| 3751 |
BIS, Central Laboratory (CL)
| None
| IS 10508 (2020) |
Phosphoric Acid, Food Grade - Specification ( Second Revision ) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 3.3, Table-1 (ix) (Copper (as Cu) mg/kg, Max) |
- |
|
|
|
| Clause 3.3, Table-1 (x) (Tin, mg/kg, Max) |
- |
|
|
|
| Clause 3.3, Table-1 (xi) (Cadmium(as Cd), mg/kg, Max) |
- |
|
|
|
| Clause 3.3, Table-1 (xii) (Mercury, mg/kg, Max) |
- |
|
|
|
| Clause 3.3, Table-1 (xiii) (Molybdenum (as Mo),) |
- |
|
|
|
| Clause 3.3, Table-1 (xiv) (Aluminium (as Al)) |
- |
|
|
|
| Cl-3.1 (Description) |
- |
|
|
|
| Cl-3.2 (Test for Phosphate) |
- |
|
|
|
| Cl-3.3, Table-1 (viii) (Lead (as Pb),) |
- |
|
|
|
| Cl-3.3, Table-1 (vii) (Arsenic (as As),) |
- |
|
|
|
| Cl-3.3, Table-1 (v) (Sulphates percent by mass, Max) |
- |
|
|
|
| Cl-3.3, Table-1 (iv) (Chlorides, mg/kg, Max) |
- |
|
|
|
| Cl-3.3, Table-1 (iii) (Volatile acids, mg/kg, Max) |
- |
|
|
|
| Cl-3.3, Table-1 (ii) (Nitrates, mg/kg, Max) |
- |
|
|
|
| Cl-3.3, Table-1 (i) (Purity as H3PO4, percent by mass, Min) |
- |
|
|
|
|
- |
- - |
| 3752 |
BIS, Central Laboratory (CL)
| None
| IS 16098 Part 2 (2013) |
Structured-Wall Plastics Piping Systems for Non-Pressure Drainage and Sewerage Part 2 Pipes and Fittings with Non-Smooth External Surface, Type B |
- |
Rs. 1500.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.3.2 (Length of Pipe) |
- |
|
|
|
|
- |
- - |
| 3753 |
BIS, Central Laboratory (CL)
| None
| IS 16098 Part 1 (2013) |
Structured-Wall Plastics Piping Systems for Non-Pressure Drainage and Sewerage Part 1 Pipes and Fittings With Smooth External Surface, Type A |
- |
Rs. 2100.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.3.1 (Dimension of Pipes and Fittings
Diameter of pipe) |
- |
|
|
|
|
- |
- - |
| 3754 |
TUV SUD SOUTH ASIA PRIVATE LIMITED, BENGALURU
| 6180126
| IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
- |
295000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
10000 |
|
20% Discount to BIS |
| 7(Marking and instructions) |
- |
10000 |
|
20% Discount to BIS |
| 8(Protection against live parts) |
- |
15000 |
|
20% Discount to BIS |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
-- |
| 10(POWER INPUT AND CURRENT) |
- |
15000 |
|
20% Discount to BIS |
| 11(HEATING) |
- |
20000 |
|
20% Discount to BIS |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
15000 |
|
20% Discount to BIS |
| 14(TRANSIENT OVERVOLTAGES) |
- |
10000 |
|
20% Discount to BIS |
| 15(MOISTURE RESISTANCE) |
- |
30000 |
|
20% Discount to BIS |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
15000 |
|
20% Discount to BIS |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
10000 |
|
20% Discount to BIS |
| 18(ENDURANCE) |
- |
0 |
|
-- |
| 19(ABNORMAL OPERATION) |
- |
20000 |
|
20% Discount to BIS |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
15000 |
|
20% Discount to BIS |
| 21(MECHANICAL STRENGTH) |
- |
15000 |
|
20% Discount to BIS |
| 22(CONSTRUCTION) |
- |
20000 |
|
20% Discount to BIS |
| 23(INTERNAL WIRING) |
- |
10000 |
|
20% Discount to BIS |
| 24(COMPONENTS) |
- |
10000 |
|
20% Discount to BIS |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
15000 |
|
20% Discount to BIS |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
10000 |
|
20% Discount to BIS |
| 27(PROVISION FOR EARTHING) |
- |
15000 |
|
20% Discount to BIS |
| 28(SCREWS AND CONNECTIONS) |
- |
10000 |
|
20% Discount to BIS |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
15000 |
|
20% Discount to BIS |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
20000 |
|
20% Discount to BIS |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
20% Discount to BIS |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
500 |
|
20% Discount to BIS |
| 22.16(Automatic cord reel) |
- |
0 |
|
-- |
| 22.32(Oxygen bomb for rubber material) |
- |
0 |
|
-- |
| 22.47(Water pressure inlet) |
- |
5000 |
|
20% Discount to BIS |
| 22.106(Interlocks) |
- |
10000 |
|
20% Discount to BIS |
| 22.3(Flexing test) |
- |
0 |
|
-- |
| 24(Components) |
- |
10000 |
|
20% Discount to BIS |
| 19.11.4.1(Electrostatic discharges) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.2(Radiated fields) |
- |
40000 |
|
20% Discount to BIS |
| 19.11.4.3(Fast transient bursts) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.4(Surge immunity test) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.7(Harmonics) |
- |
15000 |
|
20% Discount to BIS |
| 4(General requirements) |
- |
1000 |
|
20% Discount to BIS |
| 5(General Conditions of tests) |
- |
1000 |
|
20% Discount to BIS |
| 19.11.4.5(Immunity to conducted discharges) |
- |
15000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
-- |
| 7.3(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.4(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.5(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.6(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.7(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.8(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1) |
- |
0 |
|
-- |
| 6(Classification- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| Marking- IS 302-1(Marking- IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
-- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.7(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.8(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.9(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.1O(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.11(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.12(Marking- IS 302-2-15) |
- |
1000 |
|
20% Discount to BIS |
| 7.12(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.12.1(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.12.3(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.12.5(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.12.6(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.13(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.14(Marking- IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 7.15(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.101(Marking- IS 302-2-15) |
- |
1000 |
|
20% Discount to BIS |
| 8(Protection Against Electric Shock, IS 302-1) |
- |
0 |
|
-- |
| 10(Power Input and Current, IS 302-1) |
- |
0 |
|
-- |
| 11(Heating, IS 302-1) |
- |
0 |
|
-- |
| 11(Heating, IS 302-1) |
- |
0 |
|
-- |
| 11(Heating, IS 302-1) |
- |
0 |
|
-- |
| 11(Heating, IS 302-1) |
- |
0 |
|
-- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
0 |
|
-- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
-- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 15.2(Spillage test as 15.2, IS 3.02-1 & 302-2-15) |
- |
10000 |
|
20% Discount to BIS |
| 16(Leakage current as per Cl 16, IS 302-1) |
- |
0 |
|
-- |
| 16(electric strength as per Cl 16, IS 302-1) |
- |
0 |
|
-- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
0 |
|
-- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-2-15) |
- |
15000 |
|
20% Discount to BIS |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
-- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
-- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
-- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
-- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 22.1(Construction, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 22.7(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
10000 |
|
20% Discount to BIS |
| 22.107(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
10000 |
|
20% Discount to BIS |
| 22.108(Construction as per Cl 22.8, IS 3.02-2-15) |
- |
10000 |
|
20% Discount to BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.2(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.4(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.5(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.6(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.7(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.8(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.9(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.1O(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
-- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 27.1(Provision for Earthing, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 27.2(Provision for Earthing, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 27.3(Provision for Earthing, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 27.4(Provision for Earthing, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 27.5(Provision for Earthing, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 28(Screws & Connections, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
20000 |
|
20% Discount to BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 6.0(Classification) |
- |
5000 |
|
20% Discount to BIS |
| 7(Marking and instructions) |
- |
10000 |
|
20% Discount to BIS |
| 8(Protection against live parts) |
- |
10000 |
|
20% Discount to BIS |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
-- |
| 10(POWER INPUT AND CURRENT) |
- |
15000 |
|
20% Discount to BIS |
| 11(HEATING) |
- |
25000 |
|
20% Discount to BIS |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
15000 |
|
20% Discount to BIS |
| 14(TRANSIENT OVERVOLTAGES) |
- |
10000 |
|
20% Discount to BIS |
| 15(MOISTURE RESISTANCE) |
- |
25000 |
|
20% Discount to BIS |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
15000 |
|
20% Discount to BIS |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
15000 |
|
20% Discount to BIS |
| 18(ENDURANCE) |
- |
0 |
|
-- |
| 19(ABNORMAL OPERATION) |
- |
20000 |
|
20% Discount to BIS |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
10000 |
|
20% Discount to BIS |
| 21(MECHANICAL STRENGTH) |
- |
10000 |
|
20% Discount to BIS |
| 22(CONSTRUCTION) |
- |
15000 |
|
20% Discount to BIS |
| 23(INTERNAL WIRING) |
- |
10000 |
|
20% Discount to BIS |
| 24(COMPONENTS) |
- |
15000 |
|
20% Discount to BIS |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
15000 |
|
20% Discount to BIS |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
10000 |
|
20% Discount to BIS |
| 27(PROVISION FOR EARTHING) |
- |
15000 |
|
20% Discount to BIS |
| 28(SCREWS AND CONNECTIONS) |
- |
10000 |
|
20% Discount to BIS |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
10000 |
|
20% Discount to BIS |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
10000 |
|
20% Discount to BIS |
| 31(RESISTANCE TO RUSTING) |
- |
10000 |
|
20% Discount to BIS |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
1000 |
|
20% Discount to BIS |
| 22.16(Automatic cord reel) |
- |
0 |
|
- |
| 22.32(Oxygen bomb for rubber material) |
- |
0 |
|
- |
| 22.47(Water pressure inlet) |
- |
5000 |
|
20% Discount to BIS |
| 22.106(Interlocks) |
- |
5000 |
|
20% Discount to BIS |
| 22.3(Flexing test) |
- |
0 |
|
-- |
| 24(Components) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.1(Electrostatic discharges) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.2(Radiated fields) |
- |
40000 |
|
20% Discount to BIS |
| 19.11.4.3(Fast transient bursts) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.4(Surge immunity test) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.7(Harmonics) |
- |
15000 |
|
20% Discount to BIS |
| 4(General requirements) |
- |
1000 |
|
20% Discount to BIS |
| 5(General Conditions of tests) |
- |
1000 |
|
20% Discount to BIS |
| 19.11.4.5(Immunity to conducted discharges) |
- |
15000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1) |
- |
9 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.4(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.5(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.6(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.7(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.8(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| Marking- IS 302-1(Marking- IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.9(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1O(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 7.15(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.101(Marking- IS 302-2-15) |
- |
1000 |
|
20% Discount to BIS |
| 8(Protection Against Electric Shock, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 10(Power Input and Current, IS 302-1) |
- |
15000 |
|
- |
| 11(Heating, IS 302-1) |
- |
25000 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
15000 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
15000 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
10000 |
|
- |
| 15.2(Spillage test as 15.2, IS 3.02-1 & 302-2-15) |
- |
10000 |
|
20% Discount to BIS |
| 16(Leakage current as per Cl 16, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 16(electric strength as per Cl 16, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 19.13(Abnormal Operation as per Cl 19, IS 302-2-15) |
- |
15000 |
|
20% Discount to BIS |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 21.1(Mechanical Strength, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 21.2(Mechanical Strength, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 22.1(Construction, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 22.7(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
10000 |
|
20% Discount to BIS |
| 22.107(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
10000 |
|
20% Discount to BIS |
| 22.108(Construction as per Cl 22.8, IS 3.02-2-15) |
- |
10000 |
|
20% Discount to BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.2(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.4(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.5(Internal Wiring, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 23.6(Internal Wiring, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 23.7(Internal Wiring, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 23.8(Internal Wiring, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 23.9(Internal Wiring, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 23.1O(Internal Wiring, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 27.1(Provision for Earthing, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 27.2(Provision for Earthing, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 27.3(Provision for Earthing, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 27.4(Provision for Earthing, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 27.5(Provision for Earthing, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 28(Screws & Connections, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| Cl. 15.02(stands for cordless kettles) |
- |
5000 |
|
20% Discount to BIS |
| Cl.22.103(appliance coupler of cordless kettles) |
- |
10000 |
|
20% Discount to BIS |
| 6.0(Classification) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8(Protection against live parts) |
- |
0 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
0 |
|
- |
| 11(HEATING) |
- |
0 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
0 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
0 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
0 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
0 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
0 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
0 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
0 |
|
- |
| 22(CONSTRUCTION) |
- |
0 |
|
- |
| 23(INTERNAL WIRING) |
- |
0 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
0 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
0 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
0 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
0 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
0 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
0 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
0 |
|
- |
| 22.16(Automatic cord reel) |
- |
0 |
|
- |
| 22.32(Oxygen bomb for rubber material) |
- |
0 |
|
- |
| 22.47(Water pressure inlet) |
- |
0 |
|
- |
| 22.106(Interlocks) |
- |
0 |
|
- |
| 22.3(Flexing test) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 4(General requirements) |
- |
0 |
|
- |
| 5(General Conditions of tests) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| Marking- IS 302-1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.9(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1O(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.101(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 8(Protection Against Electric Shock, IS 302-1) |
- |
0 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
0 |
|
- |
| 15.2(Spillage test as 15.2, IS 3.02-1 & 302-2-15) |
- |
0 |
|
- |
| 16(Leakage current as per Cl 16, IS 302-1) |
- |
0 |
|
- |
| 16(electric strength as per Cl 16, IS 302-1) |
- |
0 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-2-15) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.7(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
0 |
|
- |
| 22.107(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
0 |
|
- |
| 22.108(Construction as per Cl 22.8, IS 3.02-2-15) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.1O(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
0 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
0 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
0 |
|
- |
| Cl. 15.02(stands for cordless kettles) |
- |
0 |
|
- |
| Cl.22.103(appliance coupler of cordless kettles) |
- |
0 |
|
- |
| Cl-19.3(Abnormal operation test) |
- |
0 |
|
- |
| Cl-19.101("Abnormal operation test
") |
- |
0 |
|
- |
| Cl-19.102("Abnormal operation test
") |
- |
0 |
|
- |
| Cl-19.103("Abnormal operation test
") |
- |
0 |
|
- |
| Cl-22.103(Construction) |
- |
0 |
|
- |
| Cl-25.101(" Supply connection And external flexible ") |
- |
0 |
|
- |
|
11 Sep, 2027 |
- Included w.e.f 12.11.2025
Exclusion: Cl 8 (Protection against live parts), 22.16 (Automatic cord reel), 22.32 (Oxygen bomb for rubber material), Cl. 23.3 (Flexing test), Cl.22.48 (Appliances connected to the water mains) |
| 3755 |
BIS, Central Laboratory (CL)
| None
| IS 14885 (2022) |
Polyethylene Pipes for the Supply of Gaseous Fuels � Specification (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2 (Grade of material) |
- |
|
|
|
|
- |
- - |
| 3756 |
BIS, Central Laboratory (CL)
| None
| IS 17546 (2021) |
Chlorinated polyvinyl chloride CPVC fittings for potable hot and cold water distribution supplies Specification |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1 (Nominal Size(DN)) |
- |
|
|
|
| 3.2 (Nominal Outside Diameter) |
- |
|
|
|
| 3.3 (Mean Inside Diameter of Socket at Entry) |
- |
|
|
|
| 3.4 (Mean Inside Diameter of Socket at Shoulder (Bottom)) |
- |
|
|
|
| 3.5 (Out-of-Roundness (Ovality)) |
- |
|
|
|
| 3.6 (Nominal Wall Thickness) |
- |
|
|
|
| 3.7 (Minimum Wall Thickness) |
- |
|
|
|
| 3.9 (Working Pressure) |
- |
|
|
|
| 3.1 (Standard Dimension Ratio) |
- |
|
|
|
| 7 (Dimensions of fitting) |
- |
|
|
|
| 8.2 (Opacity) |
- |
|
|
|
| 8.1 (Visual Appearance) |
- |
|
|
|
| 8.3 (Stress Relief Test) |
- |
|
|
|
| 8.4 (Vicat softening Temperature) |
- |
|
|
|
| 8.5 (Density) |
- |
|
|
|
| 11 (Marking) |
- |
|
|
|
|
- |
- - |
| 3757 |
BIS, Central Laboratory (CL)
| None
| IS 13488 (2008) |
Irrigation equipment - Emitting pipe systems - Specification (First Revision) |
- |
Testing charges for the product: Rs. 9731 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1 (Materials - shall be resistant to fertilizers and
chemicals commonly employed in irrigation, and shall
be suitable for use with water at temperatures up to
60°C and at pressures designed for the emitting pipe) |
- |
|
|
|
| 5.1.2 (Ref. Cl 4.1.c.i of IS 12786 : 1989) (Density) |
- |
|
|
|
| 8.1.3 (Uniformity of Emission Rate for Regulated Emitting Pipes) |
- |
|
|
|
| 8.5 (Resistance to Tension at Elevated Temperature) |
- |
|
|
|
| 4.2 (Carbon black content) |
- |
|
|
|
| 4.2 (Carbon black dispersion) |
- |
|
|
|
| 4.1 d (MFI @ 1900C/2.16 Kg) |
- |
|
|
|
| 6.1.1, Table 1,(i) (Nominal Diameter) |
- |
|
|
|
| 6.1.1, Table 1,(iv) (Wall Thickness) |
- |
|
|
|
|
- |
- - |
| 3758 |
BIS, Central Laboratory (CL)
| None
| IS 711 (2023) |
FERRIC CHLORIDE TECHNICAL SPECIFICATION |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1 (Description) |
- |
|
|
|
| Cl-4.2, Table-1 (i) (Relative Density at 25o/25 oC, Min) |
- |
|
|
|
| Cl-4.2, Table-1 (ii) (Ferric chloride (as FeC13), percent by weight, Min) |
- |
|
|
|
| Cl-4.2, Table-1 (iii) ("Free acid (HCl), percent by weight, Max or
Basicity (as Fe2O3), percent by weight, Max") |
- |
|
|
|
| Cl-4.2, Table-1 (iv) (Ferrous salts (as FeCl2), percent by weight, Max) |
- |
|
|
|
| Cl-4.2, Table-1 (v) (Insoluble matter, percent by weight, Max) |
- |
|
|
|
| Cl-4.2, Table-1 (vi) (Free chlorine (as C1), percent by weight, Max) |
- |
|
|
|
| Cl-4.2, Table-1 (vii) (Sulphates (as SO4), percent by weight, Max) |
- |
|
|
|
| Cl-4.2, Table-1 (viii) (Nitrates (as NO3), percent by weight, Max) |
- |
|
|
|
| Cl-4.2, Table-1 (ix) (Alkalis and alkaline earths (expressed as sulphates), percent by weight, Max) |
- |
|
|
|
| Cl-4.2, Table-1 (x) (Copper as (Cu), percent by weight, Max) |
- |
|
|
|
| Cl-4.2, Table-1 (xi) (Zinc (as Zn ), percent by weight, Max) |
- |
|
|
|
| Cl-4.2, Table-1 (xii) (Arsenic (as As2O3), ppm, Max) |
- |
|
|
|
| Cl-4.2, Table-1 (xiv) (Cadmium (as Cd), ppm, Max) |
- |
|
|
|
| Cl-4.2, Table-1 (xv) (Chromium (as Cr), ppm, Max) |
- |
|
|
|
| Cl-4.2, Table-1 (xvi) (Lead (as Pb), ppm, Max) |
- |
|
|
|
| Cl-4.2, Table-1 (xviii) (Nickel (as Ni), ppm, Max) |
- |
|
|
|
| Cl-4.2, Table-1 (xix) (Selenium (as Se), ppm, Max) |
- |
|
|
|
|
- |
- - |
| 3759 |
Indian Institute of Packaging (IIP), Mumbai
| 7118404
| IS 2508 (2024) |
Polyethylene Films and Sheets â Specification (Fourth Revision) |
- |
5760 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.4 Sl No. (i) of Table 1, Table 2, Table 3 & Table 4.(Density - IS 13360 : Part 3 : Sec 10 : 2021) |
- |
0 |
|
- |
| 5.1.6(Black Film- Carbon black - IS 2508:2024) |
- |
0 |
|
- |
| 5.1.6(Ash content - IS 2508: 2024) |
- |
0 |
|
- |
| 5.1.6(carbon black dispersion - IS 2530: 1963) |
- |
0 |
|
- |
| 5.1.1(Appearance) |
- |
0 |
|
- |
| 5.1.2(Film Form) |
- |
0 |
|
- |
| 5.1.3(Odour) |
- |
0 |
|
- |
| 5.1.5(Melt Flow Index- IS 13360 : Part 4 : Sec 1 : subsec 1 or IS 13360 : Part 4 : Sec 1 : subsec 2) |
- |
0 |
|
- |
| 5.2.1.1/ Table-1,2,3 &4(Nominal Thickness, Annex C,) |
- |
0 |
|
- |
| 5.2.1.2(Nominal Width) |
- |
0 |
|
- |
| 6, Type 1 (LDPE/LLDPE) /Table-1("Tensile strength at break-Machine direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| 6/Table-1("Tensile strength at break-Transverse direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| 6/Table-1("Elongation % at break, -Machine direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| 6/Table-1("Elongation % at break, -Transverse direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| 6/Table-1("Ageing test at (70 ± 1) ºC for 7 days-Machine Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 6/Table-1("Ageing test at (70 ± 1) ºC for 7 days- Transverse Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 6/Table-1(Dart impact strength,Method B of IS 13360 (Part 5/Sec 6)) |
