BIS, Eastern Regional Laboratory (ERL)

(1) Annex Building & Sample-Cell: Bureau of Indian Standards, P-230, CIT Scheme, VII- M, Block-W,Kankurgachi,Kolkata-700054 (2) Main building: 1/14, CIT Scheme VII M, VIP Road, Kankurgachi,Kolkata-700054, Kolkata, Kolkata, West Bengal, 700054
- sample.erol@bis.gov.in
Scope List
Reset
364 Results
S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
331 IS 1489 : Part 2 (2015) Portland - Pozzolana cement - Specification: Part 2 calcined clay based - Rs.8420/- View breakup
-
- -
Mech-Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement (as per Table 1) and declaration of fly ash content & Confirmation for testing Alkali Content required.
332 IS 278 (2009) Galvanized steel barbed wire for fencing - Specification (Fourth Revision) For all varietiesexcept tests mentioned in remarks - View breakup
-
- -
Mech- Complete. 3 mtr point wire to be provided additionally.. Chem- Facility not available for Al (when Al- killed). Also see status for IS 7887
333 IS 191 (2007) Copper - Specification (Fourth Revision) All - View breakup
-
- -
Chem-Only Cu purity test can be carried out, Complete Test Facilities for Electrical Test
334 IS 1566 (1982) Specification for hard - Drawn steel wire fabric for concrete reinforcement (Second Revision) all grades Rs 300/- + mat test as per IS:432(Pt 2) View breakup
-
- -
Chem- Except Microalloys & Al tests.
335 IS 12776 (2002) Galvanized strand for earthing - Specification (First Revision) All sizes/grades (pl see remarks) Rs.3470 View breakup
-
- -
Except Breaking Load of Complete wire. "Declarations Required: Size & Tensile Grade".5 mtr sample (before stranding) to be provided additionally.
336 IS 3975 (1999) Low carbon galvanized steel wires, formed wires and tapes for armouring of cables - Specification (Third Revision) Complete Rs 2700/- View breakup
-
- -
Complete
337 IS 12600 (1989) Portland cement, low heat - specification - - View breakup
-
- -
Facility not available for heat of hydration test & Transverse strength
338 IS 280 (2006) Mild steel wire for general engineering purposes (Fourth Revision) For all sizes except tests mentioned in remarks Rs.3750.00 View breakup
-
- -
Chem- Facility not available for Al (when Al- killed), Also see status for IS 7887
339 IS 12367 (1988) Specification for cold - Rolled carbon steel strips/coils for manufacture of welded tubes All grades/varieties - View breakup
-
- -
Grade to be declared. Chem- Facility not available for Al, V, Nb, Ti, B & Mo. Type of killing and grade to be declared
340 IS 1239 : Part 2 (2011) Steel tubes, tubulars and other steel fittings - Specification: Part 2 steel pipe fittings (Fifth Revision) All types/sizes (pl see remarks) 3400 View breakup
-
- -
Mech- Facility not available for Cl 11.1 (Hydrostatic or pneumatic), Taper screw plug test (Cl 11.2.2). Method of manufacture, type and size designation to be declared.
341 IS 5950 (1984) Specification for shot firing cables (For Use Other Than In Shafts) (First Revision) all sizes/varieties Rs 11030/- View breakup
-
- -
Complete
342 IS 14255 (1995) Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification complete for Cat 01(Except melt flow, vicat, bending) Please see remarks View breakup
Rs.16650.00 for XLPE insulated single core cable Rs.15150.00 for PE insulated single core cable
- -
Facility not available for breaking load of messenger conductor, Carbon Black test, Vicat Test, Environmental stress cracking for PE insulation. For XLPE water absorption test facility available upto 25 sq.mm. (Facility for nominal area of conductor, Tensile & Elongation above 2.0 mm thickness is not available). 5 mtr Aluminium wire before stranding to be provided additionally.
343 IS 15997 (2012) Low nickel austenitic stainless steel sheet and strip for utensils and kitchen appliances - Specification All types (please see remarks) Rs 2850 View breakup
-
- -
Mech-Type of conditioning, heat treatment, grade, form size,finish to be declared.. Chem- Facility not available for S, Mo(>1.5), C (<0.05)
344 IS 16208 (2015) Textiles - High density polyethylene (HDPE)/polypropylene (PP) woven sacks for packaging 10 kg, 15 kg, 20 kg, 25 kg and 30 kg foodgrains - Specification all varieties. Rs.19750/- (including all parameters), Rs.10450/- (excl View breakup
-
- -
Complete.
345 IS 1061 (2017) Disinfectant fluids, phenolic type - Specification (Fifth Revision) Class, Grade and Type to be declared Class Black fluid-Rs.9204. Class White fluid - Rs.10504 View breakup
Testing charges for Disinfectant Fluids, Phenolic Type as per IS 1061 : 2017, Class - Black fluid - Rs. 9204 Testing charges for Disinfectant Fluids, Phenolic Type as per IS 1061 : 2017, Class - White fluid - Rs. 10504
- -
To declare Grade, Type and class.
346 IS 10631 (1983) Specification for stainless steel for welding electrode core wire All designations (please see remarks) - View breakup
-
- -
Mech- complete; Chem- except C(<0.05%), S, Nb, Mo (>1.5%). Size and designation to be declared.
347 IS 16353 (2015) Portland Cement Clinker - Specification - Rs. 5700/ View breakup
-
- -
