| 61 |
IS 4159 (2002) |
Mineral filled sheathed heating elements - Specification (Third Revision) |
- |
8800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
20 |
|
Test |
| Cl.8 of IS 4159:2002 & IS 302‐1:2008(Protection Against Electric Shock) |
- |
200 |
|
Test |
| Cl.10 of IS 4159:2002 &
IS 302-1:2008(Input & Current) |
- |
400 |
|
Test |
| Cl.11 of IS 4159:2002 & IS 302‐1:2008(Temperature Rise) |
- |
100 |
|
Test |
| Cl.13 of IS 4159:2002 & IS 302-1: 2008(Electrical Insulation and Leakage Current at Operating Temperature) |
- |
250 |
|
Test |
| Cl.15 of IS 4159:2002 & IS 302-1: 2008(Moisture Resistance) |
- |
200 |
|
Test |
| Cl.16 of IS 4159:2002 & IS 302-1: 2008(Insulation Resistance & Electric Strength (after Humidity Treatment)) |
- |
250 |
|
Test |
| Cl.18 of IS 4159:2002(Endurance Test
) |
- |
500 |
|
Test |
| Cl.19 of IS 4159:2002 & IS 302-1: 2008(Abnormal Operation) |
- |
100 |
|
Test |
| Cl.20 of IS 4159:2002 & IS 302-1: 2008(Stability & Mechanical Hazards
) |
- |
230 |
|
Test |
| Cl.21 of IS 4159:2002 & IS 302-1: 2008(Mechanical Strength) |
- |
100 |
|
Test |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
20 |
|
Test |
| Cl.23 of IS 4159:2002 &
IS 302-1: 2008(Internal Wiring
) |
- |
50 |
|
Test |
| Cl.24 of IS 4159:2002 &
IS 302-1: 2008(Component ) |
- |
100 |
|
Test |
| Cl.25 of IS 4159:2002 & IS 302-1: 2008(Supply connection & external flexible cables & cords) |
- |
200 |
|
Test |
| Cl.26 of IS 4159:2002 & IS 302-1: 2008(Terminals for External Conductors) |
- |
30 |
|
Test |
| Cl.27 of IS 4159:2002 & IS 302-1: 2008(Provision for Earthing) |
- |
50 |
|
Test |
| Cl.28 of IS 4159:2002 & IS 302-1: 2008(Screws & Connection ) |
- |
50 |
|
Test |
| Cl. 29 of IS 4159:2002 &
IS 302-1: 2008(Creepage Distances & Clearances) |
- |
250 |
|
Test |
| Cl. 30 of IS 4159:2002 &
IS 302-1: 2008(Resistance to Heat, Fire and Tracking) |
- |
250 |
|
Test |
| Cl. 31 of IS 4159:2002 &
IS 302-1: 2008(Resistance to Rusting) |
- |
500 |
|
Test |
| Cl. 102 of IS 4159:2002(Leakage & Hydrostatic Strength Test
(for Oil heating elements)
) |
- |
250 |
|
Test |
| Cl.6 of IS 4159:2002 &
IS 302-1:2008
(Classification) |
- |
200 |
|
- |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
20 |
|
- |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
20 |
|
- |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
20 |
|
- |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
20 |
|
- |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
20 |
|
- |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
20 |
|
- |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
20 |
|
- |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
20 |
|
- |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
20 |
|
- |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
20 |
|
- |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
20 |
|
- |
| Cl.11 of IS 4159:2002 & IS 302‐1:2008(Temperature Rise) |
- |
100 |
|
- |
| Cl.11 of IS 4159:2002 & IS 302‐1:2008(Temperature Rise) |
- |
100 |
|
- |
| Cl.11 of IS 4159:2002 & IS 302‐1:2008(Temperature Rise) |
- |
100 |
|
- |
| Cl.11 of IS 4159:2002 & IS 302‐1:2008(Temperature Rise) |
- |
100 |
|
- |
| Cl.11 of IS 4159:2002 & IS 302‐1:2008(Temperature Rise) |
- |
100 |
|
- |
| Cl.13 of IS 4159:2002 & IS 302-1: 2008(Electrical Insulation and Leakage Current at Operating Temperature) |
- |
250 |
|
- |
| Cl.15 of IS 4159:2002 & IS 302-1: 2008(Moisture Resistance) |
- |
200 |
|
- |
| Cl.15 of IS 4159:2002 & IS 302-1: 2008(Moisture Resistance) |
- |
200 |
|
- |
| Cl.16 of IS 4159:2002 & IS 302-1: 2008(Insulation Resistance & Electric Strength (after Humidity Treatment)) |
- |
250 |
|
- |
| Cl.19 of IS 4159:2002 & IS 302-1: 2008(Abnormal Operation) |
- |
100 |
|
- |
| Cl.19 of IS 4159:2002 & IS 302-1: 2008(Abnormal Operation) |
- |
100 |
|
- |
| Cl.19 of IS 4159:2002 & IS 302-1: 2008(Abnormal Operation) |
- |
100 |
|
- |
| Cl.19 of IS 4159:2002 & IS 302-1: 2008(Abnormal Operation) |
- |
100 |
|
- |
| Cl.19 of IS 4159:2002 & IS 302-1: 2008(Abnormal Operation) |
- |
100 |
|
- |
| Cl.19 of IS 4159:2002 & IS 302-1: 2008(Abnormal Operation) |
- |
100 |
|
- |
| Cl.21 of IS 4159:2002 & IS 302-1: 2008(Mechanical Strength) |
- |
100 |
|
- |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
20 |
|
- |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
20 |
|
- |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
20 |
|
- |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
20 |
|
- |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
20 |
|
- |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
20 |
|
- |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
20 |
|
- |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
20 |
|
- |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
20 |
|
- |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
20 |
|
- |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
20 |
|
- |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
20 |
|
- |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
20 |
|
- |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
20 |
|
- |
| Cl.23 of IS 4159:2002 &
IS 302-1: 2008(Internal Wiring
) |
- |
50 |
|
- |
| Cl.23 of IS 4159:2002 &
IS 302-1: 2008(Internal Wiring
) |
- |
50 |
|
- |
| Cl.23 of IS 4159:2002 &
IS 302-1: 2008(Internal Wiring
) |
- |
50 |
|
- |
| Cl.23 of IS 4159:2002 &
IS 302-1: 2008(Internal Wiring
) |
- |
50 |
|
- |
| Cl.23 of IS 4159:2002 &
IS 302-1: 2008(Internal Wiring
) |
- |
50 |
|
- |
| Cl.23 of IS 4159:2002 &
IS 302-1: 2008(Internal Wiring
) |
- |
50 |
|
- |
| Cl.23 of IS 4159:2002 &
IS 302-1: 2008(Internal Wiring
) |
- |
50 |
|
- |
| Cl.23 of IS 4159:2002 &
IS 302-1: 2008(Internal Wiring
) |
- |
50 |
|
- |
| Cl.24 of IS 4159:2002 &
IS 302-1: 2008(Component ) |
- |
100 |
|
- |
| Cl.26 of IS 4159:2002 & IS 302-1: 2008(Terminals for External Conductors) |
- |
30 |
|
- |
| Cl.26 of IS 4159:2002 & IS 302-1: 2008(Terminals for External Conductors) |
- |
30 |
|
- |
| Cl.26 of IS 4159:2002 & IS 302-1: 2008(Terminals for External Conductors) |
- |
30 |
|
- |
| Cl.26 of IS 4159:2002 & IS 302-1: 2008(Terminals for External Conductors) |
- |
30 |
|
- |
| Cl.26 of IS 4159:2002 & IS 302-1: 2008(Terminals for External Conductors) |
- |
30 |
|
- |
| Cl.26 of IS 4159:2002 & IS 302-1: 2008(Terminals for External Conductors) |
- |
30 |
|
- |
| Cl.26 of IS 4159:2002 & IS 302-1: 2008(Terminals for External Conductors) |
- |
30 |
|
- |
| Cl.26 of IS 4159:2002 & IS 302-1: 2008(Terminals for External Conductors) |
- |
30 |
|
- |
| Cl.26 of IS 4159:2002 & IS 302-1: 2008(Terminals for External Conductors) |
- |
30 |
|
- |
| Cl.26 of IS 4159:2002 & IS 302-1: 2008(Terminals for External Conductors) |
- |
30 |
|
- |
| Cl.26 of IS 4159:2002 & IS 302-1: 2008(Terminals for External Conductors) |
- |
30 |
|
- |
| Cl.27 of IS 4159:2002 & IS 302-1: 2008(Provision for Earthing) |
- |
50 |
|
- |
| Cl.27 of IS 4159:2002 & IS 302-1: 2008(Provision for Earthing) |
- |
50 |
|
- |
| Cl.27 of IS 4159:2002 & IS 302-1: 2008(Provision for Earthing) |
- |
50 |
|
- |
| Cl.27 of IS 4159:2002 & IS 302-1: 2008(Provision for Earthing) |
- |
50 |
|
- |
| Cl.28 of IS 4159:2002 & IS 302-1: 2008(Screws & Connection ) |
- |
50 |
|
- |
| Cl.28 of IS 4159:2002 & IS 302-1: 2008(Screws & Connection ) |
- |
50 |
|
- |
| Cl.28 of IS 4159:2002 & IS 302-1: 2008(Screws & Connection ) |
- |
50 |
|
- |
| Cl. 29 of IS 4159:2002 &
IS 302-1: 2008(Creepage Distances & Clearances) |
- |
250 |
|
- |
| Cl. 30 of IS 4159:2002 &
IS 302-1: 2008(Resistance to Heat, Fire and Tracking) |
- |
250 |
|
- |
| Cl. 33.1 of IS 4159:2002(Finish Test
) |
- |
200 |
|
- |
| Cl. 102 of IS 4159:2002(Leakage & Hydrostatic Strength Test
(for Oil heating elements)
) |
- |
300 |
|
- |
|
- |
- - |
| 62 |
IS 369 (2019) |
Household electric direct - Acting room heaters - Performance requirements (Fourth Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
300 |
|
Test |
| Cl.8 of IS 302-2-30:2007 &IS:302-1:2008(Protection Against Access to Live Parts) |
- |
300 |
|
Test |
| Cl.10 of IS 302-2-30:2007 &IS:302-1:2008(Power Input and Current) |
- |
400 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
550 |
|
Test |
| Cl.13 of IS 302-2-30:2007 &IS:302-1:2008(Leakage Current & Electric Strength at operating temp) |
- |
650 |
|
Test |
| Cl.14 of IS 302-2-30:2007 &IS:302-1:2008(Transient Over Voltages) |
- |
400 |
|
Test |
| Cl.15 of IS 302-2-30:2007 &IS:302-1:2008(Moisture Resistance) |
- |
500 |
|
Test |
| Cl.16 of IS 302-2-30:2007 &IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
500 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
600 |
|
Test |
| Cl.20 of IS 302-2-30:2007 &IS:302-1:2008(Stability & Mechanical Hazards) |
- |
400 |
|
Test |
| Cl.21 of IS 302-2-30:2007 &IS:302-1:2008(Mechanical Strength) |
- |
500 |
|
Test |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
400 |
|
Test |
| Cl.23 of IS 302-2-30:2007 &IS:302-1:2008(Internal Wiring) |
- |
400 |
|
Test |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
500 |
|
Test |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
250 |
|
Test |
| Cl.26 of IS 302-2-30:2007 &IS:302-1:2008(Terminal for External Conductors) |
- |
200 |
|
Test |
| Cl.27 of IS 302-2-30:2007 &IS:302-1:2008(Provision for Earthing) |
- |
400 |
|
Test |
| Cl.28 of IS 302-2-30:2007 &IS:302-1:2008(Screws and Connections) |
- |
200 |
|
Test |
| Cl.29 of IS 302-2-30:2007 &IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation.) |
- |
300 |
|
Test |
| Cl.30 of IS 302-2-30:2007 &IS:302-1:2008(Resistance to Heat and Fire.) |
- |
350 |
|
Test |
| Cl.31 of IS 302-2-30:2007 &IS:302-1:2008(Resistance to Rusting) |
- |
350 |
|
Test |
| Cl.18 of IS 302-2-30:2007 (Endurance) |
- |
0 |
|
Test |
| Cl.8 of IS 369:2019(Temperature rises of air-outlet grilles and external surfaces) |
- |
500 |
|
Test |
| Cl.9 of IS 369:2019(Temperature rises of surfaces surrounding the heater) |
- |
550 |
|
Test |
| Cl.10 of IS 369:2019(Warming-up time of the heater) |
- |
500 |
|
Test |
| Cl.11 of IS 369:2019(Stability of room temperature) |
- |
650 |
|
Test |
| Cl.12 of IS 369:2019(Set-back) |
- |
650 |
|
Test |
| Cl.13 of IS 369:2019(Frost protection temperature) |
- |
650 |
|
Test |
| Cl.14 of IS 369:2019(Inrush current) |
- |
500 |
|
Test |
| Cl.15 of IS 369:2019(Effect of radiant heat) |
- |
500 |
|
Test |
| Cl.16 of IS 369:2019(Usable power) |
- |
600 |
|
Test |
| Cl.6 of IS 302-2-30:2007(Classification) |
- |
200 |
|
Test |
| Cl.6 of IS 302-2-30:2007(Classification) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
0 |
|
Test |
| Cl.13 of IS 302-2-30:2007 &IS:302-1:2008(Leakage Current & Electric Strength at operating temp) |
- |
0 |
|
Test |
| Cl.14 of IS 302-2-30:2007 &IS:302-1:2008(Transient Over Voltages) |
- |
0 |
|
Test |
| Cl.14 of IS 302-2-30:2007 &IS:302-1:2008(Transient Over Voltages) |
- |
0 |
|
Test |
| Cl.14 of IS 302-2-30:2007 &IS:302-1:2008(Transient Over Voltages) |
- |
0 |
|
Test |
| Cl.15 of IS 302-2-30:2007 &IS:302-1:2008(Moisture Resistance) |
- |
0 |
|
Test |
| Cl.16 of IS 302-2-30:2007 &IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.21 of IS 302-2-30:2007 &IS:302-1:2008(Mechanical Strength) |
- |
0 |
|
Test |
| Cl.21 of IS 302-2-30:2007 &IS:302-1:2008(Mechanical Strength) |
- |
0 |
|
Test |
| Cl.21 of IS 302-2-30:2007 &IS:302-1:2008(Mechanical Strength) |
- |
0 |
|
Test |
| Cl.21 of IS 302-2-30:2007 &IS:302-1:2008(Mechanical Strength) |
- |
40 |
|
Test |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
0 |
|
Test |
| Cl.23 of IS 302-2-30:2007 &IS:302-1:2008(Internal Wiring) |
- |
0 |
|
Test |
| Cl.23 of IS 302-2-30:2007 &IS:302-1:2008(Internal Wiring) |
- |
0 |
|
Test |
| Cl.23 of IS 302-2-30:2007 &IS:302-1:2008(Internal Wiring) |
- |
0 |
|
Test |
| Cl.23 of IS 302-2-30:2007 &IS:302-1:2008(Internal Wiring) |
- |
0 |
|
Test |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
0 |
|
Test |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
0 |
|
Test |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
0 |
|
Test |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
0 |
|
Test |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
0 |
|
Test |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
0 |
|
Test |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
0 |
|
Test |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Test |
| Cl.27 of IS 302-2-30:2007 &IS:302-1:2008(Provision for Earthing) |
- |
0 |
|
Test |
| Cl.29 of IS 302-2-30:2007 &IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation.) |
- |
0 |
|
Test |
| Cl.30 of IS 302-2-30:2007 &IS:302-1:2008(Resistance to Heat and Fire.) |
- |
250 |
|
Test |
| Cl.7 of IS 369:2019(Dimensions) |
- |
0 |
|
Test |
| Cl.7 of IS 369:2019(Dimensions) |
- |
