| 3181 |
RTRC LIMITED, GURUGRAM
| 9177406
| IS 5950 (2024) |
Shot Firing Cables (for Use Other than in Shafts) - Specification (Second Revision) |
Shot Firing Cables (for Use Other Than in Shafts) — Specification |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Section-2, Cl-3(CONDUCTOR) |
- |
150 |
|
- |
| Section-2, Cl-4(INSULATION) |
- |
150 |
|
- |
| Section-2, Cl-5(SHEATH) |
- |
150 |
|
- |
| Section-3, Cl-6(CONDUCTOR) |
- |
300 |
|
- |
| Section-3, Cl-7.1.1(Thickness of Insulation & Sheath) |
- |
300 |
|
- |
| Section-3, Cl-7.1.2(Type II) |
- |
250 |
|
- |
| Section-3, Cl-7.2(Tolerance on Thickness of Insulation) |
- |
100 |
|
- |
| Section-3, Cl-7.3(Colour of Insulation) |
- |
100 |
|
- |
| Section-3, Cl-8.1(Single-Core) |
- |
500 |
|
- |
| Section-3, Cl-8.2(Tolerance on Thickness of Sheath) |
- |
500 |
|
- |
| Section-3, Cl-8.3(Color of Sheath) |
- |
500 |
|
- |
| Cl-10.2(Voltage Test) |
- |
1000 |
|
- |
| Cl-10.3(Spark Test) |
- |
500 |
|
- |
| Cl-10.4(Flammability Test) |
- |
500 |
|
- |
| Cl-9.1 (a)(Annealing test;) |
- |
500 |
|
- |
| Cl-9.1 (b)(Conductor resistance test) |
- |
1000 |
|
- |
| Cl-9.1 (c)(Test for thickness of insulation and sheath) |
- |
500 |
|
- |
| Cl-9.1 (d) 1(Tensile strength and elongation at break) |
- |
500 |
|
- |
| Cl-9.1 (d) 2(Ageing in air oven) |
- |
500 |
|
- |
| Cl-9.1 (d) 3(Loss of mass test) |
- |
200 |
|
- |
| Cl-9.1 (d) 4(Hot deformation) |
- |
300 |
|
- |
| Cl-9.1 (d) 5(Heat shock) |
- |
500 |
|
- |
| Cl-9.1 (d) 6(hrinkage) |
- |
500 |
|
- |
| Cl-9.2 , e(Insulation resistance test) |
- |
500 |
|
- |
|
03 Apr, 2027 |
- Included w.e.f 29.09.2025 |
| 3182 |
RTRC LIMITED, GURUGRAM
| 9177406
| IS 17046 (2018) |
Fibre Optic Cable for Cable TV Application |
Fibre Optic Cable for Cable TV Application |
130000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Design and construction of aerial metal free optical fibre cable) |
- |
0 |
|
- |
| 3.2(Fibre used in the cable) |
- |
0 |
|
- |
| 3.3(Self-supporting metal free aerial optical fibre cable) |
- |
0 |
|
- |
| 3.4(Technical Requirements) |
- |
4500 |
|
- |
| 3.5(Mechanical Characteristics) |
- |
4500 |
|
- |
| 3.6(Environmental Characteristic of Fibre) |
- |
4500 |
|
- |
| 3.7(Optical Fibre Cable Construction Specifications) |
- |
1000 |
|
- |
| 3.8(Mechanical Characteristics and Tests on Optical Fibre Cable) |
- |
100000 |
|
- |
| 4(Marking) |
- |
500 |
|
- |
|
03 Apr, 2027 |
- Included w.e.f 29.09.2025 |
| 3183 |
Atmy Analytical Labs Private Limited (Unit-2), Greater Noida
| 8176106
| IS 14756 (2024) |
Stainless Steel Utensils - Specification (THIRD REVISION) |
- |
24900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 3.1(Material used for manufacturing utensils) |
- |
0 |
|
- |
| Cl 3.2(Material used for composite bottom) |
- |
0 |
|
- |
| Cl 3.3(Material used for body of utensil of 3-ply construction) |
- |
0 |
|
- |
| Cl 3.4(Material used for stainless steel lid) |
- |
0 |
|
- |
| Cl 3.5(Material used for tempered glass lid) |
- |
0 |
|
- |
| Cl 3.5(Material used for stainless steel rim) |
- |
0 |
|
- |
| Cl 4.2 & Table 1(Minimum Sheet Thickness for Body of Utensil) |
- |
1500 |
|
- |
| Cl 4.2 & Table 2(Minimum Sheet Thickness for Lid of Utensil) |
- |
1500 |
|
- |
| Cl 4.2(Thickness of the finished utensil) |
- |
1500 |
|
- |
| Cl 4.3(Classification) |
- |
500 |
|
- |
| Cl 4.4 (i)(Thickness of Aluminium disc/core) |
- |
1500 |
|
- |
| Cl 4.4 (ii)(Thickness of Protector/cowl) |
- |
1500 |
|
- |
| Cl 4.5(Minimum sheet thickness (3-ply utensil)) |
- |
1500 |
|
- |
| Cl 4.5(Thickness of finished utensil (3-ply utensil)) |
- |
1500 |
|
- |
| Cl 5.1(Manufacturing defect & visual appearance) |
- |
1000 |
|
- |
| CL 5.2(Accessibility for cleaning) |
- |
1000 |
|
- |
| Cl 5.3(Joining of handles to the utensils) |
- |
2500 |
|
- |
| Cl 5.4(Requirement for handles) |
- |
12000 |
|
- |
| Cl 5.5(Welding (Finish)) |
- |
1000 |
|
- |
| Cl 5.6(Finish of 3-ply utensil) |
- |
1000 |
|
- |
| Cl 5.7(Requirement for coating) |
- |
1000 |
|
- |
| Cl 5.8(Coating thickness test) |
- |
1500 |
|
- |
| Cl 5.8(Coating adhesion test) |
- |
1500 |
|
- |
| Cl 5.8.1(Thermal shock test (Coating)) |
- |
4000 |
|
- |
| Cl 6.1(Staining Test (Type Test - Frequency Once in a Year)) |
- |
1500 |
|
- |
| Cl 6.2(Mechanical Shock Test (for Cladded Utensils Only)) |
- |
1500 |
|
- |
| Cl 6.3(Thermal Shock Test (for Cladded Utensils Only)) |
- |
2000 |
|
- |
| Cl 6.4(Dry Heat Test (for Cladded Utensils Only)) |
- |
4000 |
|
- |
| Cl 6.5(Coating Thickness Test (for Copper Deposit)) |
- |
3000 |
|
- |
| Cl 6.6(Thermal shock test (3-ply construction utensil body)) |
- |
5000 |
|
- |
| Cl 6.7(Nominal Capacity Test) |
- |
1000 |
|
- |
| Cl 8(Marking) |
- |
0 |
|
- |
| 3.1(a) Carbon) |
- |
0 |
|
- |
| 3.1(b) Silicon) |
- |
0 |
|
- |
| 3.1(c)Manganese) |
- |
0 |
|
- |
| 3.1(d) Nickel) |
- |
0 |
|
- |
| 3.1(Chromium) |
- |
0 |
|
- |
| 3.1(Sulphu) |
- |
0 |
|
- |
| 3.1(Phosphorus) |
- |
0 |
|
- |
| Stainless Steel Utensils - Specification (THIRD REVISION)(Copper) |
- |
0 |
|
- |
| 3.1(Nitrogen) |
- |
500 |
|
- |
| 3.2 a(a) Carbon) |
- |
500 |
|
- |
| 3.2 a(b) Silicon) |
- |
500 |
|
- |
| 68995(Manganese) |
- |
500 |
|
- |
| 3.2 a(d) Nickel) |
- |
500 |
|
- |
| 3.2 a(Chromium) |
- |
500 |
|
- |
| 3.2 a(Sulphur) |
- |
500 |
|
- |
| 3.2 a(g) Phosphorus) |
- |
500 |
|
- |
| 3.2 a(h) Copper) |
- |
500 |
|
- |
| 3.2 a(Nitrogen) |
- |
500 |
|
- |
| 3.2 b(a) Aluminium) |
- |
500 |
|
- |
| 3.2 b(b) Copper) |
- |
500 |
|
- |
| 3.2 b(c) Magnesium) |
- |
500 |
|
- |
| 3.2 b(d) Silicon) |
- |
500 |
|
- |
| 3.2 b(e) Iron) |
- |
500 |
|
- |
| 3.2 b(f) Manganese) |
- |
0 |
|
- |
| 3.2 b(d) Silicon) |
- |
0 |
|
- |
| 3.2 b(e) Iron) |
- |
0 |
|
- |
| 3.2 b(f) Manganese) |
- |
0 |
|
- |
| 3.2 b(g) Zinc) |
- |
0 |
|
- |
| 3.2 b(h) Titanium) |
- |
0 |
|
- |
| 3.2 b(i) Chromium) |
- |
0 |
|
- |
| 3.2 b(j) Cu+Si+Fe+Mn+Zn+mg) |
- |
0 |
|
- |
| 3.2 b(k) Lead) |
- |
0 |
|
- |
| 3.2 c(a) Carbon) |
- |
0 |
|
- |
| 3.2 c(b) Silicon) |
- |
0 |
|
- |
| 3.2 c(c) Manganese) |
- |
0 |
|
- |
| 3.2 c(d) Nickel) |
- |
0 |
|
- |
| 3.2 c(e) Chromium) |
- |
0 |
|
- |
| 3.2 c(f) Sulphur) |
- |
0 |
|
- |
| 3.2 c(g) Phosphorus) |
- |
0 |
|
- |
| 3.3(a) Inner layer) |
- |
0 |
|
- |
| 3.3(b) Middlelayer) |
- |
0 |
|
- |
| 3.3(c) Outerlayer) |
- |
0 |
|
- |
| 3.4(a) Carbon) |
- |
0 |
|
- |
| 3.4(b) Silicon) |
- |
0 |
|
- |
| 3.4(c) Manganese) |
- |
0 |
|
- |
| 3.4(d) Nickel) |
- |
0 |
|
- |
| 3.4(e) Chromium) |
- |
0 |
|
- |
| 3.4(f) Sulphur) |
- |
0 |
|
- |
| 3.4(g) Phosphorus) |
- |
0 |
|
- |
| 3.4(h) Copper) |
- |
0 |
|
- |
| 3.4(i) Nitrogen) |
- |
0 |
|
- |
| 3.4(Thickness stainless steel lid) |
- |
0 |
|
- |
| 3.5(If the utensils provided with tempered glass lid) |
- |
0 |
|
- |
| 4.1(Shapes and Dimensions) |
- |
0 |
|
- |
| 4.2(Thickness of the sheet) |
- |
0 |
|
- |
| 4.3(Classifications) |
- |
0 |
|
- |
| 4.3(Core Thickness for 3-ply Construction
(asper IS15960)) |
- |
0 |
|
- |
| 4.3(Thickness of protective layer (as per IS 15960)) |
- |
0 |
|
- |
| 4.4(Thickness of 3ply full body utensil) |
- |
0 |
|
- |
| 5(Workmanship and finish) |
- |
0 |
|
- |
| 5.4(Handles) |
- |
0 |
|
- |
| 4.1 of IS 13395(Construction) |
- |
0 |
|
- |
| 4.2 of IS 13395(Materials) |
- |
0 |
|
- |
| 4.3 of IS 13395(Selection and Size) |
- |
0 |
|
- |
| 4.4 of Is 13395(Position of Handle and Knob with Respect to Cookware) |
- |
0 |
|
- |
| 4.5 of IS 13395(Attachment to Cookware) |
- |
0 |
|
- |
| 5.2 of IS 13395(Bending Strength) |
- |
0 |
|
- |
| 5.3 of IS 13395(Torque Strength) |
- |
0 |
|
- |
| 5.4 of IS 13395(Impact Strength) |
- |
0 |
|
- |
| 5.5 of IS 13395(Fatigue Resistance
15 000 cycles withstand) |
- |
0 |
|
- |
| 5.6 of IS 13395(Leakage) |
- |
0 |
|
- |
| 5.7 of IS 13395(Thermal Insulation) |
- |
0 |
|
- |
| 5.8 of IS 13395(Heat Resistance) |
- |
0 |
|
- |
| 5.9 of IS 13395(Washing Resistance) |
- |
0 |
|
- |
| 5.10 of IS 13395(Burning Resistance) |
- |
0 |
|
- |
| 5.5(Material comes in contact with food) |
- |
0 |
|
- |
| 6.1(Staining Test) |
- |
0 |
|
- |
| 6.2(Mechanical Shock Test) |
- |
0 |
|
- |
| 6.3(Thermal Shock Test) |
- |
0 |
|
- |
| 6.4(Dry Heat Test) |
- |
0 |
|
- |
| 6.6(Heat test) |
- |
0 |
|
- |
| 6.7.1(Nominal Capacity Test) |
- |
0 |
|
- |
| 6.7.2(Internal diameter of utensil) |
- |
0 |
|
- |
| Annex C(Test for leaching) |
- |
0 |
|
- |
| Annex C(Sensorial test) |
- |
0 |
|
- |
| Cl 3.1(Material used for manufacturing utensils) |
- |
0 |
|
- |
| Cl 3.2(Material used for composite bottom) |
- |
0 |
|
- |
| Cl 3.3(Material used for body of utensil of 3-ply construction) |
- |
0 |
|
- |
| Cl 3.4(Material used for stainless steel lid) |
- |
0 |
|
- |
| Cl 3.5(Material used for tempered glass lid) |
- |
0 |
|
- |
| Cl 3.5(Material used for stainless steel rim) |
- |
0 |
|
- |
| Cl 4.2 & Table 1(Minimum Sheet Thickness for Body of Utensil) |
- |
0 |
|
- |
| Cl 4.2 & Table 2(Minimum Sheet Thickness for Lid of Utensil) |
- |
0 |
|
- |
| Cl 4.2(Thickness of the finished utensil) |
- |
0 |
|
- |
| Cl 4.3(Classification) |
- |
0 |
|
- |
| Cl 4.4 (i)(Thickness of Aluminium disc/core) |
- |
0 |
|
- |
| Cl 4.4 (ii)(Thickness of Protector/cowl) |
- |
0 |
|
- |
| Cl 4.5(Minimum sheet thickness (3-ply utensil)) |
- |
0 |
|
- |
| Cl 4.5(Thickness of finished utensil (3-ply utensil)) |
- |
0 |
|
- |
| Cl 5.1(Manufacturing defect & visual appearance) |
- |
0 |
|
- |
| CL 5.2(Accessibility for cleaning) |
- |
0 |
|
- |
| Cl 5.3(Joining of handles to the utensils) |
- |
0 |
|
- |
| Cl 5.4(Requirement for handles) |
- |
0 |
|
- |
| Cl 5.5(Welding (Finish)) |
- |
0 |
|
- |
| Cl 5.6(Finish of 3-ply utensil) |
- |
0 |
|
- |
| Cl 5.7(Requirement for coating) |
- |
0 |
|
- |
| Cl 5.8(Coating thickness test) |
- |
0 |
|
- |
| Cl 5.8(Coating adhesion test) |
- |
0 |
|
- |
| Cl 5.8.1(Thermal shock test (Coating)) |
- |
0 |
|
- |
| Cl 6.1(Staining Test (Type Test - Frequency Once in a Year)) |
- |
0 |
|
- |
| Cl 6.2(Mechanical Shock Test (for Cladded Utensils Only)) |
- |
0 |
|
- |
| Cl 6.3(Thermal Shock Test (for Cladded Utensils Only)) |
- |
0 |
|
- |
| Cl 6.4(Dry Heat Test (for Cladded Utensils Only)) |
- |
0 |
|
- |
| Cl 6.5(Coating Thickness Test (for Copper Deposit)) |
- |
0 |
|
- |
| Cl 6.6(Thermal shock test (3-ply construction utensil body)) |
- |
0 |
|
- |
| Cl 6.7(Nominal Capacity Test) |
- |
0 |
|
- |
| Cl 8(Marking) |
- |
0 |
|
- |
| 3.1(a) Carbon) |
- |
0 |
|
- |
| 3.1(b) Silicon) |
- |
0 |
|
- |
| 3.1(c)Manganese) |
- |
0 |
|
- |
| 3.1(d) Nickel) |
- |
0 |
|
- |
| 3.1(Chromium) |
- |
0 |
|
- |
| 3.1(Sulphu) |
- |
0 |
|
- |
| 3.1(Phosphorus) |
- |
0 |
|
- |
| Stainless Steel Utensils - Specification (THIRD REVISION)(Copper) |
- |
0 |
|
- |
| 3.1(Nitrogen) |
- |
0 |
|
- |
| 3.2 a(a) Carbon) |
- |
0 |
|
- |
| 3.2 a(b) Silicon) |
- |
0 |
|
- |
