211 |
IS 7092 : Part 2 (1987) |
Specification for aluminium alloy tube for irrigation purposes: Part 2 extruded tube (Second Revision) |
- |
-
|
Rs 11230/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6.2 (Ultimate Tensile Strength- IS 2657) |
- |
|
|
|
Cl. 6.4 (Hydrostatic Pressure Test-Cl. 6.4) |
- |
|
|
|
Cl.7.1, Table 2 (Outside Diameter-) |
- |
|
|
|
Cl.7.1, Table 2 (Wall Thickness) |
- |
|
|
|
Cl. 7.2 (Length) |
- |
|
|
|
Cl.4 (Workmanship & Finish) |
- |
|
|
|
|
Partial
|
|
- |
Excluding proof stress and Facility for chemical testing is not available |
212 |
IS 6218 (2008) |
Bicycle - Mudguards - Specification (First Revision) |
- |
-
|
- View breakup
Rs. 5400/- and material testing charges as per relevant referred ISs
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause-3 (Carbon) |
- |
|
|
|
Clause-3 (Sulphur) |
- |
|
|
|
Clause-3 (Phosphorus) |
- |
|
|
|
Clause-3 (Silicon) |
- |
|
|
|
Clause-3 (Nitrogen) |
- |
|
|
|
Cl 5.3(Mech) (The wraping of the mudguard shall lie within the limits ) |
- |
|
|
|
Cl 5.1(Mech) (The paint shall not soften,peel off or show any change in colour after the test.) |
- |
|
|
|
Cl 4.3(Mech) (The painted part shall be free from wrinkles, blisters,unevenness,scratch marks and other injurious defects.) |
- |
|
|
|
Cl 4.2(Mech) (The mudguard shall be free from manufacturing defects and shall be chemically phosphated and and stove enamelled , spray painted or otherwise finished to give a glossy finish .) |
- |
|
|
|
Cl 4.1(Mech) (Thickness of steel strip) |
- |
|
|
|
Cl 4.1(Mech) (Depth of mudguard) |
- |
|
|
|
Cl 4.1(Mech) (Width of mudguard ) |
- |
|
|
|
Cl 4(Mech) (Manufacture ,Workmanship ,& Finish ) |
- |
|
|
|
|
Partial
|
|
- |
Test facility for all test available but Separate sample of steel strip may be provided for thickness. |
213 |
IS 455 (2015) |
Portland slag cement - Specification |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7 Table 1 iv c (Compretsive Strenqth 672 ± 4 hr
IS 4031(Part 6)) |
- |
|
|
|
7 Table 1 iv b (Compretsive Strenqth 168 ± 2 hr
IS 4031(Part 6)) |
- |
|
|
|
7 Table 1 iv a (Compretsive Strenqth .72 ± 1 hr
IS 4031(Part 6)) |
- |
|
|
|
7 Table 1 iii b (Setting Time ( by Vicat Apparatus ), Final
IS 4031(Part 5)) |
- |
|
|
|
7 Table 1 iii a (Setting Time ( by Vicat Apparatus ),Initial
IS 4031(Part 5)) |
- |
|
|
|
7 Table 1 ii b (Soundness, Autoclave expansion
IS 4031(Part 3) ) |
- |
|
|
|
7 Table 1 ii a (Soundness, Le-Chate1ier expansion
IS 4031(Part 3) ) |
- |
|
|
|
7 Table 1 i (Fineness
IS 4031(Part 2)) |
- |
|
|
|
6 - Table - 1 vii ( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 vi (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 v (Loss on ignition - Cl 6.2 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 iii (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 6.11 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 ii (Magnesia - Cl 6.8 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 i (Insoluble residue - Cl 6.9 of IS 4032:1985) |
- |
|
|
|
|
Partial
|
|
- |
Except Transverse Strength Test, sulphide Sulphur |
214 |
IS 6003 (2010) |
Indented Wire For--Prestressed Concrete ” |
- |
-
|
Rs.4110/- excl. relaxation test View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5.1 (Diameter) |
- |
|
|
|
Cl 6.1.2 (Weight) |
- |
|
|
|
Cl 7.1 (Tensile Test On UTM) |
- |
|
|
|
Cl 7.3 (Reverse Bend Test) |
- |
|
|
|
4.1.1 (Phosphorus %) |
- |
|
|
|
4.1.1 (Sulphur %) |
- |
|
|
|
4.1.1 (Phosphorus %) |
- |
|
|
|
4.1.1 (Sulphur %) |
- |
|
|
|
4.1.1 (Phosphorus %) |
- |
|
|
|
4.1.1 (Sulphur %) |
- |
|
|
|
|
Partial
|
|
- |
Test Facility Complete for Chemical Except Stress relaxation test , Proof stress |
215 |
IS 1029 (1970) |
Specification for hot-rolled steel strip (Baling) (First Revision) |
- |
-
|
Rs.750/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.2 (Tensile Test-1608:Part 1) |
- |
|
|
|
5.2 (Tensile Strength, Mpa) |
- |
|
|
|
5.2 (Elongation, %) |
- |
|
|
|
5.3 (Bend Test-1599) |
- |
|
|
|
8.2 (Width) |
- |
|
|
|
8.2 (Thickness) |
- |
|
|
|
7.1 (Freedom from defects) |
- |
|
|
|
9.1 (Finishing & Packing) |
- |
|
|
|
|
Complete
|
|
- |
Test Facilty complete |
216 |
IS 9890 (1981) |
Specification for general purpose ball valves |
- |
-
|
Rs 4520/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5 (End connections) |
- |
|
|
|
|
Partial
|
|
- |
Facility for chemical testing is not available |
217 |
IS 4398 (1994) |
Carbon - Chromium steel for the manufacture of balls, rollers and bearing races - Specification (Second Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8 ( Hardness-IS 1500: Pt 1) |
- |
|
|
|
Cl. 5.1 & Table 1 (Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl. 5.1 & Table 1 (Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl. 5.1 & Table 1 (Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl. 5.1 & Table 1 (Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl. 5.1 & Table 1 (Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
