1 |
IS 302 : Part 2 : Sec 202 (1992) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 202 electric stoves |
-
|
14500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Classification- IS 302-1 ) |
- |
0 |
|
- |
7.1(Marking- IS 302-1) |
- |
500 |
|
- |
7.3(Marking- IS 302-1) |
- |
0 |
|
- |
7.4(Marking- IS 302-1) |
- |
0 |
|
- |
7.6(Marking- IS 302-1) |
- |
0 |
|
- |
7.11(Marking- IS 302-1) |
- |
0 |
|
- |
7.12(Marking- IS 302-1) |
- |
0 |
|
- |
7.13(Marking- IS 302-1) |
- |
0 |
|
- |
7.14(Marking- IS 302-1) |
- |
0 |
|
- |
7.15(Marking- IS 302-1) |
- |
0 |
|
- |
7.101(Marking) |
- |
0 |
|
- |
8( Protection Against Electric Shock, IS 302-1) |
- |
500 |
|
- |
10(Power Input and Current, IS 302-1) |
- |
1000 |
|
- |
11(Heating, IS 302-1) |
- |
1000 |
|
- |
13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
- |
15.1(Moisture Resistance, IS 302-1) |
- |
1000 |
|
- |
15.3(Moisture Resistance, IS 302-1) |
- |
1000 |
|
- |
16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
- |
19.2(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
19.3(Abnormal Operation, IS 302-1) |
- |
0 |
|
- |
20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
- |
21.1(Mechanical Strength, IS 302-1 & IS 302-2-202) |
- |
500 |
|
- |
22(Construction, IS 302-1) |
- |
1000 |
|
- |
22.101(Construction) |
- |
0 |
|
- |
22.102(Construction) |
- |
0 |
|
- |
22.103(Construction) |
- |
0 |
|
- |
22.104(Construction) |
- |
0 |
|
- |
22.105(Construction) |
- |
0 |
|
- |
22.105.1(Construction) |
- |
0 |
|
- |
22.105.2(Construction) |
- |
0 |
|
- |
22.106(Construction) |
- |
0 |
|
- |
22.107(Construction) |
- |
0 |
|
- |
11.107.1(Construction) |
- |
0 |
|
- |
23.1(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
23.2(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
23.8(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
23.9(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
23.10(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
24.1(Components, IS 302-1) |
- |
500 |
|
- |
24.2(Components, IS 302-1) |
- |
0 |
|
- |
24.101(Components) |
- |
0 |
|
- |
25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.4(Supply Connection and External Flexible Cords) |
- |
0 |
|
- |
25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
26(Terminals for External Conductors, IS 302-1) |
- |
500 |
|
- |
27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
27.2(Provision for Earthing, IS 302-1) |
- |
500 |
|
- |
27.3(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
27.4(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
28(Screws & Connections, IS 302-1) |
- |
500 |
|
- |
29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
500 |
|
- |
29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
- |
30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
- |
31(Resistance of Rusting, IS 302-1) |
- |
500 |
|
- |
|
Complete
|
|
- |
- |
2 |
IS 16333 : Part 3 (2022) |
Mobile phone handsets: Part 3 Indian language support for mobile phone handsets - Specific requirements(Second Revision) |
-
|
5000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1(Inputting of text) |
- |
2000 |
|
- |
5.2(Message Readability) |
- |
2000 |
|
- |
6(Marking) |
- |
1000 |
|
- |
|
Complete
|
|
- |
- |
3 |
IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
-
|
30000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.5(Components) |
- |
1000 |
|
- |
4.6(Power interface) |
- |
2500 |
|
- |
4.7(Marking & instructions) |
- |
1000 |
|
- |
5.1(Protection against shock and energy hazards) |
- |
2000 |
|
- |
5.2(Requirement of auxiliary circuits) |
- |
2000 |
|
- |
5.3(Protective earthing and bonding) |
- |
3000 |
|
- |
5.4(AC and DC power isolation) |
- |
2500 |
|
- |
5.5(Over current and earth fault condition) |
- |
3000 |
|
- |
5.6(Safety interlocks) |
- |
2500 |
|
- |
5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
3000 |
|
- |
6.1(Wiring, connections and supply) |
- |
3000 |
|
- |
6.2(Connection to power) |
- |
2000 |
|
- |
6.3(Wiring terminals for external power conductors) |
- |
2000 |
|
- |
7.1(Enclosure) |
- |
2500 |
|
- |
7.2(STABILITY) |
- |
2000 |
|
- |
7.3(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
7.4(Construction details) |
- |
500 |
|
- |
7.5(Resistance to fire) |
- |
1000 |
|
- |
7.6(Battery location) |
- |
1000 |
|
- |
7.7(Temperature rise) |
- |
2000 |
|
- |
8.1(General procision for earth leakage) |
- |
1000 |
|
- |
8.2(Electric Strength) |
- |
2500 |
|
- |
8.3(Abnormal operating and fault conditions) |
- |
2000 |
|
- |
9.0(Connection to telecommunication networks) |
- |
1000 |
|
- |
3.2.4(Appliances inlets/connectors) |
- |
1000 |
|
- |
|
Complete
|
|
- |
- |
4 |
IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
-
|
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking and instructions) |
- |
500 |
|
- |
7(Heating under normal operating conditions) |
- |
1500 |
|
- |
8(Constructional requirements with regard to the protection against electric shock) |
- |
1500 |
|
- |
9(Electric shock hazard under normal operating conditions) |
- |
1500 |
|
- |
10(Insulation requirements) |
- |
1500 |
|
- |
11(Fault conditions) |
- |
1500 |
|
- |
12(Mechanical strength) |
- |
1500 |
|
- |
13(CLEARANCES and CREEPAGE DISTANCES) |
- |
1500 |
|
- |
15(TERMINALS) |
- |
1500 |
|
- |
16(External flexible cords) |
- |
1500 |
|
- |
17(Electrical connections and mechanical fixings) |
- |
1500 |
|
- |
19(Stability and mechanical hazards) |
- |
1500 |
|
- |
20(Resistance to fire) |
- |
1500 |
|
- |
Annex-B(Apparatus to be connected to the TELECOMMUNICATION NETWORKS) |
- |
1500 |
|
- |
|
Complete
|
|
- |
- |
5 |
IS 10322 : Part 5 : Sec 4 (1987) |
Specification for luminaires: Part 5 particular requirements: Sec 4 portable general purpose luminaires |
-
|
35000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
13.8(Photometric Test) |
- |
10000 |
|
- |
13.7(Resistance to Heat,
Fire & Tracking) |
- |
3000 |
|
- |
13.6(Insulation Resistance
and Electric Strength) |
- |
1000 |
|
- |
13.5(Resistance To
Dust & Moisture) |
- |
3000 |
|
- |
13.4(Endurance Test
and Thermal test) |
- |
7000 |
|
- |
13.3(Mechanical
Strength Test ) |
- |
1000 |
|
- |
11(Protection Against
Electric Shock ) |
- |
1000 |
|
- |
10(External &
Internal Wiring) |
- |
1000 |
|
- |
9(Terminals) |
- |
1000 |
|
- |
8(Provision for
Earthing) |
- |
1000 |
|
- |
7(Creepage Distance
And Clearances) |
- |
2000 |
|
- |
6(Construction) |
- |
3000 |
|
- |
5(Marking) |
- |
1000 |
|
- |
|
Complete
|
|
- |
- |
6 |
IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
-
|
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
1.5(Components) |
- |
500 |
|
- |
1.6(Power interface .) |
- |
1000 |
|
- |
1.7(Markings and instructions) |
- |
1000 |
|
- |
2.1(Protection from electric shock and energy hazards) |
- |
1000 |
|
- |
2.2(SELV circuits) |
- |
1000 |
|
- |
2.3(TNV circuits) |
- |
1000 |
|
- |
2.4(Limited current circuits) |
- |
2500 |
|
- |
2.5(Limited power sources .) |
- |
1000 |
|
- |
2.6(Provisions for earthing and bonding) |
- |
500 |
|
- |
2.7(Overcurrent and earth fault protection in primary circuits) |
- |
1000 |
|
- |
2.8(Safety interlocks) |
- |
1000 |
|
- |
2.9(Electrical insulation) |
- |
5000 |
|
- |
2.10(Clearances, creepage distances and distances through insulation) |
- |
2500 |
|
- |
3.1(General) |
- |
1000 |
|
- |
3.2(Connection to a mains supply) |
- |
2000 |
|
- |
3.3(Wiring terminals for connection of external conductors) |
- |
1500 |
|
- |
3.4(Disconnection from the mains supply) |
- |
1000 |
|
- |
3.5(Interconnection of equipment) |
- |
1500 |
|
- |
4.1(Stability) |
- |
1000 |
|
- |
4.2(Mechanical strength) |
- |
2000 |
|
- |
4.3(Design and construction) |
- |
500 |
|
- |
4.4(Protection against hazardous moving parts) |
- |
1000 |
|
- |
4.5(Thermal requirements) |
- |
2500 |
|
- |
4.6(Openings in enclosures) |
- |
500 |
|
- |
4.7(Resistance to fire) |
- |
2000 |
|
- |
5.1(Touch current and protective conductor curren) |
- |
3000 |
|
- |
5.2(Electric strength) |
- |
2000 |
|
- |
5.3(Abnormal operating and fault conditions) |
- |
2000 |
|
- |
6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
1500 |
|
- |
6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