| 68995(Manganese) |
- |
0 |
|
- |
| 3.2 a(d) Nickel) |
- |
0 |
|
- |
| 3.2 a(Chromium) |
- |
0 |
|
- |
| 3.2 a(Sulphur) |
- |
0 |
|
- |
| 3.2 a(g) Phosphorus) |
- |
0 |
|
- |
| 3.2 a(h) Copper) |
- |
0 |
|
- |
| 3.2 a(Nitrogen) |
- |
0 |
|
- |
| 3.2 b(a) Aluminium) |
- |
0 |
|
- |
| 3.2 b(b) Copper) |
- |
0 |
|
- |
| 3.2 b(c) Magnesium) |
- |
0 |
|
- |
| 3.2 b(d) Silicon) |
- |
0 |
|
- |
| 3.2 b(e) Iron) |
- |
0 |
|
- |
| 3.2 b(f) Manganese) |
- |
0 |
|
- |
| 3.2 b(d) Silicon) |
- |
0 |
|
- |
| 3.2 b(e) Iron) |
- |
0 |
|
- |
| 3.2 b(f) Manganese) |
- |
0 |
|
- |
| 3.2 b(g) Zinc) |
- |
0 |
|
- |
| 3.2 b(h) Titanium) |
- |
0 |
|
- |
| 3.2 b(i) Chromium) |
- |
0 |
|
- |
| 3.2 b(j) Cu+Si+Fe+Mn+Zn+mg) |
- |
0 |
|
- |
| 3.2 b(k) Lead) |
- |
0 |
|
- |
| 3.2 c(a) Carbon) |
- |
0 |
|
- |
| 3.2 c(b) Silicon) |
- |
0 |
|
- |
| 3.2 c(c) Manganese) |
- |
0 |
|
- |
| 3.2 c(d) Nickel) |
- |
0 |
|
- |
| 3.2 c(e) Chromium) |
- |
0 |
|
- |
| 3.2 c(f) Sulphur) |
- |
0 |
|
- |
| 3.2 c(g) Phosphorus) |
- |
0 |
|
- |
| 3.3(a) Inner layer) |
- |
0 |
|
- |
| 3.3(b) Middlelayer) |
- |
0 |
|
- |
| 3.3(c) Outerlayer) |
- |
0 |
|
- |
| 3.4(a) Carbon) |
- |
0 |
|
- |
| 3.4(b) Silicon) |
- |
0 |
|
- |
| 3.4(c) Manganese) |
- |
0 |
|
- |
| 3.4(d) Nickel) |
- |
0 |
|
- |
| 3.4(e) Chromium) |
- |
0 |
|
- |
| 3.4(f) Sulphur) |
- |
0 |
|
- |
| 3.4(g) Phosphorus) |
- |
0 |
|
- |
| 3.4(h) Copper) |
- |
0 |
|
- |
| 3.4(i) Nitrogen) |
- |
0 |
|
- |
| 3.4(Thickness stainless steel lid) |
- |
0 |
|
- |
| 3.5(If the utensils provided with tempered glass lid) |
- |
0 |
|
- |
| 4.1(Shapes and Dimensions) |
- |
0 |
|
- |
| 4.2(Thickness of the sheet) |
- |
0 |
|
- |
| 4.3(Classifications) |
- |
0 |
|
- |
| 4.3(Core Thickness for 3-ply Construction
(asper IS15960)) |
- |
0 |
|
- |
| 4.3(Thickness of protective layer (as per IS 15960)) |
- |
0 |
|
- |
| 4.4(Thickness of 3ply full body utensil) |
- |
0 |
|
- |
| 5(Workmanship and finish) |
- |
0 |
|
- |
| 5.4(Handles) |
- |
0 |
|
- |
| 4.1 of IS 13395(Construction) |
- |
0 |
|
- |
| 4.2 of IS 13395(Materials) |
- |
0 |
|
- |
| 4.3 of IS 13395(Selection and Size) |
- |
0 |
|
- |
| 4.4 of Is 13395(Position of Handle and Knob with Respect to Cookware) |
- |
0 |
|
- |
| 4.5 of IS 13395(Attachment to Cookware) |
- |
0 |
|
- |
| 5.2 of IS 13395(Bending Strength) |
- |
0 |
|
- |
| 5.3 of IS 13395(Torque Strength) |
- |
0 |
|
- |
| 5.4 of IS 13395(Impact Strength) |
- |
0 |
|
- |
| 5.5 of IS 13395(Fatigue Resistance
15 000 cycles withstand) |
- |
0 |
|
- |
| 5.6 of IS 13395(Leakage) |
- |
0 |
|
- |
| 5.7 of IS 13395(Thermal Insulation) |
- |
0 |
|
- |
| 5.8 of IS 13395(Heat Resistance) |
- |
0 |
|
- |
| 5.9 of IS 13395(Washing Resistance) |
- |
0 |
|
- |
| 5.10 of IS 13395(Burning Resistance) |
- |
0 |
|
- |
| 5.5(Material comes in contact with food) |
- |
0 |
|
- |
| 6.1(Staining Test) |
- |
0 |
|
- |
| 6.2(Mechanical Shock Test) |
- |
0 |
|
- |
| 6.3(Thermal Shock Test) |
- |
0 |
|
- |
| 6.4(Dry Heat Test) |
- |
0 |
|
- |
| 6.6(Heat test) |
- |
0 |
|
- |
| 6.7.1(Nominal Capacity Test) |
- |
0 |
|
- |
| 6.7.2(Internal diameter of utensil) |
- |
0 |
|
- |
| Annex C(Test for leaching) |
- |
0 |
|
- |
| Annex C(Sensorial test) |
- |
0 |
|
- |
|
08 Feb, 2027 |
- included w.e.f 26.11.2025 |
| 3184 |
RTRC LIMITED, GURUGRAM
| 9177406
| IS 2465 (1984) |
Specification for cables for motor vehicles (Second Revision) |
specification for cables for motor vehicles |
28350 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Insulation) |
- |
200 |
|
- |
| 7.3(Insulation) |
- |
200 |
|
- |
| 8(Core Identification) |
- |
200 |
|
- |
| 9(Laying up of cores) |
- |
200 |
|
- |
| 10.1.1(Sheathing ) |
- |
200 |
|
- |
| 10.2(Sheathing ) |
- |
0 |
|
- |
| 3 & 6(Flexibility class) |
- |
200 |
|
- |
| 3 & 6(Construction) |
- |
200 |
|
- |
| 3 & 6(Diameter of wire(mm)) |
- |
1000 |
|
- |
| 3 & 6(Annealing test) |
- |
500 |
|
- |
| 3 & 6(Persulphate Test) |
- |
1000 |
|
- |
| 3 & 6(Conductor resistance Test (ohm/km at 20˚c)) |
- |
1000 |
|
- |
| 7.2, 10.3, 11(Dimensions & thickness ) |
- |
200 |
|
- |
| 7.2, 10.3, 11(Dimensions & thickness ) |
- |
0 |
|
- |
| 7.2, 10.3, 11(Overall Dimension (mm)) |
- |
0 |
|
- |
| 4.2 & 12.1(Without Ageing For Insulation
Tensile Strength (N/mm²)) |
- |
500 |
|
- |
| 4.2 & 12.1, (f), 1(elongation at break (N/mm²)) |
- |
0 |
|
- |
| 4.2 & 12.1, (f), 1(Tensile Strength at break (N/mm²)) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 1(elongation test at break) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 1(Tensile strength at break) |
- |
0 |
|
- |
| 4.2 & 12.1, (f), 2(Ageing in air oven) |
- |
2500 |
|
- |
| 4.2 & 12.1, (f), 3(Ageing in oxygen bomb) |
- |
1000 |
|
- |
| 4.2 & 12.1, (e), 2(After Ageing in air oven) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 3(Loss of mass test (mg/cm²) of Insulation) |
- |
1000 |
|
- |
| 4.2 & 12.1, (e), 3(Loss of mass test (mg/cm²) of Sheath) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 4(Hot deformation test (%) of Insulation) |
- |
1000 |
|
- |
| 4.2 & 12.1, (e), 4(Hot deformation test (%) of Sheath) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 5(Heat Shock Test of Insulation) |
- |
1000 |
|
- |
| 4.2 & 12.1, (e), 5(Heat Shock Test of Sheath) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 6(Shrinkage Test (%) of Insulation) |
- |
500 |
|
- |
| 4.2 & 12.1, (e), 6(Shrinkage Test (%) of Sheath) |
- |
0 |
|
- |
| 14(High Voltage Test) |
- |
3500 |
|
- |
| 15(SPARK TEST FOR SINGLE CORE GENERAL WIRING CABLES) |
- |
1000 |
|
- |
| 16.1(CAPACITANCE TEST FOR PVC INSULATION IGNITION CABLE) |
- |
1000 |
|
- |
| 17.1(OZONE RESISTANCE TEST FOR IGNITION CABLES) |
- |
2000 |
|
- |
| 18.1(EFFECT OF HEAT ON FLEXIBILITY FOR IGNITION CABLES) |
- |
0 |
|
- |
| 19.1(EFFECT OF OIL ON IGNITION CABLES) |
- |
1000 |
|
- |
| 19.2(EFFECT OF OIL ON IGNITION CABLES) |
- |
0 |
|
- |
| 20.3(EFFECT OF LUBRICATING OIL) |
- |
0 |
|
- |
| 20.3(EFFECT OF LUBRICATING OIL) |
- |
0 |
|
- |
| 20.3(EFFECT OF BRAKE FLUID) |
- |
1000 |
|
- |
| 20.3(EFFECT OF BRAKE FLUID) |
- |
0 |
|
- |
| 20.3(EFFECT OF DIESEL) |
- |
500 |
|
- |
| 20.3(EFFECT OF DIESEL) |
- |
0 |
|
- |
| 20.3(Increase in average diameter %) |
- |
0 |
|
- |
| 20.3(Wrapping test) |
- |
250 |
|
- |
| 21.1(EFFECT OF COOLING ON FLEXIBILITY) |
- |
500 |
|
- |
| 21.2(EFFECT OF COOLING ON FLEXIBILITY) |
- |
0 |
|
- |
| 21.2(EFFECT OF COOLING ON FLEXIBILITY) |
- |
0 |
|
- |
| 22.1(FLAMMABILITY TEST) |
- |
3000 |
|
- |
| 22.1(FLAMMABILITY TEST) |
- |
0 |
|
- |
| 23.1(Manufacturer's Identification) |
- |
0 |
|
- |
| 23.1(Manufacturer's Identification) |
- |
0 |
|
- |
| 24.1(PACKING AND MARKING) |
- |
0 |
|
- |
| 24.2(PACKING AND MARKING) |
- |
0 |
|
- |
| 24.2.1(PACKING AND MARKING) |
- |
0 |
|
- |
| 12.1.b(Persulphate test (when
applicable)) |
- |
1000 |
|
- |
| 6.1, 12.3, 12.1.c(Conductor Resistance) |
- |
0 |
|
- |
| 12.1.e4(Hot deformation) |
- |
1000 |
|
- |
| 12.1.e5(Heat Shock) |
- |
0 |
|
- |
| CL.12.1 (e) 2(Tensile Strength After Ageing) |
- |
0 |
|
- |
| CL.12.1 (e) 2(Elongation After Ageing) |
- |
0 |
|
- |
| CL.12.1 (e) 2(Tensile Strength Variation) |
- |
0 |
|
- |
| CL.12.1 (e) 2(Elongation Variation) |
- |
0 |
|
- |
| CL.12.1 (e) 2(Elongation Variation) |
- |
0 |
|
- |
| Cl.12 (e) 5(Heat shock test) |
- |
0 |
|
- |
| Cl.12 (e) 4(Hot Deformation Test) |
- |
0 |
|
- |
| Cl.12 (e) 6(Shrinkage Test) |
- |
0 |
|
- |
| Cl.12 (e) 6(Shrinkage Test (Cracks Observed)) |
- |
0 |
|
- |
| Cl. 12.1 (e) 3(Loss of Mass Insulation) |
- |
1000 |
|
- |
|
03 Apr, 2027 |
- Included w.e.f 29.09.2025 |
| 3185 |
RTRC LIMITED, GURUGRAM
| 9177406
| IS 9567 (2001) |
Tin or tin - Lead coated copper wire - Specificaiton (First Revision) |
Tin or tin-lead coated copper wire — specification |
15400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Material) |
- |
0 |
|
- |
| 4.2(Resistivity) |
- |
1000 |
|
- |
| 4.3(Details of Coating) |
- |
0 |
|
- |
| 4.4(Diameter of Coated Wire) |
- |
2000 |
|
- |
| 5(Packing and Marking) |
- |
0 |
|
- |
| 6.3.1(Resistance Test) |
- |
1000 |
|
- |
| 6.4.1(Measurement of Diameter) |
- |
1000 |
|
- |
| 6.4.2(Elongation and Breaking Strength Test) |
- |
2000 |
|
- |
| 6.4.3(Bend Test) |
- |
1000 |
|
- |
| 6.4.4(Solderability Test) |
- |
1000 |
|
- |
| 6.4.5(Continuity of Coating Test) |
- |
1000 |
|
- |
| 6.4.6(Adherence of Coating Test) |
- |
1000 |
|
- |
|
03 Apr, 2027 |
- Included w.e.f 29.09.2025 |
| 3186 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 996 (2025) |
SINGLE PHASE ac INDUCTION MOTORS FOR GENERAL PURPOSE (Fouth Revision) |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-7(Dimensions) |
- |
2000 |
|
- |
| Cl-9.1(Mounting) |
- |
2000 |
|
- |
| Cl-9.2(Terminal Box) |
- |
2000 |
|
- |
| Cl-9.3(Mounting Constructions) |
- |
2000 |
|
- |
| Cl-9.3(Mounting Constructions) |
- |
2000 |
|
- |
| Cl-9.4(Constructional Features) |
- |
2000 |
|
- |
| Cl-9.5(Earthing) |
- |
2000 |
|
- |
| Cl-10.1(Enclosures) |
- |
2000 |
|
- |
| Cl-12.1(Torques) |
- |
2000 |
|
- |
| Cl-12.1.2(Momentary overload test) |
- |
2000 |
|
- |
| Cl-12.2(Temperature Rise) |
- |
2000 |
|
- |
| Cl-12.3(Short Time Rating) |
- |
2000 |
|
- |
| Cl-12.4(Method of Testing) |
- |
2000 |
|
- |
| Cl-12.5(Performance Values) |
- |
2000 |
|
- |
| Cl-12.6(Limits of Vibration Severity) |
- |
2000 |
|
- |
| Cl-12.7(Insulation Resistance) |
- |
2000 |
|
- |
| Cl-13.1(High Voltage Values) |
- |
2000 |
|
- |
| Cl-13.2(Moisture Proofness) |
- |
2000 |
|
- |
| Cl-13.3(Leakage Current) |
- |
2000 |
|
- |
| Cl-14(Winding Resistance Measurement) |
- |
2000 |
|
- |
| Cl-15(REDUCED VOLTAGE RUNNING UP TEST AT NO LOAD) |
- |
2000 |
|
- |
| Cl-16(NOISE LEVEL) |
- |
2000 |
|
- |
| Cl-17(OVER SPEED TEST) |
- |
2000 |
|
- |
| Cl-18(TERMINAL MARKING) |
- |
2000 |
|
- |
| Cl-12.1.1(Test for torues at rated voltage and frequency) |
- |
2000 |
|
- |
| Cl-12.1.1(Pull up Torque at rated voltage and frequency) |
- |
2000 |
|
- |
| Cl-12.1.1(Test for breakaway starting current at rated voltage and frequency) |
- |
2000 |
|
- |
| Cl-12.1.2(Breakaway (starting) torque at rated voltage and frequency) |
- |
2000 |
|
- |
| Cl-12.5.1(Test for full-load performance at rated voltage and frequency) |
- |
2000 |
|
- |
| Cl-21.5(Acceptance Tests) |
- |
2000 |
|
- |
| Cl-7(Dimensions) |
- |
2000 |
|
- |
| Cl-9.1(Mounting) |
- |
2000 |
|
- |
| Cl-9.2(Terminal Box) |
- |
2000 |
|
- |
| Cl-9.3(Mounting Constructions) |
- |
2000 |
|
- |
| Cl-9.3(Mounting Constructions) |
- |
2000 |
|
- |
| Cl-9.4(Constructional Features) |
- |
2000 |
|
- |
| Cl-9.5(Earthing) |
- |
2000 |
|
- |
| Cl-10.1(Enclosures) |
- |
2000 |
|
- |
| Cl-12.1(Torques) |
- |
2000 |
|
- |
| Cl-12.1.2(Momentary overload test) |
- |
2000 |
|
- |
| Cl-12.2(Temperature Rise) |
- |
2000 |
|
- |
| Cl-12.3(Short Time Rating) |
- |
2000 |
|