|
Partial
|
|
- |
Microstructure, Inclusion, Decarburization, Cr, Ni, Mo, Cu, V and Ti. |
218 |
IS 10086 (1982) |
Specificaton for moulds for use in tests of cement and concrete |
- |
-
|
Rs 14700/- and Material testing charges as per relevan View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (Dimension and tolerances of cylindrical moulds Table 3) |
- |
|
|
|
Cl 5.1 (Construction) |
- |
|
|
|
Cl 5.3 (Arangement for fastening / Clamping) |
- |
|
|
|
4.1 (Dimension and Tolerances of Cube Moulds Table 2) |
- |
|
|
|
4.1 (Dimension and Tolerances of Cube Moulds Table 2) |
- |
|
|
|
4.1 (Dimension and Tolerances of Cube Moulds Table 2) |
- |
|
|
|
4.1 (Dimension and Tolerances of Cube Moulds Table 2) |
- |
|
|
|
4.1 (Dimension and Tolerances of Cube Moulds Table 2) |
- |
|
|
|
4.1 (Dimension and Tolerances of Cube Moulds Table 2) |
- |
|
|
|
5.1.1 (Construction) |
- |
|
|
|
4.1 (Dimension and Tolerances of Cube Moulds Table 2) |
- |
|
|
|
5.1.2 (Construction) |
- |
|
|
|
5.2.1 (Cube Mould) |
- |
|
|
|
5.2.2 (Cylindrical Mould (Fig.3)) |
- |
|
|
|
5.2.3 (Beam Mould (Fig. 4)) |
- |
|
|
|
5.2.4 (Bar Mould ( Fig. 5, 6, 7 & 8 )) |
- |
|
|
|
4.1 (Dimension and Tolerances of Cube Moulds Table 2) |
- |
|
|
|
4.1 (Dimension and Tolerances of Cube Moulds Table 2) |
- |
|
|
|
4.1 (Dimension and Tolerances of Cube Moulds Table 2) |
- |
|
|
|
4.1 (Dimension and tolerances of cylindrical moulds Table 3) |
- |
|
|
|
4.1 (Dimension and tolerances of beam moulds Table 4) |
- |
|
|
|
4.1 (Dimension and Tolerances of bar moulds Table 5) |
- |
|
|
|
2.1 (Types) |
- |
|
|
|
2.1 (Types) |
- |
|
|
|
2.1 (Types) |
- |
|
|
|
2.1 (Types) |
- |
|
|
|
2.1 (Types) |
- |
|
|
|
4.1 (Dimension and tolerances of cylindrical moulds Table 3) |
- |
|
|
|
|
Partial
|
|
- |
Standard has been revised as IS 10086 : 2021 Except Shore Hardness, Dimension stability , Drop test , Facility for chemical testing is not available |
219 |
IS 2052 (2009) |
Compounded feeds for cattle - Specification (Fourth Revision) |
- |
-
|
Rs. 9210/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.3 - Table 1 - i (Moisture - Cl 4 of IS 7874 (Part 1)) |
- |
|
|
|
4.3 - Table 1 - ii (Crude protein (N x 6.25) - Cl 5 of IS 7874 (Part 1)) |
- |
|
|
|
4.3 - Table 1 - iii (Crude fat - Cl 7 of IS 7874 (Part 1)) |
- |
|
|
|
4.3 - Table 1 - iv (Crude fibre - Cl 8 of IS 7874 (Part 1)) |
- |
|
|
|
4.3 - Table 1 - v (Acid insoluble ash - Cl 10 of IS 7874 (Part 1)) |
- |
|
|
|
4.3 - Table 2 - i (Salt (as NaCl) - Cl 4 of IS 7874 (Part 2)) |
- |
|
|
|
4.3 - Table 2 - ii (Calcium (as Ca) - IS 13433 (Part 1 / Part 2)) |
- |
|
|
|
4.3 - Table 2 - iii (Total Phosphorus - IS 14828) |
- |
|
|
|
4.1 (Description - The feed shall be free from harmful constituents, metallic pieces and adulterants. The feed shall also be free from fungal growth and insect infestation. And from fermented . musty, rancid or any other objectionable odour) |
- |
|
|
|
|
Partial
|
|
- |
Except Urea, Vitamin A,D, E, Aflatoxin and Cadmium, available phosphorous |
220 |
IS 15911 (2010) |
Structural steel (Ordinary Quality) - Specification |
E 165 ,E 170 , E 215 |
-
|
Rs 6750/- For elements other than Table-1: Rs 1004/- pe View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Table-1, 5.1, 8.1 & 8.2 (Carbon: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
Table-1, 5.1, 8.1 & 8.2 (Sulphur: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
Table-1, 5.1, 8.1 & 8.2 (Phosphorous: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
Table-1, 5.1, 8.1 & 8.2 (Manganese: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
Table-1, 5.1, 8.1 & 8.2 (Silicon: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
Table-1, 5.1, 8.1 & 8.2 (Phosphorous: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
Table-1, 5.1, 8.1 & 8.2 (Manganese: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
Table-1, 5.1, 8.1 & 8.2 (Nitrogen: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
|
Partial
|
|
- |
Except Microalloys , Al,Cu |
221 |
IS 8783 : Part 4 : Sec 3 (1995) |
Winding wires for submersible motors - Specification: Part 4 specification for individual wires: Sec 3 polyester and polypropylene insulated winding wires (First Revision) |
- |
-
|
Rs.8700/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1 (The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
|
|
|
6.1 (The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
|
|
|
6.1 (a) Reference to this Indian Standard;) |
- |
|
|
|
6.1 (c) Size of conductor / maximum overall diameter,) |
- |
|
|
|
6.1 (d) Length of conductor on spool / reel /coil;) |
- |
|
|
|
6.1 (e) Number of lengths onspool / reel / coil (if more than one);) |
- |
|
|
|
6.1 (f) Country of Manufacturer) |
- |
|
|
|
6.1 (g) Year of Manufacture.) |
- |
|
|
|
6.2 (BIS Certification Mark) |
- |
|
|
|
4 (i) Material) |
- |
|
|
|
