| 1 |
IS/IEC 62368 : Part 1 (2023) |
Audio Video Information and Communication Technology Equipment - Part 1: Safety Requirements (Second Revision) |
-- |
175000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1(General- materials, components) |
- |
1000 |
|
- |
| Cl-4.2(Energy source classifications) |
- |
500 |
|
- |
| Cl-4.3(Protection against energy sources) |
- |
1000 |
|
- |
| Cl-4.4(Safeguards) |
- |
1000 |
|
- |
| Cl-4.5(Explosion) |
- |
2000 |
|
- |
| Cl-4.6(Fixing of conductors and conductive parts) |
- |
1000 |
|
- |
| Cl-4.7(Equipment for direct insertion into mains socket-outlets) |
- |
1000 |
|
- |
| Cl-4.8(Equipment containing coin or button cell batteries) |
- |
1000 |
|
- |
| Cl-4.9(Likelihood of fire or shock due to entry of conductive objects) |
- |
1000 |
|
- |
| Cl-4.10(Components requirements) |
- |
3000 |
|
- |
| Cl-5.1(General- Electrically-caused injury) |
- |
2000 |
|
- |
| Cl-5.2(Classification and limits of electrical energy sources) |
- |
3000 |
|
- |
| Cl-5.3(Protection against electrical energy sources) |
- |
1000 |
|
- |
| Cl-5.4(Insulation materials and requirements) |
- |
3000 |
|
- |
| Cl-5.5(Components as safeguards) |
- |
2000 |
|
- |
| Cl-5.6(Protective conductor) |
- |
3000 |
|
- |
| Cl-5.7(Prospective touch voltage, touch current and protective conductor current) |
- |
3000 |
|
- |
| Cl-5.8(Backfeed safeguard in battery backed up supplies) |
- |
2000 |
|
- |
| Cl-6.1(General- Electrically-caused fire) |
- |
2000 |
|
- |
| Cl-6.2(Classification of power sources and potential ignition sources) |
- |
2000 |
|
- |
| Cl-6.3(Safeguards against fire under normal operating conditions and abnormal operating conditions) |
- |
2000 |
|
- |
| Cl-6.4(Safeguards against fire under single fault conditions) |
- |
2000 |
|
- |
| Cl-6.5(Internal and external wiring) |
- |
1000 |
|
- |
| Cl-7.1(General- Injury caused by hazardous substances) |
- |
500 |
|
- |
| Cl-7.2(Reduction of exposure to hazardous substances) |
- |
1000 |
|
- |
| Cl-7.3(Ozone exposure) |
- |
500 |
|
- |
| Cl-7.4(Use of personal safeguards or personal protective equipment (PPE) |
- |
500 |
|
- |
| Cl-7.5(Use of instructional safeguards and instructions) |
- |
500 |
|
- |
| Cl-8.1(General- Mechanically-caused injury) |
- |
1000 |
|
- |
| Cl-8.2(Mechanical energy source classifications) |
- |
1000 |
|
- |
| Cl-8.3(Safeguards against mechanical energy sources) |
- |
1000 |
|
- |
| Cl-8.4(Safeguards against parts with sharp edges and corners) |
- |
1000 |
|
- |
| Cl-8.5(Safeguards against moving parts) |
- |
1000 |
|
- |
| Cl-8.6(Stability of equipment) |
- |
2000 |
|
- |
| Cl-8.7(Equipment mounted to a wall, ceiling or other structure) |
- |
2000 |
|
- |
| Cl-8.8(Handle strength) |
- |
1000 |
|
- |
| Cl-8.9(Wheels or casters attachment requirements) |
- |
1000 |
|
- |
| Cl-8.10(Carts, stands, and similar carriers) |
- |
1000 |
|
- |
| Cl-8.11(Mounting means for slide-rail mounted equipment (SRME)) |
- |
1000 |
|
- |
| Cl-9.1(General-Thermal burn injury) |
- |
1000 |
|
- |
| Cl-9.2(Thermal energy source classifications) |
- |
1000 |
|
- |
| Cl-9.3(Touch temperature limits) |
- |
2000 |
|
- |
| Cl-9.4(Safeguards against thermal energy sources) |
- |
1000 |
|
- |
| Cl-9.5(Requirements for safeguards) |
- |
1000 |
|
- |
| Cl-9.6(Requirements for wireless power transmitters) |
- |
2000 |
|
- |
| Cl-10.1(General-Radiation) |
- |
500 |
|
- |
| Cl-10.2(Radiation energy source classifications) |
- |
500 |
|
- |
| Cl-10.3(Safeguards against laser radiation) |
- |
1000 |
|
- |
| Cl-10.4("Safeguards against optical radiation from lamps and lamp systems
(including LED types)") |
- |
1000 |
|
- |
| Cl-10.5(Safeguards against X-radiation) |
- |
500 |
|
- |
| Cl-10.6(Safeguards against acoustic energy sources) |
- |
500 |
|
- |
| Annex A(Examples of equipment within the scope of this document) |
- |
500 |
|
- |
| Annex B(General- Normal operating condition tests, abnormal operating condition tests and single fault condition tests) |
- |
2000 |
|
- |
| Annex B-2(Normal operating conditions) |
- |
1000 |
|
- |
| Annex B-3(Simulated abnormal operating conditions) |
- |
1000 |
|
- |
| Annex B-4(Simulated single fault conditions) |
- |
2000 |
|
- |
| Annex C-1(Protection of materials in equipment from UV radiation) |
- |
0 |
|
- |
| Annex C-2(UV light conditioning test) |
- |
0 |
|
- |
| Annex D-1(Impulse test generators) |
- |
3000 |
|
- |
| Annex D-2(Antenna interface test generator) |
- |
3000 |
|
- |
| Annex D-3(Electronic pulse generator) |
- |
0 |
|
- |
| Annex E-1(Electrical energy source classification for audio signals) |
- |
2000 |
|
- |
| Annex E-2(Audio signals used during test) |
- |
2000 |
|
- |
| Annex E-3(Operating conditions of equipment containing an audio amplifier) |
- |
2000 |
|
- |
| Annex F-1(General-Equipment markings, instructions, and instructional safeguards) |
- |
1000 |
|
- |
| Annex F-2(Letter symbols and graphical symbols) |
- |
1000 |
|
- |
| Annex F-3(Equipment markings) |
- |
2000 |
|
- |
| Annex F-4(Instructions) |
- |
1000 |
|
- |
| Annex F-5(Instructional safeguards) |
- |
1000 |
|
- |
| Annex G-1(Switches) |
- |
1000 |
|
- |
| Annex G-2(Relays) |
- |
1000 |
|
- |
| Annex G-3(Protective devices) |
- |
1000 |
|
- |
| Annex G-4(Connectors) |
- |
1000 |
|
- |
| Annex G-5(Wound components) |
- |
2000 |
|
- |
| Annex G-6(Wire insulation) |
- |
1000 |
|
- |
| Annex G-7(Mains power supply cords and interconnection cables) |
- |
2000 |
|
- |
| Annex G-8(Varistors) |
- |
500 |
|
- |
| Annex G-9(Integrated circuit (IC) current limiters) |
- |
1000 |
|
- |
| Annex G-10(Resistors) |
- |
500 |
|
- |
| Annex G-11(Capacitors and RC units) |
- |
1000 |
|
- |
| Annex G-12(Optocouplers) |
- |
500 |
|
- |
| Annex G-13(Printed boards) |
- |
2000 |
|
- |
| Annex G-14(Coatings on component terminals) |
- |
1000 |
|
- |
| Annex G-15(Pressurized liquid filled components or LFC assemblies) |
- |
1000 |
|
- |
| Annex G-16(IC that includes a capacitor discharge function (ICX)) |
- |
1000 |
|
- |
| Annex H-1(General- Criteria for telephone ringing signals) |
- |
1000 |
|
- |
| Annex H-2(Method A) |
- |
1000 |
|
- |
| Annex H-3(Method B) |
- |
1000 |
|
- |
| Annex I(Overvoltage categories (see IEC 60364-4-44)) |
- |
500 |
|
- |
| Annex J-1(General-Insulated winding wires for use without interleaved insulation) |
- |
1000 |
|
- |
| Annex J-2(Type tests) |
- |
2000 |
|
- |
| Annex J-3(Testing during manufacturing) |
- |
2000 |
|
- |
| Annex K-1(General- Safety interlocks) |
- |
500 |
|
- |
| Annex K-2(Components of the safety interlock safeguard mechanism) |
- |
500 |
|
- |
| Annex K-3(Inadvertent change of operating mode) |
- |
500 |
|
- |
| Annex K-4(Interlock safeguard override) |
- |
500 |
|
- |
| Annex K-5(Fail-safe) |
- |
500 |
|
- |
| Annex K-6(Mechanically operated safety interlocks) |
- |
0 |
|
- |
| Annex K-7(Interlock circuit isolation) |
- |
0 |
|
- |
| Annex L-1(General requirements) |
- |
500 |
|
- |
| Annex L-2(Permanently connected equipment) |
- |
1000 |
|
- |
| Annex L-3() |
- |
1000 |
|
- |
| Annex L-4(Single-phase equipment) |
- |
1000 |
|
- |
| Annex L-5(Three-phase equipment) |
- |
1000 |
|
- |
| Annex L-6(Switches as disconnect devices) |
- |
1000 |
|
- |
| Annex L-7(Plugs as disconnect devices) |
- |
1000 |
|
- |
| Annex L-8(Multiple power sources) |
- |
1000 |
|
- |
| Annex L-9(Compliance criteria) |
- |
1000 |
|
- |
| Annex M-1(General requirements) |
- |
500 |
|
- |
| Annex M-2(Safety of batteries and their cells) |
- |
500 |
|
- |
| Annex M-3(Protection circuits for batteries provided within the equipment) |
- |
500 |
|
- |
| Annex M-4(Additional safeguards for equipment containing a secondary lithium battery) |
- |
500 |
|
- |
| Annex M-5(Risk of burn due to short-circuit during carrying) |
- |
1000 |
|
- |
| Annex M-6(Safeguards against short-circuits) |
- |
500 |
|
- |
| Annex M-7(Risk of explosion from lead acid and NiCd batteries) |
- |
0 |
|
- |
| Annex M-8("Protection against internal ignition from external spark sources of
rechargeable batteries with aqueous electrolyte") |
- |
0 |
|
- |
| Annex M-9(Preventing electrolyte spillage) |
- |
500 |
|
- |
| Annex M-10(Instructions to prevent reasonably foreseeable misuse) |
- |
500 |
|
- |
| Annex N(Electrochemical potentials (V)) |
- |
500 |
|
- |
| Annex O(Measurement of creepage distances and clearances) |
- |
1000 |
|
- |
| Annex P-1(General-Safeguards against conductive objects) |
- |
500 |
|
- |
| Annex P-2(Safeguards against entry or consequences of entry of a foreign object) |
- |
1000 |
|
- |
| Annex P-3(Safeguards against spillage of internal liquids) |
- |
1000 |
|
- |
| Annex P-4(Metallized coatings and adhesives securing parts) |
- |
500 |
|
- |
| Annex Q-1(Limited power source) |
- |
2000 |
|
- |
| Annex R(Limited short-circuit test) |
- |
2000 |
|
- |
| Annex S-1(Flammability test for fire enclosure and fire barrier materials of equipment where the steady state power does not exceed 4 000 W) |
- |
2000 |
|
- |
| Annex S-2(Flammability test for fire enclosure and fire barrier integrity) |
- |
2000 |
|
- |
| Annex S-3(Flammability tests for the bottom of a fire enclosure) |
- |
1999.99 |
|
- |
| Annex S-4(Flammability classification of materials) |
- |
1000 |
|
- |
| Annex S-5(Flammability test for fire enclosure materials of equipment with a steady state power exceeding 4 000 W) |
- |
1000 |
|
- |
| Annex S-6(Grille covering material, cloth, and reticulated foam) |
- |
500 |
|
- |
| Annex T-1(General-Mechanical strength tests) |
- |
500 |
|
- |
| Annex T-2(Steady force test, 10 N) |
- |
500 |
|
- |
| Annex T-3(Steady force test, 30 N) |
- |
1000 |
|
- |
| Annex T-4(Steady force test, 100 N) |
- |
1000 |
|
- |
| Annex T-5(Steady force test, 250 N) |
- |
1000 |
|
- |
| Annex T-6(Enclosure impact test) |
- |
1000 |
|
- |
| Annex T-7(Drop test) |
- |
1000 |
|
- |
| Annex T-8(Stress relief test) |
- |
2000 |
|
- |
| Annex T-9(Glass impact test) |
- |
1000 |
|
- |
| Annex T-10(Glass fragmentation test) |
- |
1000 |
|
- |
| Annex T-11(Test for telescoping or rod antennas) |
- |
1000 |
|
- |
| Annex U("Mechanical strength of CRTs and protection against the effects
of implosion") |
- |
0 |
|
- |
| Annex V-1(Accessible parts of equipment) |
- |
1000 |
|
- |
| Annex V-2(Accessible part criterion) |
- |
1000 |
|
- |
| Annex W(Comparison of terms introduced in this document) |
- |
1000 |
|
- |
| Annex X("Alternative method for determining clearances for insulation in
circuits connected to an AC mains not exceeding 420 V peak (300 V RMS)") |
- |
1000 |
|
- |
| Annex Y-1(General- Construction requirements for outdoor enclosures) |
- |
1000 |
|
- |
| Annex Y-2(Resistance to UV radiation) |
- |
0 |
|
- |
| Annex Y-3(Resistance to corrosion) |
- |
2000 |
|
- |
| Annex Y-4(Gaskets) |
- |
2000 |
|
- |
| Annex Y-5(Protection of equipment within an outdoor enclosure) |
- |
2000 |
|
- |
| Annex Y-6(Mechanical strength of enclosures) |
- |
1000 |
|
- |
| Annex Q-2(Test for external circuits – paired conductor cable) |
- |
1000 |
|
- |
| Cl-4.1(General- materials, components) |
- |
0 |
|
- |
| Cl-4.2(Energy source classifications) |
- |
0 |
|
- |
| Cl-4.3(Protection against energy sources) |
- |
0 |
|
- |
| Cl-4.4(Safeguards) |
- |
0 |
|
- |
| Cl-4.5(Explosion) |
- |
0 |
|
- |
| Cl-4.6(Fixing of conductors and conductive parts) |
- |
0 |
|
- |
| Cl-4.7(Equipment for direct insertion into mains socket-outlets) |
- |
0 |
|
- |
| Cl-4.8(Equipment containing coin or button cell batteries) |
- |
0 |
|
- |
| Cl-4.9(Likelihood of fire or shock due to entry of conductive objects) |
- |
0 |
|
- |
| Cl-4.10(Components requirements) |
- |
0 |
|
- |
| Cl-5.1(General- Electrically-caused injury) |
- |
0 |
|
- |
| Cl-5.2(Classification and limits of electrical energy sources) |
- |
0 |
|
- |
| Cl-5.3(Protection against electrical energy sources) |
- |
0 |
|
- |
| Cl-5.4(Insulation materials and requirements) |
- |
0 |
|
- |
| Cl-5.5(Components as safeguards) |
- |
0 |
|
- |
| Cl-5.6(Protective conductor) |
- |
0 |
|
- |
| Cl-5.7(Prospective touch voltage, touch current and protective conductor current) |
- |
0 |
|
- |
| Cl-5.8(Backfeed safeguard in battery backed up supplies) |
- |
0 |
|
- |
| Cl-6.1(General- Electrically-caused fire) |
- |
0 |
|
- |
| Cl-6.2(Classification of power sources and potential ignition sources) |
- |
0 |
|
- |
| Cl-6.3(Safeguards against fire under normal operating conditions and abnormal operating conditions) |
- |
0 |
|
- |
| Cl-6.4(Safeguards against fire under single fault conditions) |