1000 |
|
- |
6.3(Protection of the telecommunication wiring system from overheating) |
- |
1000 |
|
- |
7.1(General) |
- |
1000 |
|
- |
7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
1000 |
|
- |
7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
1000 |
|
- |
7.4(Insulation between primary circuits and cable distribution systems) |
- |
1500 |
|
- |
2.8.2/2.8.5(Interlock switches) |
- |
1000 |
|
- |
2.10.4.2(Material Group and Comparative Tracking Index) |
- |
1000 |
|
- |
2.10.5.3(Insulating Compound as Solid Insulation) |
- |
1200 |
|
- |
2.10.5.6(Thin sheet materials) |
- |
1000 |
|
- |
2.10.6(PCB material) |
- |
1500 |
|
- |
2.10.8.2(Thermal conditioning (thermal ageing)) |
- |
1000 |
|
- |
2.10.8.4(Abrasion resistance test) |
- |
1000 |
|
- |
2.10.9(Thermal Cycling) |
- |
1500 |
|
- |
2.10.10(Test for Pollution Degree 1 environment and for insulating compound) |
- |
1000 |
|
- |
2.10.11(Tests for semiconductor devices and for cemented joints) |
- |
1500 |
|
- |
2.10.12(Enclosed and sealed parts) |
- |
1000 |
|
- |
3.1.4(Internal wire) |
- |
1200 |
|
- |
3.2.4(Appliance inlet /connector) |
- |
1500 |
|
- |
Annex Q(Voltage Dependent Resistors) |
- |
1000 |
|
- |
Annex K(Thermal Control) |
- |
1000 |
|
- |
Annex B(Motor tests under abnormal conditions) |
- |
1000 |
|
- |
Annex C(Transformers) |
- |
1000 |
|
- |
Annex DD(Requirements for the mounting means of a rack mounted equipment) |
- |
1000 |
|
- |
Annex EE(Household and home/ office document/ media shredders) |
- |
1000 |
|
- |
4.6.2(Bottoms of fire enclosures) |
- |
1000 |
|
- |
|
Complete
|
|
- |
- |
7 |
IS 16103 : Part 1 (2012) |
Led modules for general lighting: Part 1 safety requirements |
-
|
35000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking) |
- |
1000 |
|
- |
8(Terminals) |
- |
2000 |
|
- |
9(PROVISION FOR EARTHING) |
- |
1500 |
|
- |
10(Protection against accidental contact with live parts) |
- |
3000 |
|
- |
11(Mositure Resistance and Insulation) |
- |
8000 |
|
- |
12(Electric Strength) |
- |
2000 |
|
- |
13(Fault conditions) |
- |
2000 |
|
- |
15(Construction) |
- |
6000 |
|
- |
16(Creepage distance and clearances) |
- |
2000 |
|
- |
17(Screws, current carrying parts and connections) |
- |
2000 |
|
- |
18(Resistance to heat, fire and tracking) |
- |
3000 |
|
- |
19(Resistance to corrosion) |
- |
2000 |
|
- |
21(Heat management) |
- |
500 |
|
- |
|
Complete
|
|
- |
- |
8 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
-
|
35000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking) |
- |
1000 |
|
- |
6(Interchangeability) |
- |
3000 |
|
- |
7(Protection against accidental contact with live parts) |
- |
2000 |
|
- |
8(Insulation Resistance and Electric Strength) |
- |
6000 |
|
- |
8(Strength after humidity treatment) |
- |
2000 |
|
- |
9(MECHANICAL STRENGTH) |
- |
3000 |
|
- |
10(cap temperature) |
- |
5000 |
|
- |
11(Resistance to Heat) |
- |
3000 |
|
- |
12(Resistance to Flame and Ignition) |
- |
3000 |
|
- |
13(Fault conditions) |
- |
5000 |
|
- |
14(Creepage distance and clearances) |
- |
2000 |
|
- |
|
Complete
|
|
- |
- |
9 |
IS 1293 (2019) |
Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) |
-
|
16500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Ratings) |
- |
0 |
|
- |
7.1.1(Accessories Classification) |
- |
500 |
|
- |
7.1.2(Accessories Classification) |
- |
0 |
|
- |
7.1.3(Accessories Classification) |
- |
0 |
|
- |
7.1.4(Accessories Classification) |
- |
0 |
|
- |
7.1.5(Accessories Classification) |
- |
0 |
|
- |
7.2.1(Socket-Outlets Classification) |
- |
500 |
|
- |
7.2.2(Socket-Outlets Classification) |
- |
0 |
|
- |
7.2.3(Socket-Outlets Classification) |
- |
0 |
|
- |
7.2.4(Socket-Outlets Classification) |
- |
0 |
|
- |
7.3(Plug Classification) |
- |
500 |
|
- |
8.1(MARKING) |
- |
500 |
|
- |
8.8(MARKING) |
- |
0 |
|
- |
8.9(MARKING) |
- |
0 |
|
- |
9.1(CHECKING OF DIMENSIONS) |
- |
500 |
|
- |
9.2(CHECKING OF DIMENSIONS) |
- |
0 |
|
- |
10.1(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
500 |
|
- |
10.3(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
0 |
|
- |
10.4(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
0 |
|
- |
10.5(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
0 |
|
- |
10.6(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
0 |
|
- |
10.7(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
0 |
|
- |
11.1(PROVISIONS FOR EARTHING) |
- |
500 |
|
- |
11.2(PROVISIONS FOR EARTHING) |
- |
0 |
|
- |
11.3(PROVISIONS FOR EARTHING) |
- |
0 |
|
- |
11.5(PROVISIONS FOR EARTHING) |
- |
0 |
|
- |
11.6(PROVISIONS FOR EARTHING) |
- |
0 |
|
- |
12.1.1(TERMINALS) |
- |
500 |
|
- |
12.1.2(TERMINALS) |
- |
0 |
|
- |
12.2.1(TERMINALS) |
- |
500 |
|
- |
12.2.2(TERMINALS) |
- |
0 |
|
- |
12.2.3(TERMINALS) |
- |
0 |
|
- |
12.2.4(TERMINALS) |
- |
0 |
|
- |
12.2.5(TERMINALS) |
- |
0 |
|
- |
12.2.6(TERMINALS) |
- |
0 |
|
- |
12.2.7(TERMINALS) |
- |
0 |
|
- |
12.2.8(TERMINALS) |
- |
0 |
|
- |
12.2.9(TERMINALS) |
- |
0 |
|
- |
12.2.10(TERMINALS) |
- |
0 |
|
- |
12.2.11(TERMINALS) |
- |
0 |
|
- |
12.3.1(TERMINALS) |
- |
500 |
|
- |
12.3.2(TERMINALS) |
- |
0 |
|
- |
12.3.3(TERMINALS) |
- |
0 |
|
- |
12.3.4(TERMINALS) |
- |
0 |
|
- |
12.3.5(TERMINALS) |
- |
0 |
|
- |
12.3.6(TERMINALS) |
- |
0 |
|
- |
12.3.7(TERMINALS) |
- |
0 |
|
- |
12.3.8(TERMINALS) |
- |
0 |
|
- |
12.3.9(TERMINALS) |
- |
0 |
|
- |
12.3.10(TERMINALS) |
- |
0 |
|
- |
12.3.11(TERMINALS) |
- |
0 |
|
- |
12.3.12(TERMINALS) |
- |
0 |
|
- |
13.1(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.2(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.3(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.4(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.5(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.6(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.7(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.8(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.9(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.1(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.11(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.12(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.13(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.14(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.15(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.16(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.17(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.18(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.19(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.2(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.21(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.22(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
13.23(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
500 |
|
- |
14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
1000 |
|
- |
14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.3(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.4(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.5(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.6(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.7(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.8(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.9(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.11(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.12(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.13(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.14(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.15(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.16(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.17(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.18(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.19(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.21(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.22(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.23(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.23.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
0 |
|
- |
14.23.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
0 |
|
- |
14.24(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.25(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