5 (ii) Diameter [mm] Seperate wire:) |
- |
|
|
|
5 (ii) Diameter [mm] Wire taken from cable:) |
- |
|
|
|
5 (iii) Annealing test [Percentage] on Seperate wire:) |
- |
|
|
|
5 (iii) Annealing test [Percentage] on Wire taken from cable:) |
- |
|
|
|
5 (d) Resistance test [Ohm/km corrected to 20°c) |
- |
|
|
|
4.1, table 1 & 2 (a) Thickness of Polyster (mm)) |
- |
|
|
|
4.1, table 1 & 3 (b) Thickness of Polypropylene (mm)) |
- |
|
|
|
4.1, table 1 & 4 (c) Total thickness of Insulation(mm)) |
- |
|
|
|
4.2 (Application of insulation) |
- |
|
|
|
4.3 (Colour of Insuation) |
- |
|
|
|
4.4 (Overall diameter (mm)) |
- |
|
|
|
4 (Before ageing Tensile strength [N/mm²]) |
- |
|
|
|
4 (Before ageing Elongation at break [Percentage]) |
- |
|
|
|
4 (After ageing Tensile strength [N/mm²]) |
- |
|
|
|
4 (Variation on tensile strangth [Percentage]) |
- |
|
|
|
4 (After ageing Elongation at break [Percentage]) |
- |
|
|
|
4 (Variation on elongation at break [Percentage]) |
- |
|
|
|
4 (Shrinkage test [Percentage]) |
- |
|
|
|
4 (After Shrinkage Cracks found.) |
- |
|
|
|
4.1 (Water absorption test [Gravimetric] [mg/cm²]) |
- |
|
|
|
4.1 (Hot Deformation test [depth of indentation) [Percentage]) |
- |
|
|
|
4.1 (Heat Shock Test - No cracks found) |
- |
|
|
|
4.1 (Insulation Resistance test [ohm-cm] At 27 ºC) |
- |
|
|
|
4.1 ([Insulation Resistance test [ohm-cm] At 90 ºC) |
- |
|
|
|
4.5 (High Voltage test [Water Immersion test] 3 KV for 1 Minute) |
- |
|
|
|
5 (The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
|
|
|
6 (The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
|
|
|
6 (a) Reference to this Indian Standard;) |
- |
|
|
|
6 (c) Size of conductor / maximum overall diameter,) |
- |
|
|
|
6 (d) Length of conductor on spool / reel /coil;) |
- |
|
|
|
6 (e) Number of lengths onspool / reel / coil (if more than one);) |
- |
|
|
|
6 (f) Country of Manufacturer Marking) |
- |
|
|
|
6 (g) Year of Manufacture.) |
- |
|
|
|
6.2 (BIS Certification Mark) |
- |
|
|
|
4 (i) Material) |
- |
|
|
|
4 (ii) Diameter [mm] Seperate wire:) |
- |
|
|
|
4 (ii) Diameter [mm] Wire taken from cable) |
- |
|
|
|
4 (iii) Annealing test [Percentage] on Seperate wire:) |
- |
|
|
|
4 ([iii) Annealing test [Percentage] on Wire taken from cable:) |
- |
|
|
|
4 (d) Resistance test [Ohm/km corrected to 20°c]) |
- |
|
|
|
4 (a) Thickness of Polyster (mm)) |
- |
|
|
|
4 (b) Thickness of Polypropylene (mm)) |
- |
|
|
|
4 (c) Total thickness of Insulation(mm)) |
- |
|
|
|
4.2 (Application of insulation) |
- |
|
|
|
4 (Colour of Insuation) |
- |
|
|
|
4 (Overall diameter (mm)) |
- |
|
|
|
4 (Before ageing Tensile strength [N/mm²]) |
- |
|
|
|
4 (Before ageing Elongation at break [Percentage]) |
- |
|
|
|
4 (After ageing Tensile strength [N/mm²]) |
- |
|
|
|
4 (Variation on tensile strangth [Percentage]) |
- |
|
|
|
4 (After ageing Elongation at break [Percentage]) |
- |
|
|
|
4 (Variation on elongation at break [Percentage]) |
- |
|
|
|
4 (Shrinkage test [Percentage]) |
- |
|
|
|
4 (After Shrinkage Cracks found.) |
- |
|
|
|
4 (Water absorption test [Gravimetric] [mg/cm²]) |
- |
|
|
|
4 (Hot Deformation test [depth of indentation) [Percentage]) |
- |
|
|
|
4 (Heat Shock Test - No cracks found Physical) |
- |
|
|
|
4 (High Voltage test [Water Immersion test] 3 KV for 1 Minute) |
- |
|
|
|
4 (Insulation Resistance test [ohm-cm] At 27 ºC) |
- |
|
|
|
4 (Insulation Resistance test [ohm-cm] At 90 ºC) |
- |
|
|
|
|
Complete
|
|
- |
Test facility is complete |
222 |
IS 9295 (1983) |
Specification for steel tubes for idlers for belt conveyors (First Revision) |
- |
-
|
Rs 5100/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1 (Sulphur- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
7.1 (Phosphorous- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
8.1.1 Table 1 (Tensile Strength- IS 1608(1)) |
- |
|
|
|
8.1.1 Table 1 (Yield Strength- IS 1608) |
- |
|
|
|
8.1.1 Table 1 (Elongation Percent- IS 1608) |
- |
|
|
|
8.2 (Drift Expansion Test- IS 2335) |
- |
|
|
|
8.3 (Flattening Test- IS 2328) |
- |
|
|
|
9.1 Table 2 (Outside Diameter) |
- |
|
|
|
9.1 Table 2 (Thickness) |
- |
|
|
|
9.1 Table 2 (Mass) |
- |
|
|
|
10 (Hardness) |
- |
|
|
|
13.1.1 (Ovality) |
- |
|
|
|
13.1.2 (Eccentricity) |
- |
|
|
|
15.1 (Straightness) |
- |
|
|
|
16.1 (Length) |
- |
|
|
|
|
Complete
|
|
- |
Test facility is complete |
223 |
IS 2507 (1975) |
Specification for cold - rolled steel strips for springs (First Revision) |
- |
-
|
Rs .6000/- Gr 1 to Gr 9 View breakup
Rs.3900/- for Gr.10, Rs.4500/- for Gr.11
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 0.2, 4.1, 6.1, 6.2 & Table1 (Carbon- Appropriate parts of IS 228.) |
- |
|
|
|
Cl. 0.2, 4.1, 6.1, 6.2 & Table1 (Sulphur- Appropriate parts of IS 228.) |
- |
|
|
|
Cl. 0.2, 4.1, 6.1, 6.2 & Table1 (Silicon- Appropriate parts of IS 228.) |
- |
|
|
|
Cl. 0.2, 4.1, 6.1, 6.2 & Table1 (Manganese- Appropriate parts of IS 228.) |
- |
|
|