- |
0 |
|
- |
| Cl-6.5(Internal and external wiring) |
- |
0 |
|
- |
| Cl-7.1(General- Injury caused by hazardous substances) |
- |
0 |
|
- |
| Cl-7.2(Reduction of exposure to hazardous substances) |
- |
0 |
|
- |
| Cl-7.3(Ozone exposure) |
- |
0 |
|
- |
| Cl-7.4(Use of personal safeguards or personal protective equipment (PPE) |
- |
0 |
|
- |
| Cl-7.5(Use of instructional safeguards and instructions) |
- |
0 |
|
- |
| Cl-8.1(General- Mechanically-caused injury) |
- |
0 |
|
- |
| Cl-8.2(Mechanical energy source classifications) |
- |
0 |
|
- |
| Cl-8.3(Safeguards against mechanical energy sources) |
- |
0 |
|
- |
| Cl-8.4(Safeguards against parts with sharp edges and corners) |
- |
0 |
|
- |
| Cl-8.5(Safeguards against moving parts) |
- |
0 |
|
- |
| Cl-8.6(Stability of equipment) |
- |
0 |
|
- |
| Cl-8.7(Equipment mounted to a wall, ceiling or other structure) |
- |
0 |
|
- |
| Cl-8.8(Handle strength) |
- |
0 |
|
- |
| Cl-8.9(Wheels or casters attachment requirements) |
- |
0 |
|
- |
| Cl-8.10(Carts, stands, and similar carriers) |
- |
0 |
|
- |
| Cl-8.11(Mounting means for slide-rail mounted equipment (SRME)) |
- |
0 |
|
- |
| Cl-9.1(General-Thermal burn injury) |
- |
0 |
|
- |
| Cl-9.2(Thermal energy source classifications) |
- |
0 |
|
- |
| Cl-9.3(Touch temperature limits) |
- |
0 |
|
- |
| Cl-9.4(Safeguards against thermal energy sources) |
- |
0 |
|
- |
| Cl-9.5(Requirements for safeguards) |
- |
0 |
|
- |
| Cl-9.6(Requirements for wireless power transmitters) |
- |
0 |
|
- |
| Cl-10.1(General-Radiation) |
- |
0 |
|
- |
| Cl-10.2(Radiation energy source classifications) |
- |
0 |
|
- |
| Cl-10.3(Safeguards against laser radiation) |
- |
0 |
|
- |
| Cl-10.4("Safeguards against optical radiation from lamps and lamp systems
(including LED types)") |
- |
0 |
|
- |
| Cl-10.5(Safeguards against X-radiation) |
- |
0 |
|
- |
| Cl-10.6(Safeguards against acoustic energy sources) |
- |
0 |
|
- |
| Annex A(Examples of equipment within the scope of this document) |
- |
0 |
|
- |
| Annex B(General- Normal operating condition tests, abnormal operating condition tests and single fault condition tests) |
- |
0 |
|
- |
| Annex B-2(Normal operating conditions) |
- |
0 |
|
- |
| Annex B-3(Simulated abnormal operating conditions) |
- |
0 |
|
- |
| Annex B-4(Simulated single fault conditions) |
- |
0 |
|
- |
| Annex D-1(Impulse test generators) |
- |
0 |
|
- |
| Annex D-2(Antenna interface test generator) |
- |
0 |
|
- |
| Annex E-1(Electrical energy source classification for audio signals) |
- |
0 |
|
- |
| Annex E-2(Audio signals used during test) |
- |
0 |
|
- |
| Annex E-3(Operating conditions of equipment containing an audio amplifier) |
- |
0 |
|
- |
| Annex F-1(General-Equipment markings, instructions, and instructional safeguards) |
- |
0 |
|
- |
| Annex F-2(Letter symbols and graphical symbols) |
- |
0 |
|
- |
| Annex F-3(Equipment markings) |
- |
0 |
|
- |
| Annex F-4(Instructions) |
- |
0 |
|
- |
| Annex F-5(Instructional safeguards) |
- |
0 |
|
- |
| Annex G-1(Switches) |
- |
0 |
|
- |
| Annex G-2(Relays) |
- |
0 |
|
- |
| Annex G-3(Protective devices) |
- |
0 |
|
- |
| Annex G-4(Connectors) |
- |
0 |
|
- |
| Annex G-5(Wound components) |
- |
0 |
|
- |
| Annex G-6(Wire insulation) |
- |
0 |
|
- |
| Annex G-7(Mains power supply cords and interconnection cables) |
- |
0 |
|
- |
| Annex G-8(Varistors) |
- |
0 |
|
- |
| Annex G-9(Integrated circuit (IC) current limiters) |
- |
0 |
|
- |
| Annex G-10(Resistors) |
- |
0 |
|
- |
| Annex G-11(Capacitors and RC units) |
- |
0 |
|
- |
| Annex G-12(Optocouplers) |
- |
0 |
|
- |
| Annex G-13(Printed boards) |
- |
0 |
|
- |
| Annex G-14(Coatings on component terminals) |
- |
0 |
|
- |
| Annex G-15(Pressurized liquid filled components or LFC assemblies) |
- |
0 |
|
- |
| Annex G-16(IC that includes a capacitor discharge function (ICX)) |
- |
0 |
|
- |
| Annex H-1(General- Criteria for telephone ringing signals) |
- |
0 |
|
- |
| Annex H-2(Method A) |
- |
0 |
|
- |
| Annex H-3(Method B) |
- |
0 |
|
- |
| Annex I(Overvoltage categories (see IEC 60364-4-44)) |
- |
0 |
|
- |
| Annex J-1(General-Insulated winding wires for use without interleaved insulation) |
- |
0 |
|
- |
| Annex J-2(Type tests) |
- |
0 |
|
- |
| Annex J-3(Testing during manufacturing) |
- |
0 |
|
- |
| Annex K-1(General- Safety interlocks) |
- |
0 |
|
- |
| Annex K-2(Components of the safety interlock safeguard mechanism) |
- |
0 |
|
- |
| Annex K-3(Inadvertent change of operating mode) |
- |
0 |
|
- |
| Annex K-4(Interlock safeguard override) |
- |
0 |
|
- |
| Annex K-5(Fail-safe) |
- |
0 |
|
- |
| Annex K-6(Mechanically operated safety interlocks) |
- |
0 |
|
- |
| Annex K-7(Interlock circuit isolation) |
- |
0 |
|
- |
| Annex L-1(General requirements) |
- |
0 |
|
- |
| Annex L-2(Permanently connected equipment) |
- |
0 |
|
- |
| Annex L-3() |
- |
0 |
|
- |
| Annex L-4(Single-phase equipment) |
- |
0 |
|
- |
| Annex L-5(Three-phase equipment) |
- |
0 |
|
- |
| Annex L-6(Switches as disconnect devices) |
- |
0 |
|
- |
| Annex L-7(Plugs as disconnect devices) |
- |
0 |
|
- |
| Annex L-8(Multiple power sources) |
- |
0 |
|
- |
| Annex L-9(Compliance criteria) |
- |
0 |
|
- |
| Annex M-1(General requirements) |
- |
0 |
|
- |
| Annex M-2(Safety of batteries and their cells) |
- |
0 |
|
- |
| Annex M-3(Protection circuits for batteries provided within the equipment) |
- |
0 |
|
- |
| Annex M-4(Additional safeguards for equipment containing a secondary lithium battery) |
- |
0 |
|
- |
| Annex M-5(Risk of burn due to short-circuit during carrying) |
- |
0 |
|
- |
| Annex M-6(Safeguards against short-circuits) |
- |
0 |
|
- |
| Annex M-9(Preventing electrolyte spillage) |
- |
0 |
|
- |
| Annex M-10(Instructions to prevent reasonably foreseeable misuse) |
- |
0 |
|
- |
| Annex N(Electrochemical potentials (V)) |
- |
0 |
|
- |
| Annex O(Measurement of creepage distances and clearances) |
- |
0 |
|
- |
| Annex P-1(General-Safeguards against conductive objects) |
- |
0 |
|
- |
| Annex P-2(Safeguards against entry or consequences of entry of a foreign object) |
- |
0 |
|
- |
| Annex P-3(Safeguards against spillage of internal liquids) |
- |
0 |
|
- |
| Annex P-4(Metallized coatings and adhesives securing parts) |
- |
0 |
|
- |
| Annex Q-1(Limited power source) |
- |
0 |
|
- |
| Annex R(Limited short-circuit test) |
- |
0 |
|
- |
| Annex S-1(Flammability test for fire enclosure and fire barrier materials of equipment where the steady state power does not exceed 4 000 W) |
- |
0 |
|
- |
| Annex S-2(Flammability test for fire enclosure and fire barrier integrity) |
- |
0 |
|
- |
| Annex S-3(Flammability tests for the bottom of a fire enclosure) |
- |
0 |
|
- |
| Annex S-4(Flammability classification of materials) |
- |
0 |
|
- |
| Annex S-5(Flammability test for fire enclosure materials of equipment with a steady state power exceeding 4 000 W) |
- |
0 |
|
- |
| Annex S-6(Grille covering material, cloth, and reticulated foam) |
- |
0 |
|
- |
| Annex T-1(General-Mechanical strength tests) |
- |
0 |
|
- |
| Annex T-2(Steady force test, 10 N) |
- |
0 |
|
- |
| Annex T-3(Steady force test, 30 N) |
- |
0 |
|
- |
| Annex T-4(Steady force test, 100 N) |
- |
0 |
|
- |
| Annex T-5(Steady force test, 250 N) |
- |
0 |
|
- |
| Annex T-6(Enclosure impact test) |
- |
0 |
|
- |
| Annex T-7(Drop test) |
- |
0 |
|
- |
| Annex T-8(Stress relief test) |
- |
0 |
|
- |
| Annex T-9(Glass impact test) |
- |
0 |
|
- |
| Annex T-10(Glass fragmentation test) |
- |
0 |
|
- |
| Annex T-11(Test for telescoping or rod antennas) |
- |
0 |
|
- |
| Annex V-1(Accessible parts of equipment) |
- |
0 |
|
- |
| Annex V-2(Accessible part criterion) |
- |
0 |
|
- |
| Annex W(Comparison of terms introduced in this document) |
- |
0 |
|
- |
| Annex X("Alternative method for determining clearances for insulation in
circuits connected to an AC mains not exceeding 420 V peak (300 V RMS)") |
- |
0 |
|
- |
| Annex Y-1(General- Construction requirements for outdoor enclosures) |
- |
0 |
|
- |
| Annex Y-3(Resistance to corrosion) |
- |
0 |
|
- |
| Annex Y-4(Gaskets) |
- |
0 |
|
- |
| Annex Y-5(Protection of equipment within an outdoor enclosure) |
- |
0 |
|
- |
| Annex Y-6(Mechanical strength of enclosures) |
- |
0 |
|
- |
| Annex Q-2(Test for external circuits – paired conductor cable) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f 04.06.2026 |
| 2 |
IS 2167 (2025) |
Commercial Beverage Coolers - Specification (ISO 22044 : 2021, MOD) (Fourth Revision) |
- |
400000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.5.1(Classification According To Temperature) |
- |
1000 |
|
- |
| Cl.5.2(Construction) |
- |
2000 |
|
- |
| Cl.6.2.2(Seal Test For Door And Lids) |
- |
5000 |
|
- |
| Cl.6.2.3(Test On Durability Of Door And Lid) |
- |
50000 |
|
- |
| Cl.6.2.4(Linear Dimensions, Areas And Volumes) |
- |
5000 |
|
- |
| Cl.6.3.11.2(Temperature Test) |
- |
20000 |
|
- |
| Cl.6.3.11.3(Half Load Recovery Test) |
- |
50000 |
|
- |
| Cl.6.3.11.3.6(Energy Consumption test) |
- |
50000 |
|
- |
| Cl.6.3.12(Water Vapour Condensation Test) |
- |
50000 |
|
- |
| Cl.6.3.13(Specific Energy Consumption (SEC)) |
- |
50000 |
|
- |
| Cl.6.3.14 and Annex G(Lighting Test) |
- |
5000 |
|
- |
| Cl.7(Marking) |
- |
5000 |
|
- |
| Annex B(Net Volume Calculation) |
- |
5000 |
|
- |
| Annex C(Equivalent Volume Calculation) |
- |
5000 |
|
- |
| Annex D(Tda Calculation) |
- |
5000 |
|
- |
| Annex E(Tests For Absence Of Odour And Taste) |
- |
30000 |
|
- |
| 5.1(Classification according to temperature) |
- |
0 |
|
- |
| 5.2(Construction) |
- |
0 |
|
- |
| 5.2,5.2.1(General) |
- |
0 |
|
- |
| 5.2,5.2.2(Materials) |
- |
0 |
|
Charges covered in Cl 5.2 |
| 5.2,5.2.3(Thermal insulation) |
- |
0 |
|
Charges covered in Cl 5.2 |
| 5.2,5.2.4(Refrigerating system) |
- |
0 |
|
Charges covered in Cl 5.2 |
| 5.2,5.2.5(Electrical components) |
- |
0 |
|
Charges covered in Cl 5.22 |
| 6.1(General) |
- |
2000 |
|
- |
| 6.2.1,Aneex E(Absence of odour and taste (not compulsory)) |
- |
0 |
|
- |
| 6.2.2(Seal test for doors and lids) |
- |
0 |
|
- |
| 6.2.3(Test on durability of door and lid) |
- |
0 |
|
- |
| 6.2.4(Linear dimensions, areas and volumes) |
- |
0 |
|
- |
| 6.3.2(Test room condition) |
- |
5000 |
|
- |
| 6.3.3(M-can) |
- |
5000 |
|
- |
| 6.3.4(Preparation of test commercial beverage cooler and general test procedures) |
- |
5000 |
|
- |
| 6.3.5(Loading the commercial beverage cooler) |
- |
10000 |
|
- |
| 6.3.6(Running in period) |
- |
10000 |
|
- |
| 6.3.7(Stable conditions) |
- |
10000 |
|
- |
| 6.3.8(Lighting and night-covers) |
- |
10000 |
|
- |
| 6.3.9(Power supply) |
- |
5000 |
|
- |
| 6.3.10(Testing several commercial beverage coolers in the same room) |
- |
0 |
|
- |
| 6.3.11.2(Temperature test) |
- |
0 |
|
- |
| 6.3.11.3(Half reload recovery test) |
- |
0 |
|
- |
| 6.3.11.3.6(Energy consumption test) |
- |
0 |
|
- |
| 6.3.12(Water vapour condensation test) |
- |
0 |
|
- |
| 6.3.13(Calculation of specific energy consumption (SEC)) |
- |
0 |
|
- |
| 6.3.14(Lighting test) |
- |
0 |
|
- |
| 7.2(Marking plate) |
- |
0 |
|
- |
| Annex B(Net volume calculation) |
- |
0 |
|
- |
| Annex C(Equivalent volume calculation) |
- |
0 |
|
- |
| Annex D(Total display area (TDA)) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f 04.06.2026 |
| 3 |
IS 18689 (2024) |
Household and Similar Electrical Appliances - Safety - Particular Requirements for Commercial Refrigerating Appliances and Ice-Makers with an Incorporated or Remote Refrigerant Unit or Motor-Compressor (IEC 60335-2-89 : 2019, MOD) |
- |
250000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
5000 |
|
- |
| 8(Protection against access to live parts) |
- |
5000 |
|
- |
| 10(Power input and current) |
- |
15000 |
|
- |
| 10.101(Power input and current) |
- |
0 |
|
Testing Charges covered in Cl.10 |
| 11(Heating) |
- |
20000 |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
5000 |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
5000 |
|
- |
| 14(Transient overvoltages) |
- |
10000 |
|
- |
| 15(Moisture resistance) |
- |
15000 |
|
- |
| 15.101,15.102,15.103(Moisture resistance) |
- |
0 |
|
Testing Charges covered in Cl.15 |
| 16.1 &16.2(Leakage current test) |
- |
5000 |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
5000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
10000 |
|
- |
| 19(Abnormal operation) |
- |
30000 |
|
Testing Charges Rs. 30000 /- is for Cl. 19 (Excluding EMI/EMC Tests of Cl.19.11.4.1 to Cl.19.11.4.7).