14.26(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
500 |
|
- |
15(INTERLOCKED SOCKET-OUTLETS) |
- |
1000 |
|
- |
16.1(RESISTANCE TO AGEING,) |
- |
1000 |
|
- |
16.2(RESISTANCE TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
500 |
|
- |
16.3(Resistance to Humidity) |
- |
1000 |
|
- |
17.1(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
500 |
|
- |
17.2(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
0 |
|
- |
17.3(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
0 |
|
- |
18(OPERATION OF EARTHING CONTACTS) |
- |
500 |
|
- |
19(TEMPERATURE RISE) |
- |
1000 |
|
- |
20(BREAKING CAPACITY) |
- |
1000 |
|
- |
21(NORMAL OPERATION) |
- |
500 |
|
- |
22.1(Verification of the Maximum Withdrawal Force) |
- |
500 |
|
- |
22.2(Verification of Minimum Withdrawal Force) |
- |
0 |
|
- |
23.1(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
500 |
|
- |
23.3(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
0 |
|
- |
23.4(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
0 |
|
- |
24.1(MECHANICAL STRENGTH
For all kinds of fixed socket-outlets
) |
- |
1000 |
|
- |
24.2(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
500 |
|
- |
24.3(MECHANICAL STRENGTH
for fixed socket-outlets with a main part intended to be mounted directly on a surface) |
- |
500 |
|
- |
24.4(MECHANICAL STRENGTH
For Plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
500 |
|
- |
24.5(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
500 |
|
- |
24.6(MECHANICAL STRENGTH
For screwed glands of accessories having an IP code higher than IP20) |
- |
500 |
|
- |
24.7(MECHANICAL STRENGTH
For plug pins provided with insulating sleeves) |
- |
500 |
|
- |
24.8(MECHANICAL STRENGTH
For shuttered socket-outlets) |
- |
500 |
|
- |
24.9(MECHANICAL STRENGTH
For portable multiple and combined socket outlets
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
500 |
|
- |
24.1(MECHANICAL STRENGTH
For Plug
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
500 |
|
- |
24.11(MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
500 |
|
- |
24.12(MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
500 |
|
- |
24.13(MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
500 |
|
- |
24.14.1(MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
500 |
|
- |
24.14.2(MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
0 |
|
- |
24.14.3(MECHANICAL STRENGTH
For plugs and portable socket-outlets) |
- |
0 |
|
- |
24.15(MECHANICAL STRENGTH
) |
- |
500 |
|
- |
24.16(MECHANICAL STRENGTH
) |
- |
500 |
|
- |
25.1(RESISTANCE TO HEAT
Accessories and surface mounting boxes) |
- |
500 |
|
- |
25.2(RESISTANCE TO HEAT
Parts of insulating material necessary to retain
current-carrying parts of the earthing circuit in position,
as well as parts of the front surface zone of thermoplastic material) |
- |
500 |
|
- |
25.3(RESISTANCE TO HEAT
Parts of insulating material not necessary to retain current-carrying parts and parts of the earthing circuit in position, even though they are in contact with them) |
- |
500 |
|
- |
25.4(RESISTANCE TO HEAT
) |
- |
500 |
|
- |
26.1(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
500 |
|
- |
26.2(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
0 |
|
- |
26.3(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
0 |
|
- |
26.4(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
0 |
|
- |
26.5(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
0 |
|
- |
26.6(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
0 |
|
- |
26.7(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
0 |
|
- |
27.1(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
500 |
|
- |
27.2(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
0 |
|
- |
27.3(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
0 |
|
- |
28.1.1(Resistance to Abnormal Heat and to Fire
Glow-Wire Test) |
- |
500 |
|
- |
28.1.2(Resistance to Abnormal Heat and to Fire
for plugs with pins provided with insulating sleeves) |
- |
0 |
|
- |
28.2(Resistance to Tracking
For accessories other than IP code higher than IPX0 parts of insulating material retaining live parts in position) |
- |
500 |
|
- |
29(RESISTANCE TO RUSTING) |
- |
500 |
|
- |
30.1(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Pressure Test at High Temperature) |
- |
500 |
|
- |
30.2(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Static Damp Heat Test) |
- |
0 |
|
- |
30.3(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Tests at Low Temperature) |
- |
0 |
|
- |
30.4(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Impact Test at Low Temperature) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
10 |
IS 10322 : Part 5 : Sec 9 (2017) |
Luminaires: Part 5 particular requirements: Sec 9 rope lights |
-
|
40000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.4(General Test Requireements) |
- |
0 |
|
- |
21.5(Classification of Luminaires') |
- |
500 |
|
- |
21.6(Marking) |
- |
1000 |
|
- |
21.7(Construction) |
- |
10000 |
|
- |
21.8(Creepage Distance and Clearances) |
- |
2000 |
|
- |
21.10(Terminals) |
- |
1000 |
|
- |
21.11(External & Internal Wiring) |
- |
2000 |
|
- |
21.12(Protection against electric shock) |
- |
1500 |
|
- |
21.13(Endurance Tests and Thermal Tests) |
- |
10000 |
|
- |
21.14(Resistance to Dust & Moisture) |
- |
5000 |
|
- |
21.15(Insulation Resistance and Electric Strength) |
- |
2000 |
|
- |
21.16(Resistance to Heat , fire and tracking) |
- |
5000 |
|
- |
|
Complete
|
|
- |
- |
11 |
IS 10322 : Part 5 : Sec 8 (2013) |
Luminaires: Part 5 particular requirements: Sec 8 emergency lighting |
-
|
55500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General Test Requireements) |
- |
0 |
|
- |
5(Classification of Luminaires') |
- |
500 |
|
- |
6.0(Marking) |
- |
1000 |
|
- |
7.0(Construction) |
- |
8000 |
|
- |
8.0(Creepage Distance and Clearances) |
- |
2000 |
|
- |
9.0(Provision for earthing) |
- |
1500 |
|
- |
10.0(Terminals) |
- |
1000 |
|
- |
12.0(Protection against electric shock) |
- |
1000 |
|
- |
13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
- |
14.0(Resistance to Dust & Moisture) |
- |
5000 |
|
- |
15.0(Insulation Resistance and Electric Strength) |
- |
2000 |
|
- |
16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
- |
18.0(Changeover Operation) |
- |
5000 |
|
- |
19.0(High Temperature Operation) |
- |
2000 |
|
- |
21.0(TEST DEVICES FOR EMERGENCY OPERATION) |
- |
1000 |
|
- |
22.0(REST MODE AND INIHIBITION MODE FACILITIES) |
- |
1000 |
|
- |
17.0(Functional Safety) |
- |
7000 |
|
- |
20.0(BATTERY CHARGERS FOR SELFCONTAINED EMERGENCY LUMINAIRES) |
- |
2000 |
|
- |
|
Complete
|
|
- |
- |
12 |
IS 10322 : Part 5 : Sec 7 (2017) |
Luminaires: Part 5 particular requirements: Sec 7 lighting chains (First Revision) |
-
|
40000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
20.4(General Test Requireements) |
- |
0 |
|
- |
20.5(Classification of Luminaires') |
- |
500 |
|
- |
20.6(Marking) |
- |
2000 |
|
- |
20.7(Construction) |
- |
10000 |
|
- |
20.8(Creepage Distance and Clearances) |
- |
2000 |
|
- |
20.10(Terminals) |
- |
1000 |
|
- |
20.11(External & Internal Wiring) |
- |
1500 |
|
- |
20.12(Protection against electric shock) |
- |
2000 |
|
- |
20.13(Endurance Tests and Thermal Tests) |
- |
10000 |
|
- |
20.14(Resistance to Dust & Moisture) |
- |
5000 |
|
- |
20.15(Insulation Resistance and Electric Strength) |
- |
2000 |
|
- |
20.16(Resistance to Heat , fire and tracking) |
- |
4000 |
|
- |
|
Complete
|
|
- |
- |
13 |
IS 9537 : Part 3 (1983) |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
-
|
4500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1(Marking) |
- |
200 |
|
- |
6.2(Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
200 |
|
- |
6.3(Standard Mark on Conduit) |
- |
200 |
|
- |
7.1.1(Maximum and minimum outside diameter of socket) |
- |
500 |
|
- |
7.1.1 Table-2(Length of Socket end) |
- |
200 |
|
- |
7.1.2(Maximum and minimum outside diameter of conduit) |
- |
200 |
|
- |
7.2(Minimum inside diameter of conduit) |
- |
200 |
|
- |
7.3(Length of conduit) |
- |
300 |
|
- |
7.4(Unifomity of The wall Thickness) |
- |
200 |
|
- |