- |
0 |
|
- |
| 6/Table-1(Tear resistance -Machine direction, IS 13360 (Part 5/Sec 23)) |
- |
0 |
|
- |
| 6/Table-1(Tear resistance-Transverse direction, IS 13360 (Part 5/Sec 23)) |
- |
0 |
|
- |
| " 7, Type 2 (HDPE/PE) /Table-2"("Tensile strength at break-Machine direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| " 7/Table-2"("Tensile strength at break-Transverse direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| " 7/Table-2"("Elongation % at break, -Machine direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| " 7/Table-2"("Elongation % at break, -Transverse direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| " 7/Table-2"("Ageing test at (70 ± 1) ºC for 7 days-Machine Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| " 7/Table-2"("Ageing test at (70 ± 1) ºC for 7 days- Transverse Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| " 7/Table-2"(Dart impact strength,Method B of IS 13360 (Part 5/Sec 6)) |
- |
0 |
|
- |
| 8, Type 3 (LDPE/LLDPE, PE) /Table-3("Average Tensile Break strength- Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 8/Table-3("Average Tensile Break strength- Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 8/Table-3("Average Tensile Break Elongation %-Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 8/Table-3("Average Tensile Break Elongation %-Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 8/Table-3(Average Tear resistance, IS 2508: 2024 Annex-D) |
- |
0 |
|
- |
| 8/Table-3(Average Puncture resistance, IS 2508: 2024 Annex-E) |
- |
0 |
|
- |
| 9, Type 4 (HDPE/PE) /Table-4("Average Yield strength- Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 9/Table-4("Average Yield strength- Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 9/Table-4("Average Tensile Break strength- Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 9/Table-4("Average Tensile Break strength- Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 9/Table-4("Average Tensile yield Elongation %-Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 9/Table-4("Average Tensile yield Elongation %-Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 9/Table-4(Average Tensile Break Elongation %-Machine Direction, IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)) |
- |
0 |
|
- |
| 9/Table-4(Average Tensile Break Elongation -Transverse Direction, IS 13360 (Part 5/Sec 1) and S 13360 (Part 5/Sec 3)) |
- |
0 |
|
- |
| 9/Table-4(Average Tear resistance, IS 2508: 2024 Annex-D) |
- |
0 |
|
- |
|
30 Jun, 2028 |
- Included w.e.f 12.09.2025 |
| 3760 |
ALPHA TEST HOUSE PVT LTD, BAHADURGARH
| 8185306
| IS 14756 (2024) |
Stainless Steel Utensils - Specification (THIRD REVISION) |
ALL |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 3.1(Material used for manufacturing utensils) |
- |
100 |
|
- |
| Cl 3.2(Material used for composite bottom) |
- |
100 |
|
- |
| Cl 3.3(Material used for body of utensil of 3-ply construction) |
- |
100100 |
|
- |
| Cl 3.4(Material used for stainless steel lid) |
- |
100 |
|
- |
| Cl 3.5(Material used for tempered glass lid) |
- |
100 |
|
- |
| Cl 3.5(Material used for stainless steel rim) |
- |
100 |
|
- |
| Cl 4.2 & Table 1(Minimum Sheet Thickness for Body of Utensil) |
- |
100 |
|
- |
| Cl 4.2 & Table 2(Minimum Sheet Thickness for Lid of Utensil) |
- |
100 |
|
- |
| Cl 4.2(Thickness of the finished utensil) |
- |
100 |
|
- |
| Cl 4.3(Classification) |
- |
100 |
|
- |
| Cl 4.4 (i)(Thickness of Aluminium disc/core) |
- |
100 |
|
- |
| Cl 4.4 (ii)(Thickness of Protector/cowl) |
- |
100 |
|
- |
| Cl 4.5(Minimum sheet thickness (3-ply utensil)) |
- |
100 |
|
- |
| Cl 4.5(Thickness of finished utensil (3-ply utensil)) |
- |
100 |
|
- |
| Cl 5.1(Manufacturing defect & visual appearance) |
- |
100 |
|
- |
| CL 5.2(Accessibility for cleaning) |
- |
100 |
|
- |
| Cl 5.3(Joining of handles to the utensils) |
- |
100 |
|
- |
| Cl 5.4(Requirement for handles) |
- |
100 |
|
- |
| Cl 5.5(Welding (Finish)) |
- |
100 |
|
- |
| Cl 5.6(Finish of 3-ply utensil) |
- |
100 |
|
- |
| Cl 5.7(Requirement for coating) |
- |
100 |
|
- |
| Cl 5.8(Coating thickness test) |
- |
100 |
|
- |
| Cl 5.8(Coating adhesion test) |
- |
100 |
|
- |
| Cl 5.8.1(Thermal shock test (Coating)) |
- |
100 |
|
- |
| Cl 6.1(Staining Test (Type Test - Frequency Once in a Year)) |
- |
100 |
|
- |
| Cl 6.2(Mechanical Shock Test (for Cladded Utensils Only)) |
- |
100 |
|
- |
| Cl 6.3(Thermal Shock Test (for Cladded Utensils Only)) |
- |
100 |
|
- |
| Cl 6.4(Dry Heat Test (for Cladded Utensils Only)) |
- |
100 |
|
- |
| Cl 6.5(Coating Thickness Test (for Copper Deposit)) |
- |
100 |
|
- |
| Cl 6.6(Thermal shock test (3-ply construction utensil body)) |
- |
100 |
|
- |
| Cl 6.7(Nominal Capacity Test) |
- |
100 |
|
- |
| Cl 8(Marking) |
- |
100 |
|
- |
| 3.1(a) Carbon) |
- |
100 |
|
- |
| 3.1(b) Silicon) |
- |
100 |
|
- |
| 3.1(c)Manganese) |
- |
100 |
|
- |
| 3.1(d) Nickel) |
- |
100 |
|
- |
| 3.1(Chromium) |
- |
100 |
|
- |
| 3.1(Sulphu) |
- |
100 |
|
- |
| 3.1(Phosphorus) |
- |
100 |
|
- |
| Stainless Steel Utensils - Specification (THIRD REVISION)(Copper) |
- |
100 |
|
- |
| 3.1(Nitrogen) |
- |
100 |
|
- |
| 3.2 a(a) Carbon) |
- |
100 |
|
- |
| 3.2 a(b) Silicon) |
- |
100 |
|
- |
| 68995(Manganese) |
- |
100 |
|
- |
| 3.2 a(d) Nickel) |
- |
100 |
|
- |
| 3.2 a(Chromium) |
- |
100 |
|
- |
| 3.2 a(Sulphur) |
- |
100 |
|
- |
| 3.2 a(g) Phosphorus) |
- |
100 |
|
- |
| 3.2 a(h) Copper) |
- |
100 |
|
- |
| 3.2 a(Nitrogen) |
- |
100 |
|
- |
| 3.2 b(a) Aluminium) |
- |
100 |
|
- |
| 3.2 b(b) Copper) |
- |
100 |
|
- |
| 3.2 b(c) Magnesium) |
- |
100 |
|
- |
| 3.2 b(d) Silicon) |
- |
100 |
|
- |
| 3.2 b(e) Iron) |
- |
100 |
|
- |
| 3.2 b(f) Manganese) |
- |
100 |
|
- |
| 3.2 b(d) Silicon) |
- |
100 |
|
- |
| 3.2 b(e) Iron) |
- |
100 |
|
- |
| 3.2 b(f) Manganese) |
- |
100 |
|
- |
| 3.2 b(g) Zinc) |
- |
100 |
|
- |
| 3.2 b(h) Titanium) |
- |
100 |
|
- |
| 3.2 b(i) Chromium) |
- |
100 |
|
- |
| 3.2 b(j) Cu+Si+Fe+Mn+Zn+mg) |
- |
100 |
|
- |
| 3.2 b(k) Lead) |
- |
100 |
|
- |
| 3.2 c(a) Carbon) |
- |
100 |
|
- |
| 3.2 c(b) Silicon) |
- |
100 |
|
- |
| 3.2 c(c) Manganese) |
- |
100 |
|
- |
| 3.2 c(d) Nickel) |
- |
100 |
|
- |
| 3.2 c(e) Chromium) |
- |
100 |
|
- |
| 3.2 c(f) Sulphur) |
- |
100 |
|
- |
| 3.2 c(g) Phosphorus) |
- |
100 |
|
- |
| 3.3(a) Inner layer) |
- |
100 |
|
- |
| 3.3(b) Middlelayer) |
- |
100 |
|
- |
| 3.3(c) Outerlayer) |
- |
100 |
|
- |
| 3.4(a) Carbon) |
- |
100 |
|
- |
| 3.4(b) Silicon) |
- |
100 |
|
- |
| 3.4(c) Manganese) |
- |
100 |
|
- |
| 3.4(d) Nickel) |
- |
100 |
|
- |
| 3.4(e) Chromium) |
- |
100 |
|
- |
| 3.4(f) Sulphur) |
- |
100 |
|
- |
| 3.4(g) Phosphorus) |
- |
100 |
|
- |
| 3.4(h) Copper) |
- |
100 |
|
- |
| 3.4(i) Nitrogen) |
- |
100 |
|
- |
| 3.4(Thickness stainless steel lid) |
- |
100 |
|
- |
| 3.5(If the utensils provided with tempered glass lid) |
- |
100 |
|
- |
| 4.1(Shapes and Dimensions) |
- |
100 |
|
- |
| 4.2(Thickness of the sheet) |
- |
100 |
|
- |
| 4.3(Classifications) |
- |
100 |
|
- |
| 4.3(Core Thickness for 3-ply Construction
(asper IS15960)) |
- |
100 |
|
- |
| 4.3(Thickness of protective layer (as per IS 15960)) |
- |
100 |
|
- |
| 4.4(Thickness of 3ply full body utensil) |
- |
100 |
|
- |
| 5(Workmanship and finish) |
- |
100 |
|
- |
| 5.4(Handles) |
- |
100 |
|
- |
| 4.1 of IS 13395(Construction) |
- |
100 |
|
- |
| 4.2 of IS 13395(Materials) |
- |
100 |
|
- |
| 4.3 of IS 13395(Selection and Size) |
- |
100 |
|
- |
| 4.4 of Is 13395(Position of Handle and Knob with Respect to Cookware) |
- |
100 |
|
- |
| 4.5 of IS 13395(Attachment to Cookware) |
- |
100 |
|
- |
| 5.2 of IS 13395(Bending Strength) |
- |
100 |
|
- |
| 5.3 of IS 13395(Torque Strength) |
- |
100 |
|
- |
| 5.4 of IS 13395(Impact Strength) |
- |
100 |
|
- |
| 5.5 of IS 13395(Fatigue Resistance
15 000 cycles withstand) |
- |
100 |
|
- |
| 5.6 of IS 13395(Leakage) |
- |
100 |
|
- |
| 5.7 of IS 13395(Thermal Insulation) |
- |
100 |
|
- |
| 5.8 of IS 13395(Heat Resistance) |
- |
100 |
|
- |
| 5.9 of IS 13395(Washing Resistance) |
- |
100 |
|
- |
| 5.10 of IS 13395(Burning Resistance) |
- |
100 |
|
- |
| 5.5(Material comes in contact with food) |
- |
100 |
|
- |
| 6.1(Staining Test) |
- |
100 |
|
- |
| 6.2(Mechanical Shock Test) |
- |
100 |
|
- |
| 6.3(Thermal Shock Test) |
- |
100 |
|
- |
| 6.4(Dry Heat Test) |
- |
100 |
|
- |
| 6.6(Heat test) |
- |
100 |
|
- |
| 6.7.1(Nominal Capacity Test) |
- |
100 |
|
- |
| 6.7.2(Internal diameter of utensil) |
- |
100 |
|
- |
| Annex C(Test for leaching) |
- |
100 |
|
- |
| Annex C(Sensorial test) |
- |
100 |
|
- |
|
08 May, 2028 |
- Included w.e.f 14.08.2025 |
| 3761 |
Aaditech Test and Calibration Lab LLP
| 8179926
| IS 7809 : Part 3 : Sec 1 (1986) |
Specification for pressure sensitive adhesive insulating tapes for electrical purposes: Part 3 requirements or individual materials: Sec 1 plasticized polyvinylchloride tapes with non - Thermosetting adhesive (First Revision) |
This standard (Part 3/Sec 1) covers requirements for pressure sensitive adhesive tapes made of plasticized PVC with a non-thermosetting adhesive. |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
500 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 2.1.1(Type and Desiganation) |
- |
500 |
|
- |
| 2.1.2(Type and Desiganation) |
- |
0 |
|
- |
| 3.1(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
1000 |
|
- |
| 3.2(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
- |
| 3.3(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
- |
| 3.4(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
- |
| 4.1(Performance Requirments) |
- |
500 |
|
- |
| 4.2(Performance Requirments) |
- |
500 |
|
- |
| 4.3(Performance Requirments) |
- |
500 |
|
- |
| 4.4(Performance Requirments) |
- |
500 |
|
- |
| 4.5(Performance Requirments) |
- |
500 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
500 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
500 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
500 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
500 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
2000 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
- |
| 4.8(Stability to accelerated ageing ) |
- |
1000 |
|
- |
| 4.9(Insulation resistance test) |
- |
500 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
500 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 2.1.1(Type and Desiganation) |
- |
0 |
|
- |
| 2.1.2(Type and Desiganation) |
- |
0 |
|
- |
| 3.1(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
500 |
|
- |
| 3.2(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
500 |
|
- |
| 3.3(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
500 |
|
- |
| 3.4(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
500 |
|
- |
| 4.1(Performance Requirments) |
- |
500 |
|
- |
| 4.2(Performance Requirments) |
- |
500 |
|
- |
| 4.3(Performance Requirments) |
- |
500 |
|
- |
| 4.4(Performance Requirments) |
- |
500 |
|
- |
| 4.5(Performance Requirments) |
- |
500 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
500 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
500 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
- |
| 4.8(Stability to accelerated ageing ) |
- |
500 |
|
- |
| 4.9(Insulation resistance test) |
- |
100 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Appearance) |
- |
0 |
|
- |
| 3.1(Freedom from defects) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| Cl.No.4 of IS 7809 (Part 1)-1975(Appearance) |
- |
0 |
|
- |
| Cl.No.5 of IS 7809 (Part 1)-1975(Freedom From Deffects) |
- |
500 |
|
- |
| Cl.No.3.2(Width) |
- |
500 |
|
- |
| Cl.No.3.3(Length) |
- |
500 |
|
- |
| Cl.No.3.4(Thickness) |
- |
500 |
|
- |
| Cl.No.4.1(Tensile Strength) |
- |
500 |
|
- |
| Cl.No.4.2(Adhesion to Steel) |
- |
500 |
|
- |
| Cl.No.4.3(Adhesion to backing) |
- |
500 |
|
- |
| Cl.No.4.4(Electric Strength at RT) |
- |
500 |
|
- |
| Cl.No.4.5(Electric Strength after Humid Conditioning) |
- |
500 |
|
- |
| Cl.No.4.6(Flammability) |
- |
500 |
|
- |
| Cl.No.4.7() |
- |
500 |
|
- |
| Cl.No.4.8(Stability to accelerated ageing) |
- |
500 |
|
- |
| Cl.No.4.9(Insulation Resistance) |
- |
1000 |
|
- |
| Cl.No.7 of IS 7809 (Part 1)-1975(Minimum Storage Life) |
- |
500 |
|
- |
| Cl.No.4 of IS 7809 (Part 1)-1975(Appearance after minimum storage Life) |
- |
500 |
|
- |
| Cl.No.5 of IS 7809 (Part 1)-1975(Freedom From Deffects after minimum storage Life) |
- |
500 |
|
- |
| Cl.No.3.2(Width after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.3.3(Length after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.3.4(Thickness after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.1(Tensile Strength after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.2(Adhesion to Steel after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.3(Adhesion to backing after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.4(Electric Strength at RT after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.5(Electric Strength after Humid Conditioning after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.6(Flammability after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.7(Electrolytic Corrosion after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.8(Stability to accelerated ageing after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.9(Insulation Resistance after minimum storage Life) |
- |
0 |
|
- |
| 3.1(Marking) |
- |
0 |
|
- |
| Cl 9 of IS 7809- 1-1975(Marking) |
- |
0 |
|
- |
| Cl. 4.1 of IS 7809-1-1975(Appearance) |
- |
0 |
|
- |
| Cl. 4.1 of IS 7809-1-1976(Minimum life storage test) |
- |
0 |
|
- |
| Cl. 5.1 of IS 7809-1-1975(Freedom from defects) |
- |
0 |
|
- |
| Cl-4 of IS:7809, Pt-I(Appearance) |
- |
0 |
|
- |
| Cl-5 of IS:7809, Pt-I(Freedom from Defects) |
- |
0 |
|
- |
| Cl 9.1 of IS:7809, Pt-I(Marking) |
- |
500 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 2.1.1(Type and Desiganation) |
- |
0 |
|
- |
| 2.1.2(Type and Desiganation) |
- |
0 |
|
- |
| 3.1(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
500 |
|
- |
| 3.2(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
500 |
|
- |
| 3.3(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
500 |
|
- |
| 3.4(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
500 |
|
- |
| 4.1(Performance Requirments) |
- |
500 |
|
- |
| 4.2(Performance Requirments) |
- |
500 |
|
- |
| 4.3(Performance Requirments) |
- |
500 |
|
- |
| 4.4(Performance Requirments) |
- |
500 |
|
- |
| 4.5(Performance Requirments) |
- |
500 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
500 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
500 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
500 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
500 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
500 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
500 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
500 |
|
- |
| 4.8(Stability to accelerated ageing ) |
- |
500 |
|
- |
| 4.9(Insulation resistance test) |
- |
500 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
500 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 2.1.1(Type and Desiganation) |
- |
0 |
|
- |
| 2.1.2(Type and Desiganation) |
- |
0 |
|
- |
| 3.1(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
- |
| 3.2(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
- |
| 3.3(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
- |
| 3.4(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
- |
| 4.1(Performance Requirments) |
- |
0 |
|
- |
| 4.2(Performance Requirments) |
- |
0 |
|
- |
| 4.3(Performance Requirments) |
- |
0 |
|
- |
| 4.4(Performance Requirments) |
- |
0 |
|
- |
| 4.5(Performance Requirments) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
- |
| 4.8(Stability to accelerated ageing ) |
- |
0 |
|
- |
| 4.9(Insulation resistance test) |
- |
0 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Appearance) |
- |
0 |
|
- |
| 3.1(Freedom from defects) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| Cl.No.4 of IS 7809 (Part 1)-1975(Appearance) |
- |
0 |
|
- |
| Cl.No.5 of IS 7809 (Part 1)-1975(Freedom From Deffects) |
- |
500 |
|
- |
| Cl.No.3.2(Width) |
- |
500 |
|
- |
| Cl.No.3.3(Length) |
- |
500 |
|
- |
| Cl.No.3.4(Thickness) |
- |
500 |
|
- |
| Cl.No.4.1(Tensile Strength) |
- |
500 |
|
- |
| Cl.No.4.2(Adhesion to Steel) |
- |
500 |
|
- |
| Cl.No.4.3(Adhesion to backing) |
- |
400 |
|
- |
| Cl.No.4.4(Electric Strength at RT) |
- |
400 |
|
- |
| Cl.No.4.5(Electric Strength after Humid Conditioning) |
- |
400 |
|
- |
| Cl.No.4.6(Flammability) |
- |
500 |
|
- |
| Cl.No.4.7() |
- |
500 |
|
- |
| Cl.No.4.8(Stability to accelerated ageing) |
- |
500 |
|
- |
| Cl.No.4.9(Insulation Resistance) |
- |
500 |
|
- |
| Cl.No.7 of IS 7809 (Part 1)-1975(Minimum Storage Life) |
- |
500 |
|
- |
| Cl.No.4 of IS 7809 (Part 1)-1975(Appearance after minimum storage Life) |
- |
500 |
|
- |
| Cl.No.5 of IS 7809 (Part 1)-1975(Freedom From Deffects after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.3.2(Width after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.3.3(Length after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.3.4(Thickness after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.1(Tensile Strength after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.2(Adhesion to Steel after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.3(Adhesion to backing after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.4(Electric Strength at RT after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.5(Electric Strength after Humid Conditioning after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.6(Flammability after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.7(Electrolytic Corrosion after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.8(Stability to accelerated ageing after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.9(Insulation Resistance after minimum storage Life) |
- |
0 |
|
- |
| 3.1(Marking) |
- |
0 |
|
- |
| Cl 9 of IS 7809- 1-1975(Marking) |
- |
500 |
|
- |
| Cl. 4.1 of IS 7809-1-1975(Appearance) |
- |
0 |
|
- |
| Cl. 4.1 of IS 7809-1-1976(Minimum life storage test) |
- |
0 |
|
- |
| Cl. 5.1 of IS 7809-1-1975(Freedom from defects) |
- |
0 |
|
- |
| Cl-4 of IS:7809, Pt-I(Appearance) |
- |
0 |
|
- |
| Cl-5 of IS:7809, Pt-I(Freedom from Defects) |
- |
0 |
|
- |
| Cl 9.1 of IS:7809, Pt-I(Marking) |
- |
0 |
|
- |
|
- |
- Included w.e.f 14.08.2025 |
| 3762 |
Excel Surveyors Pvt. Ltd., Kolkata
| 5135906
| IS 2508 (2024) |
Polyethylene Films and Sheets â Specification (Fourth Revision) |
Type I - IV |
5600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.1(Appearance) |
- |
100 |
|
- |
| 5.1.2(Film Form) |
- |
100 |
|
- |
| 5.1.3(Odour) |
- |
100 |
|
- |
| 5.1.5(Melt Flow Index- IS 13360 : Part 4 : Sec 1 : subsec 1 or IS 13360 : Part 4 : Sec 1 : subsec 2) |
- |
400 |
|
- |
| 5.2.1.1/ Table-1,2,3 &4(Nominal Thickness, Annex C,) |
- |
150 |
|
- |
| 5.2.1.2(Nominal Width) |
- |
150 |
|
- |
| 5.1.4 Sl No. (i) of Table 1, Table 2, Table 3 & Table 4.(Density - IS 13360 : Part 3 : Sec 10 : 2021) |
- |
300 |
|
- |
| 5.1.6(Black Film- Carbon black - IS 2508:2024) |
- |
300 |
|
- |
| 5.1.6(Ash content - IS 2508: 2024) |
- |
500 |
|
- |
| 5.1.6(carbon black dispersion - IS 2530: 1963) |
- |
600 |
|
- |
| 6, Type 1 (LDPE/LLDPE) /Table-1("Tensile strength at break-Machine direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
600 |
|
- |
| 6/Table-1("Tensile strength at break-Transverse direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| 6/Table-1("Elongation % at break, -Machine direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| 6/Table-1("Elongation % at break, -Transverse direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| 6/Table-1("Ageing test at (70 ± 1) ºC for 7 days-Machine Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
1200 |
|
- |
| 6/Table-1("Ageing test at (70 ± 1) ºC for 7 days- Transverse Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 6/Table-1(Dart impact strength,Method B of IS 13360 (Part 5/Sec 6)) |
- |
500 |
|
- |
| 6/Table-1(Tear resistance -Machine direction, IS 13360 (Part 5/Sec 23)) |
- |
600 |
|
- |
| 6/Table-1(Tear resistance-Transverse direction, IS 13360 (Part 5/Sec 23)) |
- |
0 |
|
The test charges will be 5600/- for type I |
| " 7, Type 2 (HDPE/PE) /Table-2"("Tensile strength at break-Machine direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
600 |
|
- |
| " 7/Table-2"("Tensile strength at break-Transverse direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| " 7/Table-2"("Elongation % at break, -Machine direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| " 7/Table-2"("Elongation % at break, -Transverse direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| " 7/Table-2"("Ageing test at (70 ± 1) ºC for 7 days-Machine Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
1200 |
|
- |
| " 7/Table-2"("Ageing test at (70 ± 1) ºC for 7 days- Transverse Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| " 7/Table-2"(Dart impact strength,Method B of IS 13360 (Part 5/Sec 6)) |
- |
500 |
|
The test charges will be 5000/- for type II |
| 8, Type 3 (LDPE/LLDPE, PE) /Table-3("Average Tensile Break strength- Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
600 |
|
- |
| 8/Table-3("Average Tensile Break strength- Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 8/Table-3("Average Tensile Break Elongation %-Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 8/Table-3("Average Tensile Break Elongation %-Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 8/Table-3(Average Tear resistance, IS 2508: 2024 Annex-D) |
- |
600 |
|
- |
| 8/Table-3(Average Puncture resistance, IS 2508: 2024 Annex-E) |
- |
500 |
|
The test charges will be 4400/- for type III |
| 9, Type 4 (HDPE/PE) /Table-4("Average Yield strength- Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
600 |
|
- |
| 9/Table-4("Average Yield strength- Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 9/Table-4("Average Tensile Break strength- Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 9/Table-4("Average Tensile Break strength- Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 9/Table-4("Average Tensile yield Elongation %-Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 9/Table-4("Average Tensile yield Elongation %-Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 9/Table-4(Average Tensile Break Elongation %-Machine Direction, IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)) |
- |
0 |
|
- |
| 9/Table-4(Average Tensile Break Elongation -Transverse Direction, IS 13360 (Part 5/Sec 1) and S 13360 (Part 5/Sec 3)) |
- |
0 |
|
- |
| 9/Table-4(Average Tear resistance, IS 2508: 2024 Annex-D) |
- |
600 |
|
The test charges will be 3900/- for type IV |
| 5.1.1(Appearance) |
- |
0 |
|
- |
| 5.1.2(Film Form) |
- |
0 |
|
- |
| 5.1.3(Odour) |
- |
0 |
|
- |