Chem-Declaration for chloride regarding end use of cement (as per Table 1), Confirmation required for testing Alkali Content. Mechanical- Gypsum to be provided separately for grinding with clinker. As per Cl 6.1 testing can not be carried out if gypsum is not provided.
348 IS 7098 : Part 1 (1988) Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) complete cat 01(except water absorption above 25sqmm) 26250 View breakup
-
- -
Elec-For cat.-01: Up to 240 sq mm all tests can be carried out (except water absorption). However, facility not available for Loss of mass above 1.2 mm thickness, Tensile & Elongation above 2.0 mm thickness and Water absorption test above 25 sq.mm cable. All facilities available for C1 & C2- except additional tests
349 IS 3074 (2013) Steel tubes for automotive purposes - Specification (Third Revision) All grades except for the tests mentioned in remarks 4200 View breakup
-
- -
Facility not available for leak tightness test. Grade designation, type, class, condition to be declared. Chem- Complete for CDS but Partial for ERW,CEW (facility not available for micro alloying elements)
350 IS 398 : Part 5 (1992) Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) All sizes/varieties 11400 View breakup
Excluding Breaking load on complete conductor, Surface condition test, Corona test and Radio interference test
- -
Elec-Facility not available for surface condition,corona test ,radio interference test, Breaking Load on complete conductor.
351 IS 398 : Part 4 (1994) Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) Complete facility available upto 100 sq mm only Rs 825/- upto 7 wires, Rs 1425/- upto 19 wires View breakup
-
- -
Elec-Complete facility available upto 100 sq mm only. For Above 100 sq.mm. facility not available for Stress-Strain Test, Surface Condition, Ultimate B/L on stranded conductor.
352 IS 1417 (2016) Gold and gold alloys, jewellery/ artefacts - Fineness and marking - Specification (Fourth Revision) 22K 916 , 18K 750 , 14 K 585 Rs.1800.00 View breakup
-
- -
For gold jewellery having fineness of 585, 750 and 916 only
353 IS 13428 (2005) Packaged natural mineral water specification (Second Revision) - 19200 View breakup
All except Radio Active Residues (RAR)- Rs 19200.00, All except Pesticide Residues (PRs) & RARs- Rs. 13900.00, All except Micro, PRs & RARs- Rs. 8750.00, Only Micro- Rs. 5900.00
- -
Excluding Cyanide, Radio Active Elements
354 IS 3812 (Part 1) (2013) Pulverized fuel ash - Specification: Part 1 For use as pozzolana in cement, cement mortar and concrete - Rs. 21850/- View breakup
-
- -
Type of Fuel ash to be declared, Declaration required regarding Moisture requirement
355 IS 2062 (2011) Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) For all grades except for the tests mentioned in remarks 3200 View breakup
-
- -
Mech - Facility not available for NDT tests ; for impact test prepared pieces to be sent; Prepared test piece to be sent for Y groove crackability test. Chem- Facility not available for Microalloys & Al. Type of Killed material, Carbon Equivalent & Nitrogen content to be indicated in case the same are to be tested.
356 IS 12818 (2010) Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) All sizes/types Rs.6450.00 View breakup
-
- -
Chemical: All except Effect on Water which is for Pipes above 60 mm Nominal dia and except for the requirement of 'Other Toxic Substances such a di-n-octyl Tin -s-s bis iso-octyl mercapto acetate' and 'butyl stearate'; Mech- All except HST.
357 IS 4985 (2000) Unplasticized pvc pipes for potable water supplies - Specification (Third Revision) All sizes/varieties 4550 View breakup
-
- -
Chemical: All except Effect on Water which is for Pipes above 60 mm Nominal dia and except for the requirement of 'Other Toxic Substances such a di-n-octyl Tin -s-s bis iso-octyl mercapto acetate' and 'butyl stearate'; Mech- All except HST.
358 IS 398 : Part 2 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) Complete up to 100 sqmm Please see remarks. View breakup
-
- -
All tests are available up to and including 100 sq.mm. For Above 100 sq.mm. facility not available for Stress-Strain Test, Surface Condition, Ultimate B/L on stranded conductor.
359 IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) For all grades except for the tests mentioned in remarks 25780 View breakup
-
- -
Mech - Facility not available for pull out test, total elongation at maximum force. Chem- Facility not available for Micro-alloying elements. Declarations regarding type of 'Killed' material, Micro-alloys/low-alloys, Nitrogen content or any other parameter as per Note under clause 4.2 to be provided.
360 IS 1554 : Part 1 (1988) Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) Complete for Cat 01(up to 400sq.mm)Except optional test Rs 26700 View breakup
-
- -
For Category-01 and upto 400 sq mm: all tests are available except additional tests. For cat. C1 and C2 : Except oxygen Index,Temperature index, Flame Retardance, Smoke Density,

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.

Contact for any query/support: supportlims@bis.gov.in