- |
| Cl-12.4(Method of Testing) |
- |
2000 |
|
- |
| Cl-12.5(Performance Values) |
- |
2000 |
|
- |
| Cl-12.6(Limits of Vibration Severity) |
- |
2000 |
|
- |
| Cl-12.7(Insulation Resistance) |
- |
2000 |
|
- |
| Cl-13.1(High Voltage Values) |
- |
2000 |
|
- |
| Cl-13.2(Moisture Proofness) |
- |
2000 |
|
- |
| Cl-13.3(Leakage Current) |
- |
2000 |
|
- |
| Cl-14(Winding Resistance Measurement) |
- |
2000 |
|
- |
| Cl-15(REDUCED VOLTAGE RUNNING UP TEST AT NO LOAD) |
- |
2000 |
|
- |
| Cl-16(NOISE LEVEL) |
- |
2000 |
|
- |
| Cl-17(OVER SPEED TEST) |
- |
2000 |
|
- |
| Cl-18(TERMINAL MARKING) |
- |
2000 |
|
- |
| Cl-12.1.1(Test for torues at rated voltage and frequency) |
- |
2000 |
|
- |
| Cl-12.1.1(Pull up Torque at rated voltage and frequency) |
- |
2000 |
|
- |
| Cl-12.1.1(Test for breakaway starting current at rated voltage and frequency) |
- |
2000 |
|
- |
| Cl-12.1.2(Breakaway (starting) torque at rated voltage and frequency) |
- |
2000 |
|
- |
| Cl-12.5.1(Test for full-load performance at rated voltage and frequency) |
- |
2000 |
|
- |
| Cl-21.5(Acceptance Tests) |
- |
2000 |
|
- |
|
14 Nov, 2027 |
- Included w.e.f. 09.10.2025 |
| 3187 |
Hi Physix Laboratory India Private Limited, Pune
| 7126926
| IS/IEC 61730 : PART 1 (2023) |
Photovoltaic (PV) Module Safety Qualification Part 1 Requirements for Construction (Second Revision) |
- |
396000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Classification, applications and intended use) |
- |
5000 |
|
- |
| 6.2(Marking and documentation) |
- |
10000 |
|
- |
| 6.3.2(Internal wiring) |
- |
15000 |
|
- |
| 6.3.3(External wiring and cables) |
- |
15000 |
|
- |
| 6.3.4(Module overcurrent protection rating) |
- |
15000 |
|
- |
| 6.3.5(Connectors) |
- |
15000 |
|
- |
| 6.3.6(Junction boxes) |
- |
15000 |
|
- |
| 6.3.7(Frontsheets and backsheets) |
- |
15000 |
|
- |
| 6.3.8(Insulation barriers) |
- |
10000 |
|
- |
| 6.3.9(Electrical connections) |
- |
15000 |
|
- |
| 6.3.10(Encapsulants) |
- |
15000 |
|
- |
| 6.3.11(Bypass diodes) |
- |
15000 |
|
- |
| 6.4(Mechanical and electromechanical connections) |
- |
15000 |
|
- |
| 6.4.2(Screw connections) |
- |
10000 |
|
- |
| 6.4.3(Rivets) |
- |
10000 |
|
- |
| 6.4.4(Thread-cutting screws) |
- |
10000 |
|
- |
| 6.4.5(Form/press/tight fit) |
- |
15000 |
|
- |
| 6.4.6(Connections by adhesives) |
- |
15000 |
|
- |
| 6.4.7(Other connections) |
- |
15000 |
|
- |
| 6.5.2(Polymeric materials) |
- |
15000 |
|
- |
| 6.5.2.3(Flammability) |
- |
15000 |
|
- |
| 6.5.3.2(Current-carrying parts) |
- |
15000 |
|
- |
| 6.5.4(Adhesives) |
- |
15000 |
|
- |
| 6.6.2(Protection against accessibility to hazardous live parts) |
- |
10000 |
|
- |
| 6.6.3(Insulation coordination) |
- |
15000 |
|
- |
| 6.6.3.2.1(Pollution degree) |
- |
5000 |
|
- |
| 6.6.3.3(Creepage distance) |
- |
8000 |
|
- |
| 6.6.3.4(Clearance) |
- |
8000 |
|
- |
| 6.6.4(Distance through functional and relied upon insulation) |
- |
15000 |
|
- |
| 6.6.4.3(Cemented joints) |
- |
10000 |
|
- |
| 6.6.4.4(Distance through functional insulation) |
- |
15000 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f.10.09.2025 |
| 3188 |
ALPHA TEST HOUSE PVT LTD, BAHADURGARH
| 8185306
| IS 16090 (2013) |
Geo-synthetics – Geo-textiles used as protection (or cushioning) materials – Specification |
All |
150000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.4, Table 1, (i)(Mass per unit area, g/m2) |
- |
2000 |
|
- |
| 4.4, Table 1, (ii)(Tensile strength, kN/m) |
- |
2000 |
|
- |
| 4.4, Table 1, (iii)(Trapezoidal tear strength, kN) |
- |
2000 |
|
- |
| 4.5, Table 1, (iv)(CBR puncture resistance, kN) |
- |
2000 |
|
- |
| 4.6, Table 1, (v)(Maximum UV resistance (after 500 h exposure), percent) |
- |
2000 |
|
- |
| 6.2(Sampling) |
- |
2000 |
|
- |
| 7(Packing) |
- |
2000 |
|
- |
| 9.1(Identification) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class I(Mass per unit area, g/m2) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class I(Tensile strength, kN/m) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class I(Trapezoidal tear strength, kN) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class I(CBR puncture resistance, kN) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class I(Maximum UV resistance (after 500 h exposure), percent) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class II(Mass per unit area, g/m2) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class II(Tensile strength, kN/m) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class II(Trapezoidal tear strength, kN) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class II(Trapezoidal tear strength, kN) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class II(CBR puncture resistance, kN) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class II(Maximum UV resistance (after 500 h exposure), percent) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class III(Mass per unit area, g/m2) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class III(Tensile strength, kN/m) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class III(Trapezoidal tear strength, kN) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class III(CBR puncture resistance, kN) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class III(Maximum UV resistance (after 500 h exposure), percent) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class IV(Mass per unit area, g/m2) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class IV(Tensile strength, kN/m) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class IV(Trapezoidal tear strength, kN) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class IV(CBR puncture resistance, kN) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class IV(Maximum UV resistance (after 500 h exposure), percent) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class V(Mass per unit area, g/m2) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class V(Tensile strength, kN/m) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class V(Trapezoidal tear strength, kN) |
- |
2000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class V(CBR puncture resistance, kN) |
- |
4000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class V(Maximum UV resistance (after 500 h exposure), percent) |
- |
4000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class VI(Mass per unit area, g/m2) |
- |
4000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class VI(Tensile strength, kN/m) |
- |
4000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class VI(Trapezoidal tear strength, kN) |
- |
4000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class VI(CBR puncture resistance, kN) |
- |
4000 |
|
- |
| Table 1, Clauses 4.4, 4.5, 4.6 and 6.4, Class VI(Maximum UV resistance (after 500 h exposure), percent) |
- |
4000 |
|
- |
| 4.3(Carbon black content and carbon black dispersion test) |
- |
4000 |
|
- |
|
08 May, 2028 |
- Included w.e.f.29.09.2025 |
| 3189 |
EMC Testing and Compliance LLP, Gurugram
| 8141526
| IS 11951 (2024) |
PUMPSET FOR DIRECT EVAPORATIVE AIR COOLER â SPECIFICATION (Second Revision) |
- |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.1(Non-Submersible Pumpset) |
- |
2000 |
|
- |
| 5.1.2(Submersible Pumpset) |
- |
2000 |
|
- |
| 6.1, 7.3, 9.1, 9.4.2, Table-1(Discharge Head, m) |
- |
2000 |
|
- |
| 6.1, 7.3, 9.1, 9.4.2,Table-1(Minimum Discharge, l/min) |
- |
2000 |
|
- |
| 6.1, 7.3, 9.1, 9.4.2, Table-1(Type 1 Motor Wattage) |
- |
2000 |
|
- |
| 6.1, 7.3, 9.1, 9.4.2, Table-1(Type 2 Motor Wattage) |
- |
2000 |
|
- |
| 6.1, 7.3, 9.1, 9.4.2, Table-2(Motor Wattage) |
- |
2000 |
|
- |
| 6.1, 7.3, 9.1,9.4.2, Table-2(Minimum Discharge Head, Hd) |
- |
2000 |
|
- |
| 6.1, 7.3, 9.1, 9.4.2,Table-2(Discharge Measurement Height, h) |
- |
2000 |
|
- |
| 6.1, 7.3, 9.1, 9.4.2, Table-2(Minimum, Discharge*) |
- |
2000 |
|
- |
| Cl-8(GENERAL REQUIREMENTS) |
- |
10000 |
|
- |
| 9.2(Tests on motor) |
- |
10000 |
|
- |
| 9.3(Water Requirement) |
- |
1000 |
|
- |
| 9.4.1(Reliability Tests) |
- |
1000 |
|
- |
| 9.4.3(Ingress protection test) |
- |
5000 |
|
- |
| 9.4.6(Dry Run Test) |
- |
5000 |
|
- |
| 9.5(Routine Test) |
- |
8000 |
|
- |
| 9.6(Type Test) |
- |
15000 |
|
- |
| 9.7(Leakage current and electric strength at operating temperature) |
- |
5000 |
|
- |
| 9.7(Moisture resistance) |
- |
5000 |
|
- |
| 9.7(Leakage current and electric strength) |
- |
5000 |
|
- |
|
19 Jul, 2027 |
- Included w.e.f. 24.12.2025 |
| 3190 |
Central Institute of Petrochemicals Engineering & Technology (CIPET), Murthal
| 9121934
| IS 14887 (2014) |
Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sacks for packaging of 50 kg food grains – Specification (first revision) |
50 Kg |
21430 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2(Tapes – Width and Thickness
( IS 6192/IS 11197)) |
- |
500 |
|
Nil |
| 3.2(Tapes – Linear Density
(IS 6192/IS 11197)) |
- |
700 |
|
Nil |
| 3.2(Tapes – Tenacity (IS 6192/IS 11197)) |
- |
1100 |
|
Nil |
| 3.2(Tapes – Elongation at point of rupture
(IS 6192/IS 11197)) |
- |
1100 |
|
Nil |
| 3.2(Tapes – Heat Shrinkage (HDPE) (Cl. 3.2 and IS 6192)) |
- |
700 |
|
Nil |
| 3.2(Tapes – Dimensional stability (PP)
(IS 11197)) |
- |
700 |
|
Nil |
| 3.2(Unlaminated Fabric Mass ) |
- |
500 |
|
Nil |
| 3.3.1(Bottom seam (IS 10789)) |
- |
1100 |
|
Nil |
| 4.1 and 3.4(Mass of bale (Cl. 4.1), Capacity (Cl 3.4)) |
- |
500 |
|
Nil |
| 4.2 and Table 1 ii(Dimensions ) |
- |
500 |
|
Nil |
| 5.2 and Table 1 iii(Ends per dm ) |
- |
500 |
|
Nil |
| 5.2 and Table 1 iv(Picks per dm ) |
- |
0 |
|
Ends & Picks including both test Charges is Rs. 250 |
| 4.2 and Table 1 v(Mass of sack ) |
- |
500 |
|
Nil |
| 4.2 and Table 1 vi(Average breaking strength of fabric ) |
- |
1100 |
|
U.V light Exposure Test Charges Rs. 10180 |
| 4.2 and Table 1 vi(Breaking strength of bottom seam ) |
- |
1100 |
|
Nil |
| 4.2 and Table 1 viii(Elongation at break of fabric ) |
- |
0 |
|
Charge for the same is included with Breaking strength of fabric charges |
| 4.2 and Table 1 ix(Average breaking strength and elongation at break of UV stabilized HDPE/PP fabric after been exposed to UV radiation and weathering ) |
- |
1100 |
|
Nil |
| 4.2 and Table 1 x(Ash content ) |
- |
950 |
|
Nil |
| 3.2(Tapes – Width and Thickness
( IS 6192/IS 11197)) |
- |
500 |
|
Nil |
| 3.1(Material Identification) |
- |
1050 |
|
Test Method-Chemical Analysis |
| 3.1(Overall Migration) |
- |
1700 |
|
Overall Migration Distilled water/10 days/40°C
Specimen Charges Rs. 625 |
| 3.2(Density) |
- |
500 |
|
Nil |
| 3.2(MFI) |
- |
1100 |
|
Nil |
|
09 Aug, 2028 |
- - |
| 3191 |
Central Institute of Petrochemicals Engineering & Technology (CIPET), Murthal
| 9121934
| IS 11652 (2017) |
Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sacks for packaging of 50 kg cement – Specification (third revision) |
