BIS, Eastern Regional Laboratory (ERL)

(1) Annex Building & Sample-Cell: Bureau of Indian Standards, P-230, CIT Scheme, VII- M, Block-W,Kankurgachi,Kolkata-700054 (2) Main building: 1/14, CIT Scheme VII M, VIP Road, Kankurgachi,Kolkata-700054, Kolkata, Kolkata, West Bengal, 700054
- erol@bis.gov.in
Scope List
Reset
330 Results
S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
301 IS 3975 (1999) Low carbon galvanized steel wires, formed wires and tapes for armouring of cables - Specification (Third Revision) Complete Rs 2700/- View breakup
-
- -
-
302 IS 12600 (1989) Portland cement, low heat - specification - - View breakup
-
- -
Facility not available for heat of hydration test & TransverseĀ strength
303 IS 280 (2006) Mild steel wire for general engineering purposes (Fourth Revision) For all sizes except tests mentioned in remarks Rs.3750.00 View breakup
-
- -
Chem- Facility not available for Al (when Al- killed), Also see status for IS 7887
304 IS 12367 (1988) Specification for cold - Rolled carbon steel strips/coils for manufacture of welded tubes All grades/varieties - View breakup
-
- -
Grade to be declared. Chem- Facility not available for Al, V, Nb, Ti, B & Mo. Type of killing and grade to be declared
305 IS 1239 : Part 2 (2011) Steel tubes, tubulars and other steel fittings - Specification: Part 2 steel pipe fittings (Fifth Revision) All types/sizes (pl see remarks) - View breakup
Rs. 5410/- (excl. test on joints and expansion test in sockets) and testing charges as per relevant referred Iss
- -
Mech- Facility not available for Cl 11.1 (Hydrostatic or pneumatic), Taper screw plug test (Cl 11.2.2). Method of manufacture, type and size designation to be declared.
306 IS 5950 (1984) Specification for shot firing cables (For Use Other Than In Shafts) (First Revision) all sizes/varieties Rs 11030/- View breakup
-
- -
-
307 IS 14255 (1995) Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification complete for Cat 01(Except melt flow, vicat, bending) - View breakup
Rs.16650.00 for XLPE insulated single core cable Rs.15150.00 for PE insulated single core cable
- -
Facility not available for breaking load of messenger conductor, Carbon Black test, Vicat Test, Environmental stress cracking for PE insulation. For XLPE water absorption test facility available upto 25 sq.mm. (Facility for nominal area of conductor, Tensile & Elongation above 2.0 mm thickness is not available). 5 mtr Aluminium wire before stranding to be provided additionally.
308 IS 15997 (2012) Low nickel austenitic stainless steel sheet and strip for utensils and kitchen appliances - Specification All types (please see remarks) Rs 2850 View breakup
-
- -
Mech-Type of conditioning, heat treatment, grade, form size,finish to be declared.. Chem- Facility not available for S, Mo(>1.5), C (<0.05)
309 IS 16208 (2015) Textiles - High density polyethylene (HDPE)/polypropylene (PP) woven sacks for packaging 10 kg, 15 kg, 20 kg, 25 kg and 30 kg foodgrains - Specification all varieties. Rs.19750/- (including all parameters), Rs.10450/- (excl View breakup
-
- -
Mech- Excluding UV resistance. Type and material to be declared.
310 IS 1061 (2017) Disinfectant fluids, phenolic type - Specification (Fifth Revision) Class, Grade and Type to be declared - View breakup
-
- -
To declare Grade, Type and class.
311 IS 10631 (1983) Specification for stainless steel for welding electrode core wire All designations (please see remarks) - View breakup
-
- -
Chem- Facility not available for C(<0.05%), S, Nb, Mo (>1.5%). Size and designation to be declared.
312 IS 16353 (2015) Portland Cement Clinker - Specification - Rs. 5700/ View breakup
-
- -
Chem-Declaration for chloride regarding end use of cement (as per Table 1), Confirmation required for testing Alkali Content.
313 IS 7098 : Part 1 (1988) Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) complete cat 01(except water absorption above 25sqmm) - View breakup
-
- -
Elec-For cat.-01: Up to 240 sq mm all tests can be carried out (except water absorption). However, facility not available for Loss of mass above 1.2 mm thickness, Tensile & Elongation above 2.0 mm thickness and Water absorption test above 25 sq.mm cable. All facilities available for C1 & C2- except additional tests
314 IS 3074 (2013) Steel tubes for automotive purposes - Specification (Third Revision) All grades except for the tests mentioned in remarks - View breakup
-
- -
Facility not available for leak tightness test. Grade designation, type, class, condition to be declared. Chem- Complete for CDS but Partial for ERW,CEW (facility not available for micro alloying elements)
315 IS 398 : Part 5 (1992) Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) All sizes/varieties 11400 View breakup
Excluding Breaking load on complete conductor, Surface condition test, Corona test and Radio interference test
- -
Elec-Facility not available for surface condition,corona test ,radio interference test, Breaking Load on complete conductor.
316 IS 398 : Part 4 (1994) Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) Complete facility available upto 100 sq mm only Rs 825/- upto 7 wires, Rs 1425/- upto 19 wires View breakup
-
- -