| 5.1.5(Melt Flow Index- IS 13360 : Part 4 : Sec 1 : subsec 1 or IS 13360 : Part 4 : Sec 1 : subsec 2) |
- |
0 |
|
- |
| 5.2.1.1/ Table-1,2,3 &4(Nominal Thickness, Annex C,) |
- |
0 |
|
- |
| 5.2.1.2(Nominal Width) |
- |
0 |
|
- |
| 5.1.4 Sl No. (i) of Table 1, Table 2, Table 3 & Table 4.(Density - IS 13360 : Part 3 : Sec 10 : 2021) |
- |
0 |
|
- |
| 5.1.6(Black Film- Carbon black - IS 2508:2024) |
- |
0 |
|
- |
| 5.1.6(Ash content - IS 2508: 2024) |
- |
0 |
|
- |
| 5.1.6(carbon black dispersion - IS 2530: 1963) |
- |
0 |
|
- |
| 6, Type 1 (LDPE/LLDPE) /Table-1("Tensile strength at break-Machine direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| 6/Table-1("Tensile strength at break-Transverse direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| 6/Table-1("Elongation % at break, -Machine direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| 6/Table-1("Elongation % at break, -Transverse direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| 6/Table-1("Ageing test at (70 ± 1) ºC for 7 days-Machine Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 6/Table-1("Ageing test at (70 ± 1) ºC for 7 days- Transverse Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 6/Table-1(Dart impact strength,Method B of IS 13360 (Part 5/Sec 6)) |
- |
0 |
|
- |
| 6/Table-1(Tear resistance -Machine direction, IS 13360 (Part 5/Sec 23)) |
- |
0 |
|
- |
| 6/Table-1(Tear resistance-Transverse direction, IS 13360 (Part 5/Sec 23)) |
- |
0 |
|
- |
| " 7, Type 2 (HDPE/PE) /Table-2"("Tensile strength at break-Machine direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| " 7/Table-2"("Tensile strength at break-Transverse direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| " 7/Table-2"("Elongation % at break, -Machine direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| " 7/Table-2"("Elongation % at break, -Transverse direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
| " 7/Table-2"("Ageing test at (70 ± 1) ºC for 7 days-Machine Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| " 7/Table-2"("Ageing test at (70 ± 1) ºC for 7 days- Transverse Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| " 7/Table-2"(Dart impact strength,Method B of IS 13360 (Part 5/Sec 6)) |
- |
0 |
|
- |
| 8, Type 3 (LDPE/LLDPE, PE) /Table-3("Average Tensile Break strength- Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 8/Table-3("Average Tensile Break strength- Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 8/Table-3("Average Tensile Break Elongation %-Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 8/Table-3("Average Tensile Break Elongation %-Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 8/Table-3(Average Tear resistance, IS 2508: 2024 Annex-D) |
- |
0 |
|
- |
| 8/Table-3(Average Puncture resistance, IS 2508: 2024 Annex-E) |
- |
0 |
|
- |
| 9, Type 4 (HDPE/PE) /Table-4("Average Yield strength- Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 9/Table-4("Average Yield strength- Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 9/Table-4("Average Tensile Break strength- Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 9/Table-4("Average Tensile Break strength- Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 9/Table-4("Average Tensile yield Elongation %-Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 9/Table-4("Average Tensile yield Elongation %-Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
| 9/Table-4(Average Tensile Break Elongation %-Machine Direction, IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)) |
- |
0 |
|
- |
| 9/Table-4(Average Tensile Break Elongation -Transverse Direction, IS 13360 (Part 5/Sec 1) and S 13360 (Part 5/Sec 3)) |
- |
0 |
|
- |
| 9/Table-4(Average Tear resistance, IS 2508: 2024 Annex-D) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f.07.08.2025 |
| 3763 |
Classic Testing & Research Centre (B17), Noida
| 8180826
| IS 18112 (2025) |
DIGITAL TELEVISION RECEIVER FOR SATELLITE BROADCAST TRANSMISSION SPECIFICATION (First Revision) |
- |
125000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.4, Table-2, ii)(RF characteristics to be supported by the DTV receiver) |
- |
7000 |
|
- |
| Clause 4.3(Specifications) |
- |
7000 |
|
- |
| Clause 4.5(Safety Requirements) |
- |
7000 |
|
- |
| Clause 5(Marking) |
- |
7000 |
|
- |
| Clause 6(Operating Life Test) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, i) a)(Hardware specification) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, i) b)(Decompression and decoding of SDTV video) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, i) c)(Decompression and decoding of HDTV video) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, i) d)(Decompression and decoding of audio) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, i) e)(Active Format descriptors) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, i) f)(Captioning and Sub-titling) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, i) g)(Teletext) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, i) h)(Multi-language support) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, i) j)(DTV receiver mixed Audio Description) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, i) k)(Broadcast mixed audio description) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, i) m)(Service demultiplexing) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, i) n)(Data services) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, i) p)(OSD) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, i) q)(DTV character set) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, i) r)(Electronic Service Guide (ESG) ‘Now/Next’) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, i) s)(Time) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, i) t)(Digital TV output) |
- |
7000 |
|
- |
| Clause 4.4, Table-2, i) b)(Frequency) |
- |
7000 |
|
- |
| Clause 4.4, Table-2, i) a)(Input voltage range) |
- |
7000 |
|
- |
| Clause 4.1,Table-1, ii) a)(Demodulation and FEC decoding) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, ii) b)(DTV Receiver Installation) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, ii) c)(Network evolution) |
- |
7000 |
|
- |
| Clause 4.4, Table-2, iii) c)(RF input impedance) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, ii) d)(Services available) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, ii) e)(Selection via Service List) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, ii) f)(Selection via Numeric Entry) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, ii) g)(Favourite Channel list) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, ii) h)(Hidden Services) |
- |
7000 |
|
- |
| Clause 4.4, Table-2, iii) b)(Input frequency range) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, ii) j)(Logical Channel Number for Satellite services) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, ii) k)(RF input signal) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, ii) m)(LNB supply current) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, ii) n)(LNB supply voltage) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, ii) p)(LNB Control) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, ii) q)(Modulation/Demodulation parameters for DVB-S & DVB-S2 standard) |
- |
7000 |
|
- |
| Clause 4.4, Table-2, iii) a)(Input level per carrier) |
- |
7000 |
|
- |
| Clause 4.4, Table-2, iv) c)(RF input impedance) |
- |
7000 |
|
- |
| Clause 4.4, Table-2, iv) b)(Input frequency range) |
- |
7000 |
|
- |
| Clause 4.4, Table-2, iv) a)(Input level per carrier) |
- |
7000 |
|
- |
| Clause 4.4, Table-2, v)(Symbol rate) |
- |
7000 |
|
- |
| Clause 4.4, Table-2, vi)(RF input return loss) |
- |
7000 |
|
- |
| Clause 4.4, Table-2, vii)(DisEqC) |
- |
7000 |
|
- |
| Clause 4.4, Table-2, viii)(Operating ambient temperature range) |
- |
7000 |
|
- |
| Clause 4.4, Table-2, ix)(Operating humidity range) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, iii) a)(Interfaces, Connectors) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, iv)(Automatic software upgrade mechanism) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, v) a)(Remote Control) |
- |
7000 |
|
- |
| Clause 4.1, Table-1, v) b)(Easy to use and simple documentation) |
- |
7000 |
|
- |
| Clause 3.1, Table-1, v) c)(Support package) |
- |
7000 |
|
- |
|
15 Oct, 2027 |
- Included w.e.f.05.08.2025
Exclsuion
Clause 4.6 (Electromagnetic Compatibility (EMC) Requirements) |
| 3764 |
BIS, Guwahati Branch Laboratory (GBL)
| None
| IS 10079 (1982) |
Specification for cylindrical metal measures for use in tests of aggregates and concrete |
- |
2400.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1, Table 1 (Dimensions - Capacity) |
- |
|
|
|
| 4.1, Table 1 (Dimensions - Inside Diameter, A) |
- |
|
|
|
| 4.1, Table 1 (Dimensions - Thickness of metal (Min) - Wall, C) |
- |
|
|
|
| 4.1, Table 1 (Dimensions - Thickness of metal (Min) - Bottom, D) |
- |
|
|
|
| 5.1 (Construction) |
- |
|
|
|
| 6.1.1 (Accessories - Tamping Rod - Dia) |
- |
|
|
|
| 6.1.1 (Accessories - Tamping Rod - Length) |
- |
|
|
|
| 6.1.1 (Accessories - tamping rod) |
- |
|
|
|
| 6.2.1 (Accessories - Tamping Bar - tamping face (square)) |
- |
|
|
|
| 6.2.1 (Accessories - Tamping Bar - Length) |
- |
|
|
|
| 6.2.1 (Accessories - Tamping Bar - Weight) |
- |
|
|
|
| 6.2.1 (Accessories - Tamping Bar) |
- |
|
|
|
| 7.1 (Marking) |
- |
|
|
|
| 7.1 (Marking) |
- |
|
|
|
|
- |
- - |
| 3765 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 13487 (2024) |
Irrigation Equipment — Emitters — Specification |
All |
5287 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.1(Connections) |
- |
500 |
|
- |
| Cl-5.2(Emitter Ends) |
- |
200 |
|
- |
| Cl-5.3(Materials) |
- |
0 |
|
- |
| Cl-6.1(Test Specimens) |
- |
0 |
|
- |
| Cl-6.2.1(polyethylene pipe) |
- |
0 |
|
- |
| Cl-6.2.2("grease or chemicals
") |
- |
0 |
|
- |
| Cl-6.2.3(water temperature) |
- |
1000 |
|
- |
| Cl-6.3(Accuracy or Measuring Devices) |
- |
500 |
|
- |
| Cl-7.1(Construction and Workmanship) |
- |
500 |
|
- |
| Cl-7.2(Flow Paths in Emitter) |
- |
500 |
|
- |
| Cl-7.3(Resistance to Hydrostatic Pressure) |
- |
2000 |
|
- |
| Cl-7.4(Emitter Pull-Out) |
- |
1000 |
|
- |
| Cl-7.4.1(In-Line Emitters) |
- |
1000 |
|
- |
| Cl-7.4.2(On-Line Emitters) |
- |
1000 |
|
- |
| Cl-8.1.1(Uniformity of Emission Rate) |
- |
1000 |
|
- |
| Cl-8.1.2(Emission Rate as Function of Inlet Pressure) |
- |
1000 |
|
- |
| Cl-8.1.3(Determination of Emitter Exponent) |
- |
1000 |
|
- |
| Cl-9(Marking) |
- |
500 |
|
- |
| Cl-5.1(Connections) |
- |
500 |
|
- |
| Cl-5.2(Emitter Ends) |
- |
500 |
|
- |
| Cl-5.3(Materials) |
- |
500 |
|
- |
| Cl-6.1(Test Specimens) |
- |
0 |
|
- |
| Cl-6.2.1(polyethylene pipe) |
- |
0 |
|
- |
| Cl-6.2.2("grease or chemicals
") |
- |
0 |
|
- |
| Cl-6.2.3(water temperature) |
- |
1000 |
|
- |
| Cl-6.3(Accuracy or Measuring Devices) |
- |
500 |
|
- |
| Cl-7.1(Construction and Workmanship) |
- |
500 |
|
- |
| Cl-7.2(Flow Paths in Emitter) |
- |
500 |
|
- |
| Cl-7.3(Resistance to Hydrostatic Pressure) |
- |
2000 |
|
- |
| Cl-7.4(Emitter Pull-Out) |
- |
1000 |
|
- |
| Cl-7.4.1(In-Line Emitters) |
- |
1000 |
|
- |
| Cl-7.4.2(On-Line Emitters) |
- |
1000 |
|
- |
| Cl-8.1.1(Uniformity of Emission Rate) |
- |
1000 |
|
- |
| Cl-8.1.2(Emission Rate as Function of Inlet Pressure) |
- |
1000 |
|
- |
| Cl-8.1.3(Determination of Emitter Exponent) |
- |
1000 |
|
- |
| Cl-9(Marking) |
- |
500 |
|
- |
| Cl-5.1(Connections) |
- |
0 |
|
- |
| Cl-5.2(Emitter Ends) |
- |
0 |
|
- |
| Cl-5.3(Materials) |
- |
0 |
|
- |
| Cl-6.1(Test Specimens) |
- |
0 |
|
- |
| Cl-6.2.1(polyethylene pipe) |
- |
0 |
|
- |
| Cl-6.2.2("grease or chemicals
") |
- |
0 |
|
- |
| Cl-6.2.3(water temperature) |
- |
0 |
|
- |
| Cl-6.3(Accuracy or Measuring Devices) |
- |
0 |
|
- |
| Cl-7.1(Construction and Workmanship) |
- |
0 |
|
- |
| Cl-7.2(Flow Paths in Emitter) |
- |
0 |
|
- |
| Cl-7.3(Resistance to Hydrostatic Pressure) |
- |
0 |
|
- |
| Cl-7.4(Emitter Pull-Out) |
- |
0 |
|
- |
| Cl-7.4.1(In-Line Emitters) |
- |
0 |
|
- |
| Cl-7.4.2(On-Line Emitters) |
- |
0 |
|
- |
| Cl-8.1.1(Uniformity of Emission Rate) |
- |
0 |
|
- |
| Cl-8.1.2(Emission Rate as Function of Inlet Pressure) |
- |
0 |
|
- |
| Cl-8.1.3(Determination of Emitter Exponent) |
- |
0 |
|
- |
| Cl-9(Marking) |
- |
0 |
|
- |
| Cl-5.1(Connections) |
- |
0 |
|
- |
| Cl-5.2(Emitter Ends) |
- |
0 |
|
- |
| Cl-5.3(Materials) |
- |
0 |
|
- |
| Cl-6.1(Test Specimens) |
- |
0 |
|
- |
| Cl-6.2.1(polyethylene pipe) |
- |
0 |
|
- |
| Cl-6.2.2("grease or chemicals
") |
- |
0 |
|
- |
| Cl-6.2.3(water temperature) |
- |
0 |
|
- |
| Cl-6.3(Accuracy or Measuring Devices) |
- |
0 |
|
- |
| Cl-7.1(Construction and Workmanship) |
- |
0 |
|
- |
| Cl-7.2(Flow Paths in Emitter) |
- |
0 |
|
- |
| Cl-7.3(Resistance to Hydrostatic Pressure) |
- |
0 |
|
- |
| Cl-7.4(Emitter Pull-Out) |
- |
0 |
|
- |
| Cl-7.4.1(In-Line Emitters) |
- |
0 |
|
- |
| Cl-7.4.2(On-Line Emitters) |
- |
0 |
|
- |
| Cl-8.1.1(Uniformity of Emission Rate) |
- |
0 |
|
- |
| Cl-8.1.2(Emission Rate as Function of Inlet Pressure) |
- |
0 |
|
- |
| Cl-8.1.3(Determination of Emitter Exponent) |
- |
0 |
|
- |
| Cl-9(Marking) |
- |
0 |
|
- |
| Cl-5.1(Connections) |
- |
- |
|
- |
| Cl-5.2(Emitter Ends) |
- |
- |
|
- |
| Cl-5.3(Materials) |
- |
- |
|
- |
| Cl-6.1(Test Specimens) |
- |
- |
|
- |
| Cl-6.2.1(polyethylene pipe) |
- |
- |
|
- |
| Cl-6.2.2("grease or chemicals
") |
- |
- |
|
- |
| Cl-6.2.3(water temperature) |
- |
- |
|
- |
| Cl-6.3(Accuracy or Measuring Devices) |
- |
- |
|
- |
| Cl-7.1(Construction and Workmanship) |
- |
- |
|
- |
| Cl-7.2(Flow Paths in Emitter) |
- |
- |
|
- |
| Cl-7.3(Resistance to Hydrostatic Pressure) |
- |
- |
|
- |
| Cl-7.4(Emitter Pull-Out) |
- |
- |
|
- |
| Cl-7.4.1(In-Line Emitters) |
- |
- |
|
- |
| Cl-7.4.2(On-Line Emitters) |
- |
- |
|
- |
| Cl-8.1.1(Uniformity of Emission Rate) |
- |
- |
|
- |
| Cl-8.1.2(Emission Rate as Function of Inlet Pressure) |
- |
- |
|
- |
| Cl-8.1.3(Determination of Emitter Exponent) |
- |
- |
|
- |
| Cl-9(Marking) |
- |
- |
|
- |
|
10 Mar, 2027 |
- included w.e.f 11-12-2025. |
| 3766 |
GIGA LABS, BENGALURU
| 6177526
| IS/IEC 61439 : Part 2 (2020) |
Low-voltage switchgear and controlgear assemblies Part 2: Power switchgear and controlgear assemblies (First Revision) |
Low-voltage switchgear and controlgear assemblies Part 2: Power switchgear and controlgear assemblies |
795000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5(Interface characteristics) |
- |
10000 |
|
- |
| Cl-5.4(Rated diversity factor (RDF)) |
- |
10000 |
|
- |
| Cl-6(Information) |
- |
10000 |
|
- |
| Cl-7(Service conditions) |
- |
10000 |
|
- |
| Cl-8(Constructional requirements) |
- |
10000 |
|
- |
| Cl-8.1.1(Constructional requirements- General) |
- |
10000 |
|
- |
| Cl-8.2.1(Protection against mechanical impact (IK code) |
- |
20000 |
|
- |
| Cl-8.2.101(PSC-assembly with withdrawable parts) |
- |
20000 |
|
- |
| Cl-8.3.2(Clearances) |
- |
25000 |
|
- |
| Cl-8.4.3.2.2("Requirements for earth continuity providing protection against the
consequences of faults within the class I PSC-assembly") |
- |
15000 |
|
- |
| Cl-8.4.6.2.1(Requirements related to accessibility in service by authorized persons- General) |
- |
10000 |
|
- |
| Cl-8.4.6.2.101(Operating and maintenance gangways within a PSC-assembly) |
- |
10000 |
|
- |
| Cl-8.5.2(Removable and withdrawable parts) |
- |
10000 |
|
- |
| Cl-8.5.2.101(Withdrawable parts) |
- |
10000 |
|
- |
| Cl-8.5.2.102(Interlocking and padlocking of removable and withdrawable parts) |
- |
15000 |
|
- |
| Cl-8.5.3(Selection of switching devices and components) |
- |
15000 |
|
- |
| Cl-8.5.101(Description of the types of electrical connections of functional units) |
- |
10000 |
|
- |
| Cl-8.101(Internal separation of PSC-assemblies) |
- |
20000 |
|
- |
| Cl-9(Performance requirements) |
- |
25000 |
|
- |
| Cl-9.3.1(Performance requirements- General) |
- |
120000 |
|
- |
| Cl-10(Design verification) |
- |
10000 |
|
- |
| Cl-10.2.6(Verification of protection against mechanical impact (IK code)) |
- |
20000 |
|
- |
| Cl-10.2.8(Design verification- Mechanical operation) |
- |
20000 |
|
- |
| Cl-10.3(Degree of protection of PSC-assemblies (IP Code)) |
- |
40000 |
|
- |
| Cl-10.9.3.2(Impulse withstand voltage test) |
- |
25000 |
|
- |
| Cl-10.10(Temperature-rise) |
- |
150000 |
|
- |
| Cl-10.10.4.102(Assembly with active cooling and a rated current not exceeding 1 600 A) |
- |
25000 |
|
- |
| Cl-11(Routine verification) |
- |
100000 |
|
- |
| Cl-11.8(Routine verification- Mechanical operation) |
- |
20000 |
|
- |
|
08 Apr, 2027 |
- Included w.e.f 09.09.2025 |
| 3767 |
Robust Testing Solutions Private Limited, Alwar
| 8173526
| IS 398 : Part 2 (2025) |
Aluminium Conductor for Overhead Transmission Purposes - Specification Part 2 Aluminium Conductors Galvanized Steel Reinforced (Fourth Revision) |
- |
18000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-6(Material) |
- |
1000 |
|
Type test: Rs. 18000/- (upto 100 sq. mm), Rs. 100000/- (150 sqmm to 200 sq. mm), Rs. 150000/-(400sqmm to 560 sq mm) |
| Cl-7(Freedom From Defects) |
- |
1000 |
|
Type test: Rs. 18000/- (upto 100 sq. mm), Rs. 100000/- (150 sqmm to 200 sq. mm), Rs. 150000/-(400sqmm to 560 sq mm) |
| Cl-8.1(Wires-Nominal Sizes) |
- |
1000 |
|
Type test: Rs. 18000/- (upto 100 sq. mm), Rs. 100000/- (150 sqmm to 200 sq. mm), Rs. 150000/-(400sqmm to 560 sq mm) |
| Cl-8.2(Aluminum Conductors, Galvanized Steel- Reinforced) |
- |
1000 |
|
- |
| Cl-9.1(Joint in Wires) |
- |
0 |
|
- |
| Cl-9.2(Aluminium Wires) |
- |
0 |
|
- |
| Cl-9.3(Galvanized Steel Wires) |
- |
0 |
|
- |
| Cl-10.2(Lay Ratio of Aluminium Conductors Galvanized Steel-Reinforced) |
- |
5000 |
|
- |
| Cl-13.3(Conductor- Visual examination) |
- |
1000 |
|
- |
| Cl- 13.5(Conductor- Measurement of lay ratio/direction of lay) |
- |
5000 |
|
- |
| Cl- 13.12(Conductor- d.c. Resistance test on stranded conductor) |
- |
5000 |
|
- |
| Cl- 13.14(Conductor- Ultimate tensile strength test on stranded conductor) |
- |
10000 |
|
- |
| Cl- 13.13(Conductor- Surface condition test on stranded conductor) |
- |
10000 |
|
- |
| Cl-13.4(Aluminium wires-Measurement of diameter) |
- |
2000 |
|
- |
| Cl- 13.6(Aluminium wires -Breaking load test) |
- |
5000 |
|
- |
| Cl- 13.8(Aluminium wires- Wrapping test) |
- |
2500 |
|
- |
| Cl- 13.9(Aluminium wires- d.c. resistance test) |
- |
5000 |
|
- |
| Cl- 13.11(Aluminium wires Procedure qualification test on welded joint of aluminium strands) |
- |
0 |
|
- |
| Cl- 13.4(Steel wires- Measurement of diameter) |
- |
2000 |
|
- |
| Cl- 13.6(Steel wires- Breaking load test) |
- |
2000 |
|
- |
| Cl- 13.7(Steel wires- Ductility test) |
- |
2000 |
|
- |
| Cl- 13.8(Steel wires- Wrapping test) |
- |
2000 |
|
- |
| Cl- 13.10(Steel wires- Galvanizing test) |
- |
2500 |
|
- |
| Cl-13.7.1(Torsion Test) |
- |
2500 |
|
- |
| Cl-13.7.2(Elongation Test) |
- |
2500 |
|
- |
| Cl-11.1(Standard Length) |
- |
1000 |
|
- |
| Cl-11.2(Random Lengths) |
- |
0 |
|
- |
| Cl-6.2(zinc used for galvanizing) |
- |
0 |
|
- |
| Cl-6.1.1(chemical composition of high carbon steel) |
- |
0 |
|
- |
| Cl-6(Material) |
- |
0 |
|
- |
| Cl-7(Freedom From Defects) |
- |
1000 |
|
- |
| Cl-8.1(Wires-Nominal Sizes) |
- |
1000 |
|
- |
| Cl-8.2(Aluminum Conductors, Galvanized Steel- Reinforced) |
- |
0 |
|
- |
| Cl-9.1(Joint in Wires) |
- |
5000 |
|
- |
| Cl-9.2(Aluminium Wires) |
- |
0 |
|
- |
| Cl-9.3(Galvanized Steel Wires) |
- |
1000 |
|
- |
| Cl-10.2(Lay Ratio of Aluminium Conductors Galvanized Steel-Reinforced) |
- |
2000 |
|
- |
| Cl-13.3(Conductor- Visual examination) |
- |
2000 |
|
- |
| Cl- 13.5(Conductor- Measurement of lay ratio/direction of lay) |
- |
2000 |
|
- |
| Cl- 13.12(Conductor- d.c. Resistance test on stranded conductor) |
- |
5000 |
|
- |
| Cl- 13.14(Conductor- Ultimate tensile strength test on stranded conductor) |
- |
15000 |
|
- |
| Cl- 13.13(Conductor- Surface condition test on stranded conductor) |
- |
10000 |
|
- |
| Cl-13.4(Aluminium wires-Measurement of diameter) |
- |
10000 |
|
- |
| Cl- 13.6(Aluminium wires -Breaking load test) |
- |
10000 |
|
- |
| Cl- 13.8(Aluminium wires- Wrapping test) |
- |
10000 |
|
- |
| Cl- 13.9(Aluminium wires- d.c. resistance test) |
- |
10000 |
|
- |
| Cl- 13.11(Aluminium wires Procedure qualification test on welded joint of aluminium strands) |
- |
0 |
|
- |
| Cl- 13.4(Steel wires- Measurement of diameter) |
- |
2000 |
|
- |
| Cl- 13.6(Steel wires- Breaking load test) |
- |
5000 |
|
- |
| Cl- 13.7(Steel wires- Ductility test) |
- |
2000 |
|
- |
| Cl- 13.8(Steel wires- Wrapping test) |
- |
2000 |
|
- |
| Cl- 13.10(Steel wires- Galvanizing test) |
- |
2000 |
|
- |
| Cl-13.7.1(Torsion Test) |
- |
5000 |
|
- |
| Cl-13.7.2(Elongation Test) |
- |
5000 |
|
- |
| Cl-11.1(Standard Length) |
- |
0 |
|
- |
| Cl-11.2(Random Lengths) |
- |
0 |
|
- |
| Cl-6.1.1(chemical composition of high carbon steel) |
- |
0 |
|
- |
| Cl-6.2(zinc used for galvanizing) |
- |
5000 |
|
- |
| Cl-6(Material) |
- |
5000 |
|
- |
| Cl-7(Freedom From Defects) |
- |
5000 |
|
- |
| Cl-8.1(Wires-Nominal Sizes) |
- |
1000 |
|
- |
| Cl-8.2(Aluminum Conductors, Galvanized Steel- Reinforced) |
- |
1000 |
|
- |
| Cl-9.1(Joint in Wires) |
- |
1500 |
|
- |
| Cl-9.2(Aluminium Wires) |
- |
1500 |
|
- |
| Cl-9.3(Galvanized Steel Wires) |
- |
1500 |
|
- |
| Cl-10.2(Lay Ratio of Aluminium Conductors Galvanized Steel-Reinforced) |
- |
1500 |
|
- |
| Cl-13.3(Conductor- Visual examination) |
- |
1500 |
|
- |
| Cl- 13.5(Conductor- Measurement of lay ratio/direction of lay) |
- |
2000 |
|
- |
| Cl- 13.12(Conductor- d.c. Resistance test on stranded conductor) |
- |
2000 |
|
- |
| Cl- 13.14(Conductor- Ultimate tensile strength test on stranded conductor) |
- |
5000 |
|
- |
| Cl- 13.13(Conductor- Surface condition test on stranded conductor) |
- |
5000 |
|
- |
| Cl-13.4(Aluminium wires-Measurement of diameter) |
- |
1500 |
|
- |
| Cl- 13.6(Aluminium wires -Breaking load test) |
- |
1500 |
|
- |
| Cl- 13.8(Aluminium wires- Wrapping test) |
- |
3500 |
|
- |
| Cl- 13.9(Aluminium wires- d.c. resistance test) |
- |
4000 |
|
- |
| Cl- 13.11(Aluminium wires Procedure qualification test on welded joint of aluminium strands) |
- |
5000 |
|
- |
| Cl- 13.4(Steel wires- Measurement of diameter) |
- |
5000 |
|
- |
| Cl- 13.6(Steel wires- Breaking load test) |
- |
10000 |
|
- |
| Cl- 13.7(Steel wires- Ductility test) |
- |
5000 |
|
- |
| Cl- 13.8(Steel wires- Wrapping test) |
- |
5000 |
|
- |
| Cl- 13.10(Steel wires- Galvanizing test) |
- |
4500 |
|
- |
| Cl-13.7.1(Torsion Test) |
- |
4000 |
|
- |
| Cl-13.7.2(Elongation Test) |
- |
4000 |
|
- |
| Cl-11.1(Standard Length) |
- |
1500 |
|
- |
| Cl-11.2(Random Lengths) |
- |
4500 |
|
- |
| Cl-6.1.1(chemical composition of high carbon steel) |
- |
4000 |
|
- |
| Cl-6.2(zinc used for galvanizing) |
- |
4000 |
|
- |
|
02 Aug, 2029 |
- Included w.e.f 18.08.2025
Exclusion: Cl- 13.15 (Conductor- Corona test (for conductors intended for use at 400 kV and above voltage level for a.c. and ± 320 kV and above voltage level for d.c.))