8.1(Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
300 |
|
- |
9.2(Bending Test i) At Room Temp ii) At Low Temp (-5 ±2°C)) |
- |
200 |
|
- |
9.3(Compression Test as per caluse 9.3 of IS: 9537 (Part 1)-1980) |
- |
300 |
|
- |
9.5(Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
200 |
|
- |
10(Resistance to Heat -Ball presure test) |
- |
200 |
|
- |
11(Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
200 |
|
- |
12(Electrical Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
- |
12(Electrical Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
- |
13(Tests for external influence as per clause 13 of IS: 9537 (Part 1)-1980) |
- |
200 |
|
- |
12(3 Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
- |
9.3(Compression Test (after removal of force) as per caluse 9.3.3 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
- |
9.4(Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
200 |
|
- |
9.2(Bending Test At Low Temp (-5 ±2°C)) |
- |
0 |
|
- |
7.3(Length of conduit) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
14 |
IS 10322 : Part 5 : Sec 6 (2013) |
Luminaires: Part 5 particular requirements: Sec 6 handlamps |
-
|
40000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General Test Requireements) |
- |
0 |
|
- |
5(Classification of Luminaires') |
- |
500 |
|
- |
6.0(Marking) |
- |
1000 |
|
- |
7.0(Construction) |
- |
10000 |
|
- |
8.0(Creepage Distance and Clearances) |
- |
2000 |
|
- |
9.0(Provision for earthing) |
- |
0 |
|
- |
10.0(Terminals) |
- |
1000 |
|
- |
11.0(External & Internal Wiring) |
- |
4000 |
|
- |
12.0(Protection against electric shock) |
- |
1500 |
|
- |
13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
- |
14.0(Resistance to Dust & Moisture) |
- |
5000 |
|
- |
15.0(Insulation Resistance and Electric Strength) |
- |
2000 |
|
- |
16.0(Resistance to Heat , fire and tracking) |
- |
3000 |
|
- |
|
Complete
|
|
- |
- |
15 |
IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
-
|
30000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking) |
- |
1000 |
|
- |
8(Protection against accidental contact with live parts) |
- |
1000 |
|
- |
9(Terminals) |
- |
1500 |
|
- |
10(PROVISION FOR EARTHING) |
- |
1000 |
|
- |
11(MOISTURE RESISTANCE) |
- |
4000 |
|
- |
12(Electric Strength) |
- |
1000 |
|
- |
13(Thermal endurance test for winding of ballasts) |
- |
0 |
|
- |
14(Fault conditions) |
- |
3000 |
|
- |
15(Transformer heating) |
- |
7000 |
|
- |
16(Construction) |
- |
5000 |
|
- |
17(Creepage distance and clearances) |
- |
2000 |
|
- |
18(Screws, current carrying parts and connections) |
- |
1000 |
|
- |
19(Resistance to heat, fire and tracking) |
- |
2000 |
|
- |
20(Resistance to corrosion) |
- |
500 |
|
- |
|
Complete
|
|
- |
- |
16 |
IS 3854 (1997) |
Switches for domestic and similar purposes - Specification (Second Revision) |
-
|
13000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8(Marking) |
- |
500 |
|
- |
8.9(Marking) |
- |
0 |
|
- |
6(Rating) |
- |
0 |
|
- |
7(Classification) |
- |
0 |
|
- |
10(Protection against Electric Shock) |
- |
500 |
|
- |
11.1(Provision for earthing) |
- |
500 |
|
- |
12(Terminals) |
- |
500 |
|
- |
12.2.1(Terminals) |
- |
0 |
|
- |
12.2.2(Connection of conductor) |
- |
0 |
|
- |
12.2.3(Mechanical strength of terminals) |
- |
0 |
|
- |
12.2.4(Resistance to corrosion) |
- |
0 |
|
- |
12.2.5(Undue damage to conductor) |
- |
0 |
|
- |
12.2.7(Insertion of conductor) |
- |
0 |
|
- |
12.2.9(Locking against accidental loosening) |
- |
0 |
|
- |
12.2.11(Distance between screw and conductor) |
- |
0 |
|
- |
12.3.2(Screwless terminals) |
- |
0 |
|
- |
12.3.3(Connectin of conductor) |
- |
0 |
|
- |
12.3.4(Material of terminals) |
- |
0 |
|
- |
12.3.5(Clamping) |
- |
0 |
|
- |
12.3.7(v) Interconnection of conductors [Cl. 12.3.7]) |
- |
0 |
|
- |
12.3.11(vi) Electrical & Thermal Stresses [Cl 12.3.11]) |
- |
0 |
|
- |
12.3.12(vii) Deflection Stresses [Cl. 12.3.12]) |
- |
0 |
|
- |
13.1(a) Insulating lining, barriers and the like [Cl 13.1]) |
- |
1000 |
|
- |
13.2(b) Construction of switch [Cl 13.2]) |
- |
0 |
|
- |
13.2(i) Installation Test) |
- |
0 |
|
- |
13.3(c) Covers,cover plates and actuating members [Cl 13.3]) |
- |
0 |
|
- |
13.4(d) Ordinary switches [Cl 13.4]) |
- |
0 |
|
- |
13.5(e) Rotary switches [Cl 13.5]) |
- |
0 |
|
- |
13.6(f) Screws and other means [Cl 13.6]) |
- |
0 |
|
- |
13.7(g) Combination of switches or switches and socket outlets [Cl 13.7]) |
- |
0 |
|
- |
13.8(h) Assessories combined with switches [Cl. 13.8]) |
- |
0 |
|
- |
13.9(j) Switches other than ordinary switches [Cl. 13.9]) |
- |
0 |
|
- |
13.1(k) Switches to be installed in a box [Cl. 13.10]) |
- |
0 |
|
- |
13.11(l) Surface type switches other than ordinary switch [Cl. 13.11]) |
- |
0 |
|
- |
13.12, 13.13, 13.14(m) Inlet opening [Cl. 13.12.13.13 & 13.14]) |
- |
0 |
|
- |
13.15(q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
0 |
|
- |
14(Mechanism [Cl. 14]) |
- |
1000 |
|
- |
14.4(Mechanism) |
- |
0 |
|
- |
15.1(Resistance to Ageing, to Harmful Ingress of water and to Humidity [Cl. 15]: Resistance to Ageing, [Cl. 15.1]) |
- |
500 |
|
- |
15.2(b)Resistance to Harmful ingress of water [Cl. 15.2]) |
- |
500 |
|
- |
15.3(c) Resistance to Humidity [Cl. 15.3]) |
- |
0 |
|
- |
16.1(Insulation resistance [Cl. 16.1]) |
- |
500 |
|
- |
16.2( Electric Strength [Cl. 16.2]) |
- |
0 |
|
- |
17(Temperature- rise [Cl. 17]) |
- |
1000 |
|
- |
18(Marking and breaking Capacity[Cl. 18]) |
- |
1000 |
|
- |
19(Normal Operation [Cl. 19] a) General & Operation) |
- |
500 |
|
- |
19(b) Electric Strength) |
- |
0 |
|
- |
19(c)Temperature-rise ) |
- |
0 |
|
- |
14.3(d)Test for arcing and sparking [Cl 14.3]) |
- |
0 |
|
- |
19.2(Normal Operation (For AX type Switches) [Cl. 19.2]) |
- |
0 |
|
- |
20(Mechanical Strength Test [Cl. 20]) |
- |
1000 |
|
- |
21(Resistance to Heat [Cl.21]) |
- |
500 |
|
- |
22(Screw, Current Carrying Part And Connection [Cl.22]) |
- |
500 |
|
- |
22.1(i) Screw & Nuts [Cl.22.1]) |
- |
0 |
|
- |
22.4(ii) Screw & rivets [Cl . 22.4]) |
- |
0 |
|
- |
22.3(iii) Electrical Connections [Cl.22.3]) |
- |
0 |
|
- |
22.5(iv) Current carrying part [Cl.22.5]) |
- |
0 |
|
- |
23.2(Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
0 |
|
- |
23(Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
500 |
|
- |
24.1.1(Resistance to Abnormal Heat & Fire [Cl.24.1] [Glow Wire Test] [Cl.24.1.1]) |
- |
1000 |
|
- |
24.2(Resistance to tracking [For Switch other than ordinary] [Cl.24.2]) |
- |
0 |
|
- |
25 of IS 3854 : 1997(Resistance to rusting) |
- |
500 |
|
- |
11.3(Provision for earthing) |
- |
0 |
|
- |
11.2(Provision for earthing) |
- |
0 |
|
- |
12.3.9(Screwless terminal fixing) |
- |
500 |
|
- |
12.3.8(Screwless terminals design) |
- |
0 |
|
- |
12.3.6(Connection) |
- |
0 |
|
- |
12.3.1(Screwless terminals) |
- |
0 |
|
- |
14.6(Mechanism) |
- |
0 |
|
- |
14.5(Mechanism) |
- |
0 |
|
- |
16.3(Flash test) |
- |
0 |
|
- |
20.8(Mechanical Strength Test) |
- |
0 |
|
- |
20.7(Mechanical Strength Test) |
- |
0 |
|
- |
20.6(Mechanical Strength Test) |
- |
0 |
|
- |
20.5(Mechanical Strength Test) |
- |
0 |
|
- |
20.4(Mechanical Strength Test) |
- |
0 |
|
- |
20.3(Mechanical Strength Test) |
- |
0 |
|
- |
20.2(Mechanical Strength Test) |
- |
0 |
|
- |
20.1(Mechanical Strength Test) |
- |
0 |
|
- |
21.2(Resistance to Heat) |
- |
0 |
|
- |
21.1(Resistance to Heat) |
- |
0 |
|
- |
22.2(Measurement and manual test) |
- |
0 |
|
- |
22.6(Inspection and chemical analysis) |
- |
0 |
|
- |
24.1(Resistance of insulating material to abnormal heat, to fire and to tracking
) |
- |
0 |
|
- |
23.2(Creepage distances,
clearances & distance through
sealing compound
) |
- |
0 |
|
- |
23.1(Creepage distances,
clearances & distance through
sealing compound
) |
- |
0 |
|
- |
22.7(Screws, current
carrying parts and connections
) |
- |
0 |
|
- |
22.6(Screws, current
carrying parts and connections
) |
- |
0 |
|
- |
22.5(Screws, current
carrying parts and connections
) |
- |
0 |
|
- |
22.4(Screws, current
carrying parts and connections
) |
- |
0 |
|
- |
22.3(Screws, current
carrying parts and connections
) |
- |
0 |
|
- |
22.2(Screws, current
carrying parts and connections
) |
- |
0 |
|
- |
22.1(Screws, current