If applicable, the testing charges Rs. 89000/- for EMI/EMC tests will be charged extra for the respective EMI/EMC tests. |
| 19.101(Abnormal operation) |
- |
0 |
|
Testing charges covered in Cl.19 |
| 19.102(Abnormal operation) |
- |
0 |
|
Testing charges covered in Cl.19 |
| 19.103(Abnormal operation) |
- |
0 |
|
Testing charges covered in Cl.19 |
| 20(Stability and mechanical hazards) |
- |
10000 |
|
- |
| 21(Mechanical strength) |
- |
10000 |
|
- |
| 21.101(Mechanical strength) |
- |
0 |
|
Testing charges covered in Cl.21 |
| 21.102(Mechanical strength) |
- |
0 |
|
Testing charges covered in Cl.21 |
| 21.103(Mechanical strength) |
- |
0 |
|
Testing charges covered in Cl.21 |
| 22(Construction) |
- |
40000 |
|
- |
| 23(Internal wiring) |
- |
5000 |
|
- |
| 24(Components) |
- |
5000 |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
5000 |
|
- |
| 26("Terminals for external
conductors") |
- |
5000 |
|
- |
| 27(Provision for earthing) |
- |
5000 |
|
- |
| 28(Screws and connections) |
- |
5000 |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
10000 |
|
- |
| 30("Resistance to heat and fire
") |
- |
15000 |
|
- |
| 31(Resistance to rusting) |
- |
5000 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8(Protection against access to live parts) |
- |
0 |
|
- |
| 10(Power input and current) |
- |
0 |
|
- |
| 10.101(Power input and current) |
- |
0 |
|
- |
| 11(Heating) |
- |
0 |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
0 |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
0 |
|
- |
| 14(Transient overvoltages) |
- |
0 |
|
- |
| 15(Moisture resistance) |
- |
0 |
|
- |
| 15.101,15.102,15.103(Moisture resistance) |
- |
0 |
|
- |
| 16.1 &16.2(Leakage current test) |
- |
0 |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 19(Abnormal operation) |
- |
0 |
|
- |
| 19.101(Abnormal operation) |
- |
0 |
|
- |
| 19.102(Abnormal operation) |
- |
0 |
|
- |
| 19.103(Abnormal operation) |
- |
0 |
|
- |
| 20(Stability and mechanical hazards) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 21.101(Mechanical strength) |
- |
0 |
|
- |
| 21.102(Mechanical strength) |
- |
0 |
|
- |
| 21.103(Mechanical strength) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
0 |
|
- |
| 26("Terminals for external
conductors") |
- |
0 |
|
- |
| 27(Provision for earthing) |
- |
0 |
|
- |
| 28(Screws and connections) |
- |
0 |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
0 |
|
- |
| 30("Resistance to heat and fire
") |
- |
0 |
|
- |
| 31(Resistance to rusting) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8(Protection against access to live parts) |
- |
0 |
|
- |
| 10(Power input and current) |
- |
0 |
|
- |
| 10.101(Power input and current) |
- |
0 |
|
- |
| 11(Heating) |
- |
0 |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
0 |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
0 |
|
- |
| 14(Transient overvoltages) |
- |
0 |
|
- |
| 15(Moisture resistance) |
- |
0 |
|
- |
| 15.101,15.102,15.103(Moisture resistance) |
- |
0 |
|
- |
| 16.1 &16.2(Leakage current test) |
- |
0 |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 19(Abnormal operation) |
- |
0 |
|
- |
| 19.101(Abnormal operation) |
- |
0 |
|
- |
| 19.102(Abnormal operation) |
- |
0 |
|
- |
| 19.103(Abnormal operation) |
- |
0 |
|
- |
| 20(Stability and mechanical hazards) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 21.101(Mechanical strength) |
- |
0 |
|
- |
| 21.102(Mechanical strength) |
- |
0 |
|
- |
| 21.103(Mechanical strength) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
0 |
|
- |
| 26("Terminals for external
conductors") |
- |
0 |
|
- |
| 27(Provision for earthing) |
- |
0 |
|
- |
| 28(Screws and connections) |
- |
0 |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
0 |
|
- |
| 30("Resistance to heat and fire
") |
- |
0 |
|
- |
| 31(Resistance to rusting) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8(Protection against access to live parts) |
- |
0 |
|
- |
| 10(Power input and current) |
- |
0 |
|
- |
| 10.101(Power input and current) |
- |
0 |
|
- |
| 11(Heating) |
- |
0 |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
0 |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
0 |
|
- |
| 14(Transient overvoltages) |
- |
0 |
|
- |
| 15(Moisture resistance) |
- |
0 |
|
- |
| 15.101,15.102,15.103(Moisture resistance) |
- |
0 |
|
- |
| 16.1 &16.2(Leakage current test) |
- |
0 |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 19(Abnormal operation) |
- |
0 |
|
- |
| 19.101(Abnormal operation) |
- |
0 |
|
- |
| 19.102(Abnormal operation) |
- |
0 |
|
- |
| 19.103(Abnormal operation) |
- |
0 |
|
- |
| 20(Stability and mechanical hazards) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 21.101(Mechanical strength) |
- |
0 |
|
- |
| 21.102(Mechanical strength) |
- |
0 |
|
- |
| 21.103(Mechanical strength) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
0 |
|
- |
| 26("Terminals for external
conductors") |
- |
0 |
|
- |
| 27(Provision for earthing) |
- |
0 |
|
- |
| 28(Screws and connections) |
- |
0 |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
0 |
|
- |
| 30("Resistance to heat and fire
") |
- |
0 |
|
- |
| 31(Resistance to rusting) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f. 08.04.2026
Exclusion: 22.32 (Construction) |
| 4 |
IS 302 : Part 2 : Sec 40 (2025) |
Safety of Household and Similar Electrical Appliances Part 2 Particular Requirements Sec 40 Electrical Heat Pumps, Air-Conditioners and Dehumidifiers (IEC 60335-2-40 : 2022, MOD) |
- |
300000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32(Radiation, toxicity and similar hazards) |
- |
5000 |
|
- |
| 31(Resistance to rusting) |
- |
5000 |
|
- |
| 30(Resistance to heat and fire) |
- |
10000 |
|
- |
| 29(Clearances, creepage distances and solid insulation) |
- |
10000 |
|
- |
| 28(Screws and connections) |
- |
5000 |
|
- |
| 27(Provision for earthing) |
- |
5000 |
|
- |
| 26(Terminals for external conductors) |
- |
5000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
5000 |
|
- |
| 24(Components) |
- |
5000 |
|
- |
| 23(Internal wiring) |
- |
5000 |
|
- |
| 22.117(Hot surfaces) |
- |
0 |
|
Testing Charges covered in Cl.22 |
| 22.116(Arcs and sparks from electric components) |
- |
0 |
|
Testing Charges covered in Cl.22 |
| 22(Construction) |
- |
35000 |
|
- |
| 21(Mechanical strength) |
- |
10000 |
|
- |
| 19.104.8(Back up protection test) |
- |
30000 |
|
Testing Charges for Cl. 19 (Excluding EMI/EMC Tests of Cl.19.11.4.1 to Cl.19.11.4.7) is Rs. 30000/- The testing charges for EMI/EMC tests will be charged extra as applicable as mentioned in the respective clauses.. |
| 20(Stability and mechanical hazards) |
- |
10000 |
|
- |
| 19.11.4.7(Mains signals) |
- |
5000 |
|
- |
| 19.11.4.6(Class 3 voltage dips and interruptions) |
- |
5000 |
|
- |
| 19.11.4.5(Injected currents) |
- |
10000 |
|
- |
| 19.11.4.4(Voltage dips and interruptions) |
- |
5000 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
5000 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
20000 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
5000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
10000 |
|
- |
| 16(Leakage current and electric strength) |
- |
10000 |
|
- |
| 15.101(Spillage test) |
- |
0 |
|
Testing Charges covered in Cl.15 |
| 15(Moisture resistance) |
- |
15000 |
|
- |
| 14(Transient overvoltages) |
- |
10000 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
10000 |
|
- |
| 12(Void) |
- |
0 |
|
- |
| 11(Heating) |
- |
20000 |
|
- |
| 10(Power input and current) |
- |
15000 |
|
- |
| 8(Protection against access to live parts) |
- |
5000 |
|
- |
| 7(Marking and instructions) |
- |
5000 |
|
- |
| 6(Classification) |
- |
0 |
|
- |
| 5(General conditions for the tests) |
- |
0 |
|
- |
| 4(General requirement) |
- |
0 |
|
- |
| 32(Radiation, toxicity and similar hazards) |
- |
0 |
|
- |
| 31(Resistance to rusting) |
- |
0 |
|
- |
| 30(Resistance to heat and fire) |
- |
0 |
|
- |
| 29(Clearances, creepage distances and solid insulation) |
- |
0 |
|
- |
| 28(Screws and connections) |
- |
0 |
|
- |
| 27(Provision for earthing) |
- |
0 |
|
- |
| 26(Terminals for external conductors) |
- |
0 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 22.117(Hot surfaces) |
- |
0 |
|
- |
| 22.116(Arcs and sparks from electric components) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 19.104.8(Back up protection test) |
- |
0 |
|
- |
| 20(Stability and mechanical hazards) |
- |
0 |
|
- |
| 19.11.4.7(Mains signals) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.5(Injected currents) |
- |
0 |
|
- |
| 19.11.4.4(Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 16(Leakage current and electric strength) |
- |
0 |
|
- |
| 15.101(Spillage test) |
- |
0 |
|
- |
| 15(Moisture resistance) |
- |
0 |
|
- |
| 14(Transient overvoltages) |
- |
0 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
| 12(Void) |
- |
0 |
|
- |
| 11(Heating) |
- |
0 |
|
- |
| 10(Power input and current) |
- |
0 |
|
- |
| 8(Protection against access to live parts) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 6(Classification) |
- |
0 |
|
- |
| 5(General conditions for the tests) |
- |
0 |
|
- |
| 4(General requirement) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f. 01.04.2026
Exclusion: 32 (Radiation, toxicity and similar hazards), 22 (Construction), 24 (Components) |
| 5 |
IS 18112 (2025) |
DIGITAL TELEVISION RECEIVER FOR SATELLITE BROADCAST TRANSMISSION SPECIFICATION (First Revision) |
- |
428000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.4, Table-2, ii)(RF characteristics to be supported by the DTV receiver) |
- |
0 |
|
- |
| Clause 4.3(Specifications) |
- |
50000 |
|
Separately covered as per IS 616 |
| Clause 4.5(Safety Requirements) |
- |
0 |
|
- |
| Clause 4.6(Electromagnetic Compatibility (EMC) Requirements) |
- |
140000 |
|
- |
| Clause 5(Marking) |
- |
2000 |
|
- |
| Clause 6(Operating Life Test) |
- |
10000 |
|
- |
| Clause 4.1, Table-1, i) a)(Hardware specification) |
- |
3000 |
|
- |
| Clause 4.1, Table-1, i) b)(Decompression and decoding of SDTV video) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, i) c)(Decompression and decoding of HDTV video) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, i) d)(Decompression and decoding of audio) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, i) e)(Active Format descriptors) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, i) f)(Captioning and Sub-titling) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, i) g)(Teletext) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, i) h)(Multi-language support) |
- |
3000 |
|
- |
| Clause 4.1, Table-1, i) j)(DTV receiver mixed Audio Description) |
- |
3000 |
|
- |
| Clause 4.1, Table-1, i) k)(Broadcast mixed audio description) |
- |
3000 |
|
- |
| Clause 4.1, Table-1, i) m)(Service demultiplexing) |
- |
3000 |
|
- |
| Clause 4.1, Table-1, i) n)(Data services) |
- |
3000 |
|
- |
| Clause 4.1, Table-1, i) p)(OSD) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, i) q)(DTV character set) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, i) r)(Electronic Service Guide (ESG) ‘Now/Next’) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, i) s)(Time) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, i) t)(Digital TV output) |
- |
5000 |
|
- |
| Clause 4.4, Table-2, i) b)(Frequency) |
- |
5000 |
|
- |
| Clause 4.4, Table-2, i) a)(Input voltage range) |
- |
5000 |
|
- |
| Clause 4.1,Table-1, ii) a)(Demodulation and FEC decoding) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, ii) b)(DTV Receiver Installation) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, ii) c)(Network evolution) |
- |
5000 |
|
- |
| Clause 4.4, Table-2, iii) c)(RF input impedance) |
- |
0 |
|
- |
| Clause 4.1, Table-1, ii) d)(Services available) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, ii) e)(Selection via Service List) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, ii) f)(Selection via Numeric Entry) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, ii) g)(Favourite Channel list) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, ii) h)(Hidden Services) |
- |
5000 |
|
- |
| Clause 4.4, Table-2, iii) b)(Input frequency range) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, ii) j)(Logical Channel Number for Satellite services) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, ii) k)(RF input signal) |
- |
10000 |
|
- |
| Clause 4.1, Table-1, ii) m)(LNB supply current) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, ii) n)(LNB supply voltage) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, ii) p)(LNB Control) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, ii) q)(Modulation/Demodulation parameters for DVB-S & DVB-S2 standard) |
- |
0 |
|
- |
| Clause 4.4, Table-2, iii) a)(Input level per carrier) |
- |
15000 |
|
- |
| Clause 4.4, Table-2, iv) c)(RF input impedance) |
- |
0 |
|
- |
| Clause 4.4, Table-2, iv) b)(Input frequency range) |
- |
5000 |
|
- |
| Clause 4.4, Table-2, iv) a)(Input level per carrier) |
- |
15000 |
|
- |
| Clause 4.4, Table-2, v)(Symbol rate) |
- |
5000 |
|
- |
| Clause 4.4, Table-2, vi)(RF input return loss) |
- |
0 |
|
- |
| Clause 4.4, Table-2, vii)(DisEqC) |
- |
5000 |
|
- |
| Clause 4.4, Table-2, viii)(Operating ambient temperature range) |
- |
0 |
|
- |
| Clause 4.4, Table-2, ix)(Operating humidity range) |
- |
0 |
|
- |
| Clause 4.1, Table-1, iii) a)(Interfaces, Connectors) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, iv)(Automatic software upgrade mechanism) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, v) a)(Remote Control) |
- |
5000 |
|
- |
| Clause 4.1, Table-1, v) b)(Easy to use and simple documentation) |
- |
5000 |
|
- |
| Clause 3.1, Table-1, v) c)(Support package) |
- |
3000 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f. 13.11.2025 |
| 6 |
IS 17550 : Part 3 (2025) |
Household Refrigerating Appliances - Characteristics and Methods Of Test Part 3 Energy Consumption and Volume (First Revision) |
- |
160000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.1, Annex A(set up for energy consumption) |
- |
0 |
|
- |
| Clause 4.2, Annex B(Steady state power consumption) |
- |
0 |
|
- |
| Clause 4.3, Annex C(Defrost and Recovery Energy and Temperature Change) |
- |
0 |
|
- |
| Clause 4.4, Annex D(Defrost Frequency) |
- |
0 |
|
- |
| Clause 4.5, Annex E(Number of Test Points and Interpolation) |
- |
0 |
|
- |
| Clause 4.6, Annex G(Load Processing Efficiency) |
- |
0 |
|
- |
| Clause 4.7, Annex F(Specified Auxiliaries) |
- |
0 |
|
- |
| Clause 4.8, Annex H(Volume determination) |
- |
10000 |
|
- |
| Clause 4.8.1, Annex H(Rated total volume) |
- |
0 |
|
- |
| Clause 5, 5.1, 5.2 Table 1(TARGET TEMPERATURES FOR ENERGY DETERMINATION) |
- |
0 |
|
- |
| Clause 6, 6.1 to 6.8(DETERMINATION OF ENERGY CONSUMPTION) |
- |
150000 |
|
- |
| Clause 4.1, Annex A(set up for energy consumption) |
- |
0 |
|
- |
| Clause 4.2, Annex B(Steady state power consumption) |
- |
0 |
|
- |
| Clause 4.3, Annex C(Defrost and Recovery Energy and Temperature Change) |
- |
0 |
|
- |
| Clause 4.4, Annex D(Defrost Frequency) |
- |
0 |
|
- |
| Clause 4.5, Annex E(Number of Test Points and Interpolation) |
- |
0 |
|
- |
| Clause 4.6, Annex G(Load Processing Efficiency) |
- |
0 |
|
- |
| Clause 4.7, Annex F(Specified Auxiliaries) |
- |
0 |
|
- |
| Clause 4.8, Annex H(Volume determination) |
- |
0 |
|
- |
| Clause 4.8.1, Annex H(Rated total volume) |
- |
0 |
|
- |
| Clause 5, 5.1, 5.2 Table 1(TARGET TEMPERATURES FOR ENERGY DETERMINATION) |
- |
0 |
|
- |
| Clause 6, 6.1 to 6.8(DETERMINATION OF ENERGY CONSUMPTION) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f 18.11.2025 |
| 7 |
IS 13340 : PART 1 (2024) |
Shunt Power Capacitors of the Self-Healing Type for a.c. Systems Having a Rated Voltage up to and Including 1 000 V Part 1 General - Performance, Testing and Rating - Safety Requirements - Guide for Installation and Operation (Second Revision) |
upto 50kVAr |
249650.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Capacitance measurement and output calculation) |
- |
24000.00 |
|
- |
| 8(Measurement of the tangent of the loss angle (tan δ) of the capacitor) |
- |
11000.00 |
|
- |
| 9(Voltage tests between terminals) |
- |
3000.00 |
|
- |
| 10(Voltage tests between terminals and container) |
- |
3000.00 |
|
- |
| 11(Voltage tests between terminals and container) |
- |
5500.00 |
|
- |
| 12(Sealing test) |
- |
11000.00 |
|
- |
| 13(Thermal stability test) |
- |
24000.00 |
|
- |
| 14("Measurement of the tangent of the loss angle (tan δ) of the capacitor at