- |
27680 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2
(width of tape, 2.5 mm ± 0.1 mm) |
- |
500 |
|
Nil |
| Fig. 1- Table 1- Sr. no. ii
(Ends per dm - Annex B 40 ± 2 ) |
- |
500 |
|
Nil |
| Fig. 1- Table 1-Sr. no. iii
(Picks per dm-Annex B 40 ± 2 ) |
- |
0 |
|
Test Charges Included in Ends Test |
| Fig. 1- Table 1- Sr. no. i
(Dimensions, mm (see Note )- Annex B
c) Width of gusset (e) 76 ± 10 mm
) |
- |
500 |
|
Nil |
| Fig. 1- Table 1- Sr. no. i
(Dimensions, mm (see Note ) -Annex B
d) Width of valve (v) 100, + 10/-5 mm
) |
- |
0 |
|
Test Charges Included in Dimension Test |
| Fig. 1- Table 1-Sr. no. i
(Dimensions, mm (see Note )- Annex B
b) Width of sack (w) 480 ± 10 mm
) |
- |
0 |
|
Test Charges Included in Dimension Test |
| Fig. 1, Table 1
(i) Dimensions, mm (see Note ) -Annex B
a) Length of sack, inside (l), 710 ± 10 mm
) |
- |
0 |
|
Test Charges Included in Dimension Test |
| 4.5(and the remaining overhang shall not be more than 5 mm after trimming.) |
- |
0 |
|
Test Charges Included in Dimension Test |
| 4.1(Raw Material
) |
- |
2000 |
|
Nil |
| 4.2
(Linear Density, 900 denier) |
- |
500 |
|
Nil |
| 4.2
(The woven fabric shall be
of mesh, 10 × 10 per inch) |
- |
500 |
|
Nil |
| 4.2
(The woven fabric shall be
of weight, 79 g/m2 ) |
- |
500 |
|
Nil |
| 4.3(Sacks) |
- |
500 |
|
Nil |
| 4.4(Seam
) |
- |
500 |
|
Nil |
| 4.4(Seam The two rows of stitches shall be separated from each other by minimum 5 mm and ) |
- |
0 |
|
Test Charges Included in Seam Test |
| 4.4(Seam The outer stitch shall be minimum 8 mm from the outer edge of the sacks. ) |
- |
0 |
|
Test Charges Included in Seam Test |
| 4.4(Seam The stitching shall be done with double fold over seam to) |
- |
0 |
|
Test Charges Included in Seam Test |
| 4.4(to a depth of minimum 25 mm, so that so that) |
- |
0 |
|
Test Charges Included in Seam Test |
| 4.4(that the stitches pass through a minimum of six layers of the fabric.) |
- |
0 |
|
Test Charges Included in Seam Test |
| 4.4(The number of stitches/dm shall be 14 ± 2.) |
- |
0 |
|
Test Charges Included in Seam Test |
| 4.6(Capacity The sack shall have the nominal filling capacity of 50 kg) |
- |
500 |
|
Nil |
| 4.7(Valve for Filling of Sacks) |
- |
500 |
|
Nil |
| 5/5.1-Table 1-Sr. no. iv(Requirements, Mass of Sack- IS 1964
a) gusseted type 71 + 6%) |
- |
0 |
|
Nil |
| 5/5.3-Table 1-Sr. no.v(Average breaking strength of fabric [Ravelled strip method, 325 mm × 70 mm] Min, N(kgf): -1969 (Part 1) a) Lengthwise , 900 (91.8) ) |
- |
1100 |
|
Nil |
| 5/5.3-Table 1-Sr. no.v(Average breaking strength of fabric [Ravelled strip method, 325 mm × 70 mm] Min, N(kgf): - 1969 (Part 1) b) Widthwise , 900 (91.8) ) |
- |
1100 |
|
Nil |
| 5/5.3-Table 1-Sr. no.vi(Breaking strength of top seam (Ravelled strip method), Min, - IS 9030 N (kgf) 400 (40.8)) |
- |
1100 |
|
Nil |
| 5/5.3-Table 1-Sr. no.vi(Breaking strength of bottom seam (Ravelled strip method), Min, - IS 9030 N (kgf) 400 (40.8)) |
- |
1100 |
|
Nil |
| 5/5.3-Table 1-Sr. no.vii(Elongation at break of fabric (Ravelled strip method), percent : - IS 1969 (Part1 ) a) Lengthwise 15 to 25) |
- |
0 |
|
Charges included in Breaking Strength |
| 5/5.3-Table 1-Sr. no.vii(Elongation at break of fabric (Ravelled strip method), percent : - IS 1969 (Part1 ) b) Widthwise 15 to 25) |
- |
0 |
|
Charges included in Breaking Strength |
| 5/5.4-Table 1-Sr. no.viii(Drop impact strength - Annex C No failure) |
- |
1100 |
|
Nil |
| 5/5.5-Table 1-Sr. no.viii(Ash content Max percent- Annex D a) For UV stabilized sacks 2.2
) |
- |
1200 |
|
Nil |
| 5/5.5-Table 1-Sr. no.viii(Ash content Max percent- Annex D b) For non-UV stabilized sacks 6
) |
- |
1200 |
|
Nil |
| 5/5.6 (UV Resistance, ) |
- |
10180 |
|
Nil |
| 5/5.6 (UV Resistance, The UV stabilized woven fabric shall have at least 50 percent retention of the original breaking strength when tested after the same has been exposed
to a) UV Radiation -Annex F ) |
- |
1100 |
|
Nil |
| 5/5.6 (UV Resistance, The UV stabilized woven fabric shall have at least 50 percent retention of the original breaking strength when tested after the same has been exposed
to b) Accelerated Weathering - Annex F ) |
- |
1100 |
|
Nil |
| 4.5(Lamination ) |
- |
500 |
|
Nil |
| 4.2
(Fabric) |
- |
500 |
|
- |
|
09 Aug, 2028 |
- - |
| 3192 |
Central Institute of Petrochemicals Engineering & Technology (CIPET), Murthal
| 9121934
| IS 14252 (2015) |
Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sack for filling sand – Specification (second revision) |
- |
21690 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Raw Material) |
- |
2000 |
|
Nil |
| 3.2(Tapes – Width
) |
- |
500 |
|
Nil |
| 3.2(Tapes – Linear Density
) |
- |
500 |
|
Nil |
| 3.3(Tying Cord) |
- |
500 |
|
Nil |
| 3.4(Sack) |
- |
500 |
|
Nil |
| 3.4.1(Seam) |
- |
500 |
|
Nil |
| 4.1 and Table 1 i a(Dimensions Outside Length) |
- |
500 |
|
Nil |
| 4.1 and Table 1 i b(Dimensions Outside Width) |
- |
500 |
|
Nil |
| 4.1 and Table 1 ii(Ends per dm ) |
- |
500 |
|
Nil |
| 4.1 and Table 1 iii(Picks per dm ) |
- |
0 |
|
Test Charges included in Ends per dm |
| 4.2 and Table 1 iv(Mass of sack
) |
- |
500 |
|
Nil |
| 4.1 and Table 1 v a(Average breaking strength of fabric Warpway
) |
- |
1100 |
|
Nil |
| 4.1 and Table 1 v b(Average breaking strength of fabric Weftway
) |
- |
1100 |
|
Nil |
| 4.1 and Table 1 vi(Average Breaking strength of bottom seam ) |
- |
1100 |
|
Nil |
| 4.1 and Table 1 vii a(Elongation at break of fabric Lengthwise) |
- |
0 |
|
Test Charges included in Breaking strength |
| 4.1 and Table 1 vii b(Elongation at break of fabric Widthwise ) |
- |
0 |
|
Test Charges included in Breaking strength |
| 4.1 and Table 1 viii(Average breaking strength and elongation at break of UV stabilized HDPE/PP fabric after been exposed to UV radiation and weathering ) |
- |
12540 |
|
UV light exposure Rs. 10340
Breaking strength (warp & weft) |
| 4.1 and Table 1 ix(Ash content ) |
- |
1200 |
|
Nil |
| 3.2 (Mesh size and weight is g/cm2) (amendment 3)(Mesh size and weight is g/cm2) |
- |
500 |
|
- |
|
09 Aug, 2028 |
- - |
| 3193 |
Alpha Test House Services LLP (160), Sahibzada Ajit Singh Nagar
| 9138706
| IS 4409 (2023) |
FERRONICKEL -- SPECIFICATION |
FeNi20,30,40,50,70 |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4.1, 4.2, 7.1, 7.2, Table-1 and Annex.-B(Nickel, % by mass, IS 17320:2020) |
- |
20000 |
|
- |
| Cl. 4.1, 4.2, 7.1, 7.2, Table-2 and Annex.-B(Silicon, % by mass, IS 17321:2020) |
- |
20000 |
|
- |
| Cl. 4.1, 4.2, 7.1, 7.2, Table-2 and Annex.-B(Sulphur, % by mass, IS 17322:2020) |
- |
20000 |
|
- |
| Cl. 4.1, 4.2, 7.1, 7.2, Table-1 and Annex.-B(Carbon, % by mass, IS 228(P-1):1987) |
- |
20000 |
|
- |
| Cl. 4.1, 4.2, 7.1, 7.2, Table-1 and Annex.-B(Phosphorus, % by mass, IS: 1559 (P-4):1982) |
- |
20000 |
|
- |
| Cl. 4.2, 7.1, 7.2, Table-2, Annex-B(Manganese, % by mass, IS 17835:2020) |
- |
20000 |
|
- |
| Cl. 4.2, 7.1, 7.2, Table-2, Annex-B(Copper, % by mass, IS 17835:2020) |
- |
20000 |
|
- |
| Cl. 4.2, 7.1, 7.2, Table-1, Annex.-B(Cobalt, % by mass, IS 17325:2020) |
- |
20000 |
|
- |
| Cl. 4.2, 7.1, 7.2, Table-2, Annex-B(Chromium, % by mass, IS 17835:2020) |
- |
20000 |
|
- |
| Cl. 4.2, 7.1, 7.2, Table-2, Annex.-B(Arsenic, % by mass) |
- |
20000 |
|
- |
| Cl. 4.2, 7.1, 7.2, Table-2, Annex.-B(Bismuth, % by mass) |
- |
20000 |
|
- |
| Cl. 4.2, 7.1, 7.2, Table-2, Annex.-B(Lead, % by mass) |
- |
20000 |
|
- |
| Cl. 4.2, 7.1, 7.2, Table-2, Annex.-B(Antimony, % by mass, IS 17325:2020) |
- |
20000 |
|
- |
| Cl. 4.2, 7.1, 7.2, Table-2, Annex.-B(Tin, % by mass, IS 17325:2020) |
- |
20000 |
|
- |
|
31 Dec, 2026 |
- - |
| 3194 |
Fire Test & Research Laboratory, Sonipat
| 8123835
| IS 884 (2025) |
First-Aid Hose-Reel for Fire Fighting - Specification (Second Revision) |
First Aid Hose Reel For Fire Fighting |
24000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4(Dimensions) |
- |
1500 |
|
- |
| Cl. 7(PERFORMANCE REQUIREMENT) |
- |
15000 |
|
- |
| Cl. 7.1(Hydrostatic pressure test) |
- |
5000 |
|
- |
| Cl. 7.2(Resistance to leakage) |
- |
5000 |
|
- |
| Cl. 7.3(Strength) |
- |
5000 |
|
- |
| Cl. 7.3.1(Impact resistance test) |
- |
2500 |
|
- |
| Cl. 7.3.2(Load Resistance Test) |
- |
3000 |
|
- |
| Cl. 7.4(Range and Water flow rate) |
- |
2500 |
|
- |
| Cl. 7.5(Swinging Arrangement) |
- |
500 |
|
- |
| Cl. 7.6(Reel Action) |
- |
500 |
|
- |
| Cl. 8(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| Cl. 8.2(Painting) |
- |
500 |
|
- |
| Cl. 7.7(Resistance to impact test for nozzle) |
- |
2000 |
|
- |
| Cl. 7.8("Ageing test for plastic made
nozzle") |
- |
4000 |
|
- |
| Cl. 7.9("Resistance to external corrosion
test") |
- |
4000 |
|
- |
| Cl. 6(CONSTRUCTION) |
- |
100 |
|
- |
| Cl. 9(CRITERIA FOR CONFORMITY) |
- |
0 |
|
- |
| Cl. 10(MARKING) |
- |
500 |
|
- |
| Cl. 4(Dimensions) |
- |
0 |
|
Repeat Test |
| Cl. 7(PERFORMANCE REQUIREMENT) |
- |
0 |
|
Repeat Test |
| Cl. 7.1(Hydrostatic pressure test) |
- |
0 |
|
Repeat Test |
| Cl. 7.2(Resistance to leakage) |
- |
0 |
|
Repeat Test |
| Cl. 7.3(Strength) |
- |
0 |
|
Repeat Test |
| Cl. 7.3.1(Impact resistance test) |
- |
0 |
|
Repeat Test |
| Cl. 7.3.2(Load Resistance Test) |
- |
0 |
|
Repeat Test |
| Cl. 7.4(Range and Water flow rate) |
- |
0 |
|
Repeat Test |
| Cl. 7.5(Swinging Arrangement) |
- |
0 |
|
Repeat Test |
| Cl. 7.6(Reel Action) |
- |
0 |
|
Repeat Test |
| Cl. 8(WORKMANSHIP AND FINISH) |
- |
0 |
|
Repeat Test |
| Cl. 8.2(Painting) |
- |
0 |
|
Repeat Test |
| Cl. 7.7(Resistance to impact test for nozzle) |
- |
0 |
|
Repeat Test |
| Cl. 7.8("Ageing test for plastic made
nozzle") |
- |
0 |
|
Repeat Test |
| Cl. 7.9("Resistance to external corrosion
test") |
- |
0 |
|
Repeat Test |
| Cl. 6(CONSTRUCTION) |
- |
0 |
|
Repeat Test |
| Cl. 9(CRITERIA FOR CONFORMITY) |
- |
0 |
|
Repeat Test |
| Cl. 10(MARKING) |
- |
0 |
|
Repeat Test |
| Cl. 4(Dimensions) |
- |
- |
|
- |
| Cl. 7(PERFORMANCE REQUIREMENT) |
- |
- |
|
- |
| Cl. 7.1(Hydrostatic pressure test) |
- |
- |
|
- |
| Cl. 7.2(Resistance to leakage) |
- |
- |
|
- |
| Cl. 7.3(Strength) |
- |
- |
|
- |
| Cl. 7.3.1(Impact resistance test) |
- |
- |
|
- |
| Cl. 7.3.2(Load Resistance Test) |
- |
- |
|
- |
| Cl. 7.4(Range and Water flow rate) |
- |
- |
|
- |
| Cl. 7.5(Swinging Arrangement) |
- |
- |
|
- |
| Cl. 7.6(Reel Action) |
- |
- |
|
- |
| Cl. 8(WORKMANSHIP AND FINISH) |
- |
- |
|
- |
| Cl. 8.2(Painting) |
- |
- |
|
- |
| Cl. 7.7(Resistance to impact test for nozzle) |
- |
- |
|
- |
| Cl. 7.8("Ageing test for plastic made
nozzle") |
- |
- |
|
- |
| Cl. 7.9("Resistance to external corrosion
test") |
- |
- |
|
- |
| Cl. 6(CONSTRUCTION) |
- |
- |
|
- |
| Cl. 9(CRITERIA FOR CONFORMITY) |
- |
- |
|
- |
| Cl. 10(MARKING) |
- |
- |
|
- |
|
31 Dec, 2026 |
- Letter may please be approved.