|
Cl. 0.2, 4.1, 6.1, 6.2 & Table1 (Phosphorus- Appropriate parts of IS 228.) |
- |
|
|
|
7 (Rolling Tolerances) |
- |
|
|
|
10 (Physical properties(optional)) |
- |
|
|
|
5 (FREEDOM FROM DEFECTS) |
- |
|
|
|
|
Partial
|
|
- |
Decarburization, Grade 10(Except Cr and V), microalloys |
224 |
IS 8931 (1993) |
copper alloy fancy single taps, combination tap assembly and stop valves for water services |
- |
-
|
Rs 3600/ View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 6.6 (Screw Threads) |
- |
|
|
|
Cl 6.7 (Waterway) |
- |
|
|
|
Cl 6.9 (Body Seat) |
- |
|
|
|
Cl 7.3 (Bonnet Assembly) |
- |
|
|
|
Cl 8 (Finish) |
- |
|
|
|
|
Partial
|
|
- |
Standard has been revised as IS 8931 : 2021 Except Performance test, water efficiency rating and Endurance test, Facility for chemical testing is not available |
225 |
IS 2029 (1998) |
Ring wrenches (Spanners) - Specification (Fourth Revision) |
- |
-
|
Rs.3700/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3, Table-1 (Dimensions- s1) |
- |
|
|
|
3, Table-1 (Dimensions- s2) |
- |
|
|
|
3, Table-1 (Dimensions- a) |
- |
|
|
|
3, Table-1 (Dimensions- b1) |
- |
|
|
|
3, Table-1 (Dimensions- b2) |
- |
|
|
|
3, Table-1 (Dimensions- L) |
- |
|
|
|
6 (Workmanship and Finish) |
- |
|
|
|
7 (Designation) |
- |
|
|
|
Cl.4 (CARBON) |
- |
|
|
|
Cl.4 (SULPHUR) |
- |
|
|
|
Cl.4 (PHOSPHURS) |
- |
|
|
|
Cl.4 (MANGANESE) |
- |
|
|
|
Cl.4 (SILICON) |
- |
|
|
|
|
Partial
|
|
- |
Excluding Torque test, Micro alloying elements |
226 |
IS 2721 (2003) |
Galvanized steel chain link fence fabric - Specification (Second Revision) |
- |
-
|
- View breakup
Rs.5950/- (for wire below 5 mm Dia), Rs.6910/- (for wires above 5 mm Dia) and Material testing charges as per relevant referred Iss
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.5 (Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl.5 (Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl.5 (Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl.5 (Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl.5 (Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl.8 (Chain link fence fabric(Mass of zinc coating)- IS 6745) |
- |
|
|
|
Cl.8 (Chain link fence fabric (Uniformity of Zinc coating)-IS 2633) |
- |
|
|
|
Cl.9.2 (Mesh wire (Mass of zinc coating)- IS 6745) |
- |
|
|
|
Cl.9.2 (Mesh Wire (Uniformity of Zinc coating)-IS 2633) |
- |
|
|
|
Cl.6.1, 6.2, Table 1 (Mesh Size) |
- |
|
|
|
Cl.6.3, Table 1 (Width of the fabric) |
- |
|
|
|
Cl.6.3, Table 1 (Length of the fabric) |
- |
|
|
|
Cl.6.1, 6.2, Table 1 (Nominal Dia of Mesh wire) |
- |
|
|
|
Cl. 7.2 and Table 1 (Line Wire (Diameter)) |
- |
|
|
|
Cl. 7.2 and Table 1 (Line Wire (Number of wires)) |
- |
|
|
|
Cl.9.1.1 (Tensile test of mesh and line wires- IS 1608) |
- |
|
|
|
Cl.9.1.2 (Wrapping test of mesh and line wires-IS 1755) |
- |
|
|
|
Cl.9.1.3 (Twist test of mesh and line wires-IS 1717) |
- |
|
|
|
Cl.9.1.4 (Bend test of mesh and line wires- IS 1608) |
- |
|
|
|
|
Complete
|
|
- |
Test facility is complete |
227 |
IS 4223 (1975) |
Steel Wire For Umbrella Ribs |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8,9 (Sizes and Tolerances - IS 4223) |
- |
|
|
|
10.1, Table 1 (Mechanical ptoperties - IS 1608(Pt -1)) |
- |
|
|
|
10.2 (Torsion Test - IS 1717) |
- |
|
|
|
7 (Freedom rom defects , IS 4223) |
- |
|
|
|
10.3 (Reverse Bend Test--IS 1716) |
- |
|
|
|
Cl 6.1 (Sulphur- Appropriate parts of IS 228.) |
- |
|
|
|
Cl 6.1 (Phosphorus- Appropriate parts of IS 228.) |
- |
|
|
|
Cl 6.1 (Sulphur- Appropriate parts of IS 228.) |
- |
|
|
|
Cl 6.1 (Phosphorus- Appropriate parts of IS 228.) |
- |
|
|
|
|
Complete
|
|
- |
Test facility is complete |
228 |
IS 2028 (2004) |
Open jaw wrenches (Spanners) - Specification (Fijih Revision) |
- |
-
|
Rs.3700/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1 (Dimensions- a) |
- |
|
|
|
3.1 (Dimensions- b) |
- |
|
|
|
3.1 (Dimensions- l) |
- |
|
|
|
3.2, 3.3, 3.4 (Dimensions- a) |
- |
|
|
|
3.2, 3.3, 3.4 (Dimensions- b1) |
- |
|
|
|
3.2, 3.3, 3.4 (Dimensions- b2) |
- |
|
|
|
3.2, 3.3, 3.4 (Dimensions- l) |
- |
|
|
|
3.2, 3.3, 3.4 (Dimensions- b2) |
- |
|
|
|
6 (Workmanship And Finish) |
- |
|
|
|
|
Partial
|
|
- |
Excluding Torque test, Micro alloying elements |
229 |
IS 9523 (2000) |
Ductile iron fittings for pressure pipes for water, gas and sewage - Specification (First Revision) |
- |
-
|
Rs.7245.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5 (Thickness) |
- |
|
|
|
Cl 6 & Table 4,5,6&7 (Design & Tolerance) |
- |
|
|
|
Cl 9 (Tensile Test & Hardness Test) |
- |
|
|
|
Cl 10 (Hydrostatic Test) |
- |
|
|
|
Cl 11 (Nominal Diameter, Ovality, Dimensions, No. Of Holes & Bolt Sizes) |
- |
|
|
|
Cl 13 (Coating) |
- |
|
|
|
|
Partial
|
|
- |
1 coated, 1 uncoated and separate sample for tensile and hardness test are required
Except HST for DN above 300 mm |
230 |
IS 7098 : Part 2 (2011) |