elevated temperature") |
- |
24000.00 |
|
- |
| 7(Capacitance measurement and output calculation) |
- |
0 |
|
- |
| 15(Lightning impulse voltage test between terminals and container) |
- |
10000.00 |
|
- |
| 16(Discharge test) |
- |
12000.00 |
|
- |
| 17(Ageing test) |
- |
51150.00 |
|
- |
| 18(Self-healing test) |
- |
11000.00 |
|
- |
| 19(Destruction test) |
- |
31000.00 |
|
- |
| 20(Maximum permissible voltage) |
- |
8000.00 |
|
- |
| 20.1(Long-duration voltages) |
- |
0 |
|
- |
| 20.2(Long-duration voltages) |
- |
0 |
|
- |
| 21(Maximum permissible current) |
- |
8000.00 |
|
- |
| 22(Discharge device) |
- |
5500.00 |
|
- |
| 23("Container connections
") |
- |
5000.00 |
|
- |
| 24(Protection of the environment) |
- |
0 |
|
- |
| 25(Other safety requirements) |
- |
0 |
|
- |
| 26(Marking of the unit) |
- |
1250.00 |
|
- |
| 26.1(Rating plate) |
- |
0 |
|
- |
| 26.2(Standardized connection symbols) |
- |
0 |
|
- |
| 26.3(Warning plate) |
- |
0 |
|
- |
| 27(Marking of the bank) |
- |
1250.00 |
|
- |
| 27.1(Instruction sheet or rating plate) |
- |
0 |
|
- |
| 27.2(Warning plate) |
- |
0 |
|
- |
| 28(General) |
- |
0 |
|
- |
| 29(9 Choice of the rated voltage) |
- |
0 |
|
- |
| 30(Operating temperature) |
- |
0 |
|
- |
| 31(Special service conditions) |
- |
0 |
|
- |
| 32(2 Overvoltages) |
- |
0 |
|
- |
| 33(Overload currents) |
- |
0 |
|
- |
| 34(Switching and protective devices and connections) |
- |
0 |
|
- |
| 36(Capacitors connected to systems with audio-frequency remote control) |
- |
0 |
|
- |
| 36(Capacitors connected to systems with audio-frequency remote control) |
- |
0 |
|
- |
| 37(Electromagnetic compatibility (EMC)) |
- |
0 |
|
- |
| 7(Capacitance measurement and output calculation) |
- |
0 |
|
- |
| 8(Measurement of the tangent of the loss angle (tan δ) of the capacitor) |
- |
0 |
|
- |
| 9(Voltage tests between terminals) |
- |
0 |
|
- |
| 10(Voltage tests between terminals and container) |
- |
0 |
|
- |
| 11(Voltage tests between terminals and container) |
- |
0 |
|
- |
| 12(Sealing test) |
- |
0 |
|
- |
| 13(Thermal stability test) |
- |
0 |
|
- |
| 14("Measurement of the tangent of the loss angle (tan δ) of the capacitor at
elevated temperature") |
- |
0 |
|
- |
| 7(Capacitance measurement and output calculation) |
- |
0 |
|
- |
| 15(Lightning impulse voltage test between terminals and container) |
- |
0 |
|
- |
| 16(Discharge test) |
- |
0 |
|
- |
| 17(Ageing test) |
- |
0 |
|
- |
| 18(Self-healing test) |
- |
0 |
|
- |
| 19(Destruction test) |
- |
0 |
|
- |
| 20(Maximum permissible voltage) |
- |
0 |
|
- |
| 20.1(Long-duration voltages) |
- |
0 |
|
- |
| 20.2(Long-duration voltages) |
- |
0 |
|
- |
| 21(Maximum permissible current) |
- |
0 |
|
- |
| 22(Discharge device) |
- |
0 |
|
- |
| 23("Container connections
") |
- |
0 |
|
- |
| 24(Protection of the environment) |
- |
0 |
|
- |
| 25(Other safety requirements) |
- |
0 |
|
- |
| 26(Marking of the unit) |
- |
0 |
|
- |
| 26.1(Rating plate) |
- |
0 |
|
- |
| 26.2(Standardized connection symbols) |
- |
0 |
|
- |
| 26.3(Warning plate) |
- |
0 |
|
- |
| 27(Marking of the bank) |
- |
0 |
|
- |
| 27.1(Instruction sheet or rating plate) |
- |
0 |
|
- |
| 27.2(Warning plate) |
- |
0 |
|
- |
| 28(General) |
- |
0 |
|
- |
| 29(9 Choice of the rated voltage) |
- |
0 |
|
- |
| 30(Operating temperature) |
- |
0 |
|
- |
| 31(Special service conditions) |
- |
0 |
|
- |
| 32(2 Overvoltages) |
- |
0 |
|
- |
| 33(Overload currents) |
- |
0 |
|
- |
| 34(Switching and protective devices and connections) |
- |
0 |
|
- |
| 36(Capacitors connected to systems with audio-frequency remote control) |
- |
0 |
|
- |
| 36(Capacitors connected to systems with audio-frequency remote control) |
- |
0 |
|
- |
| 37(Electromagnetic compatibility (EMC)) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f. 04.08.2025 |
| 8 |
IS 302 : Part 2 : SEC 31 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 31 range hoods |
- |
54000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
| Clause No - 5.18(linear and angular dimension) |
- |
0 |
|
- |
| Clause No - 6.2(harmfull ingress of water) |
- |
0 |
|
- |
| Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
2000 |
|
- |
| Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
0 |
|
Testing charges included in Clause No - 8.1.1 |
| Clause No - 8.2(Addition) |
- |
0 |
|
Testing charges included in Clause No - 8.1.1 |
| Clause No - 10.1, Table No. -1(power input deviation) |
- |
2000 |
|
- |
| Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
1500 |
|
- |
| Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
1500 |
|
- |
| Clause No - 14(Impulse test voltage) |
- |
2000 |
|
- |
| Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
0 |
|
Testing charges included in Clause No - 15 |
| Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
6000 |
|
- |
| Clause No -19.11.4.1(electrostatic discharge) |
- |
5000 |
|
if applicable (The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be Rs. 55000 charged extra) |
| Clause No -19.11.4.2(radiated field) |
- |
20000 |
|
if applicable |
| Clause No -19.11.4.3(fast transient) |
- |
5000 |
|
if applicable |
| Clause No -19.11.4.4(Voltage dips and interruption) |
- |
5000 |
|
if applicable |
| Clause No -21.1(Mechanical strength) |
- |
3000 |
|
- |
| Clause No -22.1(construction) |
- |
0 |
|
Testing charges included in Clause No - 22 |
| Clause No -22.11(push force applied) |
- |
0 |
|
Testing charges included in Clause No - 22 |
| Clause No -24.1.2(safety isolating transformer) |
- |
0 |
|
Testing charges included in Clause No - 24 |
| Clause No -24.1.3(for switches) |
- |
0 |
|
Testing charges included in Clause No - 24 |
| Clause No -24.1.4(for automatic control) |
- |
0 |
|
Testing charges included in Clause No - 24 |
| Clause No -24.1.5(for innterconnection couplers) |
- |
0 |
|
Testing charges included in Clause No - 24 |
| Clause No -24.4(plug and socket) |
- |
0 |
|
Testing charges included in Clause No - 24 |
| Clause No -25.8, Table no -11(conductor resistance) |
- |
1000 |
|
- |
| Clause No -25.5(dimension for pins) |
- |
0 |
|
Testing charges included in Clause No - 25.8 |
| Clause No -27.6(for circuit board) |
- |
2000 |
|
- |
| Clause No -29.2(comparative tracking index) |
- |
2000 |
|
- |
| Clause No -29.3.3(dry heat test) |
- |
0 |
|
Testing charges included in Clause No - 29.2 |
| Clause No -30.2.1(glow wire test) |
- |
3000 |
|
- |
| Clause No -30.101("incorporate combustible
material") |
- |
0 |
|
Testing charges included in Clause No - 30.2.1 |
| 15(MOISTURE RESISTANCE) |
- |
4000 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
3000 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
5000 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
10000 |
|
if applicable |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
5000 |
|
if applicable |
| 19.11.4.7(Harmonics) |
- |
5000 |
|
if applicable |
| 22(CONSTRUCTION) |
- |
5000 |
|
- |
| 24(COMPONENTS) |
- |
3000 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR
HAZARDS) |
- |
0 |
|
- |
| 11(Heating) |
- |
4000 |
|
- |
| Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
| Clause No - 5.18(linear and angular dimension) |
- |
0 |
|
- |
| Clause No - 6.2(harmfull ingress of water) |
- |
0 |
|
- |
| Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
0 |
|
- |
| Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
0 |
|
- |
| Clause No - 8.2(Addition) |
- |
0 |
|
- |
| Clause No - 10.1, Table No. -1(power input deviation) |
- |
0 |
|
- |
| Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
0 |
|
- |
| Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
0 |
|
- |
| Clause No - 14(Impulse test voltage) |
- |
0 |
|
- |
| Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
0 |
|
- |
| Clause No -19.11.4.1(electrostatic discharge) |
- |
0 |
|
- |
| Clause No -19.11.4.2(radiated field) |
- |
0 |
|
- |
| Clause No -19.11.4.3(fast transient) |
- |
0 |
|
- |
| Clause No -19.11.4.4(Voltage dips and interruption) |
- |
0 |
|
- |
| Clause No -21.1(Mechanical strength) |
- |
0 |
|
- |
| Clause No -22.1(construction) |
- |
0 |
|
- |
| Clause No -22.11(push force applied) |
- |
0 |
|
- |
| Clause No -24.1.2(safety isolating transformer) |
- |
0 |
|
- |
| Clause No -24.1.3(for switches) |
- |
0 |
|
- |
| Clause No -24.1.4(for automatic control) |
- |
0 |
|
- |
| Clause No -24.1.5(for innterconnection couplers) |
- |
0 |
|
- |
| Clause No -24.4(plug and socket) |
- |
0 |
|
- |
| Clause No -25.8, Table no -11(conductor resistance) |
- |
0 |
|
- |
| Clause No -25.5(dimension for pins) |
- |
0 |
|
- |
| Clause No -27.6(for circuit board) |
- |
0 |
|
- |
| Clause No -29.2(comparative tracking index) |
- |
0 |
|
- |
| Clause No -29.3.3(dry heat test) |
- |
0 |
|
- |
| Clause No -30.2.1(glow wire test) |
- |
0 |
|
- |
| Clause No -30.101("incorporate combustible
material") |
- |
0 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
0 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
0 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
0 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 22(CONSTRUCTION) |
- |
0 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR
HAZARDS) |
- |
0 |
|
- |
| 11(Heating) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f 28.07.2025
Exclusion: Cl 22.32 (Construction) Rubber parts oxygen bomb test, Cl 24 (Components) Components testing |
| 9 |
IS 4250 (2025) |
Electric Food-Mixers (Liquidizers and Grinders) and Centrifugal Juicers � Specification ( Second Revision ) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(General Requirements) |
- |
0 |
|
- |
| Cl-5(General Conditions for the tests) |
- |
0 |
|
- |
| Cl-6(Classification) |
- |
0 |
|
- |
| Cl-7(Marking) |
- |
1000 |
|
- |
| Cl-8(Safety Requirements) |
- |
20000 |
|
- |
| Cl-9(Endurance fpr motor and base assembly) |
- |
10000 |
|
- |
| Cl-10.2("Grinding Coffee (for Machines that Have a
Dry Grinding Arrangement)") |
- |
2000 |
|
- |
| Cl-10.3(Whisking Egg Whites (for Machines that have Whisking Egg Arrangement)) |
- |
1000 |
|
- |
| Cl-10.4(Idli Batter) |
- |
1000 |
|
- |
| Cl-10.5(Operational Tests for Juicers) |
- |
2000 |
|
- |
| Cl-11(Temperature Withstand Test for Bowl) |
- |
1000 |
|
- |
| Cl-12.1(Test for Switches) |
- |
1000 |
|
- |
| Cl-13(Strength of Assembly) |
- |
1000 |
|
- |
| Cl-14.2, 14.3 Table-2 (i)(Protection against access to live parts) |
- |
1000 |
|
- |
| Cl-14.2, Table-2 (ii)(Power input and current) |
- |
2000 |
|
- |
| Cl-14.2, 14.3 Table-2 (iii)(Leakage current and electric strength at operating temperature) |
- |
1000 |
|
- |
| Cl-14.2, Table-2 (iv)(Moisture resistance) |
- |
1000 |
|
- |
| Cl-14.2, Table-2 (v)(Leakage current and electric strength) |
- |
1000 |
|
- |
| Cl-14.2, 14.3 Table-2 (vi)(Provision for earthing) |
- |
1000 |
|
- |
| Cl-19.11.4.1(Electrostatic discharges) |
- |
5000 |
|
if applicable (If EMI/EMC (Cl.19.11.4.1 to Cl.19.11.4.7) testing is applicable then Rs. 55000 will be charged extra) |
| Cl-19.11.4.2(Radiated fields) |
- |
20000 |
|
if applicable |
| Cl-19.11.4.3(Fast transient bursts) |
- |
5000 |
|
if applicable |
| Cl-19.11.4.4(Surge immunity test) |
- |
5000 |
|
if applicable |
| Cl-19.11.4.5(Immunity to conducted discharges) |
- |
10000 |
|
if applicable |
| Cl-19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
5000 |
|
if applicable |
| Cl-19.11.4.7(Harmonics) |
- |
5000 |
|
if applicable |
|
20 Jun, 2028 |
- Included w.e.f 28.07.2025
Exclusion: Cl 22.32 (Construction) Rubber parts oxygen bomb test, Cl 24 (Components) Components testing |
| 10 |
IS 17980 (2022) |
Maximum Power Point Tracking Efficiency of Grid Connected Photovoltaic Inverters (First Revision) |
Upto 150kW |
550000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1 (a)(Static MPPT efficiency) |
- |
250000 |
|
- |
| Cl-4.1 (b)(Dynamic MPPT efficiency) |
- |
300000 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f.28.04.2025 |
| 11 |
IS/IEC 61683 (1999) |
Photovoltaic systems - Power conditioners - Procedure for measuring efficiency |
Upto 150kW |
120000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Efficiency calculations) |
- |
50000 |
|
- |
| 6(Efficiency test circuits) |
- |
50000 |
|
- |
| 7(Loss measurement) |
- |
20000 |
|
- |
| Annex A(Power conditioner description) |
- |
0 |
|
- |
| Annex B(Power efficiency and conversion factor) |
- |
0 |
|
- |
| Annex C(Weighted average energy efficiency) |
- |
0 |
|
- |
| Annex D(Derivation of efficiency tolerance in Table 2) |
- |
0 |
|
- |
| 4(Efficiency measurement conditions) |
- |
0 |
|
- |
| 4.1(DC power source for testing) |
- |
0 |
|
- |
| 4.2(Temperature) |
- |
0 |
|
- |
| 4.3(Output voltage and frequency) |
- |
0 |
|
- |
| 4.4(Input voltage) |
- |
0 |
|
- |
| 4.5(Ripple and distortion) |
- |
0 |
|
- |
| 4.6(Resistive loads/utility grid) |
- |
0 |
|
- |
| 4.7(Reactive loads) |
- |
0 |
|
- |
| 4.8(Resistive plus non-linear loads) |
- |
0 |
|
- |
| 4.9(Complex loads) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f.28.04.2025 |
| 12 |
IS 18112 (2022) |
Digital Television Receiver for Satellite Broadcast Transmission Specification |
- |
115000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Marking) |
- |
5000 |
|
- |
| 3.6(Electromagnetic Compatibility (EMC) Requirements) |
- |
110000 |
|
Charges for Radiated and Conducted Emission test |
|
20 Jun, 2028 |
- Included w.e.f.28.04.2025
Only for Cl. 3.6 EMC requirements |
| 13 |
IS 302 : Part 2 : Sec 14 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision) |
- |
69700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
2000 |
|
Testing charges are for Cl. no.7. |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 7.1 |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 7.1 |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 7.1 |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 7.1 |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 7.1 |
| 7.11(Marking- IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 7.1 |
| 7.12(Marking- IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 7.1 |
| 7.13(Marking- IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 7.1 |
| 7.14(Marking- IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 7.1 |
| 7.101(Marking) |
- |
0 |
|
Testing charges are included in Cl. 7.1 |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
2000 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
2000 |
|
- |
| 11(Heating, IS 302-1) |
- |
4000 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
3000 |
|
- |
| 14(Transient Over Voltages, IS 302-1) |
- |
2000 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
4000 |
|
Testing clauses are for Cl. no. 15 |
| 15.2(Moisture Resistance, IS 302-1) |
- |
0 |
|
Testing clauses are included in Cl. no. 15.1 |
| 15(Moisture Resistance, IS 302-1) |
- |
0 |
|
Testing clauses are included in Cl. no. 15.1 |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
3000 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
5000 |
|
- |
| 19.1(Abnormal Operation, IS 302-1) |
- |
6000 |
|
Testing charges are for Cl. no.19 |
| 19.101(Abnormal Operation) |
- |
0 |
|
Testing charges are included in Cl. 19.1 |
| 19.102(Abnormal Operation) |
- |
0 |
|
Testing charges are included in Cl. 19.1 |
| 19.7(Abnormal Operation, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 19.1 |
| 19.8(Abnormal Operation, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 19.1 |
| 19.9(Abnormal Operation, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 19.1 |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
2000 |
|
Testing charges are for Cl. 20 |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 20.1 |
| 20.101(Stability & Mechanical Hazards) |
- |
0 |
|
Testing charges are included in Cl. 20.1 |
| 20.102(Stability & Mechanical Hazards) |
- |
0 |
|
Testing charges are included in Cl. 20.1 |
| 20.103(Stability & Mechanical Hazards) |
- |
0 |
|
Testing charges are included in Cl. 20.1 |
| 20.104(Stability & Mechanical Hazards) |
- |
0 |
|
Testing charges are included in Cl. 20.1 |
| 21.1(Mechanical Strength, IS 302-1) |
- |
2000 |
|
Testing Charges are for Cl. 21 |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 21.1 |
| 22(Construction, IS 302-1) |
- |
3000 |
|
Testing charges are for Cl. 22 |
| 22.101(Construction) |
- |
0 |
|
Testing charges are included in Cl. 22.1 |
| 22.102(Construction) |
- |
0 |
|
Testing charges are included in Cl. 22.1 |
| 23.1(Internal Wiring, IS 302-1) |
- |
2000 |
|
Testing charges are for Cl. 23 |
| 23.2(Internal Wiring, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 23.1 |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 23.1 |