carrying parts and connections
) |
- |
0 |
|
- |
21.3(Resistance to heat
) |
- |
0 |
|
- |
21.2(Resistance to heat
) |
- |
0 |
|
- |
21.1(Resistance to heat
) |
- |
0 |
|
- |
20.9(Mechanical
strength
) |
- |
0 |
|
- |
20.8(Mechanical
strength
) |
- |
0 |
|
- |
20.7(Mechanical
strength
) |
- |
0 |
|
- |
20.6 & 24.4.2(Mechanical
strength
) |
- |
0 |
|
- |
20.6 & 24.4.1(Mechanical
strength
) |
- |
0 |
|
- |
20.5 & 24.4.2(Mechanical
strength
) |
- |
0 |
|
- |
20.5 & 24.4.1(Mechanical
strength
) |
- |
0 |
|
- |
20.4.2(Mechanical
strength
) |
- |
0 |
|
- |
20.4.1(Mechanical
strength
) |
- |
0 |
|
- |
20.4(Mechanical
strength
) |
- |
0 |
|
- |
20.3(Mechanical
strength
) |
- |
0 |
|
- |
20.2(Mechanical
strength
) |
- |
0 |
|
- |
20.1(Mechanical
strength
) |
- |
0 |
|
- |
19.2(Normal operation) |
- |
0 |
|
- |
19.1(Normal operation) |
- |
0 |
|
- |
18.2(Making and breaking capacity ) |
- |
0 |
|
- |
18.1(Making and breaking capacity ) |
- |
0 |
|
- |
16(Insulation
resistance and electric strength
) |
- |
0 |
|
- |
15(Resistance to ageing, to harmful ingress of water and to humidity
) |
- |
0 |
|
- |
14.6(Mechanism) |
- |
0 |
|
- |
14.5(Mechanism) |
- |
0 |
|
- |
14.4(Mechanism) |
- |
0 |
|
- |
14.3(Mechanism) |
- |
0 |
|
- |
14.2(Mechanism) |
- |
0 |
|
- |
14.1(Mechanism) |
- |
0 |
|
- |
13.15(Constructional
requirements
) |
- |
0 |
|
- |
13.14(Constructional
requirements
) |
- |
0 |
|
- |
13.13(Constructional
requirements
) |
- |
0 |
|
- |
13.12(Constructional
requirements
) |
- |
0 |
|
- |
13.11(Constructional
requirements
) |
- |
0 |
|
- |
13.9(Constructional
requirements
) |
- |
0 |
|
- |
13(Constructional
requirements
) |
- |
0 |
|
- |
12.3.12(Terminals) |
- |
0 |
|
- |
12.2.10(Terminals) |
- |
0 |
|
- |
12.3.9(Terminals) |
- |
0 |
|
- |
12.2(Terminals) |
- |
0 |
|
- |
11.4(Provision for earthing) |
- |
0 |
|
- |
11.3(Provision for earthing) |
- |
0 |
|
- |
11.2(Provision for earthing) |
- |
0 |
|
- |
11.1(Provision for earthing) |
- |
0 |
|
- |
10.7(Protection against electric shock
) |
- |
0 |
|
- |
10.6(Protection against electric shock
) |
- |
0 |
|
- |
10.5(Protection against electric shock
) |
- |
0 |
|
- |
10.4(Protection against electric shock
) |
- |
0 |
|
- |
10.3(Protection against electric shock
) |
- |
0 |
|
- |
10.2(Protection against electric shock
) |
- |
0 |
|
- |
10.1(Protection against electric shock
) |
- |
0 |
|
- |
8.1(Marking) |
- |
0 |
|
- |
8.2(Marking) |
- |
0 |
|
- |
8.3(Marking) |
- |
0 |
|
- |
8.4(Marking) |
- |
0 |
|
- |
8.5(Marking) |
- |
0 |
|
- |
8.6(Marking) |
- |
0 |
|
- |
8.7(Marking) |
- |
0 |
|
- |
8.8(Marking) |
- |
0 |
|
- |
7.1(Classification) |
- |
0 |
|
- |
7.2(Classification) |
- |
0 |
|
- |
6(Ratings) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
17 |
IS 10322 : Part 5 : Sec 5 (2013) |
Luminaires: Part 5 particular requirements: Sec 5 floodlights (First Revision) |
-
|
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General Test Requireements) |
- |
0 |
|
- |
5(Classification of Luminaires') |
- |
500 |
|
- |
6.0(Marking) |
- |
1000 |
|
- |
7.0(Construction) |
- |
7000 |
|
- |
8.0(Creepage Distance and Clearances) |
- |
2000 |
|
- |
9.0(Provision for earthing) |
- |
2000 |
|
- |
10.0(Terminals) |
- |
1000 |
|
- |
11.0(External & Internal Wiring) |
- |
1500 |
|
- |
12.0(Protection against electric shock) |
- |
2000 |
|
- |
13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
- |
14.0(Resistance to Dust & Moisture) |
- |
5000 |
|
- |
15.0(Insulation Resistance and Electric Strength) |
- |
1000 |
|
- |
16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
- |
17.0(Photometric Test) |
- |
12000 |
|
- |
|
Complete
|
|
- |
- |
18 |
IS 10322 : PART 5 : SEC 3 (2012) |
Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) |
-
|
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General Test Requireements) |
- |
0 |
|
- |
5(Classification of Luminaires') |
- |
500 |
|
- |
6.0(Marking) |
- |
1000 |
|
- |
7.0(Construction) |
- |
7000 |
|
- |
8.0(Creepage Distance and Clearances) |
- |
2000 |
|
- |
9.0(Provision for earthing) |
- |
2000 |
|
- |
10.0(Terminals) |
- |
1000 |
|
- |
11.0(External & Internal Wiring) |
- |
1500 |
|
- |
12.0(Protection against electric shock) |
- |
2000 |
|
- |
13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
- |
14.0(Resistance to Dust & Moisture) |
- |
5000 |
|
- |
15.0(Insulation Resistance and Electric Strength) |
- |
1000 |
|
- |
16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
- |
17.0(Photometric Test) |
- |
12000 |
|
- |
|
Complete
|
|
- |
- |
19 |
IS 302 : Part 2 : Sec 30 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 30 room heaters (First Revision) |
-
|
23000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6 (Classification) |
- |
0 |
|
- |
Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
Cl.7.3(Marking and Instructions) |
- |
0 |
|
- |
Cl.7.4(Marking and Instructions) |
- |
0 |
|
- |
Cl.7.5(Marking and Instructions) |
- |
0 |
|
- |
Cl.7.6 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
Cl.7.8 of IS :302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
Cl.7.10 of IS :302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
Cl.7.11 of IS :302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
Cl.7.13 of IS 302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
Cl.7.14 of IS302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
0 |
|
- |
Cl.7.101(Marking and Instructions) |
- |
0 |
|
- |
Cl.8 & IS:302-1:2008(Protection Against Access to Live Parts) |
- |
500 |
|
- |
Cl.10 & IS:302-1:2008(Power Input and Current) |
- |
1000 |
|
- |
Cl.11 & IS:302-1:2008(Heating) |
- |
2000 |
|
- |
Cl.11.8(Heating) |
- |
0 |
|
- |
Cl.13 & IS:302-1:2008(Leakage Current & Electric Strength at operating temp. ) |
- |
500 |
|
- |
Cl.14 & IS:302-1:2008(Transient Over Voltages) |
- |
1000 |
|
- |
Cl.15 & IS: 302-1:2008(Moisture Resistance
) |
- |
2000 |
|
- |
Cl.15.3 of IS 302-1:200(Moisture Resistance
) |
- |
0 |
|
- |
Cl.16 & IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
500 |
|
- |
Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
3000 |
|
- |
Cl.19.101(Abnormal Operation.) |
- |
0 |
|
- |
Cl.19.102(Abnormal Operation.) |
- |
0 |
|
- |
Cl.19.103(Abnormal Operation.) |
- |
0 |
|
- |
Cl.19.104(Abnormal Operation.) |
- |
0 |
|
- |
Cl.19.105(Abnormal Operation.) |
- |
0 |
|
- |
Cl.19.106(Abnormal Operation.) |
- |
0 |
|
- |
Cl.19.107(Abnormal Operation.) |
- |
0 |
|
- |
Cl.19.108(Abnormal Operation.) |
- |
0 |
|
- |
Cl.19.109(Abnormal Operation.) |
- |
0 |
|
- |
Cl.19.110(Abnormal Operation.) |
- |
0 |
|
- |
Cl.19.111(Abnormal Operation.) |
- |
0 |
|
- |
Cl.19.112(Abnormal Operation.) |
- |
0 |
|
- |
Cl.19.113(Abnormal Operation.) |
- |
0 |
|
- |
Cl.19.114(Abnormal Operation.) |
- |
0 |
|
- |
Cl.20 & IS:302-1:2008(Stability & Mechanical Hazards) |
- |
500 |
|
- |
Cl.21 & IS:302-1:2008)(Mechanical Strength.) |
- |
1000 |
|
- |
Cl.21.2 of IS 302-1:2008(Mechanical Strength.) |
- |
0 |
|
- |
Cl.21.101 (Mechanical Strength.) |
- |
0 |
|
- |
Cl.21.102(Mechanical Strength.) |
- |
0 |
|
- |
Cl.21.103(Mechanical Strength.) |
- |
0 |
|
- |
Cl.22.1 of IS 302-1:2008(Construction) |
- |
1000 |
|
- |
Cl.22.6 of IS 302-1:2008(Construction) |
- |
0 |
|
- |
Cl.22.7 of IS 302-1:2008(Construction) |
- |
0 |
|
- |
Cl.22.8 of IS 302-1:2008(Construction) |
- |
0 |
|
- |
Cl.22.9 of IS 302-1:2008(Construction) |
- |
0 |
|
- |
Cl.22.11(Construction) |
- |
0 |
|
- |
Cl.22.12 of IS 302-1:2008(Construction) |
- |
0 |
|
- |
Cl.22.13 of IS 302-1:2008(Construction) |
- |
0 |
|
- |
Cl.22.14 of IS 302-1:2008(Construction) |
- |
0 |
|
- |
Cl.22.15 of IS 302-1:2008(Construction) |
- |
0 |
|
- |
Cl.22.18 of IS 302-1:2008(Construction) |
- |
0 |
|
- |
Cl.22.20 of IS 302-1:2008(Construction) |
- |
0 |
|
- |
Cl.22.21 of IS 302-1:2008(Construction) |
- |
0 |
|
- |
Cl.23 & IS:302-1:2008(Internal Wiring
) |
- |
1000 |
|
- |
Cl.23.4 & Cl.29 of 302-1:2008(Internal Wiring
) |
- |
0 |
|
- |
Cl.23.5 of 302-1:2008(Internal Wiring
) |
- |
0 |
|
- |
Cl.23.7 of 302-1:2008(Internal Wiring
) |
- |
0 |
|
- |
Cl.24.1 of 302-1:2008(Component) |
- |
2000 |
|
- |
Cl.24.1.3 (Component) |
- |
0 |
|
- |
C.24.1.4(Component) |
- |
0 |
|
- |
C.24.2 of 302-1:2008(Component) |