0 |
|
Test |
| Cl.7 of IS 369:2019(Dimensions) |
- |
0 |
|
Test |
| Cl.8 of IS 369:2019(Temperature rises of air-outlet grilles and external surfaces) |
- |
0 |
|
Test |
| Cl.8 of IS 369:2019(Temperature rises of air-outlet grilles and external surfaces) |
- |
0 |
|
Test |
| Cl.9 of IS 369:2019(Temperature rises of surfaces surrounding the heater) |
- |
0 |
|
Test |
| Cl.9 of IS 369:2019(Temperature rises of surfaces surrounding the heater) |
- |
0 |
|
Test |
| Cl.9 of IS 369:2019(Temperature rises of surfaces surrounding the heater) |
- |
0 |
|
Test |
| Cl.9 of IS 369:2019(Temperature rises of surfaces surrounding the heater) |
- |
0 |
|
Test |
| Cl.9 of IS 369:2019(Temperature rises of surfaces surrounding the heater) |
- |
0 |
|
Test |
| Cl.11 of IS 369:2019(Stability of room temperature) |
- |
0 |
|
Test |
| Cl.11 of IS 369:2019(Stability of room temperature) |
- |
0 |
|
Test |
| Cl.11 of IS 369:2019(Stability of room temperature) |
- |
0 |
|
Test |
| Cl.15 of IS 369:2019(Effect of radiant heat) |
- |
0 |
|
Test |
| Cl.15 of IS 369:2019(Effect of radiant heat) |
- |
0 |
|
Test |
|
- |
- - |
| 63 |
IS 302 : Part 2 : Sec 26 (2014) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 26 clocks (First Revision) |
- |
30000 View breakup
Rs.30000/- For Electronic Clocks with mains power
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
1000 |
|
nil |
| 8(Protection against live parts) |
- |
1000 |
|
nil |
| 10(POWER INPUT AND CURRENT) |
- |
2000 |
|
nil |
| 11(HEATING) |
- |
2000 |
|
nil |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1000 |
|
nil |
| 14(TRANSIENT OVERVOLTAGES) |
- |
1000 |
|
nil |
| 15(MOISTURE RESISTANCE) |
- |
2000 |
|
nil |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1000 |
|
nil |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
2000 |
|
nil |
| 19(ABNORMAL OPERATION) |
- |
2000 |
|
nil |
| 21(MECHANICAL STRENGTH) |
- |
2000 |
|
nil |
| 22(CONSTRUCTION) |
- |
1000 |
|
nil |
| 23(INTERNAL WIRING) |
- |
1000 |
|
nil |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
1000 |
|
nil |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
nil |
| 27(PROVISION FOR EARTHING) |
- |
1000 |
|
nil |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
nil |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
1000 |
|
nil |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
2000 |
|
nil |
| 31(RESISTANCE TO RUSTING) |
- |
2000 |
|
nil |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
1000 |
|
nil |
| 5(General conditions for the tests) |
- |
500 |
|
nil |
| 6.0(Classification) |
- |
500 |
|
nil |
|
- |
- Excluding:
EMI/EMC (Cl.19.11.4.1 to 19.11.4.7), Critical Components (Cl. 24), Capacitor and RC units RF Suppression X-Y capacitor, PCB Material, Inductor SMPS Transformer, MOV/VDR, Relays, Power cord, Thermal Cut-out / Thermostat Appliance connector / Inlet Door Interlock Switches, IP category, Enclosure insulating, Bridging resistor (Cl.24.0). |
| 64 |
IS 302 : Part 2 : Sec 25 (2014) |
Safety of household and similar electrical appliances: Part 2 Particular requirements: Section 25 Microwave ovens |
- |
45000 View breakup
Rs.45000/- For Microwave Oven
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
1000 |
|
Nil |
| 8(Protection against live parts) |
- |
1000 |
|
Nil |
| 10(POWER INPUT AND CURRENT) |
- |
1000 |
|
Nil |
| 11(HEATING) |
- |
5000 |
|
Nil |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
500 |
|
Nil |
| 14(IMPULSE VOLTAGE TEST) |
- |
1000 |
|
Nil |
| 15(HUMIDITY TREATMENT TEST) |
- |
4000 |
|
Nil |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1000 |
|
Nil |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
5000 |
|
Nil |
| 18(ENDURANCE) |
- |
10000 |
|
Nil |
| 19(ABNORMAL OPERATION) |
- |
3000 |
|
Nil |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
1000 |
|
Nil |
| 21(MECHANICAL STRENGTH) |
- |
500 |
|
Nil |
| 22(CONSTRUCTION) |
- |
500 |
|
Nil |
| 23(INTERNAL WIRING) |
- |
500 |
|
Nil |
| 24(COMPONENTS) |
- |
1500 |
|
Nil |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
1000 |
|
Nil |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
Nil |
| 27(PROVISION FOR EARTHING) |
- |
1000 |
|
Nil |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
Nil |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
500 |
|
Nil |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
1000 |
|
Nil |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
Nil |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
1000 |
|
Nil |
| 6.0(Classification) |
- |
500 |
|
nil |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
500 |
|
nil |
|
- |
- Excluding :
EMI/EMC (Cl.19.11.4.1 to 19.11.4.7), Automatic cord reel (Cl. 22.16), Software (Cl.22.46), Interlocks (Cl.22.106), Components (Cl.24), Appliance for onboard sgip (Annex-BB), Salt spray test (Annex-CC), Magnetron, HV transformer capacitor diode, Capacitor and RC units RF Suppression X-Y capacitor, PCB Material, Inductor SMPS Transformer, MOV/VDR, Relays, Power cord, Thermal Cut-out / Thermostat Appliance connector / Inlet Door Interlock Switches, IP category, Enclosure insulation material, Bridging resistor (Cl.24.0). |
| 65 |
IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
- |
50000 View breakup
Rs.50,000/- For Adapters for Household and Similar Electrical Appliances
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1.1(Protection against live parts in all positions) |
- |
250 |
|
nil |
| 8.1.2(Protection against live parts in openings) |
- |
250 |
|
nil |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
250 |
|
nil |
| 8.1.4(Protection against live parts against protective impedance) |
- |
250 |
|
nil |
| 10.1(Power input) |
- |
500 |
|
nil |
| 10.2(Current input) |
- |
500 |
|
nil |
| 11.2(General) |
- |
2500 |
|
nil |
| 11.3(Heating) |
- |
2500 |
|
nil |
| 13.1(General) |
- |
200 |
|
nil |
| 13.2(Leakage current at operating temperature) |
- |
400 |
|
nil |
| 13.3(Electric Strength at operating temperature) |
- |
400 |
|
nil |
| 14(Transient Over Voltages) |
- |
3000 |
|
nil |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
2500 |
|
nil |
| 15.3(Humidity Test) |
- |
2500 |
|
nil |
| 16.1(General) |
- |
100 |
|
nil |
| 16.2(Leakage Current (after Clause 15)) |
- |
900 |
|
nil |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
nil |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
3000 |
|
nil |
| 19(Abnormal Operation) |
- |
5000 |
|
nil |
| 20(Stability test) |
- |
2000 |
|
nil |
| 21(Mechanical Strength Test) |
- |
2000 |
|
nil |
| 22(Construction verification related test) |
- |
2000 |
|
nil |
| 23(General) |
- |
2000 |
|
nil |
| 25(Supply connection and external flexible cords) |
- |
2000 |
|
nil |
| 26(Terminals for external conductors) |
- |
1000 |
|
nil |
| 27(Provision for earthing) |
- |
2000 |
|
nil |
| 28(Screw test and connections) |
- |
1000 |
|
nil |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
nil |
| 30.1(Ball pressure test) |
- |
600 |
|
nil |
| 30.2(Glow Wire Test) |
- |
800 |
|
nil |
| 30.2(Needle Flame Test) |
- |
600 |
|
nil |
| 31(Resistance to Rusting) |
- |
2000 |
|
nil |
| 7(Marking and instructions) |
- |
1000 |
|
nil |
| 11.1(General) |
- |
100 |
|
nil |
| 9(Starting of motor operation test requirements and tests) |
- |
500 |
|
nil |
| 15.2(Spillage Test) |
- |
300 |
|
nil |
| 16.0(General) |
- |
100 |
|
nil |
| 18(Endurance Test requirements and tests) |
- |
500 |
|
nil |
| 24(Components) |
- |
500 |
|
nil |
| 5(General conditions for tests) |
- |
0 |
|
nil |
| 6(Classification- IS 302-1) |
- |
0 |
|
nil |
|
- |
- Excluding: Cl 19.11.4.1 to 19.11.4.7 (EMI/EMC Tests), Component (Cl.24)
"(1)Cooking ranges, hobs, ovens and similar appliances, (2)Commercial Dispensing Appliances and Vending Machines, (3) spin extractors
(For testing charges please refer relevant Part 2 standard in LIMS)" |
| 66 |
IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
45000 View breakup
• Rs.28,500/- for Wireless key boards
• Rs.45,000/- for Laptop/ notebook/ tablet, Set top box, Visual display unit, video monitor of screen size upto 66”, Printer, Plotters, Scanners, Telephone answering machine, Automatic data processing machine, Power adaptor for IT equipments, Mobile phone, Cash registers, Point of sale terminals, Copying machine/ duplicator, Smart card readers, Mail Processing Machine/ Postage machine/ Franking machine, Passport reader, Power banks for use in portable applications, USB driven Barcode Reader, Barcode scanner, Iris scanners, Optical Fingerprint scanner & smart Watches, CCTV Cameras/ CCTV Recorder, Automatic Teller Cash Dispensing Machines, Keyboard, USB Type External Hard Disk Drive, USB type External Solid State Storage Devices, Standalone Switch Mode Power supplies (SMPS) with output Voltage 48 V (max.), Digital Camera
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.6(Power interface .) |
- |
500 |
|
Nil |
| 1.7(Markings and instructions) |
- |
400 |
|
Nil |
| 2.1(Protection from electric shock and energy hazards) |
- |
4000 |
|
Nil |
| 2.2(SELV circuits) |
- |
400 |
|
Nil |
| 2.3(TNV circuits) |
- |
3000 |
|
Nil |
| 2.4(Limited current circuits) |
- |
400 |
|
Nil |
| 2.5(Limited power sources .) |
- |
400 |
|
Nil |
| 2.6(Provisions for earthing and bonding) |
- |
3000 |
|
Nil |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
3000 |
|
Nil |
| 2.8(Safety interlocks) |
- |
400 |
|
Nil |
| 2.9(Electrical insulation) |
- |
3000 |
|
Nil |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
400 |
|
Nil |
| 3.1(General) |
- |
800 |
|
Nil |
| 3.2(Connection to a mains supply) |
- |
800 |
|
Nil |
| 3.3(Wiring terminals for connection of external conductors) |
- |
1500 |
|
Nil |
| 3.4(Disconnection from the mains supply) |
- |
800 |
|
Nil |
| 3.5(Interconnection of equipment) |
- |
800 |
|
Nil |
| 4.1(Stability) |
- |
800 |
|
Nil |
| 4.2(Mechanical strength) |
- |
800 |
|
Nil |
| 4.3(Design and construction) |
- |
800 |
|
Nil |
| 4.4(Protection against hazardous moving parts) |
- |
1000 |
|
Nil |
| 4.5(Thermal requirements) |
- |
2000 |
|
Nil |
| 4.6(Openings in enclosures) |
- |
1000 |
|
Nil |
| 4.7(Resistance to fire) |
- |
2000 |
|
Nil |
| 5.1(Touch current and protective conductor curren) |
- |
1000 |
|
Nil |
| 5.2(Electric strength) |
- |
1000 |
|
Nil |
| 5.3(Abnormal operating and fault conditions) |
- |
1000 |
|
Nil |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
1500 |
|
Nil |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
1500 |
|
Nil |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
1000 |
|
Nil |
| 7.1(General) |
- |
1000 |
|
Nil |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
1000 |
|
Nil |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
1000 |
|
Nil |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
1000 |
|
Nil |
| 1.5(Components) |
- |
1000 |
|
Nil |
| Annex B(Motor tests under abnormal conditions) |
- |
1000 |
|
Nil |
| Annex C(Transformers) |
- |
1000 |
|
Nil |
| Annex DD(Requirements for the mounting means of a rack mounted equipment) |
- |
1000 |
|
Nil |
|
- |
- Exclusions: Component (Cl.1.5), safety interlocks: moving parts (C1.2.8.5), Switches & relays (Cl.2.8.7), Semiconductor Devices (opto-coupler test) (Cl.2.10.5.4), AC Power supply cords (Cl. 3.2.5.1), cathode ray Tube (C1.4.2.8), Batteries (Cl.4.3.8), Protection in operator Wedge Probe (Household and home/office document/media shredders) (Cl.4.4.2), Dust, powders, liquids and gases (Cl. 4.3.10), Flammable Liquids (Cl.4.3.12), Ionizing Radiation, (Cl.4.3.13.2), Effect of ultraviolet (UV) radiation on material (Cl.4.3.13.3), Human exposure to ultraviolet (UV) radiation (Cl.4.3.13.4), Effect of Lasers (including LEDs) (Cl.4.3.13.5), Insulating winding wires (Annex U), Household and home/office document/media shredders (Annex-EE), Annex-A3: Bottom of Fire enclosure |
| 67 |
IS 2082 (2018) |
Stationary storage type electric water heaters - Specification (Fifth Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| (Cl.8 of IS 302-2-21:2011)(Protection Against Access to Live Parts) |
- |
200 |
|
Test |
| (Cl.10 of IS 302-2-21: 2011)(Power Input & Current) |
- |
300 |
|
Test |
| (Cl.11 of 302-2-21:2011)(Heating) |
- |
100 |
|
Test |
| (Cl.13 of IS 302-2-21:2011)(Leakage Current ) |
- |
150 |
|
Test |
| (Cl.14ofIS302-2-21:2011)(Transient Over Voltages) |
- |
200 |
|
Test |
| (Cl.15 of IS 302-2-21-2011)(Moisture Resistance) |
- |
100 |
|
Test |
| (Cl.17 of IS 302-2-21:2011)(Overload protection of transformers & associated circuits) |
- |
200 |
|
Test |
| (Cl.19 of IS 302-2-21:2011)(Abnormal Operation) |
- |
50 |
|
Test |
| (Cl.20 of IS 302-2-21:2011)(Stability & Mechanical Hazards) |
- |
100 |
|
Test |
| (Cl.21ofIS302-2-21:2011)(Mechanical strength) |
- |
100 |
|
Test |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