| 23.4(Internal Wiring, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 23.1 |
| 23.5(Internal Wiring, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 23.1 |
| 23.6(Internal Wiring, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 23.1 |
| 23.7(Internal Wiring, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 23.1 |
| 23.8(Internal Wiring, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 23.1 |
| 23.9(Internal Wiring, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 23.1 |
| 23.10(Internal Wiring, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 23.1 |
| 24.1(Components, IS 302-1) |
- |
3000 |
|
Testing charges are for Cl. 24 |
| 24.2(Components, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 24.1 |
| 24.5(Components, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 24.1 |
| 24.6(Components, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 24.1 |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
6000 |
|
Testing charges are for Cl. 25 |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 25.1 |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 25.1 |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 25.1 |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 26.1 |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 25.1 |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 25.1 |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 25.1 |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 25.1 |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 25.1 |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 25.1 |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 25.1 |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 25.1 |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 25.1 |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 25.1 |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 25.1 |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 25.1 |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 25.1 |
| 26(Terminals for External Conductors, IS 302-1) |
- |
1000 |
|
- |
| 27(Provision for Earthing, IS 302-1) |
- |
2000 |
|
Testing charges are for Cl. 27 |
| 27.2(Provision for Earthing, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 27.1 |
| 27.3(Provision for Earthing, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 27.1 |
| 27.4(Provision for Earthing, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 27.1 |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 27.1 |
| 28(Screws & Connections, IS 302-1) |
- |
1000 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
2000 |
|
Testing charges are for Cl. 29 |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 29.1 |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
3000 |
|
Testing charges are for Cl. 30 |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
Testing charges are included in Cl. 30.1 |
| 31(Resistance of Rusting, IS 302-1) |
- |
1000 |
|
- |
| 32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
1000 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
- |
| 20.105(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.106(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.107(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.108(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.109(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.110(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.111(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.112(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.113(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.114(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.115(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.116(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
5000 |
|
If applicable |
| 19.11.4.2(Radiated fields) |
- |
20000 |
|
If applicable |
| 19.11.4.3(Fast transient bursts) |
- |
5000 |
|
If applicable |
| 19.11.4.4(Surge immunity test) |
- |
5000 |
|
If applicable |
| 19.11.4.5(Immunity to conducted discharges) |
- |
10000 |
|
If applicable |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
5000 |
|
If applicable |
| 19.11.4.7(Harmonics) |
- |
5000 |
|
If applicable |
|
20 Jun, 2028 |
- - |
| 14 |
IS 302 : Part 2 : Sec 26 (2014) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 26 clocks (First Revision) |
- |
105000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
1000 |
|
- |
| 8(Protection against live parts) |
- |
2000 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
0 |
|
- |
| 11(HEATING) |
- |
4000 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
3000 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
1000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
4000 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
3000 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
0 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
3000 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
2000 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
2000 |
|
- |
| 22(CONSTRUCTION) |
- |
2000 |
|
- |
| 23(INTERNAL WIRING) |
- |
2000 |
|
- |
| 24(COMPONENTS) |
- |
3000 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
2000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
2000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
2000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
2000 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
2000 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
4000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
1000 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
5000 |
|
If applicable |
| 19.11.4.2(Radiated fields) |
- |
20000 |
|
If applicable |
| 19.11.4.3(Fast transient bursts) |
- |
5000 |
|
If applicable |
| 19.11.4.4(Surge immunity test) |
- |
5000 |
|
If applicable |
| 19.11.4.5(Immunity to conducted discharges) |
- |
10000 |
|
If applicable |
| 19.11.4.6(Voltage dips and interruptions) |
- |
5000 |
|
If applicable |
| 19.11.4.7(Harmonics) |
- |
5000 |
|
If applicable |
|
20 Jun, 2028 |
- - |
| 15 |
IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
- |
71237 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
2000 |
|
- |
| 8(Protection against live parts) |
- |
2000 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
2000 |
|
- |
| 11(HEATING) |
- |
4000 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
3000 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
2000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
3000 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
3000 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
5000 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
6000 |
|
Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be charged extra. |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
2000 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
2000 |
|
- |
| 22(CONSTRUCTION) |
- |
5000 |
|
- |
| 23(INTERNAL WIRING) |
- |
2000 |
|
- |
| 24(COMPONENTS) |
- |
3000 |
|
Above charges applicable excluding the test of clauses mentioned in the list of exclusions. |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
2000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
2000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
2000 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
3000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
1000 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
5000 |
|
-- |
| 19.11.4.2(Radiated fields) |
- |
20000 |
|
-- |
| 19.11.4.3(Fast transient bursts) |
- |
5000 |
|
-- |
| 19.11.4.4(Surge immunity test) |
- |
5000 |
|
-- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
10000 |
|
-- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
5000 |
|
-- |
| 19.11.4.7(Harmonics) |
- |
5000 |
|
-- |
|
20 Jun, 2028 |
- Exclusions: Cord Reel Test (Cl. 22.16), Oxygen bomb test for rubber material (Cl. 22.32), Software (Cl. 22.46), Capacitor Test (Cl. 24.1.1), Switching Cycle Operation Test (Cl. 24.1.3), Automatic Control Cycle Operation Test (Cl. 24.1.4), Appliance Coupler and Interconnection Coupler Test (Cl. 24.1.5), Lamp Holder Test (Cl. 24.1.6), Capacitor in Auxiliary Winding of Motor Test (Cl. 24.5), Motors Basic Insulation Test (Cl. 24.6) |
| 16 |
IS 302 : Part 2 : Sec 35 (2017) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 35 electric instantaneous water heaters (Second Revision) |
- |
71612 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6
IS 302-2-35(Classification) |
- |
0 |
|
- |
| Cl. 7
IS 302-2-35(Marking and Instruction) |
- |
1000 |
|
- |
| Cl. 8
IS 302-2-35(Protection against access to live parts) |
- |
2000 |
|
- |
| Cl. 10
IS 302-2-35(Power Input and Current ) |
- |
3000 |
|
- |
| Cl. 11
IS 302-2-35(Heating) |
- |
5000 |
|
- |
| Cl. 13
IS 302-2-35(Leakage Current & Electric Strength at Operating Temperature) |
- |
4000 |
|
- |
| Cl. 14
IS 302-2-35(Radio and television interference suppression / Transient over voltages) |
- |
2000 |
|
- |
| Cl. 15
IS 302-2-35(Moisture Resistance Test ) |
- |
5000 |
|
- |
| Cl. 16
IS 302-2-35(Leakage Current & Electric Strength at Operating Temperature (After Humidity Treatment)) |
- |
4000 |
|
- |
| Cl. 17
IS 302-2-35(Overload Protection of Transformers and Associated Circuit) |
- |
2000 |
|
- |
| Cl. 19
IS 302-2-35(Abnormal Operation ) |
- |
5000 |
|
- |
| Cl. 20
IS 302-2-35(Stability & Mechanical Hazards) |
- |
2000 |
|
- |
| Cl. 21
IS 302-2-35(Mechanical strength) |
- |
2000 |
|
- |
| Cl. 22
IS 302-2-35(Construction ) |
- |
3000 |
|
- |
| Cl. 23
IS 302-2-35(Internal Wiring) |
- |
1000 |
|
- |
| Cl. 24
IS 302-2-35(Components) |
- |
2000 |
|
- |
| Cl. 25
IS 302-2-35(Supply Connection & External Flexible Cords) |
- |
2000 |
|
- |
| Cl. 26
IS 302-2-35(Terminals for External conductors ) |
- |
1000 |
|
- |
| Cl. 27
IS 302-2-35(Provision for Earthing ) |
- |
3000 |
|
- |
| Cl. 28
IS 302-2-35(Screws & Connections) |
- |
1000 |
|
- |
| Cl. 29
IS 302-2-35(Clearances, Creepage Distances & Solid insulation ) |
- |
2000 |
|
- |
| Cl. 30
IS 302-2-35(Resistance to Heat Fire & Tracking ) |
- |
4000 |
|
- |
| Cl. 31
IS 302-2-35(Resistance to Rusting) |
- |
1000 |
|
- |
| Cl. 32
IS 302-2-35(Radiation, Toxicity and similar hazards) |
- |
1000 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
5000 |
|
if applicable |
| 19.11.4.2(Radiated fields) |
- |
20000 |
|
if applicable |
| 19.11.4.3(Fast transient bursts) |
- |
5000 |
|
if applicable |
| 19.11.4.4(Surge immunity test) |
- |
5000 |
|
if applicable |
| 19.11.4.5(Immunity to conducted discharges) |
- |
10000 |
|
if applicable |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
5000 |
|
if applicable |
| 19.11.4.7(Harmonics) |
- |
5000 |
|
if applicable |
|
20 Jun, 2028 |
- - |
| 17 |
IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
- |
60000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
0 |
|
- |
| 7.0(Marking and instructions) |
- |
2000 |
|
- |
| 8.0(Protection against access to live part test) |
- |
2000 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
0 |
|
- |
| 10.0(Power Input and current test) |
- |
2000 |
|
- |
| 11.0(Heating test) |
- |
4000 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
3000 |
|
- |
| 14.0(Transient voltages) |
- |
2000 |
|
- |
| 15.0(Moisture Resistance) |
- |
4000 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
3000 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
5000 |
|
- |
| 19.0(Abnormal Operations) |
- |
6000 |
|
Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be Rs. 55000 charged extra. |
| 20.0(Stability and Mechanical Hazards) |
- |
2000 |
|
- |
| 21.0(Mechanical Strength) |
- |
3000 |
|
- |
| 22.0(Construction verification related tests) |
- |
5000 |
|
- |
| 23.0(Internal wiring) |
- |
2000 |
|
- |
| 24.0(Components) |
- |
3000 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
1000 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
1000 |
|
- |
| 27.0(Provision for Earthing) |
- |
2000 |
|
- |
| 28.0(Screws and connections) |
- |
1000 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
2000 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
3000 |
|
- |
| 31.0(Resistance to rusting) |
- |
1000 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
5000 |
|
If applicable |
| 19.11.4.2(Radiated fields) |
- |
20000 |
|
If applicable |
| 19.11.4.3(Fast transient bursts) |
- |
5000 |
|
If applicable |
| 19.11.4.4(Surge immunity test) |
- |
5000 |
|
If applicable |
| 19.11.4.5(Immunity to conducted discharges) |
- |
10000 |
|
If applicable |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
5000 |
|
If applicable |
| 19.11.4.7(Harmonics) |
- |
5000 |
|
If applicable |
| 18.0(Endurance test) |
- |
0 |
|
- |
| 4(General Requirements) |
- |
0 |
|
- |
| 5(General condition for the tests) |
- |
0 |
|
- |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
1000 |
|
- |
| 6.0(Classification) |
- |
0 |
|
- |
| 7.0(Marking and instructions) |
- |
0 |
|
- |
| 8.0(Protection against access to live part test) |
- |
0 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
0 |
|
- |
| 10.0(Power Input and current test) |
- |
0 |
|
- |
| 11.0(Heating test) |
- |
0 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
0 |
|
- |
| 14.0(Transient voltages) |
- |
0 |
|
- |
| 15.0(Moisture Resistance) |
- |
0 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
0 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
0 |
|
- |
| 19.0(Abnormal Operations) |
- |
0 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
0 |
|
- |
| 21.0(Mechanical Strength) |
- |
0 |
|
- |
| 22.0(Construction verification related tests) |
- |
0 |
|
- |
| 23.0(Internal wiring) |
- |
0 |
|
- |
| 24.0(Components) |
- |
0 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
0 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
0 |
|
- |
| 27.0(Provision for Earthing) |
- |
0 |
|
- |
| 28.0(Screws and connections) |
- |
0 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
0 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
0 |
|
- |
| 31.0(Resistance to rusting) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 18.0(Endurance test) |
- |
0 |
|
- |
| 4(General Requirements) |
- |
0 |
|
- |
| 5(General condition for the tests) |
- |
0 |
|
- |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
0 |
|
- |
| 6.0(Classification) |
- |
0 |
|
- |
| 7.0(Marking and instructions) |
- |
0 |
|
- |
| 8.0(Protection against access to live part test) |
- |
0 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
0 |
|
- |
| 10.0(Power Input and current test) |
- |
0 |
|
- |
| 11.0(Heating test) |
- |
0 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
0 |
|
- |
| 14.0(Transient voltages) |
- |
0 |
|
- |
| 15.0(Moisture Resistance) |
- |
0 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
0 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
0 |
|
- |
| 19.0(Abnormal Operations) |
- |
0 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
0 |
|
- |
| 21.0(Mechanical Strength) |
- |
0 |
|
- |
| 22.0(Construction verification related tests) |
- |
0 |
|
- |
| 23.0(Internal wiring) |
- |
0 |
|
- |
| 24.0(Components) |
- |
0 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
0 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
0 |
|
- |
| 27.0(Provision for Earthing) |
- |
0 |
|
- |
| 28.0(Screws and connections) |
- |
0 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
0 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
0 |
|
- |
| 31.0(Resistance to rusting) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 18.0(Endurance test) |
- |
0 |
|
- |
| 4(General Requirements) |
- |
0 |
|
- |
| 5(General condition for the tests) |
- |
0 |
|
- |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f.28.04.2025
Exclusion
Cl. No. 22.32 Rubber parts test, Cl. No. 22.16 Cord reel test, 24.0 (Components) |
| 18 |
IS 302 : Part 2 : Sec 45 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 45 electric heating tools |
- |
54000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Rating) |
- |
0 |
|
- |
| 6(Classification) |
- |
0 |
|
- |
| 7(Marking) |
- |
1000 |
|
- |
| 8(Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 10("Power Input
& Current") |
- |
2000 |
|
- |
| 11(Temperature Rise/ Heating) |
- |
4000 |
|
- |
| 12(Operation Under Overload Condition) |
- |
0 |
|
- |
| 13(Electric Insulation at Operating Temperature) |
- |
3000 |
|
- |
| 14("Radio and Television Interference Suppression / Transient Over Voltage
") |
- |
2000 |
|
- |
| 15(Moisture Resistance) |
- |
4000 |
|