Cl-13.16 (Conductor- Radio interference voltage test) |
| 3768 |
Bharat Test House Pvt. Ltd. 1668 Sonipat
| 9168306
| IS 18755 (2024) |
Tri-ply SS-AL-SS material used for manufacture of utensils and kitchen appliances Specification |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(Supply of material and designation) |
- |
0 |
|
- |
| Cl-5(Manufacturer) |
- |
0 |
|
- |
| Cl-6(Aluminium for use as matrix) |
- |
400 |
|
- |
| Cl-6(Top-surface of the aluminium matrix) |
- |
400 |
|
- |
| Cl-6(Bottom-surface of the aluminium matrix) |
- |
400 |
|
- |
| Cl-7.1.1(Tensile properties) |
- |
2000 |
|
- |
| Cl-7.1.1(Apparent Yield Strength) |
- |
2000 |
|
- |
| Cl-7.1.1(Tensile Strength Mpa,) |
- |
2000 |
|
- |
| Cl-7.1.2(Test Specimen) |
- |
0 |
|
- |
| Cl-7.1.3(Test Parameters) |
- |
0 |
|
- |
| Cl-7.2.1(Bond strength of Tri-Ply) |
- |
3000 |
|
- |
| Cl-7.2.2(Sample Preparation and Test Specimen) |
- |
0 |
|
- |
| Cl-7.2.3(Test Apparatus) |
- |
0 |
|
- |
| Cl-7.2.4(Procedure) |
- |
0 |
|
- |
| Cl-8.1(Sample of suitable size) |
- |
0 |
|
- |
| Cl-8.2(specimen for peel strength) |
- |
3000 |
|
- |
| Cl-8.3, table-3(T-Peel Strength, N/mm, Min SS304 and Al 19500 interface) |
- |
3000 |
|
- |
| Cl-8.3, table-3(T-Peel Strength, N/mm, Min SS430 and Al 19500 interface) |
- |
3000 |
|
- |
| Cl-9.1(Thickness) |
- |
1500 |
|
- |
| Cl-9.2(Diameter) |
- |
1500 |
|
- |
| Cl-9.3(Flatness) |
- |
1500 |
|
- |
| Cl-10(surface finish) |
- |
1000 |
|
- |
| Cl-11(Workmanship, finish and appearance) |
- |
1000 |
|
- |
| Cl-14(Marking) |
- |
500 |
|
- |
|
- |
- Included w.e.f 04.11.2025 |
| 3769 |
EMC Testing and Compliance LLP, Gurugram
| 8141526
| IS 302 : Part 1 (2024) |
Household and Similar Electrical Appliances â Safety Part 1 General Requirements (Seventh Revision) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 12(Charging of metal-ion batteries) |
- |
2000 |
|
- |
| 6(Classification- IS 302-1) |
- |
2000 |
|
- |
| 5(General conditions for the tests) |
- |
2000 |
|
- |
| 11.8(Temperature rise) |
- |
2000 |
|
- |
| 11.7(Duration corresponding) |
- |
2000 |
|
- |
| 11.6(Combined appliances) |
- |
2000 |
|
- |
| 11.5(Motor-operated appliances) |
- |
2000 |
|
- |
| 11.4(Heating appliances) |
- |
2000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
2000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
2000 |
|
- |
| 16(Leakage current and electric strength) |
- |
2000 |
|
- |
| 4(General requirement) |
- |
2000 |
|
- |
| 31(Resistance to Rusting) |
- |
2000 |
|
- |
| 30.2(Needle Flame Test) |
- |
2000 |
|
- |
| 30.2(Glow Wire Test) |
- |
2000 |
|
- |
| 30.1(Ball pressure test) |
- |
2000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
2000 |
|
- |
| 28(Screw test and connections) |
- |
2000 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
2000 |
|
- |
| 26(Terminals for external conductors) |
- |
2000 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
2000 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
2000 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
2000 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
2000 |
|
- |
| 19(Abnormal Operation) |
- |
2000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
2000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
2000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
2000 |
|
- |
| 16.1(General) |
- |
2000 |
|
- |
| 16.0(General) |
- |
2000 |
|
- |
| 15.3(Humidity Test) |
- |
2000 |
|
- |
| 15.2(Spillage Test) |
- |
2000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
2000 |
|
- |
| 14(Transient Over Voltages) |
- |
2000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
2000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
2000 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
2000 |
|
- |
| 11.3(Heating) |
- |
2000 |
|
- |
| 11.2(General) |
- |
2000 |
|
- |
| 11.1(General) |
- |
2000 |
|
- |
| 10.2(Current input) |
- |
2000 |
|
- |
| 10.1(Power input) |
- |
2000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
2000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
2000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
2000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
2000 |
|
- |
| 7(Marking and instructions) |
- |
2000 |
|
- |
| A.2(Earth continuity test) |
- |
2000 |
|
- |
| 15.2(Moisture resistance) |
- |
3000 |
|
- |
| 19.17(Abnormal Operation, IS 302-1) |
- |
2000 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
2000 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
2000 |
|
- |
| 21.3(Mechanical Strength, IS 302-1) |
- |
2000 |
|
- |
| 22.5(Construction) |
- |
2000 |
|
- |
| 22.6(Construction, IS 302-1) |
- |
2000 |
|
- |
| 22.11(Construction, IS 302-1) |
- |
2000 |
|
- |
| 22.16(Construction) |
- |
2000 |
|
- |
| 22.32(Construction, IS 302-1) |
- |
2000 |
|
- |
| 22.42(Construction) |
- |
2000 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
2000 |
|
- |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
2000 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 26.5(Terminals for external conductors) |
- |
2000 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
2000 |
|
- |
| 28.1(Screws and connections) |
- |
2000 |
|
- |
| 22.2(Construction, IS 302-1) |
- |
2000 |
|
- |
| 22.3(Construction, IS 302-1) |
- |
2000 |
|
- |
| B.22.4(Construction, IS 302-1) |
- |
2000 |
|
- |
| B.22.5(Construction, IS 302-1) |
- |
2000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
| 24(Components) |
- |
2000 |
|
- |
| 32.1(Radiation Toxicity and Similar Hazards) |
- |
2000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 15.0(Moisture resistance) |
- |
3000 |
|
- |
| Annex C(Ageing test on motors) |
- |
2000 |
|
- |
| Annex D(Thermal motor protectors) |
- |
2000 |
|
- |
|
19 Jul, 2027 |
- Included w.e.f 25.03.2025
Exclusion: Cl 19.11.4.1 to Cl 19.11.4.7 (EMI/EMC)
"Domestic Electric Clothes Washing Machines
(For testing charges please refer part 2 standard in LIMS)" |
| 3770 |
PAAM Testing Labs Private Limited, Greater Noida
| 8185506
| IS 903 (2025) |
Fire Hose Delivery Couplings, Branch Pipe, Nozzles and Nozzle Spanner - Specification (Fifth Revision) |
- |
42500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| As per Clause 5.2, 6.2, 7.2, 10.2(Dimensions & Tolerances) |
- |
17500 |
|
Separately for Cl. No. 5.2 as per Fig. 2A & 2B - 5500.00 / For Cl. No. 6.2 as per Fig. 3 - 4000.00 / For Cl. No. 7.2 as per Fig. 4 - 4000.00 / For Cl. No. 10.2 as per Fig. 5 - 4000.00. |
| As per Clause 9.1(Hydraulic test) |
- |
17600 |
|
Separately for Delivery Coupling (Cl. No. 5.4) - 6000.00 / For Branch Pipe (Cl. No. 6.4) - 5800.00 / and For Nozzles (Cl. No. 7.4) - 5800.00. |
| As per Clause 10.4(Deflection test requirement) |
- |
3800 |
|
- |
| Cl. 10.4(Deflection test requirement) |
- |
0 |
|
- |
| Cl. 4(WORKMANSHIP AND FINISH) |
- |
1600 |
|
Separately for Delivery Coupling - 400.00 / For Branch Pipe - 400.00 / For Nozzles - 400.00 / and For Nozzle Spanner - 400.00. |
| Cl. 5("INSTANTANEOUS DELIVERY HOSE
COUPLINGS") |
- |
0 |
|
- |
| Cl. 5.1(Design) |
- |
200 |
|
- |
| Cl. 5.3(Materials) |
- |
15000 |
|
Rs. 42500/- for complete testing excluding Material Test (Cl.5.3, 6.3, 7.3 & 8.0). |
| Cl. 5.4(Testing) |
- |
0 |
|
- |
| Cl. 6(BRANCH PIPE) |
- |
0 |
|
- |
| Cl. 6.3(Materials) |
- |
0 |
|
- |
| Cl. 6.4(Testing) |
- |
0 |
|
- |
| Cl. 7(NOZZLES) |
- |
0 |
|
- |
| Cl. 7.3(Materials) |
- |
0 |
|
- |
| Cl. 7.4(Testing) |
- |
0 |
|
- |
| Cl. 8(Materials) |
- |
0 |
|
- |
| Cl. 9.1(PERFORMANCE TEST) |
- |
0 |
|
- |
| Cl. 9.1(Hydraulic Test) |
- |
0 |
|
- |
| Cl. 10(NOZZLE SPANNER) |
- |
0 |
|
- |
| Cl. 11(MARKING) |
- |
720 |
|
Separately for Delivery Coupling - 180.00 / For Branch Pipe - 180.00 / For Nozzles - 180.00 / and For Nozzle Spanner - 180.00. |
| Cl-4(Workmanship and Finish) |
- |
0 |
|
- |
| Cl-5.4(DELIVERY HOSE COUPLINGS- Hydraulic test) |
- |
0 |
|
- |
| Cl-6.1(BRANCH PIPE -Design) |
- |
200 |
|
- |
| Cl-6.4(BRANCH PIPE -Hydraulic test) |
- |
0 |
|
- |
| Cl-7.1(NOZZLES -Design) |
- |
200 |
|
- |
| Cl-7.4(NOZZLES -Hydraulic test) |
- |
0 |
|
- |
| Cl-10.1(NOZZLE SPANNER - Material) |
- |
0 |
|
- |
| Cl-10.3(NOZZLE SPANNER - Anti-corrosive treatment) |
- |
0 |
|
- |
|
08 May, 2028 |
- Included w.e.f 23.07.2025 |
| 3771 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 5950 (2024) |
Shot Firing Cables (for Use Other than in Shafts) - Specification (Second Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Section-3, Cl-6 (CONDUCTOR) |
- |
|
|
|
| Section-3, Cl-7.2 (Tolerance on Thickness of Insulation) |
- |
|
|
|
| Section-3, Cl-7.3 (Colour of Insulation) |
- |
|
|
|
| Section-3, Cl-8.1 (Single-Core) |
- |
|
|
|
| Section-3, Cl-8.2 (Tolerance on Thickness of Sheath) |
- |
|
|
|
| Section-3, Cl-8.3 (Color of Sheath) |
- |
|
|
|
| Cl-10.2 (Voltage Test) |
- |
|
|
|
| Cl-10.4 (Flammability Test) |
- |
|
|
|
| Cl-9.1 (a) (Annealing test;) |
- |
|
|
|
| Cl-9.1 (b) (Conductor resistance test) |
- |
|
|
|
| Cl-9.1 (c) (Test for thickness of insulation and sheath) |
- |
|
|
|
| Cl-9.1 (d) 1 (Tensile strength and elongation at break) |
- |
|
|
|
| Cl-9.1 (d) 2 (Ageing in air oven) |
- |
|
|
|
| Cl-9.1 (d) 3 (Loss of mass test) |
- |
|
|
|
| Cl-9.1 (d) 4 (Hot deformation) |
- |
|
|
|
| Cl-9.1 (d) 5 (Heat shock) |
- |
|
|
|
| Cl-9.1 (d) 6 (hrinkage) |
- |
|
|
|
| Cl-9.2 , e (Insulation resistance test) |
- |
|
|
|
|
- |
- Complete |
| 3772 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 5290 (2025) |
Landing Valves - Specification (Fourth Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-6 (FINISH) |
- |
|
|
|
| Cl-4.3, Table-1 (Flanged -Outer Diameter) |
- |
|
|
|
| Cl-4.3, Table-1 (Flanged - Thickness) |
- |
|
|
|
| Cl-4.3, Table-1 (Flanged -Pitch Circle Diameter (PCD)) |
- |
|
|
|
| Cl-4.3, Table-1 (Flanged -No. of Holes × Diameter of Hole) |
- |
|
|
|
| Cl-4.3, Table-1 (Threaded) |
- |
|
|
|
| Cl-4.2 (shape and dimensions of) |
- |
|
|
|
| Cl-4.4 (Outlet(s) of landing valve) |
- |
|
|
|
| Cl-4.4 (dimensions- outlet adaptor) |
- |
|
|
|
| Cl-4.4 (dimensions- Blank cap for outlet) |
- |
|
|
|
| Table 1 of IS 617 (Al) |
- |
|
|
|
| Cl 3.1 (Cu) |
- |
|
|
|
| Table 1 ,(Cl. 4, 8.1, 8.3 ,8.4.1 (SS) |
- |
|
|
|
|
- |
- Facility not available for performance test, Al, Ti |
| 3773 |
Akshat Test Lab & Calibration Services, Ghaziabad
| 8186526
| IS 4159 (2021) |
Mineral Filled Sheathed Heating Elements |
Mineral Filled Sheathed Heating Elements |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| "Cl. 6 IS 4159:2021"(Classification) |
- |
500 |
|
- |
| "Cl. 8 IS 4159:2021"(Protection against access to live parts) |
- |
800 |
|
- |
| "Cl. 9 IS 4159:2021"(Starting of motor operated appliances) |
- |
1000 |
|
- |
| "Cl. 10 IS 4159:2021"(Power Input and Current) |
- |
900 |
|
- |
| "Cl. 11 IS 4159:2021"(Heating) |
- |
1500 |
|
- |
| "Cl. 13 IS 4159:2021"(Leakage Current & Electrical Strength at Operating Temperature) |
- |
1000 |
|
- |
| "Cl. 14 IS 4159:2021"(Transient Over Voltage) |
- |
1500 |
|
- |
| "Cl. 15 IS 4159:2021"(Moisture Resistance) |
- |
1000 |
|
- |
| "Cl. 16 IS 4159:2021"(Leakage Current and Electric strength) |
- |
1000 |
|
- |
| "Cl. 17 IS 4159:2021"(Overload protection of transformers and associated circuits.) |
- |
1000 |
|
- |
| "Cl. 18 IS 4159:2021"(Endurance) |
- |
1500 |
|
- |
| "Cl. 19 IS 4159:2021"(Abnormal Operation) |
- |
1500 |
|
- |
| "Cl. 20 IS 4159:2021"(Stability and mechanical Hazards) |
- |
1000 |
|
- |
| "Cl. 21 IS 4159:2021"(Mechanical Strength) |
- |
1500 |
|
- |
| "Cl. 22 IS 4159:2021"(Construction) |
- |
1500 |
|
- |
| "Cl. 23 IS 4159:2021"(Internal Wiring) |
- |
500 |
|
- |
| "Cl. 24 IS 4159:2021"(Components) |
- |
500 |
|
- |
| "Cl. 25 IS 4159:2021"(Supply Connections and External Flexible Cables and Cords) |
- |
1500 |
|
- |
| "Cl. 26 IS 4159:2021"(Terminal For External Conductors) |
- |
1000 |
|
- |
| "Cl. 27 IS 4159:2021"(Provision For Earthing) |
- |
500 |
|
- |
| "Cl. 28 IS 4159:2021"(Screws and Connections) |
- |
500 |
|
- |
| "Cl. 29 IS 4159:2021"(Creepage Distances, Clearances And Distances Through Insulation) |
- |
500 |
|
- |
| "Cl. 30 IS 4159:2021"(Resistance To Heat, Fire And Tracking) |
- |
1000 |
|
- |
| "Cl. 31 IS 4159:2021"(Resistance To Rusting) |
- |
500 |
|
- |
| "Cl. 102 IS 4159:2021"(Leakage and hydrostatic strength (for oil heating elements)) |
- |
500 |
|
- |
| Cl.22.106(CONSTRUCTION) |
- |
1500 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
100 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
100 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
100 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
100 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
100 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
100 |
|
- |
| Cl.7.2 of IS 4159:2021(Marking) |
- |
100 |
|
- |
| Cl.7.3 of IS 4159:2021(Marking) |
- |
100 |
|
- |
| Cl.10 of IS 302-1:2008(Power Input & Current) |
- |
500 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
500 |
|
- |
| Cl.11.2 of IS 4159:2021(Heating) |
- |
500 |
|
- |
| Cl.11.101 of IS 4159:2021(Heating) |
- |
500 |
|
- |
| Cl.18 of IS 4159:2021(Endurance Test) |
- |
500 |
|
- |
| Cl.19.2 of IS 302-1: 2008(Abnormal Operation) |
- |
500 |
|
- |
| Cl.19.3 of IS 302-1: 2008(Abnormal Operation) |
- |
500 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
500 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
500 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
500 |
|
- |
| Cl.22.101 of IS 4159:2021(Construction) |
- |
500 |
|
- |
| Cl.22.102 of IS 4159:2021(Construction) |
- |
500 |
|
- |
| Cl.22.103 of IS 4159:2021(Construction) |
- |
500 |
|
- |
| Cl.22.104 of IS 4159:2021(Construction) |
- |
500 |
|
- |
| Cl.22.105 of IS 4159:2021(Construction) |
- |
500 |
|
- |
| Cl.22.106 of IS 4159:2021(Construction) |
- |
500 |
|
- |
| Cl.22.107 of IS 4159:2021(Construction) |
- |
500 |
|
- |
| Cl.22.108 of IS 4159:2021(Construction) |
- |
500 |
|
- |
| Cl.22.109 of IS 4159:2021(Construction) |
- |
500 |
|
- |
| Cl.22.110 of IS 4159:2021(Construction) |
- |
500 |
|
- |
| Cl.22.111 of IS 4159:2021(Construction) |
- |
500 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
500 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
0 |
|
- |
| Cl.28.1 & IS 302-1: 2008(Screws & Connection) |
- |
500 |
|
- |
| Cl.28.4 IS 302-1: 2008(Screws & Connection) |
- |
500 |
|
- |
| Cl. 29.1 & IS 302-1: 2008(Creepage Distances & Clearances) |
- |
500 |
|
- |
| Cl. 29.2 & IS 302-1: 2009(Creepage Distances & Clearances) |
- |
500 |
|
For BIS-1kv to 3 kv= 8800
Above 3kv =20000
For Others- 1 kv to 3 kv= 20000
Above 3 kv= 40000 |
| "Cl. 6 IS 4159:2021"(Classification) |
- |
0 |
|
- |
| "Cl. 8 IS 4159:2021"(Protection against access to live parts) |
- |
0 |
|
- |
| "Cl. 9 IS 4159:2021"(Starting of motor operated appliances) |
- |
0 |
|
- |
| "Cl. 10 IS 4159:2021"(Power Input and Current) |
- |
0 |
|
- |
| "Cl. 11 IS 4159:2021"(Heating) |
- |
0 |
|
- |
| "Cl. 13 IS 4159:2021"(Leakage Current & Electrical Strength at Operating Temperature) |
- |
0 |
|
- |
| "Cl. 14 IS 4159:2021"(Transient Over Voltage) |
- |
0 |
|
- |
| "Cl. 15 IS 4159:2021"(Moisture Resistance) |
- |
0 |
|
- |
| "Cl. 16 IS 4159:2021"(Leakage Current and Electric strength) |
- |
0 |
|
- |
| "Cl. 17 IS 4159:2021"(Overload protection of transformers and associated circuits.) |
- |
0 |
|
- |
| "Cl. 18 IS 4159:2021"(Endurance) |
- |
0 |
|
- |
| "Cl. 19 IS 4159:2021"(Abnormal Operation) |
- |
0 |
|
- |
| "Cl. 20 IS 4159:2021"(Stability and mechanical Hazards) |
- |
0 |
|
- |
| "Cl. 21 IS 4159:2021"(Mechanical Strength) |
- |
0 |
|
- |
| "Cl. 22 IS 4159:2021"(Construction) |
- |
0 |
|
- |
| "Cl. 23 IS 4159:2021"(Internal Wiring) |
- |
0 |
|
- |
| "Cl. 24 IS 4159:2021"(Components) |
- |
0 |
|
- |
| "Cl. 25 IS 4159:2021"(Supply Connections and External Flexible Cables and Cords) |
- |
0 |
|
- |
| "Cl. 26 IS 4159:2021"(Terminal For External Conductors) |
- |
0 |
|
- |
| "Cl. 27 IS 4159:2021"(Provision For Earthing) |
- |
0 |
|
- |
| "Cl. 28 IS 4159:2021"(Screws and Connections) |
- |
0 |
|
- |
| "Cl. 29 IS 4159:2021"(Creepage Distances, Clearances And Distances Through Insulation) |
- |
0 |
|
- |
| "Cl. 30 IS 4159:2021"(Resistance To Heat, Fire And Tracking) |
- |
0 |
|
- |
| "Cl. 31 IS 4159:2021"(Resistance To Rusting) |
- |
0 |
|
- |
| "Cl. 102 IS 4159:2021"(Leakage and hydrostatic strength (for oil heating elements)) |
- |
0 |
|
- |
| Cl.22.106(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.2 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.3 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.10 of IS 302-1:2008(Power Input & Current) |
- |
0 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
0 |
|
- |
| Cl.11.2 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.11.101 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.18 of IS 4159:2021(Endurance Test) |
- |
0 |
|
- |
| Cl.19.2 of IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.3 of IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.22.101 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.102 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.103 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.104 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.105 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.106 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.107 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.108 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.109 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.110 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.111 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
0 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
0 |
|
- |
| Cl.28.1 & IS 302-1: 2008(Screws & Connection) |
- |
0 |
|
- |
| Cl.28.4 IS 302-1: 2008(Screws & Connection) |
- |
0 |
|
- |
| Cl. 29.1 & IS 302-1: 2008(Creepage Distances & Clearances) |
- |
0 |
|
- |
| Cl. 29.2 & IS 302-1: 2009(Creepage Distances & Clearances) |
- |
0 |
|
For BIS-1kv to 3 kv= 8800
Above 3kv =20000
For Others- 1 kv to 3 kv= 20000
Above 3 kv= 40000 |
| "Cl. 6 IS 4159:2021"(Classification) |
- |
0 |
|
- |
| "Cl. 8 IS 4159:2021"(Protection against access to live parts) |
- |
0 |
|
- |
| "Cl. 9 IS 4159:2021"(Starting of motor operated appliances) |
- |
0 |
|
- |
| "Cl. 10 IS 4159:2021"(Power Input and Current) |
- |
0 |
|
- |
| "Cl. 11 IS 4159:2021"(Heating) |
- |
0 |
|
- |
| "Cl. 13 IS 4159:2021"(Leakage Current & Electrical Strength at Operating Temperature) |
- |
0 |
|
- |
| "Cl. 14 IS 4159:2021"(Transient Over Voltage) |
- |
0 |
|
- |
| "Cl. 15 IS 4159:2021"(Moisture Resistance) |
- |
0 |
|
- |
| "Cl. 16 IS 4159:2021"(Leakage Current and Electric strength) |
- |
0 |
|
- |
| "Cl. 17 IS 4159:2021"(Overload protection of transformers and associated circuits.) |
- |
0 |
|
- |
| "Cl. 18 IS 4159:2021"(Endurance) |
- |
0 |
|
- |
| "Cl. 19 IS 4159:2021"(Abnormal Operation) |
- |
0 |
|
- |
| "Cl. 20 IS 4159:2021"(Stability and mechanical Hazards) |
- |
0 |
|
- |
| "Cl. 21 IS 4159:2021"(Mechanical Strength) |
- |
0 |
|
- |
| "Cl. 22 IS 4159:2021"(Construction) |
- |
0 |
|
- |
| "Cl. 23 IS 4159:2021"(Internal Wiring) |
- |
0 |
|
- |
| "Cl. 24 IS 4159:2021"(Components) |
- |
0 |
|
- |
| "Cl. 25 IS 4159:2021"(Supply Connections and External Flexible Cables and Cords) |
- |
0 |
|
- |
| "Cl. 26 IS 4159:2021"(Terminal For External Conductors) |
- |
0 |
|
- |
| "Cl. 27 IS 4159:2021"(Provision For Earthing) |
- |
0 |
|
- |
| "Cl. 28 IS 4159:2021"(Screws and Connections) |
- |
0 |
|
- |
| "Cl. 29 IS 4159:2021"(Creepage Distances, Clearances And Distances Through Insulation) |
- |
0 |
|
- |
| "Cl. 30 IS 4159:2021"(Resistance To Heat, Fire And Tracking) |
- |
0 |
|
- |
| "Cl. 31 IS 4159:2021"(Resistance To Rusting) |
- |
0 |
|
- |
| "Cl. 102 IS 4159:2021"(Leakage and hydrostatic strength (for oil heating elements)) |
- |
0 |
|
- |
| Cl.22.106(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.2 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.3 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.10 of IS 302-1:2008(Power Input & Current) |
- |
0 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
0 |
|
- |
| Cl.11.2 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.11.101 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.18 of IS 4159:2021(Endurance Test) |