- |
0 |
|
- |
Cl.24.10(Component) |
- |
0 |
|
- |
Cl.25.1 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
Cl. 25.2 of IS 3021:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
Cl. 25.3 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
Cl. 25.4 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
Cl.25.5 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
Cl.25.6 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
Cl.25.7.(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
Cl.25.8(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
Cl. 25.9(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
Cl.25.10 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
Cl. 25.11(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
Cl. 25.12(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
Cl. 25.13(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
Cl.25.14 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
Cl.25.17 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
Cl.25.18(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
Cl.25.20(Supply Connection and External Flexible Cords ) |
- |
0 |
|
- |
Cl.26.1 of IS 302-1:2008(Terminal for External Conductors
) |
- |
1000 |
|
- |
Cl.26.10 of IS 302-1:2008(Terminal for External Conductors
) |
- |
0 |
|
- |
Cl.26.11 of IS 302-1:2008(Terminal for External Conductors
) |
- |
0 |
|
- |
Cl.27.1 of 302-1:2008(Provision for Earthing.) |
- |
500 |
|
- |
Cl.27.5 of 302-1:2008(Provision for Earthing.) |
- |
0 |
|
- |
Cl.28 of 302-1:2008(Screws and Connections.) |
- |
500 |
|
- |
Cl.29 & IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation) |
- |
1000 |
|
- |
Cl.30 & IS:302-1:2008(Resistance to Heat and Fire) |
- |
2000 |
|
- |
Cl.30.2.2 of 302-1:2008(Resistance to Heat and Fire) |
- |
0 |
|
- |
Cl.31 & IS:302-1:2008(Resistance to Rusting.) |
- |
500 |
|
- |
Cl.32 & IS:302-1:2008(Radition,Toxicity and similar Hazards.) |
- |
0 |
|
- |
Cl.25.7 of IS:302-2-30:2007(Supply Connection and External Flexible Cords : Supply cords material ) |
- |
0 |
|
- |
Cl.22.106 of IS:302-2-30:2007(Construction : Checking of thermostats, timers or similar means for visibl glowing radiant heaters) |
- |
0 |
|
- |
Cl.22.102 & Cl 22.103 of IS:302-2-30:2007(Construction : Fireguard ) |
- |
0 |
|
- |
Cl.22.101 of IS:302-2-30:2007(Construction : Prevention to contact with heating element) |
- |
0 |
|
- |
Cl.22.7 of IS:302-2-30:2007(Construction : Pressure test of oil heater ) |
- |
0 |
|
- |
Cl.21.101 of IS:302-2-30:2007(Mechanical Strength : fire gaurd deformation test ) |
- |
0 |
|
- |
Cl.20 of IS:302-2-30:2007(Stability of Mechanical Hazards) |
- |
0 |
|
- |
Cl.19.114 of IS:302-2-30:2007(Abnormal Operation : the temp. of the surface of the container for oil heaters ) |
- |
0 |
|
- |
Cl.19.112 of IS:302-2-30:2007(Abnormal Operation : Ignition of bleached cotton gauge) |
- |
0 |
|
- |
Cl.19.111 of IS:302-2-30:2007(Abnormal Operation : Ignition of flannelette for Visibly glowing heaters) |
- |
0 |
|
- |
Cl.19.110 of IS:302-2-30:2007(Abnormal Operation : operation against wall for visibly glowing radiant heaters ) |
- |
0 |
|
- |
Cl.19.109 of IS:302-2-30:2007(Abnormal Operation : operation against wall for fan heater ) |
- |
0 |
|
- |
Cl.19.106 of IS:302-2-30:2007(Abnormal Operation : Locked rotor of fan hetear ) |
- |
0 |
|
- |
Cl.19.103 , Cl 19.104 of IS:302-2-30:2007(Abnormal Operation : Operation after Covering by cotton) |
- |
0 |
|
- |
Cl.19 of IS:302-2-30:2007(Abnormal Operation : High Voltage ) |
- |
0 |
|
- |
Cl.11.8 of IS:302-2:30: 2007(Heating : For liquid filled radiators the temp. rise of the outer surface of the liquid container) |
- |
0 |
|
- |
Cl.7.101 of IS:302-2:30: 2007(Marking and Instructions : standard mark. ) |
- |
0 |
|
- |
Cl.7.14 of IS302-1:2008(Marking and Instructions : Legibility and durability ) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
20 |
IS 2312 (1967) |
Specification for propeller type AC ventilating fans (First Revision) |
-
|
7500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
13.1(Marking) |
- |
500 |
|
- |
13.1 (a)(Marking) |
- |
0 |
|
- |
13.1 (b)(Marking) |
- |
0 |
|
- |
13.1 (c)(Marking) |
- |
0 |
|
- |
13.1 (d)(Marking) |
- |
0 |
|
- |
13.1 (e)(Marking) |
- |
0 |
|
- |
13.1 (f)(Marking) |
- |
0 |
|
- |
13.1 (g)(Marking) |
- |
0 |
|
- |
13.1 (h)(Marking) |
- |
0 |
|
- |
13.1 (j)(Marking) |
- |
0 |
|
- |
13.2(Marking) |
- |
0 |
|
- |
13.4(Marking) |
- |
0 |
|
- |
3.1(Sizes ) |
- |
500 |
|
- |
4.1(Rated Voltage) |
- |
0 |
|
- |
5.1(Rated frequency) |
- |
0 |
|
- |
6.1(Design and General Construction) |
- |
500 |
|
- |
6.3(Design and General Construction) |
- |
0 |
|
- |
6.4(Design and General Construction) |
- |
0 |
|
- |
6.5(Design and General Construction) |
- |
0 |
|
- |
6.6(Design and General Construction) |
- |
0 |
|
- |
6.7(Design and General Construction) |
- |
0 |
|
- |
6.9(Design and General Construction) |
- |
0 |
|
- |
6.11(Design and General Construction) |
- |
0 |
|
- |
6.12(Design and General Construction) |
- |
0 |
|
- |
7.1(Design and General Construction) |
- |
500 |
|
- |
8.1(Design and General Construction) |
- |
0 |
|
- |
9(Design and General Construction) |
- |
0 |
|
- |
10.1(Starting ) |
- |
500 |
|
- |
11.1(Interchangeability) |
- |
0 |
|
- |
14.2 & 15.1(Air Delivery) |
- |
2000 |
|
- |
14.3.A(Temperature-Rise (for motors)) |
- |
1000 |
|
- |
14.3.B(Temperature-Rise (for regulators)) |
- |
0 |
|
- |
14.4(Moistureproofness (for regulators only)) |
- |
0 |
|
- |
14.5(Mechanical Endurance (for regulators only)) |
- |
0 |
|
- |
14.1 & 14.6(Power factor) |
- |
0 |
|
- |
14.8(High voltage test) |
- |
500 |
|
- |
14.9(Insulation-Resistance) |
- |
500 |
|
- |
14.7(ac leakage) |
- |
500 |
|
- |
14.1(Earthing continuity) |
- |
500 |
|
- |
14.11 & 15.1(Electrical Input) |
- |
500 |
|
- |
14.12 & 16(Fan Speed) |
- |
500 |
|
- |
|
Complete
|
|
- |
- |
21 |
IS 4250 (1980) |
Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) |
-
|
19000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Classification- IS 302-1 ) |
- |
0 |
|
- |
7.1(Marking- IS 302-1) |
- |
500 |
|
- |
8( Protection Against Electric Shock, IS 302-1) |
- |
500 |
|
- |
9(Starting, IS 302-1) |
- |
500 |
|
- |
10(Power Input and Current, IS 302-1) |
- |
1000 |
|
- |
11(Heating, IS 302-1) |
- |
1000 |
|
- |
13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
- |
14(Transient Over Voltages, IS 302-1) |
- |
1000 |
|
- |
15.1(Moisture Resistance, IS 302-1) |
- |
0 |
|
- |
15(Moisture Resistance, IS 302-1) |
- |
2000 |
|
- |
15.2(Moisture Resistance-Spillage test) |
- |
0 |
|
- |
16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
- |
19(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
20(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
- |
21(Mechanical Strength, IS 302-1) |
- |
500 |
|
- |
22.1(Construction) |
- |
500 |
|
- |
22.2(Construction) |
- |
0 |
|
- |
22.3(Construction) |
- |
0 |
|
- |
22.4(Construction) |
- |
0 |
|
- |
22.5(Construction) |
- |
0 |
|
- |
22.6(Construction) |
- |
0 |
|
- |
22.8(Construction) |
- |
0 |
|
- |
22.9(Construction) |
- |
0 |
|
- |
23(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
24.1(Components, IS 302-1) |
- |
500 |
|
- |
24.2(Components) |
- |
0 |
|
- |
24.4(Components) |
- |
0 |
|
- |
24.5(Components) |
- |
0 |
|
- |
24.6(Components) |
- |
0 |
|
- |
24.7(Components) |
- |
0 |
|
- |
24.8(Components) |
- |
0 |
|
- |
24.9(Components) |
- |
0 |
|
- |
25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
26(Terminals for External Conductors, IS 302-1) |
- |
500 |
|
- |
27(Provision for Earthing, IS 302-1) |
- |
500 |
|
- |
28(Screws & Connections, IS 302-1) |
- |
500 |
|
- |
29(Clearances and Distances through Insulation, IS 302-1) |
- |
500 |
|
- |
30(Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
1000 |
|
- |
31(Resistance of Rusting, IS 302-1) |
- |
500 |
|
- |
34.2(Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
1000 |
|
- |
34.3(Whisking egg whites ) |
- |
0 |
|
- |
34.4(IDLI batter-Grinding of black gram) |
- |
0 |
|
- |
34.5.1 (a)(Operational test for juicers ) |
- |
0 |
|
- |
34.5.2(Operational test for juicers ) |
- |
0 |
|
- |
35(Temperature withstand test for bowl) |