Crosslinked polyethylene insulated thermoplastic sheathed cables - Specification: Part 2 for working voltages from 3.3 kV up to and including 33 kV (Second Revision) |
- |
-
|
Rs. 33750/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
20.13 (Test for Halogen Acid Gas Evolution) |
- |
|
|
|
4.1 (CONDUCTOR) |
- |
|
|
|
4.1.1 (CONDUCTOR) |
- |
|
|
|
5 (INSULATION) |
- |
|
|
|
6 (SCREENING) |
- |
|
|
|
6.1.1 (SCREENING : - Non-metallic — Semiconducting Compound) |
- |
|
|
|
6.1.2 (SCREENING : - Non-magnetic Metallic Tape for Single Core Unscreened and Unarmoured Cables) |
- |
|
|
|
7 (FILLERS AND INNER SHEATH) |
- |
|
|
|
8.1 (ARMOURING) |
- |
|
|
|
8.2 (ARMOURING) |
- |
|
|
|
9 (OUTER SHEATH ) |
- |
|
|
|
10.1 (CONDUCTOR) |
- |
|
|
|
10.2 (CONDUCTOR) |
- |
|
|
|
11 (CONDUCTOR SCREENING) |
- |
|
|
|
12.1 (INSULATION) |
- |
|
|
|
12.2 (INSULATION : Thickness of Insulation) |
- |
|
|
|
12.3 (INSULATION : Tolerance on Thickness of Insulation) |
- |
|
|
|
12.4 (Eccentricity and Ovality) |
- |
|
|
|
12.5 (INSULATION : Application of Insulation) |
- |
|
|
|
13.1 (INSULATION SCREENING) |
- |
|
|
|
13.2 (INSULATION SCREENING) |
- |
|
|
|
13.3 (INSULATION SCREENING) |
- |
|
|
|
13.4 (INSULATION SCREENING) |
- |
|
|
|
14.1 (CORE IDENTIFICATION) |
- |
|
|
|
14.1.1 (CORE IDENTIFICATION) |
- |
|
|
|
15.1 (LAVING UP OF CORES) |
- |
|
|
|
16.1 (INNER SHEATH (COMMON COVERING)) |
- |
|
|
|
16.2 (INNER SHEATH (COMMON COVERING)) |
- |
|
|
|
16.2.1 (INNER SHEATH (COMMON COVERING)) |
- |
|
|
|
16.3 (INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
|
|
|
16.3.1 (INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
|
|
|
17.1 (ARMOURING : Application ) |
- |
|
|
|
17.1.1 (ARMOURING ) |
- |
|
|
|
17.1.2 (ARMOURING ) |
- |
|
|
|
17.1.3 (ARMOURING ) |
- |
|
|
|
17.2 (ARMOURING : Type of armour ) |
- |
|
|
|
17.2.1 (ARMOURING : Type of armour ) |
- |
|
|
|
17.2 (ARMOURING : Coverage ) |
- |
|
|
|
17.3 (ARMOURING : Dimension ) |
- |
|
|
|
17.4 (ARMOURING : Joints) |
- |
|
|
|
16.4 (ARMOURING : Resistance) |
- |
|
|
|
18.1 (OUTER SHEATH) |
- |
|
|
|
18.2 (OUTER SHEATH: Colour) |
- |
|
|
|
18.3 (Thicknes of outer sheath : average ) |
- |
|
|
|
18.3 (Thicknes of outer sheath : minimum ) |
- |
|
|
|
19.1 i) a) (Annealing test (for copper)) |
- |
|
|
|
19.1 i) b) (Tensile test (for aluminium) - Before stranding ) |
- |
|
|
|
19.1 i) b) (Tensile test (for aluminium) - After stranding ) |
- |
|
|
|
19.1 i) c) (Wrapping test ( for aluminium)) |
- |
|
|
|
19.1 i) d) (Resistance test - Main conductor ) |
- |
|
|
|
19.1 i) d) (Resistance test - Neutral conductor ) |
- |
|
|
|
19.1 iii) a) (Phyaical tests for insulation : Tensile Test) |
- |
|
|
|
19.1 iii) a) (Phyaical tests for insulation : Elongation ) |
- |
|
|
|
19.1 iii) b) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
|
|
|
19.1 iii) b) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
|
|
|
19.1 vi) b) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
|
|
|
19.1 iii) b) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
|
|
|
19.1 iii) d) (Phyaical tests for insulation : Hot set ) |
- |
|
|
|
19.1 iii) d) (Phyaical tests for insulation : Permanent set ) |
- |
|
|
|
19.1 iii) e) (Phyaical tests for insulation : Shrinkage ) |
- |
|
|
|
19.1 iii) e) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
|
|
|
19.1 iii) f) (Insulation: Waterabsorption(gravimetric)) |
- |
|
|
|
19.1 v) b) (Volume resistivity) |
- |
|
|
|
19.1 vi) a) (Physical tests for outer sheath : Tensile stregth ) |
- |
|
|
|
19.1 vi) a) (Physical tests for outer sheath : Elongation ) |
- |
|
|
|
19.1 vi) b) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
|
|
|
19.1 iii) a) (Phyaical tests for insulation : Tensile Test) |
- |
|
|
|
19.1 vi) b) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
|
|
|
19.1 vi) b) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
|
|
|
19.1 vi) b) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
|
|
|
19.1 vi) b) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
|
|
|
19.1 vi) c) (Phyaical tests for Sheath : Shrinkage ) |
- |
|
|
|
19.1 vi) c) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
|
|
|
19.1 vi) d) (Sheath : Hot deformation) |
- |
|
|
|
19.1 vi) e) (Loss of massIn air oven) |
- |
|
|
|
19.1 vi) f) (Sheath : Heat shock test) |
- |
|
|
|
19.1 vi) g) (Sheath : Thermalstability) |
- |
|
|
|
20.7 (High voltage test) |
- |
|
|
|
20.8 (Flammability test) |
- |
|
|
|
20.1 (Oxygen Index Test) |
- |
|
|
|
20.11 (Flame Retardance Test on Single Cables) |
- |
|
|
|
20.12 (Flame Retardance Test on Bunched Cables) |
- |
|
|
|
20.14 ( Test for Smoke Density) |
- |
|
|
|
20.15 (Temperature Index) |
- |
|
|
|
21.1 (IDENTIFICATION : Manufacturer's Identification) |
- |
|
|
|
21.2 (IDENTIFICATION : Cable Identification) |
- |
|
|
|
21.3 (IDENTIFICATION : Cable Code) |
- |
|
|
|
|
Partial
|
|
- |
Test facility is complete for Chemical