20 |
|
Test |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
10 |
|
Test |
| (Cl.24ofIS302-221:2011)(Component) |
- |
20 |
|
Test |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
Test |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
20 |
|
Test |
| (Cl.27 of IS 302-2-21:2011)(Provision for Earthing) |
- |
50 |
|
Test |
| (Cl.28 of IS 302-2-21:2011)(Screws & Connections) |
- |
50 |
|
Test |
| (Cl.29ofIS302-2-21:2011)(Clearances, Creepage Distances and Solid Insulation) |
- |
100 |
|
Test |
| (Cl.30 of IS 302-2-21:2011)(Resistance to Heat & Fire) |
- |
250 |
|
Test |
| (Cl.31 of IS 302-2-21:2011)(Resistance to Rusting) |
- |
210 |
|
Test |
| (Cl.15 of IS 2082:2018)(Verification of the Rated Capacity) |
- |
250 |
|
Test |
| (Cl.16 of IS 2082:2018)(Standing Loss per 24 Hours) |
- |
1000 |
|
Test |
| (Cl.17 of IS 2082:2018)(Hot Water Output) |
- |
1000 |
|
Test |
| (Cl.18 of IS 2082:2018)( Reheating Time) |
- |
500 |
|
Test |
| (Cl.19 of IS 2082:2018)(Mixing Factor) |
- |
500 |
|
Test |
| (Cl.20 of IS 2082:2018)(Deviation of Dial Calibration) |
- |
150 |
|
Test |
| (Cl.21 of IS 2082:2018)(Cyclic Temperature Variation) |
- |
150 |
|
Test |
| 7(Marking) |
- |
10 |
|
Test |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 7(Marking) |
- |
10 |
|
- |
| 6(Classification ) |
- |
50 |
|
- |
| 6(Classification ) |
- |
50 |
|
- |
| (Cl.11 of 302-2-21:2011)(Heating) |
- |
100 |
|
- |
| (Cl.11 of 302-2-21:2011)(Heating) |
- |
100 |
|
- |
| (Cl.13 of IS 302-2-21:2011)(Electrical Strength at Operating Temperature) |
- |
150 |
|
- |
| (Cl.15 of IS 302-2-21-2011)(Moisture Resistance) |
- |
100 |
|
- |
| (Cl.15 of IS 302-2-21-2011)(Moisture Resistance) |
- |
100 |
|
- |
| (Cl.19 of IS 302-2-21:2011)(Abnormal Operation) |
- |
50 |
|
- |
| (Cl.19 of IS 302-2-21:2011)(Abnormal Operation) |
- |
50 |
|
- |
| (Cl.19 of IS 302-2-21:2011)(Abnormal Operation) |
- |
50 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
10 |
|
- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
10 |
|
- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
10 |
|
- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
10 |
|
- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
10 |
|
- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
10 |
|
- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
10 |
|
- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
10 |
|
- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
10 |
|
- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
10 |
|
- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
10 |
|
- |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
10 |
|
- |
| (Cl.24ofIS302-221:2011)(Component) |
- |
20 |
|
- |
| (Cl.24ofIS302-221:2011)(Component) |
- |
20 |
|
- |
| (Cl.24ofIS302-221:2011)(Component) |
- |
20 |
|
- |
| (Cl.24ofIS302-221:2011)(Component) |
- |
20 |
|
- |
| (Cl.24ofIS302-221:2011)(Component) |
- |
20 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
20 |
|
- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
20 |
|
- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
20 |
|
- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
20 |
|
- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
20 |
|
- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
20 |
|
- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
20 |
|
- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
20 |
|
- |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
20 |
|
- |
| (Cl.27 of IS 302-2-21:2011)(Provision for Earthing) |
- |
50 |
|
- |
| (Cl.27 of IS 302-2-21:2011)(Provision for Earthing) |
- |
50 |
|
- |
| (Cl.27 of IS 302-2-21:2011)(Provision for Earthing) |
- |
50 |
|
- |
| (Cl.27 of IS 302-2-21:2011)(Provision for Earthing) |
- |
50 |
|
- |
| (Cl.27 of IS 302-2-21:2011)(Provision for Earthing) |
- |
50 |
|
- |
| (Cl.30 of IS 302-2-21:2011)(Resistance to Heat & Fire) |
- |
250 |
|
- |
| (Cl.22 of IS 2082:2018)(Finish) |
- |
50 |
|
- |
| Cl.22 of IS 2082:2018(Finish) |
- |
50 |
|
- |
| Cl.21 of IS 2082:2018(Cyclic Temperature Variation) |
- |
150 |
|
- |
| Cl.20 of IS 2082:2018(Deviation of Dial Calibration) |
- |
150 |
|
- |
| Cl.19 of IS 2082:2018(Mixing Factor) |
- |
500 |
|
- |
| Cl.18 of IS 2082:2018( Reheating Time) |
- |
500 |
|
- |
| Cl.17 of IS 2082:2018(Hot Water Output) |
- |
1000 |
|
- |
| Cl.16 of IS 2082:2018(Standing Loss per 24 Hours) |
- |
1000 |
|
- |
| Cl.15 of IS 2082:2018(Verification of the Rated Capacity) |
- |
250 |
|
- |
| Cl.31 of IS 302-2-21:2018(Resistance to Rusting) |
- |
200 |
|
- |
| Cl.30.2 of IS 302-1:2008(Resistance to Heat & Fire : Glow wire test ) |
- |
100 |
|
- |
| Cl.30.1 of IS 302-1:2008(Resistance to Heat & Fire : Ball pressure test ) |
- |
100 |
|
- |
| Cl.29.2 of IS 302-1:2008(Clearances, Creepage Distances and Solid Insulation : Creepage distance ) |
- |
100 |
|
- |
| Cl.29.1 of IS 302-1:2008(Clearances, Creepage Distances and Solid Insulation : Clearance distance ) |
- |
100 |
|
- |
| Cl.28 of IS 302-2-21:2018(Screws & Connections) |
- |
50 |
|
- |
| Cl.27.5 of IS 302-1:2008(Provision for Earthing : ECR ) |
- |
50 |
|
- |
| Cl.27 of IS 302-2-21:2018(Provision for Earthing) |
- |
50 |
|
- |
| Cl.26 of IS 302-2-21: 2018(Terminals for External Conductors) |
- |
50 |
|
- |
| Cl.25.18 of IS 302-1:2008(Supply Connection & External Flexible Cords) |
- |
10 |
|
- |
| Cl.25.15 of IS 302-1:2008(Supply Connection & External Flexible Cords : Cord grip test - displacement ) |
- |
10 |
|
- |
| Cl.25.15 of IS 302-1:2008(Supply Connection & External Flexible Cords : Cord grip test ) |
- |
10 |
|
- |
| Cl.25.12 of IS 302-1:2008(Supply Connection & External Flexible Cords : Moulding of supply cord ) |
- |
10 |
|
- |
| Cl.25.10 of IS 302-1:2008(Supply Connection & External Flexible Cords : Colour of Earthing conductor ) |
- |
10 |
|
- |
| Cl.25.8 of IS 302-2-21:2018(Supply Connection & External Flexible Cords : Resistance of supply cord ) |
- |
10 |
|
- |
| Cl.25.5 of IS 302-1:2008(Supply Connection & External Flexible Cords : Type of attachment ) |
- |
10 |
|
- |
| Cl.25 of IS 302-2-21:2018(Supply Connection & External Flexible Cords : connection to the supply mains) |
- |
10 |
|
- |
| Cl.24.102 of IS 302-221:2018(Component : Operation of thermal cut-out ) |
- |
10 |
|
- |
| Cl.22.104 of
IS 302-2-21:2018(Construction : Outlet of open outlet heater ) |
- |
10 |
|
- |
| Cl.22.103 of
IS 302-2-21:2018(Construction : Operation of Pressure relieve devices ) |
- |
10 |
|
- |
| Cl.22.102 of
IS 302-2-21:2018(Construction : repeated drawing of water temp ) |
- |
10 |
|
- |
| Cl.22.101 of
IS 302-2-21:2018(Construction : rated pressure of closed water heater ) |
- |
10 |
|
- |
| Cl.22.47 of
IS 302-2-21:2018 (Construction : Water pressure test ) |
- |
10 |
|
- |
| Cl.22.44 of
IS 302-1:2008(Construction : Shape and decoration of enclosure) |
- |
10 |
|
- |
| Cl.22.34, Cl 22.35 of
IS 302-1:2008(Construction : Shaft of operating Knobs ) |
- |
10 |
|
- |
| Cl.22.33 of
IS 302-1:2008(Construction : Direct contact of liquids ) |
- |
10 |
|
- |
| Cl 22.26 ,Cl.22.28, Cl 22.29, Cl 22.30 , Cl 22.31, Cl 22.32 of
IS 302-1:2008(Construction : Supplymentry/ double / reinforced insulation for Class II/ Class III appliance ) |
- |
10 |
|
- |
| Cl.22.18 Of
IS 302-1:2008(Construction : Resistance to corrosion ) |
- |
10 |
|
- |
| Cl.22.17 of
IS 302-1:2008(Construction : Spacers ) |
- |
10 |
|
- |
| Cl.22.14 of
IS 302-1:2008(Construction : ragged or sharp edges) |
- |
10 |
|
- |
| Cl.22.12 of
IS 302-1:2008(Construction : Fixing of Handle, knob, grips, levers and similar parts) |
- |
10 |
|
- |
| Cl.22.11 of
IS 302-1:2008(Construction : Fixing of non detachable part ) |
- |
10 |
|
- |
| Cl.22.7 of
IS 302-1:2008(Construction: adequate safeguards against the risk of excessive pressure) |
- |
10 |
|
- |
| Cl.22.6 of
IS 302-2-21:2018(Construction : Size of drain hole ) |
- |
10 |
|
- |
| Cl.22.6 of
IS 302-1:2008(Construction : Effect of water on 3 insulation ) |
- |
10 |
|
- |
| Cl.22.2 of
IS 302-1:2008(Construction : Provision to ensure all pole disconnection ) |
- |
10 |
|
- |
| Cl.22.1 of
IS 302-1:2008(Construction : IP test ) |
- |
10 |
|
- |
| Cl.21.2 of IS 302-1:2008(Mechanical strength : prevent penetration by sharp implements. ) |
- |
10 |
|
- |
| Cl.21.1 of IS 302-1:2008(Mechanical strength : Rough handling in normal use) |
- |
10 |
|
- |
| Cl.20 of IS 302-1:2008(Stability & Mechanical Hazards) |
- |
100 |
|
- |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : leakage from container during test) |
- |
50 |
|
- |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : High Voltage ) |
- |
50 |
|
- |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : Insulation of the supply cable or cord) |
- |
50 |
|
- |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : Wall ceiling temp. of test corner ) |
- |
50 |
|
- |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : emission of flame or molten metal or poisonous or ignitable gas ) |
- |
50 |
|
- |
| Cl.16 of IS 302-2-21-2018(Leakage current and Electric strength (After humidity): Electric Strentgh ) |
- |
100 |
|
- |
| Cl.16 of IS 302-2-21-2018(Leakage current and Electric strength (After humidity): Leakage current ) |
- |
100 |
|
- |
| Cl.15 of IS 302-2-21-2018(Moisture Resistance) |
- |
100 |
|
- |
| Cl.14 of IS 302-2-21:2018(Transient Over Voltages) |
- |
200 |
|
- |
| Cl.13 of IS 302-2-21:2018(3 Strength at Operating Temperature) |
- |
100 |
|
- |
| Cl.13 of IS 302-2-21:2018(Leakage Current ) |
- |
100 |
|
- |
| Cl.11 of 302-2-21:2018(Heating : Room Temp.) |
- |
50 |
|
- |
| Cl.11 of 302-2-21:2018(Heating : Temp of Rubber or PVC insulation of internal and external wiring) |
- |
50 |
|
- |
| Cl.11 of 302-2-21:2018(Heating : Temp of Walls, ceilings and floor of the test corner ) |
- |
50 |
|
- |
| Cl.10 of IS 302-2-21: 2018(Power Input & Current) |
- |
150 |
|
- |
| Cl.8 of IS 302-2-21:2018(Protection Against Access to Live Parts) |
- |
100 |
|
- |
| 7.101(Marking : Indifiction of water inlet and water outlet ) |
- |
10 |
|
- |
| 7.14(Marking : Legibility and durability) |
- |
10 |
|
- |
| 7.13(Marking : Official language of Instruction ) |
- |
10 |
|
- |
| 7.11(Marking : Indication of controls ) |
- |
10 |
|
- |
| 7.8(Marking : Terminals ) |
- |
10 |
|
- |
| 7.6(Marking : Symbol used ) |
- |
10 |
|
- |
| 7.1(Marking : Warning for Open- outlet ) |
- |
10 |
|
- |
| 7.1(Marking : Statement for pressure reducing valve ( For rated pressure less than 0.6 MPa)) |
- |
10 |
|
- |
| 7.1(Marking : Statement for a pressure-relief device) |
- |
10 |
|
- |
| 7.1(Marking : Rated capacity) |
- |
10 |
|
- |
| 7.1(Marking : Rated pressure) |
- |
10 |
|
- |
| 7.1(Marking : Country of manufacture) |
- |
10 |
|
- |
| 7.1(Marking: IP Number) |
- |
10 |
|
- |
| 7.1(Marking: Symbol for Class II) |
- |
10 |
|
- |
| 7.1(Marking: Model or type reference) |
- |
10 |
|
- |
| 7.1(Marking: Name, trademark or identification mark of manufacturer ) |
- |
10 |
|
- |
| 7.1(Marking : Rated power input) |
- |
10 |
|
- |
| 7.1(Marking : Symbol for nature of supply ) |
- |
10 |
|
- |
| 7.1(Marking : Rated Voltage ) |
- |
10 |
|
- |
| 15.4 (b)(Cold impact) |
- |
10 |
|
- |
|
- |
- REVISED VERSION
Included w.e.f.
26.04.2019 |
| 68 |
IS 302 : Part 2 : Sec 30 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 30 room heaters (First Revision) |
- |
3500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
50 |
|
Test |
| Cl.7.14 of IS302-1:2008(Marking and Instructions) |
- |
50 |
|
Test |
| Cl.7.14(Marking and Instructions) |
- |
50 |
|
Test |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
50 |
|
Test |
| Cl.8 & IS:302-1:2008(Protection Against Access to Live Parts) |
- |
100 |
|
Test |
| Cl.10 & IS:302-1:2008(Power Input and Current) |
- |
200 |
|
Test |
| Cl.11 & IS:302-1:2008(Heating) |
- |
200 |
|
Test |
| Cl.11.8(Heating) |
- |
100 |
|
Test |
| Cl.13 & IS:302-1:2008(Leakage Current & Electric Strength at operating temp. ) |
- |
200 |
|
Test |
| Cl.14 & IS:302-1:2008(Transient Over Voltages) |
- |
100 |
|
Test |
| Cl.15 & IS: 302-1:2008(Moisture Resistance
) |
- |
150 |
|
Test |
| Cl.15.3 of IS 302-1:200(Moisture Resistance
) |
- |
150 |
|
Test |
| Cl.16 & IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
200 |
|
Test |
| Cl.17 & IS:302-1:2008(Over load Protection of Transformers and Associated Circuits ) |
- |
100 |
|
Test |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
300 |
|
Test |
| Cl.20 & IS:302-1:2008(Stability & Mechanical Hazards) |
- |
100 |
|
Test |
| Cl.21 & IS:302-1:2008)(Mechanical Strength.) |
- |
100 |
|
Test |
| Cl.22.1 of IS 302-1:2008(Construction) |
- |
200 |
|
Test |
| Cl.23 & IS:302-1:2008(Internal Wiring
) |
- |
100 |
|
Test |
| Cl.24.1 of 302-1:2008(Component) |
