BIS, Eastern Regional Laboratory (ERL)

(1) Annex Building & Sample-Cell: Bureau of Indian Standards, P-230, CIT Scheme, VII- M, Block-W,Kankurgachi,Kolkata-700054 (2) Main building: 1/14, CIT Scheme VII M, VIP Road, Kankurgachi,Kolkata-700054, Kolkata, Kolkata, West Bengal, 700054
- erol@bis.gov.in
Scope List
Reset
287 Results
S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Exclusion Testing Charges (Excl. Of Taxes) Facility Type Effective Date Validity Date Remark
241 IS 2830 (2012) Carbon steel cast billet ingots, billets, blooms and slabs for re-rolling into steel for general structural purposes - Specification (Third Revision) For all designations except tests mentioned in remarks - - View breakup
-
Partial - Chem- Facility not available for Al, CE & Micro Alloying elements. To indicate the type of 'Killed' material, if applicable. Also to indicate any other information as per Note under Table-1.
242 IS 8737 (2017) Valve fittings for use with liquefied petroleum gas (LPG) cylinders for more than 5 litre water capacity - Specification (Second Revision) - - - View breakup
-
Partial - Facility not available for hydrostatic test, thread measurement, pneumatic, cycle test, Chem- 'Others' as elements not specified in ISS. Size/variety to be declared.
243 IS 281 (2009) Mild steel sliding door bolts for use with padlocks - Specification (Fourth Revision) - - - View breakup
-
Partial - Chem- Facility not available for Cl 5, Nb, V, Al, Ti, B. Type to be declared
244 IS 5484 (1997) Ec grade aluminium rod produced by continuous casting and rolling - Specification (Second Revision) complete - - View breakup
-
Partial - Test facility is not available for Aluminium, Titanium, vanadium & Zirconium. Tensile strength range to be declared.
245 IS 8952 (1995) Steel ingots, blooms and billets for production of mild steel wire rods for general engineering purposes - Specification (First Revision) All grades except for the tests mentioned in remarks - - View breakup
-
Partial - Chem- Facility not available for Nb, V, Ti & Al. Grades to be declared
246 IS 963 (1958) Specification for chrome molybdenum steel bars and rods for aircraft purposes All grades except for the tests mentioned in remarks - - View breakup
-
Partial - Chem- Facility not available for Mo.
247 IS 2681 (1993) Non - Ferrous metal sliding door bolts (Aldrops) for use with padlocks - Specification (Third Revision) All grades (pl see remarks) - - View breakup
-
Partial - Chem-Facility not available for micro alloying elements, for cast iron- facility not available for Sulphur
248 IS 204 : Part 1 (1991) Tower bolts - Specification: Part 1 ferrous metals (Fifth Revision) All grades (except tests mentioned in remarks) - - View breakup
-
Partial - Chem-Facility not available for micro alloying elements, for cast iron- facility not available for Sulphur
249 IS 9962 (1981) Specification for steel wire for needles all size and grade - - View breakup
-
Partial - Grade,size and finish to be declared
250 IS 277 (2018) Galvanized steel strips and sheets (Plain And Corrugated) - Specification (Seventh Revision) For all grades except tests mentioned in remarks - - View breakup
-
Partial - Chem- Facility not available for microalloying elements & Al. To specify Grade/Designation for base metal.
251 IS 1812 (1982) Specification for carbon steel wire for the manufacture of wood screws (Second Revision) - - - View breakup
-
Complete - Chem- Type of killed material to be declared,
252 IS 15911 (2010) Structural steel (Ordinary Quality) - Specification All grades - - View breakup
-
Partial - Chem- C, S, P, Mn, Si, Cu & N can only be carried out.Grade designation to be declared.
253 IS 1489 : Part 2 (2015) Portland - Pozzolana cement - Specification: Part 2 calcined clay based - - - View breakup
-
Partial - Mech-Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement (as per Table 1) and declaration of fly ash content & Confirmation for testing Alkali Content required.
254 IS 278 (2009) Galvanized steel barbed wire for fencing - Specification (Fourth Revision) For all varietiesexcept tests mentioned in remarks - - View breakup
-
Partial - Mech- Complete. 3 mtr point wire to be provided additionally.. Chem- Facility not available for Al (when Al- killed). Also see status for IS 7887
255 IS 191 (2007) Copper - Specification (Fourth Revision) All - - View breakup