Except Cl.20.9 Ageing Test on complete cable, Cl.20.2 Partial discharge, impulse , Cl.20.7 HVT(above 10 kV), Cl.20.3 bending test ,Cl.20.4 Dielectric power factor test ,Cl.20.5 Heat Cycle test,Cl.20.6 Impulse withstand test |
231 |
IS 1875 (1992) |
Carbon steel billets, blooms, slabs and bars for forgings - Specification (Fifth Revision) |
- |
-
|
Rs.5400/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 8 (Diameter, Ovality & Weight) |
- |
|
|
|
Cl 9 (UTM & HBW) |
- |
|
|
|
Cl 7 (Workmanship) |
- |
|
|
|
6.1, 6.2 (carbon) |
- |
|
|
|
6.1, 6.2 (sulphur) |
- |
|
|
|
6.1, 6.2 (silicon ) |
- |
|
|
|
6.1, 6.2 (manganese) |
- |
|
|
|
6.1, 6.2 (phosphorus) |
- |
|
|
|
|
Partial
|
|
- |
Excluding Grain size, Microstructure,Microalloying Elements |
232 |
IS 1825 (1983) |
Specification for aluminium alloy milk cans (Second Revision) |
- |
-
|
Rs 4800.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8 (a) Rated Capacity) |
- |
|
|
|
8 (b) Point of Capacity) |
- |
|
|
|
8 (c) Batch OR Code No.) |
- |
|
|
|
8 (d) BIS Mark) |
- |
|
|
|
8 (e) Manufacturer's Trade Mark ) |
- |
|
|
|
2 (Capacity) |
- |
|
|
|
4 Fig. 1 (Dimensions & Shape) |
- |
|
|
|
4 Fig. 1 (A) |
- |
|
|
|
4 Fig. 1 (B) |
- |
|
|
|
4 Fig. 1 (C ) |
- |
|
|
|
4 Fig. 1 (D) |
- |
|
|
|
4 Fig. 1 (E) |
- |
|
|
|
4 Fig. 1 (F) |
- |
|
|
|
4 Fig. 1 (G) |
- |
|
|
|
4 Fig. 1 (H) |
- |
|
|
|
4 Fig. 1 (BOTTOM BAND) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Drain Holes ) |
- |
|
|
|
4 Fig. 1 (HANDLE ) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (LID) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Dimension) |
- |
|
|
|
4 Fig. 1 (Hole Dia 8 ,2 holes) |
- |
|
|
|
4 Fig. 1 (Hole Dia 12, 3 holes) |
- |
|
|
|
5 (a)Transport cans shall consist of a body, bottom band) |
- |
|
|
|
5 (lid and handles.) |
- |
|
|
|
5 (b)Minimum Thickness(in mm)) |
- |
|
|
|
5 (i) Body and Neck) |
- |
|
|
|
5 (ii) Bottom) |
- |
|
|
|
5 (iii) Lid (Inner)) |
- |
|
|
|
5 (iv) Lid (Outer)) |
- |
|
|
|
5 (c) Mode of Shaping) |
- |
|
|
|
5 (i) If the thickness at shoulder is less than 2.5 mm a ) |
- |
|
|
|
5 (reinforcement ring of 2 mm thickness shall be provided.) |
- |
|
|
|
5 (ii) Brinell Hardness 85 HB Min.) |
- |
|
|
|
5 (d) BOTTOM BAND- It shall be shrunk fit with a ) |
- |
|
|
|
5 (proper locking arrangement on the body. This shall) |
- |
|
|
|
5 (be followed by brazing or welding all round.) |
- |
|
|
|
5 (e) HANDLES (as per Cl 5.6)) |
- |
|
|
|
5 (f) SEALING LUG (as per Cl 5.7)) |
- |
|
|
|
5 (g)Workmanship and Finish- All brazing or welding shall ) |
- |
|
|
|
5 (be sound , free of porosity and shall be finished smooth .) |
- |
|
|
|
5 (h) Mass 6.5 Kg. Min.) |
- |
|
|
|
7 (i) Air Pressure Test (Cl 7.1)) |
- |
|
|
|
7 (ii) Drop Test (Cl 7.2)) |
- |
|
|
|
7 (iii) The cans when filled with water and inverted shall not show any profuse leakage through lids. ) |
- |
|
|
|
|
Partial
|
|
- |
Test facility is complete, Facility for chemical testing is not available |
233 |
IS 4224 (1972) |
Specification for steel wire for staples, pins and clips (First Revision) |
- |
-
|
525 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5 (Sizes and Tolerances - IS 4224) |
- |
|
|
|
7.1 (Tensile Test - IS 1608(Pt -1)) |
- |
|
|
|
4 (Freedom from defects , IS 4224) |
- |
|
|
|
7.2 (Reverse Bend Test--IS 1716) |
- |
|
|
|
|
Complete
|
|
- |
Test facility is complete |
234 |
IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
16.13 (Test for Halogen Acid Gas Evolution) |
- |
|
|
|
3 (CONDUCTOR: MATERIALS) |
- |
|
|
|
4 (INSULATION : MATERIALS) |
- |
|
|
|
5.1 (FILLER AND INNER SHEATH) |
- |
|
|
|
5.2 (FILLER AND INNER SHEATH) |
- |
|
|
|
6 (ARMOURING) |
- |
|
|
|
7 (OUTER SHEATH) |
- |
|
|
|
8.1 (CONDUCTOR: CONSTRUCTION) |
- |
|
|
|
8.2 (PROTECTIVE BARRIER) |
- |
|
|
|
8.3 (SIZE OF NEUTRAL CONDUCTOR) |
- |
|
|
|
9.1 (Insulation Applied by extrusicn) |
- |
|
|
|
9.2 (Thickness of Insulation - Average) |
- |
|
|
|
9.3 (Thickness of Insulation - Minimum) |
- |
|
|
|
9.4 (Application of Insulation) |
- |
|
|
|
10.1 (Core Identification) |
- |
|
|
|
10.2 (Core Identification- Neutral) |
- |
|
|
|
10.3 (Core Identification by number ) |
- |
|
|
|
10.4 (Core Identification by number - Neutral ) |
- |
|
|
|
11 (LAVING UP OF CORES) |
- |
|
|
|
12.1 & 12.2 (Inner sheath : Application) |
- |
|
|
|
12.3 (Thickness of Inner Sheath) |
- |
|
|
|
13.1 (Armouring: Application) |
- |
|
|
|
13.1.2 (Armouring: Coverage ) |
- |
|
|
|
13.1.3 (Armouring: Direction of Lay ) |
- |
|
|
|
13.2 (Type of armour ) |
- |
|
|
|
13.3 (Armouring : Dimensions -Wire Diameter) |
- |
|
|
|
13.3 (Armouring : Dimensions -Formed wire ) |
- |
|
|
|
13.4 (Armour: Joint) |
- |
|
|
|
13.5 (Armouring : Resistance Test) |
- |
|
|
|
13.6 a) (ARMOURING: Tensile Strength) |
- |
|
|
|
13.6 b) (ARMOURING: Elongation ) |
- |
|
|
|
13.6 c) (ARMOURING: Torsion Test (For round wire ) ) |
- |
|
|
|
13.6 d) (ARMOURING: Winding Test(For formed wire)) |
- |
|
|
|
13.6 e) (ARMOURING: Uniformity of zinc coating) |
- |
|
|