- |
0 |
|
- |
| Cl.19.2 of IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.3 of IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.22.101 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.102 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.103 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.104 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.105 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.106 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.107 of IS 4159:2021(Construction) |
- |
0 |
|
For BIS-1kv to 3 kv= 8800
Above 3kv =20000
For Others- 1 kv to 3 kv= 20000
Above 3 kv= 40000 |
| Cl.22.108 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.109 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.110 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.111 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
0 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
0 |
|
- |
| Cl.28.1 & IS 302-1: 2008(Screws & Connection) |
- |
0 |
|
- |
| Cl.28.4 IS 302-1: 2008(Screws & Connection) |
- |
0 |
|
- |
| Cl. 29.1 & IS 302-1: 2008(Creepage Distances & Clearances) |
- |
0 |
|
- |
| Cl. 29.2 & IS 302-1: 2009(Creepage Distances & Clearances) |
- |
0 |
|
- |
| "Cl. 6 IS 4159:2021"(Classification) |
- |
0 |
|
- |
| "Cl. 8 IS 4159:2021"(Protection against access to live parts) |
- |
0 |
|
- |
| "Cl. 9 IS 4159:2021"(Starting of motor operated appliances) |
- |
0 |
|
- |
| "Cl. 10 IS 4159:2021"(Power Input and Current) |
- |
0 |
|
- |
| "Cl. 11 IS 4159:2021"(Heating) |
- |
0 |
|
- |
| "Cl. 13 IS 4159:2021"(Leakage Current & Electrical Strength at Operating Temperature) |
- |
0 |
|
- |
| "Cl. 14 IS 4159:2021"(Transient Over Voltage) |
- |
0 |
|
- |
| "Cl. 15 IS 4159:2021"(Moisture Resistance) |
- |
0 |
|
- |
| "Cl. 16 IS 4159:2021"(Leakage Current and Electric strength) |
- |
0 |
|
- |
| "Cl. 17 IS 4159:2021"(Overload protection of transformers and associated circuits.) |
- |
0 |
|
- |
| "Cl. 18 IS 4159:2021"(Endurance) |
- |
0 |
|
- |
| "Cl. 19 IS 4159:2021"(Abnormal Operation) |
- |
0 |
|
- |
| "Cl. 20 IS 4159:2021"(Stability and mechanical Hazards) |
- |
0 |
|
- |
| "Cl. 21 IS 4159:2021"(Mechanical Strength) |
- |
0 |
|
- |
| "Cl. 22 IS 4159:2021"(Construction) |
- |
0 |
|
- |
| "Cl. 23 IS 4159:2021"(Internal Wiring) |
- |
0 |
|
- |
| "Cl. 24 IS 4159:2021"(Components) |
- |
0 |
|
- |
| "Cl. 25 IS 4159:2021"(Supply Connections and External Flexible Cables and Cords) |
- |
0 |
|
- |
| "Cl. 26 IS 4159:2021"(Terminal For External Conductors) |
- |
0 |
|
- |
| "Cl. 27 IS 4159:2021"(Provision For Earthing) |
- |
0 |
|
- |
| "Cl. 28 IS 4159:2021"(Screws and Connections) |
- |
0 |
|
- |
| "Cl. 29 IS 4159:2021"(Creepage Distances, Clearances And Distances Through Insulation) |
- |
0 |
|
- |
| "Cl. 30 IS 4159:2021"(Resistance To Heat, Fire And Tracking) |
- |
0 |
|
- |
| "Cl. 31 IS 4159:2021"(Resistance To Rusting) |
- |
0 |
|
- |
| "Cl. 102 IS 4159:2021"(Leakage and hydrostatic strength (for oil heating elements)) |
- |
0 |
|
- |
| Cl.22.106(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.2 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.3 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.10 of IS 302-1:2008(Power Input & Current) |
- |
0 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
0 |
|
- |
| Cl.11.2 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.11.101 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.18 of IS 4159:2021(Endurance Test) |
- |
0 |
|
- |
| Cl.19.2 of IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.3 of IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.22.101 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.102 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.103 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.104 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.105 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.106 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.107 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.108 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.109 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.110 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.111 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
0 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
0 |
|
- |
| Cl.28.1 & IS 302-1: 2008(Screws & Connection) |
- |
0 |
|
- |
| Cl.28.4 IS 302-1: 2008(Screws & Connection) |
- |
0 |
|
- |
| Cl. 29.1 & IS 302-1: 2008(Creepage Distances & Clearances) |
- |
0 |
|
- |
| Cl. 29.2 & IS 302-1: 2009(Creepage Distances & Clearances) |
- |
0 |
|
- |
| "Cl. 6 IS 4159:2021"(Classification) |
- |
0 |
|
- |
| "Cl. 8 IS 4159:2021"(Protection against access to live parts) |
- |
0 |
|
- |
| "Cl. 9 IS 4159:2021"(Starting of motor operated appliances) |
- |
0 |
|
- |
| "Cl. 10 IS 4159:2021"(Power Input and Current) |
- |
0 |
|
- |
| "Cl. 11 IS 4159:2021"(Heating) |
- |
0 |
|
- |
| "Cl. 13 IS 4159:2021"(Leakage Current & Electrical Strength at Operating Temperature) |
- |
0 |
|
- |
| "Cl. 14 IS 4159:2021"(Transient Over Voltage) |
- |
0 |
|
- |
| "Cl. 15 IS 4159:2021"(Moisture Resistance) |
- |
0 |
|
- |
| "Cl. 16 IS 4159:2021"(Leakage Current and Electric strength) |
- |
0 |
|
- |
| "Cl. 17 IS 4159:2021"(Overload protection of transformers and associated circuits.) |
- |
0 |
|
- |
| "Cl. 18 IS 4159:2021"(Endurance) |
- |
0 |
|
- |
| "Cl. 19 IS 4159:2021"(Abnormal Operation) |
- |
0 |
|
- |
| "Cl. 20 IS 4159:2021"(Stability and mechanical Hazards) |
- |
0 |
|
- |
| "Cl. 21 IS 4159:2021"(Mechanical Strength) |
- |
0 |
|
- |
| "Cl. 22 IS 4159:2021"(Construction) |
- |
0 |
|
- |
| "Cl. 23 IS 4159:2021"(Internal Wiring) |
- |
0 |
|
- |
| "Cl. 24 IS 4159:2021"(Components) |
- |
0 |
|
- |
| "Cl. 25 IS 4159:2021"(Supply Connections and External Flexible Cables and Cords) |
- |
0 |
|
- |
| "Cl. 26 IS 4159:2021"(Terminal For External Conductors) |
- |
0 |
|
- |
| "Cl. 27 IS 4159:2021"(Provision For Earthing) |
- |
0 |
|
- |
| "Cl. 28 IS 4159:2021"(Screws and Connections) |
- |
0 |
|
- |
| "Cl. 29 IS 4159:2021"(Creepage Distances, Clearances And Distances Through Insulation) |
- |
0 |
|
- |
| "Cl. 30 IS 4159:2021"(Resistance To Heat, Fire And Tracking) |
- |
0 |
|
- |
| "Cl. 31 IS 4159:2021"(Resistance To Rusting) |
- |
0 |
|
- |
| "Cl. 102 IS 4159:2021"(Leakage and hydrostatic strength (for oil heating elements)) |
- |
0 |
|
- |
| Cl.22.106(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.2 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.3 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.10 of IS 302-1:2008(Power Input & Current) |
- |
0 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
0 |
|
- |
| Cl.11.2 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.11.101 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.18 of IS 4159:2021(Endurance Test) |
- |
0 |
|
- |
| Cl.19.2 of IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.3 of IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.22.101 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.102 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.103 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.104 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.105 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.106 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.107 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| "Cl. 6 IS 4159:2021"(Classification) |
- |
0 |
|
- |
| "Cl. 8 IS 4159:2021"(Protection against access to live parts) |
- |
0 |
|
- |
| "Cl. 9 IS 4159:2021"(Starting of motor operated appliances) |
- |
0 |
|
- |
| "Cl. 10 IS 4159:2021"(Power Input and Current) |
- |
0 |
|
- |
| "Cl. 11 IS 4159:2021"(Heating) |
- |
0 |
|
- |
| "Cl. 13 IS 4159:2021"(Leakage Current & Electrical Strength at Operating Temperature) |
- |
0 |
|
- |
| "Cl. 14 IS 4159:2021"(Transient Over Voltage) |
- |
0 |
|
- |
| "Cl. 15 IS 4159:2021"(Moisture Resistance) |
- |
0 |
|
- |
| "Cl. 16 IS 4159:2021"(Leakage Current and Electric strength) |
- |
0 |
|
- |
| "Cl. 17 IS 4159:2021"(Overload protection of transformers and associated circuits.) |
- |
0 |
|
- |
| "Cl. 18 IS 4159:2021"(Endurance) |
- |
0 |
|
- |
| "Cl. 19 IS 4159:2021"(Abnormal Operation) |
- |
0 |
|
- |
| "Cl. 20 IS 4159:2021"(Stability and mechanical Hazards) |
- |
0 |
|
- |
| "Cl. 21 IS 4159:2021"(Mechanical Strength) |
- |
0 |
|
- |
| "Cl. 22 IS 4159:2021"(Construction) |
- |
0 |
|
- |
| "Cl. 23 IS 4159:2021"(Internal Wiring) |
- |
0 |
|
- |
| "Cl. 24 IS 4159:2021"(Components) |
- |
0 |
|
- |
| "Cl. 25 IS 4159:2021"(Supply Connections and External Flexible Cables and Cords) |
- |
0 |
|
- |
| "Cl. 26 IS 4159:2021"(Terminal For External Conductors) |
- |
0 |
|
- |
| "Cl. 27 IS 4159:2021"(Provision For Earthing) |
- |
0 |
|
- |
| "Cl. 28 IS 4159:2021"(Screws and Connections) |
- |
0 |
|
- |
| "Cl. 29 IS 4159:2021"(Creepage Distances, Clearances And Distances Through Insulation) |
- |
0 |
|
- |
| "Cl. 30 IS 4159:2021"(Resistance To Heat, Fire And Tracking) |
- |
0 |
|
- |
| "Cl. 31 IS 4159:2021"(Resistance To Rusting) |
- |
0 |
|
- |
| "Cl. 102 IS 4159:2021"(Leakage and hydrostatic strength (for oil heating elements)) |
- |
0 |
|
- |
| Cl.22.106(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.2 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.3 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.10 of IS 302-1:2008(Power Input & Current) |
- |
0 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
0 |
|
- |
| Cl.11.2 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.11.101 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.18 of IS 4159:2021(Endurance Test) |
- |
0 |
|
- |
| Cl.19.2 of IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.3 of IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.22.101 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.102 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.103 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.104 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.105 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.106 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.107 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.108 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.109 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.110 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.111 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
0 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
0 |
|
- |
| Cl.28.1 & IS 302-1: 2008(Screws & Connection) |
- |
0 |
|
- |
| Cl.28.4 IS 302-1: 2008(Screws & Connection) |
- |
0 |
|
- |
| Cl. 29.1 & IS 302-1: 2008(Creepage Distances & Clearances) |
- |
0 |
|
- |
| Cl. 29.2 & IS 302-1: 2009(Creepage Distances & Clearances) |
- |
0 |
|
- |
| "Cl. 6 IS 4159:2021"(Classification) |
- |
0 |
|
- |
| "Cl. 8 IS 4159:2021"(Protection against access to live parts) |
- |
0 |
|
- |
| "Cl. 9 IS 4159:2021"(Starting of motor operated appliances) |
- |
0 |
|
- |
| "Cl. 10 IS 4159:2021"(Power Input and Current) |
- |
0 |
|
- |
| "Cl. 11 IS 4159:2021"(Heating) |
- |
0 |
|
- |
| "Cl. 13 IS 4159:2021"(Leakage Current & Electrical Strength at Operating Temperature) |
- |
0 |
|
- |
| "Cl. 14 IS 4159:2021"(Transient Over Voltage) |
- |
0 |
|
- |
| "Cl. 15 IS 4159:2021"(Moisture Resistance) |
- |
0 |
|
- |
| "Cl. 16 IS 4159:2021"(Leakage Current and Electric strength) |
- |
0 |
|
- |
| "Cl. 17 IS 4159:2021"(Overload protection of transformers and associated circuits.) |
- |
0 |
|
- |
| "Cl. 18 IS 4159:2021"(Endurance) |
- |
0 |
|
- |
| "Cl. 19 IS 4159:2021"(Abnormal Operation) |
- |
0 |
|
- |
| "Cl. 20 IS 4159:2021"(Stability and mechanical Hazards) |
- |
0 |
|
- |
| "Cl. 21 IS 4159:2021"(Mechanical Strength) |
- |
0 |
|
- |
| "Cl. 22 IS 4159:2021"(Construction) |
- |
0 |
|
- |
| "Cl. 23 IS 4159:2021"(Internal Wiring) |
- |
0 |
|
- |
| "Cl. 24 IS 4159:2021"(Components) |
- |
0 |
|
- |
| "Cl. 25 IS 4159:2021"(Supply Connections and External Flexible Cables and Cords) |
- |
0 |
|
- |
| "Cl. 26 IS 4159:2021"(Terminal For External Conductors) |
- |
0 |
|
- |
| "Cl. 27 IS 4159:2021"(Provision For Earthing) |
- |
0 |
|
- |
| "Cl. 28 IS 4159:2021"(Screws and Connections) |
- |
0 |
|
- |
| "Cl. 29 IS 4159:2021"(Creepage Distances, Clearances And Distances Through Insulation) |
- |
0 |
|
- |
| "Cl. 30 IS 4159:2021"(Resistance To Heat, Fire And Tracking) |
- |
0 |
|
- |
| "Cl. 31 IS 4159:2021"(Resistance To Rusting) |
- |
0 |
|
- |
| "Cl. 102 IS 4159:2021"(Leakage and hydrostatic strength (for oil heating elements)) |
- |
0 |
|
- |
| Cl.22.106(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.2 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.3 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.10 of IS 302-1:2008(Power Input & Current) |
- |
0 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
0 |
|
- |
| Cl.11.2 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.11.101 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.18 of IS 4159:2021(Endurance Test) |
- |
0 |
|
- |
| Cl.19.2 of IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.3 of IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.22.101 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.102 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.103 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.104 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.105 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.106 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.107 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.108 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.109 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.110 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.111 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
0 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
0 |
|
- |
| Cl.28.1 & IS 302-1: 2008(Screws & Connection) |
- |
0 |
|
- |
| Cl.28.4 IS 302-1: 2008(Screws & Connection) |
- |
0 |
|
- |
| Cl. 29.1 & IS 302-1: 2008(Creepage Distances & Clearances) |
- |
0 |
|
- |
| Cl. 29.2 & IS 302-1: 2009(Creepage Distances & Clearances) |
- |
0 |
|
- |
| "Cl. 6 IS 4159:2021"(Classification) |
- |
0 |
|
- |
| "Cl. 8 IS 4159:2021"(Protection against access to live parts) |
- |
0 |
|
- |
| "Cl. 9 IS 4159:2021"(Starting of motor operated appliances) |
- |
0 |
|
- |
| "Cl. 10 IS 4159:2021"(Power Input and Current) |
- |
0 |
|
- |
| "Cl. 11 IS 4159:2021"(Heating) |
- |
0 |
|
- |
| "Cl. 13 IS 4159:2021"(Leakage Current & Electrical Strength at Operating Temperature) |
- |
0 |
|
- |
| "Cl. 14 IS 4159:2021"(Transient Over Voltage) |
- |
0 |
|
- |
| "Cl. 15 IS 4159:2021"(Moisture Resistance) |
- |
0 |
|
- |
| "Cl. 16 IS 4159:2021"(Leakage Current and Electric strength) |
- |
0 |
|
- |
| "Cl. 17 IS 4159:2021"(Overload protection of transformers and associated circuits.) |
- |
0 |
|
- |
| "Cl. 18 IS 4159:2021"(Endurance) |
- |
0 |
|
- |
| "Cl. 19 IS 4159:2021"(Abnormal Operation) |
- |
0 |
|
- |
| "Cl. 20 IS 4159:2021"(Stability and mechanical Hazards) |
- |
0 |
|
- |
| "Cl. 21 IS 4159:2021"(Mechanical Strength) |
- |
0 |
|
- |
| "Cl. 22 IS 4159:2021"(Construction) |
- |
0 |
|
- |
| "Cl. 23 IS 4159:2021"(Internal Wiring) |
- |
0 |
|
- |
| "Cl. 24 IS 4159:2021"(Components) |
- |
0 |
|
- |
| "Cl. 25 IS 4159:2021"(Supply Connections and External Flexible Cables and Cords) |
- |
0 |
|
- |
| "Cl. 26 IS 4159:2021"(Terminal For External Conductors) |
- |
0 |
|
- |
| "Cl. 27 IS 4159:2021"(Provision For Earthing) |
- |
0 |
|
- |
| "Cl. 28 IS 4159:2021"(Screws and Connections) |
- |
0 |
|
- |
| "Cl. 29 IS 4159:2021"(Creepage Distances, Clearances And Distances Through Insulation) |
- |
0 |
|
- |
| "Cl. 30 IS 4159:2021"(Resistance To Heat, Fire And Tracking) |
- |
0 |
|
- |
| "Cl. 31 IS 4159:2021"(Resistance To Rusting) |
- |
0 |
|
- |
| "Cl. 102 IS 4159:2021"(Leakage and hydrostatic strength (for oil heating elements)) |
- |
0 |
|
- |
| Cl.22.106(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.2 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.3 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.10 of IS 302-1:2008(Power Input & Current) |
- |
0 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
0 |
|
- |
| Cl.11.2 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.11.101 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.18 of IS 4159:2021(Endurance Test) |
- |
0 |
|
- |
| Cl.19.2 of IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.3 of IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.22.101 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.102 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.103 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.104 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.105 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.106 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.107 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.108 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.109 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.110 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.111 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
0 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
0 |
|
- |
| Cl.28.1 & IS 302-1: 2008(Screws & Connection) |
- |
0 |
|
- |
| Cl.28.4 IS 302-1: 2008(Screws & Connection) |
- |
0 |
|
- |
| Cl. 29.1 & IS 302-1: 2008(Creepage Distances & Clearances) |
- |
0 |
|
- |
| Cl. 29.2 & IS 302-1: 2009(Creepage Distances & Clearances) |
- |
0 |
|
- |
| "Cl. 6 IS 4159:2021"(Classification) |
- |
0 |
|
- |
| "Cl. 8 IS 4159:2021"(Protection against access to live parts) |
- |
0 |
|
- |
| "Cl. 9 IS 4159:2021"(Starting of motor operated appliances) |
- |
0 |
|
- |
| "Cl. 10 IS 4159:2021"(Power Input and Current) |
- |
0 |
|
- |
| "Cl. 11 IS 4159:2021"(Heating) |
- |
0 |
|
- |
| "Cl. 13 IS 4159:2021"(Leakage Current & Electrical Strength at Operating Temperature) |
- |
0 |
|
- |
| "Cl. 14 IS 4159:2021"(Transient Over Voltage) |
- |
0 |
|
- |
| "Cl. 15 IS 4159:2021"(Moisture Resistance) |
- |
0 |
|
- |
| "Cl. 16 IS 4159:2021"(Leakage Current and Electric strength) |
- |
0 |
|
- |
| "Cl. 17 IS 4159:2021"(Overload protection of transformers and associated circuits.) |
- |
0 |
|
- |
| "Cl. 18 IS 4159:2021"(Endurance) |
- |
0 |
|
- |
| "Cl. 19 IS 4159:2021"(Abnormal Operation) |
- |
0 |
|
- |
| "Cl. 20 IS 4159:2021"(Stability and mechanical Hazards) |
- |
0 |
|
- |
| "Cl. 21 IS 4159:2021"(Mechanical Strength) |
- |
0 |
|
- |
| "Cl. 22 IS 4159:2021"(Construction) |
- |
0 |
|
- |
| "Cl. 23 IS 4159:2021"(Internal Wiring) |
- |
0 |
|
- |
| "Cl. 24 IS 4159:2021"(Components) |
- |
0 |
|
- |
| "Cl. 25 IS 4159:2021"(Supply Connections and External Flexible Cables and Cords) |
- |
0 |
|
- |
| "Cl. 26 IS 4159:2021"(Terminal For External Conductors) |
- |
0 |
|
- |
| "Cl. 27 IS 4159:2021"(Provision For Earthing) |
- |
0 |
|
- |
| "Cl. 28 IS 4159:2021"(Screws and Connections) |
- |
0 |
|
- |
| "Cl. 29 IS 4159:2021"(Creepage Distances, Clearances And Distances Through Insulation) |
- |
0 |
|
- |
| "Cl. 30 IS 4159:2021"(Resistance To Heat, Fire And Tracking) |
- |
0 |
|
- |
| "Cl. 31 IS 4159:2021"(Resistance To Rusting) |
- |
0 |
|
- |
| "Cl. 102 IS 4159:2021"(Leakage and hydrostatic strength (for oil heating elements)) |
- |
0 |
|
- |
| Cl.22.106(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.1 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.2 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.7.3 of IS 4159:2021(Marking) |
- |
0 |
|
- |
| Cl.10 of IS 302-1:2008(Power Input & Current) |
- |
0 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
0 |
|
- |
| Cl.11 of IS 4159:2021 & IS 302‐1:2008(Heating) |
- |
0 |
|
- |
| Cl.11.2 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.11.101 of IS 4159:2021(Heating) |
- |
0 |
|
- |
| Cl.18 of IS 4159:2021(Endurance Test) |
- |
0 |
|
- |
| Cl.19.2 of IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.3 of IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.19.13 IS 302-1: 2008(Abnormal Operation) |
- |
0 |
|
- |