- |
100 |
|
Test |
| Cl.25.1 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
200 |
|
Test |
| Cl.26.1 of IS 302-1:2008(Terminal for External Conductors
) |
- |
100 |
|
Test |
| Cl.27.1 of 302-1:2008(Provision for Earthing.) |
- |
100 |
|
Test |
| Cl.28 of 302-1:2008(Screws and Connections.) |
- |
100 |
|
Test |
| Cl.29 & IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation) |
- |
100 |
|
Test |
| Cl.30 & IS:302-1:2008(Resistance to Heat and Fire) |
- |
200 |
|
Test |
| Cl.31 & IS:302-1:2008(Resistance to Rusting.) |
- |
100 |
|
Test |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
- |
|
- |
| Cl.7.14 of IS302-1:2008(Marking and Instructions) |
- |
- |
|
- |
| Cl.7.14(Marking and Instructions) |
- |
- |
|
- |
| Cl.8 & IS:302-1:2008(Protection Against Access to Live Parts) |
- |
- |
|
- |
| Cl.10 & IS:302-1:2008(Power Input and Current) |
- |
- |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
- |
|
- |
| Cl.13 & IS:302-1:2008(Leakage Current & Electric Strength at operating temp. ) |
- |
- |
|
- |
| Cl.14 & IS:302-1:2008(Transient Over Voltages) |
- |
- |
|
- |
| Cl.15 & IS: 302-1:2008(Moisture Resistance
) |
- |
- |
|
- |
| Cl.16 & IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
- |
|
- |
| Cl.17 & IS:302-1:2008(Over load Protection of Transformers and Associated Circuits ) |
- |
- |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
- |
|
- |
| Cl.20 & IS:302-1:2008(Stability & Mechanical Hazards) |
- |
- |
|
- |
| Cl.21 & IS:302-1:2008)(Mechanical Strength.) |
- |
- |
|
- |
| Cl.22.1 of IS 302-1:2008(Construction) |
- |
- |
|
- |
| Cl.23 & IS:302-1:2008(Internal Wiring
) |
- |
- |
|
- |
| Cl.24.1 of 302-1:2008(Component) |
- |
- |
|
- |
| Cl.25.1 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
- |
|
- |
| Cl.26.1 of IS 302-1:2008(Terminal for External Conductors
) |
- |
- |
|
- |
| Cl.27.1 of 302-1:2008(Provision for Earthing.) |
- |
- |
|
- |
| Cl.28 of 302-1:2008(Screws and Connections.) |
- |
- |
|
- |
| Cl.29 & IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation) |
- |
- |
|
- |
| Cl.30 & IS:302-1:2008(Resistance to Heat and Fire) |
- |
- |
|
- |
| Cl.31 & IS:302-1:2008(Resistance to Rusting.) |
- |
- |
|
- |
|
- |
- Excluding: Cl 19.11.4.1 to 19.11.4.7 (EMI/EMC Tests), Component (Cl.24) |
| 69 |
IS 9968 : Part 1 (1988) |
Specification for elastomer insulatedcables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
1100 |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(TAPE : Proofed Tape) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 5.2(TAPE : 2 Polyethyl_ Terephthalate ( PETP ) Tape or
Plastic: Tape or Any Other SlIIitable Tape ) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 10( Conductor ) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 12.2(Insulation : Thickness of Insufatien) |
- |
100 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 18( Binder tape) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 19.2(Sheath : Thickness of Sheath) |
- |
100 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 20( Overall diameter) |
- |
100 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 21. (a)(Persulphate tests (for copper)) |
- |
500 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 21. (b)(Annealing Test (for coper)) |
- |
300 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 21. (c)( Tensile Test (for aluminium)) |
- |
200 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 21. (d)( Wrapping Test (for aluminium)) |
- |
160 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 21. (e)(Conductor Resistance ) |
- |
500 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 21.1( Tensile strength ) |
- |
350 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 22.1( Elongation) |
- |
350 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 21.1(type test : Ageing In air oven) |
- |
800 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 21.1(type test : Ageing in air bomb) |
- |
600 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 21.1(type test : Ageing In oxygen
bomb) |
- |
500 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 21.1(type test : Hot set elongation) |
- |
500 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 21.1(type test : Tear resistance ) |
- |
500 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 22.2(type test :Insulauon resistance High voltage (water immersron ) test) |
- |
500 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 22.2(type test : Flammability test
( applicable to cables
finished With SE 3 and
SE 4 sheaths only)
) |
- |
300 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 21(Water absorption test) |
- |
1500 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 3.1( Copper Cooduetor) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 3.2(Aluminium conductor) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 4.1(INSULATION : lnsulation for General Service) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 4.2(INSULATION : Heat Resisting insulation) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 4.3(INSULATION : Silicone Rubber Insulation) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 5.3(TAPE : Giass Tape) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 6.1(FILLERS : ) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 7.1(BRAID : Textile Braid) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 7.2(BRAID : Glass Braid ) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 8.1(SHEATH : General Service Insulated Cables and Flexible
Cords) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 8.2(SHEATH :Heat Resisting Insulated Cables) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 9.1(PresenRtive Compound) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 9.2(Varnish) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 11(Separator tape) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 12.4(Insulation : Allplication of Insulation) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 13(CORE IDENTiFICATlON) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 14(Tape) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 15(BRAIDING) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 16(COMPOUNDING AND VARNISHING) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 17(LAYING UP OF CORES) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 19.4( Sheath :Colour) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
| 23(identification) |
- |
20 |
|
Rs.10000/- for single core cable and Rs.1000/- for each additional core |
|
- |
- - |
| 70 |
IS 9857 (1990) |
Welding cables - Specification (First Revision) |
- |
9250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(SEPARATOR) |
- |
50 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 9.2(T h i c k n e s s o f C o v e r i n g) |
- |
750 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 10.1 a) 1)(Annealing test - IS 10810: Part 1) |
- |
900 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 10.1 a) 2)(Conductor resistance tes - IS 10810 : Part 5) |
- |
1200 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 10.1 c) 1)(Physical tests for
covering : Tensile strength ) |
- |
450 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 10.1 c) 1)(Physical tests for
covering : Elongation at break ) |
- |
450 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 10.1 c) 2)(Physical tests for
covering - Ageing in Air oven : Tensile strength variation) |
- |
500 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 10.1 c) 2)(Physical tests for
covering -Ageing in Air oven : Elongation at break ) |
- |
500 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 10.1 c) 2)(Physical tests for
covering - Ageing in Air oven : Tensile strength ) |
- |
500 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 10.1 c) 2)(Physical tests for
covering -Ageing in Air oven : Elongation variation at break ) |
- |
500 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 10.1 c) 3)(Physical tests for
covering - Ageing in Air Bomb : Tensile strength variation ) |
- |
400 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 10.1 c) 3)(Physical tests for
covering -Ageing in Air Bomb : Elongation variation at break ) |
- |
400 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 10.1 c) 4)(Physical tests for
covering - Oil Resistance : Tensile strength variation ) |
- |
250 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 10.1 c) 4)(Physical tests for
covering - Oil Resistance : Elongation variation at break ) |
- |
250 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 10.1 c) 5)(Hot set test ) |
- |
200 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 10.1 c) 5)(Permanent set ) |
- |
200 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 11.1(High Voltage Test ( Water Immersion
Test )) |
- |
1000 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 11.3(Static Flexibility Test) |
- |
900 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 11.4(Flammability Test) |
- |
600 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 4(Conductor : Material ) |
- |
50 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 6(COVERING) |
- |
50 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 7(CONDUCTOR : CONSTRUCTION ) |
- |
50 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 8(S E P A R A T O R) |
- |
50 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 9.1(C O V E R I N G : Application ) |
- |
50 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 9.3(T o l e r a n c e on Thickness o f C o v e r i n g) |
- |
350 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 9.4(A p p l i c a t i o n of C o v e r i n g) |
- |
50 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 9.5(Colour of C o v e r i n g) |
- |
50 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 11.2(Spark Test) |
- |
0 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 12.1(Manufacturer's Identification) |
- |
50 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 12.2(Cable Identification) |
- |
50 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 12.3(Cable Code) |
- |
50 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 13.1(Packing ) |
- |
50 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 13.2(Marking) |
- |
50 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 14(CABLE RATINGS) |
- |
50 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
| 15(VOLTAGE DROP) |
- |
250 |
|
Rs.7550/- for cable with SE1 Covering, Rs. 9250/- for cable with SE3 Covering cable, Rs.900/- extra for static flexibility test on Cu-conductor, Rs.900/- Separate wire before stranding. |
|
- |
- - |
| 71 |
IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
- |
45000 View breakup
Rs.29,000/- for Electronic games
(Video), Rs.45,000/- for Plasma/
LCD/LED TVs of screen size upto 66",
Rs.29,000/- for optical disc player with
built in amplifiers of input power 200W
and above, Rs.29,000/- for Amplifiers
with input power 2000W and above,
Rs.45,000/- for Electronic musical
system with input power 200W and
above, Rs.45,000/- for Power adopters
for audio, video & similar electronic
apparatus. ADDITIONAL PRODUCTED INCLUDED W.E.F.02-07-2020 -Rs.45,000/- for Television other than plasma / LCD / LED/ TV. Electronic Musical System with input power below 200W, Wireless Headphone & Earphone. ADDITIONAL PRODUCTS FOR PHASE V INCLUDED W.E.F. 05-11-2020: Rs.45000/- for Wireless microphone, video Camera, Webcam (finished product), Smart speakers (with and without display), Bluetooth speakers.
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking and instructions) |
- |
2000 |
|
Nil |
| 7(Heating under normal operating conditions) |
- |
8000 |
|
Nil |
| 8(Constructional requirements with regard to the protection against electric shock) |
- |
3000 |
|
Nil |
| 9(Electric shock hazard under normal operating conditions) |
- |
5000 |
|
Nil |
| 10(Insulation requirements) |
- |
3000 |
|
Nil |
| 11(Fault conditions) |
- |
5000 |
|
Nil |
| 12(Mechanical strength) |
- |
3000 |
|
Nil |
| 13(CLEARANCES and CREEPAGE DISTANCES) |
- |
3000 |
|
Nil |
| 15(TERMINALS) |
- |
2000 |
|
Nil |
| 16(External flexible cords) |
- |
2000 |
|
Nil |
| 19(Stability and mechanical hazards) |
- |
3000 |
|
Nil |
| 20(Resistance to fire) |
- |
3000 |
|
Nil |
| 17(Electrical connections and mechanical fixings) |
- |
2000 |
|
Nil |
| 14(Components) |
- |
1000 |
|
Nil |
|
- |
- REVISED VERSION IS
616:2017. Excluding: lonizing radiation test (CI.6.1), Laser radiation (C1.6.2), Requirements for insulated winding wires for use without additional interleaved insulation (C1.8.16), Endurance test for wound components with insulated winding wires without additional interleaved insulation (C1.8.17), Printed Boards(Cl.13.5), Component (Cl.14), Mechanical strength of picture tubes & Protection against the effect of implosion (Cl.18) |