|
13.6 f) (ARMOURING: Mass of zinc coating ) |
- |
|
|
|
13.6 g) (ARMOURING: Resistivity) |
- |
|
|
|
14.1 (Outer Sheath : Application) |
- |
|
|
|
14.2 (Colour of outer sheath) |
- |
|
|
|
14.3 (Thickness of outer sheath - AVERAGE) |
- |
|
|
|
14.3 (Thickness of outer sheath - minimum) |
- |
|
|
|
15.1 a) i) (Annealing Test ( For copper wire ) ) |
- |
|
|
|
15.1 a) ii) (Tensile test (for aluminium) - Before stranding ) |
- |
|
|
|
15.1 a) ii) (Tensile test (for aluminium) - After stranding ) |
- |
|
|
|
15.1 a) iii) (Wrapping test (for aluminium)) |
- |
|
|
|
15.1 a) iv) (Resistance test - Neutral conductor) |
- |
|
|
|
15.1 a) iv) (Resistance test - Main conductor) |
- |
|
|
|
15.1 a) iv) (Resistance test - Neutral conductor) |
- |
|
|
|
15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
|
|
|
15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
|
|
|
15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
|
|
|
15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
|
|
|
15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
|
|
|
15.1 d) iii) (Phyaical tests for insulation : Permanent set ) |
- |
|
|
|
15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
|
|
|
15.1 d) iv) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
|
|
|
15.1 d) v) (Insulation: Waterabsorption(gravimetric)) |
- |
|
|
|
15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
|
|
|
15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
|
|
|
15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
|
|
|
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
|
|
|
15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
|
|
|
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
|
|
|
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
|
|
|
15.1 e) v) (Sheath : Hot deformation) |
- |
|
|
|
15.1 e) vi) (Sheath : Heat shock test) |
- |
|
|
|
15.1 e) vii) (Sheath : Thermalstability) |
- |
|
|
|
15.1 f) (INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
|
|
|
16.2 (HIGH VOLTAGE TEST ) |
- |
|
|
|
16.3 (FLAMMABILITY TEST : Period of Burning ) |
- |
|
|
|
16.2 (HIGH VOLTAGE TEST ) |
- |
|
|
|
16.3 (FLAMMABILITY TEST : Period of Burning ) |
- |
|
|
|
16.3 (FLAMMABILITY TEST : Unaffected length ) |
- |
|
|
|
16.9 (Oxygen Index Test) |
- |
|
|
|
16.1 (Flame Retardance Test on Single Cables) |
- |
|
|
|
16.11 (Flame Retardance Test on Bunched Cables) |
- |
|
|
|
16.14 (Temperature Index) |
- |
|
|
|
17.1 (Manufacturer'. identification) |
- |
|
|
|
17.2 (cable Indentification ) |
- |
|
|
|
17.3 (cable Code ) |
- |
|
|
|
|
Partial
|
|
- |
Test facility is complete |
235 |
IS 651 (2007) |
Glazed stoneware pipes and fittings - Specification (Sixth Revision) |
- |
-
|
Rs. 6850/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 7.4 (Acid Resistance Test) |
- |
|
|
|
Clause 7.5 (Alkali Resistance Test) |
- |
|
|
|
7.2 (Hydraulic Test) |
- |
|
|
|
7.3 (Absorption Test) |
- |
|
|
|
11.1-Table 1 (
Mean Thickness of Barrel and of Socket) |
- |
|
|
|
10.1-Table 1 (INTERNAL DIAMETER) |
- |
|
|
|
14-Table 1 (Internal Depth of Socket) |
- |
|
|
|
14-Table 2 (Excess Shoulder Measurment) |
- |
|
|
|
14-Table 3 (Length of Grooving of Spigot) |
- |
|
|
|
12.2 (STRAIGHTNESS OF BARRELS OR STRAIGHT AND TAPER PIPES-Length of Junction) |
- |
|
|
|
13.1-Table 2 (Dimensions of One-Quarter Bends-Internal Diameter) |
- |
|
|
|
13.1-Table 2 (Dimensions of One-Quarter Bends-angle) |
- |
|
|
|
13.1-Table 6 (Dimensions of One-Eighth Taper Bends-D) |
- |
|
|
|
17-Table 10 (Dimensions of Channel Interceptors-A) |
- |
|
|
|
17-Table 10 (Dimensions of Channel Interceptors-G) |
- |
|
|
|
17-Table 11 (Dimensions of Round Mouth Gully traps-Type) |
- |
|
|
|
17-Table 11 (Dimensions of Round Mouth Gully traps-A) |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-G) |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-F') |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-F) |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-E) |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-D) |
- |
|
|
|
17-Table 12 (Dimensions of Square Mouth Gully Traps-Size) |
- |
|
|
|
14 (The interior of the sockets shall be conical, having a minimum taper) |
- |
|
|
|
13.1-Table 3 (Dimensions of One-Eighth Bends-r) |
- |
|
|
|
13.1-Table 5 (Dimension of One-Quarter Taper Bends-r) |
- |
|
|
|
17-Table 10 (Dimensions of Channel Interceptors-C) |
- |
|
|
|
|
Partial
|
|
- |
Test facility is complete for Chemical
Except HST and compression test For size above 300 mm |
236 |
IS 458 (2003) |
Precast concrete pipes(With And Without Reinforcement) - Specification (Fourth Revision) |
- |
-
|
- View breakup
Rs.4200/- (excl. Split tensile strength test, Hydrostatic test, Three edge bearing test and test for aggregates) and testing charges as per relevant referred Iss
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1.1 (a) Identification) |
- |
|
|
|
5.1.1 (b) Date of cast ) |