| Cl.22.101 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.102 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.103 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.104 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.105 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.106 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.107 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.108 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.109 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.110 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.22.111 of IS 4159:2021(Construction) |
- |
0 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
0 |
|
- |
| Cl.27 & IS 302-1: 2008(Provision for Earthing) |
- |
0 |
|
- |
| Cl.28.1 & IS 302-1: 2008(Screws & Connection) |
- |
0 |
|
- |
| Cl.28.4 IS 302-1: 2008(Screws & Connection) |
- |
0 |
|
- |
| Cl. 29.1 & IS 302-1: 2008(Creepage Distances & Clearances) |
- |
0 |
|
- |
| Cl. 29.2 & IS 302-1: 2009(Creepage Distances & Clearances) |
- |
0 |
|
- |
|
- |
- Included w.e.f.10.09.2025
Exclusion
Cl 19.11.4.1 to Cl 19.11.4.7 EMI/EMC |
| 3774 |
Atmy Analytical Labs Pvt. Ltd., Faridabad
| 8167506
| IS 209 (2024) |
Refined Zinc - Specification (Fifth Revision) |
ALL |
9900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Zinc)) |
- |
1000 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Lead)) |
- |
1000 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Iron)) |
- |
1000 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Cadmium)) |
- |
1000 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Aluminium)) |
- |
1000 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Copper)) |
- |
1000 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Tin)) |
- |
1000 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Total of All Impurities)) |
- |
1500 |
|
- |
| Cl 9.1(Freedom from Defect) |
- |
1500 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Zinc)) |
- |
0 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Lead)) |
- |
0 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Iron)) |
- |
0 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Cadmium)) |
- |
0 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Aluminium)) |
- |
0 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Copper)) |
- |
0 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Tin)) |
- |
0 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Total of All Impurities)) |
- |
0 |
|
- |
| Cl 9.1(Freedom from Defect) |
- |
0 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Zinc)) |
- |
0 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Lead)) |
- |
0 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Iron)) |
- |
0 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Cadmium)) |
- |
0 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Aluminium)) |
- |
0 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Copper)) |
- |
0 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Tin)) |
- |
0 |
|
- |
| Cl 7.1, Cl 7.2 & Table 1(Chemical Composition (Total of All Impurities)) |
- |
0 |
|
- |
| Cl 9.1(Freedom from Defect) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 13.11.2025 |
| 3775 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/41), GHAZIABAD
| 9179706
| IS 10702 (2023) |
Hawai Chappal-Specification |
ALL |
40500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Material) |
- |
500 |
|
- |
| 4.2(Length) |
- |
400 |
|
- |
| 4.3(Thickness) |
- |
400 |
|
- |
| 4.4 , Table No. 1 , i)(Density) |
- |
600 |
|
- |
| 4.4 , Table No. 1 , ii)(2Compression set at constant stress) |
- |
500 |
|
- |
| 4.4 , Table No. 1 , iii)(3Split tear strength) |
- |
700 |
|
- |
| 4.4 , Table No. 1 , iv)("Shrinkage at 50 ºC ± 1 ºC for 24 h for polymeric material,
Shrinkage at 100 ºC ± 1 ºC for 1 h for rubber") |
- |
600 |
|
- |
| 4.4 , Table No. 1 , v)(5Abrasion resistance at applied force) |
- |
700 |
|
- |
| 4.4 , Table No. 1 , vi)(Flexing resistance: Maximum cut growth at 50 000 flexes) |
- |
600 |
|
- |
| 4.4 , Table No. 1 , vii)(7 Hydrolysis resistance, Maximum cut growth at 50 000 flexes) |
- |
700 |
|
- |
| 4.4 , Table No . 2 , i)(Density , Solid strap, Cellular strap) |
- |
600 |
|
- |
| 4.4 , Table No . 2 , ii)("Breaking strength , Strap to strap and
Toe portion to strap , Elongation at break") |
- |
1000 |
|
- |
| 4.4 , Table No . 2 , iii)(Minimum cross section of the stud) |
- |
600 |
|
- |
| 4.4 , Table No . 2 , iv)(Stud bolt) |
- |
400 |
|
- |
| 4.4 , Table No . 3 , i)(Toe post attachment strength) |
- |
500 |
|
- |
| 4.4 , Table No . 3 , ii)(Attachment strength of rear strap) |
- |
1000 |
|
- |
| 4.4 , Table No . 3 , iii)(Inter layer bond strength) |
- |
1000 |
|
- |
| 5(CHEMICAL REQUIREMENT FOR HAWAI CHAPPAL) |
- |
1000 |
|
- |
| 6(MARKING AND PACKING) |
- |
500 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(i)(Allergenic and carcinogenic disperse dyes) |
- |
700 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
700 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
800 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(iv)(Chromium (VI)) |
- |
700 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(v)(Dimethyl fumarate (DMFU)) |
- |
600 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
500 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(vii)(Formaldehyde) |
- |
500 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(viii)(Organotin compounds) |
- |
700 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
1000 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(x)(pH) |
- |
500 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(xi)(Phthalates (each individual phthalate)) |
- |
1000 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(xii)(Nickel, on skin contact 2-(thiocyanomethylthio) -benzothiazole (TCMTB)) |
- |
1000 |
|
- |
| Cl.No. 5.2(lead content) |
- |
700 |
|
- |
| Clause 4.1 - 4.1.1(Bottom Material) |
- |
500 |
|
- |
| Clause 4.1 - 4.1.2(Strap Material) |
- |
400 |
|
- |
| Clause 4.1 - 4.1.3(Material) |
- |
500 |
|
- |
| Clause 4.1 - 4.1.4(Material) |
- |
500 |
|
- |
| Clause 4.2(Material) |
- |
500 |
|
- |
| Clause 4.3 - 4.3.1(Thickness) |
- |
400 |
|
- |
| Clause 4.3 - 4.3.2(Thickness) |
- |
400 |
|
- |
| Clause 4.4 Table 1 -i)(Density, g/cm3, Min) |
- |
500 |
|
- |
| Clause 4.4 Table 1 -iii)(Split tear strength, kg, Min) |
- |
800 |
|
- |
| Clause 4.4 Table 1 -iv) - a("Shrinkage at 50 ºC ± 1 ºC for 24 h for polymeric material, percent,
Max") |
- |
800 |
|
- |
| Clause 4.4 Table 1 -iv) - b(Shrinkage at 100 ºC ± 1 ºC for 1 h for rubber, percent, Max) |
- |
800 |
|
- |
| Clause 4.4 Table 1 -v)(Abrasion resistance at applied force 5 N) |
- |
800 |
|
- |
| Clause 4.4 Table 2 -i) - a("Density, g/cm3
Solid strap
") |
- |
500 |
|
- |
| Clause 4.4 Table 2 -i) - b(Density, g/cm3 Cellular strap) |
- |
500 |
|
- |
| Clause 4.4 Table 2 -ii) - a - 1("Breaking strength, kgf, Min
Strap to strap(Solid Strap)") |
- |
1000 |
|
- |
| Clause 4.4 Table 2 -ii) - a - 2("Breaking strength, kgf, Min
Strap to strap(Cellular Strap)") |
- |
1000 |
|
- |
| Clause 4.4 Table 2 -ii) - a - 3("Breaking strength, kgf, Min
Toe portion to strap(Solid Strap)") |
- |
1000 |
|
- |
| Clause 4.4 Table 2 -ii) - a - 4("Breaking strength, kgf, Min
Toe portion to strap(Cellular Strap)") |
- |
1000 |
|
- |
| Clause 4.4 Table 2 -ii) - b - 1("Elongation at break, percent
(Applicable to strap to strap
(V shape) Solid Strap") |
- |
500 |
|
- |
| Clause 4.4 Table 2 -ii) - b - 2("Elongation at break, percent
(Applicable to strap to strap
(V shape) Cellular Strap") |
- |
500 |
|
- |
| Clause 4.4 Table 2 -iii) - a("Minimum cross section of the
stud, mm,
Size 1 to 13 (Adult)") |
- |
400 |
|
- |
| Clause 4.4 Table 2 -iii) - b("Minimum cross section of the
stud, mm,
Size 3 to 13 (Children)") |
- |
400 |
|
- |
| Clause 4.4 Table 2 -iv) - a("Stud bolt, mm
Diameter/edge to edge length") |
- |
400 |
|
- |
| Clause 4.4 Table 2 -iv) - b("Stud bolt, mm
Thickness") |
- |
400 |
|
- |
| Clause 4.4 Table 3 -i)("Toe post attachment strength, N,
Min") |
- |
500 |
|
- |
| Clause 4.4 Table 3 -ii)("Attachment strength of rear strap,
N, Min") |
- |
1000 |
|
- |
| Clause 4.4 Table 3 -iii)("Inter layer bond strength, N/mm,
Min") |
- |
1000 |
|
- |
| Cl-4 ((Amendment No-1)(Category And Type) |
- |
1000 |
|
- |
| Cl-4.4, Table -1 S. No-1 (i) (Amendment No-1)(Compression set at constant stress) |
- |
700 |
|
- |
| Cl-4.4, Table -1 S. No-1 (ii) (Amendment No-1)(Split tear strength) |
- |
700 |
|
- |
| Cl-4.4, Table -1 S. No-1 (iii) (a)(Amendment No-1)("Shrinkage at Shrinkage at 50 °C ± 1 °C for 2 h for polymeric material, percent, Max
") |
- |
800 |
|
- |
| Cl-4.4, Table -1 S. No-1 (iii)(b) (Amendment No-1)(Shrinkage at 100 °C ± 1 °C for 1 h for rubber, percent, Max) |
- |
600 |
|
- |
| Cl-4.4, Table -1 S. No-1 (iv) (Amendment No-1)(Abrasion resistance at applied force) |
- |
700 |
|
- |
| Cl-4.4, Table -1 S. No-1 (v) (Amendment No-1)(Flexing resistance: Maximum cut growth,) |
- |
700 |
|
- |
| Cl-4.4, Table -1 S. No-1 (vi) (Amendment No-1)(Hydrolysis resistance:Maximum cut growth) |
- |
700 |
|
- |
| Cl-4.4, Table -1 S. No-1 (vii) (Amendment No-1)(Chemical requirements) |
- |
700 |
|
- |
| Cl-4.4, Table -1 S. No-1 (viii) (Amendment No-1)("Lead content (as Pb),
ppm, Max") |
- |
700 |
|
- |
| Cl-4.4, Table -2 S. No-1 (i), a (Amendment No-1)("Breaking strength for Strap to strap
1-Solid strap
2-Cellular strap") |
- |
700 |
|
- |
| Cl-4.4, Table -2 S. No-1 (i), b (Amendment No-1)("Breaking strength for Toe portion to strap
1-Solid strap
2-Cellular strap") |
- |
700 |
|
- |
| Cl-4.4, Table -2 S. No-1 (i), c (Amendment No-1)("Elongation at break , percent, Min
1-Solid strap
2-Cellular strap") |
- |
700 |
|
- |
| Cl-4.4, Table -2 S. No-1 (ii), (Amendment No-1)(Chemical requirements) |
- |
700 |
|
- |
| Cl-4.4, Table -2 S. No-1 (iii), (Amendment No-1)(Lead content (as Pb), in ppm, Max) |
- |
700 |
|
- |
| Cl-4.4, Table -3 S. No-1 (i), (Amendment No-1)(Toe post attachment strength) |
- |
700 |
|
- |
| Cl-4.4, Table -3 S. No-1 (ii), (Amendment No-1)(Attachment strength of rear strap) |
- |
700 |
|
- |
| Cl-4.4, Table -3 S. No-1 (iii), (Amendment No-1)(Inter layer bond strength) |
- |
600 |
|
- |
| Cl.4.4 - Table No 1 - Sl. No.-vii(pH- IS 1390:2022) |
- |
500 |
|
- |
| Cl.4.4 - Table No 1 - Sl. No.-viii("Lead Content (as Pb) (applicable for PVC only)
- IS 12240 (Part 5) : 1988") |
- |
700 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl I )(Phthalate: DINP) |
- |
600 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl II )(Phthalate:: DNOP) |
- |
700 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl III )(Phthalate: DEHP) |
- |
700 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl IV )(Phthalate: DIDP) |
- |
600 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl V)(Phthalate: BBP) |
- |
600 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl VI )(Phthalate:DBP) |
- |
600 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl VII )(Phthalate: DIBP) |
- |
600 |
|
- |
| Cl.4.1 (Annex-A Sl I )(Organotin: Dibutyltin) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl II )(Organotin: Dibutyltin Dichloride) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl III )(Organotin: Dioctyltin) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl IV)(Organotin: Monobutyltin) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl V )(Organotin: Tributyltin) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl VI)(Organotin: Triphenyltin) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl VII )(Organotin: Monoctyltin) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl VIII)(Organotin: Bis (tributyltin) oxide) |
- |
1000 |
|
- |
| Hawai Chappal-Specification(Formaldehyde (free or released by partial hydrolysis)) |
- |
1000 |
|
- |
| Cl. No.8.6.1,Table 1 of IS 17011(Nickel, on skin contact 2-(thiocyanomethylthio) -benzothiazole (TCMTB)) |
- |
700 |
|
- |
| Cl.8 - Table No 1(Lead Content (as Pb) (applicable for PVC only) - IS 12240 (Part 5) : 1988) |
- |
600 |
|
- |
| Cl.4.1 (Table B-3)(Allergenic and Carcinogenic Disperse Dyes) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl I)(Aromatic Amines: 4-aminobiphenyl) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl II)(Aromatic Amines: Benzidine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl III)(Aromatic Amines: 4-chloro-o-toluidine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl IV)(Aromatic Amines: 2-naphthylamine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl V)(Aromatic Amines :o-aminoazotoluene) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl VI)(Aromatic Amines: 2-amino-4-nitrotoluenem) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl VII)(Aromatic Amines: p-chloroaniline) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl VIII)(Aromatic Amines: 2,4-diaminoanisole) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl IX)(Aromatic Amines : 4,4’- diaminodiphenylmethane:) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl X)(Aromatic Amines : 3,3’-dichlorobenzidine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XI)(Aromatic Amines : 3,3’-dimethoxybenzidine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XII)(Aromatic Amines : 3,3’-dimethylbenzidine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XIII)(Aromatic Amines: 3,3’-dimethyl-4,4’-diaminodiphenylmethane) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XIV)(Aromatic Amines : p-cresidine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XV)(Aromatic Amines : 4,4’-methylene-bis(2-chloroaniline):) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XVI)(Aromatic Amines :4,4’-oxydianiline) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XVII)(Aromatic Amines:4,4’-thiodianiline) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XVIII)(Aromatic Amines :o-toluidine:) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XIX)(Aromatic Amines: 2,4-toluylendiamine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XX)(Aromatic Amines: 2,4,5-trimethylaniline) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XXI)(Aromatic Amines :2,4-dimethylaniline) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XXII)(Aromatic Amines: 2,6-dimethylaniline:) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XXIII)(Aromatic Amines :2-methoxyaniline) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XXIV)(Aromatic Amines :4-aminoazobenzene) |
- |
1000 |
|
- |
| 4.1(Material) |
- |
700 |
|
- |
| 4.2(Length) |
- |
600 |
|
- |
| 4.3(Thickness) |
- |
600 |
|
- |
| 4.4 , Table No. 1 , i)(Density) |
- |
600 |
|
- |
| 4.4 , Table No. 1 , ii)(2Compression set at constant stress) |
- |
700 |
|
- |
| 4.4 , Table No. 1 , iii)(3Split tear strength) |
- |
800 |
|
- |
| 4.4 , Table No. 1 , iv)("Shrinkage at 50 ºC ± 1 ºC for 24 h for polymeric material,
Shrinkage at 100 ºC ± 1 ºC for 1 h for rubber") |
- |
700 |
|
- |
| 4.4 , Table No. 1 , v)(5Abrasion resistance at applied force) |
- |
700 |
|
- |
| 4.4 , Table No. 1 , vi)(Flexing resistance: Maximum cut growth at 50 000 flexes) |
- |
500 |
|
- |
| 4.4 , Table No. 1 , vii)(7 Hydrolysis resistance, Maximum cut growth at 50 000 flexes) |
- |
800 |
|
- |
| 4.4 , Table No . 2 , i)(Density , Solid strap, Cellular strap) |
- |
700 |
|
- |
| 4.4 , Table No . 2 , ii)("Breaking strength , Strap to strap and
Toe portion to strap , Elongation at break") |
- |
700 |
|
- |
| 4.4 , Table No . 2 , iii)(Minimum cross section of the stud) |
- |
700 |
|
- |
| 4.4 , Table No . 2 , iv)(Stud bolt) |
- |
500 |
|
- |
| 4.4 , Table No . 3 , i)(Toe post attachment strength) |
- |
500 |
|
- |
| 4.4 , Table No . 3 , ii)(Attachment strength of rear strap) |
- |
500 |
|
- |
| 4.4 , Table No . 3 , iii)(Inter layer bond strength) |
- |
700 |
|
- |
| 5(CHEMICAL REQUIREMENT FOR HAWAI CHAPPAL) |
- |
700 |
|
- |
| 6(MARKING AND PACKING) |
- |
500 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(i)(Allergenic and carcinogenic disperse dyes) |
- |
500 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
500 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
500 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(iv)(Chromium (VI)) |
- |
500 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(v)(Dimethyl fumarate (DMFU)) |
- |
700 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
700 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(vii)(Formaldehyde) |
- |
700 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(viii)(Organotin compounds) |
- |
700 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
500 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(x)(pH) |
- |
500 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(xi)(Phthalates (each individual phthalate)) |
- |
700 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(xii)(Nickel, on skin contact 2-(thiocyanomethylthio) -benzothiazole (TCMTB)) |
- |
1000 |
|
- |
| Cl.No. 5.2(lead content) |
- |
1000 |
|
- |
| Clause 4.1 - 4.1.1(Bottom Material) |
- |
1000 |
|
- |
| Clause 4.1 - 4.1.2(Strap Material) |
- |
1000 |
|
- |
| Clause 4.1 - 4.1.3(Material) |
- |
500 |
|
- |
| Clause 4.1 - 4.1.4(Material) |
- |
1000 |
|
- |
| Clause 4.2(Material) |
- |
1000 |
|
- |
| Clause 4.3 - 4.3.1(Thickness) |
- |
500 |
|
- |
| Clause 4.3 - 4.3.2(Thickness) |
- |
500 |
|
- |
| Clause 4.4 Table 1 -i)(Density, g/cm3, Min) |
- |
700 |
|
- |
| Clause 4.4 Table 1 -iii)(Split tear strength, kg, Min) |
- |
700 |
|
- |
| Clause 4.4 Table 1 -iv) - a("Shrinkage at 50 ºC ± 1 ºC for 24 h for polymeric material, percent,
Max") |
- |
700 |
|
- |
| Clause 4.4 Table 1 -iv) - b(Shrinkage at 100 ºC ± 1 ºC for 1 h for rubber, percent, Max) |
- |
700 |
|
- |
| Clause 4.4 Table 1 -v)(Abrasion resistance at applied force 5 N) |
- |
700 |
|
- |
| Clause 4.4 Table 2 -i) - a("Density, g/cm3
Solid strap
") |
- |
60070 |
|
- |
| Clause 4.4 Table 2 -i) - b(Density, g/cm3 Cellular strap) |
- |
700 |
|
- |
| Clause 4.4 Table 2 -ii) - a - 1("Breaking strength, kgf, Min
Strap to strap(Solid Strap)") |
- |
700 |
|
- |
| Clause 4.4 Table 2 -ii) - a - 2("Breaking strength, kgf, Min
Strap to strap(Cellular Strap)") |
- |
800 |
|
- |
| Clause 4.4 Table 2 -ii) - a - 3("Breaking strength, kgf, Min
Toe portion to strap(Solid Strap)") |
- |
700 |
|
- |
| Clause 4.4 Table 2 -ii) - a - 4("Breaking strength, kgf, Min
Toe portion to strap(Cellular Strap)") |
- |
700 |
|
- |
| Clause 4.4 Table 2 -ii) - b - 1("Elongation at break, percent
(Applicable to strap to strap
(V shape) Solid Strap") |
- |
700 |
|
- |
| Clause 4.4 Table 2 -ii) - b - 2("Elongation at break, percent
(Applicable to strap to strap
(V shape) Cellular Strap") |
- |
700 |
|
- |
| Clause 4.4 Table 2 -iii) - a("Minimum cross section of the
stud, mm,
Size 1 to 13 (Adult)") |
- |
700 |
|
- |
| Clause 4.4 Table 2 -iii) - b("Minimum cross section of the
stud, mm,
Size 3 to 13 (Children)") |
- |
700 |
|
- |
| Clause 4.4 Table 2 -iv) - a("Stud bolt, mm
Diameter/edge to edge length") |
- |
700 |
|
- |
| Clause 4.4 Table 2 -iv) - b("Stud bolt, mm
Thickness") |
- |
700 |
|
- |
| Clause 4.4 Table 3 -i)("Toe post attachment strength, N,
Min") |
- |
800 |
|
- |
| Clause 4.4 Table 3 -ii)("Attachment strength of rear strap,
N, Min") |
- |
700 |
|
- |
| Clause 4.4 Table 3 -iii)("Inter layer bond strength, N/mm,
Min") |
- |
800 |
|
- |
| Cl-4 ((Amendment No-1)(Category And Type) |
- |
700 |
|
- |
| Cl-4.4, Table -1 S. No-1 (i) (Amendment No-1)(Compression set at constant stress) |
- |
800 |
|
- |
| Cl-4.4, Table -1 S. No-1 (ii) (Amendment No-1)(Split tear strength) |
- |
700 |
|
- |
| Cl-4.4, Table -1 S. No-1 (iii) (a)(Amendment No-1)("Shrinkage at Shrinkage at 50 °C ± 1 °C for 2 h for polymeric material, percent, Max
") |
- |
700 |
|
- |
| Cl-4.4, Table -1 S. No-1 (iii)(b) (Amendment No-1)(Shrinkage at 100 °C ± 1 °C for 1 h for rubber, percent, Max) |
- |
600 |
|
- |
| Cl-4.4, Table -1 S. No-1 (iv) (Amendment No-1)(Abrasion resistance at applied force) |
- |
600 |
|
- |
| Cl-4.4, Table -1 S. No-1 (v) (Amendment No-1)(Flexing resistance: Maximum cut growth,) |
- |
700 |
|
- |
| Cl-4.4, Table -1 S. No-1 (vi) (Amendment No-1)(Hydrolysis resistance:Maximum cut growth) |
- |
700 |
|
- |
| Cl-4.4, Table -1 S. No-1 (vii) (Amendment No-1)(Chemical requirements) |
- |
600 |
|
- |