- |
| 16(Insulation Resistance and Electric Strength/ Leakage Current and Electric Strength (After Humidity Treatment)) |
- |
3000 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
4000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
4000 |
|
Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be Rs. 55000 charged extra. |
| 20(Stability & Mechanical Hazards) |
- |
2000 |
|
- |
| 21(Mechanical strength) |
- |
2000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal Wiring) |
- |
2000 |
|
- |
| 24(Components) |
- |
2000 |
|
- |
| 25(Supply Connection & External Flexible Cords) |
- |
2000 |
|
- |
| 26(Terminals For External Conductors) |
- |
1000 |
|
- |
| 27(Provision For Earthing) |
- |
2000 |
|
- |
| 28(Screws & Connections) |
- |
1000 |
|
- |
| 29(Creepage Distances & Clearances) |
- |
2000 |
|
- |
| 30(Resistance to Heat, Fire and Tracking) |
- |
3000 |
|
- |
| 31(Radiation hazards) |
- |
0 |
|
Testing charges included in Cl.XXV of Table 101 (Resistance to Rusting) |
| XXV of Table 101(Resistance to Rusting) |
- |
1000 |
|
- |
| 4(General Requirement) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
5000 |
|
if applicable |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
5000 |
|
if applicable |
| 19.11.4.5(Immunity to conducted discharges) |
- |
10000 |
|
if applicable |
| 19.11.4.4(Surge immunity test) |
- |
5000 |
|
if applicable |
| 19.11.4.3(Fast transient bursts) |
- |
5000 |
|
if applicable |
| 19.11.4.2(Radiated fields) |
- |
20000 |
|
if applicable |
| 19.11.4.1(Electrostatic discharges) |
- |
5000 |
|
if applicable |
|
20 Jun, 2028 |
- Included w.e.f 25.03.2025
Exclusion Cl 24 (Components) |
| 19 |
IS 302 : Part 2 : Sec 12 (1993) |
Safety of household and similar electrical appliances - Specification: Part 2 particular requirements: Sec 12 warming plates and similar appliances |
- |
56000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Rating) |
- |
0 |
|
- |
| 6(Classification) |
- |
0 |
|
- |
| 7(Marking) |
- |
1000 |
|
- |
| 8(Protection against Access to Live Parts) |
- |
2000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 10("Power Input
& Current") |
- |
2000 |
|
- |
| 11(Temperature Rise/ Heating) |
- |
4000 |
|
- |
| 12(Operation Under Overload Conditions of Appliances with heating Element) |
- |
0 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
3000 |
|
- |
| 14("Radio and Television Interference Suppression / Transient Over Voltage
") |
- |
2000 |
|
- |
| 15(Moisture Resistance) |
- |
4000 |
|
- |
| 16(Insulation Resistance and Electric Strength/ Leakage Current and Electric Strength) |
- |
3000 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
4000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be Rs. 55000 charged extra. |
| 20(Stability & Mechanical Hazards) |
- |
2000 |
|
- |
| 21(Mechanical strength) |
- |
2000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal Wiring) |
- |
2000 |
|
- |
| 24(Components) |
- |
3000 |
|
- |
| 25(Supply Connection & External Flexible Cords) |
- |
2000 |
|
- |
| 26(Terminals For External Conductors) |
- |
1000 |
|
- |
| 27(Provision For Earthing) |
- |
2000 |
|
- |
| 28(Screws & Connections) |
- |
1000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
2000 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
3000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 32(Radiation hazards) |
- |
0 |
|
- |
| 5(Rating) |
- |
0 |
|
- |
| 6(Classification) |
- |
0 |
|
- |
| 7(Marking) |
- |
0 |
|
- |
| 8(Protection against Access to Live Parts) |
- |
0 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 10("Power Input
& Current") |
- |
0 |
|
- |
| 11(Temperature Rise/ Heating) |
- |
0 |
|
- |
| 12(Operation Under Overload Conditions of Appliances with heating Element) |
- |
0 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
0 |
|
- |
| 14("Radio and Television Interference Suppression / Transient Over Voltage
") |
- |
0 |
|
- |
| 15(Moisture Resistance) |
- |
0 |
|
- |
| 16(Insulation Resistance and Electric Strength/ Leakage Current and Electric Strength) |
- |
0 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 23(Internal Wiring) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 25(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
| 26(Terminals For External Conductors) |
- |
0 |
|
- |
| 27(Provision For Earthing) |
- |
0 |
|
- |
| 28(Screws & Connections) |
- |
0 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
0 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 32(Radiation hazards) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
5000 |
|
If applicable |
| 19.11.4.2(Radiated fields) |
- |
20000 |
|
If applicable |
| 19.11.4.3(Fast transient bursts) |
- |
5000 |
|
If applicable |
| 19.11.4.4(Surge immunity test) |
- |
5000 |
|
If applicable |
| 19.11.4.5(Immunity to conducted discharges) |
- |
10000 |
|
If applicable |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
5000 |
|
If applicable |
| 19.11.4.7(Harmonics) |
- |
5000 |
|
If applicable |
|
20 Jun, 2028 |
- Included w.e.f.20.05.2025
Exclusion
Cl. No. 22.32 Rubber parts test
24 (Components) |
| 20 |
IS 302 : Part 2 : Sec 74 (2024) |
Household and Similar Electrical Appliances�Safety Part 2 Particular Requirements Section 74 Portable immersion heaters |
- |
66000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
2000 |
|
- |
| 8(Protection against access to live parts) |
- |
2000 |
|
- |
| 10(Power input and current) |
- |
2000 |
|
- |
| 10(Power input and current) |
- |
0 |
|
Testing charges included in Cl.10 |
| 11(Heating) |
- |
4000 |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
1500 |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
1500 |
|
- |
| 14(Transient overvoltages) |
- |
2000 |
|
- |
| 15(Moisture resistance) |
- |
4000 |
|
- |
| 15.3(Moisture resistance) |
- |
0 |
|
Testing charges included in Cl.15 |
| 16.1 &16.2(Leakage current test) |
- |
1500 |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
1500 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
4000 |
|
- |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
8000 |
|
Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be Rs. 55000 charged extra. |
| 20.1(Stability and mechanical hazards) |
- |
2000 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
0 |
|
Testing charges included in Cl.20.1 |
| 21(Mechanical strength) |
- |
3000 |
|
- |
| 22(Construction) |
- |
8000 |
|
- |
| 23(Internal wiring) |
- |
2000 |
|
- |
| 24(Components) |
- |
3000 |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
1000 |
|
- |
| 26("Terminals for external
conductors") |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
2000 |
|
- |
| 28(Screws and connections) |
- |
1000 |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
2000 |
|
- |
| 30(Resistance to heat and fire) |
- |
3000 |
|
- |
| 30.101(Resistance to heat and fire) |
- |
0 |
|
Testing charges included in Cl.30 |
| 31(Resistance to rusting) |
- |
1000 |
|
- |
| 32("Radiation, toxicity and similar
hazards") |
- |
1000 |
|
- |
| Cl 19.11.4.1(Electrostatic discharges) |
- |
5000 |
|
if applicable |
| Cl 19.11.4.2(Radiated fields) |
- |
20000 |
|
if applicable |
| Cl 19.11.4.3(Fast transient bursts) |
- |
5000 |
|
if applicable |
| Cl 19.11.4.4(Voltage surges) |
- |
5000 |
|
if applicable |
| Cl 19.11.4.5(Immunity to conducted disturbances) |
- |
10000 |
|
if applicable |
| Cl 19.11.4.6(Voltage dips and interruptions) |
- |
5000 |
|
if applicable |
| Cl 19.11.4.7(Harmonics and inter-harmonics) |
- |
5000 |
|
if applicable |
| Cl 19.11.4.8(Abnormal operation) |
- |
5000 |
|
- |
| 24.101(Components) |
- |
0 |
|
Testing charges included in Cl.24 |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8(Protection against access to live parts) |
- |
0 |
|
- |
| 10(Power input and current) |
- |
0 |
|
- |
| 10(Power input and current) |
- |
0 |
|
- |
| 11(Heating) |
- |
0 |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
0 |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
0 |
|
- |
| 14(Transient overvoltages) |
- |
0 |
|
- |
| 15(Moisture resistance) |
- |
0 |
|
- |
| 15.3(Moisture resistance) |
- |
0 |
|
- |
| 16.1 &16.2(Leakage current test) |
- |
0 |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
0 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
0 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
0 |
|
- |
| 26("Terminals for external
conductors") |
- |
0 |
|
- |
| 27(Provision for earthing) |
- |
0 |
|
- |
| 28(Screws and connections) |
- |
0 |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
0 |
|
- |
| 30(Resistance to heat and fire) |
- |
0 |
|
- |
| 30.101(Resistance to heat and fire) |
- |
0 |
|
- |
| 31(Resistance to rusting) |
- |
0 |
|
- |
| 32("Radiation, toxicity and similar
hazards") |
- |
0 |
|
- |
| Cl 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| Cl 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| Cl 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| Cl 19.11.4.4(Voltage surges) |
- |
0 |
|
- |
| Cl 19.11.4.5(Immunity to conducted disturbances) |
- |
0 |
|
- |
| Cl 19.11.4.6(Voltage dips and interruptions) |
- |
0 |
|
- |
| Cl 19.11.4.7(Harmonics and inter-harmonics) |
- |
0 |
|
- |
| Cl 19.11.4.8(Abnormal operation) |
- |
0 |
|
- |
| 24.101(Components) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f 25.03.2025
Exclusion:Cl 24 (Components), Cl 32 ("Radiation, toxicity and similar hazards") |
| 21 |
IS 302 : Part 2 : Sec 42 (2024) |
Household and Similar Electrical Appliances�Safety Part 2 Particular Requirements Section 42 Commercial electric forced convection ovens, steam cookers and steam-convection ovens |
- |
66000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
2000 |
|
- |
| 8(Protection against access to live parts) |
- |
2000 |
|
- |
| 10(Power input and current) |
- |
2000 |
|
- |
| 11(Heating) |
- |
4000 |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
1500 |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
1500 |
|
- |
| 14(Transient overvoltages) |
- |
2000 |
|
- |
| 15(Moisture resistance) |
- |
4000 |
|
- |
| 15.3(Moisture resistance) |
- |
0 |
|
Testing charges included in Cl.15 |
| 15.101(Moisture resistance) |
- |
0 |
|
Testing charges included in Cl.15 |
| 16.1 &16.2(Leakage current test) |
- |
1500 |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
1500 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
4000 |
|
- |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
8000 |
|
Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be Rs. 55000 charged extra. |
| 19.101(Abnormal operation) |
- |
0 |
|
Testing charges included in Cl.19.1 to CL.19.13 |
| 20.1(Stability and mechanical hazards) |
- |
2000 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
0 |
|
Testing charges included in Cl.20.1 |
| 20.101(Stability and mechanical hazards) |
- |
0 |
|
Testing charges included in Cl.20.1 |
| 20.102(Stability and mechanical hazards) |
- |
0 |
|
Testing charges included in Cl.20.1 |
| 21(Mechanical strength) |
- |
3000 |
|
- |
| 21.101(Mechanical strength) |
- |
0 |
|
Testing charges included in Cl.21 |
| 22(Construction) |
- |
8000 |
|
- |
| 22.101(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.102(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.103(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.104(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.105(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.106(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.107(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.108(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.109(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.110(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.111(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.112(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.113(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.114(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.115(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.116(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.117(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.118(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.119(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 23(Internal wiring) |
- |
2000 |
|
- |
| 24(Components) |
- |
3000 |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
1000 |
|
- |
| 26("Terminals for external
conductors") |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
2000 |
|
- |
| 28(Screws and connections) |
- |
1000 |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
2000 |
|
- |
| 30(Resistance to heat and fire) |
- |
3000 |
|
- |
| 31(Resistance to rusting) |
- |
1000 |
|
- |
| 32("Radiation, toxicity and similar
hazards") |
- |
1000 |
|
- |
| 22.109(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 30.101(Resistance to heat and fire) |
- |
0 |
|
Testing charges included in Cl.30 |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8(Protection against access to live parts) |
- |
0 |
|
- |
| 10(Power input and current) |
- |
0 |
|
- |
| 11(Heating) |
- |
0 |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
0 |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
0 |
|
- |
| 14(Transient overvoltages) |
- |
0 |
|
- |
| 15(Moisture resistance) |
- |
0 |
|
- |
| 15.3(Moisture resistance) |
- |
0 |
|
- |
| 15.101(Moisture resistance) |
- |
0 |
|
- |
| 16.1 &16.2(Leakage current test) |
- |
0 |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
0 |
|
- |
| 19.101(Abnormal operation) |
- |
0 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
0 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
0 |
|
- |
| 20.101(Stability and mechanical hazards) |
- |
0 |
|
- |
| 20.102(Stability and mechanical hazards) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 21.101(Mechanical strength) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 22.101(Construction) |
- |
0 |
|
- |
| 22.102(Construction) |
- |
0 |
|
- |
| 22.103(Construction) |
- |
0 |
|
- |
| 22.104(Construction) |
- |
0 |
|
- |
| 22.105(Construction) |
- |
0 |
|
- |
| 22.106(Construction) |
- |
0 |
|
- |
| 22.107(Construction) |
- |
0 |
|
- |
| 22.108(Construction) |
- |
0 |
|
- |
| 22.109(Construction) |
- |
0 |
|
- |
| 22.110(Construction) |
- |
0 |
|
- |
| 22.111(Construction) |
- |
0 |
|
- |
| 22.112(Construction) |
- |
0 |
|
- |
| 22.113(Construction) |
- |
0 |
|
- |
| 22.114(Construction) |
- |
0 |
|
- |
| 22.115(Construction) |
- |
0 |
|
- |
| 22.116(Construction) |
- |
0 |
|
- |
| 22.117(Construction) |
- |
0 |
|
- |
| 22.118(Construction) |
- |
0 |
|
- |
| 22.119(Construction) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
0 |
|
- |
| 26("Terminals for external
conductors") |
- |
0 |
|
- |
| 27(Provision for earthing) |
- |
0 |
|
- |
| 28(Screws and connections) |
- |
0 |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
0 |
|
- |
| 30(Resistance to heat and fire) |
- |
0 |
|
- |
| 31(Resistance to rusting) |
- |
0 |
|
- |
| 32("Radiation, toxicity and similar
hazards") |
- |
0 |
|
- |
| 22.109(Construction) |
- |
0 |
|
- |
| 30.101(Resistance to heat and fire) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f 25.03.2025
Exclusion: Cl 24 (Components), Cl 32 ("Radiation, toxicity and similar hazards") |
| 22 |
IS 302 : Part 2 : Sec 13 (2024) |
Household and Similar Electrical Appliances —Safety Part 2 Particular Requirements Section 13 Deep Fat Fryers, Frying Pans and Similar Appliances (First Revision) |
- |
66000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
2000 |
|
- |
| 8(Protection against access to live parts) |
- |
2000 |
|
- |
| 10(Power input and current) |
- |
2000 |
|
- |
| 11(Heating) |
- |
4000 |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
1500 |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
1500 |
|
- |
| 14(Transient overvoltages) |
- |
2000 |
|
- |
| 15(Moisture resistance) |
- |
4000 |
|
- |
| 15.3(Moisture resistance) |
- |
0 |
|
Testing charges included in Cl.15 |
| 15.101(Moisture resistance) |
- |
0 |
|
Testing charges included in Cl.15 |
| 16.1 &16.2(Leakage current test) |
- |
1500 |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
1500 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
4000 |
|
- |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
8000 |
|
Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be charged extra. |
| 19.101 to to 19.102(Abnormal operation) |
- |
0 |
|
Testing charges included in Cl.19.1 to CL.19.13 |
| 20(Stability and mechanical hazards) |
- |
2000 |
|
- |
| 21(Mechanical strength) |
- |
3000 |
|
- |
| 22(Construction) |