-
Partial - Chem-Only Cu purity test can be carried out, Complete Test Facilities for Electrical Test
256 IS 1566 (1982) Specification for hard - Drawn steel wire fabric for concrete reinforcement (Second Revision) all grades - - View breakup
-
Partial - Chem- Except Microalloys & Al tests.
257 IS 12776 (2002) Galvanized strand for earthing - Specification (First Revision) All sizes/grades (pl see remarks) - - View breakup
-
Partial - Except Breaking Load of Complete wire. "Declarations Required: Size & Tensile Grade".5 mtr sample (before stranding) to be provided additionally.
258 IS 3975 (1999) Low carbon galvanized steel wires, formed wires and tapes for armouring of cables - Specification (Third Revision) Complete - - View breakup
-
Complete - -
259 IS 12600 (1989) Portland cement, low heat - specification - - - View breakup
-
Partial - Facility not available for heat of hydration test & Transverse strength
260 IS 280 (2006) Mild steel wire for general engineering purposes (Fourth Revision) For all sizes except tests mentioned in remarks - - View breakup
-
Partial - Chem- Facility not available for Al (when Al- killed), Also see status for IS 7887
261 IS 12367 (1988) Specification for cold - Rolled carbon steel strips/coils for manufacture of welded tubes All grades/varieties - - View breakup
-
Partial - Grade to be declared. Chem- Facility not available for Al, V, Nb, Ti, B & Mo. Type of killing and grade to be declared
262 IS 1239 : Part 2 (2011) Steel tubes, tubulars and other steel fittings - Specification: Part 2 steel pipe fittings (Fifth Revision) All types/sizes (pl see remarks) - - View breakup
-
Partial - Mech- Facility not available for Cl 11.1 (Hydrostatic or pneumatic), Taper screw plug test (Cl 11.2.2). Method of manufacture, type and size designation to be declared.
263 IS 5950 (1984) Specification for shot firing cables (For Use Other Than In Shafts) (First Revision) all sizes/varieties - - View breakup
-
Partial - -
264 IS 14255 (1995) Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification complete for Cat 01(Except melt flow, vicat, bending) - - View breakup
-
Partial - Facility not available for breaking load of messenger conductor, Carbon Black test, Vicat Test, Environmental stress cracking for PE insulation. For XLPE water absorption test facility available upto 25 sq.mm. (Facility for nominal area of conductor, Tensile & Elongation above 2.0 mm thickness is not available). 5 mtr Aluminium wire before stranding to be provided additionally.
265 IS 15997 (2012) Low nickel austenitic stainless steel sheet and strip for utensils and kitchen appliances - Specification All types (please see remarks) - - View breakup
-
Partial - Mech-Type of conditioning, heat treatment, grade, form size,finish to be declared.. Chem- Facility not available for S, Mo(>1.5), C (<0.05)
266 IS 16208 (2015) Textiles - High density polyethylene (HDPE)/polypropylene (PP) woven sacks for packaging 10 kg, 15 kg, 20 kg, 25 kg and 30 kg foodgrains - Specification all varieties. - - View breakup
-
Partial - Mech- Excluding UV resistance. Type and material to be declared.
267 IS 1061 (2017) Disinfectant fluids, phenolic type - Specification (Fifth Revision) Class, Grade and Type to be declared - - View breakup
-
Partial - To declare Grade, Type and class.
268 IS 10631 (1983) Specification for stainless steel for welding electrode core wire All designations (please see remarks) - - View breakup
-
Partial - Chem- Facility not available for C(<0.05%), S, Nb, Mo (>1.5%). Size and designation to be declared.
269 IS 16353 (2015) Portland Cement Clinker - Specification - - - View breakup
-
Partial - Chem-Declaration for chloride regarding end use of cement (as per Table 1), Confirmation required for testing Alkali Content.
270 IS 7098 : Part 1 (1988) Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) complete cat 01(except water absorption above 25sqmm) - - View breakup
-
Partial - Elec-For cat.-01: Up to 240 sq mm all tests can be carried out (except water absorption). However, facility not available for Loss of mass above 1.2 mm thickness, Tensile & Elongation above 2.0 mm thickness and Water absorption test above 25 sq.mm cable. All facilities available for C1 & C2- except additional tests

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.

Contact for any query/support: supportlims@bis.gov.in