| Cl-4.4, Table -1 S. No-1 (viii) (Amendment No-1)("Lead content (as Pb),
ppm, Max") |
- |
700 |
|
- |
| Cl-4.4, Table -2 S. No-1 (i), a (Amendment No-1)("Breaking strength for Strap to strap
1-Solid strap
2-Cellular strap") |
- |
1000 |
|
- |
| Cl-4.4, Table -2 S. No-1 (i), b (Amendment No-1)("Breaking strength for Toe portion to strap
1-Solid strap
2-Cellular strap") |
- |
1000 |
|
- |
| Cl-4.4, Table -2 S. No-1 (i), c (Amendment No-1)("Elongation at break , percent, Min
1-Solid strap
2-Cellular strap") |
- |
1000 |
|
- |
| Cl-4.4, Table -2 S. No-1 (ii), (Amendment No-1)(Chemical requirements) |
- |
1000 |
|
- |
| Cl-4.4, Table -2 S. No-1 (iii), (Amendment No-1)(Lead content (as Pb), in ppm, Max) |
- |
1000 |
|
- |
| Cl-4.4, Table -3 S. No-1 (i), (Amendment No-1)(Toe post attachment strength) |
- |
1000 |
|
- |
| Cl-4.4, Table -3 S. No-1 (ii), (Amendment No-1)(Attachment strength of rear strap) |
- |
1000 |
|
- |
| Cl-4.4, Table -3 S. No-1 (iii), (Amendment No-1)(Inter layer bond strength) |
- |
1000 |
|
- |
| Cl.4.4 - Table No 1 - Sl. No.-vii(pH- IS 1390:2022) |
- |
500 |
|
- |
| Cl.4.4 - Table No 1 - Sl. No.-viii("Lead Content (as Pb) (applicable for PVC only)
- IS 12240 (Part 5) : 1988") |
- |
700 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl I )(Phthalate: DINP) |
- |
1000 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl II )(Phthalate:: DNOP) |
- |
1000 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl III )(Phthalate: DEHP) |
- |
1000 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl IV )(Phthalate: DIDP) |
- |
1000 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl V)(Phthalate: BBP) |
- |
1000 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl VI )(Phthalate:DBP) |
- |
1000 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl VII )(Phthalate: DIBP) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl I )(Organotin: Dibutyltin) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl II )(Organotin: Dibutyltin Dichloride) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl III )(Organotin: Dioctyltin) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl IV)(Organotin: Monobutyltin) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl V )(Organotin: Tributyltin) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl VI)(Organotin: Triphenyltin) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl VII )(Organotin: Monoctyltin) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl VIII)(Organotin: Bis (tributyltin) oxide) |
- |
1000 |
|
- |
| Hawai Chappal-Specification(Formaldehyde (free or released by partial hydrolysis)) |
- |
1000 |
|
- |
| Cl. No.8.6.1,Table 1 of IS 17011(Nickel, on skin contact 2-(thiocyanomethylthio) -benzothiazole (TCMTB)) |
- |
1000 |
|
- |
| Cl.8 - Table No 1(Lead Content (as Pb) (applicable for PVC only) - IS 12240 (Part 5) : 1988) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-3)(Allergenic and Carcinogenic Disperse Dyes) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl I)(Aromatic Amines: 4-aminobiphenyl) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl II)(Aromatic Amines: Benzidine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl III)(Aromatic Amines: 4-chloro-o-toluidine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl IV)(Aromatic Amines: 2-naphthylamine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl V)(Aromatic Amines :o-aminoazotoluene) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl VI)(Aromatic Amines: 2-amino-4-nitrotoluenem) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl VII)(Aromatic Amines: p-chloroaniline) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl VIII)(Aromatic Amines: 2,4-diaminoanisole) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl IX)(Aromatic Amines : 4,4’- diaminodiphenylmethane:) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl X)(Aromatic Amines : 3,3’-dichlorobenzidine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XI)(Aromatic Amines : 3,3’-dimethoxybenzidine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XII)(Aromatic Amines : 3,3’-dimethylbenzidine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XIII)(Aromatic Amines: 3,3’-dimethyl-4,4’-diaminodiphenylmethane) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XIV)(Aromatic Amines : p-cresidine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XV)(Aromatic Amines : 4,4’-methylene-bis(2-chloroaniline):) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XVI)(Aromatic Amines :4,4’-oxydianiline) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XVII)(Aromatic Amines:4,4’-thiodianiline) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XVIII)(Aromatic Amines :o-toluidine:) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XIX)(Aromatic Amines: 2,4-toluylendiamine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XX)(Aromatic Amines: 2,4,5-trimethylaniline) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XXI)(Aromatic Amines :2,4-dimethylaniline) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XXII)(Aromatic Amines: 2,6-dimethylaniline:) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XXIII)(Aromatic Amines :2-methoxyaniline) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XXIV)(Aromatic Amines :4-aminoazobenzene) |
- |
1000 |
|
- |
|
- |
- Included w.e.f 04.11.2025 |
| 3776 |
Atmy Analytical Labs Pvt. Ltd., Faridabad
| 8167506
| IS 17631 (2022) |
Work Chairs - Specification |
All |
79000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| clause 4(DESIGN AND WORKMANSHIP) |
- |
4500 |
|
- |
| clause 5(DIMENSIONS) |
- |
2500 |
|
- |
| Cl-6.1 (a)(Resistance to mechanical damage) |
- |
1000 |
|
- |
| Cl-6.2 (a) (1)(For Fabric and Synthetic Leather:- Breaking load) |
- |
1500 |
|
- |
| Cl-7.3.1(Front Edge Overturning) |
- |
5500 |
|
- |
| Cl-7.3.2(Forwards Overturning) |
- |
5000 |
|
- |
| Cl-7.3.3(Forwards Overturning for Chairs with Foot Rest) |
- |
5500 |
|
- |
| Cl-7.3.4(Sideways Overturning for Chairs Without Arm Rests) |
- |
8000 |
|
- |
| Cl-6.1 (b)(Pencil hardness) |
- |
1000 |
|
- |
| Cl-6.1 (c)(Resistance to wet heat;) |
- |
1000 |
|
- |
| Cl-6.1 (d)(Resistance to dry heat;) |
- |
1500 |
|
- |
| Cl-6.1 (e)(Resistance to marking by cold liquids) |
- |
1500 |
|
- |
| Cl-6.1 (f)(Resistance to marking by cold oils and fats;) |
- |
1500 |
|
- |
| Cl-6.1 (g)(Adhesive performance) |
- |
1000 |
|
- |
| Cl-6.2 (a) (2)(For Fabric and Synthetic Leather:- Elongation at break) |
- |
1000 |
|
- |
| Cl-6.2 (a) (3)(For Fabric and Synthetic Leather:- Tear strength) |
- |
500 |
|
- |
| Cl-6.2 (a) (4)(For Fabric and Synthetic Leather:- Colour fastness to light) |
- |
1500 |
|
- |
| Cl-6.2 (a) (5)(For Fabric and Synthetic Leather:- Colour fastness to rubbing) |
- |
1500 |
|
- |
| Cl-6.2 (a) (6)(For Fabric and Synthetic Leather:- Colour fastness to perspiration) |
- |
2000 |
|
- |
| Cl-6.2 (a) (7)(For Fabric and Synthetic Leather:- Colour fastness to water) |
- |
2000 |
|
- |
| Cl-6.2 (a) (8)(For Fabric and Synthetic Leather:- Pilling resistance) |
- |
1000 |
|
- |
| Cl-6.2 (a) (9)(For Fabric and Synthetic Leather:- Coating adhesion strength) |
- |
500 |
|
- |
| Cl-6.2 (a) (10)(For Fabric and Synthetic Leather:- Seam slippage) |
- |
1000 |
|
- |
| Cl-6.2 (a) (11)(For Fabric and Synthetic Leather:- Resistance to damage by flexing) |
- |
1000 |
|
- |
| Cl-6.2 (a) (12)(For Fabric and Synthetic Leather:- Abrasion resistance) |
- |
1500 |
|
- |
| Cl-6.2 (a) (13)(For Fabric and Synthetic Leather:- Bursting strength) |
- |
1000 |
|
- |
| Cl-6.2 (a) (14)(For Fabric and Synthetic Leather:- Resistance to cold) |
- |
1000 |
|
- |
| Cl-6.2 (b) (2)(For Natural Leather:- Flexing endurance) |
- |
1500 |
|
- |
| Cl-6.2 (b) (1)(For Natural Leather:- Tear strength) |
- |
1000 |
|
- |
| Cl-6.2 (b) (3)(For Natural Leather: Finish adhesion) |
- |
1000 |
|
- |
| Cl-6.2 (b) (4)(For Natural Leather: Colour fastness to artificial light) |
- |
1500 |
|
- |
| Cl-6.2 (b) (5)(For Natural Leather: Colour fastness to rubbing) |
- |
1000 |
|
- |
| Cl-6.2 (b) (6)(For Natural Leather: Colour fastness to water spotting) |
- |
1500 |
|
- |
| Cl-6.2 (b) (7)(For Natural Leather: Water vapour permeability) |
- |
1000 |
|
- |
| Cl-6.2 (b) (8)(For Natural Leather: Colour fastness to water) |
- |
1000 |
|
- |
| Cl-7.3.5(Sideways Overturning for Chairs With Arm Rests) |
- |
4500 |
|
- |
| Cl-7.3.6(Rearwards Overturning for Chairs Without Back Rest Inclination) |
- |
1500 |
|
- |
| Cl-7.3.7(Rearwards Overturning for Chairs with Backrest Inclination) |
- |
1500 |
|
- |
| Cl-7.4.1(Seat Front Edge Static Load Test) |
- |
1500 |
|
- |
| Cl-7.4.2(Combined Seat and Back Static Load Test) |
- |
2000 |
|
- |
| Cl-7.4.3(Arm Rest Downward Static Load Test — Central) |
- |
2000 |
|
- |
| Cl-7.4.4(Arm Rest Downward Static Load Test — Front) |
- |
1500 |
|
- |
| Cl-7.4.5(Arm Rest Sideways Static Load Test) |
- |
2500 |
|
- |
| Cl-7.4.6(Foot Rest Static Load Test) |
- |
2000 |
|
- |
| Cl-7.5.1(Seat and Back Durability) |
- |
21000 |
|
- |
| Cl-7.5.2(Arm Rest Durability) |
- |
20000 |
|
- |
| Cl-7.5.3(Swivel Test) |
- |
18000 |
|
- |
| Cl-7.5.4(Foot-rest Durability) |
- |
15000 |
|
- |
| Cl-7.5.5(Castor and Chair-Base Durability) |
- |
18000 |
|
- |
|
25 Feb, 2027 |
- - |
| 3777 |
Atmy Analytical Labs Pvt. Ltd., Faridabad
| 8167506
| IS 17634 (2022) |
Storage Units - Specification |
- |
33000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| CLAUSE 5(DIMENSIONS) |
- |
4500 |
|
- |
| CLAUSE 6.2(Fabric and Leather (Synthetic and Natural) Performance) |
- |
5500 |
|
- |
| CLAUSE 6(SURFACE PERFORMANCE) |
- |
9000 |
|
- |
| CLAUSE 7.1(SAFETY TESTS (General)) |
- |
1000 |
|
- |
| CLAUSE 7.2(Test for Non-Movable Parts) |
- |
0 |
|
- |
| CLAUSE 7.2.1(Shelves) |
- |
2500 |
|
- |
| CLAUSE 7.2.1.2(Deflection of shelves) |
- |
2500 |
|
- |
| CLAUSE 7.2.2.1(Sustained load test for tops and bottoms) |
- |
2500 |
|
- |
| CLAUSE 7.2.2.2(Static load test for tops and bottoms) |
- |
2500 |
|
- |
| CLAUSE 7.2.3.1(Strength of clothes-rail supports) |
- |
2500 |
|
- |
| CLAUSE 7.2.3.2(Dislodgement of clothes rail) |
- |
2500 |
|
- |
| CLAUSE 7.2.4.2(Drop test) |
- |
2500 |
|
- |
| CLAUSE 7.2.4.3(Tests for units with castors or wheels) |
- |
2500 |
|
- |
| CLAUSE 7.3.1(Pivoted Doors) |
- |
2500 |
|
- |
| CLAUSE 7.3.1.2.1(Vertical load on pivoted door) |
- |
2500 |
|
- |
| CLAUSE 7.3.1.2.2(Horizontal load on pivoted door) |
- |
2500 |
|
- |
| CLAUSE 7.3.1.3(Slam-shut test of pivoted doors) |
- |
2500 |
|
- |
| CLAUSE 7.3.1.4(Durability of pivoted doors) |
- |
2500 |
|
- |
| Cl-6.1 (a)(Resistance to mechanical damage) |
- |
4500 |
|
- |
| Cl-6.1 (b)(Pencil hardness) |
- |
1500 |
|
- |
| Cl-6.1 (c)(Resistance to wet heat) |
- |
9000 |
|
- |
| Cl-6.1 (d)Cl-6.1 (d)(Resistance to dry heat) |
- |
9000 |
|
- |
| Cl-6.1 (e)(Resistance to marking by cold liquids) |
- |
5000 |
|
- |
| Cl-6.1 (f)(Resistance to marking by cold oils and fats
Resistance to marking by cold oils and fats) |
- |
3000 |
|
- |
| Cl-6.1 (g)(Adhesive performance) |
- |
3500 |
|
- |
| Cl-6.2 (a) 1(Breaking load) |
- |
2500 |
|
- |
| Cl-6.2 (a) 2(Elongation at break) |
- |
2500 |
|
- |
| Cl-6.2 (a) 3(Tear strength) |
- |
2500 |
|
- |
| Cl-6.2 (a) 4(Colour fastness to light) |
- |
5000 |
|
- |
| Cl-6.2 (a) 5(Colour fastness to rubbing) |
- |
2500 |
|
- |
| Cl-6.2 (a) 6(Colour fastness to perspiration) |
- |
1500 |
|
- |
| Cl-6.2 (a) 7(Colour fastness to water) |
- |
1500 |
|
- |
| Cl-6.2 (a) 8(Pilling resistance) |
- |
2500 |
|
- |
| Cl-6.2 (a) 9(Coating adhesion strength) |
- |
2500 |
|
- |
| Cl-6.2 (a) 10(Seam slippage) |
- |
2500 |
|
- |
| Cl-6.2 (a) 11(Resistance to damage by flexing) |
- |
2500 |
|
- |
| Cl-6.2 (a) 12(Abrasion resistance) |
- |
3000 |
|
- |
| Cl-6.2 (a) 13(Bursting strength) |
- |
1500 |
|
- |
| Cl-6.2 (a) 14(Resistance to cold) |
- |
2000 |
|
- |
| Cl-6.2 (b) 1(Tear strength) |
- |
2500 |
|
- |
| Cl-6.2 (b) 2(Flexing endurance) |
- |
4000 |
|
- |
| Cl-6.2 (b) 3(Finish adhesion) |
- |
2500 |
|
- |
| Cl-6.2 (b) 4(Colour fastness to artificial light) |
- |
5000 |
|
- |
| Cl-6.2 (b) 5(Colour fastness to rubbing) |
- |
2500 |
|
- |
| Cl-6.2 (b) 6(Colour fastness to water spotting) |
- |
1500 |
|
- |
| Cl-6.2 (b) 7(Water vapour permeability) |
- |
1500 |
|
- |
| Cl-6.2 (b) 8(Colour fastness to water) |
- |
1500 |
|
- |
| Cl-7.1(General) |
- |
1000 |
|
- |
| Cl-7.2.1(Shelves) |
- |
2500 |
|
- |
| Cl-7.2.2(Tops and Bottoms) |
- |
2500 |
|
- |
| Cl-7.2.3(Strength of Clothes Rails and their Supports) |
- |
2500 |
|
- |
| Cl-7.2.4(Strength of the Structure) |
- |
2500 |
|
- |
| Cl-7.3.1(Pivoted Doors) |
- |
2500 |
|
- |
| Cl-7.3.2(Sliding Doors and Horizontal Roll-fronts) |
- |
2500 |
|
- |
| Cl-7.3.3(Flaps) |
- |
2500 |
|
- |
| Cl-7.3.4(Vertical Roll-Fronts) |
- |
2500 |
|
- |
| Cl-7.3.5(Extension Elements) |
- |
2500 |
|
- |
| Cl-7.3.6(Locking and Latching Mechanism Test) |
- |
2500 |
|
- |
| Cl-7.3.7(Pull Force Test) |
- |
2500 |
|
- |
| Cl-7.3.8(Top Load Ease Cycle Test) |
- |
2500 |
|
- |
| Cl-7.3.9(Durability Test for Units with Seating Surfaces – Cyclic Impact) |
- |
2500 |
|
- |
| Cl-7.3.10(Drop Test – Dynamic – for Units with Seat Surfaces) |
- |
2500 |
|
- |
| Cl-7.4.1(Units Not Supported by the Floor) |
- |
2500 |
|
- |
| Cl-7.4.2(Units Supported by the Floor) |
- |
2500 |
|
- |
| Cl-7.5.1(General) |
- |
2500 |
|
- |
| Cl-7.5.2(Doors, Extension Elements and Flaps Closed, All Storage Units Unloaded) |
- |
2500 |
|
- |
| Cl-7.5.3(Opening Doors, Extension Elements and Flaps, All Storage Units Unloaded) |
- |
2500 |
|
- |
| Cl-7.5.4(Doors, Extension Elements and Flaps Opened and Unlocked) |
- |
2500 |
|
- |
| Cl-7.5.5(Doors, Extension Elements and Flaps Closed and Locked, All Storage Units Loaded) |
- |
2500 |
|
- |
| Cl-7.5.6(Vertical Force Stability Test for Storage Units) |
- |
2500 |
|
- |
| Cl-7.5.7(Stability Test for Pedestals/Storage Units with Seat Surfaces) |
- |
2500 |
|
- |
| Cl-7.5.8(Dynamic Stability Test for Units with Castors) |
- |
2500 |
|
- |
| Cl-7.5.9(Strength Test for Wall Attachments) |
- |
2500 |
|
- |
| Cl-9(Marking) |
- |
0 |
|
- |
| CLAUSE 7.3.2(Sliding Doors and Horizontal Roll-fronts) |
- |
2500 |
|
- |
| CLAUSE 7.3.2.2(Slam shut/open test of sliding doors and horizontal roll-fronts) |
- |
2500 |
|
- |
| CLAUSE 7.3.2.3(Durability of sliding doors and horizontal roll-fronts) |
- |
2500 |
|
- |
| CLAUSE 7.3.3(Flaps) |
- |
2500 |
|
- |
| CLAUSE 7.3.3.1(Strength of bottom-hinged flaps) |
- |
2500 |
|
- |
| CLAUSE 7.3.3.2(Durability of flaps) |
- |
2500 |
|
- |
| CLAUSE 7.3.3.3(Drop test for top-hinged flaps) |
- |
2500 |
|
- |
| CLAUSE 7.3.4(Vertical Roll-Fronts) |
- |
2500 |
|
- |
| CLAUSE 7.3.4.1(Slam shut/open test of vertical roll-fronts) |
- |
2500 |
|
- |
| CLAUSE 7.3.4.2(Durability of vertical roll-fronts) |
- |
2500 |
|
- |
| CLAUSE 7.3.5(Extension Element) |
- |
2500 |
|
- |
| CLAUSE 7.3.5.2(Strength of extension elements) |
- |
2500 |
|
- |
| CLAUSE 7.3.5.3(Durability of extension elements) |
- |
2500 |
|
- |
| CLAUSE 7.3.5.4(Slam shut/open test of extension element) |
- |
2500 |
|
- |
| CLAUSE 7.3.5.5(Displacement of extension element bottoms) |
- |
2500 |
|
- |
| CLAUSE 7.3.5.6(Interlock test) |
- |
2500 |
|
- |
| CLAUSE 7.3.6(Locking and Latching Mechanism Tests) |
- |
2500 |
|
- |
| CLAUSE 7.3.6.2(Strength test for locking and latching mechanisms for extension elements) |
- |
2500 |
|
- |
| CLAUSE 7.3.6.3(Locking and latching mechanisms for doors, flaps and roll-fronts) |
- |
2500 |
|
- |
| CLAUSE 7.3.6.4(Durability test of locking and latching mechanisms) |
- |
2500 |
|
- |
| CLAUSE 7.3.7(Pull Force Test) |
- |
2500 |
|
- |
| CLAUSE 7.3.7(Pull Force Test) |
- |
2500 |
|
- |
| CLAUSE 7.3.8(Top Load Ease Cycle Test) |
- |
2500 |
|
- |
| CLAUSE 7.3.9(Durability Test for Units with Seating Surfaces – Cyclic Impact) |
- |
2500 |
|
- |
| CLAUSE 7.3.10("Drop Test – Dynamic – for Units with
Seat Surfaces") |
- |
2500 |
|
- |
| CLAUSE 7.4.1.3(Sustained load test (overload)) |
- |
2500 |
|
- |
| CLAUSE 7.4.1.4(Dislodgement test) |
- |
2500 |
|
- |
| CLAUSE 7.5(Stability Tests) |
- |
2500 |
|
- |
| CLAUSE 7.5.2.1("Units that can be adjusted to a Height of
1 000 mm or less") |
- |
2500 |
|
- |
| CLAUSE 7.5.2.2("Units that can be adjusted to a height of
more than 1 000 mm") |
- |
2500 |
|
- |
| CLAUSE 7.5.3(Opening Doors, Extension Elements and Flaps, All Storage Units Unloaded) |
- |
2500 |
|
- |
| CLAUSE 7.5.6(Vertical Force Stability Test for Storage Units) |
- |
2500 |
|
- |
| CLAUSE 7.5.7(Stability Test for Pedestals/Storage Units with Seat Surfaces) |
- |
2500 |
|
- |
| CLAUSE 7.5.8("Dynamic Stability Test for Units with
Castors") |
- |
2500 |
|
- |
| CLAUSE 7.5.9(Strength Test for Wall Attachments) |
- |
2500 |
|
- |
|
25 Feb, 2027 |
- - |
| 3778 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 9523 (2000) |
Ductile iron fittings for pressure pipes for water, gas and sewage - Specification (First Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 9(Tensile Test & Hardness Test) |
- |
2500 |
|
* 15,000 for complete testing upto and including 300 mm
* 20,000 for complete testing from 350 mm to 450 mm,
* 25,000 from 500 to 600 mm,
* 35,000 from 700 to 900 mm,
* 52,500 above 900 mm |
| Cl 10(Hydrostatic Test) |
- |
3500 |
|
* 15,000 for complete testing upto and including 300 mm
* 20,000 for complete testing from 350 mm to 450 mm,
* 25,000 from 500 to 600 mm,
* 35,000 from 700 to 900 mm,
* 52,500 above 900 mm |
| Cl 11(Nominal Diameter, Ovality, Dimensions, No. Of Holes & Bolt Sizes) |
- |
9000 |
|
* 15,000 for complete testing upto and including 300 mm
* 20,000 for complete testing from 350 mm to 450 mm,
* 25,000 from 500 to 600 mm,
* 35,000 from 700 to 900 mm,
* 52,500 above 900 mm |
| Cl 13(Coating) |
- |
9000 |
|
* 15,000 for complete testing upto and including 300 mm
* 20,000 for complete testing from 350 mm to 450 mm,
* 25,000 from 500 to 600 mm,
* 35,000 from 700 to 900 mm,
* 52,500 above 900 mm |
| Cl 6 & Table 4,5,6&7(Design & Tolerance) |
- |
9000 |
|
* 15,000 for complete testing upto and including 300 mm
* 20,000 for complete testing from 350 mm to 450 mm,
* 25,000 from 500 to 600 mm,
* 35,000 from 700 to 900 mm,
* 52,500 above 900 mm |
| Cl 6 & Table 4,5,6&7(Design & Tolerance) |
- |
9000 |
|
* 15,000 for complete testing upto and including 300 mm
* 20,000 for complete testing from 350 mm to 450 mm,
* 25,000 from 500 to 600 mm,
* 35,000 from 700 to 900 mm,
* 52,500 above 900 mm |
| Cl 9(Tensile Test & Hardness Test) |
- |
2500 |
|
* 15,000 for complete testing upto and including 300 mm
* 20,000 for complete testing from 350 mm to 450 mm,
* 25,000 from 500 to 600 mm,
* 35,000 from 700 to 900 mm,
* 52,500 above 900 mm |
| Cl 5(Thickness) |
- |
9000 |
|
* 15,000 for complete testing upto and including 300 mm
* 20,000 for complete testing from 350 mm to 450 mm,
* 25,000 from 500 to 600 mm,
* 35,000 from 700 to 900 mm,
* 52,500 above 900 mm |
|
- |
- - |
| 3779 |
Aaditech Test and Calibration Lab LLP
| 8179926
| IS 302 : Part 2 : SEC 31 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 31 range hoods |
Their rated voltage being not more than 250 V. |
48000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
2000 |
|
- |
| Clause No - 5.18(linear and angular dimension) |
- |
0 |
|
- |
| Clause No - 6.2(harmfull ingress of water) |
- |
1000 |
|
- |
| Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
2000 |
|
- |
| Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
0 |
|
- |
| Clause No - 8.2(Addition) |
- |
0 |
|
- |
| Clause No - 10.1, Table No. -1(power input deviation) |
- |
2000 |
|
- |
| Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
4000 |
|
- |
| Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
0 |
|
- |
| Clause No - 14(Impulse test voltage) |
- |
0 |
|
- |
| Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
3000 |
|
- |
| Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
5000 |
|
- |
| Clause No -19.11.4.1(electrostatic discharge) |
- |
0 |
|
- |
| Clause No -19.11.4.2(radiated field) |
- |
0 |
|
- |
| Clause No -19.11.4.3(fast transient) |
- |
0 |
|
- |
| Clause No -19.11.4.4(Voltage dips and interruption) |
- |
0 |
|
- |
| Clause No -21.1(Mechanical strength) |
- |
2000 |
|
- |
| Clause No -22.1(construction) |
- |