- |
500 |
|
- |
36(Test for controls ) |
- |
500 |
|
- |
37(Strength of Assembly ) |
- |
500 |
|
- |
Cl.18(Endurance) |
- |
1000 |
|
- |
|
Complete
|
|
- |
- |
22 |
IS 2994 (1992) |
Electric stoves - Specification (Second Revision) |
-
|
32500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9(Safety Requirements) |
- |
24000 |
|
- |
10(Endurance Test) |
- |
5000 |
|
- |
11(Finish) |
- |
1000 |
|
- |
12(Thermal Efficiency) |
- |
2000 |
|
- |
8(Marking) |
- |
500 |
|
- |
7(Classification) |
- |
0 |
|
- |
6(Rating) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
23 |
IS 10322 : Part 5 : Sec 2 (2012) |
Luminaires: Part 5 particular requirements: Sec 2 recessed luminaires (First Revision) |
-
|
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General Test Requireements) |
- |
0 |
|
- |
5(Classification of Luminaires') |
- |
500 |
|
- |
6(Marking) |
- |
1000 |
|
- |
7(Construction) |
- |
7000 |
|
- |
8(Creepage Distance and Clearances) |
- |
2000 |
|
- |
9(Provision for earthing) |
- |
2000 |
|
- |
10(Terminals) |
- |
1000 |
|
- |
11(External & Internal Wiring) |
- |
1500 |
|
- |
12(Protection against electric shock) |
- |
2000 |
|
- |
13(Endurance Tests and Thermal Tests) |
- |
10000 |
|
- |
14(Resistance to Dust and Moisture) |
- |
5000 |
|
- |
15(Insulation Resistance and Electric Strength) |
- |
1000 |
|
- |
16(Resistance to Heat , fire and tracking) |
- |
5000 |
|
- |
17(Photometric Test) |
- |
12000 |
|
- |
|
Complete
|
|
- |
- |
24 |
IS 368 (2014) |
Electric immersion water heaters - Specification (Fifth Revision) |
-
|
26000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6 of IS 302-‐2-‐201:2008(Classification) |
- |
0 |
|
- |
Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
Cl.8 of IS 302‐2-201: 2008(Protection Against Access to Live Parts) |
- |
500 |
|
- |
Cl.10 of IS 302‐2‐201:2008(Power Input and Current ) |
- |
1000 |
|
- |
Cl.11 of IS 302-2201: 2008(Heating) |
- |
2000 |
|
- |
Cl. 12 of IS 368:2014(Operation under overload conditions of appliances with heating elements) |
- |
2000 |
|
- |
Cl.13 of IS 302-2-201: 2008(Leakage Current & Electric Strength at Operating Temperature) |
- |
500 |
|
- |
Cl.14 of IS 302‐2-201:2008(Transient Over Voltages ) |
- |
1000 |
|
- |
Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
2000 |
|
- |
Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
1000 |
|
- |
Cl.17 of IS 302‐2-201: 2008(Overload Protection of Transformers & Associated Circuits) |
- |
500 |
|
- |
Cl.18 of IS 368:2014(Endurance) |
- |
3000 |
|
- |
Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
2000 |
|
- |
Cl.20 of IS 302-2-201: 2008(Stability & Mechanical Hazards) |
- |
500 |
|
- |
Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
1000 |
|
- |
Cl.22 of IS 302-2-201: 2008(Construction) |
- |
2000 |
|
- |
Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
500 |
|
- |
Cl.24 of IS 302-2-201: 2008(Component) |
- |
500 |
|
- |
Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
Cl.26 of IS 302-2-201: 2008(Terminals for External Conductors) |
- |
500 |
|
- |
Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
500 |
|
- |
Cl.28 of IS 302-2-201: 2008(Screws & Connections ) |
- |
500 |
|
- |
Cl.29 of IS 302-2‐201:2008(Clearances, Creepage Distances and Solid Insulation ) |
- |
500 |
|
- |
Cl.30 of IS 302-2‐201:2008(Resistance to Heat and Fire ) |
- |
2000 |
|
- |
Cl.31 of IS 302-2-201:2008(Resistance of Rusting ) |
- |
500 |
|
- |
Cl.32 of IS 302-2-201:2008(Radiation, Toxicity and Similar Hazards) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
25 |
IS 366 (1991) |
Electric iron - Specification (Fourth Revision) |
-
|
18000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.0(Classification (as per Cl.6 of IS 302-2-3 and Cl.6.1 of IS 302-1)) |
- |
100 |
|
- |
9.0(Protection against access to live parts (as per Cl. 8 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
- |
9.0(Power input and current (as per Cl. 10 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
- |
9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
- |
9.0(Leakage current and Electric Strength at Operating Temperature (as per Cl. 13 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
- |
9.0(Transient Overvoltage (as per of Cl. 14 of IS 302-2-3 and Table 6 of IS 302-1)) |
- |
500 |
|
- |
9.0(Moisture Resistance (as per of Cl.15 of IS 302-2-3 and IS 302-1)) |
- |
1000 |
|
- |
9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
- |
9.0(Staibilty and mechanical hazards (as per of Cl.20 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
- |
9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
1000 |
|
- |
9.0(Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
- |
9.0(Components (as per of Cl.24 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
- |
9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
- |
9.0(Terminals for external conductors (as per of Cl.26 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
- |
9.0(Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
- |
9.0(Screw and connections (as per of Cl.28 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
- |
9.0(Clearances, creepage distances and solid insulation (as per of Cl.29 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
- |
9.0(Resistance to Heat and Fire (as per of Cl.30 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
- |
10.0(Measurement of Heating up time) |
- |
1000 |
|
- |
11.0(Measurement of sole plate temperature) |
- |
1500 |
|
- |
12.0(Measurement of Tempearture Distribution) |
- |
2000 |
|
- |
13.0(Measurement of Initial overswing temperature and Heating up excess temperature) |
- |
1000 |
|
- |
14.0(Measurement of Cyclic fluctuation of temperature of hottest point ) |
- |
500 |
|
- |
16.0(Measurement of Thermostatic staibility) |
- |
500 |
|
- |
6(Rating) |
- |
0 |
|
- |
17(Finish) |
- |
500 |
|
- |
|
Complete
|
|
- |
- |
26 |
IS 302 : Part 2 : Sec 201 (2008) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 201 electric immersion water heaters (First Revision) |
-
|
14000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6 of IS 302-‐2-‐201:2008(Classification) |
- |
500 |
|
- |
Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
Cl.8 of IS 302‐2-201: 2008(Protection Against Access to Live Parts) |
- |
500 |
|
- |
Cl.10 of IS 302‐2‐201:2008(Power Input and Current ) |
- |
500 |
|
- |
Cl.11 of IS 302-2201: 2008(Heating) |
- |
500 |
|
- |
Cl.13 of IS 302-2-201: 2008(Leakage Current & Electric Strength at Operating Temperature) |
- |
500 |
|
- |
Cl.14 of IS 302‐2-201:2008(Transient Over Voltages ) |
- |
1000 |
|
- |
Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
1000 |
|
- |
Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
500 |
|
- |
Cl.17 of IS 302‐2-201: 2008(Overload Protection of Transformers & Associated Circuits) |
- |
500 |
|
- |
Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1000 |
|
- |
Cl.20 of IS 302-2-201: 2008(Stability & Mechanical Hazards) |
- |
500 |
|
- |
Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
1000 |
|
- |
Cl.22 of IS 302-2-201: 2008(Construction) |
- |
500 |
|
- |
Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
500 |
|
- |
Cl.24 of IS 302-2-201: 2008(Component) |
- |
500 |
|
- |
Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
500 |
|
- |
Cl.26 of IS 302-2-201: 2008(Terminals for External Conductors) |
- |
500 |
|
- |
Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
500 |
|
- |
Cl.28 of IS 302-2-201: 2008(Screws & Connections ) |
- |
500 |
|
- |
Cl.29 of IS 302-2‐201:2008(Clearances, Creepage Distances and Solid Insulation ) |
- |
500 |
|
- |
Cl.30 of IS 302-2‐201:2008(Resistance to Heat and Fire ) |
- |
500 |
|
- |
Cl.31 of IS 302-2-201:2008(Resistance of Rusting ) |
- |
500 |
|
- |
Cl.32 of IS 302-2-201:2008(Radiation, Toxicity and Similar Hazards) |
- |
500 |
|
- |
|
Complete
|
|
- |
- |
27 |
IS 4159 (2021) |
Mineral Filled Sheathed Heating Elements |
-
|
19000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
"Cl. 6 IS 4159:2021"(Classification) |
- |
0 |
|
- |
"Cl. 8 IS 4159:2021"(Protection against access to live parts) |
- |
500 |
|
- |
"Cl. 10 IS 4159:2021"(Power Input and Current) |
- |
1000 |