Cl. 5 (MATERIAL) |
| 3195 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 16542 (2016) |
Direct insertion type storage water tank for all glass evacuated tubes solar collector - Specification |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.3(Ideal Heating Test) |
- |
5000 |
|
- |
| 8.2(Leakage Test) |
- |
5000 |
|
- |
| 8.4(Integral Test) |
- |
5000 |
|
- |
| 8.5(Performance Test) |
- |
5000 |
|
- |
| 7.6(Thermal Shock Test for Inner Sealing) |
- |
5000 |
|
- |
| 7.7(Thermal Shock Test for outer Sealing) |
- |
5000 |
|
- |
| 6(GENERAL REQUIREMENTS) |
- |
5000 |
|
- |
| 8.1(Measurement of Storage Water Tank Capacity) |
- |
5000 |
|
- |
| 8.3(Ideal Heating Test) |
- |
5000 |
|
- |
| 8.2(Leakage Test) |
- |
5000 |
|
- |
| 8.4(Integral Test) |
- |
5000 |
|
- |
| 8.5(Performance Test) |
- |
5000 |
|
- |
| 7.6(Thermal Shock Test for Inner Sealing) |
- |
5000 |
|
- |
| 7.7(Thermal Shock Test for outer Sealing) |
- |
5000 |
|
- |
| 6(GENERAL REQUIREMENTS) |
- |
5000 |
|
- |
| 8.1(Measurement of Storage Water Tank Capacity) |
- |
5000 |
|
- |
|
14 Nov, 2027 |
- Included w.e.f. 29.08.2025
Excluding Material as per Clause 5 |
| 3196 |
GLOBAL COMPLIANCE LABORATORY INDIA, GHAZIABAD
| 5172706
| IS 302 : Part 2 : Sec 14 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision) |
- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
3000 |
|
- |
| 6(Classification- IS 302-1) |
- |
3000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.101(Marking) |
- |
3000 |
|
- |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
3000 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
3000 |
|
- |
| 11(Heating, IS 302-1) |
- |
3000 |
|
- |
| 11(Heating, IS 302-1) |
- |
3000 |
|
- |
| 11(Heating, IS 302-1) |
- |
3000 |
|
- |
| 11(Heating, IS 302-1) |
- |
3000 |
|
- |
| 11(Heating, IS 302-1) |
- |
3000 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
3000 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
3000 |
|
- |
| 14(Transient Over Voltages, IS 302-1) |
- |
3000 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
3000 |
|
- |
| 15.2(Moisture Resistance, IS 302-1) |
- |
3000 |
|
- |
| 15(Moisture Resistance, IS 302-1) |
- |
3000 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
3000 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
3000 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
3000 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
3000 |
|
- |
| 19.7(Abnormal Operation, IS 302-1) |
- |
3000 |
|
- |
| 19.8(Abnormal Operation, IS 302-1) |
- |
3000 |
|
- |
| 19.9(Abnormal Operation, IS 302-1) |
- |
3000 |
|
- |
| 19.1(Abnormal Operation, IS 302-1) |
- |
3000 |
|
- |
| 19.101(Abnormal Operation) |
- |
3000 |
|
- |
| 19.102(Abnormal Operation) |
- |
3000 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
3000 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
3000 |
|
- |
| 20.101(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.102(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.103(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.104(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.105(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.106(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.107(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.108(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.109(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.110(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.111(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.112(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.113(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.114(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.115(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.116(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
3000 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
3000 |
|
- |
| 22(Construction, IS 302-1) |
- |
3000 |
|
- |
| 22.101(Construction) |
- |
3000 |
|
- |
| 22.102(Construction) |
- |
3000 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 23.10(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
3000 |
|
- |
| 27(Provision for Earthing, IS 302-1) |
- |
3000 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
3000 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
3000 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
3000 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
3000 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
3000 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
3000 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
3000 |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
3000 |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
3000 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
3000 |
|
- |
| 4(GENERAL REQUIREMENTS) |
- |
3000 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
3000 |
|
- |
| 27(Provision for Earthing) |
- |
3000 |
|
- |
| 29(Clearances, Creepage distances and Solid Insulation) |
- |
3000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3000 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 6(Classification- IS 302-1 ) |
- |
3000 |
|
- |
| 6(Classification- IS 302-1) |
- |
3000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
3000 |
|
- |
| 7.101(Marking) |
- |
3000 |
|
- |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
3000 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
3000 |
|
- |
| 11(Heating, IS 302-1) |
- |
3000 |
|
- |
| 11(Heating, IS 302-1) |
- |
3000 |
|
- |
| 11(Heating, IS 302-1) |
- |
3000 |
|
- |
| 11(Heating, IS 302-1) |
- |
3000 |
|
- |
| 11(Heating, IS 302-1) |
- |
3000 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
3000 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
3000 |
|
- |
| 14(Transient Over Voltages, IS 302-1) |
- |
3000 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
3000 |
|
- |
| 15.2(Moisture Resistance, IS 302-1) |
- |
3000 |
|
- |
| 15(Moisture Resistance, IS 302-1) |
- |
3000 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
3000 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
3000 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
3000 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
3000 |
|
- |
| 19.7(Abnormal Operation, IS 302-1) |
- |
3000 |
|
- |
| 19.8(Abnormal Operation, IS 302-1) |
- |
3000 |
|
- |
| 19.9(Abnormal Operation, IS 302-1) |
- |
3000 |
|
- |
| 19.1(Abnormal Operation, IS 302-1) |
- |
3000 |
|
- |
| 19.101(Abnormal Operation) |
- |
3000 |
|
- |
| 19.102(Abnormal Operation) |
- |
3000 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
3000 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
3000 |
|
- |
| 20.101(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.102(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.103(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.104(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.105(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.106(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.107(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.108(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.109(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.110(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.111(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.112(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.113(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.114(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.115(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 20.116(Stability & Mechanical Hazards) |
- |
3000 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
3000 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
3000 |
|
- |
| 22(Construction, IS 302-1) |
- |
3000 |
|
- |
| 22.101(Construction) |
- |
3000 |
|
- |
| 22.102(Construction) |
- |
3000 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 23.10(Internal Wiring, IS 302-1) |
- |
3000 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
3000 |
|
- |
| 27(Provision for Earthing, IS 302-1) |
- |
3000 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
3000 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
3000 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
3000 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
3000 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
3000 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
3000 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
3000 |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
3000 |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
3000 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
3000 |
|
- |
| 4(GENERAL REQUIREMENTS) |
- |
3000 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
3000 |
|
- |
| 27(Provision for Earthing) |
- |
3000 |
|
- |
| 29(Clearances, Creepage distances and Solid Insulation) |
- |
3000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
3000 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
3000 |
|
- |
| 32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
3000 |
|
- |
|
20 Jun, 2026 |
- Included w.e.f 08.12.2025
"24.1 (Components, IS 302-1)
24.2 (Components, IS 302-1)
24.5 (Components, IS 302-1)
24.6 (Components, IS 302-1)
EMI/EMC 19.11.4.1 to 19.11.4.7" |
| 3197 |
BIS, Central Laboratory (CL)
| None
| IS 8877 (2023) |
Acetoacetic methyl ester - Specification (Third Revision) |
- |
Rs. 4,060/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-3.1 (Description) |
- |
|
|
|
| Cl-3.2, Table-1 (i) (Assay, percent by mass, Min) |
- |
|
|
|
| Cl-3.2, Table-1 (ii) (Acidity (as CH3COOH), percent by mass, Max) |
- |
|
|
|
| Cl-3.2, Table-1 (iii) (Moisture content, percent by mass, Max) |
- |
|
|
|
|
- |
- - |
| 3198 |
Atmy Analytical Labs Private Limited (Unit-2), Greater Noida
| 8176106
| IS 1897 (2008) |
Copper strip for electrical purposes - Specification (Third Revision) |
- |
14900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| CLAUSE 4(SUPPLY OF MATERIAL) |
- |
500 |
|
- |
| CLAUSE 6(CHEMICAL COMPOSITION) |
- |
3500 |
|
- |
| CLAUSE 8(MECHANICAL PROPERTIES) |
- |
5500 |
|
- |
| CLAUSE 8.2(Bend Test) |
- |
1500 |
|
- |
| CLAUSE 9(ELECTRICAL RESISTIVITY TEST) |
- |
2000 |
|
- |
| CLAUSE 10(TEST FOR CONTROLLED PROOF RESISTANCE (OPTIONAL)) |
- |
2500 |
|
- |
| CLAUSE 11(DlMENSIONS AND TOLERANCES) |
- |
2500 |
|
- |
| CLAUSE 13(RETEST) |
- |
0 |
|
- |
| Cl. 8.3(Edgewise bending,) |
- |
1000 |
|
- |
| Cl. 8.3(Thickness) |
- |
0 |
|
- |
| Cl. 8.3(Tensile) |
- |
0 |
|
- |
| Cl. 8.3(Elongation) |
- |
0 |
|
- |
| Cl. 8.3(Hardness) |
- |
1500 |
|
- |
|
08 Feb, 2027 |
- Included w.e.f.29.09.2025 |
| 3199 |
RTRC LIMITED, GURUGRAM
| 9177406
| IS 2593 (1984) |
Flexible Cables for Miners' Cap-lamps |
Flexible Cables for Miners' Cap- Lamps — Specification |
37000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(CONDUCTOR) |
- |
1000 |
|
- |
| 3.1.1(Per sulphate test ) |
- |
2000 |
|
- |
| 3.1.2(Resistance test ) |
- |
500 |
|
- |
| 4.1(INSULATION) |
- |
500 |
|
- |
| 5.1(CENTRAL STRAIN CORD) |
- |
500 |
|
- |
| 6.1(SHEATH) |
- |
1000 |
|
- |
| 7.1(Construction : Conductor ) |
- |
500 |
|
- |
| 8.1(Thickness of Insulation - Average ) |
- |
500 |
|
- |
| 8.1(Thickness of Insulation - minimum) |
- |
500 |
|
- |
| 9.1(IDENTIFICATION OF CORES) |
- |
0 |
|
- |
| 10.1(LAYING UP) |
- |
0 |
|
- |
| 11.1(SHEATH : Application ) |
- |
0 |
|
- |
| 11.2(Thickness of Sheath -average ) |
- |
500 |
|
- |
| 12.2(Thickness of Sheath - Minimum) |
- |
500 |
|
- |
| 11.3(Coulor of sheath ) |
- |
1000 |
|
- |
| 12.1(OVERALL DIAMETER) |
- |
1000 |
|
- |
| 13.1 b)(Annealing test) |
- |
500 |
|
- |
| 13.1 e) 1)(Physical tests for insulation: Tensile strength ) |
- |
500 |
|
- |
| 13.1 e) 1)(Physical tests for insulation: elongation at break ) |
- |
500 |
|
- |
| 13.1 e) 1)(Physical tests for Sheath : Tensile strength ) |
- |
500 |
|
- |
| 13.1 e) 1)(Physical tests for Sheath: elongation at break ) |
- |
500 |
|
- |
| 13.1 e) 2)(Ageing in air oven ( for insulation ) : Tensile Strength ) |
- |
0 |
|
- |
| 13.1 e) 2)(Ageing in air oven ( for insulation ) : Tensile Strength variation ) |
- |
0 |
|
- |
| 13.1 e) 2)(Ageing in air oven ( for insulation ) : elongation variation at break) |
- |
500 |
|
- |
| 13.1 e) 2)(Ageing in air oven ( for insulation ) : elongation variation at break) |
- |
500 |
|
- |
| 13.1 e) 3)(Ageing in oxygen bomb ( for insulation ) : Tensile Strength variation ) |
- |
500 |
|
- |
| 13.1 e) 3)(Ageing in oxygen bomb ( for insulation ) : elongation variation at break) |
- |
500 |
|
- |
| 13.1 e) 3)(Ageing in air bomb ( for sheath ) : Tensile Strength variation ) |
- |
500 |
|
- |
| 13.1 e) 3)(Ageing in air bomb ( for sheath ) : elongation variation at break) |
- |
500 |
|
- |
| 13.1 e) 4)(Oil resistance test ( for sheath ) : Tensile strength variation ) |
- |
2500 |
|
- |
| 13.1 e) 4)(Oil resistance test ( for sheath ) : Elongation variation ) |
- |
2500 |
|
- |
| 14.1(Voltage test) |
- |
3500 |
|
- |
| 14.2(Flammability test) |
- |
3500 |
|
- |
| 14.3.1(Centre Strain Cord : Breaking Load ) |
- |
1000 |
|
- |
| 14.3.2(Centre Strain Cord : Determination of Copper and Manganese Content) |
- |
0 |
|
- |
| 14.4(Checking of overall diameter of cable) |
- |
500 |
|
- |
| 14.5(Resistance of sheath to fatty acids : Weigth Increase ) |
- |
2000 |
|
- |
| 14.5(Resistance of sheath to fatty acids : Diameter Increase ) |
- |
2000 |
|
- |
| 15.1(MANUFACTURER'S IDENTIFICATION) |
- |
500 |
|
- |
| 16.1(Packing ) |
- |
0 |
|
- |
| 16.2(Marking ) |
- |
0 |
|
- |
| 16.2.1(Standards Mark ) |
- |
0 |
|
- |
| 6.1(Resistance of Sheath to Fatty Acids - 14.5 - diameter increase) |
- |
0 |
|
- |
| 6.1(Resistance of Sheath to Fatty Acids - 14.5 - weight increase) |
- |
0 |
|
- |
| 5.1(Copper and Manganese Content - Cl 14.3.2) |
- |
1000 |
|
- |
| 3.1.1(mass of copper - Cl 7.1 of IS 8130 read with Method B of IS 10810 (Part 4)) |
- |
2500 |
|
- |
| 3.1(CONDUCTOR) |
- |
0 |
|
- |
| 3.1.1(Per sulphate test ) |
- |
0 |
|
- |
| 3.1.2(Resistance test ) |
- |
0 |
|
- |
| 4.1(INSULATION) |
- |
0 |
|
- |
| 5.1(CENTRAL STRAIN CORD) |
- |
0 |
|
- |
| 6.1(SHEATH) |
- |
0 |
|
- |
| 7.1(Construction : Conductor ) |
- |
0 |
|
- |
| 8.1(Thickness of Insulation - Average ) |
- |
0 |
|
- |
| 8.1(Thickness of Insulation - minimum) |
- |
0 |
|
- |
| 9.1(IDENTIFICATION OF CORES) |
- |
0 |