2000 |
|
- |
| Clause No -22.11(push force applied) |
- |
0 |
|
- |
| Clause No -24.1.2(safety isolating transformer) |
- |
0 |
|
- |
| Clause No -24.1.3(for switches) |
- |
0 |
|
- |
| Clause No -24.1.4(for automatic control) |
- |
0 |
|
- |
| Clause No -24.1.5(for innterconnection couplers) |
- |
0 |
|
- |
| Clause No -24.4(plug and socket) |
- |
0 |
|
- |
| Clause No -25.8, Table no -11(conductor resistance) |
- |
2000 |
|
- |
| Clause No -25.5(dimension for pins) |
- |
0 |
|
- |
| Clause No -27.6(for circuit board) |
- |
1000 |
|
- |
| Clause No -29.2(comparative tracking index) |
- |
1000 |
|
- |
| Clause No -29.3.3(dry heat test) |
- |
0 |
|
- |
| Clause No -30.2.1(glow wire test) |
- |
4000 |
|
- |
| Clause No -30.101("incorporate combustible
material") |
- |
0 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
0 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
0 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
2000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 22(CONSTRUCTION) |
- |
2000 |
|
- |
| 24(COMPONENTS) |
- |
2000 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR
HAZARDS) |
- |
0 |
|
- |
| 11(Heating) |
- |
5000 |
|
- |
| Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
| Clause No - 5.18(linear and angular dimension) |
- |
0 |
|
- |
| Clause No - 6.2(harmfull ingress of water) |
- |
0 |
|
- |
| Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
0 |
|
- |
| Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
0 |
|
- |
| Clause No - 8.2(Addition) |
- |
0 |
|
- |
| Clause No - 10.1, Table No. -1(power input deviation) |
- |
0 |
|
- |
| Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
0 |
|
- |
| Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
0 |
|
- |
| Clause No - 14(Impulse test voltage) |
- |
0 |
|
- |
| Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
0 |
|
- |
| Clause No -19.11.4.1(electrostatic discharge) |
- |
0 |
|
- |
| Clause No -19.11.4.2(radiated field) |
- |
0 |
|
- |
| Clause No -19.11.4.3(fast transient) |
- |
0 |
|
- |
| Clause No -19.11.4.4(Voltage dips and interruption) |
- |
0 |
|
- |
| Clause No -21.1(Mechanical strength) |
- |
0 |
|
- |
| Clause No -22.1(construction) |
- |
0 |
|
- |
| Clause No -22.11(push force applied) |
- |
0 |
|
- |
| Clause No -24.1.2(safety isolating transformer) |
- |
0 |
|
- |
| Clause No -24.1.3(for switches) |
- |
0 |
|
- |
| Clause No -24.1.4(for automatic control) |
- |
0 |
|
- |
| Clause No -24.1.5(for innterconnection couplers) |
- |
0 |
|
- |
| Clause No -24.4(plug and socket) |
- |
0 |
|
- |
| Clause No -25.8, Table no -11(conductor resistance) |
- |
0 |
|
- |
| Clause No -25.5(dimension for pins) |
- |
0 |
|
- |
| Clause No -27.6(for circuit board) |
- |
0 |
|
- |
| Clause No -29.2(comparative tracking index) |
- |
0 |
|
- |
| Clause No -29.3.3(dry heat test) |
- |
0 |
|
- |
| Clause No -30.2.1(glow wire test) |
- |
0 |
|
- |
| Clause No -30.101("incorporate combustible
material") |
- |
0 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
0 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
0 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
0 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 22(CONSTRUCTION) |
- |
0 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR
HAZARDS) |
- |
0 |
|
- |
| 11(Heating) |
- |
0 |
|
- |
| Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
| Clause No - 5.18(linear and angular dimension) |
- |
0 |
|
- |
| Clause No - 6.2(harmfull ingress of water) |
- |
0 |
|
- |
| Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
0 |
|
- |
| Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
0 |
|
- |
| Clause No - 8.2(Addition) |
- |
0 |
|
- |
| Clause No - 10.1, Table No. -1(power input deviation) |
- |
0 |
|
- |
| Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
0 |
|
- |
| Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
0 |
|
- |
| Clause No - 14(Impulse test voltage) |
- |
0 |
|
- |
| Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
0 |
|
- |
| Clause No -19.11.4.1(electrostatic discharge) |
- |
0 |
|
- |
| Clause No -19.11.4.2(radiated field) |
- |
0 |
|
- |
| Clause No -19.11.4.3(fast transient) |
- |
0 |
|
- |
| Clause No -19.11.4.4(Voltage dips and interruption) |
- |
0 |
|
- |
| Clause No -21.1(Mechanical strength) |
- |
0 |
|
- |
| Clause No -22.1(construction) |
- |
0 |
|
- |
| Clause No -22.11(push force applied) |
- |
0 |
|
- |
| Clause No -24.1.2(safety isolating transformer) |
- |
0 |
|
- |
| Clause No -24.1.3(for switches) |
- |
0 |
|
- |
| Clause No -24.1.4(for automatic control) |
- |
0 |
|
- |
| Clause No -24.1.5(for innterconnection couplers) |
- |
0 |
|
- |
| Clause No -24.4(plug and socket) |
- |
0 |
|
- |
| Clause No -25.8, Table no -11(conductor resistance) |
- |
0 |
|
- |
| Clause No -25.5(dimension for pins) |
- |
0 |
|
- |
| Clause No -27.6(for circuit board) |
- |
0 |
|
- |
| Clause No -29.2(comparative tracking index) |
- |
0 |
|
- |
| Clause No -29.3.3(dry heat test) |
- |
0 |
|
- |
| Clause No -30.2.1(glow wire test) |
- |
0 |
|
- |
| Clause No -30.101("incorporate combustible
material") |
- |
0 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
0 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
0 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
0 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 22(CONSTRUCTION) |
- |
0 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR
HAZARDS) |
- |
0 |
|
- |
| 11(Heating) |
- |
0 |
|
- |
| Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
| Clause No - 5.18(linear and angular dimension) |
- |
0 |
|
- |
| Clause No - 6.2(harmfull ingress of water) |
- |
0 |
|
- |
| Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
0 |
|
- |
| Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
0 |
|
- |
| Clause No - 8.2(Addition) |
- |
0 |
|
- |
| Clause No - 10.1, Table No. -1(power input deviation) |
- |
0 |
|
- |
| Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
0 |
|
- |
| Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
0 |
|
- |
| Clause No - 14(Impulse test voltage) |
- |
0 |
|
- |
| Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
0 |
|
- |
| Clause No -19.11.4.1(electrostatic discharge) |
- |
0 |
|
- |
| Clause No -19.11.4.2(radiated field) |
- |
0 |
|
- |
| Clause No -19.11.4.3(fast transient) |
- |
0 |
|
- |
| Clause No -19.11.4.4(Voltage dips and interruption) |
- |
0 |
|
- |
| Clause No -21.1(Mechanical strength) |
- |
0 |
|
- |
| Clause No -22.1(construction) |
- |
0 |
|
- |
| Clause No -22.11(push force applied) |
- |
0 |
|
- |
| Clause No -24.1.2(safety isolating transformer) |
- |
0 |
|
- |
| Clause No -24.1.3(for switches) |
- |
0 |
|
- |
| Clause No -24.1.4(for automatic control) |
- |
0 |
|
- |
| Clause No -24.1.5(for innterconnection couplers) |
- |
0 |
|
- |
| Clause No -24.4(plug and socket) |
- |
0 |
|
- |
| Clause No -25.8, Table no -11(conductor resistance) |
- |
0 |
|
- |
| Clause No -25.5(dimension for pins) |
- |
0 |
|
- |
| Clause No -27.6(for circuit board) |
- |
0 |
|
- |
| Clause No -29.2(comparative tracking index) |
- |
0 |
|
- |
| Clause No -29.3.3(dry heat test) |
- |
0 |
|
- |
| Clause No -30.2.1(glow wire test) |
- |
0 |
|
- |
| Clause No -30.101("incorporate combustible
material") |
- |
0 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
0 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
0 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
0 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 22(CONSTRUCTION) |
- |
0 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR
HAZARDS) |
- |
0 |
|
- |
| 11(Heating) |
- |
0 |
|
- |
| Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
| Clause No - 5.18(linear and angular dimension) |
- |
0 |
|
- |
| Clause No - 6.2(harmfull ingress of water) |
- |
0 |
|
- |
| Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
0 |
|
- |
| Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
0 |
|
- |
| Clause No - 8.2(Addition) |
- |
0 |
|
- |
| Clause No - 10.1, Table No. -1(power input deviation) |
- |
0 |
|
- |
| Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
0 |
|
- |
| Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
0 |
|
- |
| Clause No - 14(Impulse test voltage) |
- |
0 |
|
- |
| Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
0 |
|
- |
| Clause No -19.11.4.1(electrostatic discharge) |
- |
0 |
|
- |
| Clause No -19.11.4.2(radiated field) |
- |
0 |
|
- |
| Clause No -19.11.4.3(fast transient) |
- |
0 |
|
- |
| Clause No -19.11.4.4(Voltage dips and interruption) |
- |
0 |
|
- |
| Clause No -21.1(Mechanical strength) |
- |
0 |
|
- |
| Clause No -22.1(construction) |
- |
0 |
|
- |
| Clause No -22.11(push force applied) |
- |
0 |
|
- |
| Clause No -24.1.2(safety isolating transformer) |
- |
0 |
|
- |
| Clause No -24.1.3(for switches) |
- |
0 |
|
- |
| Clause No -24.1.4(for automatic control) |
- |
0 |
|
- |
| Clause No -24.1.5(for innterconnection couplers) |
- |
0 |
|
- |
| Clause No -24.4(plug and socket) |
- |
0 |
|
- |
| Clause No -25.8, Table no -11(conductor resistance) |
- |
0 |
|
- |
| Clause No -25.5(dimension for pins) |
- |
0 |
|
- |
| Clause No -27.6(for circuit board) |
- |
0 |
|
- |
| Clause No -29.2(comparative tracking index) |
- |
0 |
|
- |
| Clause No -29.3.3(dry heat test) |
- |
0 |
|
- |
| Clause No -30.2.1(glow wire test) |
- |
0 |
|
- |
| Clause No -30.101("incorporate combustible
material") |
- |
0 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
0 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
0 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
0 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 22(CONSTRUCTION) |
- |
0 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR
HAZARDS) |
- |
0 |
|
- |
| 11(Heating) |
- |
0 |
|
- |
| Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
| Clause No - 5.18(linear and angular dimension) |
- |
0 |
|
- |
| Clause No - 6.2(harmfull ingress of water) |
- |
0 |
|
- |
| Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
0 |
|
- |
| Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
0 |
|
- |
| Clause No - 8.2(Addition) |
- |
0 |
|
- |
| Clause No - 10.1, Table No. -1(power input deviation) |
- |
0 |
|
- |
| Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
0 |
|
- |
| Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
0 |
|
- |
| Clause No - 14(Impulse test voltage) |
- |
0 |
|
- |
| Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
0 |
|
- |
| Clause No -19.11.4.1(electrostatic discharge) |
- |
0 |
|
- |
| Clause No -19.11.4.2(radiated field) |
- |
0 |
|
- |
| Clause No -19.11.4.3(fast transient) |
- |
0 |
|
- |
| Clause No -19.11.4.4(Voltage dips and interruption) |
- |
0 |
|
- |
| Clause No -21.1(Mechanical strength) |
- |
0 |
|
- |
| Clause No -22.1(construction) |
- |
0 |
|
- |
| Clause No -22.11(push force applied) |
- |
0 |
|
- |
| Clause No -24.1.2(safety isolating transformer) |
- |
0 |
|
- |
| Clause No -24.1.3(for switches) |
- |
0 |
|
- |
| Clause No -24.1.4(for automatic control) |
- |
0 |
|
- |
| Clause No -24.1.5(for innterconnection couplers) |
- |
0 |
|
- |
| Clause No -24.4(plug and socket) |
- |
0 |
|
- |
| Clause No -25.8, Table no -11(conductor resistance) |
- |
0 |
|
- |
| Clause No -25.5(dimension for pins) |
- |
0 |
|
- |
| Clause No -27.6(for circuit board) |
- |
0 |
|
- |
| Clause No -29.2(comparative tracking index) |
- |
0 |
|
- |
| Clause No -29.3.3(dry heat test) |
- |
0 |
|
- |
| Clause No -30.2.1(glow wire test) |
- |
0 |
|
- |
| Clause No -30.101("incorporate combustible
material") |
- |
0 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
0 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
0 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
0 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 22(CONSTRUCTION) |
- |
0 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR
HAZARDS) |
- |
0 |
|
- |
| 11(Heating) |
- |
0 |
|
- |
| Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
| Clause No - 5.18(linear and angular dimension) |
- |
0 |
|
- |
| Clause No - 6.2(harmfull ingress of water) |
- |
0 |
|
- |
| Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
0 |
|
- |
| Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
0 |
|
- |
| Clause No - 8.2(Addition) |
- |
0 |
|
- |
| Clause No - 10.1, Table No. -1(power input deviation) |
- |
0 |
|
- |
| Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
0 |
|
- |
| Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
0 |
|
- |
| Clause No - 14(Impulse test voltage) |
- |
0 |
|
- |
| Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
0 |
|
- |
| Clause No -19.11.4.1(electrostatic discharge) |
- |
0 |
|
- |
| Clause No -19.11.4.2(radiated field) |
- |
0 |
|
- |
| Clause No -19.11.4.3(fast transient) |
- |
0 |
|
- |
| Clause No -19.11.4.4(Voltage dips and interruption) |
- |
0 |
|
- |
| Clause No -21.1(Mechanical strength) |
- |
0 |
|
- |
| Clause No -22.1(construction) |
- |
0 |
|
- |
| Clause No -22.11(push force applied) |
- |
0 |
|
- |
| Clause No -24.1.2(safety isolating transformer) |
- |
0 |
|
- |
| Clause No -24.1.3(for switches) |
- |
0 |
|
- |
| Clause No -24.1.4(for automatic control) |
- |
0 |
|
- |
| Clause No -24.1.5(for innterconnection couplers) |
- |
0 |
|
- |
| Clause No -24.4(plug and socket) |
- |
0 |
|
- |
| Clause No -25.8, Table no -11(conductor resistance) |
- |
0 |
|
- |
| Clause No -25.5(dimension for pins) |
- |
0 |
|
- |
| Clause No -27.6(for circuit board) |
- |
0 |
|
- |
| Clause No -29.2(comparative tracking index) |
- |
0 |
|
- |
| Clause No -29.3.3(dry heat test) |
- |
0 |
|
- |
| Clause No -30.2.1(glow wire test) |
- |
0 |
|
- |
| Clause No -30.101("incorporate combustible
material") |
- |
0 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
0 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
0 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
0 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 22(CONSTRUCTION) |
- |
0 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR
HAZARDS) |
- |
0 |
|
- |
| 11(Heating) |
- |
0 |
|
- |
|
- |
- Included w.e.f 15.10.2025
Exclusion:Cl 19.11.4.1-19.11.4.7, Cl 32 (RADIATION, TOXICITY AND SIMILAR HAZARDS), Cl 24 (COMPONENTS) |
| 3780 |
ARYAVRAT TEST HOUSE PRIVATE LIMITED
| 5191706
| IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
Crosslinked Polyethylene IArmoured/Unarmoured with Aluminium/Copper Conductor , Class 1/2, Category 01/C1/C2 , except/suitable for use in Mines , excluding/including Low Temp. application for working Volt. up to and including 1100V |
3200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(CONDUCTOR: MATERIALS) |
- |
100 |
|
- |
| 4(INSULATION : MATERIALS) |
- |
100 |
|
- |
| 5.1(FILLER AND INNER SHEATH) |
- |
100 |
|
- |
| 5.2(FILLER AND INNER SHEATH) |
- |
100 |
|
- |
| 6(ARMOURING) |
- |
100 |
|
- |
| 7(OUTER SHEATH) |
- |
100 |
|
- |
| 8.1(CONDUCTOR: CONSTRUCTION) |
- |
100 |
|
- |
| 8.2(PROTECTIVE BARRIER) |
- |
100 |
|
- |
| 8.3(SIZE OF NEUTRAL CONDUCTOR) |
- |
100 |
|
- |
| 9.1(Insulation Applied by extrusicn) |
- |
100 |
|
- |
| 9.2(Thickness of Insulation - Average) |
- |
100 |
|
- |
| 9.3(Thickness of Insulation - Minimum) |
- |
200 |
|
- |
| 9.4(Application of Insulation) |
- |
100 |
|
- |
| 10.1(Core Identification) |
- |
100 |
|
- |
| 10.2(Core Identification- Neutral) |
- |
100 |
|
- |
| 10.3(Core Identification by number ) |
- |
100 |
|
- |
| 10.4(Core Identification by number - Neutral ) |
- |
100 |
|
- |
| 11(LAVING UP OF CORES) |
- |
100 |
|
- |
| 12.1 & 12.2(Inner sheath : Application) |
- |
100 |
|
- |
| 12.3(Thickness of Inner Sheath) |
- |
100 |
|
- |
| 13.1(Armouring: Application) |
- |
100 |
|
- |
| 13.1.2(Armouring: Coverage ) |
- |
300 |
|
- |
| 13.1.3(Armouring: Direction of Lay ) |
- |
100 |
|
- |
| 13.2(Type of armour ) |
- |
100 |
|
- |
| 13.3(Armouring : Dimensions -Wire Diameter) |
- |
200 |
|
- |
| 13.3(Armouring : Dimensions -Formed wire ) |
- |
200 |
|
- |
| 13.4(Armour: Joint) |
- |
100 |
|
- |
| 13.5(Armouring : Resistance Test) |
- |
500 |
|
- |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
300 |
|
- |
| 13.6 b)(ARMOURING: Elongation ) |
- |
200 |
|
- |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
200 |
|
- |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
200 |
|
- |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
500 |
|
- |
| Cl.13.5.1 and Table 7(Resistance Test for Armouring (other than mining Cables)) |
- |
500 |
|
- |
| Cl.15.4(Cold Impact Test (For outer sheath)) |
- |
500 |
|
- |
| Cl.15.4(Cold Bend Test (for outer sheath)) |
- |
500 |
|
- |
| Cl.8(Conductor) |
- |
100 |
|
- |
| Cl.8(Conductor) |
- |
100 |
|
- |
| Cl.8(Conductor) |
- |
100 |
|
- |
| Cl 16(Halogen Acid Gas Test) |
- |
2500 |
|
- |
| Cl 16(Halogen Acid Gas Test) |
- |
2500 |
|
- |
| Cl 16(Halogen Acid Gas Test) |
- |
2500 |
|
- |
| Table 2(Cold bend test for Outer sheath) |
- |
500 |
|
- |
| Table 2(Cold Impact test for Outer sheath) |
- |
500 |
|
- |
| Cl No. 16.15(Smoke density test) |
- |
2500 |
|
- |
| Table 4(Copper purity test) |
- |
2000 |
|
- |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
500 |
|
- |
| 13.6 g)(ARMOURING: Resistivity) |
- |
500 |
|
- |
| Table 1(Ageing in air oven - Elongation on Insulation) |
- |
1000 |
|
- |
| Table 1(Ageing in air oven - Tensile strength on Insulation) |
- |
1000 |
|
- |
| Table 1(Ageing in air oven - Elongation on Insulation) |
- |
1000 |
|
- |
| 15.4 (b)(Cold impact) |
- |
500 |
|
- |
| 15.4 (a)(Cold bend) |
- |
500 |
|
- |
| 17.3(cable Code ) |
- |
100 |
|
- |
| 17.2(cable Indentification ) |
- |
100 |
|
- |
| 17.1(Manufacturer'. identification) |
- |
100 |
|
- |
| 16.14(Temperature Index) |
- |
2500 |
|
- |
| 16.13(Test for Halogen Acid Gas Evolution) |
- |
2500 |
|
- |
| 16.9(Oxygen Index Test) |
- |
2500 |
|
- |
| 16.3(FLAMMABILITY TEST : Unaffected length ) |
- |
250 |
|
- |
| 16.3(FLAMMABILITY TEST : Period of Burning ) |
- |
250 |
|
- |
| 16.2(HIGH VOLTAGE TEST ) |
- |
500 |
|
- |
| Table 1(Ageing in air oven - Tensile strength on Insulation) |
- |
1000 |
|
- |
| 14.1(Outer Sheath : Application) |
- |
100 |
|
- |
| 14.2(Colour of outer sheath) |
- |
100 |
|
- |
| 14.3(Thickness of outer sheath - AVERAGE) |
- |
200 |
|
- |
| 14.3(Thickness of outer sheath - minimum) |
- |
200 |
|
- |
| 15.1 a) i)(Annealing Test ( For copper wire ) ) |
- |
300 |
|
- |
| 15.1 a) ii)(Tensile test (for aluminium) - Before stranding ) |
- |
500 |
|
- |
| 15.1 a) ii)(Tensile test (for aluminium) - After stranding ) |
- |
500 |
|
- |
| 15.1 a) iii)(Wrapping test (for aluminium)) |
- |
200 |
|
- |
| 15.1 a) iv)(Resistance test - Main conductor) |
- |
500 |
|
- |
| 15.1 a) iv)(Resistance test - Neutral conductor) |
- |
500 |
|
- |
| 15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
300 |
|
- |
| 15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
200 |
|
- |
| 15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
1000 |
|
- |
| 15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
1000 |
|
- |
| 15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
500 |
|
- |
| 15.1 d) iii) (Phyaical tests for insulation : Permanent set ) |
- |
300 |
|
- |
| 15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
500 |
|
- |
| 15.1 d) iv) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
500 |
|
- |
| 15.1 d) v) (Insulation: Waterabsorption(gravimetric)) |
- |
1500 |
|
- |
| 15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
300 |
|
- |
| 15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
200 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
1000 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
100 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
1000 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
1000 |
|
- |
| 15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
1000 |
|
- |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
500 |
|
- |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
500 |
|
- |
| 15.1 e) v) (Sheath : Hot deformation) |
- |
500 |
|
- |
| 15.1 f)(INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
1000 |
|
- |
| 15.1 e) vi) (Sheath : Heat shock test) |
- |
500 |
|
- |
| 15.1 e) vii) (Sheath : Thermalstability) |
- |
300 |
|
- |
| 16.1(Flame Retardance Test on Single Cables) |
- |
1000 |
|
- |
|
28 Nov, 2028 |
- - |