|
- |
"Cl. 11 IS 4159:2021"(Heating) |
- |
2000 |
|
- |
"Cl. 13 IS 4159:2021"(Leakage Current & Electrical Strength at Operating Temperature) |
- |
500 |
|
- |
"Cl. 14 IS 4159:2021"(Transient Over Voltage) |
- |
1000 |
|
- |
"Cl. 15 IS 4159:2021"(Moisture Resistance) |
- |
2000 |
|
- |
"Cl. 16 IS 4159:2021"(Leakage Current and Electric strength) |
- |
500 |
|
- |
"Cl. 17 IS 4159:2021"(Overload protection of transformers and associated circuits.) |
- |
0 |
|
- |
"Cl. 18 IS 4159:2021"(Endurance) |
- |
3000 |
|
- |
"Cl. 19 IS 4159:2021"(Abnormal Operation) |
- |
1500 |
|
- |
"Cl. 20 IS 4159:2021"(Stability and mechanical Hazards) |
- |
500 |
|
- |
"Cl. 21 IS 4159:2021"(Mechanical Strength) |
- |
500 |
|
- |
"Cl. 22 IS 4159:2021"(Construction) |
- |
1000 |
|
- |
"Cl. 23 IS 4159:2021"(Internal Wiring) |
- |
500 |
|
- |
"Cl. 24 IS 4159:2021"(Components) |
- |
500 |
|
- |
"Cl. 25 IS 4159:2021"(Supply Connections and External Flexible Cables and Cords) |
- |
500 |
|
- |
"Cl. 26 IS 4159:2021"(Terminal For External Conductors) |
- |
500 |
|
- |
"Cl. 27 IS 4159:2021"(Provision For Earthing) |
- |
500 |
|
- |
"Cl. 28 IS 4159:2021"(Screws and Connections) |
- |
500 |
|
- |
"Cl. 29 IS 4159:2021"(Creepage Distances, Clearances And Distances Through Insulation) |
- |
500 |
|
- |
"Cl. 30 IS 4159:2021"(Resistance To Heat, Fire And Tracking) |
- |
1000 |
|
- |
"Cl. 31 IS 4159:2021"(Resistance To Rusting) |
- |
500 |
|
- |
"Cl. 102 IS 4159:2021"(Leakage and hydrostatic strength (for oil heating elements)) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
28 |
IS 302 : Part 2 : Sec 3 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 3 electric iron (First Revision) |
-
|
27000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Classification- IS 302-1 ) |
- |
0 |
|
- |
7.1(Marking- IS 302-1) |
- |
500 |
|
- |
7.3(Marking- IS 302-1) |
- |
0 |
|
- |
7.4(Marking- IS 302-1) |
- |
0 |
|
- |
7.6(Marking- IS 302-1) |
- |
0 |
|
- |
7.7(Marking- IS 302-1) |
- |
0 |
|
- |
7.8(Marking- IS 302-1) |
- |
0 |
|
- |
7.11(Marking- IS 302-1) |
- |
0 |
|
- |
7.12(Marking- IS 302-1) |
- |
0 |
|
- |
7.13(Marking- IS 302-1) |
- |
0 |
|
- |
7.14(Marking- IS 302-1) |
- |
0 |
|
- |
7.15(Marking- IS 302-1) |
- |
0 |
|
- |
7.101(Marking) |
- |
0 |
|
- |
8( Protection Against Electric Shock, IS 302-1) |
- |
500 |
|
- |
10(Power Input and Current, IS 302-1) |
- |
1000 |
|
- |
11(Heating, IS 302-1) |
- |
2000 |
|
- |
13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1000 |
|
- |
14(Transient Over Voltages, IS 302-1) |
- |
1000 |
|
- |
15.1(Moisture Resistance, IS 302-1) |
- |
0 |
|
- |
15.2(Moisture Resistance, IS 302-1) |
- |
0 |
|
- |
15.3(Moisture Resistance, IS 302-1) |
- |
2000 |
|
- |
16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1000 |
|
- |
16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
- |
19.4(Abnormal Operation, IS 302-1) |
- |
0 |
|
- |
19.5(Abnormal Operation, IS 302-1) |
- |
0 |
|
- |
19.1(Abnormal Operation) |
- |
2000 |
|
- |
19.101(Abnormal Operation) |
- |
0 |
|
- |
20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
- |
20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
21.101(Mechanical Strength, IS 302-2-3) |
- |
1000 |
|
- |
22(Construction, IS 302-1) |
- |
500 |
|
- |
22.101(Construction) |
- |
500 |
|
- |
22.102(Construction) |
- |
500 |
|
- |
22.103(Construction) |
- |
500 |
|
- |
22.104(Construction) |
- |
500 |
|
- |
22.105(Construction) |
- |
500 |
|
- |
22.106(Construction) |
- |
500 |
|
- |
22.107(Construction) |
- |
500 |
|
- |
23.1(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
23.2(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
23.4(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
23.5(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
23.6(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
23.7(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
23.8(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
23.9(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
23.10(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
24.1(Components, IS 302-1) |
- |
500 |
|
- |
24.2(Components, IS 302-1) |
- |
0 |
|
- |
24.4(Components, IS 302-1) |
- |
0 |
|
- |
24.5(Components, IS 302-1) |
- |
0 |
|
- |
24.6(Components, IS 302-1) |
- |
0 |
|
- |
25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
26(Terminals for External Conductors, IS 302-1) |
- |
2000 |
|
- |
27.1(Provision for Earthing, IS 302-1) |
- |
500 |
|
- |
27.2(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
27.3(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
27.4(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
28(Screws & Connections, IS 302-1) |
- |
1000 |
|
- |
29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
500 |
|
- |
29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
500 |
|
- |
30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
1000 |
|
- |
30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
1000 |
|
- |
31(Resistance of Rusting, IS 302-1) |
- |
500 |
|
- |
32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
0 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
29 |
IS 302 : Part 2 : Sec 26 (2014) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 26 clocks (First Revision) |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking and instructions) |
- |
1000 |
|
- |
8(Protection against live parts) |
- |
1000 |
|
- |
10(POWER INPUT AND CURRENT) |
- |
2000 |
|
- |
11(HEATING) |
- |
3000 |
|
- |
13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1000 |
|
- |
14(TRANSIENT OVERVOLTAGES) |
- |
2000 |
|
- |
15(MOISTURE RESISTANCE) |
- |
5000 |
|
- |
16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1000 |
|
- |
17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1000 |
|
- |
19(ABNORMAL OPERATION) |
- |
5000 |
|
- |
20(STABILITY AND MECHANICAL HAZARDS) |
- |
1000 |
|
- |
21(MECHANICAL STRENGTH) |
- |
2000 |
|
- |
22(CONSTRUCTION) |
- |
5000 |
|
- |
23(INTERNAL WIRING) |
- |
1000 |
|
- |
24(COMPONENTS) |
- |
1000 |
|
- |
25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
2000 |
|
- |
26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
- |
27(PROVISION FOR EARTHING) |
- |
1000 |
|
- |
28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
- |
29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
2000 |
|
- |
30(RESISTANCE TO HEAT AND FIRE) |
- |
5000 |
|
- |
31(RESISTANCE TO RUSTING) |
- |
1000 |
|
- |
32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
0 |
|
- |
22.16(Automatic cord reel) |
- |
0 |
|
- |
22.32(Oxygen bomb for rubber material) |
- |
0 |
|
- |
22.47(Water pressure inlet) |
- |
0 |
|
- |
22.3(Flexing test) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
30 |
IS 302 : Part 2 : Sec 25 (2014) |
Safety of household and similar electrical appliances: Part 2 Particular requirements: Section 25 Microwave ovens |
-
|
52000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Classification) |
- |
0 |
|
- |
7(Marking and instructions) |
- |
1000 |
|
- |
8(Protection against live parts) |
- |
1000 |
|
- |
10(POWER INPUT AND CURRENT) |
- |
2000 |
|
- |
11(HEATING) |
- |
3000 |
|
- |
13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1000 |
|
- |
14(IMPULSE VOLTAGE TEST) |
- |
2000 |
|
- |
15(HUMIDITY TREATMENT TEST) |
- |
5000 |
|
- |
16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1000 |
|
- |
17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1000 |
|
- |
18(ENDURANCE) |
- |
5000 |
|
- |
19(ABNORMAL OPERATION) |
- |
5000 |
|
- |
20(STABILITY AND MECHANICAL HAZARDS) |
- |
1000 |
|
- |
21(MECHANICAL STRENGTH) |
- |
2000 |
|
- |
22(CONSTRUCTION) |
- |
5000 |
|
- |
23(INTERNAL WIRING) |
- |
1000 |
|
- |
24(COMPONENTS) |
- |
1000 |
|
- |
25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
2000 |
|
- |
26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
- |
27(PROVISION FOR EARTHING) |
- |
1000 |
|
- |
28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
- |
29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
2000 |
|
- |
30(RESISTANCE TO HEAT AND FIRE) |
- |
5000 |
|
- |
31(RESISTANCE TO RUSTING) |
- |
1000 |
|
- |
32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
2000 |
|
- |
|
Complete
|
|
- |
- |