- |
8000 |
|
- |
| 22.101(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 23(Internal wiring) |
- |
2000 |
|
- |
| 24(Components) |
- |
3000 |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
1000 |
|
- |
| 26("Terminals for external
conductors") |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
2000 |
|
- |
| 28(Screws and connections) |
- |
1000 |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
2000 |
|
- |
| 30(Resistance to heat and fire) |
- |
3000 |
|
- |
| 31(Resistance to rusting) |
- |
1000 |
|
- |
| 32("Radiation, toxicity and similar
hazards") |
- |
1000 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f 25.03.2025
Exclusion: Cl 24 (Components), Cl 32 ("Radiation, toxicity and similar hazards") |
| 23 |
IS 302 : Part 2 : Sec 8 (2024) |
Household and Similar Electrical Appliances —Safety Part 2 Particular Requirements Section 8 Shavers, Hair Clippers and Similar Appliances (First Revision) |
- |
73000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
2000 |
|
- |
| 8(Protection against access to live parts) |
- |
2000 |
|
- |
| 10(Power input and current) |
- |
2000 |
|
- |
| 11(Heating) |
- |
4000 |
|
- |
| 12(Charging of metal-ion batteries) |
- |
15000 |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
1500 |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
1500 |
|
- |
| 14(Transient overvoltages) |
- |
2000 |
|
- |
| 15(Moisture resistance) |
- |
2000 |
|
- |
| 15.3(Moisture resistance) |
- |
2000 |
|
- |
| 16.1 &16.2(Leakage current test) |
- |
1500 |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
1500 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
4000 |
|
- |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
5000 |
|
Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be charged extra. |
| 19.101(Abnormal operation) |
- |
0 |
|
Testing charges included in Cl.19.1 TO cL.19.13 |
| 20.1(Stability and mechanical hazards) |
- |
1000 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
1000 |
|
- |
| 21(Mechanical strength) |
- |
3000 |
|
- |
| 21.101(Mechanical strength) |
- |
0 |
|
Testing charges included in Cl.21 |
| 21.102(Mechanical strength) |
- |
0 |
|
Testing charges included in Cl.21 |
| 21.103(Mechanical strength) |
- |
0 |
|
Testing charges included in Cl.21 |
| 22(Construction) |
- |
5000 |
|
- |
| 22.101(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.102(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.103(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 23(Internal wiring) |
- |
2000 |
|
- |
| 24(Components) |
- |
3000 |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
1000 |
|
- |
| 26("Terminals for external
conductors") |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
2000 |
|
- |
| 28(Screws and connections) |
- |
1000 |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
2000 |
|
- |
| 30(Resistance to heat and fire) |
- |
3000 |
|
- |
| 31(Resistance to rusting) |
- |
1000 |
|
- |
| 32("Radiation, toxicity and similar
hazards") |
- |
1000 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f 25.03.2025
Exclusion : Cl 24 (Components), Cl 32 ("Radiation, toxicity and similar hazards") |
| 24 |
IS 302 : Part 1 (2024) |
Household and Similar Electrical Appliances — Safety Part 1 General Requirements (Seventh Revision) |
- |
73000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General requirement) |
- |
0 |
|
- |
| 5(General conditions for the tests) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
2000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
2000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
0 |
|
Testing charges included in Cl.8.1.1 |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
Testing charges included in Cl.8.1.1 |
| 8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
Testing charges included in Cl.8.1.1 |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
Testing charges included in Cl.8.1.1 |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
| 10.1(Power input) |
- |
2000 |
|
- |
| 10.2(Current input) |
- |
0 |
|
Testing charges included in Cl.10.1 |
| 11.1(General) |
- |
4000 |
|
- |
| 11.2(General) |
- |
0 |
|
Testing charges included in Cl.11.1 |
| 11.3(Heating) |
- |
0 |
|
Testing charges included in Cl.11.1 |
| 11.4(Heating appliances) |
- |
0 |
|
Testing charges included in Cl.11.1 |
| 11.5(Motor-operated appliances) |
- |
0 |
|
Testing charges included in Cl.11.1 |
| 11.6(Combined appliances) |
- |
0 |
|
Testing charges included in Cl.11.1 |
| 11.7(Duration corresponding) |
- |
0 |
|
Testing charges included in Cl.11.1 |
| 11.8(Temperature rise) |
- |
0 |
|
Testing charges included in Cl.11.1 |
| 12(Charging of metal-ion batteries) |
- |
15000 |
|
if applicable |
| 13(Leakage current and electric strength at operating temperature) |
- |
3000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
0 |
|
Testing charges included in Cl.13 |
| 13.3(Electric Strength at operating temperature) |
- |
0 |
|
Testing charges included in Cl.13 |
| 14(Transient Over Voltages) |
- |
2000 |
|
- |
| 15.0(Moisture resistance) |
- |
4000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
0 |
|
Testing charges included in Cl.15 |
| 15.2(Spillage Test) |
- |
0 |
|
Testing charges included in Cl.15 |
| 15.3(Humidity Test) |
- |
0 |
|
Testing charges included in Cl.15 |
| 16.0(General) |
- |
0 |
|
Testing charges included in Cl.16 |
| 16(Leakage current and electric strength) |
- |
3000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
Testing charges included in Cl.16 |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
Testing charges included in Cl.16 |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
4000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
Testing charges included in Cl.17 |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. The testing charges for EMI/EMC testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be applicable |
| 19.17(Abnormal Operation, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.19 |
| 19.11.4.1(Electrostatic discharges) |
- |
5000 |
|
Complete testing Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. If applicable, The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be charged extra |
| 19.11.4.2(Radiated fields) |
- |
20000 |
|
Complete testing Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. If applicable, The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be charged extra |
| 19.11.4.3(Fast transient bursts) |
- |
5000 |
|
Complete testing Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. If applicable, The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be charged extra |
| 19.11.4.4(Surge immunity test) |
- |
5000 |
|
Complete testing Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. If applicable, The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be charged extra |
| 19.11.4.5(Immunity to conducted discharges) |
- |
10000 |
|
Complete testing Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. If applicable, The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be charged extra |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
5000 |
|
Complete testing Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. If applicable, The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be charged extra |
| 19.11.4.7(Harmonics) |
- |
5000 |
|
Complete testing Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. If applicable, The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be charged extra |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
2000 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.20 |
| 21.1(Mechanical Strength, IS 302-1) |
- |
3000 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.21 |
| 21.3(Mechanical Strength, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.21 |
| 22.1(Construction, IS 302-1) |
- |
5000 |
|
- |
| 22.5(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.6(Construction, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.11(Construction, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.16(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.32(Construction, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.42(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 23.1(Internal Wiring, IS 302-1) |
- |
2000 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.23 |
| 24(Components) |
- |
3000 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.25 |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.25 |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.25 |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.25 |
| 26(Terminals for external conductors) |
- |
1000 |
|
- |
| 26.5(Terminals for external conductors) |
- |
0 |
|
Testing charges included in Cl.26 |
| 27.1(Provision for Earthing, IS 302-1) |
- |
2000 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.27 |
| 28(Screw test and connections) |
- |
1000 |
|
- |
| 28.1(Screws and connections) |
- |
0 |
|
Testing charges included in Cl.28 |
| 29(clearance, creepage distances and solid insulation) |
- |
2000 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 32.1(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| A.2(Earth continuity test) |
- |
0 |
|
Testing charges included in Cl.27 |
| 22.2(Construction, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.3(Construction, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.22 |
| B.22.4(Construction, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.22 |
| B.22.5(Construction, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.22 |
| Annex C(Ageing test on motors) |
- |
0 |
|
- |
| Annex D(Thermal motor protectors) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 16.1(General) |
- |
0 |
|
Testing charges included in Cl.16 |
| 15.2(Moisture resistance) |
- |
0 |
|
Testing charges included in Cl.15 |
| 4(General requirement) |
- |
0 |
|
- |
| 5(General conditions for the tests) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
0 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
0 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
| 10.1(Power input) |
- |
0 |
|
- |
| 10.2(Current input) |
- |
0 |
|
- |
| 11.1(General) |
- |
0 |
|
- |
| 11.2(General) |
- |
0 |
|
- |
| 11.3(Heating) |
- |
0 |
|
- |
| 11.4(Heating appliances) |
- |
0 |
|
- |
| 11.5(Motor-operated appliances) |
- |
0 |
|
- |
| 11.6(Combined appliances) |
- |
0 |
|
- |
| 11.7(Duration corresponding) |
- |
0 |
|
- |
| 11.8(Temperature rise) |
- |
0 |
|
- |
| 12(Charging of metal-ion batteries) |
- |
0 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
0 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
0 |
|
- |
| 14(Transient Over Voltages) |
- |
0 |
|
- |
| 15.0(Moisture resistance) |
- |
0 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
0 |
|
- |
| 15.2(Spillage Test) |
- |
0 |
|
- |
| 15.3(Humidity Test) |
- |
0 |
|
- |
| 16.0(General) |
- |
0 |
|
- |
| 16(Leakage current and electric strength) |
- |
0 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 19.17(Abnormal Operation, IS 302-1) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.3(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.5(Construction) |
- |
0 |
|
- |
| 22.6(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.11(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.16(Construction) |
- |
0 |
|
- |
| 22.32(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.42(Construction) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
0 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26(Terminals for external conductors) |
- |
0 |
|
- |
| 26.5(Terminals for external conductors) |
- |
0 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28(Screw test and connections) |
- |
0 |
|
- |
| 28.1(Screws and connections) |
- |
0 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
0 |
|
- |
| 30.1(Ball pressure test) |
- |
0 |
|
- |
| 30.2(Glow Wire Test) |
- |
0 |
|
- |
| 30.2(Needle Flame Test) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 32.1(Radiation Toxicity and Similar Hazards) |
- |
0 |
|
- |
| A.2(Earth continuity test) |
- |
0 |
|
- |
| 22.2(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.3(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.4(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.5(Construction, IS 302-1) |
- |
0 |
|
- |
| Annex C(Ageing test on motors) |
- |
0 |
|
- |
| Annex D(Thermal motor protectors) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 16.1(General) |
- |
0 |
|
- |
| 15.2(Moisture resistance) |
- |
0 |
|
- |
| 4(General requirement) |
- |
0 |
|
- |
| 5(General conditions for the tests) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
0 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
0 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
| 10.1(Power input) |
- |
0 |
|
- |
| 10.2(Current input) |
- |
0 |
|
- |
| 11.1(General) |
- |
0 |
|
- |
| 11.2(General) |
- |
0 |
|
- |
| 11.3(Heating) |
- |
0 |
|
- |
| 11.4(Heating appliances) |
- |
0 |
|
- |
| 11.5(Motor-operated appliances) |
- |
0 |
|
- |
| 11.6(Combined appliances) |
- |
0 |
|
- |
| 11.7(Duration corresponding) |
- |
0 |
|
- |
| 11.8(Temperature rise) |
- |
0 |
|
- |
| 12(Charging of metal-ion batteries) |
- |
0 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
0 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
0 |
|
- |
| 14(Transient Over Voltages) |
- |
0 |
|
- |
| 15.0(Moisture resistance) |
- |
0 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
0 |
|
- |
| 15.2(Spillage Test) |
- |
0 |
|
- |
| 15.3(Humidity Test) |
- |
0 |
|
- |
| 16.0(General) |
- |
0 |
|
- |
| 16(Leakage current and electric strength) |
- |
0 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 19.17(Abnormal Operation, IS 302-1) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.3(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.5(Construction) |
- |
0 |
|
- |
| 22.6(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.11(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.16(Construction) |
- |
0 |
|
- |
| 22.32(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.42(Construction) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
0 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26(Terminals for external conductors) |
- |
0 |
|
- |
| 26.5(Terminals for external conductors) |
- |
0 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28(Screw test and connections) |
- |
0 |
|
- |
| 28.1(Screws and connections) |
- |
0 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
0 |
|
- |
| 30.1(Ball pressure test) |
- |
0 |
|
- |
| 30.2(Glow Wire Test) |
- |
0 |
|
- |
| 30.2(Needle Flame Test) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 32.1(Radiation Toxicity and Similar Hazards) |
- |
0 |
|
- |
| A.2(Earth continuity test) |
- |
0 |
|
- |
| 22.2(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.3(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.4(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.5(Construction, IS 302-1) |
- |
0 |
|
- |
| Annex C(Ageing test on motors) |
- |
0 |
|
- |
| Annex D(Thermal motor protectors) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 16.1(General) |
- |
0 |
|
- |
| 15.2(Moisture resistance) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- iNCLUDED W.E.F.04.03.2025
EXCLUSION
Cl 32 (Radiation Toxicity and Similar Hazards)
Cl 22.32 (Construction)
CL 24 (Components)
"Domestic Electric Clothes Washing Machines
(For testing charges please refer part 2 standard in LIMS)" |
| 25 |
IS 17550 : Part 2 (2024) |
Household Refrigerating Appliances - Characteristics and Test Methods Part 2 Performance Requirements (First Revision) |
- |
380000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Storage Test) |
- |
80000 |
|
- |
| 7(Cooling Capacity Test) |
- |
50000 |
|
- |
| 8(Freezing Capacity Test) |
- |
50000 |
|
Testing Charges for DC refrigerator :Nil |
| 9("Automatic Ice-Making
Capacity Test") |
- |
50000 |
|
Testing Charges for DC refrigerator :Nil |
| Cl. No.4.6 & Annex A(PULL-DOWN TEST) |
- |
50000 |
|
- |
| Cl. No.4.6(b) & Annex B("Wine Storage
Appliances And
Compartments;
Storage Test") |
- |
50000 |
|
Testing Charges for DC refrigerator :Nil |
| Cl. No.4.6(C) & AnnexC("Temperature Rise
Test ") |
- |
50000 |
|
Testing Charges for DC refrigerator :Nil |
| Cl. No.4.6(d) & Annex D("Water Vapour Condensation
Test ") |
- |
0 |
|
Rs.50,000/- Testing Charges covered in Part 1. |
|
20 Jun, 2028 |
- - |
| 26 |
IS 17550 : Part 1 (2024) |
Household Refrigerating Appliances - Characteristics and Test Methods Part 1 General Requirements (First Revision) |