|
- |
| 10.1(LAYING UP) |
- |
0 |
|
- |
| 11.1(SHEATH : Application ) |
- |
0 |
|
- |
| 11.2(Thickness of Sheath -average ) |
- |
0 |
|
- |
| 12.2(Thickness of Sheath - Minimum) |
- |
0 |
|
- |
| 11.3(Coulor of sheath ) |
- |
0 |
|
- |
| 12.1(OVERALL DIAMETER) |
- |
0 |
|
- |
| 13.1 b)(Annealing test) |
- |
0 |
|
- |
| 13.1 e) 1)(Physical tests for insulation: Tensile strength ) |
- |
0 |
|
- |
| 13.1 e) 1)(Physical tests for insulation: elongation at break ) |
- |
0 |
|
- |
| 13.1 e) 1)(Physical tests for Sheath : Tensile strength ) |
- |
0 |
|
- |
| 13.1 e) 1)(Physical tests for Sheath: elongation at break ) |
- |
0 |
|
- |
| 13.1 e) 2)(Ageing in air oven ( for insulation ) : Tensile Strength ) |
- |
0 |
|
- |
| 13.1 e) 2)(Ageing in air oven ( for insulation ) : Tensile Strength variation ) |
- |
0 |
|
- |
| 13.1 e) 2)(Ageing in air oven ( for insulation ) : elongation variation at break) |
- |
0 |
|
- |
| 13.1 e) 2)(Ageing in air oven ( for insulation ) : elongation variation at break) |
- |
0 |
|
- |
| 13.1 e) 3)(Ageing in oxygen bomb ( for insulation ) : Tensile Strength variation ) |
- |
0 |
|
- |
| 13.1 e) 3)(Ageing in oxygen bomb ( for insulation ) : elongation variation at break) |
- |
0 |
|
- |
| 13.1 e) 3)(Ageing in air bomb ( for sheath ) : Tensile Strength variation ) |
- |
0 |
|
- |
| 13.1 e) 3)(Ageing in air bomb ( for sheath ) : elongation variation at break) |
- |
0 |
|
- |
| 13.1 e) 4)(Oil resistance test ( for sheath ) : Tensile strength variation ) |
- |
0 |
|
- |
| 13.1 e) 4)(Oil resistance test ( for sheath ) : Elongation variation ) |
- |
0 |
|
- |
| 14.1(Voltage test) |
- |
0 |
|
- |
| 14.2(Flammability test) |
- |
0 |
|
- |
| 14.3.1(Centre Strain Cord : Breaking Load ) |
- |
0 |
|
- |
| 14.3.2(Centre Strain Cord : Determination of Copper and Manganese Content) |
- |
0 |
|
- |
| 14.4(Checking of overall diameter of cable) |
- |
0 |
|
- |
| 14.5(Resistance of sheath to fatty acids : Weigth Increase ) |
- |
0 |
|
- |
| 14.5(Resistance of sheath to fatty acids : Diameter Increase ) |
- |
0 |
|
- |
| 15.1(MANUFACTURER'S IDENTIFICATION) |
- |
0 |
|
- |
| 16.1(Packing ) |
- |
0 |
|
- |
| 16.2(Marking ) |
- |
0 |
|
- |
| 16.2.1(Standards Mark ) |
- |
0 |
|
- |
|
03 Apr, 2027 |
- Included w.e.f 11.09.2025 |
| 3200 |
Electrical Research and Development Association, gujurat
| 7101125
| IS 16221 : Part 1 (2016) |
Safety of Power Converters for use in Photovoltaic Power Systems Part 1 General Requirements |
Upto 250 kVA |
979000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 15(Software and firmware performing safety functions) |
- |
10000 |
|
0.1 to 20 kW: 10000
20.1 to 50 kW: 10000
50.1 to 125 kW: 10000
125.1 to 250 kW: 10000 |
| 14(Components) |
- |
60000 |
|
0.1 to 20 kW: 15000
20.1 to 50 kW: 25000
50.1 to 125 kW: 40000
125.1 to 250 kW: 60000 |
| 13(Physical requirements) |
- |
60000 |
|
0.1 to 20 kW: 25000
20.1 to 50 kW: 30000
50.1 to 125 kW: 50000
125.1 to 250 kW: 60000 |
| 12(Chemical hazards) |
- |
27000 |
|
0.1 to 20 kW: 15000
20.1 to 50 kW: 15000
50.1 to 125 kW: 20000
125.1 to 250 kW: 27000 |
| 11(Protection against liquid hazards) |
- |
27000 |
|
0.1 to 20 kW: 15000
20.1 to 50 kW: 15000
50.1 to 125 kW: 20000
125.1 to 250 kW: 27000 |
| 10(Protection against Sonic Pressure hazards) |
- |
60000 |
|
0.1 to 20 kW: 15000
20.1 to 50 kW: 20000
50.1 to 125 kW: 40000
125.1 to 250 kW: 60000 |
| 9(Protection Against Fire Hazards) |
- |
140000 |
|
0.1 to 20 kW: 20000
20.1 to 50 kW: 30000
50.1 to 125 kW: 70000
125.1 to 250 kW: 140000 |
| 8(Protection Against mechanical Hazards) |
- |
140000 |
|
0.1 to 20 kW: 20000
20.1 to 50 kW: 30000
50.1 to 125 kW: 70000
125.1 to 250 kW: 140000 |
| 7(Protection against electric shock and energy hazards) |
- |
140000 |
|
0.1 to 20 kW: 25000
20.1 to 50 kW: 30000
50.1 to 125 kW: 70000
125.1 to 250 kW: 140000 |
| 6(Environmental Requirements and conditions) |
- |
150000 |
|
0.1 to 20 kW: 25000
20.1 to 50 kW: 40000
50.1 to 125 kW: 75000
125.1 to 250 kW: 150000 |
| 5(Marking and documentation) |
- |
5000 |
|
0.1 to 20 kW: 5000
20.1 to 50 kW: 5000
50.1 to 125 kW: 5000
125.1 to 250 kW: 5000 |
| 4(General testing requirements) |
- |
160000 |
|
0.1 to 20 kW: 30000
20.1 to 50 kW: 50000
50.1 to 125 kW: 85000
125.1 to 250 kW: 160000 |
| 14(Components) |
- |
60000 |
|
- |
| 6.4(UV exposure) |
- |
150000 |
|
- |
| 13.6.4(UV Resistance) |
- |
60000 |
|
- |
| Annex J(Ultraviolet light conditioning test) |
- |
0 |
|
- |
| 9.1.4.3(Hot flaming oil test) |
- |
0 |
|
- |
| 4.2(Thermal testing) |
- |
160000 |
|
- |
| 4.4(Testing in single fault condition) |
- |
160000 |
|
- |
| 4.5(Humidity preconditioning) |
- |
160000 |
|
- |
| 4.6(Backfeed voltage protection) |
- |
160000 |
|
- |
| 4.7(Electrical rating tests) |
- |
160000 |
|
- |
| 4.8(Additional tests for grid interactive inverters) |
- |
160000 |
|
- |
| Annex A(Measurement of clearances and creepage distances) |
- |
0 |
|
- |
| Annex B(Programmable equipment) |
- |
0 |
|
- |
| Annex C(Symbols to be used in equipment markings) |
- |
0 |
|
- |
| Annex D(Test probes for determining access) |
- |
0 |
|
- |
| Annex E(RCDs) |
- |
0 |
|
- |
| Annex F(Altitude correction for clearances) |
- |
0 |
|
- |
| Annex G(Clearance and creepage distance determination for frequencies greater than 30 kHz) |
- |
0 |
|
- |
| Annex H("Measuring instrument for touch current measurements
") |
- |
0 |
|
- |
| Annex I("Examples of protection, insulation, and overvoltage category requirements for PCE
") |
- |
0 |
|
- |
| 4.3, 4.3.2, 4.3.2.2, 4.3.2.3(Thermal Tests (Maximum temperatures, Touch temperature, temperature limits for mount surfaces)) |
- |
160000 |
|
- |
| 4.4.3.1(Protection against shock hazard) |
- |
160000 |
|
- |
| 4.4.3.2(Protection against spread of fire) |
- |
160000 |
|
- |
| 4.4.3.4(Protection Against parts expulsion hazards) |
- |
160000 |
|
- |
| 4.4.4.1(Component fault tests) |
- |
160000 |
|
- |
| 4.4.4.2(Equipment’s or parts for short-term or intermittent operation) |
- |
160000 |
|
- |
| 4.4.4.3(Motors(Lock rotor)) |
- |
160000 |
|
- |
| 4.4.4.4(Transformer short circuit tests) |
- |
160000 |
|
- |
| 4.4.4.5(Output short circuit) |
- |
160000 |
|
- |
| 4.4.4.6(Backfeed current test for equipment with more than one source of supply) |
- |
160000 |
|
- |
| 4.4.4.7(Output overload) |
- |
160000 |
|
- |
| 4.4.4.8(Cooling system failure) |
- |
160000 |
|
- |
| 4.4.4.9(Heating devices) |
- |
160000 |
|
- |
| 4.4.4.10(Safety interlock systems) |
- |
160000 |
|
- |
| 4.4.4.11(Reverse d.c. connections) |
- |
160000 |
|
- |
| 4.4.4.12(Voltage selector mismatch) |
- |
160000 |
|
- |
| 4.4.4.13(Mis-wiring with incorrect phase sequence or polarity) |
- |
160000 |
|
- |
| 4.4.4.14(Printed wiring board short-circuit test) |
- |
160000 |
|
- |
| 4.6.1(Backfeed tests under normal conditions) |
- |
160000 |
|
- |
| 4.6.2(Backfeed tests under single-fault conditions) |
- |
160000 |
|
- |
| 5.1.2(Durability of markings) |
- |
5000 |
|
- |
| 5.2.1(Visibility and legibility requirements for warning markings) |
- |
5000 |
|
- |
| 6.3(Ingress protection) |
- |
150000 |
|
- |
| 7.3.2.3(Short-term limits of accessible voltages under fault conditions) |
- |
140000 |
|
- |
| 7.3.2.6(Working voltage and DVC) |
- |
140000 |
|
- |
| 7.3.4,7.3.4.2(protection against direct contact) |
- |
140000 |
|
- |
| 7.3.4.3(Protection by means of insulation of live parts) |
- |
140000 |
|
- |
| 7.3.5,7.3.5.2(Protection in case of direct contact) |
- |
140000 |
|
- |
| 7.3.5.3.1(Limitation of current through protective impedance) |
- |
140000 |
|
- |
| 7.3.5.3.2(Limitation of discharging energy through protective impedance) |
- |
140000 |
|
- |
| 7.3.5.4(Protection by means of limited voltages) |
- |
140000 |
|
- |
| 7.3.6.1,7.3.6.2(Protection against indirect contact(Creapage & clearance)) |
- |
140000 |
|
- |
| 7.3.6.3(Protective class I - Protective bonding and earthing) |
- |
140000 |
|
- |
| 7.3.6.3.3(Rating of protective bonding) |
- |
140000 |
|
- |
| 7.3.7.8.4.2(Use of coating materials (on PWBs)) |
- |
140000 |
|
- |
| 7.3.7.4(Clearance distances) |
- |
140000 |
|
- |
| 7.3.7.5(Creepage distances) |
- |
140000 |
|
- |
| 7.3.8(Residual current detection (RCD) or Monitoring (RCM) device compatibilty (DC components on AC side)) |
- |
140000 |
|
- |
| 7.3.9(Protection against shock hazard due to stored energy) |
- |
140000 |
|
- |
| 7.4(Protection against energy hazards) |
- |
140000 |
|
- |
| 7.5.1(Impulse voltage test (type test)) |
- |
140000 |
|
- |
| 7.5.2(Voltage test (dielectric strength test)) |
- |
140000 |
|
- |
| 7.5.2.3(Humidity preconditioning) |
- |
140000 |
|
- |
| 7.5.3(Partial discharge test (type test or sample test)) |
- |
140000 |
|
- |
| 7.5.4(Touch current measurement) |
- |
140000 |
|
- |
| 7.3.7.5(Creepage distances) |
- |
140000 |
|
- |
| 7.3.8(Residual current detection (RCD) or Monitoring (RCM) device compatibilty (DC components on AC side)) |
- |
140000 |
|
- |
| 7.3.9(Protection against shock hazard due to stored energy) |
- |
140000 |
|
- |
| 7.4(Protection against energy hazards) |
- |
140000 |
|
- |
| 7.5.1(Impulse voltage test (type test)) |
- |
140000 |
|
- |
| 7.5.2(Voltage test (dielectric strength test)) |
- |
140000 |
|
- |
| 7.5.2.3(Humidity preconditioning) |
- |
140000 |
|
- |
| 7.5.3(Partial discharge test (type test or sample test)) |
- |
140000 |
|
- |
| 7.5.4(Touch current measurement) |
- |
140000 |
|
- |
| 8.2(Moving parts) |
- |
140000 |
|
- |
| 8.3(Stability) |
- |
140000 |
|
- |
| 8.4(Provisions for lifting and carrying) |
- |
140000 |
|
- |
| 8.5(Wall mounting) |
- |
140000 |
|
- |
| 8.6(Expelled parts) |
- |
140000 |
|
- |
| 9.1.1(Reducing the risk of ignition and spread of flame) |
- |
140000 |
|
- |
| 9.1.2(Conditions for a fire enclosure) |
- |
140000 |
|
- |
| 9.1.3(Material requirements for protection against fire hazard) |
- |
140000 |
|
- |
| 9.1.4(Openings in fire enclosures) |
- |
140000 |
|
- |
| 9.1.4.6(Additional requirements for openings in transportable equipment) |
- |
140000 |
|
- |
| 9.2.2(Limited power source tests) |
- |
140000 |
|
- |
| 9.3(Short-circuit and overcurrent protection) |
- |
140000 |
|
- |
| 10.2(Sonic pressure and sound level) |
- |
60000 |
|
- |
| 11.1(Liquid containment, pressure and leakage) |
- |
27000 |
|
- |
| 11.2(Fluid pressure and leakage) |
- |
27000 |
|
- |
| 13.1(Handles and manual controls) |
- |
60000 |
|
- |
| 13.1.1(Adjustable controls) |
- |
60000 |
|
- |
| 13.2(Securing of parts) |
- |
60000 |
|
- |
| 13.3(Provisions for external connections) |
- |
60000 |
|
- |
| 13.4(Internal wiring and connections) |
- |
60000 |
|
- |
| 13.5(Openings in enclosures) |
- |
60000 |
|
- |
| 13.3.2.5(Cord anchorages and strain relief) |
- |
60000 |
|
- |
| 13.3.5(Wire bending space for wires 10mm2 and greater) |
- |
60000 |
|
- |
| 13.5(Openings in enclosures) |
- |
60000 |
|
- |
| 13.6.2.1(Stress relief test) |
- |
60000 |
|
- |
| 13.7(Mechanical resistance to deflection, impact, or drop) |
- |
60000 |
|
- |
| 13.8(Thickness requirements for metal enclosures) |
- |
60000 |
|
- |
| 14.2(Motor over-temperature protection) |
- |
60000 |
|
- |
| 14.3(Over-temperature protection devices) |
- |
60000 |
|
- |
| 14.6(Printed circuit boards) |
- |
60000 |
|
- |
| 14.7(Circuits or components used as transient overvoltage limiting devices) |
- |
60000 |
|
- |
| 11.3(Oil and grease) |
- |
27000 |
|
- |
| Cl.13.6.1.1(Thermal index or capability) |
- |
60000 |
|
- |
| Cl.13.6.3.1(Resistance to arcing) |
- |
60000 |
|
- |
| Cl.14.8(Batteries) |
- |
60000 |
|
- |
|
30 Nov, 2028 |
- Included w.e.f. 23.01.2026 |
| 3201 |
Atmy Analytical Labs Private Limited (Unit-2), Greater Noida
| 8176106
| IS 210 (2009) |
Grey iron castings - Specification (First Revision) |
- |
6500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Chemical Composition(chemical
composition shall be as agreed to between the
purchaser and the manufacturer.)) |
- |
2500 |
|
- |
| 7.1(WORKMANSHIP AND FINISH) |
- |
1000 |
|
- |
| 10.1(FREEDOM FROM DEFECTS) |
- |
1000 |
|
- |
| 10.2(FREEDOM FROM DEFECTS) |
- |
0 |
|
- |
| 13(SIZE OF TEST BARS-Diameter) |
- |
500 |
|
- |
| 13(SIZE OF TEST BARS-Length) |
- |
500 |
|
- |
| 15, Table 3(TENSIL.E TEST- IS 1608 Part1 ) |
- |
2500 |
|
- |
| 16, Table 3(Hardness Test) |
- |
1000 |
|
- |
| 17,Annex B(TRANSVERSE TEST) |
- |
1000 |
|
- |
| 18(HYDROSTATIC TEST) |
- |
3500 |
|
- |
| 6(Chemical Composition(chemical
composition shall be as agreed to between the
purchaser and the manufacturer.)) |
- |
0 |
|
- |
| 7.1(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
| 10.1(FREEDOM FROM DEFECTS) |
- |
0 |
|
- |
| 10.2(FREEDOM FROM DEFECTS) |
- |
0 |
|
- |
| 13(SIZE OF TEST BARS-Diameter) |
- |
0 |
|
- |
| 13(SIZE OF TEST BARS-Length) |
- |
0 |
|
- |
| 15, Table 3(TENSIL.E TEST- IS 1608 Part1 ) |
- |
0 |
|
- |
| 16, Table 3(Hardness Test) |
- |
0 |
|
- |
| 17,Annex B(TRANSVERSE TEST) |
- |
0 |
|
- |
| 18(HYDROSTATIC TEST) |
- |
0 |
|
- |
| 9(IS 7754) |
- |
1500 |
|
- |
| 9(IS 7754) |
- |
0 |
|
- |
| 9(Microstructure) |
- |
0 |
|
- |
| 21(Marking) |
- |
500 |
|
- |
| 9(Microstructure) |
- |
0 |
|
- |
| 7.2(Casting dimensions) |
- |
1500 |
|
- |
| Cl-6(Phosprorus (P) - IS 12308 ( P-5)) |
- |
0 |
|
- |
|
08 Feb, 2027 |
- Included w.e.f. 09.10.2025 |
| 3202 |
BIS, Central Laboratory (CL)
| None
| IS 12640 : Part 1 (2024) |
Residual current operated circuitBreakers without integral overcurrent protection for household and similar uses Rccbs: Part 1 general rules (Third Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 (Marking) |
- |
|
|
|
| 8.1.1 (General) |
- |
|
|
|
| 8.1.2 (Mechanism) |
- |
|
|
|
| 8.1.3 (Clearance and creepage distance (External parts only)) |
- |
|
|
|
| 8.1.3 (Clearance and creepage distance (Internal parts only)) |
- |
|
|
|
| 9.15 (Trip free mechanism) |
- |
|
|
|
| 9.4 (Reliability of screws, current-carrying parts and connections) |
- |
|
|
|
| 9.5 (Reliability of terminals for external conductors) |
- |
|
|
|
| 9.6 (Protection againts electrci shock) |
- |
|
|
|
| 9.13 (Resistance to heat) |
- |
|
|
|
| 9.7.1 (Resistance to humidity) |
- |
|
|
|
| 9.7.2 (Insulation resistance of the main circuit) |
- |
|
|
|
| 9.7.3 (Dielectric strength of the main circuit) |
- |
|
|
|
| 9.8 (Temperature-rise) |
- |
|
|
|
| 9.14 (Resistance to abnormal heat and to fire) |
- |
|
|
|
| 9.25 (Resistance to rusting) |
- |