Elec-Complete facility available upto 100 sq mm only. For Above 100 sq.mm. facility not available for Stress-Strain Test, Surface Condition, Ultimate B/L on stranded conductor.
317 IS 1417 (2016) Gold and gold alloys, jewellery/ artefacts - Fineness and marking - Specification (Fourth Revision) 22K 916 , 18K 750 , 14 K 585 Rs.1800.00 View breakup
-
- -
-
318 IS 13428 (2005) Packaged natural mineral water specification (Second Revision) - - View breakup
All except Radio Active Residues (RAR)- Rs 19200.00, All except Pesticide Residues (PRs) & RARs- Rs. 13900.00, All except Micro, PRs & RARs- Rs. 8750.00, Only Micro- Rs. 5900.00
- -
Excluding Cyanide, Radio Active Elements
319 IS 3812 (Part 1) (2013) Pulverized fuel ash - Specification: Part 1 For use as pozzolana in cement, cement mortar and concrete - Rs. 21850/- View breakup
-
- -
Type of Fuel ash to be declared, Declaration required regarding Moisture requirement
320 IS 2062 (2011) Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) For all grades except for the tests mentioned in remarks - View breakup
-
- -
Mech - Facility not available for NDT tests ; for impact test prepared pieces to be sent; Prepared test piece to be sent for Y groove crackability test. Chem- Facility not available for Microalloys & Al. Type of Killed material, Carbon Equivalent & Nitrogen content to be indicated in case the same are to be tested.
321 IS 12818 (2010) Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) All sizes/types - View breakup
-
- -
Chemical: All except Effect on Water which is for Pipes above 60 mm Nominal dia and except for the requirement of 'Other Toxic Substances such a di-n-octyl Tin -s-s bis iso-octyl mercapto acetate' and 'butyl stearate'; Mech- All except HST.
322 IS 4985 (2000) Unplasticized pvc pipes for potable water supplies - Specification (Third Revision) All sizes/varieties - View breakup
-
- -
Chemical: All except Effect on Water which is for Pipes above 60 mm Nominal dia and except for the requirement of 'Other Toxic Substances such a di-n-octyl Tin -s-s bis iso-octyl mercapto acetate' and 'butyl stearate'; Mech- All except HST.
323 IS 2347 (2017) Domestic pressure cooker - Specification (Sixth Revision) - - View breakup
-
- -
Facility not available for Cl 8.6(test for Outer lid type),8.7,8.8,8.9,8.10,7.4, For Chemical tests, see status of IS for individual components (IS 21/6911/5522).
324 IS 398 : Part 2 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) Complete up to 100 sqmm - View breakup
-
- -
All tests are available up to and including 100 sq.mm. For Above 100 sq.mm. facility not available for Stress-Strain Test, Surface Condition, Ultimate B/L on stranded conductor.
325 IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) For all grades except for the tests mentioned in remarks - View breakup
-
- -
Mech - Facility not available for pull out test, total elongation at maximum force. Chem- Facility not available for Micro-alloying elements. Declarations regarding type of 'Killed' material, Micro-alloys/low-alloys, Nitrogen content or any other parameter as per Note under clause 4.2 to be provided.
326 IS 1554 : Part 1 (1988) Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) Complete for Cat 01(up to 400sq.mm)Except optional test - View breakup
Rs.16650/- for single core unarmoured cable, Rs.22500/- for two core, unarmoured cable, Rs.26700/- for two core armoured cable (Excluding addl. Type test for cables with improved fire performance.) For multi core cables, extra charges @ 35 % for each additional core shall be levied. Material testing charges as per relevant referred ISs Testing charges for Additional Type Tests for Improved Fire Performance Tests: Rs. 7100/- for category C1 Rs. 11700/- for category C2
- -
For Category-01 and upto 400 sq mm: all tests are available except additional tests. For cat. C1 and C2 : Except oxygen Index,Temperature index, Flame Retardance, Smoke Density, Halogen acid Gas Evolution
327 IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
Mech-Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement required as per Table 1, Confirmation for testing Alkali Content required.
328 IS 4984 (2016) Polyethylene pipes for water supply - Specification (Fifth Revision) All varieties - View breakup
-
- -
Mech- Facility not available for- Hydraulic test, Slow Crack Growth Rate and Internal Pressure Creep Rupture test. Fused pipes required to be provided for T/S of butt fusion joints. Chem- Facility available
329 IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
-
- -
Mech- Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement (as per Table 1) and declaration of fly ash content & Confirmation for testing Alkali Content required.
330 IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) Complete for Category 01- up to & including 400 sq mm - View breakup
-
- -
Chem- Facility available for Cu purity only,Gr to be declared. Elect- Cat -01, 02 (Facility not available for- Loss of mass above 1.2 mm, Tensile & Elongation above 2.0 mm thickness.) Cat- FR, FR-LSH-( Facility not available for- oxygen index, temp. index test, Smoke Density Tests). Chem- Facility available for Cu purity only,Grade/class to be declared

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.

Contact for any query/support: supportlims@bis.gov.in