| 72 |
IS 16103 : Part 1 (2012) |
Led modules for general lighting: Part 1 safety requirements |
- |
37500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
2000 |
|
NIL |
| 8(Terminals) |
- |
2000 |
|
NIL |
| 9(PROVISION FOR EARTHING) |
- |
2000 |
|
NIL |
| 10(Protection against accidental contact with live parts) |
- |
3000 |
|
NIL |
| 11(Mositure Resistance and Insulation) |
- |
5000 |
|
NIL |
| 12(Electric Strength) |
- |
3000 |
|
NIL |
| 13(Fault conditions) |
- |
5000 |
|
NIL |
| 15(Construction) |
- |
500 |
|
NIL |
| 16(Creepage distance and clearances) |
- |
2000 |
|
NIL |
| 17(Screws, current carrying parts and connections) |
- |
5000 |
|
NIL |
| 18(Resistance to heat, fire and tracking) |
- |
3000 |
|
NIL |
| 19(Resistance to corrosion) |
- |
4000 |
|
NIL |
| 21(Heat management) |
- |
1000 |
|
NIL |
|
- |
- Included w.e.f. 02-07-2020. |
| 73 |
IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
1100 V |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1(CONSTRUCTION : CONDUCTOR) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring , Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 9.2(INSULATION : Thickness of Insulation) |
- |
50 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 11.1(LAYING UP OF CORES) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 12.3(INNER SHEATH :Thickness of Inner Sheath) |
- |
50 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 13.1.2(Armouring: Coverage ) |
- |
300 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 13.3(Armouring : Dimensions -Formed wire ) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 13.5.2(ARMOURING : Resistance) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 13.6 g)(ARMOURING: Resistivity) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 14.4.1(Thickness of Outer Sheath : Unarmowed Cables) |
- |
50 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 14.4.2(Thickness of Outer Sheath : Armoured Cables) |
- |
50 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 a) 1)(Tests on conductor : Annealing test ( for copper )) |
- |
150 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
150 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
150 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)1)(Phyaical tests for insulation : Tensile Test) |
- |
250 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)1)(Phyaical tests for insulation : Elongation ) |
- |
250 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)1)(Physical tests for sheath : Elongation ) |
- |
250 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
250 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
400 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
400 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)3)(Phyaical tests for insulation : Shrinkage ) |
- |
50 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
50 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)3)(Phyaical tests for Sheath : Shrinkage ) |
- |
50 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
50 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)4)(Hot deformation : Insulation ) |
- |
200 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)4)(Hot deformation : Sheath ) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)5)( Loss of mass in air oven- Insulation ) |
- |
400 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)5)( Loss of mass in air oven- sheath ) |
- |
400 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)6)(Heat shock test- Insulation ) |
- |
50 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)6)(Heat shock test- sheath ) |
- |
50 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)7)(Thermal stability- insulation ) |
- |
50 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
200 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 e)(Insulation resistance test : IR Constant ) |
- |
200 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 f)(High voltage test ( water immersion test )) |
- |
250 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 g)(High voltage test at room temperature) |
- |
250 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.4 a)(Cold bend test- Insulation ( Optional test)) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.4 a)(Cold bend test- Sheath ( Optional test)) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.4 b)(Cold impact test- Insulation ( Optional test)) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.4 b)(Cold impact test- Sheath ( Optional test)) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 16.4(Flammability Test) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 3.1(MATERIALS : CONDUCTOR) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 4.1.1(INSULATION : General Purjose Insulaiion) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 4.1.2(INSULATION : Heat Resisting Insulation) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 5.1(MATERIALS : FILLER AND INNER SHEATH) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 5.2(MATERIALS : FILLER AND INNER SHEATH) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 6.1(MATERIALS : ARMGURING) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 6.2(MATERIALS : ARMGURING) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 7.1.1(OUTER SHEATH : For Cables with General Purpose InsuIafion) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 7.1.2(OUTER SHEATH : For Cables with Heat Resisting InsuIalion) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 8.2(CONSTRUCTION : CONDUCTOR) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 9.1(INSULATION ) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 9.3(INSULATION :Tolerance on Thickness of Insulation) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 9.4(INSULATION : Application of Insulation) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 10.1(CORE IDENTIFICATION) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 10.2(CORE IDENTIFICATION) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 10.3(CORE IDENTIFICATION) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 10.3.1(Arrangement of Marking) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 11.2(LAYING UP OF CORES) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 12.1(INNER SHEATH) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 12.2(INNER SHEATH) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 12.3.1(INNER SHEATH :Thickness of Inner Sheath) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 13.1.1(ARMOURING : Application) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 13.1.3(ARMOURING : Direction of lay ) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 13.1.4(ARMOURING : Application) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 13.2(ARMOURING : Type of Armour) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 13.2.1(ARMOURING : Type of Armour) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 13.3(Armouring : Dimensions -Wire Diameter) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 13.4(ARMOURING : Joints) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 13.5.1(ARMOURING : Resistance) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 13.6 b)(ARMOURING: Elongation ) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 14.1(OUTER SHEATH) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 14.2(OUTER SHEATH) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 14.3(OUTER SHEATH : Colour ) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 a) 3)(Tests on conductor : Wrapping test ( for aluminium )) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 a) 4)(Tests on conductor : Conductor resistance test) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 a) 4)(Resistance test - Neutral conductor ) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)1)(Physical tests for sheath : Tensile stregth ) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
400 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
400 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
400 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
400 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
400 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 d)7)(Thermal stability- Sheath ) |
- |
100 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1 g)(High voltage test at room temperature) |
- |
220 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.4 c)(Armour resistance test ( for other than mining cables ).- Optional test ) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 16.1(DETAILS OF TESTS : General) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 16.2(DETAILS OF TESTS : High Voltage Test at Room Temperature) |
- |
0 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 16.3.1(High Voltage Test ( Water Immersion Test ) : a.c. Test) |
- |
500 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 16.3.2(High Voltage Test ( Water Immersion Test ) : d.c. Test) |
- |
850 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 16.5(Oxygen Index Test) |
- |
1500 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 16.6(Flame Retardance Test on Single Cables) |
- |
2000 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 16.7(Flame Retardance Test on Bunched Cables) |
- |
3500 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 16.9(Test for Halogen Acid Gas Evolution) |
- |
1000 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 16.1(Temperature Index) |
- |
2000 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 17.1(IDENTIFICATION : Manufacturer’s Identification) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 17.2(IDENTIFICATION : Cable Identification) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 17.2.1(IDENTIFICATION : Cable Identification) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 17.3(IDENTIFICATION : Cable Code) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1.e(Insulation resistance Test- Insulation resistance At Maximum rated temperature temperature) |
- |
200 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1.e(Insulation resistance Test- Insulation resistance constant At Room temperature) |
- |
200 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1.e(Insulation resistance Test- Volume Resistivity At Maximum rated temperature temperature) |
- |
200 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 15.1.e(Insulation resistance Test- Volume Resistivity At Room temperature) |
- |
200 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 16.4(Flammability Test- Un affected portion) |
- |
50 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 16.4(Flammability Test- Period of Burning) |
- |
50 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 9.3(Minimum Thickness of Reduce core insulation) |
- |
50 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 9.2(Thickness of Reduce core insulation) |
- |
50 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
| 3.1 Table 2
IS 8130(Number of wires in the conductor) |
- |
10 |
|
Rs.6000/- for single core cable and Rs.1000/- for each additional core, Rs.1000/- for armouring, Rs.9000/- additional for FR and Rs.12000/- additional for FRLSH. |
|
- |
- (C-1 & C-2 category included w.e.f. 23.02.2024) |
| 74 |
IS 16046 : Part 1 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 1 Nickel Systems ( Second Revision ) |
- |
80000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2(Insulation and Wiring) |
- |
2000 |
|
NIL |
| 6(Tyoe Test amd Sample Size) |
- |
1500 |
|
Nil |
| 7.1(Charging procedure for test purposes) |
- |
10500 |
|
Nil |
| 7.2(Intended Use) |
- |
11000 |
|
Nil |
| 7.3(Reasonably foreseeable misuse) |
- |
11000 |
|
Nil |
| 8.2(Small Cell and battery safety information) |
- |
10000 |
|
Nil |
| 4(Parameter Measurement Tolerances) |
- |
1000 |
|
Nil |
| 5(General Safety Considerations) |
- |
2000 |
|
Nil |
| 5.1(General) |
- |
2000 |
|
Nil |
| 5.3(Venting) |
- |
2000 |
|
Nil |
| 5.4(Temperature, Voltage and Current Management) |
- |
2000 |
|
Nil |
| 5.5(Terminal Contacts) |
- |
2000 |
|
Nil |
| 5.6(Assembly of Cells into batteries) |
- |
2000 |
|
Nil |
| 5.7(Quality Plan) |
- |
2000 |
|
Nil |
| 8(Information for safety) |
- |
2000 |
|
Nil |
| 8.1(General) |
- |
2000 |
|
Nil |
| 9(Marking) |
- |
2000 |
|
Nil |
| 9.1(Cell Marking) |
- |
2000 |
|
Nil |
| 9.2(Battery Marking) |
- |
2000 |
|
Nil |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
2000 |
|
Nil |
| 9.4(Other information) |
- |
2000 |
|
Nil |
| 10(Packaging) |
- |
2000 |
|
Nil |
| 7(Specific requirements and tests) |
- |
3000 |
|
Nil |
|
- |
- REVISED VERSION
Included w.e.f.
