BIS, Eastern Regional Laboratory (ERL)

(1) Annex Building & Sample-Cell: Bureau of Indian Standards, P-230, CIT Scheme, VII- M, Block-W,Kankurgachi,Kolkata-700054 (2) Main building: 1/14, CIT Scheme VII M, VIP Road, Kankurgachi,Kolkata-700054, Kolkata, Kolkata, West Bengal, 700054
- erol@bis.gov.in
Scope List
Reset
287 Results
S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Exclusion Testing Charges (Excl. Of Taxes) Facility Type Effective Date Validity Date Remark
271 IS 3074 (2013) Steel tubes for automotive purposes - Specification (Third Revision) All grades except for the tests mentioned in remarks - - View breakup
-
Partial - Facility not available for leak tightness test. Grade designation, type, class, condition to be declared. Chem- Complete for CDS but Partial for ERW,CEW (facility not available for micro alloying elements)
272 IS 398 : Part 5 (1992) Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) All sizes/varieties - - View breakup
-
Partial - Elec-Facility not available for surface condition,corona test ,radio interference test, Breaking Load on complete conductor.
273 IS 398 : Part 4 (1994) Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) Complete facility available upto 100 sq mm only - - View breakup
-
Partial - Elec-Complete facility available upto 100 sq mm only. For Above 100 sq.mm. facility not available for Stress-Strain Test, Surface Condition, Ultimate B/L on stranded conductor.
274 IS 1417 (2016) Gold and gold alloys, jewellery/ artefacts - Fineness and marking - Specification (Fourth Revision) 22K 916 , 18K 750 , 14 K 585 - - View breakup
-
Complete - -
275 IS 13428 (2005) Packaged natural mineral water specification (Second Revision) - - - View breakup
-
Partial - Excluding Cyanide, Radio Active Elements
276 IS 3812 (Part 1) (2013) Pulverized fuel ash - Specification: Part 1 For use as pozzolana in cement, cement mortar and concrete - - - View breakup
-
Partial - Mech-Facility not available for Lime Reactivity. Chem - Facility not available for Reactive Silica, Type of Fuel ash to be declared, Declaration required regarding Moisture requirement
277 IS 2062 (2011) Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) For all grades except for the tests mentioned in remarks - - View breakup
-
Partial - Mech - Facility not available for NDT tests ; for impact test prepared pieces to be sent; Prepared test piece to be sent for Y groove crackability test. Chem- Facility not available for Microalloys & Al. Type of Killed material, Carbon Equivalent & Nitrogen content to be indicated in case the same are to be tested.
278 IS 12818 (2010) Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) All sizes/types - - View breakup
-
Partial - Facility not available for Internal dia (Cl 9.2), critical dimensions (for screen pipes). Chem- Facility not availabe for Effect on Water (Cl 9.7)
279 IS 4985 (2000) Unplasticized pvc pipes for potable water supplies - Specification (Third Revision) All sizes/varieties - - View breakup
-
Partial - Mech- Facility not available hydrostatic test, Chem- Except Effect on water
280 IS 2347 (2017) Domestic pressure cooker - Specification (Sixth Revision) - - - View breakup
-
Partial - Facility not available for Cl 8.6(test for Outer lid type),8.7,8.8,8.9,8.10,7.4, For Chemical tests, see status of IS for individual components (IS 21/6911/5522).
281 IS 398 : Part 2 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) Complete up to 100 sqmm - - View breakup
-
Partial - All tests are available up to and including 100 sq.mm. For Above 100 sq.mm. facility not available for Stress-Strain Test, Surface Condition, Ultimate B/L on stranded conductor.
282 IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) For all grades except for the tests mentioned in remarks - - View breakup
-
Partial - Mech - Facility not available for pull out test, total elongation at maximum force. Chem- Facility not available for Micro-alloying elements. Declaration regarding type of 'Killed' material, Micro-alloys/low-alloys, Nitrogen content or any other parameter as per Note under clause 4.2 to be provided.
283 IS 1554 : Part 1 (1988) Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) Complete for Cat 01(up to 400sq.mm)Except optional test - - View breakup
-
Partial - For Category-01 and upto 400 sq mm: all tests are available except additional tests. For cat. C1 and C2 : Except oxygen Index,Temperature index, Flame Retardance, Smoke Density, Halogen acid Gas Evolution
284 IS 455 (2015) Portland slag cement - Specification - - - View breakup
-
Partial - Mech-Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement required as per Table 1, Confirmation for testing Alkali Content required.
285 IS 4984 (2016) Polyethylene pipes for water supply - Specification (Fifth Revision) All varieties - - View breakup
-
Partial - Mech- Facility not available for- Hydraulic test, Slow Crack Growth Rate and Internal Pressure Creep Rupture test. Chem- Facility not available for Oxidation Induction time
286 IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - - View breakup
-
Partial - Mech- Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement (as per Table 1) and declaration of fly ash content & Confirmation for testing Alkali Content required.
287 IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) Complete for Category 01- up to & including 400 sq mm - - View breakup
-
Partial - Chem- Facility available for Cu purity only,Gr to be declared. Elect- Cat -01, 02 (Facility not available for- Loss of mass above 1.2 mm, Tensile & Elongation above 2.0 mm thickness.) Cat- FR, FR-LSH-( Facility not available for- oxygen index, temp. index test, halogen Acid Gas Evolution, Smoke Density Tests). Chem- Facility available for Cu purity only,Grade/class to be declared

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.

Contact for any query/support: supportlims@bis.gov.in