- |
265000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(MARKING) |
- |
2000 |
|
- |
| 8(MATERIALS, DESIGN, AND MANUFACTURE) |
- |
3000 |
|
Charges for Clause 13 Water Vapour condensation Test : Rs.50000. |
| 9(Testing The Air Tightness Of Door Or Lid Seal(S)) |
- |
5000 |
|
- |
| 10(Testing The Opening Force Of Door(S) Or Lid(S)) |
- |
10000 |
|
- |
| 11(Testing The Durability Of Hinges And Handles Of Door(S) And Lid(S) |
- |
50000 |
|
- |
| 12(Testing The Mechanical Strength Of Shelves And Similar Components) |
- |
10000 |
|
- |
| 14(Ice-Making Test (If Applicable)) |
- |
30000 |
|
- |
| 15(Test For Absence Of Odour And Taste) |
- |
50000 |
|
- |
| 16(Safety Requirements) |
- |
55000 |
|
For Production Routine tests as per clause 20.3 Rs.15000/- |
| 5(MARKING) |
- |
0 |
|
- |
| 8(MATERIALS, DESIGN, AND MANUFACTURE) |
- |
0 |
|
- |
| 9(Testing The Air Tightness Of Door Or Lid Seal(S)) |
- |
0 |
|
- |
| 10(Testing The Opening Force Of Door(S) Or Lid(S)) |
- |
0 |
|
- |
| 11(Testing The Durability Of Hinges And Handles Of Door(S) And Lid(S) |
- |
0 |
|
- |
| 12(Testing The Mechanical Strength Of Shelves And Similar Components) |
- |
0 |
|
- |
| 14(Ice-Making Test (If Applicable)) |
- |
0 |
|
- |
| 15(Test For Absence Of Odour And Taste) |
- |
0 |
|
- |
| 16(Safety Requirements) |
- |
0 |
|
- |
| 5(MARKING) |
- |
0 |
|
- |
| 8(MATERIALS, DESIGN, AND MANUFACTURE) |
- |
0 |
|
- |
| 9(Testing The Air Tightness Of Door Or Lid Seal(S)) |
- |
0 |
|
- |
| 10(Testing The Opening Force Of Door(S) Or Lid(S)) |
- |
0 |
|
- |
| 11(Testing The Durability Of Hinges And Handles Of Door(S) And Lid(S) |
- |
0 |
|
- |
| 12(Testing The Mechanical Strength Of Shelves And Similar Components) |
- |
0 |
|
- |
| 14(Ice-Making Test (If Applicable)) |
- |
0 |
|
- |
| 15(Test For Absence Of Odour And Taste) |
- |
0 |
|
- |
| 16(Safety Requirements) |
- |
0 |
|
- |
| 5(MARKING) |
- |
0 |
|
- |
| 8(MATERIALS, DESIGN, AND MANUFACTURE) |
- |
0 |
|
- |
| 9(Testing The Air Tightness Of Door Or Lid Seal(S)) |
- |
0 |
|
- |
| 10(Testing The Opening Force Of Door(S) Or Lid(S)) |
- |
0 |
|
- |
| 11(Testing The Durability Of Hinges And Handles Of Door(S) And Lid(S) |
- |
0 |
|
- |
| 12(Testing The Mechanical Strength Of Shelves And Similar Components) |
- |
0 |
|
- |
| 14(Ice-Making Test (If Applicable)) |
- |
0 |
|
- |
| 15(Test For Absence Of Odour And Taste) |
- |
0 |
|
- |
| 16(Safety Requirements) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f.03.03.2025 |
| 27 |
IS 11951 (2024) |
PUMPSET FOR DIRECT EVAPORATIVE AIR COOLER — SPECIFICATION (Second Revision) |
- |
49500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.1(Non-Submersible Pumpset) |
- |
1000 |
|
- |
| 5.1.2(Submersible Pumpset) |
- |
1000 |
|
- |
| 6.1, 7.3, 9.1, 9.4.2, Table-1(Discharge Head, m) |
- |
2500 |
|
- |
| 6.1, 7.3, 9.1, 9.4.2,Table-1(Minimum Discharge, l/min) |
- |
2500 |
|
- |
| 6.1, 7.3, 9.1, 9.4.2, Table-1(Type 1 Motor Wattage) |
- |
1000 |
|
- |
| 6.1, 7.3, 9.1, 9.4.2, Table-1(Type 2 Motor Wattage) |
- |
1000 |
|
- |
| 6.1, 7.3, 9.1, 9.4.2, Table-2(Motor Wattage) |
- |
1000 |
|
- |
| 6.1, 7.3, 9.1,9.4.2, Table-2(Minimum Discharge Head, Hd) |
- |
2500 |
|
- |
| 6.1, 7.3, 9.1, 9.4.2,Table-2(Discharge Measurement Height, h) |
- |
2500 |
|
- |
| 6.1, 7.3, 9.1, 9.4.2, Table-2(Minimum, Discharge*) |
- |
2500 |
|
- |
| Cl-8(GENERAL REQUIREMENTS) |
- |
6000 |
|
- |
| 9.2(Tests on motor) |
- |
5000 |
|
- |
| 9.3(Water Requirement) |
- |
1000 |
|
- |
| 9.4.1(Reliability Tests) |
- |
12000 |
|
- |
| 9.4.3(Ingress protection test) |
- |
5000 |
|
- |
| 9.4.6(Dry Run Test) |
- |
2000 |
|
- |
| 9.5(Routine Test) |
- |
5000 |
|
- |
| 9.6(Type Test) |
- |
49500 |
|
- |
| 9.7(Leakage current and electric strength at operating temperature) |
- |
2000 |
|
- |
| 9.7(Moisture resistance) |
- |
4000 |
|
Additional 2000/- charges will be applicable for the test Cl.31 of IS 302-1. |
| 9.7(Leakage current and electric strength) |
- |
2000 |
|
- |
|
20 Jun, 2028 |
- - |
| 28 |
IS 1475 (2024) |
Drinking Water Coolers - Specification (Fourth Revision) |
- |
51000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Classification) |
- |
0 |
|
- |
| 5(Construction) |
- |
5000 |
|
- |
| 6.3(Cooling Capacity Test) |
- |
8000 |
|
- |
| 6.4(Maximum Operating Condition Test) |
- |
5000 |
|
- |
| 6.5(Pull Down Test) |
- |
5000 |
|
- |
| 9(Maximum Power Consumption Test) |
- |
5000 |
|
- |
| 10(Annual Energy Consumption Test) |
- |
8000 |
|
- |
| 11(Storage Capacity Test) |
- |
5000 |
|
- |
| 13(Functional Test) |
- |
2000 |
|
- |
| 14 a)(Protection against electric shock) |
- |
2000 |
|
- |
| 14 b)(High voltage (electric strength) test) |
- |
2000 |
|
- |
| 14 c)(Leakage current tests) |
- |
2000 |
|
- |
| 14 d)(Provision for earthing) |
- |
2000 |
|
- |
| 4(Classification) |
- |
0 |
|
- |
| 5(Construction) |
- |
0 |
|
- |
| 6.3(Cooling Capacity Test) |
- |
0 |
|
- |
| 6.4(Maximum Operating Condition Test) |
- |
0 |
|
- |
| 6.5(Pull Down Test) |
- |
0 |
|
- |
| 9(Maximum Power Consumption Test) |
- |
0 |
|
- |
| 10(Annual Energy Consumption Test) |
- |
0 |
|
- |
| 11(Storage Capacity Test) |
- |
0 |
|
- |
| 13(Functional Test) |
- |
0 |
|
- |
| 14 a)(Protection against electric shock) |
- |
0 |
|
- |
| 14 b)(High voltage (electric strength) test) |
- |
0 |
|
- |
| 14 c)(Leakage current tests) |
- |
0 |
|
- |
| 14 d)(Provision for earthing) |
- |
0 |
|
- |
| 4(Classification) |
- |
0 |
|
- |
| 5(Construction) |
- |
0 |
|
- |
| 6.3(Cooling Capacity Test) |
- |
0 |
|
- |
| 6.4(Maximum Operating Condition Test) |
- |
0 |
|
- |
| 6.5(Pull Down Test) |
- |
0 |
|
- |
| 9(Maximum Power Consumption Test) |
- |
0 |
|
- |
| 10(Annual Energy Consumption Test) |
- |
0 |
|
- |
| 11(Storage Capacity Test) |
- |
0 |
|
- |
| 13(Functional Test) |
- |
0 |
|
- |
| 14 a)(Protection against electric shock) |
- |
0 |
|
- |
| 14 b)(High voltage (electric strength) test) |
- |
0 |
|
- |
| 14 c)(Leakage current tests) |
- |
0 |
|
- |
| 14 d)(Provision for earthing) |
- |
0 |
|
- |
| 4(Classification) |
- |
0 |
|
- |
| 5(Construction) |
- |
0 |
|
- |
| 6.3(Cooling Capacity Test) |
- |
0 |
|
- |
| 6.4(Maximum Operating Condition Test) |
- |
0 |
|
- |
| 6.5(Pull Down Test) |
- |
0 |
|
- |
| 9(Maximum Power Consumption Test) |
- |
0 |
|
- |
| 10(Annual Energy Consumption Test) |
- |
0 |
|
- |
| 11(Storage Capacity Test) |
- |
0 |
|
- |
| 13(Functional Test) |
- |
0 |
|
- |
| 14 a)(Protection against electric shock) |
- |
0 |
|
- |
| 14 b)(High voltage (electric strength) test) |
- |
0 |
|
- |
| 14 c)(Leakage current tests) |
- |
0 |
|
- |
| 14 d)(Provision for earthing) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f 27.03.2025 |
| 29 |
IS 302 : Part 2 : Sec 21 (2024) |
Household and Similar Electrical Appliances�Safety Part 2 Particular Requirements Section 21 Storage Water Heaters |
- |
125000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General requirement) |
- |
0 |
|
- |
| 5(General conditions for the tests) |
- |
0 |
|
- |
| 6(Classification) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
1000 |
|
- |
| 8(Protection against access to live parts) |
- |
2000 |
|
- |
| 10(Power input and current) |
- |
5000 |
|
- |
| 11(Heating) |
- |
6000 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
3000 |
|
- |
| 14(Transient overvoltages) |
- |
2000 |
|
- |
| 15(Moisture resistance) |
- |
3000 |
|
- |
| 16(Leakage current and electric strength) |
- |
3000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
2000 |
|
- |
| 19(Abnormal operation) |
- |
10000 |
|
Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. The testing charges for EMI/EMC testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be applicable |
| 20(Stability and mechanical hazards) |
- |
1000 |
|
- |
| 21(Mechanical strength) |
- |
5000 |
|
- |
| 22(Construction) |
- |
5000 |
|
- |
| 23(Internal wiring) |
- |
1000 |
|
- |
| 24(Components) |
- |
3000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
3000 |
|
- |
| 26(Terminals for external conductors) |
- |
2000 |
|
- |
| 27(Provision for earthing) |
- |
2000 |
|
- |
| 28(Screws and connections) |
- |
1000 |
|
- |
| 29(Clearances, creepage distances and solid insulation) |
- |
2000 |
|
- |
| 30(Resistance to heat and fire) |
- |
4000 |
|
- |
| 31(Resistance to rusting) |
- |
1000 |
|
- |
| 32(Radiation, toxicity and similar hazards) |
- |
2000 |
|
Charges applicable excluding the test of Cl.12 (Charging of metal-ion batteries). In case of Battery operated water heater used then additional charges and testing time will be applicable accordingly. |
| A.101(Pressure test) |
- |
1000 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
5000 |
|
if applicable |
| 19.11.4.2(Radiated fields) |
- |
20000 |
|
if applicable |
| 19.11.4.3(Fast transient bursts) |
- |
5000 |
|
if applicable |
| 19.11.4.4(Surge immunity test) |
- |
5000 |
|
if applicable |
| 19.11.4.5(Immunity to conducted discharges) |
- |
10000 |
|
if applicable |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
5000 |
|
if applicable |
| 19.11.4.7(Harmonics) |
- |
5000 |
|
if applicable |
| 9(Starting of motor-operated appliances) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 4(General requirement) |
- |
0 |
|
- |
| 5(General conditions for the tests) |
- |
0 |
|
- |
| 6(Classification) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8(Protection against access to live parts) |
- |
0 |
|
- |
| 10(Power input and current) |
- |
0 |
|
- |
| 11(Heating) |
- |
0 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
| 14(Transient overvoltages) |
- |
0 |
|
- |
| 15(Moisture resistance) |
- |
0 |
|
- |
| 16(Leakage current and electric strength) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 19(Abnormal operation) |
- |
0 |
|
- |
| 20(Stability and mechanical hazards) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
0 |
|
- |
| 26(Terminals for external conductors) |
- |
0 |
|
- |
| 27(Provision for earthing) |
- |
0 |
|
- |
| 28(Screws and connections) |
- |
0 |
|
- |
| 29(Clearances, creepage distances and solid insulation) |
- |
0 |
|
- |
| 30(Resistance to heat and fire) |
- |
0 |
|
- |
| 31(Resistance to rusting) |
- |
0 |
|
- |
| 32(Radiation, toxicity and similar hazards) |
- |
0 |
|
- |
| A.101(Pressure test) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 9(Starting of motor-operated appliances) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f 12.11.2024
Exclusion
32 (Radiation, toxicity and similar hazards) |
| 30 |
IS 2993 : Part 2 (2024) |
a.c. Motor Capacitors Part 2 Motor Start Capacitors ( Third Revision ) |
- |
358250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.1.1(General) |
- |
4000 |
|
- |
| 5.1.7(Voltage test between the terminals) |
- |
9000 |
|
- |
| 5.1.8(Voltage test between terminals and case) |
- |
9000 |
|
- |
| 5.1.9(Capacitance measurement) |
- |
31500 |
|
capacitance measurement charge is 13500 & Tangent of loss angle charge is 18000 |
| 5.1.10(Check of dimensions) |
- |
4000 |
|
- |
| 5.1.11.1(Robustness of terminations) |
- |
36000 |
|
- |
| 5.1.11.2(Soldering) |
- |
5000 |
|
- |
| 5.1.11.3(Vibration) |
- |
21500 |
|
Vibration charge is : 20000 & Fixing bolt charge is: 1500 |
| 5.1.12(Sealing test) |
- |
9000 |
|
- |
| 5.1.13(Endurance test) |
- |
95000 |
|
- |
| 5.1.14(Damp heat test) |
- |
66000 |
|
- |
| 5.1.15(Self-healing test) |
- |
9000 |
|
- |
| 5.1.16(Destruction test) |
- |
44250 |
|
- |
| 5.1.17.1(Ball-pressure test) |
- |
3000 |
|
- |
| 5.1.17.2(Glow-wire test) |
- |
3000 |
|
- |
| 5.1.17.3(Tracking test) |
- |
5000 |
|
- |
| 5.2(Overloads) |
- |
0 |
|
- |
| 5.3.1(Creepage distances and clearances) |
- |
0 |
|
- |
| 5.3.2(Terminals and connecting cables) |
- |
0 |
|
- |
| 5.3.3(Earth connections) |
- |
0 |
|
- |
| 5.3.4(Discharge devices) |
- |
0 |
|
- |
| 5.3.5(Pollution) |
- |
0 |
|
- |
| 5.4(Marking) |
- |
4000 |
|
- |
| 6.1.6(Voltage test between the terminals) |
- |
9000 |
|
For Electrolytic motor start capacitors |
| 6.1.7(Voltage test between terminals and case) |
- |
9000 |
|
For Electrolytic motor start capacitors |
| 6.1.8(Capacitance and power factor measurement) |
- |
15000 |
|
For Electrolytic motor start capacitors |
| 6.1.9(Check of dimensions) |
- |
4000 |
|
For Electrolytic motor start capacitors |
| 6.1.10.1(Robustness of terminations) |
- |
36000 |
|
For Electrolytic motor start capacitors |
| 6.1.10.2(Soldering) |
- |
5000 |
|
For Electrolytic motor start capacitors |
| 6.1.10.3(Vibration) |
- |
20000 |
|
For Electrolytic motor start capacitors |
| 6.1.10.4(Fixing bolt or stud (if fitted)) |
- |
1500 |
|
- |
| 6.1.10.5(Rapid change of temperature) |
- |
10000 |
|
For Electrolytic motor start capacitors |
| 6.1.11(Sealing test) |
- |
9000 |
|
For Electrolytic motor start capacitors |
| 6.1.12(Endurance test) |
- |
95000 |
|
For Electrolytic motor start capacitors |
| 6.1.13(Damp heat test) |
- |
66000 |
|
For Electrolytic motor start capacitors |
| 6.1.14(Pressure relief test) |
- |
5000 |
|
For Electrolytic motor start capacitors |
| 6.1.15.1(Ball-pressure test) |
- |
3000 |
|
For Electrolytic motor start capacitors |
| 6.1.15.2(Glow-wire test) |
- |
3000 |
|
For Electrolytic motor start capacitors |
| 6.1.15.3(Tracking test) |
- |
5000 |
|
For Electrolytic motor start capacitors |
| 6.2(Overloads) |
- |
0 |
|
- |
| 6.3.1(Creepage distances and clearances) |
- |
0 |
|
- |
| 6.3.2(Terminals and connecting cables) |
- |
0 |
|
- |
| 6.3.3(Earth connections) |
- |
0 |
|
- |
| 6.3.4(Discharge devices) |
- |
0 |
|
- |
| 6.3.5(Pollution) |
- |
0 |
|
- |
| 6.4(Marking) |
- |
4000 |
|
For Electrolytic motor start capacitors |
| 7.2.1(Measurement of working voltage) |
- |
0 |
|
- |
| 7.2.2(Influence of capacitance) |
- |
0 |
|
- |
| 7.3(Checking capacitor temperature) |
- |
0 |
|
- |
| 7.4(Checking transients) |
- |
0 |
|
- |
| 7.5(Storage of electrolytic capacitors) |
- |
0 |
|
- |
| Annex A(Test voltage) |
- |
0 |
|
- |
| 5.1.10(Check of dimensions) |
- |
0 |
|
- |
| 6.1.10.4(Fixing bolt or stud (if fitted)) |
- |
0 |
|
- |
| 5.1.1.1(General) |
- |
- |
|
- |
| 5.1.7(Voltage test between the terminals) |
- |
- |
|
- |
| 5.1.8(Voltage test between terminals and case) |
- |
- |
|
- |
| 5.1.9(Capacitance measurement) |
- |
- |
|
- |
| 5.1.10(Check of dimensions) |
- |
- |
|
- |
| 5.1.11.1(Robustness of terminations) |
- |
- |
|
- |
| 5.1.11.2(Soldering) |
- |
- |
|
- |
| 5.1.11.3(Vibration) |
- |
- |
|
- |
| 5.1.12(Sealing test) |
- |
- |
|
- |
| 5.1.13(Endurance test) |
- |
- |
|
- |
| 5.1.14(Damp heat test) |
- |
- |
|
- |
| 5.1.15(Self-healing test) |
- |
- |
|
- |
| 5.1.16(Destruction test) |
- |
- |
|
- |
| 5.1.17.1(Ball-pressure test) |
- |
- |
|
- |
| 5.1.17.2(Glow-wire test) |
- |
- |
|
- |
| 5.1.17.3(Tracking test) |
- |
- |
|
- |
| 5.2(Overloads) |
- |
- |
|
- |
| 5.3.1(Creepage distances and clearances) |
- |
- |
|
- |
| 5.3.2(Terminals and connecting cables) |
- |
- |
|
- |
| 5.3.3(Earth connections) |
- |
- |
|
- |
| 5.3.4(Discharge devices) |
- |
- |
|
- |
| 5.3.5(Pollution) |
- |
- |
|
- |
| 5.4(Marking) |
- |
- |
|
- |
| 6.1.6(Voltage test between the terminals) |
- |
- |
|
- |
| 6.1.7(Voltage test between terminals and case) |
- |
- |
|
- |
| 6.1.8(Capacitance and power factor measurement) |
- |
- |
|
- |
| 6.1.9(Check of dimensions) |
- |
- |
|
- |
| 6.1.10.1(Robustness of terminations) |
- |
- |
|
- |
| 6.1.10.2(Soldering) |
- |
- |
|
- |
| 6.1.10.3(Vibration) |
- |
- |
|
- |
| 6.1.10.4(Fixing bolt or stud (if fitted)) |
- |
- |
|
- |
| 6.1.10.5(Rapid change of temperature) |
- |
- |
|
- |
| 6.1.11(Sealing test) |
- |
- |
|
- |
| 6.1.12(Endurance test) |
- |
- |
|
- |
| 6.1.13(Damp heat test) |
- |
- |
|
- |
| 6.1.14(Pressure relief test) |
- |
- |
|
- |
| 6.1.15.1(Ball-pressure test) |
- |
- |
|
- |
| 6.1.15.2(Glow-wire test) |
- |
- |
|
- |
| 6.1.15.3(Tracking test) |
- |
- |
|
- |
| 6.2(Overloads) |
- |
- |
|
- |
| 6.3.1(Creepage distances and clearances) |
- |
- |
|
- |
| 6.3.2(Terminals and connecting cables) |
- |
- |
|
- |
| 6.3.3(Earth connections) |
- |
- |
|
- |
| 6.3.4(Discharge devices) |
- |
- |
|
- |
| 6.3.5(Pollution) |
- |
- |
|
- |
| 6.4(Marking) |
- |
- |
|
- |
| 7.2.1(Measurement of working voltage) |
- |
- |
|
- |
| 7.2.2(Influence of capacitance) |
- |
- |
|
- |
| 7.3(Checking capacitor temperature) |
- |
- |
|
- |
| 7.4(Checking transients) |
- |
- |
|
- |
| 7.5(Storage of electrolytic capacitors) |
- |
- |
|
- |
| Annex A(Test voltage) |
- |
- |
|
- |
| 5.1.10(Check of dimensions) |
- |
- |
|
- |
| 6.1.10.4(Fixing bolt or stud (if fitted)) |
- |
- |
|
- |
|
20 Jun, 2028 |
- Included w.e.f 05.11.2024 |