28.11.2018. |
| 75 |
IS 10322 : Part 5 : Sec 8 (2013) |
Luminaires: Part 5 particular requirements: Sec 8 emergency lighting |
- |
75000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Marking) |
- |
2000 |
|
n/a |
| 7.0(Construction) |
- |
7000 |
|
n/a |
| 8.0(Creepage Distance and Clearances) |
- |
4000 |
|
n/a |
| 9.0(Provision for earthing) |
- |
2000 |
|
n/a |
| 10.0(Terminals) |
- |
5000 |
|
n/a |
| 11.0(External & Internal Wiring) |
- |
4000 |
|
n/a |
| 12.0(Protection against electric shock) |
- |
8000 |
|
n/a |
| 13.0(Endurance Tests and Thermal Tests) |
- |
8000 |
|
n/a |
| 14.0(Resistance to Dust & Moisture) |
- |
6000 |
|
n/a |
| 15.0(Insulation Resistance and Electric Strength) |
- |
2000 |
|
n/a |
| 16.0(Resistance to Heat , fire and tracking) |
- |
4000 |
|
n/a |
| 17.0(Functional Safety) |
- |
3000 |
|
n/a |
| 18.0(Changeover Operation) |
- |
4000 |
|
n/a |
| 19.0(High Temperature Operation) |
- |
4000 |
|
n/a |
| 20.0(BATTERY CHARGERS FOR SELFCONTAINED EMERGENCY LUMINAIRES) |
- |
4000 |
|
n/a |
| 21.0(TEST DEVICES FOR EMERGENCY OPERATION) |
- |
4000 |
|
n/a |
| 22.0(REST MODE AND INIHIBITION MODE FACILITIES) |
- |
2000 |
|
n/a |
| 4(General Test Requireements) |
- |
1000 |
|
n/a |
| 5(Classification of Luminaires') |
- |
1000 |
|
n/a |
|
- |
- Included w.e.f.
28.11.2018. |
| 76 |
IS 10322 : Part 5 : Sec 7 (2017) |
Luminaires: Part 5 particular requirements: Sec 7 lighting chains (First Revision) |
- |
75000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 20.6(Marking) |
- |
2000 |
|
n/a |
| 20.7(Construction) |
- |
10000 |
|
n/a |
| 20.8(Creepage Distance and Clearances) |
- |
8000 |
|
n/a |
| 20.10(Terminals) |
- |
10000 |
|
n/a |
| 20.11(External & Internal Wiring) |
- |
8000 |
|
n/a |
| 20.12(Protection against electric shock) |
- |
8000 |
|
n/a |
| 20.13(Endurance Tests and Thermal Tests) |
- |
10000 |
|
n/a |
| 20.14(Resistance to Dust & Moisture) |
- |
8000 |
|
n/a |
| 20.15(Insulation Resistance and Electric Strength) |
- |
5000 |
|
n/a |
| 20.16(Resistance to Heat , fire and tracking) |
- |
4000 |
|
n/a |
| 20.4(General Test Requireements) |
- |
1000 |
|
n/a |
| 20.5(Classification of Luminaires') |
- |
1000 |
|
n/a |
|
- |
- REVISED VERSION OF 2017 INCLUDED w.e.f. 17.04.2018 |
| 77 |
IS 10322 : Part 5 : Sec 6 (2013) |
Luminaires: Part 5 particular requirements: Sec 6 handlamps |
- |
75000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Marking) |
- |
2000 |
|
n/a |
| 7.0(Construction) |
- |
10000 |
|
n/a |
| 8.0(Creepage Distance and Clearances) |
- |
8000 |
|
n/a |
| 9.0(Provision for earthing) |
- |
6000 |
|
n/a |
| 10.0(Terminals) |
- |
8000 |
|
n/a |
| 11.0(External & Internal Wiring) |
- |
6000 |
|
n/a |
| 12.0(Protection against electric shock) |
- |
8000 |
|
n/a |
| 13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
n/a |
| 14.0(Resistance to Dust & Moisture) |
- |
8000 |
|
n/a |
| 15.0(Insulation Resistance and Electric Strength) |
- |
3000 |
|
n/a |
| 16.0(Resistance to Heat , fire and tracking) |
- |
4000 |
|
n/a |
| 4(General Test Requireements) |
- |
1000 |
|
n/a |
| 5(Classification of Luminaires') |
- |
500 |
|
n/a |
| 8.2(Packing -Each Package shall bear the following Particulars) |
- |
500 |
|
n/a |
|
- |
- - |
| 78 |
IS 10322 : Part 5 : Sec 5 (2013) |
Luminaires: Part 5 particular requirements: Sec 5 floodlights (First Revision) |
- |
75000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Marking) |
- |
2000 |
|
n/a |
| 7.0(Construction) |
- |
8000 |
|
n/a |
| 8.0(Creepage Distance and Clearances) |
- |
5000 |
|
n/a |
| 9.0(Provision for earthing) |
- |
5000 |
|
n/a |
| 10.0(Terminals) |
- |
5000 |
|
n/a |
| 11.0(External & Internal Wiring) |
- |
5000 |
|
n/a |
| 12.0(Protection against electric shock) |
- |
5000 |
|
n/a |
| 13.0(Endurance Tests and Thermal Tests) |
- |
8000 |
|
n/a |
| 14.0(Resistance to Dust & Moisture) |
- |
8000 |
|
n/a |
| 15.0(Insulation Resistance and Electric Strength) |
- |
5000 |
|
n/a |
| 16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
n/a |
| 17.0(Photometric Test) |
- |
12000 |
|
n/a |
| 4(General Test Requireements) |
- |
1000 |
|
n/a |
| 5(Classification of Luminaires') |
- |
1000 |
|
n/a |
|
- |
- For rated voltage up to 300V. |
| 79 |
IS 10322 : PART 5 : SEC 3 (2012) |
Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) |
- |
75000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Marking) |
- |
2000 |
|
n/a |
| 7.0(Construction) |
- |
8000 |
|
n/a |
| 8.0(Creepage Distance and Clearances) |
- |
5000 |
|
n/a |
| 9.0(Provision for earthing) |
- |
5000 |
|
n/a |
| 10.0(Terminals) |
- |
5000 |
|
n/a |
| 11.0(External & Internal Wiring) |
- |
5000 |
|
n/a |
| 12.0(Protection against electric shock) |
- |
5000 |
|
n/a |
| 13.0(Endurance Tests and Thermal Tests) |
- |
8000 |
|
n/a |
| 14.0(Resistance to Dust & Moisture) |
- |
8000 |
|
n/a |
| 15.0(Insulation Resistance and Electric Strength) |
- |
5000 |
|
n/a |
| 16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
n/a |
| 17.0(Photometric Test) |
- |
12000 |
|
n/a |
| 4(General Test Requireements) |
- |
1000 |
|
n/a |
| 5(Classification of Luminaires') |
- |
1000 |
|
n/a |
|
- |
- For rated voltage up to 300V. |
| 80 |
IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
1100V |
9000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 11.2(Legibility) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 11.1(Durability) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 10.9(Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
1250 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 10.4(Flammability test- Unaffected portion) |
- |
100 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| table 1 e) 3) (IR constant- max. Temp) |
- |
250 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 10.2(HV (room temperature)) |
- |
300 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 10.1(HV (water immersion)) |
- |
600 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 10.8(Smoke density rating) |
- |
3000 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 10.6(Halogen evolution) |
- |
2000 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 10.7(Temperature index) |
- |
2500 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 10.5(Oxygen index) |
- |
2500 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) d) 9)(Cold impact for sheath) |
- |
100 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) d) 8)(Cold bend for sheath) |
- |
100 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) c) 9)(Cold impact for insulation) |
- |
100 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) c) 8)(Cold bend for insulation) |
- |
100 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) d) 7)(Thermal stability- Sheath ) |
- |
125 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) c) 7)(Thermal stability- Insulation ) |
- |
125 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) d) 6)(Hot deformation -Indentation depth - Sheath ) |
- |
140 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) c) 6)(Hot deformation - Indentation depth- Insulation) |
- |
140 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) d) 5)(Heat shock-Sheath ) |
- |
100 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) c) 5)(Heat shock-Insulation ) |
- |
100 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) c) 4)(Shrinkage-Insulation) |
- |
100 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) d) 2)(Loss of mass- Sheath ) |
- |
400 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) c) 2)(Loss of mass- Insulation ) |
- |
400 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) d) 3)(Sheath- Elongation variation) |
- |
300 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) d) 3)(Sheath- TS variation) |
- |
300 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) d) 3)(Sheath- Elongation (After ageing)) |
- |
300 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) d) 3)(Sheath- Tensile strength (After ageing)) |
- |
300 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) d) 1)(Sheath- Elongation (Without ageing)) |
- |
300 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) d) 1)(Sheath -Tensile strength (Without ageing)) |
- |
100 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 8.3(Thickness of Sheath) |
- |
50 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 5.3(Thickness of Insulation) |
- |
50 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 9.1(Ovality) |
- |
50 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 9(Overall dimensions) |
- |
50 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 10.11(Per sulphate test (for tinned Cu cable only)) |
- |
350 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 4.2(Conductor resistance test) |
- |
250 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 4.1(Wrapping test (for Al)) |
- |
50 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 4.1(Tensile test (for Al)- After Stranding) |
- |
50 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 4.1(Tensile test (for Al)-Before Stranding) |
- |
50 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 4.1(Annealing test (for copper)) |
- |
100 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| (Cl.16.1)
(Cl.19.1)(Conductor- Diameter ) |
- |
50 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 4.1(Conductor - Material) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 13(Cable code) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 11(Identification) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 10.4(Flammability test-Burning after flame removal) |
- |
100 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| table 1 e) 3) (IR constant- Room temp ) |
- |
250 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
250 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| table 1 e) 3) (Volume Resistivity - Room temp ) |
- |
250 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 10.1(HV (water immersion)) |
- |
300 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1(Category Code) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) d) 4)(Cracks Observed) |
- |
20 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) d) 4)(Shrinkage- Sheath ) |
- |
100 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) c) 4)(Cracks Observed) |
- |
50 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) c) 3)(Elongation (After ageing)) |
- |
300 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) c) 3)(Tensile strength (After ageing)) |
