
|
|
|
7.3 Table 3A 3 (Flanges) |
- |
|
|
|
7.3 Table 3A 4 (Flanges) |
- |
|
|
|
7.3 Table 3A 5 (Flanges) |
- |
|
|
|
7.3 Table 3A 6 (Flanges) |
- |
|
|
|
7.4.1 (Wedges ) |
- |
|
|
|
7.4.1 (Wedges) |
- |
|
|
|
7.5 (Guides and Lugs) |
- |
|
|
|
7.5 (Guides and Lugs) |
- |
|
|
|
7.5.1 (Guides and Lugs) |
- |
|
|
|
7.6 Table 4 (Facing or Seat Rings) |
- |
|
|
|
7.6 Table 4 (Facing or Seat Rings) |
- |
|
|
|
7.6 Table 4 (Facing or Seat Rings) |
- |
|
|
|
7.6 Table 4 (Facing or Seat Rings) |
- |
|
|
|
7.7.1 Table 2,3 (Dimension of Stem and Wedge Nuts) |
- |
|
|
|
7.7.1 Table 2,3 (Dimension of Stem and Wedge Nuts) |
- |
|
|
|
7.7.1 Table 2,3 (Dimension of Stem and Wedge Nuts) |
- |
|
|
|
7.7.1 Table 2,3 (Dimension of Stem and Wedge Nuts) |
- |
|
|
|
7.7.1 Table 2,5 (Dimension of Stem and Wedge Nuts) |
- |
|
|
|
7.7.2 (Stem and Wedge Nuts) |
- |
|
|
|
7.7.3 (Stem and Wedge Nuts) |
- |
|
|
|
7.7.4 (Stem and Wedge Nuts) |
- |
|
|
|
7.9 (Height of Valve) |
- |
|
|
|
7.1 (Gears) |
- |
|
|
|
7.11 (Hand Wheel) |
- |
|
|
|
7.11 (Hand Wheel) |
- |
|
|
|
7.11 (Hand Wheel) |
- |
|
|
|
7.12 (Valve Caps) |
- |
|
|
|
7.12 (Valve Caps) |
- |
|
|
|
7.12 (Valve Caps) |
- |
|
|
|
7.13 Table 2, 3 (Stuffing Box ) |
- |
|
|
|
7.13 Table 2, 3 (Stuffing Box ) |
- |
|
|
|
7.13 Table 2, 3 (Stuffing Box ) |
- |
|
|
|
7.13 Table 2, 3 (Stuffing Box ) |
- |
|
|
|
7.14 (By Pass Arrangements) |
- |
|
|
|
7.14 (By Pass Arrangements) |
- |
|
|
|
8 (Accessories or Optical Features) |
- |
|
|
|
9 (Coating) |
- |
|
|
|
Cl.6, Table-1 (CARBON) |
- |
|
|
|
Cl.6, Table-1 (SULPHUR) |
- |
|
|
|
Cl.6, Table-1 (PHOSPHURS) |
- |
|
|
|
Cl.6, Table-1 (MANGANESE) |
- |
|
|
|
Cl.6, Table-1 (SILICON) |
- |
|
|
|
Cl.6, Table-1 (ALUMINIUM) |
- |
|
|
|
Cl.6, Table-1 (NITROGEN) |
- |
|
|
|
Cl.6, Table-1 (CHROMIUM) |
- |
|
|
|
Cl.6, Table-1 (NIOBIUM) |
- |
|
|
|
Cl.6, Table-1 (NICKEL) |
- |
|
|
|
Cl.6, Table-1 (VANADIUM) |
- |
|
|
|
Cl.6, Table-1 (TITANIUM) |
- |
|
|
|
Cl.6, Table-1 (MOLYBDENUM) |
- |
|
|
|
Cl.6, Table-1 (ZINC) |
- |
|
|
|
Cl.6, Table-1 (CADMIUM) |
- |
|
|
|
Cl.6, Table-1 (IRON) |
- |
|
|
|
Cl.6, Table-1 (TIN) |
- |
|
|
|
Cl.6, Table-1 (COPPER) |
- |
|
|
|
Cl.6, Table-1 (INDIUM) |
- |
|
|
|
Cl.6, Table-1 (TOTAL IMPURITIES) |
- |
|
|
|
|
Partial
|
|
- |
- -; Complete (up to 200 mm size) |
478 |
IS 3725 (1966) |
Specification for resistance wires, tapes and strips for heating flements |
- |
-
|
Rs 1500.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (Physical Condition, IS 3725) |
- |
|
|
|
4.2 (Physical Dimensions, IS 3725) |
- |
|
|
|
4.2 (Physical Dimensions, IS 3725) |
- |
|
|
|
4.4 (Physical and Mechanical Properties, IS 3725) |
- |
|
|
|
4.4.1 (Physical and Mechanical Properties, IS 3725) |
- |
|
|
|
4.4.2 (Physical and Mechanical Properties, IS 3725) |
- |
|
|
|
4.4.3 (Physical and Mechanical Properties, IS 3725) |
- |
|
|
|
4.5 (Tensile Properties, IS 3725) |
- |
|
|
|
4.5 (Tensile Properties, IS 3725) |
- |
|
|
|
5.1 (Resistance, IS 3725) |
- |
|
|
|
5.2 (Uniformity of Resistance, IS 3725) |
- |
|
|
|
5.2.1 (Uniformity of Resistance, IS 3725) |
- |
|
|
|
7.3.1 (Wrapping Test- Round wire, IS 3725) |
- |
|
|
|
7.3.2 (Wrapping Test- Strips and tapes, IS 3725) |
- |
|
|
|
6.1 (Marking, IS 3725) |