|
|
|
|
- |
- Testing facility not available for 1. Trip free mechanism, 2. Resistance of insulation against impulse voltage, 3. Reliability at 40 °C 4. Aging of electric components, 5. Mechanical and electrical endurance 6. Test sequence D 7. Test sequence E 8. Test sequence F, 9. Test sequence G, 10. Verification of the suitability of RCCB for use in IT system |
| 3203 |
EMC Testing and Compliance LLP, Gurugram
| 8141526
| IS 17358 : Part 1 (2020) |
Agro textiles “ Fencing nets for agriculture and horticulture purposes “ Specification Part 1 Fencing nets made from extruded polymer mesh |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4, table 1,2,3(MATERIALS) |
- |
2500 |
|
- |
| 5,/ 5.1( MANUFACTURE (a)Hexagonal shape (see Fig. 1);(b) Diamond shape (see Fig. 2); and
c) Square shape (see Fig. 3)) |
- |
500 |
|
- |
| 5.2(Colour) |
- |
1000 |
|
- |
| 6.0(TYPES ,(a)Light duty,
b) Medium duty, and
c) Heavy duty.) |
- |
0 |
|
- |
| 7.0( REQUIREMENTS) |
- |
0 |
|
- |
| 4, table 1,2,3(MATERIALS) |
- |
2500 |
|
- |
| 5,/ 5.1( MANUFACTURE (a)Hexagonal shape (see Fig. 1);(b) Diamond shape (see Fig. 2); and
c) Square shape (see Fig. 3)) |
- |
500 |
|
- |
| 5.2(Colour) |
- |
1000 |
|
- |
| 6.0(TYPES ,(a)Light duty,
b) Medium duty, and
c) Heavy duty.) |
- |
0 |
|
- |
| 7.0( REQUIREMENTS) |
- |
0 |
|
- |
| Cl. 4(Raw Material: Overall Migration) |
- |
1000 |
|
- |
| Cl. 5, 5.1(Shape of Net) |
- |
0 |
|
- |
| 5.2(Colour) |
- |
1000 |
|
- |
| 6(Types) |
- |
0 |
|
- |
| Cl. 4 & 7, Table-1(Light Duty Fencing Net (Hexagonal Shape) :) |
- |
2000 |
|
- |
| (i)(Mass) |
- |
2000 |
|
- |
| (ii)(Mesh Size, Traverse Direction) |
- |
2000 |
|
- |
| (iii)(Mesh Size, Cross Direction) |
- |
2000 |
|
- |
| (iv)(Thickness at joint) |
- |
2000 |
|
- |
| (v)(Filament Thickness) |
- |
2000 |
|
- |
| (vi)(Dimensions:) |
- |
2000 |
|
- |
| (vi)(Length) |
- |
2000 |
|
- |
| (vi)(Width) |
- |
2000 |
|
- |
| (vii) a(Tensile Strength before UV exposure, Machine Direction) |
- |
2000 |
|
- |
| (vii) b(Tensile Strength before UV exposure, Traverse Direction) |
- |
2000 |
|
- |
| (viii) a(Elongation before UV exposure, Machine Direction) |
- |
2000 |
|
- |
| (viii) b(Elongation before UV exposure, Traverse Direction) |
- |
2000 |
|
- |
| (ix) a(Tensile Strength after UV exposure, Machine Direction) |
- |
2000 |
|
- |
| (ix) b(Tensile Strength after UV exposure, Traverse Direction) |
- |
2000 |
|
- |
|
19 Jul, 2027 |
- Included w.e.f.11.09.2025 |
| 3204 |
Atmy Analytical Labs Private Limited (Unit-2), Greater Noida
| 8176106
| IS 6419 (1996) |
Welding rods and bare electrodes for gas shielded arc welding of structural steel - Specification (First Revision) |
- |
29850 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Diameter) |
- |
1000 |
|
- |
| 6(Reels for Wire) |
- |
500 |
|
- |
| 7(Reeling Condition) |
- |
500 |
|
- |
| 8(Dimension of Spools, Rims & Coils) |
- |
1500 |
|
- |
| 9(Lengthof Rods) |
- |
1000 |
|
- |
| 10.1(Finish) |
- |
1500 |
|
- |
| 10.1(Copper Content of Coated Wire or Rod) |
- |
1000 |
|
- |
| 10.2.1 Table 5(Tensile Strength-IS 1608(P-1)) |
- |
3500 |
|
- |
| 10.2.2 Table 6(Cast- As per Cl.10.2.2 ) |
- |
1500 |
|
- |
| 10.2.3 Table 6(Helix- As per Cl.10.2.3 ) |
- |
1500 |
|
- |
| 14.1 Table 7(Carbon-Relevant parts of IS 228) |
- |
1000 |
|
- |
| 14.1 Table 7(Manganese-Relevant parts of IS 228) |
- |
1000 |
|
- |
| 14.1 Table 7(Silicon-Relevant parts of IS 228) |
- |
1000 |
|
- |
| 14.1 Table 7(Phosphorous-Relevant parts of IS 228) |
- |
1000 |
|
- |
| 14.1 Table 7(Sulphur-Relevant parts of IS 228) |
- |
1000 |
|
- |
| 14.1 Table 7(Nickel-Relevant parts of IS 228) |
- |
1000 |
|
- |
| 14.1 Table 7(Chromium-Relevant parts of IS 228) |
- |
1000 |
|
- |
| 14.1 Table 7(Molybdenum-Relevant parts of IS 228) |
- |
1000 |
|
- |
| 14.1 Table 7(Vanadium-Relevant parts of IS 228) |
- |
1000 |
|
- |
| 14.1 Table 7(Copper-Relevant parts of IS 228) |
- |
1000 |
|
- |
| 14.1 Table 7(Titanium-Relevant parts of IS 228) |
- |
1000 |
|
- |
| 14.1 Table 7(Zirconium-Relevant parts of IS 228) |
- |
1000 |
|
- |
| 14.1 Table 7(Aluminium-Relevant parts of IS 228) |
- |
1000 |
|
- |
| 14.1 Table 7(Mo+Ni+Cr-Relevant parts of IS 228) |
- |
1000 |
|
- |
| 10.2.1(Welding rods and bare electrodes for gas shielded arc welding of structural steel) |
- |
3500 |
|
- |
| 14.2(Soundness test) |
- |
6500 |
|
- |
| 14.3.2(UTS) |
- |
1500 |
|
- |
| 14.3.2(Yield Stress) |
- |
1500 |
|
- |
| 14.3.2(% of Elongation) |
- |
1500 |
|
- |
| 14.3.3(Impact Test) |
- |
3500 |
|
- |
|
08 Feb, 2027 |
- included w.e.f 09-12-2025. |
| 3205 |
Atmy Analytical Labs Private Limited (Unit-2), Greater Noida
| 8176106
| IS 1285 (2023) |
WROUGHT ALUMINIUM AND ALUMINIUM ALLOYS EXTRUDED ROUND TUBE AND HOLLOW SECTIONS FOR GENERAL ENGINEERINGPURPOSES SPECIFICATION |
- |
8000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.9.1(Aluminium- IS 504 and its parts or any other intrumental/chemical methods) |
- |
1000 |
|
- |
| Cl.9.1(Copper- IS 504 and its parts or any other intrumental/chemical methods) |
- |
1000 |
|
- |
| Cl.9.1(Magnesium- IS 504 and its parts or any other intrumental/chemical methods) |
- |
1000 |
|
- |
| Cl.9.1(Silicon- IS 504 and its parts or any other intrumental/chemical methods) |
- |
1000 |
|
- |
| Cl.9.1(Iron- IS 504 and its parts or any other intrumental/chemical methods) |
- |
1000 |
|
- |
| Cl.9.1(Manganese- IS 504 and its parts or any other intrumental/chemical methods) |
- |
1000 |
|
- |
| Cl.9.1(Zinc- IS 504 and its parts or any other intrumental/chemical methods) |
- |
1000 |
|
- |
| Cl.9.1(Titanium and/ or other grain refining elements- IS 504 and its parts or any other intrumental/chemical methods) |
- |
1000 |
|
- |
| Cl.9.1(Chromium- IS 504 and its parts or any other intrumental/chemical methods) |
- |
1000 |
|
- |
| Cl.9.1(Remarks (Ti+V) - IS 504 and its parts or any other intrumental/chemical methods) |
- |
1000 |
|
- |
| Cl.9.1(Remarks (Cr+Mn) - IS 504 and its parts or any other intrumental/chemical methods) |
- |
1000 |
|
- |
| Cl.9.1(Remarks (Total Impurities)- IS 504 and its parts or any other intrumental/chemical methods) |
- |
1000 |
|
- |
| 6(FREEDOM FROM DEFECTS) |
- |
1000 |
|
- |
| 8(DIMENSIONS AND TOLERANCES) |
- |
1000 |
|
- |
| 10(MECHANICAL PROPERTIES) |
- |
3500 |
|
- |
| Cl. 9(Aluminium) |
- |
0 |
|
- |
| Cl. 9(Copper) |
- |
0 |
|
- |
| Cl. 9(Magnesium) |
- |
0 |
|
- |
| Cl. 9(Silicon) |
- |
0 |
|
- |
| Cl. 9(Iron) |
- |
0 |
|
- |
| Cl. 9(Manganese) |
- |
0 |
|
- |
| Cl. 9(Zinc) |
- |
0 |
|
- |
| Cl. 9(Titanium and/or other grain refining elements) |
- |
0 |
|
- |
| Cl. 9(Chromium) |
- |
0 |
|
- |
| Cl. 9(Ti+V) |
- |
0 |
|
- |
| Cl. 9(Cr+Mn) |
- |
0 |
|
- |
| Clause-10(Tensile strength) |
- |
0 |
|
- |
|
08 Feb, 2027 |
- included w.e.f 09-12-2025. |
| 3206 |
ALPHA TEST HOUSE PVT LTD, BAHADURGARH
| 8185306
| IS 16653 (2017) |
Geosynthetics – Needle punched nonwoven geobags for coastal and waterways protection – Specification |
All |
85000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 4.1.1 Table 1 A (iii)(Seam strength, percentage of actual fabric strength) |
- |
4000 |
|
- |
| Cl 4.1.1 Table 1 A (vi)(CBR Puncture resistance (N)) |
- |
4000 |
|
- |
| Cl 4.1.1 Table 1 A (i) (a)(Wide with tensile strength , Machine direction) |
- |
4000 |
|
- |
| Cl 4.1.1 Table 1 A (ii) (a)(Elongation, Machine Direction) |
- |
4000 |
|
- |
| Cl 4.1.1 Table 1 A (iv)(Abrasion Resistance) |
- |
4000 |
|
- |
| Cl 4.1.1 Table 1 A (v) (a)(Trapezoidal tear strength, Machine Direction) |
- |
4000 |
|
- |
| Cl 4.1.1 Table 1 B (i)(Permittivity) |
- |
4000 |
|
- |
| Cl 4.1.1 Table 1 B (ii)(Water permittivity) |
- |
3000 |
|
- |
| Cl 4.1.1 Table 1 B (iii)(Apparent opening size) |
- |
3000 |
|
- |
| Cl 4.1.1 Table 1 C (i)(Thickness at 2kpa) |
- |
3000 |
|
- |
| Cl 4.1.1 Table 1 C (ii)(Polymer types) |
- |
3000 |
|
- |
| Cl 4.1.1 Table 1 C (iii)(Mass) |
- |
3000 |
|
- |
| Cl 4.1.1 Table 1 C (iv) (a)(Length of geobag, Small size) |
- |
3000 |
|
- |
| Cl 4.1.1 Table 1 C (v) (a)(Width of geobag, small size) |
- |
3000 |
|
- |
| Cl 4.1.1 Table 1 C (vi) (a)(Mass of sand filled geobag, small size) |
- |
3000 |
|
- |
| Cl 4.1.1 Table 1 C (vii)(Durability) |
- |
3000 |
|
- |
| Cl 4.1.1 Table 1 C (vii)(UV resistance after 500h) |
- |
3000 |
|
- |
| Cl 4.1.1 Table 1 A (i) (b)(Wide with tensile strength , Cross Machine direction) |
- |
3000 |
|
- |
| Cl 4.1.1 Table 1 A (ii) (b)(Elongation, Cross Machine Direction) |
- |
3000 |
|
- |
| Cl 4.1.1 Table 1 A (v) (b)(Trapezoidal tear strength, Cross Machine Direction) |
- |
3000 |
|
- |
| Cl 4.1.1 Table 1 C (iv) (b)(Length of geobag, large size) |
- |
3000 |
|
- |
| Cl 4.1.1 Table 1 C (v) (b)(Width of geobag, large size) |
- |
3000 |
|
- |
| Cl 4.1.1 Table 1 C (vi) (b)(Mass of sand filled geobag, large size) |
- |
3000 |
|
- |
| Cl 5(Marking) |
- |
3000 |
|
- |
| Cl 4.1.3(The isophthalic acid content of the virgin polyester fiber) |
- |
3000 |
|
- |
| Cl 4.3(Prefabrication of Geobags) |
- |
3000 |
|
- |
|
08 May, 2028 |
- Included w.e.f.12.09.2025 |
| 3207 |
Testtex India Laboratories Pvt. Ltd., Mumbai
| 7126506
| IS 17514 (2025) |
Reusable Sanitary Pad/Sanitary Napkin/Period Panties - Specification (First Revision) |
All |
17000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-3.1(Material- cover or the top sheet) |
- |
500 |
|
Complete Test Charges - Rs 17,000 + GST [Including Cl.9.5-Phthalates];All Prices are Except Cl.9.4 - Biocompatibility Evaluation-Cytotoxicity, Irritation and Skin Sensitization & Cl.10.0 - Anti Bacterial Activity Value (Optional Tests); |
| Cl-3.2(Material- absorbent core;) |
- |
500 |
|
Cl.10.0 - Anti Bacterial Activity Value - Rs 4000 + GST (10% Discount to BIS for Complete Testing) |
| Cl-3.3(Material- bottom layer.) |
- |
200 |
|
- |
| Cl-4(MANUFACTURE, WORKMANSHIP AND FINISH) |
- |
400 |
|
- |
| Cl-5(FASTENING MECHANISM) |
- |
200 |
|
- |
| Cl-6, Table-1(Length (mm) (Absorbent Core Only)) |
- |
250 |
|
- |
| Cl-6, Table-1(Width (mm) (Absorbent Core Only)) |
- |
250 |
|
- |
| Cl-7(WASHING, DRYING AND HANDLING INSTRUCTION) |
- |
200 |
|
- |
| Cl-8, Table-2 (i) (a)("Colour fastness to rubbing: Dry
") |
- |
150 |
|
- |
| Cl-8, Table-2 (i) (b)(Colour fastness to rubbing: Wet) |
- |
150 |
|
- |
| Cl-8, Table-2 (ii) (a)("Colour fastness to perspiration (acidic and alkaline): Colour change
") |
- |
200 |
|
- |
| Cl-8, Table-2 (ii) (b)(Colour fastness to perspiration (acidic and alkaline): Staining) |
- |
200 |
|
- |
| Cl-8, Table-2 (iii) (a)(Colour fastness to washing: Colour change) |
- |
200 |
|
- |
| Cl-8, Table-2 (iii) (b)(Colour fastness to washing: Staining) |
- |
200 |
|
- |
| Cl-8, Table-2 (iv)("Dimensional stability to washing, percentage, Max
Length and width") |
- |
400 |
|
- |
| Cl-9.1(pH Value) |
- |
400 |
|
- |
| Cl-9.2(Ability to Withstand Pressure after Absorption) |
- |
600 |
|
- |
| Cl-9.3(Hygiene Testing Requirement) |
- |
0 |
|
charges for 9.3.1: 5000, 9.3.2: 2500 |
| Cl-9.3.1(Bacterial and Fungal Bioburden) |
- |
5000 |
|
- |
| Cl-9.3.2(Test for Common Skin Pathogen — Staphylococcus Aureus) |
- |
2500 |
|
- |
| Cl-10(Anti-bacterial activity value) |
- |
0 |
|
(Clause 10: Anti Bacterial Activity Value- Testing Charges Rs: 4000/)- Optional Test |
| Cl-9.5(Phthalate Test) |
- |
4000 |
|
- |
| Cl-12(Marking) |
- |
500 |
|
Combined Charges for Clause 12 Marking and Clause 13 Packing 500 |
| Cl-3.1(Material- cover or the top sheet) |
- |
0 |
|
Repeated |
| Cl-3.2(Material- absorbent core;) |
- |
0 |
|
Repeated |
| Cl-3.3(Material- bottom layer.) |
- |
0 |
|
Repeated |
| Cl-4(MANUFACTURE, WORKMANSHIP AND FINISH) |
- |
0 |
|
Repeated |
| Cl-5(FASTENING MECHANISM) |
- |
0 |
|
Repeated |
| Cl-6, Table-1(Length (mm) (Absorbent Core Only)) |
- |
0 |
|
Repeated |
| Cl-6, Table-1(Width (mm) (Absorbent Core Only)) |
- |
0 |
|
Repeated |
| Cl-7(WASHING, DRYING AND HANDLING INSTRUCTION) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (i) (a)("Colour fastness to rubbing: Dry
") |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (i) (b)(Colour fastness to rubbing: Wet) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (ii) (a)("Colour fastness to perspiration (acidic and alkaline): Colour change
") |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (ii) (b)(Colour fastness to perspiration (acidic and alkaline): Staining) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (iii) (a)(Colour fastness to washing: Colour change) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (iii) (b)(Colour fastness to washing: Staining) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (iv)("Dimensional stability to washing, percentage, Max
Length and width") |
- |
0 |
|
Repeated |
| Cl-9.1(pH Value) |
- |
0 |
|
Repeated |
| Cl-9.2(Ability to Withstand Pressure after Absorption) |
- |
0 |
|
Repeated |
| Cl-9.3(Hygiene Testing Requirement) |
- |
0 |
|
Repeated |
| Cl-9.3.1(Bacterial and Fungal Bioburden) |
- |
0 |
|
Repeated |
| Cl-9.3.2(Test for Common Skin Pathogen — Staphylococcus Aureus) |
- |
0 |
|
Repeated |
| Cl-10(Anti-bacterial activity value) |
- |
0 |
|
Repeated |
| Cl-9.5(Phthalate Test) |
- |
0 |
|
Repeated |
| Cl-12(Marking) |
- |
0 |
|
Repeated |
| Cl-3.1(Material- cover or the top sheet) |
- |
0 |
|
Repeated |
| Cl-3.2(Material- absorbent core;) |
- |
0 |
|
Repeated |
| Cl-3.3(Material- bottom layer.) |
- |
0 |
|
Repeated |
| Cl-4(MANUFACTURE, WORKMANSHIP AND FINISH) |
- |
0 |
|
Repeated |
| Cl-5(FASTENING MECHANISM) |
- |
0 |
|
Repeated |
| Cl-6, Table-1(Length (mm) (Absorbent Core Only)) |
- |
0 |
|
Repeated |
| Cl-6, Table-1(Width (mm) (Absorbent Core Only)) |
- |
0 |
|
Repeated |
| Cl-7(WASHING, DRYING AND HANDLING INSTRUCTION) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (i) (a)("Colour fastness to rubbing: Dry
") |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (i) (b)(Colour fastness to rubbing: Wet) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (ii) (a)("Colour fastness to perspiration (acidic and alkaline): Colour change
") |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (ii) (b)(Colour fastness to perspiration (acidic and alkaline): Staining) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (iii) (a)(Colour fastness to washing: Colour change) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (iii) (b)(Colour fastness to washing: Staining) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (iv)("Dimensional stability to washing, percentage, Max