- |
300 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) c) 3)(Elongation variation) |
- |
300 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) c) 3)(TS variation) |
- |
300 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) c) 1)(Elongation (Without ageing)) |
- |
300 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 1 iii) c) 1)(Tensile strength (Without ageing)) |
- |
100 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| (Cl. 18.1.4)
(Cl. 19.1.5)
(Cl. 20.1.4)
(Cl. 22.1.4)(Colour of Sheath) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 5.2(Application ) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| (Cl.6.1.3 of IS 8130:2013)(Flexible Conductors (Classes 5)) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| (Cl.6.1.3 of IS 8130:2013)( Flexible Conductors (Classes 5)) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| (Cl.6.1.3 of IS 8130:2013)(Stranded circular non compacted conductors(Class-2)) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| (Cl.6.1.3 of IS 8130:2013)(Stranded compacted circular conductors and shaped conductors (Class 2)) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| (Cl.6.1.3 of IS 8130:2013)(Stranded circular non compacted conductors (Class-2)) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| (Cl.6.1.3 of IS 8130:2013)(Stranded circular non compacted conductors (Class-2)) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| (Cl.6.1.3 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| (Cl.6.1 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| (Cl.6.1 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| (Cl.16.1)
(Cl.19.1)(Conductor) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| (Cl.16.1)
(Cl.19.1)(Conductor) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| (Cl.16.1)
(Cl.19.1)(Conductor) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| (Cl. 18.1.3)
(Cl. 19.1.4)
(Cl. 20.1.3)
(Cl. 21.1.3)
(Cl. 22.1.3)(Assembly of cores ) |
- |
20 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 12(CONSTRUCTION Core Identification) |
- |
20 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 8.1(Sheath Material ) |
- |
20 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 7(Binder Tape) |
- |
20 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 6.2(Filler) |
- |
20 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 6.1(Filler) |
- |
20 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 5.1(Insulation) |
- |
20 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 4.4(Joints in Conductor) |
- |
20 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 4.4(Joints in Conductor) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 4.1(Conductor - Material) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 10.11(Persulphate Test ) |
- |
200 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 12.0(Core identification) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 4, IS 8130(Construction of conductor) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| Table 2, IS 8130(No fo wire in a conductor) |
- |
10 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 8.3(Minimum thickness of Sheath) |
- |
50 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
| 5.3(Avarage thickness of insulation) |
- |
50 |
|
Rs.9000/- for single core cable and Rs.1000/- for each additional core, Rs.5000/- additional for FR and Rs.10000/- additional for FRLSH. |
|
- |
- - |
| 81 |
IS 10322 : Part 5 : Sec 2 (2012) |
Luminaires: Part 5 particular requirements: Sec 2 recessed luminaires (First Revision) |
- |
75000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Marking) |
- |
2000 |
|
n/a |
| 7(Construction) |
- |
8000 |
|
n/a |
| 8(Creepage Distance and Clearances) |
- |
5000 |
|
n/a |
| 9(Provision for earthing) |
- |
5000 |
|
n/a |
| 10(Terminals) |
- |
5000 |
|
n/a |
| 11(External & Internal Wiring) |
- |
5000 |
|
n/a |
| 12(Protection against electric shock) |
- |
5000 |
|
n/a |
| 13(Endurance Tests and Thermal Tests) |
- |
8000 |
|
n/a |
| 14(Resistance to Dust and Moisture) |
- |
8000 |
|
n/a |
| 15(Insulation Resistance and Electric Strength) |
- |
5000 |
|
n/a |
| 16(Resistance to Heat , fire and tracking) |
- |
5000 |
|
n/a |
| 17(Photometric Test) |
- |
13000 |
|
n/a |
| 4(General Test Requireements) |
- |
500 |
|
n/a |
| 5(Classification of Luminaires') |
- |
500 |
|
n/a |
|
- |
- For rated voltage up to 300V. |
| 82 |
IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
- |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
2000 |
|
Nil |
| 8(Protection against accidental contact with live parts) |
- |
4000 |
|
Nil |
| 9(Terminals) |
- |
5000 |
|
Nil |
| 10(PROVISION FOR EARTHING) |
- |
2000 |
|
Nil |
| 11(MOISTURE RESISTANCE) |
- |
6000 |
|
Nil |
| 12(Electric Strength) |
- |
2000 |
|
Nil |
| 14(Fault conditions) |
- |
4000 |
|
Nil |
| 15(Transformer heating) |
- |
5000 |
|
Nil |
| 16(Construction) |
- |
2000 |
|
Nil |
| 17(Creepage distance and clearances) |
- |
2000 |
|
Nil |
| 18(Screws, current carrying parts and connections) |
- |
3000 |
|
Nil |
| 19(Resistance to heat, fire and tracking) |
- |
5000 |
|
Nil |
| 20(Resistance to corrosion) |
- |
2000 |
|
Nil |
| 13(Thermal endurance test for winding of ballasts) |
- |
1000 |
|
Nil |
|
- |
- Excluding:
Components: Enclosure, bridging resistor in primary circuit capacitor and RC units, RF suppression (X-Y capacitors)inductor, MOVR/VDRSMPS/Mains transformer, PCB material, Metal base PCB for LED, Transparent cover bobbin, Insulated tape, Heat shrinkage sleeve, Connector, Fuse, internal wire LED, Optocoupler, EMI/EMC filter, Winding wire, Thin sheet material |
| 83 |
IS 9537 : Part 3 (1983) |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
- |
4950 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Marking) |
- |
50 |
|
Inspection |
| 6.2(Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
50 |
|
Test |
| 7.1.1(Maximum and minimum outside diameter of socket) |
- |
50 |
|
Test |
| 7.1.1 Table-2(Length of Socket end) |
- |
50 |
|
Test |
| 7.1.2(Maximum and minimum outside diameter of conduit) |
- |
50 |
|
Test |
| 7.2(Minimum inside diameter of conduit) |
- |
100 |
|
Test |
| 7.3(Length of conduit) |
- |
100 |
|
Test |
| 7.4(Unifomity of The wall Thickness) |
- |
150 |
|
Test |
| 9.2(Bending Test i) At Room Temp ii) At Low Temp (-5 ±2°C)) |
- |
400 |
|
Test |
| 9.3(Compression Test as per caluse 9.3 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
Test |
| 9.4(Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
1500 |
|
Test |
| 9.5(Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
300 |
|
Test |
| 10(Resistance to Heat -Ball presure test) |
- |
250 |
|
Test |
| 11(Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
250 |
|
Test |
| 12(Electrical Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
600 |
|
Test |
| 12(Electrical Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
Test |
| 13(Tests for external influence as per clause 13 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
Test |
| 6.3(Standard Mark on Conduit) |
- |
0 |
|
Test |
| 8.1(Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
Test |
| 12(3 Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
200 |
|
Test |
| 12(3 Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
200 |
|
Test |
| 13(Tests for external influence as per clause 13 of IS: 9537 (Part 1)-1980) |
- |
50 |
|
Test |
| 11.0(Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
Test |
| 10.0(Resistance to Heat -Ball presure test) |
- |
100 |
|
Test |
| 9.5 Fig.5(Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
Test |
| 9.4(Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
Test |
| 9.3(Compression Test (after removal of force) as per caluse 9.3.3 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
Test |
| 9.3(Compression Test at Full force applied (On load)) |
- |
0 |
|
Test |
| 9.2(Bending Test At Low Temp (-5 ±2°C)) |
- |
0 |
|
Test |
| 9.2(Bending Test At Room Temp) |
- |
0 |
|
Test |
| 8.1(Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
Test |
| 7.4(Unifomity of The wall Thickness) |
- |
0 |
|
Test |
| 7.3(Length of conduit) |
- |
0 |
|
Test |
| 7.2 Fig.3(Minimum inside diameter of conduit) |
- |
0 |
|
Test |
| 7.1.2 Fig.2(Minimum outside diameter of conduit) |
- |
0 |
|
Test |
| 7.1.2 Fig.1(Maximum outside diameter of conduit) |
- |
0 |
|
Test |
| 7.1.1 Table-2(Length of Socket end) |
- |
0 |
|
Test |
| 7.1.1 Fig.8(Maximum inside diameter of socket) |
- |
0 |
|
Test |
| 7.1.1 Fig.7(Maximum outside diameter of socket) |
- |
0 |
|
Test |
| 6.3(Standard Mark on Conduit) |
- |
0 |
|
Test |
| 6.2(Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
Test |
| 6.1 - d(Marking) |
- |
0 |
|
Test |
| 6.1 - c(Marking) |
- |
0 |
|
Test |
| 6.1 - b(Marking) |
- |
0 |
|
Test |
| 6.1 - a(Marking) |
- |
0 |
|
Test |
|
- |
- - |
| 84 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
45000 View breakup
Rs. 45,000/- for Self-Ballasted LED Lamps for General lighting services: Safety Requirements. [5% discount to BIS]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
2000 |
|
n/a |
| 6(Interchangeability) |
- |
8000 |
|
n/a |
| 7(Protection against accidental contact with live parts) |
- |
5000 |
|
n/a |
| 8(Insulation Resistance and Electric Strength) |
- |
5000 |
|
n/a |
| 9(MECHANICAL STRENGTH) |
- |
4000 |
|
n/a |
| 10(cap temperature) |
- |
5000 |
|
n/a |
| 11(Resistance to Heat) |
- |
4000 |
|
n/a |
| 12(Resistance to Flame and Ignition) |
- |
5000 |
|
n/a |
| 13(Fault conditions) |
- |
5000 |
|
n/a |
| 14(Creepage distance and clearances) |
- |
2000 |
|
n/a |
|
- |
- Restricted to cap type B22d, E14 and E27 only. |
| 85 |
IS 302 : Part 2 : Sec 203 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 203 electric call bells and buzzers for indoor use |
- |
22000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Rating) |
- |
50 |
|
- |
| 6(Classification) |
- |
50 |
|
- |
| 7(Marking) |
- |
500 |
|
- |
| 8(Protection against Access to Live Parts) |
- |
500 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 10("Power Input
& Current") |
- |
1000 |
|
- |
| 11(Temperature Rise/ Heating) |
- |
1300 |
|
- |
| 12(Operation Under Overload Conditions of Appliances with heating Element) |
- |
0 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
1500 |
|
- |
| 14("Radio and Television Interference Suppression / Transient Over Voltage
") |
- |
1000 |
|
- |
| 15(Moisture Resistance) |
- |
1300 |
|
- |