- |
|
|
|
5.1.1 (c) Date of test ) |
- |
|
|
|
5.1.1 (d) i) Curing-when received dry the specimen shall be kept in water for 24 hr) |
- |
|
|
|
5.1.1 (ii) weight) |
- |
|
|
|
5.1.1 (iv) Cross-sectional area ( in mm2)) |
- |
|
|
|
5.1.1 (v) Max. Load ( in kN) ) |
- |
|
|
|
5.1.1 (vi) Compressive strength, N/mm2 ) |
- |
|
|
|
5.1.1 (vii) Fracture) |
- |
|
|
|
5.1.1 (viii) Individual variation of average ) |
- |
|
|
|
|
Partial
|
|
- |
Standard has been revised as IS 458 : 2021 Except three edge load and HST, Split tesnsile and compressive strength upto 1000KN load- |
237 |
IS 624 (2003) |
Bicycles - Rims - Specification (Fourth Revision) |
- |
-
|
- View breakup
Rs. 2850/- (for manufacture and finish, finish only for Ni/Cr coating thickness) + Material testing charges as per referred ISS.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7 (FINISH) |
- |
|
|
|
3.2 (SHAPES AND DIMENSIONS) |
- |
|
|
|
9 (COMPRESSION TEST) |
- |
|
|
|
7 (chem) (FINISH) |
- |
|
|
|
|
Partial
|
|
- |
Except dimensions clause 3.2 & 3.2.1 Circumference, finish test facility only for Ni/Cr coating thickness |
238 |
IS 1785 : Part 2 (1983) |
Specification for plain hard drawn steel wire for prestressed concrete: Part 2 as - Drawn wire (First Revision) |
- |
-
|
Rs 3000/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5.1 (Diameter) |
- |
|
|
|
Cl 5.1.2 (Weight) |
- |
|
|
|
Cl 6.1 (Tensile Test On UTM) |
- |
|
|
|
Cl 6.3 (Tensile Test On UTM) |
- |
|
|
|
3.1.1 (PHOSPHORUS) |
- |
|
|
|
3.1.1 (SULPHUR) |
- |
|
|
|
Cl. 7.5 (Ductility/ Reverse Bend Test) |
- |
|
|
|
|
Partial
|
|
- |
Test facility is complete for Chemical
Except Proof Stress |
239 |
IS 1729 (2002) |
Cast iron/ductile iron drainage pipes and pipe fittings for over ground non-pressure pipeline socket and spigot series (Second Revision) |
- |
-
|
Rs. 2850/- and testing charges as per referred Iss View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1 (Tensile Strrngth - IS1608(Pt-1)) |
- |
|
|
|
5.1 (Elongation - IS 1608(Pt-1)) |
- |
|
|
|
5.4 (Hardness- IS 1500) |
- |
|
|
|
7 (Leakage Test - IS 1729) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, a) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, b) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, c) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, d) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, e) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, f) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, g) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, h) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, i) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, j) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, k) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, l) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, m) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, n) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, p) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, q) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, r) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, r1) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, r2) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, s) |
- |
|
|
|
8.2-Table 1 to 32 (Dimension, t) |
- |
|
|
|
11 (Coating Test at 65degree Celcius ) |
- |
|
|
|
11 (Coating Test at 0degree Celcius) |
- |
|
|
|
5.3 (Casting Defects) |
- |
|
|
|
|
Partial
|
|
- |
Test facility is complete and Standard has been revised as IS 1729 : 2023
Facility for chemical testing is not available |
240 |
IS 1489 : Part 2 (2015) |
Portland - Pozzolana cement - Specification: Part 2 calcined clay based |
- |
-
|
Rs.8420/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 - Table - 1 i (Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 ii (Magnesia - Cl 7.2 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 iii (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 v (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 vi ( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
|
|
|
7 -Table 2- i (Fineness 4031 Part 2) |
- |
|
|
|
7 -Table 2- ii- a (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
7 -Table 2- ii- a (Expansion after aeration - 4031 Part 3) |
- |
|
|
|
7 -Table 2- ii- b (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
7 -Table 2- ii- b (Expansion after aeration- 4031 Part 3) |
- |
|
|
|
7 -Table 2- iii- a (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
7 -Table 2-iii- b (Setting Time Final- 4031 Part 5) |
- |
|
|
|
7 -Table 2- iv- a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
7 -Table 2- iv- b (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
7 -Table 2- iv- c (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
7 -Table 2- vi (Drying Shrinkage- IS 4031 Part 10) |
- |
|
|
|
|
Partial
|
|
- |
Test facility is complete for Chemical Except Transverse Strength Test |