Length and width") |
- |
0 |
|
Repeated |
| Cl-9.1(pH Value) |
- |
0 |
|
Repeated |
| Cl-9.2(Ability to Withstand Pressure after Absorption) |
- |
0 |
|
Repeated |
| Cl-9.3(Hygiene Testing Requirement) |
- |
0 |
|
Repeated |
| Cl-9.3.1(Bacterial and Fungal Bioburden) |
- |
0 |
|
Repeated |
| Cl-9.3.2(Test for Common Skin Pathogen — Staphylococcus Aureus) |
- |
0 |
|
Repeated |
| Cl-10(Anti-bacterial activity value) |
- |
0 |
|
Repeated |
| Cl-9.5(Phthalate Test) |
- |
0 |
|
Repeated |
| Cl-12(Marking) |
- |
0 |
|
Repeated |
| Cl-3.1(Material- cover or the top sheet) |
- |
0 |
|
- |
| Cl-3.2(Material- absorbent core;) |
- |
0 |
|
Repeated |
| Cl-3.3(Material- bottom layer.) |
- |
0 |
|
Repeated |
| Cl-4(MANUFACTURE, WORKMANSHIP AND FINISH) |
- |
0 |
|
Repeated |
| Cl-5(FASTENING MECHANISM) |
- |
0 |
|
Repeated |
| Cl-6, Table-1(Length (mm) (Absorbent Core Only)) |
- |
0 |
|
Repeated |
| Cl-6, Table-1(Width (mm) (Absorbent Core Only)) |
- |
0 |
|
Repeated |
| Cl-7(WASHING, DRYING AND HANDLING INSTRUCTION) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (i) (a)("Colour fastness to rubbing: Dry
") |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (i) (b)(Colour fastness to rubbing: Wet) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (ii) (a)("Colour fastness to perspiration (acidic and alkaline): Colour change
") |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (ii) (b)(Colour fastness to perspiration (acidic and alkaline): Staining) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (iii) (a)(Colour fastness to washing: Colour change) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (iii) (b)(Colour fastness to washing: Staining) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (iv)("Dimensional stability to washing, percentage, Max
Length and width") |
- |
0 |
|
Repeated |
| Cl-9.1(pH Value) |
- |
0 |
|
Repeated |
| Cl-9.2(Ability to Withstand Pressure after Absorption) |
- |
0 |
|
Repeated |
| Cl-9.3(Hygiene Testing Requirement) |
- |
0 |
|
Repeated |
| Cl-9.3.1(Bacterial and Fungal Bioburden) |
- |
0 |
|
Repeated |
| Cl-9.3.2(Test for Common Skin Pathogen — Staphylococcus Aureus) |
- |
0 |
|
Repeated |
| Cl-10(Anti-bacterial activity value) |
- |
0 |
|
Repeated |
| Cl-9.5(Phthalate Test) |
- |
0 |
|
Repeated |
| Cl-12(Marking) |
- |
0 |
|
Repeated |
| Cl-3.1(Material- cover or the top sheet) |
- |
0 |
|
Repeated |
| Cl-3.2(Material- absorbent core;) |
- |
0 |
|
Repeated |
| Cl-3.3(Material- bottom layer.) |
- |
0 |
|
Repeated |
| Cl-4(MANUFACTURE, WORKMANSHIP AND FINISH) |
- |
0 |
|
Repeated |
| Cl-5(FASTENING MECHANISM) |
- |
0 |
|
Repeated |
| Cl-6, Table-1(Length (mm) (Absorbent Core Only)) |
- |
0 |
|
Repeated |
| Cl-6, Table-1(Width (mm) (Absorbent Core Only)) |
- |
0 |
|
Repeated |
| Cl-7(WASHING, DRYING AND HANDLING INSTRUCTION) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (i) (a)("Colour fastness to rubbing: Dry
") |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (i) (b)(Colour fastness to rubbing: Wet) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (ii) (a)("Colour fastness to perspiration (acidic and alkaline): Colour change
") |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (ii) (b)(Colour fastness to perspiration (acidic and alkaline): Staining) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (iii) (a)(Colour fastness to washing: Colour change) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (iii) (b)(Colour fastness to washing: Staining) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (iv)("Dimensional stability to washing, percentage, Max
Length and width") |
- |
0 |
|
Repeated |
| Cl-9.1(pH Value) |
- |
0 |
|
Repeated |
| Cl-9.2(Ability to Withstand Pressure after Absorption) |
- |
0 |
|
Repeated |
| Cl-12(Marking) |
- |
0 |
|
Repeated |
| Cl-9.3(Hygiene Testing Requirement) |
- |
0 |
|
Repeated |
| Cl-9.3.1(Bacterial and Fungal Bioburden) |
- |
0 |
|
Repeated |
| Cl-9.3.2(Test for Common Skin Pathogen — Staphylococcus Aureus) |
- |
0 |
|
Repeated |
| Cl-10(Anti-bacterial activity value) |
- |
0 |
|
Repeated |
| Cl-9.5(Phthalate Test) |
- |
0 |
|
Repeated |
| Cl-3.1(Material- cover or the top sheet) |
- |
0 |
|
Repeated |
| Cl-3.2(Material- absorbent core;) |
- |
0 |
|
Repeated |
| Cl-3.3(Material- bottom layer.) |
- |
0 |
|
Repeated |
| Cl-4(MANUFACTURE, WORKMANSHIP AND FINISH) |
- |
0 |
|
Repeated |
| Cl-5(FASTENING MECHANISM) |
- |
0 |
|
Repeated |
| Cl-6, Table-1(Length (mm) (Absorbent Core Only)) |
- |
0 |
|
Repeated |
| Cl-6, Table-1(Width (mm) (Absorbent Core Only)) |
- |
0 |
|
Repeated |
| Cl-7(WASHING, DRYING AND HANDLING INSTRUCTION) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (i) (a)("Colour fastness to rubbing: Dry
") |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (i) (b)(Colour fastness to rubbing: Wet) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (ii) (a)("Colour fastness to perspiration (acidic and alkaline): Colour change
") |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (ii) (b)(Colour fastness to perspiration (acidic and alkaline): Staining) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (iii) (a)(Colour fastness to washing: Colour change) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (iii) (b)(Colour fastness to washing: Staining) |
- |
0 |
|
Repeated |
| Cl-8, Table-2 (iv)("Dimensional stability to washing, percentage, Max
Length and width") |
- |
0 |
|
Repeated |
| Cl-9.1(pH Value) |
- |
0 |
|
Repeated |
| Cl-9.2(Ability to Withstand Pressure after Absorption) |
- |
0 |
|
Repeated |
| Cl-12(Marking) |
- |
0 |
|
Repeated |
| Cl-9.3(Hygiene Testing Requirement) |
- |
0 |
|
Repeated |
| Cl-9.3.1(Bacterial and Fungal Bioburden) |
- |
0 |
|
Repeated |
| Cl-9.3.2(Test for Common Skin Pathogen — Staphylococcus Aureus) |
- |
0 |
|
Repeated |
| Cl-10(Anti-bacterial activity value) |
- |
0 |
|
Repeated |
| Cl-9.5(Phthalate Test) |
- |
0 |
|
Repeated |
|
- |
- Included w.e.f 16.12.2025
Exclusion: Cl-9.3.3 (Good Manufacturing Practice Guideline for Hygiene Requirement), Cl-9.4 (Biocompatibility Evaluation — Cytotoxicity, Irritation and Skin Sensitization) |
| 3208 |
Standard Testing and Compliance Private Limited
| 6178726
| IS 16822 (2019) |
Secondary cells and batteries containing alkaline or other non - Acid electrolytes - Secondary lithium cells and batteries for use in industrial applications |
- |
310000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking and Designation) |
- |
38750 |
|
- |
| 6, 6.1, 6.2(Charging Procedures For Test Purposes) |
- |
38750 |
|
- |
| 6.3, 6.3.1(Discharge Performance, Discharge Performance at +25°C) |
- |
38750 |
|
- |
| 6.3.2(Discharge performance at Low Temperature) |
- |
38750 |
|
- |
| 6.3.3(High Rate Permissible Current) |
- |
38750 |
|
- |
| 6.4(Charge (Capacity) Retention and Recovery) |
- |
38750 |
|
- |
| 6.5(Cell and Battery Internal Resistance) |
- |
38750 |
|
- |
| 6.6(Endurance) |
- |
38750 |
|
- |
|
10 Jul, 2027 |
- Included w.e.f.10.09.2025 |
| 3209 |
ALPHA TEST HOUSE PVT LTD, BAHADURGARH
| 8185306
| IS 16392 (2015) |
Geosynthetics - Geotextiles for permanent erosion control in hard armor systems - Specification |
All |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 4.3 Table 1 (i) (g)(Abrasion strength) |
- |
1000 |
|
- |
| Cl 4.3 Table 1 (i) (d)(Grab strength, N) |
- |
1000 |
|
- |
| Cl 4.3 Table 1 (i) (e)(Sewn seam strength, N) |
- |
1000 |
|
- |
| Cl 4.3 Table 1 (i) (f)(Trapezidal tear strength, N) |
- |
1000 |
|
- |
| Cl 4.3 Table 1 (i) (h)(CBR puncture strength, N) |
- |
1000 |
|
- |
| Cl 4.3 Table 1 (i) (j)(Burst strength, kPa) |
- |
1000 |
|
- |
| Cl 4.3 Table 1 (iii) (a)(Pullout Interaction Coefficient, at 6 mm displacement, Normal load equal to 5 kPa) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (iii) (b)(Coefficient of Direct Shear at peak geotextile shear strength, Normal load equal to 5 kPa) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (i) (a)(Type of geotextile) |
- |
1000 |
|
- |
| Cl 4.3 Table 1 (i) (b)(Roll length, m) |
- |
1000 |
|
- |
| Cl 4.3 Table 1 (i) (c)(Roll width, m) |
- |
1000 |
|
- |
| Cl 4.3 Table 1 (ii) (a)(In-situ soil passing 0.075 mm sieve (IS 200 sieve), Percent, Course) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (ii) (b)(Permitttivity, s-1 , Course) |
- |
2000 |
|
- |
| Cl 4.3 Table 1 (ii) (c)(Apparent Opening Size (AOS), mm, Course) |
- |
2000 |
|
- |
| Cl 4.3 Table 1 (iii) (c)(Resistance to installation damage, Percent retained Strength) |
- |
2000 |
|
- |
| Cl 4.3 Table 1 (iii) (d)(Ultraviolet stability at 500h, retained strength, percent of original strength) |
- |
1000 |
|
- |
| Cl 4.3 Table 1 (ii) (a)(In-situ soil passing 0.075 mm sieve (IS 200 sieve), Percent, Medium) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (ii) (a)(In-situ soil passing 0.075 mm sieve (IS 200 sieve), Percent, Fine) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (ii) (b)(Permitttivity, s-1 , Medium) |
- |
1000 |
|
- |
| Cl 4.3 Table 1 (ii) (b)(Permitttivity, s-1 , Fine) |
- |
1000 |
|
- |
| Cl 4.3 Table 1 (ii) (c)(Apparent Opening Size (AOS), mm, Medium) |
- |
1000 |
|
- |
| Cl 4.3 Table 1 (ii) (c)(Apparent Opening Size (AOS), mm, Fine) |
- |
1000 |
|
- |
| Cl 6(Marking) |
- |
1000 |
|
- |
| Cl 4.3 Table 1 (iii) (a) of Amd-1(Resistance to installation damage, percent retained strength, SC/SW/GP) |
- |
1000 |
|
- |
| 4.2, Amd-1(Carbon Black content & Dispersion) |
- |
1000 |
|
- |
| 4.2, Amd-1(Type of polymer) |
- |
1000 |
|
- |
| 4.2, Amd-1(Isophthalic acid content) |
- |
1000 |
|
- |
| Cl 4.3 Table 1 (i) (g)(Abrasion strength) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (i) (d)(Grab strength, N) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (i) (e)(Sewn seam strength, N) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (i) (f)(Trapezidal tear strength, N) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (i) (h)(CBR puncture strength, N) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (i) (j)(Burst strength, kPa) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (iii) (a)(Pullout Interaction Coefficient, at 6 mm displacement, Normal load equal to 5 kPa) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (iii) (b)(Coefficient of Direct Shear at peak geotextile shear strength, Normal load equal to 5 kPa) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (i) (a)(Type of geotextile) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (i) (b)(Roll length, m) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (i) (c)(Roll width, m) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (ii) (a)(In-situ soil passing 0.075 mm sieve (IS 200 sieve), Percent, Course) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (ii) (b)(Permitttivity, s-1 , Course) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (ii) (c)(Apparent Opening Size (AOS), mm, Course) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (iii) (c)(Resistance to installation damage, Percent retained Strength) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (iii) (d)(Ultraviolet stability at 500h, retained strength, percent of original strength) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (ii) (a)(In-situ soil passing 0.075 mm sieve (IS 200 sieve), Percent, Medium) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (ii) (a)(In-situ soil passing 0.075 mm sieve (IS 200 sieve), Percent, Fine) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (ii) (b)(Permitttivity, s-1 , Medium) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (ii) (b)(Permitttivity, s-1 , Fine) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (ii) (c)(Apparent Opening Size (AOS), mm, Medium) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (ii) (c)(Apparent Opening Size (AOS), mm, Fine) |
- |
0 |
|
- |
| Cl 6(Marking) |
- |
0 |
|
- |
| Cl 4.3 Table 1 (iii) (a) of Amd-1(Resistance to installation damage, percent retained strength, SC/SW/GP) |
- |
0 |
|
- |
| 4.2, Amd-1(Carbon Black content & Dispersion) |
- |
0 |
|
- |
| 4.2, Amd-1(Type of polymer) |
- |
0 |
|
- |
| 4.2, Amd-1(Isophthalic acid content) |
- |
0 |
|
- |
|
08 May, 2028 |
- Included w.e.f.12.09.2025 |
| 3210 |
Hi Physix Laboratory India Private Limited, Pune
| 7126926
| IS/IEC 61730 : PART 2 (2023) |
Photovoltaic (PV) Module - Safety Qualification Part 2 Requirements for Testing (Second Revision) |
- |
1765000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.2(Visual inspection MST 01) |
- |
20000 |
|
- |
| 10.3(Performance at STC MST 02) |
- |
30000 |
|
- |
| 10.4(Maximum power determination MST 03) |
- |
30000 |
|
- |
| 10.5(Insulation thickness test MST 04) |
- |
55000 |
|
- |
| 10.6(Durability of markings MST 05) |
- |
5000 |
|
- |
| 10.7(Sharp edge test MST 06) |
- |
10000 |
|
- |
| 10.8(Bypass diode functionality test MST 07) |
- |
20000 |
|
- |
| 10.9(Accessibility test MST 11) |
- |
5000 |
|
- |
| 10.1(Cut susceptibility test MST 12) |
- |
5000 |
|
- |
| 10.11(Continuity test of equipotential bonding MST 13) |
- |
5000 |
|
- |
| 10.12(Impulse voltage test MST 14) |
- |
30000 |
|
- |
| 10.13(Insulation test MST 16) |
- |
15000 |
|
- |
| 10.14(Wet leakage current test MST 17) |
- |
20000 |
|
- |
| 10.16(Hot-spot endurance test MST 22) |
- |
200000 |
|
- |
| 10.17(Fire test MST 23) |
- |
50000 |
|
- |
| 10.18(Ignitability test MST 24) |
- |
145000 |
|
- |
| 10.19(Bypass diode thermal test MST 25) |
- |
80000 |
|
- |
| 10.20(Reverse current overload test MST 26) |
- |
20000 |
|
- |
| 10.21(Module breakage test MST 32) |
- |
10000 |
|
- |
| 10.22(Screw connections test MST 33) |
- |
5000 |
|
- |
| 10.23(Static mechanical load test MST 34) |
- |
40000 |
|
- |
| 10.24(Peel test MST 35) |
- |
75000 |
|
- |
| 10.25(Lap shear strength test MST 36) |
- |
75000 |
|
- |
| 10.26(Materials creep test MST 37) |
- |
45000 |
|
- |
| 10.27(Robustness of terminations test MST 42) |
- |
15000 |
|
- |
| 10.28(Thermal cycling test MST 51) |
- |
250000 |
|
- |
| 10.29(Humidity freeze test MST 52) |
- |
100000 |
|
- |
| 10.30(Damp heat test MST 53) |
- |
150000 |
|
- |
| 10.31(UV test MST 54) |
- |
150000 |
|
- |
| 10.32(Cold conditioning test MST 55) |
- |
25000 |
|
- |
| 10.33(Dry heat conditioning test MST 56) |
- |
50000 |
|
- |
| 10.34(Evaluation of insulation coordination MST 57) |
- |
30000 |
|
- |
|
20 Jun, 2028 |