| 16(Leakage Current and Electric Strength/ Insulation Resistance and Electric Strength (After Humidity treatment)) |
- |
2000 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
1000 |
|
- |
| 22(Construction) |
- |
1000 |
|
- |
| 23(Internal Wiring) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 25(Supply Connection & External Flexible Cords) |
- |
1000 |
|
- |
| 26(Terminals For External Conductors) |
- |
1000 |
|
- |
| 27(Provision For Earthing) |
- |
1000 |
|
- |
| 28(Screws & Connections) |
- |
1000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
1000 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
1800 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 32(Radiation hazards) |
- |
1000 |
|
- |
|
- |
- Included .w.e.f.11.02.2025
Exclusion
Cl 24.1.1, 24.1.2 & 24.1.5 (Components)
Cl 19.11.4.1 to 19.11.4.7 (EMI/EMC) |
| 86 |
IS 302 : Part 2 : Sec 2 (1997) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 2 vacuum cleaners and water suction cleaning appliances |
- |
27000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Rating) |
- |
50 |
|
- |
| 6(Classification) |
- |
50 |
|
- |
| 7(Marking) |
- |
1000 |
|
- |
| 8(Protection against Access to Live Parts) |
- |
1000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
500 |
|
- |
| 10("Power Input
& Current") |
- |
1000 |
|
- |
| 11(Temperature Rise/ Heating) |
- |
1800 |
|
- |
| 12(OPERATION UNDER OVERLOAD
CONDITIONS OF APPLIANCES WITH
HEATING ELEMENTS) |
- |
0 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE) |
- |
1500 |
|
- |
| 14(RADIO AND TELEVISION
INTERFERENCE SUPPRESSION) |
- |
1000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
1800 |
|
- |
| 16(INSULATION RESISTANCE AND
ELECTRIC STRENGTH ( AFTER HUMIDITY
TREATMENT )) |
- |
1500 |
|
- |
| 17(OVERLOAD PROTECTION) |
- |
1000 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
1500 |
|
- |
| 20(STABILITY AND MECHANICAL
HAZARDS) |
- |
1000 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
| 22(Construction) |
- |
1000 |
|
- |
| 23(INTERNAL WIRING) |
- |
1000 |
|
- |
| 24(COMPONENTS) |
- |
1000 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL
FLEXIBLE CABLES AND CORDS) |
- |
1000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
1000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
- |
| 29(CREEPAGE DISTANCES, CLEARANCES
AND DISTANCES THROUGH INSULATION) |
- |
1000 |
|
- |
| 30(RESISTANCE TO HEAT, FIRE AND
TRACKING) |
- |
1800 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
- |
| 32(RADIATION HAZARDS) |
- |
1000 |
|
- |
|
- |
- Included w.e.f. 24.12.2024. Excluding Cl 19.11.4.1 to 19.11.4.7 (EMI/EMC Tests), Cl 24.1.1, 24.1.2 & 24.1.5 (Components). |
| 87 |
IS 16333 : Part 3 (2022) |
Mobile phone handsets: Part 3 Indian language support for mobile phone handsets - Specific requirements(Second Revision) |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Inputting of text) |
- |
9000 |
|
- |
| 5.2(Message Readability) |
- |
9000 |
|
- |
| 6(Marking) |
- |
2000 |
|
- |
| "Cl.6.1 "(Marking) |
- |
2000 |
|
- |
| "Cl.6.2 "(BIS Certification Marking) |
- |
1000 |
|
- |
| 4(Requirements) |
- |
0 |
|
- |
| 5(Tests) |
- |
18000 |
|
- |
| 6(Marking) |
- |
2000 |
|
- |
|
- |
- Included w.e.f 19.08.2024 |
| 88 |
IS 16169 (2014) |
Utility - Interconnected photovoltaic inverters - Test procedure of islanding prevention measures |
- |
157000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7, (Elec)(Documentation) |
- |
3000 |
|
- |
| 6 to 6.2, (Elec)(Test for single or multi-phase inverter to Pass/fail criteria) |
- |
5000 |
|
- |
| Annex A, (Elec)(Islanding as it applies to PV systems) |
- |
1000 |
|
- |
| Annex B, (Elec)(Test for independent islanding device) |
- |
1000 |
|
- |
| 6, (Elec)(Test for single or multi-phase inverter) |
- |
145000 |
|
- |
| 7(Documentation) |
- |
3000 |
|
- |
| 6 to 6.2(Test for single or multi-phase inverter to Pass/fail criteria) |
- |
5000 |
|
- |
| Annex A(Islanding as it applies to PV systems) |
- |
1000 |
|
- |
| Annex B(Test for independent islanding device) |
- |
1000 |
|
- |
| 6(Test for single or multi-phase inverter) |
- |
145000 |
|
- |
|
- |
- Included w.e.f 16.07.2024 |
| 89 |
IS 16614 : Part 2 (2022) |
Double-Capped LED Linear Lamps Part 2 Performance Specification |
- |
195000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Requirements on Tests) |
- |
1000 |
|
- |
| 5(Marking) |
- |
3000 |
|
- |
| 6(Dimensions) |
- |
4000 |
|
- |
| 7.1(General Test Conditions) |
- |
1000 |
|
- |
| 7.2(Creation of LED Lamp Families to reduce test effort) |
- |
1000 |
|
- |
| 8.1(Lamp Power) |
- |
3000 |
|
- |
| 8.2(Power Factor) |
- |
1000 |
|
- |
| 8.3(Harmonics) |
- |
4000 |
|
- |
| 9.1(Luminous Flux) |
- |
5000 |
|
- |
| 9.2(Luminous intensity distribution, peak intensity and beam angle) |
- |
5000 |
|
- |
| 9.3(Luminous Efficacy) |
- |
5000 |
|
- |
| 10(COLORIMETRIC CHARACTERISTICS) |
- |
5000 |
|
- |
| 11(Lamp Life) |
- |
155000 |
|
- |
| 12(Dimming) |
- |
0 |
|
- |
| 14.1(Type Tests) |
- |
1000 |
|
- |
| 14.2(Acceptance Tests) |
- |
1000 |
|
- |
| 4(General Requirements on Tests) |
- |
1000 |
|
- |
| 5(Marking) |
- |
3000 |
|
- |
| 6(Dimensions) |
- |
4000 |
|
- |
| 7.1(General Test Conditions) |
- |
1000 |
|
- |
| 7.2(Creation of LED Lamp Families to reduce test effort) |
- |
1000 |
|
- |
| 8.1(Lamp Power) |
- |
3000 |
|
- |
| 8.2(Power Factor) |
- |
1000 |
|
- |
| 8.3(Harmonics) |
- |
4000 |
|
- |
| 9.1(Luminous Flux) |
- |
5000 |
|
- |
| 9.2(Luminous intensity distribution, peak intensity and beam angle) |
- |
5000 |
|
- |
| 9.3(Luminous Efficacy) |
- |
5000 |
|
- |
| 10(COLORIMETRIC CHARACTERISTICS) |
- |
5000 |
|
- |
| 11(Lamp Life) |
- |
155000 |
|
- |
| 12(Dimming) |
- |
0 |
|
- |
| 14.1(Type Tests) |
- |
1000 |
|
- |
| 14.2(Acceptance Tests) |
- |
1000 |
|
- |
|
- |
- Included w.e.f. 10.07.2024
Exclusion: Cl.8.4 (Emission of Radio Frequency Disturbances) |
| 90 |
IS 11037 (2019) |
Electronic Type Fan Regulators — Specification ( First Revision ) |
- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.1 (a)(Marking ) |
- |
83 |
|
- |
| 9.1 (b)(Marking ) |
- |
83 |
|
- |
| 9.1 (c)(Marking ) |
- |
83 |
|
- |
| 9.1 (d)(Marking ) |
- |
83 |
|
- |
| 9.1 (e)(Marking ) |
- |
83 |
|
- |
| 9.1 (f)(Marking ) |
- |
83 |
|
- |
| 9.2(Marking ) |
- |
500 |
|
- |
| 6.1(Design and General Construction) |
- |
200 |
|
- |
| 6.2(Design and General Construction) |
- |
200 |
|
- |
| 6.3(Design and General Construction) |
- |
200 |
|
- |
| 6.5(Design and General Construction) |
- |
200 |
|
- |
| 6.6(Design and General Construction) |
- |
200 |
|
- |
| 9.5.1 , 7.3(Temperature Rise) |
- |
1500 |
|
- |
| 9.5.1 , 7.3 (a)(Temperature Rise ) |
- |
750 |
|
- |
| 9.5.1 , 7.3 (b)(Temperature Rise) |
- |
750 |
|
- |
| 9.5.1 , 7.3 (b)(Temperature Rise) |
- |
750 |
|
- |
| 9.5.1 , 7.3 (b)(Temperature Rise) |
- |
750 |
|
- |
| 9.5.2, 7.2(Leakage Current Test(as per Cl.13.2 of IS 302 (Part 1).) |
- |
1000 |
|
- |
| 9.5.3(High Voltage Test) |
- |
1500 |
|
- |
| 9.5.5(Earthing Connection) |
- |
1000 |
|
- |
| 9.5.6(Protection against electric shock (as per Cl.8 of IS 302 (Part 1)) |
- |
1000 |
|
- |
| 7.6(General and safety requirements) |
- |
1000 |
|
- |
| 7.7(Voltage drop) |
- |
1000 |
|
- |
| 8.1(Performance) |
- |
300 |
|
- |
| 8.2(Performance) |
- |
300 |
|
- |
| 8.3(Performance) |
- |
300 |
|
- |
| 9.5.7, 9.5.4(Moisture Resistance ) |
- |
2500 |
|
- |
| 7.4.1(a)(Mechanical strength ) |
- |
500 |
|
- |
| 7.4.1(b)(Mechanical strength ) |
- |
500 |
|
- |
| 9.5.8, (Mechanical strength (as per Cl.21.1 of IS 302-1:2008)) |
- |
1500 |
|
- |
| 9.5.9, 7.5, Table-1(Creepage Distances and Clearances (as per Cl. 29 of IS 302-1)) |
- |
1000 |
|
- |
| 9.5.9, 7.5, Table-1(Creepage Distances and Clearances (as per Cl. 29 of IS 302-1)) |
- |
1000 |
|
- |
| 9.5.10( Electrical Endurance Test) |
- |
3000 |
|
- |
| 9.5.11.2(Environmental Tests) |
- |
5000 |
|
- |
| 9.5.11.3(Environmental Tests) |
- |
3000 |
|
- |
| 9.5.11.4(Environmental Tests) |
- |
4000 |
|
- |
| 9.5.12(Resistance to Abnormal Heat and to Fire) |
- |
750 |
|
- |
| 9.5.12.1(Resistance to Abnormal Heat and to Fire) |
- |
750 |
|
- |
| 9.5.13(Resistance to Rusting ) |
- |
1500 |
|
- |
| 9.5.14(Checking of Dimensions) |
- |
1500 |
|
- |
| 9.1(Marking ) |
- |
500 |
|
- |
| 9.1 (a)(Marking ) |
- |
83 |
|
- |
| 9.1 (b)(Marking ) |
- |
83 |
|
- |
| 9.1 (c)(Marking ) |
- |
83 |
|
- |
| 9.1 (d)(Marking ) |
- |
83 |
|
- |
| 9.1 (e)(Marking ) |
- |
83 |
|
- |
| 9.1 (f)(Marking ) |
- |
83 |
|
- |
| 9.2(Marking ) |
- |
83 |
|
- |
| 6.1(Design and General Construction) |
- |
200 |
|
- |
| 6.2(Design and General Construction) |
- |
200 |
|
- |
| 6.3(Design and General Construction) |
- |
200 |
|
- |
| 6.5(Design and General Construction) |
- |
200 |
|
- |
| 6.6(Design and General Construction) |
- |
200 |
|
- |
| 9.5.1 , 7.3(Temperature Rise) |
- |
1500 |
|
- |
| 9.5.1 , 7.3 (a)(Temperature Rise ) |
- |
750 |
|
- |
| 9.5.1 , 7.3 (b)(Temperature Rise) |
- |
750 |
|
- |
| 9.5.1 , 7.3 (b)(Temperature Rise) |
- |
750 |
|
- |
| 9.5.1 , 7.3 (b)(Temperature Rise) |
- |
750 |
|
- |
| 9.5.2, 7.2(Leakage Current Test(as per Cl.13.2 of IS 302 (Part 1).) |
- |
1000 |
|
- |
| 9.5.3(High Voltage Test) |
- |
1000 |
|
- |
| 9.5.5(Earthing Connection) |
- |
1000 |
|
- |
| 9.5.6(Protection against electric shock (as per Cl.8 of IS 302 (Part 1)) |
- |
1000 |
|
- |
| 7.6(General and safety requirements) |
- |
1000 |
|
- |
| 7.7(Voltage drop) |
- |
0 |
|
- |
| 8.1(Performance) |
- |
300 |
|
- |
| 8.2(Performance) |
- |
300 |
|
- |
| 8.3(Performance) |
- |
300 |
|
- |
| 9.5.7, 9.5.4(Moisture Resistance ) |
- |
2500 |
|
- |
| 7.4.1(Mechanical strength ) |
- |
1000 |
|
- |
| 7.4.1(a)(Mechanical strength ) |
- |
500 |
|
- |
| 7.4.1(b)(Mechanical strength ) |
- |
500 |
|
- |
| 9.5.8, (Mechanical strength (as per Cl.21.1 of IS 302-1:2008)) |
- |
1500 |
|
- |
| 9.5.9, 7.5, Table-1(Creepage Distances and Clearances (as per Cl. 29 of IS 302-1)) |
- |
1000 |
|
- |
| 9.5.9, 7.5, Table-1(Creepage Distances and Clearances (as per Cl. 29 of IS 302-1)) |
- |
1000 |
|
- |
| 9.5.10( Electrical Endurance Test) |
- |
3000 |
|
- |
| 9.5.11.2(Environmental Tests) |
- |
3000 |
|
- |
| 9.5.11.3(Environmental Tests) |
- |
3000 |
|
- |
| 9.5.11.4(Environmental Tests) |
- |
4000 |
|
- |
| 9.5.12(Resistance to Abnormal Heat and to Fire) |
- |
750 |
|
- |
| 9.5.12.1(Resistance to Abnormal Heat and to Fire) |
- |
750 |
|
- |
| 9.5.13(Resistance to Rusting ) |
- |
1500 |
|
- |
| 9.5.14(Checking of Dimensions) |
- |
1500 |
|
- |
|
- |
- - |