- |
|
|
|
6.1 (Marking, IS 3725) |
- |
|
|
|
6.1 (Marking, IS 3725) |
- |
|
|
|
6.1 (Marking, IS 3725) |
- |
|
|
|
6.1 (Marking, IS 3725) |
- |
|
|
|
6.1 (Marking, IS 3725) |
- |
|
|
|
6.1 (Marking, IS 3725) |
- |
|
|
|
6.1 (Marking, IS 3725) |
- |
|
|
|
6.1.1 (Marking, IS 3725) |
- |
|
|
|
6.2 (Packing, IS 3725) |
- |
|
|
|
|
Partial
|
|
- |
- Excluding Endurance Test; |
479 |
IS 15652 (2006) |
Insulating mats for electrical purposes - Specification |
- |
-
|
- View breakup
Rs. 11220/- excluding Di-electric properties, Thermal properties and Extreme low temperature.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9 (Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
|
|
|
9 (Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
|
|
|
9 (Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
|
|
|
9 (Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
|
|
|
9 (Marking (As per Cl.9.2 of IS 15652 : 2006)) |
- |
|
|
|
10.a) (Packing) |
- |
|
|
|
10.b) (Packing) |
- |
|
|
|
10.c) (Packing) |
- |
|
|
|
4 (Classification and Designation (As per Cl.4.1 and Table-1 of IS 15652 : 2006)) |
- |
|
|
|
4 (Classification and Designation (As per Cl.4.2 of IS 15652 : 2006)) |
- |
|
|
|
4 (Classification and Designation (As per Cl.4.2 of IS 15652 : 2006)) |
- |
|
|
|
5 (Composition (As per Cl. 5.1 of IS 15652 : 2006)) |
- |
|
|
|
5 (Composition (As per Cl. 5.2 of IS 15652 : 2006)) |
- |
|
|
|
6 (Shape Requirements and Dimension (As per Cl.6.1 & 6.2 of IS 15652 : 2006)) |
- |
|
|
|
6 (Shape Requirements and Dimension (As per Cl.6.1 & 6.2 of IS 15652 : 2006)) |
- |
|
|
|
6 (Thickness [mm] (As per Cl. 6.3 and Table-2 of IS 15652 : 2006)) |
- |
|
|
|
6 (Colour (As per Cl. 6.4 of IS 15652 : 2006)) |
- |
|
|
|
7 (Workmanship & Finish (As per Cl. 7.1 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.1 and Table - 3 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.1 and Table - 3 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.3 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.3 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
|
|
|
8 (Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
|
|
|
|
Partial
|
|
- |
- Excluding Die Electric Properties / Thermal properties / Extreme Low Temperature Test; |
480 |
IS 3745 (2006) |
Yoke type valve connections for small medical gas cylinders - Specification (Second Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.2.1 i) (i)Tensile Strength ) |
- |
|
|
|
3.2.1 ii) ( Elongation) |
- |
|
|
|
3.2.2 (The izod impact strength) |
- |
|
|
|
5.1.2 (Stress Corrosion Testfor Copper Alloy Valve Bodies ) |
- |
|
|
|
5.3.1 (Types of ‘Valves and their Minimum Constructional Requirements) |
- |
|
|
|
5.3.3 (Types of ‘Valves and their Minimum Constructional Requirements) |
- |
|
|
|
5.3.4 (Types of ‘Valves and their Minimum Constructional Requirements) |
- |
|
|
|
5.3.6 (Types of ‘Valves and their Minimum Constructional Requirements) |
- |
|
|
|
6.1 Fig, 2 (BASIC “DIMENS1ONS FOR YOKE TYPE VALVE CONNECTIONS) |
- |
|
|
|
6.2 , Fig. 3. (BASIC “DIMENS1ONS FOR YOKE TYPE VALVE CONNECTIONS) |
- |
|
|
|
10 (HYDROSTATIC TESTS) |
- |
|
|
|
|
Partial
|
|
- |
- Excluding -; TF not available for Cr plating and Cycle test |